View Bid Results For Energy Efficiency Project Tenders

We found 116 Bid Results related to energy efficiency project tenders. You can find Contractor details who won energy efficiency project tenders along with contract details in Bid awards announcements section.

Filters
Stage
90
17
9
Tender Publishing Platform
12
104
State / UT
22
32
13
10
7
6
6
6
5
5
4
4
3
3
3
2
1
1
1
1
1
1
1
Contract Value
27
24
40
24
Publish Date
0
0
0
0
0
Sector
17
20
20
19
18
8
5
5
4
4
2
2
2
2
2
1
1
1
Ownership
5
61
24
18
12
1
Within keyword
Active filters:
Showing 1–3 of 116 tenders matching your filters
1.
Tourism #11266721 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
4.
Civil Aviation #11142964 AOC
Tender For Supply, Installation, Testing & Commissioning Of 350 Tr Horizontal Twin Screw Type Water-Cooled Chiller: Factory-Assembled Water-Cooled Chiller Unit Consisting Of A Semi-Hermetic Twin Screw Compressor Directly Coupled To An Energy-Efficient Minimum Ie4 Motor, Vfd-Driven With Active Harmonics Filter, Suitable For 3-Phase, 50 Hz Power Supply. The Chiller Shall Be Complete With A Shell And Tube Flooded/Falling Film Evaporator And A Water-Cooled Shell And Tube Condenser. Chiller Evaporator And Condenser Shall Have Even Pass Connections To Suit The Existing Plant Room Layout. Refrigerant Used Shall Be R-513A/R-134A, Factory Charged With Refrigerant And Oil. The Unit Shall Be Mounted On A Rigid, Fabricated Steel Frame With Anti-Vibration Isolators And An Inertia Base Suitable For Indoor Installation. The Chiller Shall Have A Maximum Sound Level Of 85 Db(A) Measured At A Distance Of 1 Meter From The Unit Under All Operating Conditions. Chiller Evaporator And Condenser Shall Be Asme Certified And U-Stamped. The Chiller Shall Be Complete With Flow Switches, Temperature Sensors, Internal Refrigerant Piping, Power And Control Wiring, And 38 Mm Thick Nitrile Rubber Insulation. The Control System Shall Be Microprocessor-Based With Lcd/Touchscreen Hmi, Supporting Full Automation, Real-Time Monitoring, Diagnostics, Alarm History And Data Logging. The Chiller Shall Support Native Bacnet/Ip Communication Protocol For Seamless Integration With The Building Management System. The Unit Shall Include All Required Safety Protections Such As High And Low Pressure Cut-Outs, Anti-Freeze Protection, Oil Pressure Monitoring, Motor Current Protection, Overload Protection, Single-Phase Preventer, Phase Reversal Protection, Earth Fault Trip And Vfd Protections. Design Conditions Shall Be: Chilled Water Inlet 55°F, Chilled Water Outlet 45°F, And Condenser Water Inlet 90°F And Condenser Water Outlet 100°F. Performance Requirements Shall Be 350 Tr Capacity With A Chilled Water Flow Rate Of 840 Gpm And A Condenser Water Flow Rate Of 1050 Gpm. At Ahri 550/590 Standard Rating Conditions, The Chiller Shall Have A Cop ≥ 6.2 (≤ 0.567 Kw/Tr) And An Iplv ≥ 8.1 (≤ 0.434 Kw/Tr). The Iseer Shall Be ≥ 7.9, Meeting Bee 4 Star Rating Or Above. At The Specified Project Design Conditions, The Chiller Shall Have A Cop ≥ 5.2 (≤ 0.676 Kw/Tr) And An Nplv ≥ 5.8 (≤ 0.606 Kw/Tr). Fouling Factors Shall Be 0.0005 Ft²·°F·Hr/Btu For The Evaporator And 0.001 Ft²·°F·Hr/Btu For The Condenser. The Chiller Shall Be Ahri Certified In Accordance With Ahri Standard 550/590 (I-P). All Civil Works Related To Reinforced Cement Concrete Foundation, Vibration Isolators, Grouting And Alignment Of The Chiller Shall Be Under The Contractors Scope. All Electrical Works, Including Supply And Installation Of Cable From The Nearest Panel To The Chiller Vfd, Termination, Earthing And Necessary Adapters For Cu/Al Cables, Shall Be Under The Contractors Scope. The Installation Shall Comply With Kerala Electrical Inspectorate Rules And Applicable Statutory Regulations. , Supply Installation Testing And Commissioning Of End Suction Top Discharge Centrifugal Pump-Set For Rated Continuousduty And Efficiency, With Necessary, Y-D Starter Placed Inside The Existing Panel If Possible, Power & Control Cabling From Starter Panel To Equipment Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, Suitable Adapter Box If Required And Earthing Of Pump, Power Cable, Bronze Impeller, Common Base Frame & Necessary, Motor, Coupling, Inertial Bases (Pedestal), Andvibration Isolators, Mechanical Seal For Recirculation Of Chilled Water. The Pumpmotor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Pump Set Shall Be Complete In All Respects As Required By The Standard Specification And Shall Suit The Following Minimum Capacities: Primary Water Pump Set Of Capacity 840 Gpm At 18M Of Wg Head , Supply Installation Testing And Commissioning Of Horizontal Split Case Centrifugal Pump-Set For Rated Continuous Duty And Efficiency, Complete With Supply And Installation Of Vfd, Along With On/Off Push Button For Local Isolation As Per Ksei Regulation Earthing, Along With Required Control Cabling, Motor, Bronze Impeller, Common Base Frame, Coupling, Inertia Bases And Vibration Isolators, Earthing Of Pump, Power Cable, And Mechanical Seal For Recirculation Of Chilled Water. The Pump Motor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Motor Speed Not To Exceed 1450 Rpm/2900Rpm. Pump Set Shall Be Complete In All Respects As Per The Technical Specifications And Shall Suit The Following Capacities: Secondary Water Pump Set Of Capacity 900 Gpm At 50 M Of Wg Head Note: Existing Power Cable From Vfd To The Pump Can Be Used , Supply Installation Testing And Commissioning Of Horizontal Split Case Centrifugal Pump-Set For Rated Continuous Duty And Efficiency, With Necessary Y-D Starter Placed Inside The Existing Panel If Possible, Power & Control Cabling From Starter Panel To Equipment Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, Suitable Adapter Box If Required, Earthing Of Pump, Power Cable, And Bronze Impeller, Common Base Frame & Necessary, Motor Coupling, Inertia Bases And Vibration Isolators, Mechanical Seal For Recirculation Of Chilled Water. The Pump Motor Shall Be Energy Efficient To Ie 3, Be Suitable For 415 + 10% Volts, 50 Cycles, 3 Phase, Tefc & Class F Insulation. Pump Set Shall Be Complete In All Respects As Per The Technical Specifications And Shall Suit The Following Capacities- Condenser Water Pump Set Of Capacity 1050 Gpm At 30 M Of Wg Head , Supply Installation Testing And Commissioning Of Frp Vertical Induced Draft Counter/Cross Flow Type Single Cell Cooling Towers (Cti Certified) Complete With Frp Basin, Frp Body, Vfd Compatible Ip55 Motor Fan, Motor Shall Be Min Ie3, Tefc And Class F Insulation, Fill Media, Distribution Basin Pipe Connections, With Drift Eliminator, Ladder, Supply And Installation Of Y-D Starter In The Existing Panel, Suitably Rated Cabling From Starter Panel To Cooling Tower Along With On/Off Push Button For Local Isolation As Per Ksei Regulation, All Nuts And Bolts Of Ss316, Plain Cement Concrete /Rcc Foundation As Required Etc. And The Equipment Shall Be Compatible Withbacnet/ Ip Complete In All Respects As Per The Technical Specifications. The Noise Level From The Cooling Tower Shall Be Less Than 68 Db(A) At A 10-Meter Distance From The Air Inlet Side Of The Cooling Tower. Delta T - 10 °F Approach Less Than- 5 °F Fan Efficiency Less Than - 0.35Kw/L/S Wet Bulb Temperature- 83 Deg F Water Flow Rate-1050 Usgpm , Supply, Installation, Testing And Commissioning Of Condenser Water Piping Of 250 Mm Dia Pipes Of Minimum 1.2Mm Thickness Frp Coated Ms C Class Heavy Duty Pipes Laid Between Cooling Tower Pumps ,Condenser Shells And Cooling Tower Complete With All Fittings And Accessories Like Bends, Tees, Reducers, Supports, Clamps, Etc, Pipes Shall Be Applied With Bituminous Primer And Painted To Colour Codes. The Item Shall Be Complete In All Respects As Per Technical Specifications. Note : The Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From A Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. , Supply, Installation, Testing And Commissioning Of 200Mm Dia Pipes, 50Mm Puf Insulation With Hdpe Jacket Of 2Mm Thickness Factory Fabricated, Of Ms C Class Heavy Duty Pipes Complete With All Fittings And Accessories Like Bends, Tees, Reducers, Expansion Joints, Rubber Support Inserts, Clamps, Insulated With 50 Mm Thick Puf Insulation Of 36 Kg/M3 Density Confirming To Standard Specification And Repairing Of Damage To Building Etc. The Item Shall Be Complete In All Respects As Per The Technical Specifications , Supply Installation Testing And Commissioning Of 250 Mm Dia Ci Wafer/Lug Type Butterfly Valves In Condenser Water Lines, Complete In All Respects As Per Technical Specifications. The Material Of Butterfly Valves Shall Be As Body- Cast Iron, Disc- Cast Bronze Or Stainless Steel, Seat-Epdm Rubber, O-Ring-Epdm. All Butterfly Valves Shall Be Designed, Manufactured, And Tested Strictly In Accordance With Is 13095:2020 - Butterfly Valves For General Purposes. , Supply Installation Testing And Commissioning Of 200 Mm Dia Ci Wafer/Lug Type Butterfly Valves In Condenser Water Lines, Complete In All Respects As Per Technical Specifications. The Material Of Butterfly Valves Shall Be As Body- Cast Iron, Disc- Cast Bronze Or Stainless Steel, Seat-Epdm Rubber, O-Ring- Epdm. All Butterfly Valves Shall Be Designed, Manufactured, And Tested Strictly In Accordance With Is 13095:2020 - Butterfly Valves For General Purposes. , Supply Installation Testing And Commissioning Of 250 Mm Epdm Rubber Flexible Connectors (Expansion Bellows) In Condenser Water Lines, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Epdm Rubber Flexible Connectors (Expansion Bellows) In Chilled Water Lines, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 250 Mm Dia Ci Dual Plate, Wafer-Type, Spring-Loaded Non-Return Valves In Condenser Water Lines. Complete In All Respects As Per The Technical Specifications. The Valve Shall Be Of Bronze Or Gun Metal, The Body Being Of Cast Iron; Flanged Ends Shall Be Provided. , Supply Installation Testing And Commissioning Of 200 Mm Dia Ci Dual Plate, Wafer-Type, Spring-Loaded Non-Return Valves In Condenser Water Lines. Complete In All Respects As Per The Technical Specifications. The Valve Shall Be Of Bronze Or Gun Metal, The Body Being Of Cast Iron; Flanged Ends Shall Be Provided. , Supply Installation Testing And Commissioning Of 250 Mm Dia Y-Strainer Cast Iron Body, And Ss 304 Strainer In Condenser Water Piping, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Dia Y-Strainer Cast Iron Body, And Ss 304 Strainer In Chilled Water Lines, Duly Insulated In The Same Manner And Same Thickness As Chilled Water Piping, Complete In All Respects As Per Technical Specifications , Supply Installation Testing And Commissioning Of 200 Mm Dia Manual Double Regulating Balancing Valve (Drv), Flanged Pn16 Construction, Cast Iron Body With Epdm-Coated Sg Iron Disc. Valve Shall Include Built-In Pressure Test Cocks With Extended Lengths For Insulation. Balancing Valves In Chilled Water Lines, Duly Insulated In The Same Manner And Same Thickness As Chilled Water Piping, Complete In All Respects As Per Technical Specifications. , Supply Installation Testing And Commissioning Of Bourdon Type Pressure Gauge, 100Mm Dial, Glycerine Filled. Case Made Of Ss 304. Range: 0-10 Bar. Complete With Ss 316 U Type Siphon And A Heavy-Duty Forged Brass/Ss Service Cock , Supply Installation Testing And Commissioning Of Stem-Type Thermometers Complete In All Respects As Per Technical Specifications. , Dismantling And Buyback , Dismantling And Buyback Of 200Tr Chiller (Including Concrete Pedestals) , Dismantling And Buyback Of 100Tr Chiller (Including Concrete Pedestals) , Dismantling And Buyback Of 200Tr Cooling Towers (Including Concrete Pedestals) , Dismantling And Buyback Of 100 Tr Cooling Towers (Including Concrete Pedestals) , Dismantling And Buyback Of Primary Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Secondary Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Condenser Pumps (Including Concrete Pedestals) , Dismantling And Buyback Of Condenser Water Lines , Dismantling And Buyback Of Chilled Water Lines With Insulation , Camc For The Chiller Through Oem Only, 1St Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 2Nd Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 3Rd Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 4Th Year After 2-Year Dlp , Camc For The Chiller Through Oem Only, 5Th Year After 2-Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 1St Year After 2-Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller,2Nd Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 3Rd Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 4Th Year After 2 Year Dlp , Camc For Equipment Executed Under This Contract, Other Than The Chiller, 5Th Year After 2-Year Dlp
Contract Date: May 22, 2026 Contract Value : 2.01 Crore
Boards / Undertakings / PSU No of Bidders 2
5.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
6.
Tourism #11099606 AOC
Tender For Civil Works , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directedwithin A Lead Of 50M.All Kinds Of Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-20 Grade Of Concrete , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Electrical Work , Supply Of 6M Decorative Single Arm Cameroon Pole With 72W Sabik Ø480mm Crown Tm Pc:- 6M Height Designer Decorative Single Arm Pole Made In Combination Of Steel Pipe Which Is Fabricated Using 114 Mm(+/-3%)Dia Grooved Pipe X 4Mm Thick Base Section With Minimum Height Of 2000Mm. The Pole Is To Be Provided With A Surface Mounting Suitable Base Plate Dia Of 350 Mm And Suitable Thickness As Per Is Standards And Structural Reports. Decorative Knob On The Top Is Made Of Cast Aluminium In Single Piece Of Minimum Height 360Mm. The Pole Should Be Provided With An Inbuilt Junction Box To Fix Four-Way Connector And 6A Mcb At The Bottom - The Inbuilt Box Should Have A Flush Door Of Suitable Size. The Decorative Pedestal To Be Mounted On A Suitable Size Steel Plate. The Pole Shall Be Hot Dip Galvanized. . The Suitable Size Foundation Bolt Shall Be Supply Along With The Pole Of En 8 Grade. The Manufacturer Needs To Provide A Structural Analysis For Structural Stability Of The Pole With The Relevant Is Standards Is 1239/1161/E250 Needs To Be Clearly Mentioned. The Same Needs To Be Confirmed In Form Of Test Certificates From The Manufacturer. Internal Wiring Backelite Sheet And Mcb Included Please Refer The Attached Drawing No - Cameroon 6M Sa Tm Pole. Including 72W Post Top Fixture Suitable To Mount 72W ± 10% With Mcpcb Of Not Less Than 1.6 Mm Thickness And Cu Of 35 Microns And 2.5 Thermal Conductivity For Fixture. The Led Used Should Be High Power Epoxy Leds (Make- Osram/Bridgelux/Nichia/Cree) With Macadam /= 5 And Cri /= 70 And Cct 4000K. The Luminaire Should Have System Efficacy (Lumens/Watt) 110 Lumens/Watt. The Luminaire Should Be Having A Warranty For A Period Of 5 Years Against Any Manufacturing Defects. The Manufacturer Should Have Internal Testing Equipments Especially 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturer Shall Submit The Lm 80 Report For Led Used In The Fixtures. Similar To Model No. Sabik Ø480mm Crown Tm Pc Clear Sl. The Luminaire Should Be Rohs Compliant As Per Government Notification And With A Valid Bis Number. Luminaire Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Street Light Panel: Supply Installation Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 63A Tpn Mcb As Incommer And 11 Nos Of 16 A Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based 25 A Programmable Digital Almac Timer As Directed By Engineer In-Charge. , Supply Of High Quality Static White (3000K) Linear Wall Washer In 1000Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 36W And System Lumen Output Of Not Less Than 2910 Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make: Reytek, Leksa, La-Lumirie,Phillips,Havells As Directed By The Engineer Incharge. , Supply Of High Quality Static White (3000K) Linear Wall Washer In 1000Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 18W And System Lumen Output Of Not Less Than 1490 Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Linear Wall Washer In 500Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 12W And System Lumen Output Of Not Less Than 980 Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make: Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Floodlight Projector Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Pressure Die-Cast Aluminium With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots & Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage 36W And System Lumen Output Of Not Less Than 3020 Lumens, Beam Angle Should Be Narrow : 15/25/40 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 240V Ac, Provided With Internal High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver Complying To Bis Standard Is 10322 ,Color Temperature : 3000K Cri 70, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd/Cob Led Chips. The Successful Bidder Shall Submit The Product Data Sheets, Lm80 Report Issued By Led Manufacturer Along With The Bis Certificate.Make: Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Floodlight Projector Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Pressure Die-Cast Aluminium With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots & Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage 18W And System Lumen Output Of Not Less Than 1550 Lumens, Beam Angle Should Be Narrow : 15/25/40 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 240V Ac, Provided With Internal High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver Complying To Bis Standard Is 10322 ,Color Temperature : 3000K Cri 70, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd/Cob Led Chips. The Successful Bidder Shall Submit The Product Data Sheets, Lm80 Report Issued By Led Manufacturer Along With The Bis Certificate. Make: Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of Static White 3000K Neon Flex With Diffused And Homogenous Light Suitable For Outdoor Applications Of Façade Lighting. Silicon Extrusion Flexible Tubes With Side Bending Option. Silicon Extrusion Technology Having Advanced Process, With High-Efficiency Production Capacity And Environmentally-Friendly Characteristics. Additionally, With High Grade Appearance, Soft Bend Flexibility, Strong Impact Resistant And High Weather Resistance. Uniform, Dot-Free And Smooth Lighting Performance Up To 5M. On Field Cuttable And Assembly, With Endcap Sealed By Gluing Process. Power Consumption Should Be Between 12~14W/M And Have Atleast 120 Leds Per Meter With 120° Beam Angle. Ingress Protection Should Be Ip 67. And Ik Rating Ik07. Size 10Mm X20mm Side Bend. Dimmable Available With Pwm Signal. Operating Temperature: -10°C To 45°C. The Fixture Shall Have Input Voltage For 24V Dc, With External High Efficiency Driver Having Power Factor 0.90, Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided. The Lumen Maintenance L70@ 25 °C Of The Led Shall Not Be Less Than 70% Of The Initial Lumen After 30,000 Burning Hours, With Suitable Aluminium Mounting Profile. * Power Supply: Dc 24V * Operating Temperature Range: -10°C To +45°C * Led Make: Cree/ Osram/ Lumiled/ Seoul/ Nichia/Sanan/Epistar Make: Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Installation Testing And Commissioning Of Smart Lighting Panel , Supplyof 3M Decorative Single Arm Cameroon Pole With 72W Sabik Ø480mm Crown Tm Pc:- 6M Height Designer Decorative Single Arm Pole Made In Combination Of Steel Pipe Which Is Fabricated Using 114 Mm(+/-3%)Dia Grooved Pipe X 4Mm Thick Base Section With Minimum Height Of 2000Mm. The Pole Is To Be Provided With A Surface Mounting Suitable Base Plate Dia Of 350 Mm And Suitable Thickness As Per Is Standards And Structural Reports. Decorative Knob On The Top Is Made Of Cast Aluminium In Single Piece Of Minimum Height 360Mm. The Pole Should Be Provided With An Inbuilt Junction Box To Fix Four-Way Connector And 6A Mcb At The Bottom - The Inbuilt Box Should Have A Flush Door Of Suitable Size. The Decorative Pedestal To Be Mounted On A Suitable Size Steel Plate. The Pole Shall Be Hot Dip Galvanized. . The Suitable Size Foundation Bolt Shall Be Supply Along With The Pole Of En 8 Grade. The Manufacturer Needs To Provide A Structural Analysis For Structural Stability Of The Pole With The Relevant Is Standards Is 1239/1161/E250 Needs To Be Clearly Mentioned. The Same Needs To Be Confirmed In Form Of Test Certificates From The Manufacturer. Internal Wiring Backelite Sheet And Mcb Included Please Refer The Attached Drawing No - Cameroon 6M Sa Tm Pole. Including 72W Post Top Fixture Suitable To Mount 72W ± 10% With Mcpcb Of Not Less Than 1.6 Mm Thickness And Cu Of 35 Microns And 2.5 Thermal Conductivity For Fixture. The Led Used Should Be High Power Epoxy Leds (Make- Osram/Bridgelux/Nichia/Cree) With Macadam /= 5 And Cri /= 70 And Cct 4000K. The Luminaire Should Have System Efficacy (Lumens/Watt) 110 Lumens/Watt. The Luminaire Should Be Having A Warranty For A Period Of 5 Years Against Any Manufacturing Defects. The Manufacturer Should Have Internal Testing Equipments Especially 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturer Shall Submit The Lm 80 Report For Led Used In The Fixtures. Similar To Model No. Sabik Ø480mm Crown Tm Pc Clear Sl. The Luminaire Should Be Rohs Compliant As Per Government Notification And With A Valid Bis Number. Luminaire Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Installation Testing And Commissioning Of Junction Box Including Terminations Of Size 130 X130 X 77 Mm Of Make Hensel , Charges For Installation Testing And Commissioning Of All Light Fixtures Of Façade Illumination Of Shantadurga Temple And Mahamaya Temple. , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core25sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core10sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply And Making Cable End Terminations With Compression Gland And Aluminium Lugs For Following Sizes Of Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. (4) 2 X 10Sq.Mm , Supply And Making Cable End Terminations With Compression Gland And Aluminium Lugs For Following Sizes Of Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. (6) 2 X 25Sq.Mm , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs. D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately).(A) In Soily Strata , Supplying And Laying 25 Mm X 5 Mm Gi Strip In 40 Mm Dia Gi Pipe From Earth Electrode As Required , Supply, Installation, Testing & Commissioning Of Diesel Generator Set 25Kva @20 Kwe With Volvo Eicher Engine, Canopy Made Of Composite Polymer-Based Material, Glass Reinforced Polymer (Grp) Acoustic Enclosure Which Can Be Recycled When Replaced Having Canopy Dimension Of 2825X1090x1425mm (Lxwxh) With Total Canopy Weight Not Exceeding 900Kg. Output Continuous Rating 3 Ph, 415V, 50 Hz 0.8 P. F A.C Supply. A Totally Enclosed Water Cooled 4-Cylinder Engine Developing 38 Bhp At 1500 Rpm With 10% Overload For 1Hour In 12 Hours. The Generator Canopy Shall Be Of Non-Metallic, Non-Rusting I.E. Corrosion Free, Weatherproof, Material Suitable For Coastal And High Humidity Conditions. The Dg Set Shall Comply With Cpcb Iv+ Noise Norm With Sound Absorbing Material To Restrict Sound Level Up To 75Db At 1.0M With The Silencer Positioned Inside The Canopy. The Canopy Shall Maintain Certified Sound Level For Minimum Of 15 Years. The Inbuilt Tank Fuel Capacity At 85 Litres & Maximum Fuel Consumption 5.3 Ltr/ Hr @ 75% Loading. The Generator & Panel Canopy Material Shall Contain Fire Resistant, Additives With Self -Extinguishing And Non -Conductive Properties. The Controller Should Be Fixed In Grp Panel Box Having Metal Hinges With Ss Finish Should Be Welded From Inside Of Box Size Of 650X450x200mm With Box Having Powder Coated In Ral9001 Mounted At Rear Side At Height Of 954Mm From Ground Level. The Dg Should Come With Low Vibration As Per Is8528 Part 9 & Should Be Aesthetically Pleasing In Colour Combination Of White & Anthracite Grey For Canopy With Ral9001 -Ral 7016 Respectively With Base Frame Size Of 285Mm Made Up Of 2.5Mm Thickness In Ral 9005 Maintaining 2 Coat Of Primer & 1 Coat Of Painting Process Thickness 80Microns. All The Painting Shall Be Done By Qualified Painters. Reference To Cat No- Grp Pkgvef-Iv25 Paikane Make Or Equivalent. , Supplying And Erecting Outdoor Type 5 To 7 W Led Focus Light Fitting Complete With Ip67, 24Vdc, 60W Driver, / Power Supply (If Any), Connecting Wire, Including Gear Box And Junction Box For Cable Connectionwith All Necessary Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Beam Angle Requirement As Per Gtdc With 3000K Cct Of Suitable Make Wipro,Legero,Bajaj,Jaquar,Vin Led,K-Lite,Philips Complete With All Required Accessories . , Supplying And Erecting 15 W Wall/Column-Mounted Rectangular Type Led Downlight Ip 65 Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,With 3000K Cct Of Suitable Make Wipro,Legero,Bajaj,Jaquar,Vin Led,K-Lite,Philips. Complete With All Required Accessories . , Supply Of High Quality Static White (3000K) Linear Wall Washer In 1000Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 40W And System Lumen Output Of Not Less Than 3250 Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make: Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Linear Wall Washer In 1000Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 24W And System Lumen Output Of Not Less Than 1950 Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Linear Wall Washer In 1000Mm Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Extruded Aluminium Alloy With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots To Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage Not Exceeding 15W And System Lumen Output Of Not Less Than 1180Lumens, Beam Angle Should Be 10X60 /15X45/25 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 24V Dc, Provided With External High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver. Luminaire Complying To Bis Standard Is 10322 ,Color Temperature : 3000K, Cri80,, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd Led Chips. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturere Shall Submit The Lm79 & Lm 80 Report Along With The Supply Of Material Along With The Bis Certificate. Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Floodlight Projector Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Pressure Die-Cast Aluminium With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots & Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage 40W And System Lumen Output Of Not Less Than 3320 Lumens, Beam Angle Should Be Narrow : 15/25/40 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 240V Ac, Provided With Internal High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver Complying To Bis Standard Is 10322 ,Color Temperature : 3000K Cri 70, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd/Cob Led Chips. The Successful Bidder Shall Submit The Product Data Sheets, Lm80 Report Issued By Led Manufacturer Along With The Bis Certificate.-Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Floodlight Projector Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Pressure Die-Cast Aluminium With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots & Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage 24W And System Lumen Output Of Not Less Than 1950 Lumens, Beam Angle Should Be Narrow : 15/25/40 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 240V Ac, Provided With Internal High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver Complying To Bis Standard Is 10322 ,Color Temperature : 3000K Cri 70, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd/Cob Led Chips. The Successful Bidder Shall Submit The Product Data Sheets, Lm80 Report Issued By Led Manufacturer Along With The Bis Certificate. Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of High Quality Static White (3000K) Floodlight Projector Having Precies Beam Angle As Per Design Or Site Requirement Suitable For Façade Lighting Applications. Housing To Be Made Of Pressure Die-Cast Aluminium With Excellent Heat Management System To Ensure Proper Heat Dissipation And Thermal Stability Of The Luminaire. The Luminaire Shall Have Electrostatically Applied Polyester Powder Coating Finish. Luminaire Shall Be Suitable To Operate In A Temperature Range Of -10°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25°C. The Lens Shall Be Made Of Anti-Aging & Anti Uv-Pmma/Pc Material And Able To Minimize Hot Spots & Insure Proper Light Distribution. Suitable For Outdoor Weather Proof Conditions Having Ip66 Ingress Protection. Transparent Toughened Glass Having Impact Resistance Protection Of Ik08. The Luminaire Shall Have System Wattage 12W And System Lumen Output Of Not Less Than 1550 Lumens, Beam Angle Should Be Narrow : 15/25/40 Degree/As Per Site Condition, The Fixture Shall Have Input Voltage Of 240V Ac, Provided With Internal High Efficiency Driver Operating On 240V Ac, Power Factor 0.90 @ Full Load, Internal Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided In The Driver Complying To Bis Standard Is 10322 ,Color Temperature : 3000K Cri 70, Operating Temperature : -10°C To +50°C, Operating Humidity : 10%-90%, Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia, Bridgelux To Insure Higher Lumen Output And Brightness With Smd/Cob Led Chips. The Successful Bidder Shall Submit The Product Data Sheets, Lm80 Report Issued By Led Manufacturer Along With The Bis Certificate.Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supply Of Static White 3000K Neon Flex With Diffused And Homogenous Light Suitable For Outdoor Applications Of Façade Lighting. Silicon Extrusion Flexible Tubes With Side Bending Option. Silicon Extrusion Technology Having Advanced Process, With High-Efficiency Production Capacity And Environmentally-Friendly Characteristics. Additionally, With High Grade Appearance, Soft Bend Flexibility, Strong Impact Resistant And High Weather Resistance. Uniform, Dot-Free And Smooth Lighting Performance Up To 5M. On Field Cuttable And Assembly, With Endcap Sealed By Gluing Process. Power Consumption Should Be Between 10~14W/M And Have Atleast 120 Leds Per Meter With 120° Beam Angle. Ingress Protection Should Be Ip 67. And Ik Rating Ik07. Size 10Mm X20mm Side Bend. Dimmable Available With Pwm Signal. Operating Temperature: -10°C To 45°C. The Fixture Shall Have Input Voltage For 24V Dc, With External High Efficiency Driver Having Power Factor 0.90, Surge Protection 4Kv And Other Protections Including Ocp, Ovp, Scp, Otp Shall Be Provided. The Lumen Maintenance L70@ 25 °C Of The Led Shall Not Be Less Than 70% Of The Initial Lumen After 30,000 Burning Hours, With Suitable Aluminium Mounting Profile. * Power Supply: Dc 24V * Operating Temperature Range: -10°C To +45°C * Led Make: Cree/ Osram/ Lumiled/ Seoul/ Nichia/Sanan/Epistar Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Supplyof Decorative Post Top Led Luminaire Is Designed With A Robust Die-Cast Aluminium Housing And A Clear Injection Moulded Polycarbonate Diffuser,Ensuring Long Life And Durability Against Outdoor Environmental Conditions. It Features An Ingress Protection Rating Of Ip65 And An Impact Resistance Of Ik08, Making It Both Dust-Tight And Resistant To Heavy Impacts. The Luminaire Is Aesthetically Designed With An Overall Diameter Of 460 Mm And A Height Of 785 Mm, And It Is Suitable For Mounting On A Ø 60 Mm Pole Pipe. Top Cover Made Of Spun Aluminium With Decorative Knob On Top Made Of Die Cast Aluminium As Shown In The Drawing For Unique And Better Aesthetics. The Luminaire Should Have Effective Heatsink For Thermal Management For Longer Life Of The Leds. The Luminaire Shall Be Provided With Type V Optics To Provide Uniform Photometric Distribution Suitable For Typical 360 Degree Illumination And Facilitate Minimum Glare, With Degree Of Protection As Ip65 Lamp Compartment. The Design Of The Fixture Has To Be The Same Aesthetics As Shown In The Drawing. The System Ac Wattage Of The Luminaire Shall Be 45W (± 10%) With Mcpcb Of Not Less Than 1.6 Mm Thickness And Cu Of 35 Microns And 2.5 Thermal Conductivity For Fixture. Colour Temperature (Cct) Of 3000K, Colour Rendering Index Cri /= 70 And Residual Flux Of 70% (L70) @ 50,000 Hours At Ta Of 25°C. The Luminaire Shall Be Suitable For Operating Within Temperature Range From - 10°C To + 45°C. The Led Used Should Be High Power Leds (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) With Macadam /= 5. The Luminaire Should Be Designed To Operate At Any Voltage From 140V To 280V, With Power Factor = 0.95 And Shall Be Provided With Optional Built In Over Voltage And Under Voltage Protection And Internal Surge Protection Of 4/4 Kv In Both Common & Differential Modes And External Surge Protection Of 10 Kv, Electrical Class I. The Driver Arrangement Should Be Such That It Can Be Easily Maintained Without Opening The Ip65 Lamp Compartment. All The Mounting Hardware Shall Be Ss304/316 Grade For Better Life. The Luminaire Shall Comply With Safety Requirements Of Applicable Bis Standard And The Bidder Shall Submit A Copy Of Valid Bis Certificate. Overall Outer Dimensions Of Luminaire Shall Be Ø460mm (±3%) And 785Mmh (±3%) Height And The Shape Shall Be As Per The Sketch Attached Herewith. The Luminaire Should Be Having A Warranty For A Period Of 5 Years Against Any Manufacturing Defects. The Manufacturer Should Have Valid Iso 9001:2015. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. The Manufacturer Shall Submit The Lm 80 Report Along With The Tender. Similar To Model No. Columba Pt 45W Opal Led 30K . The Luminaire Should Be With A Valid Bis Number. Make Reytek, Suncity, K-Lite, Dwarka Casting, Havells As Directed By The Engineer Inchrage. , Charges For Installation Testing And Commissioning Of All Light Fixtures Of Poles And Compund Lights Of Kelbai Temple.
Contract Date: May 31, 2026 Contract Value : 2.23 Crore
Government Departments No of Bidders 3
7.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
8.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
10.
Housing Urban and Rular Development #10409446 Price Bid
1)Annual Repair Maintenance of Various Electrical Installation And Mechanical Equipments Of 119 Type-Iii,Residential Quarters For The Staff Of Gnctd Of Delhi At Sector-11,Rohini,Delhi.(Sh Miscellaneous Ei Work)-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group A 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group A 3 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm 4 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm 5 b) 3 x 4 sq. mm 6 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 7 Painting of Existing Pole & Numbering of pole in installed position of height upto 6 mtrs with one or more coats aluminium paint after scapping of old peeled, rusted paint and making even the surface with putty/ filler on complete length of the pole including the cost of hire charges for trolley mounted ladder/tower wagon of suitable height etc. as required at site. 8 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 9 Providing and fixing hard drawn steel wire fabric of size 75 x 25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. 10 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 watt 11 Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flickershould be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim a) 18 watt 12 Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 100 watt 13 Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 72 Watt 14 SITC of 200 mm non metalic vantilating fan with louvers/ shutters suitable for 230 V AC supply i/c making hole in the glass or by removing glass and grill to suit the size and packing remaining hole with suitable size 3mm fiber sheet to make good the damage, repair, connection with 3-core 1.5 mm PVC insulated wire etc. as required. 15 Supplying and fixing of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required but without lamp. 16 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 17 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 18 Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size in DWC/HDPE/ RCC/ HUME/METAL as required. (a) 4 X 25 sq. mmAlu. Cable. 19 Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required.(a) 4 X 25 sq. mmAlu. Cable. 20 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal) 21 Cutting of R.C.C. / Bitumen Road etc upto depth of 30 cm work, cutting by machine including making good as same as earlier and disposal of unserviceable material as per direction of Engineer - in- charge etc as required complete at site and no payment for other items by department. 22 Supplying of following electrical accessoriessuitable for existing different type fitting/switch box etc. as required a) SP 5/6 A, one way modular switch, ISI marked 23 b) SP 15/16 A, one way modular switch, ISI marked 24 c) 3 pin 5/6 A modular socket outlet, ISI marked 25 d) 6 pin 15/16 A modular socket outlet, ISI marked 26 e) SP 5/6 A One Way Switch Piano Type ISI Marked 27 f) SP 15/16 A One Way Switch Piano Type ISI Marked 28 g) 3 pin 5/6 A Piano socket outlet, ISI marked 29 h) 6 pin 15/16 A Piano socket outlet, ISI marked 30 i) 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 31 j) 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 32 k) PVC Batten / Angle Holder 33 l) 63 amps ratings DP MCB 34 m) 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing 35 n) 300mm sweep metallic heavy duty 1400 RPM Exhaust fans 36 o) 2.5 MF Capacitor 37 p) 25A Modulare SPMCB C Curve 38 q) 6A, to 32 A, ratings, SP MCB, C Curve, 10 KA Breaking Capacity 39 r) 6A, to 32 A, ratings, DP MCB, C Curve, 10 KA Breaking Capacity 40 s) 63 A, rating, 2 pole RCCB, 30mA 41 t) One module stepped type electronic Piano fan regulator 42 u) 3mm Thick Phenolic Laminated Sheet 43 v) Call bell/ buzzer, single phase
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
11.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
12.
Educational and Research Institute #10320058 Price Bid
Supply Of Tools And Equipment For Different Laboratories And Workshops Of Central Calcutta Polytechnic.- 1 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmera Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers. Support Almost All Pics. This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc. Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 2 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Idekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 3 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 4 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warrenty Against Manufacturing Defects 5 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 6 Analog Cro, 30 Mhz, Dual Trace 0-600V, Ac / Dc 7 Trainer Kit To Study Switching Characteristicsand Vi For Scr, Igbt, Scs , Triac And Diac, 0-100V Minimum, 0-5A Load Current 8 Scr Trainer , 0-100V, 0-5A 9 Scr Firing Trainer, R Firing Trainer, 10-90 Degree For 230V Supply, 50Hz 10 Ujt Trainer, Upto Khz, Amplitude 0-60V 11 Scr Commutation ( A, B, C ) Trainer , Compatible To 230V Ac, 50Hz 12 Scr Commutation ( D, E, F ) Trainer, Compatible To 230V Ac, 50Hz 13 Half Controlled Rectifier, 0-100V 14 Full Controlledrectifier, 0-100V 15 Ac Regulator Trainer, Compatible To 230V, Variable Output Upto 230V 16 Dc Series Motor Drive Using Scr, Drive Should Be For 3Hp Motor 17 Separately Excited Shuntmotor Drive Using Scr, Drive Should Be For3 Hp Motor Atleast. 18 Setup To Study Speed Control Of 3-Phase Induction Motor Using Pwm, Drive Should Be 35Hp Motor 19 Flat Plate Solar Collector, Collector Body-Sturdy, Pure Polyester, Powder Coated Frame, 2Sqm, 9 Nos. Copper Fins And Tubes. 20 Vi Charactertics Of Pv Cell Trainer Kit 21 Solar Water Heating System 22 Pyranometer, Sp [ Ecial Selectivity ( 350 To 1500 Nano Mete, Tilt Responce-0-90◦ At 1000W / Sq.M, Temp Response – ( -10 ) Degree, Field Of View 180◦ 23 Solar Cooker, Frp Body, 23”X23”X9”, Reflector Material-Mirror Glass 4Mm, 4 Nos Aluminium Container Covered With Toughened Glass 4Mm, Plain Glass 4Mm, Insulation Material – Glass Wool, Inbuilt Analog Temperature Meter. 24 Flat Plate Solar Collector 25 Power Factor Improvementby Static Capacitor, 12.5 Μf, 450V, 200 Mhenry / 1Amp, Resistance 500Ω / 400W, Auxiliary Power Supply 230V Ac, 50Hz, Mcb 2Amp 26 Pelton Wheel Water Turbine Cut View Model 27 Franciswater Turbine Cut View Model. 28 Kaplan Water Turbine Cut View Model 29 Dc Series Motor Drive Using Step Down Chopper, Compatible Upto 3Hp 30 Synchronous Motor And Panel For V Curve Plotting, 415V, 3Hp With Required Control Panel. 31 3 Phase Resistive Load Box Upto 15 A, 415 V 32 Time Period Of Oscillation Of A Cantilever-Metre Scale ( Wooden - 2 Nos. ) , G. Clamp ( Metallic ) -02 Nos, Slotted Weight ( 4 No. Each Of 50 Gm ) Brasssed Chromed-02 Set. Slotted Weight Holder With Hook ( Metallic ) -05 Nos. Stop Watch ( Dial 30 Sec, Max Time Time 30 Minutes, Least Count 0.1 Sec, Made Of Stainless Steel, Tested At Nabl Acreditated Lb 33 To Verify Kirchhoff’S Law Using Electrical Circuitsi ) Kirchoffs Law Trainer Kit With Meters ( Standard ) Ii ) I.C Regulated Power Supply, Output : 0-9 V, 0.2 Volt / Div @ 500 Ma Over Voltage And Over Current Protectioniii ) Variable Resistors ( 0 To 10K, 3 Values ) Plug Type Resistance Box ( Standard Quality Manganin Coils ) Iv ) Digital Multi-Meter:01 No. Dc Voltage: 0-200 Mv- 1000V , Dc Current: 0-20 Ma -10A, Ac Voltage: 0-20V- 700V, Ac Current: 0-20Ma-10A , Resistance : 0-200 Ohm -2 Mega-Ohm. Capacitance: 0-20 Nf- 200Μf, Frequency: 0-200 Khz, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 34 Galvanometer By Half Deflection Method.Tablei ) Table Galvanometer ( Moving Coil Weston Type ) - 3 Nos. ( Known Resistance And Figure Of Merit ) , Range : 30-0-30, Sensitivity : 2 Micro-Amp / Div ; Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250Mm X 200Mm, Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. Ii ) Battery Or A Battery Eliminator ( 0 - 6 V ) - 03 Nos.Iii ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) , Range In Ohms :0 To 10K Ohmsiv ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) - , Range In Ohms :0 To 200 Ohms., V ) Fractional Resistance Box, - 03 Nos. Range : 0 – 10 Ohm Vi ) One Way Keys ( Standard - 01 No. Pack Of 5 Nos. ) , Brass Block With Brass Terminals. Block Size: 56 X 10 X 10 Mm. Vii ) Digital Multi-Meter- 01 No.Specification Issame As Item No 33. ( Iv ) , V ) Connecting Wires ( Standard, 1 Coil Each ) - 35 Conversion Of Galvanometer Into An Ammeter Or A Voltmeter.I ) A Galvanometer, ( Known Resistance And Figure Of Merit ) , Specification Issame As Item No 3 ( I ) . ( Ii ) , A Battery Eliminator ( 0 – 3V, - 03 Nos.Iii ) One Way Key ( Standard ) - 01 Nos., Specification Issame As Item No 34. ( Iv ) Iv ) Wire Rheostat - 04 Nos. Range 0 – 200 Ohm, Length : 30 Cm, Dia 50 Mm ( Approx ) , Current : 2.5A , Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab. V ) Dc Milli-Ammeter - 03 Nos., Range 0-30 Ma , ( Div. 1Ma ) , Accuracy : + / - 1%, Permanent Magnet Moving Coil Type. Bakelite Case, Size: 250 Mm X 200 Mm. Anti-Parallax Mirror Scale, Knife Edge Pointer, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab.Vi ) Dc Voltmeter - 03 Nos. Range 0 – 3 V, ( Div. 0.05 V ) , Accuracy : + / - 1%., Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm. Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab.Vii ) Constantan Or Manganin Wire ( 26 Or 30 Swg, 10 Nos. ) , Viii ) Connecting Wires ( Standard ) . 36 Pn Jn Diode Characteristicsi ) Pn Jn Diode Characteristics Trainer Kit ( Compact ) , For Both Si And Ge Diode With, Ii ) 4Mm Bs-4 Jack Terminal For Various Test Point, Iii ) Power Led Indication, Iv ) Built Analogue Meter For Voltage And Current, Measurement - ( A ) Voltmeter : 0-3V, 0.05V / Div, ( B ) Voltmeter : 0-10V, 0.2V / Div, ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div, Measurement. ( A ) Voltmeter : 0-3V, 0.05V / Div ( B ) Voltmeter : 0-10V, 0.2V / Div ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div Micro Ammeter: 0-100 Μa, 1Μa / Div Variable Voltage Range By Potentiometer Arrangement : 0- 1.5V ( Forward Bias ) And 0 - 10V ( Reverse Bias ) Built In Regulated Dc Power Supply Ac Input : 230V Ac, 50Hz, +- 10%. Mounted On A Sophisticated Cabinet Accessories : Patch Cords. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 37 Po Box Experiment ( To Verify Series Law ) Post Office Box. ( Plug Type ) With .. Body Made Of Brass Inside Teak-Wood Made Case. Manganin Wire, Non Inductive Winding. Ratio Arms 10, 100, 1000 Ohm, Series Arms 1 To 5000 Ohm, 16 Coils. Two Tapping Keys ( 2 Mm Thickness ) For Galvanometerand Battery. Brass Made Plug Key ( Dia 7Mm, Length 20Mm Excluding Head ) And Brass Made Stud ( Thickness 12 Mm , Height 15 Mm ) . Connecting Terminals Should Have Heavy Threaded Knob. Wired Wound Resistor ( Fixed ) : Iso 9000 Certified Manufacturer. 5 Ohm, 1% Tolerance; - 10 Nos. 10 Ohm, 1% Tolerance;- 10 Nos. 20 Ohm., 1% Tolerance;- 10 Nos. Insulated Copper Wire For Electrical Connection, -2Roll Area 1.5 Square Mm. 38 To Verify Snell’S Law Of Refraction Of Light - 15 Set Rectangular Galss Slab , Crown Glass - 15 Nos Size : 4 Inch X 3.5 Inch X 1 Inch Drawing Board Made Of Soft Wood - 15 Nos Size : 18 Inch X 23 Inch, Good Quality. Stout Hair Pin.- 5 Box Board Pin - 5 Boxwooden Meter Scale ( 1 M ) - 2 Nos 39 Ohm’S Law Verification - 2 Set Ohms Law Apparatus Kitwith Built In ( Compact ) -2 Nos Dc Voltmeter, Range 0 – 3 V - 2 Nos Specification Issame As Item No 36. ( Iv ) Dc Milli-Ammeter - 3 Nos Range 0 To 500 Ma ( Div. 5 Ma ) , Accuracy : + / - 1% Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm, Knife Edge Pointer, Anti-Parallax Mirror Scale, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab 40 To Verify Inverse Square Law Of Radiations Using A Photo Electric Cell. - 2 Set Photo Cell ( Selenium ) ( Mounted In The Metal Box With Connections Brought Out At Terminals ) Lamp Holder With Bulb ( 60W Bulb ) Moving Coil Analog Micro Ammeter Mounted On The Front Panel And Connections Brought Out At Terminals ( Range 0 - 500Μa ) . Moving Coil Analog Milli-Voltmeters Mounted On The Front Panel And Connections Brought+ Outat Terminals ( Range 0 -1000 Mv ) Wooden Bench Fitted With Scale ( Range ) Connecting Wires ( Standard, 1 Coil ) .- 1 Coil, 41 Capacitance And Permitivity Kit ( Digital ) ( To Determine The Permittivity Of Air At A Place ) - 2 Set 42 Focal Length And Magnifying Power:U-V Method. Optical Bench And Its Acessories ( Complete Set ) : 3 Sets Twin Bar 1.5 Meter Long Made Of Brass Chrome Plated Pipes Held In Strong Supports With Leveling Screws. One Pipe Is Graduated In Mm. Four Sliders With Four Sliders With Index Mark . Two Lens Holders And Two Pin Holders ( Made Of Brass ) Having Screw In Each Which Has Capability Of Vertical And Horizontal Displacement And With Two Pins Made Of Brass ( For The Determination Of Focal Length Of A Convex Lens By U-V Method ) . Spherical Double Convex Lenses With - 3 Nos Focal Length – 10 Cm, Diameter 60 Mm - 3 Nos Focal Length – 15 Cm, Diameter 60 Mm - 3 Nos Focal Length – 20 Cm, Diameter 60 Mm.- 3 Nos 43 Radius Of Curvature Of Concave / Convex Surface - 5 Nos Spherometer ( Complete Set ) With Linear Scale In Mm Circular Scale Divisions:100 Convex Mirror - 5 Nos Concave Mirror - 5 Nos Plane Glass Slab ( Big Size ) - 5 Nos Plane Mirror - 5 Nos 44 Spring Constant By Hooke’S Law Apparatus - 3 Set Retort Stand With Clamp, Spring With Hook At Both Ends, Weight Hanger With Hook ( 50 Gm ) Slotted Weight ( A Set Of Six ) 50 Gmeach A Vertical Wooden Scale A Fine Pointer 45 Co-Efficient Of Static Friction Between Wood And Glass. Horizontal Wooden Board With Glass Top, Fitted With Pulley At One End. Wooden Block ( With Slots On Top For Weight ) With Fixed Hook At One End. Weight Hanger With Hook. Slotted Weight ( 10 No. Each Of 20 Gm ) 46 Moment Of Inertia Of A Flywheel. Flywheel With Shaft. Weight Hanger. Stop Watch Meter Scale Slotted Weight ( Standard Set ) 47 Co-Efficient Of Linear Expansion Of A Metal Rod Pullinger’S Apparatus, With Scale And Thermometers. Optical Level High Resolving Power Telescope Meter Scale Thermometer A Metallic Rod 48 To Verify Boyles Law Boyles Law Apparatus : Complete Set With Accessories: Burette Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking Fitted On A Teak Wood Made Frame ( Height 120 Cm, Width 10 Cm., Thickness 2.5 Cm ) With A Metrescall Attached At The Middle Of The Frame And Standing On A Cast Iron Made Base ( Length 22 Cm And Breadth 5 Cm ) Having Three Legs Two In Front And One At Back Side Each Having Length 8.5 Cm. ) . Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod ( 8 Mm Dia ) . High Quality Synthetic Tube ( 1.0 M Long ) Containing 750 Gm Hg. One Spare Synthetic Tube. ( With Extra 500 Gm Mercury ) . Fortin’S Barometer : ( Complete Set ) Brass Made, Supplied With Mercury Andcase Made Of Teak Wood. Open Plate Reflectors, Ringand Screws For Vertical Adjustments. A Dual Scale Graduated In 25 To 32 Inches And 64 Cm To 81Cm Is Read By Verniers Moving By Rack And Pinion, Reading To0.01 Inch And 0.1Mm Are Enclosed In A Glass Cylinder.A Glass Cistern At The Lower End Of Barometer Isprovided With An Ivory Point To Adjust The Level Of Mercury. Mounted On A Wooden ( Teak Wood ) Base. Covered With Glass Case. A Thermometer Is Provided On The Wooden Base. 49 To Find The Viscosity Of A Given Liquid ( Glycerin ) By Stokes Law With The Following Stake’S Law Apparatus For Viscosity Measurement : Neutral Glass Thick Tube About 1.25 Inch Diameter And 1 Meter Long Fitted On A Teak Wood Made Wooden Stand With A Meter Scale. The Glass Tube Is Having A Nozzle At The Bottom Fitted With A Rubber Tube And Pinch Cock. A Net Hanger And A Small Spherical Ball Of Three Different Dia ( 5 Each ) . Glycerine : 2 ( Two ) Litre Per Apparatus Castor Oil: 2 ( Two ) Litre Per Apparatus Screw Gauge Stop Watch Meter Scale 50 Relative Density Of Sand By Specific Gr. Bottle Hydrostatic Balance: Capacity 250G And Sensitivity 1 Mg, Body Made Of Teak, Wood, Made Of Brass With Others Accessories ( For The Determination Of Specific Gravity Expt. ) .Std. Weight Box:Chrome Plated Brass Weightsin Box, Containing From 1Mg To100g ( Grade “A” ) Isi Standard . Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accredited Lab.- 4 Nos. Beaker, 150 Ml Capacity, Borosil. - 5 Nos. Beaker, 100 Ml Capacity, Borosil. - 5 Nos. Specific Gravity Bottle, 50 Ml Capacity. - 20 Nos. Wooden Bridge ( Teak Wood Made ) . - 5 Nos. 51 Computer -Key Highlightsprocessor- ( Intel 7Th Gen Or Amd Ryzen 3000 Series / Threadripper 2000 Series ) Or Higher Cpu Operating System- Microsoft Windows 10 ( 64-Bit ) , Version 1909 Or Laterram- 8 Gb Ddr4 Or Higher Storage- Recommended Ssd- 240 Gb Or Higher For C Drive And 1 Tb Hdd Or Higher For Storage 52 Laser Printer-Hp Laser 108A Single-Function Printer 53 Printer Cartridge-For Hp Laser 108A Single-Function Printer 54 Barcode Label Printer-Model Tvs Lp 46-Product Dimensions ‏ : ‎ 18.5 X 21 X 28 Cm; 4.52 Kilograms Manufacturer ‏ : ‎ Tvs Electronics Limited Asin ‏ : ‎ B08gsr5n6j Item Model Number ‏ : ‎ Lp 46 Neo Manufacturer ‏ : ‎ Tvs Electronics Limited Item Weight ‏ : ‎ 4 Kg 520 G Item Dimensions Lxwxh ‏ : ‎ 18.5 X 21 X 28 Centimeters Generic Name ‏ : ‎ Label Printer 55 Ribbon-Sun Retail 105Mmx300mts Thermal Transfer Barcode Labels Ribbon Super Wax For Printer ( Wax ) For Citizen Zebra Tvs Tcs Hbrt Godex Printer Paper Label ( Black ) 56 Paper Roll-Best Label Hub50x25 ( Thermal ) Barcode Labels Stickers, 4000 Label In Roll, 2Up 57 Bar Code Scanner-Tvs Electronics Bs-C101 Star Barcode Scanner | With A Top Trigger Button | 1D Linear Imager To Scanner | Speed Of 330 Scans Per Second | Enabled With Ultra Scan-Decoding 58 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmer A Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers.Support Almost All Pics.This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc.Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 59 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Id Ekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 60 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 61 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warranty Against Manufacturing Defects 62 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 63 Speaker Trainer To Study The Frequency Response And Directivity Characteristics. Built In Dc Power Supply, Audio Frequency Generator, Suitable Amplifier With Gain Adjustment, Sound Level Meter, 360 Degree Circular Scale With 2 Ft Diameter With Holding Structure, Clearly Printer Front Panel, Instruction Manual 64 To Study The Internal Layout Of B&W Tv Receiver And Measure Voltage Level To Sketch Composite Video Signal At Different Stages Of Tv Receiver:B&W Tv Receiver Trainer With Built In Facilities To Observe Composite Video Signal, Vertical And Horizontal Signal, Crt Based B&W Kit, Adjustment Must Be Provided For Sound, Vertical And Horizontal Amplifier In Front Of The Panel, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 65 Study Of Internal Layout Of Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 66 Fault Finding In Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Different Fault Switch To Be Provided To Create Fault And Observe The Results, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 67 Test Various Sections Of Led Tv Receiver: Led Tv Trainer To Test Different Sections, Power Supply, Processor Card, , Led Screen, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 68 Dth Trainer With Tools For Installation 69 Demonstration Of Photocopier Trainer: Photocopiertrainer To Study Its Demonstration Working, Clearly Printed Front Panel, Instruction Manual 70 Demonstration Of Microwave : Microwavedemonstration Set Up To Study Its Working, Clearly Printed Front Panel, Instruction Manual 71 Demonstration Of Washing Machine: Washing Machine Demonstration Setup With Clearly Visible Transparent Cover, Clearly Printed Front Panel, Instruction Manual 72 Demonstration Of Refrigerator: Refrigeratortrainer With Facilities To Measure Different Parameters Like Voltage, Current, Power, Efficiency And Compressor Load, Clearly Printed Front Panel, Instruction Manual 73 Demonstration Of Digital Camera:Branded Digital Camera Demonstrator With Clearly Visible Parts. 74 Measurement Ofunknown Inductance By Maxwells Bridge:Maxwells Bridge Trainer For Measurement Of Unknown Inductance, 1 Khz 10V P-P Sine Wave Ac Source, Three Different Unknown Inductors, Suitable Bridge Balance Facility With Null Detector, Clearly Printed Front Panel, Instruction Manual 75 Lvdt Trainer Kit With Built In Power Supply, On Board Printed Diagram, Measuring Range Of Lvdt ( -10Mm To +10Mm ) , 1 Khz Ac Source, Digital Display For Voltage, Clearly Printed Front Panel, Instruction Manual. 76 Strain Gauge Trainer, Load Cell Strain Gauge Platform With Changeable Compression / Tension Mode, Suitable Instrumentation Amplifier, 500 Gm Weight Box, Calibrated Digital Display, Clearly Printed Front Panel, Instruction Manual. 77 Characteristics Of Rtd ( Pt100 ) : Trainer Kit To Measure The Temperature And Change Of Resistance Of Rtd, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual. 78 Characteristics Of Thermister: Trainer Kit To Measure The Temperature With Thermister, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual 79 Calibrate Single Phase Energy Meter With Phantom Load:Energy Meter Trainer Kit With Phantom Load Arrangement, Digital Voltmeter, Ammeter, Wattmeter, Single Phase Energy Meter, Clearly Printed Front Panel, Instruction Manual. 80 Calibrate Voltmeter With Cromptons Potentiometer: Calibration Set Up For Voltmeter, Volt Ratio Box, Standard Cell, Crompton Potentiometer, Mi / Mc Voltmeter, Clearly Printed Front Panel, Instruction Manual. 81 B-H Curve Experiment Training Kit 82 Hot Air Soldering Stationfor Smd Component Rework 83 Pid Controller Training 84 Bench Top Do Meter : Dissolved Oxygen Measurements In Ppm, Mg / L Or % Saturation.Accurate Readings In Varying Conditions With Temperature, Salinity And Barometric Pressure Compensation. Large Easy To Read Display. Ready Indicator Lets You Know When Readings Are Stable. Non-Volatile Memory Holds Up To 100 Data Points. Integral Electrode Holder Dissolved Oxygen Range0 To 30Mg / L % Saturation Of Oxygen Resolution 0.1% / 1%Resolution 0.01 Mg / L Accuracy ±0.5% Full Scale Salinity Correction Range 0 To 50 Ppt Temperature Resolution 0.1 Range Accuracy ±0.50C / ±0.90F 0 To 1000C / 32 To 2120F Resolution 0.1 Barometric Pressure Correction Power Range 450 To 825 Mm Hg 110 / 240 V Ac Smps 9V Dc Adapter 1.3 A. Range 450 To 825 Mm Hg110 / 240 Ac Smps 9V Dc Adapter 1.3 A Resolution 1 Accuracy Manual Input Method Galvanic 85 Conductivity Meter / Tds: For Routine Applications In Laboratories, Production Plants And Schools. Must Be Reliable, Accurate And Consistent Performance. Large Screen That Displays Conductivity Or Tds Readings With Temperature In 0C And 0F. Ready Indicator To Know When Readings Are Stable. Selectable Cell Constant Auto-Ranging Across 5 Conductivity And Tds Ranges Up To 5 Point Push Button Calibration Non-Volatile Memory Hold Up To 100 Data Points Integral Electrode Holder, Automatic Temperature Control Probe. Conductivity Range .1Μs / Cm To 200.0Ms / Cm Resolution 0.01Μs; .01Μs; 1Μs; 0.01Ms; 0.1Ms Accuracy ±1% Full Scale Cal. Points Automatic ( 4 Points ) Maximum 1 Per Range; Manual ( 5 Points ) ; Maximum 1 Per Range Cell Constant .01, 1.0 10.0 ( Selectable ) Tds Range 0.1 To 100 Ppt @ 0.5 Tds Factor ( To 200Ppt @ 1.0 Tds Factor ) Resolution 0, 01Ppm; 0.1Ppm; 1Ppm; 0.01Ppt; 0.1Ppt Power 110 / 240 V Ac Smps, 9V Dc Adapter, 1.3 A Output Rs-232 86 Electro Pneumatic Trainer Kitthe Pneumatic Kit Shall Be Of Sleek Design And Portable One With Wheels. This Unit Is To Be Provided With Standard Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Pick & Place Of Components Easier. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”. All The Components Used Shall Be Of Reputed Make Like Festo / Janatics / Rexroth Or Any Other Reputed Make Acceptable To Polytechnic. Vendor Has To Specify The Make With Catalogue.The Following Experiments Should Be Possible To Carry Out Using The Kit:A ) To Learn About The Fundamentals Of Pneumatics With Components ( Frl Unit, Compressor, Dc Valves, Pressure Control Valves, Pneumatic Cylinders, Accessories, Etc ) – Functions, Symbols, Working Principle & Applications. B ) To Build Up A Pneumatic Circuit With Applications Like Lifting & Holding A Load, Clamping / De-Clamping, Speed & Load Control In Double Acting Cylinder, Speed Control Of Pneumatic Motor Etc. Vendor Has To Provide The Learning Resources – Basics Of Pneumatics, Different Pneumatic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) :1. Air Compressors- Displacement 3Cfm, Working Pressure – 7Kg / Cm2 ( 7 Bar ) With 0.5Hp 650 Rpm Electric Motor 230V, 50Hz, 1 Phase With 0-10 Bar Pressure Gauge & Shut Off Valve With Suitable Hose And End Connector. 2. Filter Regulator And Lubricator ( Frl ) Unit With Pressure Gauge ( 10Bar ) – 1 No. 3. Direction Control Valves Of Different Configuration ( 5 / 2 Way Lever Operated -4 No., 5 / 2 Way Single Solenoid Operated - 2 No., 5 / 2 Way Double Solenoid Operated -2 No, & 5 / 3 Way Lever Operated - 3 No, 3 / 2 Way Roller Operated Valve – 1 No ) . The Size Of The Valves Shall Be Of ¼” Bsp. 4. Set Of Pressure Control Valves, One Way Valves, Flow Control Valves, Shut Off Valves, Or Gate & And Gate Shuttle Valves, Time Delay Valve, Quick Exhaust Valve ( Minimum – 1 No Each ) Or Of Sufficient Quantity To Execute The Experiments. The Size Of The Valves Shall Be Of ¼” Bsp. The Vendor To List Down The Type, Specification And Quantity Of Valves Offered. 5. Single Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement –1No. 6. Double Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement - 2 Nos. 7. Pneumatic Motor - 1 No, 8. Required Length And Quantity Of Pneumatic Hoses With Suitable End Fittings Of Quick Snap Type And Ell, Straight & Tee Fittings Of Required Quantity Have To Be Provided. 50% Extra Spares Of This Hoses And Fittings To Be Supplied. Details Of Supply Are To Be Specified In The Offer. 9. Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied.10. Required Electrical Controls With Sockets For Solenoids, Etc. Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 87 Electro Hydraulic Trainer Kitspecification: 1. The Hydraulic Kit Shall Be Of Sleek Design And Portable One With Wheels. 2. Provided With Standard Steel / Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Mounting Of Components Easier. 3. All The Products To Be Provided With Suitable Quick Disconnect Couplings. 4. All The Components Used Shall Be Of Reputed Make Like Rexroth / Vickers Or Any Other Reputed Make Acceptable To Polytechnic. Vendor To Specify The Make With Catalogue. 5. The Following Experiments Should Be Possible To Carry Out Using The Kit: A ) To Learn About The Fundamentals Of Hydraulics With Components ( Dc Valves, Pressure Control Valves, Flow Control Valves, Hydraulic Cylinders, Accessories, Etc., ) B ) To Build Up A Hydraulic Circuit With Applications Like Hydraulic Press Circuit, Clamping / De-Clamping, Meter-In / Meter-Out, Speed Control & Load Control In Double Acting Cylinder, Sequencing Circuit, Counter Balance Circuit, Etc. 6. Vendor To Provide The Learning Resources – Basics Of Hydraulics, Different Hydraulic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. 7. Operation & Maintenance Manual To Be Supplied - 2 Hard Copies And 1 Soft Copy With The Equipments. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) : 1 ) Trolley With Frame, No. Of Wheels - 4, Two Fixed & Two Swivel Type. Load Mounting Capacity: 500 Kg 2 ) Hydraulic Power Pack With Following Capacity: Operating Pressure: Around 40 Bar. Flow Rate: Around 5 Lpm. The Power Pack Includes The Following Components: A ) Hydraulic Tank Capacity Around 50 Litres. B ) Suitable Pump & Electric Motor ( Single Phase – 230V, 50 Hz, 1440 Rpm Induction Motor ) Coupled With Bell Housing And Mounted Externally Over The Tank With Vibro-Mounts. C ) Safety Relief Valve With Variable Pressure Setting. D ) Accessories Like Drain Plug, Suction Strainer, Return Line Filter, Electrical Power Source For Solenoid Valves, Valve Mounting Sub-Plates, Hydraulic Fittings, Etc. E ) Required Quantity ( Min. 8 Nos. ) Of Hydraulic Hoses Of Suitable Length With End Fittings And Quick Couplings, Transparent Hoses On Return Lines And Leakage Lines. 3 ) All Types Of Valves To Carry Out The Experiments Proposed. The Valves Include: A ) Solenoid Operated Dc Valves – 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types ( Solenoid Voltage: 24V Dc ) B ) Manual Operated Dc Valves 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types. C ) Pilot Operated Dc Valve4 / 2 Way – 1 No And 4 / 3 Way – 1 No D ) Pressure Relief Valve – 1 No E ) Pressure Reducing Valve – 1 No F ) Pressure Sequence Valve – 1No G ) Flow Control Valve – 1 No H ) Non-Return Valve- 1 No 4 ) Hydraulic Cylinders – A ) Single Acting Cylinder – Spring Return Type ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) B ) Double Acting Cylinder ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) Seals: Bushak&Shamban / Merkel / Freudenberg Or Any Other Reputed Make Acceptable To Polytechnic. Max Operating Pressure: 100 Bar, Normal Operating Pressure: 40 Bar Piston Rod: Chrome Plated And Hardened. 5 ) Hydraulic Motor: Type: Gear Motor / Piston Motor Direction Of Rotation: Bi-Directional Normal Operating Pressure: 40 Bar, Max. Pressure: 100 Bar, 6 ) Flow Meter – 1 No Type: Acrylic Hone Type Flow Meter With Scale, Rotameter, Working Pressure: Around 40 Bar 7 ) Proximity Sensor: 2 No Type: Contact Less Proximity Sensor Pnp Type, Operating Voltage: 24 V Dc, 8 ) Equipment Trays: 4 No, The Tray Design Is Such That The Supplied Components Can Be Kept In The Tray. Also The Trays Have Space For Each Individual Component. 9 ) Pressure Gauges – 5 No ( Glycerine Filled ) Of Suitable Range To Measure The Pressure At Various Points ( Pressure Line, Return Line, Reduced Pressure Line, Suction Line, Etc. ) 10 ) Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied. 11 ) Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 12 ) Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 88 Separating & Throttling Steam Calorimeter With Boiler Specification-This Set Up Mounted On A Bench Fully Instrumented To Determine Quality Of Steam At Pressure Of Steam 8.0-10.0 Kg / Cm2 Using Separating Throttling Calorimeter With Steam Condensing Plant, Non Ibr Small Steam Boiler Shell Fitted With Immersion Heater And Furnish With Safety Valve, Pressure Gauge, Digital Thermometer, Steel Lagging Jacket, Power Supply For Heating: 230 V, Single Phase Ac. Arrangement For Drainage Of Waste Water After Experiment. Operation & Maintenance Manual. 89 Spanner Set8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19 Mm Combination Spanners 90 Spanner Set 1 / 8 X 3 / 16, 3 / 16 X 1 / 4, 1 / 4 X 5 / 16, 5 / 16 X 3 / 8, 3 / 8 X 7 / 16, 7 / 16 X 1 / 2, 1 / 2 X 9 / 16, 9 / 16 X 5 / 8, 5 / 8 X 3 / 4 91 Supply And Installation Of Izod And Charpy Testing Machine With Specimen For Testing 92 Supply And Installation Of Torsion Testing Machine. Capacity 200 Nm, Power Supply- 260Vac At 50 Hz, 12 Months Warranty From The Date Of Installation, Least Count 0.1 Degree ( Deflection ) , Measuring Units- Nm, Ncm, Kgcm ( Selectable ) , Maximum Deflection- 180Degree, Accuracy + 1% Of The Reading 93 Electrode Holder Full Brass Body Inside 5Mm Electrode Size Dimensions ( Lxwxh ) -23.6X3.5X8.9 Mm Insulated Handle Made Of Fiber Glass Polyamide And Head From Dmc 94 Lathe Machine Hmt Lathe Machine, Nh22 Height Of Centers:220 Mm Swing Over Bed:500 Mm Swing Over Cross Slide: 270 Mm Swing In Gap ( Optional ) : 720 Mm Distance Between Centers: 1000 Mm Spindle Nose / Bore- A2-6* / 53 Mm Spindle Speed Range: 16 From 40 Rpm-2040 Rpm Forward And 7 From 60 Rpm-1430 Rpm Reverse Spindle Power= 11 Kw, Feed Range ( Longitudinal ) : 60 From 0.04- 2.24 Mm / Rev, Feed Range ( Cross ) : 60 From 0.02-1.12 Mm / Rev Lead Screw Pitch- 6 [ Or 4Tpi Acme ] Mm, Metric Threads: 48 From 0.5-28 Mm, Main Motor Power=7.5 ( Std. ) / 11.0 ( Opt. ) Kw, Tailstock Sleeve Travel= 200 Mm 95 Brinell Microscope Lamp 96 Coefficient Of Friction Tester Coefficient Of Static Frictio Tester ( Analogue ) 97 Experimental Setup For Determining Modulus Of Rigidity , Strain Energy, Shear Stress And Stiffness By Load Deflection Method ( Closed Coil Helical Spring ) Setup, Installation And Demonstration 98 Supply And Installation Of Morse Test Experimental Setupnumber Of Cylinder - 4 Cylinder 99 Model Of Impulse Steam Turbine Axial Flow Impulse Turbine 100 Layout Of Hydroelectric Power Plant Including Dam, Reservoir, Penstock, Nozzle, Hydraulic Turbine, Surge Tank Etc. ( All Models ) 101 Sprit Level 102 Bevel Protractor With Tapered Specimen For Angle Measurement 103 Gear Tooth Vernier Calliper Graduation-0.02 Mm, Accuracy -0.04 Mm 104 Tachometer Testing Range- 2.5 To 99999 Rpm, Resolution- 0.1 Rpm ( 2.5 To 999.9 Rpm ) And 1 Rpm ( Over 1000 Rpm ) , Accuracy- +0.05%, Detecting Distance: 2 To 20 Inch 105 Screw Pitch Gauge Range 0.25- 6.00 Mm Thread 106 Radius And Fillet Gauge Range 1 Mm To 7Mm 107 Plug Gauge And Ring Gauge Supply Of Plug Gauge ( 1 Unit ) And Ring Gauge ( 1 Unit ) 108 Sheet Metal Gauge Minimum Range 1 Mm To 30 Mm 109 Cut Section Model Of Shell & Tube Type Heat Exchanger 110 Cut Section Model Plate Type Heat Exchanger 111 Experimental Setup For Determination Of The Thermal Conductivity Of A Solid Metallic Rod 112 Cut-Section Model Of Check Valve 113 Cut-Section Model Of Needle Valve 114 Tig Welding Machine With Gas Cylinder 115 Projector : Projection System: 3Lcd Technology, Rgb Liquid Crystal Shutter Lcd Panel: 0.55 Inch With C2 Fin Colour Light Output: 3, 600 Lumen-2, 400 Lumen ( Economy ) White Light Output: 3, 600Lumen Resolution: Xga, 1024 X 768, 4:3 Native Contrast: 16, 000 : 1 Lamp: Uhe, 210 W, 6, 000 H Durability, 12, 000 H Durability ( Economy Mode ) Keystone Correction: Auto Vertical: + / - 300 , Manual Horizontal: + / - 300 Colour Reproduction: Upto 1.07 Billion Colour Throw Ratio: 1.48-1.77:1 Zoom: Manual, Factor: 1.2 Screen Size: 30Inches - 300 Inches Projection Lens F Number: 1.49 - 1.72 Projection Lens Focal Length: 16.9 Mm - 20.28 Mm Image: Optical: Specification For Laser Printer: Specification For Projector: Technology: Offset: 8:1 Usb Display Function: 3 In 1: Image / Mouse / Sound Interfaces: Usb 2.0 Type B, Rs-232C, Ethernet Interface ( 100 Base-Tx / 10 Base-T ) , Wireless Lan A / N, 5Ghz ( Optional ) , Vga In ( 2X ) , Vga Out, Hdmi In, Composite In, Stereo Mini Jack Audio Out, Stereo Mini Jack Audio In ( 2X ) , Cinch Audio In, Usb 2.0 Type A Other Feature: Av Mute Slide, Automatic Keystone Correction, Built-In Speaker, Digital Zoom, Direct Power, On / Off, Document Camera Compatible, Easy Osd Presetting, Horizontal And Vertical Keystone Correction, Network Projection, Osd Copy Function, Pc Free, Quick Corner, Split-Screen- Function, Iprojection App, Iprojection Set-Up By Nfc, Iprojection Set-Up Qr Code Warranty: 3 Years On Projector, Lamp: 1 Year Or 1, 000 Hours Whichever Is Earlier
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 16
West Bengal View Result →
13.
Drinking Water Supply and Sanitation #10279059 Price Bid
Tender For Rehabilitation Improvement And Basic Facility Of Parbati Dam District Dholpur. - 5.1.2Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 2 Dismantling doors, windows and clear story windows (steel or wood) shutters including chowhats, architrave and holdfastsetc. Complete and stacking 50 m lead of area 3 square meter and below 3 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 5 to 10 m depth 4 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 x 50mm x 16 gauge 5 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . WITH 225 mm sweep 7 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. withStainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 8 Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1.5 TR ISEER not less then 3.8 9 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for Superstructureincluding curing all leads of all construction materials including curing etc. complete. in cement sand mortar 1:4 10 Add extra over item No. 18 (b) for compaction in restricted area nearby structure or flanks by hand rammers or by pneumatic tampers. 11 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 10 to 15 m depth 12 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)By Mechanical Means: Grading- I (Using Screening Crushable type such as Moorum or Gravel)Using Screening Crushable type such as Moorum or Gravel 13 11.5.4Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 15 to 20 m depth 14 Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means 15 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 20 to 25 m depth 16 Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom 17 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. Beyond 25 m depth 18 Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8- 10 tonne capacity, finished to required level and grades.)(I)a Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour .Using VG-30 binder 19 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 20 Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder.(ii) Bitumen grade VG30 @ 4.50% 21 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.From 5 to 10 m depth 22 dismantling roofs with care including stacking of serviceable material and disposal of unservicable material within 50m lead for lime terrace 23 Supplying and lowering into holes and fixing of casing pipes of suitable diameter to enable drilling of minimum 48 mm dia grout holes. 24 dismantling stone slab roofing over wooden karries or RCC battens ( dismantling karries and battens to be paid for separately) including stacking of servicable material and disposal of unservicable material within 50 m lead 25 11.7Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grout after stage grouting including cost ofequipment, compressed air and etc. complete. 26 Dismanling old plaster or skirting , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead 27 11.8Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification. 28 Dismantling flooring with care including stacking of servicable material and disposal of unservicable material within 50 m lead for: cement concrete flooring 29 5.16.1Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 30 Supply and fixing of steel doors, with frame of hollow metal pressed section 105×60 mm as per I.S.I 1.25mm thick with double sheet shutter 1.00 mm thick M.S. sheet tospot welded and embossed with rib type design on both sides, front side vertical and back side horizontal and spot welded including hold fasts of (15×3mm), M.S. oxidized fittings such as butt hinges sliding door bolts, handles, tower bolts etc. complete in all respect as per drawing and specifications including applying priming coat of approvedsteel primer 31 11.10Conducting water intake test in test holes under pressure for determining permeability before or after grouting including cost of equipment and water etc. complete 32 Earth work in excavation in foundation trenches or drains including dressing of sides & ramming of bottoms , lift up to 1.5 m including taking out the excavated soil & depositing & refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within lead of 50 m : all kind of soils 33 11.9Grouting of drilled holes minimum 35 mm dia with or without packers with cement/ clay and or chemicals (in the form of slurry with water) in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weight of ingredients excluding chemicals to be considered ) with a working pressure upto 15 kg/Cm2 (Dry cement consumption) 34 Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level: M10 grade nominal mix (with graded stone aggregate 20mm nominal size (P.C.C. in foundation) 35 16.33Exploratory vertical drilling of bore holes 150 mm dia through all kind of soils with the adequate / suitable equipments, tools and tackles for depths mesured below existing ground level including mobilization, setting up boring rig, shifting of rig from 1 bore hole to another and demobilization of the same 36 Random Rubble Stone masonry for superstructure above plinth level one storey height above 30 cm thick walls in: cement sand mortar 1:6 37 16.32.3Boring NX dia (54.7 mm dia), hole with diamond coring bits including taking out of core and arranging etc. core in proper order in core boxes including cost of core boxes. as per relevant I.S. code of practice. These rates are including Mobilization & demobilization of Rig. In sand stone and harder variety of lime stone 38 Filling available excavated earth ( excluding rock) in trenches ,plinth side of foundation etc. in layer not exceeding 20 cm. in depth , consolidating each deposited layer by ramming amd watering including lead up to 50 m and with all lift 39 5.1.3Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum 40 Brick masonry in foundation and plinth with bricks of class designation 75 in: cement mortar (1:6) (1 cement : 6 coarse sand) , add extra for superstructure upto third storey 41 10.1.1Side shuttering including propping etc. complete (to achieve finish F 2 for :Block joints of foundation stilling basins buckets, aprons etc. (non -suspended horizontally laid massconcrete) 42 Providing and laying in position specified grade of cement concrete for RCC structural element upto floor three level including curing , compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of shuttering , centering and reinforcement for: Beams, suspended floors, roofs, girders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircase and spiral staircases : M20 grade nominal mix/design mix Desc/Location Nos L B H 43 9.8.3Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm 44 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of column etc up to plinth level 45 9.6.4Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm 46 P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto floor three level .: Hot rolled deformed bar (IS : 1139) 47 7.1.2Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:4 48 PLASTER (Ceiling) 6 mm thick. Cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) 49 8.13.2Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sandmortar 1:4 50 PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. 51 5.9.1Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respectNot exceeding 15cm 52 Painting with enamel paint of approvd brand and manufacture to give an even shade : Two or more coats on new work 53 18.17.2Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 54 Granding for roof water profing treatment with cement motor 1:4 (1 cement : 4 coarse sand) 2 inch thick 55 18.28.1.2Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458- 2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 56 Polished Blue kota stone flooring Skerting, Laid over 20 mm thick base of cement mortar 1:4 and jointed with Grey cement Slurry to match of the Shade of the Slab including rubbing and polishing complete for area of each slab from 2001 to 5000 sq. cm. 25 mm thick slab 57 11.19Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge 58 Providing brick kharanja in cement sand mortar 1:4 in square pattren over roof of ground floor (75 mm to 100 mm thick avarage) Add for if cement mortar 1 : 4 is used instead of lime sand mortar 1 : 2. 59 18.50Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/ brushing including chiseling and removing leached lime deposit and disposing off all the waste materialoutside adits in specified location as directed etc., complete with all leads and lifts. 60 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish 20 mm thick Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. 61 9.8.4Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sandmortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm 62 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4 ralthal, stone kharanja, lime terracing 90 mm avarage thickness [as per JAIPUR PRACTICE] with ceiling pointing in cement sand mortar 1:3 per specification for span:above 3.00 metre and upto 3.30 metre. 63 10.1.3Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 64 Providing and fixing T-iron frame for doors windwos and ventilators of mild steel tee-setions, joints mitred and welded with 15x3 mm lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 200 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butts hinges and screws and applying a priming coat of approved quality 65 10.9.2.2Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leadsand lifts using. Tor or ribbed bars (IS :1786-1985) 66 window:Providing and fixing Ms sheet double leaf doors shutter in angle iron frame 35x35x5 mm suitabilly digonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of engineer incharge. M.S. Sheet 20 SWG 67 10.9.1Labour charges for steel reinforcement including bending, binding, and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts. 68 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5 mm siutabilly diagonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chokhats: including two coats of anit-corrosive red oxide primer paint. M.S. Sheet 22 SWG 69 10.10.2Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc. 70 Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3 with suitable screw at not exceeding 150 mm distance 71 5.8.1Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicabletaxes and levies etc. complete in all respect Earth / Soil 72 Providing and fixing square bars or other flat welded to window ventilators etc. 10mm x 10mm 73 5.18.2.2(ii)Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of. at least 98% of Standard Proctor s density 74 Polished blue kota stone flooring skirting laid over 20mm thick base of C.M. 1:4 and jointd with grey cement slurry to match the shade of the slab including rubbing & polishing complete: for area of each slab from 901 to 2000 sqcm (a) 25mm thick slab 75 5.9.2Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respect Not exceeding 20cm 76 Providing & fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 77 5.10.1Beyond initial lead of 50 m & upto 250 m 78 Finishing wall with water proofing cement paint of approved brand & manufracture and of required shade to give an even shade including all scafolding new work (three or more coats) 79 5.30Supplying and laying sand of grade as per design requirement in required profile including all lead & lifts.This item is to be used only for laying filter / inverted filter 80 White washing with lime to give in even shade including all scaffolding on new work (three or more coats). 81 5.31.2Supplying and laying aggregate in layers and profile as specified including all leads & lifts.This item is to be used only for laying filter / inverted filterBroken ballast 20 to 40 mm size 82 P & F rigid PVC pipe (IS 4985 Mark) Class 2nd / (4 kg / sqcm) approved quality / Make including jointing the pipe with solvant cement rubber ring and lubricant 110 mm dia. 83 11.14Prepration of old masonry surfaces before laying of further masonry or concrete over it by cleaning the surface and mortar joints with brushing and raking finally, washing by compressed air & water under pressure 84 PVC bend 110 mm 85 37 mm thick shotcrete by wet mix process, applied with compressed air gun after chipping of defective concrete / masonry, racking the joints, cleaning of surface thoroughly with wet sand blasting after fixing of 9 gauge good quality rust free welded mesh of size 50 mm x 50 mm in TWO layers with anchors / clamps. After racking the joints clean the surface thoroughy by wet sand blasting, anchor the first layer of welded mesh in position and apply 15 mm cement concrete (1:2:1) by pressure gun and after hardening of first layer, anchor second layer of welded wire mesh, apply 22 mm thick cement concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively. 86 Pointing on stone masonry in lime sand mortar 1:2 (1 lime putty : 2 sand) : Raised and cut pointing 87 11.18Add extra over item No. 16 &17 for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level (upward or downward) 88 P & F unplasticized poly choride (UPVC) SWR pipe fitting type B for sciland waste discharge system ( IS : 13592: 1992 marked) of approved quality / make 110mm dia 89 12.30.3Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) Tefloncladded 90 P&F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS : 2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : size530x410 mm 91 12.40Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber sealinsertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 92 P & F WVC wash basin (Ist quality, I.S. : 2556 mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. pillar cock (IS : 8934 mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 450 mm x 300 mm 93 12.38Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete. 94 P & F G.I pipes (internal work) with G.I. fittings (IS:1239 mark) & MS clamps including cutting and making good the walls and floors : Exposed on wall A (i) 15 mm dia nominal bore 95 5.28.1Watering of earth including cost of carriage of water when source of water is up to 1 Km 96 Painting with enamel paint of approvd brand and manufacture to give an even shade : One or more coats on old work 97 12.39Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 98 P & F PVC storage tank (IS : 12701 marked indicating the BIS license No), of approved make with cover, 25 mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design : 300 litre capacity. 99 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height 100 P & F stop cock (IS : 8931 mark), superior quality & of approved make : brass 400 gm. 15 mm nominal bore 101 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.upto1.5m height 102 P & F looking mirrors with P.V.C. frame of approved (Atul, Modi Guard , Saint Gobin or equivalent) size 500 x 400 mm 103 18.13Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material 104 P & F flush cock/flush valve (IS 9758 mark) for WC of approved quality make : CP brass half-turn exposed 25 mm nominal bore. 105 12.37Oiling and greasing of Crest radial gates,Vertical Gates and Intake Service well Gates of Dam including all charges of man and material complete, which include cleaning of wire rope with petrol / diesel and applying Cardium compound to wire ropes, oiling & greasing etc complete as per direction of Engineer-in-Charge 106 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick insider plaster in cm 1:6 , finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr. inside size 300 x 300 mm depth up to 0.5 m cement cover with frame. 107 12.4Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator includingcost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tarepoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. 108 Construction of soakage well in all types of soil of approved drawing, top 90 cm. Portion in 450 mm thick masonry with cm 1:6, 80 mm thick stone slab covering, jointing of slab in cm 1:3, Ralthal, Kharanja 40 mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth with in a lead of 50 mtr. inner dia 90 cm & 10 to 12 mtr deep 109 11.13Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete. 110 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other lightshades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flushpointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category-A : Kajaria, Jhonson, Somani make 111 12.52.1.11Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb type of Size 75mm 35mm x 10 mm 112 Add extra over item No 7.6.1 and 7.6.2 for using 400x400mm size MAT finished tiles inplace of 300x300mm size 113 12.52.1.9Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb with brass clading type of Size 100mm 45mm x 15 mm 114 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. doors 115 12.49.2Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Materialfor vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm 116 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded incement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, ormetal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steelhandles and peg stay etc. as required.windows sidehung(openable) 117 5.33Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts 118 Distempering with oil bound washable distemperr of approved brand and manufacture to give an even shade including all scaffolding : old work (one oe more coats) including scrapping surface and necessary repairs (a) colour change 119 12.36Operation of vertical / radial gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer in-Charge, by providing sk illed & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam 120 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and includingscrapping and priming coat with cement primer 121 5.2.2Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Hard rock not requiring blasting 122 P & F bib cock (IS : 8931 mark), superior quality of approved make : Brass 400 grm, 15 mm nominal bore 123 18.1.2Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick 124 P&F sand cast iron (S.C.I.) Pipe (IS:1729 mark) of approved make in wall in floor with MS holder bat clamps in 10X10X10 cm. M15 grade concrete block joints filled with CM 1:4 with spun yard including cutting holes and making good the wall.150mm dia. 125 17.5.2Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 126 P&F SCI fittings (IS1729mark) in CM 1:4 spun yarn150mm w/o door Bend 127 5.2.3Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Phylite & other hard rock requiring nominal blasting 128 spray painting with flat wall paint of approved brand and manufacture to give an even shade : two oe more coats on new work including priming coat of distemper primer of approved brandand manufacture 129 11.2.1Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drillingincluding cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.Up to 5 m. depth 130 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 131 11.2.2Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.From 5 to 10 m depth 132 S&Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steelenclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure A attached with this BSR . 32 A, Four poleF following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according toIS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 133 2.9.2Cement OPC (in bags) 50 Kg in weight. As per IS 1489 and IS 8112 (excluding cost ofempty begs). 134 S&PP & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSRroviding & Fixing of ISO certified company made off load change overswitch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in thefollowing rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 A, Four poleFfollowing sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 6.4 mmthick 135 10.2Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 136 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure Aattached with this BSR 9 mm thick 137 11.1.1.1Drilling holes of 35 mm diameter for anchor rods.Upto 1.50 m. depth 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimumphase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR (a) 6 Amp to 32 Amp rating 139 5.35.3Supplying stone, spall and laying R. R. stone pitching, hammer dressed with packing ofvoids from small stones including all lead & lifts, in required profile of 23 cm thickness ( 5 % thickness tolerance) 140 Providing corrugated G.I. Sheet roofing fixed with G.I.J. or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60o) & excluding the cost of purlins rafters and truses, for class of sheets :1.60mm thick 141 11.1.2Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete 142 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Triple pole MCB 50/63 A rating 143 11.1.3Supply of Tor steel anchor bars of required diameter, length and shape at site of work complete. 144 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR (c) Double pole MCBS of 50 AMP to 63 AMP 145 12.7Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting ofhoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 way Metal door (single phase) 147 12.1.1Design, drawing, fabrication, supply, erection, testing and commissioning of Embedded parts consisting of sill beams, vertical tracks, vertical seal tracks, sealing frame, guide tracks/rails, wall plates, seal seats, anchors, anchor girders, yoke girders, tie flats, trunnion supports, rope and pulley supports etc. and any required necessary item, with all accessories as per relevant IS code, for all type radial gates/ Vertical lift fix wheel type sluice and Canal gates/Stop log gates including cost of all materials, machinery, labour, cutting,aligning, anchoring, welding, finishing, cleaning, tools and tackles, applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thicknessof 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., including packing & forwarding, transportation charges complete item, as per specifications and approved drawings 148 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (metal / Glazed )Distributio board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR 12 way Metal door (single phase) 149 18.49Under water videography of dam body & its appertunance i.e gates, under sluice, emergency gate grooves clearly showing location defect area or area of interest indicatingcondition from all possible angles and special focus on damaged portions complete in all respects upto the satisfaction of Engineer in charge. The work also includes supply of three sets of video in digital form and a depth wise report prepared in hard copy 150 Providing & fixing in position frame made out of MS angle (riveted or welded) finished with two coat of red oxide and enamel paint of following size as required 38*38*6 mm 151 12.8.1Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle, gate positionindicator, plumber block, couplings with all required accessories for operating Head/cross/escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts,including packing & forwarding, transportation charges for structural steel components and other materials. 152 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. systemlumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing 153 5.15.1.1Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all typessoils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 154 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole 100/300 mA sensitivity 40 A rating 155 7.1.3Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation includingcuring with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 156 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulationPVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parametersof product / work refer Annexure A attached with this BSR 1 *2.5 sq.mm 157 9.3.1Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing withrendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher brokenstone aggregate of maximum size upto;(For mix design Cement content considered 420 kg/ cum of concrete) 150 mm 158 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 1*6.00 sq.mm 159 7.10.2Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materialsincluding curing etc. complete. In cement sand mortar 1:4 160 Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron crosshead and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached with this BSR. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm 161 5.26Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. ifrequired including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete 162 Add extra over item No. 10.25 for providing and fixing CGI sheets in curved roofing 163 8.2.1Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm 164 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discomsstandard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 165 10.1.110.1 Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility ScaleSolar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR,showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed towithstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of more than 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in stringlevelmonitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive.The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.10.1.1 Solar panels up to 10 KW at a single location. 166 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure Attached with this BSR 30 Sqmm of (6+1) 2.59mm (Weasel) 167 16.12Hire charges of DGPS instrument with operator and staff for bench mark shifting, topography survey, command area survey, canal survey, dam survey etc. and collection ofdata, plotting the details and preparing digital map of area in layers, and developing contours where ever required as directed by engineer in charge; including supply of detailed drawingsin appropriate scale in soft copy & three sets of Hard copy complete in all respect. These rates are including all types of taxes applicable 168 Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR 169 16.14.1.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, develo ping L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) L-section of Dam/ Canal (ii) InPlain area - Levels for L-section to be taken at interval 30 meter. 170 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 2 LED Tube shape fixture for single rod 171 16.14.2.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, developing L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) X-section of Dam/ Canal(Total length of X-section shall be measured) (ii) In Plain area - Levels for X-section be taken at interval 5meter 172 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lidsuitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 173 16.10Grid survey at interval of 30 x 30 meter to conduct submergence survey with TS / DGPSinstrument and prepare 0.50 m interval contour plan and superimposing over khasra map including all ancillary works as described in specifications and conditions of contract. Note: Khasra map will be provided by Department Marking of existing FRL, MWL, MDDL contours and dam alignment. Prepare area-elevation and storage -elevation curves andtables. 174 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing 175 16.6.1Digitization of Jamabandi and providing excel sheet to the department Note: Jamabandi Register will be provided by Department 176 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ 177 16.6.2Digitization of Khasra map with details in layers and providing soft copy (acad file) Note: Khasra map will be provided by Department 178 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter& Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults,UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturershall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ wo rk , refer Annexure A attached with this BSR . 50 to 82.5 kva 179 5.10.4Add extra for each subsequent lead of 1 km or part there of beyond 5 Km 180 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr) 181 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii - Medium point (upto 6 Mtr) 182 11.5.1Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 183 Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height.In flats, tees, angles and channels. 184 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii - Long point (upto 10 Mtr) 185 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988)accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy /Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :on board 186 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 40A rating 187 P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 188 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirementslaid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 189 Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR . 190 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attached with this BSR 191 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI>70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 watt 192 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 4.8 mm thick 193 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brassterminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR 194 providing of 18mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 195 Chair type 7 {Revolving chair medium back, support backrest symmetrical lumber support, back cover mesh fabric) (inclusive all taxes) 196 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 197 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up theinterstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&Hspecification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete : Crusher broken Grade II (63-45 mm) 198 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specificationincluding all material, labour, machinery, lighting, guarding and maintenance of diversion 199 Chair type 4 {chair type with arms,frame type 4 legs,castors without (inclusive of all taxes)} 200 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fineaggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuousoperation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour,machinery, lighting, guarding and maintenance of diversion. PCC M-25 201 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be rovided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow raceability/authenticity. Fixture shall be IS 10322 Complianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures . (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted . All as per approved by Engineer In charge . for additional technical parameters of products/works . High Power LED Flood 202 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S tube 203 Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 4 meter 204 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work . Double arm overhang 205 providing of 24 mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 206 Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, inte gral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM must have type test certificate for wind tunnel test for high mast fixtures , complete in all respect .All asper pre approved by Engineer in charge ,for additional technical parameters of products/work. 16.0 Mtr HM(in 2section) 207 Labour charge for removing old wire ropes and fixing of new wire ropes with all accessories and T&P etc complete 208 oiling & greasing of gantry crane on Parbati Dam Which includes complete Removal of all old worn out & broken down parts, cables, connections etc complete checking of all copper wiring, all wiring & connections control panel , all switches etc complete with all material , labout, T&P and lead and lift complete in all respect 209 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approvedbrand or manufacture 210 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. : 80mm thick 211 Table type 3 (storage provided one side,length of table top-1200 mm, depth of table top-600 mm) 212 Providing sofa set(Frame covering fully upholstered, Total No of seats in sofa set -4, covering material for seat and back rest-leatherite) 213 Table type 5 (seating capacity - 8 seater, width in mm -1200, Length in mm - 2400mm, shape of table top Rectangular , height in mm - 750 mm ) (inclusive all taxes)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
14.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
15.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
16.
Housing Urban and Rular Development #10191469 AOC
Furnishing Work Of Classrooms, Library And Laboratory, Equipments And Miscellaneous Work For The New University Campus Of Binod Bihari Mahato Koyalanchal University, Dhanbad- 1 Supplying Metal Exhaust Fan 300 mm Sweep-Supplying, erecting and testing of approved make 300 mm sweep Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including frame bolt/ Anchor hole fastners etc, complete finished of a as required. 2 Wall Demolition- Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 3 Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 4 Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5 Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 6 Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 7 Door Frame- Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile C - Fixing with adjustable lugs with split end tail to each jamb 8 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. 9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. 10 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.-Granite stone slab colour black, Cherry/Ruby red-Area of slab over 0.50 sqm 14 Sink- Supplying fitting and fixing white glazed fires clay sink of approved make with overflow arrangements supported on C.I. Or R.S. Painted bracket 40mm. Dia C.P. Brass waste with C.P. Brass chain and rubber plug 40mm dia P.V.C. Waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Size-600 mm x 450 mm x 250 mm ) 15 FULL HEIGHT WOODEN PARTITION WITH PARTLY GLAZING- Providing and fixing partitions made of 50 mm x 50 mm pine wood / 2nd class teak wood @ 600 mm c/c both ways with the help of Fasteners/Screws etc. to achieve desired strength. Providing & fixing Comm. grade 12 mm thick commercial Pty board on the frame on both the faces i/c exposed side edges of Frame & 1.0mm thk Laminate on both outer faces and exposed side edges of ply as per the directions. Partition shall also be provided with 8 mm thick clear float glass of approved size with Polished Edges of approved brands in Wooden Partition Openings as required, fixed from all four sides from both ways inside partition openings with 10mm.tk. T.W. beadings/12 mm thick MDF Board Lipping/D-Buttons of design as per approval and direction at site. Etching / Etching Film (50 Microns) is to be provided as per approved pattern on 8 mm thick clear float glass. All wooden exposed surfaces shall be melamine polished in approved shade and texture finished as per the directions and satisfaction of Engineer In charge, compelete.This work will 16 Frosted glass sheet of nominal thickness 4 mm- Providing and pasting frosted film on glass work including all materials tools, plants and labour complete as per the directions of the Engineer-in-charge. 17 Supply & laying of PVC insulated and sheathed 1.1 kv grade twin twisted 1.5 sqmm cu flexible wire for speaker. 18 Providing & installation 1.5 Tr. 5 Star split A.C (Inverter Type) I91391-part-1 19 Copper refregerant pipe-Providing & installation Copper Tube of size 5/8 for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation 20 Providing & installation 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280V 21 Providing & installation Drain Pipe for AC 22 Non Schedule 23 * PROVIDING AND SUPPLYING MODERN DESIGN RECEPTION DESK IN ENGINEERED WOOD MAKE THE PRODUCTS UTILE AND A DELIGHT.TIMELESS DESIGN THAT ELEVATES YOUR OFFICE SPACE STRUCTURE OF SPACIOUS RECEPTION DESK,TABLETOP OFFERS YOU A GENEROUS LOOK FOR WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 1800 MM(L)X 600 MM(D)X 750 MM(H) WHICH GIVE MORE SURFACE AREA FOR WORK ,TABLE TOP MADE OF25MM THICK ALSO TABLE TOP BASED ON SIDE PANELS MADE 18MM THICK PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST. * COMBINATION CONSTRUCTION OF RECEPTION DESK ABOVE TABLE TOP 18 MM THICK COUNTER TOP TO TABLE TOP HEIGHT IS @ 300MM ,OVERALL RECEPTION DESK HEIGHT IS @ 1050MM WITH COUNTER TOP,TABLE TOP MADE 25 MM THICK PRELAM PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK PVC EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXED WITH HOT MELT GLUE.ALONG WITH 18MM THK ADDITIONAL MODESTY PANEL SIZE IS 1350 MM (L) X 700 MM (H) MADE BY EXCLUSIVE FROSTY WHITE COLOUR WITH EPIC DESIGN & LOOK.1 MOBILEPEDESTAL (2 DRAWERS + 1 FILING CABINET )SIZE IS 450 MM(L)X 450 MM(D)X 725 MM(H) IN PROVIDED WITH CENTRAL LOCKS FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING & PEDESTALS MOVE ON NYLON CASTORS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST 24 PROVIDING AND SUPPLYING * MEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 580MM(L)X 670MM(D)X1110MM(H) ,*THE CHAIR MADE OF FULL UPHOLSTERY IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : AMREST IS HAVING TWO ADJUSTMENT HEIGHTS (UP & DOWN) .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM. SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 480MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1110MM & MINIMUM HEIGHT IS1010MM* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650MM NYLON BASE WITH SMOOTH CASTORS . 25 PROVIDING AND SUPPLYING 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION,THREE SEATERTYPE WAITING AREA CHAIR - MATERIAL : STAINLESS STEEL SIZE 1820MM(L)X 690MM(D)X 790MM(H) COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 26 Supplying of Portrait/Landscape Not applicable Fabric Pin Up Notice Boards(Fabric Pin Up Notice Boards 3 X 6 FT GREEN),Specification-Width of Board in mm:900 mm,Colour(Front/ Display layer):Green,Height of Board in mm:1800mm,Rear panel material of Board:Laminated sheet,Overall pinability depth ofBoard in mm:9 millimeter,Core material thickness inmm:9 millimeter 27 PROVIDING AND SUPPLYING COLLEGE DESK TOMKINS MATERIAL : PRELAMINATED PARTICLE BOARD WITH M.S BASE UNIT SIZE : 590 MM(L) X 1090 MM(D) X 830 MM(H) PER SEAT SIZE- 590 MM X 375 MM X 450 MM/ONE SEATER DESK SIZE :1090 MM(L) X830 MM(H) COLOUR : AVAILABLE ON REQUEST/FINISH : EPOXY POLYESTER ,* PROVIDING & SUPPLYING TWO SEATER COLLEGE DESK TOMKINS COMBINATION OF THREE ROWS FIRST , MIDDLE AND LAST SCRATCHPROOF EASY WIPE TOP / DURABLE ,STRONG & SAFE,UNDERSTRACTURE MADE OF MAIN FRAME MDE OF CRCA POWDER COATED IS GRAD:304 M.S BLACK POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) EPOXY POLYESTER COATING.* TABLE TOP & MODESTY PANNEL MADE IN 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS.CHAIR WITH GAS LIFT ,A). BACK FRAME: 1.2MM COLD ROLLED STEEL/B). BACK BOARD: 10MM PLYWOOD, NO CUSHION C). SEAT BOARD: 15MM PLYWOOD, NO CUSHION/D). TIP-UP SYSTEM: SPRING MECHANISM E). 2. LEG: COLD-ROLLED STEEL, FIXING ON THE FLOOR BY SCREWS, 80 X 35 X 1.5MM THICK OVAL TUBE, BLACK POWDER SPRAYING.* THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST 28 Supplying of Material & Subtype Engineered Wood Table Top Material Engineered Wood Finish Matte Colour & Colour Family Brown - Classic Walnut Dimension (W)550mm X (D)550mm X (H)1200mm Size Compact Assembly Type Knock Down (Obelisk), 29 Suppling of Writing Board ( 4x10 Non-Magnetic) of material Top Surface materials (Used for white boardsurface)-Porcelain,Top surface material thickness -0.7 mm to 0.8 mm,Frame material -Anodized extruded aluminum alloy hollow section conforming to IS 733 (With latest amendment),Frame wall thickness-1.2 mm,Frame section front -20 mm,Frame section side -16 mm,Core material-MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness -9 mm as per Department incharge 30 Supplying of 14 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 8850 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 8850 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST, * CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST, 31 Supplying of * HIGH BACK 360° DEGRE REVOLVING CHAIR SKU : MARVEL/HB/ECO ,* ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1380MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM . * ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) , SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1380MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 32 Supplying ofMEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1125MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM .* ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) ,SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1125MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 33 Supplying of Tte Mild Steel Pipe of diameter 19 mm and wall thickness 16gauge. Classroom Chairs, tte,Thickness-2mm to 45mm,Material-Mild Steel Weight-Depends upon the size,Outside Diameter-0.80 Inch to 36 Inch 34 Supplying of 1-Bay Sprocket Chain Drive Mechanism MobileStorage Compactors,Material-Mild Steel Product Type-1 Bay,Height -7 ft,Storage Capacity-50-80 kg Usage/Application office, Home, Hospital, Store Room, Warehouse 35 Supplying of -- Movable File StorageSystem (Compactor) 1-Bay Mechnized Drive Type(COMPACTOR 2 ( 04 BODY)) 36 Supplying of Methodex MS1-6MCMETHODEX(Methodex MS1-6MC),Accutec Mobile Storage System,Material SS,Usage/Application-Warehouse Height-8-10 Feet,No of Layers-5 37 Supplying of : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 38 Supplying of : PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK . * PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 39 Supplying of* HIGH BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 590MM(L)X 505MM(D)X1280MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING . * USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * MECHANISM : KNEE TILT MECHANISM . * ONLY SEAT SIZE IS 505MM(L)X 505MM(D)X610MM(H) & THE BACK SIZE IS 590MM(L)X 710MM(H) SEAT MAXIMUM HEIGHT IS 610MM & MINIMUM HEIGHT IS 510MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1280MM & MINIMUM HEIGHT IS1180MM * GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650 MM CHROME BASE WITH SMOOTH CASTORS . 40 Supplying of* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 570MM(L)X 500MM(D)X940MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE . DETAILS : * ARMS : PADDED ARMREST. * USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED. * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * ONLY SEAT SIZE IS 570MM(L)X 500MM(D)X475MM(H) SEAT HEIGHT IS @ 940MM & BACK HEIGHT IS @ 475MM . * FIXED CANTILEVER CHAIR . * BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 41 * SUPPLYING AND PLACING FIVE SEATER (3+1+1) EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 3 SEATER- 1905MM(L) X890MM(D)X 870MM(H)SOFA SIZE IS 1 SEATER -(W)960mm X (D)890mm X (H)870mm ,WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME. * COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 28 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 50MM THIK,40MM THICK BACK FOAM HAVING 20 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 20 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BLACK-EERIE BLACK-COFFEE BROWN,BROWN-BURNT UMBER COLOUR, IT COMPLEMENTS THE MODISH LEGS ARE MADE BY ROUND SHAPE IN PVC MATERIAL. 42 Supplying of Material & Subtype Solid Wood - Beech Wood Table Top Material Clear Glass,Frame Material Solid Wood Leg Material Solid Wood,Finish Matte Colour & Colour Family Brown - Walnut,Dimension (W)1130mm X (D)630mm X (H)410mm,Number Of Recliners 1 Number Of Reclining Positions 3,Size Standard (HOPPER/CT), 43 Supplying of6 SEATER Rectangular MEETING TABLE DURIAN MODEL SMART/CON/6FT MADE OF PRELAMINATED PARTICLE BOARD WITHSLANTLEGS50X50 MM MS UNDERSTRUCTURE IN POWDER COATING 2TOP MADE OF25MMTHICK PRELAMINATED PARTICLE BOARD IN FROSTY WHITE COLOR WITH MAIN TABLE SIZE1800MM(L)X 1050MM(D)X 750MM(H) (SMART/CON/6FT/A), 44 SUPPLYING & PROVIDING CAFETERIA CHAIR SIZE IS 381MM(L)X 419MM(D)X839MM(H) A COMBINATION OF SYNTHETIC FIBER WITH STAINLESS STEEL MAKE THE PRODUCTS UTILE AND A DELIGHT, THE COMPLETE STRUCTURE SHALL BE MADE UP OF 20% GLASS FILLED BLOW MOLDED HIGH-DENSITY POLYETHYLENE ANDIS,THE FRAME STRUCTURE SHALL BE SUPPORTED BY ( 2 STRAIGHT + 2 SLANT ) FOUR LEGS.THE TUBULAR WELDED FRAME IS MADE FROM DIA2.22 +/- 0.03CMX 0.12+/- 0.0128 CM AND 3.5+/- 0.03 CM X 0.12+/- 0.0128 AM STAINLESS STEEL 202 GRADE TUBE & THE TUBE ARE BUFF POLISHED TO GIVE SHINY FINISH.SEAT AND IN BACK GIVEN HANDLE TO HOLDARE MADE OF INJECTION MOULDED HIGH IMPACT STRENGTH POLYPROPYLENE POLYMER COMPOUND WITH INDOOR GRADE UV RESISTANCE AND PRESSED FITTED WITH LEGS.THE CHAIR IS EASY TO STORE WHEN NOT IN USE, SINCE YOU CAN STACK UP TO 6 CHAIRS ON TOP OF EACH OTHER. (COCO/SUR). 45 SUPPLING OF METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1830MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET.HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, FITTED WITH MS BODY LOCK & HANDLE. WITH 2 NUMBERS OF GLASS DOOR SHUTTERS , THE GLASS USED SHALL BE 4MM THICK CLEAR. UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 30 KG MAXIMUM.EACHRACKSHALLBEPROVIDEDWITHSTIFFENERATBOTTOMFOR STRENGTH.THE ENTIREBODYPANELAND SHELF SHALLBEMADEOF HIGHYIELD STRENGTH,THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY 46 SUPPLING OF DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 750MM(D)X 750MM(H) 36MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITHWENGE FINISH, USING HOT MELT GLUE TO FIXING 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 25MM THICK.*PROVISION OF SIDE RUNNER OF SIZE IS 750MM(L)X 450MM(D)X 760MM(H) ,( CONSTRUCTION IS FROM RIGHT SIDE OF SIDE UNIT TOP BASED ON FIXED PEDESTAL WITH SS STUD OF GRADE 304, ON TABLE TOP PVC GROMENT HOLEFOR WIRE MANAGEMENT .*FIXED PEDESTAL OF SIZE450MM(L)X 450MM(D)X 650MM(H) PER DRAWER HEIGHT IS @ 136MM, FILLING DRAWER HEIGHT IS @ 300MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 47 SUPPLING OF* CANTILEVER CHAIR SKU : 70011/CN/A, * ALL OVER SIZE IS : 590MM(L)X 490MM(D)X980MM(H) , *THE CHAIR MADE OF FULL FABRIC INBLACK COLOUR . IT WILL COMES INFINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS : FIXED ARMS P.P. CONNECTED WITH SEAT AND BACK .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32(±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* BASE : M.S POWDER COATED TUBLAR FRAME OF CATILEVER TYPE . THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. 48 SUPPLING OF OFFICE DESKDESK STRUCTURE OF L SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL 18MADE OF MM THICK . *PROVISION OF SIDE UNIT OF SIZE IS 900MM(L)X 450MM(D)X 750MM(H) ,(COMBINATION CONSTRUCTION WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP, LEFT SIDE TABLE TOP BASED ON A 18MM THICK SIDE PANNEL ENGINEERED WOOD & FROM RIGHT SIDE UNIT HAVE 2 SLIDING DOOR + 1 FIXED SHELVE . *SIDE UNIT SIZE900MM(L)X 450MM(D)X 750MM(H), IN PROVIDED WITH LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF SIDE UNIT IS 18MM THICK ALONG WITH FECIA OF SLIDDING SHUTTERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST . 49 SUPPLING OF * FIX CANTILEVER ,* ALL OVER SIZE IS : 595MM(L)X 510MM(D)X875MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 500MM(L)X 510MM(D)X455 MM(H) & THE BACK SIZE IS 440MM(L)X 595MM(H) , BACK HEIGHT IS @ 440MM .* BASE : 4 LEGS METAL POWDER COATED* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 50 * PROVIDING AND SUPPLYING PENTA WORKSTATIONLSHAPE SINGLE SEATER UNIT NON SHARING IN COMPLETELY KNOCK DOWN CONDITIONS WITH AN OVERALL SIZE 1500MM(L)X 600MM(D)X 1200MM(H) THAT IS TO BE ASSEMBLED AT SITE. THE WORKTOPSHALLHAVETHESIZE1490MM-1490MM (L) x 592(D) MADEUPOF25MMTHICKPRE- LAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST . OF IS LEVEL WITH APPROVED LAMINATE AND FINISH AS PER APPROVED SHADE. * THE PROFILE OF THE TOP SHALL BE IN RECTANGLE SHAPE AND THE EDGES SHALL BE SEALEDWITH 2MM THICK THIN STRIP OF IMPERMEABLEPVCTHAT IS CUT TO FIT THE SIZE OF BOARD PANEL AND DULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THE TOP TRIM, TOP BAR, MID BAR, VERTICAL BAR, RACEWAY, SKIRTING SHALL BE MADE UP OF ALUMINIUM EXTRUSIONS (PRE-TREATED)AND DULY POWDER COATED WITH POLYESTER POWDER COATING 40P-60PTHICK . THE TRIMS SHALL HAVE THE SIZE 67MM X 19MM WITH 1.5MMTHICKCOVERED WITH DIE CAST END CAPS ON JOINTS 2 WAYS,3 WAYS& 4 WAYS(L-COVERFORCORNER,T-COVERFORMIDDLESECTIONWHEREVER REQUIRED).THEALUMINIUMRACEWAYSHALLBESITUATEDBELOWTHEWORKTOPWITHAN OVERALLSIZE149MM(H)X60MM(D)WITH1.4MMCOVERTHICKNESSAND2MMBACK THICKNESS AS PER REQUIREMENT OF INLAYING THE ELECTRICAL MANAGEMENT AND CARRYING THE WIRE HORIZONTALLY. *THE EXPOSED VERTICAL AND HORIZONTALFACES OF THE FRAMES SHALL BE SNAPFITTEDWITHTRIMS.THERESHALLBESOFT-BOARD(WITHFABRIC)ANDMARKERBOARD PROVIDED AT FRONT OF THE USER. LAMINATED TOP TILE AND BOTTOM TILE SHALL BE SITUATED AT BOTH SIDES OF THE USER AND BELOW THE WORK TOP RESPECTIVELY. THE PARTITION SHALL HAVE CONCEALED WIRE MANAGEMENT CAPABILITIES AND SHOULD BE ENGAGED FOR RESPONSIVE AND SAFE OPERATIONSOF POWER,TELECOMMUNICATIONSANDDATA(LAN)AND HASSEPARATE COMPONENTS FOR ELECTRICAL, DATA AND TELEPHONE CABLES HAVING ADEQUATE CAPABILITY OF BOTH THE VERTICAL AND HORIZONTAL WIRE MOVEMENTS.SLOTS/CUT-OUTS SHOULD BE GIVEN ON RACEWAYSTOFIXALLELECTRICALANDDATAPOINTS.SINGLESIDEDPVCWIRE MANAGER SHOULDBE ENCLOSEDATTABLETOP.ADJUSTABLE LEVELLERSHOE SHALL BE PROVIDED AT BOTTOM OF THE PARTITION TO AVOID SCRATCHESON THE FLOOR.PARTICLE BOARD OF GRADE II OFISLEVEL. * THREE LAYER PRELAMINATED PARTICLES BOARD (WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST .* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 51 PROVIDING & SUPPLYINGFIXING OF TWO SEATER SCHOOL DESK WITH SHELF/STORAGE UNDER DESK WHICH ONE MADE BY CAST IRON,DESK TOP MADE BY 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST,TWO SEATER CLASSROOM DESK CUM BENCH, TOTAL SIZE OF BENCH : 1050MM(L)X 950MM(D)X 760MM(H) DESK SIZE : 1050MM (W) X 400MM (D) X 760MM (H) BENCH SIZE : 1050MM (W) X 310MM (D) X 390 / 760MM (H) BACK SIZE : 1050MM (W) X 150 MM (H),TABLE TOP SHALL BE POLYPROPYLENE CO POLYMER (PPCP).BANDING UNDER STRUCTURE-BLACK 9005 ERW PIPE (AS PER IS:7138) : 25X25X1.2MM SQUARE MS PIPE, OF THICKNESS 1.2MM IN BLACK EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) AT BASE WITH PLASTIC CAPS MADE OF PP COPOLYMER (3530 GRADE) ARE ALSO PROVIDED ON THE REAR FRAMES ADDING MORE AESTHETIC VALUE TO THE PRODUCT. * ADDITIONAL HORIZONTAL SUPPORTS OF M.S. C SECTIONS OF 1.5MM THICK ARE PROVIDED BELOW THE DESK & SEAT.SHELF: 0.8MM THICK POWDER COATED M.S. SHEET BELOW THE DESK & HOOKS ON EITHER SIDE OF DESK IN M.S. ROD OF DIA 6MM.TOP,SEAT AND BACK PANEL: 18MM THICK PRE LAMINATED BOARD WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST.* 52 Suplying of Laboratory Steel Furniture Sidebench with rack and table top of specification,Size of side benches/Island benches (LxWxH):1800 mm X 1800 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 53 Supplying of Laboratory Steel Furniture Island bench with table top Size of side benches/Island benches (LxWxH):900 mm X 1500 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 54 Supplying ofPowder coated Round Classroom Stools Load of 50 Kg of stool of specification:Height Adjustment: Without Hydraulic,Frame and support made of CHROME PLATED MS TUBES,Chair Type:Non Revolving,Type of seating:Only seat,Pedestal base :Aluminium Die Cast 55 Suppling of Over Head Storage delite hi-tech of specification Material of Construction:ISI Marked, three layer Prelaminated particle Board conforming to Grade II Type III of IS 12823/2013 laminated with 0.6-0.8 mm thick lamination conforming to IS 2046/1995 and balancing lamination of 0.5 mm thick on the back side,Number of Shelves (Nos):2 Number of Doors (Nos) -2 ,Height in mm (±10 mm)-750,Depth in mm (±5 mm)-450 56 Suppling ofStainless Steel Name Plates, Monograms, Labels, As per BHEL ,Specifications :Stainless Steel Name Plates, Monograms, Labels, 57 Suppling of Aquaguard RO & UV both SS304 Drinking Water Coolers With Built In Water Purifiction System AquaguardR 58 Suppling ofStainless Steel External Branding Signage Boards, Size 22X6 Feet,Signage Printing-Single size vinyl print ,Material -Stainless steel ,Coating: Gloss or matte,Fabrication Specs-framing with one coat of red oxide & 2 coats of oil paint to avoid rusting 59 PROVIDING & SUPPLYING DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2100MM(L)X 900MM(D)X 750MM(H) 50MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH CLASSIC WENGE BROWN FINISH 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 50MM THICK* PROVISION OF SIDE RUNNER OF SIZE IS 1200MM(L)X 400MM(D)X 760MM(H) ,(CCOMBINATION ONSTRUCTION BELOW TABLE TOP 1 KEY BOARD TRAY IN PVC WITH TELESCOPIC CHANNEL ON RIGHT SIDE IS MOVABLESIDE RUNNERHAVING 1 OPENABLE DOOR WITH 1 FIXED SHELVE, 1 OPEN BOX WITH 1 FIXED SHELVE UPPER SHELVE HEIGHT IS @ 320MM BELOW SHELVE HEIGHT IS @324@ + 3 DRAWERS (2 EQUAL DRAWERS + 1 FILLING DRAWER)PER DRAWER HEIGHT IS @ 184MM, FILLING DRAWER HEIGHT IS @ 303MM HAVE CENTRAL LOCKAND HANDLES WITH CASTORS .* MOBILE PEDESTAL OF SIZE400MM(L)X 530MM(D)X 671MM(H) ,PER DRAWER HEIGHT IS @ 186MM, FILLING DRAWER HEIGHT IS @ 195MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 60 PROVIDING & SUPPLYING* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 610MM(L)X 505MM(D)X990MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORTbackrest support* ONLY SEAT SIZE IS 610MM(L)X 505MM(D)X485MM(H) & THE BACK SIZE IS 610MM(L)X 540MM(H) ,* BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 61 PROVIDING & SUPPLYING OFFICE DESK STRUCTURE OF RECTANGULAR SHAPE .PRIMARY WORK SURFACE OVER ALL SIZE IS 1200MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF 25MM THICK PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL MADE OF 18MM THICK, WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP.*CONSTRUCTION RIGHT SIDE OF TABLE TOP IS BASED ON A FIXED PEDESTAL3 DRAWERS & FROM LEFT SIDE OF TABLE TOP IS BASED ON 18MM THK ENGINEERED WOOD PVC EDGE BANDING PEDESTAL BACK,TOP,BOTTOM & DRAWERS ARE MADE OF 18MM THICK WITH 1 CPU TROLLY MADE IN BLACK METAL POWDER COATED.*FIXED PEDESTAL:L:410MM(L)X 580MM(D)X 750MM(H) ,IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823. 62 Suppling of Material & Subtype Solid Wood - Beech Wood Table Top Material Solid Wood,Leg Material Solid Wood Finish Glossy Colour & Colour Family Brown - Walnut Dimension (W)680mm X (D)530mm X (H)450mm Table Top Thickness 8mm,Size Compact, 63 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 838MM(L)X 305MM(D)X 1676MM(H) STEEL BOOKCASE HAVING 4 DOORS AND K. TYPE OF LOCK: THREE WAYBOLTING DEVICE CONTROLLED BY LOCK, THICKNESS OF MS SHEET USED FOR SHUTTER: 0.7 MM, THICKNESS OF MS SHEET USED FOR SHELF: 0.7 MM, THICKNESS OF MS SHEET USED FOR TOP,BOTTOM, BACK AND SIDES: 0.7 MM, MATERIAL OF HANDLE: CAST BRASS, THICKNESS OF TRANSPARENT GLASS IN SHUTTERS: 4.0 MM, THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 60-80 MICRONIN COLOR GREY-LIGHT GREY. 64 Suppling of 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION DURIAN,THREE SEATERTYPE WAITING AREA CHAIR -NIXON/SS/3 MATERIAL : STAINLESS STEEL,SIZE 1820MM(L)X 690MM(D)X 790MM(H)COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 65 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE) 6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY. 66 PROVIDING & SUPPLYING * FIX CANTILEVER CHAIR PROVIDING & SUPPLYING* ALL OVER SIZE IS : 590MM(L)X 490MM(D)X940MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED.* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 35 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 590MM(L)X 490MM(D)X450MM(H) SEAT HEIGHT IS @ 450MM .* BASE : 2 CHROME LEGS + BACK SIDE BOTTOM CHROME IN METAL . 67 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM). 68 SUPPLYING AND PLACING30 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated ParticleBoards Of Grade-II Type-II Of IS:12823/Latest (for 14 seater rate devided by 30X24} 69 SUPPLYING AND PLACING PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OFSUPPLYING AND PLACING PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK .* PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 70 SUPPLYING AND PLACING* HIGH BACK 360° DEGRE REVOLVINGCHAIR * ALL OVER SIZE IS : 673MM(L)X 508MM(D)X1270MM(H) , *THE CHAIR MADE OF FULL NATURAL LEATHER IN BROWN COLOUR . IT WILL COMES IN MATTE FINSIH EXTRA PADDED DESIGNED FOR MORE CONFIRMT AT WORKPLACE IN CONTEMPORARY STYLE . DETAILS :* ARMS : WOODEN ARMS WITH LETHER PADDING ARM REST ARE FITTED TO THE SEAT & BACK.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT . * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK .BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : MULTI-LOCKING KNEE TILT MECHANISM .SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 500MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1270MM & MINIMUM HEIGHT IS 1219MM* GAS LIFT 80MM TELESCOPIC HAUDRAULIC * BASE : THE PRONG (BASE) IS MADE OF SOILD WOOD WITH POLISHEDAND FITTED WITH 5 NUMBERS. TWIN WHEEL CASTORS (CASTOR WHEEL DIA. 50MM) & 700MM PITCH CENTER DIA (740MM WITH CASTORS) . 71 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood Upholstery Material Leather,Seat Material Leather Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)1140mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 1 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 72 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood,Upholstery Material Leather,Seat Material Leather,Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)2130mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 3 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 73 SUPPLYING AND PLACING Rectangular CENTRE TABLE with Marble Top of 1219mmX711mm,(DAISY/CT (W)1300mm X (D)650mm X (H)450mm),Specifications:Number of storage under top No storage,Top material,Tempered glass,Frame material No frames,Dimension of Top (Length X Breadth, or Diameter) ±20mm,762mmX457mm,Height of centre table ±10mm,410,millimeter,Thickness of top material (+/-2 mm)- 8 millimeterThickness of frame material (+/- 1 mm)-10 millimeter 74 SUPPLYING AND PLACING 14 SEATER oval MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II 75 SUPPLYING AND PLACING 6 Seater Sofa Material & Subtype-Premium Leatherette,Frame Material Solid Wood,Upholstery Material Premium Leatherette,Filling Material Foam,Silicone Fiber,Seat Material Premium Leatherette-Leg Material Solid Wood,Finish Matte,Colour & Colour Family Brown -Coffee Brown Dimension (W)4865mm X (D)960mm X (H)820mm,Seating -Capacity 3 Seater,seating Height 475mm,Size Standard 76 SUPPLYING AND PLACING9 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 4650 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 4650 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST,* CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATESt. 77 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM) 78 SUPPLYING AND PLACING Wooden Acoustic Wall Cladding/Panelling- Providing and fixing in position wood wall paneling of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing/wood veneer as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class 1, BS 476 part 7. The edges of the panels shall be tongued-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install Gel stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontalty using screws and plugs at spacing of 600mm centre-to-centre, Screw the aluminium channel (keel) vertically on channeled G.I stud 600mm 79 SUPPLYING AND PLACINGBlackout roller blind,Specifications-Mounting arrangement profile systems – clicked on hidden mounting clipsTypes of roller blind,Blackout roller blind-Shading solutionSingle roller blind – utilise one layer of fabric (called outer layer Operating mechanism-Side winders (that lock the manually adjustable blinds at different levels with the internal ratchet and tension adjusted by spring inside the tube) 80 Providing and Fixingof Drawers in Brown Finish ,Specification-Material : High QualityParticle board Dimensions (In Centimeters)-H 91 x W 90 x D 44 Dimensions (in Inches)-H 36 x W 35.5 x D 17.5 Primary Material-Engineered Wood as per Engineer incharge 81 Providing and FixingSTAGE - Providing & fixing raised stepped floor (Stage) Consisting ofMS Tabular frame work ofPipe Section (HOT ROLLED/COLD ROLLED) size 50mmx 50mmx2.0mm.tk. duly Painted with one coat of Red Oxide steel Primer, fabricated in module of 600 x 600 mm frame gid (as per Design or as instructed) with support of same section Legs /frame fixed on existing floor from base and raised at height minimum 150mm to max 200mm as required, from Existing floor. Vc providing and fixing 18mm thick heavy duty high density (1450 kg/cum) cement fiber Board fixed by SS. Screw on Horizontal & Vertical Surface on Existing Framework with one coated cement primer on Board and covering Board from top and sides by 2mm thick Vinyl flooring of approved make,colour and texture to be layed and fixed on sub floor smoothly finished and levelled by recommended adhesive cutting fixing and including covered raised portion of Board from all sides etc. complete,suitable for use up to the satisfaction of Engineer- in-charge.Design as approved by Engineer-In-charge. Base ofthe Vertical Legs of M.S. Frame (COLD ROLLED/HOT ROLLED) 82 Providing, fixing & installation MICROPHONE:-Flat frequency response across the vocal range for uncolored sound interchangeable cardioid, supercardioid, and omnidirec- tional cartridges that provide choices for applications Sleek, low-profile design for unobtrusive appearance Balanced transformerless output for increased immunity to noise over long cable runs-Compact Cinema Surround Speaker for Digital Applications:- Frequency range: 50 Hz to 20 kHz • High sensitivity: 91 dB SPL, IW @ 1m (3.3 ft) High power handling capability: 150 watts, continuous pink noise Internal Thermomaster• technology allows for unprecedented high frequency power in a compact, molded enclosure Convenient mounting design supports JBL QuickMountre, OmniMount• or APC multimount brackets Special cabinet shape incorporates 20• angled front baffle SMPTE/lS02969 Curve X high frequency de-emphasisMixer 8 input mono mixer XLR input switchable between mic and line level +/- 15dB gain trim control per input Input 1 is switchable to be pre/post master 24VDC or mains power operation Optional remote VCA/Tone generator/ Muting boards available • Whisper quiet operation 83 Supply, Installation, Testing and commissioning of microphone Delegate unit. 84 Supply, Installation, Testing and commissioning of microphone Chaiman unit, 85 Supply , Installation , testing and commissioning of Factory made 1.4HDMl Cable along with connector (15mtr length) 86 Supply , Installation , testing and commissioning of Factory made VGA along with Connectors.(15mtr length) 87 Supply , Installation , testing and commissioning of Factory made RCA along with Connectors.(15mtr length) 88 Supply , Installation , testing and commissioning 40W power Amplifier of following features:- Rated output wattage - 240W, amplifier output IOOV, 70V and 4-16 ohms transformer isolated speaker outputs, Supply input 0.775 v (OdB) unbalanced, 10k ohms, XLR and phone jack frequency 89 Supply , Installation , testing and commissioning10W wall mount speaker- Supplying, installation, testing and commissioning of 240W power amplifier with following features:- Rated output wattage- 240W, amplifier output 100V, 70V and 4-16 ohms transformer isolated speaker output, Supply input 0.775 v (0 db) unbalanced, 10k ohms, ZLR and phone jack frequency response 50 - 18000 Hz, +/- 1.5 dB, S/N ratio > 105 dB. 90 Supply , Installation , testing and commissioningCONFERENCE CONTROL UNIT, line Output 1 17.5V DC/3a Max.; -34dBV (20mV), line Output 2 17.5V DC/3a Max.; -34dBV (20mV), power Output 50w rMS at 2% THD, 90w Max. inputs 3xMic 0.65mV/4.7kQ Ixaux IOOmV/470kQ Frequency response 60-14,000Hz (± 3dB) 91 Supplying of Material & Subtype Engineered Wood Finish Matte,Colour & Colour Family Brown - Wenge Dimension (W)800mm X (D)384mm X (H)1970mm Size Standard,Style Contemporary,Assembly Type Knock Down 92 Supplying of Powder Coated Extruded Aluminium Sections Hybrid panel based system (combination of sliding & snap fit tiles) Modular Work Stations 93 Supplying of11 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823 94 SUPPLYING AND PLACINGSLOTED ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE)6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY, 95 SUPPLYING AND PLACING : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 96 Providing and fixing e Slimline Tower AC (2 Ton White),Availability of BIS/ISI Mark Certification for Split AC Floor type-Yes,Technology of air conditioner,Non Inverter AC-Nominal Marketing capacity as per BEE Star Rating Label (hint: 1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) (in Ton)-3 BEE Star rating of the product (Central Ministries/Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star (where usage is Limited)or higher Star R NA- Star rating for the capacity of >10,465 Watts (>9,000 kcal/hour) 97 Providing & Fixing 2.0 mm thick homogenous single layered vinyl flooring. The flooring shall be laid in manner to provide comfortable and jerk free surfaces including material, adhesive, scaffloding and lead and lift at all floor level etc. complete as per direction and approval of Engineer-in-charge. 98 Providing & Fixing Wiring for Primary Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insuate copperconductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point With 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Switch with Front plate and metal Box with all Accessroies for users. 99 Providing & Fixing Wiring for Secondry Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with all Accessories. 100 Providing & Fixing Wiring for Primary Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 101 Providing & Fixing Wiring for Secondry Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 102 Wiring for Primary Power point 6/16 Amp Switch-Socket Outlet with 4 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq-mm FR PVC insulated copper conductor Wire. Providing and fixing 1 nos 6/16A Socket controlled by 1 nos 16A switch with front plate and metal box with allAccessories. 103 Providing & Fixing Standing Bathtubs Specifications:Size:1690x800x445/565mm Free Standing Bath Tub with Over Flow & Drain 104 Providing & Fixing Corazzin Garden Patio Seating Chair and Table Set Outdoor Balcony Garden Coffee Table Set Furniture with 1 Table and 4 Chairs Set (Black) 105 Providing & Fixing Reliable Drapes Cotton Plain Door Curtains Reliable Drapes,Cotton GSM Quality-220,Lining included-No, Pack of-1,Length (Ft)-8.5-9,Width (Ft)-3-3.5 106 Providing MattressDimension 1981 mm X 1829 mm,Thickness of Core Layer (Height of Spring) 200 mm,Thickness of Felt (±1 mm) for Bonnell Spring 12 mm,Thickness of Top Layer (±2 mm)-50 mm Thickness of Bottom Layer (±2 mm)50 mm,Type of Spring in Core Layer Bonnell Spring (with cotton felt),Material of Top Layer Visco Elastic PU Foam (Memory Foam) 107 ProvidingCotton Pillow 33 cm x 56 cm (COTTON PILLOW)of Specification-BIS Marking ( For Body Casing fabric )-No Logo Marking-No,type of Logo,Stitched ( Patch Logo ),Agree to provide 108 Providing240 centimeter x C1112M 135 centimeter (L x W) Printed Bed Sheets(BED SHEET ):Technical Specification of the Product-Sheeting, Tickings and Bedsheets (V2) as per IS 175 BIS Certifcation-No,VarietyVariety - 2,Process of colouring Dyed,Matching Pillow cover 109 Providing 25 liter 3 Star Water Heater,25 Ltr 5 Star Water HeaterCapacity litres (Litres),BEE Star Rating (Central Ministries/ Departments while procuring shall ensure that the items carry 5 star or higher Star Rating of BEE)-3,Availability of Type Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification-No,Material of Inner Container Vitreous enamelled inner tank conforming to IS-13273 110 Providing Wall Mount Mesh Filter T-Shapped Kitchen-Chimney Material of Blower Body-Aluminium,Material of Blower Blade Aluminium,Material of Exhaust pipe-pvc,Filter Material,Stainless Steel,ShapeT-Shapped,Filter Type,Mesh Filter,Control Panel Type Soft Touch,Mount Type,Wall Mount 111 Providing Potable Water Purification System With Inbuilt Water Cooler. RO UV Aquaguard(Hot & Cold uv+ ro) Specifications-Flow rate (Litres/hr.)-12,Cold water storage capacity (Litres)-11 liter,Cooling capacity (litres/hr.)-4,Hot water storage capacity (Litres)-1.5 liter,Heating capacity (litres/hr.)-1.5,Cooling power consumption (Watts)-230,Heating power consumption (Watts)-550. 112 Providing300 L 3 Star Frost Free Double Door Refrigerator, of specification Cooling type:Frost free,Exterior body built:steel,Shelf material -Toughened glass,Voltage Range-160-300V,frequency-50 Hz 113 Providing900 mm wide 2000 mm high Metal Shelving Racks,Specifications :Type-OPEN TYPE Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted)-4,Shelves Material-0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,Depth in mm (±5 mm)-400,Width in mm (±5 mm)-900,Height in mm (±5 mm) 2000 114 Providing and fixing Drawers of Specification of Dimension (in cm)-H91 X W90 X D44in Brown Finish,primary material-Engineered wood,Weight 49.45kg 115 Providing and fixingDressing Table With cupboard and open shelves-Design of Dressing table With drawers,cupboard and open shelvesBase of dressing table Rectangular wooden frame Number of side mirror-1 number, Material specification-Prelaminated particle board of grade II type III of IS 12823/Latest.both side laminated. outer side laminated with shade matching with top shade and fascia shade and having balancing laminate of 0.5mm thick on other side Material thickness of complete body, Fascia and drawer/cupboard-19 millimeter,Material thickness for back, partition and drawer /cupboard bottom ± 2mm,19 millimeter 116 Providing and fixing Material & Subtype Solid Wood - Rubber Wood Table Top Material Solid Wood-Frame Material Solid Wood,Finish Glossy,Colour & Colour Family Brown - Walnut Dimension Of Table (W) 600mm X (D) 600 X (H) 610mm Dimension Of Chair (W)640mm X (D)530mm X (H)560mm Size Standard 117 Providing and fixing Wooden Double Bed Storage Box Opening From Material of Mattresses Panel-Other wood, Material of Bottom Panel of Storage Box-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Front, Back and side Panels Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Headrest Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Legrest-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest,Type of Bed-Wooden Double Bed Material of Bed Frame-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest 118 Providing and fixing 1 Seater Sofa With Leatherite Cover Sofa Set is Foldable to use as bed-No Backrest Cushion Material-Foam,density of Cushion of Backrest Material (Kg/Cubic M)-40 Covering Material for Seat and Backrest Fabric Frame Structure Material and size (±1 mm) Any other wood of minimum 25 mm thickness Seat Cushion MaterialFoam 119 Providing and fixing 8 SEATER Rectangular MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823/(Elanor Marble 8 Seater Dining Set) 120 Providing and fixing MODULAR TABLE L X D & H 2000 millimeter X 450 millimeter 700 millimeter (Alice TV Unit marble),Sprcification-Mode of Supply of modular table Knocked Down to be assembled at consignee site by the Seller Storage Provided one side,Number of storage unit-triple storage,Table Top material and thickness ±3mm-25mm thickness three layer pre-laminated Particle boards (Wood Product) of grade II Type II of IS 12823 Latest Gable end and modesty panel material and thickness-18 mm thickness three layers pre-laminated Particle boards (Wood Product) of grade II Type III of IS 12823 Latest 121 Supplying of Library Management Department. and NDL Softwares,Server Machines, Air-Condition Systems,Xerox Machines,Lamination Machines, CONNECTION)Binding Machines,Furniture/Furnishing. Computers, Printers,Computer System(with Internet Connection) 122 Supplying of Printer of Specification A Printing Technology Laser-Cartridge Technology,Composite Cartridge,Type of Printing Mono,Paper Size-A4 Print Speed per minutes per Department Incharge 123 Supplying of XEROX Machine(standard company) Type of MachineMultifunction Machine,Print Technology-Laser Type of Printing-Mono,Cartridge Technology Separate Drum and Toner (Dual Component) Platen/Flatbed Size-A3/A4,Paper Size (Original/Image)A3/A3 RAM size (MB)-4096as per Department incharge 124 Supplying of Determination of wavelength of He-Ne Laser light using Grating(Specification- Output Power: up to 15mW, CW - Wavelength: 632.8nm,* Mode Structure: TEM00 (>95%)* Beam size: <= 1mm* Beam Divergence: <= 1.5 mrad* Polarisation: Unpolarised, Vertical Polarisation. complete set up as per Department incharge 125 Supplying of Brewsters Law using spectrometer(Brewsters angle apparatus differ goniometer digital research bench polarizer analyser with rail type bench abron). complete set up as per Department incharge 126 Supplying of Determination of wavelength of Sodium light using Michelson interferometer(Power-3 kW,Usage-Physics Lab,Material-Mild Steel,Power Source,Electric Voltage 240 V). complete set upas per Department incharge 127 Supplying of Determination of wavelength of Sodium light using FabryPerot interferometer complete set up of Specification Flatness of Reflective Mirrors-λ/20 Diameter of Reflective Mirrors-30 mm Reflectance of Mirrors-95% Effective Travel of Preset Micrometer~ 3 mm Min Division Value of Preset Micrometer-0.01 mm Travel of Fine Adjustment of Movable Mirror-1.25 mm Resolution of Fine Adjustment-0.0005 mm Low-Pressure Sodium Lamp-20 W as per Department incharge 128 Supplying of Resolving Power of Telescope complete set up (specification Color-BlackMaterial-Plastic as per Department incharge) 129 Supplying of Resolving Power of Prism(Resolving power of telescope assists the user to know the basic principle of telescope. Fabricated using excellent quality metals, glass and plastic material, it is widely used instrument in scientific lab of colleges and research centers. It is known for accurate calculation and longer service life) complete set up as per Department incharge 130 Supplying of Production and analysis of Polarised light using half and quarter wave plate(Usage/Application Laboratory Voltage-230 V,Color-Black,Material-SS). Complete set up as per Department incharge 131 Supplying ofLogarithmic Amplifier(Built in power supply : +15V & -15V DC,Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet,Weight : 2KGS APPX) complete set up as per Department incharge as per Department incharge 132 Supplying of Zener diode characteristics & voltage stabilizer. Complete-Specification:(Voltage-240 V Frequency-60 Hz,Display Type -Analog)in all respect as per Department incharge 133 Supplying of FET characteristics complete up(Technical specifications-Inbuilt variable, overload & short circuit protected DC regulated power supplies of 0- 5 volt & 0- 15 volt.Voltmeter & ammeter are mounted on the front panel.One FET.Highly insulated front panel .Trainer helps to demonstrate the working principle of FET.Set of required number of patch cords.Multi - colored sockets are used.Housed in an elegant powder coated metal cabinet.Strongly supported by a comprehensive instruction manual complete with theory and operating details.LED indication for supply “ON” to work on 220V AC Mains.) as per Department incharge 134 Supplying of MOSFET characteristics complete set up(Specificaion:Power-AC Mains,Usage/Application-Laboratory Type-Analog,Material-plastic,Power Supply-ac mains, as per Department incharge 135 Supplying of UJT characteristics complete set up(Specification-Usage/Application-laboratory,Type-Analog,Display Type-Analog meters,Power Supply-ac mains)as per Department incharge 136 Supplying of Transistor biasing (CE mode)(Specificaion-Operating Power Supply-220VAC On Board Power Supply 0-1VDC & 0-10VDC Experiment Input & Output Char In CB & CE Mode OF PNP Tr.Meter Type Analog / Digital)set up as per Department incharge 137 Supplying of Characteristics of SCR(SpecificationUsage/Application-laboratory Type-Analog Automation Grade-Manual ,Power Supply-ac mainscomplete set up as per Department incharge 138 Supplying of Basic Logicgates and Universal gates. Operating Supply Voltage 230V,Logic Family-DIGITAL,Number of Inputs per Gate-2,Usage Laboratory,Material-ELECTRONIC Complete set up in all respect as per Department incharge 139 Supplying of Op-amp Integrator &Differentiator. Complete set up in all respect :Product Specification:Type-Analog Material-Metal,Automation Grade=-Manual,Color-black with multicolour PVC front panel,Power Supply-230,Capacity--5,connector Type-patch cord sas per Department incharge 140 Supplying of Half Adder, Full Adder and 4-bit binary Adder. Complete set up in all respect (Product Specification:Type-Digital,Display Type-Digital Interface--NO Material-ABS,Display-Digital,Pulse Generator-50Hz Variable Dc Output-no)as per Department incharge 141 Supplying of G. M. Counter for 6 digits GM counter with built in power supply complete set up(G.M.COUNTER: COMPLETE WITH INBUILT POWER SUPPLY EHT 250-1200v Workable on 220v. 50Hz., Power consumption 8W approx. STOP, START, RESET switches. Counts Capacity : 6 DIGIT COUNTING SYSTEM, Preset time : 3 DIGIT PROGRAMABLE TIMER WITH DIGITAL DISPLAY. 3 ½ Inbuilt Digital Volt Meter for GM TUBE Voltage. G.M.TUBE: END WINDOW G.M.TUBE MOUNTED IN ACRYLIC STAND. WITH ‘LEAD’ AND ‘ALUMINIMUM’ ABSORBENTS, Radioactive Source: ONE RADIOACTIVE SOURCE BETA or GAMMA (in Lead Container and wooden Box) SOURCE, . Dimensions : 460X370X230mm.(Complete instrument is HOUSED in corrugate box with Export Packaging) Wight : Total weight of the Instrument is 5.5kg.) as per Department incharge 142 Supplying of Measurement of Dielectric constants of solid and liquid samples complete set up(It Consists of following partsRF Generator (9-10MHz Approx) Micro Ammeter (Range 0-50mA) Potentiometer for Sensitvity Selection Fixed Capacity (Metal) Variable Gang Capacitor Socket for test Capacitor & Variable Capacitor brought out at front panel One Solid bakelite plate to be insert in gap of test capacitors)as per Department incharge 143 Supplying of Study of Dielectric constants and Curie temperature of ferroelectric ceramics Complete in all respect(Specifications Temperature Range : Ambient to 200°C,Display : 31/2 digit, 7 segment LED with autopolarity & decimal indicationResolution : 0.1°C,Accuracy : ±0.5°C (typical),Stability : ±0.1°C Power : 150W,(ii) Digital Capacitance MeterThis a compact direct reading Instrument for the measurement of capacitance of the sample. Specifications,Range : 50-6000 pf,Resolution : 1pf Display : 3½ digit, 7 segment LED, Typical results obtained with the above set-up are as shown in the graph) as per Department incharge 144 Supplying of Determining Optical constants of a metal by reflection of light Complete in all respect (Specification-Power-AC Mains,Usage/Application-Laboratory,Type-Digital Material-Metal,Automation Grade Manual,Color-White Power Supply-AC Mains,Display Type-Digital) as per Department incharge 145 Supplying of Lattice dynamics kit with frequency meter (Technical Specifications: Audio Oscillator 100 khz,Built in Power Supply and Output Stage to match the Impedance of Simulated Lattice,Lattice DynamicKit consists of Transmission line, which Simulates One-Dimensional Mono-AtomicandDi-atomicLattices,. LCD Based Frequency Counter is Provided on panel to Measure Frequencycomplete set up as per Department incharge 146 Supplying of BCD to seven segments complete set up(Specification:Built in power supply : +5V DC Mains : 230V AC Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX) as per Department incharge 147 Supplying of Monostable Multivibrator using Oscilloscope (CRO) complete set up (Specification:Usage/Application Laboratory Packaging Type-Corrugated Box,Connector-2mm sockets Frequency Range -50Hz) as per Department incharge 148 Supplying of Bistable multivibrator using Oscilloscope(CRO))Technical Specification:(Built in power supply : +12V & -12V DC Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX)complete set up as per Department incharge 149 Supplying of Pulse code modulation and demodulation complete setup (Product Specification,Type Laboratory Trainer Kit Usage/Application-Laboratory,Accuracy-+/- 10%,Frequency-50 Hz Input Voltage-220V,Packaging Type-Corrugated Box,Power Source-ElectricShape-Rectangular,Material-ABS or Metal Cabinet)as per Department incharge 150 Supplying of Addition, Subtraction, Multiplication using 8086 microprocessor(Product Specification,Usage/Application-LaboratoryType-Fully Automatic,Automation Grade-Semi-AutomaticClock Frequency-Yes,Color-Green,Display-Digital Packaging Type-Corrugated Box, Power-200-400 Weight 2 Kg) as per Department incharge 151 Supplying of Thevenin theorem, (THEVENIN’S AND NORTON’S THEOREM APPARATUS,Technical specifications Inbuilt fixed DC regulated power supply of 12 volt. Voltmeter & ammeter are mounted on the front panel. Resistive network is used in the circuit. Circuit diagram is printed on highly insulated front panel . Trainer helps to demonstrate the working principle & verification of Thevenin’s & Norton’s Theorem based on resistive circuit. Student can calculate & measure the value of current & voltage for different load circuits. Calculation of power consumed by the circuit. Facility for connecting external Power Supply. Set of required number of patch cords. Multi - colored test points are provided in the circuit to observe voltages at different points. Housed in an elegant powder coated metal cabinet. Strongly supported by a comprehensive instruction manual complete with theory and operating details. LED indication for supply “ON” to work on 220V AC Mains. Circuit protection through glass fuse)Complete set up as per Department incharge as per Department incharge 152 Supplying of Active filter set up(Product Specification Operating Temperature-0-50,Frequency (Hz) 50,Condition-New Temperature (deg. Celsius)-50,Usage/Application Industrial, Educational, Residential, Commercial) as per Department incharge 153 Supplying of A to D counter type complete set up (Product Description-M-32 AD M-16 AD,Input AD: 1/4 TRS jack and 25 pin D-sub, servo balanced, completely symmetrical audio path, Output AD: 4 x ADAT optical, 1 x MADI optical/coaxial,Dynamic Range AD: 113 dB RMS unweighted, 116 dBA,THD AD: < -110 dB (< 0.00032 %),THD+N AD: < -104 dB (< 0.00063 %) Crosstalk AD: > 130 dB,Input level for 0 dBFS: +24 dBu, +19 dBu, +13 dBu,Frequency response AD, -0.1 dB: 10 Hz - 23.2 kHz (sf 48 kHz),Frequency response AD, -0.5 dB: < 5 Hz - 45 kHz (sf 96 kHz) Frequency response AD, -1 dB: < 5 Hz - 80 kHz (sf 192 kHz) Sample rates: 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (Sync/WC),Jitter: Typical < 1 ns for internal, Word Clock, ADAT and MADI input Jitter sensitivity: all PLLs operate error-free even at 100 ns,Jitter suppression: > 30 dB (2.4 kHz),Power supply: Internal switching mode PS, 100V - 240V AC, 60 Watt Dimensions: (WxHxD) 483 x 88 x 200 mm)as per Department incharge 154 Supplying of Determination of Plancks constant(1. 1 0-2V D.C. at 20mA Variable Power Supply. 1.2 Digital Panel meter 3½ digits range 2mA. 1.3 Digital Panel meter 3½ digits range 2 volt 02 Lamp House: 100W Bulb with stand 03 Vacuum Type Photo Cell : Mounted in a Iron box. 04 Three different colour optical filters 05 Adequate no. of patch cords stackable 4mm spring loaded plug length 50cm. 06 Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.) as per Department incharge 155 Supplying of Determination of Energy Band Gap using Four Probe method(Product Specification:Type-Energy Band Gap Usage/Application-Laboratory,Connector-4mm Banana Socket Frequency-50Hz) as per Department incharge 156 Supplying of Determination of Hall coefficient and Hall angle in Hall-effect(Product Specification,Display Type-0-20V DC, 0-5 A, digit LED, Primary safety socket,4mm Electro Magnet Coils 500 T, Voltage resolution -0.1V,Current Resolution 0.1 A) as per Department incharge 157 Supplying of Determination of magnetic susceptibility using Guoys method(Usage/Application Physics Laboratory Type Of Instruments-Magnetic Susceptibility Gouys Balance Method Experiment Setup,Power-230V , 50Hz, +-10% Display Type-LED Type) as per Department incharge 158 Supplying of Study of absorption pattern of a given sample using FTIR spectrometer(Product Specification,Detector-High performance pyroelectric infrared detector,Weight-15 kg Software-1,Voltage-100-240V AC,Electronic System-24bit A/D converter at 500KHz, USB 2.0,Wavenumber Range-7800~350 cm-1Power-100-240V AC,50/60Hz,Signal Noise Ratio-30000:1 (resolution@4cm-1 , sample and background scan for 1 min@2100cm-1 ),Light source-Long life, steady state infrared emitter Beam splitter-coated KBr,Resolution-1 cm-1,Dimension-430mm x 360 x200) as per Department incharge 159 Supplying of LCD Projector and smart board (Product Specification,Projection Distance-<1 m Resolution-WXGA,Lamp Life-5000/9000/10000 HOURS Screen Size-100,Display Type-LCD,Dimensions-400X367X149MM Connectivity Type-Dual HDMI, HDMI,Brightness-2000-4000 Lumens Color-White) as per Department incharge 160 Supplying of Desktop(ntel Core I3/ 10th Gen/ 4GB RAM/ 1TB HDD/ DOS/ NO DVD/ 19.5 Inch Monitor/ 1 Year Warranty) as per Department incharge 161 Supplying of Printer(Product Specification,Printer Type-Ink Tank Color Output-Color,Print Speed-22 ppm,Paper Size-A4,Dimension-403 x 369 x 150 mm,Weight -6,Warranty-One Year or 50,000 pages which ever is earlier) as per Department incharge 162 Supplying of Printer (Product Specification Printer Type-Inkjet Color Output-Color | B&W,Print Speed-10,Paper Size-A4,Connectivity-USB,Dimension-377 x348 x179,Weight-3.9 Print Volume-any)as per Department incharge 163 Supplying of XEROX Machine (Product Specification,Functions-Photocopy,Supported Paper Size-A3,Supported OS-Windows 10 Color Output-Black & White,Number Of Trays-1,Item Color-Black & WhitePrint Speed-22 PPM,Weight-40 kg,Print Technology-Laser Input Tray Capacity-350 sheets,Warm-Up Time-5.6 Sec,Duty Cycle-80000 / Month,Resolution-600 x 600 dpi Connectivity-Ethernet & USB,Duplexing-Yes)as per Department incharge 164 Supplying of computer system with internet connection,PC Specifications to be followed :Processor Intel Core i5(10th Gereneration or newer ),RAM-8 GB or Higher HDD:512 GB,SSD,Monitor 24 LCD Monitor .OS:Windows 10 Professional ,Anti virus:User Licence for one year as per Department incharge 165 Supplying of Laptop (with Internet connection),Processor intel Core i5(11th Generation or newer),RAM 8 GB or higher HDD:512 GB,SSD Monitor 14 screen ,OS Windows 10 Professional ,Antivirus :User Licence for one year 166 Supplying of LCD Projector (Specification-Brightness:2000-4000 Lumens,Resolution-FULL HD 1080P,Connectivity Type-Dual HDMI, HDMI Display Type-DLP,Power Supply-100-240V Portable-Yes) as per Department incharge 167 Supplying of Smart Board (Frame Material-Aluminium Usage/Application-School, Education, etc,Effective Touch Area-72 x 48 inch Material-Ceramic Input Method-USB Power Consumption-150 - 220 W,Shape-Rectangular) as per Department incharge 168 Supplying of MS Suite Software(Specification-Microsoft Office Software,Operating System:For Windows,Brand:Microsoft )as per Department incharge 169 Supplying of Adobe Photoshop Software(Specification -Graphic Design and Photo editing,Licence-1 yea) as per Department incharge 170 Supplying of windows10 OS Software(Specification-License Duration-Life Time,Architecture-32/64 Bits,Operating System For WindowsAlso Provides,Windows Operating System,Provide Installation Service-Yes Support 24/7 (Live Rep)) as per Department incharge 171 Supplying of Laptop of 11th Generation intel core i3,1115G4 processor (6 MB Cache up to 4.1GHZ)windows 10 Home Single language English,intel UHD Graphics with shared graphics memory 8GB ,8 GBX1,DDR4,3200 MHZ,512 MB,2 PCLeNVMe Solid state drive pebble (Top colour is pebble colour,Base and palmrest are black colour as per department incharge 172 Supplying of Desktop of 10th Generation intel core i5-10500T (6 CORE,12MB Cache 2.3GHZ to 3.8GHz,35W ),Windows 10 Pro (64 Bit )English,intel integrated graphics),8GB ,1X8 GB,DDR4 non-EC0C Memory,2.5 inch TB 7200 RPM ,SATA Hatd disk drive 5480AJO 23.8 FHD 1920X10080 ips non touch,Antiglare camera,integrated graphics,Bronze 1505w PSU as per department incharge 173 Supplying of Printer (Specification:Item Weight-12 Kg,Package Dimensions-60 x 56.5 x 38 cm,Connectivity Type-Wi-Fi Operating System-Windows)as per department incharge 174 Supplying of Fumehood(Specification:Type-exhaust,LED-Tube fitting,Power-230 volt,Working Top-Granite ,MOC-GI with PU coated Storage includedas per department incharge 175 Supplying of electronic balance(Specification -Usage/Application-Laboratory,Accuracy-0.01%,Calibration-Fully Automatic,Type Of Weighing Scale-Digital,Voltage-110-220 V Mounting Type Desktop) as per department incharge 176 Supplying of Magnetic stirrer Magnetic stirrer Hot plate (Specification-Weight-2.3 kg,Timer -999 minutes,Temp. Accuracy-+-1 Deg.C(<100 Deg.C)+-3 Deg.C(<300 Deg.C),Dimensions LxWxH (mm)-230 x 180 x 120,Max.Temp. (Plate Surface) 300 Deg.C,Power supply-AC 220V / 50 Hz,Top Plate Size 135 x 135 mm,Display-LCD,Max. Volume (ml) 2000 ml,Speed (RPM)-1250 RPM Plate Material Steel per department incharge 177 Supplying of HOT Air oven of made inner material-stainless steel,Outer material -mild steel ,Surface treatement -Powered coated ,Sizes-Different sizes,Gravity conviction type-Double wall.Mechnical conviction -Triple wall as per department incharge 178 Supplying of colourimetry , Ery colour colorimeter industrial and research purpose stability( Product Specification:Material-Aluminium Alloy,Automation Type Automatic,Brand -DD-LAB ,Dimension-210 x 160 x 80 mm,Display Type-Dual Digital DisplayLight Source-Highly Accurate Laser Source,Stability- + 0.02 O.D. Per Hour Volume 1 ml. minimum,Filters layer-Built in 9 Digital filters 30,000 hours Life,Weight-1.5 Kg,Battery Backup-6 V Ni CD Re-chargeable Battery,Detector Silicon Photo-diode,Display Model Absorbance & Wavelength,Filter Wavelength 680 NM Country of Origin Made in India) as per department incharge 179 Supplying UV-Vis Spectrophotometer Fully touch screen portable UV Spectrophotometer shimadzu model name:UV 1900,Brand :shimadzu,Display =fully touch screen,Type-portable,size 450x501x244 as per department incharge 180 Supplying of potentiometer ,Range-0 to 1999.9mv,Resolution-1 mv,Repeatability -1mV,Accuracy +1 mv+ digit,Input impedency-10ohms,operating temperature 10 to 50 degree Celsius,Display 1/2 digit 0.5 seven segment LED Display indication,Power-230V+10,50hZ,Dimensions 76x275x170 mm,weihjt 2 kh as per department incharge 181 Supplying of Conductivity meter,LT 26 Deluxe conductivity meter,Product details:Model no-LT-26,Brand -Labtronics,Usage-Laborataty,Display type 3.5 Digit LEDas per department incharge 182 Supplying of Online COD/BOD Detector analyzer warer quality monitoring probe,Measure range-0-200/0-1000mg/l,Resolution -1 mg/l ,Accuracy +5%F.s ,Under pressure-1 bar,Power supply -12-24V DC ,Temperature range 0-45 degree ,Production leve;-IP68 as per department incharge 183 Supplying of melting point appratus,Temperature renge -2 degree above ,Readability 1 degree ,Display -3 Digit LED,Heating rate control-Electronic,Temperatre sensor PT-100as per department incharge 184 Supplying of Ph meter Labrtonics,Range:0-14pH,Resolution:0.01pH,Accuracy:0.01pH(Relative),Temp comp:Automatic wvith temp probe,Buffer:Manuals with keys as per department incharge 185 Supplying of Spectrum 3 FT-IR Spectrometer,Model no.-LI280127,Wave length -11000-30 cm-1 as per department incharge 186 Supplying of Stopwatch NIVIA 600 plastic(Product Specification:Color-Black,Usage/Application-Sports,Time Display 12/24 hour display for user option,Material-Plastic,Dial Shape-OvalMaximum Counting-23 hours 59 minutes 59 secondsas per department incharge 187 Supplying of Digital Bomb Calometer(Specification-Auto Off Automatic,Frequency-50 Hz,Voltage-230-280 V,Operating Time Per Test 10 minutes,Power Source Electric(Automatic) as per department incharge 188 Supplying of Microprocessor viscometer ,Product details: Measuring range-101x105mpa,,Spindles-4 Spildles,Rotor speed(rpm)-6/12/30/60 rotor speed rpm as per department incharge 189 Supplying of Flame photometer,Product details:Application-Laboratory use,industialuse,,weight 705kg ,Curve fit accuracy,Resolution-0.1ppm/meq as per department incharge 190 Supplying ofwater purification system,Resolution-18.2 M ohm cm at 25 degree C,Weight-19.5kg,Frequency-50-60Hz as per department incharge 191 Supplying of Refrigerator of 7.5kg fully Automatic Top Load washing machine (Hard water wash,Grey,5 star,10 years warranty as per department incharge 192 Supplying of water bath ,unstirred water bath s ,Digital info Water bathdigital,18L amb+5 tp 99 degree C includes clear lid and base trayas per department incharge 193 Supplying ofmini rotary shakers 50to 400RPM,features-220/230 V ac,Power supply-50-60Hzas per department incharge 194 Supplying of Magnetic stirrer- capacity 5 litre Spinit Digital Magnetic Stirrer Features-Type of Product-Magnetic stirreras per department incharge 195 Supplying of Digital ultrasonic cleaners (Specification: tank capacity 4 L, ultrasonic power 100W, Heating, Power-100W, time setting 1-99 min, heating temp up to 80 degree, in and out both in ss, with digital timer auto stop of sonication. 230V AC +-10% 50HZ. Tank size 300x150x100mm, overall size 330x180x240mm.supplied with basket and Lid.) as per department incharge 196 Supplying of Calomel electrode (Product Specification:Packaging Type-Box.,Length-120 mmUsage-Electrochemical Study(Laboratory))as per department incharge 197 Supplying of Pt-wire counter electrode (Product Specification Electrode Diameter-0.5 mm,Power Source-10A) as per department incharge 198 Supplying of UV-LAMP Cabinet(Product SpecificationSize/Dimension-15 X 12 X 10 (H) Light Source-3 NOS , SHORT WAVE -254nm-1no, LONG WAVE-365nm, VISIBLE LIGHT,Material-MILD STEEL,Voltage 230 V AC) as per department incharge 199 Supplying of Magnet (Magnet Grade-N48 Shape-Cup & Pot,Material Neodymium,Dimensional Tolerance+-0.05 mm,Plating / Coating-Ni-Cu-Ni Colour-red,Surface Gauss 3000 Gauss,Maximum Working Temperature (Deg. C)-230 Deg. C as per department incharge 200 Supplying of Micro Centrifuge tube(Specification: Usage/ApplicationLaboratory Analyzers,Material,Polypropylene Color-White,Pack Contains--20 Packet / carton & 500 pcs / packet,Shape-Conical,Length-4.1 cm,Inlet Diameter-1.3 cm Capacity2 ml)as per department incharge 201 Supplying of Micropiprtte(10-100uL),(Product Specification Capacity-10 ml,Volume Increment -0.1 microlitre Material-Glass,Autoclavable-Yes)as per department incharge 202 Supplying of Micropiprtte(10-1000uL),( Product Specification Material-Plastic,Capacity-Up to 1000ul,Color-Transparent Usage/application-Chemical Laboratory) as per department incharge 203 Supplying of printer-Black and white print ,scan,copy all in one printer Product Specification Print Speed-Up to 18ppm / 19ppmLaser Printer,Color Output-Black & White,Print Technology LaserjetUsage/Application-Printing,Supported Paper Size-A4 Compatible Operating Systems1,Windows 8,Windows 7,Windows Vista,Windows XP,Windows 2000,Mac OS X 10.4 - 10.8,Linux*3 Print Resolution-Up to 600 x 600DPI,1 200 (Equivalent) x 600DPI,Print Language-UFR II LT Dimension-372 x 371 x 254mm (With the Cassette Opened)Weight(W/O CRG)-7.6kg,Monthly Duty Cycle-8000 Pages Power Consumption 960W(Maximum),First Printout Time7.8s / 7.7s (A4 / LTR),Zoom 50 - 200% in 10% Increments Refill Type Toner Cartridge,Internal Memory 64 MB Printer Language UFR II LT (Host Based),Paper Weight 60 to 163g/m2 (Cassette),Copy Speed Up to 18 / 19Cpm (A4 / LTR) Halftones 256 levels,Copy Resolution 600 x 400 DPI Display 7 - Segment,1 - Digit LED as per department incharge 204 Supplying of printer-colour print ,scan,copy all in one printer (Specification :Functions-Print | Scan | Copy,Technology-Inkjet Color output-Color | B&W,Connectivity-Wireless(Wi-Fi) Usage-For Office ,Paper size-A4,Print speed upto 40 pages/min)as per department incharge 205 Supplying of photocopier branded fast print 50ppm high image resolution superior print quality,fast scan up to 50ppm A4 Monocolouras per department incharge 206 Supplying of LAN.Networking,cabling,switches,Wi-Fi points(10 points in each department) as per department incharge 207 Supplying of installation of Printer (Black and white),Printer( colour),Photocopier and LAN,Networking,Cabling,Switches,Wifi Points as per department incharge 208 Supplying of RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio as per department incharge 209 Supplying of Freightof RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio) as per department incharge 210 Supplying of wall mount (Dimension long:Telescopic Adjustable CCTV camera mounting bracket -Color: Beige Universal Camera Bracket, Heavyduty weatherproof iron bracket fits mostbrands of outdoor camera housing,Iron stand Platsic APPLICATION: Ideal for indoor outdoor dome cameras, Security Camera Mount Bracket, high quality with professional design,more stable and reliable.Hidden hole: Cable can feed thru L bracket tothe housing thus provide cable protection Outdoor and Indoor Use.)as per department incharge 211 Supplying of Camcorder Compact full HD ENG Camera with 20X zoom and 5 axis image stabilization. 20X optical zoom (26.8mm, F/1.8-576MM, F/2.;28.8MM, f/1.-576mm). 5 axis image stabilization. Support formats: full HD50P/60P, AVCHD/MP4;SD card slots 2 35mm film camera equivalent when dynamic IS is turned on with Tripod as per Department Incharge 212 Supplying of Video capture and video capture card (Product Specification:Converter type-USB,Material:Metal,Audio Jack:3.5 mm,HDMI Version:Hdmi-1.4,Audio:44100 AU,Video:Full HD Frame:48000 Resolutions)as per department incharge 213 Supplying of UPS(1KVa)(Product Specification: Type-Online UPS,Capacity-1 kVA,Configuration-1 Phase IN - 1 Phase OUT,Protection-OverVoltage,Form Factor-Tower Model Back Up Time-20- 30 Mins,Frequency-40 ~ 70 Hz (auto-sense) Usage/Application All) as per department incharge 214 Supplying of Studio light-125watt,5 LED BULBS consisting of 25watt bulb(Colour Temperature:5500 kelvin)as per department incharge 215 Supplying of Live streaming software for live streaming or live telecast as per department incharge 216 Supplying of Cables,installation,SSD Card(SAMSUNG VNAND SSD 850 EVO 2.5 250GB SATA III 3-D Vertical Internal Solid State Drive (SSD) MZ-75E250B/AM) as per department incharge 217 Supplying of complete making soundproof class(20*20 feet Room) as per department incharge 218 Supplying of RFID Tags RFID Book Lables(specification: Language ‏ : ‎ English,Simultaneous device usage ‏ : ‎ Unlimited Text-to-Speech ‏ : ‎ Enabled,Screen Reader ‏ : ‎ Supported Enhanced typesetting ‏ : ‎ Enabled,X-Ray ‏ : ‎ Not Enabled,Word Wise ‏ : ‎ Not Enabled) as per department incharge 219 Supplying of Anti theft stickers with the university logo(Polycarbonate 175 Microns Matt Finish) as per department incharge 220 Supplying of Middleware Application Desktop(writing and read tags) as per department incharge 221 Supplying of RFID Staff station or desktop reader (used for Tagging of books and circulation) operations through RFID as per department incharge 222 Supplying of Integration with software and Training of complete RFID System as per department incharge 223 Supplying of Data Encoding,Booking Tagging and Registration per book as per department incharge 224 Supplying of RFID Secuity Gates (2 pedestals - 1 gate),RFID Secuity Gate(Provide Installation Service-Yes,Support-24/7 (Live Reporting Language Support-English) as per department incharge 225 Supplying of Automated book drop box (ntegrated RFID Reader • Approx. 250 Books Receiving Cart (Movable) • Client Software for Checking-in Facility and communicating with LMS with provision for E-mail/SMS confirmation • Has automatic hutch which should open only on valid RFID tags and close once the book has been accepted to prevent the patrons from removing checked in books. • Communication with any LMS Software through SIP2/NCIP protocols • Compliant with internationally recognized standards for RFID based library self-services systems. • Book Drop can display item ID once item is returned. • Enabled with necessary items i.e.: Branded CPU etc. • 15” or higher LCD/LED Touch Screen Monitor. • Ethernet High Speed Receipt Printer (Reputed/Branded) • Customizable Design matching the library aesthetics; Contemporary and attractive. • Design is such that there is not damage to the dropped books. • Library Ethernet network and wireless network compliant. • Optional Features: Fingerprint Scanner, Smart Card Readers etc) as per department incharge 226 Supplying of 5KVA Invertor -online UPS with battery back up 100Mah battery (8 units)(Product Specification,Capacity-1100 Voltage-130V ,Rated Input Power-5 KVA,Display-Digital Type-Square Wave Inverter Country of Origin) as per department incharge 227 Supplying of LAN,Switches,Necessary cabling,casing,power supply port including cables as per department incharge 228 Supplying of Installation charges of RFID Tags,Anti-theft sticker,Middleware Application Desktop,RFID Staff statio,Integration of software,Data incoding books,RFID Secuirty Gates,Automated Book Drop Box,Cabling,Casing,Wiring,Switches,LAN as per department incharge 229 Supplying of Air conditioning 1.8Ton heavy duty AC (minimum 3 star rating,Coil material -copper,Power consumption-1950W,Power Requirement -AC 130-285V, 50Hz) as per department incharge 230 Supplying of Desktop,i5 processor ,7th Generation,500GB HDD,4GB RAM,23.8 INCH LED Backlit Monitor,Full HD IPS Panel(Brand-HP,Dell,Acer) as per department incharge 231 Supplying of Headphone with built in microphone,(Communication-Wired) as per department incharge 232 Supplying of 75 diagonal length with 3 GB RAM and 48 GB ROM ,Slim frame anti glare glass.3M Antiglare ,H7 Touch surface hardness,Light weight for easy installation as per department incharge 233 Supplying of Dedicated server-HPE Proliant DL 380,Gen 10 5218.2.3GHz 16core ,1P-32GB-R P408ianNC 8SFF 800WPS Server,Intel xeon G5218 Kit for DL 380,Gen 10 as per department incharge 234 Supplying of 5.5KVA Inverter with battery backup,Microtek inverter,online UPS ,65Mah battery(16 unit )-Exide as per department incharge 235 Supplying of Freight Transportation Charges of Desktop,Headphone,LAN Switches,4K-OPS,Dedicated server,5.5 KVA Inverter with battery back up and Air conditioner as per department incharge 236 Supplying of 86 Diagonal interactive display,3 GB RAM,48 GB ROM,4K Display Android model,Slim framenAnti glare Glass,H7 Touch Surface hardness ,Light weight for easy installation ,Media Suits for Annotation softwatr bundled with education Apps as per department incharge 237 Supplying of 4k OPS i5,7th Gen,8GB RAM,128 GB SSD as per department incharge 238 Supplying of play mounting including white board & Green board,Material post formed ply,Size 15ft(length)x7ft(ht) with green board for chalk,whiteboard for marker and cupboard as per department incharge 239 Supplying of UPS (1KVa,Phase-Single phase.Back up Time 10-20 min,Frequency-50Hz) as per department incharge 240 Supplying ofTraining and installation of 86 diagonal interactive display,4k-OPS,Play mounting including white board & Green board and UPS of 1KVA as per department incharge 241 Supplying of Digital Podium PTGN 500 Windows 8.1 LCD ,Electronic Lectern,On site OEM Warranty in 3 yearsas per department incharge 242 Supplying of PA System sound system with amplifier 350 watt ,30 watt speaker (4 nos) as per department incharge 243 Supplying of wireless mic Dual channel cordless microphone as per department incharge 244 Supplying ofTraining and installation of Digital Podium,86 Diagonal interactive display (4k display),4K-OPS,Play mounting including white board and green board,5KVA invertor,PA System and wireless mic as per department incharge 245 Supplying of Desktop :- 1).i5 Processor, 7th Generation, 500GB HDD, 4GB RAM, 2).23.8 inch. LED backlit Monitor Full HD IPS Panelas per Department Incharge 246 Supplying of 55 LED Display for CCTV Branded LED Display as per department incharge 247 Supplying of CCTV Camera IP based CCTV camera,2 TB Space with NVR with necessary accessories as per department incharge 248 Supplying of Stagmometer as per Department Incharge 249 Supplying ofViscometer as per Department Incharge 250 Supplying of Beaker-50ml as per Department Incharge 251 Supplying of Beaker-100ml as per Department Incharge 252 Supplying of Beaker-250ml as per Department Incharge 253 Supplying of Beaker-500ml as per Department Incharge 254 Supplying of Beaker-1000ml as per Department Incharge 255 Supplying of Buchner Funnel 3 as per Department Incharge 256 Supplying of Buchner Funnel 6as per Department Incharge 257 Supplying of Burette-50ml as per Department Incharge 258 Supplying of Chromatography column 1x18 with stop cock as per Department Incharge 259 Supplying of Conical flask-100ml as per Department Incharge 260 Supplying of Conical flask-250ml as per Department Incharge 261 Supplying of Conical flask-500ml as per Department Incharge 262 Supplying of Conical flask-1000ml as per Department Incharge 263 Supplying of Flat Bottomflask-500ml(Round) B-24 socket as per Department Incharge 264 Supplying of Round bottom flask-50ml Joint B-24 as per Department Incharge 265 Supplying of Round bottom flask-100ml Joint B-24 as per Department Incharge 266 Supplying of 3 neck RB flask B-29,B-19.as per Department Incharge 267 Supplying of Condenser Spiral B-24 and, B-19 as per Department Incharge 268 Supplying of Condenser Spiral B-24 and, B-24 as per Department Incharge 269 Supplying of T-type tube as per Department Incharge 270 Supplying of Rubber Cock No. 10 as per Department Incharge 271 Supplying of Specific Gravity hydrometer 800-1000 as per Department Incharge 272 Supplying of Specific Gravity hydrometer 100-1200 as per Department Incharge 273 Supplying of Universal hydrometer 1000-2000 as per Department Incharge 274 Supplying of Measuring Cylinder-10ml as per Department Incharge 275 Supplying of Measuring Cylinder-50ml as per Department Incharge 276 Supplying of Measuring Cylinder-100ml as per Department Incharge 277 Supplying of Measuring Cylinder-500ml as per Department Incharge 278 Supplying of Measuring Cylinder-1000ml as per Department Incharge 279 Supplying of Measuring Cylinder-2000ml as per Department Incharge 280 Supplying of Measuring flask-100ml as per Department Incharge 281 Supplying of Measuring flask-500ml as per Department Incharge 282 Supplying of Measuring flask-1000ml as per Department Incharge 283 Supplying of Pipette-0.5ml as per Department Incharge 284 Supplying of Pipette-2ml as per Department Incharge 285 Supplying of Pipette-5ml as per Department Incharge 286 Supplying of Pipette-10ml as per Department Incharge 287 Supplying of Pipette-25ml as per Department Incharge 288 Supplying of Separating Funnel-250ml B-24/B-24 as per Department Incharge 289 Supplying of Spatula Flat Spoon 6as per Department Incharge 290 Supplying of Spatula Flat Spoon 5as per Department Incharge 291 Supplying of Stop Cork 2wayas per Department Incharge 292 Supplying of Silica crucible-15ml without Lid as per Department Incharge 293 Supplying of Silica crucible-25ml without Lid as per Department Incharge 294 Supplying of Stalagmometer Straight Graduated as per Department Incharge 295 Supplying of Chemical thermometer 10c-110c as per Department Incharge 296 Supplying of Chemical thermometer 0c-250c as per Department Incharge 297 Supplying of Tiration flask-100ml as per Department Incharge 298 Supplying of Tiration flask-250ml as per Department Incharge 299 Supplying of Tongs crucible S.S.8 as per Department Incharge 300 Supplying of Test tube holder as per Department Incharge 301 Supplying of Filter Flask-500ml as per Department Incharge 302 Supplying of Filter Flask-1000ml as per Department Incharge 303 Supplying of Watch glass 3 as per Department Incharge 304 Supplying of Watch glass 4 as per Department Incharge 305 Supplying of Watch glass 6 as per Department Incharge 306 Supplying of Wire gauge150x150mm as per Department Incharge 307 Supplying of Tripod stand 8 as per Department Incharge 308 Supplying of boiling Test tube 1x8as per Department Incharge 309 Supplying of boiling Test tube 2x8as per Department Incharge 310 Supplying of Reagent Stickers 2x1 as per Department Incharge 311 Supplying of Ordinary Filter paper as per Department Incharge 312 Supplying of Reagent bottles-250mlas per Department Incharge 313 Supplying of Rubber cork as per Department Incharge 314 Supplying of Rubber tube 6mm as per Department Incharge 315 Supplying of Solid Reagent bottle-125mlas per Department Incharge 316 Supplying of Stopwatch plastic body as per Department Incharge 317 Supplying of Test tube stand 12 holes as per Department Incharge 318 Supplying of Thermometer 360 as per Department Incharge 319 Supplying of Test Tube 6mmx15cmas per Department Incharge 320 Supplying of Test Tube 10mmx10cm as per Department Incharge 321 Supplying of China dish 3 as per Department Incharge 322 Supplying of China dish 4 as per Department Incharge 323 Supplying of Brushes for Test Tube as per Department Incharge 324 Supplying of Brushes for Burette as per Department Incharge 325 Supplying of Brushes for Conical flask as per Department Incharge 326 Supplying of LPG gas burner as per Department Incharge 327 Supplying of Condenser Coil 12 as per Department Incharge 328 Supplying of Receiving adopter with vacuum outlet as per Department Incharge 329 Supplying of Plastic Wash bottle-500mlas per Department Incharge 330 Supplying of Pastel and Mortar 3 as per Department Incharge 331 Supplying of Pastel and Mortar 4 as per Department Incharge 332 Supplying of Pastel and Mortar 6 as per Department Incharge 333 Supplying of China Clay 2 as per Department Incharge 334 Supplying of China Clay 3 as per Department Incharge 335 Supplying of China Clay 4 as per Department Incharge 336 Supplying of Petri Dish 3(Borosil) as per Department Incharge 337 Supplying of Petri Dish 4(Borosil) as per Department Incharge 338 Supplying of Distillation Set-Complete flask-500ml as per Department Incharge 339 Supplying of Distillation Set-Complete flask-1000ml as per Department Incharge 340 Supplying of Thermometer Pocket B-14 as per Department Incharge 341 Supplying of Sintered Glass Funnel-25ml as per Department Incharge 342 Supplying of Air Condenser 12 as per Department Incharge 343 Supplying of Burette Stand with Clamp as per Department Incharge 344 Supplying of Cork borer as per Department Incharge 345 Supplying of Capillary Tube for melting point as per Department Incharge 346 Supplying of Dessicators 6 as per Department Incharge 347 Supplying of Dessicators 8 as per Department Incharge 348 Supplying of Dropper with Rubber teats 6 as per Department Incharge 349 Supplying of Dropper 4(Borosilicate glass) as per Department Incharge 350 Supplying of Dropping bottle-125ml as per Department Incharge 351 Supplying of Funnel Stand as per Department Incharge 352 Supplying of Fusion Tubeas per Department Incharge 353 Supplying of Glass Rod as per Department Incharge 354 Supplying of Glass Tube as per Department Incharge 355 Supplying of Stopwatch Steel body as per Department Incharge 356 Supplying of Magnetic Stirrer as per Department Incharge 357 Supplying of Rubber Gloves as per Department Incharge 358 Supplying of Reagent as per Department Incharge 359 Supplying of Sandbath as per Department Incharge 360 Supplying of Tissue Paper(Local made) as per Department Incharge 361 Supplying of Double Beam PC Microprocessor UV-VIS Spectrophotomet erMake:Systroni cs Model: 2202 PC Based Double Beam Automatic source optimization ,Base line calibration & Cell optimization 200 - 1100 nm Range2. 0 nm Bandwidth%T. Abs. Conc . (K factor. Multi standard ). Multi component measuring modesSingle Wave length, Multi Wave length Scan (with multi scan facility). Time Scan. Kinetic scan operating modes Automatic 5 position sample changer Single Position 50 /100 mm Cuvette Holder (Optional) as per Department incharge 362 Supplying of Refrigerated Centrifuge,(Specification:Speed:- 20000 Max.,RCF:- 37570 Max.,Lowest Temp:- -8,Noise:- <-60db)as per Department incharge 363 Supplying of Refrigerated Centrifuge Essential accessories Required:. With angle Heads (with polypropylene tubes)Model- R-248M 24xl.5 ml as per Department incharge 364 Supplying of Refrigerated Centrifuge 2. Voltage stabilizer:- 03 KW Servo controlled Voltage Stabilizer, input 170 volts to 260 volts, output 220 volts to 240volts as per Department incharge 365 Supplying of PCR machine(Specification- Well block, Gradient, temp. range 4° - 99-irC, memory capacity 10000 protocols , display 7inch,volume capacity I 0- 100 μL , preloaded protocol, temperature accuracy ±0.2°C@99°C, with PCR wizard as per Department incharge 366 Supplying of SOS PAGE unit and Western Blot apparatus along with power bank -Mini-TBC electroph_oretic transfer cell, includes: Mini 01P-4 cell tank and lid with cables, buffer, Mini transfer module, gel holder cassettes, 4 fiber pads, cooling units, instructions, Western blot unit, compatible power bank as per Department incharge 367 Supplying of pH Meter With electrode(Type of PH Mater - Portable,Ph Range:0-14,Resolution-0.01pH,compensation-0 to 80 degree celsius) as per Department incharge 368 Supplying of Deep fridge(It is used to store chemicals and preserve samples at very low sub-zero temperatures or below)as per Department incharge 369 Supplying of Autoclave (Vertical)Size- 400 x 600mm ,;Capacity- 75Ltr as per Department incharge 370 Supplying of Hot air oven (Sterilization) as per Department incharge 371 Supplying of Incubator Shaker-Growth and enumeration of microbes (Broth cultures) as per Department incharge 372 Supplying of Horizontal Laminar air flow(Sterile environment Size 4X2)as per Department incharge 373 Supplying of Horizontal Agarose gel electrophoresis unit with gel caster and Power pack Separation of macromoleculeas per Department incharge 374 Supplying of Vortex mixture-To mix content of test tubes and microfuge tubes. as per Department incharge 375 Supplying of Ultrapure Water Purification System:MiliQ Water For distill wateras per Department incharge 376 Supplying of Micropipets - 0.1μL-2.5μL 0.5μL-10.0μL 10.0μL-l00μL 20.0μL-200μL l00μL-l000μL as per Department incharge 377 Supplying of Quebec Colony Counter -Count the microbial colonies as per Department incharge 378 Supplying of Light Microscope (General) 10X,20x, 45x, l00x Visualize microorganisms as per Department incharge 379 Supplying of Bifocal microscope with illuminators, Camera attachment and computer Visualize microorganisms and microgrphy as per Department incharge 380 Supplying of Magnetic stirwith Hotplate and magnetic beads To stir the liquids , preparation of solution as per Department incharge 381 Supplying of Heating mantle For heating round bottomed flask/distillation flask as per Department incharge 382 Supplying of Microwave oven To heat liquids instead of flaming. Samsung/ LG 20 Ltrs as per Department incharge 383 Supplying of Glass Dessicators Used for dessication as per Department incharge 384 Supplying of Fluorescence microscope A fluorescence microscope is an optical Microscope that uses fluorescence and phosphore scence instead of,or in addition to, reflection and absorption to study properties of organic or inorganic substances as per Department incharge 385 Supplying of Electronic Analytical Balance It is used to weigh small quantities of chemicals and samples precisely and quickly. Readability- 1 mg (0.001 g) Cap.- 420gm as per Department incharge 386 Supplying of Electronic Top pan Balance- Readability- 0.1 g Cap.- 2 kg.as per Department incharge 387 Supplying of Double Distillation Unit ,.Approx output: 2 Lit/hrs Wattage:3.3 .KW With safety Cutoff Device Water Stills are carefully designed to produce high purity pyrogen free distiiied water. The water still comprises ofborosilicates glass horizontal typeboiler, coil condenser, constant level device, silica sheathed heaters, along with stand and clamps. All parts are replaceable. pH/conductivity:6-7 / 1-2 μSiem forsingle, 6-7/0.8-lμS/cm for double distilled water as per department incharge 388 Supplying of Microtome-5286(Product Specification Minimum Setting Value-0.5 um,Object Feed-28 mm,Vertical Stroke-60 mm,Specimen Orientation X and Y Axis Universal 8 Degree Trimming Thickness Range-1 um-100 um Operation-Automatic. (Motorized Feed & sectioning and Emergency Stop Provided),Sectioning Speed-0-400 mm/sec.,Specimen-Orientation Z Axis-Upto 360 Degree,Retraction Value-Adjustable Max Specimen Size-50 x 50 mm,Section Thickness Range-0.5 um-60 um)Senior rotary microtome as per Department incharge 389 Supplying of Cryostat -(Product Specification Section Thickness Range-0.5 Micron to 100 Micron (with the increment of 0.5 Micron, 1 Micron, 2 Micron, 5 Micron) Power Supply-220v,Dimension-750mm x 750mm x 950mm (approx) Weight -123 kg (approx),Remote Control-Optional,Sectioning Mode-Single step mode/ Continuous mode Hand Wheel Control-Feather Touch Keypad/ Foot Switch/ Remote Control (optional),Sterilization-U.V-C Sterilization,Cooling down time Up to -30 DegreeC-2 Hour 30 Min Specimen Retraction setting Range-5 Micron to 100 Micron (with increment of 5 Micron),Compressor-Dual Compressor,Cryo Chamber Temp. Adjustable -1 DegreeC to -30 DegreeC Block Holder Head Temperature-Adjustable -1 DegreeC to -35 DegreeC Illumination-LED Lamp)Ultimate usico fully automatic cryostat as per Department incharge 390 Supplying of ELISA -Vet scientific(Specification-Product Specification Automation-Semi Automatic,Assays Performed-ELISAs, Immuno Assays Plate Format-96 well,Optical System Filter-based Detection Method-Absorbance,Number Of User Programs 42 Storage-100000 Results,Filter Positions-8 Display Type-Touch Screen Packaging Type-EXPORT QUALITY,Testing Speed-3 second Type Of Filter 405,450,492, 630,Power Source-115/230 V AC, 50Hz,Weight-9 Kg,Is It Portable-Non Portable, sample Type-Serum, Plasma, Urine, CSF, Whole Blood,sample Volume Range-10-100 Interface-RS232/ USB) as per Department incharge 391 Supplying of Calorimeter -A VI Digital (A VI Scientific,Frequrcy:50Hz,Voltage:230-280V,operating time per test-10 min) as per Department incharge 392 Supplying of HaemometerSahli type-Microsidd (Specification:Amber coloured glass bottle -1 No.,Glass Stirrer-1 No.,Dropper with teat -1 No.,Cleaning Brush -1 No.,Spare latex tubing one meter -1 No.Round tube haemoglobinometer) as per Department incharge 393 Supplying of Anti - theft Sticker with the University logo as per Department incharge 394 Supplying of Middleware Application Desktop(Write and Read Tags) as per Department incharge 395 Supplying of RFID Staff Station or desktop reader (Used for tagging of books and circulation {lssue/Return) operations through RFID) as per Department incharge 396 Supplying of Integration with Software and Training of Complete RFID System as per Department incharge 397 Supplying of RFIDSecurityGates (2 pedestals-1 gate) RFID Security Gate (Single Lane) as per Department incharge 398 Supplying of Automated Book drop Box as per Department incharge 399 Supplying ofCabling. Casing. Wiring , Switches as per Department incharge 400 Supplying of Freight Transportation of Miidle ware Application Desktop,RFID STAFF Station,Integration with software training,Automated Drop box ,Cabling,Casing,Wiring,Switches as per Department incharge 401 Supplying of LAN . Switches, Necessary Cabling, Casing , Power Supply port including cables as per Department incharge 402 Supplying of Dedicated serverGHZ 16 core 1P-32GB -RP408ia -NC8SFF800WPS Serverintel Xeon -G5218 Kit for DL 380 GEN-10-HPE 32GB 2RX4 PC-4 2933YR Smart kit ,HPE DL38x Gen 10-12 Gb SAS Expande,HPE DL 380Gen 10 Box 1/2 Cage Bkpin kit ,HPE 24TB SAS 12G 10K SFF SC 512eDS HDD .HPE 800 WFS Ht Plg LHPwr Sply kit,HPE 3 Year Fiundation care 24x7 DL 380 Gen 10 Serviceas per Department incharge 403 Supplying of RS 86+_TB619RS, 3GB RAM and 48 GB ROM,4K Display Android model,3 GB RAM And 48 GB ROM,slim frame,Anti Glare Glass,3M Anti glare H7 Anti touch surface hardness lightweight for easy installation,Media suits for Annotation,Software bundled with education apps,Office suits,Great writing experience,Object recognition -First pal,/Fine pen ,Touch Points-20 points under window and 10 points under android,178 degree viewing angle IR ,Touch 15000,1 contrast ratio,4 MS Response time 50000 hours life,Reduce clutter and bring efficiency for the faculty,Remote control,15 wattX2 speaker,Android 8.0,Newline cast,Display management,Newline broadcast including installation and Trainingas per Department incharge 404 Supplying of Deep Fridgeas(2 in 1 Converti Freezer & Cooler Corrosion Resistant Cooling Coil & PPGI for inner & outer body Heavy Duty Compressor & Tropicalised Design Approximately 14% Higher Net Capacity compared to competition Sleek Design with heavy duty performance) per Department Incharge 405 Supplying of Autoclave (Horizontal,Height X Dia: 450mm x 250mm Height x Dia: 18Inch x 10Inch,Capacity: 22 Ltr,Load: 2.0 KW) as per Department Incharge 406 Supplying of Autoclave (Vertical): size- 400x600mm, Capacity- 75Ltr as per Department Incharge 407 Supplying of Hot air oven(Standard double wall fabrication. Inner chamber made of highly polished stainless steel sheet. Exterior fabricated out of thick mild steel sheet duly finished in stove enamel off-white paint or paste mat finish colour combinations.Nichrome wire heating elements -provided on three sides attain quick and uniform heating in range of 50c to 250c + 1c controlled by capillary type thermostat.Inner Chamber Size 18x18x18 inch. made of Stainless Steel) : any Standard make as per Department Incharge 408 Supplying of Bacteriological incubator(Item Weight ‎10 kg Product Dimensions-30 x 30 x 30 cm; 10 Kilograms,Item model number-12X12,Item Height-30 Centimeters Item Width-30 Centimeters) as per Department Incharge 409 Supplying of Bacteriological shaking incubator as per Department Incharge 410 Supplying of BOD incubator as per Department Incharge 411 Supplying of Laminar air flow any Standard company as per Department Incharge 412 Supplying of Micropipettes with microtips :(1.0uL-10.0uL, 10.0uL-100uL, 100uL-1000uL, 20uL-200uL): A. Prime Variable Pipette, B. Fully Autoclaveable Variable Vol. Pipetteas per Department Incharge 413 Supplying of Colorimeters with cuvettes any Standard company as per Department Incharge 414 Supplying of Western Blot apparatus, as per Department Incharge 415 Supplying of Powerpack with wiresas per Department Incharge 416 Supplying of Homogeniser as per Department Incharge 417 Supplying of PCR machine Block Formats 96x0.2ml(A),54x0.5ml(B), 96x0.2ml +77x05ml©, 384well(D) Size(WxDxH,mm)-380x270x250 as per Department Incharge 418 Supplying of UV Transilluminator/UV chamber UV source: 365nm Wave Length Viewing area: 24x14cm Anti Slip rubber foot provided for base as per Department Incharge 419 Supplying of CO2 incubator as per Department Incharge 420 Supplying of pH meter and buffers: A.pH meter B. pH buffers as per Department Incharge 421 Supplying of Water bath (any Standard company ) as per Department Incharge 422 Supplying of Fume Hood: size- 3x3x2 wooden with Granite working area as per Department Incharge 423 Supplying of Soxlet apparatus with heating mantle and distillation set up as per Department Incharge 424 Supplying of Kjeldahl Apparatus as per Department Incharge 425 Supplying of Ultrapure Water Purification System: MiliQ water as per Department Incharge 426 Supplying of Quebee Colony Counter as per Department Incharge 427 Supplying of Light Microscope (general) 25x, 45x, 100x s as per Department Incharge 428 Supplying of Bifocal microscope with illuminators as per Department Incharge 429 Supplying of Magnetic stirrer with magnetic beads(any Standard company )as per Department Incharge 430 Supplying of Magnetic stirrer with hot plate (Remi) as per Department Incharge 431 Supplying of Heating mantleas per Department Incharge 432 Supplying of Microwave oven ((20Ltr) as per Department Incharge 433 Supplying of Glass Dessicators as per Department Incharge 434 Supplying of Computer : Core i9, 7th Gen. 20 LED Monitor, 4GB DDV, 1TB HDD, DV writer HP/Dell as per Department Incharge 435 Supplying of Culture room: Tissue culture Rack fitted with 16 tubes, 8 bulbs, 4UV & Timer as per Department Incharge 436 Supplying of Electronic Analytical Balance:- Readability- 1mg(0.001g) Cap.-420gm as per Department Incharge 437 Supplying of ElectronicTop-pan Balance:-Readability- 0.1g Cap- 2kgas per Department Incharge 438 Supplying of Electroporator:- as per Department Incharge 439 Supplying of Fermenter(7.5L)(any Standard company )as per Department Incharge 440 Supplying of Fluorescence Microscopeas per Department Incharge 441 Supplying of Hot air oven universalas per Department Incharge 442 Supplying of Distillation Unit as per Department Incharge 443 Supplying of Membrane filter assembly 5000 mlas per Department Incharge 444 Supplying of Fluorimeter as per Department Incharge 445 Supplying of Homogeniser: Remi model- RQT-127 A/D High speed homogenizer, with 1/8 HP Motor, Homogenizer Working Volume [H2O] 0.1-50ml (Dispersing shaft DS-160/5) WEIGHT 0.6KG Dimension[LxWxH] 46mmx55mmx230 operating environment 0-40degre, 85% rel. humidity as per Department Incharge 446 Supplying of ELISA reader and Microtitre plates: ELISA Wavelength range 400nm-800nm Accuracy- +-1% at 1.0OD, 450nm Dimension 450x350x197mm as per Department Incharge 447 Supplying of Liminar air flow : 4x2x2 feet, stainless steel as per Department Incharge 448 Supplying of Gel Documentationd system as per Department Incharge 449 Supplying of 5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 450 Supplying of 12V/26AH- Batteryas per Department Incharge 451 Supplying of Headphone with built in microphone (Brand) as per Department Incharge 452 Supplying of Furniture:- Computer Table & Chairs & Table- Chair for lab. Instructor and student (50 students per batch) as per Department Incharge 453 Supplying of Network:- LAN, Switches, Cabling, Casing Power Supply Port including Cables as per Department Incharge 454 Supplying of 5.5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 455 Supplying of RS86+ TT8619RS 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0, Newline Cast, Display Managemen, Newline Broadcast Including Installation and Training. as per Department Incharge 456 Supplying ofpH meter(Digital) :- pH range: 0-14, Temperature Range: 0.0 to 100 C (Manual Compensation) as per Department Incharge 457 Supplying ofNoise Level meter:- Auto/Manual ranging from 30 to 130dB in 6 ranges as per Department Incharge 458 Supplying ofWater analysis Kit:- They include; alkalinity, chloride, hardness, iron, and sulphate as per Department Incharge 459 Supplying ofHigh volume sampler:- 1)PM-2.5- Designed to meet International Standards for High volume air Sampling of PM2.5 particulates. 2)PM-10-U.S EPA FRM Designed for the determination of suspended of PM-10 particulates concentrations. (RFPS-1287-063) 3)TSP- Designed to meet U.S EPA reference method for determination of total suspended particulates(TSP) concentration as perDepartment Incharge 460 Supplying ofSoil testing kit (mrinda parikshan kit) : Use for micro and macro nutrients as per Department Incharge 461 Supplying ofSeive plate with shaker : 5mm,1mm,2mm) as per Department Incharge 462 Supplying ofUV/Visible spectrophotometer:- Spectral bandwidth 1 nm (190 to1100nm , Lamp Type 20-W halogen lamp and deuterium lamp as per Department Incharge 463 Supplying ofAutoclave : 10-15 litre Steam Sterilizer as per Department Incharge 464 Supplying ofLaminar hood (Horizantal) : Horizontal air flow cabinet, filter air blow across the work zone in horizontal direction. This constant flow of air provides material and product protection as per Department Incharge 465 Supplying ofHot plate(pic):-Temperature range: 350 C as per Department Incharge 466 Supplying ofShakeer incubator Compact Bench top shaker with temperature control range from Ambient +50C to 600C. Tray dimension : 420x420 , Speed 50-350 rpm with accuracy of +/- 2rpm as per Department Incharge 467 Supplying ofMuffle Furnaces (15x125x250)cm: Temperature upto 35C to 1400C as per Department Incharge 468 Supplying of Analytical Balances:Capacity 220gram as per Department Incharge 469 Supplying ofDigester : 1) vessel size : Dia 39 mm (Aprox.); Volume 160ml 2)Temperature : upto 200degC as per Department Incharge 470 Supplying ofDouble distilled water plant: Model- Vertical:- Distlled Water Output Capacity-2.5 Litres/Hours, Distillate water quality as per Department Incharge 471 Supplying ofOven:- Dry ovens- 30 to 1000 litre capacity. as per Department Incharge 472 Supplying of B.O.D Incubator: Volume 68 Litre as per Department Incharge 473 Supplying ofMagnus Microscope:- Magnification 4x,10x,40x, and 100x as per Department Incharge 474 Supplying ofDesiccators:- Contain: Silica Gel dimension;12x12 in (30.5x30.5 cm),Material Glass as per Department Incharge 475 Supplying ofRichter scale hardness tester Portable Rockwell/brinell vickers Hardness Testing Instrument Mold metal hardness meter display:-parameter- HRC Display Type, Digital Model Name/Number- ATedigiHR, Accuracy- 0.1 HRC Dimensions of Machine base (approx.) 150x425 mm as per Department Incharge 476 Supplying ofProctor Penetrometer: Proctor Penetrometer- Complete with set of needle points Weight, 2 kg as per Department Incharge 477 Supplying ofGas Chromatography Retention time repeatability-< 0.008% or 0.0008 min Area rpeatability -<1% RSD, using 2ng tetradecane as per Department Incharge 478 Supplying of Atomic Absorption Spectrometry(AAS):- aa-7000 SERIES OF Atomic Absorption Spectrophotometers features high- sensitivity analysis as per Department Incharge 479 Supplying ofWavelength range; 400 to710nm Wavelength selection: 8 in-built gelatin filters: 430,470,490,520,540,580,600 and 710 nm Measurement ranges; 0-100%T, 0-1.50Abs, 0.1 to 1000 Concentration. Resolution: 1%T, 0.01Abs, 0.1 to 1 Concentration as per Department Incharge 480 Supplying of Laptops(of Specification:Processor Corei5,RAM:4GB,Hard drive:500GB ,Screen size:12 inch):as per Department Incharge 481 Supplying of Desktops: i7 3rd Gen, 1TB HDD, 4GB RAM, Windos 10, MS office, Graphics card as per Department Incharge 482 Supplying of Xerox Machine(Product Specification:Functions Multi-Function:Supported Paper Size-A3,Supported OS-all,Color Output-Black & White,Number Of Trays-4,Item Color-white and blue Print Speed-up to 35 ppm,Weight 129 kg,Print Technology-Laser Warm-Up Time, As fast as 11 seconds (black and white) Duty Cycle-WorkCentre 5335: Up to 150,000 pages / month Resolution-200 x 1200 dpi) as per Department Incharge 483 Supplying of Air Conditioning:-1.5 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 484 Supplying of Luminous Cruze 3.5KVA Inverter with RC 18000 Battery (4 Batteries) as per Department Incharge 485 Supplying of Projector(Special Feature-portable,Connectivity Technology,Bluetooth, Wi-Fi, USB, HDMI,Display resolution 1920 x 1080,Display Type-LED) as per Department Incharge 486 Supplying of Godrej Lecture Hall Furniture as per Department Incharge 487 Supplying of Electronic Podium(Speaker type-Tweeter,Auxillary,wireless,floor standing) as per Department Incharge 488 Supplying of Smart board (Screen size-11 inches,Connecting technology-Wifi,Multimedia)as per Department Incharge 489 Supplying of Black board( Melamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS CornersMelamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS Corners) as per Department Incharge 490 Supplying of Glassware rack as per Department Incharge 491 Supplying of installation of Air conditioner,Luminous Cruze,Projector,Lecture Hall Furniture,Electronic podium,Smart board and black board as per Department Incharge 492 Supplying of Inductively coupled Plasma - Optical Emission Spectrometer with CID detector technology for multi-element analysis of geological petrogical etc. samples in ppb level as per Department Incharge 493 Supplying of Suppressed ion analysis system for anion and cation analysis in water, wastewater, environmental samples and also upgradable to combustion for determination of corrosive halogens and sulfur in Petrochemicals, gaseous samples, solid samples, and complex samples as per Department Incharge 494 Supplying of CHNS/O for the analysis of Carbon, Hydrogen, Nitrogen, Sulfur and Carbon in organic matrices, soil, feed , plant samples, petroleum products, Coal, Coke, Biomass & Liquid Fuels as per Department Incharge 495 Supplying of Gas Analyzers for hydrocarbon and permanent gas analysis as per Department Incharge 496 Supplying of Benchotop XRD as per Department Incharge 497 Supplying of XRF Spectrometer as per Department Incharge 498 Supplying of Refrigereted Centifuge MakE-REMI, Model-C24 PLUS :- Max. Speed:20000, Max. RCF:3757, Max. Lowest Temp.:8, Noise:60db. Essential accessories Required: 01. Withangle Heads (with polypropulene tubes) Model-R-248M24x1.5ml 2)Voltage stabilizer:-03KW Servocontrolled Voltage Stabilizer, input 170volts to 260volts, output 220 to 240volts as per Department Incharge 499 Supplying of pH Meter compatible poer bank Make: REMI :- With eletrode as per Department Incharge 500 Supplying of Bench top Centrifuge Make: Tarson, : - SPINWIN MC-001 6 places Rotor for 1.5 ml tubeas per Department Incharge 501 Supplying of Deep Fridge: It is used to store chemicals and preserve samples at very low sub-zero tempertures or below as per Department Incharge 502 Supplying of Autoclave(Vertical) : size- 400x600mm capacity- 75Ltr as per Department Incharge 503 Supplying of Hot air oven : Sterilization as per Department Incharge 504 Supplying of Incubator Shaker: Growth and enumeration of microbes(Broth Cultures) as per Department Incharge 505 Supplying of Horizontal Laminar air flow:- Sterile environment size 4x2as per Department Incharge 506 Supplying of Ultrapure Water Purification System: MiliQ Water : for distil water as per Department Incharge 507 Supplying of Micropipets (Ependroff): 0.1uL-2.5uL, 0.5uL-10uL, 10.0uL-100uL, 100uL-1000uL each oo these 1pcs as per Department Incharge 508 Supplying of Light Microscope (general)10X, 20X, 45X, 100X, : Visualize microorganisms as per Department Incharge 509 Supplying of Bifocalcal Microscope with illuminators, Camera Attachment and comput: Visuallize microorganisms and micrography as per Department Incharge 510 Supplying of Magnetic stir with Hotplate and magnetic bead as per Department Incharge 511 Supplying of Heatingmant; for heatinground bottomed flask/distillation flask as per Department Incharge 512 Supplying of Microwave oven: To heat liquids instead of flaming. 20Ltrs as per Department Incharge 513 Supplying of kydroPro 100 handeld multiparameter water quality analiser: Turbedityas per Department Incharge 514 Supplying of Petrological Microscope: Study of Optical minrology as per Department Incharge 515 Supplying of Ore petrological microscope: Study of ore petrology as per Department Incharge 516 Supplying of Miscellaneous instruments as per Department Incharge 517 Supplying of glassware as per Department Incharge 518 Supplying of chemical as per Department Incharge 519 Supplying of Arc GIS(Latest) as per Department Incharge 520 Supplying of GCD Toolkits as per Department Incharge 521 Supplying of SURPAC Software as per Department Incharge 522 Supplying of Intergraph Edu Kit [GIS+RS] Version 2020 or latest(Software content as per list), 5 users for Erdas imagine Professional and 5 users for Geomedia professional Software as per Department Incharge 523 Supplying of Interactive Flat Panel as per Department Incharge 524 Supplying of 2 Virtual Class Room including capture, recording and streaming online, 1 Servers one per 05 classrooms per Department Incharge 525 Supplying of N-computing for smart classrooms including servers and clients as per Department Incharge 526 Supplying of Tagging of documents(books/hard-bound journals/CDs/technical films etc)in RFID Technology as per Department Incharge 527 Supplying of Sofwares, Server Machines, Air-Conditioning Systems,Xerox Machines, Lamination Machines, Binding Machines, Furniture/Furnishing, Computers, Printers etc as per Department Incharge 528 Supplying of Digital Podium, PTGN 500, Window & 1 LCD, Elecronic Lectern, on site OEM. Warranty 3years, 3GB RAM,4GB ROM as per Department Incharge 529 Supplying of Air Conditioning:-1.8 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 530 Supplying of Black/ White,Printer:- scan-copy all in printer- Branded as per Department Incharge 531 Supplying of CCTV set for floor: 55 LRD display for CCTV. CCTV Camera-1 P based CCTV camera 2TB space with NVR with necessary accessories as per Department Incharge 532 Supplying of 5KVA Inverter online UPS with battery backup 100Mah battery(8 units) as per Department Incharge 533 Supplying of Electrophoresis Apparatus as per Department Incharge 534 Supplying of Bacteriological Incubator as per Department Incharge 535 Supplying of Autoclave as per Department Incharge 536 Supplying of Centrifuge as per Department Incharge 537 Supplying of Rotar Head as per Department Incharge 538 Supplying of Rotar Head 25 as per Department Incharge 539 Supplying of Gel documentation system as per Department Incharge 540 Supplying of Spectrophotometers as per Department Incharge 541 Supplying of compoud Microscope as per Department Incharge 542 Supplying of Trinocular Microscope with camera as per Department Incharge 543 Supplying of Semi-Automated Microtonne as per Department Incharge 544 Supplying of DNA Sequencer as per Department Incharge 545 Supplying of Spectrophotometer as per Department Incharge 546 Supplying of Laminar air flow chamber as per Department Incharge 547 Supplying of Tissue culture rack as per Department Incharge 548 Supplying of PCR Apparatus as per Department Incharge 549 Supplying of Liquid nitrogen cylinder as per Department Incharge 550 Supplying of TLC apparatus kit as per Department Incharge 551 Supplying of TLC Visualizer/documentation as per Department Incharge 552 Supplying of HPLC System as per Department Incharge 553 Supplying of Scientific vortex mixer as per Department Incharge 554 Supplying of Soil Thermometer as per Department Incharge 555 Supplying of Scientific Digital Balance as per Department Incharge 556 Supplying Equipments for workshop,Seminar & Excrusion as per Department Incharge 557 Supplying Equipments for Non-Recurring(Research Equipment) as per Department Incharge 558 Supplying Equipments for Recurring(Chemical & Glassware) as per Department Incharge 559 Supplying of Furniture Bookshelves, Study Tables and Chairs for Readers as per Department Incharge 560 Supplying of Desktop i5 Processor, 7th Generations, 500GB HDD, 4GB RAM, 23.8 inch, LED backlit Monitor Full HD IPS Panel (Brand: HP/DELL) as per Department Incharge 561 Supplying of Headphone with built in microphoneas per Department Incharge 562 Supplying of Printer with scanner (Laser,Colour/B/W)as per Department Incharge 563 Supplying of Scanner(USB,25.2D x 36.8W x 4.3H Centimeters,Slide) as per Department Incharge 564 Supplying of Xerox Machine:- (,Platen cover & Toner, Resolution (DPI):1200 X 1200dpi, Duty Cycle:1.3 Sec) as per Department Incharge 565 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-500mm,Laminating speed-1200mm)as per Department Incharge 566 Supplying of CCTV Camera(Full HD Picture,AI Powered Motion Detection,Infrared Night Vision; 360° Panorama,Talk Back Feature (2-Way Audio)Material Type: Plastic; Included Components: Camera, Power Adapter, Charging Cable, Wall Mounting Kit, User Manual; Specific Uses For Product: Surveillance) as per Department Incharge 567 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 568 Supplying of RS75+ TT7519RS RS 75+ comes with 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management. as per Department Incharge 569 Supplying of Wall Mount Kit(Material: SS,Max loading capacity-60 to 100kg) as per Department Incharge 570 Supplying of Live streaming software Software Software for Live Streaming or Live telecast as per Department Incharge 571 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 572 Supplying of Frieght Transportation of 4K Display,Wall mount kit,Live Streaming software as per Department Incharge 573 Supplying of cctv solutions for Department with 20 cameras(Image Sensor Type-CMOS,Image Sensor Size-0.357 inch,Camera Image Sensing capacity (Picture Mode)-2MP,Resolution-Full HD (1920 x 1080 Pixel)-Day/Night Capable-Yes,IR illumination Range(mtr) 200 Type of Camera HousingDOME CAMERA,IP Camera Yes) as per Department Incharge 574 Supplying of installation and commisioning of CCTV and other computer equipment as per Department Incharge 575 Supplying of 55 Tv for seeing all cctv in HOD room as per Department Incharge 576 Supplying of8 PORT EPBX as per Department Incharge 577 Supplying ofTELEPHONE as per Department Incharge 578 Supplying ofWIRE as per Department Incharge 579 Supplying of CRON BOX as per Department Incharge 580 Supplying ofSWITCHES FOR PORTS as per Department Incharge 581 Supplying of Workststion Table, Chairs, Desktop, UPS as per Department Incharge 582 Supplying of LAN, Switches, Necessary Cabling, Casing Power Supply Port including Cables as per Department Incharge 583 Supplying of Refrigerator(Storage & Interior Description : | Cooling Type ; Frost Free | Display Type ; Thermostat | Shelf Material ; Toughened Glass | Compressor Type ; Reciprocatory)as per Department Incharge 584 Supplying of Microwave(Special Features: Quartz Heater - Concealed Heating. Safer Cooking, Stainless Steel Cavity - More Hygienic. More Durable, Child Lock - Ensures complete safety especially for homes with young children, Interior light)as per Department Incharge 585 Supplying of Washing Machine( Fully automatic 6 kg) as per Department Incharge 586 Supplying of Sewing Machine(Motorised)as per Department Incharge 587 Supplying of Weighting Machineas per Department Incharge 588 Supplying of Blood Pressure Monitor as per Department Incharge 589 Supplying of Oximeter as per Department Incharge 590 Supplying of Gluco Meter as per Department Incharge 591 Supplying of Test Tube & Breakers as per Department Incharge 592 Supplying of RO Water Purifier as per Department Incharge 593 Supplying of Microscope(Student) as per Department Incharge 594 Supplying of Crockery Set as per Department Incharge 595 Supplying of Cocking Utensils set as per Department Incharge 596 Supplying of Cutlery Set as per Department Incharge 597 Supplying of Sofa Set + Centre Table as per Department Incharge 598 Supplying of A.C (Split 2 Ton,3 Star,Twin invertor HD Compressor)as per Department Incharge 599 Supplying of Stabilizer(Automatic Voltage Stabilizer,37.4 x 27.1 x 19.8 Centimeters,5 kg 700 g)as per Department Incharge 600 Supplying of Inveter with battery(Capacity -100AH,Battery Type-Tubular Battery,Warranty-1 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 1 FAN ,28 Light , 8 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 601 Supplying of Desktop Computer with UPS and Computer Tableas per Department Incharge 602 Supplying of Original operating system software window 10 with Antivirus as per Department Incharge 603 Supplying of Printer with scanner (inkjet,Colour/B/W)as per Department Incharge 604 Supplying of Dining Table Set as per Department Incharge 605 Supplying of Camera as per Department Incharge 606 Supplying of Mixer Grinder as per Department Incharge 607 Supplying of Iron as per Department Incharge 608 Supplying of Wall Clockas per Department Incharge 609 Supplying of Whole tailoring Equipments (Local) as per Department Incharge 610 Supplying of Knitting Equipments(Local) as per Department Incharge 611 Supplying of Flower Arrangement Equipments) (local) as per Department Incharge 612 Supplying of Aluminium Set as per Department Incharge 613 Supplying of Plastic Tub as per Department Incharge 614 Supplying of Dustbin(Big) as per Department Incharge 615 Supplying of Basket &Mug as per Department Incharge 616 Supplying of White Table Cloth(Big size)as per Department Incharge 617 Supplying of Wash Basin(Local)as per Department Incharge 618 Supplying of Gas Stove +Cylinderas per Department Incharge 619 Supplying of Curtains(Local) as per Department Incharge 620 Supplying of Floor Mats (Local) as per Department Incharge 621 Supplying of Tube Lightas per Department Incharge 622 Supplying of Fan as per Department Incharge 623 Supplying of Led Projector(New Edition)as per Department Incharge 624 Supplying of Smart Board(specification:white,power consumption<150w ,usage-school,Effective touch-65x46) as per Department Incharge 625 Supplying of Decorative Items(Local) as per Department Incharge 626 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 60 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 15000 ppm,Features-Two-sided printing,Weight-25kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scanner multi as per Department Incharge 627 Supplying of Ceiling Fanas per Department Incharge 628 Supplying of Exhaust Fan as per Department Incharge 629 Supplying of Pedestal Fan as per Department Incharge 630 Supplying of Inveter with battery(Capacity -200AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 14 Hrs Backup- 4 FAN , 8 Light , 14 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 631 Supplying of Wooden Stool(Local) as per Department Incharge 632 Supplying of Wash Basin (Local) as per Department Incharge 633 Supplying of Register (Local) as per Department Incharge 634 Supplying of Stabilizer for ACas per Department Incharge 635 Supplying of Tubelightas per Department Incharge 636 Supplying of Dustbin (Local) as per Department Incharge 637 Supplying of Curtains (Window and Door) (Local)as per Department Incharge 638 Supplying of Door Mat(Local) as per Department Incharge 639 Supplying of Broadband(Wifi)as per Department Incharge 640 Supplying of Furniture Bookshelves, Study Tables and Chairs for attendant and students (30 students at a time) as per Department Incharge 641 Supplying of Wireless mic as per Department Incharge 642 Supplying of Weight Box(100g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 643 Supplying of Weight Box(50g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 644 Supplying of Kymograph :-with smoked paper, smoked Drum, Time marker as per Department Incharge 645 Supplying of Memory Drum :- Electrical operated as per Department Incharge 646 Supplying of Memory Drum :- Hand operated as per Department Incharge 647 Supplying of Metronome :- Mechanical as per Department Incharge 648 Supplying of Porteuz Maze Test as per Department Incharge 649 Supplying of Techisto-scope :- Fall Drop type as per Department Incharge 650 Supplying of Techisto-scope :-Electronic as per Department Incharge 651 Supplying of Verniers chronoscope :- Pendulum Type as per Department Incharge 652 Supplying of Ergograph/Smoke drum /smoke paper varshing tray and varnish :- Hand grip model as per Department Incharge 653 Supplying of Weight 6Kg as per Department Incharge 654 Supplying of Multiplication sheets(100sheet) as per Department Incharge 655 Supplying of Screen:- Wooden as per Department Incharge 656 Supplying of Ravens Progressive Matrices as per Department Incharge 657 Supplying of Weschlers Intelligence scale (Adult) as per Department Incharge 658 Supplying of Cattles 16 PF Questionnaire as per Department Incharge 659 Supplying of Jungs Word Association Test as per Department Incharge 660 Supplying of Thematics Apperception Test as per Department Incharge 661 Supplying of Zeigarnik Effect Test as per Department Incharge 662 Supplying of The Occupational Stress Index(OSI) Scale by A.K Shrivastawa and A.P. Singh as per Department Incharge 663 Supplying of Rorschach Test as per Department Incharge 664 Supplying of Coping Strategies Test by A.K. Shrivastava as per Department Incharge 665 Supplying of Job Satisfaction scale(JSS) by Amar Singh and T.R. Sharma as per Department Incharge 666 Supplying of Job Involvement Scale by A.K. Singh and R. Kapoor as per Department Incharge. 667 Supplying ofOrganizational Climate Scale by Somnath Chatopadhya and K.G. Agarwal as per Department Incharge 668 Supplying of Managerial Aptitude Scale(MAS) by Santosh Dhar, Upinder Dhar and Priyanka Sharma as per Department Incharge 669 Supplying of Employees Motivational Scale by A.K. Shrivastava as per Department Incharge 670 Supplying of Employees Mental Health Inventory (EMHI) by Jagdish as per Department Incharge 671 Supplying of Beck Depression Inventory by Arron Beck as per Department Incharge 672 Supplying of Aggration Scale (AS) by G.P. Mathur and Rajkumar Bhatnagar as per Department Incharge 673 Supplying of Ego Strength Scale by Q. Hassan as per Department Incharge 674 Supplying of Bells Adjustment Iventory by S.M. Mohsin and Shamshad as per Department Incharge 675 Supplying of Marital Adjustment Questionnaire by P. Kumar and kanchan Rohtagi as per Department Incharge 676 Supplying of Sacks Sentence Completion Test as per Department Incharge 677 Supplying of PGI Health Questionnaire N-1 (PGIHQN) by S.K. Verma, N.N. Wig and D. Prasad as per Department Incharge 678 Supplying of Rotters Locus of Control Scal by Anand Kumar and S.N Srivastava as per Department Incharge 679 Supplying of Self Concept Inventory by O.N Srivastava as per Department Incharge 680 Supplying of PGI Social Support Scale by S.K. Verma, P. Kulhara and Ritu Nehraas per Department Incharge 681 Supplying of Emotiobnal Maturity Scale(EMS) by R.R. Trtipathi as per Department Incharge 682 Supplying of Life satisfaction Scale(LSS) by Q.G. Alam and R. Srivastava as per Department Incharge 683 Supplying of PGI Quality of Life Scale by S.K Verma and A.C. Moudgil as per Department Incharge 684 Supplying of Environmental Awareness Scale (EAS) by Haseen Taj as per Department Incharge 685 Supplying of Jatota Test of Group Mental ability as per Department Incharge 686 Supplying of Weinsteins Noise Sensitivy Scale (WNSS)(Shore Samvedi Mapak) by P. Bhatia, S. Mohar and I.S Mohar as per Department Incharge 687 Supplying of State Traight Anxiety Test (STAT) as per Department Incharge 688 Supplying of Xerox Machines (Digital)(Product Specification:Copy | Print | Scan | Fax,Number Of Trays-2,Item Color-Black,Duty Cycle-20000,Print Technology-LaserPrint Speed-25 Paper Per Minute ) as per Department Incharge 689 Supplying of Binding Machine (Product Specification:Capacity-12-15 Sheets,Binding Style-Manual ,Max Binding Thickness<20 mm Max Binding Sheet Width 200-300 mm,Automatic Grade-Semi-Automatic,Weight-5.8Kgs Approx.,Dimension-375x230x150mm Approx.Automation Grade,Hole Size-3x8mm,Paper Size-A4 /Letter /A5 etc,Packaging Weight-375 mm,Handle Type-metal,Packaging Size-375x230x150mm Approx.Adjustable Margin-2.5/4.5/6.5mm,Usage/Application-Comb Binding Method Of Operation-Manual,No Of Punch Holes-21 holes Number Of Punch Slots-21 holes,Size-A4,Number Of Punch Holes-21 holes,Machine Dimension-375x230x150mm Approx.Is It Padded)as per Department Incharge 690 Supplying of Printers(Ink End Sensor-yes,paper storage capacity-100 sheets Paper Input, 50 sheets Paper Output-printing technology ink tank,connecter type-Wi-Fi, USB,special feature-Cost per print - 9 paise (Black & White), 33 paise (Colour) as per Department Incharge 691 Supplying of Furnishing (Book shelves:Study table and chair)as per Department Incharge 692 Supplying of Book Case(for Psychological Tests) as per Department Incharge 693 Supplying of Open Racks as per Department Incharge 694 Supplying of Inveter with battery(Capacity -150AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 2 FAN , 2 Light , 12 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 695 Supplying of Inverter with Battery(Capacity-150,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit Backup Time-5hrs,Battery Condition-New)as per Department Incharge 696 Supplying of Desktop(Product Specification:Hard Drive Capacity-320GB,Operating System-Window,Screen Size-17 inch Processor-i5,Display Type LCD Processor) as per Department Incharge 697 Supplying of Tally sofware (Multi User) as per Department Incharge 698 Supplying of Barcode Machine(Product Specification:Type-Thermal Printers,Max Printing Size-10 IPS,Resolution (dpi)-203dpi Model/Type-Citizen CLS-700,Automatic Grade-Fully Automatic Print Line-1~3 Lines) as per Department Incharge 699 Supplying of Server Machines(Product Specification:Memory-1x16 GB RAM/ Open Bay- 2.5 Hot Swap SAS/ SATA,Power Supply 220 V,Networking Type-LAN,Number Of Ports/Channels-8 USB Port-Yes Processor Speed Intel Xeon Silver 4114 (Deca Core) 2.2GHz Power Consumption 750 W) as per Department Incharge 700 Supplying of LAN connection between 7 computers as per Department Incharge 701 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 30 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 10000 ppm,Features-Two-sided printing,Weight-16.8kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scannercannon image Class MF641CW multi as per Department Incharge 702 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-330mm,Laminating speed-600mm)as per Department Incharge 703 Supplying of Binding Machine (Punches-43 holes,Hole distance-43 holes in A 11 SHEET,Binding sizes:Max 11) as per Department Incharge 704 Supplying of Computers (Processor -AMD Ryzen 3,RAM-8GB,HDD-512 GB,screen size-19.5 inches,Operating system:Windows 11 )as per Department Incharge 705 Supplying of Office Computer (Processor:i5 10th,HDD:1 TB,RAM-4 GB,GT730 4GB Graphics) as per Department Incharge 706 Supplying oflaser printer(Product Specification:Color Output-Black & White,Function-Print | Scan | Copy,Max. Print Speed (Black)-18 ppm Max. Print Speed (Color)-17 ppm,Connectivity-Ethernet,Paper Size-A4,Print Volume-Up to 500 pages/month) as per Department Incharge 707 Supplying of Smart class Board(Power consumption:220-300V,size/Dimension-65,Input type-finger Touch) per Department Incharge 708 Supplying of Double battery(capacity-250Ah,Over current protection) Inverter(Back up time-5 hrs) as per Department Incharge 709 Supplying of Desktop Computers :- HP 23.8-inch FHD All in One Desktop with Alexa Built-in(10th Gen Intel Core i3- 1005G1/8GB/512 GB SSD/Windows 10/MS Office 2019/Natural Silver), 24-dp0816in as per Department Incharge 710 Supplying of Printer, ScannerMulti-Function Direct Wireless Network Laser Printer (Print, copy, scan, Black) as per Department Incharge 711 Supplying of Networking (LAN, leased lines, wi-fi, switches etc.) TP-Link Archer C6 Gigabit MU-MIMO Wireless Router, Dual Band 1200Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas and 1 Internal Antenna WiFi Coverage with Access as per Department Incharge 712 Supplying of Back up support(UPS, Generator, Transformer):-600VA UPS for Desktop/PC/Computers(not for Routers) with Automatic Voltage Regulation as per Department Incharge 713 Supplying of Xerox Machine:- (IR2004 With Duplex, Platen cover & Toner, Resolution (DPI):600 X 600dpi, Duty Cycle:4.3 Sec) as per Department Incharge 714 Supplying of IBM SPSS(Statistics Package Latest Version) as per Department Incharge 715 Supplying of Nvovo(Package) as per Department Incharge 716 Supplying of LCD Projector:- 1)Project movies,images or data from your devices,most effective in dark settings 2)Projector, Lens Cover/Stand, Carrying Pounch, USB Cable 3) Connect via Wi-Fi to Android smartphones and tables or connect HDMI to iPhone or iPad as per Department Incharge 717 Supplying of Projector Screen:- 1)10 Feet x 6 Feet, 133 Dia, 16:9 Format, UHD-3D-4K 2)Comes with FULL HD 1080P 3D and 4K Viewing Technology, Anti UV coating as per Department Incharge 718 Supplying of DTH connection:- 1)HD Set Top Box 2)Recording facility as per Department Incharge 719 Supplying of Television Set:- 1) Smart LED TV-42 inches 2)4K UHD (Resolution:3840x2160) 3)Connectivity-Input:3*HDMI,3*USB 4)Audio:20W output 5) 4K HDR provides exceptional clarity 6)Smartphone connectivity : Photo sharing plus, screen mirroring as per Department Incharge 720 Supplying of as per Desktop:- Intel i7, 8th Gen, 4GB N-Vidia Geforce Graphics card, 16 GB RAM, Monitor, CPU, Mouse, key board partment Incharge 721 Supplying of Multifunction Laser Printer,Scanner, and Copier :- Functionality: Print, Scan,Copy Print Technology : Monochrome Laser Connectivity: Hi-speed USB, Compatible with USB 2.0 Specifications4as per Department Incharge 722 Supplying of Speaker 7.1 surround stereo(Power -100W,Play tme-11 hours,Voice Range-9m) as per Department Incharge 723 Supplying of Digital SLR Camera: 1)EOS full HD movie mode with movie service 2)18 megapixel CMOS)APS-(sensor 3)14-bit A/D conversion 4)ISO 100-12800)EXPANDABLE TO h:25600(5)Dual Lens camera 55-250mm IS II lens 6) Camera battery charger and bag 7)Wide strap USB cable, software CD. as per Department Incharge 724 Supplying of 24.2MP DigitalSLR Camera:- 1)100% Viewfinder Coverage 2)CMOS sensor with impressive high-resolution result 3)Camera battery, charger, and bag 4)Wide strap USB cable, software CD, manual as per Department Incharge 725 Supplying of Quark express as per Department Incharge 726 Supplying of Adobe Suite(CS6 Master Collection) as per Department Incharge 727 Supplying of Cool Edit Pro as per Department Incharge 728 Supplying of Turnitin as per Department Incharge 729 Supplying of Sound Forge as per Department Incharge 730 Supplying of 18-55mm normal lens as per Department Incharge 731 Supplying of 55-250mm Zoom lens as per Department Incharge 732 Supplying of 18-135mm lens as per Department Incharge 733 Supplying of 35mm prime lens as per Department Incharge 734 Supplying of 80mm macro lensas per Department Incharge 735 Supplying of Tripods as per Department Incharge 736 Supplying of DSLR:- 1)Powered by NP-F570 InfoLithium rechargeble battery pack 2)Records to MiniDV tape stock 3)16:9 widescreen recording 4)3CCD video camera 5)12x optical zoom lens 6)Records to MiniDV tape stock as per Department Incharge 737 Supplying of:- 1)3CCD video camera 2) Crystal Engine 3)Shoulder -Type Design 3)One Touch Navigation 4)Manual Focus Ring 5) 0 lux colour light view 6)10x optical zoom 6)500x digital zoom 7)Super image stabilizer 8) DV IN/OUT Terminal 8)5-mode programme AE: sports, portrait, low light, spot light, and surf &snow 9)SP/I.P recording 10)Back light compensation 11) Cinema mode )16:9 aspect ratio( 12)Infra-red remote controller as per Department Incharge 738 Supplying of Tripods:- 1)3-way head with adjustable pan 2)Steady rubberized legs 3)Multipurpose head with quick release 4)Multipupose head for DV cameras 5)Made from High Grade Aliminium Alloy 6)Quik flip leg locks 7)Fluid pan&tilt movement 8)Quik release plate& Bubble Level as per Department Incharge 739 Supplying of i-Mac(Product Specification,Storage Capacity-256 GB Display-24 inch,Memory Size-256gb ssd,assembled Product Dimensions L X W X H,461 mm x 547 mm x 130 mm, 4.48 kg Color-Silver & Blue,Graphics-8_core GPU,Video Support And Camera 4.5K,Bluetooth-Bluetooth 5.0,Weight-4.48kg,Operating System-macOS Big Sur,Processor- M1Echip,Line Voltage-100-240V AC) for Video Editing as per Department Incharge 740 Supplying of Photographic Design Flash Bender-Small Reflector:- 1) Make a bounce flash reflector, gobo, or snoot 2)Packs flat/great for travel 3)Attaches quickly & securely 4)Adjustable to fit all popular brands of accessory flash 5)For on-camera or off-camera flash as per Department Incharge 741 Supplying of Rim Collapsible softbox Diffuser with Rim :-1)Softbox 36 inches/90 Centimeters with Grey Rim and Bowens Mount, Portable and Quick Folding Softbox Diffuser for Photography Speedlites Flash Monolight 2)for 660 LED Panel-Outer 16.3x6.5 inches,Inner 9.8x8.7 inches Collapsible Light Reflector 3)with Stap Attachment and Carrying Bag for Photo Studio Portrait Video Shooting as per Department Incharge 742 Supplying of Handheld Camera Stabilizer with Quik Release for DSLR:- 1)Light weight, handheld video image stabilization 2)FlyCam 3000 video cam stabilizer accepts camera upto 3.5kg/7.7Ibs. 3)Easy attach a small LCD monitor with Flycam 3000 cam stabilizer when needed. 4)Precision Aluminum made 5)23 tall and just 207 Ibs without counter balance disc. as per Department Incharge 743 Supplying of Green/Blue matte screen )Chroma key( :- 1)8x12 ft Blackboard, perfect for television, video production and digital photography. 2)Rod pocket on each top edge allows to be draped or hung. 3)Finishing along all edges to prevent tears. 4)Made of 100 %pure cotton, good vertical sense and durable as per Department Incharge 744 Supplying of Professional Grade Backdrop Cum Light Stand of 8 Feet Height:- 1)Photography Backdrop Stand Kit. 2)Stand of 8 Feet Height 3)8x12 ft Blackboard, perfect for television, video production and digital photography. 4) Package Contents; 1Pcs White Backdrop , 1Pcs Black Backdrop and Set of Black Backdrop stand. 5)Bag to carry as per Department Incharge 745 Supplying of Video Mixer (Four Channel Digital Video Mixer With Effects, including installation and training):- 1) four channel video mixer by incorportating HDMI inputs/outputs, USB streaming, HDCP support, built-in touch multi-viewer, and audio embedding . 2)(3Input)SD HDMI/Composite +(1Input) Up to1080p HDMI/RGB/Component/Composite. 3) PGM Output) Up to 1080p HDMI + RGB/Component +Composite +(PVW Output)PVW/Multiviewer(. 4)480p/576p Progressive internal processing 5.) Built-in multi-viewer ith touch control 6). Built-in frame synchronizers on all inputs 7). Scalers on CH 4 and Output 8). 259 Transitions 148 Effects 9). HDCP Compliant 10) Audio Embedding 11) Audio Mixer & Delay -up to 4 Fframes 12) USB Streaming Out for web-streaming 13) Video Processing:4:2:2 )Y/b/Pr(8 bits)Internal Processing :480/59.94p when set to NTSC, 576/50p when set to PAL( 14) Input Formats :HDMIVideo: INPUT 1 to3 : reqyires 720x480/59.94p )when set to NTSC( 576/50p ) When set to PAL(15) Input Formats : HDMI and Component Video : INPUT 4:480/59.94p, 720/59.94p, 1080/59.94i, 1080/59.94p )when set to NTSC (576/50i, 576/50p, 720/50p, 1080/50i, 1080/50p )when set PAL( as per Department Incharge 746 Supplying of Studio Condenser Microphone :- 1)Professional, large-diaphragm condenser microphone for unsurpassed audio quality 2) Idea as Mian and support microphone for studio and live applications. 3) Cardioid pickup pattern for outstanding sound source separation and feedback rejection 4)Pressure-gradient transducer with shock-mounted capsule. 5)Ultra-low noise, transformerless FET inputeliminates low-frequency distortion. 6) LED indicates phantom power operation. 7)Swivel stand mount and transport case included. 8)Ultra-rugged construction with metal die-cast body 8)Gold-plated 3-pin XLR output connector for highest signal integrityas per Department Incharge 747 Supplying of Digital Monitor/Speaker System(in Pair) :- 1)Two-way active monitor system for multimedia workstations and keyboard monitoring 2)High-power woofers and tweeters powered provided a linear frequency response 3)optical and coaxial inputs to directly connect digital audio sources via S/PDIF interface 4)Two stereo analogue inputs featuring 1/8 TRS and stereo RCA connectors can be used simultaneously or mixed with a digital stereo source 5)Features 1/4 TRS headphone connector with auto-mute function easily accessible from the front panel 6)2x Stereo Anaog Inputs )TRS and Stereo RCA Connectors( 7) 1/4-inch TRS headphone connector with Auto-mute Loudspeaker Function 8)1/8-inch TRS and Stereo RCA connectors as per Department Incharge 748 Supplying of Lapel Clip-on Microphone for DSLRs Camcorders Video Cameras and Iphone Smart Phone :- 1)Omni directional lavalier microphone, designed for Smartphones, DSLR, Camcorders, Audio recorders PC etc, perfect for video use. 2) With Omni pickup pattern, for full 360A coverage, 3) minimum 6-meter )20(cable with 3.5mm 4-pole gold plug for smarty phone connection as per Department Incharge 749 Supplying of Micophone Stand:- Steel stands for hand held microphones in studio with a base supporting system as per Department Incharge 750 Supplying of MP3 Digital Voice IC Recorder LCD :- 1)Digital Voice IC Recorder 2)LCD Screen 3) 23hrs life with 4GB Memory as per Department Incharge
Contract Date: Jun 17, 2026 Contract Value : 78.07 Crore
Government Departments No of Bidders 9
17.
Housing Urban and Rular Development #10156644 Price Bid
Tender For Renovation Of Temple Pond At Kovur; 1 Civil Work 2 Earth work open well excavation complying with relevant clauses of T.N.D.S.S. Well sinking and with lead upto 10 metre in Hard stiff clay, stiff black coton soil, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil -First depth of 2 metre 3 Removal of Excavated Excess Earth away from the site to 2K.M including loading and transportation charges etc, complete as per standard specification. 4 Cleaning The julifora jungle with uprooting 5 Earthwork excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wetsand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive and levelling the site etc., complete - Open Earthwork Excxavation 6 Supply and filling in foundation with Filling M-Sand in layer of 15cm thick well water rammed to consolidation including cost and conveyance of Sand to site including labour charges etc., complete as per standard specification 7 Plain cement Concrete 1:4:8 using 40mm size ISS HBG metal including cost and conveyance of all materials to site and labour charges and all incidential charges such as water providing etc., comlete as per standard specification 8 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam 9 Up to 90cm 10 Up to 180cm 11 Column 12 Slab 13 Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm size ISS HBG, including cost and conveyance of all materials to site and including for the mixing, laying and labour charges,complete as per standard specifications 14 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - 15 Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. 16 Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. 17 Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications 18 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 19 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 20 Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. 21 Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per clause 406 of MORTH specifications 22 Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of63mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. 23 Supplying and fixing in position SFRC.Manhole covers of 90 X 90cm in size of best approved quality and as per standard specifications etc.,complete. 24 Rough stone Dry Packing for Aprons and revetments using rough stones and the cost shall inclusive all materials and labour charges etc complete 25 FRP DIE MAKING Project Name: PILLAR & TOP DESIGN Material: FRP 26 FRP PART Project Name: PILLAR - 24sq.ft (240cm x 23cm) Material: FRP 27 FRP PART Project Name: TOP DESIGN - 6 Sq.ft (50cm x 50cm) Material: FRP 28 Garden Bench model-kff-2001 4 feet,2 seater with enamel painted cast iron arm handle and seating and back with 9 wpc section size (75mmx20mmx1200) 29 Providing 3.5feet Penguin Fiber dustbin in various places on walking track with all necessary accessories etc., completye as directed by the departmental officers 30 Supply and Fixing of RCC pipe0.60cm dia including material nd labour charges etc., complete with standard specification. 31 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 32 ELECTRICAL WORKS 33 Supply, Installation, Testing & Commissioning of Kesslec 40W Decorative Classic LED street lantern with a total Ht of the Pole shall be 4.0M, BIS certified withaluminairebodymadeofcastandspun aluminium,permanentlysealedopticalblock (IP66) with heat sink and polycarbonate protector (IK10) fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, controlgearcompartment(IP44)accessedby loosening one screw for tool free opening and closing. Highly efficient temperature resistant lenses for asymmetric light distribution forprovidingexcellent photometrytooptimallycatertothe desired applications. Suitablefora galvanised painted oval shaped mounting bracket for Post Top version. Overallsystemefficiencyof120lm/Wat correlatedcolourtemperature(CCT)of3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. ElectricalClassI,ratedvoltage240Vac,Power Factor≥0.95,withBIScertifiedpotteddriver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV (in both Common & Differential Modes). 34 The Decorative Column shall meet the following details: 4.0 metre height above the ground level made out of GI, tubular pole ‘T’ washed and primered. (ASTM A123, with minimum average GI coating of 65μm.), having two sections, bottom section of minimum 1000mm (L) x 140mm dia and the top section with minimum of 3000mm (L) x 76mm dia, in built junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out. Design comply EN40 standard and basic wind speed 169kmph. The Embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column. The Pole Base plate should be with 250x250x12 mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening.The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240. Poles using pre galvanised tube or hot dip galvanised through double dip process is not acceptable. 35 The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. Complete pole & shall be treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint (marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron).The pole shall have inbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of composite’ construction designed to ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. CAT REF: 40WW WW LED & CHATSWORTH Pole 4.0M GI PU painted with Base Plate. 36 Supply and Laying of Cable 37 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 38 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 39 Brass Compression Gland 40 Supply and fixing of brass cable gland for 4x16sq.mm. PVC armoured LTUG cable with earth connection. 41 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 42 END Termination with Al Lugs 43 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 44 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 45 Fabrication, supplying, installation and commissioning of outdoor double door cubical feeder pillar of suitable size with locking arrangement in front & back with rain cap cover suitable for 3 phase, 4 wire 415 volt 50Hz dust and vermin proof made with CRCA sheet duly compartmentalized. and 4 strips 100A capacity aluminium bus bar with colour coded heat shrinkable insulation PVC sleeve with i/c providing & fixing following switch gears & accessories therein complete with connections, inter connections with suitable size of aluminium strips / bars/ copper wires i/c powder coated with grey paint after 7 tank treatment, painting, two no’s earthing studs, suitable base frame fabricated with 50mmx 50mm x 5mm angle iron grouted in cement concrete so as to keep the feeder pillar 200mm above the ground level, cable allay and detachable gland plates at bottom, rubber gasket for doors with locking arrangement etc. complete as required.a) 63 Amp, 25kA, FP MCCB with spreader links, door interlock assembly & operating handle - 1 No (Incomer) b) 16Amps, DP 10kA DIN rail mounted MCB 46 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry 47 Supply and Run of 1 of No.8 SWG copper wire for earth connection 48 Supply and fixing of TNEB meter board suitable for 32A Three phase service connection with 3 numbers 32A fuse unit (500V) 32A neutral link and earth link (1 x 1/8 copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1 thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection 49 CCTV CAMERA 50 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 6T Hard Disk Drive 4 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency,Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony ) 51 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic) 52 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 53 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 54 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pairvi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 55 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point(Point to Point) Crimping, Testing and arrangement charges. 56 Supply and fixing of 24 Port 2SFP with Module, PoE Giga Range Lan Switch.• 24Ports10/100/1000 Base-TPoE+ 4 x Combo Gigabit UTP or Gigabit SFP slots• Support IEEE 802.3af (PoE) and 802.3at (PoE+) Standard• Equipped with IEEE 802.3az Energy Efficient Ethernet (EEE) Complaint• SupportIEEE 802.1Q VLAN traffic segregation• Access Control List (ACL) feature to enhances network security• Auto Surveillance VLAN for easy integration with IP-based surveillance systems• Loopback detection (LBD) and broadcast storm control to avoid network downtime• Quality of Service (QOS) and bandwidth control to ensure smooth operation• Support Web-based GUI, Smart Console , Network Assistance Utility• Cable diagnostics function to help troubleshooting wiring problem including Optical Fiber Cable connecting network accessories. (Make: DLINK, NETGEAR,TPLINK) 57 Supply and Fixing of Rack with Accessories -Higher end 4 U Rack with LNS unit and fan extra for the above rack. 58 Supply and Instalatin for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up. 59 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 60 GREENERIES 61 Supplying and Planting of ALSTONIAsapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 62 Supplying and Planting of Pungam treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 63 Planting of Hibiscus hawai foliage shrubvariety of height 30-45 cm in polythenebag of dia 20 cm including loading andunloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 64 Supplying and Planting of Peltophorumtree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurina196 PD-895pole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 65 Supplying and Planting of Plumeria treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 66 Supplying and Planting of Poovarasutree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 67 Supplying and Planting of Albizia treesapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge 68 Supplying and Planting of Saraca indicatree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 69 Supplying and Planting of Shenbagamtree sapling of height 240 - 270 cm inpolythene bag of dia 30cm includingsupporting stack of 5 cm dia casurinapole of 10 feet height, including loadingand unloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 70 Supplying and Planting of Syzygiumcumini tree sapling of height 240 - 270cm in polythene bag of dia 30cmincluding supporting stack of 5 cm diacasurina pole of 10 feet height, includingloading and unloading charges,transportation, stacking of saplings atsite, earth work excavation of requiredsize, planting of sapling, refilling ofexcavated earth etc as directed by thesite in-charge. 71 Planting of Aloe vera Herbal plantvariety of height 20-25 cm in polythenebag of dia 20 cm including loading andunloading charges, transportation,stacking of saplings at site, earth workexcavation of required size, planting ofsapling, refilling of excavated earth etc asdirected by the site in-charge. 72 STP ARRANGEMENTS 73 STP Arrangements 74 Air Injector 75 Water Fountain
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
18.
Educational and Research Institute #10088358 Price Bid
Supply Of Books , Library Books , Machine Design, T. V. Sundararajamoorthy & N. Shanmuga ,Anuradha Publications, Kumbakonam. , Revised Edition June-2003 , Industrial Motor Control., Stephen Herman ,Cengage Learning , 6Th Edition , Electrical Technology, Edward Hughes ,Addision– Wesley International Student Edition , Latest Edition , Mysql, Paul Dubois ,Addison Wesley , 4Th Edition , No Sql Distilled, Pramod J. Sadalage Martin Fowler ,Addison Wesley , 1St Edition Or Latest Reprint , American Society Of Metals – Hand Book – Volume 4 ( Forming), American Society Of Metals,American Society Of Metals , Latest Edition , Programmable Controller Theory And Implementation, L.A.Bryan E.A.Bryan ,An Industrial Text Company Publication , Latest Edition , Biomedical Instrumentation, M. Arumugam ,Anuradha Publications, Chennai , Latest Edition , Android Apps For Absolute Beginners, Jackson ,Apress , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Arasan Ganesan Institute Of Technology , 1993 , Home Refrigeration And Air Conditioning, Audels, Theo. ,Audel & Co. Publisher, New York. - 1998 , 199 Edn.49 , Remote Sensing And Geographical Information System, M.Anji Reddy ,B.S Publications , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , 1997 , Exploring Programmable Logic Controller With Applications, Pradeep Kumar Srivastava ,Bpb Publication , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , Latest Edition , Advanced Mobile Repairing, Pandit Sanjib ,Bpb Publication , First Edition 2010 , Modern Vcd Video Cd Player Introduction, Servicing And Troubleshooting, Manohar Lotia & Pradeep Nair ,Bpb Publication , Latest Edition , Explosing Programmable Logic Controllers With Application., Pradeep Kumar Srivastava. ,Bpb Publication , Latest Edition , Let Us C, Yeswanth Kanetkar ,Bpb Publication , 16Th Edition , Programmable Logic Controller, Pradeep Kumar & Srivashtava ,Bpb Publication , Latest Edition , Modern Computer Hardware Course, Manahar Lotai, Pradeep Niar, Payal Lotia ,Bpb Publication , Second Revised Edition 2011 , Inside Autocad, D. Raker And H. Rice,Bpb Publication , Latest Edition , Text Book Of Environmental Science And Technology, M.Anji Reddi ,Bs Publications , Latest Edition , Book 1 - General Aspect Of Energy Management And Energy Audit,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , Book 3 - Energy Efficiency In Electrical Utilities,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , National Building Code Of India – 2005,,,Bureau Of Indian Standards, New Delhi , Latest Edition , Total Quality Management, Oakiand.J.S.,Butterworth Heinemann Ltd. Oxford , 1989 , The Art Of Electronics, Paul Horowitz ,Cambridge University , 2Nd Edition Press , Performance And Design Of Ac Machine, M.G.Say ,Cbs Publisher & Distributor , Latest Edition , A Text Book Of Soil Mechanics, Dr S B Sehgal ,Cbs Publisher & Distributors , Latest Edition , Building Repair And Maintenance Management, P.S.Gahlot ,Cbs Publisher & Distributors (P) Ltd , Latest Edition , Learning Material Development Project – Nitttr,,Cd Programme On Gps And Gis. , Latest Edition , Introduction To Programmable Logic Controllers, Gary Dunning ,Cengagelearning India Pvt Ltd , Latest Edition , Building Materials, S.C.Rangwala ,Charotar Publishing House , 1982 , Building Construction, S.C.Rangwala ,Charotar Publishing House , Latest Edition , Mechanics Of Structures (Vol Ii), S.B. Junnarkar ,Charotar Publishing House , 22Nd Edition , Highway Engineering, Rangwala ,Charotar Publishing House , 2010 , Railway Engineering, Rangwala ,Charotar Publishing House , 2010 , Bridge Engineering, Rangwala ,Charotar Publishing House , 2009 , Estimating & Costing, Rangawala ,Charotar Publishing House , Latest Edition , Construction Of Structures And Management Of Works, Rangwala.S.C ,Charotar Publishing House , Latest Edition , Machine Design, Pandya & Shah ,Charotar Publishing House , 1995 , Principle Of Geographical Information Systems For Land Resources Assessment, Burrough P.A. (2000) ,Clarendon Press, Oxford. , Latest Edition , Technician’S Guide To Programmable Logic Controllers, Richard A. Cox ,Delmer , Sixth Edition 2011 , Principles Of The Manufacturing Of Composite Materials , Suong V Hoa, ,Des Tech Publication. Inc , Latest Edition , Strength Of Materials, S.Ramamirtham ,Dhanpat Rai , 2003 , A Course In Electrical And Electronics Measurements And Instrumentation., A.K. Sawhney Puneet Sawhney ,Dhanpat Rai , Latest Edition , Estimating & Costing, L.N.Dutta ,Dhanpat Rai , Latest Edition , Thermal Engineering., B.K. Sarkar. ,Dhanpat Rai , 3Rd Edition , Internal Combustion Engines, M.L.Mathur & R.P.Sharma ,Dhanpat Rai , Latest Edition , Mechanical Draughtsmanship,G.L. Tamta, Dhanpat Rai ,Dhanpat Rai , Latest Edition , Engineering Drawing, D.N. Ghose ,Dhanpat Rai , Latest Edition , A Course In Electrical Power, Soni & Gupta ,Dhanpat Rai , Latest Edition , Hydraulics,Fluid Mechanics And Hydraulics Machines, S. Ramamirtham ,Dhanpat Rai , Latest Edition , Modern Electric Traction, H Partab ,Dhanpat Rai , Latest Edition , Mechanical Measurements, A.K.Sawhney-Dhanpat Rai & Sons ,Dhanpat Rai , Latest Edition , Electronic Measurements And Instrumentation, Sanjay Talbar & Akhilesh Upadhyaya ,Dhanpat Rai , 2004 , Electrical And Electronic Measurements And Instrumentation, A.K.Sawheney ,Dhanpat Rai , 1993 , A Coursein Electricalpower, Soni, Gupta ,Dhanpat Rai , Latest Edition , Strength Of Materials, S. Ramamrutham ,Dhanpat Rai , 15 Edn 2004 , Course In Electrical Machine Design, A.K.Sawhney ,Dhanpat Rai , Latest Edition , Electrical Technology, B.L.Theraja ,Division Of Nirja Constructions And Dev Co.(P) Ltd , 1994 , Design Data Book, Psg College Of Technology ,Dpv Printers, Coimbatore , Latest Edition , Suftware Testing Concepts And Tools, Nageshwara Rao Pusulri ,Dreamteach , First Edition , Automotive Mechanics, Joseph Heitner ,East West Press (P) Ltd, New Delhi , Latest Edition , Renewableenergy Sources , Twidell, J.W. And Weir, ,Efn Spon Ltd , Latest Edition , Vehicle And Engine Technology, Heinz Heisler ,Elbs , Latest Edition , Programmable Logic Controller, W. Bolton ,Elsevier India Pvt Ltd , Iv Edition , Principles And Practice Of Town And Country Planning, Lewis B. Keeble ,Estates Gazette, University Of Michigan , 2010 , A Text Book On Building Services, R.Udyakumar ,Eswar Press, Chennai , Latest Edition , Fluid Mechanics, K.L.Kumar ,Eurasia Publshing House - New Delhi , Latest Edition , A Text Book Of Machine Design., R.S. Khurmi & J.K.Gupta ,Eurosia Publishing House - New Delhi ,Edn. 18 , Mechanical Measureme Control, R.V. Jalgaonk ,Everes T Publishing House, Pune , Latest Edition , The Cell Phone Handbook, P.J. Stetz And Penelope Stetz ,Findtech Ltd , Second Edition , Pc Repair And Maintenance, Joel Rosenthal ,Fire Wall Media, New Delhi , First Edition 2007 Reprint :2012 , Software Engineering, Bharat Bhusan Agarwal, Sumit Prakash Tayal ,Fire Wall Media, New Delhi , Second Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , Multimedia Technology & Applications,, David Hillman ,Galgotia Publications Pvt Ltd. , Latest Reprint , Repair And Seismic Strengthening Of Buildings - Guidelines, Is:13935 - 2002,,Guidelines, Is:13935 , 2002 , Automotive Mechanics, William H.Crouse And Donald .L. Anglin ,Hill Publishing Company Ltd, New Delhi , Latest Edition , Die Design Fundamentals, Paquin.J.R,,Industrial Press Inc , Latest Edition , Digital And Analog Communication System, B.P.Lathi .Zhi Ding ,International Oxford University Press , 4Th Edition , Mysql Bible, Steve Suehring ,John Wiley & Sons , 2002, Latest Reprint , Modern Production / Operations Management, E.S. Buffa And R.K. Sarin ,John Wiley & Sons , Latest Edition , Remote Sensing And Image Interpretation, Lillesand, T.M. & Kiefer R.W. (1998) ,John Wiley & Sons , Latest Edition , Ground Water Hydrology, David Keith Todd ,John Wiley & Sons , Latest Edition , Digital Communications, Simon Haykin ,John Wiley India Edition , Latest Edition , Cad/Cam, Mikell P.Groover ,Jr.Prentice Hall Of India Pvt., Ltd. , Latest Edition , A Course In Electrical Power, J.B. Gupta ,Kaison Publishing House , Reprint 2004 , Civil Estimating, Costing And Valuation,,Kalson Publishing House , Latest Edition , Machine Drawing, P.S. Gill ,Katsan Publishing House , Latest Edition , Analysis Of Structures – Vol 1, Vazirani & Ratwani ,Khanna Publishers , Latest Edition , Quantity Surveying & Valuation, N.A.Shaw ,Khanna Publishers , Latest Edition , Water Supply And Sanitary Engineering, S.K.Garg ,Khanna Publishers , Latest Edition , Hydrology And Water Resources Engineering, Santhosh Kumar Gar ,Khanna Publishers , Latest Edition , Fluid Mechanics, Prof. S. Nagarathinam - ,Khanna Publishers , Latest Edition , Workshop Technology ,Raghuwanshi,Khanna Publishers , Latest Edition , Production Technology,Nai Sarak ,Khanna Publishers ,Edn. Xii , Thermal Engineering, P.Lballaney ,Khanna Publishers , 24Th Edition , Production Technology, Jain & Gupta ,Khanna Publishers , Latest Edition , Automobile Engineering, G.B.S.Narang ,Khanna Publishers , Latest Edition , Thermal Engineering, P.L Ballaney,Khanna Publishers , 24Th Edition , Applied Thermodynamics, Domkundwar And C.Pkothandaraman ,Khanna Publishers ,2Nd Edition , Non Conventional Energy Sources, G.D. Rai,Khanna Publishers , 1999 , Industrial Engineering And Management, O.P. Khanna ,Khanna Publishers , Latest Edition , Refrigeration And Air Conditioning, P.L . Ballaney ,Khanna Publishers , Latest Edition , Electric Circuit Theory, Dr.M.Arumugam Dr.N.Premkumaran ,Khanna Publishers , Latest Edition , Electrical Power, S.L Uppal ,Khanna Publishers , Latest Edition , Electrical Wiring, Estimating And Costing, Dr.S.L.Uppal G.C. Garg ,Khanna Publishers , Sixth- 2011 , Electric Circuit Theory, M. Arumugam, N. Premkumaran ,Khanna Publishers , 1997 , Power Electronics, P.S.Bimbhra, ,Khanna Publishers , 5Th Edition 1994 , Integrated Circuits, K.R. Botkar ,Khanna Publishers , Latest Edition , Satellite Communication, D.C. Agarwal ,Khanna Publishers , Third Edition , A Monograph On Electronic S Design Principles,, N.C.Goyel, R.K.Khetan, ,Khanna Publishers , Second Edition , Operating Systems, Ekta Walia ,Khanna Publishers , 2Nd Edition , Data Structures, Rs Salaria ,Khanna Publishers , 2016 , Electric Power, Sl Uppal ,Khanna Publishers , Latest Edition , Testing, Commissioning, Operation And Maintenance Of Electrical Equipments, S.Rao ,Khanna Publishers , Sixth Edition, 2010 , Electrical Estimation And Costing, Surjit Singh ,Khanna Publishers , Latest Edition , Power Electronics, Dr.P.S.Bimbhra ,Khanna Publishers , Fourth Edition, 2011. , Mechanical & Indtrial Measuments, R.K.Jain ,Khanna Publishers , Latest Edition , Construction Management, Sanga Reddy. S ,Kumaran Publications, Coimbatore , Latest Edition , Fluid Mechanics, R.K. Bansal ,Lakshmi Publications , Latest Edition , Total Quality Management,, V.Jayakumar ,Lakshmi Publications. , (Reprint 2005) , Thermal Enggi., R.K . Rajput,Laxmi Publications Pvt Ltd , 8Th Edition , Fluid Mechanics And Hydraulic Machines, R. K. Bansal ,Laxmi Publications Pvt Ltd , Latest Edition , Engineering Mechanics, R K Bansa ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Dr. B.C. Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Ashokkumar Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume I, Punmia.B.C. Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , 2011 , Theory Of Structures, B.C. Punmia, Ashok Jain & Arun Jain ,Laxmi Publications Pvt.Ltd. , 9Th Edition , Surveying Volume I, Punmia.B.C, Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume Ii & Iii, Punmia.B.C, Ashok Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Limit State Design Of Reinforced Concrete, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , R C C Designs, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Environmental Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Waste Water Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Soil Mechanics And Foundation Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Project Planning And Control With Pert And Cpm, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Buildingconstruction, Dr.B.C.Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Strength Of Materials, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 3Rd Edition, 2010. , Engineering Mechanics, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 2Nd Edition, 2007 , Thermal Engg, R.K .Rajput ,Laxmi Publications Pvt Ltd , 8Th Edition , Industrial Robotics – Technology, Programming And Applications, P.Groover ,Mc Graw Hill , 2001 , Mobile Cellular Communications, W.C.Y. Lee ,Mc Graw Hill , Second Edition , Electronic Principles And Applications, Charles.A.Schuler ,Mc Graw Hill , 3Rd Edition, 1989 , Geotechnical Earthquake Engineering Hand Book, Robert W.Day ,Mc Graw Hill , Latest Edition , Measurement Systems Application And Design, Ernest O. Doebelin ,Mc Graw Hill , 2004 , Transducers And Instrumentation, D.V.S.Murty ,Mc Graw Hill , 2004 , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , Latest Edition , Digital Integrated Electronics, Taub & Schlling ,Mc Graw Hill , Latest Edition , Optical Fibre Communication, Gerd Keiser ,Mc Graw Hill , Third Edition , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , 1994 , Computer Control Of Manufacturing Systems, Yoram Koren ,Mc Graw Hill , Latest Edition , Engineering Economics And Management, T.R. Banga & S.C. Sharma ,Mc Graw Hill , Editiion 2 – 2001 , Database System Concepts, Silberschatz A. And Korth H ,Mcgraw Hill Education (India) Pvt Limited , 6Th Edition , A Global Perspective, Heinz Weihrich, Harold Koontz ,Mcgraw Hill International Edition ,10Th Edition , Hessentials Of Management’, Herald Koontz And Heinz Weihrich ,Mcgraw Hill Publishing Company , Latest Edition , Power Electronics, Md Singh, Kb Dhanchandaniata ,Mcgraw Hill Publishing Company , Seventeenth Reprint 2005 , Operating Systems, A Concept-Based Approach, Dhananjay M. Dhamdhere ,Mcgraw Hill, Indian Edition , 3Rd Edition , Elements Of Photogrammetry, Wolf Paul (1998) ,Mcgraw Hill, New Delhi , Latest Edition , Manufacturing Process, Begeman . ,Mcgraw Hill, New Delhi1981. , 5Th Edition , Introduction To Environmental Engineering, Mackenzie, L. Davis And A. David, Cornwell. ,Mcgrawhill , Latest Edition , Environmental Engineering, Peary, Rowe And Tchobanoglous ,Mcgrawhill , Latest Edition , Fundamentals Of Digital Logic With Vhdl Design, Stephen Brown And Vranesic ,Mcgrawhill , Latest Edition , Programmable Logic Handbook: Pld, Cpld, And Fpga, Ashok K.Sharma ,Mcgraw-Hill , Latest Edition , Javascript: The Complete Reference, Powell, Thomas ,Mc-Grawhill , 3Rd Edition , Html & Css: The Complete Reference, Thomas Powell ,Mc-Grawhill , 5Th Edition , Jsp: The Complete Reference, Phil Hanna ,Mc-Grawhill , 2Nd Edition , Robotics For Engineers, Yoram Koren ,Mcgraw-Hill Book Co., , 1992 , “Basic Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Advanced Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Hand Book Of Die Design, Ivana Suchy ,Mcgraw-Hill Book Company , Latest Edition , Tool Engineers Hand Book, Astme ,Mcgraw-Hill Book Company , Latest Edition , Robotics Control, Sensing, Vision And Intelligence, Fu.K.S.Gonzalz.R.C., And Lee C.S.G ,Mcgraw-Hill Book Company , 1987 , Audio And Video System – Principles, Maintenance And Troubleshooting , R.Gupta. ,Mcgraw-Hill Book Company ,Second Edition , Computer Organization, V.Carl Hamacher, Zvonko G.Vransic, Safgat G.Zaky ,Mcgraw-Hill Book Company , 5Th Edition , Elements Of Workshop Technology Volume I & Ii, Hajra Chowdry & Bhattacharaya,Media Promoters & Publishers , Latest Edition , Operation And Maintenance Of Electrical Equipment – Volume I & Ii, B.V.S.Rao ,Media Promoters & Publishers , 1St Edition, 1St Reprint 2011 , Elements Of Workshop Technology- Vol. I & Ii,Hajra Choudry & Battacharya ,Media Promoters & Publishers , Latest Edition , Hydraulic Machines, Jagadishlal, ,Metropolitan Book Company New Delhi , Latest Edition , Fluid Mechanics And Hydraulic Machines, Dr. Jagadish Lal ,Metropolitan Book Company New Delhi , Latest Edition , Mechanical Measurements &Control, D.S.Kumar ,Metropolitan Book Company New Delhi , Latest Edition , Introducing Microsoft .Net, David S.Platt ,Microsoft Press , 3Rd Edition , Computer Organization And Design, David A. Patterson And John L. Hennessey ,Morgan Kauffman / Elsevier , 5Th Edition , Complete Knowledge In C, Sukhendu Dey, Debobrata Dutta ,Narosa Publishing House, New Delhi , Reprint 2013 Or Latest Reprint , Software Testing, K.Mustafa And R.A.Khan ,Narosa Publishing House, New Delhi , Reprint 2009 , Software Quality, R.A. Khan, K.Mustafa And Si ,Narosa Publishing House, New Delhi , Reprint 2008 , Building Materials, S.K.Dugga ,New Age International (P) Ltd , 2003 , Reinforced Concrete Design, N Krishnaraju ,New Age International (P) Ltd , Latest Edition , Design Of R C C And Structural Elements ( Rcc Vol I), S S Bhavikatti, ,New Age International (P) Ltd , Latest Edition , G I S Basics, Shahab Fazal ,New Age International (P) Ltd , Latest Edition , Irrigation And Water Resources Engineering, G.L.Asawa ,New Age International (P) Ltd , Latest Edition , Basic Geotechnical Earthquake Engineering,,New Age International (P) Ltd , Latest Edition , Maintenance Of Buildings, A C Panchdhar ,New Age International (P) Ltd , Latest Edition , Engineeringdrawing And Graphics + Autoca, K.Venugopal, ,New Age International (P) Ltd , Latest Edition , Control Of Machines, S.K Bhattacharya ,New Age International (P) Ltd , Second Edition- Reprint 2010 , Quality Manageme, Narayana.V And Sreeniva N.S ,New Age International (P) Ltd , 1996 , Cad/Cam/Cim, R.Radhakrishnan, S.Subramanian ,New Age International (P) Ltd , Latest Edition , Electrical Power System, Clwadhawa ,New Age International (P) Ltd , Fourth Edition, 2009 , Hvdc Power Transmission System & Technology, Kr. Padiyar ,New Age International (P) Ltd , Reprint 2005 , Digital Protection – Protective Relaying From Electromechanical To Microprocessor, Lp Singh ,New Age International (P) Ltd , Second Edition 1997 , Electrical Design Estimating And Costing, K.B.Raina& S.K.Battacharya ,New Age International (P) Ltd , Reprint - 2011 , Control Of Electrical Machines., S.K. Bhattacharya ,New Age International (P) Ltd , Latest Edition , Power Electronics, Mohammed H.Rashid ,New Age International (P) Ltd , Third Edition,2004 , Programming In C, D.Ravichandran ,New Age International (P) Ltd , 1St Edition 1996, Latest Reprint , Linear Integrated Circuits, D.Roychoudhury & Shail.B. Jain ,New Age International (P) Ltd , 2Nd Edition, 2004. , Modern Television Practice– Transmission, Reception, Applications, R.R.Gulati,New Age International (P) Ltd , 5Th Edition , Monochrome & Color Tv , R.R.Gulati ,New Age International (P) Ltd , Latest Edition , Computer Fundamentals Architecture And Organization, B. Ram ,New Age International (P) Ltd , 5Th Edition , Principles Of Data Structures Using C And C++, Vinu V.Das ,New Age International (P) Ltd , Latest Reprint , Practical Scada For Industry, David Bailey Edwin Wright ,Newness , Latest Edition , Programmable Logic Controllers, W. Bolton ,Newness , Latest Edition , Practical C Programming, Steve Oualline ,O’Reilly , 3Rd Edition , Programming Php, Rasmus Lerdorf And Kevin Tatroe ,O’Reilly Publications , 3Rd Edition , Java, A Beginners Guide, Herbert Schildt ,Oracle Press , 6Th Edition , Pc Hardware In A Nutshell, Robert Bruce Thompson. ,Oreilly Media , Third Indian Reprint 2008. , Principles Of Electrical Machine Design, S.K.Sen ,Oxford & Ibh , Latest Edition , Principles Of Gis For Land Resources Assessment, Burrough P A ,Oxford Publication , Latest Edition , Programming In C, Reema Thereja ,Oxford University Press , 2Nd Edition , Digital Electronics, G.K.Kharate ,Oxford University Press , 2010 , Software Engineering Concepts And Application, Subhasjit Dattun ,Oxford University Press , 2010 , Software Engineering Fundamentals, Ali Behforooz And Fredick J Hudson ,Oxford University Press , 2005 , Reinforced Cement Concrete, Mallick And Rangasamy ,Oxford & Ibh , Latest Edition , Digital Communications Fundamentals And Applications, Bernard Sklar & Pabitra Kumar Ray ,Pearson Education , Latest Edition , Advanced Surveying, Sathesh Gopi, R.Sathikumar & N.Madhu ,Pearson Education , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C , Mazidi,Mazidi And D.Mackinlay,,Pearson Education , Latest Edition , Programmable Logic Controllers – Programming Methods And Applications, John R Hackworth And Fredrick D.Hackworth ,Pearson Education , Latest Edition , Principles Of Wireless Networks– A Unified Approach, Kaveh Pahlavan And Prashant Krishnamoorthy ,Pearson Education , 2002 , Electronic Communications Systems - Fundamentals Through Advanced, Wayne Tomasi ,Pearson Education , Fifth Edition , Digital Design, M.Morris Mano Michael D Ciletti ,Pearson Education , Latest Edition , 8051 Microcontrollers, Mazidi And D.Mackinlay ,Pearson Education , Latest Edition , Principles Of Wireless Networks – A Unified Approach, Kaveh Pahlavan And Prashant Krishnamurty ,Pearson Education , Latest Edition , Wireless Communications Principles And Practice, Theodore S. Rappaport ,Pearson Education , Latest Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Second Edition , Mobile Cellular Communication, Gottapu Sasibhushana Rao ,Pearson Education , Latest Edition , Operating System, Internal And Design Principles, William Stallings ,Pearson Education , 9Th Edition , Operating Systems, Deitel And Deitel ,Pearson Education , 3Rd Edition , Computer Organization And Architecture Designing For Performance, William Stallings ,Pearson Education , 10Thedition , Network Security Essentials, William Stallings ,Pearson Education , 5Th Edition , Cryptography And Network Security, William Stallings ,Pearson Education , 6Th Edition , Computer Networks, Andrew S.Tanenbaum ,Pearson Education , 5Th Edition , Web Development And Design Foundations With Html5, Terry Felke-Morris ,Pearson Education , 8Th Edition , Software Engineering, Ian Sommerville ,Pearson Education , Sixth Edition , Software Testing Principles And Practices, Srnivasan Desikan, Gopalswamy Ramesh ,Pearson Education , First Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Latest Edition , Fundamental Of Multimedia, Ze- Nian Li And M.S.Drew. ,Pearson Education , 2Nd Edition , Multimedia Computing, Communication And Applications, Ralf Steinmetz And Klara Nahrstedt ,Pearson Education , Latest Reprint , Multimedia Systems, John F. Koegel Buford ,Pearson Education , Latest Reprint , Total Quality Management, Date H.Besterfiled ,Pearson Education Asia. , Latest Edition , Automation, Production Systems, And Computer-Integrated Manufacturing, Mikell P. Groover ,Pearson Education Asia. , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C, Mazidi,Mazidi And D.Mackinlay ,Pearson Education Low Price Edition. , Latest Edition , Design Of Steel Structures, K.S.Sai Ram ,Pearson-Porling Kindersley Pvt Ltd , Latest Edition , 8051 Microcontroller, Kenneth Ayala ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Plc And Industrial Automation An Introduction, Madhuchhanda Mitraand Samarjit Sen Gupta ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Industrial Energy Conservation-, D. A. Ray- ,Pergaman Press , Latest Edition , Electronics Devices And Circuit Theory, Boyestad & Nashelsky ,Phi , Latest Edition , Electronic Devices & Circuits An Introduction, Allen Mottershed,Phi , Latest Edition , Computer Graphics Multimedia And Animation,, Malay K. Pakhira ,Phi , 2Nd Edition , Principles Of Digital Electronics, K.Meena ,Phi , 2011 , Operational Amplifiers And Linear Integrated Circuits, Robert F. Coughlin Frederick F. Driscoll ,Phi , 1992 , Op. Amp & Linear Integrated Circuits, Ramakant. A. Gayakwad ,Phi , 1992 , Digital Electronics- An Introduction To Theory And Practice, William H.Gothmann ,Phi , 1998 , Transducers And Instrumentation, Dvs Murty ,Phi , 2009 , Measurement And Instrumentation, Arun. K ,Phi , 2010 , Sensor And Transducers, D. Patranabis ,Phi , 2011 , Elements Of Engineering Mechanics, Sanchayan Mukherjee ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass, ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Limit State Design Of Reinforced Concrete, P C Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, .M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Principles Of Environmental Science And Engineering,, P.Venugopala Rao ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Irrigation And Water Power Engineering, Madan Mohan Das&Mimi Das Saikia ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Buildingconstruction, P.C.Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Energy Engineering And Management, Amlan Chakrabarti ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Power Electronics, M.S.Jamil Asghar ,Phi Learning Pvt. Ltd., New Delhi. , Eastern Economy Edition, 2010 , Principles Of Digital Electronics, K.Meena ,Phi Learning Pvt. Ltd., New Delhi. , 2009 , Operating System, Principles & Design, Pabitra Pal Chaudhuri ,Phi Learning Pvt. Ltd., New Delhi. , 1St Edition , Computer Organization & Architecture, Rajaraman ,Phi Learning Pvt. Ltd., New Delhi. , Latest Reprint , Fundamentals Of Software Engineering, Rajib Mall ,Phi Learning Pvt. Ltd., New Delhi. , 28Th Printing – August 2011 , A Textbook On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Electronics Devices And Circuit Theory , Boyestad & Nashelsky ,Phi Publication, New Delhi , 2009 , Electronicsdevices And Circuits, Allen Mottershed ,Phi Publication, New Delhi , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D.Helfrick And Willam David Cooper ,Phi Publication, New Delhi , 1996 , A Text Book On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Power Electronics, M.H.Rashid ,Phi Publication, New Delhi , 3Rd Edition-2005 , Industrial Electronics And Control, Biswanath Paul ,Phi Publication, New Delhi , 2Nd Edition -2010 , Programmable Logic Controllers, Frank D.Petruzela ,Phi Publication, New Delhi , 2Nd Edition- 1998 , Programmable Logic Controllers Principles And Applications, John W. Webb. Ronald A. Reis ,Phi Publication, New Delhi , Latest Edition , Networks Lines And Fields, John D.Ryder ,Phi Publication, New Delhi , Latest Edition , Electronic Communication, Dennis Roddy And John Colen ,Phi Publication, New Delhi , Latest Edition , Principles Of Digital Electronics, K.Meena ,Phi Publication, New Delhi , Latest Edition , Digital Electronics, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Digital Electronics – An Introduction To Theory And Practice, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Ramakant A Gayakwad ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Robert F.Coughlin And Frederick F.Driscoll ,Phi Publication, New Delhi , Latest Edition , Microcontrollers, Principles And Applications, Ajit Pal ,Phi Publication, New Delhi , Latest Edition , Vhdl Primer, Bhasker J ,Phi Publication, New Delhi , Latest Edition , Digital Electronics With Pld Integration, Nigel P. Cook ,Phi Publication, New Delhi , Latest Edition , Digital Logic Simulation And Cpld Programming With Vhdl, Steve Waterman ,Phi Publication, New Delhi , Latest Edition , Data And Computer Communications, William Stallings ,Phi Publication, New Delhi , Latest Edition , Computer Networks , Andrew S.Tanenbaum ,Phi Publication, New Delhi , Latest Edition , Wireless Digital Communications, Kamilo Feher ,Phi Publication, New Delhi , Latest Edition , Wireless Communications And Networks, William Stallings ,Phi Publication, New Delhi , Latest Edition , Irrigation Water Management, Dilip Kumar Majumdar ,Phi Publication, New Delhi , Latest Edition , Multimedia Systems Design., Prabhat K.Andleigh, Kiran Thakra ,Phi Publication, New Delhi , Latest Edition , Performance And Design Of Ac Machines, M.G.Say ,Pitman Publishing Ltd , Latest Edition , Principles Of Management, M.Govindarajan And S.Natarajan ,Prentice-Hall Of India (P) Ltd , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D. Helfrick William David Cooper ,Prentice-Hall Of India (P) Ltd , Latest Edition , Building Materials, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Building Constructions, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Geographic Information Systems, Lo & Yeung (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Geographic Information Systems & Environmental Modelling, Clarke Parks & Crane (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Foundation Design, Wayne C.Teng ,Prentice-Hall Of India (P) Ltd , Latest Edition , Operations Research, H.A.Taha ,Prentice-Hall Of India (P) Ltd , Latest Edition , Total Quality Management – An Introductory Text, Paul James ,Prentice-Hall Of India (P) Ltd , Latest Edition , Electronic Device And Circuits- An Introduction, Allen Mottershed,Prentice-Hall Of India (P) Ltd , Latest Edition , Techniques Of Press Working Sheet Metal, Donald F. Eary. & Edward A. Reed ,Prentice-Hall Of India (P) Ltd , Latest Edition , Essentials Of Management, Joseph L.Massie ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Elements Of Electrical Engineering, Maria Louis ,Prentice-Hall Of India (P) Ltd , Latest Edition , Digital Electronics, William H.Gothmann ,Prentice-Hall Of India (P) Ltd , Latest Edition , Programmable Logic Controllers – Principle And Applications, John W. Webb ,Prentice-Hall Of India (P) Ltd , Latest Edition , Computer Networks, Andrew S.Tanenbaum ,Prentice-Hall Of India (P) Ltd , 2002 , Data And Computer Communications, William Stallings ,Prentice-Hall Of India (P) Ltd , Eighth Edition 2007 , Computer System Architecture, M.Morris Mano ,Prentice-Hall Of India (P) Ltd , 3Rd Edition , Data Structures A Programming Approach With C, Dharmender Singh Kushwaha And Arun Kumar Misra ,Prentice-Hall Of India (P) Ltd , 2012, Latest Reprint , Classic Data Structures, Debasis Samanta ,Prentice-Hall Of India (P) Ltd , 2Nd Edition , The Internet, Douglas E.Comer ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Introduction To Biomedical Instrumentation, Mandeep Singh,Prentice-Hall Of India (P) Ltd , Latest Edition , Iso 9001, Brain Rethry, Brain Rethry ,Productivity And Quality Publishing Pvt. Ltd. , 1993 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 2008 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 23Rd Edition , Limit State Theory And Design Of Reinforced Concrete, S.R.Karve And V.L.Shah ,Puna Vidyarthi Griha, Prakashan , 5Th Edition , A Course In Electrical And Electronics Measurements And Instrumentation, A.K. Sawhney ,Puneet Sawhney Dhanpat Rai & Co (P) Ltd. , Latest Edition , Upgrading And Repairing Laptops, Scott Mueller ,Que Publication , Latest Edition , A Text Book Of Fluid Mechanics And Hydraulic Machines,By, R. K Rajput And S.Chand ,R. K Rajput And S.Chand & Co, New Delhi , Latest Edition , Training Manual On Iso 9001 : 2000 & Tqm, Girdhar J.Gyani ,Raj Publishing House , Latest Edition , Electrical Machine Design, A.Naoor Kani ,Rba Publications , Latest Edition , A Course In Electrical Engineering , B.L.Theraja ,S.Chand & Company Ltd, New Delhi ,Reprint 2006 , A Text Book Of Transportation Engineering, S P Chandola ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R.S.Khurmi ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R. S. Khurmi, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Production Technology , P. C. Sharma ,S.Chand & Company Ltd, New Delhi ,Edn. X , Thermal Engineerin, , R.S. Khurmi, J.K Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , A Text Book Of Hydraulics, Fluid Mechanics And Hydraulic Machines,R.S. Khurmi ,S.Chand & Company Ltd, New Delhi ,Edn.18 , Thermal Engineering, R.S. Khurmi And J.K. Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , The Automobile, Harbans Singh Reyat, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Non Conventional Energy Sources And Utilisation , R.K. Rajput - S.Chand ,S.Chand & Company Ltd, New Delhi , 2012 , A Text Book Of Electrical Technology Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , A Text Book Of Electrical Technology -Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , Principles Of Power System, V.K.Metha ,S.Chand & Company Ltd, New Delhi , 4Th Edition Reprint 2007 , Electronic Measurements And Instrumentation, R.K.Rajput ,S.Chand & Company Ltd, New Delhi , 3Rd Edition 2009 , Computer Concepts And C, Dr.S.S.Khandare ,S.Chand & Company Ltd, New Delhi , 1St Edition 2010, Latest Reprint , Electrical Technology Vol I And Ii, B.L.Theraja ,S.Chand & Company Ltd, New Delhi , Mutiple Colour Edition,2012 , Principles Of Electronics, V.K.Mehta ,S.Chand & Company Ltd, New Delhi , Second Edition , Electronics And Instrumentation, Dr.S.K.Battachariya Dr. Renu Vig ,S.K. Kataria & Sons, New Delhi , Latest Edition , Principles Of Electrical Machine Design, R.K.Agarwal ,S.K. Kataria & Sons, New Delhi , Latest Edition , Environmental Engineering And Management, Dr.Suresh K.Dhameja- ,S.K. Kataria & Sons, New Delhi , Latest Edition , Soil Mechanics & Foundation Engineering, V N S Murthy ,Sai Kripa Technical Consultants , Latest Edition , Digital Communications, Dr.K.N.Hari Bhat Dr.D.Ganesh Rao ,Sanguine Technical Publisher , Latest Edition , Energy Resource Management, Kirpal Singh Jogi- Sarup And Sons ,Sarup And Sons , Latest Edition , A Course In Electrical And Electronic Measurement And Instrumentation, Umesh Sinha ,Satya Prakashan, New Delhi , Latest Edition , Electrical And Electronics Measurements And Instrumentation, Umesh Sinha ,Satyaprakashan Tech , 1992 , Theory And Problems Of Machine Design, Holowenko, Laughlin ,Schaum’S Outline Series. , Latest Edition , Data Structures With C, Seymour Lipschutz ,Schaums Outlines, Tmh , Latest Reprint , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication , Latest Edition , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication, Chennai. , Latest Edition , Limit State Design Of Concrete Structures, Dr.S.Ramachandra ,Scientific Publishers , Latest Edition , Murach’S Mysql, Joel Murach ,Shroff / Murach , 2012, Latest Reprint , Fundamentals Of Tool Design, Dr.John G.Nee ,Society Of Manufacturing Engineers. , Latest Edition , Electrical Machine Design, C.Eswarlal ,Sonaversity , Latest Edition , A Concise Introduction To Software Engineering, Pankaj Jalote ,Springer, Latest Edition , Design Of Electrical Machine, Mittle V.N ,Standard Book – House , Latest Edition , Fluid Mechanics, P.N. Modi & S.M. Sethi ,Standard Publishers & Distributors, New Delhi , Latest Edition , Water Supply And Sanitary Engineering Vol I & Ii, Gurcharan Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Hydraulics, Fluid Mechanics And Hydraulics Machines, K.R. Arora ,Standard Publishers & Distributors, New Delhi , Latest Edition , Automobile Engineering Vol- 1, Vol – 2,Kirpal Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Learning Material Development Project,,Taramani, Chennai, Cd Programme On Gps And Gis , Latest Edition , Principles Of Transportation & Highway Engineering, G V Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, N.N. Basak ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, A.Kamala,D.L.Kanthrao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Engineering Hydrology, K.Subramanya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Production And Operations Management, S.N. Chary ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Essentials Of Management, Koontz &Weihrich ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Business Correspondence & Report Writing, R.C. Sharma And K.Mohan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , How To Prepare For Group Discussion & Interview (With Audio Cassette), Prasad ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Construction Management And Planning, Sengupta.B, &H.Guha ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Applications In Construction, Boyd.C. & Paulson Jr ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Fluid Mechanics And Machinery, B C S Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Geotechnical Earthquakes Engineering Hand Book,,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials, S.S.Rattan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials,B K Sarkar ,Tata Mcgraw-Hill Publishing Company Ltd , I Edition, 2003 , Production Technology,,Tata Mcgraw-Hill Publishing Company Ltd ,Edn. 18. 2001 , Autocad With Applications, Sham Tickoo,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynami, Pk Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , Production Technology, Hmt, ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 18 , Manufacturing Process, Myro N Begman ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 5 , Production Processes, Nitttr, ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Circuits & System- Analog And Digital , Y.N.Bapat ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynamics, P.K. Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Ndedition , Quality Management, Howard Cuitlow ,Tata Mcgraw-Hill Publishing Company Ltd , 1998 , Quality Planning And Analysis, Juran J.M And Frank M.Gryna Jr. ,Tata Mcgraw-Hill Publishing Company Ltd , 1982 , Tool Design, Donaldson ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Non-Conventional Energy Resources ,B.H.Khan ,Tata Mcgraw-Hill Publishing Company Ltd ,2Nd Edn, 2009. , Cad/Cam Principles And Applications, Dr.P.N.Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cad/Cam, Ibrahim Zeid ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Measurement Systems, E. O. Doebelin ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Robotics And Image Processing, Janakiraman.P.A ,Tata Mcgraw-Hill Publishing Company Ltd , 1995 , Circuits And Networks Analysis And Synthesis., A. Sudhakar Shyammohan S Palli ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electric Circuits, Mahamood Nahvi Joseph A Edminister ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Nagarath ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Bhattacharya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Jacob Millman And Halkias ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Optical Fiber Communication, Gerdkeise ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Instrumentation, Hs Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P.Jains ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles & Applications, Albert Paul Malvino & Donaldp.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Introduction To Microprocessor, Aditya P Mathur ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Power System Protection And Switchgear, B Ram & Dn Viswakarma ,Tata Mcgraw-Hill Publishing Company Ltd , Reprint 2000 , Programmable Logic Controllers, Frank D.Petruzella ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Power Distribution System, As Pabla ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Utilization Of Electric Power, Nv Suryanarayana ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Troubleshooting, Maintaining And Repairing Pcs, Stephen J Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , 2006 , Computer Networks, Achyut Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices And Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2016 , Electronic Principles , Malvino ,Tata Mcgraw-Hill Publishing Company Ltd , 2010 , Electronicsdevices And Circuits, Jacobmillmanandhalkias ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2010 , Electronic Instrumentation, Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Programming In Ansi C , E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Programming And Problem Solving Using C, Isrd Group, Lucknow ,Tata Mcgraw-Hill Publishing Company Ltd , 2008 , Electronic Communication Systems, Kennedy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, Arvind M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Communication Electronics Principles And Application , Louis E Frenzel ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles And Applications, Albert Paul Malvino & Donald P.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Linear Integrated Circuits, Salivahanan & V.S.Kanchana Baskaran ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Communication Systems, Kennedy – Davis ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Communication, P.Ramakrishna Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Principles Of Communications System, Taub &Schilling ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Tata Mcgraw-Hill Publishing Company Ltd , Second Edition 2010 , Troubleshooting, Maintaining And Repairing Pcs, Stephen J.Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , Fifth Edition , Ibm Pc And Clones, B.Govindrajalu ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, By A.M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Color Tv, Theory And Practice, S.P.Bali ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P. Jain ,Tata Mcgraw-Hill Publishing Company Ltd , Third Reprint 2010 , Basic Electricall Engineering, V.N.Mittle ,Tata Mcgraw-Hill Publishing Company Ltd , First Edition , Basic Electrical And Electronics Engineering, R,Muthusubramanian R.Salivajanan ,Tata Mcgraw-Hill Publishing Company Ltd , Seventh Reprint 2011 , Computer Architecture And Organization, John P. Hayes ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Data Communication And Networking, Behrouz A.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Computer Communications And Networks, Achyuts.Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cryptography And Network Security, Behrouza.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Programming With Java, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Data Structures And Algorithms, G.A.Vijayalakshm I Pai ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Reprint Or Latest Reprint , Data Structures Using C, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Programming In C#, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Applications Of .Net Technology, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , 1St Edition Or Latest Reprint , Cloud Computing A Practical Approach 2008 Edition, Cloud Computing A Practical Approach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Software Engineering, Stephen Schach ,Tata Mcgraw-Hill Publishing Company Ltd , Eight Reprint 2011 , Mobile Computing, Asoke K Talukder,Hasan Ahmed, Roopa R Yavagal ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Multimedia: Making It Work., Tay Vaughan ,Tata Mcgraw-Hill Publishing Company Ltd , 8Th Edition , Multimedia Communication Systems: Techniques, Standards, And Networks, K.R. Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Principles Of Multimedia, Ranjan Parekh ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , The Complete Reference Linux, Richard Peterson ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Edition , A Text Book Of Engineering Drawing,R.B. Gupta ,Technical India Publications, New Delhi , Latest Edition , Digital Communication, Dr. J.S.Chitode ,Technical Publications – Pune , Latest Edition , Introduction To Plc, Gary Dunning ,Thomson Del Mar Learning , 3Rd Edition , Data Structures Using C – 1000 Problems And Solutions, Sudipta Mukherjee ,Tmgh, New Delhi , 2Nd Reprint Or Latest Reprint , Industrial & Power Electronics, Harish C.Rai ,Umesh Publications , 2017 , Construction Engineering & Management, Seetharaman. S ,Umesh Publications , Latest Edition , Introduction To Earthquake Engineering,,University Of Tokyo Press , Latest Edition , Digital Electronics And Logic Design, Jaydeep Chakravarthy ,University Press, Hyderabad , First Edition2012 , Introduction To Data Structures Using C, Venkatesh N.Baitipuli ,University Science Press, Chennai , 1St Edition, 2009 Or Latest Reprint , Software Engineering, Rohit Khurana ,Vikas Publishing Ltd , Second Edition , Organizational Behaviours, S.Chandran ,Vikas Publishing Ltd , Latest Edition , Operating Systems, Rohit Khurana ,Vikas Publishing Ltd , 2Nd Edition , Workshop Technology, Waj Chapman ,Vima Books Pvt. Ltd New Delhi , Latest Edition , Energy Auditing In Electrical Utilities, Rajiv Shankar ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Workshop Tech Vol I,Ii, Iii, Waj. Chapman ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Wireless And Mobile Network Architectures, Yi-Binglin, Imrich Chlamtac ,Wiley , Latest Edition , Wireless Networks, P. Nicopolitidis ,Wiley , Latest Edition , Operating System Concepts, Abraham Siberschatz, Galvin, Gagne ,Wiley , 9Th Edition , Microprocessor Architecture Programming And Application, Ramesh S. Gaonkar, ,Wiley Eastern Ltd , Latest Edition , Introduction To System Design Using Ic, B.S. Sonde ,Wiley Eastern Ltd , Latest Edition , Fundamentals Of Acoustics, Kingsler And Frey,Wiley Eastern Ltd , Latest Edition , Beginning Android 4 Application Development, Wei-Meng Lee ,Wiley India Edition , Latest Edition , Power Electronics, Mohan, Undeland, Robbins. ,Wiley India Edition. , Media Enhanced Third Edition , Web Programming, Chris Bates ,Wiley India, New Delhi, 3Rd Edition , Cloud Security: A Comprehensive Guide To Secure Cloud Computing, Ronald L. Krutz Russell Dean Vines ,Wiley Publishing, Inc , Latest Edition , Cloud Computing Bible, Barrie Sosinsky ,Wiley Publishing, Inc. , Latest Edition , Total Quality Management For Engineers, Zeiri ,Wood Head Publishers , 1991 , Mechanics Of Structures- Vol 1, S.B.Junnarkar , , Latest Edition , I S 2185 Part I & Ii, Ernest O. Doebelin , , Latest Edition , Pwd & Cpwd Specifications, D.V.S.Murty , , Latest Edition , National Building Code,, , Nbc-2012 , Tamilnadu District Municipal Building Rules And By-Laws,, , Latest Edition , Civil Engineering Drawing And House Planning, B.P. Verma , , Latest Edition , Building Planning And Drawings, Dr N. Kumaraswamy And A. Kameswara Rao , , Latest Edition , Building Planning And Construction, G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , , Latest Edition , Civil Engineering Drawing, S.C.Rangwala , , Latest Edition , A Guide To Civil Engineering Drawing, V.R.Thothathri , , Latest Edition , Theory Of Structures, S. Ramamrutham , , Latest Edition , Analysis Of Structures, V.N. Vazirani & M.M. Ratwani , , Latest Edition , Elementary Theory Of Structures, R.L. Jindal , , Latest Edition , Strength Of Materials, Fv. Warnock , , Latest Edition , Estimating & Costing, Bridie , , Latest Edition , Indian Standard Code Of Practice, Is:1200,, , Latest Edition , I S 456-2000 ; I S 875-1987; I S 800 -2007,, , Latest Edition , Explanatory Hand Book Sp24, Design Aid Sp 16,Detailing Of Reinforcement,Sp 34,, , Latest Edition , Concrete Technology , M.S. Shetty , , Latest Edition , Fire Resistant Construction – Building Construction, S.P.Arora And S.P.Bindra , , Second Edition , Earth Quake Proof , Dr.Janardhanjha And Prof.Suresh Kumar , , Latest Edition , Sinha Is Code Of Practice For Earth Quake , Is Code Of Practice For Fire Resistance, Is Code Of Practice For Pre Stressing,, , Latest Edition , Pile Foundation, Rd Chellis, Mis , , Latest Edition , Construction And Foundation Engineering, Sinha & Janatha Shau , , Latest Edition , Principle Fine Safety Standards For Building Construction, M.Ya Roytman , , Second Edition , Remote Sensing And Geographical Information Systems, Anji Reddy.M. (1998) , , Latest Edition , Analysis And Design Of Substructures (Lsd) – Second Edition 2010, Swami Saran , , Latest Edition , Civil Engineering Drawing, M Chakrabort , , Latest Edition , Civil Engineering Drawing, Gurucharan Singh & Subhash Chandar Sharma , , Latest Edition , Civil Engineering Drawing Manual, S Chand & Company (Pvt) Ltd. , , Latest Edition , Production Systems: Planning, Analysis And Control, J.L.Riggs, 3Rd Ed , , Latest Edition , Productions And Operations Management, A.Muhlemann, J.Oakland And K.Lockyer, Macmillan , , Latest Edition , Operations Research, J.K.Sharma, Macmillan , , Latest Edition , Spoken English – A Self-Learning Guide To Conversation Practice (With Cassette),, , Latest Edition , Quality Control And Applications, Housen&Ghose , , Latest Edition , Industrial Engineering Management, O.P. Khanna , , Latest Edition , Steel Structures, Dr.Subramaniam , , Latest Edition , Town Planning, S.C. Rangwala , , Latest Edition , Town Planning, K.S.Rangwala And P.S.Rangwala , , Latest Edition , Remote Sensing Methods And Application, Michael Hord, R , , Latest Edition , National Building Code Of India- Part-Iii.(2005),, , Latest Edition , Municipal And Panchayat Bye-Laws, Cmda Rules And Corporation Bye-Laws.,, , Latest Edition , Urban And Regional Planning, Ka. Ramegowda , , Latest Edition , Earthquake Resistant Design Of Structures, Pankaj Agarwal And Manish Shrikhande , , Latest Edition , Guidelines For Earthquake Resistant Non Engineered Construction, The Associated Cement Companies Ltd , , Latest Edition , Criteria For Earthquake Resistant Design Of Structures - General Provisions And Buildings, Is: 1893 ( Part 1 ) - 2002,, , Latest Edition , Code Of Practice For Ductile Detailing Of Rc Structures Subjected To Seismic Forces, Is:13920-1993.,, , Latest Edition , Earthquake Tips, C.V.R.Murty, , , Latest Edition , Indian Standard Code Of Practice, Is:1200.,, , Latest Edition , Estimating And Costing, Vazirani & Chandolu , , Latest Edition , Geometrical And Machine Drawing, N.D. Bhatt, Anand , , Latest Edition , Hydraulics, Andrew Parr , , Latest Edition , Fundamentals Of Pneumatic Control Engineering, Festo Manual , , Latest Edition , Electrical Technology, Hughes, , 8Th Edition , Machine Design Bandari,,, , Latest Edition , Industrial Engineering & Management, O.P Khanna , , Latest Edition , Industrial Engineering & Production Management, Martand Telsang , , Latest Edition , Production Engineering , P.C.Shrma. , , Latest Edition , Production And Costing, Gbs Narang And V.Kumar , , Latest Edition , Mechanical Estimating And Costing , Banga & Sharma. , , Latest Edition , Quality Auditing, D.Mills, Chapman And Hall , , 1993 , Refrigeration And Air Conditioning, V.K. Jain, , , Latest Edition , Industrial Refrigeration Hand Book, Wilbert F. Steocker , , Latest Edition , A Course In Refrigeration And Air Conditioning , Domkundwar , , Latest Edition , Principles Of Refrigeration, Dossat, , Latest Edition , Electronic Principles , Malvino , , Latest Edition , Microcontrollers, Principles And Applications – Ajit Pal – Phi Ltd., - 2011.,, , Latest Edition , Biomedical Instrumentation ,Anuradha Publications, Chennai, Dr.M. Arumugam , , Latest Edition , Bio Medical Instrumentation And Measurements, Ii Edition., Leslie Cromwell –Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering., Jacobson And Webstar , , Latest Edition , Hand Book Of Bio –Medical Instrumentation., R.S .Khandpur , , Latest Edition , Medical Electronics, Kumara Doss , , Latest Edition , Introduction To Medical Electronics, B.R. Klin , , Latest Edition , Introduction To Biomedical Instrumentation , Mandeep Singh Printice Hall India 2010. , , Latest Edition , Digital Communications, John G.Prokais , , 2011 , Biomedical Instrumentation And Measurements, Leslie Cromwell, Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering, Jacobson And Webstar , , Latest Edition , Hand Book Of Bio–Medical Instrumentation., R.S .Khandpur , , Latest Edition , Engineering Mathematics - Dr.M.K.Venkatraman, National Publishing Co, Chennai 2. , Engineering Mathematics – Dr.P.Kandasamy & Others, S.Chand & Co Ltd, New Delhi , Physics, Resnick And Haliday–Wisley Toppan Publishers–England , Engineering Physics–B.L.Theraja–S. Chand Publishers , A Text Book Of Sound–R.L. Saighal & H.R. Sarna–S.Chand & Co. , Mechanics–Narayana Kurup–S. Chand Publishers. , Fundamentals Of Physics – Brijlal And Subramaniam. , Fundamentals Of Electricity – D.N. Vasudeva – S. Chand & Co , Non-Conventional Energy Sources – G.D. Rai.- Khanna Publishers , Text Book Of Remote Sensing And Geographical Information Systems – M. Anji Reddy Bs Publications. , Engineering Chemistry – Jain & Jain – Dhanpat Rai & Sons. , A Text Book Of Engineering Chemistry – S.S. Dara – S. Chand Publication. , A Text Book Of Environmental Chemistry And Pollution Control – S.S. Dara – S. Chand Publication. , Engineering Chemistry – Uppal – Khanna Publishers. , Environmental Chemistry – V P Kudesia – Pragati Publishers. , Chemistry Of Engineering Material – C.V. Agarwal, Andranaidu C. Parameswara Moorthy – B.S. Publications. , A Text Book Of Inorganic Chemistry – P.L. Soni – S. Chand Publication. , Rain Water Harvesting – Hand Book – Chennai Metro Water. , Bhatt N.D. And Panchal V.M., “Engineering Drawing”, Charotar Publishing House, 50Th Edition, 2010. , Gill P.S., “Engineering Drawing”, S.K.Kataria & Sons. , Gopalakrishnan.K.R., Engineering Drawing, (Vol.I And Vol.Ii), Dhanalakshmi Publishers, Edition 2 , Venugopal.K, Sreekanjana G, “Engineering Graphics” New Age International Publishers. , K V Nataraajan “A Text Book Of Engineering Drawing” , Besant Agrawal, C M Agrawal “Engineering Drawing”, Tata Mcgraw Hill Education Private Limited. , Barkinson & Sinha, First Year Engineering Drawing, Pitman Publishers. , Communication Skill, Sanjay Kumar Pushp Lata, Oxford University Press , Communication Skill, , Gph Publication , English Communication Teory And Practical, Manoj Kumar Garg, Scholar Tech Press , Little Redbook - Grammar Made Easy, Terry O Brien
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
19.
Water Resources and Irrigation #10024112 AOC
Tender for Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50Mt. & Lift Of 1.5 Mtr Etc Complete As Per The Direction Of The Engineer-Incharge. , Excavation In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical 60% & Mannual 40%) , Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-Incharge. , Cement Concrete (1:4:8) With 4Cm Size H.G.B. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc. Complete As Per The Direction Of The Engineer-Incharge. , Pcc/Rcc Cement Concrete (1:2:4) With 12Mm Size Black C.B. Hand Broken Chips Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Conveyance Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc Complete As Per The Direction Of The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Super Structure Etc. Complete As Per The Engineer-Incharge. , 12Mm Thick Plaster In Cement Mortar (1:6) Finished Smooth To Brick Massonary After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Reinforced Cement Concrete Lintel Data (For 9.00 Sqms.) , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Roof Slab, Reinforced Cement Concrete Floor, Landing Balcony, Projection Sun Shed & Chajja, Sheles Data (For 9.00 Sqms.) , Labour Charge For M.S. Reinforcement For Reinforced Cement Concrete Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Steel Bar (Fe 415/ Fe 500) , Cement Punning Over Plastering Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , 2.5 Cm (1) Thick Artificial Stone Flooring With Cement Concrete(1:2:4) Including Punning Using 12 Mm Size Hard , Cost Of M.S. Fabricated Door & Window Including Fitting And Fixing Charges Etc. Complete. (Size Door 3Ft X 6Ft) (W- 2Ft X 3Ft) , 2.5 Cm Thick Grading Concrete (1:2:2) On Roof Slab With 6Mm Size H.G (C.B) Chips On New Work Including All Cost Etc. Complete. , White Washing Two Coats With Shell Lime , Distempering Two Coats To Wall , Wiring Of Pump Chamber , Cost Of Out Let Of Tee Tank , Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-Incharge. , Filling In F&P With Excavated Materials Including Well Watered And Rammed.In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical Plus Mannual I.E. Of Item No. 5 Above) , Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-Incharge. , 100Mm Dia Nominal Bore G.I.Pipe Having Wall Thickness 4.5Mm Electrical Resistance Welded Of Medium Class Confirming To Is- 1239(Part-1/2004) With Latest Ammendments, Screwed At Both Ends As Per Is-554 With Socketed At One End And The Other End Protected With Plastic Threaded Protector Including Its Transportation And Unloading At L.I.P. Site. The Socket Confirming To Isi 1239(Part Ii/1992) With Latest Ammendments In Random Length Of 4 To 7 Mtr.Each Pipe Should Bear Is Certification And Manufacturers Name/Trade Mark. (As Per special repair 2022) , 100Mm Dia G.I.Bend ( Medium Duty) Conforming To Is No-1239 (Part Ii/1992) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia G.I.Flange (Medium Duty) Conforming To Is No-6392/1971 With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia C.I. Screw Boss Foot Valve Of Swing Type Friction Less With Single Disc Conforming To Is-4038/1979 Of Reputed Brand With Isi Mark Of Reputed Company Having Wide Dealership Network Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (Kirlosker Make) , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 200Mmdia Hdpe Pipe Pe 80-Pn4 , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 160 Mmdia Hdpe Pipe Pe 80-Pn4 , Transportation Of 200 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , Transportation Of 160 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , 100Mm Dia C.I.Sluice Valve Flanged Type Pn-1.0 As Per (Is-14846-2000 Standard) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , 100Mm Dia C.I.Double Flanged Non Return Valve Swing Type Pn-1.0 (Is-5312(Part-I-2004) With Bypass Arrangement With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost, Supplying Of 25Mm Dia Kirloskar Make C.I Single Air Release Valve (Standard) Pn 1.6 With Saddle And Raiser Pipe Conforming To Is 14845 (Si) With Isi Mark Including All Cost, Conveyance, Cess Etc Complete , Cost Of 200 X 200 X 100 Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 160 Mm X 160 Mm X 110 Mm Ø Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 100X100x25mm G.I. Tee With Plug For Priming , 219Mm Dia M.S.Pipe (6.30Mm Thickness) Is 3589:2001 With Isi Mark Of Reputed Company Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost Of 12Mm Thick Ms Plate Flange 200Mm Dia Isi Mark Of Reputed Company , 200 Mm Hdpe Tail Piece 160 Mm Long , 200 Mm Slipon Flange , 160 Mm Hdpe Tail Piece 160 Mm Long , 160 Mm Slipon Flange , Cost Of Welding & Laying Fitting 200Mm M.S. Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 200Mm Hdpe Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 160Mm Hdpe Pipe , Labour Charges For Delivery And Fitting Including Fitting Of Priming Tee, Sluice Valve, Nr Valve, Air Release Valve And Riser Tee Etc And Installation , Cost Of Rubber Insertion 3Mm Thick , Cost Of Nut Bolt , 150Mm Dia C.I. Butter Fly Valve Bs:5155/15: Kirloskar Or Equivalent Make 13095-Ci Moc Lever Operated Pn-1.0 With Isi Mark Of Reputed Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022 , 200 Mm Hdpe Elbow Spigot Design 6 Kg , 160 Mm Hdpe Elbow Spigot Design 6 Kg , Cost Of 200Mmx100mm M S Reducer , 200X200x200 Mm Hdpe Tee Spigot Design 6 Kg , 200X200x160 Mm Spigot Moulded Reducing Hdpe Tee 10 Kg , 160X160x160 Mm Hdpe Tee Spigot Design 6 Kg , 200 Mm Hdpe End Cap , 160 Mm Hdpe End Cap , 12.5 Hp/9.375 Kw Energy Efficiency Monoblock Pump Set Of Total Head 24 Mtrs Having Discharge 1700 Lpm With Squirrel Cage Induction Motor Fitted With Bronze Impeller Tb-2 Of Is 318/1981, Companion Flanges & Class FInsulation Suitable For Operation 415 Volt +6%-15% 3 Phase, 50Hz Ac Poweer Supply Suction/Deliveery= 100Mmx100mm With Bee 3 Star Rated Energy Efficiency Pump & As Per Is-9079/2002 With Overall Efficiency 62 To 65% Of Reputed Brand Having Wide Dealership Net Work For Easy Availability Of Spares Confirming To Is Specification (A) Casing: Fc 200 As Per Is 210/1978 (B) Impeller: Bronze Grade Ltb-2 Of Is 318/1981 Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Automatic Star Delta Starter Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Upto 15 Hp (13-20) With 16. annual periodical maintenance (Ac-3) Contactor At 415 Volt +6%-15%, 3 Phase, 50 Hz, Ac Supply With Suitable Overload Relay & No Volt Coil With Electric Pnemutic Timer Suitable For Operation At Voltage Range Of 300-440 Volt Including Cost Of Transportation To Site The Starter Should Provide Dependable Protection Against Overload And Single Phasing & Should Be Of Reputed Brand Having Wide Dealership Network For Easy Availability Of Spares Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 63 annual periodical maintenance Triple Pole Mainswith Confirming To Is No.4064(Part I & Ii) With Isi Marking Of Reputed Company Having Utilisation Capacity Cagegory Ac- 22 Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Empty Outdoor Irrigation Pannel Board Size (0.45Mtx0.25Mtx1.20M Of 18 Swg Cold Rolled M.S Sheet With 4 Legs Of 300 Size With One Coat Of Red Oxide Primer And Two Coats Of Smoke Grey /Navy Blue Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Mount 3Phase Starter, Main Switch And Capacitor Inside The Panel Board Vertically Over 18 Swg M.S.Sheet And The Danger Board Fixed On The Top Of The Panel Doorreputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Motor Hood Size (0.45Mx0.45Mx0.60M) Made With 18 Swg (Cold Rolled M.S.Sheet With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Attachement With The Groves On Rear Side Of The Pannel Board Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , Motor Base Plate Made With M.S Angle With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Hole For Fixing Nut & Bolt Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , 4Kvar Power Shunt Capacitor With Isi Mark Of Of Reputed Approved Brand Of Isi Marked Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Cost Of 3/16Mm2 T.D Cabel , Cost Of Other Petty Materials Like Connection Wire And Cabel Laying In Trench & Energisation , Electrical Installation , Tranporation, Energisation & Including By Party Agreement. , Kit Bag Including Plyer, Tester, Slide Range, Screw Driver, Hand Gloves All Are In Taparia Make To Be Hahded Over To The Panipanchayat , Cost Of Electrical Earthing , Construction And Erection Of 11/0.416 Kv 25 Kva Star Rated Dp Sub-Stationconfirming To Re Rule 1956. Mounted On 2.44 Mt Long Structure, Supported On 10 Mt Long Psc Pole, Transformer Hard Channel & Top Channel Made Of 2.8 Mtr Long 100X50x6 Mm Size Ms Channel, Transformer Belting On 2.80 Mtr Long 50X50x5mm Size M.S. Angle, (All Recspn. Std. F-3), With All Accessories Like, 3 Pole 11 Kv H.G. Fuse (F-5) Abd Ab Swithces (F-9) Both Mounted On 2.8 Mtr Long 75X40x6 Mm Size M.S. Channel And Supported By 1.0 Mtr Long 50X50x5 Mm M.S. Angle, With 3 Nos. 11 Kv Lightening Arrestor & Distribution Box For 25 Kva S/S Mounted On Box ( 75X40x6 Mm) To 2.5 Mtr Long Pipe Earthing (F-2) Including Cost Of 50 Sq Mm 3.5 Core Lt Cable Connecting The Supply Line With 55 Sq Mm Aaa Conductor, Providing G.I. Ht Stay As Required Carping & Padding Of Poles, Danger Board At Each Pole. ., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3 Phase 11 Kv Line As Per Rec Stanard Confirming To Re Rules 1956 With 10 Mt Long Psc Pole Support In 50 Mtr Span, 55 Sq Mm Aaa Conductor, 11 Kv V Cross Arm, With Required No Of 11 Kv T & C Disc. Insulators & 11 Kv Pin Insulators, Carping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point And Double Stay At End Point With 18 Mm G.I. H.T Stay, Concreting Of Stay With Anchor Plate Guarding At Road Crossing Etc., Marking Olic In Every Psc Pole In Enamale Paint Including Cost Of All Materials. With Ab Switch & Interposing Pole, Labour Trasportation, Inspection And Commissioning With Cut Point Etc., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3-Phase, 4-Wire Lt Line As Per Rec Standard Confirming To Re Rules 1956, With 9 Meter Long Psc Pole Support In 50 Meter Span, 3X35+1X25 Sqmm Ab Cable, Required Numbers Of 16 Mm Lt Gi Stay-Set At Bending Point And Double Stay At End Point With Required Numbers Of Suspension Clamp,Dead End Clamp And Lt Stay Insulator, Providing Coil Earthing At Each Pole ,Carping And Padding Of Poles, Danger Board At Each Pole With Anti-Climbing Device Etc. Including Cost Of All Other Fittings, Petty Materials, All Labours, With Liaison For Inspection And Commissioning& Writing On The Pole As Per Prescribed Colour Code, Etc, Complete As Per The Direction Of The Site Engineer In Charge .
Contract Date: Apr 20, 2026 Contract Value : 28.43 Lakh
Government Departments No of Bidders 3
20.
Water Resources and Irrigation #10024111 AOC
Tender for Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50Mt. & Lift Of 1.5Mtr Etc Complete As Per The Direction Of The Engineer-Incharge. , Excavation In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical 60% & Mannual 40%) , Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-Incharge. , Cement Concrete (1:4:8) With 4Cm Size H.G.B. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc. Complete As Per The Direction Of The Engineer-Incharge. , Pcc/Rcc Cement Concrete (1:2:4) With 12Mm Size Black C.B. Hand Broken Chips Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Conveyance Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc Complete As Per The Direction Of The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Super Structure Etc. Complete As Per The Engineer-Incharge. , 12Mm Thick Plaster In Cement Mortar (1:6) Finished Smooth To Brick Massonary After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Reinforced Cement Concrete Lintel Data (For 9.00 Sqms.) , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Roof Slab, Reinforced Cement Concrete Floor, Landing Balcony, Projection Sun Shed & Chajja, Sheles Data (For 9.00 Sqms.) , Labour Charge For M.S. Reinforcement For Reinforced Cement Concrete Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Steel Bar (Fe 415/ Fe 500) , Cement Punning Over Plastering Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , 2.5 Cm (1) Thick Artificial Stone Flooring With Cement Concrete(1:2:4) Including Punning Using 12 Mm Size Hard , Cost Of M.S. Fabricated Door & Window Including Fitting And Fixing Charges Etc. Complete. (Size Door 3Ft X 6Ft) (W- 2Ft X 3Ft) , 2.5 Cm Thick Grading Concrete (1:2:2) On Roof Slab With 6Mm Size H.G (C.B) Chips On New Work Including All Cost Etc. Complete. , White Washing Two Coats With Shell Lime , Distempering Two Coats To Wall , Wiring Of Pump Chamber , Cost Of Out Let Of Tee Tank , Cost Of 300 Mm Dia Reinforced Cement Concrete Hum Pipe( Np 3 ) As Per Specifications Including Laying & Fitting With Collars As Required. , Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-Incharge. , Filling In F&P With Excavated Materials Including Well Watered And Rammed.In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical Plus Mannual I.E. Of Item No. 5 Above) , Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-Incharge. , 100Mm Dia Nominal Bore G.I.Pipe Having Wall Thickness 4.5Mm Electrical Resistance Welded Of Medium Class Confirming To Is- 1239(Part-1/2004) With Latest Ammendments, Screwed At Both Ends As Per Is-554 With Socketed At One End And The Other End Protected With Plastic Threaded Protector Including Its Transportation And Unloading At L.I.P. Site. The Socket Confirming To Isi 1239(Part Ii/1992) With Latest Ammendments In Random Length Of 4 To 7 Mtr.Each Pipe Should Bear Is Certification And Manufacturers Name/Trade Mark. (As Per special repair 2022) , 100Mm Dia G.I.Bend ( Medium Duty) Conforming To Is No-1239 (Part Ii/1992) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia G.I.Flange (Medium Duty) Conforming To Is No-6392/1971 With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia C.I. Screw Boss Foot Valve Of Swing Type Friction Less With Single Disc Conforming To Is-4038/1979 Of Reputed Brand With Isi Mark Of Reputed Company Having Wide Dealership Network Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (Kirlosker Make) , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 200Mmdia Hdpe Pipe Pe 80-Pn4 , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 160 Mmdia Hdpe Pipe Pe 80-Pn4 , Transportation Of 200 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , Transportation Of 160 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , 100Mm Dia C.I.Sluice Valve Flanged Type Pn-1.0 As Per (Is-14846-2000 Standard) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , 100Mm Dia C.I.Double Flanged Non Return Valve Swing Type Pn-1.0 (Is-5312(Part-I-2004) With Bypass Arrangement With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost, Supplying Of 25Mm Dia Kirloskar Make C.I Single Air Release Valve (Standard) Pn 1.6 With Saddle And Raiser Pipe Conforming To Is 14845 (Si) With Isi Mark Including All Cost, Conveyance, Cess Etc Complete , Cost Of 200 X 200 X 100 Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 160 Mm X 160 Mm X 110 Mm Ø Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 100X100x25mm G.I. Tee With Plug For Priming , 219Mm Dia M.S.Pipe (6.30Mm Thickness) Is 3589:2001 With Isi Mark Of Reputed Company Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost Of 12Mm Thick Ms Plate Flange 200Mm Dia Isi Mark Of Reputed Company , 200 Mm Hdpe Tail Piece 160 Mm Long , 200 Mm Slipon Flange , 160 Mm Hdpe Tail Piece 160 Mm Long , 160 Mm Slipon Flange , Cost Of Welding & Laying Fitting 200Mm M.S. Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 200Mm Hdpe Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 160Mm Hdpe Pipe , Labour Charges For Delivery And Fitting Including Fitting Of Priming Tee, Sluice Valve, Nr Valve, Air Release Valve And Riser Tee Etc And Installation , Cost Of Rubber Insertion 3Mm Thick , Cost Of Nut Bolt , 150Mm Dia C.I. Butter Fly Valve Bs:5155/15: Kirloskar Or Equivalent Make 13095-Ci Moc Lever Operated Pn-1.0 With Isi Mark Of Reputed Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022 , 200 Mm Hdpe Elbow Spigot Design 6 Kg , 160 Mm Hdpe Elbow Spigot Design 6 Kg , Cost Of 200Mmx100mm M S Reducer , 200X200x200 Mm Hdpe Tee Spigot Design 6 Kg , 200X200x160 Mm Spigot Moulded Reducing Hdpe Tee 10 Kg , 160X160x160 Mm Hdpe Tee Spigot Design 6 Kg , 200 Mm Hdpe End Cap , 160 Mm Hdpe End Cap , 12.5 Hp/9.375 Kw Energy Efficiency Monoblock Pump Set Of Total Head 24 Mtrs Having Discharge 1700 Lpm With Squirrel Cage Induction Motor Fitted With Bronze Impeller Tb-2 Of Is 318/1981, Companion Flanges & Class FInsulation Suitable For Operation 415 Volt +6%-15% 3 Phase, 50Hz Ac Poweer Supply Suction/Deliveery= 100Mmx100mm With Bee 3 Star Rated Energy Efficiency Pump & As Per Is-9079/2002 With Overall Efficiency 62 To 65% Of Reputed Brand Having Wide Dealership Net Work For Easy Availability Of Spares Confirming To Is Specification (A) Casing: Fc 200 As Per Is 210/1978 (B) Impeller: Bronze Grade Ltb-2 Of Is 318/1981 Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Automatic Star Delta Starter Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Upto 15 Hp (13-20) With 16. annual periodical maintenance (Ac-3) Contactor At 415 Volt +6%-15%, 3 Phase, 50 Hz, Ac Supply With Suitable Overload Relay & No Volt Coil With Electric Pnemutic Timer Suitable For Operation At Voltage Range Of 300-440 Volt Including Cost Of Transportation To Site The Starter Should Provide Dependable Protection Against Overload And Single Phasing & Should Be Of Reputed Brand Having Wide Dealership Network For Easy Availability Of Spares Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 63 annual periodical maintenance Triple Pole Mainswith Confirming To Is No.4064(Part I & Ii) With Isi Marking Of Reputed Company Having Utilisation Capacity Cagegory Ac- 22 Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Empty Outdoor Irrigation Pannel Board Size (0.45Mtx0.25Mtx1.20M Of 18 Swg Cold Rolled M.S Sheet With 4 Legs Of 300 Size With One Coat Of Red Oxide Primer And Two Coats Of Smoke Grey /Navy Blue Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Mount 3Phase Starter, Main Switch And Capacitor Inside The Panel Board Vertically Over 18 Swg M.S.Sheet And The Danger Board Fixed On The Top Of The Panel Doorreputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Motor Hood Size (0.45Mx0.45Mx0.60M) Made With 18 Swg (Cold Rolled M.S.Sheet With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Attachement With The Groves On Rear Side Of The Pannel Board Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , Motor Base Plate Made With M.S Angle With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Hole For Fixing Nut & Bolt Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , 4Kvar Power Shunt Capacitor With Isi Mark Of Of Reputed Approved Brand Of Isi Marked Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Cost Of 3/16Mm2 T.D Cabel , Cost Of Other Petty Materials Like Connection Wire And Cabel Laying In Trench & Energisation , Electrical Installation , Tranporation, Energisation & Including By Party Agreement. , Kit Bag Including Plyer, Tester, Slide Range, Screw Driver, Hand Gloves All Are In Taparia Make To Be Hahded Over To The Panipanchayat , Cost Of Electrical Earthing , Construction And Erection Of 11/0.416 Kv 25 Kva Star Rated Dp Sub-Stationconfirming To Re Rule 1956. Mounted On 2.44 Mt Long Structure, Supported On 10 Mt Long Psc Pole, Transformer Hard Channel & Top Channel Made Of 2.8 Mtr Long 100X50x6 Mm Size Ms Channel, Transformer Belting On 2.80 Mtr Long 50X50x5mm Size M.S. Angle, (All Recspn. Std. F-3), With All Accessories Like, 3 Pole 11 Kv H.G. Fuse (F-5) Abd Ab Swithces (F-9) Both Mounted On 2.8 Mtr Long 75X40x6 Mm Size M.S. Channel And Supported By 1.0 Mtr Long 50X50x5 Mm M.S. Angle, With 3 Nos. 11 Kv Lightening Arrestor & Distribution Box For 25 Kva S/S Mounted On Box ( 75X40x6 Mm) To 2.5 Mtr Long Pipe Earthing (F-2) Including Cost Of 50 Sq Mm 3.5 Core Lt Cable Connecting The Supply Line With 55 Sq Mm Aaa Conductor, Providing G.I. Ht Stay As Required Carping & Padding Of Poles, Danger Board At Each Pole. ., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3 Phase 11 Kv Line As Per Rec Stanard Confirming To Re Rules 1956 With 10 Mt Long Psc Pole Support In 50 Mtr Span, 55 Sq Mm Aaa Conductor, 11 Kv V Cross Arm, With Required No Of 11 Kv T & C Disc. Insulators & 11 Kv Pin Insulators, Carping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point And Double Stay At End Point With 18 Mm G.I. H.T Stay, Concreting Of Stay With Anchor Plate Guarding At Road Crossing Etc., Marking Olic In Every Psc Pole In Enamale Paint Including Cost Of All Materials. With Ab Switch & Interposing Pole, Labour Trasportation, Inspection And Commissioning With Cut Point Etc., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3-Phase, 4-Wire Lt Line As Per Rec Standard Confirming To Re Rules 1956, With 9 Meter Long Psc Pole Support In 50 Meter Span, 3X35+1X25 Sqmm Ab Cable, Required Numbers Of 16 Mm Lt Gi Stay-Set At Bending Point And Double Stay At End Point With Required Numbers Of Suspension Clamp,Dead End Clamp And Lt Stay Insulator, Providing Coil Earthing At Each Pole ,Carping And Padding Of Poles, Danger Board At Each Pole With Anti-Climbing Device Etc. Including Cost Of All Other Fittings, Petty Materials, All Labours, With Liaison For Inspection And Commissioning& Writing On The Pole As Per Prescribed Colour Code, Etc, Complete As Per The Direction Of The Site Engineer In Charge .
Contract Date: Apr 20, 2026 Contract Value : 28.76 Lakh
Government Departments No of Bidders 2
21.
Water Resources and Irrigation #10024110 AOC
Tender for Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50Mt. & Lift Of 1.5Mtr Etc Complete As Per The Direction Of The Engineer-Incharge. , Excavation In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical 60% & Mannual 40%) , Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-Incharge. , Cement Concrete (1:4:8) With 4Cm Size H.G.B. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc. Complete As Per The Direction Of The Engineer-Incharge. , Pcc/Rcc Cement Concrete (1:2:4) With 12Mm Size Black C.B. Hand Broken Chips Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Conveyance Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc Complete As Per The Direction Of The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Super Structure Etc. Complete As Per The Engineer-Incharge. , 12Mm Thick Plaster In Cement Mortar (1:6) Finished Smooth To Brick Massonary After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Reinforced Cement Concrete Lintel Data (For 9.00 Sqms.) , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Roof Slab, Reinforced Cement Concrete Floor, Landing Balcony, Projection Sun Shed & Chajja, Sheles Data (For 9.00 Sqms.) , Labour Charge For M.S. Reinforcement For Reinforced Cement Concrete Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Steel Bar (Fe 415/ Fe 500) , Cement Punning Over Plastering Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , 2.5 Cm (1) Thick Artificial Stone Flooring With Cement Concrete(1:2:4) Including Punning Using 12 Mm Size Hard , Cost Of M.S. Fabricated Door & Window Including Fitting And Fixing Charges Etc. Complete. (Size Door 3Ft X 6Ft) (W- 2Ft X 3Ft) , 2.5 Cm Thick Grading Concrete (1:2:2) On Roof Slab With 6Mm Size H.G (C.B) Chips On New Work Including All Cost Etc. Complete. , White Washing Two Coats With Shell Lime , Distempering Two Coats To Wall , Wiring Of Pump Chamber , Cost Of Out Let Of Tee Tank , Cost Of 300 Mm Dia Reinforced Cement Concrete Hum Pipe( Np 3 ) As Per Specifications Including Laying & Fitting With Collars As Required. , Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-Incharge. , Filling In F&P With Excavated Materials Including Well Watered And Rammed.In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical Plus Mannual I.E. Of Item No. 5 Above) , Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-Incharge. , 100Mm Dia Nominal Bore G.I.Pipe Having Wall Thickness 4.5Mm Electrical Resistance Welded Of Medium Class Confirming To Is- 1239(Part-1/2004) With Latest Ammendments, Screwed At Both Ends As Per Is-554 With Socketed At One End And The Other End Protected With Plastic Threaded Protector Including Its Transportation And Unloading At L.I.P. Site. The Socket Confirming To Isi 1239(Part Ii/1992) With Latest Ammendments In Random Length Of 4 To 7 Mtr.Each Pipe Should Bear Is Certification And Manufacturers Name/Trade Mark. (As Per special repair 2022) , 100Mm Dia G.I.Bend ( Medium Duty) Conforming To Is No-1239 (Part Ii/1992) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia G.I.Flange (Medium Duty) Conforming To Is No-6392/1971 With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia C.I. Screw Boss Foot Valve Of Swing Type Friction Less With Single Disc Conforming To Is-4038/1979 Of Reputed Brand With Isi Mark Of Reputed Company Having Wide Dealership Network Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (Kirlosker Make) , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 200Mmdia Hdpe Pipe Pe 80-Pn4 , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 160 Mmdia Hdpe Pipe Pe 80-Pn4 , Transportation Of 200 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , Transportation Of 160 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , 100Mm Dia C.I.Sluice Valve Flanged Type Pn-1.0 As Per (Is-14846-2000 Standard) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , 100Mm Dia C.I.Double Flanged Non Return Valve Swing Type Pn-1.0 (Is-5312(Part-I-2004) With Bypass Arrangement With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost, Supplying Of 25Mm Dia Kirloskar Make C.I Single Air Release Valve (Standard) Pn 1.6 With Saddle And Raiser Pipe Conforming To Is 14845 (Si) With Isi Mark Including All Cost, Conveyance, Cess Etc Complete , Cost Of 200 X 200 X 100 Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 160 Mm X 160 Mm X 110 Mm Ø Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 100X100x25mm G.I. Tee With Plug For Priming , 219Mm Dia M.S.Pipe (6.30Mm Thickness) Is 3589:2001 With Isi Mark Of Reputed Company Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost Of 12Mm Thick Ms Plate Flange 200Mm Dia Isi Mark Of Reputed Company , 200 Mm Hdpe Tail Piece 160 Mm Long , 200 Mm Slipon Flange , 160 Mm Hdpe Tail Piece 160 Mm Long , 160 Mm Slipon Flange , Cost Of Welding & Laying Fitting 200Mm M.S. Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 200Mm Hdpe Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 160Mm Hdpe Pipe , Labour Charges For Delivery And Fitting Including Fitting Of Priming Tee, Sluice Valve, Nr Valve, Air Release Valve And Riser Tee Etc And Installation , Cost Of Rubber Insertion 3Mm Thick , Cost Of Nut Bolt , 150Mm Dia C.I. Butter Fly Valve Bs:5155/15: Kirloskar Or Equivalent Make 13095-Ci Moc Lever Operated Pn-1.0 With Isi Mark Of Reputed Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022 , 200 Mm Hdpe Elbow Spigot Design 6 Kg , 160 Mm Hdpe Elbow Spigot Design 6 Kg , Cost Of 200Mmx100mm M S Reducer , 200X200x200 Mm Hdpe Tee Spigot Design 6 Kg , 200X200x160 Mm Spigot Moulded Reducing Hdpe Tee 10 Kg , 160X160x160 Mm Hdpe Tee Spigot Design 6 Kg , 200 Mm Hdpe End Cap , 160 Mm Hdpe End Cap , 12.5 Hp/9.3 Kw Energy Efficiency Monoblock Pump Set Of Total Head 24 Mtrs Having Discharge 1700 Lpm With Squirrel Cage Induction Motor Fitted With Bronze Impeller Tb-2 Of Is 318/1981, Companion Flanges & Class FInsulation Suitable For Operation 415 Volt +6%-15% 3 Phase, 50Hz Ac Poweer Supply Suction/Deliveery= 100Mmx100mm With Bee 3 Star Rated Energy Efficiency Pump & As Per Is-9079/2002 With Overall Efficiency 62 To 65% Of Reputed Brand Having Wide Dealership Net Work For Easy Availability Of Spares Confirming To Is Specification (A) Casing: Fc 200 As Per Is 210/1978 (B) Impeller: Bronze Grade Ltb-2 Of Is 318/1981 Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Automatic Star Delta Starter Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Upto 15 Hp (13-20) With 16. annual periodical maintenance (Ac-3) Contactor At 415 Volt +6%-15%, 3 Phase, 50 Hz, Ac Supply With Suitable Overload Relay & No Volt Coil With Electric Pnemutic Timer Suitable For Operation At Voltage Range Of 300-440 Volt Including Cost Of Transportation To Site The Starter Should Provide Dependable Protection Against Overload And Single Phasing & Should Be Of Reputed Brand Having Wide Dealership Network For Easy Availability Of Spares Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 63 annual periodical maintenance Triple Pole Mainswith Confirming To Is No.4064(Part I & Ii) With Isi Marking Of Reputed Company Having Utilisation Capacity Cagegory Ac- 22 Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Empty Outdoor Irrigation Pannel Board Size (0.45Mtx0.25Mtx1.20M Of 18 Swg Cold Rolled M.S Sheet With 4 Legs Of 300 Size With One Coat Of Red Oxide Primer And Two Coats Of Smoke Grey /Navy Blue Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Mount 3Phase Starter, Main Switch And Capacitor Inside The Panel Board Vertically Over 18 Swg M.S.Sheet And The Danger Board Fixed On The Top Of The Panel Doorreputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Motor Hood Size (0.45Mx0.45Mx0.60M) Made With 18 Swg (Cold Rolled M.S.Sheet With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Attachement With The Groves On Rear Side Of The Pannel Board Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , Motor Base Plate Made With M.S Angle With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Hole For Fixing Nut & Bolt Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , 4Kvar Power Shunt Capacitor With Isi Mark Of Of Reputed Approved Brand Of Isi Marked Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Cost Of 3/16Mm2 T.D Cabel , Cost Of Other Petty Materials Like Connection Wire And Cabel Laying In Trench & Energisation , Electrical Installation , Tranporation, Energisation & Including By Party Agreement. , Kit Bag Including Plyer, Tester, Slide Range, Screw Driver, Hand Gloves All Are In Taparia Make To Be Hahded Over To The Panipanchayat , Cost Of Electrical Earthing , Construction And Erection Of 11/0.416 Kv 25 Kva Star Rated Dp Sub-Stationconfirming To Re Rule 1956. Mounted On 2.44 Mt Long Structure, Supported On 10 Mt Long Psc Pole, Transformer Hard Channel & Top Channel Made Of 2.8 Mtr Long 100X50x6 Mm Size Ms Channel, Transformer Belting On 2.80 Mtr Long 50X50x5mm Size M.S. Angle, (All Recspn. Std. F-3), With All Accessories Like, 3 Pole 11 Kv H.G. Fuse (F-5) Abd Ab Swithces (F-9) Both Mounted On 2.8 Mtr Long 75X40x6 Mm Size M.S. Channel And Supported By 1.0 Mtr Long 50X50x5 Mm M.S. Angle, With 3 Nos. 11 Kv Lightening Arrestor & Distribution Box For 25 Kva S/S Mounted On Box ( 75X40x6 Mm) To 2.5 Mtr Long Pipe Earthing (F-2) Including Cost Of 50 Sq Mm 3.5 Core Lt Cable Connecting The Supply Line With 55 Sq Mm Aaa Conductor, Providing G.I. Ht Stay As Required Carping & Padding Of Poles, Danger Board At Each Pole. ., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3 Phase 11 Kv Line As Per Rec Stanard Confirming To Re Rules 1956 With 10 Mt Long Psc Pole Support In 50 Mtr Span, 55 Sq Mm Aaa Conductor, 11 Kv V Cross Arm, With Required No Of 11 Kv T & C Disc. Insulators & 11 Kv Pin Insulators, Carping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point And Double Stay At End Point With 18 Mm G.I. H.T Stay, Concreting Of Stay With Anchor Plate Guarding At Road Crossing Etc., Marking Olic In Every Psc Pole In Enamale Paint Including Cost Of All Materials. With Ab Switch & Interposing Pole, Labour Trasportation, Inspection And Commissioning With Cut Point Etc., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3-Phase, 4-Wire Lt Line As Per Rec Standard Confirming To Re Rules 1956, With 9 Meter Long Psc Pole Support In 50 Meter Span, 3X35+1X25 Sqmm Ab Cable, Required Numbers Of 16 Mm Lt Gi Stay-Set At Bending Point And Double Stay At End Point With Required Numbers Of Suspension Clamp,Dead End Clamp And Lt Stay Insulator, Providing Coil Earthing At Each Pole ,Carping And Padding Of Poles, Danger Board At Each Pole With Anti-Climbing Device Etc. Including Cost Of All Other Fittings, Petty Materials, All Labours, With Liaison For Inspection And Commissioning& Writing On The Pole As Per Prescribed Colour Code, Etc, Complete As Per The Direction Of The Site Engineer In Charge .
Contract Date: Apr 20, 2026 Contract Value : 26.27 Lakh
Government Departments No of Bidders 2
22.
Defence #9966685 AOC
Tender For Provision Of Otm Accommodation At Saugor Under Ge Saugor.; 2 GENERAL SUMMARY 3 Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’Part-I (Ref prepriced schedule attached seperately) 4 Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART- II (INTERNAL WATER SUPPLY WORKS) as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-III (INTERNAL ELECTRIFICATION WORKS ) as listed in Schedule ‘A’Part -III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor forSCHEDULE ‘A’ PART-IV (EXTERNAL ELECTRIC SUPPLY WORKS) as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor forSCHEDULE A PART-V (SEWAGE DISPOSAL WORKS) as listed in Schedule ‘A’Part-V (Ref prepriced schedule attached seperately) 8 Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-VI(ROAD, PATH AND CULVERT WORKS) as listed in Schedule ‘A’Part-VI(Ref prepriced schedule attached seperately) 9 Lump sum price worked out by the contractor forSCHEDULE A PART-VII (AREA DRAINAGE WORKS) as listed in Schedule ‘A’Part-VII(Ref prepriced schedule attached seperately) 10 Lump sum price worked out by the contractor for SCHEDULE A PART- VIII (COMPOUND WALL, FENCING AND GATE WORKS) as listed in Schedule ‘A’Part-VIII(Ref prepriced schedule attached seperately) 11 Lump sum price worked out by the contractor forSCHEDULE A PART-IX (RETAINING WALL WORKS) as listed in Schedule ‘A’Part-IX(Ref prepriced schedule attached seperately) 12 Lump sum price worked out by the contractor forSCHEDULE ‘A’ PART-X (CONDUIT FOR TV & TELEPHONE WIRING WORKS)as listed in Schedule ‘A’Part-X(Ref prepriced schedule attached seperately) 13 Lump sum price worked out by the contractor forSCHEDULE ‘A’ PART-XI (SOLAR ROOF TOP SYSTEM WORKS) as listed in Schedule ‘A’Part-XI(Ref prepriced schedule attached seperately) 14 Lump sum price worked out by the contractor forSCHEDULE ‘A’ PART-XII (EXTERNAL WATER SUPPLY WORKS)as listed in Schedule ‘A’Part-XII(Ref prepriced schedule attached seperately) 15 Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XIII (EXCAVATION, EARTH WORK & SITE CLEARANCE WORKS) as listed in Schedule ‘A’Part- XIII (Ref prepriced schedule attached seperately) 16 Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XIV ( DEMOLITION / DISMANTLINGWORKS) as listed in Schedule ‘A’Part- XIV (Ref prepriced schedule attached seperately) 17 SCH A Pt - XV (MISCELLANEOUS ITEMS) 18 Ext Electric Supply NOTE:- For items of Ext Electric Supply notes given at the beginning of Sch ‘A’ Part-IV ( Ext Electric Supply) shall also be applicable. 19 M&L for supply, installation, connecting and commissioning ofCPRI approved main LT distribution ACB, outdoor type, both side openable including locking arrangement with sliding door bolt, cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15mm thick MS sheet with anti-corrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) ACB, 4 Pole, 415V, 50HZ 800 Amps with rupturing capacity 36 KA-01Nos(B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Bus bar chamber having insulatedaluminium, each suitable for 800 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 400 Amps with rupturing capacity 36 KA-02 Nos(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 10 KA-01Nos(vi) 3 phase street light timer of capacity5 KW at 415V = 01 20 M&L for supply, installation, connecting and commissioning ofCPRI approved main LT distribution panel, outdoor type, both side openable including locking arrangement with sliding door bolt, cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anti-corrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 300 Amps with rupturing capacity 36 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Bus bar chamber having insulatedAluminium for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with rupturing capacity 16 KA-02 Nos(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 10 KA-04Nos 21 M&L for supply, installation, connecting and commissioning ofCPRI approved main LT distribution panel, outdoor type, both side openable including locking arrangement with sliding door bolt, cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15mm thick MS sheet with anti-corrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 400 Amps with rupturing capacity 36 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulatedAluminium busbar, each suitable for 400 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 160 Amps with rupturing capacity 25 KA-01 Nos(v) MCCB, 4 Pole,415V, 50HZ 40 Amps with rupturing capacity 10 KA-04Nos(vi) MCB SPN 240V, 50HZ 40 Amps,10KA -08Nos(vii) MCB SPN 240V, 50HZ 63 Amps 10KA -01Nos 22 M&L for supply, installation, connecting and commissioning ofCPRI approved main LT distribution panel, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15mm thick MS sheet with anti-corrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 100 Amps with rupturing capacity 25 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, each suitable for 100 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 36 KA-01 Nos(v) MCCB, 4 Pole,415V, 50HZ 40 Amps with rupturing capacity 10 KA- 03Nos(vi) MCB SPN 240V, 50HZ 32 Amps, 10KA-01Nos(vii) MCB SPN 240V, 50HZ 40 Amps,10KA-01Nos 23 Supply & fix junction box single pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12 x 10 x4 complete all as specified and directed.Make : Sintex/ Hensel 24 S&F tubes galvanised 40mm bore light grade ISI Marked bent to shape of bracket 1.2 mtr in length for mounting of street light fitting and fixed to pole with clamps and nut bolt and washer with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 25 Taking down old existing transformer and shifting into MES substation yard complete all as specified and directed. 26 SEWAGE DISPOSAL NOTE:- For items of Sewage Disposal notes given at the beginning of Sch ‘A’ Part-V ( Sewage Disposal) shall also be applicable. 27 S&F HDPE double wall corrugated sewagepipe 150mm internal bore SN-8 ISI Mark as per IS: 6908 Part II 2013 laid in trenches joined and tested as per manufacturers instructions complete all as specified and directed. 28 Construction of RCC septic tank designed to carry sewage and sludge water including excavation and earth work in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users (CONVENTIONAL pattern) complete all as specified and directed. 29 Construction RCC septic tank designed to carry sewage and sludge water including excavation and earth work in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users (CONVENTIONAL pattern) complete all as specified and directed. 30 Construction RCC septic tank designed to carry sewage and sludge water including excavation and earth work in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users (CONVENTIONAL pattern) complete all as specified and directed. 31 Construction of soakage wells including excavation and earth work in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 Design Mix concrete including intercepting chamber and screen chamber made ofbrick masonry in CM, RCC cover slab in M25/SFRC cover, inter-connecting pipes of RCC/DWC complete filled with brick bats2.40m x 3.00m effective depth complete all as specified and shown on drawing No TD NoCEBZ/TD/78/2011. 32 COMPOUND WALL, FENCING AND GATE WORKS NOTE:- For items of COMPOUND WALL, FENCING AND GATE WORKS notes given at the beginning of Sch ‘A’ Part-VIII ( COMPOUND WALL, FENCING AND GATE WORKS) shall also be applicable. 33 Provision of steel gate 5.50m wide in double leaf, including RCC (M-25) pillars, excavation and earth work, formwork, reinforcement bars, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, three coats of white wash over plastered surfaces of pillars complete all specified and shown on Drg No CEBZ/STD/104 of 2011. 34 Provision of steel gate 8.00m wide in double leaf, including RCC (M-25) pillars, excavation and earth work, formwork, reinforcement bars, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, three coats of white wash over plastered surfaces of pillars complete all specified and shown on Drg No CEBZ/STD/104 of 2011. 35 (CONDUIT FOR TV & TELEPHONE WIRING WORKS)NOTE:- For items of CONDUIT FOR TV & TELEPHONE WIRING WORKS notes given at the beginning of Sch ‘A’ Part-X ( CONDUIT FOR TV & TELEPHONE WIRING WORKS) shall also be applicable. 36 S&F RJ 11 telephone socket with shutter, 1 module including modular cover plate, metal flush box (16 gauge) concealed in wall/roof complete all as specified anddirected. 37 S&F RJ 45 computer jack with cat no 6 socket, 1 module including modular cover plate, metal flush box (16 gauge) concealled in wall/roof complete all as specified and directed. 38 SOLAR ROOF TOP SYSTEM)WORKS NOTE:- For items of SOLAR ROOF TOP SYSTEM)WORKS notes given at the beginning of Sch ‘A’ Part-XI ( SOLAR ROOF TOP SYSTEM)WORKS) shall also be applicable. 39 Design, supply, installation, testing and commissioning of ON Grid connected roof top solar generation system of capacity not less than 55 KWp AC capacity all as specified in PS and directed as per PS clause and specification as follows (for (For Adm Bldg):-(A) Supply, Installation, testing and commissioning of not less than 55 KWp SPV system comprising of latest specification DCR solar photo voltic modules/array of high efficiency made of mono crystalline silicon solar PV cells with supply and fix of terminal box on the module havingprovision for opening & replacing the cable etc.as per IEC. The general features of PV modules shall be as given below :- a) The module shell be made up mono crystalline silicon cells.b) The interconnected cells shall be laminatedin vacuum to withstand adverse environmental conditions. c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm.e) Surge arresting devices to be provided at junction box and module shall be provided with bypass diode.f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies.g) Each solar PV module must be warranted by manufacturer at least 90% rated power at the end of 10 years & 80% at the end of 25 years. Note: Qty of PV module shall be decided as per OEM recommendation, design and layout drawing submitted to department duly approved by GE. 40 Note :-(i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 5% spare qty of modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost.(iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:-(v) Name of the manufacturer of PV Module(vi) Name of the Manufacturer of Solar cells(vii) Month and year of the manufacture for solar cells and the module(viii) Country of origin (Make in INDIA only)(ix) I-Vcurve for the module(x) Wattage, Im, Vm and FF for the module(xi) Unique Serial No and Model No of the module(xii) Date and year of obtaining IEC PV module qualification certificate(xiii) Name of the test lab issuing EC certificate(xiv) Other relevant information on traceability of solar cells & module. 41 (B) Module Mounting Structure (MMS) :-Supply & fixing of the anti-corrosive factory made Gl structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, nuts & bolt. The minimum thickness of galvanization & mounting steel structure shall be as per IS 47592 & IS 2061-1992 respectively withstand the wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. Note:-(i)The total load for roof top SPV should be less than 60 Kg/m2.(ii) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submittedby the contractor duly vetted from IIT/NIT/Govt Engg college for approval by GE.(iii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iv)The fasteners should be of stainless steel and should allow easy replacement of any module.(v) The minimum clearance of the structure from the roof level should be 300 mm. 42 (C) Solar DC Cables:- (i) Supply & laying of 1.1kv single core multi strandedPVC FRLSH insulated & unsheathed copper wire/ copper cable for 3 ph supply in ISI marked PVC rigid conduit pipe by saddling as per IEC. (For Solar Array DC supply connection). Note : (i) The size of cable shall be as per design given by OEM & approved by GE.(ii)Cable should be passes through PVC rigid pipe and pipe should be fixed properly inside cable tray for easily maintenance, is included in quoted rate(D) DC Combine boxA DC combine box shall be used to combine the DC cables of the solar module array with DC fuse protection for the outgoing DC cables to the DC distribution box. 43 (E) Array junction boxes_-The number of junction boxes as per design given by OEM are to be provided in the PV array for termination of connecting cables. All wire/cables must be terminated through cable lugs. Copper busbar/terminated blocks housed in the junction box conforming to IP 65 degree of protection with EPDM rubber gasket to prevent water entry. Junction boxes shall be mounted on the MMS such that they are easily accessible and protected from direct sunlight & harsh weather. (F) On Grid Power Conditioning unit ( Inverter):-Supply & installation of 415V 3-ph, 50 Hz microprocessor DSP type grid connected Inverters which converts DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power source on site. Provisioning of power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 10% & frequency variation +/-3 Hz)Note :-(i) No of inverters shall be provisioned as per design given by OEM. (ii) Inverter should have internal protection arrangements against any sustainable fault in feeder line and against the lightning on feeder.(iii) Should have isolating transformer(iv) Inverter efficiency >93% with inbuilt galvanic isolation) (v) No load losses shall be less than 1% of rated power.(vi) The above quoted rate is inclusive of MS structure stand duly fixed and placing inverter. 44 (G) Solar meter & Net meter:-As per DISCOM requirement, to be provided at main MRS. Cost of Solar meter & Net meter, installation, connected accessories, necessory liasioning with DISCOM are included in quoted Rates. If DISCOM desires installation of above meters through deposit work including NOC if required, then cost of deposit shall be made by contractor and amount shall be included in quoted rates.(H) AC Distribution Board:-(i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from Inverter & provided by nacessary surge arrestors system and suitable capacity MCCBs.; Qty-01 No Note: ACDB shall be provided as per OEM design as approved by GE.(J) AC Cables:-(ii) Distribution wiring in 1.1kv single core multi stranded PVC FRLSH insulated & unsheathed copper wire fixed on wall on PVC batten or saddle(For AC power supply from Inverter to AC distribution board Panel).Note :- (i) The size of cable shall be as per design given by OEM & approved by GE. 45 (K) Protection:-The system shall be provided with all necessary protection like earthing, lightening & surge protection as per relevant standard.(L) Performance testing:-Ratio between the theoretical energy outputs of the SPV plant is termed as performance ratio and is measured in accordance with IEC 61724. Based on prevailing climatic and temperature conditions in India, a performance ratio of 75% is expected for crystalline modules. (M) Other Misc items:-As per requirement given by OEM and approved by GE to be provided.(N) Earthing:_As per MNRE specifications to be provided.(O) Lightening protection:-As per MNRE specifications to be provided.(P) Installation, Testing & Commissioning:-As per safety norms of SERC/CEA to be provided.(Q) O&M and Warranty:-5 years from the date of commissioning to be provided. 46 Note: The quoted rate is deemed to be inclusive also of the following:-(i) Transportation charges with Transportation Insurance for the all material of on grid solar roof top system including loading & unloading at site from workshop.(ii) Insurance for the complete system for the 5 years.(iii) AMC-Suraksha which include 24 Hour site maintenance visits, response time 2 hrs and turn around time 48 hrs, Monthly plant performance report. (iv) As per performance obligation, the contractor shall maintain minimum capacity utilization factor (CUF) of 13%. The report shall be submitted by the contractor to GE as per guidelines promulgated by SECI. (v) Satisfactorily testing and commissioning of the system is to be done by the contractor in presence of the rep of accepting officer and the report of the complete system is submitted to department.(vi) Guarantee and warranty of solar panel and connected devices is to be submitted to department. (vii) The report of generated unit of solar power on monthly basis is to be submitted to office. 47 (viii) The cost of appropriate civil structure (Hot Dip Galvanised Iron structure) shall be included in quoted rate. The Civil structure incorporating Solar PV modules (arrays) should withstand the gusts of wind /cyclonic wind upto 150 km/hr from backside of panel.(ix) PV modules will be guaranteed against any manufacturing defect for 10 Years.(x) The contractor shall submitt design vetted from National Institute of Solar Energy or by Govt Institute authorised by MNRE or NISE or any reputed institute/ agency authorised.(xi) The quoted rate shall be inclusive of all the components as specifed here-in-above as well as Particular Specification, unless otherwise specified.(xii). Suitable fastening arrangement such as grouting and calming should be provided to secure the installation against the specific wind speed. The Empanelled Agency shall be fully responsible for any damages to SPV System caused due to high wind velocity within guarantee period as per technical specification. 48 All as per the description of Serial Item No 39 here-in-before but of 35 kwp AC capacity (ONE for Single Living Accn & One for Cook House Cum Dining Hall ). 49 Supply and fixing heavy duty self priming monoblock pump for cleaning of Solar Panel through pressure and fitted on mild steel base plate, having discharge of 638 gallon/hour at a pressure head of 15-42m complete with standard accessories including 1-HP, single phse, 220V rating electric motor complete with DOL starter of suitable rating complete all as specified and directed. 50 Supply and fix flexible, anti-twist, weather resistant, UV resistant thick water hose PVC pipe of size 15mm nominal dia for optimal water flow with leak proof tap adapter compatible with delivery pipe of mono-block pump (as specified in above item) with suitable reducer/enlarger with clamp for cleaning and washing of solar panels complete all as specified and directed. Note :- Make or quality as approved by GE. 51 Supply and fix adjustable type water spray gun compatible with PVC hose size of 15mm nominal dia, built of high quality brass material, durable and rust-proof, solid brass structure to ensure quick connection and with durable accessories, can withstand uptoPSI water pressure, and without any leakage of water complete all as specified and directed.Note :- Make or quality as approved by GE. 52 EXT WATER SUPPLYWORKS NOTE:- For items of EXT WATER SUPPLYWORKS notes given at the beginning of Sch ‘A’ Part-XII (EXT WATER SUPPLYWORKS) shall also be applicable. 53 Supply, laying, connecting, jointing and testing Centrifugally cast (spun ) 150mm dia ductile iron pressure pipe ISI Marked conforming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of following size with socket spigot ends, suitable for Push on Joints ( Tyton Joint ) each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including Push on Joint supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenchescomplete all as specified and directed 54 Supply, laying, connecting, jointing and testing centrifugally cast ( Spun ) 80mm dia Ductile iron Pressure pipe ISI Marked confirming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of following size with socket spigot ends, suitable for Push on Joints (Tyton Joint ) each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including Push on Joint supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete all as specified and directed. 55 M&L for bends (any type, radius and angle) tapers and y type, (straight, bends increasing, decreasingor double socket etc.( Tee pieces single branch, Y junction, double branch, cross (all socketed or socket and spigot) collars caps and plugs complete all as specified and directed. 56 S&F 300mm dia sluice valve CI body ISI marked class PN 1.6 heavy duty flanged ends cast iron wheel with brass spindle (ISI marked) conforming to IS:14786-2000, short body all as specified including nuts, bolt, washers and gasket complete all as specified and directed 57 M&L for construction of brick masonry valve pit chamber of size 1200 x 1200 x1000mm including necessory earth work, PCC, copping plastering on internal surfaces of valve pit. Framed work for the valve pit chamber cover made of MS sheet 3mm thick conforming to Fe410-o and Fe 310-o, angle of size 40 x 40 x 5mmincluding welding, cutting, hinges locking arrangement complete and applying two coats synthetic enamel paint over a coat of red oxide primer on the valve pit cover complete all specified and directed. 58 M&L for construction of brick masonry valve pit chamber of size 900 x 900 x 600mm including necessory earth work, PCC, copping, plastering on internal surface of valve pit. Framed work for the valve pit chamber cover made of MS sheet 3mm thick confirming to Fe410-o and Fe 310-o, angle of size 40 x 40 x 5mm including welding, cutting, hinges locking arrangement complete and applying two coats synthetic enamel paint over a coat of red oxide primer on the valve pit cover complete all specified and directed 59 SCHEDULE ‘A’ PART – XV ( DEMOLITION / DISMANTLINGWORKS) 60 Taking down main switch, DB box including MCBs of capacity complete all as specified and directed. 61 Taking down services connection including disconnecting from pole DG/main switch complete all as specified and directed. 62 SCHEDULE A PART - XIII (ARBORICULTURE WORKS) 63 Supply and planting of following species of well grown (4 to 5 feet height)trees sampling with good roots including excavating a pit of size 2 feet x 2 feet x 2 feet in any type of soil & fill with the pit with Jaivik manure & suitable earth, including watering & spraying pestisides, fungisides etc. tying with aproximate 6 feet bamboo for supporting the plant wherever necessary & also replacing the dead plant/ sampling & its regular watering & maintanance till completion of two years maintanance period including spraying fungicides as and when required complete all as specified and directed. 64 Bottle Palm 65 Fish Tail Palm 66 Fox Tail Palm 67 Gulmohar 68 Bougainvillea 69 Ashoka Tree 70 Golden Shower 71 Jacaranda 72 Rain Tree 73 Heges ( 0.50 feet height) 74 Musanda 75 Agave 76 Crape mytale 77 Supply and planting of lawn carpet for landscaping including watering of carpet andwherever necessary & also replacing the dead plant/sampling & its regular watering & maintanance till completion of two years maintanance period including spraying fungicides as and when required complete all as specified and directed 78 Supply and installation for watering the following accessories:- 79 Pump & Pump Accessories 80 Filter 81 Valve 82 Pressure gauge 83 Air Valve 84 Fartigation Unit 85 Sprinkler 86 Unioun 87 Sadal 88 Pipe 2 inche including fittings 89 Pipe 1.5 inche & fittigs 90 Drip laternal tube 91 Micro connector 92 Wire and other control system 93 Pipe attachment and fittings 94 Cost of trannsportation & installation of Trees 95 Cost of installation and maintanace (2 years after completion) of drip irrigationand connected to main water supply etc complete all as specified and directed. 96 Preparation & levelling ofground for lawn carpert grass and plants complete all as specified and directed. 97 Maintanance of all plants, shrubs, lawn grass, etc for a period of 02years after certified comletion of subject work by employing skilled gardners any number as required on site per day to ensure healing up, keep of watering plants, pour manure, carying out periodic tilling and use pestisides, cutting grass and removing unwanted grass & plants at work site complete all as specified and directed.
Contract Date: Jun 30, 2026 Contract Value : 35.68 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
Madhya Pradesh View Result →
23.
Educational and Research Institute #9736323 Technical Bid
Tender For supply of Lab Items , Lab Items , Apparatus To Determine Rydbergs Constant , Apparatus To Determine Temperature Coefficient Of Resistance Of Platinum , Digital Storage Oscilloscope (Dual Channel, 20 Mhz) , Callendar And Barnes Apparatus For Mechanical Equivalent Of Heat , Function Generator (1 Hz To 10 Mhz) , Series And Parallel Resonance Circuit Experimental Setup , Sodium Vapour Lamp With Inbuilt Constant Power Supply , Mercury Vapour Lamp With Inbuilt Constant Power Supply , Soldering And De-Soldering Tool Set , Resistance Box (Multiple Ranges) , Digital Multimeter (True Rms) , Moment Of Inertia Experimental Setup (Parallel And Perpendicular Axis) , Modulus Of Rigidity By Dynamic Method Apparatus , Surface Tension By Capillary Rise Method Apparatus , Viscosity By Poiseuilles Method Apparatus , Conversion Of Mechanical Energy Into Heat Apparatus , Heating Efficiency Of Electric Kettle Apparatus , Platinum Resistance Thermometer Experimental Setup , Lees Disc Apparatus For Thermal Conductivity , Determination Of Wavelength Of Diode Laser By Diffraction , Vibration Magnetometer Experimental Setup , Tangent Galvanometer Experimental Setup , Junction Field Effect Transistor Characteristics Trainer , Resistance-Capacitance Coupled Amplifier Trainer , Metal Wire Coil (Experimental Use) , Stop Clock (Laboratory Model) , Mechanical Stopwatch , Digital Stopwatch , Measuring Tape (3 Metre) , Digital Screw Gauge , Digital Vernier Caliper , Meter Scale , Spirit Level , Slotted Weights With Hanger (500 G) , Slotted Weights With Hanger (100 G) , Slotted Weights With Hanger (50 G) , Tuning Fork , Measuring Cylinder (500 Ml) , Beaker (500 Ml) , Pinch Cork , Pair Of Bar Magnets (75 Mm) , Reading Lens With Torch , Plier And Cutter Set , Pellet Press Die (Potassium Bromide Die Set) , Laboratory Hardware Tool Kit , Vertical Laminar Air Flow , Celestron Lcd Digital Microscope (Model: 44341)Dimensions: 225 × 150 × 370 Mm , Double Distillation Plant (70 Lph) , Sony Ilce-Alpha 7Rms Mirrorless Full Frame Camera , Ph Meter Microprocessor Based Ph/Temperature /Mv Meter (Model: Eea-49) , Roll Cut Flower Cutter , Annual Rate Contract Auxano Meter (Small) , Taylor Soil Testing Thermometer , Willmotts Bubbler : Transparent Conical Wilmotts Bubbler Borosilicate Glass , Herbarium Sheets With Labels For Plant Specimens And Projects (A3 , Biology Dissection Kit 19 Piece , Borosilicate Glass Ganongs Respirometer With Stand , Ganong Potometer Borosilicate Glass Ideal For Plant Physiology And Transpiration Studies Accurate Measurement Tool For Laboratory , Khurpi: 3 Inch Pack Of 2 , Wet &; Dry Bulb Thermometer , Herbarium Plant Press 35X24cm With Screws And Tightening Nuts, Cork Sheets Inside For Pressing And Drying Plant Specimen , Specimen Jar With Knobbed Stopper. One Unit.20 X 10 Cm , Adtala 3 Led Light Handheld Magnifier , Poly Propylene Squeeze Water Bottle For Laboratory 500Ml (Wash Bottle) (Pack Of 2 Pieces) , Themisto 5 In 1 Satinless Steel Tweezer Set , Gubb All Purpose Large Scissor
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
24.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
25.
Defence #9528620 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date: Feb 11, 2026 Contract Value : 59.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
26.
Housing Urban and Rular Development #9468312 Technical Bid
Tender For Providing Rates For Supply/Fixing Of Various Items As Per Bill Of Quantity For Meerut Mandal - The Makrana First Class Marble work for cladding will use 40mm thick slabs of premium Makrana marble, known for its uniform shade, minimal veining, and absence of surface defects. The backing for this marble cladding will be filled with a 12mm thick layer of cement mortar, mixed in a ratio of 1:3 (1 part cement to 3 parts coarse sand). The marble will be secured to the backing using stainless steel cramps or any other approved fixing system, which will be paid for separately. For joint treatment, pointing will be done using white cement mortar mixed with marble dust in a ratio of 1:2 (1 part white cement to 2 parts marble dust), with an admixture of pigment to match the marble’s shade, ensuring uniformity in appearance. After installation, the marble surface will undergo mirror polishing using mechanical equipment to achieve a high-gloss, scratch-free finish. 2 Classic decor POLE LIGHTS with customise bracket Supply ,Installation ,Testing And Commissining OfHybrid Decorative Pole Dragon-H Pole iwth height of 7-9M With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Valmont-/-Havells/Neri/Juvaas/Orient/ Thor) 3 3-Dimensional Statue Ornamentation Work : supply, fabrication, transportation, hoisting, and installation of high-quality 3-Dimensional marble statues across various elements at all levels. The stone used must be free from cracks, lines, stains, and exhibit uniform shading throughout. It shall be fine-grained, with a reddish or buff color (locally sourced). The work is to be executed in strict accordance with the attached drawings, incorporating processes such as manual or machine carving, ornamental detailing, traditional motifs, figure work (of any type and size), CNC cutting, and molding. All carving and molding shall be of the highest quality. The installation of the stonework must be precise, ensuring that all elements are aligned, leveled, and plumb, and fixed using brass clamps, pins (to be paid for separately), dowels, cement slurry with matching pigments, and epoxy adhesives of approved brands such as Akemi Germany, Ardex Endura, or MYK Laticrete, as specified and approved by the Architects 4 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamentalsandstone statue in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 1.5MX1.5MX1.5 Mtentative Size as approved from architect in charge 5 2-dimensional Ornamentation Work :- Supplying, fabricating, transporting, hoisting, and fixing in position good quality marble for various elements at all levels. The stone shall be free from cracks, lines, stains, and shall have an even shade for each element. The stone shall be fine-grained and reddish or buff-colored (locally available). The work shall be carried out as per the attached drawings, involving different processes such as carving (manual or by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, and molding. The carving and molding work shall be of very good quality. The stones are to be fixed in line, level, and plumb in all respects using brass clamps, pins (to be paid for separately), dowels, cement slurry with matching pigment, and Epoxy of Akemi Germany, Ardex Endura, MYK Laticrete, or other approved brands as required and as approved by the Architects. 6 Supply, Installation, Testing & Commissioning of 16mm X 16mm of 5 meters length RGBW Neon Flexible stripled light with Non- Integral driver embedded inside. The luminaire’s shall be made of Silicon extrusion with high-efficiency, high grade appearance, soft bend flexibility & Option of Top bend , the same shall be so designed with completely made in India luminaire.The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP67 protection. Required external decoder. The LEDs shall have minimum CRI ≥80 (White Light). The luminaire shall have system wattage of 14 Watt/ meter. Fixture shall operating temperature range of 0°C to 45°C. The fixture shall have an Non integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 6-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report of the family of luminaire issued by NABL accredited lab, LM80 issued by LED manufacturerBIS certificate for LED Luminaire.. Brand name shall be embossed / printed on each an every light fixtures. (Wipro/Trilux/Colour Kinetics) 7 POLE LIGHTS Supply ,Installation ,Testing And Commissining OfTwinkle Lites Make 3000Mm Long Hybrid Decorative Pole With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Twinkle Lite-/-Havells/Neri/Juvaas/Orient/ Thor) 8 Supply, Installation, Testing & Commissioning of 196mm Dia X 158mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 60W and shall deliver 3300 lumens. Beam angle of the Luminaire shall be 15 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. (Wipro/Trilux/Colour Kinetics) 9 Supplying, fabricating, transporting, hoisting, and fixing in position high-quality modular size wire-cut bricks for various elements at all levels. The bricks shall be free from cracks, lines, stains, and even in shade for each element, ensuring uniformity. The bricks shall be fine-grained and of a reddish or buff color, sourced locally. The work shall be executed as per the attached drawings, incorporating various processes such as carving (manual or by machine), ornamental work, traditional work, figure work (of any type and size), CNC cutting, and molding. The carving and molding work shall be of excellent quality, finished with a water-repellent coating from an approved manufacturer, as required and as approved by the architects. 10 Supply, Installation, Testing & Commissioning of 1000 mm length X 80mm Width X 115mm Height RGBW Linear Wall Washer with Non-integral driver & completely made in India luminaire. Luminaire must use Double LED Array of RGBW Chip Double Array and not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK07 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 96W and shall deliver 3840 lumens. Beam angle of the Luminaire shall be Assy. deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 11 Supplying, fabricating, transporting, hoisting, and fixing in position high-quality modular size wire-cut bricks for various elements at all levels. The bricks shall be free from cracks, lines, stains, and even in shade for each element, ensuring uniformity. The bricks shall be fine-grained and of a reddish or buff color, sourced locally. The work shall be executed as per the attached drawings, incorporating various processes such as carving (manual or by machine), ornamental work, traditional work, figure work (of any type and size), CNC cutting, and molding. The carving and molding work shall be of excellent quality, finished with a water-repellent coating from an approved manufacturer, as required and as approved by the architects. 12 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamental red sandstone Jharokha in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 0.5MX0.3MX0.75Mtentative Size as approved from architect in charge 13 Supply, Installation, Testing & Commissioning of 196mm Dia X 158mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 60W and shall deliver 3300 lumens. Beam angle of the Luminaire shall be 30deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 14 Supply, Installation, Testing & Commissioning of 148mm Dia X 149mm Height RGBW Circular Flood light with Non-integral driver & completely made in India luminaire. Luminaire must use Single LED of RGBW ChIPand not descrete individual LEDs of each colour for colour effect. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 36W and shall deliver1980 lumens. Beam angle of the Luminaire shall be 15 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC, Integrated DMX Decoder,No need to additional external decoder. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall be compatible with DMX controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make.(Wipro/Trilux/Colour Kinetics) 15 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamentalsandstone statue in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 1.2MX0.6MX0.6 Mtentative Size as approved from architect in charge 16 Providing and fixing archeton terracotta cladding of U-Value 0.8 & R value of 1.25 and dimension 304*594*16 mm with modules of 300*600 with Q3** resistance to impacts (classification as per French standards) with wind resistance to positive/ negative pressure 6500 / 4500 Pa, weight of27.13 kg per m2 which conform to standard NF EN 539-2, water absorption to be between 3% - 5% conforming to EN ISO 10545-3 § 5.1.1, bending strength not to exceed 1400 Newton conforming to EN ISO 10545-4. Installation of terracotta panels to be done by securing to the vertical T-shaped aluminium profile using the fixing clips fastened with 2 self-tapping stainless steel screws. Vertical aluminium T-shaped profiles are to be pre-punched hole with vertical spacing of 25mm. The terracotta tile is to be well-supported on four points by the clips and on its two smaller sides by the rubber gasket so as to have a very good wind load resistance of more than 6500 PA positive wind load pressure and a negative wind load pressure of 4500 PA and flexural strength of 135 da N. The total thickness cladding system is not to be more than 110 mm.The quantity of products per sq.m are to be 5.56 tiles, with quantity of profiles per main course sq.m to be 1.67 lm/m2, with quantity of clips to be 11.11 nos. per sq.m . Scaffolding and electricity for fixing to be provided by GC Make -Archeton 17 LEDmodules are engineered accordingly to the existing regulations of LumenMaintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surgeprotection 6KV. Product as per KLiTE KL4636. The manufacturer should have inhouse manufacturing facility and inhouse goniophotometer to check the photometry of the LuminaireSITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 1800 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 655 (L) x 400 (W) x42 (H), Battery Capacity max. 15 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-4000-6000k, Make-Valmont,Panasonic, Philips or equivalent 18 Supply of exterior rated Architectural RGBW Linear LED Wall Washer luminaire; suitable for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, Total System wattage not exceeding 40W with system lumen output should be more than 1500 lm with all LEDs on. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 125.5 mm ± 5% including surface mount basewidth 64 mm ± 5% , length 1200 mm ± 5% with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire should be 230Vac, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305VAC, PF > 0.90 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be > 80,000hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc > 90°C. Fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 19 Bollards Supply And Fixing Of Twinkle Lites Make Tigris 800Mm Long Made Out Of Extruded Aluminium Profile With Cast Alumn Base With 18W Led. (Make- Twinkle Lite-Equvalent In :-Havells/Neri/Juvaas/Orient/ Thor) 20 Supply, Installation, Testing and commissioning of DMX Master Controller, with completely made in India product. A stand alone interface for installation in electrical DIN Cabinets with Din rails, which can control from 512 to 1024 and can go up to 2048 channels on 1, 2 or 4 DMX universes. A robust Stand Alone mode and a wide range of trigger possibilities (RS232, Contacts, Clock, NODE x4 ports, Master/slave), USB-C Networks Ethernet, Internet, WIFI compatible when connected to a router Multiple Zone 10 Zone, play 10 scene/sequence per time in Stand Alone ,Memory of Micro SD Card ( max. 256 GB ) and 8Mb Internal memory . Art-Net and sACN from SD card, including triggers (2x512). A master / Save Synchro (32 max wired / 128 max Ethernet) that Commands from the Contacts (speed, scene, dimmer, zone). Default start scene, Scene priority, Cross Fade time between scenes , Automatic Scene Recovery if the power is cut off and 16-bit and fine channel management. Triggers options of RS232 In/Out (16 characters max for RS232 triggers, commands or orders) and UDP / Ethernet triggers and commands (from SDK). Software Requirements with System Compatibility of Windows, Mac, iOS. Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100—240VAC,Minimum five configurable effects, Using light show authoring software to select from standard five effects, adjust effect settings such as color, speed, and brightness. IP20. Addressing & Programming inclusive and with Five Year Warranty. Brand name shall be embossed on each and every lighting fixtures.(Wipro/Trilux/Colour Kinetics) 21 Supply of 4 Meter height Carley Square 40W LED in Extruded aluminium bottom pipe (grade 6063 with test certificate) Sq. 150 x 3mm thickness, extruded aluminium stem with inner ribbed Sq.30 x 2mm thickness, extruded aluminium top pipe with inner ribbed with Light Distribution 360°. Pre treated with silicone gaskets. PDC aluminium service door 330mm height x 75mm width at 335mm height above the base plate shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. For better lighting performance there is Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed is position. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >87%, power factor >0.95, IP65, THD <10%, Surge protection 5KV. LED Colour Temperature 3000K, 230-240Vac, CRI >80, MacAdam step> 3, Mechanical resistance IK08. MS mounting plate Sq. 250 x 12mm thick steel of grade E250 to IS 2062:2011 with 4 elongated holes 38 x 19 to suit M16 bolts at CC180. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation pole. Hot dip galvanised foundation bolt. The pole should undergone Pure polyester powder coated process, Mild shot blasting. The product should be BIS and CE Certified. Make as per Klite KL-4663/Unilamp/Ligman. 22 Supply, Installation, Testing and commissioning of DMX Decoder completely made in India product .Input Power DC 12V -24V input which Outputs 6A/Channels. 100-240V, 24VDC plug-in power adaptor .The number of devices controlled from 001-512 via DIP Switch. Connection of DMX (3 pin, 3.5mm pitch screw terminal). Channel bondin capable up to 10A. 8 pin terminal connector current LED connection. Compact PCB or chassis mounted.All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter+Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Protection of short circuit, Reverse Polarity, Over Temprature, Over Voltage and Over Current. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. 23 Supply, installation, testing & commissioning of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe,2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universeshould be expandable from 2 to 4 DMX512 universes.It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet .Dmx controller should have network controllabilityfeature to control the scene remotely through LAN and triggered via UDP packets on port 2430.Its must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should haveIntuitive backlit keyboard with 10 presets and also have provision of kepad on devicefor changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. weight should not be more than 120g. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. All Dynamic LED lighting fixtures & controllers shall be of same make to avoid integration, synchronization, and maintenance issues in future. To be provided with IP 66 enclosure if installed in external environment & shall be provided with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 24 Supply of Isolated, constant Voltage type240 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP 66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 150V to 270V (nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. 25 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 300 wide average.Depth 45 cm with R.C.C. slab 26 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 27 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 28 Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work completeDomestic Water Supply pumps :Capacity/Flow Rate - 12.5 m3/hrHead- 45 mLocation-1 set in UGT (1 set = 2nos(1W+1S)) 29 Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work completeDomestic Water Supply pumps :Capacity/Flow Rate - 12.5 m3/hrHead- 45 mLocation-1 set in UGT (1 set = 2nos(1W+1S)) 30 Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent) 31 Providing and laying 80 mm thick machine cutcement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 32 Supply and Fixing of KL-4098 Inground Luminare of 8W LED Asymmetrical (DIA.116 X153)MM Supply of 3000K/4000K/5700K In-ground 8W asymmetrical luminaire made up of die-casting with Ø116 stainless steel 316 gradefront ring with silicone black gasket and toughened clear glass diffuser. With Electronic Driver, The luminous flux of the luminaire is upto 550 lm for 3000K BA- 35°/45° (Asy). The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power NICHIA LED with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs at L70B10. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 3KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100- 277Vac and operating temperature of -20˚ ~ +40˚C with CE confirmed BIS approved. There may be changes in fixture selection and quantity as per architect intent Make: K-Lite KL-4098, Unilamp/ Ligman 33 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall Ground Floor 34 Supply of Isolated, constant Voltage type150 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP 66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 150V to 270V (nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. 35 Supply, installation, testing and Commissioning of 5Core 5C DMX cable/Patch cord Patch Endcap 1m 36 Supply of exterior rated Architectural LED RGB flood lighting luminaire; suitable for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, Total System wattage not exceeding 40W withsystem lumen output should be more than 2000 lm with all LEDs on. Luminaire shall be capable of producing dynamic color changing lightwith 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 66 mm±1% including surface mount base , Length of282 mm±1% and Width of 274mm±1% with constant locking hinges for simple position control from various angles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. DMX enabler circuit should be inside the Luminaire only.. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 37 Providing and fixing of outdoor fixed stone bollard of size 300X1000m, finish: sanded with a polished effect inlcuding rate ofengraving and illustrations as per architect incharge 38 Supply, Installation, testing and commissioining of TruAudio AS-1 AcoustiScape 4.5Outdoor Landscape Speaker Make: Bose/ L-Acoustic/ Powersoft 39 Planning, Designing, Programming of all the light fixtures with integration into controller and making multiple programming in total of 5 different occasion. Synchronizing all fixtures into one. 40 SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent 41 Supply, Installation, Testing and commissioning of DMX Splitter, Booster 343 mmHeight X 123mm Width X 46 mm Depth with completely made in India product .Input Power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included Power Consumption 4.5W max and of MS/ Aluminium Housing. Power Consumption of 4.5 Approx and Weight of 1.5Kg .The output terminals should be optically isolated from the input and share a common ground reference. All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter+Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. (Wipro/Trilux/Colour Kinetics) 42 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector L.T. Switch Panel Board :switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypeLighting Panel :Incoming -100 Amp MCCB - 1 No.Outgoing - 40 Amp DP MCCB - 4 No. (for d.b. )32 Amp 4P MCCB - 2 No. (for Spare)(Complete as per requirment directed by Project Manager.)Armoured Cables (Cable/Gland/Lug) : 43 FREE STANDING WALL CLADDING 44 Providing and laying 80 mm thick machine cutcement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 45 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 46 Supply, Installation, Testing and Commissioning of Feeder Panel - 5 KVA 3 Phase along with01 No. UPS to provide safety / good quality power supply to DMX Controller. 47 Supply and Installation of Circular pendant Luminaire 36W with IP65 and mechanical resistance IK07 Luminaire made of extruded aluminium alloy (grade 6063) of high corrosion resistance with translucent Diffuser Material of Clear PMMA extruded lens. Luminaire should be with Standard suspension kit of 1M. Protection class IP44. The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 120° for uniform lighting effect. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-3232/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified. 48 Supply of linear 3000K/4000K/5700K In-Ground Grazer 24Vdc CRI >90 MacAdam step 3 Input power : 12WLight Distribution should be Symmetrical Electronic driver ON/OFF (External driver) CE and BIS Approved. LUMINAIRE TYPE: Facade encapsulated3000K/4000K/5700K In-Ground Graze with IP67. MATERIAL CHARACTERISTICS should be High grade aluminium housing (grade 6063 with test certificate) with End cap, SS fasteners & Clip, Mechanical resistance IK07. LIGHTING PERFORMANCE:: Polyurethane Encapsulation clear diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum(TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV. Including required accessories There may be changes in fixture selection and quantity as per architect intent Make Klite KL-3277,Unilamp/Ligman 49 Supply and fixing of TG RO43 BETA, powder coated Tree guard as per design approved by Architect in charge with the following specifications:The unit is in powder form, packed in a 5Kg drum for secure handling and transportation. The product features a cylindrical design made of mild steel, with a color-coated green finish for durability and corrosion resistance. It has an opening size of 2 inches, a mesh number size of 11-50, and measures 5 feet in height.The structure includes 3 legs with 4 ties for enhanced stability during use. Weighing 3.5 kg, the item is lightweight yet sturdy, ensuring easy handling and installation. It is made from galvanized material, adding to its longevity and resistance to environmental factors. 50 Supply and Fixing of KL-3594 Aster-6 of 20W LED(2010X13X5.4)MM Supply of 20W Monocolour encapsulated flexible LED Strip having Dimension 2010 x 13 x 5.4 with IP 67, 3000K/4000K/5700K, 24Vdc CRI >80 MacAdam step>3, Beam angle : 120°, Should be equipped with dot less homogenous lighting effect, Electronic driver ON/OFF (External driver), MATERIAL CHARACTERISTICS, High-Grade Horizontal bend Elasto Polymer & Endcaps, Silicone moulded diffuser, End Cap, This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. The OEM should have in house facility of encapsulation and in house testing laboratory. Certification: CE Certified, BIS Certification for Luminaires. Make as per Klite KL-3594/Unilamp/Ligman, 51 Supply and Fixing of integral 50W Post Top Dynasty Luminaire with ColourTemperature 3000K/4000K/5700K with luminous flux : 6128 / 5900 / 6224 lmrespectively, Maximum Voltage- 240 AVC CRI >80 MacAdam step 3 and LightDistribution 360° with CE and BIS certified IP 65 and IK09 Make in India Productwith having material characteristic Body : Die Cast Aluminum top cover withClear Polycarbonate Optical Lens, Mounting : Suitable for Ø60mm OD Pipe, Finish: Powder Coated Graphite Grey / Jet Black Anthracite and decorative knob onbottom, Gravity die cast aluminum (LM6 Grade) supporting arm integrated with die-cast aluminum base. SS fasteners with Pure polyester powder coated process& Acid treatment & pure polyester powder coating. For better lightingperformance Translucent acrylic diffuser of 2.7mm thickness with controlleddownward light emission, the translucent acrylic diffuser formed from nonyellowing acrylic sheet with lamp fixed position. Dimension of the Luminaireshould be Sq.325 x 560mm . This luminaire contains built-in LED modules. 52 Supply, Installation, Test in gand Commissioning of LEDRGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be amangle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at anambient temperature range of-10°Cto +50° C and shall be IP65 and IK06 rated. Life time shall be atleast L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS(IS10322) and shall be complete with all necessary accessories required for proper working of fixture in cluding weatherproof connection cables, waterproof connector setc. as required. 30 W 53 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 54 Supply of Spike light luminaire LED 3000K/4000K/5700K 240Vac CRI >80 Mac-Adam step 3, Input power 6W having Dimension 101 x Ø90 x 330 mm, Beam Angle : 40° with Electronic driver ON/OFF. CE and BIS Certified. LUMINAIRE TYPE Spike Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS Die-Cast aluminium housing & Front ring (grade ADC12 with testcertificate). Surface mounting spike made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly tothe existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40ーC. Operating ambient temperature range is from -15ーC to +50ーC. Driver efficiency >84%, power factor >0.95, THD <10%, Surge protection 2.5KV. There may be changes in fixture selection and quantity as per architect intent. Make: K-Lite KL- 4265/Unilamp/Ligman 55 Supply and fixing of Tri Arc Terracotta Pavers: robust and aesthetic applications, having 3.5 tiles per square foot for coverage; tile weighs approximately 2 kg having terracotta finish as approved by Architect in charge make: Nuvocotto/or equivalent; thickness of 60 mm, ensuring durability and resistance to wear and tear. They are ideal for outdoor and heavy-traffic areas, providing both functionality and visual appeal.The scope of work includes delivering the pavers to the site and ensuring proper installation as per best practices. This involves preparing the base, aligning the tiles accurately, and securing them in place to achieve a durable and visually pleasing finish. 56 Bollard Light :Supply and fixing of LED Bollard robustly designed IP65/IK10 Bollard is easy to install with base plate(BCP150 LED /NWPSU 220-240V 7043)(K-litePhilips/Panasonic/Havells or Equivalent) 57 Supply, Installation, testing and commissioining of LSZH Speaker Cable 2C/14 AWG 2.5Sq.mm. Jkt Purple 152M Make: Bose/ L-Acoustic/ Powersoft 58 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 59 Supply, installation, testing and Commissioning of 5Core T Type 5C DMX cable 60 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 300 sq.mm. 61 Supply of 3000K/4000K/5700K In-ground 8W asymmetrical luminaire made up of die-casting with Ø116 stainless steel 316 grade front ring with silicone black gasket and toughened clear glass diffuser. With Electronic Driver, The luminous flux of the luminaire is upto 550 lm for 3000K BA- 35°/45° (Asy). The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power NICHIA LED with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs at L70B10. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 3KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100- 277Vac and operating temperature of -20˚ ~ +40˚C with CE confirmed BIS approved. There may be changes in fixture selection and quantity as per architect intent Make: K-Lite KL-4098, Unilamp/ Ligman 62 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of OLDEST BANYAN TREE NARORA, BULANDSHAHR,or as approved by Client department having Helvetica Font with 400mm size Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 63 Supply and fixing of Tri Arc Terracotta Pavers: robust and aesthetic applications, having 3.5 tiles per square foot for coverage; tile weighs approximately 2 kg having terracotta finish as approved by Architect in charge make: Nuvocotto/or equivalent; thickness of 60 mm, ensuring durability and resistance to wear and tear. They are ideal for outdoor and heavy-traffic areas, providing both functionality and visual appeal.The scope of work includes delivering the pavers to the site and ensuring proper installation as per best practices. This involves preparing the base, aligning the tiles accurately, and securing them in place to achieve a durable and visually pleasing finish. 64 Supply, Installation, testing and commissioining of Yamaha PX3 Power Amplifier Make: Bose/ L-Acoustic/ Powersoft 65 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 10 sq mm x 4 core 66 12 mm Brick tile work for wall lining over required bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sqm including pointing in white cement complete. 67 supply and fixing following capacity of automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc.complete in all respect. 40 A SPN 68 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 69 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 70 Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. 71 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 72 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.FEEDER PANEL -1Incoming :One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity Bus Bar :One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.40 Amps DP MCB of 10KA - 2 No16 Amps DP MCB of 10KA - 12 No2 No. SPACE & SPAREPanel described as above 73 Supply and Fixing of Spike Light for trees 12 watt Warm White. (Including civil works) 74 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 75 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 76 Supply of 125 mm dia MSpipe as per IS1239 77 Supply and Installation of Cylin 30W ceiling mounted compact downlight. Type IV Medium light distribution. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Polycarbonate optical lens for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Make as per KL-3629/ Ligman/ Unilamp. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 166mm diameter x 160mm height. CE & BIS Certified. 78 Supply of 125 mm dia MSpipe as per IS1239 79 Supply & fixing Ornamental clay tiles of 10X16 inches for ceiling including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. 80 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 81 Supply installation commissioning of following sizes of power and data cable as mentioned:3C x 4 sqmm Cu unarmored multistrand 82 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( FOR EXTERNAL) 83 Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( FOR EXTERNAL) 84 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge 85 Supply, installation, testing and Commissioning of 2Core 2C DMX cable/Patch cord Patch Endcap 1m 86 Transport of boring tools other required equipements and installation at site. 87 Supply and Installation of 3000K/ 4000K/ 5700K Sill Luminaire with maximum wattage 6W made of Die cast aluminium housing with SS fasteners. Pre treated with silicone gaskets and provided with Die-cast aluminium mounting plate with pure polyester powder coating. Mechanical resistance IK08. The luminaire shpuld undergone Acid treatment & pure polyester powder coating. For LIGHTING PERFORMANCE Optical grade clear polycarbonate lens is provided and Lamp in fixed position. This luminaire contains built-in LED modules. Dimension of the luminaire should be maximum 150mm x 90mm x 43mm. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. IP rating of the product will be IP65. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >70%, power factor >0.95, THD <10%, Surge protection 2.5KV. Make as per KL-3078/ Ligman/ Unilamp. CE & BIS Certified. 88 Transport of boring tools other required equipements and installation at site. 89 Supply and fixing of TG RO43 BETA, powder coated Tree guard as per design approved by Architect in charge with the following specifications:The unit is in powder form, packed in a 5Kg drum for secure handling and transportation. The product features a cylindrical design made of mild steel, with a color-coated green finish for durability and corrosion resistance. It has an opening size of 2 inches, a mesh number size of 11-50, and measures 5 feet in height.The structure includes 3 legs with 4 ties for enhanced stability during use. Weighing 3.5 kg, the item is lightweight yet sturdy, ensuring easy handling and installation. It is made from galvanized material, adding to its longevity and resistance to environmental factors. 90 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall Ground Floor 91 FEEDER PANEL -2Incoming :One (1) No 40 Amp. 4P MCCB of 25KABreaking capacity Bus Bar :One (1) No. 63 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.16 Amps DP MCB of 10KA - 8 No2 No. SPACE & SPAREPanel described as above 92 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of 500 YEAR OLD BANYAN TREE ,having Helvetica Font with 300mm size Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 93 Supply and laying with 32MM GI pipe ISI DSR SI 2831 as per site requirement 94 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 50 sq mm x 3-1/2core 95 Providing and injecting HM-500 Epoxy Anchoring Type: HM-500 : Red or Black Density: 1.5±0.1g/cm³ in proportion Mix Ratio: 3:1 Color/ or recommended by the manufacturer into drills cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (make Hilti/HM or equivalent) 96 Supply and Installation of 30W Extruded aluminium Luminaire with Tree Strap. Module fixing clamp made of galvanized CRCA sheet 3mm thickness. SS fasteners. IP Rating should be IP65 with different beam angles as per the requirement 10° / 28° / 45°. Clear silicone gaskets. Die-cast aluminium mounting plate Ø100.5 x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 with pure polyester powder coating. Mechanical resistance IK07. The luminaire should have undergone Acid treatment & pure polyester powder coating. For better LIGHTING PERFORMANCE Clear polycarbonate optical cover with light emission at desired angle. Lamp fixed position. Colour Temperature should be as per 3000K, 4000K, 5700K 230-240Vac CRI >80 MacAdam step 3. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.95, THD <10%, Surge protection 4KV. Make as per KL-4286 with Kl-8275/ Ligman/ Unilamp. CE & BIS Certified. 97 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver with theft protection set complete in all respect. 98 Supply of Surface mounted spot light LED 3000K/4000K/5700K 240Vac CRI >80 MacAdam step 3 Input power : 10W Dimension Ø95 x 124 mm, Beam Angle : 40° without Electronic driver ON/OFF, LUMINAIRE TYPE : Wall Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS: Die-Cast aluminium housing & Front ring (grade ADC12 with test certificate). Surface mounting Bracket made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE: Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40ーC. Operating ambient temperature range is from -15ーC to +50ーC. Driver efficiency >84%, power factor >0.95, THD <15%, Surge protection 2.5KV. Make: K-Lite Model no.-KL-4245/Unilamp/Ligman 99 Supply and Installation of Wall-mounted 6W compact wall quad down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) 100 x 3mm thickness, die-cast aluminium glass fixing frame 100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outer corner siliconed to frame & die-cast aluminium top closing frame ?100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. Make as per Kl-3635/ Ligman/ Unilamp. The luminaires built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. 100 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 101 Drilling of 200 mm dia bore hole. 102 Drilling of 200 mm dia bore hole. 103 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 240 sq.mm. 104 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 6 sq mm x 2 core 105 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 106 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 35 sq.mm 107 Supply and Fixing of Spike Light for trees 12 watt Warm White. (Including civil works) 108 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 109 Supply of Zedo Round Surface Mounting Light 110 Supply, installation, testing & commissioning of DMX Signal Amplifier to boost the Signal, IP 65 rated module to enahce the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic ciruit for functioning. 111 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 112 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm 113 Supply of 125 mm dia slotted MSpipe 114 Supply and Installation of Adjustable 12W Trisha round luminaire Ceiling-mounted recess down light. Beam angle 15° / 25° / 38°/ 60°. Die-cast aluminium housing with heat sink for excellent thermal management. Metallized thermoplastic reflector with anti-scratch protection treatment with high luminous efficiency and visual comfort. Protection class IP20. Powder coated white. Available colour temperature WW / NW, Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-8178 with KL-7081/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >87%, Power factor >0.95, THD< 10%, Surge protection 3KV. Luminaire dimension : 80mm diameter x 104mm height. C.O.D : 50mm diameter. BIS & CE Certified. 115 Supply of 125 mm dia slotted MSpipe 116 Supply of RADO MINI Wall light 117 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 118 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 119 Providing & fixing White River (Stone) Pebbles size of 2 to 2.5 dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. 120 12 mm Brick tile work for wall lining over required bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sqm including pointing in white cement complete. 121 Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 350 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 122 Supply & Installation Of-UNICOPro Welded Mesh Modular FenceSystem.Panel: Galvanised MS Wires.Post: Galvanised MS.Panel Height: 1560 mm.Panel Width: 2500 mm.Mesh Aperture: 50 mm x 200 mm.Wire Diameter: H-4.5 mm, V-4.5 mm.Post Type: H-Profile.Post Height: 1600 mm.Mounting Type: Base Plate.Surface Finish: Pure PolyesterCoating/Over 65 Microns/1000 HoursSalt Spray Tested.Colour Code: RAL 6005 (Moss Green). 123 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 25 sq.mm. 124 Supply and Installation of 1.5 HP Submersible pump set complete 125 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) 126 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 127 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 128 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 50 sq.mm 129 Electric logging of bore hole 130 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 131 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 132 Providing and fixing ISI marked S.S. Tower bolts black finish, (Barrel Type) with necessaryscrews etc. complete(a) 250 mm x 10mm 133 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN 134 Providing and fixing 12 mm thick frameless toughened glass of approved brand and manufacture, includingnecessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 137 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 138 Providing and fixing ISI marked S.S. Sliding door bolts with nuts and screws etc. complete(a) 300 mm x 16mm 139 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 140 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 141 Providing and fixing ISI marked S.S. handles conforming to IS 4992 with necessary screws etc. complete.125mm 142 Providing and packing of coarse sand / pea gravel around the pipe. 143 Supply and laying of Chetan 1.5 Mtr RCA Male to XLR MaleCable Make: Bose/ L-Acoustic/ Powersoft 144 Providing and packing of coarse sand / pea gravel around the pipe. 145 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm (Toilet & Kitchen) 146 Supply & fixing of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 147 Supply and Fixing Mirror Light(Philips/Siems/or Equivalent) 148 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 149 Supply and fixing of nylon jali around the slotted pipes complete as required. 150 Testing and development of tube well. 151 Supply and fixing of nylon jali around the slotted pipes complete as required. 152 Testing and development of tube well. 153 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 154 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 155 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 156 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 157 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 158 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 159 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 160 Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 350 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 161 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 10 sq mm x 4 core 162 Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:-Lehry Make Level Float Switch1) Body: Polypropylene, Highly Durable, Water Proof2) Rating : IP683) Temperature : 0-50DegC 4) Cable : PVCSize 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) 163 Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:-Lehry Make Level Float Switch1) Body: Polypropylene, Highly Durable, Water Proof2) Rating : IP683) Temperature : 0-50DegC 4) Cable : PVCSize 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) 164 Supply and fixing of LED 18w Round Sky Glow Next Gen LED Downlight fitting 18 watt suitable with complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 165 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 10 sq mm 166 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 167 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 6 sq mm 168 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 6 sq mm x 2 core 169 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 1473110 mm size 170 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 171 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 172 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 90 mm size 173 Design & Fabricating Ornamental work on mild steel (MS) sheets, which includes a series of detailed processes to achieve the desired design and finish through CNC cutting, which allows for precise and intricate patterns to be cut into the MS sheet based on the approved drawings and designs provided by the Architect in charge. Following the cutting process, etching and engraving are performed to add depth and detail to the design, enhancing the ornamental appearance. These processes involve carefully removing material from the surface to create the desired patterns and textures. After the cutting, etching, and engraving are completed, refilling is conducted to ensure the engraved areas are smooth and consistent with the overall design. This step ensures that the intricate details are highlighted and any imperfections are corrected. The MS sheet used for this work will be of an approved thickness to ensure structural integrity and durability. Additionally, the specification includes the cost of powder coating the MS sheet in an approved shade.(make Metaguise/Citadel/ Woodform Architectural or equivalent) 174 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735110x110x110 mm size 175 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 1473590x90x90 mm size 176 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735110 mm size 177 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 1473590 mm size 178 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735110 mm size 179 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 90 mm size 180 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 50 sq mm x 3-1/2core 181 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 50 sq mm 182 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735110 mm size 183 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 6 sq mm x2 core 184 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 1473590 mm size 185 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 25 sq mm 186 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cablesize 6 sq mm x2 core 187 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesqmm 6.00 188 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 189 Controllers for above RGBW Luminiaries 190 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm 191 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3 x 6 sq.mm, 192 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 450 wide average.Depth 60 cm with R.C.C. slab 193 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 600 wide average.Depth 90 cm with R.C.C. slab 194 Supply and Installation of 3W Static White 3000K Sudo Step Light, Should be rectangular compact and robust wall recessed luminaires for illuminating walls and stairs. Must be forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class at least IP65 or higher. Mechanical resistance IK09. Pure polyester powder coated graphite grey / anthracite grey / jet black should be available in different colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire installation in a recessed opening cut-out dimension : C.O.D : 70mm length x 83mm width x 124mm height. Make should be as per KL-2761/ Ligman/ Unilamp. CE & BIS Certified. 195 Supply and Installation of Mini Wall Grazer upto 30W K-Lite compact and minimilist linear surface mounted designed for wall wash effect. Luminaire made of extruded aluminium alloy (grade 6063) of high corrosion resistance with translucent end caps. Diffuser Material of Clear PMMA extruded lens. Protection class IP44 and mechanical resistance IK07. Luminaire should be Powder coated white / grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 30°. 60°. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Make should be as per KL-2830/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : 1520mm length x 21mm width x 26mm height. CE & BIS Certified. 196 Supply and Installation of track lightofDie Cast Aluminium & Plastic with translucent Diffuser Material of Clear PMMA extruded lens.of size 2.5 x 5.0 x 17.2 cm / 14.5 x 6.0 x 20.0 cm / 18.0 x 8.0 x 21.0 cm Luminaire should be with Standard suspension kit of 1M. Protection class IP20 . The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. High efficacy leading to energy conservation.Available colour temperature 2700K / 3000K / 4000K / 5700K, Beam Angle should be 120° for uniform lighting effect. Colour rendering index (CRI)>80. SDCM ≤ 3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Make should be as per Tisva/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 220 V AC – 240 V AC / 50 Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified. 197 Supply and Installation of track accessories of length 2M of Die Cast Aluminium & Plastic with translucent Diffuser Material of Clear PMMA extruded lens.of size 2.5 x 5.0 x 17.2 cm / 14.5 x 6.0 x 20.0 cm / 18.0 x 8.0 x 21.0 cm Luminaire should be with Standard suspension kit of 1M. Protection class IP20 . Extruded aluminium tracks with full set of accesories for creative, flexible, reliable and precise installation. The driver should be inbuilt with the luminaire. Luminaire should be Powder coated white / grey. Make should be as per Tisva/ Ligman/ Unilamp. Prewired with LED driver and suitable for operating on 220 V AC – 240 V AC / 50 Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection upto 3KV. Luminaire dimension : Ø900mm dia and 25mm height. CE & BIS Certified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
27.
Public Administrative Department #9463829 Technical Bid
Tender for the remaining work (development work and electrification work) of Sanskriti School under construction under CG City Scheme, 1 ROAD WORK 2 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1 3 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD SOR 4 Providing and laying design mix cement concrete of M-30 grade, inroads/ taxi tracks/ runways, using cement content as per designmix, using coarse sand and graded stone aggregate of 40 mm nominalsize in appropriate proportions as per approved & specified designcriteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdyM.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints ( 10 mm wide x 50 mmdeep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction ofEngineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content in M-30 is @ 340 Kg/Cum. Excess/Less cement Used as per design mix is separately.DSR 16.43.2 5 Providing and fixing in position pre-moulded joint filler in expansion joints.DSR 16.45 6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD SOR 504 7 PARKING 8 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 9 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD 10 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2 11 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. DSR 16.63 12 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment. (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 13 DRAIN 14 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.DSR 2.8.1 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)DSR 4.1.8 16 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1 17 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD 504 18 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) DSR 13.7.1 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2 20 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1 21 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.DSR 23.9 22 COLUMN UPTO 10 FT 23 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6. 24 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level DSR 5.37.1 25 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 26 RETAINING WALL 27 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 28 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 29 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 30 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 31 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size). DSR4.1.6 32 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 33 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 5.9.2 34 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 35 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 36 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 37 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm DSR 22.23.2 39 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. DSR 22.1.1 40 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone DSR 22.2.1 41 SKYLIGHT & BRICK WORKS 42 Providing & fixing of roof with multilayer standing seam polycarbonate panel system of 18mm thickness (min) including all standard fixing accessories on top of the supporting structure (paid extra) complete & as per the direction of the engineer in charge. The panels should work on angular daylighting concept with translucent and opaque combination of louvers inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shading throughout the day for better ambient temperature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The entire panel system shall be with a width from min 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on purlin with snap on connectors with grip lock double tooth locking mechanism and will be secured on MS Structure/ purlins (will be paid separately) with HDSS Fastener and double tooth polycarbonate connector for best stability and having a pull-out load of min 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called X structure for better strength and stability. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycarbonate panel which have been exposed to UV for a min. of 500 hours as per ASTM G155. Panels shall not have yellowness Index as per ATSMD 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 2.0W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cp/ Aluminium U/F profile/ Glazing Bar (all mill finish) for ends as required. Trained and factory authorized layout with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge.Colour: as per approval. 43 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 44 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 45 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 46 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) DSR 13.5.2 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) DSR 13.46.1 49 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 50 CHAIN LINK FENCING 51 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 52 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 53 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 54 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 55 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1 56 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 57 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 58 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 59 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 60 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade DSR 16.70.2 61 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes DSR 10.16 62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 63 M.S. GRILL WORKS 64 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1 65 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece DSR 10.5.2 66 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 67 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 68 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 69 BASEMENT WORK 70 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 71 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 72 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 73 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). DSR 4.1.10 74 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1 75 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 76 BASKETBALL COURT 77 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 78 Synthetic Specification: -Providing and laying of ITF Classified material. 8 layers System Synthetic Acrylic for Synthetic Basketball Court:-(1 layer) Conrete Primer(2 layer) Resurfacer(3 layer) Cushion Rubber(4 layer) Top CoatWhite Line Marking as per standard 79 Basketball pole fix type 6” round pipe , Projection 2*20 Acrylic board 20mm Malaysia with dunking ring (3 spring) 80 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P. 81 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 82 SPORTS FACILITIES 83 LAWN TENNIS COURT 84 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 85 Synthetic Specification: -Providing and laying of ITF Classified imported material (AcryCoat Made In Europe)8 layers System Synthetic Acrylic for Synthetic Court :-• (1 Layer) Concrete Primer • (2 layers) Acrylic Resurfacer• (3 layers) Cushion • (2 layers) Top Coat•Line Marking 86 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P 87 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 88 Pole socket type 80*80 mm , thickness (4 mm) with net 89 SKATING RING 90 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 91 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverableseparately). DSR 16.75 92 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksDSR 10.25.2 93 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.New work (Two or more coats) DSR 16.47.1 94 HORTRICULTURE AND LANSCAPING 95 Supply and stacking of of good earth at site including royaltyand carriage up to 1 Km DSR 2.2 96 Supply and stacking of sludge at site including royalty and carriage up to 1 Km DSR 2.3 97 Supply and stacking of dump manure from approved source at site including carriage up to 1 Km DSR 2.4.3 98 Rough dressing the trenched ground including breaking of clods DSR 2.5 99 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.6 100 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.7 101 Spreading of sludge, dump manure and or good earth and mixing as per direction of engineer incharge DSR 2.8+2.9 102 Grassing with selection No-1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn. free from weeds and fit for moving and disposal of rubbish as directed DSR 2.10.1 103 Half brick circular treeguard in brick 1.25 m internal dia and of ht 1.20 m above ground and 0.20 m below ground..... DSR 2.15 104 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. DSR 2.54 105 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. DSR 2.56 106 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge DSR 7.5 107 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.24 108 Supply and stacking of Ficus bengalensis (Bargad) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.28 109 Supply and stacking of Ficus elastica Decora (Rubber plant) plant of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 7.31 110 Supply and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-incharge DSR 7.63 111 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. DSR 7.75 112 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge DSR 2.28 113 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge DSR 2.33 114 Plumbing Detail 115 SANITARY FIXTURES 116 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1 117 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR 17.78 118 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.. DSR 17.80 119 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 120 Providing and fixing toilet paper holder : C.P. brass DSR 17.34.1 121 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single holebasinmixer. 122 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. DSR 17.10.1.1 123 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore DSR 18.53.1 124 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore DSR 18.51.1 125 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore DSR 18.16.1 126 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 127 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. MR 128 Providing and fixing of SS coat hook complete in all respect as approved by Engineer In Charge MR 129 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.DSR 17.70.1 130 Providing and fixing of SS grab bar complete in all respect as approved by Engineer In Charge MR 131 Providing and fixing urinal partition chinaware complete in all respect MR 132 Providing and fixing of sink mixer complete in all respect. MR 133 Providing and fixing SS labourtory sink as per detailMR 134 Providing and fixing laboratory sink mixer complete in all respect.MR 135 Providing and fixing drinking water sink complete in all respects MR 136 SOIL , WASTE AND VENT SYSTEM 137 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings: 75 mm dia 138 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 100 mm dia 139 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 150 mm dia 140 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless : 100 mm inlet and 100 mm outlet DSR 17.60.1 141 Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. DSR 18.58.1.1 142 Providing and fixing floor clean out plug consist of CI bend & GI socket heavy class with Brass cap & key for opening male threaded cap etc. including lead caulked to CI pipescomplete in all respects as per drawing / sample approved by Engineer -in -ChargeFCO (floor clean out plug shall be flushed with floor finish: 100 mm dia/150 mm dia 143 Water Supply system 144 Inside Toilets 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work. DSR 18.9 146 15 mm nominal outer dia. Pipes. 147 20 mm nominal outer dia. Pipes. 148 25 mm nominal outer dia. Pipes. 149 Distribution lines 150 Providing and fixing of GI Pipes medium class IS :1239 including all required fittings etc. DSR 18.12 151 20 mm dia. nominal bore 152 25 mm dia. nominal bore 153 32 mm dia. nominal bore 154 40 mm dia. nominal bore 155 50 mm dia. nominal bore 156 65 mm dia. nominal bore 157 80 mm dia. nominal bore 158 100 mm dia. nominal bore 159 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore DSR 18.13.1 160 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore DSR 18.13.2 161 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). DSR 18.14 162 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore: DSR 18.17 163 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. DSR 18.17.2 164 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore DSR 18.17.3 165 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR 18.17.4 166 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore DSR 18.17.5 167 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore DSR 18.17.6 168 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore DSR 18.18.1 169 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore DSR 18.18.2 170 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore DSR 18.18.3 171 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 172 Providing and fixing submrsible vertical drainage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand bysolid hanldling 40 mm size.discharge 5 lps and head-15 mtr 173 Providing and fixing submrsible vertical sewage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr 174 RAIN WATER SYSTEM 175 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 100 mm dia 176 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 150 mm dia 177 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 200 mm dia 178 Making of 600x600 mm size khurah complete in all respects including water proofing etc. 179 EXTERNAL SEWARAGE AND DRAINAGE 180 GARDEN IRRIGATION 181 Providing and fixing HDPE pipes conforming to IS:4984 PE 63 Class IV (6 kg/sqcm) including all fittings, e.g.couplings, tees, bends, reducers and screwed adoptors, welded joint as per manufacturers recommendations. 182 a) 32 mm O.D. 183 b) 40 mm O.D. 184 c) 63 mm O.D. 185 Providing and fixing uPVC Schedule 40 pipes conforming to ASTM D-1785complete with uPVC Schedule 40 fittings including necessary cutting of pipes, jointing with HDPE pipe with sadddle fitting completewith testing and commissioning of pipe lines : (a) 1 nominal size 186 Providing and fixing 25 mm brass dia quick coupling valve fitting with auto-close lid, SS spring, brass valve, complete in all respects (Harit model HT-71Bor eq.). 187 Providning and fixing bronze ball valve with screwed female/flangedends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tetsed to 20 kg/sqcm 188 a) 25 mm nominal bore 189 b) 40 mm nominal bore 190 a) 50 mm nominal bore 191 Providing and fixing cast iron flanged wafer type butterfly Valve with quarter turn operation complete in all respects confirming to IS:13095 PN1.0: (a) 65 mm dia 192 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. cover 500x450 mm R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 193 Providing and fixing 15 mm N.B. air release valve alongwith FTA I/c 1 no. ball valve for fixing to HDPE pipeline complete 194 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 195 SEWERAGE 196 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 197 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (b)Extra over 1 (a) above for excavation over 1.5 m depth . 198 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD 199 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD 200 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (c) 300 mm OD 201 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. :(a) 200 mm OD 202 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. (b) 250 mm OD 203 Providing and fixing square mouth S.W. gully trap grade A complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water & gas tight SFRC Cover with frame of 260x260 mm size clear opening, frame of size 390x390 mm with weight of frame to be not less than 10 Kg and cover of size 300x300 mm with weightof cover not to be not less than 9 Kg as per standard design: (a) 180X 150 mm size P type with F.P.S. bricks of class designation 75 204 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 205 Extra for depth beyond 45 cm of brick masonary chamber : for 455X610 mm size : With F.P.S. bricks 206 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand)inside cement plaster 12mm thick with cement mortar1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement 3 Coarse sand: 6graded stone aggregate 40mm nominal size) and making necessary channelin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) finished witha floating coat of neat cement all complete as per standard design: 0.91 m deep with SFRC cover and frame ( Heavy duty HD-20 gradedesignation) 560mm internal diameter conforming to IS:12592 total weightof cover and frame to be not less than 182 kg, fixed in cement concrete1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (excavation, foot rests and 12 mm thick cement plaster at the surface shall be paid seperately): with F.P.S. bricks class desigantion 75 207 Extra depth for circular type manhole 0.91 m internal dia (at bottom) with beyond 0.91 m to 1.67 m, withF.P.S. bricks class designation 75 208 DRAINAGE SYSTEM 209 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 210 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (b) Pipes, cables etc. exceeding 300 mm dia. 211 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(a) 200 mm OD 212 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 250 mm OD 213 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 300 mm OD 214 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (a) 200 mm OD 215 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (b) 250 mm OD 216 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (a) Inside size 90X80 cms and 60 cms deep including SFRC cover with frame (heavy duty) 500 mm dia clear opening 217 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (b) Inside size 120X90 cms and 90 cms deep including SFRC cover with frame (Extra heavy duty) 560 mm dia clear opening. 218 Extra for additional depth of manholes: (a) Size 90X80 cms beyond 60 cms depth 219 Extra for additional depth of manholes: (b) Size 120X90 cms beyond 90 cms depth 220 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 221 Constructing brick masonary road gully chamber 50X45X60 cm with bricksof class designation 75 in cement mortar 1:5 (1 cement: 5 fine sand) including 500X450 mm precast RCC horizontal grating with frame complete as per standard design:With F.P.S. bricks 222 Making connection of stormwater lines with existing municipal manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: (a) For pipes 250 to 450 mm diameter 223 FIRE FIGHTING WORKS 224 FIRE FIGHTING 225 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(a) 80 mm dia ( 4.85mm thickness) 226 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(b) 100 mm dia ( 5.40mm thickness) 227 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(c) 150 mm dia ( 5.40mm thickness) 228 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(a) 100 mm dia 229 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(b) 150 mm dia 230 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(a) 100 mm dia 231 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(b) 150 mm dia 232 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:( a) 65 mm dia 233 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:(b) 150 mm dia 234 Supply, Installation, Testing and Commisioning ofC.I.`Y strainer with bronzeperforatedsheetbasket includingrubber gasket, flanges, nuts, bolts and washers, complete as required.: (a) 150 mm dia 235 Supply, Installation, Testing and Commisioning of SS single head fire hydrant valvewith80 mm N.B.flangedinlet, brass spindal, one no. 63 mm dia femaleinstantaneousoutlet type. G.M. coupling,blank cap, chain. Conforming to IS:5290.Includingtappingfromwet riser complete as required. 236 Supply, Installation, Testing and Commisioning ofHose pipe, 63 mm diaand15mts long, duly reinforced, rubberlined suitable forbrusting pressurenot lessthan22Kg/Sqcm. conformingtoIS 636-1988type A with gun metal heavy dutyinstantaneous type coupling ( Pairmale&femaleparts) conforming to IS 903. Complete as required. 237 Supply, Installation, Testing and Commissioning of63 mm dia instantaneouspattern branchshort SSpipe,16 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 238 Supply, Installation, Commisioning of standard firemans axe with heavy rubber handle. 239 Supply, Installation, Testing and Commissioning ofinletbreaching havingC.I.bodyfourway SS 63 mm diainstantaneousinlets conforming toIS 903fittedwithnon returnvalves, 25 mm diagun metal drain cock, blank cap, brasschains and 150 mm dia flanges with allaccessories suitableforlocal fire tender complete as required. 240 Supply, Installation, Testing and Commissioning ofSS Fire Brigadeadopter assemblywith150mm diaoutlet,suitableforlocalfire tender complete as required. 241 Supply, Installation, Testing and Commissioning of weather proof cabinet of size not less than0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and painting in red coloursuitableto accomodate, externalyard hydrant valve, 2 nos15 mtrlongHose pipe, branch pipe, nozzle and fire mans axe. It shall be mounted on boundary wall complete as required. 242 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.: Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.: M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head 243 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump): Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.: 2280 lpm at 70 m Head 244 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.: Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.: M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.: Suitable cement concrete foundation duly plastered and with anti vibration pads. : 180 lpm at 70 m Head 245 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 246 INCOMING:250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc:LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING:( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 247 Jockey Pump : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL 248 Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 249 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe 250 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 251 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 252 FINISHING WORK 253 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.1.2 254 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)DSR 21.1.2.2 255 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides DSR 21.2.2 256 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness: DSR 21.3.2 257 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm: DSR 9.95.1 258 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm: DSR 9.96.1 259 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm: DSR 9.97.1 260 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm: DSR 9.100.1 261 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper: DSR 9.101.2 262 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturers specification.: Two or more coats on new work: DSR 13.42.1 263 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap: DSR 5.44.1 264 Providing and fixing of expansion joint system related with wall joint (internal / external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.): Wall Joint of 100 mm gap:DSR 5.45.1 265 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) : Roof Joint of 100 mm gap : DSR 5.46.1 266 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 267 CONNECTING BRIDGE 268 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete. DSR 10.2 269 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 270 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62 271 ROOF SKYLIGHT -18 mm THK POLYCARBONATE SHEET Supply and Installation of polycarbonate multi-layered, Multicell Xfix Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system of minimum 18 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof.Panels shall be with grip lock double tooth lockingmechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS tructure (will be paid Separately) with self-drilling screws and specialsTrapezoidal Heavy Duty Fastener/ Al- Cleat to ensure a pull-out load of min. 7000N (7KN) testedas per ISO 6892:1998 and IS 1608: 2005. The min width of the panel system shall be 900mm (min.). 272 Panels shall be uniform in color UV protected in combination with seven layers for required lux level, along with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels with morelayers will be preferred for better insulation and improved shading coefficient. Prices includes All accessories including Aluminum profiles with EPDM Gaskets, at alternate edges with taper cutting to achieve the required profile, aesthetics and performance criteria. U value shall not be more than 1.8 Watt/m2K as per EN ISO 1077- 2:2018 and respective third Party test certificate shall be produced before procurement. 273 Panels shall have an X cell structure also called truss bracing design to have more strength and flexibility simultaneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155.Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factoryauthorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. 274 LEVELLING 275 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR 2.31 276 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.32 277 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.33 278 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.: Beyond 60 cm girth upto and including 120 cm girth: SOR 2.33.2 279 EXTERNALELECTRICAL 280 COMPACT SUB STATIONS - 01 (with OLTC) 281 Supply, Installation, testing and Commissioning of 11 kV / 0.415 KV Compact Sub Station(with OLTC)outdoor plinth mounted type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated VCB compact switchgear (RMU) having metal enclosed robotically sealed/welded stainless steel tank , L T Panel, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type, otherassociated equipment etc. complete as required conforming to detailed specification. 282 The enclosure shall have modular construction usingG.I. sheets and shall be painted with polyurethane paint from the exterior of approved shade. The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP23 ingress protection. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.Transformer compartment door shall be interlocked with HT breaker.The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank. 283 The L T ACB shall have inbuiltmicroprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases with Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 284 L T Panel BUS : 415 Volts, 3 phase 50 HZTPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. 285 The Transformer losses should confirm to IS - 1180 Part-1 (2014) efficiency Level - 2[ 1.86 KW at 50% load & 5.3 KW at 100% load shall not exceeds by 5.0% of the maximum total loss values. 286 The combination of CSS shall be as per details below:- 287 (a) Supply of 3 way 11kV ,3Phase, 50Hz, 3 wire , earthed neutral, Indoor type floor mounted, non extensible, having hinged arc proof cable doors, breaking capacity 18.4 kA,VCB Ring Main Unit enclosed in robotically laser welded stainless steel tank having IP67 degree of protection consisting of following:- 288 (i) 1 Nos. 630Amps Fault making load breaking spring assisted SF6 Ring Switches, fitted with fixed type voltage indicator device as per IEC 61958 along with associated sensor and fault passage indicator.(ii) 2 No. 630Amps tee off spring assisted type vacuum circuit breaker unit with self powered series trip microprocessor based numericalover current and Earth faultrelay for protection, fitted with fixed type voltage indicator device as per IEC 61958, along with associated sensor and fault passage indicator and ring core type protection Current transformer along with LV compartment with Ammeter with selector switches.(iii)Air Insulated Metering panel connected along with above unit , 18.4 kA , 630 amps, having Potential transformer,connected jumpers / Bus Bar, LV Compartment to incorporate Votmeter andEnergy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI as per the requirement (at incoming VCB) (Please refer SLD). 289 (b)1 No. 11 KV/415 V, 630 KVA three phase (with %Z is 4.5%) , 50 HZ, DYn11, +10% to -10%in 2.5% equal steps ON LOADTAP CHANGER (OLTC), oil cooled, outdoor mounting type, hermitically sealed, corrugated wall design low loss transformer with Cu winding and standard fittings.(minimum 240 Sq MM HT (E) XLPE AL cable are used for the connectivity between transformer &HT Breaker) 290 LT Bus Bars : 1000 AMP,500 Volts, 3 phase 50 HZTPN. The current density of bus bar shall not exceed1.0 sqmm / Amp 291 Neutral Bus : - Separate 2 nos 32 x 6 mm Copper insulated strip (with conductivity mim 99%) directly connected from neutral point of transformer. 292 (c )Incoming cum Outgoing - 415 VoltL.T. breaker Panel having 1000 Amp FP ACB, 50 kA fixed type, with microprocessor based O/L, E/F, S/C, Inst. S/C releases with CT/PT, ammeter with ASS, Voltmeter with VSS, PF meter, Hz meter, energy enalyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI,phase indicating lamps, On/Offf/Trip indication. 630 KVA Compact Sub Station. 293 DIESEL GENERATING SET 294 Supply, Installation, testing and Commissioning ofSilent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization / PLC based load manager, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. 295 Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. 296 Instrument Panel - Engine mounted Instrument Panel fitted withand having digital display for followings : 297 Start stop switch with keyWater temperature indicationLubrication oil pressure indication.Lubrication oil temperature indication.Battery charging indicationRPM indicationOver speed indicationLow Lube oil trip indicationEngine hours indication 298 Alternator- Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. 299 Note : - Alternator should have with all other accessories as per specified in Technical specfications. 300 Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.Inbuilt Fuel tank ofstandard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.Daily service Fuel tank of990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system,level indicators and all standard accessories etc. as required.Exhaust Silencer - Exhaust manifold with residential silencer.The D G set should be supplied with required hardware for external PLC based auto load management system.Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. 301 550 KVA 302 Supply, Fixing, testing and Commissioning of Exhaust gas piping system ofClass `B MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil.The measurement shall be doneon the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will gowell above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will beconfirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval): 300 mm dia (wall thickness - 4.85 mm) (for 625 KVA DG sets) 303 Supply & fixing of SSBellow of following diameter : 300 mm dia(for 500 KVA DG sets) 304 Supply & fabrication ofD G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MSangle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. 305 FUEL PIPING 306 Providing and fixing in position the following MSpipes classC (As per IS : 1239) cut to required lenghts and installed with screwed joints including providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, MS supports and accessories including digging and refilling earth where required for buried pipes / suspended from ceiling including pipe hanger / clamped from wall including hardware complete as per site requirement.: 25 mm NB MS pipes (IS: 1239, 4.0 mm thick) 307 Providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with PVC grip, teflon seat, screwed ends tested to a pressure of 10 kg/sqcm suitable for HSD complete.:25 mm nominal bore 308 Supply, installation, testing and commissioning of Fuel Level sensor (for Low & high level) 309 MAIN LT PANEL & SUB DISTRIBUTION PANELS 310 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete withsuitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 311 INCOMING-800 Amp. MCCB-1 Nos.OUTGOINGS -1 nos. 200 AMPS TP MCCB. (25 KA)2 no. 100 AMPS TP MCCB. (25 KA)2 nos. 63 AMPS TP MCCB. (25 KA)1 nos. 200 AMPS TP MCCB. (25 KA) (for spare)1 nos. 100 AMPS TP MCCB. (25 KA) (for spare)1 nos. 63 AMPS TP MCCB. (25 KA) (for spare) 312 AUTOMATIC POWER FACTOR CORRECTION PANEL(CAPACITOR PANEL) 313 Supply, Installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 200 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR at 415 Volts (rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust &vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623All outgoings MCCBs shall be thermal-magnetic based with inbuilt O/L & S/C release.All MCCBs shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CTs, PTs, etc 314 Capacitor duty contactors should be used for switching individual capacitor banks.The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.The capacitor panel shall be integrated with the main L T Panel as per schematic diagram 315 INCOMINGIncomer circuit breaker has been included in the main panel.1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden formetering.1Nos- (0-600A) digital Ammeter with selector switchMicro processor based automatic power factor control relay (3phase) (including power factor meter) in 9 steps for automaticcut off or add on capacitor units to keep the power factor at0.95 with variation of loads. All associated auxiliary contactors /relays shall be provided with in the scope of work.Phase indicating lamps with HRC fuses, and indicating in eachcapacitor chamber unit to indicate On/Off status of capacitorunit.BUS BARS600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivityelectrolytic Aluminium bus bar with conductivity on min 57 to58% of suitable length, SMC / DMC supports, with colourcoding and insulated by heat shrinkable sleeves and clips onshrouds for joints. The current density of bus bar shall beminimum 1.0 sq mm / amp.The Maximum allowable temperature for the Bus bar to berestricted to 85 deg C. The temperature rise should berestricted to 35 deg C above ambient temperature. 316 OUTGOINGS -2 nos. of 125 AMPS TPN 25 KA MCCB and 150 amps AC3 dutycontactor with 50 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.2 nos. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 25 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 20 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 40 AMPS TPN 25 KA MCCB and 50 amps AC3 dutycontactor with 15 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 32 AMPS TPN 25 KA MCCB and 40 amps AC3 dutycontactor with 10 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 16 AMPS TPN 25 KA MCCB and 20 amps AC3 dutycontactor with 5 KVAR heavy duty MPP type at 415 V capacitorbank (rated Voltage 440 Volts) , auto-manual selector switch,start stop push button for manual operation including on/offindicating lamps and delay timer complete.1 SET 200 KVAR CAPACITOR PANEL 317 Electrical Panel-1 (Block-1)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamberetc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 318 Electrical Panel-2 (Block-2)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving andmounted on non hygroscopic supports such as CMC/BMCsupport withdeteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 5 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 319 Electrical Panel-3 (Block-3)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and otherparameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 813 (E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 320 Electrical Panel-4 (Block-4)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/ 812 (C)INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 321 Electrical Panel-5 (Block-5)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/813(E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 322 Lighting Panel for Basement :Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 / 811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 5 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 323 UPS O/G Panel:Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as perIS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 2 nos.40 AMP MCCB 18 no.25 AMP MCCB 18 no.40 AMP MCCB 1 no. (spare)25 AMP MCCB 1 no. (spare) 324 CO2 Gas Flooding System For Main LT PanelSupply, installation, testing and commissioning of Polymer Tube Detection based CO2 Gas Flooding System For Main LT Panel, Consisting of the following components: CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 325 CO2 Cylinder, 2.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 326 Filling adopter 327 D/I Adopter for converting the indirect valve to function as Direct System. 328 FET End of Line adapter with Pressure gauge for Automatic fireuppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives. 329 Pressure Switch to monitor Pressure drop in the tube, switchpoint 11 Bars. 330 Flexible Polymer Detection Tube made by special modified Polyamide (PA), Color Red, High grade quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, Melting Point approx. 220 degrees Celsius when heating up with 10 K/minute, Steady load tested upto max. 80° C. The lowest operating temperature is stipulated at minus 40°C. Service Pressure 20 Bar, Burst Pressure at 20 Deg C approx 120 Bars, Release Temperature : Rapid heat increase in temperature at 20 bars pressure approx 150 Deg to 180 Deg C (Without Flame) 331 Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries +electrical wiring to make each entire system functional.(Indeginous) 332 Containing all required fitting and fixing 333 Installation & Commissioning Charges includes complete setup of the system, Installation of Cylinders on specially designed brackets, Laying of sensor tubes using tube attachments and Cable ties, fixing end of line plugs and end of line adapters, pressurizing tube @ 15-18 Bars using Nitrogen pressurizingagent. 334 Supplying and fixing and connection of the following rating, four Pole MCCB (25 KA), 415 volts, at the incomer / outgoing in seperate enclosure, complete with connections, testing and commissioning etc. as required : 100 AMP FP MCCB (25 KA) micro processor based. 335 (VI) INVERTORSupply, installation, testing and commissioning of on lineUPS with builtin parallal redundancy, as per following detailsTechnology : Micro processor based controls, True on line,Double conversion type, should have cold start facility.Input :- (mains / local D G set compatibility)a) Voltage : 415 V / 3 Phaseb) Voltage Variation : - 20% to + 20%c) Input Frequency : 50 Hz.d) Frequency Variation : + 10%e) Automatic phase sequence correction facilityOutput :-a) Voltage : 230 V / 1 Phase, 415 V / 3 Phaseb) Voltage Variation : + 1%c) Frequency Variation : 50 Hz. + 0.1%Overall Efficiency : > 90%Charger : Should have built in charger to suit systemrequirement.Battery type : Sealed Maintenance Free - SMF (Global Yuasa /Exide)Battery Backup = 15 min.External battery backup will be usedDisplay : Should have LCD display with event logging facility.Upgradeability : Should be upgradeable to work as parallelredundant UPS in load sharing mode.Software Communication : Should have SNMP (Simple NetworkManagement Protocol) compatibilityRating : 30 KVA 336 SUB-HEAD - 1 : S/F MODULAR TYPE SWITCH / SOCKET & SUBMAINS 337 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.DSR 1.57 338 Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. DSR 1.14 339 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4) 340 2 X 16 sq. mm + 1 X 6 sq. mm earth wire(DSR 1.14.6) 341 4 X 6 sq. mm + 2 X 6 sq. mm earth wire(DSR 1.14.9) 342 4 X 10 sq. mm + 2X6 sq. mm earth wire(DSR 1.14.10) 343 SUB-HEAD - 2 : DISTRIBUTION BOARDS & CIRCUIT BREAKERS 344 S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge. a) 12 WAYS CAT A (UPSOR 1025(A) 345 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. (a) 4 WAYS CAT A (UPSOR 1026 (A) 346 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. 6 WAYS : CAT A (UPSOR 1027(A) 347 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. : 8 WAYS: CAT A (UPSOR UPSOR 1028(A) 348 Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) : CAT A(UPSOR 1002 349 Supply & fixing of 63 Amp DP MCB (10 KA) :CAT A : UPSOR 1011 350 S/F of 63 amp FP MCB (10 K.A.) :CAT A : UPSOR 1020 (A) 351 S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.UPSOR 394 352 S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. UPSOR 398 353 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. UPSOR 1109 354 S&F single pole MCB blanking plate UPSOR 1034(B) 355 SUPPLY AND LAYING OF CABLES & ACCESSORIES 356 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor byclamps etc UPSOR (501) 357 6 sqmm 3 core 358 10 sqmm 4 core 359 16 sqmm 4 core 360 25 sqmm 3 1/2 core 361 35 sqmm 3 1/2 core 362 50 sqmm 3 1/2 core 363 95 sqmm 3 1/2 core 364 120 sqmm 3 1/2 core 365 150 sqmm 3 1/2 core 366 185 sqmm 3 1/2 core 367 240 sqmm 3 1/2 core 368 300 sqmm 3 1/2 core 369 deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required. 370 Supply fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge (UP SOR 504) 371 6 sqmm 372 10 sqmm 373 16 sqmm 374 25 sqmm 375 35 sqmm 376 50 sqmm 377 70 sqmm 378 95 sqmm 379 120 sqmm 380 150 sqmm 381 185 sqmm 382 240 sqmm 383 300 sqmm 384 Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor UPSOR 503 385 6 sqmm 3 core 386 10 sqmm 4 core 387 16 sqmm 4 core 388 25 sqmm 3 1/2 core 389 35 sqmm 3 1/2 core 390 50 sqmm 3 1/2 core 391 95 sqmm 3 1/2 core 392 120 sqmm 3 1/2 core 393 150 sqmm 3 1/2 core 394 185 sqmm 3 1/2 core 395 240 sqmm 3 1/2 core 396 300 sqmm 3 1/2 core 397 Supply of ISI marked Copper conductor PVC insulated cable as per IS 1554 armoured, served, sheathed 1100 volts grade. : 25 sqmm 1 core 398 Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or inside existing RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-incharge. (The supply of terminations and glands shall be under seperate item): (a) 25 sqmm 1 core 399 Supply and laying of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, double compression glands, supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-incharge. Armoured 400 6 x 2.5 sq mm armoured (DG to Main LT panel interfacing) 401 12 x 2.5 sq mm armoured (2 runs DG controlling) 402 12 x 2.5 sq mm armoured ( For Transformer contro wiring) 403 2 x 4 sq mm armoured (for Battery charging) 404 Supply of 3 core stranded aluminium conductor 11 KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments) a) 240 sq. mm 3 core 405 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of following size in the existing masonry open duct etc. as required.a) Size exceeding 120 sq. mm. But not exceeding 400 sq. mm. 406 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 407 Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 408 CABLE TRAY 409 Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.: The support for 1000mm, 900 mm and 750 mm wide cable tray will be by 50 x 50 x 6 mm MS angle, for 600mm and 450 mm wide cable tray will be by 40 x 40 x 5 mm MS angle, for 300mmwide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mmwide cable tray will be by 25 x 25 x 4 mm MS angle. 410 900 mm (W) X 50 mm (H) X 2 mm (T) 411 750 mm (W) X 50 mm (H) X 2 mm (T) 412 600 mm (W) X 50 mm (H) X 2 mm (T) 413 450 mm (W) X 50 mm (H) X 2 mm (T) 414 300 mm (W) X 35 mm (H) X 1.5 mm (T) 415 150 mm (W) X 35 mm (H) X 1.5 mm (T) 416 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 417 90 mm dia (OD-90 mm & ID-76 mm nominal) (DSR 14.16.2) 418 160 mm dia (OD-160 mm & ID-135 mm nominal) DSR 14.16.4) 419 MISCELLANEOUS ITEMS EXTERNAL ELECTRICAL 420 Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.21) 421 Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.22 422 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) UPSOR 1134 423 Supply and fixing of Fist aid box as approved by Indian red cross conforming to IS : 2217. 424 Supply of rubber gloves of 11 KV grade as per IS : 4770. 425 Supply and fixing of cable route maker as directed by Engg-incharge. UPSOR 505 426 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality. to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) UPSOR 1136 427 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality to withstand 45 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV Panels) UPSOR 1136 428 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.a) 300 mm dia. DSR 14.14.4 429 Supply and erection of pregalvanized Ladder type cable trays made out 25mm x 75mm x 25mm x 2.5mm GI Section all along (as runner) and 20mm x 30mm x 20mm x 2.5 mm GI Section (as rungs) at every 250mm interval c/c including tees, bends, crossings, reducers, couplings to be laid over head on wall or hanged from ceiling including all neccessary supports, brackets (50x50x6 MS Angle) at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts &bolts complete in all respects. 430 900 mm (W) X 75 mm (H) 431 750 mm (W) X 75 mm (H) 432 EARTHING 433 BODY / SAFETY EARTHING (FOR BODY OF ALL ELECTRICAL EQUIPMENTS LIKE RISING MAINS, TRANSFORMER, DG SETS,LIFTS ETC. 434 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel). please refer submitted drawing. 435 Providing & fixing 25mm x 5mm G.I. strip on surface, in recess or in ground including connections etc. as required (LT Panel,Cable Trays & Elevator). DSR 5.15 436 Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (Pig tail) UPSOR 717 437 Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (SubstationGrid) 438 NEUTRAL EARTHING 439 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6mm. please refer submitted drawing. 440 Providing & fixing 32mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. asrequired. 441 SOLAR PLANT 442 ON-Line Solar Photovoltaic system plant including suitable rating Poly crystalline Silicon PV Modules having a efficiency of minimum 15% (without any power export arrangement), String combiner box, DC Distribution board etc. complete as required. Scope of work also includes supply, installation of GI structure, (80 micron) in suitable section complete with all accessories and hardware including civil work as required at site for mounting PV panels.: 15 kWp SET 170 415 V, 3 phase, 50 Hz AC power string inverter (Grid intractive) with stand & all protection and controls having overall efficeiency of not less than 95%. : 15 kWp (nominal) SET 171 AC distribution board made of 2 mm CRCA sheet, power coated having IP55 degree of protection (for indoor installation) for terminating 415 V, 3 phase, 50 Hz power suppled from inverter complete height with following multifunction: - Digital multifunction meter (EM 6400 of Schnieder or equal) - 40 Amp TPN MCB (10 KA) - Phase indicating lamps. SET 1Lighting Arrestor SET 1Surge Protector SET 1 443 STREET / EXTERNAL LIGHTING 444 Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(UPSOR 653) 445 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect.Category AAA (UPSOR 1455) 446 Supply and fixingof LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect.Category AAA (UPSOR 1443) 447 Supply and fixingof 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminiumbody with drive set . Confirming to IP 65 and above Protection complete in all respect.Category AAA (UPSOR) MR 448 Supply and fixingof 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR 1441) 449 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect.Category AAA 450 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation,excavation & back filling and Required T&P completee in all respect. 451 Supply installation, testing and commissioning of 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from MCB in cable junction box of pole to luminaire along with MCB & Connector complete as required. 452 Supply & burrying of 40 mm dia x 4.50 m long G.I. pipe vertically for earthing having 12 mm dia holes spaced 75 mm apart drilled upto 2 meter brom the bottom complete with one earthing lead of no. 6 to 8 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switchboard (from apron to switch board the cost of GI pipe & GI wire will be extra), 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect. 453 Supply & burrying of 600mm x 600 mm x 6.0 mm G.I. plate, vertically for pole earthing with its top at least 3 m below ground level complete 20mm dia. G. I. pipe and funnel for watering and one earthing lead of no. 8 to 10 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 454 Supplying & Laying of one number 8 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site. 455 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 456 INCOMER : 457 f (ii) 40 AMP TPN MCB (10 KA) 458 e (ii) 25 AMP TPN MCB (10 KA) 459 OUT GOINGS : 460 4 nos. 6-32 AMP DP MCB (10 KA) 461 24 nos. 6-32 AMP DP MCB (10 KA) 462 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 10 sqmm 3 core 463 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Size not exceeding 35 sq. mm. 464 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Size not exceeding 35 sq. mm. 465 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe etc. as required. Size not exceeding 35 sq. mm. 466 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. e) 6 sqmm 3 core 467 Deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
28.
Housing Urban and Rular Development #9440739 Technical Bid
Construction Of Phase-B Works At Jawahar Navodaya Vidyalaya At Ramgarh ( Jharkhand ) - 1 0.375 BOYS DORMITORY WITH 2 NOS. WARDEN RESIDENCE(G+1) 2 CIVIL WORK 3 Earth Work 4 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil 7 Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. 8 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 9 Concrete Work 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stoneaggregate 40 mm nominal size derived from natural sources) 11 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 12 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 13 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 14 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 15 Reinforced Cement Concrete 16 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 17 Foundations, footings, bases of columns, etc. for mass concrete. 18 Suspended floors, roofs, landings, balconies and access platform. 19 Lintels, beams, plinth beams, girders, bressumers 20 Columns,Pillars, Piers, Abutments, Posts and Struts. 21 Edges of slabs and breaks in floors and walls Under 20 cm wide. 22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 23 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 24 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 25 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 26 All works upto plinth level 27 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 28 (i) R.C.C. work in Footing 29 (ii) R.C.C. work in Beam 30 (iii) R.C.C. work in Columns 31 All works above plinth level upto floor V level 32 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 33 (i) R.C.C. work in Lintel 34 (ii) R.C.C. work in Beam 35 (iii) R.C.C. work in Columns 36 (iv) R.C.C. work in Slab 37 Expansion Joint Treatment 38 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that commodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 39 Floor Joint of 100 mm gap 40 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 41 Wall Joint of 100 mm gap 42 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement.(Material shall confirm to ASTM 6063.) 43 Roof Joint of 100 mm gap 44 Masonry Work 45 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 46 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 47 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V levelin : Cement mortar 1:6 (1 cement : 6 coarse sand) 48 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 49 Cladding Work 50 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 51 Granite stone slab colour black, Cherry/Ruby red 52 Area of slab upto 0.50 sqm 53 Area of slab over 0.50 sqm 54 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 55 Granite work 56 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 57 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 58 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 59 Wood and PVC Work 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 61 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 62 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 63 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 64 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 65 300 mm weighing not less than 200 gms 66 250 mm weighing not less than 150 gms 67 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 68 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 69 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick 70 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood 71 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 72 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 73 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete.(a) 250mm x 16mm . 74 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 75 200 x 10mm 76 150 x 10mm 77 Steel Work 78 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 79 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 80 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 81 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 82 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 83 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 84 Flooring 85 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 88 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 90 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 91 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 92 P & laying cement concrete 93 Finishing 94 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 95 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 96 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 97 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 98 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 99 Steel Painting:Applying priming coat: 100 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 101 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 102 Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade : 103 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 104 Water Proofing 105 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 106 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 107 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tilesof class designation 10 108 Providing and filling of AAC Lightweight Broken Blocks sunken portions. 109 2.1 Mt high Boundary wall 110 PLUMBING INTERNAL ESTIMATE( 0.375 Unit Boys Dormitory with 2 Nos Warden Residence ) 111 Sub Head– I Sanitary Installation 112 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 113 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 114 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 115 W.C. pan with ISI marked white solid plastic seat and lid 116 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 117 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 118 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 119 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 120 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 121 Providing and fixing toilet paper holder : 122 C.P. brass 123 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 124 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 125 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 126 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 127 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 128 Kitchen sink with drain board 129 510x1040 mm bowl depth 250mm 130 Kitchen sink without drain board 131 610x460 mm bowl depth 200 mm 132 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 133 Size 450x300x150 mm 134 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 135 Flexible pipe 136 40 mm dia 137 Providing and fixing soil, waste and vent pipes : 138 100 mm dia 139 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 140 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 141 100 mm 142 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 143 Providing and fixing plain bend of required degree. 144 100 mm 145 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 146 Providing and fixing heel rest sanitary bend 147 100 mm dia 148 Sand cast iron S&S as per IS - 3989 149 Providing and fixing double equal plain junction of required degree 150 100x100x100x100 mm 151 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 152 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 153 100x100x100 mm 154 sand cast Iron S&S as per IS: 3989 155 Providing and fixing single equal plain junction of required degree 156 100x100x100 mm 157 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 158 Providing and fixing terminal guard: 159 100 mm 160 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 161 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 162 100 mm 163 S S 304 grade coupling with EPDM rubber gasket 164 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 165 100 mm 166 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 167 100 mm diameter pipe 168 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 169 100 mm diameter pipe 170 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 171 32 mm dia. nominal bore 172 40 mm dia. nominal bore 173 50 mm dia. nominal bore 174 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 175 100 mm inlet and 100 mm outlet 176 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 177 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 178 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 179 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 180 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 181 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 182 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 183 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 184 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 185 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 186 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 187 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 188 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 189 Coupler 190 110 mm 191 Single tee with door 192 110x110x110 mm 193 Bend 87.5° 194 110 mm 195 Shoe (Plain) 196 110 mm Shoe 197 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 198 110 mm 199 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 200 110 mm outer dia 201 50 mm outer dia 202 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 203 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 204 Sub Head– II Water Supply 205 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 206 Internal work – Exposed on wall. 207 20 mm nominal outer dia Pipes 208 25 mm nominal outer dia Pipes 209 32 mm nominal outer dia Pipes 210 40 mm nominal outer dia Pipes 211 50 mm nominal outer dia Pipes 212 65 mm nominal outer dia Pipes 213 80 mm nominal outer dia Pipes 214 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 215 Concealed including cutting chases and making good the wall etc. 216 15 mm nominal outer dia Pipes 217 20 mm nominal outer dia Pipes 218 25 mm nominal outer dia Pipes 219 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 220 20 mm dia. nominal bore 221 25 mm dia. nominal bore 222 32 mm dia. nominal bore 223 40 mm dia. nominal bore 224 50 mm dia. nominal bore 225 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 226 25 mm nominal bore 227 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 228 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 229 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 230 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 231 15 mm nominal bore 232 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 233 15 mm nominal bore 234 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 235 15mm nominal bore 236 Providing and fixing uplasticised PVC connection pipe with brass unions : 237 45 cm length 238 15 mm nominal bore 239 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 240 150 mm diameter 241 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 242 (a) 15 mm nominal dia 243 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 244 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 245 upto 50 mm dia. nominal bore 246 SUBHEAD– III Drainage 247 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 248 150 mm diameter 249 200 mm diameter 250 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 251 180x150 mm size P type 252 With fly ash bricks (non modular) bricks of class designation 7.5 253 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 254 150 mm dia. R.C.C. pipe 255 250 mm dia. R.C.C. pipe 256 300 mm dia. R.C.C. pipe 257 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 258 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 259 with common brunt clay FPS ( non modular )bricks of class designation 7.5 260 Extra depth formanhole 90x80 cm 261 With FPSbricks class designation 7.5 262 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 263 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 264 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 265 ELECTRICAL Works 0.375 BOYS DORMITORY WITH 2 NOS. WARDEN RESIDENCE 266 SUB HEAD - I: CIRCUIT CUM POINT WIRING 267 SWITCH CONTROL LIGHT POINTS 268 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 269 Group C 270 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 271 Group C 272 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 273 Group C 274 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 275 Group C 276 MCB CONTROL LIGHT POINTS 277 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 278 Primary point controlled by one MCB. 279 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 280 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 281 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 282 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 283 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 284 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 285 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 286 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 287 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 288 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 289 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 290 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 291 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 292 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 293 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 294 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 295 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 296 Telephone socket outlet 297 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 298 1 or 2 Module (75mmX75mm) 299 6 module (78mm X 205 mm X 50 mm) 300 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 301 3 pin , 5/6 amps socket outlet 302 5/6 amps switch 303 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 304 25 mm 305 32 mm 306 SUBHEAD -II - FITTINGS & FIXTURES 307 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 308 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 309 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 310 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 311 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 312 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 313 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 314 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 315 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 316 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 317 SUBHEAD - III - DISTRIBUTION BOARDS 318 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 319 6 way, Double door 320 8 way, Double door 321 12 way, Double door 322 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 323 4 way (4 + 12), Double door 324 6 way (4 + 18), Double door 325 8 way (4 + 24), Double door 326 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 327 12 way (4 + 36), Double door 328 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 329 Single Pole 330 Single Pole Neutral 331 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 332 40 A 333 63 A 334 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 335 25 A 336 40 A 337 63 A 338 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 339 25 A 340 40 A 341 63 A 342 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 343 SUB HEAD-IV , LIGHTNING CONDUCTOR 344 LIGHTNING CONDUCTOR 345 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 346 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 347 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 348 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 349 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 350 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 351 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 352 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 353 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 354 0.375 GIRLS DORMITORY WITH 3 NOS. WARDEN RESIDENCE(G+2) 355 CIVIL WORK 356 Earth Work 357 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 358 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 359 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil 360 Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. 361 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 362 Concrete Work 363 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 364 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 365 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 366 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 367 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 368 Reinforced Cement Concrete 369 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 370 Foundations, footings, bases of columns, etc. for mass concrete. 371 Suspended floors, roofs, landings, balconies and access platform. 372 Lintels, beams, plinth beams, girders, bressumers 373 Columns,Pillars, Piers, Abutments, Posts and Struts. 374 Edges of slabs and breaks in floors and walls Under 20 cm wide. 375 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 376 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 377 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 378 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 379 All works upto plinth level 380 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 381 (i) R.C.C. work in Footing 382 (ii) R.C.C. work in Beam 383 (iii) R.C.C. work in Columns 384 All works above plinth level upto floor V level 385 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 386 (i) R.C.C. work in Lintel 387 (ii) R.C.C. work in Beam 388 (iii) R.C.C. work in Columns 389 (iv) R.C.C. work in Slab 390 Expansion Joint Treatment 391 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that commodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 392 Floor Joint of 100 mm gap 393 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 394 Wall Joint of 100 mm gap 395 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to 396 accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement.(Material shall confirm to ASTM 6063.) 397 Roof Joint of 100 mm gap 398 Masonry Work 399 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 400 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 401 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V levelin : Cement mortar 1:6 (1 cement : 6 coarse sand) 402 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) 403 Cladding Work 404 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 405 Granite stone slab colour black, Cherry/Ruby red 406 Area of slab upto 0.50 sqm 407 Area of slab over 0.50 sqm 408 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 409 Granite work 410 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 411 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 412 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 413 Wood and PVC Work 414 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 415 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 416 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 417 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 418 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 419 300 mm weighing not less than 200 gms 420 250 mm weighing not less than 150 gms 421 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 422 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 423 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick 424 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood 425 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 426 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 427 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 428 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 429 300 x 10mm 430 150 x 10mm 431 Steel Work 432 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 433 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 434 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 435 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 436 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 437 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 438 Flooring 439 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement 440 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 441 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 442 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 443 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 444 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 445 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 446 P & laying cement concrete 447 Finishing 448 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 449 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 450 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 451 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 452 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 453 Steel Painting:Applying priming coat: 454 With ready mixed aluminium primer of approved brand and manufacture on resinouswood and plywood 455 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 456 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: Two or more coats on new work. 457 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 458 Water Proofing 459 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 460 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 461 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 462 Providing and filling of AAC Lightweight Broken Blocks sunken portions. 463 2.1 Mt high Boundary wall with concertina coil 464 2.1 Mt high Boundary wall 465 PLUMBING INTERNAL ESTIMATE ( 0.375 Unit Girls Dormitory with 3 Nos Warden Residence ) 466 Sub Head– I Sanitary Installation 467 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 468 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 469 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 470 W.C. pan with ISI marked white solid plastic seat and lid 471 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 472 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 473 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 474 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 475 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 476 Providing and fixing toilet paper holder : 477 C.P. brass 478 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 479 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 480 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 481 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 482 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 483 Kitchen sink with drain board 484 510x1040 mm bowl depth 250mm 485 Kitchen sink without drain board 486 610x460 mm bowl depth 200 mm 487 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 488 Size 450x300x150 mm 489 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 490 Flexible pipe 491 40 mm dia 492 Providing and fixing soil, waste and vent pipes : 493 100 mm dia 494 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 495 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 496 100 mm 497 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 498 Providing and fixing plain bend of required degree. 499 100 mm 500 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 501 Providing and fixing heel rest sanitary bend 502 100 mm dia 503 Sand cast iron S&S as per IS - 3989 504 Providing and fixing double equal plain junction of required degree 505 100x100x100x100 mm 506 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 507 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 508 100x100x100 mm 509 sand cast Iron S&S as per IS: 3989 510 Providing and fixing single equal plain junction of required degree 511 100x100x100 mm 512 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 513 Providing and fixing terminal guard: 514 100 mm 515 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 516 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 517 100 mm 518 S S 304 grade coupling with EPDM rubber gasket 519 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 520 100 mm 521 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 522 100 mm diameter pipe 523 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 524 100 mm diameter pipe 525 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 526 32 mm dia. nominal bore 527 40 mm dia. nominal bore 528 50 mm dia. nominal bore 529 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 530 100 mm inlet and 100 mm outlet 531 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 532 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 533 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 534 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 535 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 536 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 537 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 538 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 539 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 540 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 541 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 542 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 543 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 544 Coupler 545 110 mm 546 Single tee with door 547 110x110x110 mm 548 Bend 87.5° 549 110 mm 550 Shoe (Plain) 551 110 mm Shoe 552 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 553 110 mm 554 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 555 110 mm outer dia 556 50 mm outer dia 557 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 558 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 559 Sub Head– II Water Supply 560 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 561 Internal work – Exposed on wall. 562 20 mm nominal outer dia Pipes 563 25 mm nominal outer dia Pipes 564 32 mm nominal outer dia Pipes 565 40 mm nominal outer dia Pipes 566 50 mm nominal outer dia Pipes 567 65 mm nominal outer dia Pipes 568 80 mm nominal outer dia Pipes 569 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 570 Concealed including cutting chases and making good the wall etc. 571 15 mm nominal outer dia Pipes 572 20 mm nominal outer dia Pipes 573 25 mm nominal outer dia Pipes 574 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 575 20 mm dia. nominal bore 576 25 mm dia. nominal bore 577 32 mm dia. nominal bore 578 40 mm dia. nominal bore 579 50 mm dia. nominal bore 580 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 581 25 mm nominal bore 582 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 583 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 584 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 585 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 586 15 mm nominal bore 587 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 588 15 mm nominal bore 589 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 590 15mm nominal bore 591 Providing and fixing uplasticised PVC connection pipe with brass unions : 592 45 cm length 593 15 mm nominal bore 594 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 595 150 mm diameter 596 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 597 (a) 15 mm nominal dia 598 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 599 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 600 upto 50 mm dia. nominal bore 601 SUBHEAD– III Drainage 602 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 603 150 mm diameter 604 200 mm diameter 605 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 606 180x150 mm size P type 607 With fly ash bricks (non modular) bricks of class designation 7.5 608 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 609 150 mm dia. R.C.C. pipe 610 250 mm dia. R.C.C. pipe 611 300 mm dia. R.C.C. pipe 612 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 613 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 614 with common brunt clay FPS ( non modular )bricks of class designation 7.5 615 Extra depth formanhole 90x80 cm 616 With FPSbricks class designation 7.5 617 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 618 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 619 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 620 ELECTRICAL Works 0.375 GIRLS DORMITORY WITH 3 NOS. WARDEN RESIDENCE 621 SUB HEAD - I: CIRCUIT CUM POINT WIRING 622 SWITCH CONTROL LIGHT POINTS 623 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 624 Group C 625 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 626 Group C 627 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 628 Group C 629 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 630 Group C 631 MCB CONTROL LIGHT POINTS 632 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 633 Primary point controlled by one MCB. 634 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 635 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 636 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 637 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 638 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 639 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 640 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 641 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 642 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 643 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 644 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 645 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 646 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 647 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 648 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 649 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 650 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 651 Telephone socket outlet 652 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 653 1 or 2 Module (75mmX75mm) 654 6 module (78mm X 205 mm X 50 mm) 655 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 656 3 pin , 5/6 amps socket outlet 657 5/6 amps switch 658 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 659 25 mm 660 32 mm 661 SUBHEAD -II - FITTINGS & FIXTURES 662 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 663 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 664 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 665 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 666 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 667 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 668 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 669 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 670 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 671 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 672 SUBHEAD - III - DISTRIBUTION BOARDS 673 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 674 6 way, Double door 675 8 way, Double door 676 12 way, Double door 677 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 678 4 way (4 + 12), Double door 679 6 way (4 + 18), Double door 680 8 way (4 + 24), Double door 681 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 682 12 way (4 + 36), Double door 683 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 684 Single Pole 685 Single Pole Neutral 686 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 687 40 A 688 63 A 689 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 690 25 A 691 40 A 692 63 A 693 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 694 25 A 695 40 A 696 63 A 697 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 698 SUB HEAD-IV , LIGHTNING CONDUCTOR 699 LIGHTNING CONDUCTOR 700 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 701 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 702 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 703 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 704 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 705 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 706 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 707 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 708 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 709 [ VICE PRINCIPALRESIDENCE ] (TYPE-4) 710 Earth Work 711 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. 712 All kinds of soil 713 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 714 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 715 Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. 716 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 717 Concrete Work 718 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneIII)derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 719 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 720 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 721 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 722 Brick edging in full brick width and half brick depth including excavation refilling and disposal of surplus earth lead upto 50 metres. With common burnt clayF.P.S.(non modulur)bricks of class designation 75 723 Reinforced Cement Concrete 724 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 725 Foundations, footings, bases of columns, etc. for mass concrete. 726 Suspended floors, roofs, landings, balconies and access platform. 727 Lintels, beams, plinth beams, girders, bressumers 728 Columns,Pillars, Piers, Abutments, Posts and Struts. 729 Edges of slabs and breaks in floors and walls Under 20 cm wide. 730 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 731 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 732 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 733 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 734 All works upto plinth level 735 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 736 (i) R.C.C. work in Footing 737 (ii) R.C.C. work in Beam 738 (iii) R.C.C. work in Columns 739 All works above plinth level upto floor V level 740 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 741 (i) R.C.C. work in Lintel 742 (ii) R.C.C. work in Beam 743 (iii) R.C.C. work in Columns 744 (iv) R.C.C. work in Slab 745 Masonry Work 746 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 747 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 748 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V levelin : 749 Cement mortar 1:6 (1 cement : 6 coarse sand) 750 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 751 Cladding Work 752 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 753 Area of slab upto 0.50 sqm 754 Area of slab over 0.50 sqm 755 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 756 Granite work 757 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 758 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 759 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 760 Wood and PVC Work 761 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 762 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 763 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 764 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 765 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 766 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous finecellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven selftapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as permanufacturers specification and direction of Engineer-in-charge. 767 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 768 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size, Kiln seasoned and chemically treated hollock wood 769 3000 Series Windows( Double Rebate with Air Tight Glass Shutter Windows)Providing& Fixing 3000 Series Windows fabricated from roll formed sections made of Galvanized Steel Colour Coated/Powder Coated (Base Steel as per IS 513 “D” quality, Galvanized as per IS 277 with Zinc of 120 grams/Sq. Mtr.) with total coated thickness of 0.60 mm.Paint Specifications:Coated Sections should be with Primer Coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester Paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns, or Powder Coated with pure Polyester Powder up to 50-60 microns thick. 770 Dimensions of Sections:Section for Frame should be of 98mm X 50mm, Section for Mullion should be of 46mm X 70mm, Section for Shutter Frame should be of 46mm X 46 mm, Section for Fixed Glass Bead should be of 18mm X 25mm and Section for Fly mesh Shutter Frame should be of 20mm X 40mm.Fixing Details:Frame and Mesh Shutter Sections should be cut to length and mitre joined with Corner Bracket made of Polypropylene. Glass Shutter should be mitre joined with corner brackets made of CRCA electroplated. Mullion Section should be joined with Frame/ Mullion using Nylon Mullion Cap Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter between Frame and Glazed Shutter and both sides of Fixed Glass. Spoon Profile should be used around Fly mesh to fix Mesh in Mesh Shutter. 771 Accessories:Each Glazed Shutter should be provided with MS Powder Coated Friction Hinges – 1 set, High Grade Aluminum Powder Coated Handle -1 No. Each Mesh shutter should be provided with S.S.Pivot Hinges-1 set, Elixir make handle shall be provided per shutter.Window Frame should be fixed to brick/concrete masonary by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frames.Glass: Glass shutter & Fixed Glass portions should be provided with a glass of 4MM Plain Float Glass.MeshMesh Shutter should be provided with a Stainless Steel 32 gauge Fly mesh of 304 grades with 144 holes per square Inch.Grill:-Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm center-to-center, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. (Make: A2Z Infra Solutions/ Elixir Metform Pvt Ltd./ Lakshmi Fabrications) 772 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 773 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 774 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 775 300 x 10mm 776 150 x 10mm 777 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer in-charge. 778 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressedBWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 779 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah, cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge. 780 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction ofEngineer-in-charge. 200 mm for CB 781 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction ofEngineer-in-charge. 100 mm for Kitchen Cabinets 782 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand tocupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete asperdirection of Engineer-in-charge 783 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge 784 SS Hanging Rod for CB 785 Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets : 786 Steel Work 787 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 788 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes (weights not less than 10 kg/ sqm) 789 Flooring 790 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 791 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 792 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet forplacing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish ofsize of Tile 600 x 600 mm 793 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. 794 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 795 Finishing 796 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 797 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 798 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 799 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 800 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 801 Applying priming coat: 802 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 803 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 804 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: 805 Two or more coats on new work. 806 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work 807 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 808 Water Proofing 809 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 810 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 811 PLUMBING INTERNAL ESTIMATE ( Type-4/Vice Principal Residence) 812 Sub Head– I Sanitary Installation 813 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 814 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 815 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 816 W.C. pan with ISI marked white solid plastic seat and lid 817 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 818 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 819 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 820 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 821 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 822 Providing and fixing toilet paper holder : 823 C.P. brass 824 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 825 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 826 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 827 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 828 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 829 Kitchen sink with drain board 830 510x1040 mm bowl depth 250mm 831 Kitchen sink without drain board 832 610x460 mm bowl depth 200 mm 833 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 834 Size 450x300x150 mm 835 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 836 Flexible pipe 837 40 mm dia 838 Providing and fixing soil, waste and vent pipes : 839 100 mm dia 840 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 841 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 842 100 mm 843 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 844 Providing and fixing plain bend of required degree. 845 100 mm 846 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 847 Providing and fixing heel rest sanitary bend 848 100 mm dia 849 Sand cast iron S&S as per IS - 3989 850 Providing and fixing double equal plain junction of required degree 851 100x100x100x100 mm 852 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 853 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 854 100x100x100 mm 855 sand cast Iron S&S as per IS: 3989 856 Providing and fixing single equal plain junction of required degree 857 100x100x100 mm 858 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 859 Providing and fixing terminal guard: 860 100 mm 861 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 862 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 863 100 mm 864 S S 304 grade coupling with EPDM rubber gasket 865 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 866 100 mm 867 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 868 100 mm diameter pipe 869 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 870 100 mm diameter pipe 871 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 872 32 mm dia. nominal bore 873 40 mm dia. nominal bore 874 50 mm dia. nominal bore 875 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 876 100 mm inlet and 100 mm outlet 877 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 878 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 879 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 880 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 881 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 882 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 883 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 884 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 885 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 886 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 887 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 888 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 889 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 890 Coupler 891 110 mm 892 Single tee with door 893 110x110x110 mm 894 Bend 87.5° 895 110 mm 896 Shoe (Plain) 897 110 mm Shoe 898 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 899 110 mm 900 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 901 110 mm outer dia 902 50 mm outer dia 903 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 904 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 905 Sub Head– II Water Supply 906 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 907 Internal work – Exposed on wall. 908 20 mm nominal outer dia Pipes 909 25 mm nominal outer dia Pipes 910 32 mm nominal outer dia Pipes 911 40 mm nominal outer dia Pipes 912 50 mm nominal outer dia Pipes 913 65 mm nominal outer dia Pipes 914 80 mm nominal outer dia Pipes 915 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 916 Concealed including cutting chases and making good the wall etc. 917 15 mm nominal outer dia Pipes 918 20 mm nominal outer dia Pipes 919 25 mm nominal outer dia Pipes 920 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 921 20 mm dia. nominal bore 922 25 mm dia. nominal bore 923 32 mm dia. nominal bore 924 40 mm dia. nominal bore 925 50 mm dia. nominal bore 926 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 927 25 mm nominal bore 928 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 929 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 930 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 931 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 932 15 mm nominal bore 933 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 934 15 mm nominal bore 935 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 936 15mm nominal bore 937 Providing and fixing uplasticised PVC connection pipe with brass unions : 938 45 cm length 939 15 mm nominal bore 940 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 941 150 mm diameter 942 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 943 (a) 15 mm nominal dia 944 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 945 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 946 upto 50 mm dia. nominal bore 947 SUBHEAD– III Drainage 948 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 949 150 mm diameter 950 200 mm diameter 951 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 952 180x150 mm size P type 953 With fly ash bricks (non modular) bricks of class designation 7.5 954 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 955 150 mm dia. R.C.C. pipe 956 250 mm dia. R.C.C. pipe 957 300 mm dia. R.C.C. pipe 958 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 959 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 960 with common brunt clay FPS ( non modular )bricks of class designation 7.5 961 Extra depth formanhole 90x80 cm 962 With FPSbricks class designation 7.5 963 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 964 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 965 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 966 ELECTRICAL Works TYPE - 4 RESIDENCE (VICE PRINCIPAL RESIDENCE) 967 SUB HEAD - I: CIRCUIT CUM POINT WIRING 968 SWITCH CONTROL LIGHT POINTS 969 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 970 Group C 971 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 972 Group C 973 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 974 Group C 975 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 976 Group C 977 MCB CONTROL LIGHT POINTS 978 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 979 Primary point controlled by one MCB. 980 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 981 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 982 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 983 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 984 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 985 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 986 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 987 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 988 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 989 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 990 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 991 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 992 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 993 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 994 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 995 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 996 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 997 Telephone socket outlet 998 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 999 1 or 2 Module (75mmX75mm) 1000 6 module (78mm X 205 mm X 50 mm) 1001 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1002 3 pin , 5/6 amps socket outlet 1003 5/6 amps switch 1004 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1005 25 mm 1006 32 mm 1007 SUBHEAD -II - FITTINGS & FIXTURES 1008 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 1009 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 1010 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 1011 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 1012 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 1013 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 1014 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 1015 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 1016 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1017 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 1018 SUBHEAD - III - DISTRIBUTION BOARDS 1019 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1020 6 way, Double door 1021 8 way, Double door 1022 12 way, Double door 1023 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 1024 4 way (4 + 12), Double door 1025 6 way (4 + 18), Double door 1026 8 way (4 + 24), Double door 1027 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 1028 12 way (4 + 36), Double door 1029 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1030 Single Pole 1031 Single Pole Neutral 1032 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1033 40 A 1034 63 A 1035 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1036 25 A 1037 40 A 1038 63 A 1039 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1040 25 A 1041 40 A 1042 63 A 1043 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1044 SUB HEAD-IV , LIGHTNING CONDUCTOR 1045 LIGHTNING CONDUCTOR 1046 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 1047 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 1048 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1049 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 1050 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1051 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1052 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 1053 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 1054 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 1055 [ TYPE-III RESIDENCES G+2, 6UNITS. ] 1056 Earth Work 1057 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. 1058 All kinds of soil 1059 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 1060 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 1061 Supplying and filling in plinth with sand under floors, including watering, ramming ,consolidating and dressing complete. 1062 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1063 Concrete Work 1064 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 1065 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 1066 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1067 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 1068 Brick edging in full brick width and half brick depth including excavation refilling and disposal of surplus earth lead upto 50 metres. With common burnt clayF.P.S.(non modulur)bricks of class designation 75 1069 Reinforced Cement Concrete 1070 Centering and shuttering including strutting, propping etc. and removal of form for all heights 1071 Foundations, footings, bases of columns, etc. for mass concrete. 1072 Suspended floors, roofs, landings, balconies and access platform. 1073 Lintels, beams, plinth beams, girders, bressumers 1074 Columns,Pillars, Piers, Abutments, Posts and Struts. 1075 Edges of slabs and breaks in floors and walls Under 20 cm wide. 1076 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 1077 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 1078 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 1079 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of theminimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1080 All works upto plinth level 1081 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 1082 (i) R.C.C. work in Footing 1083 (ii) R.C.C. work in Beam 1084 (iii) R.C.C. work in Columns 1085 All works above plinth level upto floor V level 1086 Concrete of M25 grade with minimum cement content of 330 kg /cum 1087 (i) R.C.C. work in Lintel 1088 (ii) R.C.C. work in Beam 1089 (iii) R.C.C. work in Columns 1090 (iv) R.C.C. work in Slab 1091 Masonry Work 1092 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : cement mortar 1:4 (1 cement : 4 coarse sand) 1093 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 1094 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) 1095 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 1096 Cladding Work 1097 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1098 Granite stone slab colour black, Cherry/Ruby red 1099 Area of slab upto 0.50 sqm 1100 Area of slab over 0.50 sqm 1101 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 1102 Granite work 1103 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 1104 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1105 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1106 Wood and PVC Work 1107 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI markedStainless Steel butt hinges with necessary screws 1108 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1109 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 1110 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 1111 300 mm weighing not less than 200 gms 1112 250 mm weighing not less than 150 gms 1113 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 1114 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous finecellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven selftapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as permanufacturers specification and direction of Engineer-in-charge. 1115 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick 1116 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size 1117 Kiln seasoned and chemically treated hollock wood 1118 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 1119 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1120 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1121 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1122 300 x 10mm 1123 150 x 10mm 1124 Steel Work 1125 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1126 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1127 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1128 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 1129 SS RALING 1130 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 1131 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 1132 Flooring 1133 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 1134 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1135 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 1136 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm 1137 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm 1138 Finishing 1139 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 1140 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 1141 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 1142 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 1143 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 1144 Steel Painting:Applying priming coat 1145 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1146 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 1147 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: 1148 Two or more coats on new work. 1149 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1150 Water Proofing 1151 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1152 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1153 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 1154 Providing and filling of AAC Lightweight Broken Blocks sunken portions. 1155 PLUMBING INTERNAL ESTIMATE ( Type-3 ,6 Unit ) (G+2) 1156 Sub Head– I Sanitary Installation 1157 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 1158 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 1159 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1160 W.C. pan with ISI marked white solid plastic seat and lid 1161 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 1162 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 1163 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1164 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 1165 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 1166 Providing and fixing toilet paper holder : 1167 C.P. brass 1168 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 1169 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 1170 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 1171 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 1172 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 1173 Kitchen sink with drain board 1174 510x1040 mm bowl depth 250mm 1175 Kitchen sink without drain board 1176 610x460 mm bowl depth 200 mm 1177 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 1178 Size 450x300x150 mm 1179 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 1180 Flexible pipe 1181 40 mm dia 1182 Providing and fixing soil, waste and vent pipes : 1183 100 mm dia 1184 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 1185 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1186 100 mm 1187 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 1188 Providing and fixing plain bend of required degree. 1189 100 mm 1190 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1191 Providing and fixing heel rest sanitary bend 1192 100 mm dia 1193 Sand cast iron S&S as per IS - 3989 1194 Providing and fixing double equal plain junction of required degree 1195 100x100x100x100 mm 1196 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1197 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1198 100x100x100 mm 1199 sand cast Iron S&S as per IS: 3989 1200 Providing and fixing single equal plain junction of required degree 1201 100x100x100 mm 1202 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1203 Providing and fixing terminal guard: 1204 100 mm 1205 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1206 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 1207 100 mm 1208 S S 304 grade coupling with EPDM rubber gasket 1209 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 1210 100 mm 1211 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1212 100 mm diameter pipe 1213 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 1214 100 mm diameter pipe 1215 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1216 32 mm dia. nominal bore 1217 40 mm dia. nominal bore 1218 50 mm dia. nominal bore 1219 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1220 100 mm inlet and 100 mm outlet 1221 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 1222 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 1223 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 1224 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 1225 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 1226 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 1227 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 1228 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 1229 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 1230 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1231 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1232 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 1233 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1234 Coupler 1235 110 mm 1236 Single tee with door 1237 110x110x110 mm 1238 Bend 87.5° 1239 110 mm 1240 Shoe (Plain) 1241 110 mm Shoe 1242 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1243 110 mm 1244 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 1245 110 mm outer dia 1246 50 mm outer dia 1247 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 1248 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 1249 Sub Head– II Water Supply 1250 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1251 Internal work – Exposed on wall. 1252 20 mm nominal outer dia Pipes 1253 25 mm nominal outer dia Pipes 1254 32 mm nominal outer dia Pipes 1255 40 mm nominal outer dia Pipes 1256 50 mm nominal outer dia Pipes 1257 65 mm nominal outer dia Pipes 1258 80 mm nominal outer dia Pipes 1259 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1260 Concealed including cutting chases and making good the wall etc. 1261 15 mm nominal outer dia Pipes 1262 20 mm nominal outer dia Pipes 1263 25 mm nominal outer dia Pipes 1264 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1265 20 mm dia. nominal bore 1266 25 mm dia. nominal bore 1267 32 mm dia. nominal bore 1268 40 mm dia. nominal bore 1269 50 mm dia. nominal bore 1270 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1271 25 mm nominal bore 1272 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 1273 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 1274 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1275 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1276 15 mm nominal bore 1277 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1278 15 mm nominal bore 1279 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1280 15mm nominal bore 1281 Providing and fixing uplasticised PVC connection pipe with brass unions : 1282 45 cm length 1283 15 mm nominal bore 1284 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 1285 150 mm diameter 1286 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 1287 (a) 15 mm nominal dia 1288 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 1289 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 1290 upto 50 mm dia. nominal bore 1291 SUBHEAD– III Drainage 1292 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 1293 150 mm diameter 1294 200 mm diameter 1295 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 1296 180x150 mm size P type 1297 With fly ash bricks (non modular) bricks of class designation 7.5 1298 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1299 150 mm dia. R.C.C. pipe 1300 250 mm dia. R.C.C. pipe 1301 300 mm dia. R.C.C. pipe 1302 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 1303 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 1304 with common brunt clay FPS ( non modular )bricks of class designation 7.5 1305 Extra depth formanhole 90x80 cm 1306 With FPSbricks class designation 7.5 1307 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1308 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 1309 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1310 ELECTRICAL Works TYPE-3 (G+2) RESIDENCE 1311 SUB HEAD - I: CIRCUIT CUM POINT WIRING 1312 SWITCH CONTROL LIGHT POINTS 1313 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1314 Group C 1315 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 1316 Group C 1317 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 1318 Group C 1319 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 1320 Group C 1321 MCB CONTROL LIGHT POINTS 1322 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 1323 Primary point controlled by one MCB. 1324 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 1325 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 1326 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1327 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1328 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1329 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1330 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 1331 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 1332 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 1333 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 1334 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 1335 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 1336 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 1337 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 1338 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 1339 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 1340 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1341 Telephone socket outlet 1342 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1343 1 or 2 Module (75mmX75mm) 1344 6 module (78mm X 205 mm X 50 mm) 1345 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1346 3 pin , 5/6 amps socket outlet 1347 5/6 amps switch 1348 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1349 25 mm 1350 32 mm 1351 SUBHEAD -II - FITTINGS & FIXTURES 1352 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 1353 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 1354 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 1355 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 1356 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 1357 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 1358 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 1359 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 1360 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1361 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 1362 SUBHEAD - III - DISTRIBUTION BOARDS 1363 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1364 6 way, Double door 1365 8 way, Double door 1366 12 way, Double door 1367 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 1368 4 way (4 + 12), Double door 1369 6 way (4 + 18), Double door 1370 8 way (4 + 24), Double door 1371 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 1372 12 way (4 + 36), Double door 1373 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1374 Single Pole 1375 Single Pole Neutral 1376 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1377 40 A 1378 63 A 1379 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1380 25 A 1381 40 A 1382 63 A 1383 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1384 25 A 1385 40 A 1386 63 A 1387 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1388 SUB HEAD-IV , LIGHTNING CONDUCTOR 1389 LIGHTNING CONDUCTOR 1390 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 1391 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 1392 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1393 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 1394 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1395 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1396 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 1397 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 1398 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 1399 [ TYPE-II RESIDENCES G+2, 6 UNITS. ] 1400 Earth Work 1401 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1402 All kinds of soil 1403 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 1404 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil 1405 Supplying and filling in plinth with sand under floors, including watering, ramming ,consolidating and dressing complete. 1406 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1407 Concrete Work 1408 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneIII)derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 1409 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 1410 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1411 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 1412 Brick edging in full brick width and half brick depth including excavation refilling and disposal of surplus earth lead upto 50 metres. With common burnt clayF.P.S.(non modulur)bricks of class designation 75 1413 Reinforced Cement Concrete 1414 Centering and shuttering including strutting, propping etc. and removal of form for all heights 1415 Foundations, footings, bases of columns, etc. for mass concrete. 1416 Suspended floors, roofs, landings, balconies and access platform. 1417 Lintels, beams, plinth beams, girders, bressumers 1418 Columns,Pillars, Piers, Abutments, Posts and Struts. 1419 Edges of slabs and breaks in floors and walls Under 20 cm wide. 1420 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 1421 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 1422 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 1423 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of theminimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1424 All works upto plinth level 1425 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 1426 (i) R.C.C. work in Footing 1427 (ii) R.C.C. work in Beam 1428 (iii) R.C.C. work in Columns 1429 All works above plinth level upto floor V level 1430 Concrete of M25 grade with minimum cement content of 330 kg /cum 1431 (i) R.C.C. work in Lintel 1432 (ii) R.C.C. work in Beam 1433 (iii) R.C.C. work in Columns 1434 (iv) R.C.C. work in Slab 1435 Masonry Work 1436 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : cement mortar 1:4 (1 cement : 4 coarse sand) 1437 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 1438 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) 1439 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 1440 Cladding Work 1441 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1442 Granite stone slab colour black, Cherry/Ruby red 1443 Area of slab upto 0.50 sqm 1444 Area of slab over 0.50 sqm 1445 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 1446 Granite work 1447 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 1448 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1449 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1450 Wood and PVC Work 1451 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI markedStainless Steel butt hinges with necessary screws 1452 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1453 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 1454 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 1455 300 mm weighing not less than 200 gms 1456 250 mm weighing not less than 150 gms 1457 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 1458 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 1459 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesivebonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 1460 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size 1461 Kiln seasoned and chemically treated hollock wood 1462 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 1463 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1464 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1465 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1466 300 x 10mm 1467 150 x 10mm 1468 Steel Work 1469 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1470 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1471 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1472 SS RALING 1473 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 1474 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 1475 Flooring 1476 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 1477 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1478 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 1479 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm 1480 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm 1481 Finishing 1482 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 1483 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 1484 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 1485 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 1486 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 1487 Steel Painting:Applying priming coat 1488 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1489 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 1490 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: 1491 Two or more coats on new work. 1492 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1493 Water Proofing 1494 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1495 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1496 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 1497 Providing and filling of AAC Lightweight Broken Blocks sunken portions. 1498 PLUMBING INTERNAL ESTIMATE ( Type-2,6 Nos.) G+2 1499 Sub Head– I Sanitary Installation 1500 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 1501 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 1502 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1503 W.C. pan with ISI marked white solid plastic seat and lid 1504 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 1505 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 1506 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1507 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 1508 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 1509 Providing and fixing toilet paper holder : 1510 C.P. brass 1511 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 1512 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 1513 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 1514 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 1515 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 1516 Kitchen sink with drain board 1517 510x1040 mm bowl depth 250mm 1518 Kitchen sink without drain board 1519 610x460 mm bowl depth 200 mm 1520 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 1521 Size 450x300x150 mm 1522 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 1523 Flexible pipe 1524 40 mm dia 1525 Providing and fixing soil, waste and vent pipes : 1526 100 mm dia 1527 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 1528 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1529 100 mm 1530 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 1531 Providing and fixing plain bend of required degree. 1532 100 mm 1533 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1534 Providing and fixing heel rest sanitary bend 1535 100 mm dia 1536 Sand cast iron S&S as per IS - 3989 1537 Providing and fixing double equal plain junction of required degree 1538 100x100x100x100 mm 1539 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1540 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1541 100x100x100 mm 1542 sand cast Iron S&S as per IS: 3989 1543 Providing and fixing single equal plain junction of required degree 1544 100x100x100 mm 1545 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1546 Providing and fixing terminal guard: 1547 100 mm 1548 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1549 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 1550 100 mm 1551 S S 304 grade coupling with EPDM rubber gasket 1552 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 1553 100 mm 1554 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1555 100 mm diameter pipe 1556 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 1557 100 mm diameter pipe 1558 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1559 32 mm dia. nominal bore 1560 40 mm dia. nominal bore 1561 50 mm dia. nominal bore 1562 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1563 100 mm inlet and 100 mm outlet 1564 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 1565 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 1566 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 1567 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 1568 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 1569 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 1570 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 1571 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 1572 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 1573 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1574 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1575 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm dia 1576 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1577 Coupler 1578 110 mm 1579 Single tee with door 1580 110x110x110 mm 1581 Bend 87.5° 1582 110 mm 1583 Shoe (Plain) 1584 110 mm Shoe 1585 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1586 110 mm 1587 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 1588 110 mm outer dia 1589 50 mm outer dia 1590 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 1591 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 1592 Sub Head– II Water Supply 1593 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1594 Internal work – Exposed on wall. 1595 20 mm nominal outer dia Pipes 1596 25 mm nominal outer dia Pipes 1597 32 mm nominal outer dia Pipes 1598 40 mm nominal outer dia Pipes 1599 50 mm nominal outer dia Pipes 1600 65 mm nominal outer dia Pipes 1601 80 mm nominal outer dia Pipes 1602 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1603 Concealed including cutting chases and making good the wall etc. 1604 15 mm nominal outer dia Pipes 1605 20 mm nominal outer dia Pipes 1606 25 mm nominal outer dia Pipes 1607 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1608 20 mm dia. nominal bore 1609 25 mm dia. nominal bore 1610 32 mm dia. nominal bore 1611 40 mm dia. nominal bore 1612 50 mm dia. nominal bore 1613 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1614 25 mm nominal bore 1615 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 1616 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 1617 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1618 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1619 15 mm nominal bore 1620 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1621 15 mm nominal bore 1622 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1623 15mm nominal bore 1624 Providing and fixing uplasticised PVC connection pipe with brass unions : 1625 45 cm length 1626 15 mm nominal bore 1627 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 1628 150 mm diameter 1629 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 1630 (a) 15 mm nominal dia 1631 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 1632 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 1633 upto 50 mm dia. nominal bore 1634 SUBHEAD– III Drainage 1635 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 1636 150 mm diameter 1637 200 mm diameter 1638 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 1639 180x150 mm size P type 1640 With fly ash bricks (non modular) bricks of class designation 7.5 1641 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1642 150 mm dia. R.C.C. pipe 1643 250 mm dia. R.C.C. pipe 1644 300 mm dia. R.C.C. pipe 1645 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 1646 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 1647 with common brunt clay FPS ( non modular )bricks of class designation 7.5 1648 Extra depth formanhole 90x80 cm 1649 With FPSbricks class designation 7.5 1650 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1651 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 1652 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1653 ELECTRICAL Works TYPE-2 (G+2) RESIDENCE 6 Nos 1654 SUB HEAD - I: CIRCUIT CUM POINT WIRING 1655 SWITCH CONTROL LIGHT POINTS 1656 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1657 Group C 1658 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 1659 Group C 1660 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 1661 Group C 1662 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 1663 Group C 1664 MCB CONTROL LIGHT POINTS 1665 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 1666 Primary point controlled by one MCB. 1667 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 1668 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 1669 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1670 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1671 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1672 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1673 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 1674 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 1675 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 1676 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 1677 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 1678 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 1679 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 1680 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 1681 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 1682 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 1683 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1684 Telephone socket outlet 1685 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1686 1 or 2 Module (75mmX75mm) 1687 6 module (78mm X 205 mm X 50 mm) 1688 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1689 3 pin , 5/6 amps socket outlet 1690 5/6 amps switch 1691 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1692 25 mm 1693 32 mm 1694 SUBHEAD -II - FITTINGS & FIXTURES 1695 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 1696 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 1697 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 1698 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 1699 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 1700 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 1701 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 1702 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 1703 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1704 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 1705 SUBHEAD - III - DISTRIBUTION BOARDS 1706 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1707 6 way, Double door 1708 8 way, Double door 1709 12 way, Double door 1710 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 1711 4 way (4 + 12), Double door 1712 6 way (4 + 18), Double door 1713 8 way (4 + 24), Double door 1714 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 1715 12 way (4 + 36), Double door 1716 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1717 Single Pole 1718 Single Pole Neutral 1719 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1720 40 A 1721 63 A 1722 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1723 25 A 1724 40 A 1725 63 A 1726 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1727 25 A 1728 40 A 1729 63 A 1730 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1731 SUB HEAD-IV , LIGHTNING CONDUCTOR 1732 LIGHTNING CONDUCTOR 1733 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 1734 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 1735 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1736 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 1737 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1738 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 1739 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 1740 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 1741 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 1742 [ TYPE-II RESIDENCES Single Storey, 1UNIT. ] 1743 Earth Work 1744 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1745 All kinds of soil 1746 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 1747 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil 1748 Supplying and filling in plinth with sand under floors, including watering, ramming ,consolidating and dressing complete. 1749 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1750 Concrete Work 1751 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneIII)derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 1752 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 1753 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1754 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 1755 Brick edging in full brick width and half brick depth including excavation refilling and disposal of surplus earth lead upto 50 metres. With common burnt clayF.P.S.(non modulur)bricks of class designation 75 1756 Reinforced Cement Concrete 1757 Centering and shuttering including strutting, propping etc. and removal of form for all heights 1758 Foundations, footings, bases of columns, etc. for mass concrete. 1759 Suspended floors, roofs, landings, balconies and access platform. 1760 Lintels, beams, plinth beams, girders, bressumers 1761 Columns,Pillars, Piers, Abutments, Posts and Struts. 1762 Edges of slabs and breaks in floors and walls Under 20 cm wide. 1763 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 1764 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 1765 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 1766 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of theminimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1767 All works upto plinth level 1768 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 1769 (i) R.C.C. work in Footing 1770 (ii) R.C.C. work in Beam 1771 (iii) R.C.C. work in Columns 1772 All works above plinth level upto floor V level 1773 Concrete of M25 grade with minimum cement content of 330 kg /cum 1774 (i) R.C.C. work in Lintel 1775 (ii) R.C.C. work in Beam 1776 (iii) R.C.C. work in Columns 1777 (iv) R.C.C. work in Slab 1778 Masonry Work 1779 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : cement mortar 1:4 (1 cement : 4 coarse sand) 1780 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 1781 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) 1782 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1783 Cladding Work 1784 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1785 Granite stone slab colour black, Cherry/Ruby red 1786 Area of slab upto 0.50 sqm 1787 Area of slab over 0.50 sqm 1788 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 1789 Granite work 1790 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 1791 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1792 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1793 Wood and PVC Work 1794 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI markedStainless Steel butt hinges with necessary screws 1795 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1796 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 1797 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 1798 300 mm weighing not less than 200 gms 1799 250 mm weighing not less than 150 gms 1800 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 1801 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 1802 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 1803 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 1804 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1805 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1806 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1807 300 x 10mm 1808 150 x 10mm 1809 Steel Work 1810 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1811 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1812 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1813 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 1814 Flooring 1815 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 1816 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1817 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 1818 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm 1819 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm 1820 Finishing 1821 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 1822 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 1823 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 1824 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 1825 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 1826 Steel Painting:Applying priming coat 1827 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1828 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 1829 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: 1830 Two or more coats on new work. 1831 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1832 Water Proofing 1833 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1834 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 1835 PLUMBING INTERNAL ESTIMATE (Type- 2 Single unit) 1836 Sub Head– I Sanitary Installation 1837 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 1838 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 1839 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1840 W.C. pan with ISI marked white solid plastic seat and lid 1841 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 1842 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 1843 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1844 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 1845 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 1846 Providing and fixing toilet paper holder : 1847 C.P. brass 1848 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 1849 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 1850 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 1851 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 1852 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 1853 Kitchen sink with drain board 1854 510x1040 mm bowl depth 250mm 1855 Kitchen sink without drain board 1856 610x460 mm bowl depth 200 mm 1857 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 1858 Size 450x300x150 mm 1859 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 1860 Flexible pipe 1861 40 mm dia 1862 Providing and fixing soil, waste and vent pipes : 1863 100 mm dia 1864 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 1865 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1866 100 mm 1867 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 1868 Providing and fixing plain bend of required degree. 1869 100 mm 1870 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1871 Providing and fixing heel rest sanitary bend 1872 100 mm dia 1873 Sand cast iron S&S as per IS - 3989 1874 Providing and fixing double equal plain junction of required degree 1875 100x100x100x100 mm 1876 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1877 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1878 100x100x100 mm 1879 sand cast Iron S&S as per IS: 3989 1880 Providing and fixing single equal plain junction of required degree 1881 100x100x100 mm 1882 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1883 Providing and fixing terminal guard: 1884 100 mm 1885 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 1886 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 1887 100 mm 1888 S S 304 grade coupling with EPDM rubber gasket 1889 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 1890 100 mm 1891 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1892 100 mm diameter pipe 1893 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 1894 100 mm diameter pipe 1895 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1896 32 mm dia. nominal bore 1897 40 mm dia. nominal bore 1898 50 mm dia. nominal bore 1899 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1900 100 mm inlet and 100 mm outlet 1901 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 1902 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 1903 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 1904 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 1905 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 1906 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 1907 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 1908 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 1909 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 1910 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1911 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1912 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm dia 1913 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1914 Coupler 1915 110 mm 1916 Single tee with door 1917 110x110x110 mm 1918 Bend 87.5° 1919 110 mm 1920 Shoe (Plain) 1921 110 mm Shoe 1922 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1923 110 mm 1924 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 1925 110 mm outer dia 1926 50 mm outer dia 1927 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 1928 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 1929 Sub Head– II Water Supply 1930 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 1931 Internal work – Exposed on wall. 1932 20 mm nominal outer dia Pipes 1933 25 mm nominal outer dia Pipes 1934 32 mm nominal outer dia Pipes 1935 40 mm nominal outer dia Pipes 1936 50 mm nominal outer dia Pipes 1937 65 mm nominal outer dia Pipes 1938 80 mm nominal outer dia Pipes 1939 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1940 Concealed including cutting chases and making good the wall etc. 1941 15 mm nominal outer dia Pipes 1942 20 mm nominal outer dia Pipes 1943 25 mm nominal outer dia Pipes 1944 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1945 20 mm dia. nominal bore 1946 25 mm dia. nominal bore 1947 32 mm dia. nominal bore 1948 40 mm dia. nominal bore 1949 50 mm dia. nominal bore 1950 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1951 25 mm nominal bore 1952 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 1953 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 1954 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1955 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1956 15 mm nominal bore 1957 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1958 15 mm nominal bore 1959 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1960 15mm nominal bore 1961 Providing and fixing uplasticised PVC connection pipe with brass unions : 1962 45 cm length 1963 15 mm nominal bore 1964 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 1965 150 mm diameter 1966 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 1967 (a) 15 mm nominal dia 1968 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 1969 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 1970 upto 50 mm dia. nominal bore 1971 SUBHEAD– III Drainage 1972 Supply and fixing HDPE double wall corrugated ( DWC ) I.S 16098( Part - 2 ) 3013 for soil / waste pipe under ground drainage system withjointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete. 1973 150 mm diameter 1974 200 mm diameter 1975 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brickmasonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design : 1976 180x150 mm size P type 1977 With fly ash bricks (non modular) bricks of class designation 7.5 1978 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1979 150 mm dia. R.C.C. pipe 1980 250 mm dia. R.C.C. pipe 1981 300 mm dia. R.C.C. pipe 1982 Constructing brick masonry manholein cement mortar 1:4 (1 cement :4 coarse sand)with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size )inside plastering12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cementcomplete as per standard design . 1983 inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg ) 1984 with common brunt clay FPS ( non modular )bricks of class designation 7.5 1985 Extra depth formanhole 90x80 cm 1986 With FPSbricks class designation 7.5 1987 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequeringesides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having manufacture’s permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1988 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 1989 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1990 ELECTRICAL Works TYPE-2Single unit 1991 SUB HEAD - I: CIRCUIT CUM POINT WIRING 1992 SWITCH CONTROL LIGHT POINTS 1993 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1994 Group C 1995 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 1996 Group C 1997 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 1998 Group C 1999 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 2000 Group C 2001 MCB CONTROL LIGHT POINTS 2002 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 2003 Primary point controlled by one MCB. 2004 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 2005 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 2006 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2007 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 2008 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2009 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 2010 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 2011 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 2012 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 2013 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 2014 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 2015 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 2016 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2017 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2018 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 2019 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 2020 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2021 Telephone socket outlet 2022 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2023 1 or 2 Module (75mmX75mm) 2024 6 module (78mm X 205 mm X 50 mm) 2025 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2026 3 pin , 5/6 amps socket outlet 2027 5/6 amps switch 2028 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2029 25 mm 2030 32 mm 2031 SUBHEAD -II - FITTINGS & FIXTURES 2032 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 2033 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 2034 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 2035 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 2036 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 2037 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 2038 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 2039 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 2040 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 2041 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 2042 SUBHEAD - III - DISTRIBUTION BOARDS 2043 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2044 6 way, Double door 2045 8 way, Double door 2046 12 way, Double door 2047 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 2048 4 way (4 + 12), Double door 2049 6 way (4 + 18), Double door 2050 8 way (4 + 24), Double door 2051 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2052 12 way (4 + 36), Double door 2053 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2054 Single Pole 2055 Single Pole Neutral 2056 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2057 40 A 2058 63 A 2059 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2060 25 A 2061 40 A 2062 63 A 2063 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2064 25 A 2065 40 A 2066 63 A 2067 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 2068 SUB HEAD-IV , LIGHTNING CONDUCTOR 2069 LIGHTNING CONDUCTOR 2070 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 2071 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 2072 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2073 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 2074 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 2075 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 2076 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 2077 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 2078 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 2079 [GUEST HOUSE ] 2080 Earth Work 2081 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2082 All kinds of soil 2083 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 2084 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 2085 Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. 2086 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 2087 Concrete Work 2088 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 2089 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 2090 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 2091 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth. 2092 Brick edging in full brick width and half brick depth including excavation refilling and disposal of surplus earth lead upto 50 metres. With common burnt clayF.P.S.(non modulur)bricks of class designation 75 2093 Reinforced Cement Concrete 2094 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 2095 Foundations, footings, bases of columns, etc. for mass concrete. 2096 Suspended floors, roofs, landings, balconies and access platform. 2097 Lintels, beams, plinth beams, girders, bressumers 2098 Columns,Pillars, Piers, Abutments, Posts and Struts. 2099 Edges of slabs and breaks in floors and walls Under 20 cm wide. 2100 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 2101 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 2102 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 2103 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 2104 All works upto plinth level 2105 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 2106 (i) R.C.C. work in Footing 2107 (ii) R.C.C. work in Beam 2108 (iii) R.C.C. work in Columns 2109 All works above plinth level upto floor V level 2110 Concrete of M25 grade with minimum cementcontent of 330 kg /cum 2111 (i) R.C.C. work in Lintel 2112 (ii) R.C.C. work in Beam 2113 (iii) R.C.C. work in Columns 2114 (iv) R.C.C. work in Slab 2115 Masonry Work 2116 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 2117 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 2118 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V levelin : 2119 Cement mortar 1:6 (1 cement : 6 coarse sand) 2120 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 2121 Cladding Work 2122 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointinwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 2123 Wood and PVC Work 2124 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 2125 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 2126 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 2127 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 2128 300 mm weighing not less than 200 gms 2129 250 mm weighing not less than 150 gms 2130 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 2131 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous finecellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven selftapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as permanufacturers specification and direction of Engineer-in-charge. 2132 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 2133 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size, Kiln seasoned and chemically treated hollock wood 2134 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading 2135 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 2136 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2137 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2138 300 x 10mm 2139 150 x 10mm 2140 Steel Work 2141 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2142 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 2143 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2144 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 2145 Flooring 2146 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 2147 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 2148 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet forplacing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish ofsize of Tile 600 x 600 mm 2149 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. 2150 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 2151 Finishing 2152 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) 2153 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 2154 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 2155 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 2156 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 2157 Applying priming coat: 2158 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 2159 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 2160 Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade: 2161 Two or more coats on new work. 2162 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2163 Water Proofing 2164 Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 2165 Providing and laying brick tiles over mumty roofs, grouted with cementmortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 2166 PLUMBING INTERNAL ESTIMATE (Guest House ) 2167 Sub Head– I Sanitary Installation 2168 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. 2169 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 2170 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 2171 W.C. pan with ISI marked white solid plastic seat and lid 2172 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 2173 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification anddirection of Engineer-in-charge. 2174 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 2175 White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps 2176 Providing and fixingwhite vitreous china wash basin under counter basin, with C.I. concealed type brackets fixed to walls with GI rag bolts or approved fasteners etc., including 32 mm CP brass waste coupling, includingpainting of fittings and brackets, cutting and making good the walls wherever required all complete (Granite counter top will be measured and paid separately under relevent item): as per approved make and decision of engineer-in-charge 2177 Providing and fixing toilet paper holder : 2178 C.P. brass 2179 ProvidingandfixingCPbrassauto closing system basin pillartap / hand washofJaquar PRS - 001 or EquivalentasapprovedbyEngineer-In Charge 2180 ProvidingandfixingCPbrasssingle lever basin mixerwithout popowith 450mm long braided hose (connection pipe)basin pillartapofJaquar LYR-38001B or EquivalentasapprovedbyEngineer-In Charge. 2181 Providing and fixing 32mm C.P brass bottle Trap of approved quality & make as per the direction of engineer-in-incharge. 2182 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 2183 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever required : 2184 Kitchen sink with drain board 2185 510x1040 mm bowl depth 250mm 2186 Kitchen sink without drain board 2187 610x460 mm bowl depth 200 mm 2188 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 2189 Size 450x300x150 mm 2190 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 2191 Flexible pipe 2192 40 mm dia 2193 Providing and fixing soil, waste and vent pipes : 2194 100 mm dia 2195 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 2196 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 2197 100 mm 2198 Hubless centrifugally cast (spun) iron epoxy coated inside & outside I.S. 15905 2199 Providing and fixing plain bend of required degree. 2200 100 mm 2201 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 2202 Providing and fixing heel rest sanitary bend 2203 100 mm dia 2204 Sand cast iron S&S as per IS - 3989 2205 Providing and fixing double equal plain junction of required degree 2206 100x100x100x100 mm 2207 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 2208 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 2209 100x100x100 mm 2210 sand cast Iron S&S as per IS: 3989 2211 Providing and fixing single equal plain junction of required degree 2212 100x100x100 mm 2213 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 2214 Providing and fixing terminal guard: 2215 100 mm 2216 Hubless centrifugally cast (spun) iron pipe epoxy inside & outsideIS: 15905 2217 Providingand fixing shielded coupling for Hubless centrifugally cast iron pipes 2218 100 mm 2219 S S 304 grade coupling with EPDM rubber gasket 2220 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 2221 100 mm 2222 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 2223 100 mm diameter pipe 2224 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 2225 100 mm diameter pipe 2226 Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 2227 32 mm dia. nominal bore 2228 40 mm dia. nominal bore 2229 50 mm dia. nominal bore 2230 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2231 100 mm inlet and 100 mm outlet 2232 Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 2233 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 Cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 2234 Providing & fixing in position GI 100x50 elbowfloor drainincluding cost of cutting and making good the walls and floors whereverrequired. 2235 Providingandfixing125mmdiaS/S grating(withorwithouthole)for floor or Nahani trap. 2236 Providing and fixing soap dish holderfrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1131N & Equivalent 2237 Providing and fixing soap dispenser with glass bottlefrom wall of standard shape withfittings of approved quality with all complete. Make Jaquar - ACN-1135N & Equivalent 2238 Providing & fixing600 mm towel rail long stanless steel from wall face with concealedfittings arrangement of approved quality with all complete. Make Jaquar - CAN-1111SM 2239 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 2240 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2241 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 2242 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 2243 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 2244 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2245 Coupler 2246 110 mm 2247 Single tee with door 2248 110x110x110 mm 2249 Bend 87.5° 2250 110 mm 2251 Shoe (Plain) 2252 110 mm Shoe 2253 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 2254 110 mm 2255 Supplying and fixingofHDPE pipe (PE grade 63 - PN-8 ) confirming to IS 14333-1996chemical waste pipes jointed with rubber ring with good quality lubricantwithfittingsinclussive of allnecessaryspecialslike bends, tees, offsets,junctions etc laid under floor/under ceiling/on walls with suitable clamps and specialscuring, necessary chasing, jointing and restoring to original conditions, testing etc. including all other incidental chargesetc.complete for successful completion of work as per specifications, and asdirected by Engineer -in- Charge. 2256 110 mm outer dia 2257 50 mm outer dia 2258 Providing & fixing in position upvc Por S trap of self cleaning design offollowingsizesfor the embedded areasMaking proper connection withchemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 2259 Providing & Fixingwater cooler wth stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . 2260 Sub Head– II Water Supply 2261 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 2262 Internal work – Exposed on wall. 2263 20 mm nominal outer dia Pipes 2264 25 mm nominal outer dia Pipes 2265 32 mm nominal outer dia Pipes 2266 40 mm nominal outer dia Pipes 2267 50 mm nominal outer dia Pipes 2268 65 mm nominal outer dia Pipes 2269 80 mm nominal outer dia Pipes 2270 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2271 Concealed including cutting chases and making good the wall etc. 2272 15 mm nominal outer dia Pipes 2273 20 mm nominal outer dia Pipes 2274 25 mm nominal outer dia Pipes 2275 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2276 20 mm dia. nominal bore 2277 25 mm dia. nominal bore 2278 32 mm dia. nominal bore 2279 40 mm dia. nominal bore 2280 50 mm dia. nominal bore 2281 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2282 25 mm nominal bore 2283 Providing and fixing hand held ablution fitting (health faucet) with 1.2 meter long flexible tube and wall hook, all complete approved engineer-in-charge 2284 Supply and fixing of 15mm CP brass 2 -Way Bib Cock with wall flange and suitable length CP brass extension pipe all of approved engineer-in-charge 2285 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 2286 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 2287 15 mm nominal bore 2288 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 2289 15 mm nominal bore 2290 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 2291 15mm nominal bore 2292 Providing and fixing uplasticised PVC connection pipe with brass unions : 2293 45 cm length 2294 15 mm nominal bore 2295 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 2296 150 mm diameter 2297 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 2298 (a) 15 mm nominal dia 2299 Providing , Fixing, testing and commissioning of CP Brass 150 mmx 150 mmShower head with wall flange with all accessories as required andmaking good the walls wherever required. ( MAKE-JAQUAR -Model No- OHS-35495 or EQUIVALENT.) 2300 Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor withstainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect. 2301 upto 50 mm dia. nominal bore 2302 ELECTRICAL WorksGUEST HOUSE 2303 SUB HEAD - I: CIRCUIT CUM POINT WIRING 2304 SWITCH CONTROL LIGHT POINTS 2305 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2306 Group C 2307 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 2308 Group C 2309 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 2310 Group C 2311 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 2312 Group C 2313 MCB CONTROL LIGHT POINTS 2314 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 2315 Primary point controlled by one MCB. 2316 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 2317 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 2318 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2319 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2320 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 2321 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 2322 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 2323 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 2324 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 2325 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2326 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2327 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 2328 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 2329 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2330 Telephone socket outlet 2331 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2332 1 or 2 Module (75mmX75mm) 2333 6 module (78mm X 205 mm X 50 mm) 2334 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2335 3 pin , 5/6 amps socket outlet 2336 5/6 amps switch 2337 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2338 25 mm 2339 32 mm 2340 SUBHEAD -II - FITTINGS & FIXTURES 2341 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 2342 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 2343 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 2344 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 2345 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 2346 Supply, Installation, Testing and Commissioning of150 W CHANDELIER 2347 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 2348 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 2349 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 2350 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 2351 SUBHEAD - III - DISTRIBUTION BOARDS 2352 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 2353 6 way (4 + 18), Double door 2354 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2355 12 way (4 + 36), Double door 2356 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2357 Single Pole 2358 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2359 63 A 2360 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2361 63 A 2362 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 2363 SUB HEAD-IV , LIGHTNING CONDUCTOR 2364 LIGHTNING CONDUCTOR 2365 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 2366 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 2367 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2368 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 2369 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 2370 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 2371 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 2372 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 2373 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 2374 CUTTING & FILLING 2375 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2376 Ordinary rock 2377 QUANTITY OF CUTTING (A)@100% 2378 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2379 QUANTITY OF FILLING (B)@100% 2380 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 2381 QUANTITY OF FILLING (B-A) 2382 FOOTPATH 2.00 MT. WIDE 2383 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge 2384 all kinds of soil 2385 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level. 2386 1:5:10 (1 cement : 5 course bound: 10 graded stone aggregate 40mm nominal size) 2387 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 2388 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 2389 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 2390 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 2391 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 2392 Filling available excavated earth (excluding rock) in trenches, plinth, sides ofoundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2393 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 2394 Foundations, footings, bases of columns, etc. for mass concrete. 2395 BITUMINUS ROAD FOR 3.5 MTR WIDE 2396 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2397 all kinds of soil 2398 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level. 2399 1:5:10 (1 cement : 5 course bound: 10 graded stone aggregate 40mm nominal size) 2400 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 2401 Supplying and stacking at site.90 mm to 45 mm size stone aggregate 2402 Supplying and stacking at site63 mm to 45 mm size stone aggregate 2403 Laying, spreading and compacting stone aggregate of specified sizes to WBM pecifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required densi 2404 Laying, spreading and compacting stone aggregate of specified sizes to WBM pecifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required densi 2405 Supplying and stacking at siteStone screening 13.2 mm nominal size (Type A) 2406 Supplying and stacking at siteStone screening 11.2 mm nominal size (Type B) 2407 Supplying and stacking at siteRed bajri 2408 Supplying and stacking at siteMoorum 2409 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt 2410 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 2411 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 2412 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 2413 Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :On W.B.M. @ 0.75 Kg / sqm 2414 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete 2415 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 2416 STONE STEPS -1 2417 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.All kinds of soil 2418 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand ) 2419 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 2420 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2421 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 2422 on top 2423 Pointing on stone work with cement mortar 1:3 (1 cement : 3 finesand): 2424 Raised and cut pointing 2425 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 2426 all kinds soil 2427 In all kinds soil upto 1.5m to 3.0m. depth 2428 In all kinds soil upto 3.0m to 4.5m. depth 2429 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: 2430 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 2431 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 2432 Cement mortar 1:6 (1 cement : 6 coarse sand) 2433 Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) 2434 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 2435 Mild steel and Medium Tnsile steel bars. 2436 Centring and shuttering including struting , proping etc and removal of form for : 2437 Suspended floors, roofs, landings, balconies and access platform. 2438 Edges of slabs and breaks in floors and walls 2439 12 mm cement plaster on rough side of single or half brick wall mix 2440 1:6 (1 cement : 6 coarse sand) 2441 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 2442 H.D. -20- Circular shape 560mm internal diameter 2443 Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level. 2444 All types of soil 2445 300 mm dia 2446 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 2447 150 mm nominal size dia 2448 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2449 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2450 Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2451 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. 2452 DESILTING CHAMBER 2453 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 2454 all kinds soil 2455 In all kinds soil upto 1.5m to 3.0m. depth 2456 Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: 2457 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 2458 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 2459 Cement mortar 1:6 (1 cement : 6coarse sand) 2460 Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) 2461 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 2462 Mild steel and Medium Tnsile steel bars. 2463 Centring and shuttering including struting , proping etc and removal of form for : 2464 Suspended floors, roofs, landings, balconies and access platform. 2465 Edges of slabs and breaks in floors and walls 2466 Under 20 cm wide 2467 12 mm cement plaster on rough side of single or half brick wall mix 2468 1:6 (1 cement : 6 coarse sand) 2469 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 2470 With 20x20mm square bar 2471 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 2472 L D- 2.5 Rectangular shape 600x450mm internal dimensions . 2473 Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 75 in cement mortar 1:6(1 cement : 6 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 2474 Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2475 upto 1.5m depth 2476 all kinds soil 2477 In all kind of soil upto 1.5m to 3.0m. depth 2478 all kinds soil 2479 In all kind of soil upto 3.0m to 4.5m. depth 2480 all kinds soil 2481 In all kind of soil upto 4.5m to 6.0m. depth 2482 all kinds soil 2483 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 2484 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 2485 Cement mortar 1:6 (1 cement : 6 coarse sand) 2486 Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) 2487 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 2488 Mild steel and Medium Tnsile steel bars. 2489 Centring and shuttering including struting , proping etc and removal of form for : 2490 Suspended floors, roofs, landings, balconies and access platform. 2491 Edges of slabs and breaks in floors and walls 2492 Under 20 cm wide 2493 12 mm cement plaster on rough side of single or half brick wall mix 2494 1:6 (1 cement : 6 coarse sand) 2495 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 2496 HD-20- Circular shape 560mm internal diameter 2497 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. 2498 Rockey strata including Boulders (300 mm dia 2499 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 2500 150 mm nominal size dia 2501 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2502 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2503 Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2504 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. 2505 DESILTING CHAMBER 2506 Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2507 upto 1.5m depth 2508 all kinds soil 2509 upto 1.5m to 3.0m. depth 2510 all kinds soil 2511 upto 3.0m to 4.5m. depth 2512 all kinds soil 2513 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 2514 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 2515 Cement mortar 1:6 (1 cement : 6coarse sand) 2516 Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) 2517 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 2518 Mild steel and Medium Tnsile steel bars. 2519 Centring and shuttering including struting , proping etc and removal of form for : 2520 Suspended floors, roofs, landings, balconies and access platform. 2521 Edges of slabs and breaks in floors and walls 2522 Under 20 cm wide 2523 12 mm cement plaster on rough side of single or half brick wall mix 2524 1:6 (1 cement : 6 coarse sand) 2525 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 2526 With 20x20mm square bar 2527 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 2528 LD-2.5 Rectangular shape 600x450mm internal dimensions 2529 Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 75 in cement mortar 1:6 (1 cement : 6 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 2530 WATER SUPPLY 2531 SUB HEAD (I) :- EXTERNAL WATER SUPPLY PIPES AND FITTINGS 2532 DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY 2533 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 2534 External work 2535 20 mm dia nominal bore 2536 25 mm dia nominal bore 2537 32 mm dia nominal bore 2538 40 mm dia nominal bore 2539 50 mm dia nominal bore 2540 65 mm dia nominal bore 2541 80 mm dia nominal bore 2542 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 2543 20 mm diameter pipe 2544 25 mm diameter pipe 2545 32 mm diameter pipe 2546 40 mm diameter pipe 2547 50 mm diameter pipe 2548 65 mm diameter pipe 2549 80 mm diameter pipe 2550 Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work. 2551 20mm dia nominal bore 2552 25mm dia nominal bore 2553 32mm dia nominal bore 2554 40mm dia nominal bore 2555 50 mm diameter pipe 2556 65 mm diameter pipe 2557 80 mm diameter pipe 2558 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 2559 50 mm dia 2560 80 mm dia 2561 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2562 20 mm nominal bore 2563 25 mm nominal bore 2564 32 mm nominal bore 2565 40 mm nominal bore 2566 50 mm nominal bore 2567 65 mm nominal bore 2568 80 mm nominal bore 2569 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2570 Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work) 2571 25 mm nominal bore 2572 32 mm nominal bore 2573 40 mm nominal bore 2574 50 mm nominal bore 2575 65 mm nominal bore 2576 80 mm nominal bore 2577 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2578 LD- 2.5 2579 Rectangular shape 600*450 mm internal dimensions 2580 Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2581 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 2582 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2583 with common burnt clay F.P.S.(non module) brick of class designation 7.5 2584 SURFACE DRAIN (250X150 MM) 2585 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2586 all kinds of soil 2587 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2588 Qty. = 25% of them no 1 2589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 2590 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). 2591 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2592 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2593 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 2594 Foundations, footings, bases of columns, etc. for mass concrete 2595 Brick work with F.P.S. bricks of class designation 75 infoundation and plinth in : 2596 Cement mortar 1:6 (1 cement : 6 coarse sand) 2597 12 mm cement plaster finished with a floating coat of neat cement of mix : 2598 1:4 (1 cement: 4 fine sand) 2599 Hume pipe 2600 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2601 All kinds of soil 2602 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 2603 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2604 450 mm dia. R.C.C. pipe 2605 Providingandlayingcementconcrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 gradded stoneaggregate40 mm nominal size) alround S.W. Pipesincludingbed concrete as per standard design. 2606 450 mm diameter S.W.Pipe 2607 SUB HEAD (I) :- EXTERNAL SEWERAGE SYSTEM 2608 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m : 2609 All kinds of soil 2610 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 2611 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2612 150 mm dia. R.C.C. pipe 2613 250 mm diameter S.W. pipe 2614 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). 2615 150 mm diameter S.W.Pipe (626.90*0.35*0.10=21.94) 2616 250 mm diameter S.W. pipe (8.90*0.45*0.10=0.40) 2617 Constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 2618 Inside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 2619 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 2620 Extra for depth for manholes: 2621 size 90 X 80 cm 2622 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 2623 Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricksclass designation 75in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 2624 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 2625 with common burnt clay F.P.S.(non module) brick of class designation 7.5 2626 Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 2627 with common burnt clay F.P.S.(non module) brick of class designation 7.5 2628 Providing and fixing square mouthS. W. Gully trapclass SP-1 complete with C.I. gratingbrickmasonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 2629 180 x 150 mm. size P type 2630 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 2631 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 2632 With 20x20 mm square bar 2633 ESTIMATE OF ELECTRICAL WORKS 2634 SUBHEAD - I - MAIN BOARDS 2635 Supplying, installing, testing & commissioning of following type compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of suitable size 4 strip Al. Busbar complete with interconnection providing Lugs, inter-earthing, painting etc. i/c providing & fixing below noted accessories: 2636 Receiving,unloading,storing, handling, installation, testing and commissioning of following MV Switchboards complete as required and as per site condition and dimension of all panels shall be carried out as per the attachad sld 2637 FEEDER PILLAR 2638 Design, Manufacturing, supplying, fixing in position, testing and commissioning of the following front operated front access 2mm thick CRCA steel enclosure free standing, water, dust and vermin proof outdoor type Feeder pillars with IP-55 protection hinged and lockable doors complete with interconnections copper crimping lugs, brass glands bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system . The panels fault withstanding capacity shall be of 25 MVA at 415 volts. All live accessories part shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be of colure coded with Heat shrinkable PVC insulated sleeves. 2639 FEEDER PILLAR-3 FOR VICE PRINCIPLE, BOYS DORM. & GIRLS DORM. 2640 INCOMER 2641 1 No. 200A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit. 2642 1 No. Digital multifunction meter(V+A+Hz) with a set of cast resin CTs 200/5A. 2643 1 Set of Phase indicating lamp with MCB 2644 BUS BARS-I : 2645 250A TPN bus bars of aluminium alloy. 2646 For emergency supply 2647 1 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit. 2648 1 Set of On indicating lamp with MCB 2649 BUS BARS-II : 2650 100A TPN bus bars of aluminium alloy. 2651 OUT GOING BUS-I : 2652 3 Nos. 63A 415V, 4P MCB of 10kA . 2653 1 No. 100A 415V, 4P MCCB of 10kA . 2654 1 No. MCB Space. 2655 OUT GOING BUS-II : 2656 2 Nos. 63A 415V, 4P MCB of 10kA . 2657 1 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch . 2658 2 Nos. 25A 415V, 4P MCB of 10kA . 2659 1 No. MCB Space. 2660 FEEDER PILLAR-4 FOR GUEST HOUSE, TYPE-III (G+2), TYPE-II (G+2) & TYPE II (SS). 2661 INCOMER 2662 1 No. 250A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit. 2663 1 No. Digital multifunction meter(V+A+Hz) with a set of cast resin CTs 250/5A. 2664 1 Set of Phase indicating lamp with MCB 2665 BUS BARS-I : 2666 300A TPN bus bars of aluminium alloy. 2667 For emergency supply 2668 1 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit. 2669 1 Set of On indicating lamp with MCB 2670 BUS BARS-II : 2671 100A TPN bus bars of aluminium alloy. 2672 OUT GOING BUS-I : 2673 8 Nos. 63A 415V, 4P MCCB of 15kA . 2674 1 No. 100A 415V, 4P MCCB of 15kA . 2675 1 No. MCB Space. 2676 OUT GOING BUS-II : 2677 2 Nos. 63A 415V, 4P MCB of 10kA . 2678 1 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch . 2679 2 Nos. 25A 415V, 4P MCB of 10kA . 2680 1 No. MCB Space. 2681 METER BOARDS 2682 Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CTs, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingMCBs MCCBs and kWh meters complete as required. 2683 METER BOARDS - 0.375 BOYS DORMITORY & 0.375 GIRLS DORMITORY 2684 1 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp. 2685 BUS BARS: 2686 100A TPN bus bars of aluminium alloy. 2687 OUT GOING: 2688 2 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement. 2689 7 Nos. 40A DP MCB of 10kA. 2690 METER BOARDS - VICE PRINCIPAL 2691 1 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp. 2692 BUS BARS: 2693 100A TPN bus bars of aluminium alloy. 2694 OUT GOING: 2695 1 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement. 2696 1 No. 40A DP MCB of 10kA. 2697 METER BOARDS - GUEST HOUSE & TYPE - (SINGLE STOREY) 2698 1 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp. 2699 BUS BARS: 2700 100A TPN bus bars of aluminium alloy. 2701 OUT GOING: 2702 2 Nos. 40A TPN MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement. 2703 1 No. 40A DP MCB of 10kA. 2704 METER BOARDS - TYPE-III RESIDENCE (G+2) 2705 1 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp. 2706 BUS BARS: 2707 100A TPN bus bars of aluminium alloy. 2708 OUT GOING: 2709 4 Nos. 40A TPN MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement. 2710 1 No. 40A DP MCB of 10kA. 2711 METER BOARDS -TYPE-II RESIDENCE (G+2) 2712 1 Nos. 100A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp. 2713 BUS BARS: 2714 125A TPN bus bars of aluminium alloy. 2715 OUT GOING: 2716 2 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement. 2717 7 Nos. 40A DP MCB of 10kA. 2718 SUBHEAD - II - EARTHING 2719 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2720 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2721 Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (CI heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 2722 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. 2723 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 2 nos used for 50 x 5 for the Neutral earthing of euipments ) 2724 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 2725 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. 2726 Supply and laying medium class GI pipe under road/paved areas/wall crossing etc. including earth excavations refilling, ramming and making good as approved. 2727 150 mm dia GI pipe Class B 2728 SUBHEAD - III - SUPPLYING & LAYING OF CABLE 2729 L.T. CABLES 2730 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 2731 63 mm dia (OD-63 mm & ID-51 mm nominal) 2732 90 mm dia (OD-90 mm & ID-76 mm nominal) 2733 120 mm dia (OD-120 mm & ID-103 mm nominal) 2734 160 mm dia (OD-160 mm & ID-135 mm nominal) 2735 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 2736 90 mm dia (OD-90 mm & ID-76 mm nominal) 2737 120 mm dia (OD-120 mm & ID-103 mm nominal) 2738 160 mm dia (OD-160 mm & ID-135 mm nominal) 2739 Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. 2740 Upto 35 sq.mm 2741 Above 35 sq. mm and upto 95 sq. mm 2742 Above 95 sq.mm and upto 185 sq.mm 2743 Above 185 sq.mm and upto 400 sq.mm 2744 Supply of following sizes of XLPE insulatedAluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 2745 6 sq. mm 4 core 2746 4 X 16 sq. mm (28mm 2747 3½ X 25 sq. mm (28mm) 2748 3½ X 35 sq. mm (32mm) 2749 3½ X 50 sq. mm (35mm) 2750 3½ X 150 sq. mm (50mm) 2751 3½ X 185 sq. mm (57mm) 2752 3½ X 240 sq. mm (62mm) 2753 3½ X 300 sq. mm (70mm) 2754 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required. 2755 4 X 6 sq. mm (28mm 2756 4 X 16 sq. mm (28mm 2757 3½ X 25 sq. mm (28mm) 2758 3½ X 35 sq. mm (32mm) 2759 3½ X 50 sq. mm (35mm) 2760 3½ X 150 sq. mm (50mm) 2761 3½ X 185 sq. mm (57mm) 2762 3½ X 240 sq. mm (62mm) 2763 3½ X 300 sq. mm (70mm) 2764 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 2765 150 mm dia 2766 250 mm dia 2767 Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not morethan 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 2768 150 mm width X 50 mm depth X 1.6 mm thickness 2769 300 mm width X 50 mm depth X 1.6 mm thickness 2770 450 mm width X 50 mm depth X 2 mm thickness 2771 Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays bends with perforationnot more than 17.5%,, joined with connectors, suspended fromthe ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required. 2772 150 mm width X 50 mm depth X 1.6 mm thickness 2773 300 mm width X 50 mm depth X 1.6 mm thickness 2774 450 mm width X 50 mm depth X 2 mm thickness 2775 Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays Tee with perforation notmore than 17.5%, joined with connectors, suspended from theceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required. 2776 150 mm width X 50 mm depth X 1.6 mm thickness 2777 300 mm width X 50 mm depth X 1.6 mm thickness 2778 450 mm width X 50 mm depth X 2 mm thickness 2779 Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays Cross Member withperforation not more than 17.5%, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 2780 150 mm width X 50 mm depth X 1.6 mm thickness 2781 300 mm width X 50 mm depth X 1.6 mm thickness 2782 450 mm width X 50 mm depth X 2 mm thickness 2783 SUB HEAD -IV :EXTERNAL LIGHT 2784 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 2785 Above 6.5 metre and upto 8.0 metre 2786 Supplying, installation, testing and commissioning of 60W LED Street LightIP66 LED with High performance having system lumen output of minimum 9900 lumens, contemporary designed housing made of die-cast aluminium, with street optic LENS for uniform light distribution. PF better than 0.9, CRI better than 70 complete with all accessories. Wipro Cat No.: LR 02-102-XXX-57-G2 Street light 2787 Supplying, installation, testing and commissioning of 60W LEDSolar Street Light On 6 Meter GI octagonal Pole having Compact, Aesthetic, Eco friendly & modern integrated Solar street light in extruted Aluminum construction with high efficiency monocrystalline silicon photo voltaic panel, high efficacy SMD LED 6500K having secondary lens optics for street lighting distribution, high performance lithium battery, MPPT charge controller & Intelligent control module/sensor with higher reliability, long service life, suitable for easy & quick installation. Wipro Cat No.:LR 14-591-XXX-65-XX. 2788 Supply, testing & commissioning of 6.0 meter high G.Ioctagonal pole (Above Ground Level) with single/double arm as per requirement of suitable length with inbuilt junction box with 10A SP MCB, connectors for incoming/outgoing cable connection and 300mm x 300mm x 20 mm thick base plate and bracket (double arm/single arm whichever required) complete in all respect. 2789 Providing, installation of 200 x 150 x 125 mm polycarbonate weather proof (IP-55) junction box and SP MCB’s and terminal block. Supplying and laying cable through GI pipe upto junction box including excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixturecomplete. 2790 Supplying and laying cable through GI pipe upto junction box including excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixturecomplete. 2791 Supplying and fixing of high voltage insulation mat of class B having 11 KV dielectric strength, 1000mm width and thickness of 2.5mm ISI approved as required including cutting to required lengths. 2792 Supplying and fixing of high voltage insulation mat of class B having 1.1 KV dielectric strength, 1000mm width and thickness of 2.0 mm ISI approved as required including cutting to required lengths. 2793 Supplying of 11 KV hand gloves as required. 2794 Supplying of resuciation kit coomplete with instruction manual etc. as required. 2795 Supplying of fire bucket painted red with stand and approved quality conforming to IS:254/1974 2796 Supplying and Fixing of Powder Fire Extinguisher (Stored Pressure type)Capacity 06 Kg duly ISI marked conforming to IS: 15683:2006, with IS 14609, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge & suitable M.S. bracket as required. 2797 Supplying of first aid box as approved complete with standard kit as prescribed by Indian Red Cross. 2798 Supplying and fixing of shock treatment chart written in English and Local language duly framed in glass as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
29.
Housing Urban and Rular Development #9440737 Technical Bid
Construction Of Phase-B Works At Jawahar Navodaya Vidyalaya At Khunti ( Jharkhand ) -Name Of Work: 1 0.625 BoyS Dormitory With 3 Nos. Warden Residence ( G+2 ) 2 Civil Work 3 Earth Work 4 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil 5 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 7 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 8 Concrete Work 9 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 10 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 11 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 12 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 13 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation, Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 14 Reinforced Cement Concrete 15 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 16 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 17 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 18 Lintels, Beams, Plinth Beams, Girders, Bressumers 19 Columns, Pillars, Piers, Abutments, Posts And Struts. 20 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 22 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 23 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 24 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 25 All Works Upto Plinth Level 26 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 27 ( I ) R.C.C. Work In Footing 28 ( Ii ) R.C.C. Work In Beam 29 ( Iii ) R.C.C. Work In Columns 30 All Works Above Plinth Level Upto Floor V Level 31 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 32 ( I ) R.C.C. Work In Lintel 33 ( Ii ) R.C.C. Work In Beam 34 ( Iii ) R.C.C. Work In Columns 35 ( Iv ) R.C.C. Work In Slab 36 Expansion Joint Treatment 37 Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas That Commodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions. The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) . 38 Floor Joint Of 100 Mm Gap 39 Providing And Fixing Of Expansion Joint System Related With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints Systemsuitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimal Exposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) . 40 Wall Joint Of 100 Mm Gap 41 Providing And Fixing Of Expansion Joint System Of Approved Make And Manufacture For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates As Per Astm B221-02. The System Shall Be Such That It Provides Water Tight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed Toaccommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) 42 Roof Joint Of 100 Mm Gap 43 Masonry Work 44 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 45 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 46 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 47 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 48 Cladding Work 49 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 50 Granite Stone Slab Colour Black, Cherry / Ruby Red 51 Area Of Slab Upto 0.50 Sqm 52 Area Of Slab Over 0.50 Sqm 53 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 54 Granite Work 55 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 56 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 57 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 58 Wood And Pvc Work 59 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 60 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 61 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 62 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 63 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 64 300 Mm Weighing Not Less Than 200 Gms 65 250 Mm Weighing Not Less Than 150 Gms 66 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 67 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 68 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.5 Mm Thick 69 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size Kiln Seasoned And Chemically Treated Hollock Wood 70 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 71 Providing And Fixing 6Mm Thick Both Sides Pre-Laminated Cement Bonded Wood Particle Board As Per Is : 15786:2008 Of Approved Brand And Shade With Suitable Full Threaded Steel Screws Etc. On The Backing Of Racks, Drawer, Cupboard, Kitchen Cabinet Under Kitchen Counter Etc. All Complete As Per Direction Of Engineer In-Charge. 72 Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges ( Hydraulic Type ) Etc. Complete As Per Direction Of Engineer In-Charge. ( Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately ) 73 Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approvedbrand Boxes, Shelves, Racks, Almirah, Cupboard And Drawer Etc. Including Necessary Nails, Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 74 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 100 Mm For Kitchen Cabinets 75 Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges ( Hydraulic Type ) Of Approved Make / Brand To Cupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete As Perdirection Of Engineer-In-Charge 76 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 77 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 78 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 79 200 X 10Mm 80 150 X 10Mm 81 Steel Work 82 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 83 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 84 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 85 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. 86 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 87 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 88 Flooring 89 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 90 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Medium Shade Pigment Using 50% White Cement 50% Grey Cement 91 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 92 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 93 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600 X 600 Mm 94 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 95 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 96 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 97 P & Laying Cement Concrete 98 Finishing 99 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 100 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 101 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 102 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 103 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 104 Steel Painting:Applying Priming Coat: 105 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 106 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 107 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: Two Or More Coats On New Work. 108 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 109 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 110 Water Proofing 111 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 112 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 113 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tilesof Class Designation 10 114 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 115 2.1 Mtht. Boundary Wall 116 Plumbing Internal Estimate ( 0.625 Unit Boys Dormitory With 3 Nos Warden Residence ) 117 Sub Head– I Sanitary Installation 118 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 119 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 120 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 121 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 122 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 123 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 124 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 125 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 126 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 127 Providing And Fixing Toilet Paper Holder : 128 C.P. Brass 129 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 130 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 131 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 132 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 133 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 134 Kitchen Sink With Drain Board 135 510X1040 Mm Bowl Depth 250Mm 136 Kitchen Sink Without Drain Board 137 610X460 Mm Bowl Depth 200 Mm 138 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 139 Size 450X300x150 Mm 140 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 141 Flexible Pipe 142 40 Mm Dia 143 Providing And Fixing Soil, Waste And Vent Pipes : 144 100 Mm Dia 145 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 146 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 147 100 Mm 148 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 149 Providing And Fixing Plain Bend Of Required Degree. 150 100 Mm 151 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 152 Providing And Fixing Heel Rest Sanitary Bend 153 100 Mm Dia 154 Sand Cast Iron S&S As Per Is - 3989 155 Providing And Fixing Double Equal Plain Junction Of Required Degree 156 100X100x100x100 Mm 157 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 158 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 159 100X100x100 Mm 160 Sand Cast Iron S&S As Per Is: 3989 161 Providing And Fixing Single Equal Plain Junction Of Required Degree 162 100X100x100 Mm 163 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 164 Providing And Fixing Terminal Guard: 165 100 Mm 166 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 167 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 168 100 Mm 169 S S 304 Grade Coupling With Epdm Rubber Gasket 170 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 171 100 Mm 172 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 173 100 Mm Diameter Pipe 174 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 175 100 Mm Diameter Pipe 176 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 177 32 Mm Dia. Nominal Bore 178 40 Mm Dia. Nominal Bore 179 50 Mm Dia. Nominal Bore 180 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 181 100 Mm Inlet And 100 Mm Outlet 182 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 183 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 184 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 185 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 186 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 187 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 188 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 189 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 190 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 191 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 192 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 193 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 194 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 195 Coupler 196 110 Mm 197 Single Tee With Door 198 110X110x110 Mm 199 Bend 87.5° 200 110 Mm 201 Shoe ( Plain ) 202 110 Mm Shoe 203 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 204 110 Mm 205 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 206 110 Mm Outer Dia 207 50 Mm Outer Dia 208 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 209 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 210 Sub Head– Ii Water Supply 211 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 212 Internal Work – Exposed On Wall. 213 20 Mm Nominal Outer Dia Pipes 214 25 Mm Nominal Outer Dia Pipes 215 32 Mm Nominal Outer Dia Pipes 216 40 Mm Nominal Outer Dia Pipes 217 50 Mm Nominal Outer Dia Pipes 218 65 Mm Nominal Outer Dia Pipes 219 80 Mm Nominal Outer Dia Pipes 220 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 221 Concealed Including Cutting Chases And Making Good The Wall Etc. 222 15 Mm Nominal Outer Dia Pipes 223 20 Mm Nominal Outer Dia Pipes 224 25 Mm Nominal Outer Dia Pipes 225 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 226 20 Mm Dia. Nominal Bore 227 25 Mm Dia. Nominal Bore 228 32 Mm Dia. Nominal Bore 229 40 Mm Dia. Nominal Bore 230 50 Mm Dia. Nominal Bore 231 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 232 25 Mm Nominal Bore 233 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 234 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 235 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 236 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 237 15 Mm Nominal Bore 238 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 239 15 Mm Nominal Bore 240 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 241 15Mm Nominal Bore 242 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 243 45 Cm Length 244 15 Mm Nominal Bore 245 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 246 150 Mm Diameter 247 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 248 ( A ) 15 Mm Nominal Dia 249 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 250 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 251 Upto 50 Mm Dia. Nominal Bore 252 Subhead– Iii Drainage 253 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 254 150 Mm Diameter 255 200 Mm Diameter 256 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 257 180X150 Mm Size P Type 258 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 259 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 260 150 Mm Dia. R.C.C. Pipe 261 250 Mm Dia. R.C.C. Pipe 262 300 Mm Dia. R.C.C. Pipe 263 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 264 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 265 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 266 Extra Depth Formanhole 90X80 Cm 267 With Fpsbricks Class Designation 7.5 268 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 269 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 270 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 271 Electrical Works 0.625Boys Dormitory With 3 Nos. Warden Residence 272 Sub Head - I: Circuit Cum Point Wiring 273 Switch Control Light Points 274 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 275 Group C 276 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 277 Group C 278 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 279 Group C 280 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 281 Group C 282 Mcb Control Light Points 283 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 284 Primary Point Controlled By One Mcb. 285 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 286 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 287 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 288 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 289 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 290 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 291 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 292 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 293 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 294 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 295 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 296 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 297 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 298 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 299 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 300 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 301 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 302 Telephone Socket Outlet 303 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 304 1 Or 2 Module ( 75Mmx75mm ) 305 6 Module ( 78Mm X 205 Mm X 50 Mm ) 306 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 307 3 Pin , 5 / 6 Amps Socket Outlet 308 5 / 6 Amps Switch 309 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 310 25 Mm 311 32 Mm 312 Subhead -Ii - Fittings & Fixtures 313 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 314 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 315 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 316 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 317 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 318 Supply, Installation, Testing And Commissioning Of150 W Chandelier 319 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 320 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 321 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 322 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 323 Subhead - Iii - Distribution Boards 324 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 325 6 Way, Double Door 326 8 Way, Double Door 327 12 Way, Double Door 328 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 329 4 Way ( 4 + 12 ) , Double Door 330 6 Way ( 4 + 18 ) , Double Door 331 8 Way ( 4 + 24 ) , Double Door 332 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 333 12 Way ( 4 + 36 ) , Double Door 334 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 335 Single Pole 336 Single Pole Neutral 337 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 338 40 A 339 63 A 340 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 341 25 A 342 40 A 343 63 A 344 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 345 25 A 346 40 A 347 63 A 348 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 349 Sub Head-Iv , Lightning Conductor 350 Lightning Conductor 351 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 352 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 353 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 354 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 355 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 356 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 357 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 358 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 359 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 360 0.375 GirlS Dormitory With 3 Nos. Warden Residence ( G+2 ) 361 Earth Work 362 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil 363 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 364 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 365 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 366 Concrete Work 367 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 368 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 369 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 370 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 371 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation, Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 372 Reinforced Cement Concrete 373 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 374 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 375 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 376 Lintels, Beams, Plinth Beams, Girders, Bressumers 377 Columns, Pillars, Piers, Abutments, Posts And Struts. 378 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 379 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 380 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 381 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 382 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 383 All Works Upto Plinth Level 384 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 385 ( I ) R.C.C. Work In Footing 386 ( Ii ) R.C.C. Work In Beam 387 ( Iii ) R.C.C. Work In Columns 388 All Works Above Plinth Level Upto Floor V Level 389 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 390 ( I ) R.C.C. Work In Lintel 391 ( Ii ) R.C.C. Work In Beam 392 ( Iii ) R.C.C. Work In Columns 393 ( Iv ) R.C.C. Work In Slab 394 Expansion Joint Treatment 395 Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas That Commodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions. The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) . 396 Floor Joint Of 100 Mm Gap 397 Providing And Fixing Of Expansion Joint System Related With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints Systemsuitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimal Exposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) . 398 Wall Joint Of 100 Mm Gap 399 Providing And Fixing Of Expansion Joint System Of Approved Make And Manufacture For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates As Per Astm B221-02. The System Shall Be Such That It Provides Water Tight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To 400 Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) 401 Roof Joint Of 100 Mm Gap 402 Masonry Work 403 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 404 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 405 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 406 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 407 Cladding Work 408 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 409 Granite Stone Slab Colour Black, Cherry / Ruby Red 410 Area Of Slab Upto 0.50 Sqm 411 Area Of Slab Over 0.50 Sqm 412 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 413 Granite Work 414 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 415 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 416 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 417 Wood And Pvc Work 418 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 419 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 420 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 421 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 422 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 423 300 Mm Weighing Not Less Than 200 Gms 424 250 Mm Weighing Not Less Than 150 Gms 425 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 426 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 427 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality.1.5 Mm Thick 428 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size Kiln Seasoned And Chemically Treated Hollock Wood 429 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 430 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 431 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 432 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 433 200 X 10Mm 434 150 X 10Mm 435 Steel Work 436 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 437 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 438 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 439 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. 440 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 441 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 442 Flooring 443 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 444 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Medium Shade Pigment Using 50% White Cement 50% Grey Cement 445 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 446 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 447 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Requiredthickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600 X 600 Mm 448 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 449 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 450 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 451 P & Laying Cement Concrete 452 Finishing 453 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 454 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 455 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 456 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 457 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 458 Steel Painting:Applying Priming Coat: 459 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 460 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 461 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: Two Or More Coats On New Work. 462 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 463 Water Proofing 464 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 465 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 466 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tilesof Class Designation 10 467 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 468 2.1 Mtht. Boundary Wall 469 Plumbing Internal Estimate ( 0.375 Unit Girls Dormitory With 3 Nos Warden Residence ) 470 Sub Head– I Sanitary Installation 471 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 472 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 473 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 474 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 475 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 476 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 477 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 478 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 479 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 480 Providing And Fixing Toilet Paper Holder : 481 C.P. Brass 482 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 483 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 484 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 485 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 486 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 487 Kitchen Sink With Drain Board 488 510X1040 Mm Bowl Depth 250Mm 489 Kitchen Sink Without Drain Board 490 610X460 Mm Bowl Depth 200 Mm 491 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 492 Size 450X300x150 Mm 493 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 494 Flexible Pipe 495 40 Mm Dia 496 Providing And Fixing Soil, Waste And Vent Pipes : 497 100 Mm Dia 498 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 499 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 500 100 Mm 501 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 502 Providing And Fixing Plain Bend Of Required Degree. 503 100 Mm 504 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 505 Providing And Fixing Heel Rest Sanitary Bend 506 100 Mm Dia 507 Sand Cast Iron S&S As Per Is - 3989 508 Providing And Fixing Double Equal Plain Junction Of Required Degree 509 100X100x100x100 Mm 510 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 511 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 512 100X100x100 Mm 513 Sand Cast Iron S&S As Per Is: 3989 514 Providing And Fixing Single Equal Plain Junction Of Required Degree 515 100X100x100 Mm 516 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 517 Providing And Fixing Terminal Guard: 518 100 Mm 519 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 520 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 521 100 Mm 522 S S 304 Grade Coupling With Epdm Rubber Gasket 523 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 524 100 Mm 525 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 526 100 Mm Diameter Pipe 527 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 528 100 Mm Diameter Pipe 529 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 530 32 Mm Dia. Nominal Bore 531 40 Mm Dia. Nominal Bore 532 50 Mm Dia. Nominal Bore 533 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 534 100 Mm Inlet And 100 Mm Outlet 535 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 536 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 537 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 538 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 539 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 540 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 541 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 542 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 543 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 544 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 545 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 546 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 547 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 548 Coupler 549 110 Mm 550 Single Tee With Door 551 110X110x110 Mm 552 Bend 87.5° 553 110 Mm 554 Shoe ( Plain ) 555 110 Mm Shoe 556 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 557 110 Mm 558 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 559 110 Mm Outer Dia 560 50 Mm Outer Dia 561 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 562 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 563 Sub Head– Ii Water Supply 564 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 565 Internal Work – Exposed On Wall. 566 20 Mm Nominal Outer Dia Pipes 567 25 Mm Nominal Outer Dia Pipes 568 32 Mm Nominal Outer Dia Pipes 569 40 Mm Nominal Outer Dia Pipes 570 50 Mm Nominal Outer Dia Pipes 571 65 Mm Nominal Outer Dia Pipes 572 80 Mm Nominal Outer Dia Pipes 573 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 574 Concealed Including Cutting Chases And Making Good The Wall Etc. 575 15 Mm Nominal Outer Dia Pipes 576 20 Mm Nominal Outer Dia Pipes 577 25 Mm Nominal Outer Dia Pipes 578 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 579 20 Mm Dia. Nominal Bore 580 25 Mm Dia. Nominal Bore 581 32 Mm Dia. Nominal Bore 582 40 Mm Dia. Nominal Bore 583 50 Mm Dia. Nominal Bore 584 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 585 25 Mm Nominal Bore 586 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 587 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 588 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 589 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 590 15 Mm Nominal Bore 591 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 592 15 Mm Nominal Bore 593 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 594 15Mm Nominal Bore 595 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 596 45 Cm Length 597 15 Mm Nominal Bore 598 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 599 150 Mm Diameter 600 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 601 ( A ) 15 Mm Nominal Dia 602 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 603 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 604 Upto 50 Mm Dia. Nominal Bore 605 Subhead– Iii Drainage 606 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 607 150 Mm Diameter 608 200 Mm Diameter 609 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 610 180X150 Mm Size P Type 611 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 612 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 613 150 Mm Dia. R.C.C. Pipe 614 250 Mm Dia. R.C.C. Pipe 615 300 Mm Dia. R.C.C. Pipe 616 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 617 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 618 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 619 Extra Depth Formanhole 90X80 Cm 620 With Fpsbricks Class Designation 7.5 621 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 622 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 623 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 624 Electrical Works 0.375 Girls Dormitory With 3 Nos. Warden Residence 625 Sub Head - I: Circuit Cum Point Wiring 626 Switch Control Light Points 627 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 628 Group C 629 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 630 Group C 631 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 632 Group C 633 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 634 Group C 635 Mcb Control Light Points 636 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 637 Primary Point Controlled By One Mcb. 638 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 639 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 640 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 641 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 642 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 643 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 644 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 645 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 646 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 647 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 648 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 649 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 650 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 651 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 652 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 653 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 654 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 655 Telephone Socket Outlet 656 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 657 1 Or 2 Module ( 75Mmx75mm ) 658 6 Module ( 78Mm X 205 Mm X 50 Mm ) 659 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 660 3 Pin , 5 / 6 Amps Socket Outlet 661 5 / 6 Amps Switch 662 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 663 25 Mm 664 32 Mm 665 Subhead -Ii - Fittings & Fixtures 666 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 667 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 668 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 669 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 670 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 671 Supply, Installation, Testing And Commissioning Of150 W Chandelier 672 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 673 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 674 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 675 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 676 Subhead - Iii - Distribution Boards 677 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 678 6 Way, Double Door 679 8 Way, Double Door 680 12 Way, Double Door 681 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 682 4 Way ( 4 + 12 ) , Double Door 683 6 Way ( 4 + 18 ) , Double Door 684 8 Way ( 4 + 24 ) , Double Door 685 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 686 12 Way ( 4 + 36 ) , Double Door 687 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 688 Single Pole 689 Single Pole Neutral 690 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 691 40 A 692 63 A 693 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 694 25 A 695 40 A 696 63 A 697 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 698 25 A 699 40 A 700 63 A 701 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 702 Sub Head-Iv , Lightning Conductor 703 Lightning Conductor 704 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 705 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 706 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 707 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 708 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 709 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 710 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 711 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 712 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 713 [ Vice Principalresidence ] ( Type-4 ) 714 Earth Work 715 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil Anddisposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 716 All Kinds Of Soil 717 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 718 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 719 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 720 Concrete Work 721 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 722 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 723 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 724 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 725 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 726 Reinforced Cement Concrete 727 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 728 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 729 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 730 Lintels, Beams, Plinth Beams, Girders, Bressumers 731 Columns, Pillars, Piers, Abutments, Posts And Struts. 732 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 733 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 734 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 735 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 736 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 737 All Works Upto Plinth Level 738 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 739 ( I ) R.C.C. Work In Footing 740 ( Ii ) R.C.C. Work In Beam 741 ( Iii ) R.C.C. Work In Columns 742 All Works Above Plinth Level Upto Floor V Level 743 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 744 ( I ) R.C.C. Work In Lintel 745 ( Ii ) R.C.C. Work In Beam 746 ( Iii ) R.C.C. Work In Columns 747 ( Iv ) R.C.C. Work In Slab 748 Masonry Work 749 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 750 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 751 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : 752 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 753 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 754 Cladding Work 755 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 756 Area Of Slab Upto 0.50 Sqm 757 Area Of Slab Over 0.50 Sqm 758 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 759 Granite Work 760 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 761 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 762 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 763 Wood And Pvc Work 764 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 765 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 766 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 767 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 768 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 769 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Finecellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Selftapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As PermanufacturerS Specification And Direction Of Engineer-In-Charge. 770 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.0 Mm Thick 771 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size, Kiln Seasoned And Chemically Treated Hollock Wood 772 3000 Series Windows ( Double Rebate With Air Tight Glass Shutter Windows ) Providing& Fixing 3000 Series Windows Fabricated From Roll Formed Sections Made Of Galvanized Steel Colour Coated / Powder Coated ( Base Steel As Per Is 513 “D” Quality, Galvanized As Per Is 277 With Zinc Of 120 Grams / Sq. Mtr. ) With Total Coated Thickness Of 0.60 Mm.Paint Specifications:Coated Sections Should Be With Primer Coat Of Epoxy Primer Of 5-7 Microns Thick, Finish Painted With Polyester Paint Of 12-16 Microns Thick And Back Coated With Alkyd Backer Of 5-7 Microns, Or Powder Coated With Pure Polyester Powder Up To 50-60 Microns Thick. 773 Dimensions Of Sections:Section For Frame Should Be Of 98Mm X 50Mm, Section For Mullion Should Be Of 46Mm X 70Mm, Section For Shutter Frame Should Be Of 46Mm X 46 Mm, Section For Fixed Glass Bead Should Be Of 18Mm X 25Mm And Section For Fly Mesh Shutter Frame Should Be Of 20Mm X 40Mm.Fixing Details:Frame And Mesh Shutter Sections Should Be Cut To Length And Mitre Joined With Corner Bracket Made Of Polypropylene. Glass Shutter Should Be Mitre Joined With Corner Brackets Made Of Crca Electroplated. Mullion Section Should Be Joined With Frame / Mullion Using Nylon Mullion Cap Ethyl Propylene Diamine Monomer ( Epdm ) Gasket Should Be Used All Around Glass In Shutter Between Frame And Glazed Shutter And Both Sides Of Fixed Glass. Spoon Profile Should Be Used Around Fly Mesh To Fix Mesh In Mesh Shutter. 774 Accessories:Each Glazed Shutter Should Be Provided With Ms Powder Coated Friction Hinges – 1 Set, High Grade Aluminum Powder Coated Handle -1 No. Each Mesh Shutter Should Be Provided With S.S.Pivot Hinges-1 Set, Elixir Make Handle Shall Be Provided Per Shutter.Window Frame Should Be Fixed To Brick / Concrete Masonary By Using Nylon Self Expanding Caps And Driving Ms Electroplated 80Mm Long Screws Into The Caps Through Frames.Glass: Glass Shutter & Fixed Glass Portions Should Be Provided With A Glass Of 4Mm Plain Float Glass.Meshmesh Shutter Should Be Provided With A Stainless Steel 32 Gauge Fly Mesh Of 304 Grades With 144 Holes Per Square Inch.Grill:-Windows Should Be Provided With Grill Made Of 10Mm Sq. Ms Bars Welded To At 150Mm Center-To-Center, 6Mm X 12Mm Ms Flat. Total Grill Unit Should Be Powder Coated And Fixed To Window Frame With Screws. ( Make: A2z Infra Solutions / Elixir Metform Pvt Ltd. / Lakshmi Fabrications ) 775 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 776 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 777 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 778 300 X 10Mm 779 150 X 10Mm 780 Steel Work 781 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 782 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With :4.0 Mm Thick Glass Panes ( Weights Not Less Than 10 Kg / Sqm ) 783 Flooring 784 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 785 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 786 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laidon 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. Thetiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet Forplacing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Ofsize Of Tile 600 X 600 Mm 787 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm. 788 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 789 Finishing 790 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 791 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 792 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 793 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 794 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 795 Applying Priming Coat: 796 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 797 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 798 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 799 Two Or More Coats On New Work. 800 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 801 Water Proofing 802 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 803 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tiles Of Class Designation 10 804 Plumbing Internal Estimate ( Type-4 / Vice Principal Residence ) 805 Sub Head– I Sanitary Installation 806 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 807 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 808 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 809 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 810 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 811 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 812 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 813 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 814 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 815 Providing And Fixing Toilet Paper Holder : 816 C.P. Brass 817 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 818 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 819 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 820 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 821 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 822 Kitchen Sink With Drain Board 823 510X1040 Mm Bowl Depth 250Mm 824 Kitchen Sink Without Drain Board 825 610X460 Mm Bowl Depth 200 Mm 826 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 827 Size 450X300x150 Mm 828 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 829 Flexible Pipe 830 40 Mm Dia 831 Providing And Fixing Soil, Waste And Vent Pipes : 832 100 Mm Dia 833 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 834 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 835 100 Mm 836 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 837 Providing And Fixing Plain Bend Of Required Degree. 838 100 Mm 839 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 840 Providing And Fixing Heel Rest Sanitary Bend 841 100 Mm Dia 842 Sand Cast Iron S&S As Per Is - 3989 843 Providing And Fixing Double Equal Plain Junction Of Required Degree 844 100X100x100x100 Mm 845 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 846 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 847 100X100x100 Mm 848 Sand Cast Iron S&S As Per Is: 3989 849 Providing And Fixing Single Equal Plain Junction Of Required Degree 850 100X100x100 Mm 851 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 852 Providing And Fixing Terminal Guard: 853 100 Mm 854 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 855 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 856 100 Mm 857 S S 304 Grade Coupling With Epdm Rubber Gasket 858 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 859 100 Mm 860 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 861 100 Mm Diameter Pipe 862 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 863 100 Mm Diameter Pipe 864 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 865 32 Mm Dia. Nominal Bore 866 40 Mm Dia. Nominal Bore 867 50 Mm Dia. Nominal Bore 868 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 869 100 Mm Inlet And 100 Mm Outlet 870 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 871 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 872 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 873 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 874 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 875 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 876 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 877 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 878 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 879 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 880 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 881 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 882 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 883 Coupler 884 110 Mm 885 Single Tee With Door 886 110X110x110 Mm 887 Bend 87.5° 888 110 Mm 889 Shoe ( Plain ) 890 110 Mm Shoe 891 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 892 110 Mm 893 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 894 110 Mm Outer Dia 895 50 Mm Outer Dia 896 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 897 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 898 Sub Head– Ii Water Supply 899 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 900 Internal Work – Exposed On Wall. 901 20 Mm Nominal Outer Dia Pipes 902 25 Mm Nominal Outer Dia Pipes 903 32 Mm Nominal Outer Dia Pipes 904 40 Mm Nominal Outer Dia Pipes 905 50 Mm Nominal Outer Dia Pipes 906 65 Mm Nominal Outer Dia Pipes 907 80 Mm Nominal Outer Dia Pipes 908 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 909 Concealed Including Cutting Chases And Making Good The Wall Etc. 910 15 Mm Nominal Outer Dia Pipes 911 20 Mm Nominal Outer Dia Pipes 912 25 Mm Nominal Outer Dia Pipes 913 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 914 20 Mm Dia. Nominal Bore 915 25 Mm Dia. Nominal Bore 916 32 Mm Dia. Nominal Bore 917 40 Mm Dia. Nominal Bore 918 50 Mm Dia. Nominal Bore 919 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 920 25 Mm Nominal Bore 921 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 922 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 923 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 924 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 925 15 Mm Nominal Bore 926 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 927 15 Mm Nominal Bore 928 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 929 15Mm Nominal Bore 930 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 931 45 Cm Length 932 15 Mm Nominal Bore 933 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 934 150 Mm Diameter 935 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 936 ( A ) 15 Mm Nominal Dia 937 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 938 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 939 Upto 50 Mm Dia. Nominal Bore 940 Subhead– Iii Drainage 941 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 942 150 Mm Diameter 943 200 Mm Diameter 944 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 945 180X150 Mm Size P Type 946 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 947 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 948 150 Mm Dia. R.C.C. Pipe 949 250 Mm Dia. R.C.C. Pipe 950 300 Mm Dia. R.C.C. Pipe 951 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 952 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 953 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 954 Extra Depth Formanhole 90X80 Cm 955 With Fpsbricks Class Designation 7.5 956 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 957 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 958 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 959 Electrical Works Type - 4 Residence ( Vice Principal Residence ) 960 Sub Head - I: Circuit Cum Point Wiring 961 Switch Control Light Points 962 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 963 Group C 964 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 965 Group C 966 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 967 Group C 968 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 969 Group C 970 Mcb Control Light Points 971 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 972 Primary Point Controlled By One Mcb. 973 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 974 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 975 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 976 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 977 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 978 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 979 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 980 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 981 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 982 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 983 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 984 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 985 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 986 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 987 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 988 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 989 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 990 Telephone Socket Outlet 991 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 992 1 Or 2 Module ( 75Mmx75mm ) 993 6 Module ( 78Mm X 205 Mm X 50 Mm ) 994 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 995 3 Pin , 5 / 6 Amps Socket Outlet 996 5 / 6 Amps Switch 997 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 998 25 Mm 999 32 Mm 1000 Subhead -Ii - Fittings & Fixtures 1001 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1002 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1003 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1004 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1005 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1006 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1007 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1008 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1009 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1010 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1011 Subhead - Iii - Distribution Boards 1012 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1013 6 Way, Double Door 1014 8 Way, Double Door 1015 12 Way, Double Door 1016 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1017 4 Way ( 4 + 12 ) , Double Door 1018 6 Way ( 4 + 18 ) , Double Door 1019 8 Way ( 4 + 24 ) , Double Door 1020 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1021 12 Way ( 4 + 36 ) , Double Door 1022 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1023 Single Pole 1024 Single Pole Neutral 1025 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1026 40 A 1027 63 A 1028 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1029 25 A 1030 40 A 1031 63 A 1032 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1033 25 A 1034 40 A 1035 63 A 1036 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1037 Sub Head-Iv , Lightning Conductor 1038 Lightning Conductor 1039 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1040 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 1041 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1042 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1043 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1044 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1045 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1046 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 1047 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 1048 [ Type-Iii Residences G+2, 6Units. ] 1049 Earth Work 1050 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil Anddisposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 1051 All Kinds Of Soil 1052 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 1053 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming , Consolidating And Dressing Complete. 1054 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1055 Concrete Work 1056 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Sizederived From Natural Sources ) 1057 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 1058 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 1059 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over75mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 1060 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 1061 Reinforced Cement Concrete 1062 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights 1063 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1064 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 1065 Lintels, Beams, Plinth Beams, Girders, Bressumers 1066 Columns, Pillars, Piers, Abutments, Posts And Struts. 1067 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 1068 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1069 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 1070 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 1071 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of Theminimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 1072 All Works Upto Plinth Level 1073 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1074 ( I ) R.C.C. Work In Footing 1075 ( Ii ) R.C.C. Work In Beam 1076 ( Iii ) R.C.C. Work In Columns 1077 All Works Above Plinth Level Upto Floor V Level 1078 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 1079 ( I ) R.C.C. Work In Lintel 1080 ( Ii ) R.C.C. Work In Beam 1081 ( Iii ) R.C.C. Work In Columns 1082 ( Iv ) R.C.C. Work In Slab 1083 Masonry Work 1084 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 1085 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 1086 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1087 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1088 Cladding Work 1089 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 1090 Granite Stone Slab Colour Black, Cherry / Ruby Red 1091 Area Of Slab Upto 0.50 Sqm 1092 Area Of Slab Over 0.50 Sqm 1093 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 1094 Granite Work 1095 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 1096 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 1097 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1098 Wood And Pvc Work 1099 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is :2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Plyveneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Markedstainless Steel Butt Hinges With Necessary Screws 1100 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 1101 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 1102 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 1103 300 Mm Weighing Not Less Than 200 Gms 1104 250 Mm Weighing Not Less Than 150 Gms 1105 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 1106 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Finecellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Selftapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As PermanufacturerS Specification And Direction Of Engineer-In-Charge. 1107 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.5 Mm Thick 1108 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size 1109 Kiln Seasoned And Chemically Treated Hollock Wood 1110 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 1111 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 1112 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 1113 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 1114 300 X 10Mm 1115 150 X 10Mm 1116 Steel Work 1117 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 1118 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 1119 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 1120 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1121 M.S Raling 1122 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1123 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 1124 Flooring 1125 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 1126 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 1127 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600 X 600 Mm 1128 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 1129 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 1130 Finishing 1131 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 1132 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 1133 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 1134 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 1135 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 1136 Steel Painting:Applying Priming Coat 1137 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 1138 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 1139 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 1140 Two Or More Coats On New Work. 1141 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1142 Water Proofing 1143 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 1144 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 1145 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tiles Of Class Designation 10 1146 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 1147 Plumbing Internal Estimate ( Type-3 , 6 Unit ) ( G+2 ) 1148 Sub Head– I Sanitary Installation 1149 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 1150 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 1151 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 1152 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 1153 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 1154 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 1155 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 1156 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 1157 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 1158 Providing And Fixing Toilet Paper Holder : 1159 C.P. Brass 1160 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 1161 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 1162 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 1163 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 1164 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 1165 Kitchen Sink With Drain Board 1166 510X1040 Mm Bowl Depth 250Mm 1167 Kitchen Sink Without Drain Board 1168 610X460 Mm Bowl Depth 200 Mm 1169 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 1170 Size 450X300x150 Mm 1171 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 1172 Flexible Pipe 1173 40 Mm Dia 1174 Providing And Fixing Soil, Waste And Vent Pipes : 1175 100 Mm Dia 1176 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 1177 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1178 100 Mm 1179 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 1180 Providing And Fixing Plain Bend Of Required Degree. 1181 100 Mm 1182 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1183 Providing And Fixing Heel Rest Sanitary Bend 1184 100 Mm Dia 1185 Sand Cast Iron S&S As Per Is - 3989 1186 Providing And Fixing Double Equal Plain Junction Of Required Degree 1187 100X100x100x100 Mm 1188 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1189 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1190 100X100x100 Mm 1191 Sand Cast Iron S&S As Per Is: 3989 1192 Providing And Fixing Single Equal Plain Junction Of Required Degree 1193 100X100x100 Mm 1194 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1195 Providing And Fixing Terminal Guard: 1196 100 Mm 1197 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1198 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 1199 100 Mm 1200 S S 304 Grade Coupling With Epdm Rubber Gasket 1201 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 1202 100 Mm 1203 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 1204 100 Mm Diameter Pipe 1205 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 1206 100 Mm Diameter Pipe 1207 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1208 32 Mm Dia. Nominal Bore 1209 40 Mm Dia. Nominal Bore 1210 50 Mm Dia. Nominal Bore 1211 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 1212 100 Mm Inlet And 100 Mm Outlet 1213 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 1214 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 1215 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 1216 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 1217 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 1218 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 1219 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 1220 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 1221 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 1222 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 1223 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 1224 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 1225 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 1226 Coupler 1227 110 Mm 1228 Single Tee With Door 1229 110X110x110 Mm 1230 Bend 87.5° 1231 110 Mm 1232 Shoe ( Plain ) 1233 110 Mm Shoe 1234 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 1235 110 Mm 1236 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 1237 110 Mm Outer Dia 1238 50 Mm Outer Dia 1239 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 1240 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 1241 Sub Head– Ii Water Supply 1242 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1243 Internal Work – Exposed On Wall. 1244 20 Mm Nominal Outer Dia Pipes 1245 25 Mm Nominal Outer Dia Pipes 1246 32 Mm Nominal Outer Dia Pipes 1247 40 Mm Nominal Outer Dia Pipes 1248 50 Mm Nominal Outer Dia Pipes 1249 65 Mm Nominal Outer Dia Pipes 1250 80 Mm Nominal Outer Dia Pipes 1251 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 1252 Concealed Including Cutting Chases And Making Good The Wall Etc. 1253 15 Mm Nominal Outer Dia Pipes 1254 20 Mm Nominal Outer Dia Pipes 1255 25 Mm Nominal Outer Dia Pipes 1256 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1257 20 Mm Dia. Nominal Bore 1258 25 Mm Dia. Nominal Bore 1259 32 Mm Dia. Nominal Bore 1260 40 Mm Dia. Nominal Bore 1261 50 Mm Dia. Nominal Bore 1262 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 1263 25 Mm Nominal Bore 1264 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 1265 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 1266 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 1267 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 1268 15 Mm Nominal Bore 1269 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 1270 15 Mm Nominal Bore 1271 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 1272 15Mm Nominal Bore 1273 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 1274 45 Cm Length 1275 15 Mm Nominal Bore 1276 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 1277 150 Mm Diameter 1278 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 1279 ( A ) 15 Mm Nominal Dia 1280 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 1281 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 1282 Upto 50 Mm Dia. Nominal Bore 1283 Subhead– Iii Drainage 1284 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 1285 150 Mm Diameter 1286 200 Mm Diameter 1287 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 1288 180X150 Mm Size P Type 1289 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 1290 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1291 150 Mm Dia. R.C.C. Pipe 1292 250 Mm Dia. R.C.C. Pipe 1293 300 Mm Dia. R.C.C. Pipe 1294 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 1295 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 1296 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 1297 Extra Depth Formanhole 90X80 Cm 1298 With Fpsbricks Class Designation 7.5 1299 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 1300 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 1301 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1302 Electrical Works Type-3 ( G+2 ) Residence 1303 Sub Head - I: Circuit Cum Point Wiring 1304 Switch Control Light Points 1305 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1306 Group C 1307 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1308 Group C 1309 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1310 Group C 1311 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1312 Group C 1313 Mcb Control Light Points 1314 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1315 Primary Point Controlled By One Mcb. 1316 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1317 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1318 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1319 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1320 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1321 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1322 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1323 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1324 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1325 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1326 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1327 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1328 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1329 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1330 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1331 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1332 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1333 Telephone Socket Outlet 1334 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1335 1 Or 2 Module ( 75Mmx75mm ) 1336 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1337 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1338 3 Pin , 5 / 6 Amps Socket Outlet 1339 5 / 6 Amps Switch 1340 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1341 25 Mm 1342 32 Mm 1343 Subhead -Ii - Fittings & Fixtures 1344 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1345 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1346 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1347 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1348 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1349 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1350 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1351 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1352 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1353 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1354 Subhead - Iii - Distribution Boards 1355 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1356 6 Way, Double Door 1357 8 Way, Double Door 1358 12 Way, Double Door 1359 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1360 4 Way ( 4 + 12 ) , Double Door 1361 6 Way ( 4 + 18 ) , Double Door 1362 8 Way ( 4 + 24 ) , Double Door 1363 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1364 12 Way ( 4 + 36 ) , Double Door 1365 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1366 Single Pole 1367 Single Pole Neutral 1368 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1369 40 A 1370 63 A 1371 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1372 25 A 1373 40 A 1374 63 A 1375 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1376 25 A 1377 40 A 1378 63 A 1379 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1380 Sub Head-Iv , Lightning Conductor 1381 Lightning Conductor 1382 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1383 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 1384 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1385 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1386 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1387 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1388 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1389 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 1390 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 1391 [ Type-Ii Residences ( G+3 ) , 7 Units. ] 1392 Earth Work 1393 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 1394 All Kinds Of Soil 1395 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 1396 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming , Consolidating And Dressing Complete. 1397 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1398 Concrete Work 1399 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1400 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 1401 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 1402 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over75mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 1403 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 1404 Reinforced Cement Concrete 1405 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights 1406 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1407 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 1408 Lintels, Beams, Plinth Beams, Girders, Bressumers 1409 Columns, Pillars, Piers, Abutments, Posts And Struts. 1410 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 1411 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1412 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 1413 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 1414 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of Theminimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 1415 All Works Upto Plinth Level 1416 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1417 ( I ) R.C.C. Work In Footing 1418 ( Ii ) R.C.C. Work In Beam 1419 ( Iii ) R.C.C. Work In Columns 1420 All Works Above Plinth Level Upto Floor V Level 1421 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 1422 ( I ) R.C.C. Work In Lintel 1423 ( Ii ) R.C.C. Work In Beam 1424 ( Iii ) R.C.C. Work In Columns 1425 ( Iv ) R.C.C. Work In Slab 1426 Masonry Work 1427 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 1428 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 1429 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1430 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1431 Cladding Work 1432 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 1433 Granite Stone Slab Colour Black, Cherry / Ruby Red 1434 Area Of Slab Upto 0.50 Sqm 1435 Area Of Slab Over 0.50 Sqm 1436 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 1437 Granite Work 1438 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 1439 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 1440 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1441 Wood And Pvc Work 1442 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is :2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Plyveneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Markedstainless Steel Butt Hinges With Necessary Screws 1443 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 1444 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 1445 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 1446 300 Mm Weighing Not Less Than 200 Gms 1447 250 Mm Weighing Not Less Than 150 Gms 1448 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 1449 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 1450 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.5 Mm Thick 1451 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size 1452 Kiln Seasoned And Chemically Treated Hollock Wood 1453 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 1454 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 1455 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 1456 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 1457 200 X 10Mm 1458 150 X 10Mm 1459 Steel Work 1460 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 1461 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 1462 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 1463 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1464 Ms Railing 1465 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1466 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 1467 Flooring 1468 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 1469 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 1470 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Requiredthickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600 X 600 Mm 1471 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 1472 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 1473 Finishing 1474 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 1475 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 1476 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 1477 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 1478 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 1479 Steel Painting:Applying Priming Coat 1480 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 1481 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 1482 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 1483 Two Or More Coats On New Work. 1484 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1485 Water Proofing 1486 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 1487 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 1488 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tilesof Class Designation 10 1489 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 1490 Plumbing Internal Estimate ( Type-2 , 7 Unit ) ( G+3 ) 1491 Sub Head– I Sanitary Installation 1492 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 1493 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 1494 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 1495 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 1496 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 1497 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 1498 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 1499 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 1500 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 1501 Providing And Fixing Toilet Paper Holder : 1502 C.P. Brass 1503 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 1504 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 1505 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 1506 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 1507 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 1508 Kitchen Sink With Drain Board 1509 510X1040 Mm Bowl Depth 250Mm 1510 Kitchen Sink Without Drain Board 1511 610X460 Mm Bowl Depth 200 Mm 1512 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 1513 Size 450X300x150 Mm 1514 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 1515 Flexible Pipe 1516 40 Mm Dia 1517 Providing And Fixing Soil, Waste And Vent Pipes : 1518 100 Mm Dia 1519 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 1520 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1521 100 Mm 1522 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 1523 Providing And Fixing Plain Bend Of Required Degree. 1524 100 Mm 1525 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1526 Providing And Fixing Heel Rest Sanitary Bend 1527 100 Mm Dia 1528 Sand Cast Iron S&S As Per Is - 3989 1529 Providing And Fixing Double Equal Plain Junction Of Required Degree 1530 100X100x100x100 Mm 1531 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1532 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1533 100X100x100 Mm 1534 Sand Cast Iron S&S As Per Is: 3989 1535 Providing And Fixing Single Equal Plain Junction Of Required Degree 1536 100X100x100 Mm 1537 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1538 Providing And Fixing Terminal Guard: 1539 100 Mm 1540 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1541 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 1542 100 Mm 1543 S S 304 Grade Coupling With Epdm Rubber Gasket 1544 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 1545 100 Mm 1546 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 1547 100 Mm Diameter Pipe 1548 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 1549 100 Mm Diameter Pipe 1550 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1551 32 Mm Dia. Nominal Bore 1552 40 Mm Dia. Nominal Bore 1553 50 Mm Dia. Nominal Bore 1554 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 1555 100 Mm Inlet And 100 Mm Outlet 1556 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 1557 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 1558 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 1559 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 1560 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 1561 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 1562 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 1563 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 1564 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 1565 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 1566 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 1567 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 1568 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 1569 Coupler 1570 110 Mm 1571 Single Tee With Door 1572 110X110x110 Mm 1573 Bend 87.5° 1574 110 Mm 1575 Shoe ( Plain ) 1576 110 Mm Shoe 1577 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 1578 110 Mm 1579 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 1580 110 Mm Outer Dia 1581 50 Mm Outer Dia 1582 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 1583 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 1584 Sub Head– Ii Water Supply 1585 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1586 Internal Work – Exposed On Wall. 1587 20 Mm Nominal Outer Dia Pipes 1588 25 Mm Nominal Outer Dia Pipes 1589 32 Mm Nominal Outer Dia Pipes 1590 40 Mm Nominal Outer Dia Pipes 1591 50 Mm Nominal Outer Dia Pipes 1592 65 Mm Nominal Outer Dia Pipes 1593 80 Mm Nominal Outer Dia Pipes 1594 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 1595 Concealed Including Cutting Chases And Making Good The Wall Etc. 1596 15 Mm Nominal Outer Dia Pipes 1597 20 Mm Nominal Outer Dia Pipes 1598 25 Mm Nominal Outer Dia Pipes 1599 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1600 20 Mm Dia. Nominal Bore 1601 25 Mm Dia. Nominal Bore 1602 32 Mm Dia. Nominal Bore 1603 40 Mm Dia. Nominal Bore 1604 50 Mm Dia. Nominal Bore 1605 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 1606 25 Mm Nominal Bore 1607 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 1608 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 1609 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 1610 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 1611 15 Mm Nominal Bore 1612 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 1613 15 Mm Nominal Bore 1614 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 1615 15Mm Nominal Bore 1616 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 1617 45 Cm Length 1618 15 Mm Nominal Bore 1619 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 1620 150 Mm Diameter 1621 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 1622 ( A ) 15 Mm Nominal Dia 1623 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 1624 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 1625 Upto 50 Mm Dia. Nominal Bore 1626 Subhead– Iii Drainage 1627 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 1628 150 Mm Diameter 1629 200 Mm Diameter 1630 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 1631 180X150 Mm Size P Type 1632 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 1633 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1634 150 Mm Dia. R.C.C. Pipe 1635 250 Mm Dia. R.C.C. Pipe 1636 300 Mm Dia. R.C.C. Pipe 1637 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 1638 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 1639 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 1640 Extra Depth Formanhole 90X80 Cm 1641 With Fpsbricks Class Designation 7.5 1642 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 1643 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 1644 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1645 Electrical Works Type-2 ( G+3 ) Residence 1646 Sub Head - I: Circuit Cum Point Wiring 1647 Switch Control Light Points 1648 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1649 Group C 1650 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1651 Group C 1652 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1653 Group C 1654 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1655 Group C 1656 Mcb Control Light Points 1657 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1658 Primary Point Controlled By One Mcb. 1659 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1660 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1661 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1662 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1663 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1664 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1665 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1666 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1667 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1668 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1669 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1670 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1671 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1672 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1673 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1674 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1675 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1676 Telephone Socket Outlet 1677 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1678 1 Or 2 Module ( 75Mmx75mm ) 1679 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1680 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1681 3 Pin , 5 / 6 Amps Socket Outlet 1682 5 / 6 Amps Switch 1683 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1684 25 Mm 1685 32 Mm 1686 Subhead -Ii - Fittings & Fixtures 1687 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1688 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1689 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1690 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1691 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1692 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1693 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1694 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1695 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1696 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1697 Subhead - Iii - Distribution Boards 1698 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1699 6 Way, Double Door 1700 8 Way, Double Door 1701 12 Way, Double Door 1702 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1703 4 Way ( 4 + 12 ) , Double Door 1704 6 Way ( 4 + 18 ) , Double Door 1705 8 Way ( 4 + 24 ) , Double Door 1706 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1707 12 Way ( 4 + 36 ) , Double Door 1708 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1709 Single Pole 1710 Single Pole Neutral 1711 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1712 40 A 1713 63 A 1714 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1715 25 A 1716 40 A 1717 63 A 1718 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1719 25 A 1720 40 A 1721 63 A 1722 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1723 Sub Head-Iv , Lightning Conductor 1724 Lightning Conductor 1725 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1726 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 1727 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1728 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1729 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1730 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1731 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1732 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 1733 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 1734 [ Guest House ] 1735 Earth Work 1736 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil Anddisposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 1737 All Kinds Of Soil 1738 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 1739 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 1740 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1741 Concrete Work 1742 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1743 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 1744 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 1745 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed Andconsolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 1746 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 1747 Reinforced Cement Concrete 1748 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 1749 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1750 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 1751 Lintels, Beams, Plinth Beams, Girders, Bressumers 1752 Columns, Pillars, Piers, Abutments, Posts And Struts. 1753 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 1754 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1755 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 1756 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 1757 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarseaggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures Inrecommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairingstrength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 1758 All Works Upto Plinth Level 1759 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1760 ( I ) R.C.C. Work In Footing 1761 ( Ii ) R.C.C. Work In Beam 1762 ( Iii ) R.C.C. Work In Columns 1763 All Works Above Plinth Level Upto Floor V Level 1764 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1765 ( I ) R.C.C. Work In Lintel 1766 ( Ii ) R.C.C. Work In Beam 1767 ( Iii ) R.C.C. Work In Columns 1768 ( Iv ) R.C.C. Work In Slab 1769 Masonry Work 1770 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 1771 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 1772 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : 1773 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1774 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1775 Cladding Work 1776 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness Tobe Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Stepsand Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointin With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1777 Wood And Pvc Work 1778 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Bothfaces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 1779 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 1780 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 1781 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 1782 300 Mm Weighing Not Less Than 200 Gms 1783 250 Mm Weighing Not Less Than 150 Gms 1784 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 1785 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Finecellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Selftapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As PermanufacturerS Specification And Direction Of Engineer-In-Charge. 1786 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.0 Mm Thick 1787 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size, Kiln Seasoned And Chemically Treated Hollock Wood 1788 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 1789 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 1790 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 1791 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 1792 300 X 10Mm 1793 150 X 10Mm 1794 Steel Work 1795 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 1796 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 1797 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 1798 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 1799 Flooring 1800 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 1801 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 1802 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laidon 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. Thetiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet Forplacing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Ofsize Of Tile 600 X 600 Mm 1803 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm. 1804 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 1805 Finishing 1806 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 1807 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 1808 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 1809 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 1810 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 1811 Applying Priming Coat: 1812 With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood 1813 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 1814 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 1815 Two Or More Coats On New Work. 1816 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1817 Water Proofing 1818 Providing And Laying In Situ Seven Course Water Proofing Treatment With App ( Atactic Poly-Propylene ) Modified Polymeric Memberane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40 Litre Per Sqm, 2Nd, 4Th & 6Th Courses Of Bonding Material @ 1.20 Kg / Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85 / 25 Conforming To Is : 702, 3Rd And 5Th Layers Of Roofing Membrane App Modified Polymeric Membrane 1.5 Mm Thick Of 2.25 Kg / Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 20 Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20 Micron Hmhdpe Film. 7Th, The Top Most Layer Shall Be Finished With Brick Tiles Of Class Designation 10 Grouted With Cement Mortar 1:3 ( 1Cement : 3 Fine Sand ) Mixed With 2% Integral Water Proofing Compound By Weight Of Cement Over A 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat ( Item Of Laying Brick Tiles Shall Be Paid For Separately ) . 1819 Providing And Laying Brick Tiles Over Mumty Roofs, Grouted With Cementmortar 1:3 ( 1 Cement : 3 Fine Sand ) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement, Over 12 Mm Layer Of Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) And Finished Neat:With Common Burnt Clay F.P.S. ( Non Modular ) Brick Tiles Of Class Designation 10 1820 Plumbing Internal Estimate ( Guest House ) 1821 Sub Head– I Sanitary Installation 1822 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 1823 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 1824 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 1825 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 1826 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 1827 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 1828 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 1829 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 1830 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 1831 Providing And Fixing Toilet Paper Holder : 1832 C.P. Brass 1833 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 1834 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 1835 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 1836 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 1837 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 1838 Kitchen Sink With Drain Board 1839 510X1040 Mm Bowl Depth 250Mm 1840 Kitchen Sink Without Drain Board 1841 610X460 Mm Bowl Depth 200 Mm 1842 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 1843 Size 450X300x150 Mm 1844 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 1845 Flexible Pipe 1846 40 Mm Dia 1847 Providing And Fixing Soil, Waste And Vent Pipes : 1848 100 Mm Dia 1849 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 1850 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1851 100 Mm 1852 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 1853 Providing And Fixing Plain Bend Of Required Degree. 1854 100 Mm 1855 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1856 Providing And Fixing Heel Rest Sanitary Bend 1857 100 Mm Dia 1858 Sand Cast Iron S&S As Per Is - 3989 1859 Providing And Fixing Double Equal Plain Junction Of Required Degree 1860 100X100x100x100 Mm 1861 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1862 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1863 100X100x100 Mm 1864 Sand Cast Iron S&S As Per Is: 3989 1865 Providing And Fixing Single Equal Plain Junction Of Required Degree 1866 100X100x100 Mm 1867 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1868 Providing And Fixing Terminal Guard: 1869 100 Mm 1870 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1871 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 1872 100 Mm 1873 S S 304 Grade Coupling With Epdm Rubber Gasket 1874 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 1875 100 Mm 1876 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 1877 100 Mm Diameter Pipe 1878 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 1879 100 Mm Diameter Pipe 1880 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1881 32 Mm Dia. Nominal Bore 1882 40 Mm Dia. Nominal Bore 1883 50 Mm Dia. Nominal Bore 1884 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 1885 100 Mm Inlet And 100 Mm Outlet 1886 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 1887 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 1888 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 1889 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 1890 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 1891 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 1892 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 1893 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 1894 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 1895 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 1896 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 1897 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 1898 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 1899 Coupler 1900 110 Mm 1901 Single Tee With Door 1902 110X110x110 Mm 1903 Bend 87.5° 1904 110 Mm 1905 Shoe ( Plain ) 1906 110 Mm Shoe 1907 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 1908 110 Mm 1909 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 1910 110 Mm Outer Dia 1911 50 Mm Outer Dia 1912 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 1913 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 1914 Sub Head– Ii Water Supply 1915 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1916 Internal Work – Exposed On Wall. 1917 20 Mm Nominal Outer Dia Pipes 1918 25 Mm Nominal Outer Dia Pipes 1919 32 Mm Nominal Outer Dia Pipes 1920 40 Mm Nominal Outer Dia Pipes 1921 50 Mm Nominal Outer Dia Pipes 1922 65 Mm Nominal Outer Dia Pipes 1923 80 Mm Nominal Outer Dia Pipes 1924 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 1925 Concealed Including Cutting Chases And Making Good The Wall Etc. 1926 15 Mm Nominal Outer Dia Pipes 1927 20 Mm Nominal Outer Dia Pipes 1928 25 Mm Nominal Outer Dia Pipes 1929 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1930 20 Mm Dia. Nominal Bore 1931 25 Mm Dia. Nominal Bore 1932 32 Mm Dia. Nominal Bore 1933 40 Mm Dia. Nominal Bore 1934 50 Mm Dia. Nominal Bore 1935 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 1936 25 Mm Nominal Bore 1937 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 1938 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 1939 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 1940 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 1941 15 Mm Nominal Bore 1942 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 1943 15 Mm Nominal Bore 1944 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 1945 15Mm Nominal Bore 1946 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 1947 45 Cm Length 1948 15 Mm Nominal Bore 1949 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 1950 150 Mm Diameter 1951 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 1952 ( A ) 15 Mm Nominal Dia 1953 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 1954 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 1955 Upto 50 Mm Dia. Nominal Bore 1956 Electrical Worksguest House 1957 Sub Head - I: Circuit Cum Point Wiring 1958 Switch Control Light Points 1959 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1960 Group C 1961 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1962 Group C 1963 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1964 Group C 1965 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1966 Group C 1967 Mcb Control Light Points 1968 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1969 Primary Point Controlled By One Mcb. 1970 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1971 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1972 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1973 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1974 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1975 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1976 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1977 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1978 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1979 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1980 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1981 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1982 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1983 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1984 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1985 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1986 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1987 Telephone Socket Outlet 1988 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1989 1 Or 2 Module ( 75Mmx75mm ) 1990 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1991 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1992 3 Pin , 5 / 6 Amps Socket Outlet 1993 5 / 6 Amps Switch 1994 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1995 25 Mm 1996 32 Mm 1997 Subhead -Ii - Fittings & Fixtures 1998 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1999 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 2000 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 2001 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 2002 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 2003 Supply, Installation, Testing And Commissioning Of150 W Chandelier 2004 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 2005 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 2006 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 2007 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 2008 Subhead - Iii - Distribution Boards 2009 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2010 6 Way, Double Door 2011 8 Way, Double Door 2012 12 Way, Double Door 2013 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2014 4 Way ( 4 + 12 ) , Double Door 2015 6 Way ( 4 + 18 ) , Double Door 2016 8 Way ( 4 + 24 ) , Double Door 2017 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 2018 12 Way ( 4 + 36 ) , Double Door 2019 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 2020 Single Pole 2021 Single Pole Neutral 2022 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 2023 40 A 2024 63 A 2025 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 2026 25 A 2027 40 A 2028 63 A 2029 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 2030 25 A 2031 40 A 2032 63 A 2033 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 2034 Sub Head-Iv , Lightning Conductor 2035 Lightning Conductor 2036 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 2037 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 2038 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 2039 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 2040 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 2041 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 2042 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 2043 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 2044 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 2045 Cutting & Filling 2046 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. 2047 Ordinary Rock 2048 Footpath 2.00 Mt. Wide 2049 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge 2050 All Kinds Of Soil 2051 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level. 2052 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 2053 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved S;Ze, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 2054 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Ncluding Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ) . ( Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge ) . 2055 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : 2056 Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture 2057 Supplying And Stacking At Site. 2058 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Ofoundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 2059 Deduct Pcc 2060 Kurb Stone 2061 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 2062 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 2063 Bituminus Road For 3.5 Mtr Wide & 10.0 Mtr Long Road 2064 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. 2065 All Kinds Of Soil 2066 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level. 2067 1:5:10 ( 1 Cement : 5 Course Bound: 10 Graded Stone Aggregate 40Mm Nominal Size ) 2068 Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Of Surplus Earthwith Lead Upto 50 Metres. 2069 Supplying And Stacking At Site.90 Mm To 45 Mm Size Stone Aggregate 2070 Supplying And Stacking At Site63 Mm To 45 Mm Size Stone Aggregate 2071 Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Pecifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road / Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Densi 2072 Sub Base With Stone Aggregate 90 Mm To 45 Mm Including Stone Screening 13.2 Mm Size. 2073 Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Pecifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road / Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Densi 2074 Base Course With 63 Mm To 45 Mm Size Including Stone Screening 13.2 Mm Size 2075 Supplying And Stacking At Sitestone Screening 13.2 Mm Nominal Size ( Type A ) 2076 Supplying And Stacking At Sitestone Screening 11.2 Mm Nominal Size ( Type B ) 2077 Supplying And Stacking At Sitered Bajri 2078 Supplying And Stacking At Sitemoorum 2079 2.5 Cm Premix Carpet Surfacing With 2.25 Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively, Including A Tack Coat With Hot Straight Run Bitumen, Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete ( Tack Coat To Be Paid For Separately ) .With Paving Asphalt Grade Vg - 10 Heated And Then Mixed With Solvent At The Rate Of 70 Grams Per Kg Of Asphalt 2080 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Ncluding Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ) . ( Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge ) . 2081 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : 2082 Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture 2083 Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications :On W.B.M. @ 0.75 Kg / Sqm 2084 Providing And Laying Seal Coat Of Premixed Fine Aggregate ( Passing 2.36 Mm And Retained On 180 Micron Sieve ) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg - 10 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface, Including Rolling And Finishing With Road Roller All Complete 2085 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 2086 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Havingthermal Stability For Hot & Cold Water Supply Including All Cpvc Plain &Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With Onestep Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Completeas Per Direction Of Engineer In Charge. 2087 External Work 2088 20 Mm Dia Nominal Bore 2089 25 Mm Dia Nominal Bore 2090 32 Mm Dia Nominal Bore 2091 40 Mm Dia Nominal Bore 2092 50 Mm Dia Nominal Bore 2093 65 Mm Dia Nominal Bore 2094 80 Mm Dia Nominal Bore 2095 Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) : 2096 50 Mm Dia 2097 80 Mm Dia 2098 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 2099 20 Mm Nominal Bore 2100 25 Mm Nominal Bore 2101 32 Mm Nominal Bore 2102 40 Mm Nominal Bore 2103 50 Mm Nominal Bore 2104 65 Mm Nominal Bore 2105 80 Mm Nominal Bore 2106 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 2107 Providing And Fixing G.I. Union In Gi Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 2108 25 Mm Nominal Bore 2109 32 Mm Nominal Bore 2110 40 Mm Nominal Bore 2111 50 Mm Nominal Bore 2112 65 Mm Nominal Bore 2113 80 Mm Nominal Bore 2114 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 2115 Ld- 2.5 2116 Rectangular Shape 600*450 Mm Internal Dimensions 2117 Constructing Masonry Gate Valve Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 2118 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 2119 Constructing Masonry Chamber 60X45x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Water Meter Complete With C.I. Double Flap Surface Box 400X200x200 Mm ( Inside ) With Locking Arrangement And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 2120 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 2121 Take 1.00 Mtr Length 2122 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2123 All Kinds Of Soil 2124 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 2125 Qty. = 25% Of Them No 1 2126 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shttering - All Work Up To Plinth Level 2127 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2128 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 2129 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 2130 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 2131 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 2132 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In : 2133 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 2134 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix : 2135 1:4 ( 1 Cement: 4 Fine Sand ) 2136 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : 2137 All Kinds Of Soil 2138 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm 2139 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 2140 450 Mm Dia. R.C.C. Pipe 2141 Providingandlayingcementconcrete 1 : 5 : 10 ( 1 Cement : 5 Coarse Sand : 10 Gradded Stoneaggregate40 Mm Nominal Size ) Alround S.W. Pipesincludingbed Concrete As Per Standard Design. 2142 450 Mm Diameter S.W.Pipe 2143 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. Anddisposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : 2144 All Kinds Of Soil 2145 Pipes, Cables Etc. Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia 2146 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 2147 150 Mm Dia. R.C.C. Pipe 2148 250 Mm Diameter S.W. Pipe 2149 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shttering - All Work Up To Plinth Level 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2150 150 Mm Diameter S.W.Pipe ( 282.46*0.35*0.10=9.89 ) 2151 250 Mm Diameter S.W. Pipe ( L*0.45*0.10=0.40 ) 2152 Constructing Brick Masonry Manholein Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) With Rcc Top Slab With 1 : 2 : 4 Mix ( 1 Cement : 2 Coarse Sand : 4Gradestone Aggregate 20Mm Nominal Size ) ; Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Gradedstoneaggregate40 Mm Nominalsize ) Insideplastering 12 Mm Thickwith Cementmortar 1:3 ( 1Cement 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement And Makingchannels Incementconcrete 1:2:4 ( 1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finishd With A Floating Coat Ofneatcement Completeasper Standard Design 2153 Inside Size 90 X 80 Cm & 45 Cmdeep Including Ci Cover With Frame ( Light Duty ) 455 X 610Mm Internal Dimensions, Total Weight Of Cover & Frame To Be Not Lessthan 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) 2154 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Classic Designation 7.5 2155 Extra For Depth For Manholes: 2156 Size 90 X 80 Cm 2157 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 2158 Constructing Brick Masonry Circular Type Manhole 0.91 M Internal Dia At Bottom And 0.56M Dia At Top With Fps Bricksclass Designation 75In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Inside Cement Plaster 12Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Of Neat Cement, Foundation Concrete 1:3:6 Mix ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 40Mm Nominal Size ) And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. 2159 0.91M Deep With Sfrc Cover And Frame ( Heavy Duty Hd-20 Grade Designation ) 560Mm Internal Diameter Conforming To I.S:12592, Total Weight Of Cover And Frame To Be Not Less Than 182Kg. Fixed In Cement Concrete 1:2:4 Mix ( 1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Centering, Shuttering All Complete. ( Excavation Foot Rests And 12Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately ) 2160 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 2161 Extra Depth For Circuler Type Manholes 0.91 M Internal Dia ( At Bottom ) Beyond 0.91M To 1.67 M . 2162 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 2163 Providing And Fixing Square Mouths. W. Gully Trapclass Sp-1 Complete With C.I. Gratingbrickmasonry Chamber With Water Tight Ci Cover With Frame Of 300 X 300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 2164 180 X 150 Mm. Size P Type 2165 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 2166 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20x10 Cm Cement Concrete Blocks 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) As Per Standard Design : 2167 With 20 Mm Dia Round Bar 2168 Size Of Tank = 5.70 X 2.10 X 1.70 Mtr Septic Tank ( 100 UserS ) 2169 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2170 All Kinds Soil 2171 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2172 Earth Work In Excavation 1.50-3.00 Mtr 2173 All Kinds Soil 2174 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 2175 20 % Of Excavation Of Items ( 1.A.1+2.A.1 ) 2176 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 2177 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2178 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.“ ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum.“Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . 2179 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 2180 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 2181 Pcc 2182 Raft 2183 Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 2184 Wall 2185 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 2186 Rcc Bend Beam 2187 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 2188 Slab 2189 Edges Of Slabs And Breaks In Floors And Walls. 2190 Under 20 Cm Wide 2191 Side 2192 Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. 2193 Thermo-Mechanically Treated Bars. 2194 Up To Plinth 2195 Qty Same As Item No 5 2196 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 2197 For Maintaining Slope 2198 6 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 2199 1:3 ( 1 Cement: 3 Fine Sand ) 2200 Outer Side 2201 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 2202 Hd-20 2203 Circular Shape 560 Mm Internal Diameter 2204 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910 On 12Mm Dia Steel Bar Conforming To Is : 1786 Having Minimum Cross Section As 23 Mmx25mm And Over All Minimum Length 263 Mm And Width As 165Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 2205 Providing And Fixing Soil, Waste And Vent Pipes 2206 100 Mm Dia. 2207 Centrifugally Cast ( Spun ) Iron Socketed Pipe As Per Is: 3989. 2208 Inlet + Outlet 2209 Vent Pipe 2210 Providing And Fixing Terminal Guard : 2211 100 Mm 2212 Sand Cast Iron S&S As Per Is - 3989 2213 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks Of Class Designation 75 And S.W. Drain Pipe 100 Mm Diameter, 1.8M Long Complete As Per Standard Design.With F.P.S. Bricks 2214 Size Of Tank = 5.00 X 2.00 X 1.24 Mtrseptic Tank ( 50 UserS ) 2215 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2216 All Kinds Soil 2217 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2218 Earth Work In Excavation 1.50-3.00 Mtr 2219 All Kinds Soil 2220 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 2221 20 % Of Excavation Of Items ( 1.A.1+2.A.1 ) 2222 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 2223 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2224 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.“ ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum.“Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . 2225 Upto Plinth Level 2226 Raft 2227 Slab 2228 Rcc Bend Beam 2229 Rccwall 2230 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 2231 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 2232 Pcc 2233 Raft 2234 Slab Beam 2235 Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 2236 Wall 2237 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 2238 Rcc Bend Beam 2239 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 2240 Slab 2241 Edges Of Slabs And Breaks In Floors And Walls. 2242 Under 20 Cm Wide 2243 Side 2244 Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. 2245 Thermo-Mechanically Treated Bars. 2246 Up To Plinth 2247 Qty Same As Item No 5 2248 1:3 ( 1 Cement: 3 Fine Sand ) 2249 For Maintaining Slope 2250 6 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 2251 1:3 ( 1 Cement: 3 Fine Sand ) 2252 Outer Side 2253 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 2254 Hd-20 2255 Circular Shape 560 Mm Internal Diameter 2256 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910 On 12Mm Dia Steel Bar Conforming To Is : 1786 Having Minimum Cross Section As 23 Mmx25mm And Over All Minimum Length 263 Mm And Width As 165Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 2257 Providing And Fixing Soil, Waste And Vent Pipes 2258 100 Mm Dia. 2259 Centrifugally Cast ( Spun ) Iron Socketed Pipe As Per Is: 3989. 2260 Inlet + Outlet 2261 Vent Pipe 2262 Providing And Fixing Terminal Guard : 2263 100 Mm 2264 Sand Cast Iron S&S As Per Is - 3989 2265 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks Of Class Designation 75 And S.W. Drain Pipe 100 Mm Diameter, 1.8M Long Complete As Per Standard Design.With F.P.S. Bricks 2266 Size Of Tank = 2.30 X 1.10 X 1.80 Mtrseptic Tank ( 20 UserS ) 2267 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2268 All Kinds Soil 2269 Take 100 % Qty Of Items 1.A 2270 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 2271 Earth Work In Excavation 1.50-3.00 Mtr 2272 All Kinds Soil 2273 Take 100 % Qty Of Items 2.A 2274 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 2275 20 % Of Excavation Of Items ( 1.A.1+2.A.1 ) 2276 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 2277 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2278 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.“ ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum.“Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . 2279 Upto Plinth Level 2280 Raft 2281 Slab 2282 Rccwall 2283 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 2284 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 2285 Pcc 2286 Raft 2287 Wall 2288 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 2289 Slab 2290 Edges Of Slabs And Breaks In Floors And Walls. 2291 Under 20 Cm Wide 2292 Side 2293 Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. 2294 Thermo-Mechanically Treated Bars. 2295 Up To Plinth 2296 Qty Same As Item No 5 2297 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 2298 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 2299 6 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 2300 1:3 ( 1 Cement: 3Fine Sand ) 2301 Outer Side 2302 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 2303 Hd-20 2304 Circular Shape 560 Mm Internal Diameter 2305 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910 On 12Mm Dia Steel Bar Conforming To Is : 1786 Having Minimum Cross Section As 23 Mmx25mm And Over All Minimum Length 263 Mm And Width As 165Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 2306 Providing And Fixing Soil, Waste And Vent Pipes 2307 100 Mm Dia. 2308 Centrifugally Cast ( Spun ) Iron Socketed Pipe As Per Is: 3989. 2309 Inlet + Outlet 2310 Vent Pipe 2311 Providing And Fixing Terminal Guard : 2312 100 Mm 2313 Sand Cast Iron S&S As Per Is - 3989 2314 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks Of Class Designation 75 And S.W. Drain Pipe 100 Mm Diameter, 1.8M Long Complete As Per Standard Design.With F.P.S. Bricks 2315 Stone Steps ( Staircase -1 ) 2316 Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) At Plinth Level With: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 2317 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 2318 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 2319 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . 2320 On Top 2321 Rr Masonary Retaining Wall ( 0.50 Mtr High ) 2322 Rr Masonary Retaining Wall ( 1.20 Mtr High ) 2323 Rr Masonary Retaining Wall ( 2.00 Mtr High ) 2324 Rr Masonary Retaining Wall ( 3.00 Mtr High ) 2325 2.0 Mtr Ht Rr Masonary Retainingwall 2326 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M.Upto 1.5M Depth 2327 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level 2328 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) 2329 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 2330 Qty 20% Item No -1 2331 Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) At Plinth Level With: 2332 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 2333 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 2334 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand Andmanufacture 2335 Providing And Fixing On Wall Face Plasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( 110 Mm Diameter ) 2336 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Finesand ) : 2337 Raised And Cut Pointing 2338 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 2339 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . 2340 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 2341 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 2342 Edges Of Slabs And Breaks In Floors And Walls 2343 Under 20 Cm Wide 2344 Subhead - I - Main Boards 2345 Design, Fabrication, Assembly, Wiring And Supply Of Front Operated Dead Front Cubicle Type Compartmentalised As Per Form 3B, Rear Access Free Standing, Dust And Vermin Proof ( Ip 42 Ingress Protection ) Main Switchboards Suitable For Use At 415 Volts, 3 Phase 4 Wire 50 Hertz System Suitable For A Symmetrical Fault Level Of 50 Ka At 415 Volts, Fabricated From 2 Mm Thick Crca Ms Sheets With Hinged, Gasketted ( Metal Based Neoprene ) And Lockable Doors Having Structural Reinforcement With Suitable Angle / Channel / T / Flat Sections Including 3 Mm Thick Gland Plates On Top And Bottom And Including Lifting Hooks And Including Gi Earth Strip Of Required Size With 2 Nos Earthing Terminals And Including Powder Coated Paint Finish Of Approved Shade Over Metal Surface Cleaned And Treated With Seven Tank Process Complete With Interconnections Etc As Per Specifications, As Required And As Below. 2346 ( Note:The Contractor May Select The Next Higher Fault Rating Of Mccb If It Is Not Readily Available , Without Any Extra Cost , As The Figure Indicated Within The Bracket Are Required Maxmum Fault Level Of The Panel. ) 2347 Feeder Pillar 2348 Design, Manufacturing, Supplying, Fixing In Position, Testing And Commissioning Of The Following Front Operated Front Access 2Mm Thick Crca Steel Enclosure Free Standing, Water, Dust And Vermin Proof Outdoor Type Feeder Pillars With Ip-55 Protection Hinged And Lockable Doors Complete With Interconnections Copper Crimping Lugs, Brass Glands Bonding To Earth And Painting, Suitable For Use At 415 Volts, 3 Phase 4 Wire 50 Hz System . The Panels Fault Withstanding Capacity Shall Be Of 25 Mva At 415 Volts. All Live Accessories Part Shall Be Shrouded And All Equipment Shall Be Finger Touch Proof. The Bus Bars Shall Be Of Colure Coded With Heat Shrinkable Pvc Insulated Sleeves. 2349 Feeder Pillar-3:Fortype-2 &Type-3 2350 Incomer 2351 1 No. 160A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 2352 1 No. Digital Multifunction Meter ( V+A+Hz ) With A Set Of Cast Resin Cts 160 / 5A. 2353 1 Set Of Phase Indicating Lamp With Mcb 2354 Bus Bars-I : 2355 200A Tpn Bus Bars Of Aluminium Alloy. 2356 For Emergency Supply 2357 1 No. 63A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 2358 1 Set Of On Indicating Lamp With Mcb 2359 Bus Bars-Ii : 2360 100A Tpn Bus Bars Of Aluminium Alloy. 2361 Out Going Bus-I : 2362 8 Nos. 63A 415V, 4P Mccb Of 15Ka . 2363 1 No. Mcb Space. 2364 Out Going Bus-Ii : 2365 5 Nos. 63A 415V, 4P Mcb Of 10Ka . 2366 1 No. 40A 415V, 4P Mcb Of 10Ka With 40A 4P Contactor & Timer Switch . 2367 2 Nos. 25A 415V, 4P Mcb Of 10Ka . 2368 1 No. Mcb Space. 2369 Feeder Pillar -2 For Vice Principal Residence, Girls Dorm, Boys Dorm. & Guest House. 2370 Incomer 2371 1 No. 100A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 2372 1 No. Digital Multifunction Meter ( V+A+Hz ) With A Set Of Cast Resin Cts 100 / 5A. 2373 1 Set Of Phase Indicating Lamp With Mcb 2374 Bus Bars-I : 2375 125A Tpn Bus Bars Of Aluminium Alloy. 2376 For Emergency Supply 2377 1 No. 63A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 2378 1 Set Of On Indicating Lamp With Mcb 2379 Bus Bars-Ii : 2380 100A Tpn Bus Bars Of Aluminium Alloy. 2381 Out Going Bus-I : 2382 4 Nos. 63A 415V, 4P Mccb Of 15Ka . 2383 1 No. Mcb Space. 2384 Out Going Bus-Ii : 2385 2 Nos. 63A 415V, 4P Mcb Of 10Ka . 2386 1 No. 40A 415V, 4P Mcb Of 10Ka With 40A 4P Contactor & Timer Switch . 2387 2 Nos. 25A 415V, 4P Mcb Of 10Ka . 2388 1 No. Mcb Space. 2389 1 No. Mcb Space. 2390 Meter Boards 2391 Supply, Installation, Testing And Commissioning Of M.V. Cubical Type Totally Enclosed Dust, Dump And Vermin Proof Meter Bords Complete With Bus Bars, Mv Danger Notice Plate, On Surface Isi Marked Electronic Kwh Meter, Indication Lamps, CtS, Interconnection With Suitable Capacity Aluminium Strips / Rods, Door Covers, Seperate Compartment For Each Meter, Glass Inspection Window, Connection Of Incoming And Outgoing Cables With Thimbles, Powder Coated Having Following Incoming And Outgoingmcbs Mccbs And Kwh Meters Complete As Required. 2392 Meter Boards - Type-Iii ( G+2 ) 2393 1 No. 125A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 2394 Bus Bars: 2395 200A Tpn Bus Bars Of Aluminium Alloy. 2396 Out Going: 2397 6 Nos. 40A Tpn Mcb Of 10Ka With Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 2398 6 No. 40A Dp Mcb Of 10Ka. 2399 Meter Boards -Dormitory Boys & Girls 2400 1 No. 100A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 2401 Bus Bars: 2402 150A Tpn Bus Bars Of Aluminium Alloy. 2403 Out Going: 2404 2 Nos. 40A Dp Mcb Of 10Ka With Space For Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 2405 7 Nos. 40A Dp Mcb Of 10Ka. 2406 Meter Boards - Type -Ii ( G+3 ) 2407 1 No. 125A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 2408 Bus Bars: 2409 200A Tpn Bus Bars Of Aluminium Alloy. 2410 Out Going: 2411 7 Nos. 40A Dp Mcb Of 10Ka Withelectronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 2412 7 No. 40A Dp Mcb Of 10Ka. 2413 Meter Boards - Vice Principal Residence 2414 1 No. 63A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 2415 Bus Bars: 2416 125A Tpn Bus Bars Of Aluminium Alloy. 2417 Out Going: 2418 1 Nos. 40A Dp Mcb Of 10Ka With Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 2419 1 No. 40A Dp Mcb Of 10Ka. 2420 Subhead - Ii - Earthing 2421 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 2422 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonary Enclosure With Cover Plate Having Locking Arrangement And Watering Watering Pipe 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 2423 Earthing With Cu. Earth Plate 600Mm X 600Mm X 3Mm Thick Includingaccesssories, And Providingmasonary Enclosurewith Cover Plate ( Ci Heavy Duty ) Having Locking Arrangement And Watering Pipe Pipe Of 2.7 Mtr Long Etc. With Charcoal Or Coke And Salt ) As Required. 2424 Supplying And Laying 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode, Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Refilling Etc. As Required. 2425 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 2 Nos Used For 50 X 5 For The Neutral Earthing Of Euipments ) 2426 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 2427 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Etc. As Required. 2428 Supplying, Fixing, Testing And Commissioning Of Following Bare Copper / Gi Flat Including All Necessary Fixing Accessories And Effecting Connections. 2429 50 Mm X 6 Mm Thick Cu Flat 2430 50 Mm X 6 M Thick Gi Flat 2431 Supply And Laying Medium Class Gi Pipe Under Road / Paved Areas / Wall Crossing Etc. Including Earth Excavations Refilling, Ramming And Making Good As Approved. 2432 150 Mm Dia Gi Pipe Class B 2433 Subhead - Iii - Supplying & Laying Of Cable 2434 L.T. Cables 2435 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Markedalong With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Includingexcavation And Refilling The Trench But Excluding Sand Cushioningand Protective Covering Etc., Complete As Required. 2436 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 2437 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) 2438 120 Mm Dia ( Od-120 Mm & Id-103 Mm Nominal ) 2439 160 Mm Dia ( Od-160 Mm & Id-135 Mm Nominal ) 2440 Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc. As Required. 2441 Above 35 Sq. Mm And Upto 95 Sq. Mm 2442 Above 95 Sq. Mm And Upto 185 Sq. Mm 2443 Above 185 Sq. Mm And Upto 400 Sq. Mm 2444 Laying Of One Number Pvc Insulated & Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 2445 Upto 35 Sq.Mm 2446 Above 35 Sq. Mm And Upto 95 Sq. Mm 2447 Above 95 Sq.Mm And Upto 185 Sq.Mm 2448 Above 185 Sq.Mm And Upto 400 Sq.Mm 2449 Supply Of Following Sizes Of Xlpe Insulatedaluminum Conductor Strip / Wire Armoured, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is-7098 Code And Technical Specifications. 2450 4 X 6 Sq. Mm 2451 4 X 10 Sq. Mm ( 28Mm ) 2452 4 X 16 Sq. Mm ( 28Mm ) 2453 3½ X 25 Sq. Mm ( 28Mm ) 2454 3½ X 35 Sq. Mm ( 32Mm ) 2455 3½ X 50 Sq. Mm ( 35Mm ) 2456 3½ X 150 Sq. Mm ( 50Mm ) 2457 3½ X 185 Sq. Mm ( 57Mm ) 2458 3½ X 240 Sq. Mm ( 62Mm ) 2459 3½ X 300 Sq. Mm ( 70Mm ) 2460 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Gradeas Required. 2461 4 X 6 Sq. Mm ( 28Mm ) 2462 4 X 10 Sq. Mm ( 28Mm ) 2463 4 X 16 Sq. Mm ( 28Mm ) 2464 3½ X 25 Sq. Mm ( 28Mm ) 2465 3½ X 35 Sq. Mm ( 32Mm ) 2466 3½ X 50 Sq. Mm ( 35Mm ) 2467 3½ X 150 Sq. Mm ( 50Mm ) 2468 3½ X 185 Sq. Mm ( 57Mm ) 2469 3½ X 240 Sq. Mm ( 62Mm ) 2470 3½ X 300 Sq. Mm ( 70Mm ) 2471 Providing, Laying And Fixing Following Dia Rcc Pipe Np2 Class ( Light Duty ) In Ground Complete With Rcc Collars, Jointing With Cement Mortar 1:2 ( 1 Cement : 2 Fine Sand ) Including Trenching ( 75 Cm Deep ) And Refilling Etc As Required. 2472 150 Mm Dia 2473 250 Mm Dia 2474 Supplying And Installing Following Size Of Perforated Paintedwith Powder Coating M.S. Cable Trays With Perforation Not Morethan 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts& Nuts, Painting Suspenders Etc As Required. 2475 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2476 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2477 450 Mm Width X 50 Mm Depth X 2 Mm Thickness 2478 Supplying And Installing Following Size Of Perforated Paintedwith Powder Coating M.S. Cable Trays Bends With Perforationnot More Than 17.5%, , Joined With Connectors, Suspended Fromthe Ceiling With M.S. Suspenders Including Bolts & Nuts, Paintingsuspenders Etc As Required. 2479 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2480 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2481 Supplying And Installing Following Size Of Perforated Paintedwith Powder Coating M.S. Cable Trays Tee With Perforation Notmore Than 17.5%, Joined With Connectors, Suspended From Theceiling With M.S. Suspenders Including Bolts & Nuts, Paintingsuspenders Etc As Required. 2482 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2483 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2484 Supplying And Installing Following Size Of Perforated Paintedwith Powder Coating M.S. Cable Trays Cross Member Withperforation Not More Than 17.5%, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts& Nuts, Painting Suspenders Etc As Required. 2485 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 2486 Sub Head -Iv :External Lighting 2487 Erection Of Metallic Pole Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 2488 Above 4.5 Metre And Upto 6.5 Metre 2489 Supplying, Installation, Testing And Commissioning Of Gate Light Fitting Suitable For 42 Watt Ip 65Led Having System Lumen Output Of Minimum 4200 Lumenscomplete With All Accessories And Lamp. Wipro Cat No.: 2490 Supplying, Installation, Testing And Commissioning Of 42W Led Street Lightip66 Led With High Performance Having System Lumen Output Of Minimum 9900 Lumens, Contemporary Designed Housing Made Of Die-Cast Aluminium, With Street Optic Lens For Uniform Light Distribution. Pf Better Than 0.9, Cri Better Than 70 Complete With All Accessories. Wipro Cat No.: Lr 02-102-Xxx-57-G2 Street Light 2491 Supplying, Installation, Testing And Commissioning Of 50W Ledsolar Street Light On 6 Meter Gi Octagonal Pole Having Compact, Aesthetic, Eco Friendly & Modern Integrated Solar Street Light In Extruted Aluminum Construction With High Efficiency Monocrystalline Silicon Photo Voltaic Panel, High Efficacy Smd Led 6500K Having Secondary Lens Optics For Street Lighting Distribution, High Performance Lithium Battery, Mppt Charge Controller & Intelligent Control Module / Sensor With Higher Reliability, Long Service Life, Suitable For Easy & Quick Installation. Wipro Cat No.:Lr 14-591-Xxx-65-Xx. 2492 Supply, Testing & Commissioning Of 6.0 Meter High G.Ioctagonal Pole ( Above Ground Level ) With Single / Double Arm As Per Requirement Of Suitable Length With Inbuilt Junction Box With 10A Sp Mcb, Connectors For Incoming / Outgoing Cable Connection And 300Mm X 300Mm X 20 Mm Thick Base Plate And Bracket ( Double Arm / Single Arm Whichever Required ) Complete In All Respect. 2493 Providing, Installation Of 200 X 150 X 125 Mm Polycarbonate Weather Proof ( Ip-55 ) Junction Box And Sp Mcb’S And Terminal Block. Supplying And Laying Cable Through Gi Pipe Upto Junction Box Including Excavation And Back Filling, Wiring With 2 X 2.5 Sq.Mm Pvc Insulated 1100 Volts Grade Copper Conductor Wires From Junction Box To Lighting Fixturecomplete. 2494 Supplying And Laying Cable Through Gi Pipe Upto Junction Box Including Excavation And Back Filling, Wiring With 2 X 2.5 Sq.Mm Pvc Insulated 1100 Volts Grade Copper Conductor Wires From Junction Box To Lighting Fixturecomplete. 2495 9.0 M High ( 7.5 M Above Ground ) Single Arm Sewaged Steel Tubular Pole, The Constructiopn Of The Pole Shall Be As Per Is 410 Sp - 26 With 450 Mm X 150 Mm Base Plate Welded At Top For Fixing The Flood Light, Complete As Per Requirement. Painted As Approved, Adopting Socket At Top For Fixture Mentioned Below, Base Plate 450 X 450 X 6Mm And Provision For Mounting Junction Box Etc. Complete As Required. 2496 Providing 600 X 600 X 1500 Mm Deep 1:3:6 Ratio Cement Concrete Including Excavation Shuttering Alignment Of Poles Casting Etc. Including 100Mm Thick Lean Concrete Shall Be Provided At The Bottom 2497 Supplying And Fixing Of Street Light Fixture 45 Watts Led Complete With Glass Cover Etc. And Its Wiring With 3 X 2.5 Sq.Mm Pvc Insulated Copper Wire From Junction Box Complete ( Eq To Bajaj Cat. No.-Brtfg 45 W Led ) . 2498 Supplying And Fixing Of 4.0 M High 40Mm Dia Gi Pole Painted As Approved, Adopting Socket At Top For Fixture With Base Plate As Required. 2499 Supplying And Fixing Of 20A Dp Junction Box With 2 No. Incoming And Outgoings Terminals And 2 Nos. Tap-Out Terminal With Mcb Complete 1 Set 2500 Supplying, Laying And Connecting 2 Nos 2.5. Sq.Mm Copper Conductor Pvc Insulated 1100 Volts Grade Wires From Terminal Block To Light Fixture Along With End Terminations And Including The Cost Of 1 No. 2.5 Sq.Mm Pvc Insulated Copper Wire For Earthing Of The Light Fixture Complete As Required. 2501 Sub Head -V :Earthing And Miscellaneous Items ( Non Dsr Items ) 2502 Supplying And Fixing Of High Voltage Insulation Mat Of Class B Having 11 Kv Dielectric Strength, 1000Mm Width And Thickness Of 2.5Mm Isi Approved As Required Including Cutting To Required Lengths. 2503 Supplying And Fixing Of High Voltage Insulation Mat Of Class B Having 1.1 Kv Dielectric Strength, 1000Mm Width And Thickness Of 2.0 Mm Isi Approved As Required Including Cutting To Required Lengths. 2504 Supplying Of 11 Kv Hand Gloves As Required. 2505 Supplying Of Resuciation Kit Coomplete With Instruction Manual Etc. As Required. 2506 Supplying Of Fire Bucket Painted Red With Stand And Approved Quality Conforming To Is:254 / 1974 2507 Supplying And Fixing Of Powder Fire Extinguisher ( Stored Pressure Type ) Capacity 06 Kg Duly Isi Marked Conforming To Is: 15683:2006, With Is 14609, Isi Marked Abc Powder Complete With Squeeze Grip Release Valve, Discharge Pipe, Locking Arrangement, Pressure Gauge & Suitable M.S. Bracket As Required. 2508 Supplying Of First Aid Box As Approved Complete With Standard Kit As Prescribed By Indian Red Cross. 2509 Supplying And Fixing Of Shock Treatment Chart Written In English And Local Language Duly Framed In Glass As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
30.
Housing Urban and Rular Development #9440730 Technical Bid
Tender For Construction Of Phase-B Work At Jnv Howrah ( W.B ) , 1 0.625 BoyS Dormitory With 3 Nos. Warden Residence 2 Earth Work 3 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil 4 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 5 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 6 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 7 Concrete Work 8 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 9 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 10 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 11 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation, Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 12 Reinforced Cement Concrete 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 14 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 15 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 16 Lintels, Beams, Plinth Beams, Girders, Bressumers 17 Columns, Pillars, Piers, Abutments, Posts And Struts. 18 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 19 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 20 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 21 Pile Work 22 Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) 400 Mm Dia Piles 23 Vertical Load Testing Of Piles In Accordance With Is 2911 ( Part Iv ) Including Installation Of Loading Platform By Kentledge / Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Note: 1. Initial And Routine Load Test Shall Not Be Carried Out By Dynamic Method Of Testing.Note: 2. Testing Agency Shall Submit The Design Of Loading Platform For The Approval Of Engineer-In-Charge. 24 Single Pile Upto 50 Tonne Safe Capacity 25 Initial Test ( Test Load 2.5 Times The Safecapacity ) 26 Routine Test ( Test Load 1.5 Times The Safecapacity ) 27 Group Of Two Or More Piles Upto 50 Tonne Safe Capacity 28 Initial Test ( Test Load 2.5 Times The Safecapacity ) 29 Routine Test ( Test Load 1.5 Times The Safecapacity ) 30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 31 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 32 All Works Upto Plinth Level 33 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 34 ( I ) R.C.C. Work In Footing 35 ( Iii ) R.C.C. Work In Columns 36 All Works Above Plinth Level Upto Floor V Level 37 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 38 ( I ) R.C.C. Work In Lintel 39 ( Ii ) R.C.C. Work In Beam 40 ( Iii ) R.C.C. Work In Columns 41 ( Iv ) R.C.C. Work In Slab 42 Expansion Joint Treatment 43 Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas That Commodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions. The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) . 44 Floor Joint Of 100 Mm Gap 45 Providing And Fixing Of Expansion Joint System Related With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints Systemsuitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimal Exposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) . 46 Wall Joint Of 100 Mm Gap 47 Providing And Fixing Of Expansion Joint System Of Approved Make And Manufacture For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates As Per Astm B221-02. The System Shall Be Such That It Provides Water Tight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To 48 Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) 49 Roof Joint Of 100 Mm Gap 50 Masonry Work 51 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 52 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 53 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 54 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. ( The Payment Of Rccband And Reinforcement Shall Be Made For Seperately ) . 55 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Foundation And Plinth In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 56 Cladding Work 57 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 58 Granite Stone Slab Colour Black, Cherry / Ruby Red 59 Area Of Slab Upto 0.50 Sqm 60 Area Of Slab Over 0.50 Sqm 61 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 62 Granite Work 63 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 64 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 65 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 66 Wood And Pvc Work 67 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 68 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 69 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 70 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 71 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 72 300 Mm Weighing Not Less Than 200 Gms 73 250 Mm Weighing Not Less Than 150 Gms 74 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 75 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 76 Providing And Fixing Pvc Rigid Foam Sheet 1 Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Based Adhesive. 77 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size Kiln Seasoned And Chemically Treated Hollock Wood 78 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 79 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 80 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 81 300 X 10Mm 82 150 X 10Mm 83 Steel Work 84 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 85 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 86 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 87 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 88 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 89 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. 90 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 91 Flooring 92 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 93 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Medium Shade Pigment Using 50% White Cement 50% Grey Cement 94 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 95 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 96 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conformingto Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Includingpointing The Joints With White Cement And Matching Pigment Etc., Complete. 97 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 98 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 99 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 100 P & Laying Cement Concrete 101 Finishing 102 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 103 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 104 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 105 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 106 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 107 Steel Painting:Applying Priming Coat: 108 With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 109 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 110 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: Two Or More Coats On New Work. 111 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 112 Water Proofing 113 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 114 Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete : 115 With Residual Type Petroleum Bitumen Of Grade Vg -10 116 Supply & Fixing Of Prepainted Coloured Trapezoidal Or Approved Profiled Sheeting 1000-1020 Mm Cover Width, 28-30 Mm High Crests With Subtle Square Fluting In The Five Pan At Nominal 190-255 Mm ( As Approved By Eic ) Centre-To-Centre Manufactured Out Of 0.50 Mm Tct Hi-Tensile Prepainted Zincalume / Galvalume Steel ( Az-150 Gsm. Aluminium –Zinc Alloy Metallic Coating Of Total Both Sides 550 Mpa Yield Stress As Per As-1397 ) . Colour / Exterior Coat Of Rmp 20 Micron Top Coat Applied Over 5 Micron Primer And A 5 Micron Polyester Back Coat Applied Over 5 Microns Primer Or Equivalent Coating / Painting. The Sheet Shall Have Wide Pans With Stiffening Ribs For Effective Water Shedding And Special Male / Female Ends With Full Return Legs On Side Laps For Purlin Support. The Male End Of The Sheet Shall Have Anti-Capillary Flute At Side Laps To Prevent Leakages. The Sheet Shall Be Fixed By Means Of Anti Corrosive Approved Make Rust Shield ( Epoxy Polymer ) Coated Self-Drilling Self Tapping Fasteners 12-14 X 55 Mm With Epdm Seals Through Crest For Roofing And 12-24 X 20 Mm Through Valley ( Pans ) For Wall Cladding. The Sheet Shall Be Supplied In Lengths Maximum Up To 6-12 Meter Long To Suit Site Dimensions. The Scope Includes All Sealing Of Joint, Curves, Edges Or Other Accessories With Silicon Sealant. 117 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 118 2.1 Mtht. Boundary Wall 119 Plumbing Internal Estimate ( 0.625 Unit Boys Dormitory With 3 Nos Warden Residence ) 120 Sub Head– I Sanitary Installation 121 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 122 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 123 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 124 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 125 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 126 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 127 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 128 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 129 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 130 Providing And Fixing Toilet Paper Holder : 131 C.P. Brass 132 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 133 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 134 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 135 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 136 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 137 Kitchen Sink With Drain Board 138 510X1040 Mm Bowl Depth 250Mm 139 Kitchen Sink Without Drain Board 140 610X460 Mm Bowl Depth 200 Mm 141 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 142 Size 450X300x150 Mm 143 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 144 Flexible Pipe 145 40 Mm Dia 146 Providing And Fixing Soil, Waste And Vent Pipes : 147 100 Mm Dia 148 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 149 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 150 100 Mm 151 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 152 Providing And Fixing Plain Bend Of Required Degree. 153 100 Mm 154 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 155 Providing And Fixing Heel Rest Sanitary Bend 156 100 Mm Dia 157 Sand Cast Iron S&S As Per Is - 3989 158 Providing And Fixing Double Equal Plain Junction Of Required Degree 159 100X100x100x100 Mm 160 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 161 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 162 100X100x100 Mm 163 Sand Cast Iron S&S As Per Is: 3989 164 Providing And Fixing Single Equal Plain Junction Of Required Degree 165 100X100x100 Mm 166 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 167 Providing And Fixing Terminal Guard: 168 100 Mm 169 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 170 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 171 100 Mm 172 S S 304 Grade Coupling With Epdm Rubber Gasket 173 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 174 100 Mm 175 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 176 100 Mm Diameter Pipe 177 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 178 100 Mm Diameter Pipe 179 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 180 32 Mm Dia. Nominal Bore 181 40 Mm Dia. Nominal Bore 182 50 Mm Dia. Nominal Bore 183 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 184 100 Mm Inlet And 100 Mm Outlet 185 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 186 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 187 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 188 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 189 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 190 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 191 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 192 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 193 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 194 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 195 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 196 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes.110 Mm Diameter 197 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 198 Coupler 199 110 Mm 200 Single Tee With Door 201 110X110x110 Mm 202 Bend 87.5° 203 110 Mm 204 Shoe ( Plain ) 205 110 Mm Shoe 206 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 207 110 Mm 208 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 209 110 Mm Outer Dia 210 50 Mm Outer Dia 211 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 212 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 213 Sub Head– Ii Water Supply 214 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 215 Internal Work – Exposed On Wall. 216 20 Mm Nominal Outer Dia Pipes 217 25 Mm Nominal Outer Dia Pipes 218 32 Mm Nominal Outer Dia Pipes 219 40 Mm Nominal Outer Dia Pipes 220 50 Mm Nominal Outer Dia Pipes 221 65 Mm Nominal Outer Dia Pipes 222 80 Mm Nominal Outer Dia Pipes 223 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 224 Concealed Including Cutting Chases And Making Good The Wall Etc. 225 15 Mm Nominal Outer Dia Pipes 226 20 Mm Nominal Outer Dia Pipes 227 25 Mm Nominal Outer Dia Pipes 228 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 229 20 Mm Dia. Nominal Bore 230 25 Mm Dia. Nominal Bore 231 32 Mm Dia. Nominal Bore 232 40 Mm Dia. Nominal Bore 233 50 Mm Dia. Nominal Bore 234 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 235 25 Mm Nominal Bore 236 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 237 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 238 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 239 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 240 15 Mm Nominal Bore 241 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 242 15 Mm Nominal Bore 243 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 244 15Mm Nominal Bore 245 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 246 45 Cm Length 247 15 Mm Nominal Bore 248 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 249 150 Mm Diameter 250 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 251 ( A ) 15 Mm Nominal Dia 252 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 253 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 254 Upto 50 Mm Dia. Nominal Bore 255 Subhead– Iii Drainage 256 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 257 150 Mm Diameter 258 200 Mm Diameter 259 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 260 180X150 Mm Size P Type 261 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 262 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 263 150 Mm Dia. R.C.C. Pipe 264 250 Mm Dia. R.C.C. Pipe 265 300 Mm Dia. R.C.C. Pipe 266 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 267 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 268 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 269 Extra Depth Formanhole 90X80 Cm 270 With Fpsbricks Class Designation 7.5 271 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 272 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 273 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 274 Electrical Works 0.625Boys Dormitory With 3 Nos. Warden Residence 275 Sub Head - I: Circuit Cum Point Wiring 276 Switch Control Light Points 277 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 278 Group C 279 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 280 Group C 281 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 282 Group C 283 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 284 Group C 285 Mcb Control Light Points 286 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 287 Primary Point Controlled By One Mcb. 288 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 289 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 290 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 291 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 292 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 293 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 294 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 295 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 296 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 297 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 298 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 299 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 300 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 301 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 302 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 303 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 304 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 305 Telephone Socket Outlet 306 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 307 1 Or 2 Module ( 75Mmx75mm ) 308 6 Module ( 78Mm X 205 Mm X 50 Mm ) 309 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 310 3 Pin , 5 / 6 Amps Socket Outlet 311 5 / 6 Amps Switch 312 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 313 25 Mm 314 32 Mm 315 Subhead -Ii - Fittings & Fixtures 316 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 317 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 318 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 319 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 320 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 321 Supply, Installation, Testing And Commissioning Of150 W Chandelier 322 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 323 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 324 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 325 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 326 Subhead - Iii - Distribution Boards 327 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 328 6 Way, Double Door 329 8 Way, Double Door 330 12 Way, Double Door 331 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 332 4 Way ( 4 + 12 ) , Double Door 333 6 Way ( 4 + 18 ) , Double Door 334 8 Way ( 4 + 24 ) , Double Door 335 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 336 12 Way ( 4 + 36 ) , Double Door 337 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 338 Single Pole 339 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 340 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 341 63 A 342 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 343 63 A 344 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 345 Sub Head-Iv , Lightning Conductor 346 Lightning Conductor 347 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 348 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 349 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 350 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 351 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 352 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 353 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 354 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 355 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 356 0.375 GirlS Dormitory With 3 Nos. Warden Residence ( G+2 ) 357 Earth Work 358 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil 359 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 360 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 361 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 362 Concrete Work 363 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zoneiii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 364 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 365 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 366 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 367 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation, Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 368 Reinforced Cement Concrete 369 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 370 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 371 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 372 Lintels, Beams, Plinth Beams, Girders, Bressumers 373 Columns, Pillars, Piers, Abutments, Posts And Struts. 374 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 375 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 376 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 377 Pile Work 378 Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) 400 Mm Dia Piles 379 Vertical Load Testing Of Piles In Accordance With Is 2911 ( Part Iv ) Including Installation Of Loading Platform By Kentledge / Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Note: 1. Initial And Routine Load Test Shall Not Be Carried Out By Dynamic Method Of Testing.Note: 2. Testing Agency Shall Submit The Design Of Loading Platform For The Approval Of Engineer-In-Charge. 380 Single Pile Upto 50 Tonne Safe Capacity 381 Initial Test ( Test Load 2.5 Times The Safecapacity ) 382 Routine Test ( Test Load 1.5 Times The Safecapacity ) 383 Group Of Two Or More Piles Upto 50 Tonne Safe Capacity 384 Initial Test ( Test Load 2.5 Times The Safecapacity ) 385 Routine Test ( Test Load 1.5 Times The Safecapacity ) 386 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 387 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 388 All Works Upto Plinth Level 389 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 390 ( I ) R.C.C. Work In Footing 391 ( Ii ) R.C.C. Work In Beam 392 ( Iii ) R.C.C. Work In Columns 393 All Works Above Plinth Level Upto Floor V Level 394 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 395 ( I ) R.C.C. Work In Lintel 396 ( Ii ) R.C.C. Work In Beam 397 ( Iii ) R.C.C. Work In Columns 398 ( Iv ) R.C.C. Work In Slab 399 Expansion Joint Treatment 400 Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas That Commodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions. The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) . 401 Floor Joint Of 100 Mm Gap 402 Providing And Fixing Of Expansion Joint System Related With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints Systemsuitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimal Exposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) . 403 Wall Joint Of 100 Mm Gap 404 Providing And Fixing Of Expansion Joint System Of Approved Make And Manufacture For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates As Per Astm B221-02. The System Shall Be Such That It Provides Water Tight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To 405 Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) 406 Roof Joint Of 100 Mm Gap 407 Masonry Work 408 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 409 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 410 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 411 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. ( The Payment Of Rccband And Reinforcement Shall Be Made For Seperately ) . 412 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Foundation And Plinth In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 413 Cladding Work 414 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 415 Granite Stone Slab Colour Black, Cherry / Ruby Red 416 Area Of Slab Upto 0.50 Sqm 417 Area Of Slab Over 0.50 Sqm 418 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 419 Granite Work 420 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 421 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 422 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 423 Wood And Pvc Work 424 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 425 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 426 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 427 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 428 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 429 300 Mm Weighing Not Less Than 200 Gms 430 250 Mm Weighing Not Less Than 150 Gms 431 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 432 Providing And Fixing Pvc Rigid Foam Sheet 1 Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Based Adhesive. 433 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size Kiln Seasoned And Chemically Treated Hollock Wood 434 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 435 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 436 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 437 300 X 10Mm 438 150 X 10Mm 439 Steel Work 440 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 441 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 442 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 443 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 444 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 445 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. 446 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 447 Flooring 448 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 449 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Medium Shade Pigment Using 50% White Cement 50% Grey Cement 450 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 451 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 452 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conformingto Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Includingpointing The Joints With White Cement And Matching Pigment Etc., Complete. 453 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 454 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 455 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 456 P & Laying Cement Concrete 457 Finishing 458 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 459 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 460 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 461 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 462 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 463 Steel Painting:Applying Priming Coat: 464 With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 465 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 466 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: Two Or More Coats On New Work. 467 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 468 Water Proofing 469 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 470 Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete : 471 With Residual Type Petroleum Bitumen Of Grade Vg -10 472 Supply & Fixing Of Prepainted Coloured Trapezoidal Or Approved Profiled Sheeting 1000-1020 Mm Cover Width, 28-30 Mm High Crests With Subtle Square Fluting In The Five Pan At Nominal 190-255 Mm ( As Approved By Eic ) Centre-To-Centre Manufactured Out Of 0.50 Mm Tct Hi-Tensile Prepainted Zincalume / Galvalume Steel ( Az-150 Gsm. Aluminium –Zinc Alloy Metallic Coating Of Total Both Sides 550 Mpa Yield Stress As Per As-1397 ) . Colour / Exterior Coat Of Rmp 20 Micron Top Coat Applied Over 5 Micron Primer And A 5 Micron Polyester Back Coat Applied Over 5 Microns Primer Or Equivalent Coating / Painting. The Sheet Shall Have Wide Pans With Stiffening Ribs For Effective Water Shedding And Special Male / Female Ends With Full Return Legs On Side Laps For Purlin Support. The Male End Of The Sheet Shall Have Anti-Capillary Flute At Side Laps To Prevent Leakages. The Sheet Shall Be Fixed By Means Of Anti Corrosive Approved Make Rust Shield ( Epoxy Polymer ) Coated Self-Drilling Self Tapping Fasteners 12-14 X 55 Mm With Epdm Seals Through Crest For Roofing And 12-24 X 20 Mm Through Valley ( Pans ) For Wall Cladding. The Sheet Shall Be Supplied In Lengths Maximum Up To 6-12 Meter Long To Suit Site Dimensions. The Scope Includes All Sealing Of Joint, Curves, Edges Or Other Accessories With Silicon Sealant. 473 Providing And Filling Of Aac Lightweight Broken Blocks Sunken Portions. 474 2.1 Mtht. Boundary Wallwith Concertina Coil 475 2.1 Mtht. Boundary Wall 476 Plumbing Internal Estimate ( 0.375 Unit Girls Dormitory With 3 Nos Warden Residence ) 477 Sub Head– I Sanitary Installation 478 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 479 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 480 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 481 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 482 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 483 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 484 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 485 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 486 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 487 Providing And Fixing Toilet Paper Holder : 488 C.P. Brass 489 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 490 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 491 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 492 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 493 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 494 Kitchen Sink With Drain Board 495 510X1040 Mm Bowl Depth 250Mm 496 Kitchen Sink Without Drain Board 497 610X460 Mm Bowl Depth 200 Mm 498 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 499 Size 450X300x150 Mm 500 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 501 Flexible Pipe 502 40 Mm Dia 503 Providing And Fixing Soil, Waste And Vent Pipes : 504 100 Mm Dia 505 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 506 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 507 100 Mm 508 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 509 Providing And Fixing Plain Bend Of Required Degree. 510 100 Mm 511 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 512 Providing And Fixing Heel Rest Sanitary Bend 513 100 Mm Dia 514 Sand Cast Iron S&S As Per Is - 3989 515 Providing And Fixing Double Equal Plain Junction Of Required Degree 516 100X100x100x100 Mm 517 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 518 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 519 100X100x100 Mm 520 Sand Cast Iron S&S As Per Is: 3989 521 Providing And Fixing Single Equal Plain Junction Of Required Degree 522 100X100x100 Mm 523 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 524 Providing And Fixing Terminal Guard: 525 100 Mm 526 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 527 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 528 100 Mm 529 S S 304 Grade Coupling With Epdm Rubber Gasket 530 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 531 100 Mm 532 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 533 100 Mm Diameter Pipe 534 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 535 100 Mm Diameter Pipe 536 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 537 32 Mm Dia. Nominal Bore 538 40 Mm Dia. Nominal Bore 539 50 Mm Dia. Nominal Bore 540 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 541 100 Mm Inlet And 100 Mm Outlet 542 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 543 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 544 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 545 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 546 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 547 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 548 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 549 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 550 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 551 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 552 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 553 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 554 Coupler 555 110 Mm 556 Single Tee With Door 557 110X110x110 Mm 558 Bend 87.5° 559 110 Mm 560 Shoe ( Plain ) 561 110 Mm Shoe 562 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 563 110 Mm 564 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 565 110 Mm Outer Dia 566 50 Mm Outer Dia 567 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 568 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 569 Sub Head– Ii Water Supply 570 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 571 Internal Work – Exposed On Wall. 572 20 Mm Nominal Outer Dia Pipes 573 25 Mm Nominal Outer Dia Pipes 574 32 Mm Nominal Outer Dia Pipes 575 40 Mm Nominal Outer Dia Pipes 576 50 Mm Nominal Outer Dia Pipes 577 65 Mm Nominal Outer Dia Pipes 578 80 Mm Nominal Outer Dia Pipes 579 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 580 Concealed Including Cutting Chases And Making Good The Wall Etc. 581 15 Mm Nominal Outer Dia Pipes 582 20 Mm Nominal Outer Dia Pipes 583 25 Mm Nominal Outer Dia Pipes 584 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 585 20 Mm Dia. Nominal Bore 586 25 Mm Dia. Nominal Bore 587 32 Mm Dia. Nominal Bore 588 40 Mm Dia. Nominal Bore 589 50 Mm Dia. Nominal Bore 590 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 591 25 Mm Nominal Bore 592 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 593 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 594 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 595 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 596 15 Mm Nominal Bore 597 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 598 15 Mm Nominal Bore 599 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 600 15Mm Nominal Bore 601 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 602 45 Cm Length 603 15 Mm Nominal Bore 604 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 605 150 Mm Diameter 606 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 607 ( A ) 15 Mm Nominal Dia 608 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 609 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 610 Upto 50 Mm Dia. Nominal Bore 611 Subhead– Iii Drainage 612 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 613 150 Mm Diameter 614 200 Mm Diameter 615 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 616 180X150 Mm Size P Type 617 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 618 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 619 150 Mm Dia. R.C.C. Pipe 620 250 Mm Dia. R.C.C. Pipe 621 300 Mm Dia. R.C.C. Pipe 622 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 623 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 624 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 625 Extra Depth Formanhole 90X80 Cm 626 With Fpsbricks Class Designation 7.5 627 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 628 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 629 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 630 Electrical Works 0.375 Girls Dormitory With 3 Nos. Warden Residence 631 Sub Head - I: Circuit Cum Point Wiring 632 Switch Control Light Points 633 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 634 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 635 Group C 636 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 637 Group C 638 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 639 Group C 640 Mcb Control Light Points 641 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 642 Primary Point Controlled By One Mcb. 643 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 644 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 645 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 646 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 647 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 648 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 649 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 650 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 651 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 652 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 653 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 654 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 655 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 656 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 657 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 658 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 659 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 660 Telephone Socket Outlet 661 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 662 1 Or 2 Module ( 75Mmx75mm ) 663 6 Module ( 78Mm X 205 Mm X 50 Mm ) 664 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 665 3 Pin , 5 / 6 Amps Socket Outlet 666 5 / 6 Amps Switch 667 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 668 25 Mm 669 32 Mm 670 Subhead -Ii - Fittings & Fixtures 671 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 672 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 673 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 674 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 675 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 676 Supply, Installation, Testing And Commissioning Of150 W Chandelier 677 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 678 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 679 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 680 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 681 Subhead - Iii - Distribution Boards 682 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 683 6 Way, Double Door 684 8 Way, Double Door 685 12 Way, Double Door 686 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 687 4 Way ( 4 + 12 ) , Double Door 688 6 Way ( 4 + 18 ) , Double Door 689 8 Way ( 4 + 24 ) , Double Door 690 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 691 12 Way ( 4 + 36 ) , Double Door 692 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 693 Single Pole 694 Single Pole Neutral 695 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 696 40 A 697 63 A 698 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 699 25 A 700 40 A 701 63 A 702 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 703 25 A 704 40 A 705 63 A 706 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 707 Sub Head-Iv , Lightning Conductor 708 Lightning Conductor 709 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 710 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 711 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 712 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 713 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 714 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 715 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 716 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 717 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 718 [ Type-4 Vice Principal Residence+Guest House ] 719 Earth Work 720 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 721 All Kinds Of Soil 722 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 723 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 724 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 725 Concrete Work 726 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zoneiii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 727 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 728 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 729 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed Andconsolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 730 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 731 Reinforced Cement Concrete 732 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 733 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 734 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 735 Lintels, Beams, Plinth Beams, Girders, Bressumers 736 Columns, Pillars, Piers, Abutments, Posts And Struts. 737 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 738 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 739 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 740 Pile Work 741 Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) 400 Mm Dia Piles 742 Vertical Load Testing Of Piles In Accordance With Is 2911 ( Part Iv ) Including Installation Of Loading Platform By Kentledge / Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Note: 1. Initial And Routine Load Test Shall Not Be Carried Out By Dynamic Method Of Testing.Note: 2. Testing Agency Shall Submit The Design Of Loading Platform For The Approval Of Engineer-In-Charge. 743 Single Pile Upto 50 Tonne Safe Capacity 744 Initial Test ( Test Load 2.5 Times The Safecapacity ) 745 Routine Test ( Test Load 1.5 Times The Safecapacity ) 746 Group Of Two Or More Piles Upto 50 Tonne Safe Capacity 747 Initial Test ( Test Load 2.5 Times The Safecapacity ) 748 Routine Test ( Test Load 1.5 Times The Safecapacity ) 749 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 750 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarseaggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures Inrecommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairingstrength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Contentin Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 751 All Works Upto Plinth Level 752 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 753 ( I ) R.C.C. Work In Footing 754 ( Ii ) R.C.C. Work In Beam 755 ( Iii ) R.C.C. Work In Columns 756 All Works Above Plinth Level Upto Floor V Level 757 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 758 ( I ) R.C.C. Work In Lintel 759 ( Ii ) R.C.C. Work In Beam 760 ( Iii ) R.C.C. Work In Columns 761 ( Iv ) R.C.C. Work In Slab 762 Masonry Work 763 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 764 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 765 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Superstructure Above Plinth Level Up To Floor V Levelin : 766 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 767 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. ( The Payment Of Rccband And Reinforcement Shall Be Made For Seperately ) . 768 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Foundation And Plinth In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 769 Cladding Work 770 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 771 Granite Stone Slab Colour Black, Cherry / Ruby Red 772 Area Of Slab Upto 0.50 Sqm 773 Area Of Slab Over 0.50 Sqm 774 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 775 Granite Work 776 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 777 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 778 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 779 Wood And Pvc Work 780 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Bothfaces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 781 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 782 Extra For Cutting Rebate In Flush Door Shutters ( Total Area Of The Shutter To Be Measured ) . 783 P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. 784 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 785 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 786 300 Mm Weighing Not Less Than 200 Gms 787 250 Mm Weighing Not Less Than 150 Gms 788 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 789 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Finecellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Selftapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As PermanufacturerS Specification And Direction Of Engineer-In-Charge. 790 Providing And Fixing Pvc Rigid Foam Sheet 1 Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Basedadhesive. 791 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 1.0 Mm Thick 792 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size, Kiln Seasoned And Chemically Treated Hollock Wood 793 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 794 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 795 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 796 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 797 300 X 10Mm 798 150 X 10Mm 799 Providing And Fixing 6Mm Thick Both Sides Pre-Laminated Cement Bonded Wood Particle Board As Per Is : 15786:2008 Of Approved Brand And Shade With Suitable Full Threaded Steel Screws Etc. On The Backing Of Racks, Drawer, Cupboard, Kitchen Cabinet Under Kitchen Counter Etc. All Complete As Per Direction Of Engineer In-Charge. 800 Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressedbwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges ( Hydraulic Type ) Etc. Complete As Per Direction Of Engineer In-Charge. ( Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately ) 801 Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approvedbrand Boxes, Shelves, Racks, Almirah, Cupboard And Drawer Etc. Including Necessary Nails, Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 802 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 200 Mm 803 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 100 Mm For Kitchen Cabinets 804 Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges ( Hydraulic Type ) Of Approved Make / Brand Tocupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete Asperdirection Of Engineer-In-Charge 805 Providing And Fixing Stainless Steel Soft Closing Heavy Type Telescopic Drawer Channels Of Approved Make 500 Mm Long With Screws Etc. Complete As Per Directions Of Engineer- In-Charge 806 Ss Hanging Rod For Cb 807 Providing And Fixing 25 Mm Dia. Ss Pipe Hanging Rods With Ss Brackets : 808 Steel Work 809 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 810 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 811 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 812 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 813 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steelprimer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 814 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 815 Flooring 816 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 817 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 818 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Requiredthickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600 X 600 Mm 819 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm. 820 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm 821 Roofing 822 Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete : 823 With Residual Type Petroleum Bitumen Of Grade Vg -10 824 Supply & Fixing Of Prepainted Coloured Trapezoidal Or Approved Profiled Sheeting 1000-1020 Mm Cover Width, 28-30 Mm High Crests With Subtle Square Fluting In The Five Pan At Nominal 190-255 Mm ( As Approved By Eic ) Centre-To-Centre Manufactured Out Of 0.50 Mm Tct Hi-Tensile Prepainted Zincalume / Galvalume Steel ( Az-150 Gsm. Aluminium –Zinc Alloy Metallic Coating Of Total Both Sides 550 Mpa Yield Stress As Per As-1397 ) . Colour / Exterior Coat Of Rmp 20 Micron Top Coat Applied Over 5 Micron Primer And A 5 Micron Polyester Back Coat Applied Over 5 Microns Primer Or Equivalent Coating / Painting. The Sheet Shall Have Wide Pans With Stiffening Ribs For Effective Water Shedding And Special Male / Female Ends With Full Return Legs On Side Laps For Purlin Support. The Male End Of The Sheet Shall Have Anti-Capillary Flute At Side Laps To Prevent Leakages. The Sheet Shall Be Fixed By Means Of Anti Corrosive Approved Make Rust Shield ( Epoxy Polymer ) Coated Self-Drilling Self Tapping Fasteners 12-14 X 55 Mm With Epdm Seals Through Crest For Roofing And 12-24 X 20 Mm Through Valley ( Pans ) For Wall Cladding. The Sheet Shall Be Supplied In Lengths Maximum Up To 6-12 Meter Long To Suit Site Dimensions. The Scope Includes All Sealing Of Joint, Curves, Edges Or Other Accessories With Silicon Sealant. 825 Finishing 826 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 827 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 828 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 829 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 830 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 831 Applying Priming Coat: 832 With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 833 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 834 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 835 Two Or More Coats On New Work. 836 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 837 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 838 Plumbing Internal Estimate ( Vice Principal& Guest House Residence ) 839 Sub Head– I Sanitary Installation 840 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 841 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 842 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 843 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 844 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 845 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 846 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 847 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 848 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 849 Providing And Fixing Toilet Paper Holder : 850 C.P. Brass 851 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washo Asapprovedbyengineer-In Charge 852 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 853 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 854 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 855 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 856 Kitchen Sink With Drain Board 857 510X1040 Mm Bowl Depth 250Mm 858 Applying Priming Coat: 859 610X460 Mm Bowl Depth 200 Mm 860 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 861 Size 450X300x150 Mm 862 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 863 Flexible Pipe 864 40 Mm Dia 865 Providing And Fixing Soil, Waste And Vent Pipes : 866 100 Mm Dia 867 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 868 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 869 100 Mm 870 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 871 Providing And Fixing Plain Bend Of Required Degree. 872 100 Mm 873 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 874 Providing And Fixing Heel Rest Sanitary Bend 875 100 Mm Dia 876 Sand Cast Iron S&S As Per Is - 3989 877 Providing And Fixing Double Equal Plain Junction Of Required Degree 878 100X100x100x100 Mm 879 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 880 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 881 100X100x100 Mm 882 Sand Cast Iron S&S As Per Is: 3989 883 Providing And Fixing Single Equal Plain Junction Of Required Degree 884 100X100x100 Mm 885 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 886 Providing And Fixing Terminal Guard: 887 100 Mm 888 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 889 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 890 100 Mm 891 S S 304 Grade Coupling With Epdm Rubber Gasket 892 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 893 100 Mm 894 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 895 100 Mm Diameter Pipe 896 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 897 100 Mm Diameter Pipe 898 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 899 32 Mm Dia. Nominal Bore 900 40 Mm Dia. Nominal Bore 901 50 Mm Dia. Nominal Bore 902 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 903 100 Mm Inlet And 100 Mm Outlet 904 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 905 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 906 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 907 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 908 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 909 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 910 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 911 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 912 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 913 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 914 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 915 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 916 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 917 Coupler 918 110 Mm 919 Single Tee With Door 920 110X110x110 Mm 921 Bend 87.5° 922 110 Mm 923 Shoe ( Plain ) 924 110 Mm Shoe 925 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 926 110 Mm 927 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 928 110 Mm Outer Dia 929 50 Mm Outer Dia 930 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 931 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 932 Sub Head– Ii Water Supply 933 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 934 Internal Work – Exposed On Wall. 935 20 Mm Nominal Outer Dia Pipes 936 25 Mm Nominal Outer Dia Pipes 937 32 Mm Nominal Outer Dia Pipes 938 40 Mm Nominal Outer Dia Pipes 939 50 Mm Nominal Outer Dia Pipes 940 65 Mm Nominal Outer Dia Pipes 941 80 Mm Nominal Outer Dia Pipes 942 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 943 Concealed Including Cutting Chases And Making Good The Wall Etc. 944 15 Mm Nominal Outer Dia Pipes 945 20 Mm Nominal Outer Dia Pipes 946 25 Mm Nominal Outer Dia Pipes 947 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 948 20 Mm Dia. Nominal Bore 949 25 Mm Dia. Nominal Bore 950 32 Mm Dia. Nominal Bore 951 40 Mm Dia. Nominal Bore 952 50 Mm Dia. Nominal Bore 953 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 954 25 Mm Nominal Bore 955 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 956 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 957 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 958 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 959 15 Mm Nominal Bore 960 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 961 15 Mm Nominal Bore 962 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 963 15Mm Nominal Bore 964 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 965 45 Cm Length 966 15 Mm Nominal Bore 967 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 968 150 Mm Diameter 969 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 970 ( A ) 15 Mm Nominal Dia 971 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 972 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 973 Subhead– Iii Drainage 974 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 975 150 Mm Diameter 976 200 Mm Diameter 977 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 978 180X150 Mm Size P Type 979 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 980 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 981 150 Mm Dia. R.C.C. Pipe 982 250 Mm Dia. R.C.C. Pipe 983 300 Mm Dia. R.C.C. Pipe 984 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 985 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 986 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 987 Extra Depth Formanhole 90X80 Cm 988 With Fpsbricks Class Designation 7.5 989 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 990 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 991 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 992 Electrical Works ( Vice Principal & Guest House ) 993 Sub Head - I: Circuit Cum Point Wiring 994 Switch Control Light Points 995 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 996 Group C 997 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 998 Group C 999 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1000 Group C 1001 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1002 Group C 1003 Mcb Control Light Points 1004 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Frls Pvc, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1005 Primary Point Controlled By One Mcb. 1006 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1007 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1008 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1009 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1010 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1011 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1012 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1013 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1014 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1015 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1016 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1017 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1018 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1019 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1020 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1021 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1022 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1023 Telephone Socket Outlet 1024 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1025 1 Or 2 Module ( 75Mmx75mm ) 1026 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1027 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1028 3 Pin , 5 / 6 Amps Socket Outlet 1029 5 / 6 Amps Switch 1030 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1031 25 Mm 1032 32 Mm 1033 Subhead -Ii - Fittings & Fixtures 1034 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1035 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1036 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1037 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1038 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1039 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1040 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1041 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1042 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1043 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1044 Subhead - Iii - Distribution Boards 1045 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1046 6 Way, Double Door 1047 8 Way, Double Door 1048 12 Way, Double Door 1049 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1050 4 Way ( 4 + 12 ) , Double Door 1051 6 Way ( 4 + 18 ) , Double Door 1052 8 Way ( 4 + 24 ) , Double Door 1053 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1054 12 Way ( 4 + 36 ) , Double Door 1055 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1056 Single Pole 1057 Single Pole Neutral 1058 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1059 40 A 1060 63 A 1061 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1062 40 A 1063 63 A 1064 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1065 25 A 1066 40 A 1067 63 A 1068 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1069 Subhead - Iv - Lightning Conductor 1070 Earthing With Cu. Earth Plate 600Mm X 600Mm X 3Mm Thick Includingaccesssories, And Providingmasonary Enclosurewith Cover Plate ( Ci Heavy Duty ) Having Locking Arrangement And Watering Pipe Of 2.7 Mtr Long Etc. With Charcoal Or Coke And Salt ) As Required. 1071 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1072 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1073 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1074 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1075 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1076 Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. 1077 Supply Of Lightnig Counter - Lcd Screen Shows The Number Of Lightning Strikes, Hour And Date Of Lightning Eventsbuttons Enable Time / Date Setting And Log Viewing. Replaceable Battery, Working Life Minimum Five Years, Meet The Requirements For Is / Iec 62305 And Iec 62561-2.Tested For Electrical , Mechanical And Chemical As Per Iec 62561. 1078 [ Type-Iii Residences G+2, 6Units. ] 1079 Earth Work 1080 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil Anddisposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 1081 All Kinds Of Soil 1082 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 1083 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming , Consolidating And Dressing Complete. 1084 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1085 Concrete Work 1086 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zoneiii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1087 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 1088 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 1089 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over75mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 1090 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 1091 Reinforced Cement Concrete 1092 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights 1093 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1094 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 1095 Lintels, Beams, Plinth Beams, Girders, Bressumers 1096 Columns, Pillars, Piers, Abutments, Posts And Struts. 1097 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 1098 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1099 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 1100 Pile Work 1101 Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) 400 Mm Dia Piles 1102 Vertical Load Testing Of Piles In Accordance With Is 2911 ( Part Iv ) Including Installation Of Loading Platform By Kentledge / Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Note: 1. Initial And Routine Load Test Shall Not Be Carried Out By Dynamic Method Of Testing.Note: 2. Testing Agency Shall Submit The Design Of Loading Platform For The Approval Of Engineer-In-Charge. 1103 Single Pile Upto 50 Tonne Safe Capacity 1104 Initial Test ( Test Load 2.5 Times The Safecapacity ) 1105 Routine Test ( Test Load 1.5 Times The Safecapacity ) 1106 Group Of Two Or More Piles Upto 50 Tonne Safe Capacity 1107 Initial Test ( Test Load 2.5 Times The Safecapacity ) 1108 Routine Test ( Test Load 1.5 Times The Safecapacity ) 1109 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 1110 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of Theminimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 1111 All Works Upto Plinth Level 1112 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1113 ( I ) R.C.C. Work In Footing 1114 ( Ii ) R.C.C. Work In Beam 1115 ( Iii ) R.C.C. Work In Columns 1116 All Works Above Plinth Level Upto Floor V Level 1117 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 1118 ( I ) R.C.C. Work In Lintel 1119 ( Ii ) R.C.C. Work In Beam 1120 ( Iii ) R.C.C. Work In Columns 1121 ( Iv ) R.C.C. Work In Slab 1122 Masonry Work 1123 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 1124 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 1125 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1126 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. ( The Payment Of Rccband And Reinforcement Shall Be Made For Seperately ) . 1127 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Foundation And Plinth In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1128 Cladding Work 1129 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 1130 Granite Stone Slab Colour Black, Cherry / Ruby Red 1131 Area Of Slab Upto 0.50 Sqm 1132 Area Of Slab Over 0.50 Sqm 1133 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 1134 Granite Work 1135 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 1136 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 1137 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1138 Wood And Pvc Work 1139 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is :2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Plyveneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Markedstainless Steel Butt Hinges With Necessary Screws 1140 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 1141 P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. 1142 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 1143 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 1144 300 Mm Weighing Not Less Than 200 Gms 1145 250 Mm Weighing Not Less Than 150 Gms 1146 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 1147 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Finecellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Selftapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As PermanufacturerS Specification And Direction Of Engineer-In-Charge. 1148 Providing And Fixing Pvc Rigid Foam Sheet 1 Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Based Adhesive. 1149 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size 1150 Kiln Seasoned And Chemically Treated Hollock Wood 1151 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 1152 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 1153 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 1154 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 1155 300 X 10Mm 1156 150 X 10Mm 1157 Providing And Fixing 6Mm Thick Both Sides Pre-Laminated Cement Bonded Wood Particle Board As Per Is : 15786:2008 Of Approved Brand And Shade With Suitable Full Threaded Steel Screws Etc. On The Backing Of Racks, Drawer, Cupboard, Kitchen Cabinet Under Kitchen Counter Etc. All Complete As Per Direction Of Engineer In-Charge. 1158 Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges ( Hydraulic Type ) Etc. Complete As Per Direction Of Engineer In-Charge. ( Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately ) 1159 Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Boxes, Shelves, Racks, Almirah, Cupboard And Drawer Etc. Including Necessary Nails, Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 1160 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 200 Mm For Cb 1161 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 100 Mm For Kitchen Cabinets 1162 Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges ( Hydraulic Type ) Of Approved Make / Brand Tocupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete Asperdirection Of Engineer-In-Charge 1163 Providing And Fixing Stainless Steel Soft Closing Heavy Type Telescopic Drawer Channels Of Approved Make 500 Mm Long With Screws Etc. Complete As Per Directions Of Engineer- In-Charge 1164 Ss Hanging Rod For Cb 1165 Providing And Fixing 25 Mm Dia. Ss Pipe Hanging Rods With Ss Brackets : 1166 Steel Work 1167 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 1168 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 1169 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 1170 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 1171 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1172 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 1173 Flooring 1174 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 1175 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 1176 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Includingpointing The Joints With White Cement And Matching Pigment Etc., Complete. 1177 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 1178 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 1179 Roofing 1180 Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete : 1181 With Residual Type Petroleum Bitumen Of Grade Vg -10 1182 Supply & Fixing Of Prepainted Coloured Trapezoidal Or Approved Profiled Sheeting 1000-1020 Mm Cover Width, 28-30 Mm High Crests With Subtle Square Fluting In The Five Pan At Nominal 190-255 Mm ( As Approved By Eic ) Centre-To-Centre Manufactured Out Of 0.50 Mm Tct Hi-Tensile Prepainted Zincalume / Galvalume Steel ( Az-150 Gsm. Aluminium –Zinc Alloy Metallic Coating Of Total Both Sides 550 Mpa Yield Stress As Per As-1397 ) . Colour / Exterior Coat Of Rmp 20 Micron Top Coat Applied Over 5 Micron Primer And A 5 Micron Polyester Back Coat Applied Over 5 Microns Primer Or Equivalent Coating / Painting. The Sheet Shall Have Wide Pans With Stiffening Ribs For Effective Water Shedding And Special Male / Female Ends With Full Return Legs On Side Laps For Purlin Support. The Male End Of The Sheet Shall Have Anti-Capillary Flute At Side Laps To Prevent Leakages. The Sheet Shall Be Fixed By Means Of Anti Corrosive Approved Make Rust Shield ( Epoxy Polymer ) Coated Self-Drilling Self Tapping Fasteners 12-14 X 55 Mm With Epdm Seals Through Crest For Roofing And 12-24 X 20 Mm Through Valley ( Pans ) For Wall Cladding. The Sheet Shall Be Supplied In Lengths Maximum Up To 6-12 Meter Long To Suit Site Dimensions. The Scope Includes All Sealing Of Joint, Curves, Edges Or Other Accessories With Silicon Sealant. 1183 Finishing 1184 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 1185 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 1186 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 1187 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 1188 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 1189 Steel Painting:Applying Priming Coat 1190 With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 1191 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 1192 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 1193 Two Or More Coats On New Work. 1194 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 1195 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1196 Water Proofing 1197 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 1198 Providing And Filling Of Cinder In Sunken Portions. 1199 Plumbing Internal Estimate ( Type-3 , 6 Unit ) ( G+2 ) 1200 Sub Head– I Sanitary Installation 1201 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 1202 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 1203 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 1204 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 1205 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 1206 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 1207 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 1208 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 1209 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 1210 Providing And Fixing Toilet Paper Holder : 1211 C.P. Brass 1212 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 1213 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 1214 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 1215 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 1216 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 1217 Kitchen Sink With Drain Board 1218 510X1040 Mm Bowl Depth 250Mm 1219 Kitchen Sink Without Drain Board 1220 610X460 Mm Bowl Depth 200 Mm 1221 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 1222 Size 450X300x150 Mm 1223 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 1224 Flexible Pipe 1225 40 Mm Dia 1226 Providing And Fixing Soil, Waste And Vent Pipes : 1227 100 Mm Dia 1228 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 1229 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1230 100 Mm 1231 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 1232 Providing And Fixing Plain Bend Of Required Degree. 1233 100 Mm 1234 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1235 Providing And Fixing Heel Rest Sanitary Bend 1236 100 Mm Dia 1237 Sand Cast Iron S&S As Per Is - 3989 1238 Providing And Fixing Double Equal Plain Junction Of Required Degree 1239 100X100x100x100 Mm 1240 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1241 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1242 100X100x100 Mm 1243 Sand Cast Iron S&S As Per Is: 3989 1244 Providing And Fixing Single Equal Plain Junction Of Required Degree 1245 100X100x100 Mm 1246 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1247 Providing And Fixing Terminal Guard: 1248 100 Mm 1249 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1250 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 1251 100 Mm 1252 S S 304 Grade Coupling With Epdm Rubber Gasket 1253 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 1254 100 Mm 1255 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 1256 100 Mm Diameter Pipe 1257 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 1258 100 Mm Diameter Pipe 1259 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1260 32 Mm Dia. Nominal Bore 1261 40 Mm Dia. Nominal Bore 1262 50 Mm Dia. Nominal Bore 1263 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 1264 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 1265 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 1266 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 1267 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 1268 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 1269 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 1270 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 1271 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 1272 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 1273 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 1274 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 1275 Coupler 1276 110 Mm 1277 Single Tee With Door 1278 110X110x110 Mm 1279 Bend 87.5° 1280 110 Mm 1281 Shoe ( Plain ) 1282 110 Mm Shoe 1283 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 1284 110 Mm 1285 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 1286 110 Mm Outer Dia 1287 50 Mm Outer Dia 1288 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 1289 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 1290 Sub Head– Ii Water Supply 1291 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1292 Internal Work – Exposed On Wall. 1293 20 Mm Nominal Outer Dia Pipes 1294 25 Mm Nominal Outer Dia Pipes 1295 32 Mm Nominal Outer Dia Pipes 1296 40 Mm Nominal Outer Dia Pipes 1297 50 Mm Nominal Outer Dia Pipes 1298 65 Mm Nominal Outer Dia Pipes 1299 80 Mm Nominal Outer Dia Pipes 1300 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 1301 Concealed Including Cutting Chases And Making Good The Wall Etc. 1302 15 Mm Nominal Outer Dia Pipes 1303 20 Mm Nominal Outer Dia Pipes 1304 25 Mm Nominal Outer Dia Pipes 1305 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1306 20 Mm Dia. Nominal Bore 1307 25 Mm Dia. Nominal Bore 1308 32 Mm Dia. Nominal Bore 1309 40 Mm Dia. Nominal Bore 1310 50 Mm Dia. Nominal Bore 1311 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 1312 25 Mm Nominal Bore 1313 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 1314 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 1315 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 1316 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 1317 15 Mm Nominal Bore 1318 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 1319 15 Mm Nominal Bore 1320 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 1321 15Mm Nominal Bore 1322 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 1323 45 Cm Length 1324 15 Mm Nominal Bore 1325 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 1326 150 Mm Diameter 1327 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 1328 ( A ) 15 Mm Nominal Dia 1329 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 1330 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 1331 Upto 50 Mm Dia. Nominal Bore 1332 Subhead– Iii Drainage 1333 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 1334 150 Mm Diameter 1335 200 Mm Diameter 1336 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 1337 180X150 Mm Size P Type 1338 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 1339 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1340 150 Mm Dia. R.C.C. Pipe 1341 250 Mm Dia. R.C.C. Pipe 1342 300 Mm Dia. R.C.C. Pipe 1343 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 1344 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 1345 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 1346 Extra Depth Formanhole 90X80 Cm 1347 With Fpsbricks Class Designation 7.5 1348 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 1349 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 1350 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1351 Electrical Works Type-3 ( G+2 ) Residence 1352 Sub Head - I: Circuit Cum Point Wiring 1353 Switch Control Light Points 1354 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1355 Group C 1356 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1357 Group C 1358 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1359 Group C 1360 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1361 Group C 1362 Mcb Control Light Points 1363 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1364 Primary Point Controlled By One Mcb. 1365 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1366 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1367 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1368 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1369 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1370 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1371 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1372 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1373 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1374 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1375 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1376 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1377 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1378 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1379 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1380 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1381 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1382 Telephone Socket Outlet 1383 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1384 1 Or 2 Module ( 75Mmx75mm ) 1385 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1386 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1387 3 Pin , 5 / 6 Amps Socket Outlet 1388 5 / 6 Amps Switch 1389 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1390 25 Mm 1391 32 Mm 1392 Subhead -Ii - Fittings & Fixtures 1393 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1394 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1395 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1396 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1397 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1398 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1399 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1400 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1401 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1402 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1403 Subhead - Iii - Distribution Boards 1404 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1405 6 Way, Double Door 1406 8 Way, Double Door 1407 12 Way, Double Door 1408 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1409 4 Way ( 4 + 12 ) , Double Door 1410 6 Way ( 4 + 18 ) , Double Door 1411 8 Way ( 4 + 24 ) , Double Door 1412 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1413 12 Way ( 4 + 36 ) , Double Door 1414 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1415 Single Pole 1416 Single Pole Neutral 1417 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1418 40 A 1419 63 A 1420 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1421 25 A 1422 40 A 1423 63 A 1424 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1425 25 A 1426 40 A 1427 63 A 1428 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1429 Sub Head-Iv , Lightning Conductor 1430 Lightning Conductor 1431 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1432 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 1433 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1434 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1435 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1436 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1437 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1438 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 1439 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 1440 [ Type-Ii Residences G+2, 7Units. ] 1441 Earth Work 1442 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 1443 All Kinds Of Soil 1444 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 1445 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming , Consolidating And Dressing Complete. 1446 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1447 Concrete Work 1448 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:5:10 ( 1 Cement : 5 Coarse Sand ( Zoneiii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1449 Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 1450 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 1451 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over75mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 1452 Brick Edging In Full Brick Width And Half Brick Depth Including Excavation Refilling And Disposal Of Surplus Earth Lead Upto 50 Metres. With Common Burnt Clayf.P.S. ( Non Modulur ) Bricks Of Class Designation 75 1453 Reinforced Cement Concrete 1454 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights 1455 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1456 Suspended Floors, Roofs, Landings, Balconies And Access Platform. 1457 Lintels, Beams, Plinth Beams, Girders, Bressumers 1458 Columns, Pillars, Piers, Abutments, Posts And Struts. 1459 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 1460 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1461 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 1462 Pile Work 1463 Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) 400 Mm Dia Piles 1464 Vertical Load Testing Of Piles In Accordance With Is 2911 ( Part Iv ) Including Installation Of Loading Platform By Kentledge / Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Note: 1. Initial And Routine Load Test Shall Not Be Carried Out By Dynamic Method Of Testing.Note: 2. Testing Agency Shall Submit The Design Of Loading Platform For The Approval Of Engineer-In-Charge. 1465 Group Of Two Or More Piles Upto 50 Tonne Safe Capacity 1466 Initial Test ( Test Load 2.5 Times The Safecapacity ) 1467 Routine Test ( Test Load 1.5 Times The Safecapacity ) 1468 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 1469 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength;Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of Theminimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 1470 All Works Upto Plinth Level 1471 Concrete Of M25 Grade With Minimum Cementcontent Of 330 Kg / Cum 1472 ( I ) R.C.C. Work In Footing 1473 ( Ii ) R.C.C. Work In Beam 1474 ( Iii ) R.C.C. Work In Columns 1475 All Works Above Plinth Level Upto Floor V Level 1476 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 1477 ( I ) R.C.C. Work In Lintel 1478 ( Ii ) R.C.C. Work In Beam 1479 ( Iii ) R.C.C. Work In Columns 1480 ( Iv ) R.C.C. Work In Slab 1481 Masonry Work 1482 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 1483 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 1484 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1485 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. ( The Payment Of Rccband And Reinforcement Shall Be Made For Seperately ) . 1486 Brick Work With Non Modular Fly Ash Bricks Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Foundation And Plinth In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1487 Poviding And Fixing Chicken Wire MeshOf 24 Gauge At Junctions Of Rcc & Brick Worksurfaces With Cement Mortar Including Necessary Nails Etc For Fixing All Height & Leveletc All Complete As Per Drawings And As Directed By Architect. ( 200 Mm Wide ) 1488 Cladding Work 1489 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 1490 Granite Stone Slab Colour Black, Cherry / Ruby Red 1491 Area Of Slab Upto 0.50 Sqm 1492 Area Of Slab Over 0.50 Sqm 1493 Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 1494 Granite Work 1495 Extra For Fixing Marble / Granite Stone Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive Including Cleaning Etc. Complete. 1496 Extra For Providing Opening Of Required Size & Shape For Wash Basins / Kitchen Sink In Kitchen Platform, Vanity Counters And Similar Location In Marble / Granite / Stone Work Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 1497 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1498 Wood And Pvc Work 1499 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is :2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Plyveneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Markedstainless Steel Butt Hinges With Necessary Screws 1500 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 1501 P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. 1502 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. 1503 Providing And Fixing Oxidised M.S. Casement Stays ( Straight Peg Type ) With Necessary Screws Etc. Complete. 1504 300 Mm Weighing Not Less Than 200 Gms 1505 250 Mm Weighing Not Less Than 150 Gms 1506 Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. Twin Rubber Stopper 1507 Providing And Fixing Factory Made Door Frame ( Single Rebate ) Made Out Of Single Piece Extruded Solid Pvc Foam Profile With Homogenous Fine Cellular Structure Having Smooth Outer Integral Skin Having 62 Mm Width & 32 Mm Thickness, Frame Will Be Mitred & Jointed With Self Driven Self Tapping Screws Of Size 38 Mm X 4 Mm & Pvc Solvent Cement, Including Fixing The Frame To Wall With Suitable Dia & Length Anchor Fastener As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 1508 Providing And Fixing Pvc Rigid Foam Sheet 1 Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Based Adhesive. 1509 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size 1510 Kiln Seasoned And Chemically Treated Hollock Wood 1511 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete.With 12 Mm Mild Steel U Beading 1512 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm. 1513 Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 1514 Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete. 1515 300 X 10Mm 1516 150 X 10Mm 1517 Providing And Fixing 6Mm Thick Both Sides Pre-Laminated Cement Bonded Wood Particle Board As Per Is : 15786:2008 Of Approved Brand And Shade With Suitable Full Threaded Steel Screws Etc. On The Backing Of Racks, Drawer, Cupboard, Kitchen Cabinet Under Kitchen Counter Etc. All Complete As Per Direction Of Engineer In-Charge. 1518 Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressedbwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges ( Hydraulic Type ) Etc. Complete As Per Direction Of Engineer In-Charge. ( Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately ) 1519 Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approvedbrand Boxes, Shelves, Racks, Almirah, Cupboard And Drawer Etc. Including Necessary Nails, Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 1520 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 200 Mm 1521 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Ofengineer-In-Charge. 100 Mm For Kitchen Cabinets 1522 Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges ( Hydraulic Type ) Of Approved Make / Brand Tocupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete Asperdirection Of Engineer-In-Charge 1523 Providing And Fixing Stainless Steel Soft Closing Heavy Type Telescopic Drawer Channels Of Approved Make 500 Mm Long With Screws Etc. Complete As Per Directions Of Engineer- In-Charge 1524 Ss Hanging Rod For Cb 1525 Providing And Fixing 25 Mm Dia. Ss Pipe Hanging Rods With Ss Brackets : 1526 Steel Work 1527 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 1528 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size 1529 Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular / L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer.Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 1530 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 1531 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 1532 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes. 1533 Flooring 1534 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 1535 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 1536 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Includingpointing The Joints With White Cement And Matching Pigment Etc., Complete. 1537 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 1538 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 1539 Roofing 1540 Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete : 1541 With Residual Type Petroleum Bitumen Of Grade Vg -10 1542 Supply & Fixing Of Prepainted Coloured Trapezoidal Or Approved Profiled Sheeting 1000-1020 Mm Cover Width, 28-30 Mm High Crests With Subtle Square Fluting In The Five Pan At Nominal 190-255 Mm ( As Approved By Eic ) Centre-To-Centre Manufactured Out Of 0.50 Mm Tct Hi-Tensile Prepainted Zincalume / Galvalume Steel ( Az-150 Gsm. Aluminium –Zinc Alloy Metallic Coating Of Total Both Sides 550 Mpa Yield Stress As Per As-1397 ) . Colour / Exterior Coat Of Rmp 20 Micron Top Coat Applied Over 5 Micron Primer And A 5 Micron Polyester Back Coat Applied Over 5 Microns Primer 1543 Or Equivalent Coating / Painting. The Sheet Shall Have Wide Pans With Stiffening Ribs For Effective Water Shedding And Special Male / Female Ends With Full Return Legs On Side Laps For Purlin Support. The Male End Of The Sheet Shall Have Anti-Capillary Flute At Side Laps To Prevent Leakages. The Sheet Shall Be Fixed By Means Of Anti Corrosive Approved Make Rust Shield ( Epoxy Polymer ) Coated Self-Drilling Self Tapping Fasteners 12-14 X 55 Mm With Epdm Seals Through Crest For Roofing And 12-24 X 20 Mm Through Valley ( Pans ) For Wall Cladding. The Sheet Shall Be Supplied In Lengths Maximum Up To 6-12 Meter Long To Suit Site Dimensions. The Scope Includes All Sealing Of Joint, Curves, Edges Or Other Accessories With Silicon Sealant. 1544 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) 1545 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. 1:6 ( 1 Cement: 6 Coarse Sand ) 1546 6 Mm Cement Plaster On Celling ( A ) 1:3 ( 1 Cement:3 Fine Sand ) 1547 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer. 1548 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade. New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . 1549 Steel Painting:Applying Priming Coat 1550 With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 1551 With Ready Mixed Red Oxide Zink Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 1552 Painting Withsynthetic Enamel Paint Of Approvedbrandand Manufactureto Give An Even Shade: 1553 Two Or More Coats On New Work. 1554 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 1555 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1556 Water Proofing 1557 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 1558 Providing And Filling Of Cinder In Sunken Portions. 1559 Plumbing Internal Estimate ( Type-2 , 7 Unit ) ( G+3 ) 1560 Sub Head– I Sanitary Installation 1561 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:. 1562 White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. 1563 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 1564 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 1565 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 1566 Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification Anddirection Of Engineer-In-Charge. 1567 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: 1568 White Vitreous China Wash Basin Size 550X400 Mmwith A Pair Of 15 Mm C.P. Brass Pillar Taps 1569 Providing And Fixingwhite Vitreous China Wash Basin Under Counter Basin, With C.I. Concealed Type Brackets Fixed To Walls With Gi Rag Bolts Or Approved Fasteners Etc., Including 32 Mm Cp Brass Waste Coupling, Includingpainting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required All Complete ( Granite Counter Top Will Be Measured And Paid Separately Under Relevent Item ) : As Per Approved Make And Decision Of Engineer-In-Charge 1570 Providing And Fixing Toilet Paper Holder : 1571 C.P. Brass 1572 Providingandfixingcpbrassauto Closing System Basin Pillartap / Hand Washofjaquar Prs - 001 Or Equivalentasapprovedbyengineer-In Charge 1573 Providingandfixingcpbrasssingle Lever Basin Mixerwithout Popowith 450Mm Long Braided Hose ( Connection Pipe ) Basin Pillartapofjaquar Lyr-38001B Or Equivalentasapprovedbyengineer-In Charge. 1574 Providing And Fixing 32Mm C.P Brass Bottle Trap Of Approved Quality & Make As Per The Direction Of Engineer-In-Incharge. 1575 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 1576 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Paintingoffittingsandbrackets, Cuttingandmakinggoodthewalls Wherever Required : 1577 Kitchen Sink With Drain Board 1578 510X1040 Mm Bowl Depth 250Mm 1579 Kitchen Sink Without Drain Board 1580 610X460 Mm Bowl Depth 200 Mm 1581 Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : 1582 Size 450X300x150 Mm 1583 Providing And Fixing P.V.C. Waste Pipe For Sinkor Wash Basin Including P.V.C. Waste Fittings Complete. 1584 Flexible Pipe 1585 40 Mm Dia 1586 Providing And Fixing Soil, Waste And Vent Pipes : 1587 100 Mm Dia 1588 Hubless Centrifugally Cast ( Spun ) Iron Pipes Epoxy Coated Inside & Outside Is:15905 1589 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1590 100 Mm 1591 Hubless Centrifugally Cast ( Spun ) Iron Epoxy Coated Inside & Outside I.S. 15905 1592 Providing And Fixing Plain Bend Of Required Degree. 1593 100 Mm 1594 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1595 Providing And Fixing Heel Rest Sanitary Bend 1596 100 Mm Dia 1597 Sand Cast Iron S&S As Per Is - 3989 1598 Providing And Fixing Double Equal Plain Junction Of Required Degree 1599 100X100x100x100 Mm 1600 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1601 Providing And Fixing Single Equal Plain Junction Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete. 1602 100X100x100 Mm 1603 Sand Cast Iron S&S As Per Is: 3989 1604 Providing And Fixing Single Equal Plain Junction Of Required Degree 1605 100X100x100 Mm 1606 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1607 Providing And Fixing Terminal Guard: 1608 100 Mm 1609 Hubless Centrifugally Cast ( Spun ) Iron Pipe Epoxy Inside & Outsideis: 15905 1610 Providingand Fixing Shielded Coupling For Hubless Centrifugally Cast Iron Pipes 1611 100 Mm 1612 S S 304 Grade Coupling With Epdm Rubber Gasket 1613 Providing And Fixing M.S. Stays And Clamps For Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Pipes Of Diameter : 1614 100 Mm 1615 Painting Sand Cast Iron / Centrifugally Cast ( Spun ) Iron Soil, Waste Vent Pipes And Fittings With Two Coats Of Synthetic Enamel Paint Of Any Colour Such As Chocolate Grey, Or Buff Etc. Over A Coat Of Primer ( Of Approved Quality ) For New Work : 1616 100 Mm Diameter Pipe 1617 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron / Cast Iron ( Spun ) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10cm Of 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Cost Of Cutting Holes And Making Good The Walls Etc. : 1618 100 Mm Diameter Pipe 1619 Providing And Fixing G.I. Soil / Waste Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1620 32 Mm Dia. Nominal Bore 1621 40 Mm Dia. Nominal Bore 1622 50 Mm Dia. Nominal Bore 1623 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 1624 100 Mm Inlet And 100 Mm Outlet 1625 Hubless Centrifugally Cast ( Spun ) Iron Epoxycoated Inside & Outside As Per Is:15905 1626 Cutting Holes Up To 15 X 15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete So As To Make It Leak Proof. 1627 Providing & Fixing In Position Gi 100X50 Elbowfloor Drainincluding Cost Of Cutting And Making Good The Walls And Floors Whereverrequired. 1628 Providingandfixing125mmdias / S Grating ( Withorwithouthole ) For Floor Or Nahani Trap. 1629 Providing And Fixing Soap Dish Holderfrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1131N & Equivalent 1630 Providing And Fixing Soap Dispenser With Glass Bottlefrom Wall Of Standard Shape Withfittings Of Approved Quality With All Complete. Make Jaquar - Acn-1135N & Equivalent 1631 Providing & Fixing600 Mm Towel Rail Long Stanless Steel From Wall Face With Concealedfittings Arrangement Of Approved Quality With All Complete. Make Jaquar - Can-1111Sm 1632 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. 1633 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 1634 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. 1635 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 1636 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 1637 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 1638 Coupler 1639 110 Mm 1640 Single Tee With Door 1641 110X110x110 Mm 1642 Bend 87.5° 1643 110 Mm 1644 Shoe ( Plain ) 1645 110 Mm Shoe 1646 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 1647 110 Mm 1648 Supplying And Fixingofhdpe Pipe ( Pe Grade 63 - Pn-8 ) Confirming To Is 14333-1996Chemical Waste Pipes Jointed With Rubber Ring With Good Quality Lubricantwithfittingsinclussive Of Allnecessaryspecialslike Bends, Tees, Offsets, Junctions Etc Laid Under Floor / Under Ceiling / On Walls With Suitable Clamps And Specialscuring, Necessary Chasing, Jointing And Restoring To Original Conditions, Testing Etc. Including All Other Incidental Chargesetc.Complete For Successful Completion Of Work As Per Specifications, And Asdirected By Engineer -In- Charge. 1649 110 Mm Outer Dia 1650 50 Mm Outer Dia 1651 Providing & Fixing In Position Upvc POr S Trap Of Self Cleaning Design Offollowingsizesfor The Embedded Areasmaking Proper Connection Withchemical Sealent Joint , Cutting Chase / Hole In Floors / Slabs And Bringing The Same In Proper Condition In Cement Concrete 1:2:4 Mix Complete As Required. Including Cost Of Cutting And Making Good The Walls And Floors Wherever Required. 1652 Providing & Fixingwater Cooler Wth Stainless Steel Having Storage Capacity Of 80 Liter & Cooling Capacity 60 Liter / Hour With Reverse Osmosis System & Ultra Voilet Membrane Tds Reduction 90% Having Automatic Back Wash System With Filteration Unit & All Other Required Accessories Complete In All Respect As Per Direction Of The Engineer In Charge . 1653 Sub Head– Ii Water Supply 1654 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. 1655 Internal Work – Exposed On Wall. 1656 20 Mm Nominal Outer Dia Pipes 1657 25 Mm Nominal Outer Dia Pipes 1658 32 Mm Nominal Outer Dia Pipes 1659 40 Mm Nominal Outer Dia Pipes 1660 50 Mm Nominal Outer Dia Pipes 1661 65 Mm Nominal Outer Dia Pipes 1662 80 Mm Nominal Outer Dia Pipes 1663 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. 1664 Concealed Including Cutting Chases And Making Good The Wall Etc. 1665 15 Mm Nominal Outer Dia Pipes 1666 20 Mm Nominal Outer Dia Pipes 1667 25 Mm Nominal Outer Dia Pipes 1668 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1669 20 Mm Dia. Nominal Bore 1670 25 Mm Dia. Nominal Bore 1671 32 Mm Dia. Nominal Bore 1672 40 Mm Dia. Nominal Bore 1673 50 Mm Dia. Nominal Bore 1674 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 1675 25 Mm Nominal Bore 1676 Providing And Fixing Hand Held Ablution Fitting ( Health Faucet ) With 1.2 Meter Long Flexible Tube And Wall Hook, All Complete Approved Engineer-In-Charge 1677 Supply And Fixing Of 15Mm Cp Brass 2 -Way Bib Cock With Wall Flange And Suitable Length Cp Brass Extension Pipe All Of Approved Engineer-In-Charge 1678 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 1679 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 1680 15 Mm Nominal Bore 1681 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. 1682 15 Mm Nominal Bore 1683 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 1684 15Mm Nominal Bore 1685 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 1686 45 Cm Length 1687 15 Mm Nominal Bore 1688 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 1689 150 Mm Diameter 1690 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 1691 ( A ) 15 Mm Nominal Dia 1692 Providing , Fixing, Testing And Commissioning Of Cp Brass 150 Mmx 150 Mmshower Head With Wall Flange With All Accessories As Required Andmaking Good The Walls Wherever Required. ( Make-Jaquar -Model No- Ohs-35495 Or Equivalent. ) 1693 Supply , Erection , Testing & Commissioning Of Automatic Water Level Control Panel & Related Accessories For Pumping Automation With Consisting Of Automatic Water Level Controller , Level Sensor Withstainless Steel Probe, Motorized Butterfly Valve, Motorized Valve Controller With Complete In All Respect. 1694 Upto 50 Mm Dia. Nominal Bore 1695 Subhead– Iii Drainage 1696 Supply And Fixing Hdpe Double Wall Corrugated ( Dwc ) I.S 16098 ( Part - 2 ) 3013 For Soil / Waste Pipe Under Ground Drainage System Withjointed With Rubber Ring With Good Quality Lubricant For Fittings, Inclusive Of All Necessary Specials Like Bends, Tees, Offsets, Junctions, Re Excavtion And Refillig Etc Complete. 1697 150 Mm Diameter 1698 200 Mm Diameter 1699 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brickmasonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Lessthan 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : 1700 180X150 Mm Size P Type 1701 With Fly Ash Bricks ( Non Modular ) Bricks Of Class Designation 7.5 1702 Providingandlayingnon-Pressurenp2class ( Lightduty ) R.C.C.Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1703 150 Mm Dia. R.C.C. Pipe 1704 250 Mm Dia. R.C.C. Pipe 1705 300 Mm Dia. R.C.C. Pipe 1706 Constructing Brick Masonry Manholein Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) With Rcc Top Slab With 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Stone Aggregate 40 Mm Nominal Size ) Inside Plastering12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement, Foundation Cocreate 1:3:6 Mix ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Norminal Size ) , And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Norminal Size ) Finished With A Floating Coat Of Neat Cementcomplete As Per Standard Design . 1707 Inside Size 90X80 Cms And 45 Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions Total Weight Of Cover & Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg & Weight Of Frame 15 Kg ) 1708 With Common Brunt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 1709 Extra Depth Formanhole 90X80 Cm 1710 With Fpsbricks Class Designation 7.5 1711 Providing Orange Colour Safety Foot Rest Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is : 10910, On 12 Mm Dia Steel Bar Conforming To Is:1786, Having Minimum Cross Section As 23 Mmx25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Tread On Top Surface By Ribbing Or Chequeringesides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Pecifications And Having Manufacture’S Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 1712 Constructing Brick Masonry Road Gully Chamber 50X45x60 Cm With Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : 1713 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1714 Electrical Works Type-2 ( G+3 ) Residence 1715 Sub Head - I: Circuit Cum Point Wiring 1716 Switch Control Light Points 1717 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1718 Group C 1719 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1720 Group C 1721 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1722 Group C 1723 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Withoutindependent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Switch Control Secondary Points ) 1724 Group C 1725 Mcb Control Light Points 1726 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Switch Control Primary Points ) 1727 Primary Point Controlled By One Mcb. 1728 Same As Item Above But Secondary Point. I.E. Points To Be Looped With Primary Pointwith 2.5 Sqmm Wire And Point Wiring 1729 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 1730 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 1731 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 1732 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 1733 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 1734 2 X 10 Sq. Mm + 1 X 10 Sq.Mm Earth Wire 1735 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1736 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 1737 Supplying And Fixingsuitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing3 Pin 5 / 6 Amp Modular Socket Outlet And 5 / 6 A Modular Switch, Connection Etc. As Required. 1738 Supply And Wiringfor 250 Volts Singlephase And Neutral 2 Nos 6 Amps Socket Outlate With Control By 1 No Switched With 2.5 Sq.Mm Pvcinsulatedcopper Conductor1100 Volts Grade Stranded Flexible Frls Wires Inconcealed Or Surface Mounted 25 Mm Dia 2Mm Thickpvc Conduit Including Providing And Fixing Of 6 Amps 3 Pin Switch Socket Outlet Of Aprpoved Make And Design In 2 Mm Thick Gi Box With Grid Plate And Earthingofthird Pin Of The Socket With2.5Sq. Mm Pvc Insulated Copper Conductor Strandedflexiblefrlswire. ( Maximum Four No. Of Switches Socket Shall Be Connected On Onecircuit ) 1739 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 1740 Supplying And Fixing 63 A, 415 V, Tpn Industrial Type Socketoutlet, With 4 Pole And Earth, Metal Enclosed Plug Topalongwith 63 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1741 Supplying And Fixing 80 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 80 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. 1742 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 1743 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25 Amp Modular Socket Outlet And 25 Amps Modular Sp Mcb, “C” Curve Including Connection, Painting Etc. As Required. ( AcS & Gysers ) 1744 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 1745 Telephone Socket Outlet 1746 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1747 1 Or 2 Module ( 75Mmx75mm ) 1748 6 Module ( 78Mm X 205 Mm X 50 Mm ) 1749 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1750 3 Pin , 5 / 6 Amps Socket Outlet 1751 5 / 6 Amps Switch 1752 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 1753 25 Mm 1754 32 Mm 1755 Subhead -Ii - Fittings & Fixtures 1756 Supply, Installation, Testing And Commissioning Of 10 W Bulk Head Light. 1757 Supply, Installation, Testing And Commissioning Of 5W Mirror Light. 1758 Supply, Installation, Testing And Commissioning Of 18W Surface / Recessed Mounted Led Circular Downlighter. 1759 Supply, Installation, Testing And Commissioning Of 18 / 20W Wall / Surface Mouted 4 Ft. Led 1760 Supply, Installation, Testing And Commissioning Of 15Wsurface Mountedled Square Downlighter. 1761 Supply, Installation, Testing And Commissioning Of150 W Chandelier 1762 Supply, Installation, Testing And Commissioning Of 12 / 9Wrecessed Mountedled Circular Downlighter. 1763 Supply, Installation, Testing And Commissioning Of9w ( Nominal ) Wall Bracket Light 1764 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1765 Supplyinstallation, Testing And Commissioning Of 250 Mm Dia Domestic Exhaust Fan 1766 Subhead - Iii - Distribution Boards 1767 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1768 6 Way, Double Door 1769 8 Way, Double Door 1770 12 Way, Double Door 1771 Supplying And Fixing Following Way, Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 1772 4 Way ( 4 + 12 ) , Double Door 1773 6 Way ( 4 + 18 ) , Double Door 1774 8 Way ( 4 + 24 ) , Double Door 1775 Supplyingand Fixingoffollowingwayssurface / Recessmounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note :Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 1776 12 Way ( 4 + 36 ) , Double Door 1777 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1778 Single Pole 1779 Single Pole Neutral 1780 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1781 40 A 1782 63 A 1783 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1784 25 A 1785 40 A 1786 63 A 1787 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 1788 25 A 1789 40 A 1790 63 A 1791 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 1792 Sub Head-Iv , Lightning Conductor 1793 Lightning Conductor 1794 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 1795 Fixing Of Lightning Conductor Finial ( Single Prong ) With Base Plate Including Holes Etc. Complete As Required. 1796 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required. 1797 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 1798 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1799 Fixing Of Copper / G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 1800 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. 1801 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. Details Of Cost For One Set 1802 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 1803 Earth Filling 1804 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1805 Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks Etc., Lead Upto 50 M And Lift Upto 1.5 M : 1806 Footpath 2.00 Mt. Wide 1807 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge 1808 All Kinds Of Soil 1809 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level. 1810 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1811 Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved S;Ze, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 1812 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Ncluding Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ) . ( Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge ) . 1813 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : 1814 Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture 1815 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1816 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Ofoundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 1817 Deduct Pcc 1818 Kurb Stone 1819 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 1820 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 1821 Bituminus Road For 3.5 Mtr Wide & 10.0 Mtr Long Road 1822 Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Of Surplus Earthwith Lead Upto 50 Metres. 1823 Supplying And Stacking At Site.90 Mm To 45 Mm Size Stone Aggregate 1824 Supplying And Stacking At Site63 Mm To 45 Mm Size Stone Aggregate 1825 Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Pecifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road / Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Densi 1826 Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Pecifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road / Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Densi 1827 Supplying And Stacking At Sitestone Screening 13.2 Mm Nominal Size ( Type A ) 1828 Supplying And Stacking At Sitestone Screening 11.2 Mm Nominal Size ( Type B ) 1829 Supplying And Stacking At Sitered Bajri 1830 Supplying And Stacking At Sitemoorum 1831 2.5 Cm Premix Carpet Surfacing With 2.25 Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippingsof 13.2 Mm And 11.2 Mm Size Respectively, Including A Tack Coat With Hot Straight Run Bitumen, Including Consolidation With Road Rollerof 6 To 9 Tonne Capacity Etc. Complete ( Tack Coat To Be Paid For Separately ) .With Paving Asphalt Grade Vg - 10 Heated And Then Mixed With Solvent At The Rate Of 70 Grams Per Kg Of Asphalt 1832 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Ncluding Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ) . ( Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge ) . 1833 Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications :On W.B.M. @ 0.75 Kg / Sqm 1834 Providing And Laying Seal Coat Of Premixed Fine Aggregate ( Passing 2.36 Mm And Retained On 180 Micron Sieve ) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg - 10 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface, Including Rolling And Finishing With Road Roller All Complete 1835 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 1836 Sub Head ( I ) :- External Water Supply Pipes And Fittings 1837 All Kinds Of Soil 1838 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. 1839 External Work 1840 20 Mm Dia Nominal Bore 1841 25 Mm Dia Nominal Bore 1842 32 Mm Dia Nominal Bore 1843 40 Mm Dia Nominal Bore 1844 50 Mm Dia Nominal Bore 1845 65 Mm Dia Nominal Bore 1846 Painting G.I. Pipes And Fittings With Two Coats Of Anti-Corrosive Bitumastic Paint Of Approved Quality : 1847 20 Mm Diameter Pipe 1848 25 Mm Diameter Pipe 1849 32 Mm Diameter Pipe 1850 40 Mm Diameter Pipe 1851 50 Mm Diameter Pipe 1852 65 Mm Diameter Pipe 1853 Providing And Filling Sand Of Grading Zone V Or Coarser Grade Alround The Gi Pipes In External Work. 1854 20Mm Dia Nominal Bore 1855 25Mm Dia Nominal Bore 1856 32Mm Dia Nominal Bore 1857 40Mm Dia Nominal Bore 1858 50 Mm Diameter Pipe 1859 65 Mm Diameter Pipe 1860 Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) : 1861 50 Mm Dia 1862 80 Mm Dia 1863 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 1864 20 Mm Nominal Bore 1865 25 Mm Nominal Bore 1866 32 Mm Nominal Bore 1867 40 Mm Nominal Bore 1868 50 Mm Nominal Bore 1869 65 Mm Nominal Bore 1870 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 1871 Providing And Fixing G.I. Union In Gi Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 1872 25 Mm Nominal Bore 1873 32 Mm Nominal Bore 1874 40 Mm Nominal Bore 1875 50 Mm Nominal Bore 1876 65 Mm Nominal Bore 1877 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 1878 Ld- 2.5 1879 Rectangular Shape 600*450 Mm Internal Dimensions 1880 Constructing Masonry Gate Valve Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 1881 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1882 Constructing Masonry Chamber 60X45x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Water Meter Complete With C.I. Double Flap Surface Box 400X200x200 Mm ( Inside ) With Locking Arrangement And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 1883 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 1884 Surface Drain ( 250X150 Mm ) 1885 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 1886 All Kinds Of Soil 1887 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 1888 Qty. = 25% Of Them No 1 1889 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shttering - All Work Up To Plinth Level 1890 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 1891 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 1892 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 1893 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : 1894 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 1895 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In : 1896 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 1897 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix : 1898 1:4 ( 1 Cement: 4 Fine Sand ) 1899 Construction Of 300 Mm Wider.C.C. Drains 1900 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge.All Kinds Of Soil 1901 Lvl 0.00 To 1.5 1902 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 1903 @ 30% Of Item No. 1 1904 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1905 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Settingof Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 1906 Footing 1907 Wall 1908 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 1909 Footing 1910 Wall 1911 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 1912 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 1913 Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 1914 Sub Head ( I ) :- External Sewerage System 1915 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. Anddisposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : 1916 All Kinds Of Soil 1917 Pipes, Cables Etc. Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia 1918 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm 1919 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1920 150 Mm Dia. R.C.C. Pipe 1921 450 Mm Dia. R.C.C. Pipe 1922 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) 1923 450 Mm Diameter S.W.Pipe ( 9X0.65X0.10=0.59 ) 1924 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 1925 150 Mm Diameter S.W.Pipe ( 391X0.35X0.10=13.69 ) 1926 Constructing Brick Masonry Manholein Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) With Rcc Top Slab With 1 : 2 : 4 Mix ( 1 Cement : 2 Coarse Sand : 4Gradestone Aggregate 20Mm Nominal Size ) ; Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Gradedstoneaggregate40 Mm Nominalsize ) Insideplastering 12 Mm Thickwith Cementmortar 1:3 ( 1Cement 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement And Makingchannels Incementconcrete 1:2:4 ( 1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finishd With A Floating Coat Ofneatcement Completeasper Standard Design 1927 Inside Size 90 X 80 Cm & 45 Cmdeep Including Ci Cover With Frame ( Light Duty ) 455 X 610Mm Internal Dimensions, Total Weight Of Cover & Frame To Be Not Lessthan 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) 1928 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Classic Designation 7.5 1929 Extra For Depth For Manholes: 1930 Size 90 X 80 Cm 1931 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1932 Constructing Brick Masonry Circular Type Manhole 0.91 M Internal Dia At Bottom And 0.56M Dia At Top With Fps Bricksclass Designation 75In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Inside Cement Plaster 12Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With A Floating Coat Of Of Neat Cement, Foundation Concrete 1:3:6 Mix ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 40Mm Nominal Size ) And Making Necessary Channel In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. 1933 0.91M Deep With Sfrc Cover And Frame ( Heavy Duty Hd-20 Grade Designation ) 560Mm Internal Diameter Conforming To I.S:12592, Total Weight Of Cover And Frame To Be Not Less Than 182Kg. Fixed In Cement Concrete 1:2:4 Mix ( 1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size ) Including Centering, Shuttering All Complete. ( Excavation Foot Rests And 12Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately ) 1934 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 1935 Extra Depth For Circuler Type Manholes 0.91 M Internal Dia ( At Bottom ) Beyond 0.91M To 1.67 M . 1936 With Common Burnt Clay F.P.S. ( Non Module ) Brick Of Class Designation 7.5 1937 Providing And Fixing Square Mouths. W. Gully Trapclass Sp-1 Complete With C.I. Gratingbrickmasonry Chamber With Water Tight Ci Cover With Frame Of 300 X 300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 1938 180 X 150 Mm. Size P Type 1939 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 1940 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20x10 Cm Cement Concrete Blocks 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) As Per Standard Design : 1941 With 20 Mm Diameter Round Bar 1942 Hume Pipe 1943 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : 1944 All Kinds Of Soil 1945 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm 1946 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 1947 450 Mm Dia. R.C.C. Pipe 1948 Providingandlayingcementconcrete 1 : 5 : 10 ( 1 Cement : 5 Coarse Sand : 10 Gradded Stoneaggregate40 Mm Nominal Size ) Alround S.W. Pipesincludingbed Concrete As Per Standard Design. 1949 450 Mm Diameter S.W.Pipe 1950 Supplying, Installing, Testing & Commissioning Of Following Type Compartmentalised Wall Mounted / Floor Mounted Cubicle Board Made From 2Mm Thick Crca Sheet Dust & Vermin Proof Duly Phosphatized & Powder Coated Inclusive Of Suitable Size 4 Strip Al. Busbar Complete With Interconnection Providing Lugs, Inter-Earthing, Painting Etc. I / C Providing & Fixing Below Noted Accessories: 1951 Receiving, Unloading, Storing, Handling, Installation, Testing And Commissioning Of Following Mv Switchboards Complete As Required And As Per Site Condition And Dimension Of All Panels Shall Be Carried Out As Per The Attachad Sld 1952 Feeder Pillar 1953 Design, Manufacturing, Supplying, Fixing In Position, Testing And Commissioning Of The Following Front Operated Front Access 2Mm Thick Crca Steel Enclosure Free Standing, Water, Dust And Vermin Proof Outdoor Type Feeder Pillars With Ip-55 Protection Hinged And Lockable Doors Complete With Interconnections Copper Crimping Lugs, Brass Glands Bonding To Earth And Painting, Suitable For Use At 415 Volts, 3 Phase 4 Wire 50 Hz System . The Panels Fault Withstanding Capacity Shall Be Of 25 Mva At 415 Volts. All Live Accessories Part Shall Be Shrouded And All Equipment Shall Be Finger Touch Proof. The Bus Bars Shall Be Of Colure Coded With Heat Shrinkable Pvc Insulated Sleeves. 1954 Feeder Pillar-2 For Boys Dormitory, Type-Ii, Vice Principal & Guest House, Type-Iii 1955 Incomer 1956 1 No. 250A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 1957 1 No. Digital Multifunction Meter ( V+A+Hz ) With A Set Of Cast Resin Cts 250 / 5A. 1958 1 Set Of Phase Indicating Lamp With Mcb 1959 Bus Bars-I : 1960 300A Tpn Bus Bars Of Aluminium Alloy. 1961 For Emergency Supply 1962 1 No. 63A, 415V, Ics=25Ka, 4P Mccb With Thermal Magnetic Trip Unit. 1963 1 Set Of On Indicating Lamp With Mcb 1964 Bus Bars-Ii : 1965 100A Tpn Bus Bars Of Aluminium Alloy. 1966 Out Going Bus-I : 1967 8 Nos. 63A 415V, 4P Mccb Of 15Ka . 1968 1 No. 100A 415V, 4P Mccb Of 15Ka . 1969 1 No. Mcb Space. 1970 Out Going Bus-Ii : 1971 2 Nos. 63A 415V, 4P Mcb Of 10Ka . 1972 1 No. 40A 415V, 4P Mcb Of 10Ka With 40A 4P Contactor & Timer Switch . 1973 2 Nos. 25A 415V, 4P Mcb Of 10Ka . 1974 1 No. Mcb Space. 1975 Meter Boards 1976 Supply, Installation, Testing And Commissioning Of M.V. Cubical Type Totally Enclosed Dust, Dump And Vermin Proof Meter Bords Complete With Bus Bars, Mv Danger Notice Plate, On Surface Isi Marked Electronic Kwh Meter, Indication Lamps, CtS, Interconnection With Suitable Capacity Aluminium Strips / Rods, Door Covers, Seperate Compartment For Each Meter, Glass Inspection Window, Connection Of Incoming And Outgoing Cables With Thimbles, Powder Coated Having Following Incoming And Outgoingmcbs Mccbs And Kwh Meters Complete As Required. 1977 Panel - Boys Dormitory & Girls Dormitory 1978 1 No. 100, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 1979 Bus Bars: 1980 125A Tpn Bus Bars Of Aluminium Alloy. 1981 Out Going: 1982 4 Nos. 40A Dp Mcb Of 10Ka With Space For Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 1983 1 No. 40A Dp Mcb Of 10Ka. 1984 Meter Boards - Type-Ii ( G ) 1985 1 No. 40A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 1986 Out Going: 1987 Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 1988 1 No. 40A Dp Mcb Of 10Ka. 1989 Meter Boards - Vice Principal 1990 1 No. 63A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 1991 Out Going: 1992 Electronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 1993 Meter Boards - Type-Iii Residence ( G+2 ) 1994 1 No. 100A, 415V, Ics= 16Ka, 4P Mccb With O / C, S / C Protection & On Indication Lamp. 1995 Bus Bars: 1996 125A Tpn Bus Bars Of Aluminium Alloy. 1997 Out Going: 1998 6 Nos. 40A Dp Mcb Of 10Ka Withelectronic Direct Kwh Energy Meter Complete With All Necessary Wiring As Per The Meter Vendor Requirement. 1999 Subhead - Ii - Earthing 2000 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 2001 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonary Enclosure With Cover Plate Having Locking Arrangement And Watering Watering Pipe 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 2002 Earthing With Cu. Earth Plate 600Mm X 600Mm X 3Mm Thick Includingaccesssories, And Providingmasonary Enclosurewith Cover Plate ( Ci Heavy Duty ) Having Locking Arrangement And Watering Pipe Pipe Of 2.7 Mtr Long Etc. With Charcoal Or Coke And Salt ) As Required. 2003 Supplying And Laying 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode, Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Refilling Etc. As Required. 2004 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 2 Nos Used For 50 X 5 For The Neutral Earthing Of Euipments ) 2005 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 2006 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Etc. As Required. 2007 Subhead - Iii - Supplying & Laying Of Cable 2008 L.T. Cables 2009 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers, Etc. Conforming To Is 14930. Part Ii Complete With Fitting And Cutting, Jointing Etc. Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushing And Protective Covering Etc., Complete As Required. 2010 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 2011 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) 2012 120 Mm Dia ( Od-120 Mm & Id-175 Mm Nominal ) 2013 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing, Etc. In The Existing Trench, Complete As Required. 2014 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) 2015 120 Mm Dia ( Od-120 Mm & Id-175 Mm Nominal ) 2016 Laying Of One Number Pvc Insulated & Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 2017 Upto 35 Sq.Mm 2018 Above 35 Sq. Mm And Upto 95 Sq. Mm 2019 Above 95 Sq.Mm And Upto 185 Sq.Mm 2020 Supply Of Following Sizes Of Xlpe Insulatedaluminum Conductor Strip / Wire Armoured, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is-7098 Code And Technical Specifications. 2021 6 Sq. Mm 4 Core 2022 2 X 10 Sq. Mm ( 28Mm 2023 3½ X 25 Sq. Mm ( 28Mm ) 2024 3½ X 35 Sq. Mm ( 32Mm ) 2025 3½ X 50 Sq. Mm ( 35Mm ) 2026 3½ X 150 Sq. Mm ( 50Mm ) 2027 3½ X 185 Sq. Mm ( 57Mm ) 2028 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Gradeas Required. 2029 4 X 6 Sq. Mm ( 28Mm 2030 4 X 16 Sq. Mm ( 28Mm 2031 3½ X 25 Sq. Mm ( 28Mm ) 2032 3½ X 35 Sq. Mm ( 32Mm ) 2033 3½ X 50 Sq. Mm ( 35Mm ) 2034 3½ X 150 Sq. Mm ( 50Mm ) 2035 3½ X 185 Sq. Mm ( 57Mm ) 2036 Providing, Laying And Fixing Following Dia Rcc Pipe Np2 Class ( Light Duty ) In Ground Complete With Rcc Collars, Jointing With Cement Mortar 1:2 ( 1 Cement : 2 Fine Sand ) Including Trenching ( 75 Cm Deep ) And Refilling Etc As Required. 2037 150 Mm Dia 2038 250 Mm Dia 2039 Sub Head -Iv :External Light 2040 Erection Of Metallic Pole Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 2041 Above 6.5 Metre And Upto 8.0 Metre 2042 Supplying, Installation, Testing And Commissioning Of 50W Led Street Lightip66 Led With High Performance Having System Lumen Output Of Minimum 9900 Lumens, Contemporary Designed Housing Made Of Die-Cast Aluminium, With Street Optic Lens For Uniform Light Distribution. Pf Better Than 0.9, Cri Better Than 70 Complete With All Accessories. Wipro Cat No.: Lr 02-102-Xxx-57-G2 Street Light 2043 Supplying, Installation, Testing And Commissioning Of 50W Ledsolar Street Light On 6 Meter Gi Octagonal Pole Having Compact, Aesthetic, Eco Friendly & Modern Integrated Solar Street Light In Extruted Aluminum Construction With High Efficiency Monocrystalline Silicon Photo Voltaic Panel, High Efficacy Smd Led 6500K Having Secondary Lens Optics For Street Lighting Distribution, High Performance Lithium Battery, Mppt Charge Controller & Intelligent Control Module / Sensor With Higher Reliability, Long Service Life, Suitable For Easy & Quick Installation. Wipro Cat No.:Lr 14-591-Xxx-65-Xx. 2044 Supply, Testing & Commissioning Of 6.0 Meter High G.Ioctagonal Pole ( Above Ground Level ) With Single / Double Arm As Per Requirement Of Suitable Length With Inbuilt Junction Box With 10A Sp Mcb, Connectors For Incoming / Outgoing Cable Connection And 300Mm X 300Mm X 20 Mm Thick Base Plate And Bracket ( Double Arm / Single Arm Whichever Required ) Complete In All Respect. 2045 Supplying And Laying Cable Through Gi Pipe Upto Junction Box Including Excavation And Back Filling, Wiring With 2 X 2.5 Sq.Mm Pvc Insulated 1100 Volts Grade Copper Conductor Wires From Junction Box To Lighting Fixturecomplete. 2046 Sub Head -V :Earthing And Miscellaneous Items ( Non Dsr Items ) 2047 Supplying And Fixing Of High Voltage Insulation Mat Of Class B Having 1.1 Kv Dielectric Strength, 1000Mm Width And Thickness Of 2.0 Mm Isi Approved As Required Including Cutting To Required Lengths. 2048 Supplying Of Fire Bucket Painted Red With Stand And Approved Quality Conforming To Is:254 / 1974 2049 Supplying And Fixing Of Powder Fire Extinguisher ( Stored Pressure Type ) Capacity 06 Kg Duly Isi Marked Conforming To Is: 15683:2006, With Is 14609, Isi Marked Abc Powder Complete With Squeeze Grip Release Valve, Discharge Pipe, Locking Arrangement, Pressure Gauge & Suitable M.S. Bracket As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
31.
Home Affairs #9421157 Technical Bid
Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 8 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 9 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 10 Providing and laying in position cement concrete of specified grade1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). 12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level :Concrete of M10 grade with minimum cement content of 220 kg /cum 16 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M30 grade with minimum cement content of 350 kg /cum 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site Mof laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M25 grade with minimum cement content of 330 kg /cum 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M30 grade with minimum cement content of 350 kg /cum 20 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). 21 Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement : 2 coarse sand), including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landings and steps, including subsequent removal and cleaning of the same. 22 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 23 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 24 Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 25 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 26 Centering and shuttering including strutting, propping etc. and removal of form for :Shelves (Cast in situ) 27 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 28 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts 29 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 30 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 31 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 32 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 33 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 34 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 35 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 36 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 37 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 38 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 39 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 40 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 With water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer 43 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification.Two or more coats on new work 44 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work 45 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 46 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 47 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab upto 0.50 sqm 48 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm 49 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work 50 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. 52 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 53 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile 54 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. 58 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800 x 1600 mm 59 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 61 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 42x50 mm 62 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places 63 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels)made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 64 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes 65 Providing & fixing ACP Sheet with EPDM rubber gasket in groove of meeting Style clips in Aluminium doors, windows, clerestory windows,Partition all complete with :5.0 mm thick ACP Sheet 66 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 67 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 68 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :125x64x2.50 mm 69 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm 70 Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. 71 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125mm 72 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 73 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm 74 Providing and fixing ISI marked brass sliding door bolts with nuts and screws etc. complete 300x16 mm 75 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge 76 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type) 77 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete 150x125x27x5 mm 78 Providing and fixing of the MAC/VISTA/Hunter Douglas vertical Roller blinds with shade/screening and material complete with all acessories in all respect as per approved fabric/colour and texture 79 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood 50 x 20 mm 80 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 81 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 82 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global whitecolor tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 83 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 84 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 85 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 86 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm 87 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 88 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 89 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 90 Providing & fixing GRC panel (60mm thick) on external walls as per the architectural drawing. Fixing to be done on external wall including the necessary SS clamps, scaffoldings required etc. complete by specilised vendor in strict supervision of manufacturer as per direction of Engineer-in-Charge. 60 MM THICK 91 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick colour toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 92 Providing and fixing 12 mm thick frameless toughened glass Door with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 93 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishingcomplete. 94 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal sizederived from natural sources) 95 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 96 Providing and fixing 6 mm thick frameless toughened glass partation with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 97 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 98 Providing, fixing, testing and commissioning of star white colour vitreous china below / over counter Oval Wash Basin / circular basin (Size 560 x 410 mm or as/architectural detail drawing) with CP brass waste assembly complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required. 99 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for wash basins.32 mm dia 100 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect 101 Providing and fixing C.P. brass towel ring with C.P. brass wall brackets & C.P brass screws complete in all respect 102 Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete In all 103 Providing and fixing C.P. soap dish of approved make including providing & fixing screws, washers, cutting & making good the walls. 104 Providing and fixing toilet paper holder.C.P. brass 105 Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws, complete in all respect 106 Providing and fixing stainless steel kitchen sink as per I.S.13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required complete in all respect Kitchen sink with drain board 510 x 1040 bowl depth 200 mm 107 Providing, fixing, testing and commissioning of C.P. brass single hole sink mixer with CP wall flange, swinging spout complete as required and making good. 15 mm nominal dia. 108 Providing, fixing, testing and commissioning of white glazed vitreous china semi-stall lipped Urinal CI hangers CP spreader, 32/40 mm CP brass domical waste and pipe to wall with CP flange, automatic flushing system with concealed type electic operated, waterproof compact model solenoid valve with built in strainer, flow control mechnaism, stainless steel outer case, pre flush and main flush function and low battery indication, for individual urinals to ensure flushing only when in use, comprising of all plumbing & any other item required to provide satisfactory functioning as approved by the Architects complete including cutting and making good the walls and floors where required. (The gap between fixture and wall to be filled up with approved type poly sulphide sealant) Set of One urinal with flushing system. Urinal of size 580x380x350 mm or as/final architectural drawings. 109 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for urinals. 40 mm dia 110 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 111 Providing and Fixing, testing & commissioning of ABS Health Faucet (complete with hook and flexible tube min. Length 1.0 m) as required complete in all respect 112 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore 113 Providing and Fixing, testing & commissioning C.P.brass wash basin mixer 15 mm nominal bore 114 Providing and Fixing in position 15 mm C.P. brass bib cocks of best quality (as approved by theProject manager). Bib cock long body 115 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 25 litre capacity water heater 116 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 50 litre capacity water heater 117 Providing and Fixing, testing & commissioning of C.P. brass Twin way bib cock of approved quality conforming to IS standards 15 mm nominal bore 118 Providing and Fixing, testing & commissioning of C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 119 Providing and Fixing, testing & commissioning of C.P. brass towel rail fixed to rawl plug with C.P. brass screws. (600 mm long) Towel Rail 120 Providing and Fixing, testing & commissioning wall mixer with head shower & shower arm. Divertor + Spout + Shower Head 121 Providing and fixing liquid dispenser including all fittings complete. 122 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 OD 123 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 OD 124 Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. 100 mm inlet and 100 mm outlet. 125 Providing & fixing PVC EXTENSION PIECE for 100 mm dia floor trap formed out of main pipe(Type A) with multiple side inlets, suitable for various dia pipes, side connections, including all fixtures and fittings as per site conditions and as per standard 126 Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. Size 100 mm X 100 mm 127 Providing and fixing Heavy Class SS grating with of approved design including setting in floor with cement motor to match with floor finish as per architect requirement .(for Bacony or floor Drain 128 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 40 mm od uPVC pipe 129 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 50 mm od uPVC pipe 130 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63 mm od uPVC pipe 131 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 mm diameter (I) Single socketed pipes 132 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 mm diameter (I) Single socketed pipes 133 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63mm diameter (I) Single socketed pipes 134 Providing , fixing / installation, testing and commissioning of 110 mm dia straight / offset Push fit type syphon uPVC WC pan connector with neoprene rubber ring and necessary accessories etc., complete. 135 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 110 mm dia 136 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 160 mm dia 137 Providing and fixing UPVC floor drain for balcony including all fitting and accessories fixed in cement mortar complete in all respect. 63 mm OD x 50 mm OD 138 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm and down gauge). 139 Providing and making Khurras with average minimum thickness of 5 cm Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20 mm nominal size) over PVC sheet 1 m x 1 m (PVC 400 microns min. thickness), finished with 12 mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand, admixed with waterproofing compound) and a coat of neat cement, rounding the edges and making & finishing the outlet complete Khurras Size 300 x 300 mm, for 110 OD/160OD outlet with 5 mm thick circular /Square horizontal or vertical C.I. grating. 140 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm dia nominal bore 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm dia nominal bore 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm dia nominal bore 143 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm dia nominal bore 144 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm dia nominal bore 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 146 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 15 mm dia nominal bore 147 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 20 mm dia nominal bore 148 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 25 mm dia nominal bore 149 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 32 mm dia nominal bore 150 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 40 mm dia nominal bore 151 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 50 mm dia nominal bore 152 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 65 mm dia nominal bore 153 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 80 mm dia nominal bore 154 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 15 mm dia nominal bore 155 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 20 mm dia nominal bore 156 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 25 mm dia nominal bore 157 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 32 mm dia nominal bore 158 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 40 mm dia nominal bore 159 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 50 mm dia nominal bore 160 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 65 mm dia nominal bore 161 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 80 mm dia nominal bore 162 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 15 mm dia. 163 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 20 mm dia. 164 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 25 mm dia. 165 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm dia. 166 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 40 mm dia. 167 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 50mm dia. 168 Providing and fixing Solenoid valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete. 25mm dia. 169 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 65 mm dia. 170 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 80 mm dia. 171 Providing and fixing air release valve 15 mm dia 172 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 3KL 173 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 5KL 174 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 175 Extra over for item no. 1.1 excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre) Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 176 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia R.C.C pipe 177 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. Complete 250 mm dia R.C.C pipe 178 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 150 mm dia R.C.C pipe 179 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 250 mm dia R.C.C pipe 180 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With F.P.S. bricks with class designation 75 181 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks with class designation 75 182 Extra depth for manholes Size 90 x 80 cm (With With F.P.S. bricks with class designation 75) 183 Size 120 x 90 cm (With With F.P.S. bricks with class designation 75) 184 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design: With F.P.S. bricks 185 Extra depth beyond 45 cm of brick masonry chamber For 455 x 610 mm size With F.P.S. Bricks 186 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 187 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 188 Material & labour for constructing R.C.C. Grease trap of size 2000mm x 1200mm x 2500mm deep with RCC walls with inlet & outlet including necessary excavation and foundation concrete 100mm thick in 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate of 20mm nominal size), inside plaster 12mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement, RCC base slab, roof slab & baffle walls including reinforcement, centering & shuttering including 12mm dia steel bar footrests etc. and SFRC manhole cover and frame of 600mm x 450mm internal dimension conforming to IS: 12592 (total weight of cover & frame shall not be less than 70 kg) 189 Supply, instattation, Engineering, Testing and Commissioning of sewerage treatment plant all items to include providing all materials and its assembly, Labour, Consumables etc. as per standards and specifications, approved shop drawings at site.Sewage Treatment Plant (STP) using Moving Bed Bio Reactor (MBBR) or DRDO based Bio-Digester of capacity 10 KLD in civil construction and releted works including Design, Engineering, and preparation of providing all equipment / Piping etc at site, erection testing and 190 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 191 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 192 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 193 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 194 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Plug Wiring) 195 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For Single Phase DB. From Sub Panel to DB) 196 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 197 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 198 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 199 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 200 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 201 Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 202 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 203 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 204 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 205 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 206 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm 207 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet 208 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet 209 Supplying and drawing co-axial TV cable RG-6 …. in the existing surface/ recessed steel/ PVC conduit as required. 210 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 211 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 212 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way, Double door 213 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door 214 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).6 way (4 + 18), Double door 215 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door 216 12 way (4 + 36), Double door 217 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) TPDB is normally used 4 way (4 + 12), Double door 218 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 219 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 220 Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amps 221 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 222 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 223 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25/32 amps 224 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 225 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 226 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 227 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 228 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 229 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 230 Supply and installation of Kitchen Chimney with baffle filter, Stainless Steel, i/c Ducts for exhaust upto outer wall, push button operations, LED lights inclusive, noise(<60db), Exhaust area length x width (500 cmx 500cm) Exhaust motor rpm 2000 , V 220 W, >3500 cfmetc of approved brand as per directed by Engineer-in-charge. 231 Supply of 20 watt LED Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 232 Bulkhead Light. 233 Wall Bracket Light. 234 Supply of 20 watt LED FLAMEPROOF Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 235 Bollared Light. 236 LED exit signage Light. 237 Supply of recess mounting 15 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 238 Supply of 9 W mirror light with high efficient LED’s, CCT-6500 K,CRI >70, Lumens ≥800, with Ingress protection IP-20, Driver shall be of constant current type, operating temperature from -10 to +45 degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 239 Supply of recess mounting 10 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 240 Lamp Post Light. Make- Philips 241 Pendant Light. Make- Philips 242 Supply of 1200mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply with 5 star rating complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 243 Supplying of Plastic Body Ornamental Exhaust Fan heavy duty 230V A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient, complete erected in position with all accessories. 244 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness 245 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness 246 MAIN LT PANEL-1 Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. (Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel.) A INCOMER FRPM EXISTING SUPPLY;- 1 No. 400A 4P MCCB (36 KA) with electronic releases (O/C, S/C, E/F) 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 3 nos. indicating LED lamps for On/Off/ Trip with protective SP MCBs. 1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA ,1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA, 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA , 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA, 1 Set of. 400/5A , 15 VA, 5P10 CTs for Protection, 300 amps TPN Aluminium Busbar. BUSBARS - All busbars and interconnections shall be of suitable size Al strips current density of Al shall not be more than 0.8 Amps/ sq.mm. OUTGOINGS- 12 Nos. 63A (36kA) 4P MCCB., 4 Nos. 40A (36kA) 4P MCCB. ,4 Nos.32A (36kA) TPN MCB, 2 Nos.32A (10kA) DP MCB, MAIN LT PANEL as described above. Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts. 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium3.5 C x 185 sq. mm 248 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. AluminiumSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 249 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50 sq. mm 250 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 185 sq. mm 251 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 252 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50sq. mm 253 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 16 sq. mm 254 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 10sq. mm 255 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 258 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 259 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 260 Providing and fixing of lightning conductor finial, made of 25 mm dia 1200 mm long, copper tube, having single prong at top , with 85 mm dia 3 mm thick copper base plate including holes with insulation etc. complete as required. 261 Providing and fixing Copper Lightning Tape in Horizontal/Vertical Run: Providing and fixing copper tape 20mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. 262 Providing and fixing Testing Joint for Copper Lightning Conductor: Providing and fixing testing joint made of 32 mm X 6 mm thick copper strip, 125 mm long with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as required. 263 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 264 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 265 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 266 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 267 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 268 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 269 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 270 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 271 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 272 Supplying, installation, testing & commissioning of addressable phone control module complete as required. 273 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 274 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 275 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 276 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 277 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 278 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 279 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. 280 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. 281 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 282 Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm). 283 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 284 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm 285 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
32.
Rural Development #9356846 Technical Bid
Annual Plan-Project No. 237/26 - Kizhakkoth G P - Electronics Work -Supply and Installation of CCTV System in Grama Panchayat Office-General Electronics Work- 1 CCTV System 2 OD251418/2025-2026:Supply and installation of Network Video Recorder 16 Ch. 4K 2HDDs Network Video Recorder ,, and having Up to 16 channel IP camera input,Max. decoding capability: 8 × 1080p@30 fps, 2 × 8 MP@30 fps,Smart Insta stream/H.265/H.264 /MJPEG, Up to 12Mp resolution preview and playback ,Max. 160/160/80 Mbps incoming/recording/outgoing bandwidth ,Support 2 SATA HDDs up to 20TB, 2 (1 front USB 2.0 port, 1 rear USB 2.0 port) ,ONVIF Version 2.4 conformance Approved Make: CP Plus, Honeywell, Norden 3 OD251432/2025-2026:Supply and Installation of 4.0MP or higher IR POE Dome/BulletIP camera having following features:1/2.9 inch 4MP PS CMOS Image Sensor (0.8758 centimeters),3.6mm fixed Lens ,Max. 4MP (2688 × 1520)@1-25/30fps/ (2560 × 1440)@1-25/30 ,IR Range of 30 Mtr., IP67, PoE,Support Triple stream , WDR (120dB), Day/Night(ICR), 3D NR, AWB, AGC, BLC, HLC, Digital watermarking , Instastream, H.265, H.264, H.264H, H.264B, MJPEGApproved Make: CP Plus, Honeywell,Norden 4 OD251498/2025-2026:SITC of 4TB Surveillance Internal Hard Drive - 7200 RPM Class, SATA 6 GB/S, 256 MB Cache, 3.5, Etc or Better specification. Make - Western Digital/Seagate/Samsung. 5 OD251502/2025-2026:Supply and installation of16-port Gigabit Ethernet Unmanaged PoE Switch Having 76 Watts , Power Efficiency IEEE 802.3az Energy Efficient Ethernet ,Feature Category Details Ports 16 × Gigabit PoE+ ports (802.3af/at) , with3 year warranty .Approved Make: Netgear, Cisco, HP, Brocade 6 OD251518/2025-2026:Supply and fixing of 19 inch9 U rack for placing NVR ,UPS, etc with covered wire manager, AC distributionbox and all other accessories. Preferred Make. Netrack/APW/Rittal (500mm X 400mm)Netrack ,wallrack , 7 OD251523/2025-2026:Supply and installation of wireless mouse withfor NVR (includes USB Extension cable ). Preferred Make: Dell,HP,Logitech 8 OD251532/2025-2026:Supply and installation of 1.0 KVA with BIS/CE certified IGBT based On-Line UPS with 2 numbers of 12Volt 7Ah batteries including all necessary accessories. Preferred Make: Hykon, Luminous,, Zenster, Microtec 9 OD251545/2025-2026:Supply and laying high quality HDMI cable with minimum 15 meters of length. Preferred Make: MX, Logic, Honeywell 10 OD251558/2025-2026:Supply and installation of 32 inch HD LED Television having Audio/Video in and out, 2 Nos. of HDMI ports with fullfunction remote controller and having 3 year warranty, supplied with good quality HDMI cable. Approved Make: LG/ samsung / Panasonic 11 OD251563/2025-2026:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type loaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Preferred make: Molex, Comscope, Systimax 12 OD251576/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cord having LSZH jacket, 24 AWG bare copper conductor UTP 4 pair both end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint .Preferred Make:Molex, Comscope,systimax 13 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 14 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 15 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
33.
Drinking Water Supply and Sanitation #9199019 Technical Bid
Tender For The Work Of Construction Of Sources Rising Main Pl Cwrs Pump Houses Esrs Glsrs Internal Village Distribution Pipeline And Fhtc Including One Year Dlp Of Svs Under Jjm In The Dn Bagidora Under Distt Bans Pkg15 - Tender for the work of construction of Sources, Rising main pipelines, CWRs, Pump houses, ESRs, GLSRs, internal village distribution pipeline and FHTC including one year Defect Liability Period of SVS under JJM in the DN. Bagidora Under District-Banswara (Package-15) Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately 2 80 mm dia 3 100 mm dia 4 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE-100 PN-6 (Dia in mm) 5 75 mm dia 6 90 mm dia 7 110 mm dia 8 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.HDPE PE100 PN-6 (Dia in mm) 9 125 mm dia 10 160 mm dia 11 180 mm dia 12 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc. 13 In all types of Soils 14 upto 1.5 m 15 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable materials for measurements and disposal of unserviceable materials as directed within a lead of 50 Mtr. including required all safety provisions etc.: 16 In Soft Rock 17 upto 1.5 m 18 In Hard Rock (Blasting Required) 19 upto 1.5 m 20 In Hard Rock (Blasting Prohibited) 21 upto 1.5 m 22 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 23 Bituminous courses 24 Granular courses 25 Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasksas per technical specification and scope of work. 26 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 27 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mmnominal size). 28 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confiMetering to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confiMetering to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 29 80 mm dia 30 100 mm dia 31 150 mm dia 32 200 mm dia 33 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 34 Manually Operated CI Sluice valve of Class PN-1.0 35 100 mm dia 36 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 37 80 mm dia 38 100 mm dia 39 150 mm dia 40 200 mm dia 41 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. 42 100 mm dia 43 Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 44 Class PN 1.0 45 100 mm dia 46 Construction of Sluice Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in chargematerial within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge 47 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 48 1200cm x 1200cm x 1300cm (depth) for 80/100/125/150 mm dia valve 49 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 50 Class PN 1.6 51 50 mm 52 Class PN 1.0 53 40 mm 54 50 mm 55 Supply, installation, testing and commissioning of DC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and B9maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit,accidental short circuit and reverse polarity should be provided. A good reliable on/off switch suitable for DC use is to be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be as per technical specification and direction of Engineer in charge. 56 2.2 KW (3.0 HP) 57 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item. The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover.Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled. Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document. 58 5000 Liter X 2 Nos. PE water tank, staging 12 meter. 59 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. 60 Design, Fabrication and installation of MS galvanised structure for installation of Solar Penals at a height of 4m above ground level 61 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. 62 Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation of PV module on above structure as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be as per detailed technical specifications, approved drawing and direction of Engineer in Charge.This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. 63 Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height 64 Design, Fabrication and installation of MS galvanised structure for installation of Solar Penals at a height of 4m above ground level 65 120CM high fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30 cm in ground embedded in cement concrete, 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonal of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 66 Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRTH specification & type A as per IS : 278-1978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97-106 g/m) includiing all material, labour. 67 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 68 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 69 2.2 KW 70 5.5 KW 71 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 72 Up to 5.00 HP 73 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 74 Above5 HPand upto 10 HP 75 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 76 5.5 KW (7.5 HP) & head up to 120 mtr. 77 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 78 3 core 4.0 Sq.mm 79 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 80 10.0 Sq. mm 4 core 81 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 82 50 mm dia 83 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Class PN 1.6 84 100 mm dia 85 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 86 100 mm dia 87 150 mm dia 88 200 mm dia 89 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 90 80 mm dia 91 Providing , lowringlaying , aligninng, fixing in position at all level/ depthC.I. class-B specials as per IS:1538, amended up to date in trench complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical specification and as per direction of Engineer( Note:- E/W to be measured and paid seperately) plain ended CI specials including tail pice, spigot end and socket end. 92 Upto 300mm 93 Providing, lowering, laying, aligning, fixing in positionand jointing at alllevel/depthsDIstandardspecialswithrubberring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523- 2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material, labour, taxes, testingand commissioningalong with pipe line as per technicalspecificationsanddirectionofEngineer-in-charge (excluding earth work). 94 AII End Flanged 95 Upto 300mm 96 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 97 GSM Modem for SMS Facility- 24 V DC operated for bulk flow meter to transmit reading of flow meter to LCC/MCC Centre 98 Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - 99 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. 100 j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 101 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M 102 50 KL, staging Height 15 m 103 75 KL, staging Height 15 m 104 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 105 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 106 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 107 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging 108 100 KL, staging Height 18 m 109 150 KL, staging Height 18 m 110 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging 111 100 KL, staging Height 20 m 112 250 KL, staging Height 22 m (1-Nos.) 113 Providing Household Tap Connectionas per technical specification and approveddrawingasperrelevantIScode(amendeduptodate)from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanicalIntegrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , notexceedingtheflowof7LPMat2barandacompressionelbow, mouldedinsinglepiece(Completejob)includingdiggingoutsuitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specificationforpotablewaterincludingGMFull-wayValve(IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80PN16asperISO4427/20mmnominal diaPPR-C(Three layered) pipe PN16 SDR7.4 (IS:15801:2008)(ISI mark)and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premisesforfixinga tap/ meterbox (excluding),including accessories withflushing,cleaning,disinfectingandtestingofpipelinecomplete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note:Roadcutandrestorationisnotpartofthisitemandpaid separately. 114 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 115 Providing and fixing ISI mark (IS 9763: 2000 or amended upto date) PTMT bib cock 15 moinal bore minimum weight 92 gms and length 100 mm as per technical specification, approved make and direction of Engineer in charge. 116 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 117 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 118 Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe. 119 150 mm dia nominal bore. 120 Nominal bore 200 mm dia. - for 1 No. of Tube Wells for 1st 100 m 121 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. For 20 m more additional depth (total depth 120m) 122 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. For 20 m more additional depth (total depth 120m) 123 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 124 200mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 125 200 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) 126 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 127 150 mm dia 128 200 mm dia 129 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil. 130 Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All workto plinth level using crusher broken aggregate 131 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 132 M20 Grade nominal mix (with graded stone aggregate 20mmnominal size) 133 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any hickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. 134 M20 grade Nominal Mix / Design Mix 135 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 136 Columns, pillars, posts and struts etc. (Pillar above GL) 137 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 138 100 mm dia 139 150 mm dia 140 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-incharge.MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) 141 Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan)for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. 142 From0 m to 1.5 m BGL 143 Ordinary rock 144 From1.5 m to 6 m BGL 145 Hard rock (requiring blasting) usefulmaterial 30 % 146 From6 m to 7 m BGL 147 From6 m to 20 m BGL 148 Add extra over item No 1 for every additional; lift of 1.5 m or part thereof. 149 All Kind Of soilFrom1.5 m to 4.5 m BGL 150 In Ordinary RockFrom4.5 m to 6 m BGL 151 In hard rock 152 From6 m to 7.5 m BGL 153 From7.5 m to 9 m BGL 154 From9 m to 10.5 m BGL 155 From10.5 m to 12 m BGL 156 From12 m to 13.5 m BGL 157 From13.5 m to 15 m BGL 158 From15 m to 16.5 m BGL 159 From16.5 m to 18 m BGL 160 From18 m to 19.5 m BGL 161 From19.5 m to 20 m BGL 162 Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering.(Respective applicable rates)From6 m to 18 m BGL 163 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :Walls (any thickness) including attached pilasters,buttressesplinthandstring course.Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to 4.7.2 164 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 165 Thermo-mechanically Treated bars (Conforming of relevent IS code) 166 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. 167 M20 Grade nominal mix (with graded stone aggregate 20mm nominal size) 168 Structural steel work in single section fixed with connecting plate includingcutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height 169 Filling available excavated earth (excluding rock) in trenches plint side of foundation etc. in layers not extending 20cm in depth, consolidating each deposited layer by ramming & watering including lead upto 50m. 170 Labour charges for horizontal boring 100 mm dia in open well in rocky stratawith all types of rock cutting & drilling tools etc. including all T&P required for job including dewatering arrangement. 171 Earth work in excavation over areas (exceeding 30 Cm. In depth, 1.5 Mtr. In width as well as 10 Sqm. on plan) including disposal of excavated earth lead up to 50 M and lift up to 1.5 Mtr. Disposed earth to be leveled and neatly dressed:All kinds of soi 172 Random Rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in 173 In cement mortar 1:4 (1 cement : 4 coarse sand) 174 Brick masonry in partition in super structure up to third storey 7 cm thick (brick on edge) using bricks of class designation 75 in 175 Cement mortar 1:3 (1 cement : 3 coarse sand) 176 Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 177 1:4 (1 cement : 4 fine/ coarse sand) 178 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishingand reinforcement: 179 M20 (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 180 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. 181 Wall (any thickness) including attached pilasters, buttresses, plinth and string course 182 Suspended floors, roofs, landings, balconies and access platform. 183 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete 184 Thermo-Mechanically Treated bars 185 Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sheesham wood Grade-1 186 Cement concrtete grade 1:2:4 (1 Cement: 2 Coarse sand : 4 graded stone aggregate ) rounding of adeges etc.. but excluding the cost of nosing of steps etc. complete 187 75mm thick with 20mm thick nominal size aggregate 188 P & F IP-65 protected street light luminaire on existing bracket suitable for HPSV/ MH LAMP, made from powder coated single piece pressure die cast aluminium housing, electrochemically brightened and anodized POT optics aluminium reflector, heat resistant and toughened glass cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc. as required(without lamp) 189 Street Light Suitable for HPSV Lamps1 X 150 Watt 190 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked( IS:9537 P - II ) rigid steel conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch, 3.0 mm thick ISI markedphenolic laminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 191 Short point (up to 3 mtr.) 192 Medium point (up to 6 mtr.) 193 Providing and fixing, flush door shutters non decorative type (hollow core construction) with internal frame of Ist grade wood having styles and top rails of 100 mm width & bottom and lock rails of 150 mm width with 3 Nos. cross battens of 50 mm thick width using 4 mm thick commercial ply on both faces of shutters & 6 mm thick beading of respective wood using with approved steel fitting as perAnnexure A :- 194 25 mm thick. 195 Sheesham wood grade – I 196 Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board ,6 Aswitch, 6 A socket, 3.0 mm thick ISI marked phenoliclaminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 197 Short point (up to 3 mtr.) 198 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 199 4.0 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
34.
Drinking Water Supply and Sanitation #9100901 Technical Bid
Tender For Rural Water Supply Scheme For Village Amjara, Panchayat Amjara Of Block-Dungarpur Dist Dungarpur Through Fhtc Under Jal Jeevan Mission., 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382- 1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately 2 80 mm dia 3 100 mm dia 4 150 mm dia 5 200 mm dia 6 250 mm dia 7 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendeduptodate),with internalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 8 100 mm dia 9 150 mm dia 10 200 mm dia 11 250 mm dia 12 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE-100 PN-6 (Dia in mm) 13 75 mm dia 14 90 mm dia 15 110 mm dia 16 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.HDPE PE100 PN-6 (Dia in mm) 17 125 mm dia 18 140 mm dia 19 160 mm dia 20 180 mm dia 21 200 mm dia 22 225 mm dia 23 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safetyprovisions etc. 24 In all types of Soils 25 upto 1.5 m 26 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable materials for measurements and disposal of unserviceable materials as directed within a lead of 50 Mtr. including required all safety provisions etc.: 27 In Soft Rock 28 upto 1.5 m 29 In Hard Rock (Blasting Required) 30 upto 1.5 m 31 In Hard Rock (Blasting Prohibited) 32 upto 1.5 m 33 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters.Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 34 Bituminous courses 35 Granular courses 36 Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasksas per technical specification and scope of work. 37 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification andscope of work. 38 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 39 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confiMetering to BS- EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confiMetering to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 40 80 mm dia 41 100 mm dia 42 125 mm dia 43 150 mm dia 44 200 mm dia 45 250 mm dia 46 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizes includingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 47 80 mm dia 48 100 mm dia 49 125 mm dia 50 150 mm dia 51 200 mm dia 52 250 mm dia 53 Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge. 54 100mm diameter 55 Construction of Sluice Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in chargematerial within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge 56 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 57 1200cm x 1200cm x 1300cm (depth) for 80/100/125/150 mm dia valve 58 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 59 Class PN 1.6 60 50 mm 61 80 mm 62 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. 63 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. 64 Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank 65 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. 66 In flates, tees, angles & Channals 67 Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwovenwith horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRTH specification & type A as per IS : 278-1978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97-106 g/m) includiing all material, labour. 68 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 69 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 70 2.2 KW 71 3.7 KW 72 5.5 KW 73 7.5 KW 74 9.3 KW 75 11.0 KW 76 15.0 KW 77 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 78 Up to 5.00 HP 79 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gaugeM.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 80 Above5 HPand upto 10 HP 81 Above 10 HP and up to 15 HP 82 Above 15 HP and up to 20 HP 83 Above 20 HP and up to 30 HP 84 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including makingconnection etc. 85 3 core 4.0 Sq.mm 86 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. asrequired of size. 87 10.0 Sq. mm 4 core 88 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amendedup to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete inall respect. 89 32 mm dia 90 50 mm dia 91 65 mm dia 92 80 mm dia 93 Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside .Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling jointsand earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 94 Class PN 1.0 95 100 mm dia 96 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalentgrade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF- 8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside.Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6 97 80 mm dia 98 100 mm dia 99 125 mm dia 100 150 mm dia 101 200 mm dia 102 250 mm dia 103 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 104 80 mm dia 105 100 mm dia 106 125 mm dia 107 150 mm dia 108 200 mm dia 109 Providing , lowringlaying , aligninng, fixing in position at all level/ depthC.I. class-B specials as per IS:1538, amended up to date in trench complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical specification and as per direction of Engineer( Note:- E/W to be measured and paid seperately) plain ended CI specials including tail pice, spigot end and socket end. 110 Upto 300mm 111 GSM Modem for SMS Facility- 24 V DC operated for bulk flow meter to transmit reading offlow meter to LCC/MCC Centre 112 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holdingthe riser pipe assembly of submersible pump set. 113 Construction and commissioning of RCC INTZE type Over Head Service Reservoir offollowing capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 114 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M- 15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 115 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 116 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging 117 100 KL, staging Height 20 m 118 150 KL, staging Height 20 m 119 200 KL, staging Height 20 m 120 100 KL, staging Height 20 m 121 300 KL, staging Height 20 m 122 400 KL, staging Height 20 m 123 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging 124 100 KL, staging Height 18 m 125 150 KL, staging Height 18 m 126 200 KL, staging Height 18 m 127 250 KL, staging Height 18 m 128 300 KL, staging Height 18 m 129 400 KL, staging Height 18 m 130 Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - 131 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M- 15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. 132 j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 133 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M 134 50 KL, staging Height 15 m 135 75 KL, staging Height 15 m 136 Providing Household Tap Connectionas per technical specification and approveddrawing asperrelevantIScode(amendeduptodate)from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanicalIntegrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceedingtheflowof7LPMat2barandacompressionelbow, mouldedinsingle piece(Completejob)includingdiggingoutsuitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming/compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specificationfor potablewaterincludingGMFull-wayValve(IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80PN16asperISO4427/20mmnominal diaPPR-C(Three layered) pipe PN16 SDR7.4 (IS:15801:2008)(ISI mark)and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premisesforfixinga tap/ meterbox (excluding),including accessories withflushing,cleaning, disinfectingandtestingofpipelinecomplete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note:Roadcutandrestorationisnotpartofthis itemandpaid separately. 137 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 138 Providing and fixing ISI mark (IS 9763: 2000 or amended upto date) PTMT bib cock 15 moinal bore minimum weight 92 gms and length 100 mm as per technical specification,approved make and direction of Engineer in charge. 139 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 140 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 141 M20 grade Nominal Mix 142 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 143 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil asdirected with in lead of 50 mtr. All kinds of soil. 144 Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All workto plinth level usingcrusher broken aggregate 145 M10 grade Nominal Mix ( with graded stone aggregate 20mm nominal size) 146 M15 grade Nominal Mix ( with graded stone aggregate 20mm nominal size) 147 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases ofcolumns etc. 148 P & F on wall face A.C. pipes (IS : 1626 part-I mark) of approved make with wooden plugs and M.S. clamps, jointing with spun yarn soaked in bitumen and C.M. 1:2 complete includingmaking good the wall.: 100mm dia. 149 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 150 100 mm dia 151 150 mm dia 152 200 mm dia 153 250 mm dia 154 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-incharge.MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) 155 Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan)for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. 156 From0 m to 1.5 m BGL 157 Ordinary rock 158 From1.5 m to 6 m BGL 159 Hard rock (requiring blasting) usefulmaterial 30 % 160 From6 m to 7 m BGL 161 From7 m to 20 m BGL 162 Add extra over item No 1 for every additional; lift of 1.5 m or part thereof. 163 All Kind Of soil 164 In Ordinary Rock 165 In hard rock 166 From4.5 m to 6.0 m BGL 167 From6.0 m to 7.5 m BGL 168 From7.5 m to 9.0 m BGL 169 From9.0 m to 10.50 m BGL 170 From10.50 m to 12.0 m BGL 171 From12.0 m to 13.50 m BGL 172 From13.50 m to 15.0 m BGL 173 From15.0 m to 16.50 m BGL 174 From16.50 m to 18.0 m BGL 175 From18.0 m to 20 m BGL 176 Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering.(Respective applicable rates)From6 m to 18 m BGL 177 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :Walls (any thickness) including attached pilasters,buttressesplinthandstring course.Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to4.7.2 178 Addextra for shuttering in circular work in plan upto dia 10m on item no. 4.7.1 179 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floorthree level. 180 Thermo-mechanically Treated bars (Conforming of relevent IS code) 181 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost ofcentering, shuttering and reinforcement. 182 Walls (any thickness) including attached pilasters buttresses, plinth and string courses filletscolumns pillars pears abutments posts struts etc. 183 M20 Grade nominal mix (with graded stone aggregate 20mm nominal size) 184 Structural steel work in single section fixed with connecting plate includingcutting hoistingfixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height 185 Filling available excavated earth (excluding rock) in trenches plint side of foundation etc. in layers not extending 20cm in depth, consolidating each deposited layer by ramming &watering including lead upto 50m. 186 Labour charges for horizontal boring 100 mm dia in open well in rocky stratawith all types of rock cutting & drilling tools etc. including all T&P required for job including dewateringarrangement. 187 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.300 mm Dia 8 mm thick casing pipe with protective coating. 188 AIR PILLAR 189 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 190 upto 1.5 mtrs 191 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 192 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. 193 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any hickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 194 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases ofcolumns etc. 195 Footing PCC 196 Base Slab 197 Pillar below GL 198 Total 199 Columns, pillars, posts and struts etc. (Pillar above GL) 200 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) 201 River/Canal Crossing Estimate 202 Earth work in excavation over areas (exceeding 30cm in depth, 1.5 Mtr. in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50m and with all liftdisposed earth to be levelled and neatly dressed: 203 Pumping out water caused by springs, tidal or river seepage, broken water mains or drainsand the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete. 204 5 - 9 HP 205 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 206 M10 grade Nominal Mix (with graded stone aggregate 20mm nominal size). 207 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost ofcentering, shuttering and reinforcement. M25 208 Footing 209 Column upto GL 210 Column above GL 211 Subtotal 212 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 213 Centering and Shuttering with plywood or steel sheets including strutting, propping bracingboth ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level. 214 Footing 215 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for : 216 Column 217 Columns, pillars, posts and struts etc. 218 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 219 Thermo-mechanically Treated bars (Conforming of relevent IS code) 220 Provision for construction of switch room of size (4m x 3 m) 221 Earth work in excavation over areas (exceeding 30 Cm. In depth, 1.5 Mtr. In width as well as 222 Random Rubble stone masonry for foundation and plinth in cement sand mortar above 30cm thick wall in 223 In cement mortar 1:6 (1 cement : 6 coarse sand) 224 Honey comb brick work 23 cm thick with bricks of class designation 75 up to third storey in : 225 Cement mortar 1:4 (1 cement : 4 coarse sand) 226 Deduction of Door 227 Deduction of Window 228 Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc.complete fine finish : (12mm thick) 229 1:4 (1 cement :4 fine/ coarse sand) 230 Deduction of Door 231 Deduction of Window 232 Cement concrtete grade 1:2:4 (1 Cement: 2 Coarse sand : 4 graded stone aggregate ) 233 75mm thick with 20mm thick nominal size aggregate 234 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishingand reinforcement: 235 M20 grade Design mix (with weight batching plant only) 236 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strapbeams, bases of columns , etc. up to plinth level. 237 Wall (any thickness) including attached pilasters, buttresses, plinth and string course 238 Suspended floors, roofs, landings, balconies and access platform. 239 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing inposition and binding all complete 240 Thermo-Mechanically Treated bars 241 Providing & fixing door, window, chowkhats and other frames, including antitermite treatment,M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sheesham wood Grade-1 242 P & F IP-65 protected street light luminaire on existing bracket suitable for HPSV/ MH LAMP, made from powder coated single piece pressure die cast aluminium housing, electrochemically brightened and anodized POT optics aluminium reflector, heat resistant and toughened glass cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc.as required(without lamp) 243 Street Light Suitable for HPSV Lamps1 X 150 Watt 244 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked( IS:9537 P - II ) rigid steel conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch, 3.0 mm thick ISI markedphenolic laminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 245 Short point (up to 3 mtr.) 246 Medium point (up to 6 mtr.) 247 Providing and fixing, flush door shutters non decorative type (hollow core construction) with internal frame of Ist grade wood having styles and top rails of 100 mm width & bottom and lock rails of 150 mm width with 3 Nos. cross battens of 50 mm thick width using 4 mm thick commercial ply on both faces of shutters & 6 mm thick beading of respective wood using with approved steel fitting as perAnnexure A :- 248 25 mm thick. 249 Sheesham wood grade – I 250 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18 SWGG.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 251 Short point (up to 3 mtr.) 252 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 253 2 x 1.5 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
39.
Drinking Water Supply and Sanitation #8962396 Technical Bid
Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5 ( I ) 8 Mm Dia Wt. Not Less Than 400 Gms 6 ( Ii ) 10 Mm Dia Wt. Not Less Than 400 Gms 7 ( Iii ) 15 Mm Dia Wt. Not Less Than 400 Gms 8 ( Iv ) 20 Mm Dia Wt. Not Less Than 600 Gms 9 ( V ) 25 Mm Dia Wt. Not Less Than 900 Gms 10 M923stop Cocks 11 ( I ) 15 Mm Brass Stop Cock Wt. Not Less Than 300 Gms 12 ( Ii ) 20 Mm Brass Stop Cock Wt. Not Less Than 400 Gms 13 ( Iii ) 25 Mm Brass Stop Cock Wt. Not Less Than 575 Gms 14 ( Iv ) 32 Mm Brass Stop Cock Wt. Not Less Than 850 Gms 15 ( V ) 40 Mm Brass Stop Cock Wt. Not Less Than 1.15 Kg 16 ( Vi ) 50 Mm Brass Stop Cock Wt. Not Less Than 2.15 Kg 17 ( Vii ) 15 Mm Dia C.I. Body Brass Working Part Stop Cock. 18 ( Viii ) 20 Mm Dia C.I. Body Brass Working Part Stop Cock. 19 ( Ix ) 25 Mm Dia C.I. Body Brass Working Part Stop Cock. 20 M924g.M. Full Way Valve 21 ( I ) 15 Mm Dia Wt. Not Less Than 300 Gms Without Wheel 22 ( Ii ) 20 Mm Dia Wt. Not Less Than 400 Gms Without Wheel 23 ( Iii ) 25 Mm Dia Wt. Not Less Than 500 Gms Without Wheel 24 ( Iv ) 32 Mm Dia Wt. Not Less Than 700 Gms Without Wheel 25 ( V ) 40 Mm Dia Wt. Not Less Than 1.0 Kg Without Wheel 26 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.4 Kg Without Wheel 27 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.8 Kg Without Wheel 28 ( Viii ) 80 Mm Dia Wt. Not Less Than 2.5 Kg Without Wheel 29 M925g.M. Non Return Valve Vertical 30 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 31 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 32 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 33 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 34 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 35 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 36 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 37 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 38 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 39 M926g.M. Non Return Valve Horizontal 40 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 41 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 42 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 43 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 44 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 45 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 46 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 47 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 48 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 49 M927 Cocks 50 ( I ) 15 Mm Dia G.M. Bib Cock Wt. Not Less Than 300 Gms 51 ( Ii ) 15 Mm Dia Brass Bib Cock Wt. Not Less Than 400 Gms 52 ( Iii ) 15 Mm Dia C.I. Bib Cock Wt. Not Less Than 400 Gms 53 ( Iv ) 15 Mm Dia C.I. Body Brass Working Part Spray Painted Bib Cock Wt. Not Less Than 400 Gms 54 ( V ) 15 Mm Dia C.I. Brass Pillar Cock Cock Wt. Not Less Than 400 Gms 55 ( Vi ) 15 Mm C.I. Plug Cock Ordinary 56 ( Vii ) 15 Mm C.I. Push Cock Ordinary 57 M928chromium Plated Brass Fittings 58 ( I ) C.P. Shower Rose 100 Mm Dia 59 ( Ii ) C.P. Shower Rose 125 Mm Dia 60 ( Iii ) P.V.C. Shower Rose 150 Mm Dia 61 ( Iv ) P.V.C Shower Rose 125 Mm Dia 62 M929connection Pipe 63 ( I ) 15 Mm Dia X 30 Cm. Long Lead Connection Pipe With Brass Fittings. 64 ( Ii ) 15 Mm Dia X 45 Cm. Long Lead Connection Pipe With Brass Fittings. 65 ( Iii ) 15 Mm Dia X 30 Cm. Long Pvc Connection Pipe With Brass Fittings. 66 ( Iv ) 15 Mm Dia X 45 Cm. Long Pvc Connection Pipe Withbrass Fittings. 67 M930g.I. Fittings ( Conforming To I.S. - 1879 ) Isi Marked 68 [ A ] G.I. Bend 69 ( I ) 15 Mm 70 ( Ii ) 20 Mm 71 ( Iii ) 25 Mm 72 ( Iv ) 32 Mm 73 ( V ) 40 Mm 74 ( Vi ) 50 Mm 75 ( Vii ) 65 Mm 76 ( Viii ) 80 Mm 77 ( Ix ) 100 Mm 78 ( X ) 125 Mm 79 ( Xi ) 150 Mm 80 [ B ] Elbow Of The Following Sizes 81 ( I ) 15 Mm 82 ( Ii ) 20 Mm 83 ( Iii ) 25 Mm 84 ( Iv ) 32 Mm 85 ( V ) 40 Mm 86 ( Vi ) 50 Mm 87 ( Vii ) 65 Mm 88 ( Viii ) 80 Mm 89 ( Ix ) 100 Mm 90 ( X ) 125 Mm 91 ( Xi ) 150 Mm 92 [ C ] Tee Plain Of The Following Sizes 93 ( I ) 15 Mm 94 ( Ii ) 20 Mm 95 ( Iii ) 25 Mm 96 ( Iv ) 32 Mm 97 ( V ) 40 Mm 98 ( Vi ) 50 Mm 99 ( Vii ) 65 Mm 100 ( Viii ) 80 Mm 101 ( Ix ) 100 Mm 102 ( X ) 125 Mm 103 ( Xi ) 150 Mm 104 [ D ] Reducing Tee Plain Of The Following Sizes ( Taking Larger Dimension ) 105 ( I ) 20 Mm 106 ( Ii ) 25 Mm 107 ( Iii ) 32 Mm 108 ( Iv ) 40 Mm 109 ( V ) 50 Mm 110 ( Vi ) 65 Mm 111 ( Vii ) 80 Mm 112 ( Viii ) 100 Mm 113 ( Ix ) 125 Mm 114 ( X ) 150 Mm 115 [ E ] Socket Plain Of The Following Size ( Taking Larger Dimension ) 116 ( I ) 15 Mm 117 ( Ii ) 20 Mm 118 ( Iii ) 25 Mm 119 ( Iv ) 32 Mm 120 ( V ) 40 Mm 121 ( Vi ) 50 Mm 122 ( Vii ) 65 Mm 123 ( Viii ) 80 Mm 124 ( Ix ) 100 Mm 125 ( X ) 125 Mm 126 ( Xi ) 150 Mm 127 [ F ] Reducing Socket Plain Of The Following Sizes ( Taking Larger Dimension ) 128 ( I ) 20 Mm 129 ( Ii ) 25 Mm 130 ( Iii ) 32 Mm 131 ( Iv ) 40 Mm 132 ( V ) 50 Mm 133 ( Vi ) 65 Mm 134 ( Vii ) 80 Mm 135 ( Viii ) 100 Mm 136 ( Ix ) 125 Mm 137 ( X ) 150 Mm 138 [ G ] Union Socket Of The Following Sizes 139 ( I ) 15 Mm 140 ( Ii ) 20 Mm 141 ( Iii ) 25 Mm 142 ( Iv ) 32 Mm 143 ( V ) 40 Mm 144 ( Vi ) 50 Mm 145 ( Vii ) 65 Mm 146 ( Viii ) 80 Mm 147 ( Ix ) 100 Mm 148 ( X ) 125 Mm 149 ( Xi ) 150 Mm 150 [ H ] Plugs Of The Following Sizes 151 ( I ) 15 Mm 152 ( Ii ) 20 Mm 153 ( Iii ) 25 Mm 154 ( Iv ) 32 Mm 155 ( V ) 40 Mm 156 ( Vi ) 50 Mm 157 ( Vii ) 65 Mm 158 ( Viii ) 80 Mm 159 ( Ix ) 100 Mm 160 ( X ) 125 Mm 161 ( Xi ) 150 Mm 162 [ I ] Jam Nuts Of The Following Sizes 163 ( I ) 15 Mm 164 ( Ii ) 20 Mm 165 ( Iii ) 25 Mm 166 ( Iv ) 32 Mm 167 ( V ) 40 Mm 168 ( Vi ) 50 Mm 169 ( Vii ) 65 Mm 170 ( Viii ) 80 Mm 171 ( Ix ) 100 Mm 172 ( X ) 125 Mm 173 ( Xi ) 150 Mm 174 [ J ] G.I. Nipple Of The Following Sizes 175 ( I ) 15 Mm Dia X 100 Mm Long 176 ( Ii ) 20 Mm Dia X 100 Mm Long 177 ( Iii ) 25 Mm Dia X 100 Mm Long 178 ( Iv ) 32Mm Dia X 100 Mm Long 179 ( V ) 40 Mm Dia X 100 Mm Long 180 ( Vi ) 50 Mm Dia X 100 Mm Long 181 ( Vii ) 65 Mm Dia X 100 Mm Long 182 ( Viii ) 80 Mm Dia X 100 Mm Long 183 ( Ix ) 100 Mm Dia X 100 Mm Long 184 [ K ] G.I. Pipes Midium ( Tata Mark ) Or Equivalent As Per Is-1239 ( Part-01 ) / 2004 Isi Marked / Medium Quality 185 ( I ) 15 Mm Dia 186 ( Ii ) 20 Mm Dia 187 ( Iii ) 25 Mm Dia 188 ( Iv ) 32 Mm Dia 189 ( V ) 40 Mm Dia 190 ( Vii ) 65 Mm Dia 191 M931mirrors 192 ( A ) Mirror Of 6 Mm Thick Plain Glass 600 Mm X 450 Mm Beveled Edge Mirror Includingc.P. Brass Revolving Fittings 3 Mm Plywood Boardand C.P. Hinges Etc.To Fix The Mirror 193 ( B ) -Do- 450 Mm X 300 Mm -Do- 194 M932 ( A ) Glass Shelf 600 Mm X 125 Mm With C.P. Brass Rail 195 ( B ) -Do- 450 Mm X 125 Mm -Do- 196 M933 ( A ) C.P. Brass Towel Rail 20 Mm X 600 Mm With Bracket All Complete 197 ( B ) Anodized Aluminum 20 Mm X 600 Mm Towel Rail Complete With Brackets 198 M934c.P. Brass Soap Dish Medium Quality With Screw Andhinges Etc. 199 M935c.P. Liquid Soap Solution Holder 200 M936vitreous White Glazed Indian Water Closet Of Hindustan / Parry Ware / Cera / Naycer Or Anyotherequivalent Make 201 ( A ) 580 Mm Long 202 ( B ) 510 Mm Long 203 ( C ) 450 Mm Long 204 ( D ) 510 Mm Long White Glazed Fiber I.W.C 205 M937pair Of Vetreous White Glazed Foot Rest Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 206 M93815 Liters Capacity Pull And Let Go High Level C.I. Cistern Complete With Ball Cock And A Pair Of Bracket 207 M939 ( A ) 12.5 Liters Lowdown C.I. Cistern 208 ( B ) 10.0 Liters Capacity P.V.C. Low Design Cistern 209 M940 ( A ) White Glazed Vitreous E.W.C With P Trap Orany Other Equivalent Make 210 ( B ) E.W.C With S Trap 400 Mm High Of Hindustan / Parry Ware / Cera / Naycear Or Any Other Equivalent Make 211 ( C ) Black / White Plastic Seat For E.W.C -Do- As Above. 212 M941 ( A ) White Glazed Vitreous Earthen Were Urinal Flat Back Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 600 Mm X 350 Mm Size 213 ( B ) -Do- Squatting Small 450 Mm X 350 Mm 214 ( C ) -Do- Squatting Large 600 Mm X 350 Mm 215 ( D ) White Glazed Vitreous Earthen Ware Urinal Standing Corner Size 600 Mm X 350 Mm Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 216 ( E ) Partition Plate For Urinal 25 X 13 Size 217 ( F ) 5 Liters C.I. Automatic Cistern With All P.V.C Fittings 218 M942white Glazed Vitreous Wash Hand Basin 550 Mm X 400Mm Size Of Hindustan / Parryware / Cera / Naycer Or Any Otherequivalent Make 219 M943white Glazed Vitreous Earthen Ware Kitchensinks Of Hindustan / Parryware / Cera / Nayceror Any Other Equivalent Make 220 ( A ) Kitchen Sink 600 Mm X 450 Mm X 200 Mm ( 24 X 18 X 8 ) 221 ( B ) Kitchen Sink 600 Mm X 450 Mm X 250 Mm ( 24 X 18 X 10 ) 222 ( C ) Lab Sink 450 Mm X 300 Mm X 150 Mm ( 18 X 12 X 6 ) 223 ( D ) Lab Sink 300 Mm X 250 Mm X 150 Mm ( 12 X 10 X 6 ) 224 M944drain Board 225 ( A ) 600 Mm X 450 Mm ( 24 X 18 ) 226 ( B ) 525 Mm X 450 Mm ( 21 X 18 ) 227 M945h.C.I. Pipes 228 ( A ) 50 Mm Dia Single Socket 6-0 ( With Ear Weight 13 Kg ) 229 ( B ) 80 Mm Dia Single Socket 6-0 ( With Ear Weight 18 Kg ) 230 ( C ) 100 Mm Dia Single Socket 6-0 ( With Ear Weight 23 Kg ) 231 ( D ) 150 Mm Dia Single Socket 6-0 ( With Ear Weight 30 Kg ) 232 ( E ) 50 Mm Dia Double Socket 6-0 ( With Ear Weight 14 Kg ) 233 ( F ) 80 Mm Dia Double Socket 6-0 ( With Ear Weight 19 Kg ) 234 ( G ) 100 Mm Dia Double Socket 6-0 ( With Ear Weight 25 Kg ) 235 ( H ) 150 Mm Dia Double Socket 6-0 ( With Ear Weight 13 Kg ) 236 ( I ) 50 Mm Dia Single Socket 3-0 ( With Ear Weight 7.25 Kg ) 237 ( J ) 80 Mm Dia Single Socket 3-0 ( With Ear Weight 10.5 Kg ) 238 ( K ) 100 Mm Dia Single Socket 3-0 ( With Ear Weight 13.75 Kg ) 239 ( L ) 150 Mm Dia Single Socket 3-0 With Ear 240 ( M ) 50 Mm Dia Single Socket 2-0 ( With Ear Weight 5.35 Kg ) 241 ( N ) 80 Mm Dia Single Socket2-0 ( With Ear Weight 8.00 Kg ) 242 ( O ) 100 Mm Dia Single Socket 2-0 ( With Ear Weight 10.10 Kg ) 243 ( P ) 150 Mm Dia Single Socket 2-0 With Ear 244 ( Q ) 50 Mm Dia Single Socket 1-0 ( With Ear Weight 3.4 Kg ) 245 ( R ) 80 Mm Dia Single Socket 1-0 ( With Ear Weight 5.50 Kg ) 246 ( S ) 100 Mm Dia Single Socket 1-0 ( With Ear Weight 7.60 Kg ) 247 ( T ) 150 Mm Dia Single Socket 248 M946h.C.I. Fittings. 249 ( I ) Plain Bend Of Following Size 250 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.75 Kg ) 251 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.5 Kg ) 252 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 253 ( D ) 150 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 254 ( Ii ) Bend With Door With Following Size 255 ( A ) 50 Mm Dia ( Wight Without Ear And Socket 2.75 Kg ) 256 ( B ) 80 Mm Dia ( Wight Without Ear And Socket 4.00 Kg ) 257 ( C ) 100 Mm Dia -Do- 5.5 Kg 258 ( D ) 150 Mm Dia -Do- 259 ( Iii ) Single Junction With Door Of Followings Sizes. 260 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 3.75 Kg ) 261 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 6.50 Kg ) 262 ( C ) 100 Mm Dia -Do- 9.50 Kg 263 ( D ) 150 Mm Dia -Do- 264 ( Iv ) Double Junction With Door Of Following Sizes. 265 ( A ) 50 Mm Dia -Do- 4.5 Kg 266 ( B ) 80 Mm Dia -Do- 7.00 Kg 267 ( C ) 100 Mm Dia -Do- 13.00 Kg 268 ( D ) 150 Mm Dia -Do- 269 ( V ) Heel Rest Bend Of Following Sizes 270 ( A ) 50 Mm Dia 271 ( B ) 80 Mm Dia 272 ( C ) 100 Mm Dia 273 ( D ) 150 Mm Dia 274 ( Vi ) Cowel Of Following Sizes 275 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.25 Kg ) 276 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 277 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 278 ( D ) 150 Mm Dia -Do- 279 ( Vii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.5 Kg 280 ( Viii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.8 Kg 281 ( Ix ) 100 Mm X 80 Mm Floor Trap ( Weight Without Ear And Socket ) 4.00 Kg 282 ( X ) Pass Over 50 Mm X 150 Mm For 50 Mm Projection 283 ( Xi ) -Do- 100 Mm X 150 Mm For 100 Mm Projection 284 ( Xii ) Inverted Junction Single 100 Mm X 50 ( Weight Without Ear And Socket ) 9.0 Kg 285 ( Xiii ) Inverted Junction Double 100 Mm X 50 Mm X 50 Mm ( Weight Without Ear And Socket ) 12.0 Kg 286 ( Xiv ) H.C.I. Offset 80 Mm Projection Of The Following Size 287 ( A ) 50 Mm Dia ( Weight Without Ear And Socket ) 2.75 Kg 288 ( B ) 80 Mm Dia -Do- 3.50 Kg 289 ( C ) 100 Mm Dia -Do- 5.00 Kg 290 ( D ) 150 Mm Dia -Do- 291 ( Xv ) H.C.I. Socket Of Following Sizes 292 ( A ) 50 Mm Dia ( Weight Without Ear ) 1.50 Kg 293 ( B ) 80 Mm Dia ( Weight Without Ear ) 3.00 Kg 294 ( C ) 100 Mm Dia ( Weight Without Ear ) 4.50 Kg 295 ( D ) 150 Mm Dia ( Weight Without Ear ) -Do- 296 M947c.I. Cover With Frame For Manhole And Inspection Chamber 297 ( A ) 600 Mm X 450 Mm Size ( Wt. 39 Kg ) 298 ( B ) 600 Mm X 450 Mm Size ( Wt. 25 Kg ) 299 ( C ) 500 Mm X 450 Mm Size ( Wt. 25 Kg ) 300 M948c.I. Bracket Pair For W.H.B 301 ( A ) 550 Mm X 400 Mm Size ( 22 X 16 ) 302 ( B ) -Do- For 12.5 Liter Cistern 303 ( C ) -Do- For 600 Mm X 450 Mm ( 24 X 18 ) Sink 304 ( D ) 40 Mm X 60 Mm Ms Plate Bracket For Sink As Above 305 M949 ( A ) 32 Mm ( 1 1 / 4 ) C.P. Brass Waste For W.H.B 306 ( B ) 40 Mm ( 1 1 / 2 ) C.P. Brass Waste For W.H.B For Sink 307 ( C ) 32 Mm ( 1 1 / 4 ) C.P. Waste Of White Metal 308 ( D ) 40 Mm ( 1 1 / 2 ) C.P. Waste Of White Metal 309 M950 ( A ) 32 Mm ( 1 1 / 4 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) Withbrass Union For W H B 310 ( B ) 40 Mm ( 1 1 / 2 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) With Brass Union For W H B 311 M95132 Mm ( 1 1 / 4 ) P.V.C. Telescopic Flush Pipe With Brass Union For High Level Cistern 312 M952rubber Inserttion 3 Mm ( 1 / 8 ) Thick 313 M953pig Lead 314 M954yarn 315 M955rubber Gasket For D.I Pipe Of Good Quality 316 ( A ) 80 Mm 317 ( B ) 100 Mm 318 ( C ) 125 Mm 319 ( D ) 150 Mm 320 ( E ) 200 Mm 321 ( F ) 250 Mm 322 ( G ) 300 Mm 323 ( H ) 350 Mm 324 ( I ) 400 Mm 325 ( J ) 450 Mm 326 ( K ) 500 Mm 327 ( L ) 600 Mm 328 ( M ) 700 Mm 329 ( N ) 750 Mm 330 ( O ) 800 Mm 331 ( P ) 900 Mm 332 ( Q ) 1000 Mm 333 ( R ) 1200 Mm 334 M956cotton Waste 335 M957asbestos Suta ( Gland Packing ) 336 M958solvent Cement 337 M959hydrocloric Acid ( Sepecific Gravity 1.20 ) 338 M960cp & Pvc Fitting 339 ( I ) 32 Mm Dia C.P. Waste 340 ( Ii ) 32 Mm Dia Pv C Waste Pipe 750 Mm Long With Coupling 341 ( Iii ) 40 Mm Dia C.P. Waste 342 ( Iv 40 Mm Dia Pvc Waste Pipe 750 Mm Long With Coupling 343 ( V 100 Mm Dia Steel Jali 344 ( Vi ) 15 Mm Dia C.P. Nipple With Coupling ( Short Pieces ) 345 ( Vii ) 50 Mm Dia Pvc Pipe With Coupling 346 M961special Type Of C.P. Bath Room Fittings For V.I.P.Buildings ( Jal, Jaquar, Marc Or Equivalent Mark ) 347 ( I ) Pillar Cock ( Isi ) 348 ( Ii ) Pillar Cock ( Long Neck ) 349 ( Iii ) Bib Cock ( Isi ) 350 ( Iv ) Bib Cock ( Long Thread ) 351 ( V ) Angular Stop Cock 352 ( Vi ) Angular Stop Cock ( Long Thread ) 353 ( Vii ) Concealed Stop Cock Reduce ( Isi ) 354 ( Viii ) Concealed Stop Cock Heavy-Duty Extra Adjustable Wall Flange 355 ( Ix ) Long Body Bib Cock 356 ( X ) Swan Neck Tap With Left Hand Operating Knob 357 ( Xi ) Central Hole Basin Mixer ( Best Quality ) 358 ( Xii ) Wall Mixer With Telephonic Shower Arrangement 359 ( Xiii ) Wall Mixer With Provision For Over Head Shower With Elbow Coupling And Well Flange 360 ( Xiv ) Wall Mixer 3 In 1 System With Provision For Over Head Shower With Elbow Coupling And Wall Flange 361 ( Xv ) Sink Mixer With Swinging Casted Spout 362 ( Xvi ) Sink Cock With Swinging Casted Spout 363 ( Xvii ) 4 - Way Diverter For Concealed Fittings 364 ( Xviii ) Pressure Adjustable Shower With Revolving Joint 365 ( Xix ) Telephone Shower With Flexible Pipe 366 ( Xx ) Flush Cock With Wall Flange ( 25 Mm ) 367 ( Xxi ) Towel Rail 24 368 ( Xxii ) Towel Ring 369 ( Xxiii ) Soap Dish 370 ( Xxiv ) Tumbler Holder 371 ( Xxv ) Toilet Paper Holder 372 ( Xxvi ) Glass Shelf 22 373 ( Xxvii ) Corner Glass Shelf With Bracket 374 ( Xxviii ) Flush Valve Complete With 32 Mm Size Controlcock & Flange 375 M962c.I Special & Pvc Pipes 376 1. C.I Double Shocketted Fittings Bend Such As Bend, Tee, Taper, 377 ( A ) 80-200 Mm 378 ( B ) 250-700 Mm 379 ( C ) 700-1000 Mm 380 2. C.I Double Flange Fittings Such As Tee, Taper, Tailpiece, Bend Etc 381 ( A ) 80-200 Mm 382 ( B ) 250-700 Mm 383 ( C ) 700-1000 Mm 384 Spare Parts Of Hand Pump 385 M963hexagonal Bolt M12x1.75X40mm Long Common To Marks Ii & Iii 386 M964hexagonal Nut M12x1.75Mm 387 M965washer M12 ( 2.5Mm Thick ) 388 M966high Tensile Bolt M10x1.5X40mm Long. 389 M967nyloc Nut M10x1.5Mm 390 M968handle Axle ( Stainless Steel ) 391 M969washer For Handle Axle ( 4Mm Thick ) 392 M970ball Bearing 6204 Z 393 M971spacer For Handle. 394 M972chain With Coupling. 395 M973hexagonal Bolt For Front Cover M12x1.75Mm Long. 396 M974nitrile Rubber Cup Washer For Mark – Ii & Iii 397 M975nitrile Sealing Ring Mark – Ii 398 M976nitrile Rubber Seating Big For Lower Valve Mark-Ii 399 M977nitrile Rubber Seating Small For Upper Valve Mark-Ii. 400 M978hexagonal Rod Coupling M12x1.75X50mm Long. 401 M979pump Head Assembly ( G.I. ) With Front Cover, Bolt & Third Plate. 402 M980front Cover ( G.I. ) 403 M981handle Assembly ( G.I. ) 404 M982 ( A ) Water Tank Assemblyfor Mark – Ii ( G.I. ) 405 ( B ) Water Tank Assembly For Mark – Iii ( Vlom-65 ) 406 M983stand Assembly ( G.I. ) Normal. 407 M984stand Assembly ( Telescopic ) ( G.I ) . 408 M985connecting Rod 3Mtr. Long With Coupling And Nut ( Electrogalvanized ) 409 M986a ) Cylinder Assembly Complete Set For Mark-Ii 410 B ) Cylinder Assembly Complete Set For Mark-Iii ( Vlom-65 ) 411 M987a ) Upper Valve Assembly Complete Set For India Mark-Ii 412 B ) Upper Valve Assembly Complete Set For India Mark-Iii ( Vlom-65 ) 413 M988a ) Lower Valve Assembly Complete Set For India Mark-Ii 414 B ) Lower Valve Assembly Complete Set For Im-Iii 415 M989reducer Cap For Cylinder Mark-Ii 416 M990a ) Plunger Rod ( S.S. ) For Mark – Ii 417 B ) Plunger Rod ( S.S. ) For Mark – Iii 418 M991upper Valve Guide ( G.M. ) . 419 M992rubber Seat Retainer For Mark-Ii 420 M993third Plate For Head Assembly ( Galanized ) 421 M994cylinder Body With Brass Liner For Im-Ii With Reducer Cap For Top And Bottom. 422 M995gun Metal Spacer. 423 M996check Valve Guide Mark-Ii 424 M997a ) Check Valve Seat For Mark – Ii 425 B ) Check Valve Seat For Mark – Iii 426 M998nitrile Rubber “O” Ring ( Vlom-65 ) 427 M999push Rod For Mark – Iii ( S.S ) . 428 M1000check Nut For Push Rod ( S.S. ) . 429 M1001nitrile Rubber Cup Washer For Vlom-50 430 M1002nitrile Rubber Sealing Ring For Mark – Iii Vlom-65 431 M1003nitrile Rubber Seating Big For Lower Valve Mk-Ii 432 M1004nitrile Rubber Seating Big For Lower Valve M-Iii Vlom-65 ) 433 M1005nitrile Rubber Bobbin Vlom-50 434 M1006nitrile Rubber “O” Ring Vlom-50 435 M1007nitrile Rubber Cone For Vlom-50 436 M1008nitrile Rubber Cone For Vlom-65 437 M1009nitrile Rubber Centralizer 150Mm For ( Vlom-65 ) . 438 M1010nitrile Rubber Centralizer 125Mm For ( Vlom-65 ) . 439 M1011nitrile Rubber Centralizer 150Mm For ( Vlom-50 ) . 440 M1012nitrile Rubber Centralizer 125Mm For Vlom-50 441 M1013nitrile Rubber Centralizer 100Mm For Vlom-50 442 M1014water Tank Assembly Mark – Iii Vlom-50 443 M1015cylinder Assembly Complete Set For Mark – Iii ( Vlom-50 ) 444 M1016upper Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 445 M1017lower Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 446 M1018a ) Upper Cap Cylinder Mark – Iii ( Vlom-65 ) 447 B ) Upper Cap Cylinder Mark – Iii ( Vlom-50 ) 448 M1019a ) Bottom Cap For Mark – Iii ( Vlom-50 ) 449 B ) Bottom Capfor Mark – Iii ( Vlom-65 ) 450 M1020follower For Im-Iii 451 M1021cage For Mark-Iii 452 M1022s.S. Hexagonal Bolt M-6X25mm Long. 453 M1023basic Rate Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-2, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Ecommended For Use With Cylinder Assembly Suitable For Bore Well Dia 100 To 125Mm Casing Pipe. 454 M1024basic Rate Of Upvc Pipe 125Mm Dia Conforming To I.S.I. Latest Revision Is 12818 / 2016 Cml No. 5543459 455 M1025basic Rate Of 32Mm G.I. Pipe In 3 Mtrs. Length ( Medium ) With Seamless Socket As Per Relevent B.I.S. Specificationis 1239 ( Part-I ) / 2004 456 M1030rcc Esr 457 Designing ( Aesthetically ) , And Constructing Rcc Elevated Service Reservoirs Of Following Capacity With Rcc Staging Consisting Of Columns, Internal And External Bracings Spaced Vertically Not More Than 4.5 Metres Centre To Centre For Esr Having Capacity Upto 500 Cum And Not More Than 6M C / C For Esr Having Capacity Above 500 Cum Including Excavation In All Types Of Strata, Foundation Concrete, Cement Plaster With Water Proofing Compound To The In Side And Out Side Face Of The Container And Also Plaster With Plastic Paint In All Columns And Bracingsincluding Refilling Disposing Off The Surplus Stuff With In A Lead Of 50 Metres, All Labour And Material Charges Including Lowering, Laying, Erecting, Hoisting And Jointing Of Pipe Assembly Of Inlet, Outlet, Washout, Overflow And Bypass Arrangements As Per Departmental Design, Providing And Fixing Accessories Such As M.S. Ladder Out Side, Stainless Steel Lader In Contenor, C.I. Manhole Frame And Covers, Water Level Indicators, Lightening Conductor, G.I. Pipe Railing Around Walk Way And Top Slab, Providing Stair Case From Ground Level To Roof Level, M.S. Grill Gate Of 2M Height With Locking Arrangement Of Approved Design, B.B. Masonry Chambers For All Valves, Ventilating Shafts, Providing And Applying Three Coats Of Acrylie Emulsion With Silicon Edditives Paint To The Structure Incluingroof Slab, Epoxy Painting To Internal Surface And Anti-Termite Treatment For Under Ground Part Soft He Structure And Giving Satisfactory Water Tightness Test As Per I.S. Code. The Job To Include Painting Then Ame Of The Scheme And Other Details On Thereservoir As Per The Directions Of Engineer In - Charge. 458 Notes 459 The Design Of The Structure Be In Accordance With Relevant I.S. Specification ( I.S. 3370 - 1965 Or Revised. ) 460 The Design Shall Satisfy The Stipulations As Per I.S. 1893 -1984 And I.S.13920 / 1993 For Seismic Force And I.S.-11682 / 1985 For R.C.C. Staging Of Over Head Tanks. 461 For Design Having More Than 6 Columns, Suitable Bracing Is Obligatory. 462 Plain Round Mild Steel Bars Grade- I Conforming To I.S.432 Part-I Orhigh Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S. 1139 Shall Beused, Grade- I Imildsteel Bars Will Not Be Allowed 463 Irrespective Of The Type Of Foundation Proposed In The Design, One Set Of Bracing Be Provided At The Ground Level. 464 These Rates Include Providing M.S. Ladder For E.S.R.S Upto 2 Lakh Litres Capacity And Providing Spiral Stair Case For E.S.R. Above 2 Lakh Litres Capacity. 465 Staging Shall Have To Bede Signed With Stresses Of M-200 Concrete For Esr. However All Rcc Construction Should Be Donein M-250. Structures In Contact With Water Shall Be Designed & Casted In M-300 466 These Rates Are Including The Cost Of Up Lift Pressure If Any And Entire Dewatering During Execution. Incase Of Water Logging Are A Where Water Is Struck At Shallow Depth, Extra Provision Of Dewatering Shall Be Made As Per Site Condition. 467 All Conditions Given In The Member SecretaryS Circular No. Mjp / Ts-I / 350 / 1668 Dt. 2-8-97 And Mjp / S-I / 350 / 2127 Dt. 13-7-99 Shall Be Strictly Followed And Additional Cost, If Any, Due To These Conditions Is Included In The Rates Mentioned Below. 468 75 % Part Rate Shall Be Payable For Reinforcement Concrete And Plastering Items Of Containers Of E.S.R. Till Satisfactory Hydraulic Testing For Water Tightness Is Given; And Till That Work Shall Be Treated As Incomplete. 469 The Rates Indicated In The Table Are Excluding The Cost Of Pipes, Specials And Valves Required For Inlet, Outlet, Washout, Overflow And Bypass Arrangement. The Scope Of Work, However, Includes Cost Of Erecting, Laying And Jointing Of Pipe And Valves Including Cost Of Jointing Materials Upto 5 M Beyond Outer Face Of Outer Most Column ( Cost Of Pipe, Specials And Valves Is Taken As 10% Of The Cost Of Esr As Per Table ) . 470 For Esr Upto 500 Cum Capacity C.I. Double Flanged Pipes Upto 300 Mm Dia Shall Be Provided And C.I. Specials Shall Be Used. For Esr Above 500 Cum Capacity C.I. / M.S. Pipe Assembly With Minimum 8 Mm Thickness Upto 500 Mm Dia And Minimum 10 Mm Thickness Above 500 Mm Dia Can Be Used With Proper Anti-Corrosive Epoxy Treatment From In Side And Out Side. 471 Below Mentioned Rates Are For Foundation Swith Individual Footing With Bearing Capacity Of 20 Tonnes Per Square Metre. For Raft Foundations, These Rates Shall Be Increased By 7.5% Where Safe Bearing Capacity ( Sbc ) Is 5 Mt Per Sqm And By 5 % Where Sbc Is More Than 5Mt / Sqm And Upto 10 Mt / Sqm. This % Of5 % Or 7. 5 % Is Applicable For Estimation Of Amount Of Lumpsum Item Of Esr. For Extra Item Due To Change From Individual Foundation To Raft, Actual Increase In Concrete And Steel Be Paid As Per Relevant Dsr Item. 472 The Rate Shall Be Increased By 30 % For Bearing Piles Upto Depth Of 10 M And For Further Increased In Depth By 5 M Each, It Shall Be Increased By Another 10%. These Rates Are Applicable Where Raft Is Not Feasible. For Pile Foundations Sulphate Resistant Cement Shall Only Beused. Single Pile For The Column Is Not Permitted, Group Of Piles Shall Be Designed With Pile Cap For Each Column Of Esr. 473 The Rates Are Applicable For Staging Height Of 12 M. These Rates Shall Be Increased Or Decreased For Per Metre Variation In This Staging Height As Below : 474 12 To 16 M Staging - 2% Per Metre 475 16 To 20 M Staging - 3% Per Metre 476 20 M And Above - 4% Per Metre 477 For 17 M Staging Height, Percentage Calculation Will Be Like Below : 478 12 To 16 M --- 4 X 2 = 8% 479 16 & 17 M --- 1 X 3% = 3% Total = 11% 480 For 21 M Staging Height, Percentage Calculation Will Be Like Below : 481 12 To 16 M --- 4 X 2 = 8% 482 16 To 20 M --- 4 X 3% = 12% 483 20& 21 M --- 1 X 4% = 4% Total = 24% 484 Following Rates Are For Seismic Zone Iii. For Zone Iv, These Rates Shall Be Increased By 5% And For Zone Ii, These Rates Shall Be Decreased By 5%. Concerned Executive Engineer Shall Confirm The Seismic Zone For The Scheme From Seismic Zone Splan Before Estimation And Adopt Appropriate Rates As Per Actual Seismic Zones. ( Seismic Maps Attached In This Csr ) . 485 Notes 486 Conditions From Sr.No.1 To 10 Shall Form A Part And Parcel Of The Tender And Must Be Included In The Draft Tender Papers For Works Of R.C.C. E.S.R. 487 Conditions From Sr.No.11 To 16 Are For Estimation Purpose Only And Shall Not Appear In The Tender. 488 Rates For Rcc Esrs 489 Upto 25, 000 Litres 490 Cost Of 25, 000 Litres Capacity 491 Add For Capacity Above 25, 000 Upto 50, 000 Litres 492 Cost Of 50, 000 Litres Capacity 493 Add For Capacity Above 50, 000 Upto 75, 000 Litres 494 Cost Of 75, 000 Litres Capacity 495 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 496 Cost Of 1, 00, 000 Litres Capacity 497 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 498 Cost Of 1, 50, 000 Litres Capacity 499 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 500 Cost Of 2, 00, 000 Litres Capacity 501 Add For Capacity Above 2, 00, 000 Upto 2, 50, 000 Litres 502 Cost Of 2, 50, 000 Litres Capacity 503 Add For Capacity Above 2, 50, 000 Upto 3, 00, 000 Litres 504 Cost Of 3, 00, 000 Litres Capacity 505 Add For Capacity Above 3, 00, 000 Upto 4, 00, 000 Litres 506 Cost Of 4, 00, 000 Litres Capacity 507 Add For Capacity Above 4, 00, 000 Upto 5, 00, 000 Litres 508 Cost Of 5, 00, 000 Litres Capacity 509 Add For Capacity Above 5, 00, 000 Upto 7, 50, 000 Litres 510 Cost Of 7, 50, 000 Litres Capacity 511 Add For Capacity Above 7, 50, 000 Upto 10, 00, 000 Litres 512 Cost Of 10, 00, 000 Litres Capacity 513 Add For Capacity Above 10, 00, 000 Upto 15, 00, 000 Litres 514 Cost Of 15, 00, 000 Litres Capacity 515 Add For Capacity Above 15, 00, 000 Upto 20, 00, 000 Litres 516 Cost Of 20, 00, 000 Litres Capacity 517 M1031rcc Gsr And Sump 518 Designing ( Aesthetically ) , And Constructing Rcc Ground Service Reservoirs / Rcc Sumps In M-300 Mix. Of Required Capacity Including Excavation In All Types Of Strata, Foundation Concrete, Container Walls, Bottom Slab Top Rcc Roof Slab / Or Dome, 20 Mm Thick Cement Plaster With Water Proofing Compound In Cm 1:3 Proportion. To Inside Face Of The Container, Including Epoxy Paint From Inside Including Refilling And Disposing Of Surplus Stuff Within Lead Of 50 M, All Labour And Material Charges, For Laying And Jointing Of Pipe Assembly For Inlet, Outlet Washout, Over Flow And Bye-Pass Arrangement Consisting Of C.I. / M.S. D / F. Pipes, Specials And Valves Of Given Diameters, Providing And Fixing Accessories Such As M.S. Ladder Inside And Outside, C.I. Manhole Frame And Cover, Water Top Slab, B.B. Masonry Chamber For All Valves, Ventilating Shafts, Including Giving Satisfactory Hydraulic Test And Water Tightness Test As Per Is Code And Providing Three Coat Of Cement Paints To All Expose Surface Of Structure Including Roof Surface Etc. Complete As Per Design Data, Criteria, Obligatory Requirements And Detailed Specifications. 519 Anti –Termite Treatment Shall Be Given For Under Ground Portion Of The Structure. 520 Notes 521 The Design Shall Be In Accordance With Various Relevant I.S. Specification ( I.S.456 / 2000, I.S.875-1987, I.S.3370-1965 Or Revised. ) 522 Only M.S. Bars Grade I Conforming To I.S. 432 Part-I Or High Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S.1139 Shall Be Used.Grade- Ii M.S. Bars Shall Not Be Used. 523 Entire Structure Shall Be In M-300 Only. 524 The Scope Of Pipe Assembly Work Shall Be Upto 5 Metre Beyond Out Side Face Of The Wall, Cost Of Pipes Valves And Specials Is Not Included In The Rate But Labour Cost For Laying And Jointing Is Included. 525 The G.S.R. / Sump Above 15 Lakh Litres Capacity Shall Be In Two Compartment. 526 The Job Includes Designing The Structure For Up Lift Pressure And Dewatering If Required During Entire Execution And Disposal Of Surplus Excavated Stuff Within Lead Of 50 Metres As Directed By Engineer-In-Charge. If Up Lifts Considered In Design, Then These Rates Shall Be Increased By 7.5%. 527 G.S.R. Outlets Shall Be With Bell Mouth Of Approved Pattern In Bottom Slab And Cost Of Designing Bell Mouth Is Included In The Rate. Sump Well Includes Cost Of Suction Pit Required At Bottom. 528 For Pipe Diameters Upto 300Mm Only Cipipes And Ci Specials Shall Be Used. For Pipe Diameters Above 300Mm, M.S. Pipes And Specials Minimum 10Mm Thick Shall Be Used With Proper Anti Corrosive Epoxy Treatment From Inside And Outside. 529 Cost Of Pump House Is Not Included In These Rates. 530 Above Rates Are Applicable For Seismic Zones 2, 3 And 4. 531 75% Part Rate Shall Be Payable For Reinforcement, Concrete And Plastering Items Of All Types Of G.S.R. Sand Sump Still Satisfactory Hydraulic Testing For Water Tightness Test Is Given And Till That Work Shall Be Treated As Incomplete. 532 10% Shall Be Added For Sump If Over Head Pump House Is Proposed. 533 Note: Conditions From Sr.No.1 To 11 Shall Form A Part And Parcel Of Tender And Must Be Included In The Draft Tender Papers For Work Of R.C.C .Gsrs And Sumps. 534 Rates For Rcc Gsrs And Sumps 535 Upto 25, 000 Litres 536 Cost Of 25, 000 Litres Capacity 537 Add For Capacity Above 25, 000 Upto 50, 000 Litres 538 Cost Of 50, 000 Litres Capacity 539 Add For Capacity Above 50, 000 Upto 75, 000 Litres 540 Cost Of 75, 000 Litres Capacity 541 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 542 Cost Of 1, 00, 000 Litres Capacity 543 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 544 Cost Of 1, 50, 000 Litres Capacity 545 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 546 Cost Of 2, 00, 000 Litres Capacity 547 Add For Capacity Above 2, 00, 000 Upto 3, 00, 000 Litres 548 Cost Of 3, 00, 000 Litres Capacity 549 Add For Capacity Above 3, 00, 000 Upto 5, 00, 000 Litres 550 Cost Of 5, 00, 000 Litres Capacity 551 Add For Capacity Above 5, 00, 000 Upto 10, 00, 000 Litres 552 Cost Of 10, 00, 000 Litres Capacity 553 Addforcapacityabove10, 00, 000Upto15, 00, 000 Litres 554 Cost Of 15, 00, 000 Litres Capacity 555 Add For Capacity Above 15, 00, 000 Litres 556 Note: 10% Shall Be Added Over The Cost Of Gsr For Sump Where Over Head Pump House Is Proposed. 557 M1032unconventionalwater Treatment Plant 558 Designing ( Aesthetically ) , Providing And Constructinghigh Rate Unconventionalwatertreatmentplant I.E. Simplified Water Treatment Plant Consisting Of Civil Works Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti-Termitetreatmenttoentirestructurebelowgroundlevel, Ceramic Tiles For Floring, Acrylic Emulsion With Silicon Additives Paint From Outside Stainless Steel Railing, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow : Includingnecessaryhydraulic Testing, Structuraltesting And Trial For 3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) Works. 559 Aeration Fountain 560 Inlet Arrangements 561 Mixing Channel With Ventury Flume And Flow Measuring Arrangement 562 Inlet Channel 563 Flocculator- Conforming To I.S. 7208-1974 ( Type-C ) With Detention Period Of 30 Minutes 564 Tube Settlers-Designing, Fabricating And Constructing Tube Settlers With Square Or Any Other Shaped Tube Like Circular, Cheveron, Hexagonal Etc .Having Proven Performance 565 Rapid Sand Gravity Filters - All Valve Shall Be Glandless. 566 Filter House 567 Chemical House 568 Alum Tanks- 2Nos. With Mixing, Carrying And Dosing Arrangements With Piping. 569 100 Kg Chlorine Cylender For Capacity Upto 5Mld And Chlorine Tonner For Capacity Above 5 Mld. 570 Tcl Solution Tank With Mixing, Carrying And Dosing Arrangement With Piping. 571 Bypass Arrangement 572 External And Internal Electrification 573 Laboratory Equipments 574 Wash Water Tanks Of Capacity Equal To12 Minutes To Wash Specified Number Of Filter Beds At Time At 600 Lit / M2 / M Under Head Of 12M At Under Drain. 575 Wash Water Pumps With 100% Standby 576 Air Blowers Capable Of Delivering 600 Lmp Per Square Metre Of Free Air Of Filter Area At 0.4 Kg / Sqcm At The Under Drains ( 100 % Standby ) .Air Blowers Shall Be Adopted For Wtp Having Capacity More Than 3 Mld Only. Below 3 Mld Capacity, Air Blowers Shall Not Be Adopted. 577 Pure Water Sump Of Capacity Equal To 1 Hourpumping Capacity. 578 Pure Water Pump House Over The Sump / By The Side Of Sump. 579 Drainage Arrangements 580 Alum Store 581 Sanitary Block With Necessary Water Supply And Drainage Arrangements And Internalwbm Roads. 582 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 583 Rates Given Below Are Inclusive Of Uplift Pressure If Any And Dewatering During The Entire Work. 584 All Rcc Structures Shall Be Constructed In M-250. Structures In Contact With Water Shall Be In M-300. 585 Unconventional Treatment Plants Less Than 1 Mld Capacity Shall Not Be Constructed. 586 All The Structural Steel Works / Fabrications Are To Be Provided With Application Of Hot Dip Zinc Coating According To Specification As Per Is 4759:1996 ( Reafirmed 2006 ) . 587 Note: Conditions From Sr. No. 1 To 28 Shall Form A Part And Parcel Of The Tender And Must Be Included In Draft Tender Papers For The Work Of Unconventional Treatment Plants. 588 Unconventional Water Treatment Plant 589 Fixed Cost For 1 Mld 590 Add For Capacity Above 1 Mld Upto 2 Mld 591 Cost Of 2 Mld Treatment Plant 592 Add For Capacity Above 2 Mld Upto 3 Mld 593 Cost Of 3 Mld Treatment Plant 594 M1033conventionalwater Treatment Plant 595 Designing ( Aesthetically ) , Providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, Mechanicalandelectricalworks Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow, Includingnecessaryhydraulic Testing, Structuraltesting, Equipmenttestingandtrialrunfora Periodof3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) . 596 Aeration Fountain- Plan Are A Not Less Than 0.625 Square Metre Per Mld 597 Ventury Flume - With Necessary Devices, Consisting Of Simple Mechanical Indicator. ( Pedestal Type Gauge ) 598 Flash Mixer-Rapid Mixing Device, Detention Time 60 Seconds To Give Velocity Gradient 300 To 400 Sec -1, Vane Mixer Type Conforming To I.S. 7090 Of 1985. 599 Flocculator – Conforming To I.S.7208-1974 ( Type-C ) With Detention Period Of 30 Minutes. 600 Clarifier - Horizontal Flow Circular Tank, Detention Period 2-5 Hours, Overflow Rate 30 Cubic Metre Per Square Metre Per Day ( To Be Specified ) , Weir Loading Not More Than 300 Cubic Metre Per Metre Per Day, With Mechanical Sludge Scraper Conforming To I.S. No. 10313-1982. 601 Rapid Sand Filter Sand Filter House-Filter Designed For Filteration Rate Of 5, 000 Litres Per Square Metre Per Hour, Minimum 2 Beds For Plant Upto 10 Mld, For Larger Plants As Specified, Filters To Be Located In Filter House With Roof Slab, Pipe Gallery And Platform Minimum 5.5 Metre In Width. 602 Filtersand-Effective Size 0.45 To 0.70Mm, Uniformity Coefficient Not More Than 1.7, Nor Less Than 1.3, Depth Of Water Over Sand 0.75M, Free Board 50Cm, Gravel 0.45M In Depth, Sand And Gravel Conforming To I.S. 8491 ( I ) -77, Back Wash By Air Wash, Stand Ard Appurtenances ( To Be Specified ) , Rate Of Flow Controller, Filter Gauge, Sand Expansion Gauge, Etc. 603 Wash Water Tank-Capacity To Be Specified And Suitable To Supply Water To Wash 2 Filter Units At A Time Where The Units Are 4 Or More. 604 Wash Water Pumps- Capacity To Fill Water Tank In 1 Hour With 100% Standby. 605 Air Blowers-Capable Of Delivering 600 Lmp Per Square Metre Of Free Air, Of Filter Area At 0.4Kg / Sqcm At The Under Drains ( 100% Standby ) . 606 Chemical House In Two Storeys 607 Ground Floor To Accommodate 7 Days Alum Requirement And Sundry Storage. 608 First Floor To Accommodate Alum And Lime Tanks.Etc. 609 Solution Tanks-Minimum 3 Tanks ( One For Preparation, Second For Dosing And Third As Standby ) , Each Tank Capable Of Giving 8 Hours Maximum Dose Without Interruption, Minimum Free Board 0.30M, Trays For Dissolving, Level Indicator, Mechanical Agitation Devices, Solution Feed And Drain Lines, Solution Feed Device ( Constant Head Device, Strength Of Solution Upto 10% Only ) Conforming To I.S. 9222 Part-I 1979. 610 Pure Water Sump And Sump House. 611 Capacity Of Sump – One Hour Of Designed Flow. 612 Pump House- Pump House Of Required Size Over The Sump Or By The Side. 613 Store House-Suitable For Alum Storage Of Three Months Requirement In Monsoon With 10% Extra Capacity For Other Sundry Articles. 614 Vacuum Feed Type Chlorinators- Make Tobe Approved By Mjp. 615 Conforming To I.S. 10533 - A Part-Ii 1983 616 Rate For Withdrawal 617 Temperature Kg. Of Chlorine Discharge Degree C Per Day ( Cylinders ) 618 45 67Tonnes 619 10 6.359.50 110 620 15 10.75 16.10130 621 20 14.50 21.24254 622 27&Above18.70 28.12315 623 Chlorinator Equipment And Container Room To Conform To I.S. 10553 Part-I 1983. 624 100% Standby Shall Be Provided. 625 By Pass Arrangements - C.I. Or M.S. Pipes. 626 Disposal Of Waste From Wtp: Safe Disposal Arrangement To Near By Nala Including Cost Of Pipe 627 For Wtp Of Capacity 30 Mld And More Additional Arrangement For Backwash Water Recycle Shall Be Provided, Including Sump, Pupming Machinary, Rising Main Etc Complete 628 Drainage Arrangements – Rcc Pipes Up To Plot Boundary. 629 Electrical Installation – Both Internal And External Including Entire Plant Area. 630 Laboratory Equipment –As Per Requirement ( To Be Specified During Tendering ) . 631 Sanitary Blocks – Carpet Area -15 Square Metre Minimum Upto 25 Mld And 25 Square Metre Above 25 Mld. 632 Administrative Block And Internal Road-To Accommodate Office Room, Chlorine Room, Laboratory Room, Panel Board Room, Blower Room Etc. And Wbm Road To Connect All Units From Main Gate Of Plot. 633 Rates Given Below Are Inclusive Of Up Lift Pressure If Any And Dewatering During Entire Work. 634 All Pipes Condutes Channels With20%Overloading 635 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 636 All Rcc Structures Shall Be Constructed In M-300. 637 Note: Conditions From Sr. No. 1 To 22 Shall Form A Part And Parcel Of The Tender And Must Be Incorporated In Draft Tender Papers Of Conventional Treatment Plants ( Proposed ) . 638 Conventional Water Treatment Plant 639 Above3 Mld To Upto 5 Mld 640 Cost Of 5 Mld Treatment Plant 641 Add For Capacity Above 5Mld Upto 10 Mld 642 Cost Of 10 Mld Treatment Plant 643 Add For Capacity Above 10 Mld Upto20 Mld 644 Cost Of 20 Mld Treatment Plant 645 Add For Capacity Above 20 Mld Upto 50 Mld 646 Cost Of 50 Mld Treatment Plant 647 Add For Capacityabove 50 Mld Upto 100 Mld 648 Cost Of 100 Mld Treatment Plant 649 Add For Capacity Above 100 Mld 650 M1034gpt / Hygpt :Drilling By Rotary Drill Machine Of Size 300Mm & 400Mm Dia With T.C. Drill Bit For Tubewells In All Kinds Of Soil Including Moorum, Hard Soil, Soil Mixed With Pebbles, Shingles, Compacted Soil, Clay, Soft And Decomposed Rock Etc, Up To 60 Meters Depth Including Reaming To Facilitate Smooth Lowering Of Casing Pipe Etc. As Per Specification And Direction Of E / I ( Basic Rates ) 651 300 Mm Dia For Gpt 652 400 Mm Dia For Hygpt 653 M1035hydt : Cost Of Drilling 200 Mm X 165 Mm X 125 Meter Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site ( Basic Rates ) 654 From 0-50 Meter 655 From 51-125 Meter 656 M1037dt :Basic Rates For 125 / 115 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil And Rock For Installation Of Hand Pump With Dth Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant, For Making 125 / 115 Mm Dia Boring Etc. And Cost Of Transporting Rig Machine And Other Vehicle Up To Site Of Work As Per Specification And Dirrection Of Engineer Incharge ( Basic Rates ) 657 Drillig Upto 30 Mtr Depth Below G. L. In Rural Area 658 Drilling Beyond 31 Mtr Upto 60 Mtr Below G. L. In Rural Area 659 M1038trenchless 660 Installation Of Product Pipe By Manual Pipe Jacking Method Including Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Manual Shielded Excation , Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 661 From 900 Mm To 1000 Mm Dia 662 In Soft Soil 663 In Hard Soil 664 In Sandy Soil 665 In Stone Soil 666 From 1000 Mm To 1200 Mm Dia 667 In Soft Soil 668 In Hard Soil 669 In Sandy Soil 670 In Stone Soil 671 Above 1200 Mm To 1500 Mm Dia 672 In Soft Soil 673 In Hard Soil 674 In Sandy Soil 675 In Stone Soil 676 Installation Of Product Pipe By Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 677 Upto 300 Mm Dia 678 In Soft Soil 679 In Hard Soil 680 In Sandy Soil 681 In Stone Soil 682 Above300 Mm To 450 Mm Dia 683 In Soft Soil 684 In Hard Soil 685 In Sandy Soil 686 In Stone Soil 687 Above 450 Mm To 600 Mm Dia 688 In Soft Soil 689 In Hard Soil 690 In Sandy Soil 691 In Stone Soil 692 Above 600 Mm To 900 Mm Dia 693 In Soft Soil 694 In Hard Soil 695 In Sandy Soil 696 In Stone Soil 697 Installation Of Product Pipe By Guided Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 698 Upto 300 Mm Dia 699 In Soft Soil 700 In Hard Soil 701 In Sandy Soil 702 In Stone Soil 703 Above300 Mm To 450 Mm Dia 704 In Soft Soil 705 In Hard Soil 706 In Sandy Soil 707 In Stone Soil 708 Above 450 Mm To 600 Mm Dia 709 In Soft Soil 710 In Hard Soil 711 In Sandy Soil 712 In Stone Soil 713 Above 600 Mm To 900 Mm Dia 714 In Soft Soil 715 In Hard Soil 716 In Sandy Soil 717 In Stone Soil 718 M1039providing And Supplying Isi Mark Ci / D / F Reflux Valves ( Non Return Valves ) Of Following Dia Inspection Charges Unloading From Railway Wagon , Loading Into Truck Transportation Upto Department Stores / Site Unloading Stacking Etc. Complete Reflux Valve As Per Is 5312 Part I ( 1984 ) 719 Without Byepass Arrangement - Pn-1 720 50 Mm 721 65 Mm 722 80 Mm 723 100 Mm 724 125 Mm 725 150 Mm 726 200 Mm 727 250 Mm 728 300 Mm 729 350 Mm 730 400 Mm 731 450 Mm 732 500 Mm 733 600 Mm 734 700 Mm 735 750 Mm 736 800 Mm 737 900 Mm 738 1000 Mm 739 1100 Mm 740 1200 Mm 741 With Byepass Arrangement - Pn-1 742 50 Mm 743 65 Mm 744 80 Mm 745 100 Mm 746 125 Mm 747 150 Mm 748 200 Mm 749 250 Mm 750 300 Mm 751 350 Mm 752 400 Mm 753 450 Mm 754 500 Mm 755 600 Mm 756 700 Mm 757 750 Mm 758 800 Mm 759 900 Mm 760 1000 Mm 761 1100 Mm 762 1200 Mm 763 Without Byepass Arrangement - Pn-1.6 764 50 Mm 765 65 Mm 766 80 Mm 767 100 Mm 768 125 Mm 769 150 Mm 770 200 Mm 771 250 Mm 772 300 Mm 773 350 Mm 774 400 Mm 775 450 Mm 776 500 Mm 777 600 Mm 778 With Byepass Arrangement - Pn-1.6 779 50 Mm 780 65 Mm 781 80 Mm 782 100 Mm 783 125 Mm 784 150 Mm 785 200 Mm 786 250 Mm 787 300 Mm 788 350 Mm 789 400 Mm 790 450 Mm 791 500 Mm 792 600 Mm 793 Providing Double Flange Sluice Valve ( Size 50 Mm To 1200 Mm ) Confirming For Is - 2906 / 14846 Including Worn Gear Arrangements As Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete . 794 With Byepass Arrangement - Pn-1 795 50 Mm 796 65 Mm 797 80 Mm 798 100 Mm 799 125 Mm 800 150 Mm 801 200 Mm 802 250 Mm 803 300 Mm 804 350 Mm 805 400 Mm 806 450 Mm 807 500 Mm 808 600 Mm 809 700Mm 810 750 Mm 811 800 Mm 812 900 Mm 813 1000 Mm 814 1100 Mm 815 1200Mm 816 Without Byepass Arrangement - Pn-1 817 50 Mm 818 65 Mm 819 80 Mm 820 100 Mm 821 125 Mm 822 150 Mm 823 200 Mm 824 250 Mm 825 300 Mm 826 350 Mm 827 400 Mm 828 450 Mm 829 500 Mm 830 600 Mm 831 700Mm 832 750 Mm 833 800 Mm 834 900 Mm 835 1000 Mm 836 1100 Mm 837 1200Mm 838 Providing Double Flange Sluice Valve Confirming For Is - 2906 / 14846 Including Worn Gearas Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete For Rateincluding All Taxes . . 839 Without Byepass Arrangement - Pn-1.6 840 50 Mm 841 65 Mm 842 80 Mm 843 100 Mm 844 125 Mm 845 150 Mm 846 200 Mm 847 250 Mm 848 300 Mm 849 350 Mm 850 400 Mm 851 450 Mm 852 500 Mm 853 600 Mm 854 700Mm 855 750 Mm 856 800 Mm 857 900 Mm 858 1000 Mm 859 1100 Mm 860 1200Mm 861 With Byepass Arrangement - Pn-1.6 862 50 Mm 863 65 Mm 864 80 Mm 865 100 Mm 866 125 Mm 867 150 Mm 868 200 Mm 869 250 Mm 870 300 Mm 871 350 Mm 872 400 Mm 873 450 Mm 874 500 Mm 875 600 Mm 876 M1040design And Supply Of V -Wire Screen Laterals Suitable For Infiltration Galleryas Per Site Condition And Detail Provided End Connection Suitable Flange Excluding Taxes And Transportation . 877 Dia - 06 Inch ( 150 Mm ) 878 Id - 153 Mm Od -167 Mm 879 Screen Thickness - 07 Mm 880 Slot - 1.00 Mm 881 Moc - Lowcarbon Galvenised Steel 882 Length - 5 Mtr. 883 Dia - 08 Inch ( 200 Mm ) 884 Id - 205 Mm Od -221Mm 885 Screen Thickness - 08 Mm 886 Slot - 1.00 Mm 887 Moc - Lowcarbon Galvenised Steel 888 Length - 5 Mtr. 889 Dia - 10 Inch ( 250 Mm ) 890 Id - 256 Mm Od -276Mm 891 Screen Thickness - 10 Mm 892 Slot - 1.00 Mm 893 Moc - Lowcarbon Galvenised Steel 894 Length - 5 Mtr. 895 Dia - 12 Inch ( 300 Mm ) 896 Id - 306 Mm Od -326 Mm 897 Screen Thickness - 10 Mm 898 Slot - 1.00 Mm 899 Moc - Lowcarbon Galvenised Steel 900 Length - 5 Mtr. 901 Dia - 14 Inch ( 350 Mm ) 902 Id - 338 Mm Od -363 Mm 903 Screen Thickness - 12.5 Mm 904 Slot - 1.00 Mm 905 Moc - Lowcarbon Galvenised Steel 906 Length - 5 Mtr. 907 M1041supplying All Materials, Labours, Equipments For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Sides From Falling During The Process Of Drilling All Complete Including Carriage Of Materials To Work Site ( Basic Rate ) . 908 M1042supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Dirction E / I ( Basic Rate ) . 909 M1043supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting The Casing Pipe After Lowering In The Bore Including Carriage Of Materials To Work Site Etc. All Complete As Per Specification & Direction Of E / I ( Basic Rate ) . 910 M1044supplying Labour And Equipments Including 125Mm Dia G.I. Cap And Fitting And Fixing Over The Casing Pipe Of Tube Well Properly And Taking It Out As Per Direction E / I ( The Cap Will Be The Property Of Department ) ( Basic Rate ) . 911 M1045supplying All Materials, Labours, Equipments For Constructing P.C.C. ( 1:2:4 ) Circular Platform Around Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design, Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 912 M1046supplying All Materials, Labours And Equipments For Constructing P.C.C. ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 913 M1047supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly & Connecting Rod ( 12 Pcs ) As Per Is : 15500 Part-2 / 2004 ( Basic Rate ) . 914 M1048supply Of 200Mm Dia X 3.00M Long Upvc Casing Pipe Conferming To Is : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 915 M1049supply Of 200Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 916 M1050supply Of 125Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 917 M1051supplying All Tools, Equipments And Labour And Lowering 32 Mm Dia Medium Quality G.I. Pipe In Drilled Tube Well In 3 Mtrs. Length All Complete As Per Dirction E / I Including Carriage Of Materials ( Basic Rate ) . 918 M1052supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod Complete Job As Per Specification & Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 919 M1053supplying All Materials, Labours And Fixing India Mark Ii Hand Pump With All Accessories All Complete Job As Per Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 920 M1054design, Supply, Installation Testing & Commissioning Of Packaged Water Treatment Plants ( Unconventional Type ) Of Different Capacity With ( 20 Hours Operation ) Comprising Of Lamella Clarifier, Static Mixture Flocculation Tank ( Smet ) , Multi Grade Filter ( Mgf ) With Best Quality Filter Media, Lime / Coagulant / Polymer Dosing System Hypo Chloride Dosing System, Raw Water Feed Pump / Clear Water Transfer Pump ( Either Or ) , Sludge Transfer Cum Recirculation Pump, Filter Feed Pump & Back Wash Pump Including All Fitting Like Valve And Other Special Fittings And Electrical Power Supply To The Different Supplied Units With Mcb Panel Internal Electrification With Lighting Arrangement With Treatment Plant Site With Provision Of Chemical Storage And Water Testing Boratoryfacility Should Be From A Reputed Manufacturer / Authorized Distribution / Authorized Dealer Conforming To Relevant Is Codes And Certified By Iso-9001-2008 & 14001, It Also Include Cost Of Civil Foundation, Including Clarified Water Tank Internal Connecting Pipe Line From Raw Water Inlet To Cwr And Applying Internal Epoxy Paint On The Supply Equipment All The Prices Are Exclusive Of Gst, Allied Structure / Items Which Are Site Specific Such As External Electrification, Approach Road, Foot Bridge, Cofferdam, Compound Wall, Scada And Automation, Cwr Pumps Etc Are To Be Considered Extra. 921 0.2 Mld 922 0.3 Mld 923 0.4 Mld 924 0.5 Mld 925 0.6 Mld 926 M1055pumps 927 Supplying100 Mm Dia Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene / Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon / Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single / Double Run Shall Be Provided With Each Pump. 928 Submersible Pump Set 100 Mm Dia ( With Polypropylene / Noryl Impeller ) Up To 20 Stages 929 1 H.P. 930 1.5Hp 931 2 Hp 932 2.5 Hp 933 3.0 Hp 934 4.0 Hp 935 5.0 Hp 936 Supply Rate Should Be Increased By Rs 200 / - Per Stage For Pump With More Than 20 Stages 937 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 8 Stages 938 1.5 Hp 939 2.0 Hp 940 3.0 Hp 941 4.0 Hp 942 5.0 Hp 943 6.0 Hp 944 7.5 Hp 945 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 8 Stages 946 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 12 Stages 947 8.0 Hp 948 9.0 Hp 949 10.0 Hp 950 11.0 Hp 951 12.5 Hp 952 15.0 Hp 953 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 12 Stages 954 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 20 Stages 955 17.5 Hp 956 20.0 Hp 957 25 Hp 958 1 ) Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 20 Stages For Bore Well Only. 959 For Other Use 200 Mm Dia Pump Shall Be Preferred Over 150 Mm Dia With More Than 20 Stage Pump. 960 2 ) For 150 Mm Dia Energy Efficient Pumps Add As Below 961 A. Up To 8 Stages :- 3% On Supply Rate 962 B. Up To 12 Stages :- 4% On Supply Rate 963 C. Up To 15 Stages :- 5% On Supply Rate 964 M1056pressure Gauge 965 Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint 966 Pressure Gauge ( 100 Mm Dia ) 967 Pressure Gauge ( 150 Mm Dia ) 968 Vacuum / Combination Gauge 969 Supplyingvacuum Gauge / Combination Gauge Of Required Range Complete With Syphon Tube, Isolating Cock Suitable For 12 Mm Dia G.I. Pipe. 970 Vacuum / Combination Gauge – 100 Mm Dia 971 Vacuum / Combination Gauge – 150 Mm Dia 972 M1057lifting Equipment 973 Chain Pulley Block 974 Supplyingtriple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 975 1 Tonne Capacity 976 2 Tonne Capacity 977 3 Tonne Capacity 978 Hand Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 979 Supplyingsingle Girder Hand Operated Circular / Rectangular Travelling Crane With 6 M Lift Complete With Chain Pulley Block Isi Marked And Travelling Trolley Both Tested For 50% Overload Including Arrangement For Longitudinal Travel / Circular Travel And Cross Travel With Wheel, Hand Chain, Etc Complete. 980 3 Tonne Capacity 981 Up To 5 M Span 982 Above 5 M Up To 6 M Span 983 Above 6 M Up To 8 M Span 984 5 Tonne Capacity 985 Up To 5 M Span 986 Above 5 M Up To 6 M Span 987 Above 6 M Up To 8 M Span 988 Above 8 M Up To 10 M Span 989 Electric Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 990 Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. 991 5 Tonne Capacity 992 Above 6 M Up To 8 M Span 993 Above 8 M Up To 10 M Span 994 7.5 Tonne Capacity 995 Above 6 M Upto 8 M Span 996 Above 8 M Up To 10 M Span 997 10 Tonne Capacity 998 Above 6 M Up To 8 M Span 999 Above 8 M Up To 10 M Span 1000 Square Bar / Rail 1001 Providing, Erecting And Fixing Square Bar Of En 8 As Rail For Over Head Crane On Provided Track, Girder / Continuous Corbel Beam, Including Supporting Plate And “J” Bolts. 1002 50 X 50 Mm ( En 8 ) 1003 40 X 40 Mm ( En 8 ) 1004 M1058lightening Arrester, Ab Switch, Insulators 1005 Lightening Arrestor 1006 Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. 1007 Suitable For 11 Kv Supply, Distribution Class 1008 Suitable For 22 Kv Supply, Distribution Class 1009 Suitable For 33 Kv Supply, Station Class 1010 Disc Insulator 1011 Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1012 Suitable For 11Kv Line 1013 Suitable For 33Kv Line 1014 Pin Insulator 1015 Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1016 Suitable For 11Kv Line 1017 Suitable For 33Kv Line 1018 Air Break Switch Without Earth Switch 1019 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1020 Suitable For 11Kv Line 1021 Rocking / Tilting Type 1022 Rotating Type 1023 Suitable For 33Kv Line 1024 Rocking / Tilting Type 1025 Rotating Type 1026 Air Break Switch With Earth Switch 1027 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1028 Suitable For 11Kv Line 1029 Rotating Type 1030 Suitable For 33Kv Line 1031 Rotating Type 1032 Drop Out Fuse ( Channel Mounted ) 1033 Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Currentup To 50 Amp, Capacity Completeerected On Provided Cross Arm, Each Set Comprising 3 Units 1034 Suitable For 11 Kv Line 1035 Suitable For 33 Kv Line 1036 Horn Gap Fuse ( Channel Mounted ) 1037 Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units 1038 Suitable For 11 Kv Line 1039 Suitable For 33 Kv Line 1040 M1059transformer 1041 Power Transformer ( With Off Load Tap Changer ) Any Isi Mark 1042 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1043 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1044 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1045 3. Oil Drain Valve 1046 4. Oil Filter Valve 1047 5. Lifting Eyes / Hooks 1048 6. Two Earthing Terminals 1049 7. Diagram And Rating Plate 1050 8. Air Vent 1051 9. Explosion Vent 1052 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1053 11. Four Bi Directional Plain Roller. 1054 Power Transformer 11000 / 433 Volts With Off Load Tap Changer – 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. 1055 63 Kva ( No Load Loss 180W And Load Loss 1235W ) 1056 100 Kva ( No Load Loss 260W And Load Loss 1760W ) 1057 160Kva ( No Load Loss 260W And Load Loss 1760W ) 1058 200Kva ( No Load Loss 500W And Load Loss3000w ) 1059 250Kvaa ( No Load Loss 550W And Load Loss3600w ) 1060 315Kva ( No Load Loss 580W And Load Loss 4200W ) 1061 400 Kva ( No Load Loss 715W And Load Loss 5000W ) 1062 500 Kva ( No Load Loss 850W And Load Loss 5800W ) 1063 630 Kva ( No Load Loss 1000W And Load Loss 7000W ) 1064 750 Kva ( No Load Loss 1500W And Load Loss 8000W ) 1065 Power Transformer ( With On Load Tap Changer ) 1066 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1067 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1068 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1069 3. Oil Drain Valve 1070 4. Oil Filter Valve 1071 5. Lifting Eyes / Hooks 1072 6. Two Earthing Terminals 1073 7. Diagram And Rating Plate 1074 8. Air Vent 1075 9. Explosion Vent 1076 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1077 11. Four Bi Directional Plain Roller. 1078 12. Buchholz Relay 1079 13. Resistance Temp. Detector 1080 14. Marshalling Box 1081 15. Automatic Voltage Regulator ( Avr ) 1082 16. Remote Tap Changing Controller ( Rtcc ) 1083 Transformer 11000 / 433 Volts Withon Load Tap Changer – 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification As Per Bis Level-2. 1084 750 Kva 1085 1000 Kva 1086 1250 Kva 1087 1600 Kva 1088 2000 Kva 1089 M1060motors 1090 Foot Mounted Motors Tefc 1500 Rpm 1091 Supplyingfoot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts + / -10%, 3 Phase, 50 Hz + / -3% With “F” Class Insulation Temperature Rise Limited To Class “B” Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. 1092 15 Kw ( 20 Hp ) 1093 18.5 Kw ( 25 Hp ) 1094 22 Kw ( 30 Hp ) 1095 30 Kw ( 40 Hp ) 1096 37 Kw ( 50 Hp ) 1097 45 Kw ( 60 Hp ) 1098 55 Kw ( 75 Hp ) 1099 75 Kw ( 100 Hp ) 1100 90 Kw ( 120 Hp ) 1101 110 Kw ( 150 Hp ) 1102 132Kw ( 180Hp ) 1103 160Kw ( 215 Hp ) 1104 250Kw ( 335 Hp ) 1105 Foot Mounted Motor Tefc 1500 Rpm 1106 0.75 Kw ( 1Hp ) 1107 1.1 Kw ( 1.5 Hp ) 1108 1.5 Kw ( 2 Hp ) 1109 2.2 Kw ( 3 Hp ) 1110 3.7 Kw ( 5 Hp ) 1111 5.5 Kw ( 7.5 Hp ) 1112 7.5 Kw ( 10 Hp ) 1113 9.3 Kw ( 12.5 Hp ) 1114 11 Kw ( 15 Hp ) 1115 M1061aluminium Cable 1116 Cable 1117 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1118 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1119 3 Core 2.5 Sq Mm 1120 3 Core 4 Sq Mm 1121 3 Core 6 Sq Mm 1122 3 Core 10 Sq Mm 1123 3 Core 16 Sq Mm 1124 3 Core 25 Sq Mm 1125 3 Core 35 Sq Mm 1126 3 Core 50 Sq Mm 1127 3 Core 70 Sq Mm 1128 3 Core 95 Sq Mm 1129 3 Core 120 Sq Mm 1130 3 Core 150 Sq Mm 1131 3 Core 185 Sq Mm 1132 3 Core 240 Sq Mm 1133 3 Core 300 Sq Mm 1134 3 Core 400 Sq Mm 1135 Aluminium Conductor 3.5 Core, Xlpe / Pvc Insulated & Unarmoured Cable 1136 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three And Half Core, Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1137 3.5 Core 25 Sq Mm 1138 3.5 Core 35 Sq Mm 1139 3.5 Core 50 Sq Mm 1140 3.5 Core 70 Sq Mm 1141 3.5 Core 95 Sq Mm 1142 3.5 Core 120 Sq Mm 1143 3.5 Core 150 Sq Mm 1144 3.5 Core 185 Sq Mm 1145 3.5 Core 240 Sq Mm 1146 3.5 Core 300 Sq Mm 1147 3.5 Core 400 Sq Mm 1148 Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated 1149 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1150 3 Core 35 Sq Mm 1151 3 Core 50 Sq Mm 1152 3 Core 70 Sq Mm 1153 3 Core 95 Sq Mm 1154 3 Core 120 Sq Mm 1155 3 Core150sq Mm 1156 3 Core 185 Sq Mm 1157 3 Core 240Sq Mm 1158 3 Core 300 Sq Mm 1159 3 Core 400 Sq Mm 1160 Ht Aluminium Three Core 6.6 Kv ( Ue ) / 11Kv Ecable Xlpe Insulated 1161 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1162 3 Core 35 Sq Mm 1163 3 Core 50 Sq Mm 1164 3 Core 70 Sq Mm 1165 3 Core 95 Sq Mm 1166 3 Core 120 Sq Mm 1167 3 Core150sq Mm 1168 3 Core 185 Sq Mm 1169 3 Core 240Sq Mm 1170 3 Core 300 Sq Mm 1171 3 Core 400 Sq Mm 1172 Ht Aluminium Three Core 11Kv ( Ue ) Cable Xlpe Insulated 1173 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1174 3 Core 35 Sq Mm 1175 3 Core 50 Sq Mm 1176 3 Core 70 Sq Mm 1177 3 Core 95 Sq Mm 1178 3 Core 120 Sq Mm 1179 3 Core150sq Mm 1180 3 Core 185 Sq Mm 1181 3 Core 240Sq Mm 1182 3 Core 300 Sq Mm 1183 3 Core 400 Sq Mm 1184 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1185 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1186 3 Core 4 Sq Mm 1187 3 Core 6 Sq Mm 1188 3 Core 10 Sq Mm 1189 3 Core 16 Sq Mm 1190 3 Core 25 Sq Mm 1191 3 Core 35 Sq Mm 1192 3 Core 50 Sq Mm 1193 3 Core 70 Sq Mm 1194 3 Core 95 Sq Mm 1195 3 Core 120 Sq Mm 1196 3 Core 150 Sq Mm 1197 3 Core 185 Sq Mm 1198 3 Core 240 Sq Mm 1199 3 Core 300 Sq Mm 1200 3 Core 400 Sq Mm 1201 M1062copper Cable 1202 Cable 1203 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . 1204 Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . 1205 3 Core 1.5 Sq Mm 1206 3 Core 2.5 Sq Mm 1207 3 Core 4 Sq Mm 1208 3 Core 6 Sq Mm 1209 3 Core 10 Sq Mm 1210 3 Core 16 Sq Mm 1211 3 Core 25 Sq Mm 1212 3 Core 35 Sq Mm 1213 Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1214 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1215 3 Core 1.5 Sq Mm 1216 3 Core 2.5 Sq Mm 1217 3 Core 4 Sq Mm 1218 3 Core 6 Sq Mm 1219 3 Core 10 Sq Mm 1220 3 Core 16 Sq Mm 1221 3 Core 25 Sq Mm 1222 3 Core 35 Sq Mm 1223 3 Core 50 Sq Mm 1224 3 Core 70 Sq Mm 1225 3 Core 95 Sq Mm 1226 Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . 1227 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1228 3.5 Core 1.5 Sq Mm 1229 3.5 Core 2.5 Sq Mm 1230 3.5 Core 4 Sq Mm 1231 3.5 Core 6 Sq Mm 1232 3.5 Core 10 Sq Mm 1233 3.5 Core 16 Sq Mm 1234 3.5 Core 25 Sq Mm 1235 3.5 Core 35 Sq Mm 1236 3.5 Core 50 Sq Mm 1237 3 .5 Core 70 Sq Mm 1238 3.5 Core 95 Sq Mm 1239 3.5 Core 120 Sq Mm 1240 3 .5 Core150sq Mm 1241 3.5 Core 185 Sq Mm 1242 3.5 Core 240Sq Mm 1243 3.5 Core 300 Sq Mm 1244 3.5 Core 400 Sq Mm 1245 Copper Conductor 3.5 Core Xlpe / Pvcunarmoured 1246 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1247 3.5Core 25 Sq Mm 1248 3.5Core 35 Sq Mm 1249 3.5 Core 50 Sq Mm 1250 3.5 Core 70 Sq Mm 1251 3.5 Core 95 Sq Mm 1252 3.5 Core 120 Sq Mm 1253 3.5 Core150sq Mm 1254 3.5 Core 185 Sq Mm 1255 3.5 Core 240Sq Mm 1256 3.5 Core 300 Sq Mm 1257 3.5 Core 400 Sq Mm 1258 Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1259 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1260 3 Core 1.5 Sq Mm 1261 3 Core 2.5 Sq Mm 1262 3 Core 4 Sq Mm 1263 3 Core 6 Sq Mm 1264 3 Core 10 Sq Mm 1265 3 Core 16 Sq Mm 1266 3 Core 25 Sq Mm 1267 3 Core 35 Sq Mm 1268 3 Core 50 Sq Mm 1269 3 Core 70 Sq Mm 1270 3 Core 95 Sq Mm 1271 3 Core 120 Sq Mm 1272 3 Core 150Sq Mm 1273 3Core 185 Sq Mm 1274 3 Core 240 Sq Mm 1275 3 Core 300 Sq Mm 1276 3 Core 400 Sq Mm 1277 M1063foot Valve 1278 Foot Valve 1279 Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. 1280 Flanged Type 1281 50 Mm 1282 65 Mm 1283 80 Mm 1284 100 Mm 1285 125 Mm 1286 150 Mm 1287 M1064aircircuit Breaker 1288 Acbbreaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole 1289 630A 1290 800A 1291 1000A 1292 1250A 1293 1600A 1294 2000A 1295 M1065starter 1296 D.O.L. Starter With Ss Enclosure With 380 / 415 Volt Coil 1297 7.5 H.P. 1298 10 H.P. 1299 Supplyingfully Automatic Star Delta Starter To Operate Induction Motor Working On415v, 3Phase, 50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser 1300 F.A.S.D Starter 1301 10.0 H.P. 1302 15 H.P. 1303 20 H.P. 1304 25 H.P. 1305 35 H.P. 1306 40 Hp 1307 50 Hp 1308 75 H.P. 1309 100 H.P. 1310 125 H.P. 1311 150 H.P. 1312 250 H.P. 1313 M1066servo Controlled Automatic Voltage Stabilizer 1314 Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt + / -1%, 3 Ph, 50 Hz, With Copper Wound Transformer ( Air / Oil Cooled ) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And UserS Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto / Manual Selector Switch, Raise / Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated?? Over Voltage / Under Voltage?? Single Phasing?? Cut Off Contactor With Electronic Output Sensing Unit 1315 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 150 To 450 Volt 1316 20 Kva Air Cooled 1317 25 Kva Air Cooled 1318 30 Kva Air Cooled 1319 40 Kva Air Cooled 1320 50 Kva Oil Cooled 1321 60 Kva Oil Cooled 1322 75 Kva Oil Cooled 1323 100 Kva Oil Cooled 1324 125 Kva Oil Cooled 1325 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 280 To 460 Volt 1326 15 Kva Air Cooled 1327 20 Kva Air Cooled 1328 25 Kva Air Cooled 1329 30 Kva Air Cooled 1330 40 Kva Air Cooled 1331 50Kva Air Cooled 1332 60 Kva Oil Cooled 1333 75Kva Oil Cooled 1334 100 Kva Oil Cooled 1335 125 Kva Oil Cooled 1336 150 Kva Oil Cooled 1337 200Kva Oil Cooled 1338 250Kva Oil Cooled 1339 300 Kva Oil Cooled 1340 400 Kva Oil Cooled 1341 M1067termination Kit 1342 Providing And Errecting In-Door Type Termination Kit, For 3.3Kv / 6.6 Kv / 11Kv / 22Kv / 33Kv Xlpe Screened 3 Core Cable 1343 In-Door Termination Kit For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1344 25-50 Mm2 1345 70-120 Mm2 1346 150-185 Mm2 1347 240-400 Mm2 1348 Out-Door Termination Kit For 3.3 ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1349 25-50 Mm2 1350 70-120 Mm2 1351 150-185 Mm2 1352 240-400 Mm2 1353 Straight Through Joint For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1354 25-50 Mm2 1355 70-120 Mm2 1356 150-185 Mm2 1357 240-300 Mm2 1358 In Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1359 25-50 Mm2 1360 70-120 Mm2 1361 150-185 Mm2 1362 240-400 Mm2 1363 Out Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1364 25-50 Mm2 1365 70-120 Mm2 1366 150-185 Mm2 1367 240-400 Mm2 1368 Straight Through Joint For 11 Kv ( E ) Xlpe Screened 3 Core Cable 1369 25-50 Mm2 1370 70-120 Mm2 1371 150-185 Mm2 1372 240-300 Mm2 1373 In Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1374 25-50 Mm2 1375 70-120 Mm2 1376 150-185 Mm2 1377 240-400 Mm2 1378 Out Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1379 25-50 Mm2 1380 70-120 Mm2 1381 150-185 Mm2 1382 240-400 Mm2 1383 Straight Through Joint For 22 Kv ( E ) Xlpe Screened 3 Core Cable 1384 25-50 Mm2 1385 70-95 Mm2 1386 120-150 Mm2 1387 185-240 Mm2 1388 300-400 Mm2 1389 In Door Termination Kit For 33Kv ( E ) Xlpe Screened 3 Core Cable 1390 25-50 Mm2 1391 70-95 Mm2 1392 120-185 Mm2 1393 240-400 Mm2 1394 Out Door Termination Kit For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1395 25-50 Mm2 1396 70-95 Mm2 1397 120-185 Mm2 1398 240-400 Mm2 1399 Straight Through Joint For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1400 35-70 Mm2 1401 95-150 Mm2 1402 185-300 Mm2 1403 400 Mm2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
40.
Educational and Research Institute #8811347 Technical Bid
Supply Of Equipment-1.01 Ohm’S Laws Apparatus With In Built Power Supply 1.02 Kirchoffs Law Apparatus 1.03 Superposition Theorem Apparatus. 1.04 Thevenin’S And Norton’S Theorem Apparatus 1.05 Maximum Power Transfer Theorem Apparatus 1.06 Connection And Measurement Of Power Consumption Of Various Lamps. 1.07 Experement : Hartley Oscillator 1.08 V-I Characteristics Of Incandescent Lamps And Time Fusing Current Characteristics Of A Fuse. 1.09 Calculation Of Current, Voltage And Power In Series R-L-C Circuit Excited By Single Phase Ac Supply And Calculation Of Power Factor. 1.10 Verifying B-H Curve Of An Electromagnet. 2 Network Theory Lab 2.01 To Observe A.C. Wave Form On C.R.O. And Calculates Average & R.M.S. Values, Frequency, And Observe The Response Of Resistance To Ac 2.02 Experement :- Study Of Lead & Leg Network In Ac Circuits To Observe Response Of Inductor And Capacitor To Ac 2.03 Experement :-Calculation Of Impedance In Ac Circuit To Determine Impedance & Plot The Phasor Diagram Of R-L Series Circuit. 2.04 Experement :-Calculation Of Power & Power Factor In Rc Ac Circuit To Determine The Current And P.F. Of R.C. Series Circuit. 2.05 Experement :-Calculation Of Power & Power Factor In Rlc Ac Circuit To Determine The Current And P.F. In R.L.C. Series Circuit. 2.06 Experement :-Rlc Series Resonance With Inbuilt Sine Wave Oscillator 2.07 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator 2.08 Experement :- Calculation Of Power & Power Factor In Rc Ac Circuit 2.09 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator To Determine The Current. In R.L.C. Parallel Circuit. 2.10 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator To Obtain Resonance In R-L-C Parallel Circuit. 2.11 Experement :- Measurement Of Power In Balanced Load Using Two Watt Meter Method In Three Phase Circuit. To Verify The Line And Phase Values For Star Connected Balanced Load. 2.12 Experiment :- Study Of Voltage & Current Relationship In Three Phase Circuits. 2.13 Superposition Theorem Apparatus. 2.14 Thevenin’S And Norton’S Theorem Trainer 2.15 Maximum Power Transfer Theorem Apparatus With Three Power Supplies. 3 Electronics Lab 3.01 Forward & Reverse Characteristics Of Pn Junction Diode 3.02 Characteristics Of Zener Diode 3.03 Study Of Rectifiers ( Half Wave & Full Wave ) & Filters ( Capacitor & Inductor Filter ) 3.04 Input & Output Characteristics Of Transistor In Ce Mode 3.05 Characteristics Of Fet 3.06 Characteristics Of Ujt 3.07 Load & Line Regulation Characteristics Of Regulator 3.08 Frequency Response Of Single Stage Rc Coupled Amplifier. 3.09 To Study The V-I Characteristics Of Pn Junction Diode. 3.10 Determination Of H Parameter. 3.11 To Verify The Truth Table Of Logic Gates Realize And, Or, Not Gates. 3.12 To Realize And, Or Gates Using Diodes And Resistors. 3.13 To Verify The Boolean Algebra Function Using Digital Ic Gates ( Consensus Theorem ) . 3.14 To Realize The Function F ( A, B, C, D ) = ( C+D ) ( A+B ) ( B+D ) Neither Using Nor Gates. 3.15 Design A Half / Full Adder Circuit Using Logic Gates. 3.16 Design A Half / Full Subtractor Circuit Using Logic Gates. 3.17 Design A Binary To Gray Code Converter. 3.18 Design A Function Using K-Map And Verify Its Performance Using Sop & Pos. 3.19 Design Bcd To Seven Segment Display Using 7447 Ic. 3.20 Experiment :- Study Of 4 Bit & 16 Bit Multiplexer 3.21 To Study 8085 Based Microprocessor System 3.22 To Load Content In One Register And Shift It To Another. 3.23 To Move The Content Of One Memory Location To Another. 3.24 To Develop And Run A Program For Finding Out The Largest / Smallest Number From A Given Set Of Numbers. 3.25 To Develop And Run A Program For Arranging In Ascending / Descending Order Of A Set Of Number 3.26 To Perform Multiplication / Division Of Given Numbers. 3.27 To Perform Floating Point Mathematical Operations ( Addition, Subtraction, Multiplication, And Division ) . 3.28 To Perform Computation Of Square Root Of A Given Number. 4 Instrumentation System Lab / Electronics Measurements 4.01 To Determine Output Characteristic Of A Lvdt And Determine Its Sensitivity. 4.02 Study Characteristics Of Temperature Transducer Like Thermocouple, Thermister And Rtd With Implementation Of Small Project Using Signal Conditioning Circuit. 4.03 Study Characteristics Of Light Transducer Like Photovoltaic Cell, Phototransistor And Photodiode With Implementation Of Small Project Using Signal Conditioning Circuit. 4.04 To Study Input- Output Characteristics Of A Potentiometer And Use Of Two Potentiometers As An Error Detector. 4.05 Adc Converter 4.06 Dac Converter 4.07 Measurement Of Passive Elements R , L And C Using Bridge Networks 4.08 Study Of Transducers And Characterization-Power Electronics Lab- 5.01 Study Of Voltage – Current Characteristics Of Thyristor 5.02 Study Of Full Wave Rectifier Using Scr 5.03 Study Of Parallel Inverter Using Scr. 5.04 Study Of Bridge Rectifier Using Scr 5.05 Study Of Series Inverter Using Scr. 5.06 Study Of Chopper Using Scr 5.07 Study Of Circuit Breaker Using Scr 5.08 Study Of Battery Charger Using Scr 5.09 Speed Control Of Dc Series Motor 6.01 Measurement Of Current And Voltages By Low Range Ammeter And Voltmeter Respectively With Shunt And Multiplier. 6.02 Calibration Of Wattmeter At Various Power Factors By Standard Wattmeter 6.03 Measurement Of Power In Three Phase Circuits Measurement Of Active Power In Three Phase Balanced Load By Single Wattmeter Method. 6.04 Measurement Of Power In Three Phase Circuits Using Two Watt Meters. 6.05 Measurement Of Power In Three Phase Circuits Using Voltmeters & Ammeters. Measurement Of Three-Phase Power With 3 Ammeters And 3 Voltmeters. 6.06 Calibration Of Energy Meter At Various Power Factors By Standard Energy Meter. 6.07 Measurement Of Energy In Single Phase & Three Phase Balanced Load Using Electronic Energy Meter. 6.08 Measurement Of Low Resistance By Kelvins Double Bridge. 6.09 Measurement Of Medium Resistance By Wheatstone Bridge 6.10 Measurement Of Resistance, Voltage, Current, Voltage, Current In A.C & D. C. Circuit By Using Digital Multimeter. 6.11 To Measure Linear Displacement By Lvdt And Plot Characteristics. 6.12 Measurement Of Inductance By Maxwell Bridge 6.13 Measurement Of Capacitance By Schering Bridge 6.14 Measurement Of Inductance By Hay Bridge 7 Digitalcommunication 7.01 Observe Waveforms Of Pulse Amplitude Modulation ( Using Natural Sampling & Flat Top Sampling ) . 7.02 Observe Waveforms Of Pulse Width Modulation 7.03 Observe Waveforms Of Pulse Position Modulation. 7.04 Observe Waveforms Of Pulse Code Modulation And Demodulation. 7.05 Observe Waveforms Of Ask Modulation & Demodulation. 7.06 Observe Waveforms Of Fsk Modulation & Demodulation. 7.07 Observe Waveforms Of Psk Modulation & Demodulation. 7.08 Observe Wave Forms Of Qpsk Modulation & Demodulation. 7.09 Observe Wave Forms Of Qam Modulation & Demodulation. 8 Communication System 8.01 Observe Am The Am Signal On Spectrum Analyzer 8.02 Observe Fm Wave & Calculate Modulation Index. 8.03 Am Radio Receiver. 8.04 Voltage Wave Form Analysis At Various Points In Am Receiver 8.05 Observe Input & Output Waveforms Of Am Detector. 8.05 Observe Input & Output Waveforms Of Am Detector. 8.06 Plot Graph Of Sensitivity Of Receiver. 8.07 Plot Graph Of Selectivity Of Receiver. 8.08 Plot Graph Off Fidelity Of Receiver 8.09 Fault Finding Of Am Radio Receiver. 8.10 Fm Detector Characteristics. 8.11 Measure The Length Of Directors, Reflectors, Dipoles And Spacing Between The Yagi Uda Antenna Andc Compare With The Theoretical Value. 9 Control System Lab 9.01 Transfer Function Of First And Second Order System 9.02 Sensors System Control System Study M Lab Platform. 01 9.03 Ac Position Servo System Study 9.04 Dc Position Servo System Study 9.05 Control Through Magnetic Amplifier 9.06 Measurement Of Passive Elements R , L And C Using Bridge Networks 9.07 Study Of Transducers And Characterization 9.08 Digital Simulation Of Linear Systems 9.09 Stability Analysis Of Linear System Using Matlab Or Equivalent Software 9.10 Study The Effect Of P, Pt, Pid Controllers Using Matlab Or Equivalent Software Or Witl Conventional Methods. 10 Strength Of Material Lab 10.01 Young’S Modulus Apparatus 10.02 Torsion Of Steel Beam Apparatus 10.03 Flexure Testing Machine 100Kn Digital 10.04 Euler’S Load Buckling Testing Machine 11 Surveying Lab 11.01 Optical Square 11.02 To Verify Law Of Polygon Of Forces 11.03 Digital Tachometer 11.04 Digital Planimeter 12 Building Materials Lab 12.01 Vickers Hardness Tester 12.02 Mortar Mixer Automatic / Manual 12.03 Concrete Mixer With Cube Mould 13 Geo-Technical Engineering Lab 13.01 Sand Replacement Method 13.02 Laboratory Permeability Apparatus -Falling Head & Constant Head 13.03 Standard Compaction Test App. 14 Hydraulics Lab 14.01 Channel Section Having Sudden Change In Slope For The Formation Of Hydraulic Jump Or Hydraulic Jump Apparatus ( Tilting Flume Apparatus ) 2.5 Meter 14.02 Pitot Tube Apparatus 14.03 Reynolds Apparatus To Study The Types Of Flow 14.04 Determine The Darcy’S Law Apparatus 14.05 Hydraulic Ram Apparatus 14.06 Apparatus To Determine Orifice And Mouthpiece 14.07 Current Water Meter Apparatus 14.08 Dead Weight Pressure Gauge Tester 14.09 Venturimeter Test Rig 14.10 Orificemeter Test Rig 14.11 Francis Turbine Test Rig 14.12 Kaplan Turbine Test Rig 14.13 Bernoulli’S Apparatus 14.14 Losses In Pipe And Fitting Apparatus 14.15 Closed Circuit Pipe Friction Apparatusfriction Losses In Pipe 14.16 Centrifugal Pump Test Rig 14.17 Reciprocating Pump Test Rig. 14.18 Pelton Wheel Test Rig 15 Transportation Engineering Lab 15.01 Aggregate Impact Tester 15.02 Softening Point Of Bitumen 15.03 Flash & Fire Point Of Bitumen 15.04 Penetration Test On Bitumen 15.05 Bankleman Beam Method 16 Laboratory Test For Highway Material: 16.01 Marshall Stability Test Apparatus 17 Advance Surveying Lab 17.01 Stadia Tachometer 17.02 Gps Survey 18 Environmental Engineering Lab 18.01 Bod Test Analyzer 18.02 Cod Test Analyzer 19 Advance Structure Lab ( Elective-Ii ) 19.01 Three Hinged Arch Apparatus 19.02 Three Bar Pin Jointed Truss 19.03 Betti’S Theorem / Elastic Properties Of Deflected Beam Apparatus 19.04 Maxwell Reciprocal Theorem Apparatus 19.05 Begg’S Deformeter Set Apparatus 19.06 Suspension Load Apparatus 19.07 Cantilever Beam 19.08 Portal Frame Apparatus 19.09 Redundant Frame Joint Apparatus 19.10 Behaviour Of Column & Struts Apparatus 19.11 Deflection Of Truss Apparatus 19.12 Two Hinged Arch Apparatus 19.13 Shear Force, Loading & Bending Moment Apparatus 20 Industrial Fluid Power Lab 20.01 Demonstrator Ofmeter In And Meter Out Circuit. 20.02 Demonstrator Of Design, Prepare & Operate Of Sequencing Circuit. 20.03 Demonstrator Of Hydraulic Circuit For Shaper Machine. 20.04 Demonstrator Of Pneumatic Circuit For Speed Control Of Double Acting Cylinders. 20.05 Demonstrator Of Pneumatic Circuit For Speed Control Of Pneumatic Motor 21 Theory Of Machine Lab 21.01 To Find The Ratio Of Time Of Cutting Stroke To The Time Of Return Stroke For Quick Return Mechanism Of A Shaper Machine 21.02 Sketch & Describe Working Of Bicycle Free Wheel Sprocket Mechanism. 21.03 Determination Of Power Transmitted By Any Belt Drive Using Any One Dynamometer. 21.04 Balancing Of Several Masses Rotating In A Single Plane By Graphical Method. 22 Thermal Engineering Lab 22.01 Study Of Solar Water Heating System. 22.02 Trace The Flue Gas Path And Water-Steam Circuit With The Help Of Boiler Model And Write Are Port. 22.03 Determination Of Change In Velocity Of Steam With Steam Nozzle. 23 Engineering Mechanics Lab 23.01 To Verify Force Transmitted By Members Of Truss 23.02 Find Ma, Vr, Efficiency, Ideal Effort, Effort Lost In Friction For Various Loads Andestablish Law Of Machine And Calculate Maximum Efficiency Of Differential Axle Andwheel 24 Automobile Engineering Lab 24.01 Universal Joint. 24.02 Battery And Function Of Charger. 24.03 Study Of Ignition System
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
41.
Housing Urban and Rular Development #8768148 AOC
Providing, Supplying, Commissioning Of Innovation Lab Equipments For Ghps & Ghs K. Veerapura Village In Ballari Taluk, Under 2515 Kkrdb Cmdq For The Year 2024-25. - Misc t-31, Six Axis Robotic ARM Consists of •Axis – 6 axis•64- bit ARM Cortex Processor8GB RAM64 GB Storage CapacityServo Motors with 9.6 Kg/cm Torque Payload – 200gReach – 200 mmUSB Support port Should have 8 MP Camera User can add various objects for detection Should identify pre trained Objects Should perform pick and place operation Dimension in mm(D x H): 1100 x 600 One pair of PCB and Mechanical casing should be provided 1 2 Petro robot it should consists of Should have 8 MP Camera 64 bit ARM Cortex Processor 2-D Lidar Sensor Person Recognitiobject Recognition Should consists of 4 leg armShould perform forward and reverse motion Should have rechargeable battery Should have 12 V rechargeable BatteryPower Adapter for Battery Recharge •Dimension in cm (L x W x H): 62 x 20 x 45•One pair of PCB and Mechanical casing should be provided •Tasks performed: 1. Walking2. Running3. Pushups4. Dance5. Jumping6. Sit and Stand positions7. Lane following 1 3 Line Following robo car it should consists of A Robotic car with 4 wheelsShould have 2 IR sensors Should have 4 DC motors Atmega 328P Microcontroller L298 Motor Driver for Direction and Speed control Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5 Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: Straight Weight: 250gm•One pair of PCB and Mechanical casing should be provided 1 4 Obstacle avoidance robo car it shouldconsists of Robotic Car with 4 Wheels Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8 Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 5 Voice controlled Robo Car it should consists of 1 30 Robotic Car with 4 Wheels DC motors with drivesBluetooth controllerShould perform motions by voice command Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22 mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (KgCm): 0.8Gearbox Shape: Straight Weight: 250gm •One pair of PCB and Mechanical casing should be provided 6 RC Tank Robot RC Tank Chassis Kit – 01ESP32 controllerLED Switch4 DC motors with Drive Battery 4 DC motors with drive ESP32 controllerDimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 7 AI Humaid Robot The AI Humaid robot can realize human body induction in different directions, can perform facial recognition, supports voice interaction, and can realize the function of guiding navigation and explaining. Should have obstacle avoidance algorithm, perceive the real-time changes in the surrounding environment, bypass the obstacles in the planned path, and choose the appropriate route Go forward and finally reach the target point. The robot should have a touchable high-definition display screen, which should display, video playback, product information query, map display and other functions. The robot should have an open SDK package and an open API, which can be used for development according to the application scenario, adding exclusive personality functions, and more in line with the actual application scenario. Technical specifications include a user-friendly interface, robust security measures, seamless integration, efficient performance, and scalability. Specification: Processor: Intel i5 8th Gen Motors: DC motors for smooth and precise movement.Microphone: High-sensitivity microphone for voice recognition and interaction.Speakers: High-quality speakers for audio output and ntertainment. Display: LCD display for user interaction, information visualization. Dimension in cm(L x W x H): 50 x 54 x 100 1 8.1 IoT Pack IoT Based Smart Agriculture Smart Agriculture model should include an Raspberry Pi, a 10 inch LCD display, soil moisture sensor, water pump, and relay to automate irrigation for plants. The soil moisture sensor should continuously monitor the moisture levels in the soil. When the soil is wet, the relay should remain off, preventing the pump from operating. However, when the soil moisture level drops and becomes dry, the relay should activate, turning on the water pump to irrigate the soil. The LCD display should provide real-time feedback on soil moisture levels, ensuring efficient water management and promoting healthy plant growth. Constructed with a durable plastic body for resilience, this project demonstrates the effectiveness of smart techlogy in modern agriculture, optimizing water usage and enhancing crop health while ensuring reliable performance in various environmental conditions. Microcontroller: Raspberry piSoil Moisture Sensor – Measures soil humidity levels.DHT11/DHT22 Sensor – Monitors temperature and humidity.pH Sensor – Checks soil acidity or alkalinity.LDR (Light Sensor) – Detects sunlight intensity.Rain Sensor – Detects rainfall for irrigation control.Ultrasonic Sensor – Monitors water level in tanks.Water Pump – Automated irrigation control via relay.Servo Motor – Adjusts solar panel orientation.Relay Module (5V) – Controls high-power devices.IoT Connectivity – Data transmission via WiFi/Bluetooth.Cloud Storage – Stores real-time sensor data online.Web App – Displays real-time farm conditions.Power Adapter – Powers all connected components. 1 8.2 IoT Based Home Automation The Home Automation System model should include a Raspberry Pi, MQ-2 gas 1 31 sensor, buzzer, ultrasonic sensor, servo motor, 7-inch display, DHT11 temperature sensor, and two relays to enhance home convenience and safety. The ultrasonic sensor should detect approaching objects, triggering the servo motor to automatically open the door, while the 7-inch display presents real-time temperature readings. In one room, an IR sensor should detect motion, activating the relay to turn on an LED and a fan. Additionally, when the MQ-2 sensor detects smoke in the kitchen, the buzzer should sound an alert until the smoke dissipates. The system must feature a durable plastic body for reliability and easy assembly, showcasing the seamless integration of smart techlogies to create a safer and more efficient living environment, ensuring enhanced convenience and security. Microcontroller: Raspberry Pi for central control with WiFi and Bluetooth Ram: 4GB64 bit ARM Cortex ControllerGas Detection: MQ-2 sensor to detect smoke and gas leaksAlert System: Buzzer sounds when smoke is detectedObject Detection: Ultrasonic sensor detects approaching objects for automatic door controlDoor Mechanism: Servo motor opens the door upon object detectionDisplay: 7-inch screen for real-time temperature and system statusTemperature Monitoring: DHT11 sensor measures room temperature and humidityMotion Detection: IR sensor detects movement in the room Relay Module (x2): Controls LED and fan activationLighting & Ventilation: LED and fan turn on when motion is detectedBody: Durable plastic for reliability and easy assembly 8.3 Smart Watch health parameter monitoring kit Smart Watch is an invative wearable device project, and the model should include an ESP processor, OLED display, and four push buttons to provide a range of functionalities. The watch must feature a custom-designed PCB for compactness and efficiency, along with a durable watch belt for comfortable wear. One push button should be dedicated to displaying the current time, date, and day, while ather button should provide weather information, enhancing convenience for users. The remaining two buttons should be integrated for the IoT interface, allowing interaction with various smart devices and applications. This project demonstrates the potential of combining advanced techlogy with practical design, creating a multifunctional smartwatch that caters to modern lifestyle needs, ensuring reliability and user-friendly operation. ESP Processor – Core controller for smartwatch operations. OLED Display – Displays time, date, weather, and IoT interactions. Four Push Buttons – Dedicated for time, date, weather, and IoT control. Custom-Designed PCB – Ensures compactness and efficiency. Durable Watch Belt – Provides comfort for daily wear. Time, Date, and Day Display – Activated by a dedicated button. Weather Information Display – Accessed via a separate button. IoT Integration – Controls and interacts with smart devices. Energy-Efficient Design – Optimized for long battery life. Modern & User-Friendly – Enhances convenience and usability. 1 8.4 IoT Based Smart Cam Vision Snap should consist of an advanced security system that includes facial recognition for identifying individuals, enhancing security in restricted areas. Key components include a Raspberry Pi, a camera, and a display for real-time monitoring. This system features motion detection, which triggers alerts for unauthorized movement, significantly improving surveillance capabilities. It provides real-time alerts, enabling immediate responses to potential threats, while secure connectivity ensures the protection of sensitive data. Together, these features create a robust security solution for various applications, making Vision Snap an effective tool for safeguarding premises and enhancing overall security measures. Raspberry Pi – Central processing unit for AI-based security.Camera Module – Captures real-time footage and facial recognition.Display Screen – Shows live monitoring and alerts.Facial Recognition – Identifies individuals for security access.Motion Detection – Detects unauthorized movement and triggers alerts.Real-Time Alerts – Sends tifications for immediate response.Secure Connectivity – Protects sensitive surveillance data.AI-Powered Surveillance – 1 32 Enhances monitoring efficiency.Remote Access – Allows monitoring from any location.Robust Security System – Ideal for restricted areas and premises. 9.1 Immersive Techlogy Pack VR Headset Kit Should Consist of Following Line Item VR Head Set Storage: 512GBDisplay: Each eye experiences a resolution of 2064 x 2208 pixels, delivering sharp and immersive visuals.Processor: Powered by the Snapdragon XR2 Gen 2 chipset, providing enhanced performance for demanding VR applications.Refresh Rate: Supports a 120Hz refresh rate, ensuring smooth and responsive gameplay.Memory: Equipped with 8GB of RAM to handle multitasking and complex VR environments.Mixed Reality Capabilities: Features full-color passthrough, allowing users to blend virtual and real-world elements seamlessly.Design: Utilizes pancake optics to reduce the headsets size, offering a more comfortable fit for extended use. 1 9.2 32-inch or more smart LED TV to Stream a VR applications Resolution: HD (720p)Smart Platform: Google TVFeatures: Google Play, Google Cast Built-in, HDR10, Dolby Audio, Voice Remote, Live TV Streaming 1 9.3 AA Batteries – 10 Voltage: 3.7V (Lithium-Ion)Capacity: 1800–3500 mAhChemistry Types: Alkaline, NiMH (Rechargeable), Lithium, Zinc-CarbonSize: Diameter ~14.5mm, Length ~50.5mmWeight: ~23g to 30g 1 9.4 6DoF AR-VR Educational Controller can be used as and augmented reality (AR) device. Hold virtual heart, lungs, disaurs, plants and so much more in your hand to get an engaging learning experience. AR provides students with opportunities to deepen their kwledge within several areas, including:ScienceWorking with numbersSpatial concepts Content creationReal-life environments & scenarios 1 9.5 Samsung Galaxy M15 5G or ARCore supported Devices Display: 6.5-inch Super AMOLED, 1080 x 2340 pixelsProcessor: MediaTek Dimensity 6100+, Octa-coreRAM & Storage: 4GB/6GB/8GB RAM, 28GB/256GB storage (expandable up to 1TB)Rear Cameras: 50MP (wide) + 5MP (ultra-wide) + 2MP (macro)Front Camera: 13MPBattery: 6,000mAh, 25W fast charging OS: Android 14 with One UI 6Security: Side-mounted fingerprint sensor Connectivity: 5G, NFC supportDimensions: 160.1 x 76.8 x 9.3mm, Weight : 217g 1 9.6 VR Application Content for experintial learning a) VR chemistry lab, b) VR human anatomy, c) VR tour guide, d) VR English Learning App, e) VR space exploration app, f) VR electrical simulator app, g) VR Based Lathe Machine app, h) VR Based SMD Soldering & De soldering app 1 10 Drone Kit Should Consist of Following Line Item. Drone Kit with Wi-Fi and Camera is an ideal project for enthusiasts looking to build a custom drone from the ground up. This kit typically includes essential components such as a frame, brushless motors (BLDC), electronic speed controllers (ESCs), a flight controller board (FCB), and a Wi-Fi-enabled camera for real-time video transmission. It offers the flexibility of adding a LiPo battery for power, a remote controller, and propellers for flight stability. With built-in WiFi, users can easily control and monitor the drone using a mobile app or computer, while the camera provides aerial photography and video streaming capabilities. 1 x F450 Frame 4 x 1000kv BLDC Motor 4 x ESC Motor 1 x 2-3 Cell Battery Charger1 x 2200 mAh Lipo Battery1 x Fly Sky FS-CT6B 6ch 2.4GHz Transmitter & Receiver1 x APM 2.8 Flight Controller (Without Compass) 1 11.1 Mini Makers Pack Thermo Sage Thermo Sage is a touch-free temperature monitoring system, and the model should include an ESP8266, OLED display, infrared temperature sensor, ultrasonic sensor, two LEDs, and a buzzer for efficient health monitoring. When the ultrasonic sensor detects a person within 10 cm, the infrared sensor measures their body temperature, displaying the result on the OLED screen. If the temperature is 1 33 rmal, the green LED lights up as an indication. However, if the temperature exceeds the rmal range, the red LED activates, and the buzzer sounds an alert. The design must feature a durable plastic body for reliable performance, offering a safe, contactless solution for monitoring body temperature, ideal for public health and safety applications. Microcontroller: ESP8266 for wireless connectivityDisplay: OLED screen for temperature readingsTemperature Sensor: Infrared sensor for touch-free measurementDistance Sensor: Ultrasonic sensor to detect person within 10 cmLED Indicators: Green LED for rmal temperature, red LED for high temperatureBuzzer: Alerts when temperature is above rmal rangeBody: Durable plastic for reliable performanceOne pair of PCB and Mechanical Design will be provided 11.2 Sun Quest Sun Quest model should include an Ardui Na, two LDR modules, a servomotor, a solar panel, and two LEDs to maximize energy efficiency. The LDR modules detect light intensity, enabling the system to track the sun’s position. When one LDR senses higher light intensity, the servo motor should rotate the solar panel toward that direction to optimize energy capture. The LEDs connected to the solar panel will demonstrate real-time power generation, lighting up to show how current is produced as the panel adjusts. The design must feature a durable plastic body for longevity, enhancing solar energy efficiency by dynamically following the sun’s path throughout the day. Microcontroller: Ardui Na for system controlLight Sensors: Two LDR modules for detecting light intensityActuator: Servo motor for rotating the solar panelSolar Panel: Generates and demonstrates power outputLED Indicators: Show real-time power generationBody: Durable plastic for longevity One pair of PCB and Mechanical Design will be provided 1 11.3 LightScape Lightscape model should include an Ardui Na, LDR module, IR sensor, and 6 LEDs to optimize energy usage based on environmental conditions. When the LDR detects darkness (indicating nighttime), the system should activate, keeping 3 LEDs ON for basic lighting. When the IR sensor detects movement, all 6 LEDs should turn ON for 5 seconds to enhance visibility for pedestrians or vehicles, then return to 3 LEDs ON. During daylight, when the LDR senses light, the LEDs should remain OFF to conserve energy. The design must feature a durable plastic body for reliability, providing efficient, adaptive street lighting that responds to both time of day and movement, significantly improving energy conservation and safety on the streets. Microcontroller: Ardui Na for system automationSensors: LDR for detecting light levels, IR sensor for motion detectionLEDs: 6 LEDs for adaptive street lightingLighting Control: 3 LEDs ON at night, all 6 ON when motion is detected for 5 secondsEnergy Conservation: LEDs OFF during daylight Body: Durable plastic for reliabilityOne pair of PCB and Mechanical Design will be provided 1 11.4 Navwave NavWave is a sonar-inspired object detection system, and the model should include an ESP8266, OLED display, ultrasonic sensor, and servo motor to detect and display nearby objects. The ultrasonic sensor, mounted on the servo motor, should continuously rotate from 0 to 180 degrees, scanning the surroundings for obstacles. As objects are detected, the system should display a dotted pattern on the OLED screen, similar to a submarine radar interface, providing a real-time visual representation of object proximity and location. The design must feature a durable plastic body for reliability, simulating sonar navigation and offering a dynamic way to monitor nearby obstacles through the rotating ultrasonic sensor and radar-like display. Its robust design ensures optimal performance in various environments, making it an excellent tool for obstacle detection and navigation. •Microcontroller: ESP8266 for processing and wireless capabilityDisplay: OLED screen with radar-like visual representationSensor: Ultrasonic sensor for object detectionActuator: Servo motor for 0°-180° scanning motionDetection Mechanism: Real-time scanning and obstacle mappingBody: Durable plastic for reliabilityOne pair of PCB and Mechanical 1 34 Design will be provided 12 Electronics & Hardware Kit Universal Electrical/Electronic breadboard plug and play training kit designed to perform the experiments from the basic to advance level of electrical and electronics exercises, This kit is made easy to conduct experiments by plugging in the components in to the specifically designed breadboard. Should have built-in Function generator, power supply and required meters List of components Resistors SetPotentiometers n-linear resistors VDR-, LDR-, NTC-, PTC resistors Capacitors SetTransformer 1 13.1 Experiential Skilling Lab set Electrical Booth Spec - 01 Each workstation should have dimensions of 4 ft width and 6 ft height. The material used for the workstations construction must be high-quality plywood with a thickness of at least 10mm, ensuring durability and stability. The workstation should be designed in a plus-shaped configuration, where each arm of the plus symbol represents an individual training domain. The work station should have 4 station where, Electrical installation, Plumbing and CCTV installation can be practiced All necessaries aids for this training should be provided in this work station 1 13.2 CCTV Installation kit To provide a comprehensive training setup for students to learn and practice the installation, configuration, and maintenance of CCTV systems, including cabling, DVR setup, and network integration for monitoring and recording. Dome Cameras –1 Bullet Camera-1 DVR/NVR Unit -1 Cables and AccessoriesPower Supply with adaptorsSwitch and RouterDisplay and MonitoringNetworking Tools 1 13.3 Domestic Electric Wiring Kit To provide a comprehensive training setup for students to learn and practice the installation, wiring, and maintenance of domestic Electric wiring methods, includes reading and understanding electrical drawings, Switch gears and colour coding of cables. Domestic electric wiring kit – 1 set MCB, 4P, 25ADistribution Box 3 tier 36 modules RCCB 2P 40A 30mA ACtypeMCB xC60 1P 2A C 10000A6A 1-WAY SWITCH 6A 2-way Switch6A/16A 3-Pin Socket Outlet PVC Casing-Capping, 50mmPVC CasingCapping, 25mmPVC Conduit, High density, 19mmSaddles, 19 mmPOP screwPVC Junction Box 19mm, 1 wayPVC Junction Box 19mm, 2 wayPVC Junction Box 19mm, 3 wayPVC Junction Box 19mm, 4 wayBatten Holder2- Module Box with surface plate, PVC4-Module Box, PVC8-Module Box, PVCTools – 1 set 12V Cordless Drill machinePhilip bit Spirit Level, 30 cm Steel Rule, 30 Cm Wire Stripper Heavy duty cable cutter Try square Measurement tape Mini Hack Saw frame with blades Hack Saw Frame with blades Crimping tool, tube type lugs File Set Electrician knifeAllen key set Hole saw, 22 mm Screw Driver set se plier Drill Bit Set Mini screw driver set Aluminum Stair Case, 3 step 1 13.4 Plumbing Installation Setup To equip a plumbing training lab with all necessary tools and equipment to provide students with hands-on experience in basic and advanced plumbing techniques, including pipe fitting, jointing, fixture installation, and system testing. Tools for Pipe Cutting and ShapingPipe Cutter:Hacksaw:Pipe Bender:PVC Pipe Cutting Scissors:Tools for Threading and JoiningPipe Threaded Set: Teflon Tape Dispenser:Plumbers Soldering Kit:Adhesive Application Kit: Wrenches and SpannersAdjustable Pipe Wrench:Basin Wrench:Ring Spanner Set:Testing and Measurement ToolsWater Pressure Gauge: Flow Rate Meter:Leak Detection Kit: Spirit Level:Plumbing Fixtures for Installation PracticeSink and Basin Fixtures:Faucets and Taps:Shower Unit: Drainage System ComponentsP-traps and S-traps:Wastewater Pipes:Junction Boxes: 1 14 Smart Solar Renewable Energy Kit Solar Photovoltaic Training Kit for Lab experimentsPV Module Stand: 2s. 1 35 15 SAM S-5 Missile Educational Training Kit Missile defense systems are essential for national security, airspace protection, and strategic deterrence. This will explore the working principles of the missile system, focusing on its launch mechanism, guidance techlogy, and interception capabilities. Additionally, it will analyze the applications of the model in air defense, including target tracking, threat neutralization, and military strategy. SAM S-5 Missile System should consist of the following items. Raspberry Pi x 1Camera Module x 1Lidar or Ultrasonic sensor x 1 Servo MotorsGyroscope x 1Shooter x 1Battery x 1 Battery Adapter x 1 1 16 GEO Satellite Communication Educational Training Kit Satellites play a crucial role in modern communication, navigation, weather forecasting, and scientific research. This will explore the communication and data transmission process in GEO satellites analyze the applications of GEO satellites in telecommunications, weather forecasting, and remote sensing. GEO Satellite Communication Kit should consist of the following items. Raspberry Pi x 3ESP8266 x 3ZigBee Module and adapter x 3 RF Module x 3 Temperature and Humidity Sensor x 2 Soil Moisture Sensor x 1 NPK Sensor x 1 Pressure Sensor x 2Co2 Sensor x 1Camera Module x 1Buzzer x 3 LEDsRover Model x 1Base station Model x 1Battery Battery Adapter 1 17 LUNAR PATH Explorer- Educational Rover BOT It should comes with Matt finished metal chassis. Included all sensor metal clamps, and high torque DC Johnson A grade motors. Compatible with Ardui, raspberry, etc. Easy to assemble. Assembly manual provided in the kit. All required components, sensors, and tools are provided in the kit. It should consists of following items: 12V DC 10 RPM MOTORS -2ULTRASONIC SENSORS - 3IR SENSORS - 5 WIDE TRACK WHEELS - 4WIDE TRACK BELTNUT BOLTSSPANNER TWO IN ONE SCREWDRIVER,JUMPER WIRESSG90 SERVO MOTOR -1 ON/OFF ROCKER SWITCH -2TOGGLE SWITCH - 2MOTOR WIRES 1 18 Package . 1 Atal Tinkering Lab The package should include all items As per QR/specification for Package . 1 - Atal Tinkering Lab of NITI AAYOG Electronics Development, Robotics, Internet of Things and Sensors approved by NITI AAYOG (Approved Copy of Qrs / Specification uploaded in Gem portal) Specification: Microcontrollers & Boards:Ardui U/Na/Mega (or equivalents).Raspberry Pi 3 Model B+.ESP32, de MCU.Prototyping Tools:Solderless breadboards (400 and 800 pins).Self-adhesive proto shield and FR2 A-grade materials.Hook-up wires, jumper cables (M-M, M-F, F-F), and alligator connectors.Sensors & Modules:Wide range of sensors: Humidity, temperature, motion, gas (MQ series), IR, ultrasonic, PIR, and more.RFID Reader, Bluetooth, GSM, GPS, and Wi-Fi modules.Capacitive touch, soil moisture, rain, and color recognition sensors.Displays & Actuators:16x2 LCD display with I2C interface. LED matrices, RGB LEDs, and various single-color LEDs.Motors: DC, stepper, servo, vibrating, and BO motor with driver modules.Miscellaneous Components: Resistor and capacitor kits, diodes, transistors, and ICs (LM555).Relays, motor drivers, and piezoelectric plates.Robotics, drone, and application-specific DIY kitsPower & Connectivity:USB cables, battery packs, power banks, and clips. 1 19 Package . 2 Atal Tinkering Lab – Rapid Prototyping Tools The Package should include all items As per QR/specification for Package .2 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specifications: 3D Printer Kit and tools Dedicated UPS/Power back up Filament for 3D printer Filament Storage Box Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materials 1 20 Package . 3 Atal Tinkering Lab – Mechanical, Electrical and Measurement Tools The package should include all items As per QR/specification for Package .3 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI 1 36 AAYOG Specification: Cutting Tools: Hacksaw frame with blades (standard & mini).File set, mini file set, and flexible cutting mat. Hand Tools: Pliers (4.5-inch), tweezers, ball pein hammer, claw hammer, C-clamp, spanner set, Allen key set, wrench, and wire strippers. Drilling Tools: Drill machine set with workstation.Drill bit set and vice (rmal). Screwdrivers & Soldering Tools: Precision screwdriver set, electric screwdriver set, soldering kit, and soldering helping hand. Measuring & Testing Tools: Digital multi meter, digital Vernier caliper, spirit level, measuring tape, and pen electric tester. Digital oscilloscope, adapters, telescope, DIY paper microscope Power Tools: Cordless rotary multi tool, dual-temperature heat gun, air blower, and hot glue gun.Organization & Workspace: Plastic trays, pegboard, and return measuring tools 21 Intel Core i5 - 1245U Mid Level Laptop - tebook Specification: Laptop Type: Mid LevelIntel Core i5 - 1245UOperating System (Factory PreLoaded)Window 11 HomeRAM Size (GB)16Display Size (in cm) – Diagonal: 35.56 to 38.09 (14 In to 14.99 In)Capacity of Storage Drive (in GB)512 1 22 65 Inch Display Interactive Panel with CPU Size (Diagonal): 65 or higher Panel Techlogy: IPS / VA Resolution: (Minimum) 4K (3840 x 2160) Viewing Angle (Hx V): 178*178RAM: 4 GB or higher On-board memory: 32 GB or higher Input (Minimum): 3 x HDMI, 4 x USB (Out of, which min 2xUSB3.0),1 xAudio, 1 x OPS slot, 1 x USB Type C Port Output: (Minimum) 1 x HDMI, 1 x Audio The software enables teachers to generate presentations using Al in PPT or PDF format. The teachers can select their Class, Subject, Topic and language to generate the presentations. The software supports all Indian and Global languages including English, Hindi, Marathi, Kannada, Tamil, Telugu, Gujarati, etc. Using Al, the software is able to analyse the Class and Subject and generate output accordingly. Using the Ask Me Anything tool, the teachers can search queries related to any topic and the Al is able to generate Class-wise and Subject-wise results including Images, Videos (YouTube Videos) and Explanation. Connected Classroom Software has in-built Generative Al capability to search and import filtered content relevant to Class and Subject. - images, videos, explanation for queries given by teachers in all languages. Teachers are able to import images and videos for teaching in class. The software has a text-to-speech function (for all languages) to convert text-based explanation into speech and read out loud in class. Software has Two-Way Live Conferencing Feature with education specific features Live conferencing feature also enables recording which gets directly uploaded to cloud.. Reports: Detailed reports for Attendance, Assessments, Study Material, are available for administrators to access. Administrators should be able to access to view the whiteboard saved by the teachers and monitor the usage.. Below tools and simulations are provided for enhancing the teaching-learning experience: - Graph: Demonstrating equations using 2D and 3D visualizations - Calculator: Standard and scientific - PHET simulation library with 100+ simulations across Maths, Physics, Chemistry, Biology. 1 23 2 kVA OFF LINE UPS Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 1 24 Battery 75/80 AH capacity Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 1 25 6Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 37 26 8 Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire with switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch 1 28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire without switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 1 29 1.5 mm2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 30 Fans : 48 Sweep (1200 mm) Regular model Supplying capacitor type ceiling fan complete with down rod blades, shackle, capies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 1 31 LED Down Light 15-18W Supplying of recess mounting n integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 1 32 Fall Ceiling for Invation lab to cover entire Area Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. 1 33 Floor Mat for Invation lab to Cover the entire Lab Providing and laying lileum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications 1 34 Repair and Replacement of Windows and Doors (if required) Repairing door and window frames with available wood to the required size. 1 35 Painting Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² 1 38 with paint of approved quality to give an even shade, after thoroughly rooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-ccharge. (The gloss should be 50% @ 60 degree angle with 10 years life) 36 Providing and laying Cement concrete flooring 40 mm thick with 20 mm minal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete.(P .59, SI. 9.1 PWD SR 2023-24 Volume 2) 1 37 Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification.( SI. 8.33.1 PWD SR 2023-24 Volume 2) 1 38 Polyurethane based ingle Component for Existing surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content t less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification (P .A-149, SI. 15.2 PWD SR 2023-24 Volume 1) 1 39 Model Table - Modular Table with MDF Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 1 40 Student Table - Modular Table with Particle Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to 1 39 be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 41 Trainer Table - Executive Table with Pedestal, 3 Side Storage Unit 1 42 Student Chair – Providing and supplying Unbranded wood chair/stool, already assembled Technical Specifcation Chair feature painting. Color-Other, Style Traditional. Furniture Assembly Already Assembled. Material Wood. Additional Parameters Additional Features good quality wooden arm chairs. 1 43 Trainer Chair - Revolving Chair with Synchronic tilt mechanism 1 44 Training of Teachers The Master Trainer will conduct a 2-day Training of Trainers (ToT) program for educators on effectively utilizing the Invation Lab . The training should cover hands-on learning methodologies, STEM education, and practical applications of lab tools and techlogies (P .A-48, SI. 1 PWD SR 2023-24 Volume 1)
Contract Date: Ref. Documents Contract Value : 53.34 Lakh
Government Departments No of Bidders 1
42.
Housing Urban and Rular Development #8768130 AOC
Providing, Supplying, Commissioning Of Innovation Lab Equipments For Ghs Yettinabudihal Village In Ballari Taluk, Under 2515 Kkrdb Cmdq For The Year 2024-25. -Six Axis Robotic ARM Consists of •Axis – 6 axis•64- bit ARM Cortex Processor8GB RAM64 GB Storage CapacityServo Motors with 9.6 Kg/cm Torque Payload – 200gReach – 200 mmUSB Support port Should have 8 MP Camera User can add various objects for detection Should identify pre trained Objects Should perform pick and place operation Dimension in mm(D x H): 1100 x 600 One pair of PCB and Mechanical casing should be provided 1 2 Petro robot it should consists of Should have 8 MP Camera 64 bit ARM Cortex Processor 2-D Lidar Sensor Person Recognitiobject Recognition Should consists of 4 leg armShould perform forward and reverse motion Should have rechargeable battery Should have 12 V rechargeable BatteryPower Adapter for Battery Recharge •Dimension in cm (L x W x H): 62 x 20 x 45•One pair of PCB and Mechanical casing should be provided •Tasks performed: 1. Walking2. Running3. Pushups4. Dance5. Jumping6. Sit and Stand positions7. Lane following 1 3 Line Following robo car it should consists of A Robotic car with 4 wheelsShould have 2 IR sensors Should have 4 DC motors Atmega 328P Microcontroller L298 Motor Driver for Direction and Speed control Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5 Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: Straight Weight: 250gm•One pair of PCB and Mechanical casing should be provided 1 4 Obstacle avoidance robo car it shouldconsists of Robotic Car with 4 Wheels Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8 Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 5 Voice controlled Robo Car it should consists of 1 30 Robotic Car with 4 Wheels DC motors with drivesBluetooth controllerShould perform motions by voice command Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22 mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (KgCm): 0.8Gearbox Shape: Straight Weight: 250gm •One pair of PCB and Mechanical casing should be provided 6 RC Tank Robot RC Tank Chassis Kit – 01ESP32 controllerLED Switch4 DC motors with Drive Battery 4 DC motors with drive ESP32 controllerDimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 7 AI Humaid Robot The AI Humaid robot can realize human body induction in different directions, can perform facial recognition, supports voice interaction, and can realize the function of guiding navigation and explaining. Should have obstacle avoidance algorithm, perceive the real-time changes in the surrounding environment, bypass the obstacles in the planned path, and choose the appropriate route Go forward and finally reach the target point. The robot should have a touchable high-definition display screen, which should display, video playback, product information query, map display and other functions. The robot should have an open SDK package and an open API, which can be used for development according to the application scenario, adding exclusive personality functions, and more in line with the actual application scenario. Technical specifications include a user-friendly interface, robust security measures, seamless integration, efficient performance, and scalability. Specification: Processor: Intel i5 8th Gen Motors: DC motors for smooth and precise movement.Microphone: High-sensitivity microphone for voice recognition and interaction.Speakers: High-quality speakers for audio output and ntertainment. Display: LCD display for user interaction, information visualization. Dimension in cm(L x W x H): 50 x 54 x 100 1 8.1 IoT Pack IoT Based Smart Agriculture Smart Agriculture model should include an Raspberry Pi, a 10 inch LCD display, soil moisture sensor, water pump, and relay to automate irrigation for plants. The soil moisture sensor should continuously monitor the moisture levels in the soil. When the soil is wet, the relay should remain off, preventing the pump from operating. However, when the soil moisture level drops and becomes dry, the relay should activate, turning on the water pump to irrigate the soil. The LCD display should provide real-time feedback on soil moisture levels, ensuring efficient water management and promoting healthy plant growth. Constructed with a durable plastic body for resilience, this project demonstrates the effectiveness of smart techlogy in modern agriculture, optimizing water usage and enhancing crop health while ensuring reliable performance in various environmental conditions. Microcontroller: Raspberry piSoil Moisture Sensor – Measures soil humidity levels.DHT11/DHT22 Sensor – Monitors temperature and humidity.pH Sensor – Checks soil acidity or alkalinity.LDR (Light Sensor) – Detects sunlight intensity.Rain Sensor – Detects rainfall for irrigation control.Ultrasonic Sensor – Monitors water level in tanks.Water Pump – Automated irrigation control via relay.Servo Motor – Adjusts solar panel orientation.Relay Module (5V) – Controls high-power devices.IoT Connectivity – Data transmission via WiFi/Bluetooth.Cloud Storage – Stores real-time sensor data online.Web App – Displays real-time farm conditions.Power Adapter – Powers all connected components. 1 8.2 IoT Based Home Automation The Home Automation System model should include a Raspberry Pi, MQ-2 gas 1 31 sensor, buzzer, ultrasonic sensor, servo motor, 7-inch display, DHT11 temperature sensor, and two relays to enhance home convenience and safety. The ultrasonic sensor should detect approaching objects, triggering the servo motor to automatically open the door, while the 7-inch display presents real-time temperature readings. In one room, an IR sensor should detect motion, activating the relay to turn on an LED and a fan. Additionally, when the MQ-2 sensor detects smoke in the kitchen, the buzzer should sound an alert until the smoke dissipates. The system must feature a durable plastic body for reliability and easy assembly, showcasing the seamless integration of smart techlogies to create a safer and more efficient living environment, ensuring enhanced convenience and security. Microcontroller: Raspberry Pi for central control with WiFi and Bluetooth Ram: 4GB64 bit ARM Cortex ControllerGas Detection: MQ-2 sensor to detect smoke and gas leaksAlert System: Buzzer sounds when smoke is detectedObject Detection: Ultrasonic sensor detects approaching objects for automatic door controlDoor Mechanism: Servo motor opens the door upon object detectionDisplay: 7-inch screen for real-time temperature and system statusTemperature Monitoring: DHT11 sensor measures room temperature and humidityMotion Detection: IR sensor detects movement in the room Relay Module (x2): Controls LED and fan activationLighting & Ventilation: LED and fan turn on when motion is detectedBody: Durable plastic for reliability and easy assembly 8.3 Smart Watch health parameter monitoring kit Smart Watch is an invative wearable device project, and the model should include an ESP processor, OLED display, and four push buttons to provide a range of functionalities. The watch must feature a custom-designed PCB for compactness and efficiency, along with a durable watch belt for comfortable wear. One push button should be dedicated to displaying the current time, date, and day, while ather button should provide weather information, enhancing convenience for users. The remaining two buttons should be integrated for the IoT interface, allowing interaction with various smart devices and applications. This project demonstrates the potential of combining advanced techlogy with practical design, creating a multifunctional smartwatch that caters to modern lifestyle needs, ensuring reliability and user-friendly operation. ESP Processor – Core controller for smartwatch operations. OLED Display – Displays time, date, weather, and IoT interactions. Four Push Buttons – Dedicated for time, date, weather, and IoT control. Custom-Designed PCB – Ensures compactness and efficiency. Durable Watch Belt – Provides comfort for daily wear. Time, Date, and Day Display – Activated by a dedicated button. Weather Information Display – Accessed via a separate button. IoT Integration – Controls and interacts with smart devices. Energy-Efficient Design – Optimized for long battery life. Modern & User-Friendly – Enhances convenience and usability. 1 8.4 IoT Based Smart Cam Vision Snap should consist of an advanced security system that includes facial recognition for identifying individuals, enhancing security in restricted areas. Key components include a Raspberry Pi, a camera, and a display for real-time monitoring. This system features motion detection, which triggers alerts for unauthorized movement, significantly improving surveillance capabilities. It provides real-time alerts, enabling immediate responses to potential threats, while secure connectivity ensures the protection of sensitive data. Together, these features create a robust security solution for various applications, making Vision Snap an effective tool for safeguarding premises and enhancing overall security measures. Raspberry Pi – Central processing unit for AI-based security.Camera Module – Captures real-time footage and facial recognition.Display Screen – Shows live monitoring and alerts.Facial Recognition – Identifies individuals for security access.Motion Detection – Detects unauthorized movement and triggers alerts.Real-Time Alerts – Sends tifications for immediate response.Secure Connectivity – Protects sensitive surveillance data.AI-Powered Surveillance – 1 32 Enhances monitoring efficiency.Remote Access – Allows monitoring from any location.Robust Security System – Ideal for restricted areas and premises. 9.1 Immersive Techlogy Pack VR Headset Kit Should Consist of Following Line Item VR Head Set Storage: 512GBDisplay: Each eye experiences a resolution of 2064 x 2208 pixels, delivering sharp and immersive visuals.Processor: Powered by the Snapdragon XR2 Gen 2 chipset, providing enhanced performance for demanding VR applications.Refresh Rate: Supports a 120Hz refresh rate, ensuring smooth and responsive gameplay.Memory: Equipped with 8GB of RAM to handle multitasking and complex VR environments.Mixed Reality Capabilities: Features full-color passthrough, allowing users to blend virtual and real-world elements seamlessly.Design: Utilizes pancake optics to reduce the headsets size, offering a more comfortable fit for extended use. 1 9.2 32-inch or more smart LED TV to Stream a VR applications Resolution: HD (720p)Smart Platform: Google TVFeatures: Google Play, Google Cast Built-in, HDR10, Dolby Audio, Voice Remote, Live TV Streaming 1 9.3 AA Batteries – 10 Voltage: 3.7V (Lithium-Ion)Capacity: 1800–3500 mAhChemistry Types: Alkaline, NiMH (Rechargeable), Lithium, Zinc-CarbonSize: Diameter ~14.5mm, Length ~50.5mmWeight: ~23g to 30g 1 9.4 6DoF AR-VR Educational Controller can be used as and augmented reality (AR) device. Hold virtual heart, lungs, disaurs, plants and so much more in your hand to get an engaging learning experience. AR provides students with opportunities to deepen their kwledge within several areas, including:ScienceWorking with numbersSpatial concepts Content creationReal-life environments & scenarios 1 9.5 Samsung Galaxy M15 5G or ARCore supported Devices Display: 6.5-inch Super AMOLED, 1080 x 2340 pixelsProcessor: MediaTek Dimensity 6100+, Octa-coreRAM & Storage: 4GB/6GB/8GB RAM, 28GB/256GB storage (expandable up to 1TB)Rear Cameras: 50MP (wide) + 5MP (ultra-wide) + 2MP (macro)Front Camera: 13MPBattery: 6,000mAh, 25W fast charging OS: Android 14 with One UI 6Security: Side-mounted fingerprint sensor Connectivity: 5G, NFC supportDimensions: 160.1 x 76.8 x 9.3mm, Weight : 217g 1 9.6 VR Application Content for experintial learning a) VR chemistry lab, b) VR human anatomy, c) VR tour guide, d) VR English Learning App, e) VR space exploration app, f) VR electrical simulator app, g) VR Based Lathe Machine app, h) VR Based SMD Soldering & De soldering app 1 10 Drone Kit Should Consist of Following Line Item. Drone Kit with Wi-Fi and Camera is an ideal project for enthusiasts looking to build a custom drone from the ground up. This kit typically includes essential components such as a frame, brushless motors (BLDC), electronic speed controllers (ESCs), a flight controller board (FCB), and a Wi-Fi-enabled camera for real-time video transmission. It offers the flexibility of adding a LiPo battery for power, a remote controller, and propellers for flight stability. With built-in WiFi, users can easily control and monitor the drone using a mobile app or computer, while the camera provides aerial photography and video streaming capabilities. 1 x F450 Frame 4 x 1000kv BLDC Motor 4 x ESC Motor 1 x 2-3 Cell Battery Charger1 x 2200 mAh Lipo Battery1 x Fly Sky FS-CT6B 6ch 2.4GHz Transmitter & Receiver1 x APM 2.8 Flight Controller (Without Compass) 1 11.1 Mini Makers Pack Thermo Sage Thermo Sage is a touch-free temperature monitoring system, and the model should include an ESP8266, OLED display, infrared temperature sensor, ultrasonic sensor, two LEDs, and a buzzer for efficient health monitoring. When the ultrasonic sensor detects a person within 10 cm, the infrared sensor measures their body temperature, displaying the result on the OLED screen. If the temperature is 1 33 rmal, the green LED lights up as an indication. However, if the temperature exceeds the rmal range, the red LED activates, and the buzzer sounds an alert. The design must feature a durable plastic body for reliable performance, offering a safe, contactless solution for monitoring body temperature, ideal for public health and safety applications. Microcontroller: ESP8266 for wireless connectivityDisplay: OLED screen for temperature readingsTemperature Sensor: Infrared sensor for touch-free measurementDistance Sensor: Ultrasonic sensor to detect person within 10 cmLED Indicators: Green LED for rmal temperature, red LED for high temperatureBuzzer: Alerts when temperature is above rmal rangeBody: Durable plastic for reliable performanceOne pair of PCB and Mechanical Design will be provided 11.2 Sun Quest Sun Quest model should include an Ardui Na, two LDR modules, a servomotor, a solar panel, and two LEDs to maximize energy efficiency. The LDR modules detect light intensity, enabling the system to track the sun’s position. When one LDR senses higher light intensity, the servo motor should rotate the solar panel toward that direction to optimize energy capture. The LEDs connected to the solar panel will demonstrate real-time power generation, lighting up to show how current is produced as the panel adjusts. The design must feature a durable plastic body for longevity, enhancing solar energy efficiency by dynamically following the sun’s path throughout the day. Microcontroller: Ardui Na for system controlLight Sensors: Two LDR modules for detecting light intensityActuator: Servo motor for rotating the solar panelSolar Panel: Generates and demonstrates power outputLED Indicators: Show real-time power generationBody: Durable plastic for longevity One pair of PCB and Mechanical Design will be provided 1 11.3 LightScape Lightscape model should include an Ardui Na, LDR module, IR sensor, and 6 LEDs to optimize energy usage based on environmental conditions. When the LDR detects darkness (indicating nighttime), the system should activate, keeping 3 LEDs ON for basic lighting. When the IR sensor detects movement, all 6 LEDs should turn ON for 5 seconds to enhance visibility for pedestrians or vehicles, then return to 3 LEDs ON. During daylight, when the LDR senses light, the LEDs should remain OFF to conserve energy. The design must feature a durable plastic body for reliability, providing efficient, adaptive street lighting that responds to both time of day and movement, significantly improving energy conservation and safety on the streets. Microcontroller: Ardui Na for system automationSensors: LDR for detecting light levels, IR sensor for motion detectionLEDs: 6 LEDs for adaptive street lightingLighting Control: 3 LEDs ON at night, all 6 ON when motion is detected for 5 secondsEnergy Conservation: LEDs OFF during daylight Body: Durable plastic for reliabilityOne pair of PCB and Mechanical Design will be provided 1 11.4 Navwave NavWave is a sonar-inspired object detection system, and the model should include an ESP8266, OLED display, ultrasonic sensor, and servo motor to detect and display nearby objects. The ultrasonic sensor, mounted on the servo motor, should continuously rotate from 0 to 180 degrees, scanning the surroundings for obstacles. As objects are detected, the system should display a dotted pattern on the OLED screen, similar to a submarine radar interface, providing a real-time visual representation of object proximity and location. The design must feature a durable plastic body for reliability, simulating sonar navigation and offering a dynamic way to monitor nearby obstacles through the rotating ultrasonic sensor and radar-like display. Its robust design ensures optimal performance in various environments, making it an excellent tool for obstacle detection and navigation. •Microcontroller: ESP8266 for processing and wireless capabilityDisplay: OLED screen with radar-like visual representationSensor: Ultrasonic sensor for object detectionActuator: Servo motor for 0°-180° scanning motionDetection Mechanism: Real-time scanning and obstacle mappingBody: Durable plastic for reliabilityOne pair of PCB and Mechanical 1 34 Design will be provided 12 Electronics & Hardware Kit Universal Electrical/Electronic breadboard plug and play training kit designed to perform the experiments from the basic to advance level of electrical and electronics exercises, This kit is made easy to conduct experiments by plugging in the components in to the specifically designed breadboard. Should have built-in Function generator, power supply and required meters List of components Resistors SetPotentiometers n-linear resistors VDR-, LDR-, NTC-, PTC resistors Capacitors SetTransformer 1 13.1 Experiential Skilling Lab set Electrical Booth Spec - 01 Each workstation should have dimensions of 4 ft width and 6 ft height. The material used for the workstations construction must be high-quality plywood with a thickness of at least 10mm, ensuring durability and stability. The workstation should be designed in a plus-shaped configuration, where each arm of the plus symbol represents an individual training domain. The work station should have 4 station where, Electrical installation, Plumbing and CCTV installation can be practiced All necessaries aids for this training should be provided in this work station 1 13.2 CCTV Installation kit To provide a comprehensive training setup for students to learn and practice the installation, configuration, and maintenance of CCTV systems, including cabling, DVR setup, and network integration for monitoring and recording. Dome Cameras –1 Bullet Camera-1 DVR/NVR Unit -1 Cables and AccessoriesPower Supply with adaptorsSwitch and RouterDisplay and MonitoringNetworking Tools 1 13.3 Domestic Electric Wiring Kit To provide a comprehensive training setup for students to learn and practice the installation, wiring, and maintenance of domestic Electric wiring methods, includes reading and understanding electrical drawings, Switch gears and colour coding of cables. Domestic electric wiring kit – 1 set MCB, 4P, 25ADistribution Box 3 tier 36 modules RCCB 2P 40A 30mA ACtypeMCB xC60 1P 2A C 10000A6A 1-WAY SWITCH 6A 2-way Switch6A/16A 3-Pin Socket Outlet PVC Casing-Capping, 50mmPVC CasingCapping, 25mmPVC Conduit, High density, 19mmSaddles, 19 mmPOP screwPVC Junction Box 19mm, 1 wayPVC Junction Box 19mm, 2 wayPVC Junction Box 19mm, 3 wayPVC Junction Box 19mm, 4 wayBatten Holder2- Module Box with surface plate, PVC4-Module Box, PVC8-Module Box, PVCTools – 1 set 12V Cordless Drill machinePhilip bit Spirit Level, 30 cm Steel Rule, 30 Cm Wire Stripper Heavy duty cable cutter Try square Measurement tape Mini Hack Saw frame with blades Hack Saw Frame with blades Crimping tool, tube type lugs File Set Electrician knifeAllen key set Hole saw, 22 mm Screw Driver set se plier Drill Bit Set Mini screw driver set Aluminum Stair Case, 3 step 1 13.4 Plumbing Installation Setup To equip a plumbing training lab with all necessary tools and equipment to provide students with hands-on experience in basic and advanced plumbing techniques, including pipe fitting, jointing, fixture installation, and system testing. Tools for Pipe Cutting and ShapingPipe Cutter:Hacksaw:Pipe Bender:PVC Pipe Cutting Scissors:Tools for Threading and JoiningPipe Threaded Set: Teflon Tape Dispenser:Plumbers Soldering Kit:Adhesive Application Kit: Wrenches and SpannersAdjustable Pipe Wrench:Basin Wrench:Ring Spanner Set:Testing and Measurement ToolsWater Pressure Gauge: Flow Rate Meter:Leak Detection Kit: Spirit Level:Plumbing Fixtures for Installation PracticeSink and Basin Fixtures:Faucets and Taps:Shower Unit: Drainage System ComponentsP-traps and S-traps:Wastewater Pipes:Junction Boxes: 1 14 Smart Solar Renewable Energy Kit Solar Photovoltaic Training Kit for Lab experimentsPV Module Stand: 2s. 1 35 15 SAM S-5 Missile Educational Training Kit Missile defense systems are essential for national security, airspace protection, and strategic deterrence. This will explore the working principles of the missile system, focusing on its launch mechanism, guidance techlogy, and interception capabilities. Additionally, it will analyze the applications of the model in air defense, including target tracking, threat neutralization, and military strategy. SAM S-5 Missile System should consist of the following items. Raspberry Pi x 1Camera Module x 1Lidar or Ultrasonic sensor x 1 Servo MotorsGyroscope x 1Shooter x 1Battery x 1 Battery Adapter x 1 1 16 GEO Satellite Communication Educational Training Kit Satellites play a crucial role in modern communication, navigation, weather forecasting, and scientific research. This will explore the communication and data transmission process in GEO satellites analyze the applications of GEO satellites in telecommunications, weather forecasting, and remote sensing. GEO Satellite Communication Kit should consist of the following items. Raspberry Pi x 3ESP8266 x 3ZigBee Module and adapter x 3 RF Module x 3 Temperature and Humidity Sensor x 2 Soil Moisture Sensor x 1 NPK Sensor x 1 Pressure Sensor x 2Co2 Sensor x 1Camera Module x 1Buzzer x 3 LEDsRover Model x 1Base station Model x 1Battery Battery Adapter 1 17 LUNAR PATH Explorer- Educational Rover BOT It should comes with Matt finished metal chassis. Included all sensor metal clamps, and high torque DC Johnson A grade motors. Compatible with Ardui, raspberry, etc. Easy to assemble. Assembly manual provided in the kit. All required components, sensors, and tools are provided in the kit. It should consists of following items: 12V DC 10 RPM MOTORS -2ULTRASONIC SENSORS - 3IR SENSORS - 5 WIDE TRACK WHEELS - 4WIDE TRACK BELTNUT BOLTSSPANNER TWO IN ONE SCREWDRIVER,JUMPER WIRESSG90 SERVO MOTOR -1 ON/OFF ROCKER SWITCH -2TOGGLE SWITCH - 2MOTOR WIRES 1 18 Package . 1 Atal Tinkering Lab The package should include all items As per QR/specification for Package . 1 - Atal Tinkering Lab of NITI AAYOG Electronics Development, Robotics, Internet of Things and Sensors approved by NITI AAYOG (Approved Copy of Qrs / Specification uploaded in Gem portal) Specification: Microcontrollers & Boards:Ardui U/Na/Mega (or equivalents).Raspberry Pi 3 Model B+.ESP32, de MCU.Prototyping Tools:Solderless breadboards (400 and 800 pins).Self-adhesive proto shield and FR2 A-grade materials.Hook-up wires, jumper cables (M-M, M-F, F-F), and alligator connectors.Sensors & Modules:Wide range of sensors: Humidity, temperature, motion, gas (MQ series), IR, ultrasonic, PIR, and more.RFID Reader, Bluetooth, GSM, GPS, and Wi-Fi modules.Capacitive touch, soil moisture, rain, and color recognition sensors.Displays & Actuators:16x2 LCD display with I2C interface. LED matrices, RGB LEDs, and various single-color LEDs.Motors: DC, stepper, servo, vibrating, and BO motor with driver modules.Miscellaneous Components: Resistor and capacitor kits, diodes, transistors, and ICs (LM555).Relays, motor drivers, and piezoelectric plates.Robotics, drone, and application-specific DIY kitsPower & Connectivity:USB cables, battery packs, power banks, and clips. 1 19 Package . 2 Atal Tinkering Lab – Rapid Prototyping Tools The Package should include all items As per QR/specification for Package .2 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specifications: 3D Printer Kit and tools Dedicated UPS/Power back up Filament for 3D printer Filament Storage Box Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materials 1 20 Package . 3 Atal Tinkering Lab – Mechanical, Electrical and Measurement Tools The package should include all items As per QR/specification for Package .3 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI 1 36 AAYOG Specification: Cutting Tools: Hacksaw frame with blades (standard & mini).File set, mini file set, and flexible cutting mat. Hand Tools: Pliers (4.5-inch), tweezers, ball pein hammer, claw hammer, C-clamp, spanner set, Allen key set, wrench, and wire strippers. Drilling Tools: Drill machine set with workstation.Drill bit set and vice (rmal). Screwdrivers & Soldering Tools: Precision screwdriver set, electric screwdriver set, soldering kit, and soldering helping hand. Measuring & Testing Tools: Digital multi meter, digital Vernier caliper, spirit level, measuring tape, and pen electric tester. Digital oscilloscope, adapters, telescope, DIY paper microscope Power Tools: Cordless rotary multi tool, dual-temperature heat gun, air blower, and hot glue gun.Organization & Workspace: Plastic trays, pegboard, and return measuring tools 21 Intel Core i5 - 1245U Mid Level Laptop - tebook Specification: Laptop Type: Mid LevelIntel Core i5 - 1245UOperating System (Factory PreLoaded)Window 11 HomeRAM Size (GB)16Display Size (in cm) – Diagonal: 35.56 to 38.09 (14 In to 14.99 In)Capacity of Storage Drive (in GB)512 1 22 65 Inch Display Interactive Panel with CPU Size (Diagonal): 65 or higher Panel Techlogy: IPS / VA Resolution: (Minimum) 4K (3840 x 2160) Viewing Angle (Hx V): 178*178RAM: 4 GB or higher On-board memory: 32 GB or higher Input (Minimum): 3 x HDMI, 4 x USB (Out of, which min 2xUSB3.0),1 xAudio, 1 x OPS slot, 1 x USB Type C Port Output: (Minimum) 1 x HDMI, 1 x Audio The software enables teachers to generate presentations using Al in PPT or PDF format. The teachers can select their Class, Subject, Topic and language to generate the presentations. The software supports all Indian and Global languages including English, Hindi, Marathi, Kannada, Tamil, Telugu, Gujarati, etc. Using Al, the software is able to analyse the Class and Subject and generate output accordingly. Using the Ask Me Anything tool, the teachers can search queries related to any topic and the Al is able to generate Class-wise and Subject-wise results including Images, Videos (YouTube Videos) and Explanation. Connected Classroom Software has in-built Generative Al capability to search and import filtered content relevant to Class and Subject. - images, videos, explanation for queries given by teachers in all languages. Teachers are able to import images and videos for teaching in class. The software has a text-to-speech function (for all languages) to convert text-based explanation into speech and read out loud in class. Software has Two-Way Live Conferencing Feature with education specific features Live conferencing feature also enables recording which gets directly uploaded to cloud.. Reports: Detailed reports for Attendance, Assessments, Study Material, are available for administrators to access. Administrators should be able to access to view the whiteboard saved by the teachers and monitor the usage.. Below tools and simulations are provided for enhancing the teaching-learning experience: - Graph: Demonstrating equations using 2D and 3D visualizations - Calculator: Standard and scientific - PHET simulation library with 100+ simulations across Maths, Physics, Chemistry, Biology. 1 23 2 kVA OFF LINE UPS Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 1 24 Battery 75/80 AH capacity Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 1 25 6Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 37 26 8 Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire with switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch 1 28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire without switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 1 29 1.5 mm2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 30 Fans : 48 Sweep (1200 mm) Regular model Supplying capacitor type ceiling fan complete with down rod blades, shackle, capies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 1 31 LED Down Light 15-18W Supplying of recess mounting n integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 1 32 Fall Ceiling for Invation lab to cover entire Area Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. 1 33 Floor Mat for Invation lab to Cover the entire Lab Providing and laying lileum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications 1 34 Repair and Replacement of Windows and Doors (if required) Repairing door and window frames with available wood to the required size. 1 35 Painting Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² 1 38 with paint of approved quality to give an even shade, after thoroughly rooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-ccharge. (The gloss should be 50% @ 60 degree angle with 10 years life) 36 Providing and laying Cement concrete flooring 40 mm thick with 20 mm minal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete.(P .59, SI. 9.1 PWD SR 2023-24 Volume 2) 1 37 Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification.( SI. 8.33.1 PWD SR 2023-24 Volume 2) 1 38 Polyurethane based ingle Component for Existing surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content t less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification (P .A-149, SI. 15.2 PWD SR 2023-24 Volume 1) 1 39 Model Table - Modular Table with MDF Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 1 40 Student Table - Modular Table with Particle Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to 1 39 be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 41 Trainer Table - Executive Table with Pedestal, 3 Side Storage Unit 1 42 Student Chair – Providing and supplying Unbranded wood chair/stool, already assembled Technical Specifcation Chair feature painting. Color-Other, Style Traditional. Furniture Assembly Already Assembled. Material Wood. Additional Parameters Additional Features good quality wooden arm chairs. 1 43 Trainer Chair - Revolving Chair with Synchronic tilt mechanism 1 44 Training of Teachers The Master Trainer will conduct a 2-day Training of Trainers (ToT) program for educators on effectively utilizing the Invation Lab . The training should cover hands-on learning methodologies, STEM education, and practical applications of lab tools and techlogies (P .A-48, SI. 1 PWD SR 2023-24 Volume 1)
Contract Date: Ref. Documents Contract Value : 53.34 Lakh
Government Departments No of Bidders 1
43.
Housing Urban and Rular Development #8768112 AOC
Tender For Providing, Supplying, Commissioning Of Innovation Lab Equipments For Ghs Yerragudi Village In Ballari Taluk, Under 2515 Kkrdb Cmdq For The Year 2024-25.-Six Axis Robotic ARM Consists of •Axis – 6 axis•64- bit ARM Cortex Processor8GB RAM64 GB Storage CapacityServo Motors with 9.6 Kg/cm Torque Payload – 200gReach – 200 mmUSB Support port Should have 8 MP Camera User can add various objects for detection Should identify pre trained Objects Should perform pick and place operation Dimension in mm(D x H): 1100 x 600 One pair of PCB and Mechanical casing should be provided 1 2 Petro robot it should consists of Should have 8 MP Camera 64 bit ARM Cortex Processor 2-D Lidar Sensor Person Recognitiobject Recognition Should consists of 4 leg armShould perform forward and reverse motion Should have rechargeable battery Should have 12 V rechargeable BatteryPower Adapter for Battery Recharge •Dimension in cm (L x W x H): 62 x 20 x 45•One pair of PCB and Mechanical casing should be provided •Tasks performed: 1. Walking2. Running3. Pushups4. Dance5. Jumping6. Sit and Stand positions7. Lane following 1 3 Line Following robo car it should consists of A Robotic car with 4 wheelsShould have 2 IR sensors Should have 4 DC motors Atmega 328P Microcontroller L298 Motor Driver for Direction and Speed control Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5 Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: Straight Weight: 250gm•One pair of PCB and Mechanical casing should be provided 1 4 Obstacle avoidance robo car it shouldconsists of Robotic Car with 4 Wheels Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8 Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 5 Voice controlled Robo Car it should consists of 1 30 Robotic Car with 4 Wheels DC motors with drivesBluetooth controllerShould perform motions by voice command Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22 mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (KgCm): 0.8Gearbox Shape: Straight Weight: 250gm •One pair of PCB and Mechanical casing should be provided 6 RC Tank Robot RC Tank Chassis Kit – 01ESP32 controllerLED Switch4 DC motors with Drive Battery 4 DC motors with drive ESP32 controllerDimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 7 AI Humaid Robot The AI Humaid robot can realize human body induction in different directions, can perform facial recognition, supports voice interaction, and can realize the function of guiding navigation and explaining. Should have obstacle avoidance algorithm, perceive the real-time changes in the surrounding environment, bypass the obstacles in the planned path, and choose the appropriate route Go forward and finally reach the target point. The robot should have a touchable high-definition display screen, which should display, video playback, product information query, map display and other functions. The robot should have an open SDK package and an open API, which can be used for development according to the application scenario, adding exclusive personality functions, and more in line with the actual application scenario. Technical specifications include a user-friendly interface, robust security measures, seamless integration, efficient performance, and scalability. Specification: Processor: Intel i5 8th Gen Motors: DC motors for smooth and precise movement.Microphone: High-sensitivity microphone for voice recognition and interaction.Speakers: High-quality speakers for audio output and ntertainment. Display: LCD display for user interaction, information visualization. Dimension in cm(L x W x H): 50 x 54 x 100 1 8.1 IoT Pack IoT Based Smart Agriculture Smart Agriculture model should include an Raspberry Pi, a 10 inch LCD display, soil moisture sensor, water pump, and relay to automate irrigation for plants. The soil moisture sensor should continuously monitor the moisture levels in the soil. When the soil is wet, the relay should remain off, preventing the pump from operating. However, when the soil moisture level drops and becomes dry, the relay should activate, turning on the water pump to irrigate the soil. The LCD display should provide real-time feedback on soil moisture levels, ensuring efficient water management and promoting healthy plant growth. Constructed with a durable plastic body for resilience, this project demonstrates the effectiveness of smart techlogy in modern agriculture, optimizing water usage and enhancing crop health while ensuring reliable performance in various environmental conditions. Microcontroller: Raspberry piSoil Moisture Sensor – Measures soil humidity levels.DHT11/DHT22 Sensor – Monitors temperature and humidity.pH Sensor – Checks soil acidity or alkalinity.LDR (Light Sensor) – Detects sunlight intensity.Rain Sensor – Detects rainfall for irrigation control.Ultrasonic Sensor – Monitors water level in tanks.Water Pump – Automated irrigation control via relay.Servo Motor – Adjusts solar panel orientation.Relay Module (5V) – Controls high-power devices.IoT Connectivity – Data transmission via WiFi/Bluetooth.Cloud Storage – Stores real-time sensor data online.Web App – Displays real-time farm conditions.Power Adapter – Powers all connected components. 1 8.2 IoT Based Home Automation The Home Automation System model should include a Raspberry Pi, MQ-2 gas 1 31 sensor, buzzer, ultrasonic sensor, servo motor, 7-inch display, DHT11 temperature sensor, and two relays to enhance home convenience and safety. The ultrasonic sensor should detect approaching objects, triggering the servo motor to automatically open the door, while the 7-inch display presents real-time temperature readings. In one room, an IR sensor should detect motion, activating the relay to turn on an LED and a fan. Additionally, when the MQ-2 sensor detects smoke in the kitchen, the buzzer should sound an alert until the smoke dissipates. The system must feature a durable plastic body for reliability and easy assembly, showcasing the seamless integration of smart techlogies to create a safer and more efficient living environment, ensuring enhanced convenience and security. Microcontroller: Raspberry Pi for central control with WiFi and Bluetooth Ram: 4GB64 bit ARM Cortex ControllerGas Detection: MQ-2 sensor to detect smoke and gas leaksAlert System: Buzzer sounds when smoke is detectedObject Detection: Ultrasonic sensor detects approaching objects for automatic door controlDoor Mechanism: Servo motor opens the door upon object detectionDisplay: 7-inch screen for real-time temperature and system statusTemperature Monitoring: DHT11 sensor measures room temperature and humidityMotion Detection: IR sensor detects movement in the room Relay Module (x2): Controls LED and fan activationLighting & Ventilation: LED and fan turn on when motion is detectedBody: Durable plastic for reliability and easy assembly 8.3 Smart Watch health parameter monitoring kit Smart Watch is an invative wearable device project, and the model should include an ESP processor, OLED display, and four push buttons to provide a range of functionalities. The watch must feature a custom-designed PCB for compactness and efficiency, along with a durable watch belt for comfortable wear. One push button should be dedicated to displaying the current time, date, and day, while ather button should provide weather information, enhancing convenience for users. The remaining two buttons should be integrated for the IoT interface, allowing interaction with various smart devices and applications. This project demonstrates the potential of combining advanced techlogy with practical design, creating a multifunctional smartwatch that caters to modern lifestyle needs, ensuring reliability and user-friendly operation. ESP Processor – Core controller for smartwatch operations. OLED Display – Displays time, date, weather, and IoT interactions. Four Push Buttons – Dedicated for time, date, weather, and IoT control. Custom-Designed PCB – Ensures compactness and efficiency. Durable Watch Belt – Provides comfort for daily wear. Time, Date, and Day Display – Activated by a dedicated button. Weather Information Display – Accessed via a separate button. IoT Integration – Controls and interacts with smart devices. Energy-Efficient Design – Optimized for long battery life. Modern & User-Friendly – Enhances convenience and usability. 1 8.4 IoT Based Smart Cam Vision Snap should consist of an advanced security system that includes facial recognition for identifying individuals, enhancing security in restricted areas. Key components include a Raspberry Pi, a camera, and a display for real-time monitoring. This system features motion detection, which triggers alerts for unauthorized movement, significantly improving surveillance capabilities. It provides real-time alerts, enabling immediate responses to potential threats, while secure connectivity ensures the protection of sensitive data. Together, these features create a robust security solution for various applications, making Vision Snap an effective tool for safeguarding premises and enhancing overall security measures. Raspberry Pi – Central processing unit for AI-based security.Camera Module – Captures real-time footage and facial recognition.Display Screen – Shows live monitoring and alerts.Facial Recognition – Identifies individuals for security access.Motion Detection – Detects unauthorized movement and triggers alerts.Real-Time Alerts – Sends tifications for immediate response.Secure Connectivity – Protects sensitive surveillance data.AI-Powered Surveillance – 1 32 Enhances monitoring efficiency.Remote Access – Allows monitoring from any location.Robust Security System – Ideal for restricted areas and premises. 9.1 Immersive Techlogy Pack VR Headset Kit Should Consist of Following Line Item VR Head Set Storage: 512GBDisplay: Each eye experiences a resolution of 2064 x 2208 pixels, delivering sharp and immersive visuals.Processor: Powered by the Snapdragon XR2 Gen 2 chipset, providing enhanced performance for demanding VR applications.Refresh Rate: Supports a 120Hz refresh rate, ensuring smooth and responsive gameplay.Memory: Equipped with 8GB of RAM to handle multitasking and complex VR environments.Mixed Reality Capabilities: Features full-color passthrough, allowing users to blend virtual and real-world elements seamlessly.Design: Utilizes pancake optics to reduce the headsets size, offering a more comfortable fit for extended use. 1 9.2 32-inch or more smart LED TV to Stream a VR applications Resolution: HD (720p)Smart Platform: Google TVFeatures: Google Play, Google Cast Built-in, HDR10, Dolby Audio, Voice Remote, Live TV Streaming 1 9.3 AA Batteries – 10 Voltage: 3.7V (Lithium-Ion)Capacity: 1800–3500 mAhChemistry Types: Alkaline, NiMH (Rechargeable), Lithium, Zinc-CarbonSize: Diameter ~14.5mm, Length ~50.5mmWeight: ~23g to 30g 1 9.4 6DoF AR-VR Educational Controller can be used as and augmented reality (AR) device. Hold virtual heart, lungs, disaurs, plants and so much more in your hand to get an engaging learning experience. AR provides students with opportunities to deepen their kwledge within several areas, including:ScienceWorking with numbersSpatial concepts Content creationReal-life environments & scenarios 1 9.5 Samsung Galaxy M15 5G or ARCore supported Devices Display: 6.5-inch Super AMOLED, 1080 x 2340 pixelsProcessor: MediaTek Dimensity 6100+, Octa-coreRAM & Storage: 4GB/6GB/8GB RAM, 28GB/256GB storage (expandable up to 1TB)Rear Cameras: 50MP (wide) + 5MP (ultra-wide) + 2MP (macro)Front Camera: 13MPBattery: 6,000mAh, 25W fast charging OS: Android 14 with One UI 6Security: Side-mounted fingerprint sensor Connectivity: 5G, NFC supportDimensions: 160.1 x 76.8 x 9.3mm, Weight : 217g 1 9.6 VR Application Content for experintial learning a) VR chemistry lab, b) VR human anatomy, c) VR tour guide, d) VR English Learning App, e) VR space exploration app, f) VR electrical simulator app, g) VR Based Lathe Machine app, h) VR Based SMD Soldering & De soldering app 1 10 Drone Kit Should Consist of Following Line Item. Drone Kit with Wi-Fi and Camera is an ideal project for enthusiasts looking to build a custom drone from the ground up. This kit typically includes essential components such as a frame, brushless motors (BLDC), electronic speed controllers (ESCs), a flight controller board (FCB), and a Wi-Fi-enabled camera for real-time video transmission. It offers the flexibility of adding a LiPo battery for power, a remote controller, and propellers for flight stability. With built-in WiFi, users can easily control and monitor the drone using a mobile app or computer, while the camera provides aerial photography and video streaming capabilities. 1 x F450 Frame 4 x 1000kv BLDC Motor 4 x ESC Motor 1 x 2-3 Cell Battery Charger1 x 2200 mAh Lipo Battery1 x Fly Sky FS-CT6B 6ch 2.4GHz Transmitter & Receiver1 x APM 2.8 Flight Controller (Without Compass) 1 11.1 Mini Makers Pack Thermo Sage Thermo Sage is a touch-free temperature monitoring system, and the model should include an ESP8266, OLED display, infrared temperature sensor, ultrasonic sensor, two LEDs, and a buzzer for efficient health monitoring. When the ultrasonic sensor detects a person within 10 cm, the infrared sensor measures their body temperature, displaying the result on the OLED screen. If the temperature is 1 33 rmal, the green LED lights up as an indication. However, if the temperature exceeds the rmal range, the red LED activates, and the buzzer sounds an alert. The design must feature a durable plastic body for reliable performance, offering a safe, contactless solution for monitoring body temperature, ideal for public health and safety applications. Microcontroller: ESP8266 for wireless connectivityDisplay: OLED screen for temperature readingsTemperature Sensor: Infrared sensor for touch-free measurementDistance Sensor: Ultrasonic sensor to detect person within 10 cmLED Indicators: Green LED for rmal temperature, red LED for high temperatureBuzzer: Alerts when temperature is above rmal rangeBody: Durable plastic for reliable performanceOne pair of PCB and Mechanical Design will be provided 11.2 Sun Quest Sun Quest model should include an Ardui Na, two LDR modules, a servomotor, a solar panel, and two LEDs to maximize energy efficiency. The LDR modules detect light intensity, enabling the system to track the sun’s position. When one LDR senses higher light intensity, the servo motor should rotate the solar panel toward that direction to optimize energy capture. The LEDs connected to the solar panel will demonstrate real-time power generation, lighting up to show how current is produced as the panel adjusts. The design must feature a durable plastic body for longevity, enhancing solar energy efficiency by dynamically following the sun’s path throughout the day. Microcontroller: Ardui Na for system controlLight Sensors: Two LDR modules for detecting light intensityActuator: Servo motor for rotating the solar panelSolar Panel: Generates and demonstrates power outputLED Indicators: Show real-time power generationBody: Durable plastic for longevity One pair of PCB and Mechanical Design will be provided 1 11.3 LightScape Lightscape model should include an Ardui Na, LDR module, IR sensor, and 6 LEDs to optimize energy usage based on environmental conditions. When the LDR detects darkness (indicating nighttime), the system should activate, keeping 3 LEDs ON for basic lighting. When the IR sensor detects movement, all 6 LEDs should turn ON for 5 seconds to enhance visibility for pedestrians or vehicles, then return to 3 LEDs ON. During daylight, when the LDR senses light, the LEDs should remain OFF to conserve energy. The design must feature a durable plastic body for reliability, providing efficient, adaptive street lighting that responds to both time of day and movement, significantly improving energy conservation and safety on the streets. Microcontroller: Ardui Na for system automationSensors: LDR for detecting light levels, IR sensor for motion detectionLEDs: 6 LEDs for adaptive street lightingLighting Control: 3 LEDs ON at night, all 6 ON when motion is detected for 5 secondsEnergy Conservation: LEDs OFF during daylight Body: Durable plastic for reliabilityOne pair of PCB and Mechanical Design will be provided 1 11.4 Navwave NavWave is a sonar-inspired object detection system, and the model should include an ESP8266, OLED display, ultrasonic sensor, and servo motor to detect and display nearby objects. The ultrasonic sensor, mounted on the servo motor, should continuously rotate from 0 to 180 degrees, scanning the surroundings for obstacles. As objects are detected, the system should display a dotted pattern on the OLED screen, similar to a submarine radar interface, providing a real-time visual representation of object proximity and location. The design must feature a durable plastic body for reliability, simulating sonar navigation and offering a dynamic way to monitor nearby obstacles through the rotating ultrasonic sensor and radar-like display. Its robust design ensures optimal performance in various environments, making it an excellent tool for obstacle detection and navigation. •Microcontroller: ESP8266 for processing and wireless capabilityDisplay: OLED screen with radar-like visual representationSensor: Ultrasonic sensor for object detectionActuator: Servo motor for 0°-180° scanning motionDetection Mechanism: Real-time scanning and obstacle mappingBody: Durable plastic for reliabilityOne pair of PCB and Mechanical 1 34 Design will be provided 12 Electronics & Hardware Kit Universal Electrical/Electronic breadboard plug and play training kit designed to perform the experiments from the basic to advance level of electrical and electronics exercises, This kit is made easy to conduct experiments by plugging in the components in to the specifically designed breadboard. Should have built-in Function generator, power supply and required meters List of components Resistors SetPotentiometers n-linear resistors VDR-, LDR-, NTC-, PTC resistors Capacitors SetTransformer 1 13.1 Experiential Skilling Lab set Electrical Booth Spec - 01 Each workstation should have dimensions of 4 ft width and 6 ft height. The material used for the workstations construction must be high-quality plywood with a thickness of at least 10mm, ensuring durability and stability. The workstation should be designed in a plus-shaped configuration, where each arm of the plus symbol represents an individual training domain. The work station should have 4 station where, Electrical installation, Plumbing and CCTV installation can be practiced All necessaries aids for this training should be provided in this work station 1 13.2 CCTV Installation kit To provide a comprehensive training setup for students to learn and practice the installation, configuration, and maintenance of CCTV systems, including cabling, DVR setup, and network integration for monitoring and recording. Dome Cameras –1 Bullet Camera-1 DVR/NVR Unit -1 Cables and AccessoriesPower Supply with adaptorsSwitch and RouterDisplay and MonitoringNetworking Tools 1 13.3 Domestic Electric Wiring Kit To provide a comprehensive training setup for students to learn and practice the installation, wiring, and maintenance of domestic Electric wiring methods, includes reading and understanding electrical drawings, Switch gears and colour coding of cables. Domestic electric wiring kit – 1 set MCB, 4P, 25ADistribution Box 3 tier 36 modules RCCB 2P 40A 30mA ACtypeMCB xC60 1P 2A C 10000A6A 1-WAY SWITCH 6A 2-way Switch6A/16A 3-Pin Socket Outlet PVC Casing-Capping, 50mmPVC CasingCapping, 25mmPVC Conduit, High density, 19mmSaddles, 19 mmPOP screwPVC Junction Box 19mm, 1 wayPVC Junction Box 19mm, 2 wayPVC Junction Box 19mm, 3 wayPVC Junction Box 19mm, 4 wayBatten Holder2- Module Box with surface plate, PVC4-Module Box, PVC8-Module Box, PVCTools – 1 set 12V Cordless Drill machinePhilip bit Spirit Level, 30 cm Steel Rule, 30 Cm Wire Stripper Heavy duty cable cutter Try square Measurement tape Mini Hack Saw frame with blades Hack Saw Frame with blades Crimping tool, tube type lugs File Set Electrician knifeAllen key set Hole saw, 22 mm Screw Driver set se plier Drill Bit Set Mini screw driver set Aluminum Stair Case, 3 step 1 13.4 Plumbing Installation Setup To equip a plumbing training lab with all necessary tools and equipment to provide students with hands-on experience in basic and advanced plumbing techniques, including pipe fitting, jointing, fixture installation, and system testing. Tools for Pipe Cutting and ShapingPipe Cutter:Hacksaw:Pipe Bender:PVC Pipe Cutting Scissors:Tools for Threading and JoiningPipe Threaded Set: Teflon Tape Dispenser:Plumbers Soldering Kit:Adhesive Application Kit: Wrenches and SpannersAdjustable Pipe Wrench:Basin Wrench:Ring Spanner Set:Testing and Measurement ToolsWater Pressure Gauge: Flow Rate Meter:Leak Detection Kit: Spirit Level:Plumbing Fixtures for Installation PracticeSink and Basin Fixtures:Faucets and Taps:Shower Unit: Drainage System ComponentsP-traps and S-traps:Wastewater Pipes:Junction Boxes: 1 14 Smart Solar Renewable Energy Kit Solar Photovoltaic Training Kit for Lab experimentsPV Module Stand: 2s. 1 35 15 SAM S-5 Missile Educational Training Kit Missile defense systems are essential for national security, airspace protection, and strategic deterrence. This will explore the working principles of the missile system, focusing on its launch mechanism, guidance techlogy, and interception capabilities. Additionally, it will analyze the applications of the model in air defense, including target tracking, threat neutralization, and military strategy. SAM S-5 Missile System should consist of the following items. Raspberry Pi x 1Camera Module x 1Lidar or Ultrasonic sensor x 1 Servo MotorsGyroscope x 1Shooter x 1Battery x 1 Battery Adapter x 1 1 16 GEO Satellite Communication Educational Training Kit Satellites play a crucial role in modern communication, navigation, weather forecasting, and scientific research. This will explore the communication and data transmission process in GEO satellites analyze the applications of GEO satellites in telecommunications, weather forecasting, and remote sensing. GEO Satellite Communication Kit should consist of the following items. Raspberry Pi x 3ESP8266 x 3ZigBee Module and adapter x 3 RF Module x 3 Temperature and Humidity Sensor x 2 Soil Moisture Sensor x 1 NPK Sensor x 1 Pressure Sensor x 2Co2 Sensor x 1Camera Module x 1Buzzer x 3 LEDsRover Model x 1Base station Model x 1Battery Battery Adapter 1 17 LUNAR PATH Explorer- Educational Rover BOT It should comes with Matt finished metal chassis. Included all sensor metal clamps, and high torque DC Johnson A grade motors. Compatible with Ardui, raspberry, etc. Easy to assemble. Assembly manual provided in the kit. All required components, sensors, and tools are provided in the kit. It should consists of following items: 12V DC 10 RPM MOTORS -2ULTRASONIC SENSORS - 3IR SENSORS - 5 WIDE TRACK WHEELS - 4WIDE TRACK BELTNUT BOLTSSPANNER TWO IN ONE SCREWDRIVER,JUMPER WIRESSG90 SERVO MOTOR -1 ON/OFF ROCKER SWITCH -2TOGGLE SWITCH - 2MOTOR WIRES 1 18 Package . 1 Atal Tinkering Lab The package should include all items As per QR/specification for Package . 1 - Atal Tinkering Lab of NITI AAYOG Electronics Development, Robotics, Internet of Things and Sensors approved by NITI AAYOG (Approved Copy of Qrs / Specification uploaded in Gem portal) Specification: Microcontrollers & Boards:Ardui U/Na/Mega (or equivalents).Raspberry Pi 3 Model B+.ESP32, de MCU.Prototyping Tools:Solderless breadboards (400 and 800 pins).Self-adhesive proto shield and FR2 A-grade materials.Hook-up wires, jumper cables (M-M, M-F, F-F), and alligator connectors.Sensors & Modules:Wide range of sensors: Humidity, temperature, motion, gas (MQ series), IR, ultrasonic, PIR, and more.RFID Reader, Bluetooth, GSM, GPS, and Wi-Fi modules.Capacitive touch, soil moisture, rain, and color recognition sensors.Displays & Actuators:16x2 LCD display with I2C interface. LED matrices, RGB LEDs, and various single-color LEDs.Motors: DC, stepper, servo, vibrating, and BO motor with driver modules.Miscellaneous Components: Resistor and capacitor kits, diodes, transistors, and ICs (LM555).Relays, motor drivers, and piezoelectric plates.Robotics, drone, and application-specific DIY kitsPower & Connectivity:USB cables, battery packs, power banks, and clips. 1 19 Package . 2 Atal Tinkering Lab – Rapid Prototyping Tools The Package should include all items As per QR/specification for Package .2 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specifications: 3D Printer Kit and tools Dedicated UPS/Power back up Filament for 3D printer Filament Storage Box Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materials 1 20 Package . 3 Atal Tinkering Lab – Mechanical, Electrical and Measurement Tools The package should include all items As per QR/specification for Package .3 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI 1 36 AAYOG Specification: Cutting Tools: Hacksaw frame with blades (standard & mini).File set, mini file set, and flexible cutting mat. Hand Tools: Pliers (4.5-inch), tweezers, ball pein hammer, claw hammer, C-clamp, spanner set, Allen key set, wrench, and wire strippers. Drilling Tools: Drill machine set with workstation.Drill bit set and vice (rmal). Screwdrivers & Soldering Tools: Precision screwdriver set, electric screwdriver set, soldering kit, and soldering helping hand. Measuring & Testing Tools: Digital multi meter, digital Vernier caliper, spirit level, measuring tape, and pen electric tester. Digital oscilloscope, adapters, telescope, DIY paper microscope Power Tools: Cordless rotary multi tool, dual-temperature heat gun, air blower, and hot glue gun.Organization & Workspace: Plastic trays, pegboard, and return measuring tools 21 Intel Core i5 - 1245U Mid Level Laptop - tebook Specification: Laptop Type: Mid LevelIntel Core i5 - 1245UOperating System (Factory PreLoaded)Window 11 HomeRAM Size (GB)16Display Size (in cm) – Diagonal: 35.56 to 38.09 (14 In to 14.99 In)Capacity of Storage Drive (in GB)512 1 22 65 Inch Display Interactive Panel with CPU Size (Diagonal): 65 or higher Panel Techlogy: IPS / VA Resolution: (Minimum) 4K (3840 x 2160) Viewing Angle (Hx V): 178*178RAM: 4 GB or higher On-board memory: 32 GB or higher Input (Minimum): 3 x HDMI, 4 x USB (Out of, which min 2xUSB3.0),1 xAudio, 1 x OPS slot, 1 x USB Type C Port Output: (Minimum) 1 x HDMI, 1 x Audio The software enables teachers to generate presentations using Al in PPT or PDF format. The teachers can select their Class, Subject, Topic and language to generate the presentations. The software supports all Indian and Global languages including English, Hindi, Marathi, Kannada, Tamil, Telugu, Gujarati, etc. Using Al, the software is able to analyse the Class and Subject and generate output accordingly. Using the Ask Me Anything tool, the teachers can search queries related to any topic and the Al is able to generate Class-wise and Subject-wise results including Images, Videos (YouTube Videos) and Explanation. Connected Classroom Software has in-built Generative Al capability to search and import filtered content relevant to Class and Subject. - images, videos, explanation for queries given by teachers in all languages. Teachers are able to import images and videos for teaching in class. The software has a text-to-speech function (for all languages) to convert text-based explanation into speech and read out loud in class. Software has Two-Way Live Conferencing Feature with education specific features Live conferencing feature also enables recording which gets directly uploaded to cloud.. Reports: Detailed reports for Attendance, Assessments, Study Material, are available for administrators to access. Administrators should be able to access to view the whiteboard saved by the teachers and monitor the usage.. Below tools and simulations are provided for enhancing the teaching-learning experience: - Graph: Demonstrating equations using 2D and 3D visualizations - Calculator: Standard and scientific - PHET simulation library with 100+ simulations across Maths, Physics, Chemistry, Biology. 1 23 2 kVA OFF LINE UPS Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 1 24 Battery 75/80 AH capacity Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 1 25 6Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 37 26 8 Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required s. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire with switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch 1 28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire without switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 1 29 1.5 mm2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 30 Fans : 48 Sweep (1200 mm) Regular model Supplying capacitor type ceiling fan complete with down rod blades, shackle, capies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 1 31 LED Down Light 15-18W Supplying of recess mounting n integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 1 32 Fall Ceiling for Invation lab to cover entire Area Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. 1 33 Floor Mat for Invation lab to Cover the entire Lab Providing and laying lileum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications 1 34 Repair and Replacement of Windows and Doors (if required) Repairing door and window frames with available wood to the required size. 1 35 Painting Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² 1 38 with paint of approved quality to give an even shade, after thoroughly rooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-ccharge. (The gloss should be 50% @ 60 degree angle with 10 years life) 36 Providing and laying Cement concrete flooring 40 mm thick with 20 mm minal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete.(P .59, SI. 9.1 PWD SR 2023-24 Volume 2) 1 37 Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification.( SI. 8.33.1 PWD SR 2023-24 Volume 2) 1 38 Polyurethane based ingle Component for Existing surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content t less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification (P .A-149, SI. 15.2 PWD SR 2023-24 Volume 1) 1 39 Model Table - Modular Table with MDF Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 1 40 Student Table - Modular Table with Particle Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to 1 39 be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface t to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 41 Trainer Table - Executive Table with Pedestal, 3 Side Storage Unit 1 42 Student Chair – Providing and supplying Unbranded wood chair/stool, already assembled Technical Specifcation Chair feature painting. Color-Other, Style Traditional. Furniture Assembly Already Assembled. Material Wood. Additional Parameters Additional Features good quality wooden arm chairs. 1 43 Trainer Chair - Revolving Chair with Synchronic tilt mechanism 1 44 Training of Teachers The Master Trainer will conduct a 2-day Training of Trainers (ToT) program for educators on effectively utilizing the Invation Lab . The training should cover hands-on learning methodologies, STEM education, and practical applications of lab tools and techlogies (P .A-48, SI. 1 PWD SR 2023-24 Volume 1)
Contract Date: Ref. Documents Contract Value : 53.34 Lakh
Government Departments No of Bidders 1
44.
Housing Urban and Rular Development #8768098 AOC
Providing, Supplying, Commissioning Of Innovation Lab Equipments For Ghs Banapura Village In Ballari Taluk, Under 2515 Kkrdb Cmdq For The Year 2024-25. Six Axis Robotic ARM Consists of •Axis – 6 axis•64- bit ARM Cortex Processor8GB RAM64 GB Storage CapacityServo Motors with 9.6 Kg/cm Torque Payload – 200gReach – 200 mmUSB Support port Should have 8 MP Camera User can add various objects for detection Should identify pre trained Objects Should perform pick and place operation Dimension in mm(D x H): 1100 x 600 One pair of PCB and Mechanical casing should be provided 1 YES 2 Petro robot it should consists of Should have 8 MP Camera 64 bit ARM Cortex Processor 2-D Lidar Sensor Person RecognitionObject Recognition Should consists of 4 leg armShould perform forward and reverse motion Should have rechargeable battery Should have 12 V rechargeable BatteryPower Adapter for Battery Recharge •Dimension in cm (L x W x H): 62 x 20 x 45•One pair of PCB and Mechanical casing should be provided •Tasks performed: 1. Walking2. Running3. Pushups4. Dance5. Jumping6. Sit and Stand positions7. Lane following 1 NO 3 Line Following robo car it should consists of A Robotic car with 4 wheelsShould have 2 IR sensors Should have 4 DC motors Atmega 328P Microcontroller L298 Motor Driver for Direction and Speed control Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5 Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: Straight Weight: 250gm•One pair of PCB and Mechanical casing should be provided 1 YES 4 Obstacle avoidance robo car it shouldconsists of Robotic Car with 4 Wheels Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8 Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 YES 5 Voice controlled Robo Car it should consists of Robotic Car with 4 Wheels DC motors with drivesBluetooth controllerShould perform motions by voice command Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22 mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (KgCm): 0.8Gearbox Shape: Straight Weight: 250gm •One pair of PCB and Mechanical casing should be provided 6 RC Tank Robot RC Tank Chassis Kit – 01ESP32 controllerLED Switch4 DC motors with Drive Battery 4 DC motors with drive ESP32 controllerDimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 1 YES 7 AI Humanoid Robot The AI Humanoid robot can realize human body induction in different directions, can perform facial recognition, supports voice interaction, and can realize the function of guiding navigation and explaining. Should have obstacle avoidance algorithm, perceive the real-time changes in the surrounding environment, bypass the obstacles in the planned path, and choose the appropriate route Go forward and finally reach the target point. The robot should have a touchable high-definition display screen, which should display, video playback, product information query, map display and other functions. The robot should have an open SDK package and an open API, which can be used for development according to the application scenario, adding exclusive personality functions, and more in line with the actual application scenario. Technical specifications include a user-friendly interface, robust security measures, seamless integration, efficient performance, and scalability. Specification: Processor: Intel i5 8th Gen Motors: DC motors for smooth and precise movement.Microphone: High-sensitivity microphone for voice recognition and interaction.Speakers: High-quality speakers for audio output and ntertainment. Display: LCD display for user interaction, information visualization. Dimension in cm(L x W x H): 50 x 54 x 100 1 YES 8.1 IoT Pack IoT Based Smart Agriculture Smart Agriculture model should include an Raspberry Pi, a 10 inch LCD display, soil moisture sensor, water pump, and relay to automate irrigation for plants. The soil moisture sensor should continuously monitor the moisture levels in the soil. When the soil is wet, the relay should remain off, preventing the pump from operating. However, when the soil moisture level drops and becomes dry, the relay should activate, turning on the water pump to irrigate the soil. The LCD display should provide real-time feedback on soil moisture levels, ensuring efficient water management and promoting healthy plant growth. Constructed with a durable plastic body for resilience, this project demonstrates the effectiveness of smart technology in modern agriculture, optimizing water usage and enhancing crop health while ensuring reliable performance in various environmental conditions. Microcontroller: Raspberry piSoil Moisture Sensor – Measures soil humidity levels.DHT11/DHT22 Sensor – Monitors temperature and humidity.pH Sensor – Checks soil acidity or alkalinity.LDR (Light Sensor) – Detects sunlight intensity.Rain Sensor – Detects rainfall for irrigation control.Ultrasonic Sensor – Monitors water level in tanks.Water Pump – Automated irrigation control via relay.Servo Motor – Adjusts solar panel orientation.Relay Module (5V) – Controls high-power devices.IoT Connectivity – Data transmission via WiFi/Bluetooth.Cloud Storage – Stores real-time sensor data online.Web App – Displays real-time farm conditions.Power Adapter – Powers all connected components. 1 YES 8.2 IoT Based Home Automation The Home Automation System model should include a Raspberry Pi, MQ-2 gassensor, buzzer, ultrasonic sensor, servo motor, 7-inch display, DHT11 temperature sensor, and two relays to enhance home convenience and safety. The ultrasonic sensor should detect approaching objects, triggering the servo motor to automatically open the door, while the 7-inch display presents real-time temperature readings. In one room, an IR sensor should detect motion, activating the relay to turn on an LED and a fan. Additionally, when the MQ-2 sensor detects smoke in the kitchen, the buzzer should sound an alert until the smoke dissipates. The system must feature a durable plastic body for reliability and easy assembly, showcasing the seamless integration of smart technologies to create a safer and more efficient living environment, ensuring enhanced convenience and security. Microcontroller: Raspberry Pi for central control with WiFi and Bluetooth Ram: 4GB64 bit ARM Cortex ControllerGas Detection: MQ-2 sensor to detect smoke and gas leaksAlert System: Buzzer sounds when smoke is detectedObject Detection: Ultrasonic sensor detects approaching objects for automatic door controlDoor Mechanism: Servo motor opens the door upon object detectionDisplay: 7-inch screen for real-time temperature and system statusTemperature Monitoring: DHT11 sensor measures room temperature and humidityMotion Detection: IR sensor detects movement in the room Relay Module (x2): Controls LED and fan activationLighting & Ventilation: LED and fan turn on when motion is detectedBody: Durable plastic for reliability and easy assembly 8.3 Smart Watch health parameter monitoring kit Smart Watch is an innovative wearable device project, and the model should include an ESP processor, OLED display, and four push buttons to provide a range of functionalities. The watch must feature a custom-designed PCB for compactness and efficiency, along with a durable watch belt for comfortable wear. One push button should be dedicated to displaying the current time, date, and day, while another button should provide weather information, enhancing convenience for users. The remaining two buttons should be integrated for the IoT interface, allowing interaction with various smart devices and applications. This project demonstrates the potential of combining advanced technology with practical design, creating a multifunctional smartwatch that caters to modern lifestyle needs, ensuring reliability and user-friendly operation. ESP Processor – Core controller for smartwatch operations. OLED Display – Displays time, date, weather, and IoT interactions. Four Push Buttons – Dedicated for time, date, weather, and IoT control. Custom-Designed PCB – Ensures compactness and efficiency. Durable Watch Belt – Provides comfort for daily wear. Time, Date, and Day Display – Activated by a dedicated button. Weather Information Display – Accessed via a separate button. IoT Integration – Controls and interacts with smart devices. Energy-Efficient Design – Optimized for long battery life. Modern & User-Friendly – Enhances convenience and usability. 1 NO 8.4 IoT Based Smart Cam Vision Snap should consist of an advanced security system that includes facial recognition for identifying individuals, enhancing security in restricted areas. Key components include a Raspberry Pi, a camera, and a display for real-time monitoring. This system features motion detection, which triggers alerts for unauthorized movement, significantly improving surveillance capabilities. It provides real-time alerts, enabling immediate responses to potential threats, while secure connectivity ensures the protection of sensitive data. Together, these features create a robust security solution for various applications, making Vision Snap an effective tool for safeguarding premises and enhancing overall security measures. Raspberry Pi – Central processing unit for AI-based security.Camera Module – Captures real-time footage and facial recognition.Display Screen – Shows live monitoring and alerts.Facial Recognition – Identifies individuals for security access.Motion Detection – Detects unauthorized movement and triggers alerts.Real-Time Alerts – Sends notifications for immediate response.Secure Connectivity – Protects sensitive surveillance data.AI-Powered Surveillance – 1 YES 32 Enhances monitoring efficiency.Remote Access – Allows monitoring from any location.Robust Security System – Ideal for restricted areas and premises. 9.1 Immersive Technology Pack VR Headset Kit Should Consist of Following Line Item VR Head Set Storage: 512GBDisplay: Each eye experiences a resolution of 2064 x 2208 pixels, delivering sharp and immersive visuals.Processor: Powered by the Snapdragon XR2 Gen 2 chipset, providing enhanced performance for demanding VR applications.Refresh Rate: Supports a 120Hz refresh rate, ensuring smooth and responsive gameplay.Memory: Equipped with 8GB of RAM to handle multitasking and complex VR environments.Mixed Reality Capabilities: Features full-color passthrough, allowing users to blend virtual and real-world elements seamlessly.Design: Utilizes pancake optics to reduce the headsets size, offering a more comfortable fit for extended use. 1 YES 9.2 32-inch or more smart LED TV to Stream a VR applications Resolution: HD (720p)Smart Platform: Google TVFeatures: Google Play, Google Cast Built-in, HDR10, Dolby Audio, Voice Remote, Live TV Streaming 1 YES 9.3 AA Batteries – 10 Voltage: 3.7V (Lithium-Ion)Capacity: 1800–3500 mAhChemistry Types: Alkaline, NiMH (Rechargeable), Lithium, Zinc-CarbonSize: Diameter ~14.5mm, Length ~50.5mmWeight: ~23g to 30g 1 YES 9.4 6DoF AR-VR Educational Controller can be used as and augmented reality (AR) device. Hold virtual heart, lungs, dinosaurs, plants and so much more in your hand to get an engaging learning experience. AR provides students with opportunities to deepen their knowledge within several areas, including:ScienceWorking with numbersSpatial concepts Content creationReal-life environments & scenarios 1 YES 9.5 Samsung Galaxy M15 5G or ARCore supported Devices Display: 6.5-inch Super AMOLED, 1080 x 2340 pixelsProcessor: MediaTek Dimensity 6100+, Octa-coreRAM & Storage: 4GB/6GB/8GB RAM, 28GB/256GB storage (expandable up to 1TB)Rear Cameras: 50MP (wide) + 5MP (ultra-wide) + 2MP (macro)Front Camera: 13MPBattery: 6,000mAh, 25W fast charging OS: Android 14 with One UI 6Security: Side-mounted fingerprint sensor Connectivity: 5G, NFC supportDimensions: 160.1 x 76.8 x 9.3mm, Weight : 217g 1 YES 9.6 VR Application Content for experintial learning a) VR chemistry lab, b) VR human anatomy, c) VR tour guide, d) VR English Learning App, e) VR space exploration app, f) VR electrical simulator app, g) VR Based Lathe Machine app, h) VR Based SMD Soldering & De soldering app 1 YES 10 Drone Kit Should Consist of Following Line Item. Drone Kit with Wi-Fi and Camera is an ideal project for enthusiasts looking to build a custom drone from the ground up. This kit typically includes essential components such as a frame, brushless motors (BLDC), electronic speed controllers (ESCs), a flight controller board (FCB), and a Wi-Fi-enabled camera for real-time video transmission. It offers the flexibility of adding a LiPo battery for power, a remote controller, and propellers for flight stability. With built-in WiFi, users can easily control and monitor the drone using a mobile app or computer, while the camera provides aerial photography and video streaming capabilities. 1 x F450 Frame 4 x 1000kv BLDC Motor 4 x ESC Motor 1 x 2-3 Cell Battery Charger1 x 2200 mAh Lipo Battery1 x Fly Sky FS-CT6B 6ch 2.4GHz Transmitter & Receiver1 x APM 2.8 Flight Controller (Without Compass) 1 YES 11.1 Mini Makers Pack Thermo Sage Thermo Sage is a touch-free temperature monitoring system, and the model should include an ESP8266, OLED display, infrared temperature sensor, ultrasonic sensor, two LEDs, and a buzzer for efficient health monitoring. When the ultrasonic sensor detects a person within 10 cm, the infrared sensor measures their body temperature, displaying the result on the OLED screen. If the temperature I normal, the green LED lights up as an indication. However, if the temperature exceeds the normal range, the red LED activates, and the buzzer sounds an alert. The design must feature a durable plastic body for reliable performance, offering a safe, contactless solution for monitoring body temperature, ideal for public health and safety applications. Microcontroller: ESP8266 for wireless connectivityDisplay: OLED screen for temperature readingsTemperature Sensor: Infrared sensor for touch-free measurementDistance Sensor: Ultrasonic sensor to detect person within 10 cmLED Indicators: Green LED for normal temperature, red LED for high temperatureBuzzer: Alerts when temperature is above normal rangeBody: Durable plastic for reliable performanceOne pair of PCB and Mechanical Design will be provided 11.2 Sun Quest Sun Quest model should include an Arduino Nano, two LDR modules, a servomotor, a solar panel, and two LEDs to maximize energy efficiency. The LDR modules detect light intensity, enabling the system to track the sun’s position. When one LDR senses higher light intensity, the servo motor should rotate the solar panel toward that direction to optimize energy capture. The LEDs connected to the solar panel will demonstrate real-time power generation, lighting up to show how current is produced as the panel adjusts. The design must feature a durable plastic body for longevity, enhancing solar energy efficiency by dynamically following the sun’s path throughout the day. Microcontroller: Arduino Nano for system controlLight Sensors: Two LDR modules for detecting light intensityActuator: Servo motor for rotating the solar panelSolar Panel: Generates and demonstrates power outputLED Indicators: Show real-time power generationBody: Durable plastic for longevity One pair of PCB and Mechanical Design will be provided 1 NO 11.3 LightScape Lightscape model should include an Arduino Nano, LDR module, IR sensor, and 6 LEDs to optimize energy usage based on environmental conditions. When the LDR detects darkness (indicating nighttime), the system should activate, keeping 3 LEDs ON for basic lighting. When the IR sensor detects movement, all 6 LEDs should turn ON for 5 seconds to enhance visibility for pedestrians or vehicles, then return to 3 LEDs ON. During daylight, when the LDR senses light, the LEDs should remain OFF to conserve energy. The design must feature a durable plastic body for reliability, providing efficient, adaptive street lighting that responds to both time of day and movement, significantly improving energy conservation and safety on the streets. Microcontroller: Arduino Nano for system automationSensors: LDR for detecting light levels, IR sensor for motion detectionLEDs: 6 LEDs for adaptive street lightingLighting Control: 3 LEDs ON at night, all 6 ON when motion is detected for 5 secondsEnergy Conservation: LEDs OFF during daylight Body: Durable plastic for reliabilityOne pair of PCB and Mechanical Design will be provided 1 NO 11.4 Navwave NavWave is a sonar-inspired object detection sDesign will be provided 12 Electronics & Hardware Kit Universal Electrical/Electronic breadboard plug and play training kit designed to perform the experiments from the basic to advance level of electrical and electronics exercises, This kit is made easy to conduct experiments by plugging in the components in to the specifically designed breadboard. Should have built-in Function generator, power supply and required meters List of components Resistors SetPotentiometers Non-linear resistors VDR-, LDR-, NTC-, PTC resistors Capacitors SetTransformer 1 NO 13.1 Experiential Skilling Lab set Electrical Booth Spec - 01 Each workstation should have dimensions of 4 ft width and 6 ft height. The material used for the workstations construction must be high-quality plywood with a thickness of at least 10mm, ensuring durability and stability. The workstation should be designed in a plus-shaped configuration, where each arm of the plus symbol represents an individual training domain. The work station should have 4 station where, Electrical installation, Plumbing and CCTV installation can be practiced All necessaries aids for this training should be provided in this work station 1 NO 13.2 CCTV Installation kit To provide a comprehensive training setup for students to learn and practice the installation, configuration, and maintenance of CCTV systems, including cabling, DVR setup, and network integration for monitoring and recording. Dome Cameras –1 NoBullet Camera-1 NoDVR/NVR Unit -1 No Cables and AccessoriesPower Supply with adaptorsSwitch and RouterDisplay and MonitoringNetworking Tools 1 NO 13.3 Domestic Electric Wiring Kit To provide a comprehensive training setup for students to learn and practice the installation, wiring, and maintenance of domestic Electric wiring methods, includes reading and understanding electrical drawings, Switch gears and colour coding of cables. Domestic electric wiring kit – 1 set MCB, 4P, 25ADistribution Box 3 tier 36 modules RCCB 2P 40A 30mA ACtypeMCB xC60 1P 2A C 10000A6A 1-WAY SWITCH 6A 2-way Switch6A/16A 3-Pin Socket Outlet PVC Casing-Capping, 50mmPVC CasingCapping, 25mmPVC Conduit, High density, 19mmSaddles, 19 mmPOP screwPVC Junction Box 19mm, 1 wayPVC Junction Box 19mm, 2 wayPVC Junction Box 19mm, 3 wayPVC Junction Box 19mm, 4 wayBatten Holder2- Module Box with surface plate, PVC4-Module Box, PVC8-Module Box, PVCTools – 1 set 12V Cordless Drill machinePhilip bit Spirit Level, 30 cm Steel Rule, 30 Cm Wire Stripper Heavy duty cable cutter Try square Measurement tape Mini Hack Saw frame with blades Hack Saw Frame with blades Crimping tool, tube type lugs File Set Electrician knifeAllen key set Hole saw, 22 mm Screw Driver set Nose plier Drill Bit Set Mini screw driver set Aluminum Stair Case, 3 step 1 NO 13.4 Plumbing Installation Setup To equip a plumbing training lab with all necessary tools and equipment to provide students with hands-on experience in basic and advanced plumbing techniques, including pipe fitting, jointing, fixture installation, and system testing. Tools for Pipe Cutting and ShapingPipe Cutter:Hacksaw:Pipe Bender:PVC Pipe Cutting Scissors:Tools for Threading and JoiningPipe Threaded Set: Teflon Tape Dispenser:Plumbers Soldering Kit:Adhesive Application Kit: Wrenches and SpannersAdjustable Pipe Wrench:Basin Wrench:Ring Spanner Set:Testing and Measurement ToolsWater Pressure Gauge: Flow Rate Meter:Leak Detection Kit: Spirit Level:Plumbing Fixtures for Installation PracticeSink and Basin Fixtures:Faucets and Taps:Shower Unit: Drainage System ComponentsP-traps and S-traps:Wastewater Pipes:Junction Boxes: 1 NO 14 Smart Solar Renewable Energy Kit Solar Photovoltaic Training Kit for Lab experimentsPV Module Stand: 2nos. 1 NO 35 15 SAM S-5 Missile Educational Training Kit Missile defense systems are essential for national security, airspace protection, and strategic deterrence. This will explore the working principles of the missile system, focusing on its launch mechanism, guidance technology, and interception capabilities. Additionally, it will analyze the applications of the model in air defense, including target tracking, threat neutralization, and military strategy. SAM S-5 Missile System should consist of the following items. Raspberry Pi x 1Camera Module x 1Lidar or Ultrasonic sensor x 1 Servo MotorsGyroscope x 1Shooter x 1Battery x 1 Battery Adapter x 1 1 NO 16 GEO Satellite Communication Educational Training Kit Satellites play a crucial role in modern communication, navigation, weather forecasting, and scientific research. This will explore the communication and data transmission process in GEO satellites analyze the applications of GEO satellites in telecommunications, weather forecasting, and remote sensing. GEO Satellite Communication Kit should consist of the following items. Raspberry Pi x 3ESP8266 x 3ZigBee Module and adapter x 3 RF Module x 3 Temperature and Humidity Sensor x 2 Soil Moisture Sensor x 1 NPK Sensor x 1 Pressure Sensor x 2Co2 Sensor x 1Camera Module x 1Buzzer x 3 LEDsRover Model x 1Base station Model x 1Battery Battery Adapter 1 NO 17 LUNAR PATH Explorer- Educational Rover BOT It should comes with Matt finished metal chassis. Included all sensor metal clamps, and high torque DC Johnson A grade motors. Compatible with Arduino, raspberry, etc. Easy to assemble. Assembly manual provided in the kit. All required components, sensors, and tools are provided in the kit. It should consists of following items: 12V DC 10 RPM MOTORS -2ULTRASONIC SENSORS - 3IR SENSORS - 5 WIDE TRACK WHEELS - 4WIDE TRACK BELTNUT BOLTSSPANNER TWO IN ONE SCREWDRIVER,JUMPER WIRESSG90 SERVO MOTOR -1 ON/OFF ROCKER SWITCH -2TOGGLE SWITCH - 2MOTOR WIRES 1 NO 18 Package No. 1 Atal Tinkering Lab The package should include all items As per QR/specification for Package No. 1 - Atal Tinkering Lab of NITI AAYOG Electronics Development, Robotics, Internet of Things and Sensors approved by NITI AAYOG (Approved Copy of Qrs / Specification uploaded in Gem portal) Specification: Microcontrollers & Boards:Arduino Uno/Nano/Mega (or equivalents).Raspberry Pi 3 Model B+.ESP32, Node MCU.Prototyping Tools:Solderless breadboards (400 and 800 pins).Self-adhesive proto shield and FR2 A-grade materials.Hook-up wires, jumper cables (M-M, M-F, F-F), and alligator connectors.Sensors & Modules:Wide range of sensors: Humidity, temperature, motion, gas (MQ series), IR, ultrasonic, PIR, and more.RFID Reader, Bluetooth, GSM, GPS, and Wi-Fi modules.Capacitive touch, soil moisture, rain, and color recognition sensors.Displays & Actuators:16x2 LCD display with I2C interface. LED matrices, RGB LEDs, and various single-color LEDs.Motors: DC, stepper, servo, vibrating, and BO motor with driver modules.Miscellaneous Components: Resistor and capacitor kits, diodes, transistors, and ICs (LM555).Relays, motor drivers, and piezoelectric plates.Robotics, drone, and application-specific DIY kitsPower & Connectivity:USB cables, battery packs, power banks, and clips. 1 YES 19 Package No. 2 Atal Tinkering Lab – Rapid Prototyping Tools The Package should include all items As per QR/specification for Package No.2 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specifications: 3D Printer Kit and tools Dedicated UPS/Power back up Filament for 3D printer Filament Storage Box Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materials 1 YES 20 Package No. 3 Atal Tinkering Lab – Mechanical, Electrical and Measurement Tools The package should include all items As per QR/specification for Package No.3 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI 1 YES 36 AAYOG Specification: Cutting Tools: Hacksaw frame with blades (standard & mini).File set, mini file set, and flexible cutting mat. Hand Tools: Pliers (4.5-inch), tweezers, ball pein hammer, claw hammer, C-clamp, spanner set, Allen key set, wrench, and wire strippers. Drilling Tools: Drill machine set with workstation.Drill bit set and vice (normal). Screwdrivers & Soldering Tools: Precision screwdriver set, electric screwdriver set, soldering kit, and soldering helping hand. Measuring & Testing Tools: Digital multi meter, digital Vernier caliper, spirit level, measuring tape, and pen electric tester. Digital oscilloscope, adapters, telescope, DIY paper microscope Power Tools: Cordless rotary multi tool, dual-temperature heat gun, air blower, and hot glue gun.Organization & Workspace: Plastic trays, pegboard, and return measuring tools 21 Intel Core i5 - 1245U Mid Level Laptop - Notebook Specification: Laptop Type: Mid LevelIntel Core i5 - 1245UOperating System (Factory PreLoaded)Window 11 HomeRAM Size (GB)16Display Size (in cm) – Diagonal: 35.56 to 38.09 (14 In to 14.99 In)Capacity of Storage Drive (in GB)512 1 YES 22 65 Inch Display Interactive Panel with CPU Size (Diagonal): 65 or higher Panel Technology: IPS / VA Resolution: (Minimum) 4K (3840 x 2160) Viewing Angle (Hx V): 178*178RAM: 4 GB or higher On-board memory: 32 GB or higher Input (Minimum): 3 x HDMI, 4 x USB (Out of, which min 2xUSB3.0),1 xAudio, 1 x OPS slot, 1 x USB Type C Port Output: (Minimum) 1 x HDMI, 1 x Audio The software enables teachers to generate presentations using Al in PPT or PDF format. The teachers can select their Class, Subject, Topic and language to generate the presentations. The software supports all Indian and Global languages including English, Hindi, Marathi, Kannada, Tamil, Telugu, Gujarati, etc. Using Al, the software is able to analyse the Class and Subject and generate output accordingly. Using the Ask Me Anything tool, the teachers can search queries related to any topic and the Al is able to generate Class-wise and Subject-wise results including Images, Videos (YouTube Videos) and Explanation. Connected Classroom Software has in-built Generative Al capability to search and import filtered content relevant to Class and Subject. - images, videos, explanation for queries given by teachers in all languages. Teachers are able to import images and videos for teaching in class. The software has a text-to-speech function (for all languages) to convert text-based explanation into speech and read out loud in class. Software has Two-Way Live Conferencing Feature with education specific features Live conferencing feature also enables recording which gets directly uploaded to cloud.. Reports: Detailed reports for Attendance, Assessments, Study Material, are available for administrators to access. Administrators should be able to access to view the whiteboard saved by the teachers and monitor the usage.. Below tools and simulations are provided for enhancing the teaching-learning experience: - Graph: Demonstrating equations using 2D and 3D visualizations - Calculator: Standard and scientific - PHET simulation library with 100+ simulations across Maths, Physics, Chemistry, Biology. 1 YES 23 2 kVA OFF LINE UPS Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 1 YES 24 Battery 75/80 AH capacity Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 1 YES 25 6Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 NO 37 26 8 Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 NO 27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire with switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch 1 NO 28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire without switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 1 NO 29 1.5 mm2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 NO 30 Fans : 48 Sweep (1200 mm) Regular model Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 1 NO 31 LED Down Light 15-18W Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 1 NO 32 Fall Ceiling for Innovation lab to cover entire Area Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. 1 NO 33 Floor Mat for Innovation lab to Cover the entire Lab Providing and laying linoleum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications 1 NO 34 Repair and Replacement of Windows and Doors (if required) Repairing door and window frames with available wood to the required size. 1 NO 35 Painting Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² 1 NO 38 with paint of approved quality to give an even shade, after thoroughly rooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-ccharge. (The gloss should be 50% @ 60 degree angle with 10 years life) 36 Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete.(P No.59, SI.No 9.1 PWD SR 2023-24 Volume 2) 1 NO 37 Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification.( SI.No 8.33.1 PWD SR 2023-24 Volume 2) 1 NO 38 Polyurethane based ingle Component for Existing surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification (P No.A-149, SI.No 15.2 PWD SR 2023-24 Volume 1) 1 NO 39 Model Table - Modular Table with MDF Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface not to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 1 NO 40 Student Table - Modular Table with Particle Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to 1 NO 39 be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface not to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). 41 Trainer Table - Executive Table with Pedestal, 3 Side Storage Unit 1 NO 42 Student Chair – Providing and supplying Unbranded wood chair/stool, already assembled Technical Specifcation Chair feature painting. Color-Other, Style Traditional. Furniture Assembly Already Assembled. Material Wood. Additional Parameters Additional Features good quality wooden arm chairs. 1 NO 43 Trainer Chair - Revolving Chair with Synchronic tilt mechanism 1 NO 44 Training of Teachers The Master Trainer will conduct a 2-day Training of Trainers (ToT) program for educators on effectively utilizing the Innovation Lab . The training should cover hands-on learning methodologies, STEM education, and practical applications of lab tools and technologies (P No.A-48, SI.No 1 PWD SR 2023-24 Volume 1) 1 NO 45 Technical Support 1 NO Schedule II Paystem, and the model should include an ESP8266, OLED display, ultrasonic sensor, and servo motor to detect and display nearby objects. The ultrasonic sensor, mounted on the servo motor, should continuously rotate from 0 to 180 degrees, scanning the surroundings for obstacles. As objects are detected, the system should display a dotted pattern on the OLED screen, similar to a submarine radar interface, providing a real-time visual representation of object proximity and location. The design must feature a durable plastic body for reliability, simulating sonar navigation and offering a dynamic way to monitor nearby obstacles through the rotating ultrasonic sensor and radar-like display. Its robust design ensures optimal performance in various environments, making it an excellent tool for obstacle detection and navigation. •Microcontroller: ESP8266 for processing and wireless capabilityDisplay: OLED screen with radar-like visual representationSensor: Ultrasonic sensor for object detectionActuator: Servo motor for 0°-180° scanning motionDetection Mechanism: Real-time scanning and obstacle mappingBody: Durable plastic for reliabilityOne pair of PCB and Mechanical
Contract Date: Ref. Documents Contract Value : 53.88 Lakh
Government Departments No of Bidders 1
45.
Housing Urban and Rular Development #8768080 AOC
Providing, Supplying, Commissioning Of Innovation Lab Equipments For Ghps & Ghs Sindhavala Village In Ballari Taluk, Under 2515 Kkrdb Cmdq For The Year 2024-25. - Misc.,Gst18%-1 Six Axis Robotic ARM Consists of •Axis – 6 axis•64- bit ARM Cortex Processor8GB RAM64 GB Storage CapacityServo Motors with 9.6 Kg/cm Torque Payload – 200gReach – 200 mmUSB Support port Should have 8 MP Camera User can add various objects for detection Should identify pre trained Objects Should perform pick and place operation Dimension in mm(D x H): 1100 x 600 One pair of PCB and Mechanical casing should be provided 2 Petro robot it should consists of Should have 8 MP Camera 64 bit ARM Cortex Processor 2-D Lidar Sensor Person RecognitionObject Recognition Should consists of 4 leg armShould perform forward and reverse motion Should have rechargeable battery Should have 12 V rechargeable BatteryPower Adapter for Battery Recharge •Dimension in cm (L x W x H): 62 x 20 x 45•One pair of PCB and Mechanical casing should be provided •Tasks performed: 1. Walking2. Running3. Pushups4. Dance5. Jumping6. Sit and Stand positions7. Lane following 3 Line Following robo car it should consists of A Robotic car with 4 wheelsShould have 2 IR sensors Should have 4 DC motors Atmega 328P Microcontroller L298 Motor Driver for Direction and Speed control Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5 Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: Straight Weight: 250gm•One pair of PCB and Mechanical casing should be provided 4 Obstacle avoidance robo car it shouldconsists of Robotic Car with 4 Wheels Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8 Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided 5 Voice controlled Robo Car it should consists of Robotic Car with 4 Wheels DC motors with drivesBluetooth controller• Should perform motions by voice command Ultrasonic Sensors4 DC motors with drive ESP32 controller Dimension (L x W x H): 70 x 19 x 22 mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg- Cm): 0.8Gearbox Shape: Straight Weight: 250gm •One pair of PCB and Mechanical casing should be provided RC Tank Robot RC Tank Chassis Kit – 01ESP32 controllerLED Switch4 DC motors with Drive Battery 4 DC motors with drive ESP32 controllerDimension (L x W x H): 70 x 19 x 22mmShaft Length (mm): 8.5Shaft Diameter (mm): 5.4mm-(round side) and 3.5mm-(flat side)Rated Torque (Kg-Cm): 0.8Gearbox Shape: StraightWeight: 250gm•One pair of PCB and Mechanical casing should be provided AI Humanoid Robot The AI Humanoid robot can realize human body induction in different directions, can perform facial recognition, supports voice interaction, and can realize the function of guiding navigation and explaining. Should have obstacle avoidance algorithm, perceive the real-time changes in the surrounding environment, bypass the obstacles in the planned path, and choose the appropriate route Go forward and finally reach the target point. The robot should have a touchable high-definition display screen, which should display, video playback, product information query, map display and other functions. The robot should have an open SDK package and an open API, which can be used for development according to the application scenario, adding exclusive personality functions, and more in line with the actual application scenario. Technical specifications include a user-friendly interface, robust security measures, seamless integration, efficient performance, and scalability. Specification: Processor: Intel i5 8th Gen Motors: DC motors for smooth and precise movement.Microphone: High-sensitivity microphone for voice recognition and interaction.Speakers: High-quality speakers for audio output and ntertainment. Display: LCD display for user interaction, information visualization. Dimension in cm(L x W x H): 50 x 54 x 100 IoT Pack IoT Based Smart Agriculture Smart Agriculture model should include an Raspberry Pi, a 10 inch LCD display, soil moisture sensor, water pump, and relay to automate irrigation for plants. The soil moisture sensor should continuously monitor the moisture levels in the soil. When the soil is wet, the relay should remain off, preventing the pump from operating. However, when the soil moisture level drops and becomes dry, the relay should activate, turning on the water pump to irrigate the soil. The LCD display should provide real-time feedback on soil moisture levels, ensuring efficient water management and promoting healthy plant growth. Constructed with a durable plastic body for resilience, this project demonstrates the effectiveness of smart technology in modern agriculture, optimizing water usage and enhancing crop health while ensuring reliable performance in various environmental conditions. Microcontroller: Raspberry piSoil Moisture Sensor – Measures soil humidity levels.DHT11/DHT22 Sensor – Monitors temperature and humidity.pH Sensor – Checks soil acidity or alkalinity.LDR (Light Sensor) – Detects sunlight intensity.Rain Sensor – Detects rainfall for irrigation control.Ultrasonic Sensor – Monitors water level in tanks.Water Pump – Automated irrigation control via relay.Servo Motor – Adjusts solar panel orientation.Relay Module (5V) – Controls high-power devices.IoT Connectivity – Data transmission via WiFi/Bluetooth.Cloud Storage – Stores real-time sensor data online.Web App – Displays real-time farm conditions.Power Adapter – Powers all connected components. IoT Based Home Automation The Home Automation System model should include a Raspberry Pi, MQ-2 gas sensor, buzzer, ultrasonic sensor, servo motor, 7-inch display, DHT11 temperature sensor, and two relays to enhance home convenience and safety. The ultrasonic sensor should detect approaching objects, triggering the servo motor to automatically open the door, while the 7-inch display presents real-time temperature readings. In one room, an IR sensor should detect motion, activating the relay to turn on an LED and a fan. Additionally, when the MQ-2 sensor detects smoke in the kitchen, the buzzer should sound an alert until the smoke dissipates. The system must feature a durable plastic body for reliability and easy assembly, showcasing the seamless integration of smart technologies to create a safer and more efficient living environment, ensuring enhanced convenience and security. Microcontroller: Raspberry Pi for central control with WiFi and Bluetooth Ram: 4GB64 bit ARM Cortex ControllerGas Detection: MQ-2 sensor to detect smoke and gas leaksAlert System: Buzzer sounds when smoke is detected• Object Detection: Ultrasonic sensor detects approaching objects for automatic door controlDoor Mechanism: Servo motor opens the door upon object detection• Display: 7-inch screen for real-time temperature and system statusTemperature Monitoring: DHT11 sensor measures room temperature and humidityMotion Detection: IR sensor detects movement in the room Relay Module (x2): Controls LED and fan activationLighting & Ventilation: LED and fan turn on when motion is detectedBody: Durable plastic for reliability and easy assembly 8.3 Smart Watch health parameter monitoring kit Smart Watch is an innovative wearable device project, and the model should include an ESP processor, OLED display, and four push buttons to provide a range of functionalities. The watch must feature a custom-designed PCB for compactness and efficiency, along with a durable watch belt for comfortable wear. One push button should be dedicated to displaying the current time, date, and day, while another button should provide weather information, enhancing convenience for users. The remaining two buttons should be integrated for the IoT interface, allowing interaction with various smart devices and applications. This project demonstrates the potential of combining advanced technology with practical design, creating a multifunctional smartwatch that caters to modern lifestyle needs, ensuring reliability and user-friendly operation. ESP Processor – Core controller for smartwatch operations. OLED Display – Displays time, date, weather, and IoT interactions. Four Push Buttons – Dedicated for time, date, weather, and IoT control. Custom-Designed PCB – Ensures compactness and efficiency. Durable Watch Belt – Provides comfort for daily wear. Time, Date, and Day Display – Activated by a dedicated button. Weather Information Display – Accessed via a separate button. IoT Integration – Controls and interacts with smart devices. Energy-Efficient Design – Optimized for long battery life. Modern & User-Friendly – Enhances convenience and usability. 8.4 IoT Based Smart Cam Vision Snap should consist of an advanced security system that includes facial recognition for identifying individuals, enhancing security in restricted areas. Key components include a Raspberry Pi, a camera, and a display for real-time monitoring. This system features motion detection, which triggers alerts for unauthorized movement, significantly improving surveillance capabilities. It provides real-time alerts, enabling immediate responses to potential threats, while secure connectivity ensures the protection of sensitive data. Together, these features create a robust security solution for various applications, making Vision Snap an effective tool for safeguarding premises and enhancing overall security measures. Raspberry Pi – Central processing unit for AI-based security.Camera Module – Captures real-time footage and facial recognition.Display Screen – Shows live monitoring and alerts.Facial Recognition – Identifies individuals for security access.Motion Detection – Detects unauthorized movement and triggers alerts.• Real-Time Alerts – Sends notifications for immediate response.Secure Connectivity – Protects sensitive surveillance data.AI-Powered Surveillance – Enhances monitoring efficiency.Remote Access – Allows monitoring from any location.Robust Security System – Ideal for restricted areas and premises. Immersive Technology Pack VR Headset Kit Should Consist of Following Line Item VR Head Set Storage: 512GBDisplay: Each eye experiences a resolution of 2064 x 2208 pixels, delivering sharp and immersive visuals.Processor: Powered by the Snapdragon XR2 Gen 2 chipset, providing enhanced performance for demanding VR applications.Refresh Rate: Supports a 120Hz refresh rate, ensuring smooth and responsive gameplay.Memory: Equipped with 8GB of RAM to handle multitasking and complex VR environments.Mixed Reality Capabilities: Features full-color passthrough, allowing users to blend virtual and real-world elements seamlessly.Design: Utilizes pancake optics to reduce the headsets size, offering a more comfortable fit for extended use. 32-inch or more smart LED TV to Stream a VR applications Resolution: HD (720p)Smart Platform: Google TVFeatures: Google Play, Google Cast Built-in, HDR10, Dolby Audio, Voice Remote, Live TV Streaming AA Batteries – 10 Voltage: 3.7V (Lithium-Ion)Capacity: 1800–3500 mAhChemistry Types: Alkaline, NiMH (Rechargeable), Lithium, Zinc-CarbonSize: Diameter ~14.5mm, Length ~50.5mmWeight: ~23g to 30g 6DoF AR-VR Educational Controller can be used as and augmented reality (AR) device. Hold virtual heart, lungs, dinosaurs, plants and so much more in your hand to get an engaging learning experience. AR provides students with opportunities to deepen their knowledge within several areas, including:ScienceWorking with numbersSpatial concepts Content creationReal-life environments & scenarios Samsung Galaxy M15 5G or ARCore supported Devices Display: 6.5-inch Super AMOLED, 1080 x 2340 pixelsProcessor: MediaTek Dimensity 6100+, Octa-coreRAM & Storage: 4GB/6GB/8GB RAM, 28GB/256GB storage (expandable up to 1TB)Rear Cameras: 50MP (wide) + 5MP (ultra-wide) + 2MP (macro)Front Camera: 13MPBattery: 6,000mAh, 25W fast charging OS: Android 14 with One UI 6Security: Side-mounted fingerprint sensor Connectivity: 5G, NFC supportDimensions: 160.1 x 76.8 x 9.3mm, Weight : 217g VR Application Content for experintial learning a) VR chemistry lab, b) VR human anatomy, c) VR tour guide, d) VR English Learning App, e) VR space exploration app, f) VR electrical simulator app, g) VR Based Lathe Machine app, h) VR Based SMD Soldering & De soldering app Drone Kit Should Consist of Following Line Item. Drone Kit with Wi-Fi and Camera is an ideal project for enthusiasts looking to build a custom drone from the ground up. This kit typically includes essential components such as a frame, brushless motors (BLDC), electronic speed controllers (ESCs), a flight controller board (FCB), and a Wi-Fi-enabled camera for real-time video transmission. It offers the flexibility of adding a LiPo battery for power, a remote controller, and propellers for flight stability. With built-in Wi- Fi, users can easily control and monitor the drone using a mobile app or computer, while the camera provides aerial photography and video streaming capabilities. 1 x F450 Frame 4 x 1000kv BLDC Motor 4 x ESC Motor 1 x 2-3 Cell Battery Charger1 x 2200 mAh Lipo Battery1 x Fly Sky FS-CT6B 6ch 2.4GHz Transmitter & Receiver1 x APM 2.8 Flight Controller (Without Compass) Mini Makers Pack Thermo Sage Thermo Sage is a touch-free temperature monitoring system, and the model should include an ESP8266, OLED display, infrared temperature sensor, ultrasonic sensor, two LEDs, and a buzzer for efficient health monitoring. When the ultrasonic sensor detects a person within 10 cm, the infrared sensor measures their body temperature, displaying the result on the OLED screen. If the temperature is normal, the green LED lights up as an indication. However, if the temperature exceeds the normal range, the red LED activates, and the buzzer sounds an alert. The design must feature a durable plastic body for reliable performance, offering a safe, contactless solution for monitoring body temperature, ideal for public health and safety applications. Microcontroller: ESP8266 for wireless connectivityDisplay: OLED screen for temperature readingsTemperature Sensor: Infrared sensor for touch-free measurementDistance Sensor: Ultrasonic sensor to detect person within 10 cm• LED Indicators: Green LED for normal temperature, red LED for high temperatureBuzzer: Alerts when temperature is above normal range• Body: Durable plastic for reliable performanceOne pair of PCB and Mechanical Design will be provided Sun Quest Sun Quest model should include an Arduino Nano, two LDR modules, a servomotor, a solar panel, and two LEDs to maximize energy efficiency. The LDR modules detect light intensity, enabling the system to track the sun’s position. When one LDR senses higher light intensity, the servo motor should rotate the solar panel toward that direction to optimize energy capture. The LEDs connected to the solar panel will demonstrate real-time power generation, lighting up to show how current is produced as the panel adjusts. The design must feature a durable plastic body for longevity, enhancing solar energy efficiency by dynamically following the sun’s path throughout the day. Microcontroller: Arduino Nano for system controlLight Sensors: Two LDR modules for detecting light intensityActuator: Servo motor for rotating the solar panelSolar Panel: Generates and demonstrates power outputLED Indicators: Show real-time power generationBody: Durable plastic for longevity One pair of PCB and Mechanical Design will be provided LightScape Lightscape model should include an Arduino Nano, LDR module, IR sensor, and 6 LEDs to optimize energy usage based on environmental conditions. When the LDR detects darkness (indicating nighttime), the system should activate, keeping 3 LEDs ON for basic lighting. When the IR sensor detects movement, all 6 LEDs should turn ON for 5 seconds to enhance visibility for pedestrians or vehicles, then return to 3 LEDs ON. During daylight, when the LDR senses light, the LEDs should remain OFF to conserve energy. The design must feature a durable plastic body for reliability, providing efficient, adaptive street lighting that responds to both time of day and movement, significantly improving energy conservation and safety on the streets. Microcontroller: Arduino Nano for system automationSensors: LDR for detecting light levels, IR sensor for motion detectionLEDs: 6 LEDs for adaptive street lightingLighting Control: 3 LEDs ON at night, all 6 ON when motion is detected for 5 secondsEnergy Conservation: LEDs OFF during daylight Body: Durable plastic for reliabilityOne pair of PCB and Mechanical Design will be provided Navwave NavWave is a sonar-inspired object detection system, and the model should include an ESP8266, OLED display, ultrasonic sensor, and servo motor to detect and display nearby objects. The ultrasonic sensor, mounted on the servo motor, should continuously rotate from 0 to 180 degrees, scanning the surroundings for obstacles. As objects are detected, the system should display a dotted pattern on the OLED screen, similar to a submarine radar interface, providing a real-time visual representation of object proximity and location. The design must feature a durable plastic body for reliability, simulating sonar navigation and offering a dynamic way to monitor nearby obstacles through the rotating ultrasonic sensor and radar-like display. Its robust design ensures optimal performance in various environments, making it an excellent tool for obstacle detection and navigation. •Microcontroller: ESP8266 for processing and wireless capabilityDisplay: OLED screen with radar-like visual representationSensor: Ultrasonic sensor for object detectionActuator: Servo motor for 0°-180° scanning motionDetection Mechanism: Real-time scanning and obstacle mappingBody: Durable plastic for reliabilityOne pair of PCB and MechanicalDesign will be provided Electronics & Hardware Kit Universal Electrical/Electronic breadboard plug and play training kit designed to perform the experiments from the basic to advance level of electrical and electronics exercises, This kit is made easy to conduct experiments by plugging in the components in to the specifically designed breadboard. Should have built-in Function generator, power supply and required meters List of components Resistors SetPotentiometers Non-linear resistors VDR-, LDR-, NTC-, PTC resistors Capacitors SetTransformer 1 Experiential Skilling Lab set Electrical Booth Spec - 01 Each workstation should have dimensions of 4 ft width and 6 ft height. The material used for the workstations construction must be high-quality plywood with a thickness of at least 10mm, ensuring durability and stability. The workstation should be designed in a plus-shaped configuration, where each arm of the plus symbol represents an individual training domain. The work station should have 4 station where, Electrical installation, Plumbing and CCTV installation can be practiced All necessaries aids for this training should be provided in this work station 1 CCTV Installation kit To provide a comprehensive training setup for students to learn and practice the installation, configuration, and maintenance of CCTV systems, including cabling, DVR setup, and network integration for monitoring and recording. Dome Cameras –1 NoBullet Camera-1 NoDVR/NVR Unit -1 No Cables and AccessoriesPower Supply with adaptorsSwitch and RouterDisplay and MonitoringNetworking Tools 1 Domestic Electric Wiring Kit To provide a comprehensive training setup for students to learn and practice the installation, wiring, and maintenance of domestic Electric wiring methods, includes reading and understanding electrical drawings, Switch gears and colour coding of cables. Domestic electric wiring kit – 1 set MCB, 4P, 25ADistribution Box 3 tier 36 modules RCCB 2P 40A 30mA ACtype• MCB xC60 1P 2A C 10000A6A 1-WAY SWITCH 6A 2-way Switch• 6A/16A 3-Pin Socket Outlet PVC Casing-Capping, 50mmPVC Casing- Capping, 25mmPVC Conduit, High density, 19mmSaddles, 19 mmPOP screwPVC Junction Box 19mm, 1 wayPVC Junction Box 19mm, 2 wayPVC Junction Box 19mm, 3 wayPVC Junction Box 19mm, 4 wayBatten Holder2- Module Box with surface plate, PVC4-Module Box, PVC8-Module Box, PVCTools – 1 set 12V Cordless Drill machinePhilip bit Spirit Level, 30 cm Steel Rule, 30 Cm Wire Stripper Heavy duty cable cutter Try square Measurement tape Mini Hack Saw frame with blades Hack Saw Frame with blades Crimping tool, tube type lugs File Set Electrician knifeAllen key set Hole saw, 22 mm Screw Driver set Nose plier Drill Bit Set Mini screw driver set Aluminum Stair Case, 3 step 1 Plumbing Installation Setup To equip a plumbing training lab with all necessary tools and equipment to provide students with hands-on experience in basic and advanced plumbing techniques, including pipe fitting, jointing, fixture installation, and system testing. Tools for Pipe Cutting and ShapingPipe Cutter:Hacksaw:Pipe Bender:PVC Pipe Cutting Scissors:Tools for Threading and JoiningPipe Threaded Set: Teflon Tape Dispenser:Plumbers Soldering Kit:Adhesive Application Kit: Wrenches and SpannersAdjustable Pipe Wrench:Basin Wrench:Ring Spanner Set:Testing and Measurement ToolsWater Pressure Gauge: Flow Rate Meter:Leak Detection Kit: Spirit Level:Plumbing Fixtures for Installation PracticeSink and Basin Fixtures:Faucets and Taps:Shower Unit: Drainage System ComponentsP-traps and S-traps:Wastewater Pipes:Junction Boxes: 1 Smart Solar Renewable Energy Kit Solar Photovoltaic Training Kit for Lab experimentsPV Module Stand: 2nos. 1 SAM S-5 Missile Educational Training Kit Missile defense systems are essential for national security, airspace protection, and strategic deterrence. This will explore the working principles of the missile system, focusing on its launch mechanism, guidance technology, and interception capabilities. Additionally, it will analyze the applications of the model in air defense, including target tracking, threat neutralization, and military strategy. SAM S-5 Missile System should consist of the following items. Raspberry Pi x 1Camera Module x 1Lidar or Ultrasonic sensor x 1 Servo MotorsGyroscope x 1Shooter x 1Battery x 1 Battery Adapter x 1 GEO Satellite Communication Educational Training Kit Satellites play a crucial role in modern communication, navigation, weather forecasting, and scientific research. This will explore the communication and data transmission process in GEO satellites analyze the applications of GEO satellites in telecommunications, weather forecasting, and remote sensing. GEO Satellite Communication Kit should consist of the following items. Raspberry Pi x 3ESP8266 x 3ZigBee Module and adapter x 3 RF Module x 3 Temperature and Humidity Sensor x 2 Soil Moisture Sensor x 1 NPK Sensor x 1 Pressure Sensor x 2Co2 Sensor x 1• Camera Module x 1Buzzer x 3 LEDsRover Model x 1Base station Model x 1Battery Battery Adapter LUNAR PATH Explorer- Educational Rover BOT It should comes with Matt finished metal chassis. Included all sensor metal clamps, and high torque DC Johnson A grade motors. Compatible with Arduino, raspberry, etc. Easy to assemble. Assembly manual provided in the kit. All required components, sensors, and tools are provided in the kit. It should consists of following items: 12V DC 10 RPM MOTORS -2ULTRASONIC SENSORS - 3IR SENSORS - 5 WIDE TRACK WHEELS - 4WIDE TRACK BELTNUT BOLTSSPANNER TWO IN ONE SCREWDRIVER,JUMPER WIRESSG90 SERVO MOTOR -1 ON/OFF ROCKER SWITCH -2TOGGLE SWITCH - 2MOTOR WIRES Package No. 1 Atal Tinkering Lab The package should include all items As per QR/specification for Package No. 1 - Atal Tinkering Lab of NITI AAYOG Electronics Development, Robotics, Internet of Things and Sensors approved by NITI AAYOG (Approved Copy of Qrs / Specification uploaded in Gem portal) Specification: Microcontrollers & Boards:Arduino Uno/Nano/Mega (or equivalents).• Raspberry Pi 3 Model B+.ESP32, Node MCU.Prototyping Tools:Solderless breadboards (400 and 800 pins).Self-adhesive proto shield and FR2 A-grade materials.Hook-up wires, jumper cables (M-M, M-F, F-F), and alligator connectors.Sensors & Modules:Wide range of sensors: Humidity, temperature, motion, gas (MQ series), IR, ultrasonic, PIR, and more.RFID Reader, Bluetooth, GSM, GPS, and Wi-Fi modules.Capacitive touch, soil moisture, rain, and color recognition sensors.Displays & Actuators:16x2 LCD display with I2C interface. LED matrices, RGB LEDs, and various single-color LEDs.Motors: DC, stepper, servo, vibrating, and BO motor with driver modules.Miscellaneous Components: Resistor and capacitor kits, diodes, transistors, and ICs (LM555).Relays, motor drivers, and piezoelectric plates.Robotics, drone, and application-specific DIY kitsPower & Connectivity:USB cables, battery packs, power banks, and clips. Package No. 2 Atal Tinkering Lab – Rapid Prototyping Tools The Package should include all items As per QR/specification for Package No.2 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specifications: 3D Printer Kit and tools Dedicated UPS/Power back up Filament for 3D printer Filament Storage Box Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materials Package No. 3 Atal Tinkering Lab – Mechanical, Electrical and Measurement Tools The package should include all items As per QR/specification for Package No.3 - Atal Tinkering Lab of NITI AAYOG Rapid Prototyping Tools approved by NITI AAYOG Specification: Cutting Tools: Hacksaw frame with blades (standard & mini).File set, mini file set, and flexible cutting mat. Hand Tools: Pliers (4.5-inch), tweezers, ball pein hammer, claw hammer, C-clamp, spanner set, Allen key set, wrench, and wire strippers. Drilling Tools: Drill machine set with workstation.Drill bit set and vice (normal). Screwdrivers & Soldering Tools: Precision screwdriver set, electric screwdriver set, soldering kit, and soldering helping hand. Measuring & Testing Tools: Digital multi meter, digital Vernier caliper, spirit level, measuring tape, and pen electric tester. Digital oscilloscope, adapters, telescope, DIY paper microscope Power Tools: Cordless rotary multi tool, dual-temperature heat gun, air blower, and hot glue gun.Organization & Workspace: Plastic trays, pegboard, and return measuring tools Intel Core i5 - 1245U Mid Level Laptop - Notebook Specification: Laptop Type: Mid LevelIntel Core i5 - 1245UOperating System (Factory Pre- Loaded)Window 11 HomeRAM Size (GB)16Display Size (in cm) – Diagonal: 35.56 to 38.09 (14 In to 14.99 In)Capacity of Storage Drive (in GB)512 65 Inch Display Interactive Panel with CPU Size (Diagonal): 65 or higher Panel Technology: IPS / VA Resolution: (Minimum) 4K (3840 x 2160) Viewing Angle (Hx V): 178*178RAM: 4 GB or higher On-board memory: 32 GB or higher Input (Minimum): 3 x HDMI, 4 x USB (Out of, which min 2xUSB3.0),1 xAudio, 1 x OPS slot, 1 x USB Type C Port Output: (Minimum) 1 x HDMI, 1 x Audio The software enables teachers to generate presentations using Al in PPT or PDF format. The teachers can select their Class, Subject, Topic and language to generate the presentations. The software supports all Indian and Global languages including English, Hindi, Marathi, Kannada, Tamil, Telugu, Gujarati, etc. Using Al, the software is able to analyse the Class and Subject and generate output accordingly. Using the Ask Me Anything tool, the teachers can search queries related to any topic and the Al is able to generate Class-wise and Subject-wise results including Images, Videos (YouTube Videos) and Explanation. Connected Classroom Software has in-built Generative Al capability to search and import filtered content relevant to Class and Subject. - images, videos, explanation for queries given by teachers in all languages. Teachers are able to import images and videos for teaching in class. The software has a text-to-speech function (for all languages) to convert text-based explanation into speech and read out loud in class. Software has Two-Way Live Conferencing Feature with education specific features Live conferencing feature also enables recording which gets directly uploaded to cloud.. Reports: Detailed reports for Attendance, Assessments, Study Material, are available for administrators to access. Administrators should be able to access to view the whiteboard saved by the teachers and monitor the usage.. Below tools and simulations are provided for enhancing the teaching-learning experience: - Graph: Demonstrating equations using 2D and 3D visualizations - Calculator: Standard and scientific - PHET simulation library with 100+ simulations across Maths, Physics, Chemistry, Biology. 2 kVA OFF LINE UPS Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete Battery 75/80 AH capacity Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 6Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 26 8 Module Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 27 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire with switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch 28 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Point wiring using Copper wire without switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 29 1.5 mm2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 30 Fans : 48 Sweep (1200 mm) Regular model Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 31 LED Down Light 15-18W Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per W, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 32 Fall Ceiling for Innovation lab to cover entire Area Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. 33 Floor Mat for Innovation lab to Cover the entire Lab Providing and laying linoleum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications 34 Repair and Replacement of Windows and Doors (if required) Repairing door and window frames with available wood to the required size. 35 Painting Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete.(P No.59, SI.No 9.1 PWD SR 2023-24 Volume 2) Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification.( SI.No 8.33.1 PWD SR 2023-24 Volume 2) Polyurethane based ingle Component for Existing surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification (P No.A-149, SI.No 15.2 PWD SR 2023-24 Volume 1) Model Table - Modular Table with MDF Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface not to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus 75 mm). Student Table - Modular Table with Particle Board Table Top and Metal Understructure Item Description:Providing and supplying PROGARCE Rectangular N.A Classroom tables Mode of supply assembled ready to use. Shape of the table Rectangular. Style of table supported by set of leges. Design of table with four legs and foot rest ring. Loading capacity of table top in KG (+-5 Kg) 150 Kg. Foot rest provided, Approval of advance sample (in respect of design) MATERIAL Table top material Ply wood. All side beeding on eddge of table top, 5 mm thick Teak wood Shoes material rubber. Padestal (under structure) Mild steel dquare section of outside side minimum 25 mm and wall thicknes sminimum 1.2 mm. Foot rest material Mild steel square section of size 25x25 mm and wall thickness minimum 1.6 mm. Leg material 25 mm MS pipe heavy duty. DIMENSION Table top length +- 10 (mm) 900 mm. Table top width +- 10 (mm) 600 mm. Table Height +- 10 (mm) 750 mm. Table top thickness 19 mm. MISCELLANEOUS Number of buffers four number at bottom. Wleding joint to be smooth fnished sharp edges to be removed - Free from objectionable projection or irregulatiries. Top to be ftted by welding. Number of Bolt 2 bolt in length side and 1 bolt in width side. Table placed on even surface not to wobble. Distance between legs length of table top (minus 75 mm) x width of table top (minus mm). Trainer Table - Executive Table with Pedestal, 3 Side Storage Unit Student Chair – Providing and supplying Unbranded wood chair/stool, already assembled Technical Specifcation Chair feature painting. Color-Other, Style Traditional. Furniture Assembly Already Assembled. Material Wood. Additional Parameters Additional Features good quality wooden arm chairs. Trainer Chair - Revolving Chair with Synchronic tilt mechanism Training of Teachers The Master Trainer will conduct a 2-day Training of Trainers (ToT) program educators on effectively utilizing the Innovation Lab . The training should cover hands-on learning methodologies, STEM education, and practical applications lab tools and technologies (P No.A-48, SI.No 1 PWD SR 2023-24 Volume 1) Technical Support
Contract Date: Ref. Documents Contract Value : 53.88 Lakh
Government Departments No of Bidders 1
46.
Housing Urban and Rular Development #8634661 AOC
Tender For Maintenance Of Various Schemes Under East Zone. Sh:Provision Of Street Light At Mayur Vihar Phase-Ii East Zone Delhi.; 1 1.0)Supply, erection, testing and commissioning of hot dip galvanized octagonal steel pole of 6 Mtr. height and made of 3 mm sheet thickness-3mm with a ring of 250 mm,having bottom 130mm OAF & top 70 mm OAF, hot dip galvanized M.S base plate of size 220 mm x 220 mm x 12 mm thick, single & double overhang bracket made of 3.60 mm thick hot dip galvanized M.S. pipe with 0.5 Mtr. longtube of suitable dia to accommodate the pole & fittings, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:- (a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existingmounting strips inside the flush door. (b) 4 nos. 63 Amp terminal block suitable forfollowing conductor / cable, fixedonDIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet.(i)10 sq. mm. conductor – 4 nos and short links 4-nos. (ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire.(c)6 AmpSP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earthingi/c washers, springs washers & nuts complete as required etc.(d)Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required. 2 Foundation nuts & bolts 3 2.0) Providing and laying in position, reinforced cement concrete (1:2:4 concrete mix) foundation of size 500 mm long x 500 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1460 mm long (approx.) - 8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 1860 mm long (approx.)-8 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-20 x 700 mm long (150mm top threaded portion & 250 mm top galvanized portion) M.S. foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with templates/Anchor plate of size 220 mm x 220 mm x 4 mm thick having 4 Nos. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63mm (OD) 2 Nos. DWC pipe for cable entry and exit as required. 4 Lighting Fixture 5 3.0)LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioningof Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 6 90 Watt 7 Wiring from pole control box to light fitting(s) 8 4.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor Single core cable in the existing surface/recessed steel/PVC conduit/ Pole as required.a) 3 x 1.5 Sq.mm 9 Cables & cable laying 10 5.0)Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. 11 5.1) 2 x 10 Sq.mm 12 6.0) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 13 6.1)63 mm dia (OD-63 mm & ID-51 mm nominal) 14 7.0)Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe / pole as required. 15 7.1)Aabove 35sq.mm and upto 95 sq.mm 16 8.0) Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 17 8.1) 80 mm dia 18 Feeder Pillars 19 9.0) Supplying, installation, testing and commissioning of floor mounted feeder panel duly compartmentalized (outdoor type) double door cubicle panel board of Suitable size made out of 2mm thick CRCA MS sheet having hinged gasketed cover and screw type knob with double locking arrangement and rain protection cover mounted on MS angle iron base frame made out of 40 mm X 40 mm X 5 mm angle iron with 1 mtr. Long leg grouted with 1:3:6 foundation and should be as per drawing approved by Engineer-In-Charge. Legs should be covered with brick wall, connection, interconnection with painting after applying a coat of primer,i/c connection inter connection of the accessories mounted there on with suitable size of copper wire with thimble/lugs, earthing the body of the feeder paneli/c supplying & fixing of the following items : INCOMERa) 63A 4 pole 25 kA MCCB - 1 Nob) Ammeter with selector switch (0-25 A)- 1 Noc) Voltmeter with selector switch (0-500 V) - 1 No d) Indication Lamp (RYB) with control HRC fuse with fuse fitting- 1 set.BUS BAR 50 A TPN Al. Bus Bar (suitable size) -1 SetOUTGOING a) 16 A TP&N 10 kA MCB - 4 Nos.b) Power contactor - 1 No.c) Astronomical Timer switch – 1 No.d) Auto/Manual toggle switch – 1 No.e)Compartment having space for DISCOM energy meter with 6mm thick Bakelite sheet for mounting energy meter.f) Danger Notice plate – 1 No.g) Lightning inside the feeder pillarNote: Foundation dully plastered and finished shall be made as per site requirement for which nothing extra shall be paid. 20 10.0)Supplying fabrication and installation of wire mesh protection cover guard for main feeder pillar made out of 8 SWG wire mesh of suitable size with MS angle iron base frame 40 mm X 40 mm X 5 mm and 0.5 Mtr. long leg spot and MS strip with support size 40 mm X 6 mm as per drawing approved by Engineer-in-Charge i/c providing door of suitable size with S/F of godown lock, locking arrangement, painting and grouting of angle iron frame in CC 1:2:4 etc. complete as required. 21 Cable end termination 22 11.0)Supplying and making end termination with brass compression gland and aluminium lugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 23 11.1) 2 X 10 sq. mm (19mm) 24 Earthing 25 12.0)Earthing with G.I. Earth Pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 26 13.0) Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for conneciton etc. as required. 27 14.0) Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut bolt , spring washer, excavation, refilling etc. as required. 28 15.0) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existingsurface /recessedconduit submain wiring /cable as required. 29 16.0)Supply, boring and laying of HDPE DWCpipes (ISI) marked of the 90 mm dia size confirming to IS:4984 with pressure rating of 6KG/Sq.cm by trench less technology with no dig. Method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning, rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe. etc. complete as required. 30 17.0)Painting of existing 9/12 Mtr high GI street light poles including cross arms, brackets, junction/control box etc. with one coat of primer and two coats of synthetic enamel paint of approved shade (generally aluminum/silver color), including cleaning the surface of all dirt, grease, rust etc., and writing pole number with black enamel paint on yellow background, complete as per direction of Engineer-in-Charge atKondli Gharoli.
Contract Date: Dec 10, 2025 Contract Value : 15.05 Lakh
Local Bodies No of Bidders 6
47.
Water Resources and Irrigation #8632850 AOC
Tender For WORK SCHEDULE FOR EXECUTION OF CIVIL WORK & INSTALLATION WORKS OFAT KHARIDICHAK-III RL L.I. PROJECT IN BHOGRAI BLOCK IN BALASORE DISTRICT UNDER REINFORCEMENTGRANT-2024-25-- 1 Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. 2 Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. 3 Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. 4 Cement concrete (1:2:4)using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. 5 Brick work with Fly ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. 6 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. 7 Cement Punning over the plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. 8 R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. 9 Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. 10 Colour washing three coat with stone lime and colouring materials per 1 Sqm 11 Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. 12 Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 10HP/7.5KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class Finsulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery = 100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares. 13 Labour charges for installation of 10HP Monoblock Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting ,threading, welding and construction of supporting pillar including transportation etc. complete as per the direction of the Engineer-incharge. 14 100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark. 15 100 mm dia G.I. bend IS No.1239(Part-II/1992) 16 100 mm dia G.I. flange IS No.6392 / 1971 17 100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand 18 100mm dia GI Socket IS 1239 (Part-II/1992 ) 19 100x100x25mm G.I. Tee with Plug for priming 20 5/8 x3 Nut bolt & Foundation Nut boltas per IS specification 21 1/8 thick Rubber Insertion as per IS specification 22 cost of 200mm×110mm dia PVC reducing socket. 23 Base frame for panel (size 0.40mx0.20m) made with 3 size M.S. channel having suitable holes for fitting of panel Board, coloured with one coat of red oxide primer and two coats of smokes grey enamel paint & Base frame for motor (size 0.50mx0.27m) made with 3 size M.S. channel having suitable holes for fittings of different size and make 3 phase centrifugal monoblock pump set from 10 H.P. to 15 H.P. coloured with one coat of red oxide primer & two coats of smoke grey enamel paint. 24 Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray / navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board. 25 Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp 26 63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark. 27 3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming. 28 Cost of Empty outdoor irrigation panel board (size 0.45mx0.25mx1.20m) of 18 SWG (cold rolled) M.S. sheet with one coat of red oxid primer and two coats of smoke gray / navey blue enemel paint on both side ( inside & outside) suitable to mount 3 phase starter, Main Switch and capacitor inside the pannel board vertically over 18 SWG M.S. sheet. The pannel board should be provided with locking arrangement and have grover on rear side for fixing motor hood. The danger board should be fixed on the to of the pannel door. 29 Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 400 kg 10 M long PSC Pole with 80 Sqmm AAAC ,11 KV V Cross arm, with required No.of 11 KV T & C Disc. Insulators in tension point &11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. including cost of all materials, labour transportation,inspection & commissioning etc. complete. 30 Construction anderection of 11 /0.4 KV ,25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 400 kg 10 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for25 KVA S/S, G.I.pipe earthingwith 25X5mm G.I.Flatsincluding cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, barbed fencing ( size (15x10) with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning. 31 Consturction of Barbed wall of Substation 32 Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduite pipe, No.6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. 33 Electrical Earthingwith digging earth pit of size (2 ft X 2 ft X 3 ft ) and using 1/2 G.I pipe ,No -6 G.I wire ,cable socket ,Flange , carcoal, salt etc. as per the direction of the Engineer-incharge. 34 3 X 2.5 mm2 s/s Flat cable
Contract Date: Jan 21, 2026 Contract Value : 6.25 Lakh
Government Departments No of Bidders 2
48.
Defence #8584575 AOC
Tender For Provision Of Roof Top Solar System At Nsry, Naval Base Karwar; 1 Design, Supply, installation, testing and commissioning of grid connected roof top solar generation system of capacity 500 KWp AC capacity with connected accessories all as specified and directed as per PS clause incuding specification as follows:- 2 (A) Supply, Installation, testing and commissioning of 500 KWp SPV system comprising of 540/545/535 Wp solar photo voltic modules/array of high efficiency made of mono crystalline silicon solar PV cells with supply and fix of terminal box on the module havingprovision for opening & replacing the cable etc.The general features of PV modules shall be as given below :- a) The module shall be made up mono crystalline silicon cells. b) The interconnected cells shall be laminatedin vacuum to withstand adverse environmental conditions. 3 c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm. e) Surge arresting devices to be provided at junction box and module shall be provided with bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be atleast five years warranted by manufacturer. Note :- (i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 0.25% spare qty of modules of total installed modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost. 4 (iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:-(a) Name of the manufacturer of PV Module(b) Name of the Manufacturer of Solar cells(c) Month and year of the manufacture for solar cells and the module(d) Country of origin (make in INDIA only)(e) I-Vcurve for the module(f) Wattage, Im, Vm and FF for the module(g) Unique Serial No and Model No of the module(h) Date and year of obtaining IEC PV module qualification certificate(j) Name of the test lab issuing EC certificate(k) Other relevant information on traceability of solar cells & module. 5 (B) Module Mounting Structure (MMS) 6 Supply & fixing of the anti-corrosive factory made Aluminium Rail fixed over HDGI (Hot dip galvanised Iron) structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, stainless steel nuts & bolt. The minimum thickness of Aluminium & mounting stainless steel structure shall be as per IS 4759 & IS 2061-1992 respectively withstand the minimum wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. 7 Note:- (i) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submittedby the contractor. (ii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iii)The fasteners should be of HDGI and should allow easy replacement of any module.(iv) The minimum clearance of the structure from the roof level should be 300 mm.(v) The tenderer shall not make any damages to roof/water proofing treatment while fixing solar module or mounting structure, if any damege occured shall be rectified to the satisfaction of GE without any extra cost to the Govt. 8 (C) Solar DC Cables:- 9 (i) Supply & laying of cable from solar module to inverter, 1 C X 4 Sq. mm Solar cable XLPO- Flexible tinned copper stranded class -5 conductors as per IEC-60228, Insulation– Cross linked Polyolefin, Outer sheath – Halogen free Polyolefin Black Colour as per site requirment as ISI marked in through PVC rigid conduit pipe by saddling as per direction of IEC. (For Solar Array DC supply connection). 10 (D) DC Combine box 11 A DC combine box inbuilt in the inverter shall be used to combine the DC cables of the solar module array with DC fuse protection for the outgoing DC cables to the DC distribution box. 12 (E) Array junction boxes 13 The number of junction boxes as per design given by OEM are to be provided in the PV array for termination of connecting cables. All wire/cables must be terminated through cable lugs. Copper busbar/terminated blocks housed in the junction box conforming to IP 65 degree of protection with EPDM rubber gasket to prevent water entry. Junction boxes shall be mounted on the MMS such that they are easily accessible and protected from direct sunlight & harsh weather. 14 (F) On Grid Power Conditioning unit ( Inverter) 15 Supply & installation of 415V 3-ph, 50 Hz, microprocessor DSP type grid connected Inverters which converts DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power source on site. Provisioning of power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 10% & frequency vatiation +/-3 Hz) Note :-(i) No of inverters shall be provisioned as per design given by OEM. (ii) Inverter should have internal protection arrangements against any sustainable fault in feeder line and against the lightning on feeder.(iii) Should have isolating transformer(iv) Inverter efficiency >97% (without inbuilt galvanic isolation) and >93% (with inbuilt galvanic isolation). (v) No load losses shall be less than 1% of rated power.(vi) The above quoted rate is inclusive of MS structure stand duly fixed on roof for placing inverter. 16 (G) Solar meter & Net meter 17 (i) Solar Generation Meter -01No (ii) 3 Phase Bi-Direction Meter-01 No at the main HT 110/11 KV takeover pointas per DISCOM requirement to be provided. (iii) The SPV plant to be connected with Grid supply where Captive both DG set also been placed. Therefore a provision of the reverse power relay shall be provided in the DG set incomer panel to both DG Set circuit. 18 (H) AC Distribution Board 19 (i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from PCU/ Inverter & provided by necessary surge arrestors system and solar energy meter (KWH) with IP65 protection and suitable capacity of MCCBs (One number incoming and One number outgoing). Note: ACDB shall be covered as per OEM design in such a way that structure must sustain 180 km/hr wind speed. The cost of provn for same is inclusive in quoted rate. 20 (J) AC Cables 21 (i)CABLE FROM INVERTER TO ACDB -4 C x 60 Sq. mm, Al Conductor, XLPE Insulated, Unarmouredas per site requirment fixed on wall with saddle (For AC power supply from Inverter to AC distribution board Panel). 22 (K) Protection 23 (i) The system shall be provided with all necessary protection like earthing, lightening & surge protection as per relevant standard. (ii) Protection relay for reverse supplyto 2.5 MW DG Set to be provided - 02 Nos 24 (L) Performance testing 25 Ratio between the theoretical energy outputs of the SPV plant is termed as performance ratio and is measured in accordance with IEC 61724. Based on prevailing climatic and temperature conditions in India, a performance ratio of 75% is expected for crystalline modules. 26 (M) Other Misc items 27 (i) Web Monitoring portal software -01 No. (ii) The report of genereted unit of solar power on monthly basis is to be submitted to the department. 28 (N) Earthing System 29 (i) Earthing system for Structure, DCDB, INVERTER, ACDB- 1C X 16sqmm, Copper Cable and1C X 35sqmm, Copper Cable as per site requirment and as per MNRE specifications to be provided. (ii) Earthing Pit- Earthing Chemical Kit - 2Mtr GI Rod + 20 Kg bag - 02 Nos. 30 (O) Lightening protection 31 Conventional Type lightning arrester- 25 Mtrs - 02 Nos, including 1C X 70 sqmm, Copper Conductor Unarmoured and 25X5 mm GI earth strip - LA earthing as per site requirment and as per MNRE specifications to be provided. 32 (P) Installation, Testing & Commissioning 33 As per safety norms of SERC/CEA to be provided. Satisfactorily testing and commissioning of the system is to be done by the contractor in presence of the rep of accepting officer and the report of the complete system is submitted to department. 34 (Q) O&M and Warranty 35 5 years from the date of commissioning to be provided. Warranty for 05 years means the entire system of roof top solar plant should work in healthy condition during this period. All the parts, which warrant repair/replacement in the opinion of the GE or as per site requirement shall be repaired or replaced accordingly. The: parts which will be replaced curing currency of warranty period shall be of the make/specifications provided originally by OEM. It is specifically brought out that the quoted rates deemed to be included repair/replacemer of each and every part of the Plant installed uncer the Schedule A during warranty period. 36 (R) Walkway/Water Piping/Hand Rail as per the site. 37 Note: The quoted rate deemed inclusive of the following:- 38 (i) Transportation charges with Transportation Insurance for the all material of on grid solar roof top system including loading & unloading at site from workshop. 39 (ii) Insurance for the complete system for the 5 Years. 40 (iii) Necessary Approval/NOC to be obtained from KPTCL. 41 (iv) Installation of Net metering and liasionwith KPTCL for pre commissioning testing to be done. 42 (v) As per performance obligation, the contractor shall maintain minimum capacity utilization factor (CUF) of 19%. The report shall be submitted by the contractor to accepting officer as per guidelines promulgated by SECI. (vi) Arrangement for installation of solar roof top system on roof of all blags (MEWR P-03, FAB P-04, DSS-06, SIMA AC Plant shall be made by contractor without any extra cost. 43 (a)The contractor shall be fully responsible for the upkeep, maintenance, and performance of the entire solar installation for a period of 05 (five) years from the certified date of completion of work. A sum equal to 1% (one percent) of the contract amount shall be retained from the Running Account (RAR)/Final Bill towards performance guarantee of the solar system. This amount shall be released only after the satisfactory completion of the five-year warrantee period. In lieu of the above retention, the Garrison Engineer (GE) may accept a Bank Guarantee Bond (BGB) from any Scheduled Bank or a Fixed Deposit Receipt (FDR) pledged in favour of the GE from any Nationalised Bank, valid for 05 years, covering the equivalent amount. In such a case, no deduction will be made from the RAR/Final Bill on this account. 44 (b) The contractor shall also submit a warrantee from the OEM/manufacturer or authorized system integrator on a non-judicial stamp paper, covering the solar panels, inverters, mounting structures, and associated components for a period of 05 (five) years from the certified date of completion. The warantee shall state that the system will remain free from defects, performance failure, corrosion, or degradation during this period. Submission of this OEM/system integrator warantee shall be mandatory prior to release of final payment. This shall, however, not relieve the contractor of his contractual responsibilities. The contractor shall remain liable to repair, replace, or rectify any failure or defect noticed during the five-year period at no additional cost to the Government 45 M&L for Cleaning of Grid connected type solar power plant of capacity 500 KWp and Panels made with mono crystalline PV Module and mounted on AL Structure complete installed against item no -01 herein before on roof top of Bldgs (MEWR BLDG P-03, FAB Bldg P-04, DSS 06, SIMA AC Plant) (comprising of all devices and accessories through out 12 months (twice in a month) for a period of 05 years after completion of work complete all as specified and directed. 46 M&L for Electrical Non comphrehensive maintenance of Grid connected type solar power plant of capacity of 500 KWp and Panels made with mono crystalline PV Modules and mounted on Aluminium Structure complete installed against item no -1 herein before on rooftop of Bldgs NRY ((MEWR BLDG P-03, FAB Bldg P-04, DSS 06, SIMA AC Plant)) comprising of all devices and accessories through out 12 months (Once in a month) for a period of 05 years after completion of work complete all as specified and directed.Note:- Any defective spare parts shall be replaced by the contractor without any additional cost during the waranty period of 5 years. 47 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core. 48 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting outin soft/loose soil all as specified and as directed. 49 Returning,filling in including spreading,levelling, watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and as directed. 50 Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed. 51 Supply and laying of flexible DWC pipe of nominal diameter 100 mm under the ground and drawing the XLPE cable through the DWC pipe complete all as specified and as directed. 52 Supply, installation, testing and commissioning ofLT panel Outdoor type made out of 3.15mm thick CRCA sheet and mounted on PCC foundation weather/dust proof, factory made, IP-54 with Doble door openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 440V, 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCBs with suitable size of Aluminium bus bar or with stranded copper cable and fixing on suitable U shaped PCC platform comprising of the following accessories complete allas specified and directed by Engr in charge :Note: (a)The LT panel should be procured through CPRI approved manufacturer(b) The proper gland pacing for the cable entries to be provided.(c) The design of the LT panel to be taken prior approval from GE before procurement 53 (i) Aluminium bus bar with proper colour code -04 Nos. 1000 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations.(ii) Indicator Lamp-01 Set (Set of three)(iii) Incomer MCCB, 415 Volt, 4 pole, 800 Amps, 50 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 02 No 54 Outgoing :- (i )MCCB, 415 Volt, 4 pole, 800 Amps, 50 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100%- 01 No.(ii) Digital Voltmeter 0-500 Voltand Digital Ampmeter0-800 Amp with selector switches (iii) Complete wiring with suitable size copper cable, thimble etc. (iv) All outgoing MCCB Shall be connected through spreader and copper busbar not less than 10 mm thick strip. (iv) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 450 mm height above ground level . 55 M&L for Earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Copper Strip of size 20x3mm size, by means of bolts, nuts, check buts and washers as earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable lengthplaced on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth platewith fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. 56 Testing & Commissioing of Bi- Directional meter on 110/11 KV Main HTtaken points at Arga 110/11 KV Substation of Naval Base Karwar including taking permission from KPTCL/HESCOM for feasibility of 500 kwp roof to solar system complete all as specified and as directed.
Contract Date: Jan 12, 2026 Contract Value : 3.94 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
49.
Defence #8519250 AOC
Rate Contract For Supply Of Kirloskar Make Generator Spare Parts , Rate Contract Of Generator Spare Parts For Kirloskar Make (Any Where In Hq 15 Corps Zone) , Special Washer - M14 Bolt Cart Part No 02.001.04.0.00 , Disc Plug Cart Part No 02.001.13.0.00 , Split Bush Cart Part No 02.001.14.0.00 , Coupling Disc Kg 42.3, Sae 11.5 Cart Part No 02.001.16.0.00 , Spring Washer(M8) Cart Part No 02.002.05.0.00 , Oil Spray Nozzle Assly Cart Part No 02.002.10.0.00 , Hard Washer 13 X21 X1.5 Cart Part No 02.005.04.0.00 , Scraper Ring Cart Part No 02.014.09.0.Pr , Inline Fip: Ha294 G1 20.5 Hp at 1500 Rpm Cpcb-Ii Cart Part No 02.015.04.0.00 , Shim Ring: Cyl Liner 0.2Thk Cart Part No 02.019.03.0.00 , Cylinder Liner Cart Part No 02.019.04.0.00 , Liner For Scraper Ring Cart Part No 02.019.08.0.Pr , Piston Pin Cart Part No 02.020.02.0.00 , Piston Ring Set Cart Part No 02.020.40.0.00 , Piston Assembly Cart Part No 02.020.50.0.00 , Piston Ring Set Alcan3r Cart Part No 02.020.60.0.00 , Small End Bush (S/F) Cart Part No 02.021.03.9.00 , Connecting Rod Bolt Cart Part No 02.021.04.0.00 , 3R1040tc Small End Bush Cart Part No 02.021.11.9.Pr , Cylinder Head Bolt 12X211 Cart Part No 02.022.03.0.00 , Washer Cart Part No 02.022.04.0.00 , Washer Cart Part No 02.022.06.0.00 , Button For Injector Yoke Cart Part No 02.022.07.0.00 , Locking Screw Cart Part No 02.022.09.0.00 , Valve Cup Cart Part No 02.022.11.0.00 , Valve Collet Cart Part No 02.022.12.0.00 , Valve Spring Cart Part No 02.022.13.0.00 , Valve Seat Insert -Inlet Cart Part No 02.022.15.0.00 , Valve Seat Insert -Exhaust Cart Part No 02.022.16.0.00 , Valve Guide Cart Part No 02.022.17.0.00 , Wire Snap Ring Cart Part No 02.022.18.0.00 , Spring Cup Cart Part No 02.022.21.0.00 , Nut M8 (Brass) Cart Part No 02.022.24.0.00 , Copper Washer Cart Part No 02.022.25.0.00 , Valve Collet-3-Groove Cart Part No 02.022.28.0.00 , Valve Seat Insert (Exhaust) Cart Part No 02.022.31.0.00 , Valve Seat Insert: Exhaust Cart Part No 02.022.31.7.00 , Cylinder Head Reconditioning Kit Ha Engine ( Bs Ii) Cart Part No 02.022.50.0.00 , Cylinder Head Reconditioning Kit Ha Engines (Indl Bsiii & Pg Cpcb) New Model (Post) Cart Part No 02.022.60.0.00 , Valve Tappet Cart Part No 02.024.01.0.00 , Sealing Ring Bottom Cart Part No 02.024.02.0.00 , Sealing Ring Cap Cart Part No 02.024.03.0.00 , Spring Cart Part No 02.024.04.0.00 , O Ring: Top P.R. Tube 5.3X17 21507 Cart Part No 02.024.05.0.00 , Washer Cart Part No 02.024.09.0.00 , Rocker Arm: Adj Screw Cart Part No 02.024.13.0.00 , Oil Metering Screw Cart Part No 02.024.14.0.00 , V.R.Toe Cart Part No 02.024.15.0.00 , Valve Rocker Assly Cart Part No 02.024.20.0.00 , Gasket For Rocker Cover Cart Part No 02.024.21.0.00 , Bush For Support Cart Part No 02.024.25.0.00 , Nut: Rocker Adj Screw Cart Part No 02.024.27.0.00 , Rocker Cover Cart Part No 02.024.32.0.00 , Push Rod Tube Cover: Ha Cart Part No 02.024.33.0.00 , Washer(Rocker Lever) Cart Part No 02.024.38.0.00 , Rocker Cover Gasket Cart Part No 02.024.41.0.00 , Push Rod: Welded Cart Part No 02.024.48.0.00 , Rocker Lever Assembly Cart Part No 02.024.50.0.00 , Push Rod: Welded Cart Part No 02.024.70.0.00 , Rocker Cover Gasket Cart Part No 02.024.97.0.00 , Nozzle Washer (Thickness - 3Mm) Cart Part No 02.025.01.0.00 , Expansion Module For Kg645 Cart Part No 02.026.10.0.Pr , Kg640i Controller Unit With Renesas Hardware Cart Part No 02.026.100.0.Pr , Genset Control Unit Gc2111 Cart Part No 02.026.11.0.Pr , Kg934 Front Facia Cart Part No 02.026.13.0.00 , Gc2112 Controller Unit Cart Part No 02.026.14.0.Pr , Kg645 C Controller Unitsp 3 Hardware 12V Cart Part No 02.026.26.0.Pr , Kg645 B Genset Control Unit Cart Part No 02.026.27.0.Pr , Kg640 Controller Unit (Sp-3 Hardware 12V) Cart Part No 02.026.31.0.Pr , Kg645 Controllerunit With 4-20Ma Cart Part No 02.026.32.0.Pr , Kg645e Controller Unit (Sp-3 Hardware 12V) Cart Part No 02.026.34.0.Pr , Kg640c Controller Unit For Cpcb4 Engine Cart Part No 02.026.36.0.Pr , Kg645c Dedicated For Png Dv8 Engine Configuration Cart Part No 02.026.37.0.Pr , Genset Control Unit Gc2111 Cart Part No 02.026.61.0.Pr , Ball Bearing (20X47x14) Cart Part No 02.027.05.0.00 , Rubber Grommet Cart Part No 02.029.04.0.00 , Injector With Conical Sac S Type Nozzle Cart Part No 02.030.03.0.00 , Injector Cart Part No 02.030.08.0.00 , Bush For Injector Cart Part No 02.035.08.0.00 , Rubber Sleeve Cart Part No 02.036.03.0.00 , Dipstick Guide Cart Part No 02.037.04.0.00 , Dual Banjo Bolt-M8 Cart Part No 02.037.06.0.00 , Joint : Exh Inlet Cart Part No 02.045.08.0.00 , Set Of Joints Cart Part No 02.050.10.0.Sp , Set Of O Rings: Ha294 Cart Part No 02.051.10.0.00 , Cylindrical Dowel Between Cr Case And F W Hsg Cart Part No 02.052.04.0.00 , Counter Weight Cart Part No 02.053.02.0.00 , Crankshaft Assly With Gear Cart Part No 02.053.10.0.00 , Lube Oil Pump Assly With Drvg Gear Cart Part No 02.056.50.0.00 , Air Inlet Mfold: Ha2 Finish Cart Part No 02.058.01.0.00 , Joint: Air Inlet Manifold Cart Part No 02.058.07.0.00 , Exhaust Mfold: Ha2 Cart Part No 02.059.01.0.00 , Set Of Joints Cart Part No 02.060.20.0.00 , Lower Cowling Cart Part No 02.061.01.0.00 , Top Air Baffle Cart Part No 02.062.01.0.00 , Rear Cowling Cart Part No 02.063.01.0.00 , Exhaust Air Baffle Cart Part No 02.064.10.0.00 , Cooling Air Blower Asslytwo Belt Cart Part No 02.067.20.0.00 , Upper Cowling Assly Cart Part No 02.068.10.0.00 , Breather Tube Cart Part No 02.069.01.0.00 , Stopper For Breather Tube Cart Part No 02.069.03.0.00 , V Belt: A46 Cart Part No 02.071.01.0.00 , Lub Oil Pipe Cart Part No 02.074.02.0.00 , Delivery Tube Cart Part No 02.081.01.0.00 , Sealing Ring - Lube Oil Cooler Cart Part No 02.083.02.0.00 , Lube Oil Cooler- Aluminium Cart Part No 02.083.04.0.00 , Rs485 High Voltage300v Ac Or 250 Dcprotection Kit Cart Part No 02.083.56.0.00 , Ecu For Gas Engine Cart Part No 02.086.01.0.Pr , Sub Assly Leak Off Pipe Cart Part No 02.088.20.0.00 , Exhaust Mfold Cum Silencer With Clip Cart Part No 02.091.01.0.00 , Fuel Pipe: 7.5 14X14b- 700 Wb Cart Part No 02.102.02.0.00 , Fuel Pipe Return Fip To Tank Cart Part No 02.102.13.0.00 , Front Cover Cart Part No 02.1031.01.0.00 , Headertopfor Spin On Filter Finish Cart Part No 02.1033.06.0.00 , Joint: Crankcase & Header Cart Part No 02.1033.09.0.00 , Header Assembly Cart Part No 02.1033.20.0.00 , Bracket: Alternator Cart Part No 02.1035.01.0.00 , Sae 1 Flywheel Housing Suitable For Dowel Mtg. Cart Part No 02.104.02.0.00 , Exhaust Manifold Cart Part No 02.1046.01.0.00 , Crank Pulley Cart Part No 02.1047.01.0.00 , Plate For Fuel Filter Mtg Cart Part No 02.112.01.0.00 , Flywheel Assly Cart Part No 02.116.10.0.00 , Wet Pm Kit (W/O Oil) For 02.1168 Cart Part No 02.116.8.0.Sp , Lever For Engine Stopping Cart Part No 02.118.01.0.00 , Sleeve: Nozzle Cart Part No 02.120.04.0.00 , Cylinder Head Assly Cart Part No 02.120.30.0.00 , Belt Guard : Frp Cart Part No 02.121.01.0.00 , Wiring Harness Tie 200Mm Lengthin Black Colour Cart Part No 02.1216.01.0.00 , Bearing Housing Cart Part No 02.124.01.0.00 , Crankcase Assembly Cart Part No 02.1263.10.0.00 , Crankcase Assembly Cart Part No 02.1263.20.0.00 , Belt (Avx 10 1500) Cart Part No 02.1266.01.0.00 , Belt: Avx 10 1545 Spz Cart Part No 02.1266.03.0.00 , Alternator Mtg Bracket Cart Part No 02.1268.01.0.00 , Piston Assembly Cart Part No 02.182.10.0.00 , Piston Ring Set (Tc) Cart Part No 02.182.30.0.00 , Cylinder Liner Cart Part No 02.183.01.0.00 , Joint For Cover Plate Cart Part No 02.187.24.0.Pr , Gasket For Iot Sensor For 20Kva R-Jio Cart Part No 02.187.28.0.Pr , Fuel Spout For R Jio Cart Part No 02.187.29.0.Pr , Wet Pm Kit (W/O Oil) For 02.2136... Cart Part No 02.213.6.0.Sp , Adaptor Pepper Pot Silencer Cart Part No 02.238.01.0.00 , Power Panel Assembly For Apu 3 5 Kw Cart Part No 02.240.40.0.Pr , 7 5Kw Apu Fuel Level Sensor Cart Part No 02.243.49.0.Pr , Set High Press Pipe Ha294 Cart Part No 02.298.90.0.00 , Air Inlet Manifold Sf Start Pilot Cart Part No 02.301.01.0.00 , Adaptor: Long Extension Shaft Belt Cart Part No 02.302.01.0.00 , Spinon Lube Filter Ctg Ha294 Cart Part No 02.320.02.0.00 , Exhaust Silencer Cart Part No 02.322.01.0.00 , Rain Cap Cart Part No 02.322.03.0.00 , Fuel Pipe: Nozzle Overflow To Fuel Tank Cart Part No 02.342.05.0.00 , Rubber Pad For Fuel Tank Mounting Cart Part No 02.347.03.0.00 , Special Stud For Fuel Tank Cart Part No 02.347.04.0.00 , Wiring Harness: Ha294 With Alt Cart Part No 02.365.20.0.00 , Dipstick Assly Cart Part No 02.401.10.0.00 , Fuel Pipe Return With Union Nut Cart Part No 02.408.05.0.00 , Fuel Pipe Inlet M14x15 Banjo One Side M16x15 Union Cart Part No 02.408.06.0.00 , Starter 12V Cart Part No 02.410.03.0.Pr , Fuel Level Gauge Mech:Dial 95 Mm Cart Part No 02.411.02.0.00 , Valve Pair: Ha Crome Plated Cart Part No 02.422.40.0.00 , Engine Safety Unit 12/24V 6 Led Cart Part No 02.424.02.0.00 , Esu 6Lpd Type: V Belt & Hooter O/P 12Vdc Cart Part No 02.424.05.0.00 , Washer (Id 13 X Od 30 X 5Th) For Alternator Cart Part No 02.430.03.0.00 , Hard Washer ( 11 I.D. X 19 O.D. X 1.5 Th ) Cart Part No 02.438.23.0.00 , Piston Assembly Cart Part No 02.443.35.0.00 , Piston Assembly Complete Cart Part No 02.443.50.0.00 , Valve Seat Insert-Inlet Cart Part No 02.445.04.0.00 , Valve Seat Insert -Exhaust Cart Part No 02.445.05.0.00 , Valve Pair Inlet & Exhaust Cart Part No 02.445.10.0.00 , Injector Cart Part No 02.447.08.0.00 , Cam Shaft & Gear Assembly Cart Part No 02.448.10.0.00 , Genset Power Panel Assemblysf Kg 541,For 3Ph Cart Part No 02.467.70.0.Pr , Control Panel Schematic For 15Kva3ph With Kg640 Ip A Cart Part No 02.468.80.0.Pr , Control Panel Schematic For 15Kva1ph With Kg640 Ip A Cart Part No 02.468.90.0.Pr , Control Panelschematicfor 15Kva 3Ph Ha2 With Kg640ip B Cart Part No 02.469.80.0.Pr , Control Panel Schematic For 15Kva Ha2 1Ph With Kg640ip B Cart Part No 02.469.90.0.Pr , Relay Card With 3 Relayfor Start Stop Cart Part No 02.472.25.0.00 , Stop Solenoid With 12V 10A 75Mm Cart Part No 02.477.01.0.00 , Sub Assembly Of Engine Stopping Lever Cart Part No 02.478.20.0.00 , Adaptor: Lube Oil Supply To Fp& Pr Gauge Sendor Cart Part No 02.480.04.0.00 , Fuel Pump: Ha294 Lla-Llr Cart Part No 02.480.10.0.00 , Injector Cart Part No 02.481.01.0.00 , Fuel Return Pipem12x1 5 Adaptor And M14x1 5 Union Nut Cart Part No 02.486.42.0.Pr , Anti Vibration Mounts Cart Part No 02.492.01.0.00 , Button For Inector Yoke Cart Part No 02.494.01.0.00 , Hose Clamp -Const Press Spr Band Cart Part No 02.500.08.0.00 , Nozzle Leak Off Pipe Cart Part No 02.500.30.0.00 , Digital Line Voltage Monitormodel Vmrd Msp Cart Part No 02.508.38.0.Pr , Deflector Plate ( Ha - Light Weight Ccase ) Cart Part No 02.519.06.0.00 , Joint: Front Cover Cart Part No 02.520.02.0.00 , Flywheel Assembly Cart Part No 02.523.10.0.00 , Flywheel: Sub Assly Cart Part No 02.523.20.0.00 , Fuel Hose 5.1 D X11.5 X12.7 O Cart Part No 02.525.06.0.00 , Combined Leak Off Pipe Nozzle To Fip Cart Part No 02.525.10.0.00 , Fuel Hosehp Leakoff Pipe To Tank Pipe Cart Part No 02.525.12.0.00 , Comb Leakoff Pipe Nozzle To Fip Cart Part No 02.525.20.0.00 , Combined Leak Off Pipe: Ha2 Cart Part No 02.525.50.0.00 , Fuel Filling Hose S Type Cart Part No 02.526.07.0.00 , Flywheel Housing Cart Part No 02.528.03.0.00 , Engine Mounting Foot G.E.( F.P. Side ) Cart Part No 02.532.01.0.00 , Engine Mounting Foot Ge (Fp Side) Cart Part No 02.532.02.0.00 , Engine Mounting Foot For Fwestarter Side Cart Part No 02.532.03.0.00 , Engine Mounting Foot For Fwefuel Pump Side Cart Part No 02.532.04.0.00 , Cam Shaft Assembly ( With 18 Mm Cam Gear ) Cart Part No 02.534.10.0.00 , Fuel Pump Gear Cart Part No 02.535.01.0.00 , Intermediate Gear Support Cart Part No 02.536.03.0.00 , Intermediate Gear Assembly Cart Part No 02.536.10.0.00 , Crankshaft Gear (18Mm Width) Cart Part No 02.537.01.0.00 , Crankshaft Assly With Gear Cart Part No 02.537.10.0.00 , Expansion Bellow Cart Part No 02.538.04.0.00 , Pipe For Expansion Bellow To Silencer Inlet( For Ha2 ) Cart Part No 02.538.06.0.00 , Residential Silencer Cart Part No 02.538.10.0.00 , Rain Cap Cart Part No 02.538.12.0.00 , Tail Pipe For Ha2 Cart Part No 02.538.29.0.00 , Silencer Cart Part No 02.538.50.0.00 , Silencer: Ha2 9 Dia Body Cart Part No 02.538.70.0.00 , Silencer Assembly Cart Part No 02.538.81.0.Pr , Lube Oil Sump Cart Part No 02.539.30.0.00 , Air Cleaner Element Cart Part No 02.541.02.0.00 , Belt (Ax60) Cart Part No 02.542.02.0.00 , Air Cleaner Element Cart Part No 02.542.05.0.00 , Bracket: Air Filter Cart Part No 02.542.06.0.00 , Air Cleaner Assly: Dry Type Cart Part No 02.542.10.0.00 , Air Inlet Hose Cart Part No 02.542.13.0.00 , Air Inlet Hose Cart Part No 02.542.18.0.00 , Hose For Air Cleaner Cart Part No 02.542.21.0.Pr , Dry Type Air Cleaner Assly For Ha2 Cart Part No 02.542.30.0.00 , Fuel Filling Hose Cart Part No 02.544.04.0.00 , Drain Pipe: Lube Oil Sump- Ha294 Cart Part No 02.544.05.0.00 , Expansion Bellow 2.5: 2Ply Cart Part No 02.545.06.0.00 , Hex Weld Nutm8x1 25 Cart Part No 02.554.02.0.00 , Hex Weld Nutm6x1 00 Cart Part No 02.554.05.0.00 , Hex Weld Nut -M4x0.7 Cart Part No 02.554.22.0.00 , Suction Tube Assly Cart Part No 02.556.10.0.00 , Wiring Harness Assly Cart Part No 02.567.10.0.00 , Engine Wiring Harness Cart Part No 02.570.10.0.00 , Front Cowling Cart Part No 02.571.05.0.00 , Rear Cowling Cart Part No 02.571.06.0.00 , Hot Air Ducting Cart Part No 02.571.20.0.00 , Hot Air Ducting: Com Side Open Cart Part No 02.571.30.0.00 , Hot Air Ducting Cart Part No 02.571.50.0.00 , Combined Leak Off Pipe Nozzle To Pump (M12 Banjo) Cart Part No 02.583.10.0.00 , Double Row Angular Contact Ball Bearing Cart Part No 02.585.03.0.00 , Fan: 1211 Blades S/F Cart Part No 02.589.01.0.00 , Adaptor On Crank Pulley For Fan Mountingc I Cart Part No 02.589.04.0.00 , Flywheel Hsgmachiningsae 1S F Cost Reduction Cart Part No 02.594.01.0.Sp , Flywheel Assly Cart Part No 02.595.10.0.00 , Piston Assembly Completeha294 Cpcb Ii Cart Part No 02.618.100.0.Pr , Piston Assembly Cart Part No 02.618.30.0.00 , Piston Assembly Cart Part No 02.618.80.0.00 , Set Of High Pressure Pipe: Ha294 Cart Part No 02.619.90.0.00 , Silencer Strip Clamp ( Hr Black Paint Cart Part No 02.627.05.0.00 , Belt: Spz Avx10 X 1564 Cart Part No 02.637.01.0.00 , 18 Blowing Fan 230V 1Ph 50Hz Ip 55 Cart Part No 02.638.05.0.00 , Exhaust Fan With Front Grill, 18,415V, 3 Phase, 1400 Rpm, 50Hz Cart Part No 02.638.69.0.Pr , Anti Vibration Mounts Cart Part No 02.650.01.0.00 , Anti Vibrn Mtg -Alternator Cart Part No 02.650.02.0.00 , Anti Vibration Mounts Cart Part No 02.650.03.0.00 , Kit Group Assembly For Conversion Of Horizontal Stop Solenoid To Vertical Pum Cart Part No 02.665.10.0.00 , Fuel Pump: Ha294 Cmvr Stage I Cart Part No 02.687.01.0.00 , Piston Assly 3 Ring Cmvr-Ii Cart Part No 02.689.30.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 02.692.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 02.692.02.0.00 , Fuel Pipe (Fuelfilter To Fuel Pump) Cart Part No 02.692.06.0.00 , Fuel Pipe(Feed Pump To Fuel Filter) Cart Part No 02.692.07.0.00 , Control Panel Assly Foriraq,With Electrical Lop/Lot Gause Cart Part No 02.700.10.0.00 , 12 V Dcrelay Board Two Relay Cart Part No 02.701.02.0.00 , Genset Control Unit Ems 927V3 V4 Cart Part No 02.709.05.0.00 , Glass Fuse 1Amp 20 Mm Cart Part No 02.709.22.0.00 , Super Capacitor 120F Ga Drawing With Mounting Cart Part No 02.709.27.0.Pr , Fuel Pipe Pre-Filter To Tank Cart Part No 02.712.06.0.00 , 12V Dc,110Ah,Smf Battery,Model :Smf N100 Cart Part No 02.731.40.0.00 , Fuel Inlet Pipe Cart Part No 02.751.12.0.00 , Fuel Inlet Pipem14x1 5 Banjo And M16x1 5 Union Nut Cart Part No 02.751.21.0.Pr , Plastic Fuel Spout And Cap Cart Part No 02.752.41.0.00 , Emergency Stop Push Button Protection Cart Part No 02.759.13.0.00 , Emergency Push Button With No Contactnon Lachable Cart Part No 02.759.14.0.Pr , Left Hand Lock With Catcher Padlock Arrangementupto 10 Kva Cart Part No 02.759.21.0.Pr , Right Hand Lock With Catcher Padlock Arrangementupto 10 Kva Cart Part No 02.759.22.0.Pr , Lever Lock For Canopy Cart Part No 02.759.23.0.Pr , Left Hand Lock With Catcher & Padlock Arrangement (Relience_Infra) Cart Part No 02.759.31.0.Pr , Right Hand Lock With Catcher & Padlock Arrangement (Relience_Infra) Cart Part No 02.759.32.0.Pr , Fuse Terminal Cart Part No 02.771.39.0.00 , Diode Forword Bais For Kg15st To Kg30st Alternator Type Cart Part No 02.804.12.0.00 , Diodereverse Bais For Kg15st To Kg30st Alternator Type Ta3a3 Cart Part No 02.804.13.0.00 , Excitor Rotor Assembly For Kg15st To Kg30st Alternator Type Ta3a5 Cart Part No 02.804.15.0.00 , Terminal Block: Kg15st-30St Cart Part No 02.804.21.0.00 , Rra Condenser Diode, Varistor Cart Part No 02.811.01.0.Asp , Sae 3, De Brkt- Prot. Screen Asly ? Kg28. Kva Rating:- (15-20, 1Ph & 20-30, 3Ph) Cart Part No 02.811.03.0.Asp , Excitor Stator-15/20 Kva 1 Phase Cart Part No 02.811.05.0.Asp , Exciter Rotor Cart Part No 02.811.06.0.Asp , Coupling Disc Set With Hardware- 15/20 Kva 1 Phase Cart Part No 02.811.09.0.Asp , Engine Wiring Harness Assembly Cart Part No 02.840.50.0.00 , Engine Wiring Harness Assly With Fuel Level Gems Sensor Cart Part No 02.840.60.0.00 , Junction Box (Ip55) Assembly Cart Part No 02.845.55.0.Pr , Lube Oil Pressure Switch Cart Part No 02.846.11.0.00 , Lube Oil Pressure Switch Cart Part No 02.846.12.0.Pr , Engine Wiring Harness Assembly Cart Part No 02.846.60.0.00 , Engine Wiring Harness Ha294 Sf Gc 2111 Unit Cart Part No 02.846.95.0.Pr , Engine Wiring Harness For 15Kva Ha2 Emerald Cart Part No 02.847.30.0.Pr , Engine Wiring Harness For 20Kva 1Ph Genset-Rjio Cart Part No 02.851.20.0.Pr , 12V Relay Board 1A-70A Cart Part No 02.854.57.0.00 , Nylon Cable Tie, Length: 1 Cart Part No 02.857.19.0.00 , 3 Phase 12V Rear Mounting W/O Display Cart Part No 02.859.06.0.00 , 1 Phase 12V Rear Mounting W/O Display Lvm Koel Cart Part No 02.859.09.0.00 , 12 Vdc Relay Board Three Channel Cart Part No 02.870.05.0.00 , Battery Charger 10A 12 Vdc Cart Part No 02.872.18.0.00 , Battery Charger 10A 12Vdc Cart Part No 02.872.22.0.Pr , 4 Pole 50 Amp Mcb Cart Part No 02.887.03.0.00 , Koel Green Alternatorkg 15 S Sframel Kg 42 3 Asae 2 11 5 230V50 Hz0 8 Pf Cart Part No 02.901.01.0.Pr , Koel Green Alternatorkg 15 S T Framel Kg 40 Esae 2 11 5 415V50 Hz0 8 Pf Cart Part No 02.901.03.0.Pr , Wiring Harness With Socket Cart Part No 02.910.10.0.00 , Wiring Harness From Engine To Amf Panel In Canopy Cart Part No 02.913.20.0.00 , Wiring Harness: 15Kva Cart Part No 02.920.20.0.00 , Fuel Tank Unit With 356 Effective Height Cart Part No 02.928.50.0.Pr , Assembly Of Air Guide Ring & Brush Cart Part No 02.930.10.0.00 , Wiring Harness Assly S/F Ha2 Cart Part No 02.935.10.0.00 , Wiring Harness Assly With Cld Cart Part No 02.938.20.0.00 , Wiring Harness Assly Cart Part No 02.938.70.0.00 , Current Transformer Cart Part No 02.944.08.0.00 , Double Pole Mcb 6A Cart Part No 02.944.11.0.00 , Power Terminal 50 Sq Mm Cart Part No 02.944.78.0.00 , Glass Fuse Link 15A 20 Mm Cart Part No 02.945.08.0.00 , Battery Tester Ut675a Uni T Cart Part No 02.950.05.0.Sp , Battery Cable Assembly21 Sq.Mm Cart Part No 02.950.10.0.00 , Control Panel Assembly Ha Ve Ve Cart Part No 02.958.10.0.Pr , Wiring Harness: Ha294 Industrial Va/Ve Cart Part No 02.958.30.0.00 , Control Panel Assembly Ha Va Ve Oem Based Cart Part No 02.959.10.0.Pr , Wiring Harness Assembly Ha294 Va Ve Oem Based Cart Part No 02.959.30.0.00 , 4Pin Powermate Male Housing Cart Part No 02.961.14.0.00 , 6Pin Powermate Male Housing Cart Part No 02.961.15.0.00 , 6 Pin Connector Cart Part No 02.961.16.0.00 , Connector Assembly For Control Panel With L0 Controller Cart Part No 02.961.60.0.00 , Single Pole Mcb 10A (A9n1p10c) Cart Part No 02.974.37.0.00 , Mccb100aftfm4pole Spreader Kit Cart Part No 02.974.77.0.Pr , Dse2157 Dsenet Output Expansion Module Cart Part No 02.991.33.0.00 , B Kit Overhaul Ha294 - Ktl Cart Part No 02.999.11.0.00 , Push Rod Kit: Ha2 Cart Part No 02.999.13.0.00 , One Time Filter Kit 0.5 Ltr Cart Part No 02.999.17.0.00 , Ha 294 (Pg) Service Kit - B Check Cart Part No 02.999.35.0.00 , Ha294 Sr Ii/394 Pg Serv Kit B Chk Cart Part No 02.999.36.0.00 , Ha294 (Pg) Service Kit With Air Filter C Chk Cart Part No 02.999.37.0.00 , Ha294 Sr Ii Pg Service Kit With Air Filter -C Check Cart Part No 02.999.38.0.00 , Wet Pm Kit (W/O Oil) For 02.2129,02.8303,02.2147,02.2122,02.8302,02.8312,02.8314 - Ha294 Cart Part No 02.999.38.0.Sp , Wet Pm Kitw O Oilfor 15Kva 02 8301 Ha294 G1 Cart Part No 02.999.45.0.Sp , Wet Pm Kit (W/O Oil) For 02.2119 ,02.2115-Ha-294 Cart Part No 02.999.46.0.Sp , Wet Pm Kit (W/O Oil) For 02.8306,02.8323,02.8331,02.8336,02.2129,02.9020,02.9006,02.8314,02.8 Cart Part No 02.999.48.0.Sp , Wet Pm Kit (W/O Oil) For 03.1143, 03.1176, 03.2004 - Ha394 Cart Part No 02.999.57.0.Sp , Half Overhaul Kit For Ha494 Cart Part No 02.999.60.0.00 , Wet Pm Kit (W/O Oil) For 02.2109.10 - Ha294 Cart Part No 02.999.78.0.Sp , Major Overhaul Kit Cart Part No 02.999.80.0.00 , Wet Pm Kit (W/O Oil) For 02.1144, 02.1158, 02.1204 - Ha294 Cart Part No 02.999.83.0.Sp , Wet Pm Kit (W/O Oil) For 02.1143, 02.1186 - Ha294 Cart Part No 02.999.84.0.Sp , Wet Pm Kit (W/O Oil) For 02.2133... - Ha2 Cart Part No 02.999.85.0.Sp , Wet Pm Kit (W/O Oil) For 02.2119 - Ha294 Cart Part No 02.999.86.0.Sp , Wet Pm Kit (W/O Oil) For 03.8906 - Ha394 Cart Part No 02.999.87.0.Sp , Conversion Kit From Kg 934 To Kg 645 Cart Part No 02.999.91.0.Sp , Conversion Kit From Kg 541 To Kg 645 For Dc Card Cart Part No 02.999.92.0.Sp , Conversion Kit From Kg 541 To Kg 645 For Ac+Dc Card Cart Part No 02.999.93.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Dc Card Cart Part No 02.999.94.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Ac+Dc Card Cart Part No 02.999.95.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Chhota Chilli Cart Part No 02.999.96.0.Sp , Negative Insulated Starter 12 Vdc, 2 Wire - 2.7Kw Cart Part No 02.M801.09.0.00 , Cylinder Head Temperature Sensors Cart Part No 02.M801.10.0.00 , Cam Bush Cart Part No 03.001.04.0.00 , Screw Plug Cart Part No 03.001.06.0.00 , Slotted Pin Cart Part No 03.001.07.0.00 , Deflector Plate Cart Part No 03.001.08.0.00 , Precoated Stud (For Fuel Pump Mounting) Cart Part No 03.001.12.0.00 , Thrust Washer -Drive End,Top Cart Part No 03.001.19.0.00 , Thrust Washer (Drive End,Bottom) Cart Part No 03.001.21.0.00 , Bolt : Mb Cap Hex Head M14x2x128 Cart Part No 03.001.22.0.00 , Washerfor Fuel Pump Mounting Cart Part No 03.001.25.0.00 , Crankcase Assly W O Bearings Cart Part No 03.001.50.0.00 , Gasket: Fuel Pump Cart Part No 03.003.11.0.00 , Overflow Valve Assly Cart Part No 03.003.60.0.00 , Crankshaft Gear Cart Part No 03.005.02.0.00 , Thrust Washer For Camshaft Cart Part No 03.006.02.0.00 , Bush For Tachometer Cart Part No 03.006.03.0.00 , Camshaft Gear Cart Part No 03.006.04.0.00 , Camshaft & Gear Assly Cart Part No 03.006.10.0.00 , Oil Seal Housing: F Cart Part No 03.007.01.0.00 , Joint For Oil Seal Hsg Cart Part No 03.007.04.0.00 , Oil Seal(115X140x12) Cart Part No 03.007.06.0.00 , Rotary Shaft Seal Teflon Cart Part No 03.007.91.0.00 , Intermediate Gear Support Cart Part No 03.008.05.0.00 , Split Bush : Support Cart Part No 03.008.06.0.00 , Intermediate Gear Assly Cart Part No 03.008.10.0.00 , Screen Plate Cart Part No 03.010.02.0.00 , O Ring: L.O. Pump 1.57X65 - 21508 Cart Part No 03.010.11.0.00 , Relief Valve Cart Part No 03.010.13.0.00 , Spring: Relief Valve Cart Part No 03.010.14.0.00 , Lube Oil Pump Assly With Drvg Gear Cart Part No 03.010.50.0.00 , Union Screw Cart Part No 03.011.02.0.00 , Double Cone Ring Cart Part No 03.011.03.0.00 , Clip For Pipe Cart Part No 03.011.04.0.00 , O Ring: Delivery Tube: 3X14- 21508 Cart Part No 03.012.02.0.00 , Yoke Spring (Pipe Clamp) Cart Part No 03.012.04.0.00 , Delivery Tube Cart Part No 03.012.11.0.00 , Cover Cart Part No 03.013.03.0.00 , O Ring: 3X78 Silicone Cart Part No 03.013.04.0.00 , Joint: Front Cover Cart Part No 03.013.05.0.00 , Oil Seal (65X85x13) Cart Part No 03.013.06.0.00 , O Ring (3.2 X 78 Silicon) Cart Part No 03.013.11.0.00 , Joint For Front Cover( Asbestoss Free) Cart Part No 03.013.12.0.00 , Rotary Shaft Seal(Ge) Teflon Cart Part No 03.013.91.0.00 , Tachometer Plug Cart Part No 03.014.05.0.00 , Spring For Cup Cart Part No 03.014.06.0.00 , Sub Assembly Of Spring & Tachodrive Cup Cart Part No 03.014.10.0.00 , Bolt: Crank Pulley Updated 110Mm Cart Part No 03.016.02.0.00 , Washer: Crank Pulley Bolt Cart Part No 03.016.03.0.00 , Breather Tube Cart Part No 03.017.06.0.00 , Lower Cowling Cart Part No 03.019.01.0.00 , Rubber Grommet Cart Part No 03.019.05.0.00 , Union Screw Cart Part No 03.020.02.0.00 , Double Cone Ring Cart Part No 03.020.03.0.00 , Rubber Bush Cart Part No 03.020.05.0.00 , Spacer Cart Part No 03.020.06.0.00 , Sealing Ring Cart Part No 03.020.08.0.00 , Front Cowling Cart Part No 03.021.01.0.00 , Top Air Baffle Cart Part No 03.022.01.0.00 , Rubber Grommet Cart Part No 03.022.02.0.00 , Rubber Grommet Cart Part No 03.022.03.0.00 , Rear Cowling Cart Part No 03.023.01.0.00 , Special Plain Washer - M6 Cart Part No 03.023.02.0.00 , Assly Of Exh Air Baffle & Screen Plate Cart Part No 03.024.20.0.00 , Fan Pulley98 Pcda Section2 Grooves Cart Part No 03.025.15.0.00 , Assly Of Cooling Blower Cart Part No 03.025.40.0.00 , Banjo Bolt Cart Part No 03.027.04.0.00 , Leak Off Pipe Cart Part No 03.027.07.0.00 , Leak Off Pipe Assly Cart Part No 03.027.10.0.00 , Leak Off Pipe Sub Assly Cart Part No 03.027.20.0.00 , Cowling Assly: Welded Cart Part No 03.029.10.0.00 , Spacer(11 X 18 X18 L ) Cart Part No 03.030.05.0.00 , Screen Plate Assembly Cart Part No 03.033.10.0.00 , Starter 12V Cart Part No 03.034.01.0.00 , Starter Ring 121T 3.175Mod Cart Part No 03.035.02.0.00 , Bolt : Flywheel M10x35 Long Cart Part No 03.035.03.0.00 , O Ring: Dipstick 2X5 21515 Cart Part No 03.036.01.0.00 , Dipstick Assly Cart Part No 03.036.10.0.00 , Inlet Manifold Cart Part No 03.037.01.0.00 , V Belt A49 1278 Length Cart Part No 03.037.04.0.00 , Sealing Ring: Bowl 89X102x3.2T Cart Part No 03.040.03.0.00 , Banjo Bolt Cart Part No 03.040.06.0.00 , Joint: Lube Filter Asbestos Free Cart Part No 03.040.07.0.00 , Lube Oil Filter Header Cart Part No 03.040.11.0.00 , Lube Oil Filter Element Cart Part No 03.040.19.0.00 , Mounting Assly: Lube Oil Filter Cart Part No 03.041.10.0.00 , Blanking Plate Cart Part No 03.047.01.0.00 , Mud Slingerge Side Cart Part No 03.049.07.0.00 , Flywheel Bolt: M10x50 Cart Part No 03.050.02.0.00 , Flywheel Assembly Cart Part No 03.050.10.0.00 , Flywheel Assembly Cart Part No 03.050.20.0.00 , Flywheel Assembly Cart Part No 03.050.75.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No 03.052.03.0.00 , Bracket For Fuel Filter Cart Part No 03.052.06.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 03.052.07.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Inlet Cart Part No 03.052.08.0.00 , Fuel Pipe ( Feed Pump To Fuel Filter) Cart Part No 03.052.11.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 03.052.12.0.00 , V Belt A49 1278 Length Cart Part No 03.054.01.0.00 , Gear End Foot Cart Part No 03.056.01.0.00 , Crankcase Foot Cart Part No 03.057.01.0.00 , Belt Guard Cart Part No 03.059.01.0.00 , Spacer For Belt Guard On Front Cover Cart Part No 03.059.03.0.00 , Spacer For Belt Guard On Bt Unit Cart Part No 03.059.04.0.00 , Hex Spacer For Belt Guard On Ge Foot Cart Part No 03.059.05.0.00 , Support For Belt Guard On Fan Body Cart Part No 03.059.06.0.00 , Spacer: Belt Guard Cart Part No 03.060.05.0.00 , Washer Cart Part No 03.060.08.0.00 , Support For Belt Guard On Fan Body Cart Part No 03.060.11.0.00 , Air Cleaner Assly Cart Part No 03.061.20.0.00 , Air Cleaner Clamp Cart Part No 03.061.21.0.00 , Bowl Cart Part No 03.061.22.0.00 , Sealing Ring Cart Part No 03.061.23.0.00 , Cone Ring Bet Bowl&Preclean Cart Part No 03.061.26.0.00 , Pre Cleaner For Air Cleaner Cart Part No 03.061.40.0.00 , Oil Bath Air Cleaner With Rubber Sleeve Cart Part No 03.061.70.0.00 , Bracket: Air Cleaner Cart Part No 03.063.01.0.00 , Hose For Air Cleaner: 70 Idx 80L Cart Part No 03.063.02.0.00 , Bracket Cart Part No 03.064.05.0.00 , Link For Ball Joint Cart Part No 03.064.07.0.00 , Bush Cart Part No 03.064.09.0.00 , Washer For Stopping Lever Cart Part No 03.064.11.0.00 , Sub Assembly Of Engine Stopping Lever Cart Part No 03.064.20.0.00 , Knurled Nut Cart Part No 03.065.04.0.00 , Spherical Washer Cart Part No 03.065.05.0.00 , Assly Speed Adjustment Unit S/F Cart Part No 03.065.30.0.00 , Adaptor: Temp Gauge Cart Part No 03.067.01.0.00 , Set Of Joints Cart Part No 03.068.10.0.Sp , Set Of Washers Cart Part No 03.068.12.0.00 , Set Of O Rings: Ha394 Cart Part No 03.069.10.0.00 , Set Of Copper Washer Cart Part No 03.069.30.0.00 , Gear End Foot Cart Part No 03.071.01.0.00 , Flywheel End Foot Fil Side Cart Part No 03.072.01.0.00 , Adaptor: Spin On Lof Cart Part No 03.075.10.0.00 , Lifting Hook Cart Part No 03.076.02.0.00 , O Ring: B.T. Unit 4X18-21511 Cart Part No 03.080.03.0.00 , B.T. Unit Sub Assly Cart Part No 03.080.90.0.00 , Belt Tension Unit With Actuator Cart Part No 03.080.91.0.00 , Leak Off Pipe Assly Cart Part No 03.081.10.0.00 , Cover For Flywheel Housing Cart Part No 03.086.02.0.00 , Flywheel Housing Cart Part No 03.086.03.0.00 , Gas Mixer Cart Part No 03.086.11.0.Pr , Crank Pulley Cart Part No 03.087.01.0.00 , Spacer ( 11 X 20 X 9 L ) Cart Part No 03.088.03.0.00 , Belt Tensioning Pulleyassembly Cart Part No 03.093.110.0.00 , B.T. Unit Assembly With Actuator Cart Part No 03.093.160.0.Pr , B.T. Unit Sub Assly Cart Part No 03.093.90.0.00 , Belt Tension Unit With Actuator Cart Part No 03.093.91.0.00 , Belt Tension Sub Assly With Actuator Cart Part No 03.093.92.0.00 , B.T. Unit Assembly With Actuator Cart Part No 03.093.93.0.00 , B.T. Unit Sub Assly & Actuator Cart Part No 03.093.94.0.00 , Rocker Cover Cart Part No 03.095.01.0.00 , Adaptor For Extension Shaft Cart Part No 03.096.01.0.00 , Rear Cowling Cart Part No 03.105.01.0.00 , Ducting & Cover Assembly For Hydraulic Cooler Cart Part No 03.106.20.0.00 , Bracket: Alternator Cart Part No 03.107.02.0.00 , Spacer (11X20x24 L ) Cart Part No 03.107.04.0.00 , Spacer ( 9X20x21l ) Cart Part No 03.107.05.0.00 , Flywheel Housing Cart Part No 03.108.03.0.00 , Special Washer Cart Part No 03.109.03.0.00 , Plate For Fuel Filter Cart Part No 03.113.01.0.00 , Plate For Fuel Filter Cart Part No 03.113.02.0.00 , Joint: Exhaust Bend Cart Part No 03.114.02.0.00 , Pin Cart Part No 03.117.02.0.00 , Adaptor For Tachodrive Cart Part No 03.117.04.0.00 , U Clamp Cart Part No 03.119.04.0.00 , Clamping Plate ( For U Clamp) Cart Part No 03.119.05.0.00 , Exhaust Manifold: Silencer With Clamp Cart Part No 03.119.20.0.00 , Rain Cap Sub Assly Cart Part No 03.120.20.0.00 , Rain Cap Sub Assly Cart Part No 03.120.30.0.00 , Sub Assembly Of Bend & Rain Cap Cart Part No 03.120.40.0.00 , Spacer Cart Part No 03.121.05.0.00 , Plate For Stopping Bar Cart Part No 03.121.06.0.00 , Sub-Assembly Of Guide Plate & Torsion Spring Cart Part No 03.121.20.0.00 , Ammeter -(50-0-50)Amps Cart Part No 03.124.01.0.00 , Alternator Pulley: 24V Cart Part No 03.128.01.0.00 , Bracket: Alternator Mtg Cart Part No 03.128.02.0.00 , Damping Bush Cart Part No 03.128.03.0.00 , Tension Adjusting Lever Cart Part No 03.128.06.0.00 , Bracket For Alternator Cart Part No 03.128.08.0.00 , Alternator: 24V Cart Part No 03.130.01.0.00 , Fan Pulley (82 Pcd, A Section, 2 Grooves) Cart Part No 03.135.04.0.00 , Impeller With Bush (Updated) Cart Part No 03.135.10.0.00 , Assly Of Cooling Blower Cart Part No 03.135.40.0.00 , Fan Body Stator & Impell Sub Assly Cart Part No 03.135.60.0.00 , Exhaust Fan, 12, 230Vac, 1400Rpm. Cart Part No 03.137.06.0.00 , Start Push Button Cart Part No 03.147.16.0.00 , Stop Push Button, (Xb5 Aa42n + 1No) Cart Part No 03.147.19.0.00 , Alternator: 12V 35A Cart Part No 03.148.05.0.00 , F002 G1b 704Chargine Alternator 12V, 35Amp With 2 Wire System Cart Part No 03.148.70.0.00 , Alternator Pulley F: 81 Pcd Cart Part No 03.149.01.0.00 , Spacer(11 X 20 X 6.5 L) Cart Part No 03.149.02.0.00 , Tension Adjusting Lever Cart Part No 03.149.03.0.00 , Spacer Cart Part No 03.180.08.0.00 , Spacer For Hot Air Ducting Cart Part No 03.180.12.0.00 , Spacer (Bar) Cart Part No 03.182.02.0.00 , Assembly A V Mtg Cart Part No 03.190.10.0.00 , Spacer Cart Part No 03.192.02.0.00 , Bracket For Stopping Bar Cart Part No 03.199.01.0.00 , Bracket For Prressure Gauge Sendor Unit Cart Part No 03.203.01.0.00 , Air Cleaner Bracket Cart Part No 03.203.25.0.00 , Hose: Air Cleaner Cart Part No 03.203.29.0.00 , Reducer Hose For Air Cleaner Cart Part No 03.203.33.0.00 , Exhaust Diffuser Cart Part No 03.203.34.0.00 , Hose For Air Cleaner Cart Part No 03.203.56.0.00 , Adaptor For Inlet Connection Cart Part No 03.208.02.0.00 , Wet Pm Kit (W/O Oil) For 03.2107,03.2145 Cart Part No 03.210.7.0.Sp , Rotex Solenoid Operated Fuel Magnet Valve Cart Part No 03.215.83.0.00 , Reciprocating Air Compressor Cart Part No 03.215.98.0.00 , Air Cleaner For Ha3 Engine Cart Part No 03.216.71.0.00 , 1 2Inch Bsp Straightmale Adaptor Length 42Mm A F 22 25Mm Id 14Mm Cart Part No 03.216.86.0.00 , Automatic Voltage Regulatoravr Cart Part No 03.217.24.0.00 , Fueltank For 7.5 Kw Apu Cart Part No 03.217.28.0.00 , Fuel Level Sensor Cum Switch Cart Part No 03.217.29.0.00 , Vulkan Coupling (Vulastik-Coupling Between Alternator & Compressor) Cart Part No 03.218.87.0.00 , Engine Wiring Harness For Hhp Apu Cart Part No 03.219.21.0.00 , Solenoid Drain Valve Kit Cart Part No 03.219.27.0.00 , Vulkan Coupling Between Alternator Compressor Megiflex B Coupling 1040S Cart Part No 03.219.49.0.00 , 1 Inch Bspp Swivel Elbowone Side Male One Side Swivel Female Cart Part No 03.219.57.0.00 , 1 2 Inch Bsp 90 Degelbowboth Side Malemoc Forged Steel 1000Psi Cart Part No 03.219.58.0.00 , Air Filterinsert Cart Part No 03.221.129.0.Sp , Air Filter Cart Part No 03.221.39.0.00 , 72V Dc Coil For 2 2 Direct Acting Normally Closed Solenoid Valvesolenoid Valv Cart Part No 03.221.66.0.00 , Fuel Strainer Cart Part No 03.222.62.0.00 , Vulkan Coupling (Vulastik-Coupling Between Alternator & Compressor) Cart Part No 03.222.95.0.00 , Exhaust Fan (450Mm) With Connector Cart Part No 03.224.01.0.00 , Exhaust Fan 15230V50hzflow Direction Motor To Blade Cart Part No 03.224.17.0.Pr , Current Transformer 30 52 5 Va Cart Part No 03.231.09.0.00 , Cam Shaft & Gear Assembly Cart Part No 03.236.10.0.00 , Cam Shaft & Gear Assembly Cart Part No 03.236.20.0.00 , Camshaft & Gear Assembly Cart Part No 03.236.40.0.00 , Flange For Starter Cart Part No 03.238.01.0.00 , Metalic Breather Pipe (Long) Cart Part No 03.239.01.0.00 , Mushroom Push Button Model Nozb5ac4with No Contact And Collar Cart Part No 03.240.82.0.00 , Amf65 Apu Controllertypeapumaster7 5Kw Cart Part No 03.240.83.0.00 , Amf65 Apu Controllertypeapuslave7 5Kw Cart Part No 03.240.84.0.00 , Fuel Pump Cart Part No 03.247.10.0.00 , Fuel Pipefilter Leak Off To Tank Cart Part No 03.248.02.0.Pr , Nozzle To Nozzle Leak Off Pipe Cart Part No 03.248.20.0.00 , Leak Off Pipe (Nozzle Leak Off To Filter Leak Off) Cart Part No 03.248.60.0.00 , Diode Forrectifier Unit Cart Part No 03.250.81.0.00 , Diode Forrectifier Unit Cart Part No 03.250.82.0.00 , Power Contactorac1 160A 48 130Vdcmodel No Af116 30 11 Cart Part No 03.250.93.0.00 , Power Contactor3p72v Dc Cart Part No 03.250.94.0.00 , Drain Pipe For Lub Oil Sump 320 Mm Cart Part No 03.254.07.0.00 , Anti Vibration Mounts Cart Part No 03.274.01.0.00 , Non Return Valve Cart Part No 03.291.13.0.00 , Adaptor M16x1.5 To 1/4 Bsp Cart Part No 03.291.16.0.00 , Pulley: Alternator 24V Spz Cart Part No 03.294.01.0.00 , Engine Wiring Harness Assembly Cart Part No 03.312.90.0.00 , Engine Wiring Harness Assembly Cart Part No 03.313.40.0.00 , Engine Wiring Harness Ha394with Rotry Pump Cart Part No 03.314.50.0.Pr , Stanadyne Rotary Fip For Ha394 Tci 40Hp 1500Rpmcpcbiiengine Cart Part No 03.340.04.0.00 , Inline Fip For Ha394tci G1 Engine -32 Hp @ 1500 Rpm Cart Part No 03.340.07.0.00 , Engine Wiring Harness Assembly(Without V Belt) Cart Part No 03.360.10.0.00 , Wiring Harness Cart Part No 03.360.20.0.00 , Silicon Coated Fiber Glass Clothsize After Forming 18X 14X 13With Fittings Cart Part No 03.423.51.0.00 , Assembly Of Hot Air Ducting ( Combined - Upward Open ) S/F Ha 394 Cart Part No 03.485.10.0.00 , Hot Air Ducting Assly: Side Open Cart Part No 03.485.20.0.00 , Wiring Harness With Pump Mounted Stop Solenoid Cart Part No 03.489.10.0.00 , Fuel Tank Assembly Cart Part No 03.503.10.0.00 , Bracket For Vsc Unit Cart Part No 03.508.01.0.00 , Bracket: Fixed Speed Ha294 Cart Part No 03.508.13.0.00 , Sub Assly Of V S Unit On F P Cart Part No 03.520.10.0.00 , Exhaust Mfold: Central Open Cart Part No 03.530.01.0.00 , Sub Assembly Of Exhaust Manifold And Adaptor Cart Part No 03.530.10.0.00 , Lube Oil Press Gauge Pipe 1.3M Cart Part No 03.593.01.0.00 , O Ring: Compressor Cart Part No 03.609.15.0.00 , O Ring: Cover Plate Cart Part No 03.609.17.0.00 , Cover Plate For Compressor Cart Part No 03.609.19.0.00 , Lub Oil Supply Pipe Assemblyccase To Comp Cart Part No 03.609.60.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 03.635.16.0.00 , Fuel Return Pipe Cart Part No 03.635.17.0.00 , Fuel Pipefeed Pump To Tank Unit Cart Part No 03.635.36.0.00 , Clamp For Dip Stick Guide Cart Part No 03.648.01.0.00 , Raised Dipstick Assly Cart Part No 03.648.50.0.00 , Du Fuel Filter 1.1 L W/O Valve Cart Part No 03.656.20.0.00 , Special Banjo Bolt(Losupply To Pump) Cart Part No 03.660.07.0.00 , Fuel Pump Assly Cart Part No 03.660.10.0.00 , Snap On Terminal Dowel Cart Part No 03.665.05.0.00 , Hub For Fuel Pump Gear Cart Part No 03.716.01.0.00 , Fuel Pump Gear Cart Part No 03.716.02.0.00 , Washer Fuel Pump Gear Cart Part No 03.716.03.0.00 , Eccentric Ring For Fip Gear Cart Part No 03.716.07.0.00 , Leak Off Pipe Assly Cart Part No 03.721.10.0.00 , Set Of High Press Pipe: Dha394 Cart Part No 03.723.90.0.00 , Front Cover Cart Part No 03.731.01.0.00 , Front Cover Cart Part No 03.731.05.0.00 , Inlet Cap For Oil Bath Air Cleaner Cart Part No 03.732.01.0.00 , Exhaust Manifold To Suit Tr 43 Turbo Charger Cart Part No 03.734.03.0.00 , Hose (Compressor Out) Cart Part No 03.734.04.0.00 , Lub Oil Drain Pipefront Cover Side Cart Part No 03.736.04.0.00 , Lub Oil Drain Pipeturbo Side Cart Part No 03.736.05.0.00 , Lube Oil Cooler- Aluminium Cart Part No 03.750.01.0.00 , Cac-In Pipe Assembly (Cac-Side) Cart Part No 03.752.10.0.00 , Adaptor: Press Gauge Sendor Cart Part No 03.769.02.0.00 , Joint For Cover Cart Part No 03.774.04.0.00 , Lube Oil Sump: Flat Face Cart Part No 03.829.30.0.00 , Suction Tube Cart Part No 03.830.20.0.00 , Wiring Harness Ha394 P.G.Engine With Alt Cart Part No 03.842.20.0.00 , Wiring Harness: Engine To Control Panel Cart Part No 03.907.20.0.00 , Adapter Ring For Sae1 To Sae2 Cart Part No 03.910.01.0.00 , Crankshaft Assly With Cr Gear Cart Part No 03.913.30.0.00 , Crankshaft Assembly Cart Part No 03.913.40.0.00 , Engine Start Push Button Cart Part No 03.918.17.0.00 , Engine Stop Push Button Cart Part No 03.918.18.0.00 , Fuel Filter 0.5 L Wo O-Ring Cart Part No 03.922.10.0.00 , Spinon Fuel Filter 0.6L Sbowl Cart Part No 03.922.40.0.00 , Fuel Filter Element Cart Part No 03.922.42.0.00 , Adaptor For Pricol Lube Oil Pressure Sensor Cart Part No 03.924.01.0.00 , Wiring Harness Assembly Ha3 Cart Part No 03.943.20.0.00 , Fuel Pump Variable Speed_ Ha394 Cmvr Stage I Cart Part No 03.947.01.0.00 , Punch For Disc Plug Cam Bore Cart Part No 03.950.20.0.00 , Mandrel For Oil Seal Ge Cart Part No 03.950.21.0.00 , Engine Safety Unit (Krb 203A With Timer For Cold Starting Aid) Cart Part No 03.963.02.0.00 , Off/On Selector Switch Cart Part No 03.963.19.0.00 , Selector Switch 2Way Cart Part No 03.963.22.0.00 , Emergencyswitch Cart Part No 03.963.23.0.00 , Flywheel Housing Cart Part No 03.974.01.0.00 , Flywheel Housingsae3 Cart Part No 03.974.03.0.00 , B Kit Overhaul Ha394 - Ktl Cart Part No 03.999.15.0.00 , Push Rod Kit: Ha3 Cart Part No 03.999.20.0.00 , Wet Pm Kit (W/O Oil) For 03.2106, 03.9003, 03.8803,03.8901, 03.8902, 03.8903 - Ha394 Cart Part No 03.999.25.0.Sp , Wet Pm Kit (W/O Oil) 03.2001, 03.2015 - Ha394 Cart Part No 03.999.27.0.Sp , Wet Pm Kit (W/O Oil) For 02.1174 - Ha294 Cart Part No 03.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 03.107 - Ha394 Cart Part No 03.999.29.0.Sp , Ha394 Pg Service Kit With Air Filter C Check Cart Part No 03.999.35.0.00 , Wet Pm Kit (W/O Oil) For 03.2105 - Ha394 Cart Part No 03.999.89.0.Sp , Precoated Screw Plug Cart Part No 04.001.08.0.00 , Ccase Assly W/O Bearing Cart Part No 04.001.90.0.00 , Socket Head Bolt: M12x1.75X60 -10.9 Cart Part No 04.005.12.0.00 , Camshaft & Gear Assembly Cart Part No 04.006.30.0.00 , Camshaft And Gear Asslycmvr Stage Iii Cart Part No 04.006.40.0.00 , Comb Leak Off S/F Pipes: Ha4 Cart Part No 04.008.01.0.00 , Sub Assembly Leak Off Pipe (Industrial) Cart Part No 04.010.20.0.00 , Suctiontubesubassembly Cart Part No 04.011.40.0.00 , Exhaust Air Baffle Cart Part No 04.014.01.0.00 , Inlet Manifold Cart Part No 04.016.01.0.00 , Lower Cowling Cart Part No 04.019.01.0.00 , Lower Cowling For Ha494t Bs Iii Cart Part No 04.019.03.0.00 , Lube Oil Cooler Cart Part No 04.020.01.0.00 , O Ring: Lube Oil Cooler 2.5X26 -21502 Cart Part No 04.020.02.0.00 , Lube Oil Cooler: Ha494tc Cart Part No 04.020.03.0.00 , Top Air Baffle Cart Part No 04.021.01.0.00 , Upper Cowling Welded Assly Cart Part No 04.022.10.0.00 , Bolt: Flywheel-M10x45 Lg Cart Part No 04.024.02.0.00 , Subassembly Of Fw&Starter Ring Cart Part No 04.024.10.0.00 , Flywheel(C-108 Pto,Flexible Coup.Centa) Modified For Width Cart Part No 04.024.20.0.00 , Spacer (11X20x13.8L) Cart Part No 04.028.02.0.00 , Washer (Top) Cart Part No 04.030.02.0.00 , Anti Vibration Mounts Assly Cart Part No 04.030.20.0.00 , Torsional Vibration Damper Cart Part No 04.031.02.0.00 , Joint Cart Part No 04.032.02.0.00 , Hydraulic Pump Gear Cart Part No 04.032.03.0.00 , Lock Nut Cart Part No 04.032.04.0.00 , Flange Cart Part No 04.032.05.0.00 , O Ring Suction Flange 2 65X23 6I D Cart Part No 04.032.06.0.00 , Flange (Small) For Hyd Pump Cart Part No 04.032.07.0.00 , O Ring Del Flange2 5X19 21507 Cart Part No 04.032.08.0.00 , Ferrule For Delivery Pipe Cart Part No 04.032.12.0.00 , Flange (Outlet) Cart Part No 04.032.14.0.00 , Set Of Joints Cart Part No 04.034.10.0.Sp , Set Of Joints Cart Part No 04.034.20.0.Sp , Set Of O Rings Ha494 Cart Part No 04.035.10.0.00 , Plate For A V Mounting Cart Part No 04.037.01.0.00 , Flywheel Assly Cart Part No 04.039.10.0.00 , Bracket: Fuel Filter Cart Part No 04.040.04.0.00 , Stopping Bar Assembly Cart Part No 04.051.50.0.00 , Exhaust Mfold Cum Silencer Cart Part No 04.052.30.0.00 , V Belt : A48x 1252 Long Cart Part No 04.062.01.0.00 , Spacer: Bottom A V Mtg Cart Part No 04.080.01.0.00 , Assly Of Cooling Blower Cart Part No 04.081.10.0.00 , Fuel Pipe 80,14X14b,235 Cart Part No 04.089.01.0.00 , Flexible Pipe Lop Gauge (2.5 M Long) Cart Part No 04.091.01.0.00 , V Belt: Failure Switch Khd-224 5023 Cart Part No 04.106.01.0.00 , Hot Air Ducting Assly Cart Part No 04.108.10.0.00 , Exhaust Mfold: Ha4 Finish Cart Part No 04.110.01.0.00 , Start Key Switch Cart Part No 04.135.02.0.00 , Flywheel Assembly Cart Part No 04.135.10.0.00 , V Belt: A47 1227 Long Cart Part No 04.140.01.0.00 , Belt Guard Cart Part No 04.141.01.0.00 , Spacer (Bar) Cart Part No 04.141.03.0.00 , Breather: Box Type Cart Part No 04.157.01.0.00 , Crank Pulley: Narrow 2Gr Cart Part No 04.195.01.0.00 , Crank Pulleyfor Mud Slinger Cart Part No 04.195.05.0.00 , Bracket: V Belt Switch Cart Part No 04.196.02.0.00 , Pulley: Fan 98Pcd Spz 1Gr Cart Part No 04.197.01.0.00 , Alternator Pulley Cart Part No 04.198.01.0.00 , Spacer For B Tension Lever Cart Part No 04.198.04.0.00 , Hose: Air Cleaner Cart Part No 04.203.08.0.00 , Hose For Air Cleaner Cart Part No 04.203.09.0.Pr , Air Inlet Manifold Cart Part No 04.214.01.0.00 , Wet Pm Kit (W/O Oil) For 04.2421, 04.2445 - Ha494 Cart Part No 04.242.1.0.Sp , Overhaul Kit Ha494 Bsii Indl Appl Cart Part No 04.246.30.0.00 , V Belt Ax51 Raw Cog Lp1341 Cart Part No 04.249.01.0.00 , V Belt Cogged Ax49 Raw Edge Lp1279 Cart Part No 04.249.02.0.00 , V Belt: Lp1131 Ax43 Raw Edge Cogged Cart Part No 04.250.01.0.00 , Hub For Fuel Pump Gear Cart Part No 04.266.01.0.00 , Filter Header: Lube Oil & Fuel Filter Cart Part No 04.268.01.0.00 , Adaptor For Pr.Gauge Conn. Cart Part No 04.268.02.0.00 , Spinon Lube Oil Filter Cart Part No 04.270.01.0.00 , Spin On Filter For Lubricating Oil Cart Part No 04.270.08.0.Pr , Intermediate Ring(1 Mm Thk.) Cart Part No 04.291.03.0.00 , Intermediate Ring: 1.3Mm Cart Part No 04.291.06.0.00 , Intermediate Ring 1.5Mm Thk Cart Part No 04.291.11.0.00 , Intermediate Ring(2.0 Mm Thick) Cart Part No 04.291.22.0.00 , Cylinder Head Assly Cart Part No 04.291.30.0.00 , Sealing Washer Cart Part No 04.292.04.0.00 , Nozzle Cart Part No 04.295.01.0.00 , Washer For Inj Cart Part No 04.295.03.0.00 , Injector Cart Part No 04.295.10.0.00 , Fuel Filter Cartridge Cart Part No 04.296.01.0.00 , Sealing Ring For Filter(Khd No 111 8693) Cart Part No 04.296.02.0.00 , Lube Oil Supply Hose Cart Part No 04.304.02.0.00 , Inlet Manifold Cart Part No 04.308.01.0.00 , Exhaust Silencer: Ha494tc Cart Part No 04.329.01.0.00 , Exhaust Silencer (S/F L&T) Cart Part No 04.329.04.0.00 , Exhaust Silencer Cart Part No 04.329.07.0.00 , Crank Pulley (238 Pcd,3 Gr,A Sect) Cart Part No 04.334.05.0.00 , Wet Pm Kit (W/O Oil ) For 4H.3422 - Ha494 Cart Part No 04.342.2.0.Sp , Pull Type Accelarator Lever (Indital) Cart Part No 04.355.01.0.00 , Set Of High Press Pipe Cart Part No 04.358.90.0.00 , Rubber Sealing Ring Cart Part No 04.362.03.0.00 , Assembly Air Guide Ring & Brush Cart Part No 04.362.10.0.00 , Hose: Air Cleaner Cart Part No 04.363.02.0.00 , Exhaust Silencer: Tractor Short Cart Part No 04.364.04.0.00 , Exhaust Silencer Cart Part No 04.364.08.0.00 , Hose: Air Cleaner Cart Part No 04.364.11.0.00 , Sub Assly Flex Exh Pipe: 2.5Idx550l Cart Part No 04.364.20.0.00 , Flexible Pipe Sub Assly Cart Part No 04.364.40.0.00 , Alternator: 12V 55A Cart Part No 04.367.01.0.00 , Lube Oil Sump: Side Drain Cart Part No 04.375.01.0.00 , Adaptor: Lube Filter Ha2 Cart Part No 04.378.05.0.00 , Hose: Air Cleaner S/F 24 V Alt Cart Part No 04.387.02.0.00 , Main Element Forair Cleaner Cart Part No 04.403.11.0.00 , Air Cleaner Assembly Cart Part No 04.403.20.0.Pr , Fuel Pump Ha494 Non Cmvr Variable Speed Cart Part No 04.416.40.0.00 , Lube Oil Sump: Flat Face Cart Part No 04.417.30.0.00 , Lube Oil Sump Assly With Baffle Plate Cart Part No 04.417.31.0.Pr , Lube Oil Sump: Flat Face Cart Part No 04.417.50.0.00 , Fip Assly 9 5 Dia Cart Part No 04.422.20.0.00 , Suction Tube Assly: Press Sump Cart Part No 04.444.20.0.00 , Dipstick Assly: Press Sump 210-170X25-38 Cart Part No 04.445.10.0.00 , Wiring Harness With Alternator Cart Part No 04.450.20.0.00 , Suction Tube Cart Part No 04.451.20.0.00 , Drain Pipe For Lube Oil Sump Cart Part No 04.452.01.0.00 , U-Clamp For Sump Drain Pipe Cart Part No 04.452.03.0.00 , Adaptor For Sump Drain Cart Part No 04.452.06.0.00 , V Belt Cogged Spz-Lp1280 98 Pcd Cart Part No 04.465.01.0.00 , Belt Cart Part No 04.465.02.0.Pr , V Belt ( Spzx 1280L) Blower Fan Pulley Cart Part No 04.465.03.0.Pr , Banjo Bolt Cart Part No 04.474.05.0.00 , Rubber Hose: Air Inlet Cart Part No 04.475.01.0.00 , Actuator Adc225 Gs 12V With Lever Cart Part No 04.493.01.0.00 , Spacer For Bracket Cart Part No 04.499.01.0.00 , Spacer For Alternator Mtg Bracket Cart Part No 04.499.04.0.00 , Bracket For Cable Type And Low Idle Speed Adjustment Cart Part No 04.508.01.0.Pr , Fuel Pipe: Tank To Feed Pump 1700Mm Cart Part No 04.513.01.0.00 , Dipstick Assly Cart Part No 04.529.40.0.00 , Fuel Level Mech Gauge 160Mm Cart Part No 04.536.02.0.00 , Fuel Pipe Filter To Feed Pump Cart Part No 04.536.03.0.00 , Fuel Pipe Pre-Filter To Tank Unit Cart Part No 04.536.04.0.00 , Fuel Pipe (Inlet) M14 X 1.5 Banjo (Both Sides) Length 950Mm Cart Part No 04.536.11.0.00 , Fuel Pipe From Tank To Fuel Filter Cart Part No 04.536.21.0.Pr , Fuel Pipe From Fuel Filter To Tank Cart Part No 04.536.23.0.Pr , Fuel Pipe From Pre Filter To Fuel Transfer Pump Cart Part No 04.536.26.0.Pr , Fuel Pipe From Pre Filter To Fuel Junction Box Cart Part No 04.536.27.0.Pr , Fuel Pipe From Fuel Transfer Pump To Feed Pump Cart Part No 04.536.29.0.Pr , Wiring Harness: Engine To Control Panel Cart Part No 04.540.20.0.00 , Air Inlet Manifold Cart Part No 04.564.01.0.00 , Adaptor For Air Inlet Manifold Cart Part No 04.564.02.0.00 , Exhaust Manifold Finish With External Egr Arrengment For Ha4t Cmvr Iii Cart Part No 04.566.02.0.00 , Joint: Ejr Pipe: Ha Bsiii Cart Part No 04.566.04.0.00 , Turbocharger Cart Part No 04.568.10.0.00 , Hose: Lube Oil Drain Turbo Cart Part No 04.574.04.0.00 , Adaptor For Lube Oil Pipe On Cranckcase Cart Part No 04.574.06.0.00 , Clip For Lube Oil Inlet Pipe Cart Part No 04.574.07.0.00 , Bracket For Clip Mounting Cart Part No 04.574.08.0.00 , Rubber Sleeve For Lube Oil Pipe Cart Part No 04.574.09.0.00 , Exhaust Diffuser Cart Part No 04.575.01.0.00 , Joint: Exhaust Diffuser Cart Part No 04.575.04.0.00 , Spacer For Tension Lever Cart Part No 04.576.02.0.00 , Primary Air Cleaner Element Cart Part No 04.586.03.0.00 , Air Cleaner Safety Element Cart Part No 04.586.04.0.00 , Air Cleaner Assly+ Strainer Cart Part No 04.586.30.0.00 , Air Cleaner Assly: Dry Type Cart Part No 04.587.10.0.00 , Hose: Air Cleaner Cart Part No 04.588.02.0.00 , Restriction Indicator Cart Part No 04.588.05.0.00 , Hot Air Ducting Sf Ha494 Tc Engine With Kkk Turbocharger Cart Part No 04.592.10.0.00 , Sub Assembly Of Cam Shaft (Cpcb) With Chilled C.I. Cam Shaft Cart Part No 04.594.20.0.00 , Fuel Pump Assembly Cart Part No 04.595.10.0.00 , Injector Cart Part No 04.596.03.0.00 , Exhaust Silencer Cart Part No 04.599.01.0.00 , Rain Cap: Black Cart Part No 04.599.02.0.00 , Box Type Breather Cart Part No 04.600.01.0.00 , Wet Pm Kit (W/O Oil) For 4H.6007 Cart Part No 04.600.7.0.Sp , Adaptor For Exhaust Silencer Cart Part No 04.612.01.0.00 , Fuel Pipe (S/F041221)1400 L, 95 Id, 14 Banjo Cart Part No 04.613.01.0.00 , Expansion Bellow Cart Part No 04.625.02.0.00 , Silencer Cart Part No 04.625.10.0.00 , Hot Air Ducting Assly Cart Part No 04.666.10.0.00 , V Belt Cogged-Avx10 1265L Blower Pulley Cart Part No 04.668.01.0.00 , V Belt Coggedspax1260lblower Pulley Cart Part No 04.668.02.0.Pr , V Belt Cogged Avx 10-1136 For Alternator Pulley Cart Part No 04.669.01.0.00 , Assembly Air Guide Ring Cart Part No 04.670.10.0.00 , Starter: 12V 2.7Kw Cart Part No 04.677.01.0.00 , Valve Seat Insert: Exhaust Cart Part No 04.684.02.0.00 , Cylinder Head Assemblycomplete Cart Part No 04.684.70.0.00 , Con Rod Assly: Wo Le Brg Cart Part No 04.685.20.0.00 , Pulley: Fan 79Pcd Spz 1Gr Cart Part No 04.690.01.0.00 , Con Rod Assly: Mas Bal Wo Le Brg Cart Part No 04.691.20.0.00 , Connecting Rod Bolt Cart Part No 04.692.03.0.00 , Connecting Rod Assly Cart Part No 04.692.10.0.00 , Belt: Spzx Section Alt24v Lp1180 Cart Part No 04.708.01.0.00 , Adaptor For Rotary Fuel Pump Mounting Cart Part No 04.725.02.0.00 , Hub For Fip Gear Cart Part No 04.725.04.0.00 , Exhaust Manifoldfinish Cart Part No 04.734.03.0.00 , Turbocharger Cart Part No 04.735.02.0.00 , Joint: Turbo Inlet Cart Part No 04.750.02.0.00 , Joint: Lube Oil Outlet Flange Cart Part No 04.751.02.0.00 , Hose: Lube Oil Drain Ha494 Bs3 Cart Part No 04.751.03.0.00 , Lube Oil Drain Pipe: Front Cover Ha4 Cart Part No 04.751.05.0.00 , Turbo Oil Inlet Pipe Cart Part No 04.751.120.0.00 , Lube Oil Inlet Pipe Assly Cart Part No 04.751.60.0.00 , Cac Outlet Pipe To Inlet Manifold Cart Part No 04.752.01.0.00 , Hose (Cac Out) Cart Part No 04.752.03.0.00 , Hose (Cac-In) Cart Part No 04.752.08.0.00 , Intercooler Assembly For Ha4 Tcicpcb Ii Cart Part No 04.752.10.0.00 , Bracket For Fuel Filter Cart Part No 04.755.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 04.755.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 04.755.03.0.00 , Combine Leak Off Pipe Injector To Fuel Filter Cart Part No 04.755.06.0.00 , Fuel Pipefrom Combined Leakoff To Fuel Tank Cart Part No 04.755.07.0.00 , Comb Leak Off Pipe: Ha Bsiii Cart Part No 04.755.10.0.00 , Fuel Pipefeed Pump To Filter Cart Part No 04.755.16.0.Pr , Fuel Pipefuel Filter To Fuel Pump Cart Part No 04.755.18.0.Pr , Leakoff Pipe For Fuel Pump To Junctionbox Cart Part No 04.755.33.0.Pr , Primary Filter Element Cart Part No 04.760.01.0.00 , Safety Filter Element Cart Part No 04.760.02.0.00 , Air Cleaner Assly: Dry 8M3 Cart Part No 04.760.10.0.00 , Fuel Level Gauge Mech: Dial 140 Mm Cart Part No 04.768.03.0.00 , Wiring Harness S/ F Ha4 With Pump Mounted Stop Solenoid Cart Part No 04.773.10.0.00 , High Pressure Pipe Assly Cart Part No 04.785.90.0.00 , Engine Wiring Harness Assembly Cart Part No 04.786.60.0.00 , Engine Wiring Harness With Governor And Cold Start Cart Part No 04.786.81.0.00 , Exciter Rotor Cart Part No 04.805.15.0.00 , Terminal Block: Kg35st-125St Cart Part No 04.805.21.0.00 , Terminal Block For 225 Frame (Ta3l10) Cart Part No 04.805.38.0.00 , Terminal Block For 280 Frame (Ta3t10) Cart Part No 04.805.39.0.00 , Rotating Rectifier Assly For Kg200/225/280 Frame Kg35 To Kg200 Kva Altrnators Cart Part No 04.805.49.0.00 , Fuel Pump Cart Part No 04.813.10.0.00 , Nozzle Leak Off Pipe Cart Part No 04.815.20.0.00 , Assembly Instrument Panel With Meters Altr Hr Cart Part No 04.859.40.0.00 , 4 Pole Mcb 63 Amp Cart Part No 04.861.01.0.00 , Ems 18 Comunication Module For Rs 485 Out Put Cart Part No 04.931.11.0.00 , 1 Relay+Board, 12Vdc, 5A, 2C/O Cart Part No 04.942.07.0.00 , 1 Relay+Board, 24Vdc, 5A Cart Part No 04.942.08.0.00 , 1 Relay Board230vac5a Cart Part No 04.942.09.0.00 , Crankshaft Assly Integral Cart Part No 04.956.40.0.00 , Fip: Ha494 Tcicpcb-Ii Cart Part No 04.978.01.0.00 , Standyne Rotary Fip For Ha 494 Tci G1 Cart Part No 04.978.05.0.00 , Wet Pm Kit (W/O Oil) For 4.1153 - Ha494 Cart Part No 04.999.05.0.Sp , Wet Pm Kit (W/O Oil) For 04.8908 - Ha494tci G1 Cart Part No 04.999.06.0.Sp , Ha494 Pg Service Kit B Check Cart Part No 04.999.35.0.00 , Ha494 Pg Service Kit With Air Filter -C Chk Cart Part No 04.999.36.0.00 , Ha494 Cpcb Ii Service Kit - B Check Cart Part No 04.999.37.0.00 , Ha494 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 04.999.38.0.00 , Wet Pm Kit (W/O Oil) For 04.2145, 04.2121... Ha-494 Cart Part No 04.999.40.0.Sp , Wet Pm Kit (W/O Oil) For 4.8901,4.8904,3.8805- Ha494tci G1 Cart Part No 04.999.52.0.Sp , Wet Pm Kit (W/O Oil) For 04.2015 - Ha494 Cpcb Vertical Solonoid Cart Part No 04.999.56.0.Sp , Service Kit: 500Hrs Ha494 Bsiii Indl Transit Mixer Cart Part No 04.999.80.0.00 , Wet Pm Kit (W/O Oil ) For 04.9102 Cart Part No 04.999.81.0.Sp , Serv Kit A: 500 Hrs Ha494 Bsiii Indl Concrete Pump Cart Part No 04.999.85.0.00 , Wet Pm Kit (W/O Oil) For 04.8901 - Ha494 Cart Part No 04.999.86.0.Sp , Service Kit B 500 Hrs: Ha494 Bsiii Indl Concrete Pump Cart Part No 04.999.90.0.00 , Lub Oil Supply Hosec Case To Fuel Pump Cart Part No 04.M001.05.0.00 , Ccase Assly W/O Bearing Cart Part No 06.001.50.0.00 , Crankshaft Assembly Cart Part No 06.004.40.0.00 , Camshaft & Gear Assly Cart Part No 06.005.10.0.00 , Camshaft And Gear Assly Cmvr Ii Cart Part No 06.005.20.0.00 , Cam Shaft & Gear Assembly Cart Part No 06.005.50.0.00 , Comb Leak Off Pipe: Ha694 Cart Part No 06.006.01.0.00 , Union Screw Cart Part No 06.008.02.0.00 , Double Cone Ring Cart Part No 06.008.03.0.00 , Clamping Strap Cart Part No 06.008.04.0.00 , Sub Assembly Of Suction Tube Cart Part No 06.008.20.0.00 , Counter Sunk Socket Head Screw. Cart Part No 06.010.01.0.00 , Lub Oil Pump Assly Cart Part No 06.010.130.0.00 , Lube Oil Pump Assly Cart Part No 06.010.60.0.00 , Joint: Air Inlet Manifold To Cac Pipe Cart Part No 06.011.07.0.00 , Joint: Cac Pipe Cart Part No 06.011.08.0.00 , Cac-In Pipe ( Cac Side) Cart Part No 06.011.18.0.00 , Crank Pulley Assly Cart Part No 06.017.10.0.00 , Assly Of Crank Pulley ( Modified For Banded Belt) Cart Part No 06.017.40.0.00 , Lower Cowling Sub Assly Cart Part No 06.019.10.0.00 , Lower Cowlings Fmodified Cooler 06 1631 Cart Part No 06.019.40.0.00 , Lube Oil Cooler Cart Part No 06.020.01.0.00 , Sealing Ring Lube Oil Cooler Cart Part No 06.020.02.0.00 , Lube Oil Cooler -Ha6 Cart Part No 06.020.07.0.00 , Sealing Ring Cart Part No 06.020.08.0.Pr , Front Cowling Cart Part No 06.021.01.0.00 , Front Cowling Cart Part No 06.021.04.0.00 , Top Air Baffle Cart Part No 06.022.01.0.00 , Exhaust Air Baffle Cart Part No 06.024.10.0.00 , Ball Bearing(25X52x15) Cart Part No 06.025.13.0.00 , Fan Pulley (119 Pcd, A Section, 2 Grooves- Modified For Cart Part No 06.025.14.0.00 , Assly Of Cooling Blower Cart Part No 06.025.40.0.00 , Sub Assly Leak Off Pipe Cart Part No 06.027.20.0.00 , Air Inlet Manifold G.E.Opening Cart Part No 06.028.01.0.00 , Air Inlet Manifold Cart Part No 06.028.05.0.00 , Air Inlet Manifold Cart Part No 06.028.06.0.00 , Upper Cowling Cart Part No 06.029.10.0.00 , Banded Wrapped Belt 2Ja1310lp (1310 Mm Effective Pitch) Cart Part No 06.031.01.0.00 , Banded Cogged Belt: Lp1310 2Jax50 Cart Part No 06.031.04.0.00 , Banded Wrapped Belt 2Ja 51 -1328Mm Pitch Length Cart Part No 06.032.01.0.00 , Banded Wrapped Belt: 2Ja 52 1354 Long Cart Part No 06.032.02.0.00 , Belt :2Jax51 Lp -1326 Banded Cogged Cart Part No 06.032.03.0.00 , Belt: Lp1352 Banded Cogged 2Jax52 Cart Part No 06.032.04.0.00 , Starter Motor 12V 3Kw Cart Part No 06.033.01.0.00 , Starter 12V Cart Part No 06.034.02.0.00 , Starter 24V Cart Part No 06.034.06.0.00 , Hose: Inlet Manifold Cart Part No 06.037.01.0.00 , Hose: Inlet Manifold Cart Part No 06.037.03.0.00 , Lube Oil Filter Element Cart Part No 06.040.01.0.00 , Lube Oil Filter Assly Cart Part No 06.040.10.0.00 , Special Nut: Brass Cart Part No 06.046.02.0.00 , Exhaust Mfold Ge Top Open Cart Part No 06.046.10.0.00 , B.T. Unit Sub Assly Cart Part No 06.047.90.0.00 , Belt Tension Unit With Actuator Cart Part No 06.047.91.0.00 , Air Cleaner Oil Bath Cart Part No 06.048.01.0.00 , Pre Cleaner Cart Part No 06.048.02.0.00 , Clamp For Pre Cleaner Cart Part No 06.048.03.0.00 , Air Cleaner Clamp Cart Part No 06.048.05.0.00 , Air Cleaner Assly Cart Part No 06.048.10.0.00 , Bracket For Air Cleaner Cart Part No 06.049.01.0.00 , Hose: Air Cleaner Cart Part No 06.049.02.0.00 , Set Of Joints Cart Part No 06.050.10.0.Sp , Set Of O Rings: Ha694 Cart Part No 06.051.10.0.00 , V Belt : A 52 1354 Long Cart Part No 06.052.01.0.00 , Set Of High Pressure Pipe Cart Part No 06.055.90.0.00 , Rain Cap Cart Part No 06.065.20.0.00 , Sub Assembly Of Rain Cap With Modified Bend Cart Part No 06.065.30.0.00 , Sub Assembly Of Exhaust Cart Part No 06.066.20.0.00 , Exhaust Mfold: 4Cyl Cart Part No 06.069.01.0.00 , Exhaust Mfold: 2Cyl Cart Part No 06.069.02.0.00 , Compression Ring Cart Part No 06.069.03.0.00 , Compression Ring Cart Part No 06.069.04.0.00 , Joint (For Exh. Silencer) Cart Part No 06.069.07.0.00 , Exhaust Manifold4 Clysub Assly With Adaptor For Exhaust Silencer Cart Part No 06.069.20.0.00 , Spacer (Bar) For Actuator Cart Part No 06.072.03.0.00 , Stopping Bar Cart Part No 06.072.20.0.00 , Crankshaft Gear: Knurled Cart Part No 06.073.01.0.00 , Crankshaft Assly With Cr Gear Cart Part No 06.073.50.0.00 , Spacer Plate Cart Part No 06.074.14.0.00 , Gasket: 1.5Mm Thk Cart Part No 06.074.15.0.00 , Washer -Sheet Metal L.O.Sump Cart Part No 06.074.16.0.00 , Lube Oil Sump: Flat Face Cart Part No 06.074.30.0.00 , O Ring2 6X45 21511 Cart Part No 06.076.04.0.00 , Adaptor: Dipstick Assly Cart Part No 06.077.05.0.00 , Stop Solenoid 12V 20Mm Foot Mtg Cart Part No 06.081.01.0.00 , Mounting Plate (Lube Oil Filter Side) Cart Part No 06.082.02.0.00 , Mounting Plate (Starter Side) Cart Part No 06.082.03.0.00 , Ball Bearing(25X62x17) 6305Z,C3 Cart Part No 06.085.05.0.00 , Fan Pulley (90 Pcd A Section, 2 Grooves) Cart Part No 06.085.12.0.00 , Assly Cooling Blower Hyd Oil Cooler Cart Part No 06.085.40.0.00 , Fan Body Stator & Impell Sub Assly Cart Part No 06.085.60.0.00 , Fan Body: With Rubber Cart Part No 06.085.70.0.00 , Sub Assembly Of Fan Body, Stator And Impeller (Angular Bearing) Cart Part No 06.085.80.0.00 , Mounting Strap Cart Part No 06.086.03.0.00 , Vacuator Valve Cart Part No 06.086.04.0.00 , Temp Switch Cart Part No 06.087.02.0.00 , Ammeter (60-0-60 Amps) Cart Part No 06.087.06.0.00 , U Clamp Cart Part No 06.089.02.0.00 , Clamping Plate Cart Part No 06.089.03.0.00 , Clamping Plate ( S/F - 04.329.04.0.00 Silencer) Cart Part No 06.089.04.0.00 , U Clamp ( S/F - 04.329.04.0.00 Silencer) Cart Part No 06.089.05.0.00 , Clamping Plate Cart Part No 06.089.06.0.00 , U Clamp Cart Part No 06.089.07.0.00 , End Cover For Bell Housing Cart Part No 06.091.01.0.00 , Suction Tube Cart Part No 06.092.10.0.00 , Hub On Crank Pulley Cart Part No 06.097.01.0.00 , V Belt: A51 1328 Long Cart Part No 06.098.01.0.00 , Cowling Assly Cart Part No 06.101.10.0.00 , Spark Arrestor Cart Part No 06.105.01.0.00 , Solenoid Valve 12V Cart Part No 06.107.02.0.00 , Adaptor On Fuel Pump (Bar)(M12 X 15) Cart Part No 06.107.11.0.00 , Adaptor On Fuel Pump M14x1 5 Cart Part No 06.107.14.0.00 , Flame Heater 12V Cart Part No 06.107.16.0.00 , Fuel Pipe Solenoid To Heater Cart Part No 06.107.20.0.00 , Fuel Pipe Fip To Solenoid Cart Part No 06.107.30.0.00 , Fuel Pipe Assly Fuel Pump To Soln Sr2000 Cart Part No 06.107.40.0.00 , Flame Heater 24V System Cart Part No 06.108.01.0.00 , Solenoid Valve 24V Cart Part No 06.108.02.0.00 , Bimetal Switch 24 V Cart Part No 06.108.03.0.00 , Spacer 9X20x9thick Cart Part No 06.158.01.0.00 , Spacer(9X18x25thick) Cart Part No 06.158.02.0.00 , Fuse Holder With 100 Amp Fuse Cart Part No 06.1684.06.0.00 , Fip For Ha694 Tci Engine Cpcb Ii Cart Part No 06.1724.01.0.00 , Standyne Rotary Fip For Ha 694 Tci G1 Cart Part No 06.1724.22.0.00 , Spacer For Fuel Filter Cart Part No 06.211.01.0.00 , Plastic Tube: 500Mm Bar Cart Part No 06.216.01.0.00 , Plastic Tube For Breather Pipe 1200 Mm Cart Part No 06.216.94.0.Pr , One Pipe Exh Manifold F Cart Part No 06.219.01.0.00 , Two Pipe Exh Manifold F Cart Part No 06.219.02.0.00 , Sealing Ring Cart Part No 06.219.03.0.00 , Rubber Hose For Drain Pipes Cart Part No 06.224.11.0.00 , Assembly Of Lub Oil Inlet Pipe Cart Part No 06.224.30.0.00 , Nut (Special) Cart Part No 06.225.03.0.00 , Pre Cleaner Assly Cart Part No 06.229.20.0.00 , Pre Cleaner Assembly Cart Part No 06.229.60.0.00 , Silicon Coated Fiber Glass Clothsize After Forming 15X 7X 10With Fittings Fo Cart Part No 06.245.22.0.00 , Primary Filter Element Cart Part No 06.246.02.0.00 , Safety Air Filter Elemnt Cart Part No 06.246.03.0.00 , Dipstick Assly Cart Part No 06.248.10.0.00 , Air Inlet Manifold Cart Part No 06.254.01.0.00 , Adaptor: Bet Exh Mold & Turbo Cart Part No 06.255.01.0.00 , Bracket For Turbocharger Mounting Cart Part No 06.256.01.0.00 , Joint: Turbo Exh Outlet Cart Part No 06.256.03.0.00 , Hose: Air Cleaner Cart Part No 06.260.02.0.00 , Hose: Air Inlet Manifold Cart Part No 06.260.03.0.00 , Bracket For Alternator (24 V Gac 5R) Cart Part No 06.265.04.0.00 , Dowel Bolt For Alternator Cart Part No 06.265.05.0.00 , Tension Lever Cart Part No 06.265.06.0.00 , Exhaust Silencer: Ha694 Cart Part No 06.266.01.0.00 , Intermediate Ring: 1.1Mm Cart Part No 06.292.01.0.00 , Rain Cap Assly Cart Part No 06.309.02.0.00 , Clamp For Exhaust Pipe Cart Part No 06.309.04.0.00 , Bracket: Alternator Cart Part No 06.326.03.0.00 , Bush Cart Part No 06.326.09.0.00 , Tension Lever Cart Part No 06.326.13.0.00 , Fuel Pipe Feed Pump -Fuel Filter Cart Part No 06.333.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 06.333.02.0.00 , Bracket Cart Part No 06.333.03.0.00 , Bracket For Fuel Filter Cart Part No 06.333.07.0.00 , V Belt: Ax50 Lp1303 Raw Edge Cogged Cart Part No 06.337.01.0.00 , V Belt: Lp1254 Ax48 Raw Edge Cogged Cart Part No 06.338.01.0.00 , Rubber Hose: Air Cleaner 100X100x80l Cart Part No 06.347.03.0.00 , V Belt: Lp 1362 Ax52 Raw Edge Cogged Cart Part No 06.353.01.0.00 , V Belt Ax46 Raw Edge Cogged Cart Part No 06.354.01.0.00 , Hydraulic Pump Dowty Ip 3052 Cart Part No 06.357.02.0.00 , Adaptor On Unloader Valve Cart Part No 06.358.12.0.00 , Assly.Of Crank Pulley And Damper Cart Part No 06.363.10.0.00 , T Bolt Clamp Klipco Tb72/Jupitor ( 79 To 87 Dia) Cart Part No 06.376.03.0.00 , T Bolt Clamp Cart Part No 06.376.04.0.00 , Tbolt Clamp Klipco Tb64 Jupitor 50 To 64 Dia Cart Part No 06.376.05.0.00 , Tbolt Clamp (Range From Dia 116 To 123) Cart Part No 06.376.08.0.00 , Clamp For Battery Cart Part No 06.387.05.0.00 , Digital Temperature Switch Guage Cart Part No 06.387.41.0.00 , Sub Assly Of Cam Shaft Hyd Pump Cart Part No 06.389.10.0.00 , Inlet Manifold Cart Part No 06.398.01.0.00 , Hose: Air Cleaner Cart Part No 06.403.01.0.00 , Exhaust Diffuser (Upward Open) Cart Part No 06.420.01.0.00 , Set Of Joints Cart Part No 06.429.10.0.Sp , Spinon Lube Oil Filter Cart Part No 06.436.01.0.00 , Fuel Pump Assly Cart Part No 06.441.10.0.00 , Spacer 20 X 9 X 8.5 Th. Cart Part No 06.442.02.0.00 , Bracket For Air Cleaner Cart Part No 06.465.01.0.00 , Hose: Air Cleaner Cart Part No 06.465.03.0.00 , Flange For Exhaust Diffuser Down Open Cart Part No 06.468.02.0.00 , Joint: Exh Diffuser Cart Part No 06.468.03.0.00 , Joint: Exhaust Cart Part No 06.468.04.0.00 , Hot Air Ducting: Upward Opening Cart Part No 06.469.10.0.00 , Rubber Sealing Ring Cart Part No 06.471.03.0.00 , Assembly Air Guide Ring & Brush Cart Part No 06.471.10.0.00 , Set Of High Press Pipe: Dha694 Cart Part No 06.473.90.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 06.474.03.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 06.474.04.0.00 , Fuel Filter Element Assly Cart Part No 06.474.05.0.00 , Adaptor For Air Bleed Filter Cart Part No 06.474.19.0.00 , Fuel Pipe From Combined Leak Off To Tank Cart Part No 06.474.24.0.00 , Combined Leak Off Pipefrom Nozzle Leak Off To Filter Leak Off Cart Part No 06.474.25.0.00 , Fuel Filter Bsiii Ha494 Ha694 Cart Part No 06.474.50.0.00 , Front Cover Cart Part No 06.482.01.0.00 , Adaptor On Crank Pulley Cart Part No 06.484.06.0.00 , Fan: 390Mm Od 11 Blades Cart Part No 06.484.11.0.00 , Adaptor Forfan Cart Part No 06.484.12.0.00 , Exhaust Diffuser Upward Open Cart Part No 06.488.01.0.00 , Belt: Ax47, Lp1227 Raw Edge Cogged Cart Part No 06.491.01.0.00 , Fuel Pipe (Return) M12 X 15 Male Plug X M14 X 15 Banjo (900 Cart Part No 06.5001.21.0.00 , Fip Assly 9 5 Dia Cart Part No 06.527.30.0.00 , Fip Assly: 9.5 Dia Cart Part No 06.529.20.0.00 , Belt : Lp-1150 Ax44 Raw Edge Cogged Cart Part No 06.531.01.0.00 , Pre Cleaner Assly Cart Part No 06.550.20.0.00 , Pre Cleaner Cart Part No 06.550.50.0.00 , Suction Tube Cart Part No 06.555.20.0.00 , Assembly Iinstument Panel With Meters(Altr,Hr) Cart Part No 06.573.50.0.00 , Wiring Harness Ha694 P.G.Engine With Alt Cart Part No 06.574.20.0.00 , Adapter For Exhaust Silencer Cart Part No 06.586.02.0.00 , Left Hand Lock With Catcher (Upto 82.5 Kva) Cart Part No 06.597.94.0.00 , Lh Lock With Catcher 100-600 Kv Cart Part No 06.598.03.0.00 , Rh Lock With Catcher 100-600 Kva Cart Part No 06.598.04.0.00 , Rh Lock With Catcher To 82.5 Kva Cart Part No 06.598.05.0.00 , Expansion Bellow Assly 3 Cart Part No 06.602.10.0.00 , Hose Tail: Fuel Leak Off Conn Cart Part No 06.610.02.0.00 , Fuel Pipe: 9.5 I.D.X4000 L Cart Part No 06.610.03.0.00 , Adaptor For 2R1040 For Water Connection Cart Part No 06.610.08.0.00 , Hose Tail Connection S/F M14 Cart Part No 06.610.10.0.00 , Sleeve For Exhaust Silencer Cart Part No 06.628.02.0.00 , Valve Guide Cart Part No 06.631.01.0.00 , Valve Stem Seal Cart Part No 06.631.02.0.00 , Fuel Pipe Tank To Feed Pump Cart Part No 06.635.14.0.00 , Fuel Pipe 4Mtr And Clamps Cart Part No 06.654.10.0.00 , V Belt: Lp1176 Ax45 Raw Edge Cogged Cart Part No 06.672.01.0.00 , Lube Oil Sump Cart Part No 06.677.10.0.00 , Adaptor For Autotimer Cart Part No 06.699.01.0.00 , Fuel Pump Gear Cart Part No 06.699.02.0.00 , Leak Off Pipe Assly Cart Part No 06.711.10.0.00 , Rpm Indicator: Built In Regulator Cart Part No 06.712.01.0.00 , T- Bolt Clamp ( 90 Mm) Cart Part No 06.713.03.0.00 , Tbolt Clamp104 Mm Cart Part No 06.713.04.0.00 , Fuel Pipe (Return) M12x15 Male Plug X M14x15 Banjo Cart Part No 06.718.02.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 06.718.04.0.00 , Fuel Pipe Pre-Filter To Feed Pump Cart Part No 06.718.05.0.00 , Fuel Pipe Inlet: M14x1.5 Banjo Both Side 650Mm Cart Part No 06.718.11.0.00 , Cam Shaft & Gear Assembly Cart Part No 06.738.10.0.00 , Right Angle Adaptor For Sc160 Comp Cart Part No 06.751.01.0.00 , Banjo Bolt (M22x1.5) Cart Part No 06.751.06.0.00 , Banjo Coupling Cart Part No 06.751.40.0.00 , Primary Filter Element Cart Part No 06.757.03.0.00 , Safety Air Filter Elemnt Cart Part No 06.757.04.0.00 , Air Cleaner Assly + Strap Cart Part No 06.757.30.0.00 , Mounting Strap Assembly (For Air Cleaner) Cart Part No 06.757.40.0.00 , Air Cleaner Assly+ Strap Cart Part No 06.761.20.0.00 , Adaptor: Turbocharger Mounting Cart Part No 06.764.02.0.00 , Joint: Turbocharger Cart Part No 06.764.03.0.00 , Bracket For Turbocharger Mounting Cart Part No 06.765.01.0.00 , Swivel Adaptor Cart Part No 06.765.02.0.00 , Turbocharger Cart Part No 06.766.10.0.00 , Turbocharger Cart Part No 06.766.20.0.00 , Assembly Of Lube Oil Inlet Pipe Cart Part No 06.767.10.0.00 , Sub Assembly Of Lube Oil Drain Pipe (Long) Cart Part No 06.767.20.0.00 , Subassembly Of Lube Oil Drain Pipe Cart Part No 06.767.30.0.00 , Spacer For Footgear End Cart Part No 06.769.04.0.00 , Hose: Air Cleaner Cart Part No 06.770.01.0.00 , Plate For Air Cleaner Mounting Cart Part No 06.770.02.0.00 , Hose: Air Cleaner Cart Part No 06.770.03.0.00 , Dipstick Assembly Cart Part No 06.776.10.0.00 , Dipstick Assembly Cart Part No 06.776.30.0.00 , Expansion Bellow Cart Part No 06.786.20.0.00 , Stopping Bar For Stop Solenoid Cart Part No 06.791.01.0.00 , Stop Solenoid 24V Sing Coil 75 Dia Cart Part No 06.793.01.0.00 , Nozzle Leak Off Pipe Cart Part No 06.819.20.0.00 , Rubber Hose (82 X 82 X 90 Deg) For Air Cleaner Cart Part No 06.820.01.0.00 , Exhaust Bend ( 76.2 X 70.5 X 90 Deg ) Cart Part No 06.821.01.0.00 , Expansion Below (3.0) Cart Part No 06.821.04.0.00 , Assembly Air Guide Ringmount Cart Part No 06.866.10.0.00 , Electrical Dwgfor Anti Condensation Heater Control Panel230v Ac1 Ph 50Hz Cart Part No 06.875.25.0.Pr , Rubber Hose ( Turbo Air Outlet ) Cart Part No 06.886.04.0.00 , One Pipe Exhaust Manifold Cart Part No 06.887.01.0.00 , Joint: Egr Pipe-Ha6 Bsiii Cart Part No 06.887.07.0.00 , Joint For Egr Pipe 50 Crs Exhmanifold End Cart Part No 06.887.09.0.00 , Crankcasew O Bearing For Bs Iii Va Ve Cart Part No 06.890.40.0.00 , Adaptor On Crank Case Cart Part No 06.891.05.0.00 , Hose ( L.O Turbo Drain ) --S/F L.H.D --Sa Cart Part No 06.891.07.0.00 , Adaptor (On Crankcase For Torbo Inlet Pipe) Cart Part No 06.891.13.0.00 , Assembly Of Lube Oil Inlet Pipe Cart Part No 06.891.40.0.00 , Wiring Harnessfor Esu Unitside Mounted Control Panel Cart Part No 06.915.20.0.00 , Indicating Lamp Green- 240V Cart Part No 06.953.18.0.00 , Terminal Type Cts 2 5Un Cart Part No 06.953.38.0.00 , Wiring Harness With Pump Mounted Stop Solenoid Cart Part No 06.971.10.0.00 , Mounting Ring For Turbo Cart Part No 06.972.01.0.00 , Dog Bone For Kkk27 Turbo Cart Part No 06.972.02.0.00 , B.T. Unit Assly & Actuator Cart Part No 06.973.40.0.00 , Sub Assembly Of B.T Unit (Modified For Banded Belt) Cart Part No 06.973.60.0.00 , B.T Unit Assembly (Modified) With Actuator Plate Cart Part No 06.973.70.0.00 , B.T. Unit Sub Assly Modified Cart Part No 06.973.90.0.00 , Assembly Of Belt Tension Unit Cart Part No 06.973.95.0.00 , Relay 12 Vdc 100 Amp Capacitytype Bgr 215 Cart Part No 06.980.07.0.00 , Engine Wiring Harness For Ha694 S F 934 Unit Cart Part No 06.998.10.0.00 , Wet Pm Kit (W/O Oil) For 06.8901...,06.8903... - Ha694tci G1 Cart Part No 06.999.12.0.Sp , Wet Pm Kit (W/O Oil) For 6.2145 - Ha694 ( 12V Cpcb ) Cart Part No 06.999.13.0.Sp , Ha694 Cpcb Ii Service Kit - B Check Cart Part No 06.999.35.0.00 , Ha696 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 06.999.36.0.00 , Wet Pm Kit (W/O Oil) For 06.2445 - Ha694 Cart Part No 06.999.68.0.Sp , Wet Pm Kit (W/O Oil) For 06.2401, 06.2402 - Ha694tc Cpcb Vertical Solonoid Cart Part No 06.999.69.0.Sp , Wet Pm Kit (W/O Oil) For 06.2421 - Ha 694 Cart Part No 06.999.90.0.Sp , 6A, 1 Pole, Mcb Cart Part No 06.M801.17.0.00 , Core Plug For Oil Gallery Cart Part No 08.001.18.0.00 , Valve Stem Seal Cart Part No 08.010.12.0.00 , Hard Washer For Balancer Shaft Cart Part No 08.013.05.0.00 , Joint: Feed Pump Cart Part No 08.021.02.0.00 , Fork For Injector Cart Part No 08.030.04.0.00 , Steel Ball Hard 1/4 Dia Cart Part No 10.004.11.0.00 , Woodruff Key Cart Part No 10.007.02.0.00 , Key: Flywheel Cart Part No 10.007.03.0.00 , Jt Cr Case Fwe M B Hsgsspl Ss Ko 1243 Cart Part No 10.008.07.0.00 , Nut (7/16 Bsf) Cart Part No 10.011.04.0.00 , Stud: 5/16 Bsf X 1-5/16 Lg Cart Part No 10.013.08.0.00 , Valve Tappet (Steel) Av1 Cart Part No 10.016.04.0.00 , Governor Spring(1500 & 1800 Rpm) Cart Part No 10.018.02.0.00 , Governor Wt Assly: 1500 Rpm Cart Part No 10.018.10.0.00 , Hard Washer (F) Cart Part No 10.020.03.0.00 , Joint: F-Bkt & Adapt-Pl Cart Part No 10.024.07.0.00 , Joint: Adapt-Pl & Ccase Cart Part No 10.024.11.0.00 , Joint: Fp Bkt & Ccase Cart Part No 10.025.08.0.00 , Lead Seal (5945010300) Cart Part No 10.027.02.0.00 , Jointt-0010 Cart Part No 10.027.11.0.00 , Joint-0015 Cart Part No 10.027.12.0.00 , Joint: 0.005 Al Cart Part No 10.027.29.0.00 , Joint: Fp Bracket & Shims Cart Part No 10.027.35.0.00 , Washer For Injector Cart Part No 10.029.07.0.00 , Oil Seal Cart Part No 10.030.05.0.00 , Lube Oil Filter Element Cart Part No 10.031.05.0.00 , Jt-Rcover Cart Part No 10.033.01.0.00 , Sealing Ring - Fuel Filter(7.5X63.3) Cart Part No 10.034.03.0.00 , Element Fuel Filter With Grommet Av1 Cart Part No 10.034.13.0.00 , Joint: Water Flange Cart Part No 10.043.02.0.00 , P K Drive Screw 1/8X3/8 (Rivet) Cart Part No 10.046.02.0.00 , Extension Shaft (7.625 Long) Cart Part No 10.062.01.0.00 , Strainer Holder Cart Part No 10.079.02.0.00 , V Belt A-33 Cart Part No 10.122.05.0.00 , Joint: Water Inlet Mfold Cart Part No 10.323.03.0.00 , Gear Pump-Av1,Sr,With Rel.Valve Cart Part No 10.366.40.0.00 , Overload Stopper Assly Cart Part No 10.710.10.0.00 , Flywheel Key Puller Cart Part No 10.950.12.0.00 , Locking Pinffor Intbrg Hsg Cart Part No 11.002.04.0.00 , Gear Cover Plate Cart Part No 11.006.02.0.00 , Jt Gear Cover Plate& Ccase Cart Part No 11.006.04.0.00 , Rack Adjscrew(Twin Fuel Pump Linkage) Cart Part No 11.013.22.0.00 , Set Screw Cart Part No 11.013.23.0.00 , Jt Gear Cover& Gr Cover Plate Cart Part No 11.014.04.0.00 , Inspection Cover (F) - Av2 Cart Part No 11.015.01.0.00 , Joint: Insp Cover Cart Part No 11.015.03.0.00 , Fuel Filter Element -Av2 Cart Part No 11.018.04.0.00 , Govn Push Rodf W E Cart Part No 11.037.03.0.00 , Assly Of Gov Push Rod Gear Endtwin Cart Part No 11.037.20.0.00 , Dowelf Cart Part No 11.169.05.0.00 , Fuel Filter Element Cart Part No 11.203.09.0.00 , Bracket For Fuel Filter(C.I.) Cart Part No 11.203.19.0.00 , Fuel Filter Assly Cart Part No 11.203.50.0.00 , Fuel Filter Assly(0.5 Lit)(Vave) Cart Part No 11.203.95.0.00 , L O Pipe Assly -Ccase-Fwe Brg Hsg Cart Part No 11.242.10.0.00 , Washer For Cylinder Head Nut Cart Part No 12.001.06.0.00 , O Ring: Push Rod Tube Viton Cart Part No 12.005.05.0.00 , Rubber Bush: Bottom Cart Part No 12.005.08.0.00 , Support For Push Rod Tube Cart Part No 12.005.09.0.00 , Joint: Push Rod Tube Support Cart Part No 12.005.11.0.00 , V Belts A40 Cart Part No 12.020.03.0.00 , V Belt A-54 Cart Part No 12.034.01.0.00 , Cogged V Belt - Ax-54 Cart Part No 12.034.02.0.00 , Vsc Arrgmt.Cable Type Cart Part No 12.042.10.0.00 , Vsc Unit Assly With Bkt.& Cable.- Remote Cart Part No 12.143.10.0.00 , Fuel Pipe: Tank To Feed Pump Ta1/Ta2 Cart Part No 13.027.02.0.00 , Air Cleaner Element-Av2 Cart Part No 13.046.07.0.00 , O-Ring(28 Idx2.5,21509 Cart Part No 16.014.19.0.00 , Plug-Nylon Cart Part No 16.014.21.0.00 , Decom.Arrangement. Cart Part No 16.016.70.0.00 , Hollow Dowel Cart Part No 16.051.11.0.00 , Ring Set- Sv1 (Std.) Cart Part No 18.006.51.0.00 , Gasket-Head(Corpac)(Tv1/Ak65) Cart Part No 18.009.03.0.00 , Fuel Oil Strainer Cart Part No 18.011.26.0.00 , Filter Casing Assembly (Metallic Plug) Cart Part No 18.026.40.0.00 , Dipstick Assly With O Ring S/F Single Cyl.E Cart Part No 18.026.50.0.00 , Oil Filling Body - Tv1 Cart Part No 18.034.17.0.00 , Cap For Fuel Tanknew Cart Part No 18.051.61.0.00 , Dipstick Assembly Metallic Cart Part No 18.067.30.0.00 , Flexible Pipet To F Cart Part No 18.078.02.0.00 , Starter Ring Cart Part No 18.097.05.0.00 , Camshaft Extension Shaft 4.437Long Cart Part No 18.137.01.0.00 , Intermediate Bearing Housing Assly Tv2 Cart Part No 19.002.30.0.00 , Cr Shaft Cart Part No 19.003.30.0.00 , Cogged V Belt - Ax-53 Cart Part No 19.190.02.0.00 , Oil Seal Flywheel End 73 Od Clockwise Cart Part No 19.216.03.0.00 , Oil Seal Flywheel End Cart Part No 19.216.04.0.00 , Main Brg.Hsg(Fwe)Fw Hsg+Main Brg. Cart Part No 19.216.30.0.00 , Main Brg Hsg(Fwe) Fw Hsg+Main Brg Cart Part No 20.007.30.0.00 , Anti Vibration Mounts Cart Part No 20.367.01.0.00 , Joint For Adaptor Cart Part No 21.115.03.0.00 , Joint: Exh Adaptor Cart Part No 21.115.04.0.00 , Support For Altbracket Cart Part No 21.255.01.0.00 , Pulley For Alternator Cart Part No 21.255.02.0.00 , Lever Belt Tension For Alternator Cart Part No 21.255.03.0.00 , Alternator Bracket Finishe Series Agri Engines Cart Part No 21.255.06.0.00 , Extension Shaft For Crank Pulleyfinishbolted Crpulley Cart Part No 21.267.06.0.00 , Bolt For Crank Pulley Cart Part No 21.267.07.0.00 , Adaptor For Pressure Switch Cart Part No 21.279.02.0.00 , Lube Oil Press Sendor 0.75 +/- 0.15 B Cart Part No 21.279.04.0.00 , Adaptor For Sender Unit Cart Part No 21.343.01.0.00 , Wet Pm Kit (W/O Oil) For 21.1042 Cart Part No 21.999.08.0.Sp , Plug For Breather Tube Cart Part No 22.078.04.0.00 , Rubber Sleeve(12Dia) Cart Part No 22.118.01.0.00 , Rubber Sleeve (20Dia) Cart Part No 24.083.01.0.00 , Hard Washerbar Cart Part No 29.213.09.0.00 , R.E.Bearing M6 Rh Threads Cart Part No 29.224.28.0.00 , R.E.Bearing M6 Lh Threads Cart Part No 29.224.29.0.00 , Crankcase Assembly Cart Part No 2H.001.50.0.00 , Cam Shaft & Gear Assembly Cart Part No 2H.003.10.0.00 , Retaining Plate For Intermediate Gear Cart Part No 2H.004.04.0.00 , Support For Intermediate Gear Cart Part No 2H.004.11.0.00 , Joint: Gear Cover Cart Part No 2H.005.11.0.00 , Oil Seal Housing: Flywheel End Cart Part No 2H.006.01.0.00 , Joint For Oil Seal Housing Cart Part No 2H.006.11.0.00 , Plate: Rubber Moulding Cart Part No 2H.006.20.0.00 , O Ring: Cylinder Liner Cart Part No 2H.008.07.0.00 , Cyl Liner Assembly Cart Part No 2H.008.10.0.00 , O Ring: Cylinder Liner- Viton Cart Part No 2H.008.11.0.00 , Piston Assembly Cart Part No 2H.009.10.0.00 , Piston Ring Set 105 Dia Cart Part No 2H.009.30.0.00 , Piston Ring Set Cart Part No 2H.009.35.0.00 , Piston Ring Set Cart Part No 2H.009.55.0.00 , Hub: Fuel Pump Gear Cart Part No 2H.011.02.0.00 , Delivery Body Cart Part No 2H.013.01.0.00 , Delivery Body Cart Part No 2H.013.10.0.00 , Joint: Delivery Body Cart Part No 2H.013.11.0.00 , Delivery Tube Cart Part No 2H.014.01.0.00 , O Ring: Delivery Tube Cart Part No 2H.014.02.0.00 , Fuel Pump Cover With Joint Cart Part No 2H.017.10.0.00 , Joint For Cover For Fuel Pump Gear Cart Part No 2H.017.11.0.00 , Cover For Hydraulic Pump Gear Cart Part No 2H.018.01.0.00 , Joint: Hydraulic Pump Cover Cart Part No 2H.018.11.0.00 , Oil Metering Orifice Cart Part No 2H.022.06.0.00 , Injector Yoke Cart Part No 2H.023.01.0.00 , Injector Cart Part No 2H.023.10.0.00 , Nozzle Cart Part No 2H.023.91.0.00 , Clip For Breather Pipe Cart Part No 2H.028.03.0.00 , Joint: Air Inlet Manifold Cart Part No 2H.032.11.0.00 , Crank Pulley Cart Part No 2H.034.01.0.00 , Alternator Pulley Cart Part No 2H.034.02.0.Pr , Precoated Drain Plug Cart Part No 2H.035.02.0.00 , Drain Plug Assembly Cart Part No 2H.035.10.0.00 , Gear Casing Cart Part No 2H.036.01.0.00 , Gear Casing Cart Part No 2H.036.02.0.00 , Front Cover Cart Part No 2H.037.04.0.00 , Timing Pointer Cart Part No 2H.037.06.0.00 , Joint: Front Cover Cart Part No 2H.037.11.0.00 , Thrust Washer Cart Part No 2H.038.02.0.00 , Assly Intermediate Gear & Bush Cart Part No 2H.038.10.0.00 , Plate With Rubber Moulding: Oil Seal Housing Cart Part No 2H.039.10.0.00 , Earthing Bolt Of M10x35 For Shanti Projectrolled Brass Type Cart Part No 2H.046.03.0.00 , Earthing Nut For Shanti Brass M10x1 5 Cart Part No 2H.046.04.0.00 , Earthing Washerm10 Brass Cart Part No 2H.046.05.0.00 , Fuel Pump Cart Part No 2H.048.10.0.00 , Inline Fip For 2R1040 G1 Engine25 5 Hp 1500 Rpmcpcb Ii Cart Part No 2H.048.11.0.00 , Hose: Fuel Filling Hose 10 & 15 Kva Genset Cart Part No 2H.059.12.0.00 , Worm Drive Hose Clip (20-25 Mm) Cart Part No 2H.064.03.0.00 , Hose Thermostat To Radiator Cart Part No 2H.065.01.0.00 , Pipe Radiator To Pump Inlet Cart Part No 2H.065.02.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 2H.065.03.0.00 , Hose: Thermostat To Radiator Cart Part No 2H.065.06.0.00 , Hose: Radiator Outlet To Pump Inlet Cart Part No 2H.065.07.0.00 , Suction Tube Assembly Cart Part No 2H.071.30.0.00 , Leak Off Pipe Cart Part No 2H.088.03.0.00 , Leak Off Pipe Assly Cart Part No 2H.088.10.0.00 , Combined Leak Off Pipe: M12 Union Cart Part No 2H.088.20.0.00 , Lube Oil Pressure Sendor Cart Part No 2H.092.11.0.00 , Air Inlet Manifold Cart Part No 2H.094.01.0.00 , Inlet Manifold Cart Part No 2H.094.02.0.00 , R-121 Avr Cart Part No 2H.1025.10.0.00 , Joint: Rocker Cart Part No 2H.107.02.0.00 , Joint For Rocker Cover Cart Part No 2H.107.04.0.00 , Rocker Cover Cart Part No 2H.107.10.0.00 , L Oheader Assembly Cart Part No 2H.109.10.0.00 , Spring Band Clip Cart Part No 2H.112.01.0.00 , Worm Drive Clamp (29 To 45 Dia) Cart Part No 2H.112.02.0.00 , Spring Clamp (Constant Pressure Clamp) Cart Part No 2H.112.06.0.Pr , Hose Clamp 12 To 18 Mm Jupiter Cart Part No 2H.112.07.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 2H.116.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 2H.116.02.0.00 , Fuel Inlet Pipem14x15 Banjo M16x15 Union Nut Cart Part No 2H.116.12.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 2H.116.14.0.Pr , Fuel Inlet Pipe (M14x1.5 Banjo ) Cart Part No 2H.116.21.0.00 , Fuel Pipe Return With M14 Male Plug M14x1 5 Banjo Cart Part No 2H.116.22.0.00 , Pipe Union Bolt (M14 X 1.5) Cart Part No 2H.116.23.0.00 , Fuel Pipe Return With M12 Male Plugm14x1 5 Banjo Cart Part No 2H.116.26.0.Pr , Anti Vibration Mounts Cart Part No 2H.122.01.0.00 , Anti Vibration Mounts Cart Part No 2H.122.03.0.00 , Crankcase Foot (Gear End,Fuel Pump Side) Cart Part No 2H.124.03.0.00 , Crankcase Foot (Gear End,Starter Side) Cart Part No 2H.124.04.0.00 , Support For Mounting Foot Cart Part No 2H.124.05.0.00 , Bracket For Fuel Filter Cart Part No 2H.127.41.0.00 , 72V Dc Coil For Solenoid Drain Valve Cart Part No 2H.131.27.0.00 , Expansion Bellow: Exh Mfold Cart Part No 2H.135.02.0.00 , Expansion Bellow: Two Ply Cart Part No 2H.135.03.0.00 , Radiator Balance Water Tank Cart Part No 2H.139.05.0.00 , Radiator Fan: 15 Dia Pusher Cart Part No 2H.139.07.0.00 , Radiator Fan 17 Cart Part No 2H.139.65.0.00 , Copper Radiator Assembly Cart Part No 2H.139.70.0.Pr , Aluminium Radiator Assembly Cart Part No 2H.139.75.0.00 , Canopy Door Bidding 18Mm Dia. Bulb For Cpcb Project( 1 No = 1 Mtr ) Cart Part No 2H.148.01.0.00 , Canopy Door Switch2a250v Push To Off Cart Part No 2H.148.11.0.Pr , Silencer Cart Part No 2H.154.01.0.00 , Flange (At Silencer Inlet & Outlet) For 2R1040,3R1040 Silent Set Cart Part No 2H.154.02.0.00 , Silencer Flange Vave Cart Part No 2H.154.04.0.00 , Battery Stud For 17 5 Kva Silent Set Cart Part No 2H.160.04.0.00 , Silencer Assembly Cart Part No 2H.161.20.0.00 , Breather Pipe Cart Part No 2H.164.01.0.00 , Fuel Tank Unit S F 219 Effective Tank Height Cart Part No 2H.1649.31.0.Pr , Fuel Tank Unit S/F 230 Effective Tank Height Cart Part No 2H.1649.33.0.Pr , Silencer Cart Part No 2H.174.10.0.00 , Fuel Tank Unit Cart Part No 2H.177.19.0.Pr , Silencer Cart Part No 2H.188.10.0.00 , Bend For Tail Pipe Cart Part No 2H.193.02.0.00 , Feed Pump Cart Part No 2H.201.10.0.00 , Flywheel Assembly Cart Part No 2H.205.10.0.00 , Battery Charger Dc To Dc Converter I P Supply 60 To 90 Vdc Cart Part No 2H.226.26.0.00 , Dc Cti P0 150Ampo P 0 5 Vdccontrol Volatge5vdc 24Mm Id Cart Part No 2H.226.28.0.00 , Power Relay, 1 C/O, 2 Ch, 12V Dc, 70A Cart Part No 2H.226.32.0.00 , Relay, 2 C/O , 2Ch, 12Vdc, 5A Cart Part No 2H.226.33.0.00 , Battery Clamping Stud (M8) Cart Part No 2H.228.02.0.00 , Connector Assly: Control Panel With Kg934 Cart Part No 2H.241.60.0.00 , Connector Assembly For Control Panel With Kg645 Unit Cart Part No 2H.241.70.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.268.20.0.00 , Engine Wiring Harness For 2R1040 Engine Cart Part No 2H.268.50.0.Pr , Engine Wiring Harness For 2R 20Kva Emerald Cart Part No 2H.268.70.0.Pr , Engine Wiring Harness Assembly Cart Part No 2H.269.50.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.269.60.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.269.70.0.00 , Rubber Hose: Air Cleaner Cart Part No 2H.277.03.0.00 , Primary Air Cleaner Element Cart Part No 2H.277.05.0.00 , Vacuuator Valve For Air Cleaner Cart Part No 2H.277.06.0.00 , Safety Element Forair Cleaner Cart Part No 2H.277.09.0.00 , Pvc Pipe For Air Cleaner Cart Part No 2H.277.19.0.00 , Air Cleaner Assly+ Strainer Cart Part No 2H.277.20.0.00 , Hose For Pvc Pipe Cart Part No 2H.277.21.0.00 , Hose For Pvc Pipe Cart Part No 2H.277.23.0.00 , Bracket For Air Cleaner Cart Part No 2H.277.24.0.00 , Hose For Air Cleaner Cart Part No 2H.277.26.0.00 , Assembly Of Air Cleaner (Air Cleaner + Strap + Rain Cap) Cart Part No 2H.277.40.0.00 , Dry Type Air Cleaner Assly For 2R Cart Part No 2H.277.90.0.00 , Adaptor For Lub Oil Pressure Switch Cart Part No 2H.279.21.0.00 , Starter 12Vdc 2 7Kw Suitable For 20 Deg Cart Part No 2H.301.02.0.Pr , Wet Pm Kit (W/O Oil ) For 2H.3014 - 2R1040 Cart Part No 2H.301.04.0.Sp , Wet Pm Kit (W/O Oil) For 2H.3017,2H.3020,2H.8303,2H.8306,2H.9024 - Model : 2R1040 Cart Part No 2H.301.7.0.Sp , Starter 12V 2.7Kw With Sealing Feature Cart Part No 2H.302.02.0.00 , 4 Pole 40 Amp Mcb Cart Part No 2H.313.01.0.00 , Pipe For Fuel Tank Breather With M12 X 1.5 Union Cart Part No 2H.316.08.0.00 , Anti Vibration Mounts Cart Part No 2H.332.01.0.00 , Anti Vibration Mounts Cart Part No 2H.332.02.0.00 , Anti Vibration Mounts Cart Part No 2H.332.04.0.00 , Anti Vibration Mount Cart Part No 2H.332.05.0.00 , Anti Vibration Mount For Radiator Cart Part No 2H.332.08.0.Pr , Sealing Washer Cart Part No 2H.345.32.0.Pr , Plastic Fuel Filling Spout With Lock Mesh Cart Part No 2H.345.36.0.Pr , Current Transfarmor 50/5, 2.5 Va Cart Part No 2H.467.04.0.00 , Amf Control Panel For 14Kw Dg Setreliance Jio Cart Part No 2H.471.40.0.00 , Coil, 220V Ac, 50Hz, Contactor 4 Pole, Type: Type-Lc1e80004m5wb) Cart Part No 2H.471.86.0.00 , Conversion Kit Kg934 To Kg645w O Controller For Dc Interface Card Cart Part No 2H.472.30.0.Pr , Conversion Kit Kg934 To Kg645w O Controllerfor Ac Dc Interface Card Old Type Cart Part No 2H.472.40.0.Pr , Canopy Wiring Harness For 2R1040 Genset Cart Part No 2H.481.40.0.Pr , Hose: Air Cleaner Cart Part No 2H.542.06.0.00 , Expansion Bellow 270Mm Cart Part No 2H.545.01.0.00 , Pad Lock For Canopy Cart Part No 2H.561.32.0.00 , Control Panel Schematic For 20Kva3ph With Kg640 Ip A Cart Part No 2H.764.60.0.Pr , Varistor For Kgs 160And Kgs180 Alt. Frame Alt. Frame Cart Part No 2H.811.05.0.00 , Kirloskar Green Avr (Model : Tavr-10/Tavr-20/Tavr-14 Cart Part No 2H.811.32.0.00 , Koel Green Avr: Suitable To External Adjust Potentiometer Cart Part No 2H.811.33.0.00 , Rotating Rectifier Assembly With Forward And Reverse Diode Cart Part No 2H.811.35.0.00 , Excitor Rotor Assembly(16A105) S/F Kg164e,Kg164f,Kg164g Cart Part No 2H.811.36.0.00 , Excitor Rotor Assembly(16S105)S/Fkg164h,Kg164j,Kg184a,Kg184b,Kg184c,Kg184d Cart Part No 2H.811.37.0.00 , Excitor Stator Assembly(16A106)S/Fkg164e,Kg164f,Kg164g Cart Part No 2H.811.38.0.00 , Excitor Stator Assembly(16S106)S/Fkg164h,Kg164j,Kg184a,Kg184b,Kg184c,Kg184d. Cart Part No 2H.811.39.0.00 , Terminal Block(16A110)S/F Kg.164E,Kg164f,Kg164g,Kg164h,Kg164j,Kg184a,Kg184b,Kg184 Cart Part No 2H.811.42.0.00 , Fan With Key For 164 Frame (16A108) Cart Part No 2H.811.43.0.00 , Flexible Discs Cart Part No 2H.811.73.0.00 , Koel Green Alternatorkg 20 S T Framel Kg 40 Hsae 2 11 5 415V50 Hz0 8 Pf Cart Part No 2H.817.14.0.Pr , Koel Green Alternatorkg 20 S S Framel Kg 42 3 Csae 2 11 5 230V50 Hz0 8 Pf Cart Part No 2H.818.14.0.Pr , D120 Avr Cart Part No 2H.818.15.0.00 , Koel Green Alternator Kg42 3Csae3 11 520Kva 20Kw At Upf230 V50 Hz Cart Part No 2H.818.16.0.Pr , Avr (Model- Tavr27) Cart Part No 2H.818.35.0.00 , Wet Pm Kit (W/O Oil) For 2H.8307.10 Cart Part No 2H.830.7.0.Sp , Fuel Level Sensor 110Mm Height(Pricol C20 5289) Cart Part No 2H.850.14.0.00 , Hour Meter Cart Part No 2H.857.06.0.Pr , Indicating Lamp 12 V Dc Green Colour Type-3Plbr3l Cart Part No 2H.864.12.0.00 , Indicating Lamp 12 V Dc Red Colour Type-3Plbr4l Cart Part No 2H.864.13.0.00 , Control Relay 12Vdc 3Chanel Cart Part No 2H.865.52.0.00 , Canopy Temperature Switch 2 - 85 Deg C Cart Part No 2H.865.56.0.00 , Neutral Linck 10 A Capacity Cart Part No 2H.866.07.0.00 , Earthing Cable (Braded) Forgenset 4Mm Dia. With Suitable Lug. Alt. To Base Plate Cart Part No 2H.868.02.0.00 , Lvm: 2C/O 3Ph Wo Phase Sequence Monitoring Cart Part No 2H.871.05.0.00 , Battery Charger 12V10a Cart Part No 2H.872.23.0.Pr , Digital Line Voltage Monitor Pr-07 Cart Part No 2H.875.02.0.00 , Selector Switch 3 Way With Off, 3 Pole Cart Part No 2H.876.04.0.00 , Relay Board 2Ch. 2C/O 12 V Din Mounted Cart Part No 2H.876.05.0.00 , Current Transformer 200 5A 2 5Va Cl 1 0Typene 310 Cart Part No 2H.880.11.0.Pr , 1 Amp Single Pole Mcb Cart Part No 2H.881.05.0.00 , 0 5 Amp Single Pole Mcb Cart Part No 2H.881.07.0.Pr , Fuse Blown Indicator 12 /24 Vdc Black Colour R Cart Part No 2H.892.09.0.00 , End Plates For4 Sq Mmterminal Stripsqty As Req Cart Part No 2H.892.12.0.00 , Water Tempsensor Cart Part No 2H.910.01.0.Pr , Mandrel For Intermediate Gear Mounting With Bush Cart Part No 2H.950.10.0.00 , Gasketfor L Series Governor Mounting Cart Part No 2H.956.01.0.00 , Header (For Locooler & Spin-On-Filter) Cart Part No 2H.964.01.0.00 , Header For Lube Oil Cooler & Spin On Filter (3 Plates) Cart Part No 2H.964.03.0.00 , Header: Spin On Filter Wo Cooler Cart Part No 2H.964.04.0.00 , Crankshaft Assembly Cart Part No 2H.966.10.0.00 , Crankshaft Assembly Cart Part No 2H.966.20.0.00 , 12V Relay Board-70 Amp Cart Part No 2H.970.02.0.00 , Auxillary Contact Block 2No 2Nctype Laen22 Cs94114oooo Cart Part No 2H.974.32.0.00 , Auxillary Contact Block Cart Part No 2H.974.37.0.Pr , Mcb 10A 1P C Curvetype A9n1p10c Bb10100c Cart Part No 2H.974.42.0.Pr , Contactor 100A 4P Ac1 With 220Vac Coil Type Cart Part No 2H.974.46.0.00 , Mechnical Inter Lock Type Laem4 Cs93095oooo Cart Part No 2H.974.47.0.Pr , Surge Suppressor Type Laercu Cs94163booo Cart Part No 2H.974.48.0.Pr , Mccb 100A 2P 3Ptype Ezc100h2100 Du100 Cart Part No 2H.974.55.0.Pr , Contactor 60A 63A 4P Ac1 With220vac Coiltype Lc1e38004m5wb240vac Coilcs970 Cart Part No 2H.974.58.0.Pr , Contactor Mcx1380a4pac1 With 240Vac Coil Voltage Cart Part No 2H.974.63.0.Pr , Mcb6a,1Pc-Curve,Type-Auseries Cart Part No 2H.974.66.0.Pr , Mcb2a,1Pc-Curve Cart Part No 2H.974.69.0.Pr , Contactor 95 A 3P Ac1 With (240Vac Coil, Type- Lc1e95u5/ 240Vac Coil) Cart Part No 2H.974.82.0.Pr , Mcb4a,1Pc-Curve Cart Part No 2H.974.91.0.Pr , Mcb 32A,1P C-Curve, Type-Au Series Cart Part No 2H.974.92.0.Pr , 100A Wide Band Contactor-240V,50Hz Cart Part No 2H.974.93.0.Pr , Terminal Bar- 30/40 Kva 1 Phase, 45/75Kva 3Phase Cart Part No 2H.976.01.0.00 , Exciter Rotor Cart Part No 2H.976.07.0.00 , Rra Aassembly Cart Part No 2H.976.08.0.00 , Wound Exciter Rotorrating5 To 12 5 Kva 1Ph7 5 To 20 Kva 3Ph Sem040ro002b Fr Cart Part No 2H.976.17.0.00 , Wound Exciter Statorrating5 To 12 5 Kva 1Ph7 5 To 20 Kva 3Ph Sem040st001b Fr Cart Part No 2H.976.18.0.00 , Fan, Rating 5 To 12.5 Kva Cart Part No 2H.976.19.0.00 , Coupling Disk Sae 11.5 (Ag318196) Cart Part No 2H.976.22.0.00 , De Flange Sae 3 Rating5 To 12 5 Kva 1Ph 7 5 To 20 Kva 3Phpma046pu002bframekg4 Cart Part No 2H.976.23.0.00 , Nde Flange (Mc),Rating-5 To 12.5 Kva 1Ph,7.5 To 20 Kva 3Ph,(Pma029pu003b),Frame-Kg40 Cart Part No 2H.976.24.0.00 , Terminal Bar,Rating-5 To 12.5 Kva 1Ph,7.5 To 20 Kva 3Ph,(Pla092ai002b),Frame-Kg40 Cart Part No 2H.976.25.0.00 , Cylinder Head Assembly Cart Part No 2H.979.30.0.00 , Valve Rocker Assembly Cart Part No 2H.982.20.0.00 , Cylinder Head Assemblysingle Jacket Cart Part No 2H.983.30.0.00 , 100 Ampcontactor Assembly Cart Part No 2H.999.07.0.Sp , Set Of Joints 2R1040 G1 Cpcb Ii Engine Cart Part No 2H.999.10.0.Sp , Wet Pm Kit (W/O Oil) For 2H.3005, 2H.3010 - 2R1040 Cart Part No 2H.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 2H.8322,2H.8322.Pb,2H.8307-2R1040 G1 Cart Part No 2H.999.14.0.Sp , Thermostat Element 60C Cart Part No 30.182.01.0.00 , Hose Clip Cart Part No 30.650.02.0.00 , Protection Cap Cart Part No 30.735.06.0.00 , Plain Washer For Bearing Cap Cart Part No 34.001.07.0.00 , Nut: Cyl Head Stud M14x1.5 Cart Part No 34.001.18.0.00 , Dome Nut Cart Part No 34.001.19.0.00 , Dowel For Gear Casing Cart Part No 34.001.23.0.00 , Plain Washer Cart Part No 34.001.29.0.00 , Precoated Plugfor Oil Gallery Cart Part No 34.001.35.0.00 , Key For Crank Shaft Cart Part No 34.003.02.0.00 , Crankshaft Plug - Aluminium Cart Part No 34.003.07.0.00 , Washer For Aluplug Cart Part No 34.003.08.0.00 , Crankshaft Gear Cart Part No 34.005.01.0.00 , Crankshaft Gear Cart Part No 34.005.02.0.00 , Intermediate Gear Cart Part No 34.007.20.0.00 , Thrust Plate Cart Part No 34.009.02.0.00 , Valve Tappet Cart Part No 34.010.06.0.00 , Cup For P R Tube Cart Part No 34.011.02.0.00 , Spring For Push Rod Tube Cart Part No 34.011.05.0.00 , Rubber Bush Top Cart Part No 34.011.06.0.00 , Rubber Bush Bottom Cart Part No 34.011.07.0.00 , Oil Sealfwe 100 X 120 X 12Ptfe Cart Part No 34.012.05.0.00 , Oil Seal: Cr Seal Cart Part No 34.012.12.0.00 , Oil Seal: Gear End Cart Part No 34.012.13.0.00 , Valve Seat Insert: Inlet Cart Part No 34.013.03.0.00 , Valve Seat Insert: Exhaust Cart Part No 34.013.04.0.00 , Valve Guide Cart Part No 34.013.05.0.00 , Stud For Rocker Support Cart Part No 34.013.06.0.00 , Stud For Rocker Support Cart Part No 34.013.07.0.00 , Valve Guide Cart Part No 34.013.08.0.00 , Cup For Valve Spring Cart Part No 34.013.13.0.00 , Valve Stem Seal Cart Part No 34.013.19.0.00 , Valve Cart Part No 34.013.70.0.00 , Joint: Fuel Pump Cart Part No 34.016.12.0.00 , Banjo Bolt With Strainer Cart Part No 34.016.15.0.00 , Feed Pump W/O Bowl Filter Cart Part No 34.016.40.0.00 , Leak Off Pipe Cart Part No 34.016.60.0.00 , Fuel Pump Gear Cart Part No 34.017.04.0.00 , Washer For Fuel Pump Gear Cart Part No 34.017.05.0.00 , Lube Oil Pump Assly Cart Part No 34.018.10.0.00 , Jt For L O P Body Cart Part No 34.020.02.0.00 , O Ring : Del Body 2.7X17-21516 Cart Part No 34.020.03.0.00 , Delivery Body Cart Part No 34.020.20.0.00 , Joint: Lube Oil Filter Adaptor Cart Part No 34.021.05.0.00 , Joint For L.O.Filter Adaptor (Sspl-Ss/Ko/1194) Cart Part No 34.021.06.0.00 , Banjo Bolt Cart Part No 34.023.06.0.00 , Piston Pin Cart Part No 34.025.24.0.00 , Dowel For Con Rod Cart Part No 34.026.02.0.00 , Connecting Rod Bolt Cart Part No 34.026.03.0.00 , Relief Valve Assly Cart Part No 34.028.20.0.00 , Banjo Bolt : 10X1 Cart Part No 34.030.05.0.00 , Sealing Ring: Fuel Filter Cart Part No 34.032.01.0.00 , Prefilter Element Cart Part No 34.032.02.0.00 , Fuel Filter Element Cart Part No 34.032.03.0.00 , Fuel Filter Element Cart Part No 34.032.12.0.00 , O F Valve Assly Cart Part No 34.032.60.0.00 , Leak Off Pipe Connection Cart Part No 34.034.05.0.00 , Fuel Pipe 90,14X14 B,260 Wb Cart Part No 34.035.03.0.00 , Perforated Disc Cart Part No 34.036.50.0.00 , Cap Assly Cart Part No 34.036.60.0.00 , Joint: Flange/Fuel Spout Cart Part No 34.040.02.0.00 , Clip For Rain Cap Mounting On Exhaust Silencer Cart Part No 34.042.02.0.00 , Starter Ring Cart Part No 34.043.02.0.00 , Dowel Cart Part No 34.046.02.0.00 , Flywheel Bolt: M14x15x40 Cart Part No 34.046.05.0.00 , Flywheel Bolt: M14x15x45 Cart Part No 34.046.07.0.00 , V Belt A56 Cart Part No 34.053.01.0.00 , Pin For Stopping Cable Cart Part No 34.077.05.0.00 , Diaphragm Cart Part No 34.084.01.0.00 , Joint: Rocker Cover Cart Part No 34.088.02.0.00 , Start/Stop Button 12V/24V40a Cart Part No 34.101.03.0.00 , Joint Ss: Adaptor On Ex Mfold Cart Part No 34.107.06.0.00 , Gasket (For Inlet Air Heater) Cart Part No 34.107.12.0.00 , Fuel Pipe 7.5 14X14 B 700 Wb Cart Part No 34.151.01.0.00 , Clip For Flexible Pipe With Sleeve Cart Part No 34.151.03.0.00 , Fuel Pipe 7.5 14X14 B 700 Pb Cart Part No 34.151.04.0.00 , Clip For Flexible Pipe With Sleeve Cart Part No 34.151.06.0.00 , Fuel Pipe: Wire Braided Cart Part No 34.174.01.0.00 , Lube Oil Temp Gauge Cart Part No 34.183.03.0.00 , Adaptor For Pressure Switch Cart Part No 34.184.01.0.00 , Pressure Switch 0.8 To 1.2 Cart Part No 34.184.02.0.00 , Pin Cart Part No 34.188.05.0.00 , Joint For Blanking Plate Non Asbestos Cart Part No 34.242.11.0.00 , Flexible Pipe: Lop Gauge Cart Part No 34.250.02.0.00 , Flange For 20 Flexible Exhaust Pipe Cart Part No 34.265.03.0.00 , Spacer Cart Part No 34.312.03.0.00 , Intermediate Gear Cart Part No 34.341.10.0.00 , Flywheel Pulling Stud And Bolt Cart Part No 34.950.07.0.00 , Push Rod Kit Cart Part No 34.990.01.0.00 , Oil Seal(Spr.)Indg. Cart Part No 34.999.02.0.00 , Fuel Filter Kit 0.5 Ltr Cart Part No 34.999.15.0.00 , High Pressure Pipe Assembly Cart Part No 35.008.70.0.00 , V Belt A55 Cart Part No 35.047.01.0.00 , Fuel Pipe 8Mm Id 14X14b 2M Long Pb Cart Part No 35.107.01.0.00 , Fuel Pipe: 8.0 14X14 B 2500L Pb Cart Part No 35.107.02.0.00 , Ext Nozzle Leak Off: 4.4 14Bx12u, 2500Pp Cart Part No 35.107.03.0.00 , Starter 12V Cart Part No 36.010.06.0.00 , H P Pipe Setcomplete Bend Rb01 Fwe Cart Part No 36.011.80.0.00 , Fuel Pipe 8.0 14 B 1000 Wb Cart Part No 36.040.01.0.00 , Fuel Pipe Cart Part No 36.040.03.0.Pr , Joint Ring: Liner Cart Part No 38.002.03.0.00 , Joint: Cyl Liner To Block Cart Part No 38.002.06.0.00 , Joint Liner To Head0 25 Mm Cart Part No 38.002.13.0.00 , Tube Cart Part No 38.002.15.0.00 , Sealing Ring: Water Ferrule Cart Part No 38.002.18.0.00 , V Belt B46 Cart Part No 38.006.01.0.00 , Joint: Water Pump Volute Cart Part No 38.009.05.0.00 , Joint: Water Inlet Manifold Cart Part No 38.013.11.0.00 , Joint: Water Outlet Manifold Cart Part No 38.014.11.0.00 , W T Gauge 3.6 Cap 40-100 Cart Part No 38.022.11.0.00 , Water Temp Gauge 1.8M Cart Part No 38.027.02.0.00 , Stud For Gear Casing Cart Part No 38.054.01.0.00 , V Belt: B47 1237 Long Cart Part No 38.066.01.0.00 , Set Of Joints Cart Part No 38.100.10.0.00 , Fuel Pipe: 400Mm Cart Part No 38.156.01.0.00 , Fuel Pipe: 9.0 14X14b 520 Wb Cart Part No 38.156.02.0.00 , Set Of O Rings Cart Part No 38.164.10.0.00 , Hose: Radiator To Pump Cart Part No 38.167.14.0.00 , Hose: Engine To Radiator Cart Part No 38.167.15.0.00 , Valve Guide Cart Part No 38.181.02.0.00 , Valve Seat Insert Exhaust Cart Part No 38.181.03.0.00 , Valve Pair Cart Part No 38.181.70.0.00 , Lube Oil Filter Assly Cart Part No 38.195.20.0.00 , Cylinder Head Bolt: Short Cart Part No 38.196.02.0.00 , Cyl Head Stud: Long Cart Part No 38.196.03.0.00 , Gasket: Cylinder Head 1.2Mm Thk Cart Part No 38.197.05.0.00 , Cyl Head Steel Gasket 0.80 Mm Thk Cart Part No 38.197.06.0.00 , Cyl Head Steel Gasket 1.0Mm Thk Cart Part No 38.197.07.0.00 , Cyl Head Steel Gasket 1.2 Mm Thk Cart Part No 38.197.08.0.00 , Cyl Liner Assembly Cart Part No 38.197.10.0.00 , Piston Ring Set Cart Part No 38.198.30.0.00 , Piston Assembly Cart Part No 38.198.90.0.00 , Push Rod Tube Assembly Cart Part No 38.201.10.0.00 , Water Pump Assembly Cart Part No 38.207.40.0.00 , Fuel Filter With Sealing Wire Cart Part No 38.226.03.0.00 , Leak Off Pipe Sub Assly Cart Part No 38.258.10.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 38.260.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 38.260.03.0.00 , Hose: Water Outlet Manifold To Radiator Cart Part No 38.260.04.0.00 , Aluminium Radiator For Rv2 Cpcb Engines Cart Part No 38.260.90.0.00 , Cogged V Belt: B X47 Cart Part No 38.359.01.0.00 , Anti Vibration Mounts Cart Part No 38.394.01.0.00 , Wet Pm Kit (W/O Oil) For 38.1325, 39.1302- Rv3 G-Drive Cart Part No 38.999.77.0.Sp , Fuel Pipe: 7.5 14X14b 320 Wb) Cart Part No 39.027.22.0.00 , Ball Joint Assy Cart Part No 39.032.10.0.00 , Thermostat Element 74? Cart Part No 39.040.09.0.00 , Fuel Connectionfor M14 Banjo Bolt Cart Part No 39.092.10.0.00 , Set Of Joints For Swaraj 735 Tractor Cart Part No 39.130.10.0.00 , Hose: Radiator Cart Part No 39.169.02.0.00 , Water Pump Assly With Pulleyrv 3 Std Cart Part No 39.170.10.0.00 , Set Of Joints Cart Part No 39.173.10.0.00 , Set Of High Pressure Pipes Cart Part No 39.179.10.0.00 , Crankcase (Lh) Assembly Cart Part No 39.185.20.0.00 , Set Of Joints Cart Part No 39.220.10.0.00 , Joint For Lub Oil Sumpc Isump Cart Part No 39.224.02.0.00 , Water Pump Assly: 120 Pcd Cart Part No 39.230.10.0.00 , Hose: Water Pipe To Tee Connection Cart Part No 39.231.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 39.231.03.0.00 , Leak Off Pipe Sub Assly Cart Part No 39.236.10.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 39.237.02.0.00 , Combined Leak Off Pipe Cart Part No 39.238.10.0.00 , Drain Pipe: Lube Oil Sump Cart Part No 39.240.01.0.00 , Wet Pm Kit (W/O Oil) For - 39.3001 - Rv3 Cart Part No 39.300.01.0.Sp , Fip Nut Cart Part No 39.405.03.0.00 , Wiring Harness Engine To Control Panel Cart Part No 39.901.10.0.00 , Wiring Harness Assly: Eng To Control Cart Part No 39.902.10.0.00 , Wet Pm Kit (W/O Oil) For 39.1335 - Rv3 G Drive Cart Part No 39.999.03.0.Sp , Wet Pm Kit (W/O Oil) For 39.3005… 39.3004... Rv3( Al. Radiator) Cart Part No 39.999.33.0.Sp , Stud(For Front Axle Support) Cart Part No 3H.001.02.0.00 , Crankcase Assembly Cart Part No 3H.001.60.0.00 , Cam Shaft & Gear Assembly Cart Part No 3H.003.10.0.00 , Subassly Of Egr Camshaft For 3R1040ta / Tc Cpcb Ii Cart Part No 3H.003.30.0.00 , Fuel Injection Pump Cart Part No 3H.004.20.0.00 , Lube Oil Pump Assly. Cart Part No 3H.005.10.0.00 , Sub Assly Lo Pump Int Gear & Bush Cart Part No 3H.005.30.0.00 , Assly For Internal Gear Cart Part No 3H.005.60.0.00 , Lube Oil Pump Cart Part No 3H.005.70.0.00 , Suction Tube Cart Part No 3H.006.20.0.00 , Header: Lube Oil Cooler -Filter Cart Part No 3H.007.01.0.00 , Joint: Header Cart Part No 3H.007.02.0.00 , Adaptor For Spin On Filter Cart Part No 3H.007.05.0.00 , Lube Oil Cooler & Header Assly Cart Part No 3H.007.10.0.00 , Lube Oil Cooler (3 Plate) Cart Part No 3H.007.11.0.00 , Joint: Lube Oil Cooler Non Asbestos Cart Part No 3H.007.13.0.00 , Joint: Header Cart Part No 3H.007.15.0.00 , Header For Lub Oil Cooler Spin On Remote Filter Cart Part No 3H.007.18.0.Pr , Lube Oil Cooler Cart Part No 3H.007.19.0.00 , Lub Oil Cooler Header Assly Cart Part No 3H.007.30.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 3H.009.06.0.00 , O Ring: Nozzle Cart Part No 3H.009.11.0.00 , Cylhead With Core Plugs Cart Part No 3H.009.30.0.00 , Oil Metering Orifice (Dia 8) Cart Part No 3H.010.06.0.00 , Valve Rocker Assembly Cart Part No 3H.010.10.0.00 , High Pressure Pipe Assembly Cart Part No 3H.011.10.0.00 , Leak Off Pipe Assly Cart Part No 3H.012.20.0.00 , Inlet Manifold Cart Part No 3H.013.03.0.Pr , Gasket For Air Inlet Manifold Cart Part No 3H.013.04.0.Pr , Joint: Rocker Cover Cart Part No 3H.014.11.0.00 , Joint For Rocker Cover Cart Part No 3H.014.13.0.00 , Inlet Manifold Cart Part No 3H.015.01.0.00 , Joint: Air Inlet Mfold Cart Part No 3H.015.11.0.00 , Adapter For Exhaust Silencer Cart Part No 3H.016.02.0.00 , Exhaust Manifold Cart Part No 3H.016.04.0.00 , Oil Supply Pipefor Fuel Pump Cart Part No 3H.016.08.0.00 , 50 Hrs - A Check Maintenance Kit Cart Part No 3H.019.11.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 3H.019.13.0.Sp , Flywheel Assembly (S/F Ace Tractor) Cart Part No 3H.021.20.0.Pr , Dipstick Assembly Cart Part No 3H.024.10.0.00 , Breather Pipe Cart Part No 3H.028.01.0.00 , Breather Pipe Cart Part No 3H.028.06.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 3H.029.02.0.00 , Lower Clamp(For Radiator Pipe) Cart Part No 3H.029.03.0.00 , Top Clamp(For Radiator Pipe) Cart Part No 3H.029.04.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 3H.029.05.0.00 , Hose For Thermostat To Radiator Cart Part No 3H.029.08.0.00 , Clip For Hose Cart Part No 3H.029.17.0.00 , Gasket (Rocker Cover) Cart Part No 3H.032.04.0.Pr , Rubber Hose : Air Cleaner Cart Part No 3H.034.04.0.00 , Valve Rocker Lever (Assy Complete) Cart Part No 3H.034.30.0.Pr , Front Cover Cart Part No 3H.039.01.0.00 , Cover Plate For Front Cover Compressor Mounting Cart Part No 3H.039.04.0.00 , Joint: Cover Plate Cart Part No 3H.039.05.0.00 , H Ppipefor Cyl1 Cart Part No 3H.040.10.0.Pr , Hppipefor Cyl2 Cart Part No 3H.040.20.0.Pr , Hppipefor Cyl3 Cart Part No 3H.040.30.0.Pr , Hppipepump To Rail Cart Part No 3H.040.40.0.Pr , Hppipepump To Rail Cart Part No 3H.040.50.0.Pr , Pulley: Alternator 68 Pcd Cart Part No 3H.041.02.0.00 , Pulley: Alternator 68 Pcd Spz Cart Part No 3H.041.04.0.00 , Oil Filling Body 57 Mm Height Cart Part No 3H.042.01.0.00 , Joint: Oil Filling Body Cart Part No 3H.042.03.0.00 , Joint: Adaptor Cart Part No 3H.043.03.0.00 , Flywheel Sub Assly. Cart Part No 3H.054.10.0.00 , Cross Member Forradiator Support Cart Part No 3H.057.03.0.00 , Thermostat Assembly Cart Part No 3H.061.10.0.00 , Lub Oil Sumpsheet Metal Cart Part No 3H.064.07.0.Pr , Assembly Dipstick Fabricated Oil Sump Cart Part No 3H.064.30.0.Pr , Set Of Copper Washer Cart Part No 3H.074.10.0.00 , Set Of Joints Cart Part No 3H.074.20.0.Sp , Crank Case Foot ( Starter Side) Cart Part No 3H.079.03.0.00 , Crank Case Foot F W Efuel Pump Side Cart Part No 3H.079.04.0.00 , Dipstick Assembly Cart Part No 3H.082.20.0.00 , Flywheel Housing Cart Part No 3H.085.01.0.00 , Flywheel Housing Cart Part No 3H.085.03.0.00 , Uego Sensor For Gas Engines Cart Part No 3H.086.53.0.Pr , Flywheel Assembly Cart Part No 3H.088.10.0.00 , Adaptor (For Crank Case) Cart Part No 3H.096.04.0.Pr , Crankcase Assly With Mb Cap Cart Part No 3H.096.10.0.Pr , Crankcase Assly With Mb Cap Cart Part No 3H.096.40.0.Pr , Crankshaft Assly With Gear Cart Part No 3H.099.10.0.00 , Fuel Pump F002 A0z 776For 3R1040na49 5Hp 2200 Rpm Cart Part No 3H.1007.01.0.00 , Fip (Plain Element) For 3R1040tc_42Hp@1500Rpm For Cpcbii Cart Part No 3H.1007.04.0.00 , Fuel Injection Pump Cart Part No 3H.1007.05.0.00 , Fip: 3R1040_45Hp@2000Rpm Cart Part No 3H.1007.06.0.00 , Turbocharger Cart Part No 3H.1008.01.0.00 , Turbocharger Cart Part No 3H.1008.04.0.00 , High Pressure Pipe Assembly Cart Part No 3H.1009.60.0.00 , Bracket For Relay Box Mtg Cart Part No 3H.1017.02.0.Pr , Egr Cooler 3 Kw Cart Part No 3H.1018.01.0.Pr , Engine Wiring Harness For 3Rta Crdi Cpcb4engine Cart Part No 3H.1043.10.0.Pr , Engine Wiring Harness For 3Rta 40Kva Crdi Cpcb4engine Cart Part No 3H.1043.50.0.Pr , Oil Supply Pipe (For Turbocharger) Cart Part No 3H.1051.10.0.Pr , Cac Cold Pipe Cart Part No 3H.1053.03.0.00 , Piston Assembly Cart Part No 3H.106.30.0.00 , Piston Assembly Complete Cart Part No 3H.106.60.0.00 , Compressor: Sc160 Cart Part No 3H.107.02.0.00 , Adaptor: Compressor Cart Part No 3H.107.03.0.00 , C Type Stop Lever Cart Part No 3H.113.01.0.00 , Reducing End Cart Part No 3H.113.02.0.00 , Screw Plug Cart Part No 3H.113.03.0.00 , Washer Cart Part No 3H.113.04.0.00 , Gear Casing Cart Part No 3H.115.03.0.00 , Adaptor Plate Cart Part No 3H.120.01.0.00 , Gear Cart Part No 3H.120.02.0.00 , Joint: Adaptor Plate Cart Part No 3H.120.03.0.00 , Digital Rpm Meter Hourmeter Cart Part No 3H.130.01.0.00 , Magnetic Pick Up M16x15 Threading Length 60 Mm Cart Part No 3H.130.03.0.00 , Digital Rpm Meter Hourmeter Cart Part No 3H.130.05.0.00 , Fuel Filter Element Primary Cart Part No 3H.132.01.0.00 , Fuel Filter Element Secondary Cart Part No 3H.132.02.0.00 , Sealing Ring (Fuel Filter) Cart Part No 3H.132.03.0.00 , Spinon Fuel Filter 0.6L Tbowl Cart Part No 3H.132.10.0.00 , Water Jacket Heater Kim Hot Type Tps152gt12 000240V Ac 1500W With 120 140F Ther Cart Part No 3H.133.11.0.00 , Stop Solenoid Assly Cart Part No 3H.135.10.0.00 , Water Connection Cart Part No 3H.136.11.0.00 , Water Connection 0.75- 14 Nptf Threads Cart Part No 3H.136.12.0.00 , Adaptor: Oil Sump Male Both Side Cart Part No 3H.147.03.0.00 , Adaptor: Oil Sump Male Benjo Type Cart Part No 3H.147.04.0.00 , Adaptor: Lube Oil Sump Cart Part No 3H.147.07.0.00 , Adaptor: Lube Oil Drain Cart Part No 3H.147.09.0.00 , Injector Cart Part No 3H.148.01.0.00 , Banjo Bolt Cart Part No 3H.148.53.0.00 , Nozzle Leak Off Pipe:Kva20/25 Cart Part No 3H.151.10.0.00 , Radiator Drain Pipe Cart Part No 3H.153.01.0.00 , Adaptor: Drain Cock Cart Part No 3H.153.02.0.00 , Plug For Drain Cock Cart Part No 3H.153.08.0.00 , Radiator Drain Pipe For 82.5 Kva Internaco Project Cart Part No 3H.153.09.0.00 , Drain Cock Cart Part No 3H.153.11.0.00 , Adaptor With Hose Tail Cart Part No 3H.153.12.0.00 , Adaptor With Hose Tail Cart Part No 3H.153.14.0.00 , Drain Cock Cart Part No 3H.153.21.0.00 , Strip Clamp Cart Part No 3H.160.01.0.00 , Fuel Injection Pump: 3R1040pg Cart Part No 3H.171.10.0.00 , Inlet & Outlet Connection Cart Part No 3H.173.04.0.00 , Breather For Fuel Tank Cart Part No 3H.173.05.0.00 , Leak Off Pipe Assembly Cart Part No 3H.175.10.0.00 , Fuel Inlet Pipe: 20-25Kva 750Mm Long Cart Part No 3H.181.01.0.00 , Fuel Return Pipe Cart Part No 3H.181.02.0.00 , Fuel Pipereturn M12x1 5 Male Plug X M16x1 5Union550mm Lengthfor 10 To 125 Kva Cart Part No 3H.181.03.0.00 , Fuel Pipeinlet M12 1 5Mai Plugm16 1 5 Union For 10 To 125 Kva Trailer Mounted550 Cart Part No 3H.181.04.0.00 , Fuel Pipe Return M12x15 Male Plug X M16x15union Cart Part No 3H.181.05.0.00 , Fuel Pipe Return M12x1.5 Male Plug & M16x1.5 Union Nut 900Mm Long Cart Part No 3H.181.13.0.00 , Fuel Pipe Return: M12 Male Plug 14 Union Nut: 400Mm Long Cart Part No 3H.183.16.0.00 , Fuel Pipe Return With M12 Male Plug14 Union Nut250mm Long Cart Part No 3H.183.17.0.00 , Fuel Pipe Return With M14 X 15 Male Plug & ,M14 X 15 Union Nut 250Mm Cart Part No 3H.183.21.0.00 , Fuel Pipe Return With M14 X 1 5 Male Plugm14 X 1 5 Union Nut400mm Long Cart Part No 3H.183.24.0.00 , Fuel Return Pipe M14x1 5 Male Plugm16x1 5 Union Nut Cart Part No 3H.183.25.0.Pr , Fuel Inlet Pipe Metailic Pre-Filter To Tank Cart Part No 3H.183.27.0.Pr , Fuel Pipe Return With M14 Male Plug M16 Union Nut Cart Part No 3H.183.33.0.Pr , Fuel Return Pipem22x1 5 Male Plug M22x1 5 Union Nut Cart Part No 3H.183.37.0.Pr , Air Inlet Manifold For Shanti (Aluminium) Cart Part No 3H.185.01.0.00 , Rocker Cover Cart Part No 3H.190.10.0.00 , Rocker Cover Cart Part No 3H.190.30.0.00 , Fuel Filter Mounting Bracket Spin On Type Cart Part No 3H.191.01.0.00 , Header For L.O. Cooler & Filter S/F Water Jacket Heating Cart Part No 3H.192.01.0.00 , Battery Cable 35Sqmm Cart Part No 3H.208.40.0.Pr , Cold Start Kit Assembly For L3 Level Application 12V System3r Cart Part No 3H.211.70.0.Pr , Hose-Thermostat To Radiator Cart Part No 3H.217.04.0.00 , Drain Pipe For Lub Oil Sump For 6R1080t,6R1080tawith Length 640Mm Cart Part No 3H.219.03.0.00 , Dial Type Mechanical Fuel Level Gauge (105Mm) Cart Part No 3H.219.05.0.00 , Expansion Bellow: 3R Vave Genset 290Mm Cart Part No 3H.223.05.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 3H.241.03.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 3H.241.04.0.00 , Injector Leak Off Pipe 3R1190 Cpcb4 Cart Part No 3H.246.11.0.Pr , Fuel Pipe I/L - M16x1.5 Union Cart Part No 3H.280.01.0.00 , Pipe (From Radiator Outlet To Water Pump Inlet) Cart Part No 3H.282.01.0.00 , Hose From Water Pump In To Radiator Out Cart Part No 3H.282.04.0.00 , Pipefrom Radiator Outlet To Water Pump Inlet Cart Part No 3H.282.05.0.00 , Spout For Fuel Filling Cart Part No 3H.283.05.0.00 , Fuel Pipe (Feed Pump To Filter) Cart Part No 3H.289.03.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 3H.289.07.0.00 , Fuel Pipe Feed Pump To Tank Unit Cart Part No 3H.289.14.0.00 , Fuel Pipe (Feed Pump To Tank Unit) Cart Part No 3H.289.15.0.00 , Fuel Pipefeed Pump To Tank Unit Cart Part No 3H.289.21.0.Pr , Hose: Thermostat To Radiator Cart Part No 3H.291.01.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 3H.291.02.0.00 , Bracket For Stay Cart Part No 3H.291.03.0.00 , Stay For Radiator Cart Part No 3H.291.04.0.00 , Hose: Make Up Connection Cart Part No 3H.291.07.0.00 , Hose: Make Up Connection Cart Part No 3H.291.09.0.00 , Aluminium Radiator: 3R Cart Part No 3H.291.10.0.00 , Hose From Water Pump In To Radiator Outlet Cart Part No 3H.291.101.0.Pr , Hosethermostat To Radiator Cart Part No 3H.291.102.0.Pr , Hose: Radiator To Pump Inlet Cart Part No 3H.291.18.0.00 , Breather Hose Cart Part No 3H.291.29.0.00 , Hose For Make Up Connection Cart Part No 3H.291.32.0.00 , Hosethermostat To Radiator Cart Part No 3H.291.37.0.Pr , Pipe - Thermostat To Rad In. Cart Part No 3H.291.41.0.00 , Hose: Thermostat Outlet To Radiator In Cart Part No 3H.291.42.0.00 , Hose- Metallic Pipe To Radiator In. Cart Part No 3H.291.43.0.00 , Hose - Radiator To Pump In Pipe Cart Part No 3H.291.44.0.00 , Hose: Make Up Connection Cart Part No 3H.291.46.0.00 , Pipe Thermostat To Radiator In Cart Part No 3H.291.47.0.Pr , Pipe From Radiator To Pump Inlet Cart Part No 3H.291.48.0.Pr , Aluminium Radiator Assly: 3R1040 Cart Part No 3H.291.90.0.00 , Aluminium Radiator Assembly For 3R1040 Cpcb Engines Cart Part No 3H.291.94.0.00 , Aluminium Radiator Assembly Cart Part No 3H.291.95.0.Pr , Aluminium Radiator Assembly Cart Part No 3H.291.96.0.Pr , Leak Off Pipe Cart Part No 3H.292.01.0.00 , Leak Off Pipe Cart Part No 3H.292.02.0.00 , Clamp Cart Part No 3H.292.05.0.Pr , Crankshaft Assembly Cart Part No 3H.299.10.0.00 , Crankshaft Assly Without Gear Cart Part No 3H.299.20.0.00 , Wet Pm Kit (W/O Oil) 3H.3001, 3H.3012 - 3R1040 Cart Part No 3H.300.1.0.Sp , Bracket For Fuel Filter Mounting Cart Part No 3H.301.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 3H.301.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 3H.301.03.0.00 , Charging Alternator 12V, 35A Cart Part No 3H.315.01.0.00 , Charging Alternator 35A13 5V Regulator With Battery Sensing Cart Part No 3H.315.03.0.Pr , Stud Coupler 70Mm Cart Part No 3H.328.11.0.00 , Lube Oil Drain H& Pump Assembly Cart Part No 3H.345.10.0.00 , 125A, 4Pole Mccb, Model: Lv516312, Mak Cart Part No 3H.352.14.0.Pr , Rad Water Fill Cap With Rubber Seal For Canopy Cart Part No 3H.408.31.0.00 , Ceramic Wool 64 Density Cart Part No 3H.408.54.0.00 , Flame-Proof High Density Foam 70 Density, Cart Part No 3H.408.88.0.00 , Ss Lh Hinge For Canopy Cart Part No 3H.408.90.0.00 , Ss Rh Hinge For Canopy Cart Part No 3H.408.91.0.00 , Hose: Air Cleaner Cart Part No 3H.415.06.0.00 , Pvc Pipe For Air Cleaner Cart Part No 3H.415.07.0.00 , Air Cleaner Assly: 4.5M3 Cart Part No 3H.415.10.0.00 , Hose For Air Cleaner With Restriction Indicator Port Cart Part No 3H.415.22.0.00 , Hose For Pvc Pipe Cart Part No 3H.415.23.0.00 , Pvc Pipe For Air Cleaner Cart Part No 3H.415.24.0.00 , Air Cleaner Assembly Cart Part No 3H.415.25.0.00 , Primary Element Cart Part No 3H.415.46.0.00 , Avm Cylindricalh 30 X Dia 30 X M8radiator 40 45 Sh Cart Part No 3H.432.03.0.Pr , Control Panel Schematic For 45Kva3ph With Kg645 Ip A Cart Part No 3H.465.40.0.Pr , Control Panel Schematic For 45Kva 3Ph 3Rta With Kg645 Ip B Cart Part No 3H.465.50.0.Pr , Control Panel Schematic For 45Kva3ph With Kg640 Ip A Cart Part No 3H.465.70.0.Pr , Control Panel 25 30 Kva For 3Rt 3Ph With Kg640ip B Cart Part No 3H.470.80.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 3H.488.02.0.Pr , Fuel Pipe (Pre Filter To Tank Unit) Cart Part No 3H.488.03.0.Pr , Fuel Pipe Return With M14 X 1.5 Male Plug & ,M14 X 1.5 Union Nut Cart Part No 3H.488.04.0.Pr , Air Cleaner Hose Cart Part No 3H.488.06.0.Pr , Hose For Pvc Pipe Cart Part No 3H.488.07.0.Pr , Exhaust Pipe (Doc Outlet To Bellow) Cart Part No 3H.488.12.0.Pr , U Clamp For Doc Cart Part No 3H.488.14.0.Pr , Clamping Plate For Doc Cart Part No 3H.488.16.0.Pr , Fuel Pipepre Filter To Tank Unit Cart Part No 3H.488.33.0.Pr , Air Cleaner Hose To Turbo Cart Part No 3H.488.34.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 3H.488.43.0.Pr , Hosethermostat To Radiator Cart Part No 3H.488.44.0.Pr , Crankcase Assembly Cart Part No 3H.501.20.0.00 , Special Banjo Bolt Assemblyfor Oil Spray Nozzle Cart Part No 3H.501.30.0.00 , Oil Spray Nozzle Assly Cart Part No 3H.501.40.0.00 , Inlet Manifold Cart Part No 3H.502.01.0.00 , Inlet Manifold Cart Part No 3H.502.03.0.00 , Exhaust Manifold Cart Part No 3H.503.01.0.00 , Hose: Turbocharger Cart Part No 3H.504.03.0.00 , Air Pipe Cart Part No 3H.504.05.0.00 , Lube Oil Supply Pipe Cart Part No 3H.505.01.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 3H.505.02.0.00 , Air Pipe (Turbo Side) Cart Part No 3H.506.02.0.00 , Bracketfor Air Pipe Cart Part No 3H.506.05.0.00 , Joint For Air Pipe Cart Part No 3H.506.06.0.00 , Air Pipe (Cac Side) Cart Part No 3H.506.08.0.00 , Air Pipe (Cac To Inlet Manifold) Cart Part No 3H.506.11.0.00 , Air Pipe (Turbo Side) Cart Part No 3H.506.17.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No 3H.506.18.0.00 , Cac Hosecold Side Cart Part No 3H.506.19.0.00 , Exhaust Diffuser Cart Part No 3H.518.01.0.00 , Bracket For Diffuser Cart Part No 3H.518.02.0.00 , Valve Rocker Assembly Cart Part No 3H.519.20.0.00 , Adaptor On Inlet Manifold Cart Part No 3H.520.01.0.00 , Cps Module Cart Part No 3H.577.01.0.00 , 1 Pin Connectorf350 Seriesmssl Tt Amp Uvs Cart Part No 3H.577.05.0.Sp , Engine Wiring Harness Assembly Cart Part No 3H.577.20.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.577.80.0.00 , Cold Start Wiring Harness Sf Flange Heater Cart Part No 3H.578.100.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.578.40.0.00 , Engine Wiring Harness With Cps 4-20Ma Gems Sensor Cart Part No 3H.578.50.0.00 , Engine Wiring Harness With Cps 3R 45 Kva Cart Part No 3H.578.60.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.579.20.0.00 , Engine Wiring Harness Sf 3R Engine Cart Part No 3H.580.10.0.00 , Engine Wiring Harness 30Kva 3R Cart Part No 3H.580.20.0.Pr , Temp Sensor Pigtail Cart Part No 3H.580.40.0.Pr , Selector Switch 3Way With Off5 Pole Cart Part No 3H.581.56.0.Pr , Selector Switch 6A 3Way With Off4 Pole Cart Part No 3H.581.57.0.00 , Selector Switch 6A 2Way With Off2 Pole Cart Part No 3H.581.58.0.00 , Engine Wiring Harness With Cps 3R Sf Kg934 Cart Part No 3H.584.10.0.00 , Engine Wiring Harness For 3Rt 30Kva Emerald Cart Part No 3H.584.40.0.Pr , Mcb, 2Pole, 2 Amps Cart Part No 3H.5960.33.0.00 , Engine Wiring Harness For 3Rta 30Kva Crdi Cpcb4engine Cart Part No 3H.6257.40.0.Pr , Exhaust Doc Pipe Benddoc Out To Bellow In Cart Part No 3H.768.03.0.Pr , Silencer Assembly Cart Part No 3H.792.40.0.Pr , Terminal Block Assembly- 25-40 Kva 1 Phase Cart Part No 3H.816.01.0.Asp , Sae 3,De Brkt- Prot. Screen Asly - Kg32 Cart Part No 3H.816.03.0.Asp , Excitor Rotor With Rra Kg32 M L H 55 6Pkva Rating30 401Ph Cart Part No 3H.816.05.0.Asp , Koel Green Alternatorkg30 S T Framem Ecp28a Vl 4Sae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.816.23.0.Pr , Wet Pm Kit (W/O Oil) For 3H.8322 Cart Part No 3H.832.2.0.Sp , Relay Board-12Vdc Therm Elect Cart Part No 3H.853.01.0.00 , 12V Control Panel Assembly For Ff Pumpset With Male Connector Cart Part No 3H.853.10.0.00 , Control Panel 24V Fighting Cart Part No 3H.854.10.0.00 , Mcb: 32A Sp Cart Part No 3H.864.04.0.00 , Mcb Single Pole 6Amp - A9n1p06c Cart Part No 3H.864.09.0.00 , Amf Panel Dwg Of 3R 30Kva 3Ph For Reliance Infratel Cart Part No 3H.864.40.0.Pr , Glass Fuse 20 Mm Length 4 Amp Cart Part No 3H.870.08.0.00 , Battery Charger : 4A 24 Vdc Cart Part No 3H.870.15.0.00 , Mcb 50A 3Pole Cart Part No 3H.894.07.0.00 , Koel Green Alternatorkg 25 S T Framel Kg 42 3 Bsae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.901.01.0.Pr , Koel Green Alternatorkg 25 S S Framel Kg 42 3 Fsae 3 11 5 230V50 Hz0 8 Pf Cart Part No 3H.901.02.0.Pr , Koel Green Alternatorkg35 S S Framel Kg 42 3 Jsae 3 11 5 230V50 Hz0 8 Pf Cart Part No 3H.901.04.0.Pr , Koel Green Alternatorkg35 S T Framel Kg 42 3 Esae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.901.05.0.Pr , Clip 25 Dia For Flexible Pipe Cart Part No 3H.905.02.0.00 , Clip 20 Dia For Flexible Pipe Cart Part No 3H.905.04.0.00 , Rubber Sleeve For Tempswitch Cart Part No 3H.905.05.0.00 , Tie Wrap 200 Mm Length Cart Part No 3H.905.07.0.00 , Rubber Sleeve 16 Dia Cart Part No 3H.905.15.0.00 , Rubber Sleeve 27 Dia Cart Part No 3H.905.16.0.00 , P-Clip Cart Part No 3H.905.18.0.Pr , Wiring Harness With Connector For Switches Cart Part No 3H.913.10.0.00 , Wiring Harness For Ff Pumpset Allication Cart Part No 3H.922.10.0.00 , Hosethermostat To Radiator Cart Part No 3H.9457.25.0.Pr , Hose Radiator To Pump In Pipe Cart Part No 3H.9457.27.0.Pr , Gear Casining Cart Part No 3H.962.01.0.00 , Camshaft Assly Cart Part No 3H.968.20.0.Pr , Cylinder Head Gasket Cart Part No 3H.969.02.0.Pr , Cyl Head With Valve Guide Valve Seat Insert Cart Part No 3H.969.20.0.Pr , Cylinder Head Assembly Cart Part No 3H.971.30.0.00 , Bracket For Fuel Filter Cart Part No 3H.972.02.0.00 , Kit For Replacement Of Interface Card From 3H.982.31 And 3H.982.32 To 3H.989.12 Cart Part No 3H.989.11.0.Sp , Dc Interface Card Cart Part No 3H.989.12.0.00 , Engine Wiring Harness Cart Part No 3H.990.10.0.Pr , Connecting Rod Assyw O Bearing Cart Part No 3H.991.10.0.00 , Leak Off Pipe Cpcb, M12u Cart Part No 3H.992.01.0.Pr , Bracket For Doc Mounting Cart Part No 3H.995.01.0.Pr , Doc_3R1190_Na Cart Part No 3H.995.04.0.Pr , Conrod Bearing Set For 3H 9801Engine Cart Part No 3H.999.08.0.Sp , Set Of Joints Cart Part No 3H.999.10.0.Sp , Wet Pm Kit (W/O Oil) For 3H.8422,3H.8422.Pb,3H.8423,3H.8407,3H.8408,3H.8409,3H.8411,3H.84 Cart Part No 3H.999.15.0.Sp , Wet Pm Kit (W/O Oil ) For 3H.8902 Cart Part No 3H.999.19.0.Sp , Wet Pm Kit (W/O Oil) For 3H.3025, 3H.3030, 3H.3031, 3H.8301,3H.8403, 3H.8503, 3H.8506, 3H.90 Cart Part No 3H.999.20.0.Sp , Wet Pm Kit (W/O Oil ) For 3H.8951 Cart Part No 3H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 3H.3017 - 3R1040 ( Cpcb ) Cart Part No 3H.999.84.0.Sp , Crankshaft Pulley Cart Part No 3H.M001.01.0.00 , Hose Thermstat To He Inlet Cart Part No 3H.M412.03.0.00 , Hose Pipe: Inlet Manifold Cart Part No 40.002.06.0.00 , Hose: Water Outlet Manifold Cart Part No 40.003.02.0.00 , Spacer For Fan (15 Mm) Cart Part No 40.054.03.0.00 , V Belt: B48 1262 Long Cart Part No 40.123.01.0.00 , O Ring: Cyinder Liner -21507 Cart Part No 42.003.02.0.00 , Cyl Liner Assembly Cart Part No 42.003.20.0.00 , Sealing Bush: Cyl Hd Stud Cart Part No 42.004.19.0.00 , Valve Seat Insert Exh Cart Part No 42.004.21.0.00 , O Ring: P R Ferrule 2.7X18 - 21509 Cart Part No 42.004.22.0.00 , Jointcyl Liner To Head 0 40Mm Thick Cart Part No 42.004.23.0.00 , Ferrule Tube Cart Part No 42.004.26.0.00 , Sealing Ring Cart Part No 42.004.28.0.00 , Valve Pair Cart Part No 42.004.70.0.00 , Sleeve: Nozzle Holder Cart Part No 42.005.05.0.00 , Piston Pin Cart Part No 42.008.02.0.00 , Piston Ring Set Std Rb00 Cart Part No 42.008.72.0.00 , Joint: Cyl Head To Exh Manifold Cart Part No 42.014.02.0.00 , Joint: Cyl Head To Air Inlet Manifold Cart Part No 42.014.03.0.00 , Exhaust Silencer Cart Part No 42.066.02.0.00 , Starting H&Le Cart Part No 42.091.30.0.00 , Adaptor: 23Mm Cart Part No 42.102.01.0.00 , Sump Drain Pipe: 700Mm Benjo On Both Side Cart Part No 42.107.01.0.00 , Water Separator Cart Part No 43.075.10.0.00 , Mud Collector - Filter Cart Part No 43.075.20.0.00 , Anti Vibration Mounts Cart Part No 44.035.05.0.00 , Leak Off Pipe Cart Part No 45.052.01.0.00 , Hose Cart Part No 45.106.05.0.00 , Cyl Liner Assembly Cart Part No 46.005.10.0.00 , Push Rod Cart Part No 46.008.20.0.00 , Set Of Jointsrb22 Rb00 Cart Part No 46.039.10.0.00 , Set Of Copper Washer Cart Part No 46.039.30.0.00 , Flexible Pipe: 1 Mt Long Cart Part No 46.048.01.0.00 , Electric Water Temp Gauge 12V Cart Part No 46.065.02.0.00 , Electric Water Temp Gauge 40-120 Degc24v Cart Part No 46.066.02.0.00 , Collet Pair Cart Part No 46.072.04.0.00 , Joint: Cyl Head 1.00 Cart Part No 46.072.22.0.00 , Steel Joint:Cyl Head 1.2Mm Cart Part No 46.072.23.0.00 , Steel Joint:Cyl Head 1.4Mm Cart Part No 46.072.24.0.00 , Steel Joint:Cyl Head 1.6Mm Cart Part No 46.072.25.0.00 , Joint: Cyl Head 1.1Mm Th Cart Part No 46.072.26.0.00 , Cyl Head Joint:1.3Mm Cart Part No 46.072.27.0.00 , Steel Joint:Cyl Head 1.5Mm Cart Part No 46.072.28.0.00 , Lube Oil Temp Gauge Elect:40-150/160 D Cart Part No 46.084.01.0.00 , Lube Oil Temp Gauge Ele:40-150/160 D Cart Part No 46.085.01.0.00 , Sensor Unit: Elec Temp Gauge Cart Part No 46.085.02.0.00 , Adaptor For Exhaust Silencer Cart Part No 46.148.01.0.00 , Elec Hour Meter 12V Cart Part No 46.177.01.0.00 , Electronic Hour Meterr 24V Cart Part No 46.178.01.0.00 , Magnetic Pickup Cart Part No 46.179.05.0.00 , Valve Pair Cart Part No 46.188.70.0.00 , Lube Oil Press Gauge 0-10 Kg/Sqcm Cart Part No 46.244.01.0.00 , Electrical Lube Oil Press Gauge 0-10Bar Cart Part No 46.250.01.0.00 , Lube Oil Press Gauge Electrical:0-10 Bar 24V Cart Part No 46.251.01.0.00 , Rubber Sleeve 38X10 For Pr Gauge Sensor Cart Part No 46.252.02.0.00 , Lube Oil Pressure Sensor With Switch Three Point Dual Wiper Type Cart Part No 46.252.05.0.00 , Wiring Harness For Elec Pr Gauge Sendor Cart Part No 46.252.20.0.00 , Wiring Harness For Lube Oil Pressure Cart Part No 46.252.40.0.00 , Hour Meter Digital Cart Part No 46.253.02.0.Pr , Silensor Clamp Cart Part No 46.256.05.0.00 , Rubber Block 0.12 Rb Coupling Cart Part No 46.349.04.0.00 , Inner Member0 12 Rb Coupling Cart Part No 46.349.05.0.00 , Coupling: 0.12 Rb Cart Part No 46.349.10.9.00 , Set Of Copper Washer Cart Part No 46.353.08.0.00 , Expansion Bellow Assly: 2.5 Cart Part No 46.357.10.0.00 , Sleeve For Exhaust Silencer 55 2 Dia Cart Part No 46.367.03.0.00 , Water Pump With Spindle Brg Cart Part No 46.388.03.0.00 , Alternator: 12V 35A Cart Part No 46.390.01.0.00 , Push Rod Kit Cart Part No 46.999.01.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 47.002.02.0.00 , Joint Bet Cr Case & Block (0.80 Mm Thick Cart Part No 47.014.02.0.00 , Joint: Cyl Block 0.80 Mm Thk Cart Part No 47.014.08.0.00 , Copper Shim Cart Part No 47.014.09.0.00 , Copper Shim: 0.50 Mm Cart Part No 47.014.11.0.00 , Thermostat Cover-Horizontal Outlet Pointing Towards Rights Side Viewing Tow Cart Part No 47.025.03.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 47.027.01.0.00 , Joint: Brg Housing Water Pump Cart Part No 47.033.02.0.00 , Lube Oil Filter Assly Cart Part No 47.035.10.0.00 , Set Of Joints Cart Part No 47.045.10.0.00 , Set Of O Rings: Rb33-Rb00 Cart Part No 47.045.20.0.00 , Set Of Copper Washer Cart Part No 47.045.30.0.00 , Spacer For Fan Cart Part No 47.051.01.0.00 , Set Of Joints Cart Part No 47.094.10.0.00 , Set Of O Ringsfor Swaraj 855 Tractor Cart Part No 47.094.20.0.00 , Set Of Copper Washer Cart Part No 47.094.30.0.00 , Primary Filter Element Cart Part No 47.113.04.0.00 , Safety Filter Element Cart Part No 47.113.05.0.00 , Restriction Indicator -20Wg Cart Part No 47.113.15.0.00 , Restriction Indicator 47.113.15.0. Wit Cart Part No 47.113.18.0.Pr , Radiator Fan: Rr Engine 15 Pusher Cart Part No 47.127.01.0.00 , Rubber Bush: Top Cart Part No 47.204.04.0.00 , Joint For Cooler Cover Plate Cart Part No 47.212.04.0.00 , Sealed Water Saparator Assembly Cart Part No 47.277.10.0.00 , Water Separator Cart Part No 47.278.01.0.00 , Water Separator Cart Part No 47.278.05.0.00 , Gear Casing Gasket Cart Part No 47.297.04.0.00 , Wet Pm Kit (W/O Oil) For 47.3001 - Rb33 Cart Part No 47.300.01.0.Sp , Wet Pm Kit (W/O Oil) For 46.3001,46.3004,46.3006,46.4004 - Rb22 Cart Part No 47.300.1.0.Sp , Wet Pm Kit (W/O Oil) For 47.3013,47.3027,47.3037,47.9017,47.9027 - Rb33 Cart Part No 47.301.3.0.Sp , V Belt Cogged (Bx-48) Cart Part No 47.305.01.0.00 , Bearing For Hydraulic Gear Cart Part No 47.307.05.0.00 , Drive Shaft Assembly Cart Part No 47.307.20.0.00 , V Belt Bx52 Cog Cart Part No 47.329.02.0.00 , Cap Assembly Cart Part No 47.383.30.0.00 , Hose: Water Pipe To Adaptor Cart Part No 47.387.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 47.387.03.0.00 , Hose: Radiator To Thermostat Cart Part No 47.387.07.0.00 , Hose (Thermostat To Radiator) Cart Part No 47.491.01.0.00 , Hose: Radiator To Pump Inlet Cart Part No 47.491.04.0.00 , Make-Up Hose Cart Part No 47.491.05.0.00 , Makeup Hose: Rb33 Cart Part No 47.491.09.0.00 , Aluminium Radiator: Rb33 Cart Part No 47.491.90.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 47.492.01.0.00 , Piston Assembly Cart Part No 47.507.20.0.00 , Expansion Bellow Cart Part No 47.512.10.0.00 , Joint: Gear Casing Cart Part No 47.515.02.0.00 , Leak Off Pipe Sub Assly Cart Part No 47.531.10.0.00 , Piston Assembly Cart Part No 47.533.10.0.00 , Piston Ring Set Cart Part No 47.533.30.0.00 , Joint For Rocker Cover Cart Part No 47.541.02.0.00 , Stepless Ear Clamp Cart Part No 47.542.02.0.00 , 50 Am. Terminal(Male) Type-280075-2 Cart Part No 47.569.12.0.00 , Oetiker Clamp Id361 Cart Part No 47.601.01.0.00 , Oetiker Clamp With 565 Id Cart Part No 47.601.08.0.00 , Push Rod Kit Cart Part No 47.990.01.0.00 , Wet Pm Kit (W/O Oil) For 47.1523 - Rb33 Cart Part No 47.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 47.3024 - Rb33 Cart Part No 47.999.12.0.Sp , Wet Pm Kit (W/O Oil) For 47.3021 - Rb33 Sr Ii Cart Part No 47.999.27.0.Sp , Wet Pm Kit (W/O Oil) For 38.3001- Rb33 Sr Ii Cart Part No 47.999.34.0.Sp , Wet Pm Kit (W/O Oil) For 47.3008, 47.3012 - Rb33 Plus Cart Part No 47.999.62.0.Sp , Hose: Thermostat To Radiator 160Lg Cart Part No 48.019.02.0.00 , Hose Cart Part No 48.019.06.0.00 , Adaptor : Water Pump Cart Part No 48.019.07.0.00 , Joint: Water Pump Adopter Cart Part No 48.019.08.0.00 , Clamp For Raised Dip Stick Guide Cart Part No 48.032.07.0.00 , Set Of Jointsrb44 Rb00 Cart Part No 48.039.10.0.00 , Set Of Copper Washer Cart Part No 48.039.30.0.00 , Dowel Bolt: Alternator -M10x130lg Cart Part No 48.067.03.0.00 , Bush For Alternator 32Mm Cart Part No 48.067.04.0.00 , Leak Off Pipe 1000 Mm Long Cart Part No 48.112.01.0.00 , Plate For Fuel Filter Cart Part No 48.113.01.0.00 , Overhaul Kit Rb44 Jcb Cart Part No 48.115.30.0.00 , O Ring Cart Part No 48.117.03.0.00 , Fuel Filter Element Pre Cart Part No 48.117.04.0.00 , Fuel Filter Element Micro Cart Part No 48.117.05.0.00 , Fuel Filter 1.1 L Twin Bowl Cart Part No 48.117.10.0.00 , L.O.P.G.Pipe - 2 Mtr Long Cart Part No 48.121.01.0.00 , Sealing Ring: Push Rod Tube Cart Part No 48.122.01.0.00 , Fuel Pipe Cart Part No 48.129.01.0.00 , Outer Element Cart Part No 48.145.02.0.00 , Inner Element Cart Part No 48.145.03.0.00 , Air Cleaner Assly: Dry Type Cart Part No 48.145.10.0.00 , Sealing Ring For Water Ferrule Cart Part No 48.155.04.0.00 , Set Of Joint Cart Part No 48.156.10.0.00 , Set Of O Rings Cart Part No 48.156.20.0.00 , Set Of Copper Washer Cart Part No 48.156.30.0.00 , Joint: Bearing Housing Cart Part No 48.173.08.0.00 , Fuel Pipe-9.5,14X14b,450R Cart Part No 48.188.01.0.00 , Radiator Fan 17Dia-Pusher Cart Part No 48.212.01.0.00 , Anti Vibrn Mtg: Bottom Radiator Cart Part No 48.213.08.0.00 , Radiator Cap: 7Psi Sealed Cart Part No 48.213.15.0.00 , Thermostat Bypass Hose Cart Part No 48.214.04.0.00 , Rubber Hose Cart Part No 48.215.04.0.00 , Pre Cleaner Assly Cart Part No 48.215.10.0.00 , Flex Pipe -Engine To Cooler Cart Part No 48.231.03.0.00 , Plug For Dip Stick Hole Cart Part No 48.288.02.0.00 , Jupiter Worm Drive Clamp,Type 603,65Mm Dia(S/F 65Mm Hose O.D.) Cart Part No 48.305.06.0.00 , Worm Drive Hose Clamp 80Mm Cart Part No 48.305.07.0.00 , Hose Clamp: 110Mm Dia Cart Part No 48.305.08.0.00 , Silencer Assly Cart Part No 48.318.10.0.00 , Sucker Fan 494 Dia Metallic Cart Part No 48.338.02.0.00 , Holder For Inner Cable Cart Part No 48.340.02.0.00 , Fuel Pipe: M14xm14-1800 Length Cart Part No 48.406.01.0.00 , Spacer For Support Bracket Cart Part No 48.414.01.0.00 , Lube Oil Supply Hose: Fip Cart Part No 48.417.01.0.00 , Alternator: 24V 40A Cart Part No 48.436.01.0.00 , Actuator Cart Part No 48.503.01.0.00 , Fuel Filter Kit 1.1 Ltr Cart Part No 48.999.20.0.00 , Set Of Joints Cart Part No 49.079.10.0.00 , Set Of O Rings: Rb66-Rb00 Cart Part No 49.079.20.0.00 , Set Of Copper Washer Cart Part No 49.079.30.0.00 , Radiator Fan: 494 Dia Pusher Cart Part No 49.080.01.0.00 , Worm Drive Hose Clip Cart Part No 49.097.01.0.00 , Worm Drive Hose Clip Cart Part No 49.097.07.0.00 , Hose Clip Size No 1 28X30 Cart Part No 49.097.08.0.00 , Nut: Ss M8 Cart Part No 49.106.02.0.00 , Exhaust Silencer Cart Part No 49.114.01.0.00 , O Ring: Element Header Cart Part No 49.117.06.0.00 , Fan: 20 Pusher Cart Part No 49.119.01.0.00 , Joint: Turbo Inlet Cart Part No 49.120.04.0.00 , Joint: Inlet Pipe Cart Part No 49.121.03.0.00 , Joint: Drain Pipe Cart Part No 49.121.05.0.00 , Off/On/Start Switch 1160A Cart Part No 49.135.03.0.00 , Low Oil Pres Switch 1.7Kg/Cmsq Cart Part No 49.156.01.0.00 , Bracket For Rpm Meter (Fitted On Body) Cart Part No 49.162.01.0.00 , V Belt: Bx51 Raw Edge Cogged Cart Part No 49.202.01.0.00 , Air Inlet Cap Cart Part No 49.403.03.0.00 , Coupling 0.24 Rb Cart Part No 49.438.10.9.00 , Rubber Block 0.2 Rb Coupling Cart Part No 49.462.04.0.00 , Coupling: 0.20 Rb Cart Part No 49.462.10.9.00 , Hose(For Drain Pipe) Cart Part No 49.472.08.0.00 , Piston Assembly Cart Part No 49.480.10.0.00 , Piston Ring Set (3Ring) Cart Part No 49.480.30.0.00 , Relay For Stop Solenoid Cart Part No 49.626.05.0.00 , Engine Safety Unit: Krb101 Cart Part No 49.902.02.0.00 , Blanking Plate For Cam Bore Cart Part No 4H.001.03.0.00 , Sealing Cap Cart Part No 4H.001.05.0.00 , Hollow Dowel (16 Dia) Cart Part No 4H.001.13.0.00 , Joint: Cam Bore Blanking Plate Cart Part No 4H.001.14.0.00 , Precoated Plug Cart Part No 4H.001.22.0.00 , Monoblock Ccase W/O Bearing Cart Part No 4H.001.70.0.00 , Crankshaft Gear Cart Part No 4H.002.01.0.00 , Crankshaft Gear Assly Cart Part No 4H.002.20.0.00 , Crankshaft Assly. With Gear Cart Part No 4H.002.60.0.00 , Thrust Washer - Cam Shaft Cart Part No 4H.003.02.0.00 , Camshaft Sub Assly Cart Part No 4H.003.20.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.003.70.0.00 , Camshaft Gear Assembly Cart Part No 4H.003.80.0.00 , Lo Supply Hose Fip M10 Banjo X 235 Cart Part No 4H.006.01.0.00 , Delivery Valve Cart Part No 4H.006.04.0.00 , Fuel Pump: 9 Mm Lift Vsc Cart Part No 4H.006.10.0.00 , Lub Oil Supply Pipe, Crankcase To Fuel Pump, 210 L Cart Part No 4H.006.13.0.00 , Valve Guide Cart Part No 4H.007.02.0.00 , Valve Seat Insert-Inlet Cart Part No 4H.007.03.0.00 , Valve Seat Insert-Exhaust Cart Part No 4H.007.04.0.00 , Bolt For Cylinder Head. Cart Part No 4H.007.07.0.00 , Button For Injector Yoke Cart Part No 4H.007.08.0.00 , Gasket: Cylinder Head 1.10 Thk Cart Part No 4H.007.11.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 4H.007.24.0.00 , Valve Seat Insertinlet Semi Finish Cart Part No 4H.007.39.9.00 , Valve Pair Inlet & Exhaust Cart Part No 4H.007.40.0.00 , Cylinder Head Reconditioning Kit 4R1040 Engines (Pg & Indl Bsii) Cart Part No 4H.007.55.0.00 , Valve Rocker Assly Cart Part No 4H.008.10.0.00 , Rocker Shaft Sub Assly Cart Part No 4H.008.20.0.00 , Rocker Cover Joint Metalic Cart Part No 4H.009.12.0.00 , Gasket (For Rocker Cover) Cart Part No 4H.009.15.0.00 , Leak Off Pipe Assly Cart Part No 4H.010.23.0.00 , Leak Off Pipe Assembly Cart Part No 4H.010.29.0.00 , Auto Timer Cart Part No 4H.012.01.0.00 , Fuel Pump Gear Cart Part No 4H.012.02.0.00 , Bolt Assly.(Autotimer) Cart Part No 4H.012.20.0.00 , Suction Tube Assly Cart Part No 4H.015.10.0.00 , Hydraulic Pump Gear Cart Part No 4H.016.01.0.00 , Crank Pulley: Finish Cart Part No 4H.019.01.0.00 , Mud Slinger Cart Part No 4H.019.93.0.00 , Spacer For Mud Slinger Cart Part No 4H.019.94.0.00 , Spacer For Fan Ejcb 3Dx Cart Part No 4H.020.02.0.00 , Spacer: Fan Cart Part No 4H.020.03.0.00 , Radiator Fan: Ejcb Cart Part No 4H.020.91.0.00 , Joint: Delivery Volute Cart Part No 4H.021.03.0.00 , Water Pump Pulley: 120Pcd Spa Section Cart Part No 4H.021.08.0.00 , Water Pump Assly 345 Crs Cart Part No 4H.021.20.0.00 , Water Pump Assly Wo Del Vol 345Crs Cart Part No 4H.021.30.0.00 , Joint: Water Outlet Manifold Cart Part No 4H.022.11.0.00 , Thermostat Bypass Hose Cart Part No 4H.023.02.0.00 , Bypass Hose: 58Mm Long Cart Part No 4H.023.03.0.00 , Thermostat Bypass Hose Cart Part No 4H.023.06.0.Pr , Vacuator Valve Cart Part No 4H.024.03.0.00 , Primary Filter Element Cart Part No 4H.024.12.0.00 , Safety Filter Element Cart Part No 4H.024.13.0.00 , Air Cleaner Assly Cart Part No 4H.024.70.0.00 , Set Of High Press Pipe: 530X1.5 Id Cart Part No 4H.025.10.0.00 , Oil Filling Body Sub Assly Cart Part No 4H.027.10.0.00 , Joint: Oil Filling Body Cart Part No 4H.027.11.0.00 , Exhaust Manifold (End Opening) Cart Part No 4H.028.01.0.00 , Hose: Dry Type Air Cleaner Cart Part No 4H.029.02.0.00 , T Bolt Clamp, Klipco Tb 88 /Jupitor ( 92 To 100 Dia ) Cart Part No 4H.029.05.0.00 , T Bolt Clamp Tb78: 84 Cart Part No 4H.029.06.0.00 , Air Inlet Manifold Cart Part No 4H.030.01.0.00 , Mettalic Joint: Inlet Manifold Cart Part No 4H.030.06.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.030.11.0.00 , Bracket For Fuel Filter Cart Part No 4H.031.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.031.04.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 4H.031.05.0.00 , Clamp Cart Part No 4H.031.06.0.00 , Rubber Sleeve Cart Part No 4H.031.07.0.00 , Clamp Assembly Without Rubber Sleeve Cart Part No 4H.031.30.0.00 , Lifting Hook Cart Part No 4H.033.01.0.00 , Engine Lifting Hook Cart Part No 4H.033.03.0.00 , Dipstick Assly Cart Part No 4H.034.10.0.00 , Gasket: Exh Manifold Cart Part No 4H.035.02.0.00 , Gasket: Exh Adaptor S.S. Cart Part No 4H.035.03.0.00 , Plastic Cover For Exhaust Manifold Opening Cart Part No 4H.035.05.0.00 , Exhaust Mfold Ge Top Open Cart Part No 4H.035.07.0.00 , Adaptor: Exhaust Silencer Cart Part No 4H.036.01.0.00 , Flywheel Housing Cart Part No 4H.038.01.0.00 , Flange: Starter 13- 6Mm Eff Cart Part No 4H.038.02.0.00 , Blanking Plate For Flywheel Housing Cart Part No 4H.038.04.0.00 , Water Inlet Connection 38 Core Cart Part No 4H.039.01.0.00 , Joint: W.I Conn & Therm Hsg Cart Part No 4H.039.02.0.00 , Thermostat Housing Cart Part No 4H.040.01.0.00 , Gear End Foot(Fuel Pump Side) Cart Part No 4H.042.05.0.00 , Gear End Foot(Alternator Side) Cart Part No 4H.042.06.0.00 , Pulley: Alternator 90 Pcd Cart Part No 4H.044.01.0.00 , Pulley Alternator ( 84.3 Pcd, S/F Ecel - 6H.2117) Cart Part No 4H.044.05.0.00 , Mounting Subassembly For Alternator Cart Part No 4H.044.20.0.00 , V Belt Cart Part No 4H.046.01.0.00 , V Belt Raw Edged Cogged Cart Part No 4H.046.02.0.00 , Flywheel Housing Cart Part No 4H.047.11.0.00 , Adaptor Sae 3 To Sae 4 For Ltk Cart Part No 4H.047.12.0.00 , Hp Pipe Complete Set 700 Mm Cart Part No 4H.050.60.0.00 , High Pressure Pipe Assembly Cart Part No 4H.050.70.0.00 , Joing: Bearing Housing Cart Part No 4H.052.11.0.00 , Joint: Delivery Volute Cart Part No 4H.052.12.0.00 , Water Pump Assly With Del Vol 282.5 Crs Cart Part No 4H.052.20.0.00 , Water Pump Assembly (Higher Bearing Size) Cart Part No 4H.052.95.0.00 , Thermostat Housing M14 Tap Both Sides Cart Part No 4H.053.01.0.00 , Thermostat Cover(Pg - 116 Height) Cart Part No 4H.053.02.0.00 , Thermostat Housing Cart Part No 4H.053.04.0.00 , Joint: Thermostat Cover Cart Part No 4H.053.08.0.00 , Thermostat Housing Assly(Pg) Cart Part No 4H.053.10.0.00 , Joint: Thermostat Housing Cart Part No 4H.053.11.0.00 , Joint: Thermostat Cover Cart Part No 4H.053.12.0.00 , Assembly Thermostat Housing Cart Part No 4H.053.50.0.00 , Thermostat Housing Assemblyboth M14top Cover Towards Fip Cart Part No 4H.053.60.0.00 , Adaptor M10x15 For Lop Guage Cart Part No 4H.057.08.0.00 , Crankcase Foot Cart Part No 4H.061.01.0.00 , Crankcase Foot Cart Part No 4H.061.02.0.00 , Flywheel End Footfor Ltk Cart Part No 4H.061.13.0.00 , Flywheel End Footfor Ltk Cart Part No 4H.061.14.0.00 , Suction Tube Cart Part No 4H.064.10.0.00 , Suction Tube Assly.(Sheet Metal Sump) Cart Part No 4H.064.20.0.00 , Starter Bracket: Pg Cart Part No 4H.065.02.0.00 , Bracket Starter Cart Part No 4H.065.03.0.00 , V Belt: Xpa 1250 Cogged Cart Part No 4H.069.01.0.00 , Belt: Spax 1300 Cogged Cart Part No 4H.069.02.0.00 , Hose: Radiator To Waterpump 45X45x130l Cart Part No 4H.073.01.0.00 , Hose: Pipe To Water Pump 45X45x80l Cart Part No 4H.073.02.0.00 , Pipe: Radiator To Water Pump Inlet Cart Part No 4H.073.03.0.00 , Upper Clamp For Pipe Cart Part No 4H.073.04.0.00 , Lower Clamp For Pipe Cart Part No 4H.073.05.0.00 , Pipe(Radiator To Pump Inlet) Cart Part No 4H.073.07.0.00 , Hose: Thermostat To Radiator Cart Part No 4H.073.08.0.00 , Metalic Breather Hose Cart Part No 4H.073.16.0.00 , Hose Water Pump Inlet To Radiator Outlet Cart Part No 4H.073.36.0.Pr , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.077.02.0.00 , Fuel Pipe ( Fuel Filter To Fuel Pump ) Cart Part No 4H.077.03.0.00 , Radiator Support Starter Side Cart Part No 4H.081.01.0.00 , Radiator Support Fuel Pump Side Cart Part No 4H.081.02.0.00 , Cross Member Forradiator Support Cart Part No 4H.081.03.0.00 , Lube Oil Sump: 3Cx Cart Part No 4H.085.01.0.00 , Set Of Joints (Turbo Pg Engine) Cart Part No 4H.087.05.0.Sp , Set Of Joints Cart Part No 4H.087.10.0.Sp , Set Of O Rings Cart Part No 4H.087.20.0.00 , Set Of Copper Washers Cart Part No 4H.087.30.0.00 , Set Of Joints Cart Part No 4H.087.40.0.Sp , Set Of O Rings For Pg: 4H.3031 Cart Part No 4H.087.50.0.00 , Set Of Copper Washer 4H.3031 Cart Part No 4H.087.60.0.00 , Set Of Joint: 4R Tc/Ta Bsiii Application Engines Cart Part No 4H.087.96.0.Sp , Set Of Joint: 4R Tc/Ta Bsiii Application Engines Cart Part No 4H.087.97.0.Sp , Accelerator Lever Pull Type (37 Mm) Cart Part No 4H.088.01.0.00 , Accelerator Lever Pull Type (27 Mm) Cart Part No 4H.088.02.0.00 , Pull Type Accelerator Lever Cart Part No 4H.088.03.0.00 , Bracket For Mounting Accelerator & Stop Cable Cart Part No 4H.088.04.0.00 , Stop Lever Cart Part No 4H.089.01.0.00 , Thermostat Cover Cart Part No 4H.096.03.0.00 , Thermostat & Housing Cart Part No 4H.096.10.0.00 , Thermostat And Mounting (M14 Adapator On Both End ) Cart Part No 4H.096.40.0.00 , Radiator Cart Part No 4H.1005.20.0.00 , Aluminium Radiator Assly Cart Part No 4H.1005.60.0.00 , Rocker Cover Cart Part No 4H.1009.90.0.00 , Dipstick Assly: 290Mm Cart Part No 4H.1027.10.0.00 , Dipstick Assembly Cart Part No 4H.1027.20.0.00 , Rocker Cover Cart Part No 4H.1028.10.0.00 , Gear Casing Cart Part No 4H.1034.01.0.00 , Gear Casing Cart Part No 4H.1034.02.0.00 , Engine Wiring Harness For 4K Crdi Cpcb 4+ Cart Part No 4H.1043.10.0.Pr , Engine Wiring Harness For 4K 125Kva Cpcb4+ Engine Cart Part No 4H.1043.20.0.Pr , Engine Wiring Harness For 4K 125Kva Cpcb Iv Cart Part No 4H.1043.80.0.Pr , Flywheel L T8 10Dp St Ring Cart Part No 4H.1044.10.0.00 , Engine Wiring Harness For 4R 82.5Kva Cpcb4+ Cart Part No 4H.1045.30.0.Pr , Engine Wiring Harness For 4R 82.5Kva Cpcb4+ Cart Part No 4H.1045.40.0.Pr , Dipstick Assembly Complete 350 Mm, S.F.35 Deg Sump Cart Part No 4H.1047.10.0.00 , Hose Cart Part No 4H.1048.02.0.00 , Turbocharger For 4Rta 1800 Rpm Engine (K24 2460 Gga 6.11) Cart Part No 4H.1050.10.0.00 , 120 Ohm1/4 Watt Mfr Type Resistance Cart Part No 4H.1062.11.0.00 , Spacer: Ext Manifold Cart Part No 4H.107.02.0.00 , Primary Filter Element Assly Cart Part No 4H.1086.01.0.00 , Safety Filter Element Cart Part No 4H.1086.02.0.00 , Air Cleaner Assly: Radial Seal Cart Part No 4H.1086.10.0.00 , Locating Bolt 80 Mm : Eye Bolt Cart Part No 4H.1089.01.0.00 , Locating Bolt 60Mm Cart Part No 4H.1089.02.0.00 , Bracket: Stay Rod Cart Part No 4H.1091.05.0.00 , Driven Hub For Compressor Cart Part No 4H.1093.01.0.00 , Housing For Compressor Drive Arrangement Cart Part No 4H.1093.02.0.00 , Driving Hub For Compressor Cart Part No 4H.1093.03.0.00 , Spider Coupling (For Compressor Drive) Cart Part No 4H.1093.04.0.00 , Joint Gear Casing Side Cart Part No 4H.1093.06.0.00 , Gear For Compressor Driving Cart Part No 4H.1093.07.0.00 , Deep Groove Ball Bearing Both Side Sealed (55 X 90) Cart Part No 4H.1093.08.0.00 , Leak Off For Fip Cart Part No 4H.1097.21.0.Pr , Leaf Off For Rail And Fip For 4K Cart Part No 4H.1097.22.0.Pr , Leak Off For Injector Cart Part No 4H.1097.23.0.00 , Fuel Pipefeed Pump To Fuel Filter Cart Part No 4H.1097.31.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 4H.1097.32.0.00 , Front Cover (Hydraulic Pump Gear Bore) Cart Part No 4H.1098.01.0.00 , Cover (Hydraulic Pump Gear Bore) Cart Part No 4H.1098.02.0.00 , Joint: Cover Plate Cart Part No 4H.1098.03.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1120.10.0.00 , Piston Assembly Complete(Gas Engine) Cart Part No 4H.1122.10.0.00 , Lube Oil Sump Cart Part No 4H.1128.01.0.00 , Spacer For Radiator Fan (35 Mm) Cart Part No 4H.1141.01.0.00 , Dipstick Assly: S/F Fab Sump Cart Part No 4H.1143.10.0.00 , Dipstick Assly Cart Part No 4H.1143.20.0.00 , Flywheel Assembly Cart Part No 4H.1171.10.0.00 , Flywheel Assembly Cart Part No 4H.1171.30.0.00 , Flywheel Assly Cart Part No 4H.1171.60.0.00 , Flywheel Assembly Cart Part No 4H.1171.85.0.Pr , Piston Ring Set 105 Dia Cart Part No 4H.1172.30.0.00 , Piston Assembly Cart Part No 4H.1172.70.0.00 , Gear Casing Cart Part No 4H.1174.01.0.00 , Gear Casing Cart Part No 4H.1174.02.0.00 , Gear Casing Cart Part No 4H.1174.04.0.00 , Gear Casing (For 4K / 6K Engine) Cart Part No 4H.1174.11.0.00 , Exhaust Mfold Cen Up Open Cart Part No 4H.1176.01.0.00 , Crankcase With Mb/Caps (Line Bore Operation) Cart Part No 4H.1179.40.0.00 , Flywheel Housing Cart Part No 4H.1180.01.0.00 , Flywheel Housing Cart Part No 4H.1183.01.0.00 , Flywheel Housingsae 3 Cart Part No 4H.1183.06.0.Pr , Alternator: 12V 65A Cart Part No 4H.1188.01.0.00 , Cover For Fuel Pump Bore Cart Part No 4H.1190.02.0.00 , Joint For Fuel Pump Gear Cover Cart Part No 4H.1190.03.0.00 , Condenser Diode & Varistor-45/62.5Kva-1 Phase Cart Part No 4H.1196.01.0.Asp , Terminal Block Assembly- 45-62.5 Kva 1 Phase Cart Part No 4H.1196.02.0.Asp , Koel Green Alternatorkg82 5 S T Framel Kg 443 Bsae 3 11 5 415V50 Hz0 8 Pf Cart Part No 4H.1196.12.0.Pr , Koel Green Alternatorcoastalhumid Environmentkg82 5 S T Framekg 44 3 B2 Cart Part No 4H.1196.17.0.Pr , Primary Element For 6M3 Air Cleaner (2990217219) Cart Part No 4H.1198.01.0.00 , Safety Element For 6M3 Air Cleaner (2990217223) Cart Part No 4H.1198.02.0.00 , Air Cleaner: Dry Typ 6 P92 Cart Part No 4H.1198.10.0.00 , Hose: Radiator To Thermostat Cart Part No 4H.1205.01.0.00 , Push Rod Cart Part No 4H.1205.02.0.00 , Hose: Makeup Water Connection Cart Part No 4H.1205.03.0.00 , Aluminium Radiator Assly: 4R1040 Cart Part No 4H.1205.90.0.00 , Radiator With 17 Fan Cart Part No 4H.1205.92.0.00 , Water Pump Assly 282.5 W/O Pulley Cart Part No 4H.1210.10.0.00 , Hose For Brather Pipe 4Rt Cart Part No 4H.1216.02.0.00 , Bracket For Speed Adjustment Cart Part No 4H.122.01.0.00 , Bar For Speed Adjustment Cart Part No 4H.122.02.0.00 , Hose: Air Cleaner Cart Part No 4H.1221.02.0.00 , Rubber Hoseturbo Toair Cleaner Cart Part No 4H.1221.04.0.00 , Engine Mtg. Foot (Fip Side) Cart Part No 4H.1223.03.0.00 , Engine Mtg. Foot ( Starter Side) Cart Part No 4H.1223.04.0.00 , Mounting Plate For Fuel Filter Cart Part No 4H.1228.01.0.00 , Emergency Stop Pbwith N0 Element Hormony Rangerelease Mushroom Type Xb5 Cart Part No 4H.1234.09.0.00 , Cover For Camshaft Bore On Gear Casing Cart Part No 4H.1235.02.0.00 , Gear Casing Joint Cart Part No 4H.1235.03.0.00 , Cover Joint Cart Part No 4H.1235.05.0.00 , Timing Pointer Cart Part No 4H.1235.06.0.00 , Gear Casing Cart Part No 4H.1235.08.0.00 , Mud Slinger Cart Part No 4H.1235.12.0.00 , Joint For Gear Casing Cart Part No 4H.1235.13.0.00 , Gear Casing Cart Part No 4H.1235.17.0.00 , Lube Oil Sump Cart Part No 4H.1247.01.0.00 , Thermostat Hosuing Assembly Cart Part No 4H.125.60.0.00 , Adaptor For Fan Cart Part No 4H.1253.02.0.00 , Fule Pipe - Fule Pump To Fuel Filter (475 Hose Length) Cart Part No 4H.1266.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1266.02.0.00 , Current Transfarmor 100/5, 5 Va Cart Part No 4H.1268.05.0.00 , Poly V Beltsect 4Pk 1255 Cart Part No 4H.1269.01.0.00 , Flywheel Assembly Cart Part No 4H.1274.10.0.00 , Front Cover Cart Part No 4H.1284.05.0.00 , Cover For Fuel Pump Gear Cart Part No 4H.1284.07.0.00 , Fuel Pump Gear Cart Part No 4H.1284.09.0.00 , Hub For Fuel Pump Gear Cart Part No 4H.1284.11.0.00 , Adaptor For Fuel Tank Breather With M12 X 1.5 Both Side Cart Part No 4H.1285.04.0.00 , Lub. Oil Sump Drain Pipe S/F New Lub. Oil Hand Pump Cart Part No 4H.1285.07.0.00 , Bush For Avm Locking Cart Part No 4H.1285.43.0.00 , Breather Hose Pipe Cart Part No 4H.1285.88.0.Pr , Flywheel Housing Cart Part No 4H.1288.01.0.00 , Exhaust Mfold: K26 Turbocharger Cart Part No 4H.129.02.0.00 , Hexagonal Socket Head Cap Screw (Copper Coated) Cart Part No 4H.129.03.0.00 , Mud Slinger S/F 4H.1295.01 Crank Pulley Cart Part No 4H.1295.02.0.00 , Pulley: Crank 4R1040 Jcb Eng Cart Part No 4H.1295.11.0.00 , Crankshaft Pulley S/F Gear Casing (6Pk 143 Pcd) Cart Part No 4H.1295.14.0.00 , Crankshaft Pulley ( 172P.C.D. Spa, 1Gr ) Cart Part No 4H.1295.21.0.00 , Pulley: Alternator 68 Pcd Cart Part No 4H.1296.01.0.00 , Water Pump Pulley: 120Pcd Cart Part No 4H.1297.01.0.00 , Alternator Pulley: 90 Pcd A Sec Cart Part No 4H.1298.01.0.00 , Exhaust Diffuser Cart Part No 4H.130.03.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.130.04.0.00 , Swivel Adaptor Cart Part No 4H.130.05.0.00 , Adaptor Ring On K26 Turbocharger Cart Part No 4H.130.06.0.00 , Joint Ss: Adaptor Ring Cart Part No 4H.130.07.0.00 , Oil Metering Orifice Cart Part No 4H.1301.04.0.00 , Crankcase Without Bearings Cart Part No 4H.1301.10.0.00 , Crankcase Assly With Mb Cap (4K1080 4V) (4H.1301.110.0.Pr) Cart Part No 4H.1301.110.0.Sp , Crankcase Assly With Mb Cap4k1080 4V Cart Part No 4H.1301.220.0.Sp , Crankcasemonoblockwith Sealing Cap Cart Part No 4H.1301.60.0.00 , Piston Cooling Nozzle Cart Part No 4H.1301.90.0.00 , Crankshaft Assly Cart Part No 4H.1302.10.0.00 , Fuel Pump 4R1040tc 105 Hp 2200 Rpm Cart Part No 4H.1308.02.0.00 , Fuel Pump 4R1040tc 110 Hp 2500 Rpmf 002 Aoz 638 Cart Part No 4H.1308.03.0.00 , Fuel Pump 4R1040tc Cart Part No 4H.1308.04.0.00 , Fuel Pump 4R1040tc 96 Hp @ 2200 Rpm Cart Part No 4H.1308.06.0.00 , Turbocharger: K24 Cart Part No 4H.1308.09.0.00 , Fuel Injection Pump For 4R1040t Engine105hp 2200Rpm Cart Part No 4H.1308.16.0.Pr , Air Delivery Pipe Cart Part No 4H.131.01.0.00 , Sleeve Cart Part No 4H.131.02.0.00 , Bracket For Air Delivery Pipe Cart Part No 4H.131.03.0.00 , Heat Shield Cart Part No 4H.131.04.0.00 , Hose: Radiator Inlet Cart Part No 4H.1318.01.0.00 , Injector S-Type (5X0.284X150x13 , 950 Htf; Nha No. E043 2252 00) Cart Part No 4H.1319.01.0.00 , Injector Cart Part No 4H.1319.03.0.00 , Adaptor: Turbocharger Side Cart Part No 4H.132.02.0.00 , Adaptor: Crankcase Side Cart Part No 4H.132.04.0.00 , Lube Oil Inlet Pipe: K24 Turbo Cart Part No 4H.132.21.0.00 , Lube Oil Drain Pipe: K24 Turbo Cart Part No 4H.132.23.0.00 , Joint: Adaptor Turbo Side Cart Part No 4H.132.27.0.00 , Joint: Adaptor Ccase Side Cart Part No 4H.132.28.0.00 , Joint: Lube Oil Drain Pipe Cart Part No 4H.132.29.0.00 , Joint: Adaptor Ccase Side Cart Part No 4H.132.31.0.00 , Adaptorfor Turbo Drain ( Crankcase Side ) Cart Part No 4H.132.32.0.00 , Nozzle Leak Off Pipe Cart Part No 4H.1321.01.0.00 , Leak Off Pipe Assembly Cart Part No 4H.1321.02.0.Pr , Leak Off Pipe Assly Cart Part No 4H.1323.20.0.00 , Leak Off Pipe Assly: 4R1050ta Cpcb Cart Part No 4H.1323.30.0.00 , V Belt: Xpa 1345 Raw Edged Cogged Cart Part No 4H.133.02.0.00 , V Belt Spax 1332 Cart Part No 4H.133.03.0.00 , Koel Green Alternatorkg 62 5 S T Framel Kg 42 3 Ksae 3 11 5 415V50 Hz0 8 Pf Cart Part No 4H.1331.07.0.00 , Koel Green Alternatorcoastal Humid Environment Kg 62 5 S T Framekg 42 3 K Cart Part No 4H.1331.08.0.Pr , 58.5Kva 1Ph ,230V, Alternator With Special Cart Part No 4H.1331.25.0.Pr , Spacer 30 Mm For Fan Mounting Cart Part No 4H.1333.01.0.00 , Rubber Hose (Heat Exchanger To Thermostat) Cart Part No 4H.1343.02.0.00 , Adaptor(For Heat Exchanger) Cart Part No 4H.1343.04.0.00 , Bracket For Heat Exchanger Mntg Cart Part No 4H.1343.05.0.00 , Heat Exchanger(S/F Fresh Water) For 4R1040 F.F. Engines Cart Part No 4H.1343.14.0.00 , Hose He To Water Pump S F 3000Rpm Cart Part No 4H.1343.24.0.Pr , Air Cleaner F.F. Engines Cart Part No 4H.1345.01.0.00 , Air Cleaner Assemblys F Fire Fighting Cart Part No 4H.1345.10.0.00 , Guard For Air Cleaner Cart Part No 4H.1345.12.0.00 , Air Cleaner F.F. Engines Cart Part No 4H.1346.01.0.00 , Air Cleaner Assembly, S/F Fire Fighting Cart Part No 4H.1346.20.0.00 , Startersolenoid(Dumore, 535-0127) 12V For F.F. Engines Cart Part No 4H.1347.01.0.00 , Clamp For Raised Type Dipstick Cart Part No 4H.1353.30.0.00 , Water Heaterkim Hotstarttps102gt12 0031Kw240v Cart Part No 4H.1355.01.0.00 , Hose For Water Heater Pipe Cart Part No 4H.1355.05.0.00 , Rubber Hose(For Water Heater) Cart Part No 4H.1355.13.0.00 , Fuel Pipe From Feed Pump To Fuel Filter Cart Part No 4H.1359.22.0.Pr , Fuel Pipe From Fuel Filter To Fip Cart Part No 4H.1359.24.0.Pr , Turbocharger Cart Part No 4H.136.10.0.00 , Turbocharger K16 2371N 5 82 For 4R1040tc Hyundai Cart Part No 4H.136.11.0.Pr , Turbocharger Cart Part No 4H.136.20.0.00 , Rectifier Diode Bridge 16Amp Hind Model No Hb37 02 Cart Part No 4H.1364.12.0.00 , Fire Pump Engine Display Controller 12Vdc Cart Part No 4H.1364.33.0.00 , Selector Switch Assembly M22 Wrk A K10 K01 Maintained Cart Part No 4H.1364.37.0.00 , Selector Switch Assembly Cart Part No 4H.1364.38.0.00 , Instrument Control Panel Assembly Digital Disply 12Vdc Cart Part No 4H.1364.60.0.00 , Fuel Supply Pipe (From Supply Block To Fuel Pump) Cart Part No 4H.1374.06.0.00 , Fuel Supply Pipe For 4R1040na Engine Cart Part No 4H.1374.08.0.00 , Leak Off Pipe Assembly Cart Part No 4H.1374.09.0.Pr , Fuel Supply And Retun Block Cart Part No 4H.1375.03.0.00 , Extension Pipe For Fuel Supply Cart Part No 4H.1375.06.0.00 , Extension Pipe For Fuel Return Cart Part No 4H.1375.07.0.00 , Gasket: Cylinder Head 1.22 Mm Thk Cart Part No 4H.1377.02.0.00 , Cylinder Head Assembly Complete Cart Part No 4H.1377.30.0.00 , Lss Turbocharger For 6K1080 Crdi Cart Part No 4H.1378.07.0.Pr , Plastic Cap For Water Pump Inlet Cart Part No 4H.138.23.0.00 , Suction Tube Cart Part No 4H.1385.40.0.00 , Lube Oil Sump Assly Cart Part No 4H.1386.10.0.00 , Lube Oil Sump Assembly Cart Part No 4H.1386.50.0.00 , Camshaft Assy4k Engine Cart Part No 4H.1387.10.0.00 , Camshaft Assy4k Engine Cart Part No 4H.1387.40.0.00 , Camshaft Assembly4k Engine 4V Common Rail Cart Part No 4H.1387.80.0.Pr , Dipstick Assembly Cart Part No 4H.1388.50.0.00 , Sub Assembly Of Rocker Cover & Breather Tube Cart Part No 4H.139.30.0.00 , Fip: 4R1040t Cart Part No 4H.1390.01.0.00 , Adaptorfor Breather Pipe Cart Part No 4H.140.01.0.00 , Breather Pipe Cart Part No 4H.140.03.0.00 , Radiator Cap Cart Part No 4H.1410.20.0.00 , Aluminium Radiator Assembly Cart Part No 4H.1410.40.0.Pr , Adaptor On Header Cart Part No 4H.1415.01.0.00 , Adaptor: Throttle Cabel Mtg Bkt Cart Part No 4H.1415.02.0.00 , Banjo Bolt Cart Part No 4H.1415.03.0.00 , Rubber Sleeve For Header (Spin On Filter Mounting Arrengement) Cart Part No 4H.1415.04.0.00 , Rubber Sleeve For Header (Spin On Filter Mounting Arrengement) Cart Part No 4H.1415.05.0.00 , Joint: Header Cart Part No 4H.1415.06.0.00 , Hose For Lub Oil 960 Mm (Both Ends Straight) Cart Part No 4H.1415.07.0.00 , Hose: Lube Oil 1030Mm One End 90? Cart Part No 4H.1415.08.0.00 , Rubbler Sleeve For Adblue Tank Clamp (25Litrs) Cart Part No 4H.1415.09.0.Pr , Hose For Lube Oil 600 Mm Cart Part No 4H.1415.12.0.00 , Bracket For Lub Oil Filter Mounting Cart Part No 4H.1415.13.0.00 , Hose For Lube Oil - Header To Filter Cart Part No 4H.1415.16.0.00 , Oil Return Pipe Cart Part No 4H.1415.17.0.Pr , Hose: Make Up Connection Cart Part No 4H.1424.03.0.00 , Hose: Make Up Water Connection Cart Part No 4H.1425.02.0.00 , Pipe (Thermostat To Radiator) Cart Part No 4H.1425.03.0.00 , Hose: Make Up Water Connection Cart Part No 4H.1425.04.0.00 , Aluminium Radiator: 4R1040t Cart Part No 4H.1425.20.0.00 , Aluminium Radiator Assembly Cart Part No 4H.1425.40.0.Pr , Injector Cart Part No 4H.1429.01.0.00 , Injector Cart Part No 4H.1429.05.0.00 , P Type Injectorassly Cart Part No 4H.1429.10.0.00 , Injector Assembly With Nozzle Cart Part No 4H.1429.14.0.00 , Injector Cart Part No 4H.1429.18.0.00 , Injectors For 3R1040ta G1 Cpcbii(56 Hp @ 1500 Rpm, Nha No. F002 C8z 981, Nozzle Tip N Cart Part No 4H.1429.23.0.00 , Injector With Vco 5X0 190X150x13deg17he 480Htfa 433 390 755With 3Mm Injector S Cart Part No 4H.1429.26.0.Pr , Packing Foot (Fwe,Starter Side) Cart Part No 4H.143.02.0.00 , Valve Seat Insert -Inlet Cart Part No 4H.1432.02.0.00 , Valve Seat Insert: Inlet Cart Part No 4H.1432.02.9.00 , Valve Seat Insert-Exhaust Cart Part No 4H.1432.03.0.00 , Valve Seat Insert: Exhaust Cart Part No 4H.1432.03.9.00 , Cylinder Head Assly Cart Part No 4H.1432.30.0.00 , Valve Pair Inlet & Exhaust Cart Part No 4H.1432.41.0.00 , Cylinder Head Assly Cart Part No 4H.1432.60.0.00 , Cylinder Head Reconditioning Kit 4R1040 Series (Indl Bsiii & Pg Engine Post 2011) Cart Part No 4H.1432.90.0.00 , Rocker Support Assembly Cart Part No 4H.1433.40.0.00 , Joint: Turbo Cart Part No 4H.1437.01.0.00 , Joint: Adaptor Cart Part No 4H.1437.02.0.00 , Adaptor (Turbocharger) Cart Part No 4H.1437.04.0.00 , Turbocharger Cart Part No 4H.1437.06.0.00 , Turbocharger Cart Part No 4H.1437.10.0.00 , Adaptor For Turbo Drain Cart Part No 4H.1437.11.0.00 , Jointfor Turbocharger Cart Part No 4H.1437.15.0.Pr , Joint Cart Part No 4H.1437.16.0.Pr , Oil Inlet Pipe Cart Part No 4H.1437.18.0.Pr , Lube Oil Drain Pipe Assembly Cart Part No 4H.1437.20.0.00 , Lube Oil Supply Pipe For Turbocharger Cart Part No 4H.1437.50.0.00 , Lube Oil Supply Pipe For Turbocharger Cart Part No 4H.1437.70.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 4H.1437.80.0.00 , Prsessure Gauge(0 - 100 Psi) Cart Part No 4H.1438.01.0.00 , Flexible Hose 1 1/4 Bsp Both Side S/F 6R1080ta Cooling Line. Cart Part No 4H.1438.24.0.00 , Avm For Cooling Line Mtg. S/F 6R & Sl90 Cart Part No 4H.1438.41.0.00 , Header For Lube Oil Cooler & Spin On Filter Cart Part No 4H.144.04.0.00 , Lube Oil Cooler -8 Plates Cart Part No 4H.144.05.0.00 , Header (For Lube Oil Cooler & Spin On Filter) (8 & 12 Plates) Cart Part No 4H.144.06.0.00 , Lub Oil Cooler8 Plates Cart Part No 4H.144.08.0.00 , Luboil Header Assembly Cart Part No 4H.144.100.0.00 , L O Cooler Header Assly Cart Part No 4H.144.60.0.00 , Drive Shaft[2040] For Fire Fighting Pump Application Cart Part No 4H.1441.19.0.00 , Injector Cart Part No 4H.1454.07.0.00 , Special Stud For Injector Cart Part No 4H.1454.13.0.00 , Nut For Injector Stud Cart Part No 4H.1454.14.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1455.150.0.Pr , Engine Wiring Harnessassembly With 4Pin &15 Pin Connector Cart Part No 4H.1464.20.0.00 , Extended Harness Assembly Cart Part No 4H.1464.30.0.00 , Engine Wiring Harnessassembly With 4Pin &15 Pin Connector Cart Part No 4H.1464.40.0.00 , Engine Wiring Harness With Csa Unit With 420Ma Gems Sensor Cart Part No 4H.1464.70.0.00 , Engine Wiring Harness For 125Kva 4K With B12 Ecu Cart Part No 4H.1465.30.0.Pr , Engine Wiring Harness With Csa Unit Sf 4K1080 Engine Cart Part No 4H.1465.40.0.Pr , Engine Wiring Harness For 125Kva 4K With Csa Unit Cart Part No 4H.1465.50.0.Pr , Engine Wiring Harness For 4K 125Kva With Csa Unit Cart Part No 4H.1465.60.0.Pr , Engine Wiring Harness For 125Kva 4K With B12 Ecu Emerald Cart Part No 4H.1465.70.0.Pr , 2 7 Kw Grs Starter Cart Part No 4H.1465.72.0.Pr , Krm For Dse 4522 A2 Without Data Plan Cart Part No 4H.1469.02.0.Pr , Actuator Xadc225d1s 12For Fire Fighting Appln Cart Part No 4H.1475.03.0.00 , Governor Card Esd 5160For Fire Fighting Appln Cart Part No 4H.1475.04.0.00 , Mtgbracket For 24V Alternator Cart Part No 4H.1481.01.0.Pr , Water Pump Pulley : 100 Pcd Cart Part No 4H.1483.11.0.00 , Water Pump And Fan Pulley Cart Part No 4H.1483.12.0.00 , Water Pump Pulley-105 Pcd, Poly V,6Pk Cart Part No 4H.1483.15.0.00 , Alternator Pulley: 56.5 Pcd Cart Part No 4H.1484.11.0.00 , Alternator Pulley Cart Part No 4H.1484.12.0.00 , Alternator Pulley (59 Pcd, Poly V, 6Pk) Cart Part No 4H.1484.15.0.00 , Alternator Pulley59 Pcdpoly V8pk Cart Part No 4H.1484.16.0.Pr , Assembly For Raised Dipstick Cart Part No 4H.1488.10.0.00 , Dipstick Assembly Cart Part No 4H.1488.40.0.00 , V Belt Spax 1265 Cart Part No 4H.1489.01.0.00 , Exhaust Diffuser For Cmvr Turbo S/F Terex Series-Ii Project Cart Part No 4H.1491.01.0.00 , Poly V Belt Cart Part No 4H.1493.01.0.00 , Poly V Belt (8 Pk 1215 Epdm) Cart Part No 4H.1493.02.0.Pr , Poly V Belt (6Pk-1190) Cart Part No 4H.1493.03.0.00 , Poly V Belt 8Pk 1148 Epdm Cart Part No 4H.1493.07.0.Pr , Raw Water Pipe Cac To He Cart Part No 4H.1494.25.0.Pr , Actuator Assembly 12V Dc For Air Cooled Engines Cart Part No 4H.150.42.0.Pr , Actuator Assembly 12V Dc For 4Rta And 6Rta Ff Engines Cart Part No 4H.150.43.0.Pr , Actuator Assembly 12V Dc For Water Cooled Engines Cart Part No 4H.150.44.0.Pr , Actuator Assembly 12V Dc For 6R Engines Pg Cart Part No 4H.150.46.0.Pr , Actuator Assembly 12V Dc For Ea10 Engines Cart Part No 4H.150.48.0.Pr , Actuator Assembly 12V Dc For Ea16 Engines Cart Part No 4H.150.49.0.Pr , Actuator Assembly 24V Dc For Sl90 Ind Application Cart Part No 4H.150.51.0.Pr , Actuator Assembly 12V Dc, With Spring (Energies To Run) Cart Part No 4H.150.53.0.Pr , Actuator Assembly 12V Dc Cart Part No 4H.150.56.0.Pr , Actuator Assembly 12V Dc Cart Part No 4H.150.57.0.Pr , Actuator Assembly 12V Dc For 4Rna Ff Engines Cart Part No 4H.150.58.0.Pr , Actuator Assembly 12V Dc For R810 Ff Engines Cart Part No 4H.150.61.0.Pr , Actuator Assembly 24V Dc For Sl90 Ff Engines Cart Part No 4H.150.62.0.Pr , Actuator Assembly 24V Dc For 6R Engines Ff Cart Part No 4H.150.63.0.Pr , Piston Assly R1040na Cmvr Stg-Ii Cart Part No 4H.1502.10.0.00 , Turbocharger Hsg: Tr59_6.1 Cart Part No 4H.1519.01.0.00 , Turbocharger Cart Part No 4H.1519.02.0.00 , Turbocharger Cart Part No 4H.1519.04.0.00 , Tr59_6.1 Hsg Turbocharger Cart Part No 4H.1519.05.0.00 , Turbo In Lub Oil Pipe Cart Part No 4H.1519.10.0.00 , Turbo Out Lub Oil Pipe Cart Part No 4H.1519.20.0.00 , Flywheel Assembly Cart Part No 4H.1524.10.0.00 , Injector For 4R/6R Fmul Engines (F002 C8z 994) Cart Part No 4H.1529.02.0.00 , Piston Assembly Cart Part No 4H.153.10.0.00 , Rotary Fip: 4K1080ta 125 Kva Cart Part No 4H.1534.01.0.00 , Fip 12V System With Csa Cart Part No 4H.1534.11.0.00 , 4K Cpcb Ii Fip 24V System With Csa Cart Part No 4H.1534.12.0.00 , Injector Cart Part No 4H.154.10.0.00 , Exhaust Manifold For K-26 Turbocharger Cart Part No 4H.1543.01.0.00 , Air Pipeturbocharger To Inlet Manifold Cart Part No 4H.1543.02.0.00 , Air Pipe Turbo To Inlet Manifold Cart Part No 4H.1543.03.0.Pr , Exhaust Manifold Cart Part No 4H.1543.04.0.Pr , Bracket For Remote Hand Primer Pump Mounting Cart Part No 4H.1546.01.0.00 , Adaptor For Air Cleaner For Ace Cart Part No 4H.1547.01.0.00 , Flywheel Assembly Cart Part No 4H.1548.10.0.00 , Motorpal Fuel Injection Pump For 4R1040ta 2600 & 2350 Rpm Cart Part No 4H.1549.04.0.00 , Sub Assly Spl Banjo Bolt (For Oil Spray Nozzle) Cart Part No 4H.156.07.0.00 , Crankcase Assly Without Bearingsw O Guide Cart Part No 4H.156.100.0.00 , Piston Cooling Nozzle Cart Part No 4H.156.11.0.00 , Ccase Assly W/O Bearing Cart Part No 4H.156.20.0.00 , Mounting Bracket For Alternator Cart Part No 4H.1563.01.0.00 , Mounting Bracket For Alternator Cart Part No 4H.1563.02.0.Pr , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.158.04.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 4H.158.05.0.00 , Flywheel Housing Sae 3, 144.5 Width Cart Part No 4H.1584.01.0.00 , Bracket For Fuel Solenoid(Cold Starting Kit) Cart Part No 4H.1590.01.0.00 , Fuel Pipe Assembly Solenid To Heater Cart Part No 4H.1590.10.0.00 , Hose: Air Cleaner Cart Part No 4H.1591.01.0.00 , Sub Assembly Of Rocker Cover & Breather Pipe Cart Part No 4H.160.10.0.00 , Fuel Injection Pump 4R1040na 60Hp@1900Rpm Cart Part No 4H.1605.10.0.00 , Breather Pipe Cart Part No 4H.161.05.0.00 , Clip For Breather Pipe Cart Part No 4H.161.06.0.00 , Joint: Breather Pipe Cart Part No 4H.161.11.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.15.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.21.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.27.0.Pr , Set Of Joints Cart Part No 4H.1612.56.0.Sp , Valve Seat Insert: Exhaust Cart Part No 4H.1613.04.9.00 , Valve Seat Insert: Inlet Cart Part No 4H.1613.05.9.00 , Injector Sleeve Cart Part No 4H.1613.06.0.00 , O Ring For Injector Sleeve Cart Part No 4H.1613.07.0.00 , Valve Stem Seal Cart Part No 4H.1613.11.0.00 , Valve Cup Cart Part No 4H.1613.14.0.00 , Spring Cup Cart Part No 4H.1613.15.0.00 , Valve Collet Cart Part No 4H.1613.16.0.00 , Valve Spring Cart Part No 4H.1613.17.0.00 , Valve Bridge Cart Part No 4H.1613.18.0.00 , Dowel For Rocker Support (4K1080 4 Valve) Cart Part No 4H.1613.27.0.00 , Cyl Head Assemblycomplete Cart Part No 4H.1613.30.0.00 , Valve Bridge (Finish) Cart Part No 4H.1613.36.0.00 , Cylinder Head Gasket -Mls Cart Part No 4H.1613.37.0.00 , Valve Guide & Snap Ring Assembly Cart Part No 4H.1613.50.0.00 , Bolt For Cylinder Head Cart Part No 4H.1613.52.0.Pr , Crank Pulley Cart Part No 4H.1613.53.0.Pr , Cylinder Head Gasket Cart Part No 4H.1613.54.0.Pr , Inlet & Exhaust Valve Pair Cart Part No 4H.1613.90.0.00 , Push Rod Cart Part No 4H.1614.16.0.00 , Spacer: Head & Rocker Box Cover Cart Part No 4H.1614.21.0.00 , Spacer (Id 9 X Od 14 X 9.5 L) Cart Part No 4H.1614.38.0.Pr , Valve Rocker Assembly Cart Part No 4H.1614.80.0.00 , Flywheel Housing Cart Part No 4H.1616.01.0.00 , Adaptor On Flywheel Cart Part No 4H.1617.02.0.00 , Flywheel Cart Part No 4H.1617.10.0.00 , Lube Oil Sump Cart Part No 4H.1618.01.0.00 , Baffle Plate Cart Part No 4H.1618.03.0.00 , Assembly Suction Tube Cart Part No 4H.1619.20.0.00 , Fan Spacer 60 Mm Cart Part No 4H.1621.02.0.00 , Spacer For Fan (50 Mm) Cart Part No 4H.1621.03.0.00 , L Odrain Pipe Cart Part No 4H.1622.02.0.Pr , Adaptor Assly For Turbo Drain Cart Part No 4H.1622.03.0.00 , Lo Drain Pipe Assembly Cart Part No 4H.1622.04.0.00 , Head Machined For Bolt 50.003.08.020 - Hyundai Project Cart Part No 4H.1622.05.0.00 , Rocker Box Cart Part No 4H.1624.02.0.00 , Grommet (For Rocker Cover) Cart Part No 4H.1625.03.0.00 , Rocker Cover Cart Part No 4H.1625.11.0.00 , Baffle Plate Cart Part No 4H.1625.23.0.00 , O Ring For Rocker Cover Cart Part No 4H.1625.26.0.00 , Dome Nut Cart Part No 4H.1625.27.0.00 , Spherical Washer Cart Part No 4H.1626.03.0.00 , Nozzle Clamp Cart Part No 4H.1626.05.0.00 , Nozzle Clamp (Finish) Cart Part No 4H.1626.08.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.1629.03.0.00 , Inlet Manifold Cart Part No 4H.1629.04.0.00 , Gasket For Exhaust Manifold Cart Part No 4H.1630.02.0.00 , Exhaust Manifold Cart Part No 4H.1630.07.0.00 , Gasket (Bet. Cylinder Head & Exhaust Manifold) Cart Part No 4H.1630.09.0.Pr , Crankshaft Pulley Cart Part No 4H.1636.01.0.00 , Pulley For Alternator Cart Part No 4H.1637.01.0.00 , O Ring Cart Part No 4H.1641.02.0.00 , Thermostat & Housing Cart Part No 4H.1641.10.0.00 , Fuel Tank Unit Cart Part No 4H.1649.06.0.00 , Joint For Cover Plate Cart Part No 4H.1649.14.0.00 , Fuel Tank: 130 High Cart Part No 4H.1649.21.0.00 , Fuel Tank S/F: 180 High Cart Part No 4H.1649.24.0.00 , Fuel Tank Unit S F 205 Effective Tank Height Cart Part No 4H.1649.31.0.Pr , Fuel Tank Unit S F 180 Effective Tank Height Cart Part No 4H.1649.34.0.00 , Fuel Tank Unit With 272 Effective Height Cart Part No 4H.1649.37.0.00 , Fuel Tank Unit 280Mm Cart Part No 4H.1649.41.0.00 , Fuel Tank Unit S F 276 Effective Tank Height Cart Part No 4H.1649.42.0.Pr , Fuel Injection Pump Turbo -V.S. Cart Part No 4H.165.10.0.00 , Piston Assembly: Gallery Cooled Piston Cart Part No 4H.1650.10.0.00 , Piston Ring Set Cart Part No 4H.1650.20.0.00 , Piston Assembly Cart Part No 4H.1650.60.0.00 , Piston Assembly Complete Cart Part No 4H.1650.75.0.Pr , High Pressure Pipe Assembly Cart Part No 4H.1653.50.0.00 , Leak Off Pipe Cart Part No 4H.1658.01.0.00 , Leak Off Pipe For Fip & Injector Cart Part No 4H.1658.04.0.00 , Leak Off Pipe (For Filter) Cart Part No 4H.1658.07.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1659.50.0.00 , Rubber Hose: Air Cleaner Cart Part No 4H.166.06.0.00 , Bracket For Air Cleaner Cart Part No 4H.166.08.0.00 , Air Cleaner Assly: Dry Type Cart Part No 4H.166.10.0.00 , Primary Filter Element Cart Part No 4H.166.11.0.00 , Clamp For Dipstick Assy. For 35 Deg Inclination Oil Sump Cart Part No 4H.1660.01.0.00 , Dipstick Assly Cart Part No 4H.1660.10.0.00 , Crank Pulley With Poly V Groove Cart Part No 4H.1661.01.0.00 , Water Pump Pulley Poly V Groove-138 Pcd Cart Part No 4H.1662.01.0.00 , Water Pump Pulley : Poly V Groove Cart Part No 4H.1662.11.0.00 , Alternator Pulley With Poly V Groove 90 Pcd Cart Part No 4H.1663.01.0.00 , Poly V Belt Cart Part No 4H.1664.01.0.00 , V Belt Sect 6Pk -1215 Poly Cart Part No 4H.1664.02.0.00 , 62 5 Kvaalternator Terminal Box Cart Part No 4H.1666.05.0.00 , 62.5 Kva Alternator Fan Cart Part No 4H.1666.06.0.00 , Alternatorwound Exciter Stator Cart Part No 4H.1666.07.0.00 , 62.5 Kva Alternator Wound Exciter Rotor Cart Part No 4H.1666.08.0.00 , 62.5 Kva Alternator Diode Bridge Rectifier Cart Part No 4H.1666.11.0.00 , Alternatorde Adaptor M Clsap 423Sae 3 60 Kva Cart Part No 4H.1666.12.0.00 , 62.5 Kva Alternator Nde Flange Cart Part No 4H.1666.14.0.00 , 62.5 Kva Alternator Coupling Disc Assly Cart Part No 4H.1666.15.0.00 , Space Heater Kit Cart Part No 4H.1666.16.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.167.01.0.00 , Adaptor Ring On K24 Turbocharger Cart Part No 4H.167.02.0.00 , Joint: Adaptor Ring Cart Part No 4H.167.03.0.00 , Dipstick Bracket S F Jcb Cart Part No 4H.1678.02.0.00 , Air Delivery Pipe Cart Part No 4H.168.01.0.00 , Rubber Hose: Compressor Outlet- K24 Turbo Cart Part No 4H.168.03.0.00 , Rubber Hose Cart Part No 4H.168.11.0.00 , Relay (12 Vdc)Mounting Box Cart Part No 4H.1684.09.0.00 , Cold Starting Kit Cart Part No 4H.1684.18.0.00 , Cold Start Power Relay Mounting Box Cart Part No 4H.1684.32.0.Pr , Engine Heater Wiring Kit Cart Part No 4H.1684.60.0.00 , Cold Startting Kit Cart Part No 4H.1684.71.0.Sp , Multifunction Timer Relay 12 240 V Ac Dc 2 C Ore22r2mmw 1Cmdtf Cart Part No 4H.1685.23.0.Pr , Assembly For 4K Engine Heater Kit Cart Part No 4H.1686.50.0.00 , 4K Air Heater Wiring Harness Cart Part No 4H.1686.60.0.Pr , Control Panel Assembly For 125Kva 4K Cpcb4 Cart Part No 4H.1686.90.0.Pr , Cold Start Kit Main Assembly For L3 Level Application 12V System4k 125Kva Cart Part No 4H.1689.30.0.Pr , Cold Start Kit Assembly For L3 Level Application 12V System82 5Kva Cart Part No 4H.1689.70.0.Pr , Inlet Cap (76 Dia Pipe) Cart Part No 4H.169.01.0.00 , Air Cleaner Assembly Cart Part No 4H.169.10.0.00 , Cold Start Kit Main Assembly For L2 Level Application(12V System) 4K 125Kva Cart Part No 4H.1690.30.0.Sp , Control Panel Schematic For 82 5Kva3ph With Kg645 Ip A Cart Part No 4H.1696.80.0.Pr , Control Panel Schematic For 82 5Kva3ph With Kg640 Ip A Cart Part No 4H.1696.90.0.Pr , Lifting Hook Cart Part No 4H.170.01.0.00 , Lifting Hook Cart Part No 4H.170.04.0.00 , Rotary Fip: 4R1040tc76 Hp @ 2200 Rpm Cart Part No 4H.1705.02.0.00 , Jointfor Rotary Fip Cart Part No 4H.1705.04.0.00 , Rotary Fip: 4R1040tc76 Hp @ 2200 Rpm Cart Part No 4H.1705.08.0.00 , Charging Alternator Cart Part No 4H.1706.01.0.00 , Charging Alternatorsealed Type12 14V 90A Cart Part No 4H.1706.11.0.Pr , Pulley 65 Pcd Spa V Section For Sealed Alternator Cart Part No 4H.1706.12.0.Pr , Pulley 68 Pcd Poly V 6Pk For Sealed Alternator Cart Part No 4H.1706.13.0.Pr , Rotary Fip 4R1040ta296 Hp @ 2200 Rpm Cart Part No 4H.1707.10.0.00 , Rotary Fip :4R1040ta3105 Hp @ 2200 Rpm Cart Part No 4H.1708.20.0.00 , Fan: 494 Dia 30 Deg Cart Part No 4H.1710.10.0.00 , Fan: 494 Dia 30 Deg Cart Part No 4H.1710.20.0.00 , Fuel Return Line Nrv Adaptor (Type Ii) Cart Part No 4H.1711.12.0.00 , Air Pipe(Turbocharger To Cac) Cart Part No 4H.1712.02.0.00 , Air Pipe(Cac To Air Inlet) Cart Part No 4H.1712.03.0.00 , Hose: Make Up Connection Cart Part No 4H.1712.07.0.00 , Stay Rod: Radiator Cart Part No 4H.1712.09.0.00 , Vent Pipe:Radiator Cart Part No 4H.1712.11.0.00 , Air Delivery Bend Cart Part No 4H.1712.15.0.00 , Hose: Air Pipe -Tc To Cac Cart Part No 4H.1712.18.0.00 , Bracket For Air Pipe Cart Part No 4H.1712.22.0.00 , Bracket For Gas Outlet Manifold Cart Part No 4H.1712.23.0.00 , Hose T-Bolt Clamp Cart Part No 4H.1712.24.0.00 , Air Pipe (Radiator To Bend Pipe) Cart Part No 4H.1712.28.0.00 , Bracket For Cac Pipe Cart Part No 4H.1712.29.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 4H.1712.31.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No 4H.1712.32.0.00 , Cac Hose (Cold Side) Cart Part No 4H.1712.33.0.00 , Bracket For Cac Pipe Support Cart Part No 4H.1712.36.0.00 , Cac Hose (Cold Side) Cart Part No 4H.1712.39.0.00 , Air Pipe (Radiator To Bend Pipe) Cart Part No 4H.1712.49.0.Pr , Drain Pipe800 Mm Long Cart Part No 4H.1713.02.0.00 , Lube Oil Drainpipe From Pump To Base Plate Cart Part No 4H.1713.03.0.00 , Drain Pipe From Sump To Hand Pump Cart Part No 4H.1713.04.0.00 , Pipe-Thermostat To Radiator Cart Part No 4H.1714.05.0.00 , Hose: Radiator To Water Pump Cart Part No 4H.1714.06.0.00 , Pipe (Thermostat To Radiator Inlet) Cart Part No 4H.1714.07.0.00 , Expansion Bellow Cart Part No 4H.1715.01.0.00 , Expansion Bellow Cart Part No 4H.1715.04.0.00 , Expansion Bellow Cart Part No 4H.1715.05.0.00 , Anti Vibration Mounts Cart Part No 4H.1716.01.0.00 , Anti Vibration Mounts Cart Part No 4H.1716.02.0.00 , Spacer For Fan (40Mm) Cart Part No 4H.1717.02.0.00 , Fan Assly: 26 Pusher Cart Part No 4H.1717.03.0.00 , Spacer For Fan Cart Part No 4H.1717.07.0.00 , Pipe Radiator To Water Pump Cart Part No 4H.1718.02.0.00 , Breather Hose Rocker Cover To Bend Pipe Cart Part No 4H.1718.07.0.00 , Breather Hose Cart Part No 4H.1718.08.0.00 , Rotary Fip: 4R1040ta190 Hp @ 2200 Rpm Cart Part No 4H.1719.01.0.00 , Actuator With Spring Cart Part No 4H.1720.01.0.00 , Ecu: 4K1080ta-125 Kva Cart Part No 4H.1720.02.0.00 , Actuator With Reverse Spring Cart Part No 4H.1720.05.0.00 , Ecu With Csa Output Cart Part No 4H.1720.12.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1724.10.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1724.20.0.00 , Rotary Fip: 4R1040ta4110 Hp @ 2500 Rpm Cart Part No 4H.1729.01.0.00 , Control Panel Schematic For 4K 125Kva With Csa Unit Cart Part No 4H.1738.75.0.Pr , Adaptor For Air Cleaner Cart Part No 4H.174.02.0.00 , Poly V Belt : 6Pk 1230 Cart Part No 4H.1744.01.0.00 , Crankshaft Pulley 6Pk 145 Pcd Cart Part No 4H.1745.01.0.00 , Crank Pulley: Poly V Groove Cart Part No 4H.1746.01.0.00 , Water Pump Pulley: V Groove Cart Part No 4H.1747.01.0.00 , Alternator Pulley: Poly V Groove Cart Part No 4H.1748.01.0.00 , Crank Pulley: Poly V Groove Cart Part No 4H.1749.01.0.00 , Alternator Pulley: Poly V Groove Cart Part No 4H.1750.01.0.00 , Crank Shaft Pulley With Poly V Groove (P6pk172) Cart Part No 4H.1755.01.0.00 , Gear Casing Cart Part No 4H.178.02.0.00 , Mud Slinger (Bottom Side) Cart Part No 4H.178.07.0.00 , Bracket For Silencer Cart Part No 4H.1787.04.0.00 , Hose: Air Cleaner Cart Part No 4H.1787.05.0.00 , Hose: Air Cleaner Cart Part No 4H.1788.05.0.00 , Front Cover Cart Part No 4H.179.02.0.00 , Mud Slinger (Top Side) Cart Part No 4H.179.04.0.00 , Engine Wiring Harness: Kg934 Cart Part No 4H.1790.10.0.00 , Engine Wiring Harness Assembly Cart Part No 4H.1790.60.0.00 , Panel To Engine Wiring Harness Cart Part No 4H.1790.70.0.00 , Wiring Harness Assly: Surge Suppress Cart Part No 4H.1791.60.0.00 , Exhaust Manifold Cart Part No 4H.1792.01.0.00 , Engine Wiring Harnessassembly Sf Dse 4522 A2 Unit With Governerfor 4K Engine Cart Part No 4H.1792.30.0.Pr , Cross Member Forradiator Support Cart Part No 4H.1793.01.0.00 , Lube Oil Supply Pipe Assly Cart Part No 4H.1795.10.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 4H.1795.20.0.00 , Hose: Pre Clean To Air Clean Bsiii Cart Part No 4H.1796.05.0.00 , Air Cleaner Assly 8 M3/Min Cart Part No 4H.1796.10.0.00 , Silencer Cart Part No 4H.1797.01.0.00 , Tail Pipe For Exhaust Silencer Of76 Hp 2200 Rpm Bs Iii Engine Cart Part No 4H.1797.02.0.00 , Clamp Assembly Cart Part No 4H.1797.20.0.00 , Bracket For Accelerator & Stop Cable Mounting Cart Part No 4H.1799.02.0.00 , Piston Assembly Cart Part No 4H.180.10.0.00 , Piston Assembly Completefor Fmul Application Cart Part No 4H.180.100.0.00 , Piston Assembly Cart Part No 4H.180.120.0.00 , Piston Assembly Complete Cart Part No 4H.180.15.0.00 , Hose: Water Pump To Radiator Cart Part No 4H.1800.01.0.00 , Dry Type Air Cleaner Assembly (8-M3min) Cart Part No 4H.1808.10.0.Pr , Crankshaft Assly With Gear Cart Part No 4H.181.10.0.00 , Crankshaft Assembly Cart Part No 4H.181.30.0.00 , Air Cleaner Safety Element Cart Part No 4H.1810.01.0.00 , Air Cleaner Primary Element Cart Part No 4H.1810.02.0.00 , Hose Redicer Bet Air Cleaner And Pre Cleaner Cart Part No 4H.1810.03.0.00 , Rubber Sleeve Small -For Pre-Cleaner Cart Part No 4H.1810.04.0.00 , Rubber Sleeve Large - For Air Cleaner Cart Part No 4H.1810.05.0.00 , Air Cleaner Cart Part No 4H.1810.50.0.00 , Air Cleaner Assly Cart Part No 4H.1810.60.0.00 , Exhaust Diffuser Cart Part No 4H.1812.01.0.00 , Poly V Belt 6Pk:1325 4R1040ta Cart Part No 4H.1814.02.0.00 , Fan: 494 Dia 35 Deg Cart Part No 4H.1818.10.0.00 , Fan: 494 Dia 35 Deg Cart Part No 4H.1819.10.0.00 , Exhaust Silencer Cart Part No 4H.1820.01.0.00 , Diffuser Cart Part No 4H.1821.01.0.00 , Bracket: Exh Diff Support Cart Part No 4H.1822.04.0.00 , Exhaust Diffuser Cart Part No 4H.1822.05.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.1822.07.0.Pr , Hose: Air Cleaner Cart Part No 4H.1823.01.0.00 , B12 E Governor Harness Diagram Serial Programming Cart Part No 4H.1825.11.0.Pr , B12 E Governor Serial Programming Harness Cart Part No 4H.1825.12.0.Pr , Engine To Panel Wiring Harnessassembly With 4Pin15 Pin Connector Cart Part No 4H.1825.30.0.00 , Crankshaft Pulley Cart Part No 4H.1827.02.0.00 , Crankshaft Pulley Cart Part No 4H.1827.03.0.00 , Bracket For Air Cleaner Mounting Cart Part No 4H.1828.01.0.00 , Hose: Air Cleaner Cart Part No 4H.1828.02.0.00 , Hose: Air Cleaner Cart Part No 4H.1828.03.0.00 , Safety Filter Element Cart Part No 4H.183.01.0.00 , Air Cleaner Assly: 8M3 Indl Cart Part No 4H.183.10.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.1832.01.0.00 , Fuel Pipe: Mud Filter To Feed Pump Cart Part No 4H.1832.02.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1832.03.0.00 , 230V Ac 16Mm Red Colour Lamp Cart Part No 4H.1840.15.0.00 , Crank Pulley Cart Part No 4H.1867.01.0.00 , Hose For Air Cleanerbs Iii Cart Part No 4H.1873.01.0.00 , Hose For Precleaner Cart Part No 4H.1873.02.0.00 , Raised Dipstick Assly Cart Part No 4H.1874.10.0.00 , F 002 A0z 964 Inline Fip4r1040ta102 Hp1500 Rpm Cpcb Ii Cart Part No 4H.1890.02.0.00 , Engine Wiring Harness Assembly With Kg 934 Cart Part No 4H.1904.40.0.00 , Engine Wiring Harness For 82 5Kva 4R1040 Emerald Cart Part No 4H.1904.90.0.Pr , Engine Wiring Harness For 4Rta Engine Cart Part No 4H.1905.70.0.Pr , Shim For Speed & Phase Sensors Cart Part No 4H.1911.03.0.00 , Shim For Speed Phase Sensorsthick 0 8 Cart Part No 4H.1911.06.0.00 , Shim For Speed Phase Sensorsthick 1 1 Cart Part No 4H.1911.07.0.00 , Shim For Speed Phase Sensorsthick 1 5 Cart Part No 4H.1911.08.0.00 , Hub For Fuel Pump Gear S F Common Rail Engine Cart Part No 4H.1915.01.0.00 , Pipe Assembly (From Pump To Solenoid) Cart Part No 4H.1926.01.0.00 , Pipe Assemblysolenoid To Heater Cart Part No 4H.1926.02.0.00 , Bracket For Solenoid Mounting Cart Part No 4H.1926.03.0.00 , Routed High Pressure Pipe 1Pump To Rail Cart Part No 4H.1927.101.0.Pr , Routed High Pressure Pipe 2Pump To Rail Cart Part No 4H.1927.102.0.Pr , Routed High Pressure Pipe Cylinder 1Rail To Injector Cart Part No 4H.1927.111.0.Pr , Routed High Pressure Pipe Cylinder 2Rail To Injector Cart Part No 4H.1927.112.0.Pr , Routed High Pressure Pipe Cylinder 3Rail To Injector Cart Part No 4H.1927.113.0.Pr , Routed High Pressure Pipe Cylinder 4Rail To Injector Cart Part No 4H.1927.114.0.Pr , Gear Casings F Hydraulic Pump Cart Part No 4H.1930.01.0.Pr , Bracket For Alternator Mounting Cart Part No 4H.1930.03.0.Pr , Cover For Cam Bore Cart Part No 4H.1930.06.0.Pr , Cover For Hyd. Pump Bore Cart Part No 4H.1930.07.0.00 , Joint (For Gear Casing) Cart Part No 4H.1930.08.0.00 , Joint (For Compressor Cover) Cart Part No 4H.1930.09.0.00 , Joint (For Gear Cover) Cart Part No 4H.1930.11.0.00 , Joint (For Fip Cover) Cart Part No 4H.1930.12.0.00 , Cam Tone Wheels F Common Rail Cart Part No 4H.1932.05.0.Pr , Cam Tone Wheel3 Tooth Cart Part No 4H.1932.08.0.Pr , Bend Pipe For Throttle Cart Part No 4H.1934.05.0.Pr , Gasketfor Adaptor Cart Part No 4H.1934.06.0.00 , Valve Bridge (Finish) (4K 4V, Common Rail) Cart Part No 4H.1938.03.0.Pr , Adaptorfor Centrifuge Luboil Filter Cart Part No 4H.1939.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1942.02.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No 4H.1942.03.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 4H.1942.12.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 4H.1942.13.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1943.60.0.00 , Lube Oil Pump Cart Part No 4H.1944.30.0.00 , Cylinder Head Assly Complete Cart Part No 4H.1946.70.0.Pr , H.P.Pipe Complete Set (700 Mm) Cart Part No 4H.1950.60.0.00 , Exhaust Diffuser Cart Part No 4H.1951.01.0.00 , Jointbetween Turbo Diffuser Cart Part No 4H.1951.02.0.00 , Bracket For Diffuser Cart Part No 4H.1951.03.0.00 , Heat Shield (Integral With Diffuser Joint) Cart Part No 4H.1951.04.0.00 , Bracket For Diffuser Support Cart Part No 4H.1951.17.0.Pr , Oil Supply Pipe For Fip Cart Part No 4H.1960.10.0.Pr , Exhaust Diffuser Cart Part No 4H.1966.01.0.Pr , Locating Bolt : 65Mm Eye Bolt Cart Part No 4H.198.02.0.00 , Spacer (For Eye Bolt) Cart Part No 4H.198.03.0.00 , Belt Guard Cart Part No 4H.198.04.0.00 , Belt Gaurd For Alternator Cart Part No 4H.198.07.0.00 , Belt Guard For Charching Alt Cart Part No 4H.198.19.0.00 , Belt Guard For Alt Cart Part No 4H.198.21.0.00 , Charging Alternator Belt Guard Cart Part No 4H.198.61.0.Pr , Closed Crankcse Ventilation (Ccv) Cart Part No 4H.1989.01.0.Pr , Adaptor Cart Part No 4H.1989.09.0.Pr , Headerfor Lub Oil Cooler Spin On Filter Cart Part No 4H.1990.01.0.Pr , Gasket For Lub Oil Header Cart Part No 4H.1990.02.0.Pr , Header Cart Part No 4H.1990.03.0.Pr , Socket Head Grub Screw - M24x1.5X40 Cart Part No 4H.1990.04.0.Pr , Socket Head Grub Screw - M20x1.5X30 Cart Part No 4H.1990.05.0.Pr , Alternator Fan Od 421 Mm Frame Kg 44 3 Cart Part No 4H.1996.55.0.Pr , Belt V Type A Section Epdm V13x1318 Cart Part No 4H.1998.01.0.00 , Ecu Cart Part No 4H.1999.02.0.00 , Ecu Cart Part No 4H.1999.03.0.Pr , Joint: Sheet Metal Sump Cart Part No 4H.201.01.0.00 , Hose: Air Cleaner Cart Part No 4H.215.01.0.00 , Exhaust Manifold Cart Part No 4H.220.01.0.00 , Fuel Filter Cartridge Cart Part No 4H.2206.01.0.00 , Fuel Filter Assly Cart Part No 4H.2206.10.0.00 , Fuel Filter Assly-Rotry Fip Cart Part No 4H.2206.30.0.00 , Main Fuel Filter Cartridge With 3 Stage Water Separation Cart Part No 4H.2206.60.0.Pr , Expansion Bellow: K24 Turbo Cart Part No 4H.221.06.0.00 , Hexagonal Socket Head Cap Screw M8x18l Cart Part No 4H.221.07.0.00 , Exhaust Diffuser Cart Part No 4H.221.08.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.221.09.0.00 , Lube Oil Inlet Pipe Cart Part No 4H.222.01.0.00 , Lube Oil Drain Pipe Cart Part No 4H.222.03.0.00 , Air Inlet Manifold Cart Part No 4H.223.01.0.00 , Air Inlet Manifold(S/F Flame Heater Mounting) Cart Part No 4H.223.03.0.00 , Inlet Manifold Cart Part No 4H.223.04.0.00 , Inlet Manifold Cart Part No 4H.223.05.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.223.11.0.00 , Bracket For Air Pipe Cart Part No 4H.224.02.0.00 , U Clamp Cart Part No 4H.224.03.0.00 , Air Pipe: Cac To Air Inlet Mfold Cart Part No 4H.224.04.0.00 , Air Pipe Turbo Side Cart Part No 4H.224.06.0.00 , Air Pipe Cac Side Cart Part No 4H.224.07.0.00 , Joint: Air Pipe Cart Part No 4H.224.08.0.00 , Cap Forcacpipe Cart Part No 4H.224.13.0.00 , Air Delivery Bend Cart Part No 4H.224.14.0.00 , Spacer (Between Turbo & Air Pipe) Cart Part No 4H.224.15.0.00 , O Ring: Spacer - Turbo & Air Pipe) Cart Part No 4H.224.16.0.00 , Air Pipecac To Air Inlet4k1080 4V Cart Part No 4H.224.17.0.00 , Air Pipe Cac To Inlet Manifold Cart Part No 4H.224.21.0.00 , Joint: Air Inlet Manifold & Air Pipe Cart Part No 4H.224.35.0.00 , Air Pipe (Bend) Cart Part No 4H.224.43.0.00 , Air Pipe Cart Part No 4H.224.44.0.00 , Flange Heater Cart Part No 4H.224.45.0.00 , Flange Heater 24V Cart Part No 4H.224.48.0.00 , V Bend Clampdia 72 4 Cart Part No 4H.224.53.0.Pr , Spacer (Cac Pipe & Bend Pipe) Cart Part No 4H.224.54.0.Pr , O Ring Cart Part No 4H.224.57.0.Pr , Cac Hosecold Side Cart Part No 4H.224.68.0.Pr , Air Delivery Pipe Cart Part No 4H.224.72.0.Pr , Flange Heater 0 5 Kw Cart Part No 4H.224.98.0.Pr , Flange Heater 1 5Kw Cart Part No 4H.224.99.0.Pr , Bracket For Radiator Stay Cart Part No 4H.225.01.0.00 , Stay For Radiator Cart Part No 4H.225.02.0.00 , Spacer For Bracket Cart Part No 4H.225.06.0.00 , Vent Pipe Cart Part No 4H.225.09.0.00 , Adaptor Forvent Pipe Cart Part No 4H.225.11.0.00 , Hose: Makeup Water Line Cart Part No 4H.225.12.0.00 , Spacer For Vent Connection Cart Part No 4H.225.13.0.00 , Adaptor: Water Temp Switch Cart Part No 4H.225.14.0.00 , Adaptor For Water Temp. Sensor Cart Part No 4H.225.22.0.00 , Stay For Radiator Cart Part No 4H.225.25.0.00 , Adaptor For Water Temp Switch Cart Part No 4H.225.29.0.00 , Adaptor For Raw Water Tempswitch Cart Part No 4H.225.43.0.Pr , Flange Heater 12V Dc 1000 Watts Cart Part No 4H.225.61.0.Pr , Pipe (Thermostat To Radiator Inlet) Cart Part No 4H.226.02.0.00 , Rubber Pipe: Radiator Out To Water Pump Cart Part No 4H.226.06.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 4H.226.08.0.00 , Hose: Make Up 4R Ta Cart Part No 4H.226.14.0.00 , Hose :Thermostat To Radiator Inlet Cart Part No 4H.226.15.0.00 , Hose: Rad Out To Engine In Cart Part No 4H.226.16.0.00 , Air Cleaner Mtg Bracket Cart Part No 4H.227.01.0.00 , Hose: Air Cleaner Cart Part No 4H.227.02.0.00 , Air Cleaner Bracket For 6H.412.20 Air Cleaner Cart Part No 4H.227.11.0.00 , Hose: Air Cleaner Cart Part No 4H.227.12.0.00 , Rubber Hose (For Air Cleaner) Cart Part No 4H.227.22.0.00 , Crankcase Foot(F P Side 225 Ht) Cart Part No 4H.228.01.0.00 , Crankcase Foot (Starter Side 225 Ht) Cart Part No 4H.228.02.0.00 , Bracket For Mud Filter Cart Part No 4H.228.11.0.00 , Spacer For 24V Starter (29.8 Mm Width) Cart Part No 4H.230.01.0.00 , Suction Tube Cart Part No 4H.231.10.0.00 , Adaptor: Lube Oil Press Sensor Cart Part No 4H.235.01.0.00 , Adaptor For Lopswitch Cart Part No 4H.235.11.0.00 , Adaptor For Lop Sensor Cum Switch Cart Part No 4H.235.12.0.00 , Adaptor Cart Part No 4H.235.15.0.00 , Intermediate Gear Support Cart Part No 4H.237.01.0.00 , Intermediate Gear Support Cart Part No 4H.237.02.0.00 , S.G.Iron Foot Cart Part No 4H.239.01.0.00 , Water Pump Sub Assembly Cart Part No 4H.242.10.0.00 , Major Overhaul Kit Cart Part No 4H.246.10.0.Sp , Major Overhaul Kit 4R1040 Cmvr Cart Part No 4H.246.20.0.Sp , Leak Off Pipe Sub Assly Cart Part No 4H.247.10.0.00 , Water Pump Assly With Pulley Cart Part No 4H.251.10.0.00 , Leak Off Pipe Sub Assly Cart Part No 4H.252.10.0.00 , Leak Off Pipe Assly: 4K1080ta Cart Part No 4H.252.30.0.00 , Inlet Exhaust Valve Pair Cart Part No 4H.253.41.0.Sp , Feed Pump Cart Part No 4H.2579.03.0.00 , Hosefor Air Cleaner 45 X 45 X 90Deg Cart Part No 4H.258.05.0.00 , Crankshaft Pulley Cart Part No 4H.261.01.0.00 , Water Pump Pulley-120 Pcd Spa Section Cart Part No 4H.262.01.0.00 , Alternator Pulley(90 Pcd) Cart Part No 4H.263.01.0.00 , Radiator Fan 17 Inch Sucker Cart Part No 4H.267.01.0.00 , Radiator Fan: 24 Pusher Cart Part No 4H.271.01.0.00 , Gasket For Turbochargerbetexhmanifold Turbocharger Cart Part No 4H.277.05.0.00 , Turbocharger Cart Part No 4H.277.10.0.00 , Monoblock Crankcase W O Bearing Cart Part No 4H.292.10.0.00 , Lube Oil Sump: Ci Btm Drain Plg Cart Part No 4H.294.02.0.00 , Baffle Plate Cart Part No 4H.294.04.0.00 , Flywheel Assembly Cart Part No 4H.295.10.0.00 , Suction Tube Assembly Cart Part No 4H.297.20.0.00 , Silencer Bracket Cart Part No 4H.301.01.0.00 , U-Clamping Stud Cart Part No 4H.301.02.0.00 , Joint: Turbo (Diffuser Side) Cart Part No 4H.302.03.0.00 , Spacer For Radiator Fan (40 Mm) Cart Part No 4H.303.02.0.00 , Wet Pm Kit (W/O Oil) For 4H.3048 Cart Part No 4H.304.8.0.Sp , Coolant Testing Kit Cart Part No 4H.307.10.0.00 , Alternator: 12V 90A Cart Part No 4H.311.02.0.00 , Plate For Fuel Filter: Inlet Mfold Cart Part No 4H.317.01.0.00 , Nozzle Leak Off Pipe Cart Part No 4H.323.10.0.00 , Suction Tube Cart Part No 4H.324.10.0.00 , High Pressure Pipe Set 700Mm Cart Part No 4H.325.10.0.00 , Pipe, Radiator To Pump Inlet Cart Part No 4H.328.01.0.00 , Hose: 45 Idx 5.2 Thk X 95L Cart Part No 4H.328.02.0.00 , Clamp Top For Water Inlet Pipe (Ltk) Cart Part No 4H.328.05.0.00 , Clamp Bottom For Water Inlet Pipe (Ltk) Cart Part No 4H.328.06.0.00 , Bush For Alternator Mounting Cart Part No 4H.329.05.0.00 , Locating Bolt: M8x35 Cart Part No 4H.329.23.0.00 , Eye Bolt (190Mm) Cart Part No 4H.329.24.0.00 , Swivel Piece Cart Part No 4H.329.26.0.00 , Locating Bolt M10 X55mm Cart Part No 4H.329.27.0.00 , Lub Oil Supply Hose Cart Part No 4H.333.01.0.00 , Fuel Filter Ctg-Duplex Type Cart Part No 4H.333.03.0.00 , Fuel Leak Off Pipe: Wire Braided Cart Part No 4H.334.02.0.00 , Flywheel Housing Cart Part No 4H.339.01.0.00 , Exhaust Manifold Cart Part No 4H.343.03.0.00 , Sealing Washer ( For M6) Cart Part No 4H.345.32.0.Pr , Inlet Manifold (Top & Fwe Opening) Cart Part No 4H.346.01.0.00 , Blanking Plate For Inlet Manifold Cart Part No 4H.346.06.0.00 , Joint: Blanking Plate Cart Part No 4H.346.07.0.00 , Inlet Manifold (Top Opening) Cart Part No 4H.346.11.0.00 , Joint: Exhaust Diffuser Cart Part No 4H.357.02.0.00 , Joint For Front Cover ( Ts 9013 ) Cart Part No 4H.358.04.0.00 , Gear End Oil Seal 80X105x12 Cart Part No 4H.358.06.0.00 , Oil Deflector Plate Cart Part No 4H.358.12.0.00 , Lube Oil Sump: Drain Plug-Fip Side Cart Part No 4H.359.01.0.00 , Joint For Lub Oil Sump Cart Part No 4H.359.02.0.00 , Hose Straight: 70Mm L Central Hump Cart Part No 4H.366.07.0.00 , Hose: Turbo Drain Pipe 170Mm Cart Part No 4H.366.08.0.00 , Hose For Turbo Drain Pipe Cart Part No 4H.366.12.0.00 , Bolt : Crank Pulley Cart Part No 4H.370.02.0.00 , Crankshaft Gear Cart Part No 4H.371.02.0.00 , Crankshaft Assly Cart Part No 4H.371.50.0.00 , Shaft: Lube Oil Pump Intermediate Gear Cart Part No 4H.372.01.0.00 , Hard Washer - Intermediate Gear Cart Part No 4H.372.02.0.00 , Cover For Fuel Pump Bore Cart Part No 4H.373.01.0.00 , O Ring: Fuel Pump Cover Cart Part No 4H.373.02.0.00 , Adaptor For Tacho Drive Unit Cart Part No 4H.375.01.0.00 , Joint: Tacho Drive Unit Adaptor Cart Part No 4H.375.02.0.00 , Injector Cart Part No 4H.376.20.0.00 , Camshaft Subassembly Cart Part No 4H.380.20.0.00 , Leak Off Pipe Assly. Cart Part No 4H.381.20.0.00 , Exhaust Manifold Cart Part No 4H.383.01.0.00 , Header (For Lo& Spin On Filter) Cart Part No 4H.385.01.0.00 , Lube Oil Cooler -12 Plates Cart Part No 4H.385.02.0.00 , Spacer: Fan Cart Part No 4H.390.01.0.00 , Water Pump Pulley 108 Pcd Cart Part No 4H.394.01.0.00 , Thermostat Housing Cart Part No 4H.395.10.0.00 , Lub Oil Sumpfor 4Wd Engine Cart Part No 4H.396.06.0.Pr , Dipstick Assembly For 4Wd Engine Cart Part No 4H.396.10.0.Pr , Exhaust Diffuser With Triangular Flange Cart Part No 4H.398.05.0.00 , Dog Bone For K24 Tc Cart Part No 4H.398.11.0.00 , Tc Housing For Dog Bone Cart Part No 4H.398.12.0.00 , Exhaust Diffuser With Triangular Flange Cart Part No 4H.398.13.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.398.14.0.00 , Plate For Fuel Filter Cart Part No 4H.399.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.399.02.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.399.03.0.00 , Raised Dipstick Assembly(350 Mm) Cart Part No 4H.401.10.0.00 , Thermostat Hsg Assembly Cart Part No 4H.402.20.0.00 , Bracket For Air Cleaner Cart Part No 4H.404.01.0.00 , Rubber Hose Cart Part No 4H.404.02.0.00 , Adapter For Air Cleaner Cart Part No 4H.404.03.0.00 , Pipe: Radiator-Pump Inlet Cart Part No 4H.405.01.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.405.02.0.00 , Hose: Make Up Water Connection Cart Part No 4H.405.03.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 4H.405.04.0.00 , Rubber Hose: Radiator Air Vent Cart Part No 4H.405.05.0.00 , Stainless Steel Hose Clip S/F 45 To 61 Mm Hose O.D. (To Replace 50519/11) Cart Part No 4H.405.06.0.00 , Stainless Steel Hose Clip S/F 35 To 41 Mm Hose O.D (To Replace 50519/08) Cart Part No 4H.405.07.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 4H.405.08.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.405.09.0.00 , Radiator Support( F.I.P. Side) Cart Part No 4H.406.01.0.00 , Radiator Support (Starter Side) Cart Part No 4H.406.02.0.00 , Stay (For Radiator) Cart Part No 4H.406.04.0.00 , Air Pipe (Turbocharger To Inlet Manifold) Cart Part No 4H.410.01.0.00 , Air Cleaner Assly: 9.5M3/M Cart Part No 4H.412.03.0.00 , Pvc Pipe For Air Cleaner (Suction Side) Cart Part No 4H.412.05.0.00 , Bracket For Air Cleaner Cart Part No 4H.412.09.0.00 , Hose For Air Cleaner Cart Part No 4H.412.32.0.Pr , Thermostat Assembly Cart Part No 4H.415.10.0.00 , Adaptor (For Temperature Gauge) Cart Part No 4H.416.01.0.00 , Alternator: 24V 55A Cart Part No 4H.422.01.0.00 , Alternator: Wo Blocking Diode Cart Part No 4H.422.02.0.00 , High Press Pipe Set 640Mm Cart Part No 4H.425.10.0.00 , Avr Programming Kit Usd2dxr Cart Part No 4H.4251.76.0.00 , Tail Pipe For 4R1190ta 82 5Kva Cpcb Iv Cart Part No 4H.429.03.0.Pr , Exhaust Flange For Pipe Outlet (8 Holes X 20 Dia X 190.5 Pcd / 230 O.D. X 110 I.D. X 116 Cart Part No 4H.429.08.0.Pr , Lifting Hookgear End Side Cart Part No 4H.433.02.0.00 , Crankshaft Assly. With Gear Cart Part No 4H.437.10.0.00 , Rubber Hose Cart Part No 4H.442.01.0.00 , Sleeve (For Air Cleaner Hose) Cart Part No 4H.442.02.0.00 , Rubber Hose Cart Part No 4H.442.03.0.00 , Hose: Air Cleaner Cart Part No 4H.442.04.0.00 , Adaptor For Lube Oil Supply Pipe Cart Part No 4H.443.02.0.00 , Joint: Adaptor (On Crankcase) For Turbo & Compr Oil Cart Part No 4H.443.07.0.00 , Lube Oil Inlet Pipe (For Compressor) Cart Part No 4H.444.01.0.00 , Adaptor For Oil Supply Pipe To Compressor Cart Part No 4H.444.02.0.00 , Lube Oil Inlet Pipe (For Compressor) Cart Part No 4H.444.03.0.00 , Joint For Exhaust Silencer With (174 Od) S/F Un Shanti Cart Part No 4H.445.08.0.00 , Rain Cap Cart Part No 4H.446.50.0.00 , Fuel Pipe Cart Part No 4H.448.36.0.00 , Fuel Cap Cart Part No 4H.448.37.0.00 , Fuel Pipe 75 Mm Length Cart Part No 4H.449.03.0.00 , Spacer For Battery Clampingi D7 O D12 Length 20 For Shanti Proj Cart Part No 4H.450.06.0.00 , Terminal Sleeve (Red) Cart Part No 4H.450.16.0.00 , Terminal Sleeve (Black) Cart Part No 4H.450.17.0.00 , Battery Cable 50 Sqmm For L3 Cold Start Cart Part No 4H.450.26.0.Pr , Battery Cable 50 Sqmm For L3 Cold Start Cart Part No 4H.450.70.0.Pr , Clamping Fasteners Assembly Cart Part No 4H.450.90.0.Pr , Water Pump Belt 3 Cart Part No 4H.465.46.0.00 , Rubber Hose: Radial Seal Air Cleaner Cart Part No 4H.471.03.0.00 , Stud Coupler (115 Mm Long) Cart Part No 4H.472.02.0.00 , Nut : M6x1lh Thread Cart Part No 4H.472.03.0.00 , Spacer ( I.D 7,O.D 13 , L 25 Mm ) Cart Part No 4H.472.04.0.00 , Spacer 7Id, 13Od & 10 Mm Long Cart Part No 4H.472.05.0.00 , Lever For Electronic Actuator Cart Part No 4H.472.07.0.00 , Bracket For Actuator Cart Part No 4H.472.09.0.00 , Spacer For Linkage Cart Part No 4H.472.13.0.00 , Lever For Electronic Actuator Cart Part No 4H.472.14.0.00 , Volt Suppressor: B12 Ecu Cart Part No 4H.472.15.0.00 , Bracket For Actuator Cart Part No 4H.472.66.0.00 , Bracket For Actuator Cart Part No 4H.472.67.0.00 , Tension Spring Cart Part No 4H.482.03.0.00 , Spring Holding Bolt Modified, Ltk Cart Part No 4H.482.09.0.00 , Bracket For Stop Lever Mounting Cart Part No 4H.482.14.0.00 , Adaptor For Fuel Inlet (Both End M14x15) Cart Part No 4H.486.01.0.00 , Adaptor M14 X M16 U Cart Part No 4H.486.05.0.00 , Leak Off Pipe Sub Assly Cart Part No 4H.486.10.0.00 , Fuel Pipe From Fuel Tank To Feed Pump Cart Part No 4H.486.103.0.Pr , Fuel Pipe Tank To Mud Filter Cart Part No 4H.486.13.0.00 , Fuel Return Pipe Cart Part No 4H.486.14.0.00 , Fuel Pipe Cart Part No 4H.486.15.0.00 , Fuel Return Pipe Cart Part No 4H.486.21.0.Pr , Drain Pipe Cart Part No 4H.486.24.0.00 , Fuel Pipe (Prefilter To Tank Unit) Cart Part No 4H.486.26.0.00 , Breather Hose Cart Part No 4H.486.33.0.00 , Fuel Return Pipe Cart Part No 4H.486.46.0.00 , Fuel Pipe Prefilter To Fip Cart Part No 4H.486.92.0.00 , Fuel Pipe (Feed Pump To Tank Unit) Cart Part No 4H.487.45.0.00 , Flange Cart Part No 4H.487.84.0.00 , Fuel Filling Hose: 36-125Kva For Skid Mounted Genset Cart Part No 4H.488.03.0.00 , Inlet And Oulet Connection For Fuel Tank Mail End Connection210 Height Cart Part No 4H.488.04.0.00 , Fuel Inlet Pipe Metailic Fip To Pre-Filter Cart Part No 4H.488.16.0.Pr , Fuel Inlet Pipe Metailic Pre Filter To Tank Cart Part No 4H.488.17.0.Pr , Fuel Hose-1 Cart Part No 4H.488.81.0.Pr , Fuel Hose-2 Cart Part No 4H.488.82.0.Pr , Fuel Pipewith Adaptor Cart Part No 4H.488.83.0.Pr , Fuel Pipe (From Tank To Nrv) Cart Part No 4H.488.84.0.Pr , Fuel Pipe (From Nrv To Pre-Filter) Cart Part No 4H.488.86.0.Pr , Kit For Electrical Fuel Feed Pump Fitment In 4K Cart Part No 4H.488.90.0.Sp , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No 4H.489.11.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 1 Cart Part No 4H.489.12.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 4H.489.14.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) Cart Part No 4H.489.15.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-3) Cart Part No 4H.489.16.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No 4H.489.18.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Cart Part No 4H.489.19.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No 4H.489.21.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No 4H.489.22.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No 4H.489.23.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No 4H.489.24.0.Pr , Adaptor (On Air Inlet Mfold, Adaptor) Cart Part No 4H.491.01.0.00 , Spacer For Control Pannel (9Mm I.D. & 15Mm O.D. 10Mm L) Cart Part No 4H.493.08.0.00 , Adaptor For Lub Oil Supply Pipem10x1m10x1 Cart Part No 4H.495.01.0.00 , Flywheel Assly With Starter Ring Cart Part No 4H.505.10.0.00 , Sub Assembly Of Suction Tube Cart Part No 4H.506.10.0.00 , Rail Hfrn16+Rsd+Plv For 4K1080tae (122.1Kw @ 2500Rpm) Cev3 Cart Part No 4H.508.03.0.Pr , Phase Sensor Pg 3 8 For 4K1080tae122 1Kw 2500Rpmcev3 Cart Part No 4H.508.06.0.Pr , Engine Speed Sensor Dg6k For 4K1080tae122 1Kw 2500Rpmcev3 Cart Part No 4H.508.07.0.00 , Engine Speed Sensor Dg6k For 4K1080tae122 1Kw 2500Rpmcev3part No 0 281 002 Cart Part No 4H.508.07.0.Pr , Temperature Sensor: 4K1080tae 122.1Kw Cart Part No 4H.508.08.0.00 , Manifold Absolute Pressure Sensor Ds S3 Tf 4Bar For 4K1080tae122 1Kw 2500Rpm Cart Part No 4H.508.09.0.00 , Injector Cart Part No 4H.508.16.0.Pr , High Pressure Pump Cb28-3L-Ohw Cart Part No 4H.508.24.0.00 , Cri Injector For Bs Iv Project300 X 142 X 7 Cart Part No 4H.508.70.0.Pr , Cri Injector For Bs Iv Project Ks Nozzle375 X 142 X 7 Cart Part No 4H.508.73.0.Pr , Manifold Absolute Pressure Sensor For Na Gas Engines Cart Part No 4H.508.81.0.Pr , Injector Leak-Off Line Retaining Ring Cart Part No 4H.508.83.0.Pr , Injector For 6K1080ta 200 Kva Cpcb4 7 X 142 X 510K 1 3He 10 5 Cart Part No 4H.508.86.0.Pr , Phase Sensor 50% Threshold For Dv Cart Part No 4H.508.91.0.Pr , Intake Manifold Pressure Temperature Sensor(140Degc)_32Mpp14-3-Env_C Cart Part No 4H.508.94.0.Pr , Joint: Exh Diffuser Cart Part No 4H.522.03.0.00 , Exhaust Difusser Cart Part No 4H.522.04.0.00 , Adaptor: Oil Supply Cart Part No 4H.527.01.0.00 , Lube Oil Supply Assly Cart Part No 4H.527.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No 4H.527.20.0.00 , Silencer Assembly Cart Part No 4H.529.21.0.Pr , Expansion Bellow Cart Part No 4H.529.24.0.Pr , V Belt : Xpb1540 Cart Part No 4H.534.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.535.02.0.00 , Fuel Pipe: M12xm14-900L Cart Part No 4H.535.03.0.00 , Fuel Pipem12 X M141400 L Cart Part No 4H.535.04.0.00 , Hose: Air Cleaner Cart Part No 4H.536.02.0.00 , Hose: Air Cleaner Cart Part No 4H.536.04.0.00 , Adopter For Alternator Mounting Cart Part No 4H.541.02.0.00 , Spacer (10.5 I.D X 20 O.D. X 23 Length / Material - En1a Or M.S.) Cart Part No 4H.541.05.0.00 , Lifting Hook Gear End Side Cart Part No 4H.544.01.0.00 , Exhaust Adaptor Cart Part No 4H.546.01.0.00 , Mcb, 1Pole, 20 Amps Cart Part No 4H.5460.56.0.00 , Mcb, 1Pole, 4 Amps Cart Part No 4H.5460.58.0.00 , Bracket For Return Spring Cart Part No 4H.548.01.0.00 , Thermostat & Housing Cart Part No 4H.550.10.0.00 , Spacer: Radiator Fan 30Mm Cart Part No 4H.554.01.0.00 , Flange Cart Part No 4H.555.22.0.Pr , Lube Oil Cooler & Header Assly Cart Part No 4H.560.10.0.00 , Lub Oil Cooler And Header Assembly Cart Part No 4H.560.30.0.Pr , Lub Oil Cooler Header Assembly Cart Part No 4H.560.40.0.Pr , Spacer: 11 Idx 24 Od X 25.5 L Cart Part No 4H.561.01.0.00 , Fuel Pumpk Element: 4R1040 Cart Part No 4H.562.10.0.00 , Controller 8610 Mk Ii Cart Part No 4H.5660.81.0.00 , Hose: Fuel Filling Cart Part No 4H.572.07.0.00 , Dipstick Assembly Cart Part No 4H.573.10.0.00 , Raised Dipstick Assly: 350Mm Cart Part No 4H.578.10.0.00 , Low Fuel Level Sensor 145Mm Cart Part No 4H.585.14.0.00 , Fuel Level Sensor Cart Part No 4H.585.16.0.Pr , Fuel Injection Pump For 4R1040t Pg Cart Part No 4H.592.10.0.00 , Fuel Injection Pump : 4R1040ta-Pg Cart Part No 4H.594.10.0.00 , Leak Off Pipe Assly Cart Part No 4H.598.10.0.00 , Avmspolybond Modelp 772 For Ace Cart Part No 4H.606.02.0.00 , Flywheel Assly Cart Part No 4H.615.10.0.00 , Crank Pulley 172 Pcd, 1 Gr,Spa Cart Part No 4H.616.01.0.00 , Mud Slinger (For P92) Cart Part No 4H.616.03.0.00 , Water Pump Pulley: 120Pcd Cart Part No 4H.618.01.0.00 , Water Pump Assly 282.5 Crs Pulley Cart Part No 4H.618.10.0.00 , Adaptor For Air Cleaner Cart Part No 4H.626.11.0.00 , Rubber Hose For Air Cleaner Cart Part No 4H.626.12.0.00 , Bracket For Air Cleaner Mounting On Inlet Manifold Cart Part No 4H.626.13.0.00 , Spacer For Air Cleaner Bracket (Od 20X Id 9 X L 52) Cart Part No 4H.626.14.0.00 , Mounting Plate For Fuel Filter Cart Part No 4H.626.15.0.00 , Bracket: Alternator Mounts Cart Part No 4H.641.03.0.00 , Hose: Air Cleaner Cart Part No 4H.643.01.0.00 , Fuel Pump: 4R1040pg Cart Part No 4H.652.10.0.00 , Expansion Bellow Cart Part No 4H.655.01.0.00 , Set Of Joints Cart Part No 4H.656.03.0.Sp , Set Of Oring (For 4H.2416/4H.3421/4H.3521 Cart Part No 4H.656.23.0.00 , Set Of Copper / Rubber Washer Cart Part No 4H.656.53.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.657.01.0.00 , Header For L.O.C & Filter S/F Water Jacket Heater Cart Part No 4H.658.01.0.00 , Bracket For Water Separator Cart Part No 4H.665.01.0.00 , Push Button ( For Heater) Cart Part No 4H.671.02.0.00 , Thermostat And Housing Assembly Cart Part No 4H.673.10.0.00 , Flywheel Housing Cart Part No 4H.682.01.0.00 , Blanking Plate For Starter Bore Cart Part No 4H.682.02.0.00 , Flange For Starter Cart Part No 4H.682.03.0.00 , Flywheel Housing Cart Part No 4H.682.04.0.00 , Starter Ring Cart Part No 4H.683.01.0.00 , Exhaust Manifold (Fwe Top Open) Cart Part No 4H.685.11.0.00 , Air Pipe(Turbo To Inlet Pipe) Cart Part No 4H.686.12.0.00 , Assly Lube Oil Inlet Pipe: K24 Tc Cart Part No 4H.687.50.0.00 , Lube Oil Drain Pipe Cart Part No 4H.687.60.0.00 , V Belt Xpa 1280 Cart Part No 4H.692.01.0.00 , V Belt Spa X 1280 X 2 Pair Cart Part No 4H.692.02.0.00 , V Belt: Spa 1300Ar Armide Wrap Cart Part No 4H.692.03.0.00 , Eye Bolt : Dia 12X 220 Long Cart Part No 4H.703.07.0.00 , Eye Bolt (Dia.12 X 220 Length) Cart Part No 4H.703.15.0.Pr , Bracket For Accelerator Cable Cart Part No 4H.715.01.0.00 , Adaptorfor Solenoid Cart Part No 4H.719.12.0.Pr , Leak Off Pipe Assembly Cart Part No 4H.719.20.0.00 , Elect Rpm Cum Hour Meter 24V Sf 172 Pcd C Pulley 90 Pcd Alt Pulley 12 Pole Altr Cart Part No 4H.723.01.0.00 , Fuel Pipe (90,14X14b-90 Deg, 700 Wb) Cart Part No 4H.739.03.0.00 , Fuel Pipe: 7.5 14X14b-90 Deg520 Wb Cart Part No 4H.739.04.0.00 , Recovery Tank With Pipe:4Rta Cart Part No 4H.760.03.0.00 , Stay Rod: Radiator Cart Part No 4H.761.02.0.00 , Aluminium Radiator Assembly Cart Part No 4H.761.95.0.Pr , Recovery Tank With Pipe (For 2R To 4R Radiators) Cart Part No 4H.762.03.0.00 , Exhaust Manifold Cart Part No 4H.763.02.0.00 , Air Pipe Tc To Inlet Mfold Cart Part No 4H.764.11.0.00 , Lube Oil Inlet Pipe Cart Part No 4H.765.02.0.Pr , Platefor Turbo Oil In Pipe Cart Part No 4H.765.03.0.Pr , Assly Lube Oil Inlet Pipe Cart Part No 4H.765.50.0.00 , L O Drain Arrangement For K24 Vs Turboterex Vectra Cart Part No 4H.765.60.0.00 , Leak Off Pipe Assembly Cart Part No 4H.769.10.0.00 , Leak Off Pipe Assly Cart Part No 4H.769.20.0.00 , Hose: Air Cleaner Cart Part No 4H.774.04.0.00 , Flange (At Silencer Inlet & Outlet) For 4R1040,4R1040t Silent Set Cart Part No 4H.775.04.0.00 , Residential Silencer For 62 5 Kva Cart Part No 4H.777.01.0.00 , Adaptor (5/8 Inch Unf X M14) Cart Part No 4H.779.01.0.00 , Thermostat & Hsg Assly Cart Part No 4H.779.10.0.00 , Thermostat And Hsg Assembly Cart Part No 4H.779.20.0.00 , Thermostat And Housing (1/2Npt-M14 Housing, 90Deg Bend Cover To Fip Side) Cart Part No 4H.779.60.0.00 , Thermostat And Hsg Assembly Cart Part No 4H.779.80.0.00 , Gear End Foot Cart Part No 4H.781.01.0.00 , Gear End Foot Cart Part No 4H.781.02.0.00 , Nylock Nut For Jcb Loging (M8x1.25) Cart Part No 4H.781.11.0.00 , Nylock Nut(M14x 2) Cart Part No 4H.781.13.0.00 , Drain Pipe For Lube Oil Sump Cart Part No 4H.790.07.0.00 , Hose: Air Cleaner Cart Part No 4H.791.03.0.00 , Exhaust Silencer Cart Part No 4H.792.40.0.00 , Exhaust Silencer Set: 82.5Kva Cart Part No 4H.792.50.0.00 , Exhaust Silencer Cart Part No 4H.792.60.0.00 , Exhaust Manifold (Ge, Top Open) Cart Part No 4H.793.11.0.00 , Flexible Rubber Coupling Cart Part No 4H.807.06.0.Pr , Sae 2De Brkt- Prot. Screen Asly -Kg34. Kva Rating:- (45-62.5, 1Ph & 82.5-160, 3Ph) Cart Part No 4H.837.03.0.Asp , Excitor Stator Kg34 H=55Mm 8P. Kva Rating:- (45-62.5, 1Ph & Cart Part No 4H.837.04.0.Asp , Exciter Rotor Cart Part No 4H.837.05.0.Asp , Fan Assembly Kg34kva Rating45 62 51Ph Cart Part No 4H.837.06.0.Asp , Drain Pipe For Lub Oil Sump Cart Part No 4H.844.02.0.00 , Emergency Push Stop Button Cart Part No 4H.851.02.0.00 , Emergency Stop Push Button Tunr To Relesenc Elment Cart Part No 4H.851.11.0.00 , Power Terminal Board Cart Part No 4H.863.14.0.00 , Relay Board Cart Part No 4H.864.02.0.00 , Relay Board: 4 Relay Cart Part No 4H.865.01.0.00 , Fuse Holder With Fuse Blown Indicator Cart Part No 4H.865.08.0.00 , Glass Fuse 2Amp20 Mm Cart Part No 4H.865.09.0.00 , Single Pole Mcb 32A Cart Part No 4H.865.16.0.00 , Selector Switch Cart Part No 4H.865.17.0.00 , Control Terminal 6 Sq.Mm,600V,50A,Type Cart Part No 4H.865.22.0.00 , Power Terminal Board 125 Amp.4 Way 8 Mm Stud Cart Part No 4H.865.23.0.00 , Relay Board 2 & 1/2 12V Dc Cart Part No 4H.865.27.0.00 , Relay Board (4 Relay ) Contact Raiting 5 Amp.12 V Dc 1 C/Owith Relay. Cart Part No 4H.865.33.0.00 , Earthing Cable (Braded) 6Mm Dia. With Suitable Lug. Alt. To Base Plate For50 & 72 Cart Part No 4H.872.03.0.00 , Mccb 200A,3 Pole Cart Part No 4H.873.01.0.00 , Battery Charger - 6A 12V Cart Part No 4H.878.07.0.00 , 2A Electrical Charger Cart Part No 4H.878.12.0.00 , 12V, 2A, Battery Charger, 15Kv Common Mode Surge Isolation Cart Part No 4H.878.14.0.Pr , Egt Inlet Outlet Joint Cart Part No 4H.881.01.0.Pr , Ad Blue Tank Clamp (25Lits) Cart Part No 4H.881.03.0.Pr , Vdo Sensor Assembly Cart Part No 4H.890.40.0.00 , Fuel Pipe: M14xm14b Parallel 750L Cart Part No 4H.896.07.0.00 , Fuel Pipe: M14xm14 Banjo With 60 Deg, 370 L, 9.5 Id Cart Part No 4H.896.08.0.00 , Fuel Pipe Inlet: M14xm14 Banjo Both Side 900L Cart Part No 4H.896.09.0.00 , Spacer For Air Cleaner Bracket (Od 20X Id 9 X L 39) Cart Part No 4H.899.02.0.00 , Hose: Air Cleaner Cart Part No 4H.899.03.0.00 , Sleeve For Air Cleaner Hose Cart Part No 4H.899.04.0.00 , Rubber Hose: K24 Tc Cart Part No 4H.899.11.0.00 , Engine Wiring Harness Assembly For Paver Application Bsiii Cart Part No 4H.900.30.0.00 , Koel Green Alternatorkg 125 S T Framel Kg 44 3 Dsae 2 11 5 415V50 Hz0 8 Pf Cart Part No 4H.901.05.0.Pr , Koel Green Alternatorcoastalhumid Environment Kg 125 S T Framekg 44 3 D1 Cart Part No 4H.901.08.0.Pr , Koel Green Alternator40kva Kg32 1L4css Frame Msae 3 Vol 11 5230V50hz0 8 P Cart Part No 4H.901.11.0.Pr , Koel Green Alternator40kva St Frame Mkg32 2S4csae3 Vol 11 5415V50hz 0 8 P Cart Part No 4H.901.12.0.Pr , Koel Green Alternator, 45Kva, St Frame:M, Kg32 2S4c, Sae3 Vol 11.5, 415V, 50Hz, 0.8 P. Cart Part No 4H.901.14.0.Pr , Wiring Harness: 4R1040 Cart Part No 4H.905.20.0.00 , Relay 12Vdc100a Model Bgr 256 Cart Part No 4H.906.11.0.00 , Wiring Harness Assembly 4R1040ta Cart Part No 4H.906.70.0.00 , Coolant Temp Switch 95 +1/-3 Deg Cart Part No 4H.907.01.0.00 , Coolant Temp Switch 1041 3 Deg Cart Part No 4H.907.03.0.00 , Wiring Harness Assembly For Kpcl With Etr Type Sol. Cart Part No 4H.924.30.0.00 , Injector Cart Part No 4H.933.02.0.00 , Injector Cart Part No 4H.933.04.0.00 , Fuel Injection Pump 4R1040na Engine (76Hp @ 2200Rpm) Cart Part No 4H.933.10.0.00 , Fuel Injection Pump For 4R1040na49 Hp 2200 Rpmwith Stop Leverbs Iii Industrial Cart Part No 4H.933.35.0.Pr , Lube Oil Sump Fabricated (35 Deg, 265 Ht, Drain Plug On Fwe & Ge Both)) Cart Part No 4H.940.01.0.00 , Lub Oil Sump Fabricated (30 Deg S/F Jcb Vmt 850 ) Cart Part No 4H.940.02.0.00 , Sub Assembly Of Suction Tube Cart Part No 4H.941.10.0.00 , Cover Plate For Flywheel Housing Cart Part No 4H.944.02.0.00 , Flywheel Assembly Cart Part No 4H.947.10.0.00 , Flywheel Assembly Cart Part No 4H.947.20.0.00 , Washer For Weld Stud M5 Cart Part No 4H.948.96.0.00 , Crankpulley Holding Spanner Cart Part No 4H.950.04.0.00 , Lseries 43Mm Integrated Mixer With Throttle Body Cart Part No 4H.956.03.0.00 , Communication Cable L Series Rs232 Communications Assembly Cart Part No 4H.956.032.0.Sp , Spark Plug : Size M12 Cart Part No 4H.956.05.0.00 , 26941102 A Lucas Distributor Cart Part No 4H.956.12.0.00 , Ht Cable Set Cart Part No 4H.956.13.0.00 , Distributor Ignition Coil 26941094A Cart Part No 4H.956.15.0.00 , R 600Z Zpr Zero Pressure Regulator Cart Part No 4H.956.39.0.00 , Sealed Ball Bearing: Deep Groove Single Row Cart Part No 4H.956.44.0.00 , Gasket For L-Series Governor Mounting Cart Part No 4H.956.59.0.00 , Pipe G I Braided1 5 Meter Long For The Gas Supply From The Solenoid Valve To Ze Cart Part No 4H.956.83.0.00 , Adaptor 1Bsp To 3 4Bsp Cart Part No 4H.956.84.0.00 , L-Series (25Mm) Integrated Mixer With Throttle Body(8404- Cart Part No 4H.956.98.0.00 , Timing Pointer Cart Part No 4H.964.01.0.00 , Set Bolt M8 ( Rolled Brass) For Panel Earthing Cart Part No 4H.971.18.0.00 , M8 Nut Rolled Brass For Panel Earthing Shanti Project Cart Part No 4H.971.19.0.00 , M8 Brass Washer For Panel Earthing Cart Part No 4H.971.23.0.00 , Expansion Bellow Cart Part No 4H.973.10.0.00 , Canopy Wiring Harness For 125Kva 4K Cpcb4+ Cart Part No 4H.978.80.0.Pr , Breather Pipe Cart Part No 4H.979.06.0.00 , B12 Ecu 40Kva Appl Cart Part No 4H.985.12.0.00 , Wiring Harness Assly: Cpcb Cart Part No 4H.986.20.0.00 , Battery Cable 50 Sq Mm For 24V System Cart Part No 4H.996.20.0.Pr , Cambush Pressing Tool Cart Part No 4H.998.32.0.Tol , Core Plug Pressing Tool Cart Part No 4H.998.33.0.Tol , Deflector Plate Guide Cart Part No 4H.998.34.0.Tol , Nozzle Puller Cart Part No 4H.998.35.0.Tol , Piston Guide Cart Part No 4H.998.36.0.Tol , Stem Seal Cart Part No 4H.998.37.0.Tol , Valve Spring Tool Cart Part No 4H.998.38.0.Tol , Oil Seal Fwe Tool Cart Part No 4H.998.39.0.Tol , Liner Installation Tool Cart Part No 4H.998.40.0.Tol , Core Plug 52Mm No Cart Part No 4H.998.41.0.Tol , Liner Puller Original No Cart Part No 4H.998.42.0.Tol , Gear End Oil Seal Mandril No Cart Part No 4H.998.43.0.Tol , Wet Pm Kit (W/O Oil) For 4H.2401... - 4R1040t Cart Part No 4H.999.09.0.Sp , Cold Start Kit L3 For 4K Cart Part No 4H.999.120.0.00 , Wet Pm Kit (W/O Oil) For 4H.3501 - 4R1080 Cart Part No 4H.999.13.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3445 - 4R1040t Cart Part No 4H.999.16.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3523,4H.3545,4H.3555,4H.3558, 4H.8905, 4H.8932- 4R1040ta G1 Cart Part No 4H.999.19.0.Sp , Wet Pm Kit (W/O Oil) For 4H.6001,4H.7902 - 4K 1080Ta Cart Part No 4H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 4H.7922 - 4K1080ta G2 Cart Part No 4H.999.24.0.Sp , Set Of Joints Cart Part No 4H.999.30.0.Sp , 4R1040 Cpcb Ii Service Kit - B Check Cart Part No 4H.999.35.0.00 , 4R1040 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 4H.999.36.0.00 , Wet Pm Kit (W/O Oil) For 4H.5001, 4H.5006 - 4R1080 Cart Part No 4H.999.37.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3045,4H.3048- 4R1040 Cart Part No 4H.999.47.0.Sp , Half Overhaul Kit 4R1040 Indl Cart Part No 4H.999.50.0.00 , Wet Pm Kit (W/O Oil) For 4H.3023, 4H.3017, 4H.3002, 4H.2002- 4R1040 Cart Part No 4H.999.54.0.Sp , Major Overhaul Kit 4R1040 Bsiii Cat, Cnh, Ecel, Ace, Atlas Application Engines Cart Part No 4H.999.60.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3420, 4H.3401- 4R1040t Cart Part No 4H.999.61.0.Sp , Wet Pm Kit (W/O Oil ) For 4H.8041 Cart Part No 4H.999.62.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3031, 4H.3025 - 4R1040 Cart Part No 4H.999.64.0.Sp , Major Oh Kit 4R1040 Bsiii Terex, Apollo, Ecel, Ajax Application Engines Cart Part No 4H.999.70.0.Sp , Solenoid Valve S-0106 Cart Part No 4H.999.71.0.Sp , Pressure Regulator First Level For 62.5 Kva (R 4601) Cart Part No 4H.999.73.0.Sp , Zpr 1 Bsp (F) (R 6301) Cart Part No 4H.999.74.0.Sp , Wet Pm Kit (W/O Oil) For 4H.2501 - 4R1040 Ta Cart Part No 4H.999.75.0.Sp , Wet Pm Kit (W/O Oil) For 4H.7901, 4H.7902, 4H.7905 - 4K1080ta G2 Cart Part No 4H.999.76.0.Sp , Service Kit 500 Hrs: 4R1040 Bsiii Indl Cart Part No 4H.999.80.0.00 , Air Filter Kit A-4R1040 Bs3 Indl Cart Part No 4H.999.85.0.00 , Air Filter Kit B -4R1040 Bs3 Indl Cart Part No 4H.999.90.0.00 , Doc Catalyst (7.5 Dia X 5 Length, 15 G/Cft, 5/1 Pt:Pd, Fresh) Cart Part No 4H.Egt4.10.0.Pr , Scr Catalyst First Brick - Fresh (7.5 Dia X 7 Length, Wcl 2.5 G/In3) Cart Part No 4H.Egt4.14.0.Pr , Scr Catalyst Second Brick - Fresh (7.5 Dia X 7 Length, 2.1 G/In3 On 5” Length, Asc 2 Cart Part No 4H.Egt4.16.0.Pr , 7.5 V Band Clamp (Docto Mixer)_82601021 Cart Part No 4H.Egt4.21.0.Pr , 7 5Gasket Doc To Mixer 82544598 Cart Part No 4H.Egt4.22.0.Pr , Dosing Module B444 606 505Dm2 2 3 Hole5 Bar Cart Part No 4H.Egt4.23.0.Pr , Adblue Levelquality Temp Sensor For 25 Ltr Tank Cart Part No 4H.Egt4.26.0.Pr , 7.5 Egt System Assembly (Cpcb 4+ ) Cart Part No 4H.Egt4.61.0.Sp , Buzzerwithlamp,12Vac/Dc Cart Part No 4H.M821.26.0.Pr , Split Cotter Pin 3 2X22 Cart Part No 50.001.04.022. , Set Bolt - M5x0.8X25- 8.8 Cart Part No 50.002.05.025. , Set Bolt - M6x1x35 - 8.8 Cart Part No 50.002.06.035. , Set Bolt - M6x1x40 - 8.8 Cart Part No 50.002.06.040. , Set Bolt - M6x1x50 - 8.8 Cart Part No 50.002.06.050. , Set Bolt M6x1x60 8 8 Cart Part No 50.002.06.060. , Set Bolt - M8x1.25X16 - 8.8 Cart Part No 50.002.08.016. , Set Bolt - M8x1.25X25 - 8.8 Cart Part No 50.002.08.025. , Set Bolt - M8x1.25X30 - 8.8 Cart Part No 50.002.08.030. , Set Bolt : M8x1.25X35 -8.8 Cart Part No 50.002.08.035. , Set Bolt - M8x1.25X40 - 8.8 Cart Part No 50.002.08.040. , Set Bolt : M8x1.25X45 - 8.8 Cart Part No 50.002.08.045. , Set Bolt - M8x1.25X50 - 8.8 Cart Part No 50.002.08.050. , Set Bolt - M8x1.25X55 - 8.8 Cart Part No 50.002.08.055. , Set Bolt - M8x1.25X60 - 8.8 Cart Part No 50.002.08.060. , Set Bolt - M8x1.25X65 - 8.8 Cart Part No 50.002.08.065. , Set Bolt: M8x1.25X70 -8.8 Cart Part No 50.002.08.070. , Set Bolt - M8x1.25X75 - 8.8 Cart Part No 50.002.08.075. , Set Bolt - M8x1.25X80 - 8.8 Cart Part No 50.002.08.080. , Set Bolt - M8x1.25X85 - 8.8 Cart Part No 50.002.08.085. , Set Bolt - M8x1.25X90 - 8.8 Cart Part No 50.002.08.090. , Set Bolt - M8x1.25X95 - 8.8 Cart Part No 50.002.08.095. , Set Bolt: M8x1.25X100 -8.8 Cart Part No 50.002.08.100. , Set Bolt - M8x1.25X105 - 8.8 Cart Part No 50.002.08.105. , Set Bolt - M8x1.25X110 - 8.8 Cart Part No 50.002.08.110. , Set Bolt - M8x1.25X115 - 8.8 Cart Part No 50.002.08.115. , Set Bolt - M8x1.25X120 - 8.8 Cart Part No 50.002.08.120. , Set Bolt - M8x1.25X125 - 8.8 Cart Part No 50.002.08.125. , Hexagonal Headed Bolt - M8 X 130L Cart Part No 50.002.08.130. , Set Bolt - M8x1.25X140 - 8.8 Cart Part No 50.002.08.140. , Set Bolt M8x1 25X150 8 8 Cart Part No 50.002.08.150. , Set Bolt - M10x1.5X20 - 8.8 Cart Part No 50.002.10.020. , Set Bolt - M10x1.5X25 - 8.8 Cart Part No 50.002.10.025. , Set Bolt - M10x1.5X30 - 8.8 Cart Part No 50.002.10.030. , Set Bolt - M10x1.5X35 - 8.8 Cart Part No 50.002.10.035. , Set Bolt - M10x1.5X40 - 8.8 Cart Part No 50.002.10.040. , Set Bolt - M10x1.5X45 - 8.8 Cart Part No 50.002.10.045. , Set Bolt - M10x1.5X50 - 8.8 Cart Part No 50.002.10.050. , Set Bolt - M10x1.5X55 - 8.8 Cart Part No 50.002.10.055. , Set Bolt - M10x1.5X60 - 8.8 Cart Part No 50.002.10.060. , Set Bolt - M10x1.5X65 - 8.8 Cart Part No 50.002.10.065. , Set Bolt - M10x1.5X70 - 8.8 Cart Part No 50.002.10.070. , Set Bolt - M10x1.5X75 - 8.8 Cart Part No 50.002.10.075. , Set Bolt - M10x1.5X80 - 8.8 Cart Part No 50.002.10.080. , Set Bolt - M10x1.5X85 - 8.8 Cart Part No 50.002.10.085. , Set Bolt - M10x1.5X90 - 8.8 Cart Part No 50.002.10.090. , Set Bolt - M10x1.5X100 - 8.8 Cart Part No 50.002.10.100. , Set Bolt - M10x1.5X110 - 8.8 Cart Part No 50.002.10.110. , Set Bolt - M10x1.5X115 - 8.8 Cart Part No 50.002.10.115. , Set Bolt - M10x1.5X120 - 8.8 Cart Part No 50.002.10.120. , Set Bolt - M10x1.5X125 - 8.8 Cart Part No 50.002.10.125. , Set Bolt - M10x1.5X130 - 8.8 Cart Part No 50.002.10.130. , Set Bolt - M10x1.5X140 - 8.8 Cart Part No 50.002.10.140. , Set Bolt - M10x1.5X150 - 8.8 Cart Part No 50.002.10.150. , Set Bolt : M10x1.5X160 -8.8 Cart Part No 50.002.10.160. , Set Bolt - M12x1.75X30 - 8.8 Cart Part No 50.002.12.030. , Set Bolt M12x1 75X35 8 8 Cart Part No 50.002.12.035. , Set Bolt - M12x1.75X40 - 8.8 Cart Part No 50.002.12.040. , Set Bolt - M12x1.75X45 - 8.8 Cart Part No 50.002.12.045. , Set Bolt - M12x1.75X50 - 8.8 Cart Part No 50.002.12.050. , Set Bolt - M12x1.75X55 - 8.8 Cart Part No 50.002.12.055. , Set Bolt - M12x1.75X60 - 8.8 Cart Part No 50.002.12.060. , Set Bolt - M12x1.75X65 - 8.8 Cart Part No 50.002.12.065. , Set Bolt - M12x1.75X70 - 8.8 Cart Part No 50.002.12.070. , Set Bolt - M12x1.75X90 - 8.8 Cart Part No 50.002.12.090. , Set Bolt - M12x1.75X100 - 8.8 Cart Part No 50.002.12.100. , Set Bolt M12x1 75X120 8 8 Cart Part No 50.002.12.120. , Set Bolt M12x1 75X125 8 8 Cart Part No 50.002.12.125. , Set Bolt - M12x1.75X150 - 8.8 Cart Part No 50.002.12.150. , Set Bolt - M12x1.75X160 - 8.8 Cart Part No 50.002.12.160. , Set Bolt - M12x1.75X200 - 8.8 Cart Part No 50.002.12.200. , Set Bolt - M14x2x45 - 8.8 Cart Part No 50.002.14.045. , Set Bolt - M14x2x50 - 8.8 Cart Part No 50.002.14.050. , Set Bolt - M14x2x60 - 8.8 Cart Part No 50.002.14.060. , Set Bolt M14 X 75 Cart Part No 50.002.14.075. , Set Bolt - M16x2x40 - 8.8 Cart Part No 50.002.16.040. , Set Bolt - M16x2x45 - 8.8 Cart Part No 50.002.16.045. , Set Bolt - M16x2x50 - 8.8 Cart Part No 50.002.16.050. , Set Bolt - M20x2.5X60 - 8.8 Cart Part No 50.002.20.060. , Set Bolt - M20x2.5X70 - 8.8 Cart Part No 50.002.20.070. , Set Bolt - M20x2.5X75 - 8.8 Cart Part No 50.002.20.075. , Hexagonal Headed Bolt - M4 X 12L Cart Part No 50.003.04.012. , Hexagonal Headed Bolt - M4 X 16L Cart Part No 50.003.04.016. , Set Screw - M5x0.8X10 - 8.8 Cart Part No 50.003.05.010. , Screw M5 X 16 Mm Cart Part No 50.003.05.016. , Set Screw - M5x0.8X20 - 8.8 Cart Part No 50.003.05.020. , Set Screw - M6x1x10 - 8.8 Cart Part No 50.003.06.010. , Set Screw: M6x1x12 -8.8 Cart Part No 50.003.06.012. , Set Screw - M6x1x14 - 8.8 Cart Part No 50.003.06.014. , Set Screw - M6x1x15 - 8.8 Cart Part No 50.003.06.015. , Set Screw: M6x1x16 -8.8 Cart Part No 50.003.06.016. , Set Screw M6x1x18 8 8 Cart Part No 50.003.06.018. , Set Screw - M6x1x20 - 8.8 Cart Part No 50.003.06.020. , Set Screw Cart Part No 50.003.06.022. , Set Screw - M6x1x25 - 8.8 Cart Part No 50.003.06.025. , Set Screw - M6x1x30 - 8.8 Cart Part No 50.003.06.030. , Set Screw - M6x1x35 - 8.8 Cart Part No 50.003.06.035. , Set Screw - M6x1x40 - 8.8 Cart Part No 50.003.06.040. , Set Screw Cart Part No 50.003.06.045. , Set Screw - M6x1x50 - 8.8 Cart Part No 50.003.06.050. , Set Screw - M6 X O60 Long Cart Part No 50.003.06.060. , Set Screw - M8x1.25X10 - 8.8 Cart Part No 50.003.08.010. , Set Screw - M8x1.25X14 - 8.8 Cart Part No 50.003.08.014. , Set Screw - M8x1.25X15 - 8.8 Cart Part No 50.003.08.015. , Set Screw: M8x1.25X16 -8.8 Cart Part No 50.003.08.016. , Set Screw - M8x1.25X18 - 8.8 Cart Part No 50.003.08.018. , Set Screw: M8x1.25X20 -8.8 Cart Part No 50.003.08.020. , Set Screw - M8x1.25X22 - 8.8 Cart Part No 50.003.08.022. , Set Screw: M8x1.25-8.8 Cart Part No 50.003.08.025. , Set Screw: M8x1.25X30-8.8 Cart Part No 50.003.08.030. , Set Screw - M8x1.25X35 - 8.8 Cart Part No 50.003.08.035. , Set Screw M8x1 25X40 8 8 Cart Part No 50.003.08.040. , Set Screw - M8x1.25X45 - 8.8 Cart Part No 50.003.08.045. , Set Screw - M8x1.25X50 - 8.8 Cart Part No 50.003.08.050. , Set Screw - M8x1.25X55 - 8.8 Cart Part No 50.003.08.055. , Set Screw M8x1.25X60 Cart Part No 50.003.08.060. , Set Screw Cart Part No 50.003.08.080. , Set Screw - M10x1.5X15 - 8.8 Cart Part No 50.003.10.015. , Set Screw: M10x1.5X20 -8.8 Cart Part No 50.003.10.020. , Set Screw: M10x1.5X25 -8.8 Cart Part No 50.003.10.025. , Set Screw: M10x1.5X30 -8.8 Cart Part No 50.003.10.030. , Set Screw: M10x1.5X35 -8.8 Cart Part No 50.003.10.035. , Set Screw - M10x1.5X40 - 8.8 Cart Part No 50.003.10.040. , Set Screw - M10x1.5X45 - 8.8 Cart Part No 50.003.10.045. , Set Screw - M10x1.5X50 - 8.8 Cart Part No 50.003.10.050. , Set Screw - M10x1.5X55 - 8.8 Cart Part No 50.003.10.055. , Set Screw - M10x1.5X70 - 8.8 Cart Part No 50.003.10.070. , Set Screw - M12x1.75X20 - 8.8 Cart Part No 50.003.12.020. , Set Screw - M12x1.75X25 - 8.8 Cart Part No 50.003.12.025. , Set Screw - M12x1.75X30 - 8.8 Cart Part No 50.003.12.030. , Set Screw - M12x1.75X35 - 8.8 Cart Part No 50.003.12.035. , Set Screw - M12x1.75X40 - 8.8 Cart Part No 50.003.12.040. , Set Screw - M12x1.75X45 - 8.8 Cart Part No 50.003.12.045. , Set Screw - M12x1.75X50 - 8.8 Cart Part No 50.003.12.050. , Set Screw - M12x1.75X55 - 8.8 Cart Part No 50.003.12.055. , Set Screw Cart Part No 50.003.12.060. , Set Screw M14x2x30 8 8 Cart Part No 50.003.14.030. , Set Screw M14x2x35 8 8 Cart Part No 50.003.14.035. , Set Screw - M14x2x40 - 8.8 Cart Part No 50.003.14.040. , Set Screw - M14x2x50 - 8.8 Cart Part No 50.003.14.050. , Set Screw - M14x2x55 - 8.8 Cart Part No 50.003.14.055. , Set Screw - M16x2x40 - 8.8 Cart Part No 50.003.16.040. , Set Screw - M16x2x50 - 8.8 Cart Part No 50.003.16.050. , Set Screw - M20x2.5X50 - 8.8 Cart Part No 50.003.20.050. , Set Screw - M20x2.5X60 - 8.8 Cart Part No 50.003.20.060. , Nut - M4x0.7 - Gr.8.8 Cart Part No 50.006.04.000. , Nut - M5x0.8 - Gr.8.8 Cart Part No 50.006.05.000. , Nut: M6x1 - Gr8 Cart Part No 50.006.06.000. , Nut M8x1.25 -Gr8 Cart Part No 50.006.08.000. , Nut : M10x1.5 -Gr8 Cart Part No 50.006.10.000. , Nut: M12x1.75 - Gr8 Cart Part No 50.006.12.000. , Nut - M14x2 - Gr.8.8 Cart Part No 50.006.14.000. , Nut - M16x2 - Gr.8.8 Cart Part No 50.006.16.000. , Nut M18x2 5 Gr 8 8 Cart Part No 50.006.18.000. , Nut - M20x2.5 - Gr.8 Cart Part No 50.006.20.000. , Nut M8x1 Gr 8 Cart Part No 50.007.08.000. , Nut - M16x1.5 - Gr.8 Cart Part No 50.007.16.000. , Lock Nut - M6x1 - Gr.8 Cart Part No 50.008.06.000. , Lock Nut - M10x1.5 - Gr.8 Cart Part No 50.008.10.000. , Nut Cart Part No 50.009.10.000. , Lock Nut - M14x1.5 - Gr.8 Cart Part No 50.009.14.000. , Lock Nut 20X1.5 Cart Part No 50.009.20.000. , Stud - M6x1x16 - 8.8 Cart Part No 50.010.06.016. , Stud - M6x1x20 - 8.8 Cart Part No 50.010.06.020. , Stud - M6x1x35- 8.8 Cart Part No 50.010.06.035. , Stud - M8x1.25X16 - 8.8 Cart Part No 50.010.08.016. , Stud - M8x1.25X20 - 8.8 Cart Part No 50.010.08.020. , Stud: M8x1.25X25 - 8.8 Cart Part No 50.010.08.025. , Stud -M8x 1.25X30 -8.8 Cart Part No 50.010.08.030. , Stud: M8x1.25X35 -8.8 Cart Part No 50.010.08.035. , Stud-M8x1.25X40 -8.8 Cart Part No 50.010.08.040. , Stud: M8x1.25X45 -8.8 Cart Part No 50.010.08.045. , Stud: M8x1.25X50 - 8.8 Cart Part No 50.010.08.050. , Stud-M8x1.25X55 -8.8 Cart Part No 50.010.08.055. , Stud: M8x1.25X60 - 8.8 Cart Part No 50.010.08.060. , Stud- M8 X1.25 X 65 Mm - 8.8 Grade Cart Part No 50.010.08.065. , Stud: M8x1.25X75 - 8.8 Cart Part No 50.010.08.075. , Stud - M8x1.25X80 - 8.8 Cart Part No 50.010.08.080. , Stud - M8x1.25X85 - 8.8 Cart Part No 50.010.08.085. , Stud M8x1.25X090 Gr. 8.8 Cart Part No 50.010.08.090. , Stud - M8x1.25X95 - 8.8 Cart Part No 50.010.08.095. , Stud Cart Part No 50.010.08.100. , Stud: M10x1.5X25 - 8.8 Cart Part No 50.010.10.025. , Stud-M8x1.25X55 -8.8 Cart Part No 50.010.10.030. , Stud: M10x1.5X35 - 8.8 Cart Part No 50.010.10.035. , Stud: M10x1.5X45 -8.8 Cart Part No 50.010.10.045. , Stud: M10x1.5X50 - 8.8 Cart Part No 50.010.10.050. , Stud - M10x1.5X60 - 8.8 Cart Part No 50.010.10.060. , Stud - M10x1.5X65 - 8.8 Cart Part No 50.010.10.065. , Stud - M10x1.5X70 - 8.8 Cart Part No 50.010.10.070. , Stud: M10x1.5X75 - 8.8 Cart Part No 50.010.10.075. , Stud Cart Part No 50.010.10.110. , Stud M12x1 75X25 8 8 Cart Part No 50.010.12.025. , Stud - M12x1.75X30 - 8.8 Cart Part No 50.010.12.030. , Stud Cart Part No 50.010.12.150. , Stud - M12x1.75X200 - 8.8 Cart Part No 50.010.12.200. , Socket Head Screw - M6x1x14 - 8.8 Cart Part No 50.011.06.014. , Socket Head Screw - M6x1x16 - 8.8 Cart Part No 50.011.06.016. , Socket Head Screw - M6x1x20 - 8.8 Cart Part No 50.011.06.020. , Socket Head Screw - M6x1x25 - 8.8 Cart Part No 50.011.06.025. , Socket Head Screw M6x1x30 Cart Part No 50.011.06.030. , Socket Head Screw: M8x1.25X16-8.8 Cart Part No 50.011.08.016. , Socket Head Screw M8x1.25X20 -8.8 Cart Part No 50.011.08.020. , Socket Head Screw - M8x1.25X25 - 8.8 Cart Part No 50.011.08.025. , Socket Head Screw - M8x1.25X30 - 8.8 Cart Part No 50.011.08.030. , Socket Head Screw - M8x1.25X35 - 8.8 Cart Part No 50.011.08.035. , Socket Head Screw - M8x1.25X40 - 8.8 Cart Part No 50.011.08.040. , Socket Head Screw M8x1 25X45 8 8 Cart Part No 50.011.08.045. , Socket Head Cap Bolt(M8x50 Long) Cart Part No 50.011.08.050. , Socket Head Screw - M8x1.25X55 - 8.8 Cart Part No 50.011.08.055. , Socket Head Cap Bolt M8x60 Lg Cart Part No 50.011.08.060. , Socket Head Screw - M8x1.25X70 - 8.8 Cart Part No 50.011.08.070. , Socket Head Screw: M8x1.25X75-8.8 Cart Part No 50.011.08.075. , Socket Head Screw - M8x1.25X90 - 8.8 Cart Part No 50.011.08.090. , Socket Head Screw - M10x1.5X20 - 8.8 Cart Part No 50.011.10.020. , Socket Head Screw - M10x1.5X25 - 8.8 Cart Part No 50.011.10.025. , Socket Head Screw - M10x1.5X30 - 8.8 Cart Part No 50.011.10.030. , Socket Head Screw M10x1 5X35 8 8 Cart Part No 50.011.10.035. , Socket Head Screw - M10x1.5X40 - 8.8 Cart Part No 50.011.10.040. , Socket Head Screw - M10x1.5X50 - 8.8 Cart Part No 50.011.10.050. , Socket Head Screw - M10x1.5X120 - 8.8 Cart Part No 50.011.10.120. , Socket Head Screw - M12x1.75X40 - 8.8 Cart Part No 50.011.12.040. , Set Bolt - 5/16 Inch Bsfx2 Inch Long - 8.8 Cart Part No 50.013.02.014. , Set Bolt - 5/16 Inch Bsfx2-3/4 Inch Long - 8.8 Cart Part No 50.013.02.017. , Set Bolt - 5/16 Inch Bsfx3.0 Inch Long - 8.8 Cart Part No 50.013.02.018. , Set Bolt - 3/8Bsfx1-5/8L - 8.8 Cart Part No 50.013.03.012. , Set Screw - 5/16Bsfx5/8L - 8.8 Cart Part No 50.014.02.004. , Set Screw - 5/16Bsfx1L - 8.8 Cart Part No 50.014.02.007. , Set Screw - 5/16Bsfx1-1/2L - 8.8 Cart Part No 50.014.02.011. , Nut - 5/16 Bsf Normal Class - Grade P Cart Part No 50.015.02.000. , Lock Nut - 5/16Bsf Normal Class - Gr.P Cart Part No 50.016.02.000. , Lock Nut - 1/2Bsf Normal Class - Gr.P Cart Part No 50.016.05.000. , Socket Head Grub Screw Cart Part No 50.022.03.006. , Socket Head Grub Screw - M6 X 08 Cart Part No 50.022.06.008. , Slotted Cheese Head Screw - M3x16 Cart Part No 50.025.03.016. , Slotted Cheese Head Screw M5x15 Cart Part No 50.025.05.015. , Stud 5/16Bsfx1.1/8 Grade R Cart Part No 50.030.02.004. , Stud 5/16Bsfx1.1/2 Grade R Cart Part No 50.030.02.007. , Split Cotter Pin - 1/16X1/2 Cart Part No 50.036.03.001. , Split Cotter Pin - 1/8X1-1/2 Cart Part No 50.036.07.010. , Self Locking Nyloc Nut - M5 Cart Part No 50.037.05.000. , Self Locking Nyloc Nut - M6 Cart Part No 50.037.06.000. , Self Locking Nyloc Nut - M8 Cart Part No 50.037.08.000. , Self Locking Nyloc Nut - M16 Cart Part No 50.037.16.000. , Wing Nut M6 Cart Part No 50.047.05.000. , Screw Cart Part No 50.051.12.035. , Set Screw: M12x1.75X 50L - 10.9 Cart Part No 50.051.12.050. , Set Screw 10.9 Class Cart Part No 50.051.16.050. , Set Screw 10.9 Grade Cart Part No 50.051.16.070. , Set Bolt-M10x30-10.9 Cart Part No 50.052.10.030. , Set Bolt M10x35 10 9 Cart Part No 50.052.10.035. , Bolt 10X80 10.9 Grade Cart Part No 50.052.10.080. , Set Bolt-M12x30-10.9 Cart Part No 50.052.12.030. , Set Bolt: M12 X 45 - 10.9 Cart Part No 50.052.12.045. , Set Bolt-M12x65-10.9 Cart Part No 50.052.12.065. , Set Bolt M14gr.10.9 Cart Part No 50.052.14.045. , Set Bolt: M14 X 80 Cart Part No 50.052.14.080. , Set Bolt Cart Part No 50.052.14.100. , Set Bolt-M16x150-10.9 Cart Part No 50.052.16.150. , Set Bolt-M20x60-10.9 Cart Part No 50.052.20.060. , Headless Pipe Plug1/8-27 Nptf Cart Part No 50.056.02.000. , Headless Pipe Plug1/2-14 Nptf Cart Part No 50.056.06.000. , Headless Pipe Plug1-11.5 Nptf Cart Part No 50.056.08.000. , Allen Headed Bolt M4 X 35L Cart Part No 50.076.04.035. , Socket Head Cap Screw M5x020 12 9 Cart Part No 50.076.05.020. , Allen Screw Cart Part No 50.076.05.035. , Socket Head Cap Screw - M6x012 - 12.9 Cart Part No 50.076.06.012. , Socket Head Cap Screw M6x040 12 9 Cart Part No 50.076.06.040. , Allen Bolt M6 X 050 Cart Part No 50.076.06.050. , Chc Screw Cart Part No 50.076.08.030. , Allen Screw Cart Part No 50.076.08.040. , Socket Head Cap Screw M8x70 -12.9 Cart Part No 50.076.08.070. , Socket Head Cap Screw M8x90 -12.9 Cart Part No 50.076.08.090. , Allen Screw Cart Part No 50.076.10.020. , Socket Head Cap Screw-M10x25-12.9 Cart Part No 50.076.10.025. , Socket Head Cap Screw-M10x30-12.9 Cart Part No 50.076.10.030. , Socket Head Cap Screw M10x045 12 9 Cart Part No 50.076.10.045. , Socket Head Screw - M10x1.5X55 - 12.9 Cart Part No 50.076.10.055. , Socket Head Cap Screw-M10x60-12.9 Cart Part No 50.076.10.060. , Allen Screw M 10 X 70 Mm Cart Part No 50.076.10.070. , Socket Head Cap Screw M10x75 12 9 Cart Part No 50.076.10.075. , Socket Head Cap Screw-M16x35-12.9 Cart Part No 50.076.16.035. , Socket Head Screw (Din912 M16x50 -12.5) Cart Part No 50.076.16.050. , Socket Head Screwdin912 M16x7012 5 Cart Part No 50.076.16.070. , Allen Screw Cart Part No 50.076.16.090. , Nut (Ss) - M8x1.25 Cart Part No 50.080.08.000. , S.S. Nut M10-Aisi-304 Cart Part No 50.080.10.000. , Banjo One Sided Sf M18 Bolt - For 1/2 Rubber Hose. Cart Part No 50.085.12.000. , Oil Seal 32X45x6w21502 Cart Part No 50.302.36.000. , Dowel Pins Cart Part No 50.401.04.012. , Dowel Pin - Bar Cart Part No 50.401.05.010. , Dowel (5 X 10) Cart Part No 50.401.06.010. , Dowel Cart Part No 50.401.06.012. , Dowel Pin Cart Part No 50.401.06.014. , Dowel Pin Cart Part No 50.401.06.025. , Dowel Pin Cart Part No 50.401.07.012. , Dowel Pin 6X30 Cart Part No 50.401.07.030. , Dowel Cart Part No 50.401.08.012. , Dowel Cart Part No 50.401.08.014. , Dowel Pin Cart Part No 50.401.08.016. , Dowel Pin 8X25 Cart Part No 50.401.08.025. , Dowel Pin 8X45 Cart Part No 50.401.08.045. , Dowel Pin 8X60 Cart Part No 50.401.08.060. , Dowel Pin 8X65 Cart Part No 50.401.08.065. , Dowel Pin 10X20 Cart Part No 50.401.09.020. , Dowel Pin Cart Part No 50.401.10.030. , Key(Impeller) Cart Part No 50.402.06.014. , Woodruff Key (4 X 6.5) Cart Part No 50.405.10.000. , Woodruff Key Cart Part No 50.405.12.000. , Circlip External 15 Mm Cart Part No 50.501.15.000. , Circlip External : 16 Mm Cart Part No 50.501.16.000. , Circlip External - 20 Mm Cart Part No 50.501.20.000. , Circlip External - 25 Mm Cart Part No 50.501.25.000. , Circlip External - 30 Mm Cart Part No 50.501.30.000. , Circlip External - 35 Mm Cart Part No 50.501.35.000. , Circlip External - 40 Mm Cart Part No 50.501.40.000. , External Circlip (55 Dia Shaft) Cart Part No 50.501.55.000. , Circlip Internal : 32 Mm Cart Part No 50.502.32.000. , Circlip (Internal)-35 Mm Cart Part No 50.502.35.000. , Circlip Internal - 40 Mm Cart Part No 50.502.40.000. , Circlip: Internal 42Mm Cart Part No 50.502.42.000. , Circlip Internal : 45 Mm Cart Part No 50.502.45.000. , Circlip Internal - 47 Mm Cart Part No 50.502.47.000. , Circlip Internal - 52 Mm Cart Part No 50.502.52.000. , Circlip Internal-55Mm Cart Part No 50.502.55.000. , Circlip Internal - 62 Mm Cart Part No 50.502.62.000. , Circlip Internal 68 Mm Cart Part No 50.502.68.000. , Circlip Internal - 72 Mm Cart Part No 50.502.72.000. , Circlip Internal - 80 Mm Cart Part No 50.502.80.000. , Circlip Internal - 90 Mm Cart Part No 50.502.90.000. , Banjo Cart Part No 50.503.04.000. , Banjo Bolt: M8x1.25 Cart Part No 50.504.01.000. , Banjo Bolt: M10x1.5 Cart Part No 50.504.02.000. , Banjo Bolt: M12x1.5 Cart Part No 50.504.03.000. , Banjo Bolt :M14x1.5 Cart Part No 50.504.04.000. , Banjo Bolt - M16x1.5 Cart Part No 50.504.05.000. , Banjo Bolt: M18x1.5 Cart Part No 50.504.06.000. , Banjo Bolt M22x1 5 Cart Part No 50.504.07.000. , Banjo Bolt M30x1 5 Cart Part No 50.504.09.000. , Spring Washer - M5 Cart Part No 50.505.05.000. , Spring Washer -M6 Cart Part No 50.505.06.000. , Spring Washer - M8 Cart Part No 50.505.08.000. , Spring Washer - M10 Cart Part No 50.505.10.000. , Spring Washer - M12 Cart Part No 50.505.12.000. , Spring Washer - M14 Cart Part No 50.505.14.000. , Spring Washer - M16 Cart Part No 50.505.16.000. , Spring Washer - M18 Cart Part No 50.505.18.000. , Spring Washer - M20 Cart Part No 50.505.20.000. , Spring Washer - M24 Cart Part No 50.505.24.000. , Plain Machined Washer - M4 Cart Part No 50.506.04.000. , Plain Machined Washer - M5 Cart Part No 50.506.05.000. , Plain Machined Washer - M6 Cart Part No 50.506.06.000. , Plain Machine Washer - M8 Cart Part No 50.506.08.000. , Plain Machined Washer - M10 Cart Part No 50.506.10.000. , Plain Machine Washer - M12 Cart Part No 50.506.12.000. , Plain Machined Washer - M14 Cart Part No 50.506.14.000. , Plain Machined Washer - M16 Cart Part No 50.506.16.000. , Plain Machined Washer M18 Cart Part No 50.506.18.000. , Plain Machined Washer - M20 Cart Part No 50.506.20.000. , Plain Machined Washer - M22 Cart Part No 50.506.22.000. , Plain Machined Washer - M24 Cart Part No 50.506.24.000. , Plain Punched Washer - M6 Cart Part No 50.507.06.000. , Plain Punched Washer - M8 Cart Part No 50.507.08.000. , Plain Punched Washer - M10 Cart Part No 50.507.10.000. , Plain Punched Washer M12 Cart Part No 50.507.12.000. , Copper Washer (6X9) Cart Part No 50.508.03.000. , Copper Washer (6X10) Cart Part No 50.508.04.000. , Copper Washer (8X12) Cart Part No 50.508.05.000. , Copper Washer (8X14) Cart Part No 50.508.06.000. , Copper Washer (10X14) Cart Part No 50.508.07.000. , Copper Washer (10X16) Cart Part No 50.508.08.000. , Copper Washer (12X16) Cart Part No 50.508.09.000. , Copper Washer (12X18) Cart Part No 50.508.10.000. , Copper Washer (14X18) Cart Part No 50.508.11.000. , Copper Washer (14X20) Cart Part No 50.508.12.000. , Copper Washer (16X20) Cart Part No 50.508.13.000. , Copper Washer (16X22) Cart Part No 50.508.14.000. , Copper Washer (17X23) Cart Part No 50.508.15.000. , Copper Washer (18X22) Cart Part No 50.508.16.000. , Copper Washer (18X24) Cart Part No 50.508.17.000. , Copper Washer (20X24) Cart Part No 50.508.18.000. , Copper Washer (20X26) Cart Part No 50.508.19.000. , Copper Washer (20X27) Cart Part No 50.508.20.000. , Copper Washer (21X27) Cart Part No 50.508.21.000. , Copper Washer (21X31) Cart Part No 50.508.22.000. , Copper Washer (22X27) Cart Part No 50.508.23.000. , Copper Washer (22X29) Cart Part No 50.508.24.000. , Copper Washer( 22.2X28.5) Cart Part No 50.508.25.000. , Copper Washer (24X29) Cart Part No 50.508.27.000. , Copper Washer (26X32) Cart Part No 50.508.29.000. , Copper Washer (27X34) Cart Part No 50.508.31.000. , Copper Washer (28X33) Cart Part No 50.508.32.000. , Copper Washer (30X34) Cart Part No 50.508.33.000. , Copper Washer (30X36) Cart Part No 50.508.34.000. , Copper Washer (30X38) Cart Part No 50.508.35.000. , Copper Washer (48X52) Cart Part No 50.508.45.000. , Hose Clip Cart Part No 50.519.02.000. , Hose Clip 48Mm Cart Part No 50.519.09.000. , Banjo Bolt 1 4Bsp Cart Part No 50.538.03.000. , Spring Dowel Pin Cart Part No 50.540.09.016. , Spring Dowel (6 X 45) Cart Part No 50.540.10.045. , Spring Dowel Cart Part No 50.540.11.018. , Pipe Clipfor 2 Pipes Cart Part No 50.541.01.000. , Notched Pin Cart Part No 50.543.09.010. , Washer M5 Cart Part No 50.548.05.000. , Washer Cart Part No 50.548.06.000. , Spl Plain Machined Washer Cart Part No 50.548.08.000. , Special Plainwasher - M10 Cart Part No 50.548.10.000. , Spl Plain Washer - M12 Cart Part No 50.548.12.000. , Spl Plain Washer - M14 Cart Part No 50.548.14.000. , Washer Cart Part No 50.548.18.000. , Special Washer. Cart Part No 50.548.20.000. , Core Plug 1/4Bsp Cart Part No 50.601.02.000. , Drain Plug 3/8 Bsp Cart Part No 50.601.03.000. , Plug: M14x1.5 Cart Part No 50.602.14.000. , Core Plug Cart Part No 50.602.18.000. , Core Plug (Dish Type) Cart Part No 50.609.13.000. , Core Plug Cart Part No 50.610.10.000. , Core Plug Cart Part No 50.610.12.000. , Core Plug-Hexagonal Socket Head(Din-908) Cart Part No 50.610.14.000. , Core Plug Hexagonal Socket Head Din 908 Cart Part No 50.610.16.000. , Core Plug Hexagonal Socket Head(Din 908) Cart Part No 50.610.20.000. , Core Plug Hexagonal Socket Head(M22x1.5) Cart Part No 50.610.22.000. , Core Plug Cart Part No 50.610.24.000. , Core Plug(M27x2)-Hexagonal Socket Head(Din 908) Cart Part No 50.610.27.000. , Core Plug Hexagonal Socket Head Din 908 Cart Part No 50.610.30.000. , Core Plug Cart Part No 50.611.06.000. , Core Plug Hexagonal Headdin 7604 Cart Part No 50.611.07.000. , Worm Drive Hose Clip18 Mm Cart Part No 50.907.02.000. , Worm Drive Hose Clip (22 Mm) Cart Part No 50.907.03.000. , Worm Drive Hose Clip (25 Mm) Cart Part No 50.907.04.000. , Worm Drive Hose Clip (28 Mm) Cart Part No 50.907.05.000. , Hose Clip: Worm Drive 32Mm Cart Part No 50.907.06.000. , Worm Drive Hose Clip (41 Mm) Cart Part No 50.907.07.000. , Worm Drive Hose Clip (45 Mm) Cart Part No 50.907.08.000. , Worm Drive Hose Clip (55 Mm) Cart Part No 50.907.09.000. , Worm Drive Hose Clip (70 Mm) Cart Part No 50.907.10.000. , Worm Drive Hose Clip80 Mm Cart Part No 50.907.11.000. , Worm Drive Hose Clip90 Mm Cart Part No 50.907.12.000. , Worm Drive Hose Clip (102 Mm) Cart Part No 50.907.13.000. , Worm Drive Hose Clip (115 Mm) Cart Part No 50.907.14.000. , Worm Drive Hose Clip (127 Mm) Cart Part No 50.907.15.000. , Flanged Nut Grade 8 Cart Part No 50.908.05.000. , Flanged Nut Grade 8 Cart Part No 50.908.06.000. , Flangedm8 Nut Grade 8 Cart Part No 50.908.08.000. , Flanged Nut (Hexagon) Cart Part No 50.908.10.000. , Flanged Nut Grade 8 Cart Part No 50.908.12.000. , Falnged Bolt Grade 8.8 Cart Part No 50.911.05.014. , Flanged Bolt Grade 8.8M6 X 1 X 10 Cart Part No 50.911.06.010. , Flanged Bolt Grade 8.8M6 X 1 X 012 Cart Part No 50.911.06.012. , Flanged Bolt Grade 8.8M6 X 1.25 X 15 Cart Part No 50.911.06.015. , Flanged Bolt Grade 8.8M6 X 1.25 X 16 Cart Part No 50.911.06.016. , Flanged Bolt Grade 8.8M6 X 1 X 20 Cart Part No 50.911.06.020. , Flanged Bolt Grade 8.8M6 X 1 X 25 Cart Part No 50.911.06.025. , Flanged Bolt Grade 8.8M6 X 1 X 035 Cart Part No 50.911.06.035. , Flanged Bolt Grade 8.8M6 X 1 X 40 Cart Part No 50.911.06.040. , Flanged Bolt Grade 8.8M6 X 1 X 045 Cart Part No 50.911.06.045. , Flanged Bolt Grade 8.8M6 X 1 X 050 Cart Part No 50.911.06.050. , Flanged Bolt 8.8 Grade Cart Part No 50.911.06.055. , Flanged Bolt Grade 8.8M6 X 1 X 060 Cart Part No 50.911.06.060. , Flanged Bolt Grade 8.8M8 X 1.25 X 012 Cart Part No 50.911.08.012. , Flanged Bolt Grade 8.8M8 X 1.25 X 15 Cart Part No 50.911.08.015. , Flanged Bolt Grade 8.8M8 X 1.25 X 16 Cart Part No 50.911.08.016. , Flanged Bolt Grade 8.8M8 X 1.25 X 018 Cart Part No 50.911.08.018. , Flanged Bolt Grade 8.8M8 X 1.25 X 20 Cart Part No 50.911.08.020. , Flanged Bolt Grade 8.8M8 X 1.25 X 022 Cart Part No 50.911.08.022. , Flanged Bolt Grade 8.8M8 X 1.25 X 25 Cart Part No 50.911.08.025. , Flanged Bolt Grade 8.8M8 X 1.25 X 28 Cart Part No 50.911.08.028. , Flanged Bolt Grade 8.8 Cart Part No 50.911.08.030. , Flanged Bolt Grade 8.8M8 X 1.25 X 35 Cart Part No 50.911.08.035. , Flanged Bolt Grade 8.8M8 X 1.25 X 40 Cart Part No 50.911.08.040. , Flanged Bolt Grade 8.8M8 X 1.25 X 45 Cart Part No 50.911.08.045. , Flanged Bolt Grade 8.8M8 X 1.25 X 050 Cart Part No 50.911.08.050. , Flanged Bolt Grade 8.8M8 X 1.25 X 055 Cart Part No 50.911.08.055. , Flanged Bolt Grade 8 8 Cart Part No 50.911.08.060. , Flanged Bolt Grade 8.8M8 X 1.25 X 65 Cart Part No 50.911.08.065. , Flanged Bolt Grade 8.8M8 X 1.25 X 070 Cart Part No 50.911.08.070. , Flanged Bolt Grade 8.8M8 X 1.25 X 80 Cart Part No 50.911.08.080. , Flanged Bolt Grade 8.8M8 X 1.25 X 085 Cart Part No 50.911.08.085. , Flanged Bolt Grade 8.8M8 X 1.25 X 090 Cart Part No 50.911.08.090. , Flanged Bolt Grade 8.8M8 X 1.25 X 110 Cart Part No 50.911.08.110. , Flanged Bolt Grade 8.8M8 X 1.25 X 115 Cart Part No 50.911.08.115. , Flanged Bolt Grade 8.8M8 X 1.25 X 120 Cart Part No 50.911.08.120. , Flanged Bolt Grade 8.8M8 X 1.25 X 130 Cart Part No 50.911.08.130. , Flanged Bolt Grade 8 8M8 X 1 25 X 140 Cart Part No 50.911.08.140. , Flanged Bolt Grade 8.8 Cart Part No 50.911.10.015. , Flanged Bolt Grade 8.8M10 X 1.5 X 20 Cart Part No 50.911.10.020. , Flanged Bolt Grade 8.8M10 X 1.5 X 022 Cart Part No 50.911.10.022. , Flanged Bolt Grade 8.8M10 X 1.5 X 25 Cart Part No 50.911.10.025. , Flanged Bolt Grade 8.8M10 X 1.5 X 30 Cart Part No 50.911.10.030. , Flanged Bolt Grade 8.8M10 X 1.5 X 35 Cart Part No 50.911.10.035. , Flanged Bolt Grade 8.8M10 X 1.5 X 40 Cart Part No 50.911.10.040. , Flanged Bolt Grade 8 8M10 X 1 5 X 50 Cart Part No 50.911.10.050. , Flanged Bolt Grade 8.8M10 X 1.5 X 55 Cart Part No 50.911.10.055. , Flanged Bolt Grade 8.8M10 X 1.5 X 65 Cart Part No 50.911.10.065. , Flanged Bolt Grade 8.8M10 X 1.5 X 70 Cart Part No 50.911.10.070. , Flanged Bolt Grade 8.8 Cart Part No 50.911.10.075. , Flanged Bolt Grade 8.8M10 X 1.5 X 80 Cart Part No 50.911.10.080. , Flanged Bolt Grade 8 8M10 X 1 5 X 85 Cart Part No 50.911.10.085. , Flanged Bolt Grade 8 8M10 X 1 5 X 90 Cart Part No 50.911.10.090. , Flanged Bolt Grade 8 8 M10 X 1 5 X 105 Cart Part No 50.911.10.105. , Flanged Bolt Grade 8.8M12 X 1.75 X 25 Cart Part No 50.911.12.025. , Flanged Bolt Grade 8.8M12 X 1.75 X 30 Cart Part No 50.911.12.030. , Flanged Bolt Grade 8.8M12 X 1.75 X 35 Cart Part No 50.911.12.035. , Flanged Bolt Grade 8.8M12 X 1.75 X 90 Cart Part No 50.911.12.090. , Flanged Bolt Grade 8.8M12 X 1.75 X 190 Cart Part No 50.911.12.190. , Flanged Bolt (Grade 10.9) M8 X 1.25 X 020 Cart Part No 50.912.08.020. , Hexagonal Flanged Bolts(Grade 10.9) Cart Part No 50.912.08.025. , Flanged Bolt Grade 8.8, M8x1.5X030 Cart Part No 50.912.08.030. , Flanged Bolt Cart Part No 50.912.08.035. , Hexagonal Bolts With Flange (Grade 10.9) Cart Part No 50.912.10.025. , Flanged Bolt 10.9 Grade Cart Part No 50.912.12.050. , Flanged Nut Grade 10.9 Cart Part No 50.915.06.000. , Flanged Nut 10.9 Grade Cart Part No 50.915.08.000. , Cambush Cart Part No 5H.001.08.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.110.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.70.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.90.0.Pr , Crankshaft (Machining) With Integral Balance Weight Cart Part No 5H.005.03.0.00 , Crankshaft Asslywith Gear Cart Part No 5H.005.90.0.Pr , Cyl Head Assemblycomplete Cart Part No 5H.007.30.0.Pr , Cyl Head With Valve Guide Valve Seat Insert Cart Part No 5H.007.50.0.Pr , O Ring: Cylinder Liner Cart Part No 5H.008.02.0.00 , Cyl Liner Assembly Cart Part No 5H.008.10.0.00 , Piston Assembly Cart Part No 5H.009.10.0.00 , Piston Assly. Complete Cart Part No 5H.009.130.0.Pr , Piston Asslycomplete Cart Part No 5H.009.50.0.Pr , Piston Ring Set3 Ring Version Cart Part No 5H.009.60.0.Pr , Piston Asslycomplete Cart Part No 5H.009.90.0.Pr , Injector Clamp Cart Part No 5H.010.02.0.Pr , Dowel Pin (For Injector Clamp) Cart Part No 5H.010.03.0.Pr , Inlet Manifold Cart Part No 5H.013.01.0.00 , Inlet Manifold Cart Part No 5H.013.01.0.Pr , Inlet Manifold Cart Part No 5H.013.02.0.Pr , Exhaust Manifold4 Valve Cart Part No 5H.014.01.0.Pr , Exhaust Manifold Cart Part No 5H.014.02.0.00 , Exhaust Manifold Cart Part No 5H.014.03.0.Pr , Gasket (For Turbocharger) Cart Part No 5H.014.04.0.Pr , Expansion Bellow Cart Part No 5H.014.08.0.Pr , Exhaust Manifold With Hr Paint Cart Part No 5H.014.11.0.00 , Gear Casing Cart Part No 5H.015.02.0.00 , Joint Cart Part No 5H.015.14.0.Pr , Support For Idler Pulley Cart Part No 5H.015.23.0.Pr , Idler Pulley Cart Part No 5H.015.31.0.Pr , Cb18 Fuel Pump Cart Part No 5H.016.01.0.Pr , Oil Supply Pipefor Fuel Pump Cart Part No 5H.016.02.0.Pr , Hub(For Fuel Pump Gear) Cart Part No 5H.018.01.0.Pr , Spin On Cartridge For 5H019 02 0 Pr Bs Iv Pre Filter Cart Part No 5H.019.001.0.00 , Spin On Cartridge For 5H019 01 0 Pr Bs Iv Main Fuel Filter Cart Part No 5H.019.002.0.00 , Fuel Filter With Hand Primer Cart Part No 5H.019.01.0.00 , Pre Filter Cart Part No 5H.019.02.0.00 , Water In Fuel Switch (Common Rail) Cart Part No 5H.019.03.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.019.13.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.019.14.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 5H.019.16.0.Sp , Adaptorrocker Cover Breather Hose Cart Part No 5H.020.02.0.Pr , Gasketbreather Adaptor Rocker Cover Cart Part No 5H.020.04.0.00 , Breather Pipe Cart Part No 5H.020.08.0.Pr , Breather Pipe Cart Part No 5H.020.13.0.Pr , Breather Pipe Cart Part No 5H.020.14.0.Pr , Hose Cart Part No 5H.020.15.0.Pr , Breather Pipe Cart Part No 5H.020.17.0.Pr , Hose (540L) Cart Part No 5H.020.18.0.Pr , Hose580l Cart Part No 5H.020.19.0.Pr , Hose660l Cart Part No 5H.020.21.0.00 , Cover For Cam Bore Cart Part No 5H.022.02.0.Pr , Cover Plate For Fuel Pump Cart Part No 5H.023.02.0.Pr , Camshaft Assembly Cart Part No 5H.024.20.0.Pr , Camshaft Assly Cart Part No 5H.024.50.0.Pr , Gasketbellow Exhaust Manifold Cart Part No 5H.025.02.0.00 , Expansion Bellowfor Exhaust Cart Part No 5H.025.04.0.Pr , O Ring (Egr Water In & Out) Cart Part No 5H.025.08.0.Pr , Gasketexhaust Pipe Egr Cooler Cart Part No 5H.025.11.0.Pr , Oringegr Cooler Water In Cart Part No 5H.025.13.0.Pr , Oringegr Cooler Water Out Cart Part No 5H.025.14.0.Pr , Expansion Bellow Cart Part No 5H.025.16.0.Pr , Egr Pipeegr Valve Side Cart Part No 5H.025.17.0.00 , Egr Pipeegr Valve Side Cart Part No 5H.025.17.0.Pr , Exhaust Pipebellow To Egr Cart Part No 5H.025.21.0.Pr , Egr Pipeegr Cooler Side Cart Part No 5H.025.22.0.00 , Adaptoregr Cooler Water In Cart Part No 5H.025.23.0.00 , Adaptoregr Cooler Water In Cart Part No 5H.025.23.0.Pr , Adaptoregr Cooler Water Out Cart Part No 5H.025.24.0.00 , Adaptoregr Cooler Water Out Cart Part No 5H.025.24.0.Pr , Egr Cooler 5 Kw Cart Part No 5H.025.25.0.00 , Gasketbetween Egr Cooler And Exhaust Pipe Cart Part No 5H.025.26.0.00 , Adaptor Cart Part No 5H.025.27.0.00 , Fuel Pipe (Fuel Pump To Fuel Filter) Cart Part No 5H.026.02.0.00 , Plate (For Fuel Pipe Clamp) Cart Part No 5H.026.04.0.Pr , Bracketfor Fuel Filter Cart Part No 5H.026.06.0.Pr , Egr Valve Assembly For 4R1190 Bs-Iv Cart Part No 5H.027.01.0.Pr , Adaptor Cart Part No 5H.027.03.0.Pr , Gasketegr Mixer Inlet Manifold Cart Part No 5H.027.05.0.Pr , Hoseegr Valve Water Inlet Cart Part No 5H.027.06.0.Pr , Hoseegr Valve Water Out Cart Part No 5H.027.07.0.Pr , Gasket Between Egr Valve And Egr Pipe Cart Part No 5H.027.08.0.00 , Gasket Between Egr Mixer And Egr Valve Cart Part No 5H.027.09.0.00 , Platefor Hose Clamp Cart Part No 5H.027.11.0.Pr , Clamp Cart Part No 5H.027.12.0.Pr , Clamp Cart Part No 5H.027.14.0.Pr , Spring Band Clamp Id 13.3-14 Cart Part No 5H.027.15.0.Pr , Adaptor Cart Part No 5H.027.16.0.Pr , Hose Cart Part No 5H.027.21.0.Pr , Hose (Crankcase To Egr Valve) Cart Part No 5H.027.22.0.Pr , Gasketthrottle Valve Mixer Cart Part No 5H.029.02.0.Pr , Gasketthrottle Valve Heater Cart Part No 5H.029.03.0.Pr , Spacerfor Intake Throttle Valve Cart Part No 5H.029.05.0.Pr , Intake Throttle Valve (Yazaki Connector) Cart Part No 5H.029.07.0.Pr , Vband Clamp Cart Part No 5H.030.01.0.Pr , Bracket For Ecu Mounting Cart Part No 5H.031.02.0.Pr , Gasketrocker Cover Cart Part No 5H.032.02.0.00 , Wire Mesh66 5X10x18 236 Gaugesteel Wire Cart Part No 5H.032.03.0.Pr , Baffle Plate Cart Part No 5H.032.04.0.Pr , Bolt For Rocker Cover Cart Part No 5H.032.05.0.Pr , Rocker Cover Cart Part No 5H.032.06.0.Pr , Baffle Plate Cart Part No 5H.032.09.0.Pr , Rocker Cover Assembly Cart Part No 5H.032.70.0.Pr , Valve Bridge (For Rocker Lever) Cart Part No 5H.034.09.0.Pr , Valve Rocker Leverassy Complete Cart Part No 5H.034.50.0.Pr , Shaft Sub Assembly (4 Valve) Cart Part No 5H.034.60.0.00 , Intake Rocker Arm – Hla Assembly Cart Part No 5H.034.70.0.Pr , Exhaust Rocker Arm – Hla Assembly Cart Part No 5H.034.80.0.Pr , Valve Rocker Lever (Assy Complete) Cart Part No 5H.034.90.0.Pr , Leakoff Pipe Cart Part No 5H.035.01.0.Pr , Platefor Leak Off Clamp Cart Part No 5H.035.08.0.Pr , Clamp Cart Part No 5H.035.11.0.Pr , Clamp (For Tube Od 6-6.5) Cart Part No 5H.035.17.0.Pr , Metallic Leak Off Pipe (Injector Side) Cart Part No 5H.035.18.0.Pr , Worm Drive Hose Clamp (Dia 6) Cart Part No 5H.035.19.0.Pr , Bracketdoc Mounting Cart Part No 5H.036.02.0.Pr , Bracket For Doc Mounting Cart Part No 5H.036.08.0.Pr , Bracket For Scr Mounting Cart Part No 5H.036.09.0.Pr , Urea Tank Assembly 4R1190ta Bsiv Cart Part No 5H.036.10.0.Pr , Adblue Tank Bracket Assly Cart Part No 5H.036.100.0.Pr , Urea Return Pipe Supply Module To Tank Cart Part No 5H.036.101.0.Pr , Urea Pipe (Tank To Supply Module) Cart Part No 5H.036.102.0.Pr , Clamp Two Pipe Clip Id 8 9 Cart Part No 5H.036.103.0.Pr , Coated Ceramic Substrate (5.2D X 5.25L) With 5G/Ft3 Pt Loading Cart Part No 5H.036.125.0.Pr , Water In Pipe Pipe (Crancase To Dosing Module) Cart Part No 5H.036.137.0.Pr , Water In Pipe Cart Part No 5H.036.143.0.Pr , Water Out Pipe (Dosing Module To Thermostat For Top Mounted)) Cart Part No 5H.036.148.0.Pr , Mounting Bracket For Doc Scr Cart Part No 5H.036.17.0.Pr , 4R1190ta Bsiv Urea Tank Assemblywith Modified Filter And Rua Table Urea Tank A Cart Part No 5H.036.18.0.Pr , Bracket For Scu Mounting Cart Part No 5H.036.19.0.Pr , Docupward Opening (Diesel Oxidation Catalyst) Cart Part No 5H.036.20.0.Pr , Doc Mounting Bracket Cart Part No 5H.036.24.0.Pr , Doc Mountingbracket Support 2 Cart Part No 5H.036.25.0.Pr , Doc Mountingbracket Support 1 Cart Part No 5H.036.26.0.Pr , Docdownward Opening 20 Cart Part No 5H.036.30.0.Pr , Urea Tank Air Vent Cart Part No 5H.036.31.0.Pr , Urea Tank O-Ring Cart Part No 5H.036.32.0.Pr , Urea Tank Filling Neck Cart Part No 5H.036.33.0.Pr , Urea Tank Locking Cap Cart Part No 5H.036.34.0.Pr , Urea Tank Adblue Sensor Cart Part No 5H.036.35.0.Pr , Urea Tank Filler Filter Cart Part No 5H.036.36.0.Pr , Urea Tank Drain Plug Cart Part No 5H.036.37.0.Pr , Jsr01144,O Ring For Sensor Cart Part No 5H.036.41.0.Pr , Adblue Level ,Quality Temp Sensor For 25 Ltr Tank Cart Part No 5H.036.43.0.Pr , 5H 036 70 0 00Doc 4 75 Ltr Na Type 4 Platform 1 Gm Cft 1 0 05 2X 5 2X 5 25L400 4 Cart Part No 5H.036.70.0.00 , Rubber Mount 25X20 Cart Part No 5H.036.88.0.Pr , Plate Cart Part No 5H.036.89.0.Pr , Rubber Strip Cart Part No 5H.036.96.0.Pr , Doc (Upward Opening) Cart Part No 5H.037.20.0.Sp , O Ring Air Sensor Adaptor Cart Part No 5H.039.02.0.Pr , Spacer Plate Cart Part No 5H.039.03.0.Pr , Pipe (Air Inlet) Cart Part No 5H.039.04.0.Pr , Adaptorfor Air Sensor Cart Part No 5H.039.05.0.Pr , V Band Clamp Cart Part No 5H.039.06.0.Pr , H Ppipefor Cyl1 Cart Part No 5H.040.10.0.00 , Hppipefor Cyl2 Cart Part No 5H.040.20.0.00 , Hppipefor Cyl3 Cart Part No 5H.040.30.0.00 , Hppipefor Cyl4 Cart Part No 5H.040.40.0.00 , Hppipepump To Rail Cart Part No 5H.040.50.0.00 , Hppipepump To Rail Cart Part No 5H.040.60.0.00 , Engine Wiring Harness For 4R1190na Bsiv Engine Cart Part No 5H.043.22.0.Pr , Engine Wiring Harness For 4R1190ta Bsiv Engine Cart Part No 5H.043.32.0.Pr , Header For Lub Oil Cooler And Spin On Filter Cart Part No 5H.045.01.0.00 , Headerfor Remote Lub Oil Filter Cart Part No 5H.045.02.0.Pr , Extension Wiring Harness For 4R1190ta Bs-Iv Engine 110Hp (For Top Mtg Egt) Cart Part No 5H.045.32.0.Pr , Extension Wiring Harness For 4R1190ta Bs Iv Engine 110Hpfor Flywheel Mtg Egt Cart Part No 5H.045.50.0.Pr , Lub Oil Cooler Header Assembly Cart Part No 5H.045.90.0.Pr , Heater Wire Support Bracket S F 4R1190 Bsiv Engine Cart Part No 5H.046.122.0.Pr , Air Cleaner Assembly (350 Kg/Hr) 90 Deg Bend Outlet Spout (Fp-G080726) Cart Part No 5H.050.10.0.Pr , Platefor Roller Tappet Cart Part No 5H.051.05.0.Pr , Platefor Roller Tappet Cart Part No 5H.051.07.0.Pr , Roller Tappet Assembly Cart Part No 5H.051.10.0.Pr , Push Rod (Welded) Cart Part No 5H.051.30.0.Pr , Adaptor (For Turbo Oil Inlet 11/16-16 Unf To 12) Cart Part No 5H.053.01.0.Pr , Adaptor Crankcase Sideunf 11 16 16 Cart Part No 5H.053.02.0.Pr , Lub Oil Supply Pipefor Turbocharger Cart Part No 5H.053.10.0.Pr , Drain Pipewith Flange And Sleeve Cart Part No 5H.053.20.0.Pr , Turbo Drain Pipe Cart Part No 5H.053.22.0.Pr , Lub Oil Supply Pipefor Turbocharger Cart Part No 5H.053.30.0.Pr , Drain Pipewith Flange And Sleeve Cart Part No 5H.053.40.0.Pr , Turbo Oil In Pipe Cart Part No 5H.053.50.0.Pr , Turbo Oil Drain Pipe Cart Part No 5H.053.60.0.Pr , Turbo Drain Pipe Cart Part No 5H.053.70.0.Pr , Drain Pipewith Flange Sleeve Cart Part No 5H.053.71.0.Pr , Turbo Drain Pipewith Flange Sleeve Cart Part No 5H.053.80.0.Pr , Crankshaft Pulley With Poly V Groove For 143 Pcd Cart Part No 5H.054.01.0.Pr , Pulley100 Pcdpolyv For Water Pump Cart Part No 5H.055.01.0.Pr , 115529021814 Turbocharger Cart Part No 5H.056.01.0.Pr , Turbocharger Cart Part No 5H.056.02.0.Pr , Turbocharger Cart Part No 5H.056.05.0.Pr , Turbocharger For 4R Cpcb4engine B1 055C81qs24a01enc110 24 058X71af18r70es Cart Part No 5H.056.07.0.Pr , Turbocharger For 4K1080ta Cpcb 4+ Engine Cart Part No 5H.056.10.0.Pr , Turbocharger For 4R1190t-Ht Top Mounted Orientation Cart Part No 5H.056.12.0.Pr , Turbocharger Top Mounted Cart Part No 5H.056.18.0.Pr , Flywheel Housing Sae3w155ss Bb Cart Part No 5H.057.01.0.Pr , Flywheel Assembly Cart Part No 5H.058.20.0.Pr , Thermostat Housing Assembly Opening Toward Exhaust And Tall Height Cart Part No 5H.059.10.0.Pr , Exhaust Diffuser Cart Part No 5H.060.01.0.Pr , Expansion Bellow Cart Part No 5H.060.03.0.Pr , Exhaust Pipe Cart Part No 5H.060.04.0.Pr , Gasket (Exahust Pipe And Doc ) Cart Part No 5H.060.05.0.00 , Exhaust Pipe Cart Part No 5H.060.07.0.Pr , Exhaust Pipebetween Diffuser And Expansion Bellow Cart Part No 5H.060.08.0.Pr , Exhaust Pipe With Bellow (Doc Side ) Cart Part No 5H.060.17.0.Pr , V Clamp For Dm 3.2 Cart Part No 5H.061.02.0.Pr , Lub Oil Sumpdrain Plug At Bottom Side Cart Part No 5H.062.01.0.Pr , Closed Crankcase Ventilationccv 4R1190ta Cart Part No 5H.063.01.0.Pr , Bracket For Ccv Mtg 4R1190ta Cart Part No 5H.063.02.0.Pr , Hoseblow By In Cart Part No 5H.063.03.0.Pr , Oil Drain Hose4r1190ta Cart Part No 5H.063.04.0.Pr , Blow By Out Hose (Ccv Side) Cart Part No 5H.063.05.0.Pr , Intermediate Pipeccv Out Cart Part No 5H.063.06.0.Pr , Clamp Dia9 11 Cart Part No 5H.063.08.0.Pr , Clamp Cart Part No 5H.063.12.0.Pr , Hose Pipe Oil Drain To Sump Cart Part No 5H.063.18.0.Pr , Mtg. Bracket For Ccv (4R1190na) Cart Part No 5H.063.19.0.Pr , Oil Drain Hose Pipeccv To Sump Cart Part No 5H.063.21.0.Pr , Oil Drain Hose Pipeccv To Ci Sump Cart Part No 5H.063.25.0.Pr , Bracketfor Ccv Mounting Cart Part No 5H.063.31.0.Pr , Hose Piperocker Cover To Ccv Cart Part No 5H.063.32.0.Pr , Hose Pipeccv To Air Inlet Pipe Cart Part No 5H.063.33.0.Pr , Oil Drain Hoseccv To Ci Sump Cart Part No 5H.063.34.0.Pr , Pipe (Oil Drain To Sump) Cart Part No 5H.063.52.0.Pr , Hose12 Id 60 L Cart Part No 5H.063.66.0.Pr , Lube Oil Sump Fabricated Cart Part No 5H.064.01.0.Pr , Lub Oil Sumpfabricated Cart Part No 5H.064.03.0.Pr , Gasket Cart Part No 5H.070.01.0.Pr , V-Band Clamp Cart Part No 5H.070.02.0.Pr , Assembly Of Emission After Treatment For 110 Hp Bs Ivdoc Dcom Tube Scrvari Cart Part No 5H.070.10.0.Pr , Docside Mounted Cart Part No 5H.070.100.0.Pr , Scrside Mounted Cart Part No 5H.070.110.0.Pr , 4R1190ta Bsiv Egt Strap Assembly Spare Part Cart Part No 5H.070.120.0.Sp , Strap For Egt Assembly Cart Part No 5H.070.121.0.Pr , 4R1190na Bsiv Egt Strap Assembly Spare Part Cart Part No 5H.070.130.0.Sp , Assembly Of Emission After Treatment For 110 Hp Bs Ivdoc Dcom Tube Scrvari Cart Part No 5H.070.20.0.Pr , Doctop Mounted Cart Part No 5H.070.200.0.Pr , Scrtop Mounteddownward Opening Cart Part No 5H.070.210.0.Pr , Poly V Belt 6Pk 1215 Epdm Cart Part No 5H.071.01.0.Pr , Poly V Belt 6Pk 1270 Epdm Cart Part No 5H.071.02.0.Pr , Poly V Belt(6Pk-1295-Epdm) Cart Part No 5H.071.06.0.Pr , Pfm Sensor Air Mass Flow Sensor B Samplevariant Cart Part No 5H.085.04.0.Pr , Dosing Module For 4R1190 Bs4 Cart Part No 5H.085.06.0.00 , Adblue Inlet Line Filter Cart Part No 5H.085.07.0.Pr , Nox Sensor Cart Part No 5H.085.08.0.Pr , Supply Module For 4R1190 Bs4 Cart Part No 5H.085.09.0.Pr , Service Kit; (Dm 3.2) Re-Assembly Kit (Clamp And Seal) Cart Part No 5H.085.10.0.Sp , Nox Sensor Suitable For 24V System Cart Part No 5H.085.11.0.Pr , Urea Filter Cart Part No 5H.085.16.0.Sp , Suction Connection Piece Cart Part No 5H.085.21.0.Sp , Delta P Sensor Cart Part No 5H.085.30.0.Pr , Filter Service Set For 4R1190ta Sm Cart Part No 5H.085.51.0.Sp , Inlet Connector Set For 4R1190ta Sm Cart Part No 5H.085.53.0.Sp , Outlet Connector Set For 4R1190ta Sm Cart Part No 5H.085.54.0.Sp , Backflow Connector Set 4R1190ta Sm Cart Part No 5H.085.55.0.Sp , Rubber Sleeve Between Air Cleaner And Pre Cleaner Cart Part No 5H.086.01.0.Pr , Air Pre-Cleaner Suitable For 4R1190na Engine Cart Part No 5H.086.10.0.Pr , Gas Train Assembly For 4R1190ta Ng1 Png Cart Part No 5H.086.101.0.Pr , Lifting Hook G Esuitable For Bracket Mounting Cart Part No 5H.087.01.0.Pr , Lifting Hook F W Elow Height Cart Part No 5H.087.02.0.Pr , Bracket Air Cleaner Zigzag Welding Cart Part No 5H.089.01.0.Pr , Hose Air Suction Id70xid90 Zigzag Epdm Cart Part No 5H.089.02.0.Pr , Bracket Air Cleaner Zigzag Single Z Shape Cart Part No 5H.089.03.0.Pr , Heat Shield Between Air Cleanerhose And Doc Cart Part No 5H.089.04.0.Pr , Flywheel Assembly Cart Part No 5H.090.20.0.Pr , Thermostat Housing Assembly Opening Upward Cart Part No 5H.091.10.0.Pr , Flywheel Housing Sae Cart Part No 5H.092.01.0.Pr , Flywheel Assembly Cart Part No 5H.093.20.0.Pr , Hose Air Suction Id70xid89 Bend Epdm Cart Part No 5H.095.02.0.Pr , Hose Air Suction Id89xid89 Bend Epdm Cart Part No 5H.095.03.0.Pr , Bracket Air-Pipe Zigzag Welding Cart Part No 5H.095.05.0.Pr , Bracket Alternator Zigzag Single Casting Cart Part No 5H.096.01.0.Pr , Bracket Lub Oil Filter Zigzag Single Cart Part No 5H.097.01.0.Pr , Flywheel Assembly Cart Part No 5H.099.20.0.Pr , Thermostat Assembly Low Mounted Intake Manifold Side Open Cart Part No 5H.102.10.0.Pr , Thermostat Housing Assembly Opening Toward Exhaust And Small Height Cart Part No 5H.105.10.0.Pr , Spacer For Fan Stud Mounting Id9 Od14 L70 Cart Part No 5H.106.01.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.107.02.0.00 , Fuel Pipe Pa12 M14 Banjo Fuel Pump To Fuel Filter Cart Part No 5H.108.02.0.Pr , Element Assembly Safety Cart Part No 5H.109.02.0.00 , Element Assembly Primary Cart Part No 5H.109.03.0.00 , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spout Cart Part No 5H.109.10.0.Pr , Flywheel Assembly Cart Part No 5H.111.10.0.Pr , Pipe Turbo Compressor Out To Cac Cart Part No 5H.112.01.0.Pr , O Ring Id 48X Dia3 Cart Part No 5H.112.02.0.Pr , V Band Clamp Nomdia65 Cart Part No 5H.112.03.0.Pr , Bracket For Turbo Compressor Out Pipe Bend Single Cart Part No 5H.112.04.0.Pr , Ccv Pipe Od63 5At Turbocharger Suction Straight Metallic Cart Part No 5H.112.06.0.Pr , Hose Turbo Air Suction Id6063 5Straight Epdm Cart Part No 5H.112.07.0.Pr , U Clamp For Cac Pipe Support Pipe O D75 Cart Part No 5H.112.08.0.Pr , Clamping Plate For U Clamp Zigzag Single Cart Part No 5H.112.09.0.Pr , Plug Cap 1 827 Nptf For Air Cleaner Restriction Indicator Cart Part No 5H.112.10.0.Pr , Bracket Alternator Zigzag Single Casting Cart Part No 5H.113.01.0.Pr , Hose Air Suction Id127xid63.5 Bend Epdm Cart Part No 5H.114.02.0.Pr , Pipe Cac In Air Presure Id 65 Od 75 Zigzag Casting Al Cart Part No 5H.115.01.0.Pr , Pipe Cac Out Air Presure Od 70 Zigzag Casting Al Cart Part No 5H.115.02.0.Pr , Pipe Cac In Air Presure Id 65 Od 75 Zigzag Casting Al Cart Part No 5H.115.03.0.Pr , Pipe Exhaust Gas Presure Od 88.9 Zigzag Welding Cart Part No 5H.117.01.0.Pr , Bracket Exhaust Pipe Zigzag Single Cart Part No 5H.117.02.0.Pr , Gasket Exhaust Gas Crs 85X4 Diameter 9 Id 89 Ss Cart Part No 5H.117.03.0.Pr , Pipe Oil Filling Presure Od 50 8Thk2 Zigzag Welding Cart Part No 5H.118.01.0.Pr , Hose Oil Filling Presure Id 50 8 Id 60 Straight Epdm Cart Part No 5H.118.02.0.Pr , Spacer For Mounting Fan 10 Mm Width Cart Part No 5H.119.01.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spout Cart Part No 5H.121.10.0.Pr , Bracket Air Cleaner Zigzag Welding Cart Part No 5H.122.01.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.122.02.0.Pr , Hose Air Suction Id70xid70 Zigzag Epdm Cart Part No 5H.122.03.0.Pr , Pipe Air Suction Od70 Metallic Straight Welding Cart Part No 5H.122.04.0.Pr , Pipe Air Suction Id15xod18 Zigzag Metallic Rubber Cart Part No 5H.123.01.0.Pr , Bracket Compressor Air Pipe Flat Single Cart Part No 5H.123.02.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spoutg080747 Cart Part No 5H.124.10.0.Pr , Bracket For Ecu Wiring Harness Interface Connector Support Cart Part No 5H.125.201.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.127.02.0.Pr , Heat Shield Inbetween Alternator And Exhaust Manifold Cart Part No 5H.128.01.0.Pr , Pipe Air Suction Od 88.9 X 88.9 Straight Metallic Cart Part No 5H.132.01.0.Pr , Bracket Air-Pipe Flat Welding Cart Part No 5H.132.03.0.Pr , Air Cleaner Mounting Bracket Cart Part No 5H.133.01.0.Pr , Air Cleaner Assembly (350 Kghr) 90 Deg Bend Outlet I-0 O-41 (Fp-G080754) Cart Part No 5H.133.10.0.Pr , Remote Mounting For Air Suction Restriction Indicator Cart Part No 5H.139.10.0.Pr , Bracket For Scu Mounting Cart Part No 5H.140.06.0.Pr , Bracket For Ccv Cart Part No 5H.140.28.0.Pr , Bellow(Turbo Side) Cart Part No 5H.141.01.0.Pr , Exhaust Pipe (Exhaust Manifold To Bellow) Cart Part No 5H.141.02.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.03.0.Pr , Exhaust Pipe (With Bellow Doc Side ) Cart Part No 5H.141.05.0.Pr , Exhaust Manifold Cart Part No 5H.141.06.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.07.0.Pr , Exhaust Pipe (Turbo To Bellow) Cart Part No 5H.141.08.0.Pr , Exhaust Pipe (Turbo To Doc) Cart Part No 5H.141.11.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.12.0.Pr , Bellow(Turbo Side) Cart Part No 5H.141.21.0.Pr , Joint (B/W Exhaust Pipe And Expansion Bellow) Cart Part No 5H.141.22.0.Pr , Hose For Remote Lub Oil Filter, Pressure, Id 16, M22 Both Side, Bend, Rubber And M Cart Part No 5H.1415.01.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 Both Sidebendrubber And M Cart Part No 5H.1415.02.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 One Side Bendrubber And Met Cart Part No 5H.1415.03.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 Both Sidebendrubber And M Cart Part No 5H.1415.04.0.Pr , Water Out Pipe (Dosing Water Out To Thermostat) Cart Part No 5H.142.03.0.Pr , Hose (Dp Sensor Hps) Cart Part No 5H.143.01.0.Pr , Hose For Dp Sensor (Lps) Cart Part No 5H.143.02.0.Pr , Oil Drain Hose (Ccv To Sump) Cart Part No 5H.143.13.0.Pr , Turbo Out Hose Cart Part No 5H.143.18.0.Pr , Gasket For Exahust Pipe And Doc Cart Part No 5H.144.01.0.Pr , Gasket For Exahust Manifold And Pipe Cart Part No 5H.144.02.0.Pr , Heat Shield For Alternator Cart Part No 5H.144.03.0.Pr , Heat Shield On Expansion Bellow Cart Part No 5H.155.01.0.Pr , Air Cleaner Assembly 50 Deg Bend Outlet Spout Cart Part No 5H.155.20.0.Pr , Ccv_4R1190ta Bsv Cart Part No 5H.163.01.0.Pr , Closed Crankcase Ventilation_Ccv_4R1190na Bsv Cart Part No 5H.163.02.0.Pr , Coalescer Filter Element_Small Coalescer_Ccv_For Bsv & Tier Ivf Engines Cart Part No 5H.163.03.0.Pr , Coalescer Filter Element_Medium Coalescer_Ccv_For Bsv & Tier Ivf Engines Cart Part No 5H.163.04.0.Pr , 12V/3.3Kw Starter Motor With Gear Reduction (Model No. : Stm-27B04) Cart Part No 5H.302.01.0.Pr , 12V Starter Motor S F 4R1190 Bsiv Engine Cart Part No 5H.302.02.0.Pr , Cold Start Kit Bsiv 110Hp Ta Suitable For 5H 43545H 4359 Cart Part No 5H.435.40.0.Sp , Air Cleaner Hose To Turbo Cart Part No 5H.488.01.0.Pr , Adaptor M16 X 1.5 To M14 X 1.5 Cart Part No 5H.488.04.0.Pr , Coolent Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 5H.488.28.0.Pr , Coolent Pipe For (Dosing Module Out To Radiator In-2) Cart Part No 5H.488.29.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No 5H.488.31.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-1) Cart Part No 5H.488.32.0.Pr , Adblue Pipe For (Add Blue Tank Out To Supply Module In) Cart Part No 5H.488.34.0.Pr , Adblue Pipe For (Supply Module Back Flow To Add Blue Tank In) Cart Part No 5H.488.36.0.Pr , Coolent Pipe Forcrankcase Out To Dosing Model In 1 Cart Part No 5H.488.37.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-2) Cart Part No 5H.488.38.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-3) Cart Part No 5H.488.39.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-4) Cart Part No 5H.488.41.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 5H.488.43.0.Pr , Fuel Pipe (Pre Filter To Tank Unit) Cart Part No 5H.488.44.0.Pr , Return Fuel Pipe Cart Part No 5H.488.49.0.Pr , Vci Dongle Only, For Tester Tool Uds Protocol Cart Part No 5H.501.50.0.00 , Industrial Pigtail Harness Cart Part No 5H.501.90.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.510.02.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.510.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.06.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.07.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.08.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.10.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.511.01.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.511.03.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.520.01.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.520.02.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.520.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.520.04.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.530.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.04.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.06.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.08.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.535.01.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.535.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.536.01.0.Sp , High Temperature Sensor Darts200 Aw Id25 Mi54sensata Cart Part No 5H.800.13.0.Pr , Coated Dpf Cart Part No 5H.800.28.0.Pr , Exhaust Gas After Treatmentupward Opening Cart Part No 5H.801.10.0.Sp , Exhaust Gas After-Treatment (20° Downward Opening) Cart Part No 5H.801.20.0.Pr , Exhaust Gas After-Treatment (55° Upward Inlet Opening) Cart Part No 5H.801.30.0.Pr , Gasket Cart Part No 5H.802.04.0.Pr , 4R1190ta Bsv Dosing Mixer Subassembly Cart Part No 5H.802.13.0.Pr , 4R1190 Bsv Dosing Mixer Subassembly Bidding Joint To Mixer Inlet Side Cart Part No 5H.802.14.0.Pr , 4R1190 Bsv Dosing Mixer Subassembly Side Mounted Egt Cart Part No 5H.802.15.0.Pr , Doc Dpf Assembly Cart Part No 5H.802.20.0.Pr , Scr Assembly Cart Part No 5H.802.30.0.Pr , Doc Dpf Assembly Cart Part No 5H.802.50.0.Pr , Scr Assembly Cart Part No 5H.802.60.0.Pr , Connecting Rod End Bearing 4R1190 Cart Part No 5H.999.01.0.Sp , Bsiv Cold Start Kit Till 0 Degree Cart Part No 5H.999.02.0.Sp , Bs Iv Diagnostic Kit Cart Part No 5H.999.05.0.Sp , Bsiv 4R1190 Cold Start Kit For Top Mounted Egt Cart Part No 5H.999.06.0.Sp , Bsiv 1190 Cold Start Kit For Side Mounted Egt Cart Part No 5H.999.07.0.Sp , Bsiv 1190 Cold Start Kit For Side Mounted Nisarg Cart Part No 5H.999.08.0.Sp , Breather Box Cart Part No 5H.999.10.0.Sp , Dynapac Closed Crankcase Ventilation Kit Cart Part No 5H.999.13.0.Sp , Wet Pm Kit (W/O Oil) For 5H.3021 - 4R1190 Cart Part No 5H.999.14.0.Sp , Wet Pm Kit (W/O Oil) For 5H.2001 Cart Part No 5H.999.15.0.Sp , Bs Iv 74.5 Hp Na & Ht Engines Consumables Filter Kit For 50 Hrs, 500 Hrs, And 1500 Hr Cart Part No 5H.999.22.0.Sp , Bs Iv 74.5 Hp Na Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.23.0.Sp , Bs Iv 74.5 Hpht Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.24.0.Sp , Bs Iv 110 Hp Engines Consumables Filter Kit For 500 Hrs And 1500 Hrs Cart Part No 5H.999.25.0.Sp , Bs Iv 110 Hp Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.26.0.Sp , Breather Assembly Kit Cart Part No 5H.999.27.0.Sp , Adblue Inlet Line Filter Cart Part No 5H.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 5H.3008 - 4R1190 Cart Part No 5H.999.30.0.Sp , Wet Pm Kit (W/O Oil ) For 5H.8901 Cart Part No 5H.999.31.0.Sp , Bracket Bsv 4R1190 Wiring Harness Resting Bracket-3 Ht Cart Part No 5H.B074.127.0.Pr , Engine Wiring Harness For Bsv 4R1190 Na1 & Ta-H.T Engines For 74.5 Hp Na1 Cart Part No 5H.E074.110.0.Pr , Engine Wiring Harness For Bsv 4R1190 Ta-H.T 74.5 Hp Ta-Ht(Above Rocker Cover),74. Cart Part No 5H.E074.120.0.Pr , Engine Wiring Harness For Bsv 4R1190 Engines For 110 Hp Ta1 (Top Mounted), Cart Part No 5H.E110.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Na1 & Ta-H.T Engines For 74.5 Hp Na1 Cart Part No 5H.X074.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Na1 Ta H T Engines For 74 5 Hp Na1above Exha Cart Part No 5H.X074.111.0.Pr , Egt Wiring Harness For Bsv 4R1190 Engine Of 74.5 Hp Ta-H.T (Fwh Mounted) Cart Part No 5H.X074.120.0.Pr , Egt Wiring Harness For Bsv 4R1190 Ta1 Engines For 110 Hp (Top Mounted) Cart Part No 5H.X110.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Ta1 Engines For 110 Hptop Mounted Cart Part No 5H.X110.111.0.Pr , Egt Wiring Harness For Bsv 4R1190ta1 Engines For 110 Hp (Fwh Mounted) Cart Part No 5H.X110.120.0.Pr , Nut Cart Part No 60.007.03.0.00 , V Belt : A43 Cart Part No 60.053.01.0.00 , V Belt: A44 Cart Part No 60.060.01.0.00 , V Belt A-45 Cart Part No 60.139.01.0.00 , Governer Spring Cart Part No 61.143.08.0.00 , Strainer Cart Part No 65.073.01.0.00 , Monoblock Crank Case Without Bearings Cart Part No 6H.001.100.0.Pr , Piston Cooling Nozzle Assly Cart Part No 6H.001.17.0.00 , Adapter For Lub Oil Tempswitch Cart Part No 6H.001.21.0.00 , Crankshaft Assly With Bal Wt Cart Part No 6H.002.40.0.00 , Cam Shaft & Gear Assembly Cart Part No 6H.003.10.0.00 , Lube Oil Pump Assly Cart Part No 6H.004.10.0.00 , Suction Tube Cart Part No 6H.006.20.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 6H.007.06.0.00 , Cylinder Head Assly Cart Part No 6H.007.10.0.00 , High Pressure Pipe Assembly Cart Part No 6H.009.70.0.00 , Exhaust Manifold (Finish) Cart Part No 6H.011.01.0.00 , Exhaust Manifold (Side Piece) Cart Part No 6H.011.04.0.00 , Exhaust Manifold (Central Piece) Cart Part No 6H.011.05.0.00 , Spacer Plate (For Turbo Charger) Cart Part No 6H.011.06.0.00 , Assembly Of Adaptor & Pipe Cart Part No 6H.012.03.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.10.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.140.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.50.0.00 , Rocker Cover Gasket Cart Part No 6H.013.15.0.00 , Rocker Cover Cart Part No 6H.013.40.0.00 , Header(For Locooler & Spin On Filter) Cart Part No 6H.014.03.0.00 , Joint: Header Cart Part No 6H.014.11.0.00 , Header & Cooler Assly Cart Part No 6H.014.20.0.00 , Crankshaft Pulley Cart Part No 6H.018.02.0.00 , Extension Pulley (140 Pcd) Cart Part No 6H.018.03.0.00 , Crank Pulley For 6Rt/Ta Pg Engines Cart Part No 6H.018.06.0.Pr , Plate For Stay Cart Part No 6H.019.01.0.00 , Rubber Bush Cart Part No 6H.019.06.0.00 , Steel Bush Cart Part No 6H.019.07.0.00 , Special Washer Cart Part No 6H.019.08.0.00 , Stay For Radiator Cart Part No 6H.019.09.0.00 , Hose: Water Pipe Cart Part No 6H.019.12.0.00 , Stay For Radiator Cart Part No 6H.019.15.0.00 , Joint: Crankcase & Gear Casing Cart Part No 6H.020.04.0.00 , Joint: Crankcase & Gear Cover Cart Part No 6H.020.11.0.00 , Adaptor For Centrifugal Lube Oil Filter Cart Part No 6H.021.01.0.00 , Centrifuge Filter & Adapter Assly Cart Part No 6H.021.10.0.00 , Joint -Centrifugal Filter Adopter Cart Part No 6H.021.11.0.00 , Centrifuge Filter And Adaptor Assembly Cart Part No 6H.021.40.0.00 , Leak Off Pipe Sub Assly Cart Part No 6H.023.10.0.00 , Breather Pipe Cart Part No 6H.024.03.0.00 , Clip For Breather Pipe Cart Part No 6H.024.04.0.00 , Hose: Breather Pipe 32 Id Cart Part No 6H.024.05.0.00 , Breather Extension Pipe Cart Part No 6H.024.06.0.00 , Adaptorfor Breather Pipe Cart Part No 6H.024.10.0.Pr , Joint: Adaptor For Breather Cart Part No 6H.024.11.0.00 , Housing: Exh Outlet Cart Part No 6H.026.01.0.00 , Ss Joint: Turbo Outlet Cart Part No 6H.026.02.0.00 , Bracket For Gas Outlet Manifold Cart Part No 6H.027.01.0.00 , Gas Outlet Manifold Cart Part No 6H.027.02.0.00 , Copper Coated Bolt(M10x025) Cart Part No 6H.027.03.0.00 , Gas Outlet Manifold (6K1080 4V, Cpcb Ii) Cart Part No 6H.027.06.0.00 , Bracket For Air Cleaner Cart Part No 6H.028.01.0.00 , Air Pipe: Air Filter-Turbo In Cart Part No 6H.028.02.0.00 , Bracket For Air Pipe Cart Part No 6H.028.03.0.00 , Joint Ss: Turbocharger Cart Part No 6H.029.01.0.00 , Turbocharger Cart Part No 6H.029.06.0.00 , Turbocharger Cart Part No 6H.029.10.0.00 , Clamp For Cac Pipe Cart Part No 6H.030.03.0.00 , Joint: Air Pipe Cart Part No 6H.030.05.0.00 , Air Pipe(Cac To Inlet) Cart Part No 6H.030.07.0.00 , Air Pipe: Turbo To Cac T/C Side Cart Part No 6H.030.08.0.00 , Air Pipe: Turbo To Cac Cart Part No 6H.030.09.0.00 , Bracket For Air Pipe Cart Part No 6H.030.11.0.00 , Bracket Cart Part No 6H.031.01.0.00 , Pulley: Fan 140 Pcd B Sec Cart Part No 6H.031.03.0.00 , Washer (Fan Drive Pulley) Cart Part No 6H.031.06.0.00 , Bearing Housing Sub Assly Cart Part No 6H.031.10.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No 6H.032.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 6H.032.02.0.00 , Engine Mounting Foot (Ge) Cart Part No 6H.033.01.0.00 , Engine Mounting Foot (Fwe) Cart Part No 6H.033.02.0.00 , Engine Mounting Foot (Gear End Side) Cart Part No 6H.033.13.0.00 , Adaptor For Oil Pipe Cart Part No 6H.034.03.0.00 , Lube Oil Inlet Pipe: K20 Turbo Cart Part No 6H.034.04.0.00 , Lube Oil Drain Pipe: K26 Turbo Cart Part No 6H.034.05.0.00 , Lube Oil Drain Pipe: K26 Turbo Cart Part No 6H.034.11.0.00 , Lube Oil Inlet Pipe: K26 Turbo Cart Part No 6H.034.12.0.00 , Lub Oil Inlet Pipefor Turbocharger Cart Part No 6H.034.13.0.Pr , Lub Oil Drain Pipefor Turbocharger Cart Part No 6H.034.14.0.Pr , Pipe: Thermostat To Radiator Cart Part No 6H.036.03.0.00 , Pipe: Radiator To Pump Inlet Cart Part No 6H.036.04.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 6H.036.11.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 6H.036.13.0.00 , Engine Foot ( Geae End Side ) Cart Part No 6H.038.01.0.00 , Engine Foot ( Flywheel End Side ) Cart Part No 6H.038.02.0.00 , Oil Seal Housing Cart Part No 6H.045.01.0.00 , Joint: Oil Seal Hsg Cart Part No 6H.045.11.0.00 , Lube Oil Pump Assembly Cart Part No 6H.047.150.0.00 , Lube Oil Pump Assly Cart Part No 6H.047.30.0.00 , Damper ( For Applications At 1800 Rpm & Above ) Cart Part No 6H.050.02.0.00 , Extension Pulley (140 Pcd) Cart Part No 6H.050.03.0.00 , Hose: Water Pipe Cart Part No 6H.056.02.0.00 , Vent Pipe For Radiator Cart Part No 6H.056.03.0.00 , Pipe Thermostat To Radiator Cart Part No 6H.057.01.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 6H.057.02.0.00 , Air Pipe (Turbocharger To Inlet) Cart Part No 6H.058.01.0.00 , Joint: Air Pipe Cart Part No 6H.058.02.0.00 , Joint (12 Egt Outlet) Cart Part No 6H.058.16.0.Pr , Joint9 5Egt Inlet Cart Part No 6H.058.17.0.Pr , Exhaust Pipe With Bellow (Turbo To Egt Inlet) Cart Part No 6H.058.23.0.Pr , Set Of Copper Washer - 6R1080 Ta Cart Part No 6H.061.10.0.00 , Set Of Joints - 6R1080ta Cart Part No 6H.061.20.0.Sp , Set Of O-Rings: 6R1080ta 125 Kva Cart Part No 6H.061.30.0.00 , Hose: Waterpump Inlet To Heat Exchanger Cart Part No 6H.062.03.0.00 , High Pressure Pipe Assembly (Integral Sleeve 6.35.Dia) Cart Part No 6H.063.180.0.00 , High Pressure Pipe Assembly Cart Part No 6H.063.80.0.00 , Flywheel Housing Cart Part No 6H.065.01.0.00 , Flywheel Assembly Cart Part No 6H.068.10.0.00 , Fuel Pump Vs Cart Part No 6H.073.01.0.00 , Starter 24V Cart Part No 6H.077.01.0.00 , Adapter For Exhaust Silencer Cart Part No 6H.080.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 6H.081.02.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 6H.081.03.0.00 , Adaptor On Fuel Filter For Fuel Pipes Cart Part No 6H.081.15.0.00 , Crank Pulley Spa,Two Groove,172 Pcd Cart Part No 6H.084.01.0.00 , Bracket For Magnetic Pickup Cart Part No 6H.085.01.0.00 , Woodward Trim Down Pg Plus System For 6 Cylinder Natural Gas Genset Cart Part No 6H.086.10.0.Pr , H Tcable Set For 6 Cylinder Gas Engine Cart Part No 6H.086.34.0.Pr , Gas Train Assembly Cart Part No 6H.086.45.0.Pr , Adaptor For L.O.P.Switch (M14x1.5 -0.125-27 Nptf) Cart Part No 6H.097.01.0.00 , Fuel Injection Pump For 6K1080 Ta (160 Kva) Cart Part No 6H.100.10.0.00 , Camshaft & Gear Assly Cart Part No 6H.1001.10.0.00 , Actuator Cart Part No 6H.1003.01.0.00 , Ecu: Electronic Governor B1 Cart Part No 6H.1003.02.0.00 , Engine Control Unit Cart Part No 6H.1003.04.0.00 , Voltage Suppressor For B12 Ecu Cart Part No 6H.1003.05.0.00 , Flange Heater To Panel Wiring Harness Cart Part No 6H.1005.40.0.00 , Control Panel Assembly For 6K Electronic Governer With Kg 645 Control Panel Cart Part No 6H.1006.60.0.00 , Engine Wiring Harness Assembly With Kg 545 Cart Part No 6H.1008.30.0.00 , Engine Wiring Harness 6R 125Kva Cart Part No 6H.1008.80.0.00 , Engine Wiring Harness Assembly With Kg 545 Cart Part No 6H.1009.80.0.00 , Engine Wiring Harness For A Bank Cart Part No 6H.1011.130.0.Pr , Engine Wiring Harness For B Bank Cart Part No 6H.1011.140.0.Pr , Engine Wiring Harness Cart Part No 6H.1011.20.0.00 , Engine Wiring Harness S F Kg645 Unit 6R Gas Engine Cart Part No 6H.1011.40.0.Pr , Engine Wiring Harness For 6K Emerald Cart Part No 6H.1011.50.0.Pr , Engine Wiring Harness For 6R 62 5 Kva Png Genset Cart Part No 6H.1011.80.0.Pr , Gear Casing For 6K1080 Cart Part No 6H.1013.01.0.00 , Engine Wiring Harness Sf 6R 125Kva Cart Part No 6H.1014.30.0.Pr , Valve Seat Insert: Inlet Cart Part No 6H.1019.07.9.00 , Valve Seat Insert: Exhaust Cart Part No 6H.1019.08.9.00 , Cylinder Head Assembly6k Engine Cart Part No 6H.1019.50.0.00 , Valve Pair Cart Part No 6H.1019.60.0.00 , Mechanical Fuel Level Indicator Cart Part No 6H.1029.02.0.00 , Engine Wiring Harness For 6K Crdi Cpcb 4+ Cart Part No 6H.1043.10.0.Pr , Engine Wiring Harness For 6K Crdi Cpcb 4+ Optiprime 2X200kvaengine B Cart Part No 6H.1043.100.0.Pr , Engine Wiring Harness For 6K 200Kva Cpcb4engine Cart Part No 6H.1043.20.0.Pr , Wiring Harness Assembly For Fuel Pump Added 4K & 6K Genset Cart Part No 6H.1043.60.0.Pr , Engine Heater Wiring Harness Cart Part No 6H.1043.80.0.Pr , Engine Wiring Harness For 6K Crdi Cpcb 4+ Optiprime 2X200kvaengine A Cart Part No 6H.1043.90.0.Pr , Cold Start Kit Main Assembly For L2 Level Application 12V System6k Cart Part No 6H.1046.80.0.Pr , Cold Start Kit Sub Assembly For L2 12V System6k Cart Part No 6H.1046.90.0.Pr , Engine Heater Wiring Harness 6K Cart Part No 6H.1050.20.0.Pr , Lube Oil Sump Cart Part No 6H.1061.05.0.00 , Dipstick Assembly Cart Part No 6H.1061.10.0.00 , Joint: Suction Tube Cart Part No 6H.1062.07.0.00 , Clam For Suction Pipe Cart Part No 6H.1062.09.0.00 , Clamp Support Cart Part No 6H.1062.11.0.00 , Sub Assembly Of Suction Tube Cart Part No 6H.1062.50.0.00 , Delivery Body Cart Part No 6H.1063.01.0.00 , Delivery Tube Cart Part No 6H.1063.02.0.00 , O Ring: Delivery Tube Cart Part No 6H.1063.04.0.00 , Joint: Delivery Body Cart Part No 6H.1063.05.0.00 , Delivery Tube With Adaptors Assembly Cart Part No 6H.1063.06.0.Pr , Delivery Tube With Flange Cart Part No 6H.1063.10.0.00 , Lube Oil Pump Assly Cart Part No 6H.1064.70.0.00 , Lube Oil Pump Int Gear & Bush Assembly Cart Part No 6H.1065.10.0.00 , Crankcase Sub Assembly Cart Part No 6H.1066.140.0.Spr , Piston Cooling Nozzle Assly Cart Part No 6H.1066.60.0.00 , Joint For Header Cart Part No 6H.1081.03.0.00 , Header (For Lub Oil Cooler & Spin On Filter) (Machining) Cart Part No 6H.1081.05.0.00 , Cover Platefor Cooler Header Cart Part No 6H.1081.06.0.Pr , Header (For Common Rail) Cart Part No 6H.1081.07.0.Pr , Header For Lub Oil Cooler And Filter ( S/F Jacket Water Heater) Cart Part No 6H.1081.08.0.Pr , Header And Cooler Assemblycommon Rail Cart Part No 6H.1081.40.0.Pr , Header And Cooler Assemblycommon Rail Cart Part No 6H.1081.60.0.Pr , Lube Oil Cooler Assemblycommon Rail Cart Part No 6H.1081.70.0.Pr , Delivery Tube Cart Part No 6H.1087.01.0.Pr , Clamp Stripfor Delivery Tube Cart Part No 6H.1087.02.0.Pr , Gasket Cylinder Head & Crankcase Cart Part No 6H.1090.02.0.00 , Gasket (Between Cylinder Head & Crank Case) Cart Part No 6H.1090.04.0.Pr , Cyl Head Assemblycomplete6r1080 4 Valves Cart Part No 6H.1090.30.0.Pr , Cyl Head With Valve Guide Valve Seat Insert 4Vcommon Rail Cart Part No 6H.1090.50.0.Pr , Valve Rocker Assembly Cart Part No 6H.1091.50.0.00 , Rocker Box Cart Part No 6H.1092.06.0.00 , Rocker Cover (Finish) Cart Part No 6H.1093.01.0.00 , O Ring (For Rocker Cover) Cart Part No 6H.1093.12.0.00 , Breather Pipe Cart Part No 6H.1093.14.0.00 , Hoseocv To Drain Cart Part No 6H.1093.23.0.Pr , Joint For Air Inlet Manifold - 6R1080 - 4Valves Cart Part No 6H.1094.02.0.00 , Air Inlet Manifold Cart Part No 6H.1094.03.0.00 , Inlet Manifoldfinish Cart Part No 6H.1094.05.0.00 , H P Pipe Assembly 1Pump To Rail6k1080 4V Cart Part No 6H.1096.76.0.00 , Fuel Pipe Feed Pump To Fuel Filter Id 12 X Od 15 Cart Part No 6H.1097.08.0.Pr , Fuel Pipe Fuel Filter To Fip Id 12 X Od 15 Cart Part No 6H.1097.09.0.Pr , Leak Off Pipe Cart Part No 6H.1097.120.0.00 , Leak Off Pipe From Fip To Tank Id 6 X Od 12 -Polyamide Cart Part No 6H.1097.170.0.00 , Crankcasemonoblockwithout Bearings6r1080 4 Valve Cart Part No 6H.1098.50.0.Pr , Camshaft,Thrust Plate And Camgear Sub Assembly Cart Part No 6H.1099.10.0.Pr , Camshaft Assembly Cart Part No 6H.1099.20.0.00 , Camshaft Assembly Cart Part No 6H.1099.55.0.Pr , Recd Pressure Sensor_Ce10010213 Cart Part No 6H.110.03.0.Sp , Relay_24Vdc_Ce10010336 Cart Part No 6H.110.04.0.Sp , Relay_240Vac_Ce10010335 Cart Part No 6H.110.05.0.Sp , Relay Base_Ce10010436 Cart Part No 6H.110.06.0.Sp , Security Seal_2019 Cart Part No 6H.110.07.0.Sp , Siphon_Siphon0.5Inss Cart Part No 6H.110.08.0.Sp , Buzzer With Flasher_Ce10010287 Cart Part No 6H.110.09.0.Sp , Recd Avm -Silicon Pads (Set Of 4) Cart Part No 6H.110.10.0.Sp , Friction Pu Pads ( Set Of 4) Cart Part No 6H.110.11.0.Sp , Recd Pcd Panel_Chkpcd_V2 Cart Part No 6H.110.12.0.Sp , Recd Temperature Sensor_Ce10010029 Cart Part No 6H.110.13.0.Sp , Bush_Ss304, 0.5X0.25 Inch, Bsp Thread Cart Part No 6H.110.14.0.Sp , Socket_Ss, 0.5 Inch, Bsp Thread Cart Part No 6H.110.15.0.Sp , Socket_Ss, 0.25 Inch, Bsp Thread Cart Part No 6H.110.16.0.Sp , Programming Adapter Usb Converter Cart Part No 6H.110.17.0.Sp , Pcd Controller With Harnesss_Ciplpcdv1.0 Cart Part No 6H.110.18.0.Sp , Hub For Motorpal Fip Cart Part No 6H.1100.03.0.Pr , Oil Drain Pipefip To Sump Cart Part No 6H.1100.05.0.Pr , Lub Oil Sumpshallow Cart Part No 6H.1100.09.0.Pr , Fuel Pipefuel Filter To Fip Cart Part No 6H.1100.11.0.Pr , Fuel Pipefeed Pump To Fuel Filter Cart Part No 6H.1100.12.0.Pr , Leak Off Pipeinjector To Tank Cart Part No 6H.1100.13.0.Pr , Leak Off Pipefuel Filter To Tank Cart Part No 6H.1100.14.0.Pr , High Pressure Pipe Assembly Cart Part No 6H.1104.110.0.00 , Small End Bush For 6K1080 Ta (160 Kva) Cart Part No 6H.111.01.0.00 , Leak Off Pipe Assembly Cart Part No 6H.1124.20.0.00 , Leakoff Assly Cart Part No 6H.1124.30.0.00 , Comb Leakoff Pipe Assly Cart Part No 6H.1124.50.0.00 , Exhaust Bend Cart Part No 6H.1126.02.0.00 , Exhaust Silencer(5, Industrial Type) For 6R1080ta Engines For Fire Fighting Appli Cart Part No 6H.1126.03.0.00 , Air Cleaner F.F. Engines Cart Part No 6H.1128.01.0.00 , Hose: Air Cleaner Cart Part No 6H.1128.02.0.00 , Air Cleaner Assembly, S/F Fire Fighting Cart Part No 6H.1128.11.0.00 , Header For Lub Oil Cooler And Filter ( S/F Jacket Water Heater) Cart Part No 6H.113.01.0.00 , Crank Pulley With Poly V Groves Cart Part No 6H.1130.01.0.00 , Fan Drive Pulley (Poly V Section ,140 Pcd) Cart Part No 6H.1130.02.0.00 , Crank Pulley: Poly V Groove Cart Part No 6H.1130.05.0.00 , Crank Pulley Pcd 140, Pcd 143 Cart Part No 6H.1130.08.0.00 , Fan Pulley (Pcd 130) Poly `V, 7 Pk Cart Part No 6H.1130.09.0.00 , Crank Pulley 150 Pcd,Poly V,6Pk Cart Part No 6H.1130.11.0.00 , Crank Pulley (150 Pcd,Poly V,8Pk) Cart Part No 6H.1130.12.0.Pr , Fan Drive Pulley (140 Pcd Poly-V 7Pk) Cart Part No 6H.1130.14.0.00 , Crank Pulley Cart Part No 6H.1130.16.0.00 , Fip For 6R1080ta Firefighting Application Cart Part No 6H.1134.01.0.00 , Turbocharger For 6R1080ta Spp Firefighting Pump Application(K27.2 3371 Olake 15.21) Cart Part No 6H.1135.01.0.00 , Gasket For Turbo Drain Pipe Cart Part No 6H.1135.02.0.Pr , Water Cooled Cac For 6R1080ta Engine(Fire Fig Cart Part No 6H.1142.01.0.00 , Raw Water Pipecac To H E Cart Part No 6H.1142.12.0.Pr , Sticker(Engine Coolant Heater, 2000W) Cart Part No 6H.1143.02.0.00 , Bracket For Heat Exchanger Mtg Cart Part No 6H.1145.01.0.00 , Hose (H.Exchanger To W.Pump) Cart Part No 6H.1145.03.0.00 , Hose (Thermostat To He) Cart Part No 6H.1145.04.0.00 , Hose(Heat Exchanger To W.Pump) Cart Part No 6H.1145.05.0.00 , Exhaust Bend (For K27 Turbo) Cart Part No 6H.1149.02.0.Pr , Fuel Supply Pipe (From Supply Block To Fuel Pump) Cart Part No 6H.1154.02.0.00 , Leak Off Pipe Assembly Cart Part No 6H.1154.40.0.00 , Bracket For Cooling Line Mtg G E Cart Part No 6H.1156.09.0.Pr , Bracket For Cooling Line Mtg F W E Cart Part No 6H.1156.11.0.Pr , Cooling Line(1 1/4, 12V) Assly For Kfp6r-Uf25(6R1080ta) Engines S/F Flow Switch Cart Part No 6H.1156.50.0.00 , Safety Filter Element Cart Part No 6H.1160.01.0.00 , Primary Filter Element Cart Part No 6H.1160.02.0.00 , Hose Reducer (Air Cleaner To Air Pipe) Cart Part No 6H.1160.08.0.00 , Assembly Of Air Cleaner Cart Part No 6H.1160.40.0.00 , Expansion Bellow Cart Part No 6H.1167.01.0.00 , Diffuser Cart Part No 6H.1167.02.0.00 , Joint: Diffuser Cart Part No 6H.1167.05.0.00 , Bracket For Diffuser Cart Part No 6H.1167.06.0.00 , V Belt: 6R1080t/Ta 7Pk Cart Part No 6H.1171.01.0.00 , Poly V Belt (8 Pk 1206 Epdm) Cart Part No 6H.1171.04.0.Pr , Fuel Pipe Feed Pump Outlet Connection Cart Part No 6H.1175.01.0.00 , Fuel Pipe Feed Pump Inlet Connection Cart Part No 6H.1175.02.0.00 , Anti Vibration Mounts Cart Part No 6H.118.01.0.00 , Anti Vibration Mounts Cart Part No 6H.118.02.0.00 , Anti Vibration Mount For Radiator Cart Part No 6H.118.08.0.00 , Oil Supply Pipe Cart Part No 6H.1187.01.0.00 , Drain Pipe Cart Part No 6H.1187.02.0.00 , Turbo Oil Supply Pipe Cart Part No 6H.1187.04.0.Pr , Air Pipe Cart Part No 6H.1188.01.0.00 , Lube Oil Sump Cart Part No 6H.1189.01.0.00 , Exhaust Manifold6r Cart Part No 6H.1190.01.0.00 , Suction Tube (Sub. Assly.) Cart Part No 6H.1191.10.0.00 , Bypass Filter Cart Part No 6H.1193.02.0.00 , Adaptorfor Bypass Filter Cart Part No 6H.1193.04.0.Pr , Koel Green Alternatorkg125 S T Framekg 34 M 4Sae 2 11 5 415V50 Hz0 8 Pf Cart Part No 6H.1213.11.0.Pr , Alternator 125Kva, 415V, 50Hz, 3Ph, 0.8Pf, Sae1/14 Cart Part No 6H.1213.16.0.Pr , Camtone Wheel Cart Part No 6H.1233.02.0.00 , Counter Sunk Socket Headed Screw Cart Part No 6H.1233.03.0.Pr , Cover For Cambore Cart Part No 6H.1233.04.0.Pr , Fuel Pipe Feed Pump To Filter Cart Part No 6H.1249.01.0.00 , Fuel Pipe Filter To Fip Cart Part No 6H.1249.02.0.00 , Bracket For Fuel Filter Cart Part No 6H.1249.03.0.00 , Bracket (For Leak Off Mtg.) Cart Part No 6H.1250.03.0.00 , Leak Off Pipe Cart Part No 6H.1250.04.0.00 , Leak Off Pipe For Fip & Injector Cart Part No 6H.1250.05.0.00 , Oil Supply Pipe (Header To Fip) Cart Part No 6H.1251.03.0.00 , Oil Supply Pipe Cart Part No 6H.1251.18.0.Pr , Gear Casing4v Common Rail Cart Part No 6H.1257.01.0.Pr , Monoblock Crank Case Sub Assly6r1080 4 Valve Cart Part No 6H.1258.80.0.Pr , Turbocharger Cart Part No 6H.127.01.0.00 , Valve Rocker Assly (6K1080 4V,Common Rail) Cart Part No 6H.1301.10.0.Pr , Thermostat Housing Cart Part No 6H.1351.01.0.Pr , Gasketbetween Thermostat Cover Housing Cart Part No 6H.1351.03.0.Pr , Bracket For Gas Outlet Manifold Cart Part No 6H.137.03.0.00 , Housing (For Exhaust Outlet) Cart Part No 6H.138.01.0.00 , Air Pipe (Air Cleaner To Compressor) Cart Part No 6H.139.01.0.00 , Air Pipe (Turbocharger Side - Radiator Cac 800 X 800) Cart Part No 6H.139.02.0.00 , Lube Oil Inlet Pipe Assly:K27 Cart Part No 6H.141.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No 6H.141.20.0.00 , Lub Oil Inlet Pipe For S300 Turbocharger Cart Part No 6H.141.26.0.Pr , Lub Oil Inlet Pipe Assly Cart Part No 6H.141.50.0.00 , Lub Oil Inlet Pipefor Turbocharger Cart Part No 6H.141.70.0.Pr , Lub Oil Drain Pipefor Turbocharger Cart Part No 6H.141.80.0.Pr , Exhaust Manifold (Central Piece) Cart Part No 6H.143.02.0.00 , Nozzle Leak Off Pipe (M12 U) Cart Part No 6H.145.10.0.00 , Pipe: Radiator-Pump Inlet Cart Part No 6H.146.11.0.00 , Cylinder Head Assembly Cart Part No 6H.147.20.0.00 , Cylhead Assemblyp Type Cart Part No 6H.147.50.0.00 , Cylhead With Valve Guide And Insertss Type Cart Part No 6H.147.60.0.00 , Cylhead Assemblyp Type Cart Part No 6H.147.70.0.Pr , Injector Cart Part No 6H.155.10.0.00 , Air Delivery Pipe For Ural 375D Cart Part No 6H.165.01.0.00 , Cold Start Kit 6R (L3) Cart Part No 6H.1684.10.0.Sp , Cable Gland Assembly For 6K Engine. Cart Part No 6H.1686.10.0.Pr , Water Connection Hose Pipe Hotstart To Radiator -125 Kva Cart Part No 6H.172.21.0.00 , Water Connection Hose Pipe Hotstart To Engine -125 Kva Cart Part No 6H.172.22.0.00 , Hose: Make Up - 1000 Core Radiator Cart Part No 6H.172.28.0.00 , Con Rod Bearing (Upper) Cart Part No 6H.179.13.0.Pr , Con Rod Bearinglower Cart Part No 6H.179.14.0.Pr , Connecting Rod Assly (With Small End Bush) Cart Part No 6H.179.30.0.Pr , Con Rod Assembly Cart Part No 6H.179.50.0.Pr , Damper Cart Part No 6H.186.01.0.00 , Fuel Pump: 6R1080t V.S. Cart Part No 6H.188.10.0.00 , Fuel Filling Hose For 125 Kva Trailer Mounted Genset Cart Part No 6H.192.04.0.00 , Lfl Sensor ( Low Fuel Level ) 165 Mm Hight Cart Part No 6H.192.14.0.00 , Fuel Injection Pump :6R1080ta-Pg Cart Part No 6H.195.10.0.00 , Fuel Injection Pump For 6R1080t-Pg Cart Part No 6H.196.10.0.00 , Control Panel Schematic For 160Kva, 3Ph With Kg645 Ip+A Cart Part No 6H.2003.70.0.Pr , Control Panel Cart Part No 6H.2003.95.0.Pr , Power Panel Cart Part No 6H.2004.50.0.Pr , Engine Control Panel To Alternator Harness (Fot C.T. & 3Ph. Supply Conn.) Cart Part No 6H.2024.20.0.00 , Ct Wiring Harness For A Bank Cart Part No 6H.2024.80.0.Pr , Ct Wiring Harness For B Bank Cart Part No 6H.2024.90.0.Pr , Inlet Manifold Cart Part No 6H.204.03.0.00 , Rocker Cover Cart Part No 6H.222.10.0.00 , Subassembly Of Suction Tube Cart Part No 6H.224.30.0.00 , Joint: Gear Casing Cart Part No 6H.225.02.0.00 , Camshaft Gear Cart Part No 6H.226.02.0.00 , Thrust Plate Cart Part No 6H.226.03.0.00 , Camshaft, Thrust Plate & Camgear Sub Assly Cart Part No 6H.226.10.0.00 , Lube Oil Sump Cart Part No 6H.227.01.0.00 , Crankshaft Pulley Cart Part No 6H.228.01.0.00 , Front Cover Cart Part No 6H.229.01.0.00 , Monoblock Crankcase Without Bearing Cart Part No 6H.233.120.0.Pr , Crankcase With M Bcaps6h 233 90 0 Pr Cart Part No 6H.233.90.0.Sp , Piston Pin 42.1 Mm Dia For 6K1080ta Cart Part No 6H.247.14.0.00 , Piston Ring Set Cart Part No 6H.247.30.0.00 , Piston Assembly Cart Part No 6H.247.50.0.00 , Piston Assembly Cart Part No 6H.247.60.0.00 , Intermediate Gear Support S F Auto Timer Cart Part No 6H.267.01.0.00 , Gear Casing Cart Part No 6H.273.03.0.00 , Suction Tube Assly Cart Part No 6H.286.10.0.00 , Rotary Fip For 6R1080ta4 Engine169 Hp 2300 Rpm Cart Part No 6H.295.03.0.00 , Rotary Fip: 6R1080ta3 115Hp @ 2300Rpm Cart Part No 6H.295.05.0.00 , Rotary Fip For 6R1080ta1 Engine125 Hp 2300 Rpm Cart Part No 6H.295.07.0.00 , Radiator For 6R1080ta Canopied Genset With Stoneguard Cart Part No 6H.309.20.0.00 , Gear Casing ( For Fmul Engine ) Cart Part No 6H.311.04.0.00 , Con Rod Assly With Se Bush Cart Part No 6H.322.50.0.00 , Coupling 0.37Rb Cart Part No 6H.326.10.9.00 , Fan: 21 Pusher Met Cart Part No 6H.330.01.0.00 , Exh Manifold K27 Turbo Lagged (6H.143.01.0) Cart Part No 6H.342.01.0.00 , Breather Hose Cart Part No 6H.345.04.0.00 , Silencer Cart Part No 6H.352.01.0.00 , Joint: Exhaust Silencer Cart Part No 6H.352.02.0.00 , Flange( At Silencer Inlet And Outlet ) For 6R1080t And 6R1080ta Silent Set Cart Part No 6H.352.03.0.00 , Front Cover Cart Part No 6H.357.01.0.00 , Fan Adaptor Cart Part No 6H.360.01.0.00 , Hose Reducer For Turbo Cart Part No 6H.366.01.0.00 , Hose Silicone 3 For Cac Pipe Cart Part No 6H.366.03.0.00 , Lub Oil Sump (Shallow) Cart Part No 6H.378.01.0.00 , Dipstick Assembly Cart Part No 6H.378.20.0.00 , Crankshaft Assembly Cart Part No 6H.387.20.0.00 , Crankshaft Assembly (With Crank Gear) Cart Part No 6H.387.30.0.00 , Turbocharger For 6K1080ta 4V Cpcb Ii Engine Cart Part No 6H.391.01.0.00 , Turbocharger(For 6K-140 Kva Engine) K27 2964 Mxa 10.21 Cart Part No 6H.391.10.0.00 , Fip:6K1080 Ta Cpcbii Cart Part No 6H.394.02.0.00 , Inline Fip Ea40 2896 00For 6R1080 T150hp 1900Rpmcpcbii Engine Cart Part No 6H.394.03.0.00 , 4440 Motorpal Fipfor 6R1080ta 3000Rpm Cpcb Ii Engine Cart Part No 6H.394.05.0.Pr , Safety Air Filter Element Cart Part No 6H.411.01.0.00 , Primary Air Filter Element Cart Part No 6H.411.02.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No 6H.411.10.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No 6H.411.20.0.00 , Straight Rubber Hose Cart Part No 6H.412.03.0.00 , Hose For Air Suction Pipe Cart Part No 6H.412.06.0.00 , Air Cleaner Assly Wo Elemt Cart Part No 6H.412.10.0.00 , Hose: Air Cleaner Cart Part No 6H.412.11.0.00 , Hose: Air Cleaner Cart Part No 6H.412.12.0.00 , Air Cleaner Primary Element Cart Part No 6H.413.02.0.00 , Radial Seal Air Cleaner Assly,15 Cu Meter Cart Part No 6H.413.10.0.00 , Air Cleaner Assembly Cart Part No 6H.413.30.0.00 , Air Filter Primary Cart Part No 6H.413.32.0.00 , Piston Cooling Nozzle Assly Cart Part No 6H.426.10.0.00 , Dial Type Mechanical Fuel Level Gauge275mm Ht Cart Part No 6H.457.05.0.00 , Hose: Air Cleaner Cart Part No 6H.466.47.0.00 , Spacer For Starter Cart Part No 6H.466.51.0.00 , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No 6H.477.101.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No 6H.477.102.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No 6H.477.103.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No 6H.477.104.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) Cart Part No 6H.477.106.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Cart Part No 6H.477.107.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No 6H.477.108.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No 6H.477.109.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No 6H.477.111.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No 6H.477.112.0.Pr , Bracket Assembly For Pipe Clamping On Dosing Module Cart Part No 6H.477.113.0.Pr , Fuel Inlet Pipe (Tank To Pre-Filter) Cart Part No 6H.477.114.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No 6H.477.117.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2 Cart Part No 6H.477.118.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 5 Cart Part No 6H.477.119.0.Pr , O-Ring Cart Part No 6H.477.140.0.Sp , Filler Filter Cart Part No 6H.477.141.0.Sp , Drain Plug Cart Part No 6H.477.142.0.Sp , Air Vent Cart Part No 6H.477.143.0.Sp , Filling Neck Cart Part No 6H.477.144.0.Sp , Locking Cap Cart Part No 6H.477.145.0.Sp , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 6H.477.15.0.00 , Aluminium Radiator Assly Cart Part No 6H.477.22.0.00 , Aluminium Radiator Assembly Cart Part No 6H.477.23.0.00 , Recovery Bottel 3 5 Ltrs Cart Part No 6H.477.26.0.Pr , 25L Ad Blue Tank Assembly Cpcb4 Cart Part No 6H.477.27.0.Pr , Metalic Pipe Thermostat To Rad In Cart Part No 6H.477.31.0.00 , Hose From Radiator To Pipe Cart Part No 6H.477.32.0.00 , Hose For Make Up Connection Cart Part No 6H.477.33.0.00 , Clamp For 160 Kva Cart Part No 6H.477.37.0.00 , Plate Cart Part No 6H.477.38.0.00 , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No 6H.477.47.0.Pr , Fan 30`` Cart Part No 6H.477.52.0.Pr , Aluminium Radiator Assembly Cart Part No 6H.477.53.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No 6H.477.94.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No 6H.477.96.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 1 Cart Part No 6H.477.97.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 3 Cart Part No 6H.477.98.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 6H.477.99.0.Pr , Engine Mounting Foot (Gear End Side) For 6R1080 Gas Genset Cart Part No 6H.487.01.0.00 , Air Cleaner Wo Safty Elemt 6M3 Cart Part No 6H.488.10.0.00 , Aluminium Radiator: 6R1080ta Cart Part No 6H.501.10.0.00 , Hose: Make Up Connection Cart Part No 6H.502.02.0.00 , Hose For Radiator Out To Water Pump In Cart Part No 6H.502.11.0.00 , Stay Rod (For Radiator) Cart Part No 6H.502.12.0.00 , Hose Thermostat To Radiator Inlet (45X45x155l) Cart Part No 6H.502.13.0.00 , Radiator Cart Part No 6H.502.40.0.00 , Lower Clamp For New Gear Casing6h 972 Cart Part No 6H.504.11.0.00 , Main Fuel Filter Cart Part No 6H.508.03.0.Pr , Pre Fuel Filter Cart Part No 6H.508.04.0.Pr , 6H 508 05 0 Pr Cartridge For Filter 6H 508 03 0 Pr 083689901 D 01 Cart Part No 6H.508.05.0.Pr , 6H 508 06 0 Pr Cartridge For Filter 6H 508 04 0 Pr E083689902 D 01 Cart Part No 6H.508.06.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No 6H.508.16.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 6H.508.17.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 6H.508.18.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 6H.508.19.0.Sp , Cac Outlet Pipe Stage 1Cac To Inlet Manifold S F Schwing Bp2800 Cart Part No 6H.510.03.0.Pr , Cac Outlet Pipe Cac To Inlet Manifold Stage 2 Cart Part No 6H.510.04.0.00 , Rubber Hose For Cac Inlet Pipe Cart Part No 6H.510.07.0.00 , Rubber Hose For Cac Outlet Pipe Cart Part No 6H.510.08.0.00 , Radiator &Cac Assembly.(S/F - Schwing C.P) Cart Part No 6H.510.10.0.00 , Water Pipe Thermostat To Radiator Cart Part No 6H.510.11.0.00 , Stay For Radiator Cart Part No 6H.510.12.0.00 , Air Pipe (Turbocharger To Cac) Cart Part No 6H.516.01.0.00 , Air Pipe (Cac To Air Inlet) Cart Part No 6H.516.02.0.00 , Air Pipe Bend Pipe To Radiator Cart Part No 6H.516.04.0.00 , Air Pipe Cart Part No 6H.516.08.0.00 , Cac Pipe Cold Side Cart Part No 6H.516.21.0.Pr , Engine Wiring Harness Assembly Cart Part No 6H.520.10.0.00 , Set Of Joints Cart Part No 6H.522.40.0.Sp , Radiator Fan (22) Cart Part No 6H.540.01.0.00 , Expansion Bellow Cart Part No 6H.541.01.0.00 , Exhaust Bend (S/F- Schwing) Cart Part No 6H.546.01.0.00 , Spacer: Silencer - Turbocharger Cart Part No 6H.548.04.0.00 , Joint:Spacer & Silencer Cart Part No 6H.548.05.0.00 , Assembly Exhaust Silencer 6R1080ta Bs Iii Cart Part No 6H.548.10.0.00 , Silencer Clamp- 275 Dia Cart Part No 6H.553.21.0.00 , Fan Assly:22.5/6-6/2Zr/40/Pag/Pusher Cart Part No 6H.554.10.0.00 , Coolant Level Sensor For 6K Crdi Cart Part No 6H.565.13.0.00 , Breather Hose Cart Part No 6H.599.02.0.00 , Pipe Metallicfrom Air Cleaner To Tc Cart Part No 6H.599.04.0.00 , Hose: Air Cleaner Cart Part No 6H.599.05.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 6H.599.11.0.00 , Fuel Return Pipe Cart Part No 6H.599.12.0.00 , Actuator & Ecu Mtg. Bracket Cart Part No 6H.599.13.0.00 , Fuel Pipe Feed Pump To Pre-Filter Cart Part No 6H.599.14.0.00 , Drain Pipe Cart Part No 6H.599.15.0.00 , Link M6x1 Cart Part No 6H.599.17.0.00 , Hose: Radiator Inlet Cart Part No 6H.599.21.0.00 , Radiator Outlet Hose Cart Part No 6H.599.22.0.00 , Fuel Pipe (Pre-Filter To Tank Unit Cart Part No 6H.599.23.0.00 , Fuel Pipe From Feed Pump To Pre Filter Cart Part No 6H.599.24.0.00 , Fuel Pipe From Feed Pump To Pre Filter Cart Part No 6H.599.29.0.Pr , Suction Hose Cart Part No 6H.599.36.0.Pr , Pvc Pipe For Air Cleaner Cart Part No 6H.599.42.0.Pr , Radiator Outlet Hose Cart Part No 6H.599.43.0.Pr , Bracket For Stop Solenoid Mtg. Cart Part No 6H.599.46.0.Pr , Linkm6 Cart Part No 6H.599.48.0.Pr , Fuel Inlet Pipe Cart Part No 6H.599.51.0.Pr , Fuel Inlet Pipeboth Side Union Nut Cart Part No 6H.599.53.0.Pr , Fuel Return Pipe Cart Part No 6H.599.74.0.Pr , Junction Box Support Bracket Cart Part No 6H.599.76.0.Pr , Fuel Pipe (From Tank To Nrv) Cart Part No 6H.599.84.0.Pr , Fuel Pipe (From Nrv To Pre-Filter) Cart Part No 6H.599.86.0.Pr , Kit For Electrical Fuel Feed Pump Fitment In 6K Cart Part No 6H.599.90.0.Sp , Wiring Harnessassembly For Starter Side Panel Cart Part No 6H.610.10.0.00 , Exhaust Silencer Cart Part No 6H.621.10.0.00 , Rh Lock With Catcher: 50Mm Thk Cart Part No 6H.623.25.0.00 , Lh Lock With Catcher: 50Mm Thk Cart Part No 6H.623.30.0.00 , Fuel Pump Gear Cart Part No 6H.652.01.0.00 , Hub For Motorpal Fip Fitment Cart Part No 6H.652.02.0.00 , Starter 12V 3Kw Cart Part No 6H.675.01.0.00 , Control Relay Cart Part No 6H.715.11.0.00 , Exhaust Temperature Sensor With 2Pin Connector, Cart Part No 6H.715.31.0.00 , Koel Green Alternatorkg 50 S Tframe Ls Kg423ksae 3 11 5 415 V50 Hz0 8 Pf Cart Part No 6H.801.05.0.Pr , Current Transformer(Set Of 3 Ct) 300/5A For Frame 254 Cart Part No 6H.831.09.0.00 , Fanhpd Rating 70 160 Kva Ag3141890000 Frame Kg44 3 Cart Part No 6H.831.16.0.00 , Wound Exciter Rotor Scl35rating 50 Kva 1Ph82 5 100 Kva Cart Part No 6H.831.17.0.00 , Wound Exciter Stator Scl35rating 50 Kva 1Ph 82 5 100 Kva Cart Part No 6H.831.18.0.00 , Wound Exciter Rotorrating 62 5 Kva 1 Ph125 160 Kva Cart Part No 6H.831.19.0.00 , Wound Exciter Stator-Lcl 50, Rating-62.5 Kva 1Ph, 125-160 Kva, (Sem443st004b), Fram Cart Part No 6H.831.21.0.00 , Diode Assembly Rating 70 60Kvaaem000re137bframe Kg44 3 Cart Part No 6H.831.22.0.00 , Nde End Shieldrating 70 160 Kva Ag2140080000 Frame Kg44 3 Cart Part No 6H.831.26.0.00 , Coupling Disc11 5Rating 70 160 Kva Pde352da021b Frame Kg44 3 Cart Part No 6H.831.27.0.00 , Avr- D350 Cart Part No 6H.831.30.0.00 , R450 To D350 Retro Fitment Kit For Kg45 Frame Cart Part No 6H.831.40.0.00 , Mccb 3 Pole125a Cart Part No 6H.846.05.0.00 , Relay Board 4 Channel Cart Part No 6H.846.06.0.00 , Relay Board 4Ch, 2 C/O,24 Vdc Cart Part No 6H.846.07.0.00 , Relay 100 Amp.Type- Bgr 213/24Vdc Cart Part No 6H.846.35.0.00 , Battery Charger: 10A 24 Vdc Cart Part No 6H.849.09.0.00 , 4 Pin Connector3102r 14S 2 P Sqg C C Cart Part No 6H.849.31.0.00 , Generator Control Unit Model Dse 4522 A2 Cart Part No 6H.877.14.0.Pr , On/Ff Selector Sw. Cart Part No 6H.880.12.0.00 , Emergency Stop Pb With Nc Element Cart Part No 6H.880.13.0.00 , Door Lock, Type-Dm3wl / Equiv - Die Cast , Standard Grip 30Mm Cart Part No 6H.880.16.0.00 , On/Ff Selector Sw.(With No Element ) Cart Part No 6H.880.32.0.00 , On/Off Selector Switch With No Element Cart Part No 6H.880.41.0.00 , Emg Stop With No Element Cart Part No 6H.880.42.0.00 , Emg Stop With Nc Element Cart Part No 6H.880.43.0.00 , 1Ncs2 Element Cart Part No 6H.880.45.0.00 , Avr-Mx 321 Type For Stamford Alternator 160 Kva At Ntp, 415 Volts, 50 Hz, 3 Phase, Cart Part No 6H.892.06.0.00 , Air Cleaner Mounting Bracket Cart Part No 6H.899.01.0.00 , Hose: Air Cleaner Cart Part No 6H.899.02.0.00 , Wiring Harness Asys F 6R1080ta125 Kva Cart Part No 6H.900.10.0.00 , Koel Green Alternatorkg160 S T Framel Kg 44 3 H Sae 2 11 5 415V50 Hz0 8 Pf Cart Part No 6H.901.03.0.Pr , Diode Assembly Kg 45 Cart Part No 6H.901.11.0.00 , Wound Exciter Rotor Kg 45 Cart Part No 6H.901.12.0.00 , Wound Exciter Stator Kg 45 Cart Part No 6H.901.13.0.00 , Terminal Bar For Kg 45 Cart Part No 6H.901.14.0.00 , Coupling Disc 14For Kg 45 Cart Part No 6H.901.17.0.00 , Nde Shield For Kg 45 Cart Part No 6H.901.21.0.00 , Koel Green Alternatorcoastalhumid Environment Kg160 S T Framel Kg 44 3 H Cart Part No 6H.901.28.0.Pr , De Adaptor Kg 40 (Sae 2) Cart Part No 6H.901.32.0.00 , Droop Current Transformer Kg 47.2 Cart Part No 6H.901.34.0.00 , 23-Pin Connector Ms-3102-R-32-6-P (Male Type Pins)+C&C+Sqg Cart Part No 6H.902.25.0.00 , Wiring Haness Assembly (Fire Fighting) Cart Part No 6H.902.30.0.00 , Temperature Switch Engine Coolant Cart Part No 6H.902.31.0.00 , Temperature Switch Engine Coolant Low Cart Part No 6H.902.32.0.00 , Temperature Switch Raw Water Cart Part No 6H.902.33.0.00 , Wiring Harness Assembly 6R1080ta Fm_Ul New Cart Part No 6H.902.35.0.00 , Flow Switch 4Rta Cart Part No 6H.903.11.0.Pr , Raw Water Flow Switch R1080ta Fm_Ul New Cart Part No 6H.903.13.0.Pr , Raw Water Flow Switch Sl90 Fm Ul New Cart Part No 6H.903.14.0.Pr , Engine Wiring Harness: 6R Cpcb Cart Part No 6H.924.20.0.00 , Wiring Harness (For Kpc 6H.2575) Cart Part No 6H.931.40.0.00 , Common Rail For 6K1080tae Project Cart Part No 6H.9408.01.0.00 , Hose: Air Cleaner Cart Part No 6H.949.02.0.00 , H T Cable Set Cart Part No 6H.956.13.0.00 , Distributor Driving Shaft For 6R Gas Engine Cart Part No 6H.956.28.0.00 , Gear Casing Cart Part No 6H.972.01.0.00 , Power Cables For A Bank Cart Part No 6H.977.130.0.Pr , Power Calbes For B Bank Cart Part No 6H.977.140.0.Pr , Canopy Wiring Harness For Optiprime 2 X 200Kva Cpcb4 Genset Cart Part No 6H.979.90.0.Pr , Current Transfarmor 200/5, 5 Va Cart Part No 6H.980.05.0.00 , Single Pole Mcb 16A Cart Part No 6H.983.11.0.00 , Shaft For Lube Oil Pump Intermediate Gear Cart Part No 6H.985.07.0.00 , Lube Oil Pump Assly Cart Part No 6H.985.30.0.00 , Joint: Suction Flange Cart Part No 6H.986.05.0.00 , Sub Asm Of Suction Tube Cart Part No 6H.986.30.0.00 , Funnel Filter Cart Part No 6H.986.31.0.00 , Funnel Filter 55 Lpm Cart Part No 6H.986.32.0.Tol , Funnel Filter 18.9 Lpm Cart Part No 6H.986.34.0.Sp , Gasket (Between Bearing Housing And Pump Volute) Cart Part No 6H.990.07.0.Pr , Gasketbet Crankcase And Pump Volute Cart Part No 6H.990.08.0.Pr , Pulley (For Water Pump) Cart Part No 6H.990.09.0.Pr , Water Pump Aasembly Cart Part No 6H.990.20.0.Pr , Fuel Pump 6R1080tc 169 Hp @ 2300 Rpm_F 002 Aoz 651 Cart Part No 6H.996.02.0.00 , Modification Kit For Oil Fuel Mixing Issue Cart Part No 6H.999.02.0.Sp , Main Bearing Kit For Bio Gas Cart Part No 6H.999.03.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3553... - 6R1080ta Cart Part No 6H.999.07.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8419... - 6K1080ta G2 Cart Part No 6H.999.08.0.Sp , Wet Pm Kit (W/O Oil) For 6H.2516 - R 1080 Ta Cart Part No 6H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8303, 6H.8416 Cart Part No 6H.999.23.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3415, 6H.3531, 6H.3532, 6H.3533 - 6R1040 Cart Part No 6H.999.24.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3416, 6H.3445, 6H.3545, 6H.3552 - 6R1040 Cart Part No 6H.999.25.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3545 - 6R1080ta Cart Part No 6H.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8404,6H.5255, 6H.9460, 6H.9467, 6H.5245,- 6K1080ta G2 Cart Part No 6H.999.49.0.Sp , Wet Pm Kit (W/O Oil) For 6H.4435, 4H.3423, 6H.3532- 6R1080ta Cart Part No 6H.999.58.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3501 - 6R1080ta Cart Part No 6H.999.59.0.Sp , Major Overhal Kit For 6R1080 Bsiii Cart Part No 6H.999.60.0.00 , Wet Pm Kit (W/O Oil) For 6H.8425 - 6K1080ta G2 Cart Part No 6H.999.67.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8422 - 6K1080ta G2 Cart Part No 6H.999.68.0.Sp , Wet Pm Kit (W/O Oil) For 6H.5045, 6H.5245 - 6K1080 Cart Part No 6H.999.70.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3502..., 6H.2501... - 6R1080ta Cart Part No 6H.999.96.0.Sp , Doc Catalyst9 5Dia X 5Length15 G Cft5 1 Pt Pdfresh Cart Part No 6H.Egt4.10.0.Pr , 9 5Gasket Doc To Mixer 82429423 Cart Part No 6H.Egt4.23.0.Pr , Supply Module B444 606 940Sm 2 2 Evo Bl12 V9 Bar Cart Part No 6H.Egt4.24.0.Pr , 6H Egt4 28 0 Pr 9 5Egt System Assemblycpcb 4 Cart Part No 6H.Egt4.28.0.Sp , Wire Braided Pipe From Jacketed Leakoff To Fuel Collector Cart Part No 6H.M005.03.0.00 , Fuel Pipefuel Filter To Fuel Pump Cart Part No 6H.M081.02.0.00 , Fuel Pipefeed Pump To Fuel Filter Cart Part No 6H.M081.03.0.00 , Hose Thermostat To He Cart Part No 6H.M400.05.0.00 , Hose Thermostat To He Cart Part No 6H.M400.06.0.00 , Hose Between Cac Out To He In Cart Part No 6H.M400.72.0.00 , Heat Exchanger For 6R Fishing Engine Cart Part No 6H.M409.01.0.00 , Heat Exchanger For 6R Fishing Engine D101 Cart Part No 6H.M409.12.0.00 , Air Cleaner Model Jjm 02 Cart Part No 6H.M412.05.0.00 , K Sealent (80 Ml) Cart Part No 82.060.10.0.80 , Rust Buster Cart Part No 82.060.10.0.92 , Genset Alternator De/Nde Bearing Grease (500 Gm) For Power Car Application Cart Part No 82.170.50.0.50 , Mechnical Inter Lock Cart Part No Acl.0001.007.0.00 , Surge Suppressor Koel Make For Frame 1 Cart Part No Acl.0001.008.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Top For Frame 1 , Koel Make (Type : Ku Cart Part No Acl.0001.110.0.00 , Mechnical Inter Lock Cart Part No Acl.0002.007.0.00 , Surge Suppressor , Koel Make For Frame 2( Type: Kas-3 ) Cart Part No Acl.0002.008.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Top For Frame 2 , Koel Make (Type : Ka Cart Part No Acl.0002.110.0.00 , Mechnical Inter Lock Koel Make For Frame 3Typekar 180 Cart Part No Acl.0003.007.0.00 , Contactor Auxillary Cart Part No Acl.0003.220.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Side For Frame 4 Koel Maketype Ka Cart Part No Acl.0004.110.0.00 , Mccb Auxuliary Shunt Release Contact Upto 100 Amp Koel Make For Type Kll1 Cart Part No All.0100.003.0.00 , Mccb Spreaders 100 125Amp3 Polekoel Make For Type Kll1 Set Of 6With Hardw Cart Part No All.0100.036.0.00 , Mccb Spreaders 100 Amp, 4 Pole, Koel Make For Type Kll1 ( Set Of 8) With Hardwar Cart Part No All.0100.046.0.00 , Mccb Auxuliary Shunt Release Contact 125-250 Amp Cart Part No All.0250.003.0.00 , Mccb Spreaders 250 Amp, 3 Pole Cart Part No All.0250.036.0.00 , Mccb Spreaders 250 Amp4 Polekoel Make For Type Kll3 Set Of 8With Hardware Cart Part No All.0250.046.0.00 , Mccb Auxuliary Shunt Release Contact 400-800 Amp Cart Part No All.0800.003.0.00 , Mccb Rotary Handle Koel Make, For Type Kll5 Cart Part No All.0800.005.0.00 , Mccb Spreaders 800 Amp3 Polekoel Make For Type Kll5set Of 6With Hardware Cart Part No All.0800.036.0.00 , Mccb Rotary Handle Koel Make, For Type Kll6 Cart Part No All.1250.005.0.00 , Regulating Sway Bar Cart Part No Ap1.001.12.0.Pr , Oil Safeguard Switch Cart Part No Ap1.001.15.0.Pr , Oil Level Switch Assembly Cart Part No Ap1.001.20.0.00 , Governor Gear Cup Assy Cart Part No Ap1.001.30.0.00 , Front Oil Seal 25X41 25X6 Cart Part No Ap1.002.02.0.00 , Crancase Cover Gasket Cart Part No Ap1.002.04.0.00 , Dipstick With Seal Cart Part No Ap1.002.06.0.Pr , Cylinder Head Gasket Cart Part No Ap1.003.05.0.00 , Exhaust Gasket Cart Part No Ap1.003.06.0.00 , Cylinder Head Assembly Cart Part No Ap1.003.10.0.00 , Pusher Cart Part No Ap1.005.06.0.Pr , Starter Motor Solenoid Cart Part No Ap1.006.04.0.00 , Starter Motor Assembly Cart Part No Ap1.006.10.0.00 , Recoil Starter Assembly Cart Part No Ap1.007.20.0.Pr , Filter Element Cart Part No Ap1.008.02.0.00 , Air Cleaner Assembly Cart Part No Ap1.008.10.0.00 , Filter Element Cart Part No Ap1.008.11.0.00 , Alternator Fan Cart Part No Ap1.009.03.0.00 , Rotor Fan Cart Part No Ap1.009.121.0.Pr , Alternator Rear Frame Cart Part No Ap1.009.15.0.00 , Voltage Regulator- 2 Kva Cart Part No Ap1.009.42.0.00 , Rotor Rear Fan Cart Part No Ap1.009.44.0.Pr , 2 6Kw Pm Alternator Assembly Cart Part No Ap1.009.55.0.Pr , Pm Alternator Module Cart Part No Ap1.009.64.0.Pr , Ignition Coil Cart Part No Ap1.010.01.0.00 , Ignition Coil Assembly Cart Part No Ap1.010.10.0.00 , Charge Coil Assembly Cart Part No Ap1.010.20.0.Pr , Muffler Cart Part No Ap1.011.01.0.00 , Catcon Element Cart Part No Ap1.011.18.0.Pr , Muffler For 2.8Kw Pmg Cart Part No Ap1.011.22.0.00 , Exhaust Gasket Muffler Cart Part No Ap1.011.29.0.Pr , Catcon & Catcon Pipe Assly For 2.6Kw Ccp196 (S/F Pmg Kcc) Cart Part No Ap1.011.45.0.Spr , Catcon And Catcon Pipe Assembly Cart Part No Ap1.011.50.0.Spr , Anti Vibration Mount708a Mix 01 Yellow 15 4 To 5 Alternator Side Cart Part No Ap1.012.01.0.Pr , Anti Vibration Mount708a Mix 02 Green 25 4 To 5 Engine Side Cart Part No Ap1.012.02.0.Pr , Piston Assembly Cart Part No Ap1.013.10.0.Pr , Carburetor Assembly Cart Part No Ap1.014.10.0.00 , Carburettor Metal Gasket Cart Part No Ap1.014.12.0.00 , Carburettor Connecting Block Gasket Cart Part No Ap1.014.13.0.00 , Carburettor Connecting Block Cart Part No Ap1.014.14.0.00 , Carburettor Metal Gasket Cart Part No Ap1.014.15.0.00 , Fine Regulating Spring Cart Part No Ap1.015.04.0.Pr , Back Spring Cart Part No Ap1.015.05.0.Pr , Ignition Switch Cart Part No Ap1.016.03.0.00 , Mcb 9 Amp Cart Part No Ap1.016.08.0.00 , Engine Power Harness For 2 8Kw Pmg Petrol Cart Part No Ap1.016.45.0.Pr , Regulator Charger Cart Part No Ap1.018.04.0.Pr , Fuel Gauge Cart Part No Ap1.022.05.0.00 , Fuel Tank Assembly 6.5 Ltr Cart Part No Ap1.022.10.0.00 , Fuel Filter Cart Part No Ap1.022.13.0.00 , Fuel Cock Cart Part No Ap1.022.14.0.00 , Fuel Cock Cart Part No Ap1.022.14.0.Pr , Fuel Filter And Fuel Pipe Assembly Cart Part No Ap1.022.35.0.Pr , Choke Cable Assembly Cart Part No Ap1.023.65.0.00 , Lub Oil Drain Pipe Assembly Cart Part No Ap1.026.11.0.00 , Axle Cart Part No Ap1.101.14.0.00 , Circlip Cart Part No Ap1.101.17.0.00 , Wheel-160 Cart Part No Ap1.101.18.0.00 , Digital Display Unit (Voltage-Frequency-Cummulative Hours-Running Hours) Cart Part No Ap1.120.003.0.00 , Complete Engine Assembly With 2 6Kw Pm Alternator Cart Part No Ap1.7001.100.0.Pr , Wet Pm Kit (W/O Oil) For Ap1.2001 - Ccp196 Cart Part No Ap1.999.88.0.Sp , Cylinder Head Gasket Cart Part No Ap5.003.05.0.Pr , Cylinder Head Cover Gasket Cart Part No Ap5.003.07.0.Pr , Recoil Starter Assembly Cart Part No Ap5.007.20.0.Pr , Ignition Coil Assembly Cart Part No Ap5.010.10.0.Pr , Carburetor Assembly Cart Part No Ap5.014.20.0.00 , Carburetor Gasket Cart Part No Ap5.014.46.0.00 , Stepper Motor Assy Cart Part No Ap5.014.47.0.00 , Gasket For Muffler Cart Part No Ap5.016.11.0.Pr , Oil Safeguard Switch Cart Part No Ap5.017.07.0.Pr , Amf Panel Assembly For 20 To 25 Kva3phamfi Wall Mounting Cart Part No Apk.0253.10.0.00 , Amf Panel Assembly For 20 To 30 Kva1phamfi Wall Mounting Cart Part No Apk.0301.10.0.00 , 63 Amp 4 Pole Rear Mounting Chageover Switch Koel Cart Part No Apk.0400.006.0.Pr , Amf Panel Assembly For 45 Kva3phamfi Wall Mounting Cart Part No Apk.0453.10.0.00 , Con Rod Bearing: 6R1080 Std Cart Part No B.006.4.00.003 , Con Rod Bearing: 6R1080 0.25 Cart Part No B.006.4.00.013 , Bearing C R Kir 6R 10800 50 Cart Part No B.006.4.00.023 , Connecting Rod Bearing 030 Cart Part No B.006.4.00.033 , Connecting Rod Bearing 040 Cart Part No B.006.4.00.043 , Bearing C R Kir 4R Tastd Cart Part No B.006.4.30.003 , Bearing C Rkir Ra2 B 012 4 00 023 Cart Part No B.012.4.00.023 , Brg C/R Cart Part No B.019.3.00.003 , Brg C/R 010Kir Tv1 Cart Part No B.019.3.00.013 , Brg C R020kir Tv1 Cart Part No B.019.3.00.023 , Connecting Rod Bearing Cart Part No B.019.3.10.003 , Con Rod Bearing Ra3 Cart Part No B.038.4.00.003 , Con Rod Bearing Ra3 Cart Part No B.038.4.00.013 , Con Rod Bearing: Ra3 Cart Part No B.038.4.00.023 , Con Rod Bearing: Ra3 030 Cart Part No B.038.4.00.033 , Connecting Rod Bearing 010 Cart Part No B.040.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.040.4.00.023 , Con Rod Bearing: Sl90 Cart Part No B.055.4.00.003 , Connecting Rod Bearing 010 Cart Part No B.055.4.00.013 , Con Rod Bearing: Sl90 250Kva Cart Part No B.055.4.10.003 , Bearing C R Kir Sl90 250Kva0 25 Cart Part No B.055.4.10.013 , Bearing C R Kir Sl90 250Kva0 50 Cart Part No B.055.4.10.023 , Connecting Rod Bearing 030 U/S Cart Part No B.055.4.10.033 , Con Rod Bearing : Ha394 Cart Part No B.073.4.00.003 , Con Rod Bearing : Ha394 Cart Part No B.073.4.00.013 , Con Rod Bearing: Ha394 Cart Part No B.073.4.00.023 , Con Rod Bearing: Ha394 030 Cart Part No B.073.4.00.033 , Connecting Rod Bearing 040 Cart Part No B.073.4.00.043 , Con Rod Bearing :Ha394 Std Cart Part No B.073.4.10.003 , Con Rod Bearing: Ha394 0.25 Cart Part No B.073.4.10.013 , Con Rod Bearing: Ha394 020 U/S Nick Cart Part No B.073.4.10.023 , Con Rod Bearing: Ha394 030 U/S Nick Cart Part No B.073.4.10.033 , Con Rod Bearing: Ha 494 Cart Part No B.074.4.00.003 , Con Rod Bearing: Ha494 Cart Part No B.074.4.00.013 , Con Rod Bearing: Ha 494 Cart Part No B.074.4.00.023 , Con Rod Bearing: Ha494 Cart Part No B.074.4.00.033 , Con Rod Brg Ha494 Std Cart Part No B.074.4.10.003 , Con Rod Bearing Ha494 0.25 Cart Part No B.074.4.10.013 , Con Rod Bearing: Ha494 0.50 Cart Part No B.074.4.10.023 , Con Rod Bearing: Ha494 030 U/S Nick Cart Part No B.074.4.10.033 , Con Rod Bearing: Ha694 Cart Part No B.075.4.00.003 , Con Rod Bearing: Ha694 010 Cart Part No B.075.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.075.4.00.023 , Connecting Rod Bearing 030 Cart Part No B.075.4.00.033 , Con Rod Bearing: Ha694 Std Nick Cart Part No B.075.4.10.003 , Con Rod Bearing: Ha694 010 U/S Nick Cart Part No B.075.4.10.013 , Connecting Rod Bearing 020 U/S Cart Part No B.075.4.10.023 , Con Rod Bearing: Ha294 Cart Part No B.093.4.00.003 , Con Rod Bearing: Ha294 010 Cart Part No B.093.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.093.4.00.023 , Con Rod Bearing: Ha294 Std Nick Cart Part No B.093.4.10.003 , Con Rod Bearing: Ha294 010 U/S Nick Cart Part No B.093.4.10.013 , Con Rod Bearing: Dv10 Std Cart Part No B.547.4.00.003 , Kir 4R810 Ta B E Brg T4160030std Cart Part No B.552.0.10.003 , Bearing Big End: 4R810 Std Cart Part No B.552.4.00.003 , Con Rod Bearing: 4Rta Std Cart Part No B.584.4.00.003 , Connecting Rod Bearing 025 Cart Part No B.584.4.00.013 , Kir 4Rta C R Brg0 50 04692020 Cart Part No B.584.4.00.023 , Connecting Rod Bearing 075 Cart Part No B.584.4.00.033 , Kir 4Rta C/R Brg, 1.00, (04692020) Cart Part No B.584.4.00.043 , Con Rod Bearing: 6Tra Std Cart Part No B.584.4.10.003 , Con Rod Bearing: 6Rta 0.25 Cart Part No B.584.4.10.013 , Kir 6Rta C R Brg0 50 04692020 Cart Part No B.584.4.10.023 , Kir 6Rta C R Brg0 75 04692020 Cart Part No B.584.4.10.033 , Hollow Dowel Cart Part No B2.005.16.0.00 , Thrust Ring Half(G.E.-Top) Cart Part No B2.005.18.0.00 , Thrust Ring Half(G.E.-Bottom) Cart Part No B2.005.19.0.00 , Oil Safeguard Switch Cart Part No Bp1.001.02.0.Pr , Crankcase Assembly Cart Part No Bp1.001.10.0.00 , Oil Level Switch Assembly Cart Part No Bp1.001.20.0.00 , Crankcase Cover Gasket Cart Part No Bp1.002.02.0.00 , Intake Valve Guide Seal Cart Part No Bp1.003.02.0.00 , Cylinder Head Gasket Cart Part No Bp1.003.05.0.00 , Cylinder Head Assembly Cart Part No Bp1.003.10.0.00 , Cylinder Cover Gasket Cart Part No Bp1.003.13.0.00 , Spark Plug Cart Part No Bp1.003.17.0.00 , Spark Plug Cart Part No Bp1.003.18.0.00 , Cylinder Head Assembly Cart Part No Bp1.003.20.0.00 , Flywheel Assembly Cart Part No Bp1.004.10.0.Pr , Piston Assembly Cart Part No Bp1.005.10.0.00 , Piston Ring Set Cart Part No Bp1.005.20.0.00 , Con Rod Assly Cart Part No Bp1.005.30.0.00 , Crankshaft Assembly Cart Part No Bp1.005.40.0.00 , Starter Motor Cart Part No Bp1.006.10.0.00 , Pusher Cart Part No Bp1.007.09.0.00 , Intake Valve Cart Part No Bp1.007.15.0.00 , Exhaust Valve Cart Part No Bp1.007.16.0.00 , Valve Spring Cart Part No Bp1.007.18.0.00 , Valve Collet Cart Part No Bp1.007.24.0.00 , Filter Element Cart Part No Bp1.008.03.0.00 , Air Cleanergasket Cart Part No Bp1.008.08.0.Pr , Air Cleaner Assembly Cart Part No Bp1.008.10.0.00 , Carburetor Assembly Cart Part No Bp1.010.10.0.00 , Carburettor Connecting Block Cart Part No Bp1.010.22.0.00 , Carburettor Metal Gasket Cart Part No Bp1.010.23.0.00 , Carburettor Front Gasket Cart Part No Bp1.010.24.0.00 , Carburettor Metal Gasket Cart Part No Bp1.010.25.0.00 , Carburettor Connecting Block Gasket Cart Part No Bp1.010.26.0.00 , Muffler Cart Part No Bp1.011.01.0.Pr , Exhaust Gasket Cart Part No Bp1.011.08.0.00 , Catcon And Catcon Pipe Assembly Cart Part No Bp1.011.10.0.Spr , Recoil Starter Assembly Cart Part No Bp1.020.10.0.00 , Fuel Pipe Tank To Cock 160 Mm Cart Part No Bp1.022.02.0.00 , Fuel Pipe Cock To Filter 35 Mm Cart Part No Bp1.022.03.0.00 , Fuel Pipe Filter To Carburetor Cart Part No Bp1.022.04.0.00 , Fuel Pipe Clip Cart Part No Bp1.022.14.0.00 , Fuel Tank & Strainer Assly Cart Part No Bp1.022.30.0.00 , Mcb 13 Amp Cart Part No Bp1.023.41.0.00 , Speed Regulating Assembly Cart Part No Bp1.026.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No Bp1.026.11.0.00 , Spark Plug Cap Cart Part No Bp1.027.02.0.00 , Charge Coil Cart Part No Bp1.027.07.0.00 , Ignition Coil Assembly Cart Part No Bp1.027.10.0.00 , Charge Coil Assembly Cart Part No Bp1.027.20.0.00 , Wet Pm Kit (W/O Oil) For Bp1.3001 - Ccp302 Cart Part No Bp1.999.87.0.Sp , Bearing C Bush Kir Sl90 Cart Part No C.055.5.00.703 , C.073.6.00.003 Bearing C/Bush Kir Ha 394 Cart Part No C.073.6.00.003 , C.073.6.00.703 Bearing C/Bush Kir Ha 394 Cart Part No C.073.6.00.703 , Bearing Cam Bush Kir Dv10std Pf Cart Part No C.547.5.00.003 , Bearing C/Bush: Rb33 Std Pf Cart Part No C.597.6.00.003 , Cylinder Head Nut (Long) Cart Part No Cc1.001.003.0.00 , Cylinder Head Nut (Short) Cart Part No Cc1.001.004.0.00 , Rectangle Ring Gasket (4.1 X 4.25 X 2.3) Cart Part No Cc1.001.007.0.00 , Oil Seal: Rear 35X50x8 Cart Part No Cc1.001.011.0.00 , Oil Pressure Switch Cart Part No Cc1.001.012.0.00 , Oil Dipstickwith O Ring Cart Part No Cc1.001.018.0.00 , Sealing Plate Gasket Cart Part No Cc1.001.020.0.00 , Sealing Plate Cart Part No Cc1.001.021.0.00 , Thrust Piece And Locking Plate Cart Part No Cc1.001.022.0.00 , Needle Bearing 7941/15 Cart Part No Cc1.001.024.0.00 , Ball Bearing Cart Part No Cc1.001.025.0.00 , Crankcase Cover Gasket Cart Part No Cc1.001.026.0.00 , Bearing 6207 Cart Part No Cc1.001.027.0.00 , Oil Seal: Front 35X50x10 Cart Part No Cc1.001.033.0.00 , Drain Bolt Entension With Washer Cart Part No Cc1.001.036.0.00 , Start Switch Assembly Cart Part No Cc1.001.043.0.00 , Cylinder Head Stud (Long) M10x118 Cart Part No Cc1.001.052.0.00 , Cylinder Head Stud (Short) M10x105 Cart Part No Cc1.001.053.0.00 , Oil Drain Plug M16x15 With Gasket Cart Part No Cc1.001.054.0.00 , Cylinder Head Gasket 0.1 Cart Part No Cc1.001.061.0.00 , Cylinder Head Gasket 0.2 Cart Part No Cc1.001.062.0.00 , Cylinder Head Gasket 0.3 Cart Part No Cc1.001.063.0.00 , Cylinder Head Gasket 0.4 Cart Part No Cc1.001.064.0.00 , Cylinder Head Gasket 0.5 Cart Part No Cc1.001.065.0.00 , Cylinder Head Gasket 0.6Mm Cart Part No Cc1.001.067.0.00 , Cylinder Block Cart Part No Cc1.001.10.0.00 , Crankcase Cover Assembly Cart Part No Cc1.001.40.0.00 , Cylinder Head Assembly Cart Part No Cc1.001.50.0.00 , Gasket: Rocker Cover Cart Part No Cc1.002.008.0.00 , Rocker Arm Intake Cart Part No Cc1.002.009.0.00 , Adjusting Valve Spacer Cart Part No Cc1.002.011.0.00 , Valve Collet Cart Part No Cc1.002.012.0.00 , Valve Spring Seat Cart Part No Cc1.002.013.0.00 , Valve Spring Cart Part No Cc1.002.014.0.00 , Valve Guide Oil Seal Cart Part No Cc1.002.015.0.00 , Valve Spring Washer Cart Part No Cc1.002.016.0.00 , Intake Valve Cart Part No Cc1.002.021.0.00 , Exhaust Valve Cart Part No Cc1.002.022.0.00 , Rocker Cover Gasket Cart Part No Cc1.002.042.0.00 , Rocker Cover Assembly Cart Part No Cc1.002.10.0.00 , Rocker Arm Assembly Cart Part No Cc1.002.20.0.00 , Cylinder Head Assembly Cart Part No Cc1.002.30.0.00 , Bearing 6203 Cart Part No Cc1.003.007.0.00 , Nut: Flywheel Cart Part No Cc1.003.020.0.00 , Flywheel Gear Ring: Elect Starter Cart Part No Cc1.003.021.0.00 , Sleeve For Fuel Pump Cart Part No Cc1.003.022.0.00 , Push Rod Cart Part No Cc1.003.023.0.00 , Tappet Cart Part No Cc1.003.024.0.00 , Camshaft Cart Part No Cc1.003.026.0.00 , Con Rod Bearing Cart Part No Cc1.003.029.0.00 , Con Rod Assly Cart Part No Cc1.003.040.0.00 , Piston Assembly Cart Part No Cc1.003.10.0.00 , Balancing Shaft Assly Cart Part No Cc1.003.40.0.00 , Flywheelalternator Rotor Cart Part No Cc1.003.42.0.00 , Flywheelalternator Stator Coil Cart Part No Cc1.003.43.0.00 , Flywheelalternator Screw M6 Cart Part No Cc1.003.44.0.00 , Crankshaft And Gear Assly Cart Part No Cc1.003.50.0.00 , Flywheel Assembly Cart Part No Cc1.003.60.0.00 , Camshaft Assly Cart Part No Cc1.003.70.0.00 , Fuel Controller Cart Part No Cc1.004.023.0.00 , Oil Pump Driving Gear Assembly Cart Part No Cc1.004.10.0.00 , Fork Lever Assembly Cart Part No Cc1.004.20.0.00 , Speed Control Handle Assembly Cart Part No Cc1.004.30.0.00 , Lub Oil Pump Assembly Cart Part No Cc1.004.40.0.00 , Oil Filter Cart Part No Cc1.004.50.0.00 , Speed Control Handle Assembly Cart Part No Cc1.004.70.0.00 , Wind Leading Case Assembly Cart Part No Cc1.005.10.0.00 , Flange Bolt M8x1 25X25 8 8 Cart Part No Cc1.005.28.0.00 , Flange Bolt M8x1 25X15 8 8 Cart Part No Cc1.005.29.0.00 , Flange Bolt M8x1.25X20-8.8 Cart Part No Cc1.005.32.0.00 , Flange Bolt - M5x0.8X15 - 8.8 Cart Part No Cc1.005.37.0.00 , Air Cleaner Gasket Cart Part No Cc1.006.003.0.00 , Air Filter Element Cart Part No Cc1.006.008.0.00 , Extension Pipe Cart Part No Cc1.006.013.0.00 , Air Filter Hose Pipe Cart Part No Cc1.006.014.0.00 , Inlet Manifold Gasket Cart Part No Cc1.006.026.0.00 , Inlet Manifold Cart Part No Cc1.006.027.0.00 , Inlet Manifoldflame Heater Arrangement Cart Part No Cc1.006.035.0.Pr , Air Filter Hose Pipe Cart Part No Cc1.006.039.0.00 , Air Cleaner Assembly Cart Part No Cc1.006.110.0.00 , Air Inlet Manifold With Bush Cart Part No Cc1.006.28.0.Pr , Gasket Cart Part No Cc1.006.32.0.Pr , Gasket Cart Part No Cc1.006.36.0.Pr , Cold Starting Kit For Kcc Genset Minus 10 Degree Cart Part No Cc1.006.80.0.00 , Cold Starting Electrical Kit For Kcc Genset Minus 10 Degree Cart Part No Cc1.006.90.0.Pr , Fuel Filterwire Mesh Type Cart Part No Cc1.008.001.0.00 , Rotor Rear Fan Bush Cart Part No Cc1.009.25.0.Pr , Fuel Tank Cap Cart Part No Cc1.010.002.0.00 , Fuel Gauge Cart Part No Cc1.010.005.0.00 , Fuel Filter Cart Part No Cc1.010.007.0.00 , Flange Bolt M6x1x25 8.8 Cart Part No Cc1.010.008.0.00 , Hose Clip N16 Cart Part No Cc1.010.014.0.00 , Hose Clip Cart Part No Cc1.010.015.0.00 , Rubber Ring Gasket Cart Part No Cc1.010.016.0.00 , Rubber Window Cart Part No Cc1.010.017.0.00 , Fuel Pipe Id 7, Od 15, L 50 Mm Cart Part No Cc1.010.021.0.00 , Fuel Pipe Id 7, Od 15,L 130 Mm Cart Part No Cc1.010.022.0.00 , T-Joint Cart Part No Cc1.010.023.0.00 , Fuel Pipe Id 5, Od 10,L 175 Mm Cart Part No Cc1.010.031.0.00 , Fuel Pipe Id 7, Od 15, L 400 Mm Cart Part No Cc1.010.032.0.00 , Fuel Pipe From Filter To Engine Cart Part No Cc1.010.055.0.Pr , Fuel Pipe From Tank To Filter Cart Part No Cc1.010.056.0.Pr , Fuel Pipe From Filter To T Joint Cart Part No Cc1.010.057.0.Pr , Fuel Pipe From T Joint To Engine Cart Part No Cc1.010.058.0.Pr , Air Vent Pipe From T Joint To Fuel Tank Cart Part No Cc1.010.059.0.Pr , T Joint Cart Part No Cc1.010.060.0.Pr , Fuel Tank Sub Assembly With Cap Cart Part No Cc1.010.20.0.00 , Special Banjo Bolt Cart Part No Cc1.010.72.0.Pr , Fuel Tank With Strainer Cart Part No Cc1.010.80.0.00 , Rubber Ring Gasket Cart Part No Cc1.010.97.0.00 , Anti Vibration Mountpmount P 1B Whitep 503 Cart Part No Cc1.013.06.0.Pr , Fixed Wheel Assly Cart Part No Cc1.013.10.0.00 , Castor Wheel Assly Cart Part No Cc1.013.20.0.00 , Anti Vibration Mounts: Cchilii Cpcbii Cart Part No Cc1.013.40.0.00 , Tpr Fixed Wheel 100 Cart Part No Cc1.013.81.0.Pr , Tpr Swivel Wheel 100 Cart Part No Cc1.013.82.0.Pr , P-Mount Pd-1B (White) Cart Part No Cc1.013.83.0.Pr , Rubber 808A Blue Avm For Portable Cart Part No Cc1.013.87.0.Pr , Fip Adjusting Gasket: 0.5 Cart Part No Cc1.014.009.0.00 , Sealing Plate Gasket Cart Part No Cc1.014.011.0.00 , High Pressure Pipe Cart Part No Cc1.014.012.0.00 , Solenoid Base Cart Part No Cc1.014.014.0.00 , Solenoid Coil Cart Part No Cc1.014.016.0.00 , Fuel Injector Stud M6x1x50 Cart Part No Cc1.014.019.0.00 , Fuel Inj Pump Assly Cart Part No Cc1.014.021.0.00 , Fuel Inj Pump Assly Cart Part No Cc1.014.022.0.00 , Fuel Injectoradjusting Gasket Cart Part No Cc1.014.023.0.00 , Fuel Injection Pump Adjusting Gasket (0.1) Cart Part No Cc1.014.024.0.00 , Solenoid Assly Cart Part No Cc1.014.40.0.00 , Fuel Injection Pump Assembly Cart Part No Cc1.014.60.0.00 , Fuel Piping Assembly Cart Part No Cc1.015.10.0.00 , Catcon Box With Foam Cart Part No Cc1.016.012.0.00 , Catcon Box With Foam Cart Part No Cc1.016.013.0.00 , Engine Top Cowl Cart Part No Cc1.016.016.0.00 , Engine Bottom Cowl Cart Part No Cc1.016.017.0.00 , Key Type Lock: Small Cart Part No Cc1.016.034.0.00 , Snap Type Lock-Polymide Slide Latch Cart Part No Cc1.016.036.0.00 , Rubber Beading (Shock Pad) Cart Part No Cc1.018.001.0.00 , Cowling Assembly Cart Part No Cc1.018.20.0.00 , 32Amp Plug 2P + E Cart Part No Cc1.020.001.0.00 , Fuel Tank Cap For Kcc Portable Genset Cart Part No Cc1.020.96.0.00 , Fuel Level Sensor Hight132mm Cart Part No Cc1.022.03.0.Pr , Adaptor For Lop Sendor & Switch Cart Part No Cc1.032.03.0.00 , Electric Fuel Pump Cart Part No Cc1.073.03.0.Pr , Head Gasket 0 1 Mm Cart Part No Cc1.099.006.0.00 , Head Gasket 0 2 Mm Cart Part No Cc1.099.007.0.00 , Charging Magneto Cart Part No Cc1.099.011.0.00 , Inlet Gasket Air Filter Cart Part No Cc1.099.013.0.00 , Push Rod Cart Part No Cc1.099.019.0.00 , Inlet Valve Assly Cart Part No Cc1.099.021.0.00 , Exhaust Valve Cart Part No Cc1.099.022.0.00 , Subassembly Of Cc418 Diesel Engine Cart Part No Cc1.1013.10.0.00 , Flame Heater Cart Part No Cc1.108.01.0.Pr , 0-300 Vac Analogue Voltmeter Cart Part No Cc1.120.002.0.00 , 32Amp Socket: 2P+E Cart Part No Cc1.120.05.0.00 , Hour Meter 230V Ac: Cchili Cart Part No Cc1.120.09.0.00 , Mcb: 17.5A 1 Pole Power On/Off Cart Part No Cc1.120.29.0.00 , 6A 12V Dc Battery Charger Cart Part No Cc1.120.33.0.Pr , Battery Charger : 5A 12 Vdc Cart Part No Cc1.120.48.0.00 , Load On Lamp Cart Part No Cc1.120.52.0.00 , 5 Pin Male Connector Cart Part No Cc1.120.56.0.00 , 5 Pin Female Connector Cart Part No Cc1.120.57.0.00 , Key Lock Switch 3A Cart Part No Cc1.120.61.0.00 , Avr Cchilli Alterernator 5Kva Cart Part No Cc1.121.004.0.00 , 5Kva Alternator Rotor Cart Part No Cc1.121.11.0.00 , Alternator Rear Frame For Chhota Chilli Cart Part No Cc1.121.15.0.00 , Alternator Fan: Chota Chili Cart Part No Cc1.121.17.0.00 , Bearing 6204 Cart Part No Cc1.121.29.0.00 , Rotor Set Bolt M10x1.25X260 Cart Part No Cc1.121.38.0.00 , Alternator Front Frame Cart Part No Cc1.121.42.0.00 , 5Kva Alternator Carbon Bush Cart Part No Cc1.121.44.0.00 , Rotor Rear Fan Cart Part No Cc1.121.53.0.00 , Avrmodel Av 132 S Cart Part No Cc1.121.64.0.Pr , Avrmodel Ds Cart Part No Cc1.121.67.0.Pr , Fan Bush Assy Cart Part No Cc1.121.73.0.Pr , 16 Amp Socket 2P + E Cart Part No Cc1.122.05.0.00 , 16 Amp Plug Cart Part No Cc1.122.06.0.00 , 6A/10A Toggle Switch For Dc Supply On/ Off Cart Part No Cc1.130.05.0.00 , 5Kva Kcc Amf Panel Assembly Cart Part No Cc1.130.30.0.00 , 5.5 Kva Kcc Amf Panel Assembly Cart Part No Cc1.140.50.0.Pr , 12V2a Battery Charger With Input Output Leads Cart Part No Cc1.150.53.0.Pr , Gasket Muffler Engine Side Cart Part No Cc1.151.023.0.00 , Exhaust System For Cc 418 Engine Cart Part No Cc1.151.06.0.Spr , Catalytic Converter (Catcon) Cart Part No Cc1.151.101.0.Pr , Muffler Assy Cart Part No Cc1.151.103.0.Pr , Exhaust Silencer For Chotta Chilli Cart Part No Cc1.151.11.0.Pr , Exhaust Gasket Cart Part No Cc1.151.13.0.00 , Exhaust Gasketengine Side Cart Part No Cc1.151.16.0.00 , Expansion Bellow Cart Part No Cc1.151.21.0.00 , Exhaust Gasket Cart Part No Cc1.151.23.0.00 , Exhaust Silencerupperfor Chotta Chilli Cart Part No Cc1.151.66.0.Pr , Lower Silencer Assly Cart Part No Cc1.151.75.0.Pr , Upper Silencer Assly Cart Part No Cc1.151.76.0.Pr , Gasketgraphite Cart Part No Cc1.151.99.0.Pr , 5Kva Brushless Alternator S F Cc418 Engine Cart Part No Cc1.153.03.0.Pr , Alternator Assly Cart Part No Cc1.153.10.0.00 , Alternator For Rotor Assembly For Chhota Chilli Cart Part No Cc1.153.20.0.00 , 5Kva Alternator Stator Assembly Cart Part No Cc1.153.30.0.00 , Rectifier +(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.33.0.00 , Rectifier -(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.34.0.00 , Mov(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.36.0.00 , Connector Plate Assembly Cart Part No Cc1.153.40.0.00 , Alternator Assembly Cart Part No Cc1.156.20.0.00 , Engine Wiring Harness For Chhota Chilli Cart Part No Cc1.160.30.0.00 , Engine Wiring Harness For Chhota Chilli Cart Part No Cc1.160.80.0.Pr , Control Cable For Amf Ats Panel Kcc Cart Part No Cc1.170.20.0.00 , Canopy For 5Kva Chhota Chilli Diesel Fabrication Parts With Foam Locks Cart Part No Cc1.175.10.8.00 , 5 Kva Diesel Std Front Door Assly Cart Part No Cc1.175.32.0.00 , 5 Kva Diesel Std Noise Damper Assly Cart Part No Cc1.175.35.0.00 , 5 Kva Diesel Std Rh Panel Assy Cart Part No Cc1.175.36.0.00 , 5Kva Diesel Std Lh Panel Assly. Cart Part No Cc1.175.38.0.00 , Pm Alternator Module 6Kw Cart Part No Cc1.175.57.0.Pr , Dc Regulator With Bat Reverse Protection Cart Part No Cc1.175.63.0.Pr , Fuel Tank With Strainer Cart Part No Cc1.175.88.0.Pr , Fuel Hose Pipe From Filter To T Joint & Tank To Filter (Id- 7Mm Od-14Mm,L-55Mm) Cart Part No Cc1.175.93.0.Pr , Fuel Hose Pipe 3 Air Vent Pipe From T Joint To Fuel Tank (Id- 5Mm Od-13Mm,L-180Mm) Cart Part No Cc1.175.96.0.Pr , Fuel Hose Pipe 4 From T Joint To Engine (Id- 7Mm Od-14Mm,L-310) Cart Part No Cc1.175.97.0.Pr , Fuel Hose Pipe 5 (Id- 5Mm Od-13Mm,L-770Mm) Cart Part No Cc1.175.99.0.Pr , Battery Cable Assy For 5Kva Chhota Chilli Genset Cart Part No Cc1.180.20.0.Pr , Injector Copper Washer 8X15 (0.1Mm) Cart Part No Cc1.190.013.0.00 , Injector Copper Washer 8X15 (0.2Mm) Cart Part No Cc1.190.014.0.00 , Injector Copper Washer 8X15 (0.3Mm) Cart Part No Cc1.190.015.0.00 , Injector Copper Washer 8X15 (0.4Mm) Cart Part No Cc1.190.016.0.00 , Injector Copper Washer 8X15 (1 Mm) Cart Part No Cc1.190.017.0.00 , Injector Copper Washer 8X15 (1.5 Mm) Cart Part No Cc1.190.018.0.00 , Injector Copper Washer 8X15 (2 Mm) Cart Part No Cc1.190.019.0.00 , Injector Copper Washer 8X15 (3 Mm) Cart Part No Cc1.190.021.0.00 , Injector Cart Part No Cc1.190.06.0.00 , Fuel Overflow Connection For Injector Cart Part No Cc1.190.25.0.00 , Fuel Injector Assembly Cart Part No Cc1.190.30.0.00 , Piston Assembly Cart Part No Cc1.191.12.0.Pr , Piston Ring Set Cart Part No Cc1.191.30.0.00 , Starter 12V Cart Part No Cc1.193.01.0.00 , Pm Alternator Stator Cart Part No Cc1.193.012.0.00 , Pm Alternator Rotor Gear Ring Cart Part No Cc1.193.014.0.00 , Pm Alternator Rotor Cart Part No Cc1.193.015.0.00 , Pm Alternator Rotor Fan Cart Part No Cc1.193.018.0.00 , Adaptor: Chota Chilli Cart Part No Cc1.193.02.0.00 , Pm Alternator Assembly Cart Part No Cc1.193.40.0.00 , Recoil Starter Assembly Cart Part No Cc1.196.10.0.00 , Flange Bolt M6x1x30 Cart Part No Cc1.300.01.0.00 , Gas Spring 600N Cart Part No Cc1.300.24.0.00 , Spark Arrestor Cart Part No Cc1.405.01.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.1051 - Cc418 Cart Part No Cc1.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.3008... - Cc306 G1 Cart Part No Cc1.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 5Kva_Cc1.4007 - Cc418 G1.1 Cart Part No Cc1.999.17.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.4001.96 ,Cc1.4004.96, Cc1.4004- Chhota Chilli5kva Portabl Cart Part No Cc1.999.55.0.Sp , Rear Oil Seal Cart Part No Cc3.001.006.0.00 , Ball Bearing Cart Part No Cc3.001.010.0.00 , Cylinder Head Stud (Short) Cart Part No Cc3.001.011.0.00 , Rectangle Ring Gasket 4.5X2.2 Cart Part No Cc3.001.017.0.00 , Crankcasecover Gasket Cart Part No Cc3.001.025.0.00 , Ball Bearing Cart Part No Cc3.001.026.0.00 , Front Oil Seal Cart Part No Cc3.001.032.0.00 , Cylinder Head Gasket0.5 Mm Cart Part No Cc3.001.76.0.00 , Intake Valve Cart Part No Cc3.002.003.0.00 , Exhaust Valve Cart Part No Cc3.002.004.0.00 , Rocker Arm Cart Part No Cc3.002.017.0.00 , Adjusting Valve Spacer Cart Part No Cc3.002.018.0.00 , Valve Collet Cart Part No Cc3.002.019.0.00 , Valve Spring Seat Cart Part No Cc3.002.020.0.00 , Valve Guide Oil Seal Cart Part No Cc3.002.022.0.00 , Rocker Arm Assembly Cart Part No Cc3.002.20.0.00 , Cylinder Head Assembly Cart Part No Cc3.002.30.0.00 , Rockercover Gasket Cart Part No Cc3.003.001.0.00 , Con Rod Assly Cart Part No Cc3.003.040.0.00 , Lub Oil Pump Assembly Cart Part No Cc3.004.10.0.00 , Oil Pump Driving Gear Assembly Cart Part No Cc3.004.20.0.00 , Fork Lever Assembly Cart Part No Cc3.004.30.0.00 , Connecting Rod Bearing Cart Part No Cc3.005.009.0.00 , Piston Assembly Cart Part No Cc3.005.10.0.00 , Piston Ring Set Cart Part No Cc3.005.30.0.00 , Ball Bearing Cart Part No Cc3.006.009.0.00 , Flywheel Gear Ring Cart Part No Cc3.006.011.0.00 , Balancing Shaft Assly Cart Part No Cc3.006.10.0.00 , Inlet Manifold Gasket Cart Part No Cc3.006.21.0.00 , Push Rod Cart Part No Cc3.007.001.0.00 , Tappet Cart Part No Cc3.007.002.0.00 , Cam Shaft & Gear Assembly Cart Part No Cc3.007.10.0.00 , Crankshaft And Gear Assly Cart Part No Cc3.007.20.0.00 , Air Filter Hose Pipe Cart Part No Cc3.008.001.0.00 , Air Cleaner Gasket Cart Part No Cc3.008.004.0.00 , Air Filter Element Cart Part No Cc3.008.008.0.00 , Extension Pipe Cart Part No Cc3.008.015.0.00 , Oil Seal Cart Part No Cc3.012.014.0.00 , Fuel Controller Cart Part No Cc3.012.015.0.00 , Anti Vibration Mountpmount P 1A Bluep 503 Cart Part No Cc3.013.08.0.Pr , Recoil Starter Assmbly Cart Part No Cc3.015.20.0.00 , Engine Speed Control Assembly Cart Part No Cc3.017.20.0.00 , Crankcase Cover Gasket Cart Part No Cp1.002.02.0.00 , Crankcase Cover Assembly Cart Part No Cp1.002.10.0.00 , Cylinder Head Gasket Cart Part No Cp1.003.05.0.00 , Cylinder Head Assembly Cart Part No Cp1.003.10.0.00 , Cylinder Cover Gasket Cart Part No Cp1.003.13.0.00 , Flywheel Assembly Cart Part No Cp1.004.10.0.00 , Piston Assly Cart Part No Cp1.005.10.0.00 , Piston Ring Set: Std Cart Part No Cp1.005.20.0.00 , Connecting Rod Assy Cart Part No Cp1.005.30.0.00 , Crankshaft Assembly Cart Part No Cp1.005.40.0.00 , Starter Motor Cart Part No Cp1.006.10.0.00 , Pusher Cart Part No Cp1.007.09.0.00 , Intake Valve Cart Part No Cp1.007.15.0.00 , Exhaust Valve Cart Part No Cp1.007.16.0.00 , Rocker Arm Assembly Cart Part No Cp1.007.20.0.00 , Carburetor Assembly Cart Part No Cp1.010.10.0.00 , Carburettor Rear Gasket Cart Part No Cp1.010.23.0.00 , Carburettor Front Gasket Cart Part No Cp1.010.24.0.00 , Carburettor Metal Gasket Cart Part No Cp1.010.25.0.00 , Catcon And Catcon Pipe Assembly Cart Part No Cp1.011.20.0.Spr , Anti Vibration Mount (708A Mix 03 Blue40 4 To 5 Alternetor Side ) Cart Part No Cp1.012.01.0.Pr , Recoil Starter Assembly Cart Part No Cp1.020.10.0.00 , Ignition Coil Assembly Cart Part No Cp1.027.10.0.00 , Complete Engine Assembly Ccp389 Cart Part No Cp1.1001.100.0.00 , Small End Bush-Dm10. Cart Part No D1.005.03.0.00 , Joint Ring: Liner Dm10 Cart Part No D1.008.02.0.00 , Crankshaft Assly: Dm10 Cart Part No D1.011.40.0.00 , Fuel Pump Cart Part No D1.019.10.0.00 , Con.Rod Assly-Dm10(70 Mm Pin ) Cart Part No D1.035.10.0.00 , Fuel Pump Bracket Cart Part No D1.131.01.0.00 , Fuel Pump Tappet Plunger:Ew10 Cart Part No D1.131.02.0.00 , F.P.Rocker Lever Cart Part No D1.131.03.0.00 , Roller Cart Part No D1.131.04.0.00 , Roller Pin Cart Part No D1.131.05.0.00 , Assembly Of Fpr Lever - Ew10 Cart Part No D1.131.10.0.00 , Joint: Rocker Cover Cart Part No D1.133.09.0.00 , Piston Assembly Cart Part No D1.134.20.0.00 , Piston Ring Set - Ew10,3 Rv Cart Part No D1.134.30.0.00 , Piston Ring Set-Ea10 102.12 Cart Part No D1.134.40.0.00 , Piston Assembly: Ea10 With Ring Set 102.12 Cart Part No D1.134.50.0.00 , Gasket: Cylinder Head Ew10 Cart Part No D1.135.02.0.00 , Valve Guide(Semi-Finish) - Ew10 Cart Part No D1.135.03.9.00 , Cylinder Head Gasketnamew10 Cart Part No D1.135.18.0.00 , Valve Push Rod Cart Part No D1.138.01.0.00 , Air Inlet Manifold Cart Part No D1.139.01.0.00 , Joint: Air Inlet Mfold-Ew10 Cart Part No D1.139.03.0.00 , Gasket: Exhaust Ew10 Cart Part No D1.140.03.0.00 , Fulcrum Bracket Assly: Ew10 Cart Part No D1.148.20.0.00 , Fulcrum Bracket Assemblywith Indicator E Series Acwr Engines Cart Part No D1.148.30.0.00 , Cyl Liner Assembly-Ew10 Cart Part No D1.311.10.0.00 , Anti Vibration Mounts Cart Part No D1.314.01.0.00 , Anti Vibration Mounts Cart Part No D1.314.02.0.00 , Bush For Avm Locking S F 90 Crs Avms Cart Part No D1.316.05.0.00 , Set Of Joints Cart Part No D1.317.40.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No D1.326.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No D1.326.02.0.00 , Gear Pump Assembly With Relief Valve Cart Part No D1.328.10.0.00 , Mb Hsg + Brg Assembly Ge - Ew10 Cart Part No D1.329.10.0.00 , Wet Pm Kit (W/O Oil) For D1.4805.91 - Ew10 Cart Part No D1.999.04.0.Sp , M Bcap Side Boltm12x1 75X145 L Cart Part No D16.001.09.0.00 , M Bcap Side Boltm12x1 75X165 L Cart Part No D16.001.11.0.00 , M Bcap Side Boltm12x1 75X188 L Cart Part No D16.001.12.0.00 , Joint For Core Window120 Crs6 Holes Cart Part No D16.001.31.0.Pr , Joint For Core Window100 Crs6 Holes Cart Part No D16.001.32.0.Pr , Ferrul Tube For Push Rod Cart Part No D16.001.36.0.Pr , Nozzle Body Cart Part No D16.001.39.0.Pr , Sealing Ring (For Push Rod) Cart Part No D16.001.48.0.00 , Spacerfor Hp Pipe Cart Part No D16.001.56.0.Pr , Oil Spray Nozzle Cart Part No D16.001.58.0.Pr , Balance Weight For All Webs Cart Part No D16.003.03.0.Pr , Adaptor For Crank Pulley Cart Part No D16.003.06.0.00 , Crankshaft Gear115 Length Cart Part No D16.003.14.0.Pr , Crank Pulley (Pcd 232) Poly V 12Pk Cart Part No D16.003.15.0.Pr , Crank Shaft Assly Cart Part No D16.003.20.0.Pr , Thrust Plate For Cam Shaft Cart Part No D16.004.03.0.00 , Camgear Speed Ring Cart Part No D16.004.04.0.00 , Thrust Plate For Cam Shaftwidth 17 9 Cart Part No D16.004.05.0.Pr , Thrust Plate For Cam Shaftwidth 18 7 Cart Part No D16.004.11.0.00 , Thrust Platefor Cam Shaftwidth 17 5 Cart Part No D16.004.13.0.00 , Thrust Plate Cart Part No D16.004.15.0.00 , Thrust Plate Width 18 2 Cart Part No D16.004.16.0.00 , Cam Gearfinish Cart Part No D16.004.17.0.Pr , Pistonfor 1250Kva Cart Part No D16.006.07.0.Pr , Cylinder Head Assembly Complete Cart Part No D16.007.150.0.Pr , Double Gear Support Cart Part No D16.011.11.0.Pr , Joint (For Oil Seal Housing) Cart Part No D16.012.02.0.00 , Pumping Geardriving Cart Part No D16.013.03.0.00 , Pumping Geardriven Cart Part No D16.013.04.0.00 , Oil Pump Housing Shim 0 2 Thick Cart Part No D16.013.16.0.Pr , Lub Oil Pump Sub Assly 100Mm Wide Cart Part No D16.013.30.0.Pr , Lub Oil Cooler Header (L.H.) Cart Part No D16.014.01.0.Pr , Lub Oil Cooler Header (R.H.) Cart Part No D16.014.02.0.Pr , Fuelpipe(Fuelpumptomainfilter)(Lhfromge) Cart Part No D16.014.05.0.00 , Oil Filter Adaptor Cart Part No D16.014.09.0.Pr , Lub Oil Cooler Headear Assly(Rhs) Cart Part No D16.014.10.0.Pr , Oil Cooler Cart Part No D16.014.12.0.Pr , Relief Valve Body Cart Part No D16.014.13.0.00 , Joint For Lub Oil Headerrh Cart Part No D16.014.15.0.Pr , Threaded Plug For Relief Valve Body Cart Part No D16.014.16.0.Pr , Header Mounting Boltm10x1 5X135l Cart Part No D16.014.17.0.Pr , Adaptor (Male M22x1.5 & Female M10x1) Cart Part No D16.014.18.0.Pr , Lub Oil Cooler Headear Assly(Lhs) Cart Part No D16.014.20.0.Pr , O Ring (For Relief Valve Body ) Cart Part No D16.014.21.0.Pr , Jointfor Oil Filter Adaptor Cart Part No D16.014.22.0.Pr , Lub Oil Cooler Header & Oil Filter Adaptor Assembly Lh Cart Part No D16.014.40.0.Pr , O Ring For W.P. Housing Cart Part No D16.016.03.0.00 , Jointbetween Water Pump Thermostat Cover Cart Part No D16.016.04.0.Pr , Water Pump Assembly Cart Part No D16.016.100.0.Pr , Water Pump Pulleypcd 115 Poly V 12 Pk Cart Part No D16.016.15.0.Pr , Suction Tubewith Flanged Ends R H Cart Part No D16.016.16.0.00 , Suction Tubewith Flanged Ends Cart Part No D16.016.17.0.Pr , 12 Pk Poly V Belt 2630 Epdm Cart Part No D16.016.22.0.Pr , Jointforplate W P Housing Rh Cart Part No D16.016.26.0.Pr , Jointforplate Water Pump Housing Lh Cart Part No D16.016.29.0.Pr , V Belt For 1800Rpm Cart Part No D16.016.37.0.Pr , Dipstick Assemblyfor 1250Kva Cart Part No D16.017.130.0.Pr , Lub Oil Sumpfabricated Cart Part No D16.017.14.0.Pr , Adaptor For Dipstick Cart Part No D16.017.17.0.00 , Joint ( For Oil Filling Body) Cart Part No D16.017.18.0.00 , Dipstick Assemblydipstick With Adaptor Cart Part No D16.017.50.0.Pr , Bracket For Fuel Filter Cart Part No D16.020.02.0.00 , Hp Pipe Assembly (Rail To Cylinder No. 1 & 5) Cart Part No D16.021.110.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 2 & 6) Cart Part No D16.021.120.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 3 & 7) Cart Part No D16.021.130.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 4 & 8) Cart Part No D16.021.140.0.Pr , Hp Pipe Assemblyrail To Cylinder No9 13 Cart Part No D16.021.150.0.00 , Hp Pipe Assemblyrail To Cylinder No9 13 Cart Part No D16.021.150.0.Pr , Hp Pipe Assemblyrail To Cylinder No10 14 Cart Part No D16.021.160.0.Pr , Hp Pipe Assemblyrail To Cylinder No11 15 Cart Part No D16.021.170.0.00 , Hp Pipe Assemblyrail To Cylinder No11 15 Cart Part No D16.021.170.0.Pr , Hp Pipe Assemblyrail To Cylinder No12 16 Cart Part No D16.021.180.0.Pr , Hp Pipe Assembly (Rail Connection) Cart Part No D16.021.190.0.Pr , Hp Pipe Assemblypump To Rail Lhs Cart Part No D16.021.210.0.Pr , Hp Pipe Assembly (Pump To Rail Rhs) Cart Part No D16.021.220.0.Pr , Hp Pipe Assembly(Routed Rail To Cyl. 4) Cart Part No D16.021.230.0.Pr , Hp Piperail To Cylinder No1 16 Cart Part No D16.021.34.0.Pr , Hp Piperail To Cylinder No2 15 Cart Part No D16.021.36.0.Pr , Hp Piperail To Cylinder No3 14 Cart Part No D16.021.37.0.Pr , Hp Piperail To Cylinder No4 13 Cart Part No D16.021.38.0.Pr , Hp Pipe (Rail To Cylinder No. 5 & 12) Cart Part No D16.021.39.0.00 , Hp Pipe (Rail To Cylinder No. 6 & 11) Cart Part No D16.021.41.0.00 , Hp Pipe (Rail To Cylinder No. 8 & 9) Cart Part No D16.021.42.0.00 , Hp Piperail To Cylinder No7 10 Cart Part No D16.021.43.0.Pr , Hp Pipepump To Rail Lhs Cart Part No D16.021.44.0.Pr , Hp Pipepump To Rail Rhs Cart Part No D16.021.46.0.Pr , Hp Pipe (Balancing Pipe) Cart Part No D16.021.47.0.00 , Rail Connection Cart Part No D16.021.48.0.00 , Clamp For Hp Pipe (Pump To Rail) (Mntg. On Rail Clamp) Cart Part No D16.021.49.0.00 , Hp Pipefip To Rail Rh Side Cart Part No D16.021.55.0.Pr , Hp Pipefip To Rail Lh Side Cart Part No D16.021.56.0.Pr , Bracketfor Rail Mtglhs Cart Part No D16.021.63.0.Pr , Bracketfor Rail Mtgrhs Cart Part No D16.021.64.0.Pr , Bracketfor Hp Pipe Cart Part No D16.021.66.0.Pr , Rail Assembly 1Pulley End Cart Part No D16.021.91.0.Pr , Rail Assembly 2Flywheel End Cart Part No D16.021.92.0.Pr , Bracket For Hp Pipe Cart Part No D16.021.93.0.Pr , Fuel Pipe (Fuel Pump To Main Filter) (Lh From Ge) Cart Part No D16.022.102.0.00 , Fuel Pipefuel Pump To Main Filter Rh From Ge Cart Part No D16.022.103.0.Pr , Head Leak Off Pipe Assembly Cart Part No D16.022.107.0.Pr , Fuel Pipe(Pre Filter To Main Filter Common) Cart Part No D16.022.112.0.00 , Deairazation Pipe Cart Part No D16.022.114.0.00 , Adaptorm16 X M14 Cart Part No D16.022.12.0.Pr , Fuel Pipepump Leak Off L Hfrom G E Cart Part No D16.022.139.0.Pr , Fuel Pipe (Pump Leak Off Pipe R.H. From Ge) Cart Part No D16.022.141.0.00 , Fuel Pipe (Main Filter To Pump R.H. Side) Cart Part No D16.022.142.0.Pr , Fuel Pipe (Main Filter To Pump L.H. Side) Cart Part No D16.022.143.0.00 , Fuel Piperail Leackoff Pipe Assembly Cart Part No D16.022.147.0.Pr , Fuel Pipe Cart Part No D16.022.149.0.Pr , Fuel Pipe Cart Part No D16.022.153.0.Pr , Fuel Piperhs From Ge Cart Part No D16.022.156.0.Pr , Fuel Pipe Cart Part No D16.022.167.0.Pr , Fuel Pipe Cart Part No D16.022.168.0.Pr , Fuel Pipe Cart Part No D16.022.169.0.Pr , Fuel Pipe Cart Part No D16.022.171.0.Pr , Fuel Pipe Cart Part No D16.022.172.0.Pr , Fuel Pipe ( Pre Filter To Main Filter Common ) Cart Part No D16.022.178.0.Pr , Inlet Manifold L H Gear End Cart Part No D16.023.01.0.Pr , Inlet Manifold R H Gear End Cart Part No D16.023.03.0.00 , Sleeve For Inlet Manifolddia 94 Cart Part No D16.023.13.0.Pr , Joint For Cover Plate Cart Part No D16.023.15.0.00 , Banjo Bolt Cart Part No D16.023.18.0.Pr , O Ringfor Inlet Manifold Adaptor Sleeve Dia 104 Cart Part No D16.023.28.0.Pr , O Ringfor Inlet Manifold Sleeve Dia 94 Cart Part No D16.023.29.0.Pr , Joint Bet. Inlet Manifold & Cyl Head Cart Part No D16.023.31.0.00 , O Ring Cart Part No D16.023.35.0.00 , Adaptor For Inlet Manifold2 Port Cart Part No D16.023.39.0.Pr , Sleeve For Inlet Manifolddia 117 Cart Part No D16.023.43.0.00 , O Ring For Inlet Manifold Adaptor Sleeve (Dia 117) Cart Part No D16.023.44.0.00 , Joint For Inlet Manifold Cart Part No D16.023.46.0.Pr , Joint (For Inlet Manifold R.H.) Cart Part No D16.023.48.0.00 , Joint (For Inlet Manifold L.H.) Cart Part No D16.023.49.0.00 , Inlet Manifoldrh From Pe Cart Part No D16.023.52.0.Pr , Inlet Manifold Lh From Pe Cart Part No D16.023.54.0.00 , Adaptor Cart Part No D16.023.59.0.Pr , Adaptor Cart Part No D16.023.61.0.Pr , Gasket Cart Part No D16.023.62.0.Pr , Stud M10x1 5 Cart Part No D16.023.64.0.Pr , Bracket Cart Part No D16.023.65.0.Pr , Banjo Bolt Cart Part No D16.023.66.0.00 , Exhaust Manifold Cart Part No D16.024.12.0.00 , Exhaust Manifold (Rh, Lh 2 Port) Cart Part No D16.024.13.0.00 , Exhaust Manifold (2 Port) Cart Part No D16.024.14.0.00 , Bracket Turbo Adaptor Rhs From Fwe Cart Part No D16.024.32.0.Pr , Bracket For Turbo Adaptor Lhs From Fwe Cart Part No D16.024.33.0.Pr , Expansion Bellow 3 Mm Cart Part No D16.024.35.0.00 , Exhaust Manifold (Adaptor Side M10) Cart Part No D16.024.37.0.00 , Bracket For Turbo Adaptor4 Bolts Cart Part No D16.024.42.0.Pr , Bracket For Turbo Adaptor3 Bolts Cart Part No D16.024.43.0.Pr , Turbo Adaptorlh From Ge Cart Part No D16.024.44.0.Pr , Turbo Adaptorrh From Ge Cart Part No D16.024.45.0.Pr , Bracket 1L Hfrom Fwe Cart Part No D16.024.46.0.Pr , Bracket 2L Hfrom Fwe Cart Part No D16.024.47.0.Pr , Bracket 3R Hfrom Fwe Cart Part No D16.024.48.0.Pr , Bracket 4R Hfrom Fwe Cart Part No D16.024.49.0.Pr , Expansion Bellow (For Exh. Manifold) Cart Part No D16.024.51.0.Pr , Joint For Flywheel Housing Cart Part No D16.025.02.0.00 , Joint For Gear Casing Cart Part No D16.025.04.0.00 , Cover Plate Cart Part No D16.025.11.0.00 , O Ring (For Cover Plate) Cart Part No D16.025.12.0.00 , Gear Casing Cart Part No D16.025.21.0.Pr , Deflectorfor Flywheel End Cart Part No D16.025.24.0.Pr , Mud Slingerfor Flywheel End Cart Part No D16.025.25.0.Pr , Starter Ring Cart Part No D16.026.07.0.00 , Bolt For Flywheel200 Mmlength Cart Part No D16.026.09.0.Pr , Sensor Ring Cart Part No D16.026.13.0.Pr , Flywheel Assy With Toothed Sensor Ring Cart Part No D16.026.30.0.Pr , 24V 9Kw Starter L H Sfrom Flywheel End Sideprestolite Ms7 304K Cart Part No D16.027.14.0.Pr , Deep Groove Ball Bearing ( 35 X 62 X 14 )6007-2Rs1 Cart Part No D16.029.03.0.00 , Spacer Bet. Extension Pulley & Crank Pulley Cart Part No D16.029.09.0.00 , Bracket Cart Part No D16.029.12.0.Pr , Pulley For Fan Drive250 P C D Cart Part No D16.029.34.0.Pr , Fan Drive Sub Assembly Cart Part No D16.029.50.0.Pr , Damper Cart Part No D16.030.01.0.Pr , Pipe Thermostat To Radiator In Cart Part No D16.031.07.0.Pr , D16 031 17 0 Pr Clamping Bracket For Thermostat Pipe Cart Part No D16.031.17.0.Pr , Dv2 031 18 0 Pr Clamp Cart Part No D16.031.18.0.Pr , Cooling Fan For Radiator (62 , 11 Blades) Cart Part No D16.031.35.0.Pr , Radiator For Dv16 Genset Cart Part No D16.031.60.0.Pr , Recovery Bottel Bracket Lh Cart Part No D16.031.61.0.Pr , Turbocharger For Dv16 Enginehe600fga112n68tc B97q89qc26ab Cart Part No D16.032.26.0.00 , V Band For Turbine Out Exhaust Bendd16 Ctt Turbochargerid 127 Mm Cart Part No D16.032.32.0.Pr , Turbo Oil Inlet Pipe (Lh From Pe) Cart Part No D16.032.36.0.00 , Turbo Oil Inlet Piperh From Pe Cart Part No D16.032.37.0.00 , Turbo Oil Drain Pipe (Lh From Pe) Cart Part No D16.032.38.0.00 , Joint For Turbocharger Cart Part No D16.032.43.0.Pr , Jointfor Flange For T C Lub Oil Outlet Pipe Cart Part No D16.032.44.0.00 , Jointfor Flange For T C Lub Oil Outlet Pipe Cart Part No D16.032.44.0.Pr , Turbocharger Asslyr Hfrom Pe Cart Part No D16.032.45.0.00 , Turbo Lub Oil Inlet Pipelhs Cart Part No D16.032.51.0.Pr , Turbo Oil Drain Pipelhs From Fwe Cart Part No D16.032.52.0.Pr , Turbo Lub Oil Inlet Piperhs Cart Part No D16.032.53.0.Pr , Turbo Oil Drain Piperhs From Fwe Cart Part No D16.032.54.0.Pr , 439619022074 Turbocharger For Dv16 Engine_Rhs Cart Part No D16.032.58.0.Pr , 439619022073 Turbocharger For Dv16 Engine_Lhs Cart Part No D16.032.59.0.Pr , Exhaust Elbowlhs From Ge Cart Part No D16.032.62.0.Pr , Exhaust Elbowrhs From Ge Cart Part No D16.032.63.0.Pr , Spacer13x30 Cart Part No D16.032.65.0.Pr , Cac Yoke Pipe Cart Part No D16.033.13.0.00 , Cac Pipe 1 Straight Pipe Cart Part No D16.033.14.0.00 , Cac Pipe 2 Straight Pipe To Radiator In Pipe Cart Part No D16.033.15.0.Pr , Sleeve For Cac Pipe Dia 114 Cart Part No D16.033.17.0.Pr , Sleeve For Cac Pipe Dia 84) Cart Part No D16.033.18.0.Pr , Top Bracket For Cac Pipe Cart Part No D16.033.22.0.Pr , Rubber Sleeve Cart Part No D16.033.24.0.00 , Joint Cart Part No D16.033.28.0.00 , Joint Cart Part No D16.033.28.0.Pr , T Bolt V Band Clamps (108 Dia). Cart Part No D16.033.34.0.00 , O Ring For Cac Pipe Sleeve114 Dia Cart Part No D16.033.35.0.Pr , O Ringfor Cac Pipe Sleeve Dia 84 Cart Part No D16.033.36.0.Pr , Compressor Out Pipe O Ringdv16 Ctt Turbocharger Cart Part No D16.033.37.0.Pr , Compressor Out Pipedv16 Ctt Turbocharger Rhs From Pe Cart Part No D16.033.38.0.00 , Compressor Out Pipedv16 Ctt Turbocharger Lhs From Pe Cart Part No D16.033.39.0.Pr , V Band For Compressor Out Piped16 Ctt Turbochargerid 100 Mm Cart Part No D16.033.41.0.Pr , Cac Out Pipe 1(Radiator To Inlet Manifold) Cart Part No D16.033.44.0.00 , Cac Out Pipe 2(Radiator To Inlet Manifold) Cart Part No D16.033.46.0.00 , Hose For Cac Pipeid 138 X Id 144 Cart Part No D16.033.47.0.Pr , Hose For Cac Out Pipeid 138 Both Sides Cart Part No D16.033.48.0.Pr , Joint For Cac Out Pipe Cart Part No D16.033.49.0.00 , Bracket For Cac Out Pipe Cart Part No D16.033.51.0.Pr , Cac Adaptor Bracket R H Cart Part No D16.033.53.0.00 , Cac Adaptor Bracket L H Cart Part No D16.033.54.0.00 , T Bolt Clampfor Dia 141 149 Cart Part No D16.033.55.0.Pr , Cac Pipe In ( From T/C To Radiator In) Cart Part No D16.033.56.0.Pr , O Ring Cart Part No D16.033.74.0.Pr , Compressor Out Pipe Cart Part No D16.033.75.0.Pr , Compressor Out Pipe Cart Part No D16.033.76.0.Pr , Mtg Foot Cart Part No D16.034.03.0.Pr , O Ring For Ladder In Cart Part No D16.036.07.0.00 , O Ringfor Ladder Oil Hole Cart Part No D16.036.08.0.Pr , Special Bolt For Ladderm14x2x175l Cart Part No D16.036.09.0.00 , O Ring For Ladder (Water Out) Cart Part No D16.036.14.0.00 , Sleevebetween Ladder And Crankcase Cart Part No D16.036.15.0.Pr , Spacer R H Between Cooler Header Ladder For 1250Kva Cart Part No D16.036.23.0.Pr , Spacer L H Between Cooler Header Ladder For 1250Kva Cart Part No D16.036.24.0.Pr , Lub Oil Coolerfor 1250Kva Cart Part No D16.036.38.0.Pr , Adaptorfor Centrifuge Pipe Cart Part No D16.041.02.0.00 , Centrifuge Oil In Pipe Cart Part No D16.041.10.0.00 , Delivary Adaptor Cart Part No D16.042.03.0.Pr , Joint Betdelivary Adaptor Ladder Cart Part No D16.042.04.0.Pr , Delivery Adaptor Cart Part No D16.042.05.0.00 , Clamp For Delivery Tube Cart Part No D16.042.06.0.00 , Clamp For Delivery Tube Cart Part No D16.042.07.0.00 , Sub Assembly Of Delivary Tubecenter Cart Part No D16.042.30.0.Pr , Suction Adaptor Cart Part No D16.043.01.0.Pr , Joint For Suction Cart Part No D16.043.02.0.Pr , Stainer Basket Cart Part No D16.043.04.0.Pr , Alternator Mtgbracket Cart Part No D16.044.01.0.Pr , Ccv Adaptor Cart Part No D16.046.01.0.00 , Ccv Mounting Bracket Cart Part No D16.046.09.0.00 , Ccv Hose Pipe In Cart Part No D16.046.13.0.Pr , Ccv Drain Pipe (Rh From Ge) Cart Part No D16.046.16.0.00 , Ccv Drain Pipe (Lh From Ge) Cart Part No D16.046.17.0.00 , Ccv Out Pipe Cart Part No D16.046.18.0.00 , Clamp For Ccv Drain Pipe Cart Part No D16.046.19.0.00 , Bracket For Ccv Cart Part No D16.046.21.0.00 , Ccv Out Elbow Cart Part No D16.046.22.0.Pr , Ccv Hose Pipe(Breather Hose To Air Cleaner Pipe) Cart Part No D16.046.23.0.00 , Ccv Connector (I. D. 20) Cart Part No D16.046.24.0.Pr , Joint Between Bell Housing & Adaptor Cart Part No D16.046.25.0.00 , Ccv Hose Pipe 2Breather Hose To Air Cleaner Pipe Cart Part No D16.046.26.0.Pr , Ccv Hose Pipe In 1 Cart Part No D16.046.27.0.Pr , Ccv Hose Pipe 2 Cart Part No D16.046.28.0.Pr , Breather Housing Cart Part No D16.046.34.0.Pr , Deflector Plate Cart Part No D16.046.35.0.Pr , Mounting Plate Cart Part No D16.046.36.0.Pr , Breather Platewith Holes Cart Part No D16.046.37.0.Pr , Brether Plate Cart Part No D16.046.39.0.Pr , Breather Mesh Plate For Brether Housing Cart Part No D16.046.41.0.Pr , Spacer For Heat Shield Cart Part No D16.051.07.0.00 , Heat Shield For Turbo Adaptorrhs Cart Part No D16.051.23.0.Pr , Heat Shield For Turbo Adaptorlhs Cart Part No D16.051.24.0.Pr , Idler Bracket Lh Cart Part No D16.052.01.0.Pr , Idler Pulley Cart Part No D16.052.02.0.00 , Idler Bracket Rh Cart Part No D16.052.07.0.Pr , Eye Bolt Cart Part No D16.052.09.0.00 , Idler Bracket With Pulleyasslyrh Cart Part No D16.052.10.0.Pr , Spacer 15X28 Cart Part No D16.052.12.0.00 , Pivot For Ideler Bracket Cart Part No D16.052.14.0.Pr , Shaft For Ideler Pulley Cart Part No D16.052.15.0.00 , Lever For Belt Tensioning Cart Part No D16.052.16.0.Pr , Idler Bracket With Pulleyasslylh Cart Part No D16.052.20.0.Pr , Ideler Mtgboltm12x1 75X185l Cart Part No D16.052.21.0.00 , Ideler Bracket Mtgbolt Cart Part No D16.052.22.0.00 , Bearing6007 2Rs1 C3gjn Cart Part No D16.052.23.0.Pr , Brass Set Screwm12 X 1 75 X 50 Cart Part No D16.052.31.0.Pr , Brass Nutm12 X 1 75 Cart Part No D16.052.32.0.Pr , Brass Washerm12 Cart Part No D16.052.33.0.Pr , Fuel Level Sensor Height 220 Mm With High Low Pressure Switch Cart Part No D16.057.06.0.Pr , Anti Vibration Mounts For D16 Cart Part No D16.061.06.0.Pr , Alternator Pulley Cart Part No D16.062.05.0.Pr , Bracket For Alternator Pulley Cart Part No D16.062.06.0.Pr , Expansion Bellow Cart Part No D16.064.04.0.Pr , Joint Between Diffuser And Bellow Cart Part No D16.064.05.0.Pr , Joint Between Silencer And Extension Pipe Cart Part No D16.064.09.0.Pr , Rain Cap Assembly For Tail Pipe Cart Part No D16.064.11.0.Pr , Exhaust Bend Cart Part No D16.064.13.0.Pr , Hose Between Thermostat Radiator In Cart Part No D16.064.14.0.Pr , Hose Cart Part No D16.064.18.0.Pr , Hose For Thermostat To He Out Pipe Cart Part No D16.064.19.0.Pr , Hose For Raw Water In Cart Part No D16.064.21.0.Pr , Spacer Plate Cart Part No D16.064.32.0.Pr , Silencer Assembly Cart Part No D16.064.50.0.Pr , Exhaust Pipe Flange Spacer Cart Part No D16.064.61.0.Pr , Exhaustbellow Cart Part No D16.064.62.0.Pr , Common Rail Fuel Pump Assly Cart Part No D16.072.60.0.00 , Wiring Box Assembly R H S From Pulley End Side Cart Part No D16.099.10.0.Pr , Wiring Box Assembly R H S From Pulley End Side Cart Part No D16.099.20.0.Pr , Engine Wiring Harness Box L Hfrom Pulley End Cart Part No D16.099.30.0.Pr , Wiring Harness Box Assembly Lhs From Pully End Side Cart Part No D16.099.50.0.Pr , Hose Cart Part No D16.505.14.0.Pr , Air Cleaner Support Cart Part No D16.505.18.0.Pr , Air Cleaner Support Cart Part No D16.505.19.0.Pr , Air Cleaner Support Cart Part No D16.505.21.0.Pr , Air Cleaner Mounting Top Support Cart Part No D16.505.26.0.Pr , Stay Rod For Air Cleaner Support Cart Part No D16.505.27.0.Pr , Stay Rod For Air Cleaner Support Cart Part No D16.505.28.0.Pr , Radiator Drain Pipe Cart Part No D16.505.33.0.Pr , Ecu Mounting Support Channel 1 Cart Part No D16.505.34.0.Pr , Air Filter Primary Cart Part No D16.505.41.0.00 , Air Filter Safety Cart Part No D16.505.42.0.00 , Hose Clamp -T Bolt For Air Cleaner 1010 Kva Cart Part No D16.505.46.0.00 , D16.505.47.0.Pr-Hose Clamp, T Bolt Dia.138.1 Cart Part No D16.505.47.0.Pr , Hose Elbow Cart Part No D16.505.48.0.Pr , Hose Cart Part No D16.505.52.0.00 , Support Bracket For Fuel Piping Cart Part No D16.505.53.0.Pr , Air Cleaner Hoseturbo To Air Cleaner Cart Part No D16.505.63.0.Pr , Air Cleaner Pipe From Hosel H Side Cart Part No D16.505.75.0.Pr , Air Cleaner Pipe From Hoser H Side Cart Part No D16.505.76.0.Pr , Air Cleaner Assembly (R.H) Side-18 Mettalic Cart Part No D16.505.80.0.00 , Air Cleaner Assembly (L.H) Side-18 Mettalic Cart Part No D16.505.90.0.00 , Air Cleaner Assembly For 1010 Kva Cart Part No D16.506.10.0.00 , Pre-Filter Cartridge Cart Part No D16.507.03.0.00 , Adaptor Cart Part No D16.507.07.0.Pr , Fuel Pre-Filter Cart Part No D16.507.10.0.00 , Fuel Pipefuel Tank To Leak Off Pipe Cart Part No D16.507.11.0.Pr , Fuel Pipefuel Tank To Leak Off Pipe Cart Part No D16.507.12.0.Pr , Fuel Pipe From Tank To External Fuel Tank Cart Part No D16.507.13.0.Pr , Adaptorm22x1 5 Both Side Cart Part No D16.507.14.0.Pr , Hose Cart Part No D16.507.33.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No D16.507.43.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No D16.507.44.0.Pr , Fuel Return Pipem16x1 5 Male Plug And M22x1 5 Union Nut Cart Part No D16.507.47.0.Pr , Koel Alternator, 1010Kva, 415Vac, 3 Phase, 50 Hz, 1500 Rpm, 40 Deg Cart Part No D16.701.20.0.Pr , Coolant Level Switchlow High Level With Led Cart Part No D16.812.17.0.Pr , Rh Lock For Canopy Door750 Kva And Above Cart Part No D16.850.111.0.Pr , Lh Lock For Canopy Door750 Kva And Above Cart Part No D16.850.112.0.Pr , Door Handle Suitable For Dv Cart Part No D16.850.51.0.Pr , Rmsremote Monitoring Systemunit S F Crdi With 2 Years Data Package Inclusive Cart Part No D16.858.11.0.Pr , Assembly For Krm Unit For Kg1500 With Pakage S F Crdi Cart Part No D16.858.12.0.Pr , Lbend Clip 25 Dia For Flexible Pipe Cart Part No D16.902.33.0.Pr , Battery Charger 15Amp 24V Cart Part No D16.902.34.0.Pr , Bracket For Relay Mounting Cart Part No D16.902.36.0.Pr , Bolt For 1010Kva Relay Mounting Bracket Cart Part No D16.902.37.0.Pr , Red Terminal Block Cart Part No D16.902.44.0.Pr , Black Terminal Block Cart Part No D16.902.45.0.Pr , Set Bolt For Flywheel Cart Part No D16.902.56.0.Pr , Earthing Cable Alternator To Base Plate 50X6mm1600mm Length Cart Part No D16.903.01.0.Pr , Earthing Cable For Radiator Cart Part No D16.903.04.0.Pr , 2 Channel, 3 Change Over, 24V, 10A Relay Board Cart Part No D16.903.13.0.00 , Battery Cables 95 Sqmm 650Mm Length Cart Part No D16.903.30.0.Pr , Control Panel Mouting Bracket Cart Part No D16.903.38.0.Pr , Canopy Wiring Harness Sf Dv 2X1010kva Optiprime Project Containerized Cart Part No D16.905.80.0.Pr , Nfc Link For D350 Avr Cart Part No D16.906.05.0.00 , Engine Wiring Harness Sf Control Panel To Interface Box Cart Part No D16.906.20.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection Cart Part No D16.906.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection Cart Part No D16.906.60.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection With Stana Cart Part No D16.906.70.0.Pr , Control Panel Assembly For Dv16 3Phase 1010Kva Crdi Silent Genset Cart Part No D16.908.30.0.Pr , Syncronization Panel With 1010Kva Crdi Genset Cart Part No D16.908.40.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No D16.909.20.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No D16.909.30.0.Pr , Wiring Harness From Master Ecu To Sensor Cart Part No D16.909.40.0.Pr , Control Panel To Dg2 Engine Wiring Harness Cart Part No D16.910.50.0.Pr , Control Panel To Dg1 Avr Harness Cart Part No D16.910.90.0.Pr , Control Panel To Dg2 Avr Harness Cart Part No D16.911.20.0.Pr , Control Panel To Incomer Breaker 1 Interface Harness Cart Part No D16.912.30.0.Pr , Control Panel To Incomer Breaker 2 Interface Harness Cart Part No D16.912.40.0.Pr , Power Cable Wiring For 2X1010kva Optiprime Genset Cart Part No D16.912.50.0.Pr , Dg1 Ct Wiring Harness For 2X1010kva Optiprime Genset Cart Part No D16.912.60.0.Pr , Dg2 Ct Wiring Harness For 2X1010kva Optiprime Genset Cart Part No D16.912.80.0.Pr , Kvaser Cable For Ecu_Crdi Set Cart Part No D16.999.05.0.Sp , Tool Kit For Software Programming Cart Part No D16.999.06.0.Sp , Wet Pm Kit (W/O Oil ) For D16.1024 Cart Part No D16.999.10.0.Sp , Crankshaft Complete- Dm20 Cart Part No D2.003.40.0.00 , L.O.Pipe(Crcase To Both Rsh) Cart Part No D2.008.10.0.00 , Joint: Suction Tube Cart Part No D2.009.06.0.00 , Suction Tube Assemblydm20 Cart Part No D2.009.10.0.00 , Alternator: 12V 35A Cart Part No D2.059.01.0.00 , Gear Pump: Dm20/Da20 Rr Cart Part No D2.141.40.0.00 , Flywheel Housing Cart Part No D2.147.01.0.00 , Flywheel Assly,Es,Sr - S/F Sae-2 Hsg. Cart Part No D2.148.10.0.00 , Flywheel Assly,Es,Sr - S/F Sae-3 Hsg. Cart Part No D2.149.10.0.00 , Flywheel Assembly Cart Part No D2.156.10.0.00 , Anti Vibration Mtg: Genset Cart Part No D2.163.01.0.00 , V Belt: Ax55 Cogged Cart Part No D2.164.02.0.00 , Core Plug 1 4 Bsp12 5 Length Cart Part No D2.301.02.0.00 , Joint: Cyl Head & Rbox Cart Part No D2.307.03.0.00 , Set Of Joints Cart Part No D2.323.40.0.00 , Leak Off Pipe: Injector To Bottom Fuel Tank Cart Part No D2.338.10.0.00 , Cyl Head Steel Gasket:Daf10 Cart Part No D3.003.06.0.00 , Push Rod Tube Assembly Cart Part No D3.005.20.0.00 , Le Top Bearing(With Hole) Cart Part No D3.030.02.0.00 , Small End Bush With Hole Cart Part No D3.030.03.0.00 , Connecting Rod Assly: Oil Hole Cart Part No D3.030.10.0.00 , Blower Asly.Rr-Da10 Cart Part No D3.032.10.0.00 , Crank Pulley (Finish)(Bolted Type)(175.4 Pcd) Cart Part No D3.036.03.0.00 , Wet Pm Kit (W/O Oil) For D3.1609.92 Cart Part No D3.160.9.0.Sp , Starter 12V Cart Part No D3.176.01.0.00 , Ignition Switch Cart Part No D3.213.08.0.00 , 25Amp Sp Mcb Cart Part No D3.213.17.0.00 , Mcb17 5Amp1 Pole Cart Part No D3.214.11.0.Pr , Koel Green Alternatorkg5 S T Framel Kg 40 C0sae 3 11 5 415V50 Hz0 8 Pf Cart Part No D3.229.24.0.Pr , Engine Monitoring System Unit Type - Ems926 - Volt. - 8 - 32V Dc Cart Part No D3.242.04.0.00 , Power Cablefor Ea10 5Kva 1Ph Emerald Cart Part No D3.242.22.0.Pr , Rra Condenser Diode & Varistor Cart Part No D3.247.01.0.Asp , Terminal Block Assembly- 5-10 Kva 1 Phase Cart Part No D3.247.02.0.Asp , De Brkt- Prot. Screen Asly-5/10Kva-1 Phase Cart Part No D3.247.05.0.Asp , Space Heater 54W, 230 V. Kva Rating:- (5 To 160 Kva) Cart Part No D3.247.12.0.Asp , Dsrl (Digital Simplified Regulator) For Frame Kg3,Kg28 Cart Part No D3.247.15.0.Asp , Koel Green Alternatorkg5 S S Framel Kg 40 C1sae 3 11 5 230V50 Hz0 8 Pf Cart Part No D3.247.25.0.Pr , Koel Green Alternator, Kg 7 S S, Frame Ls- Kg40 C2, Sae3 11.5, 230V, 50 Hz, 0.8 Pf (Ag3 Cart Part No D3.247.27.0.00 , Engine Wiring Harness Assembly: Ea10 Engine Suitable For Kg934 Control Unit Cart Part No D3.256.10.0.00 , Engine Wiring Harness Sf 5 & 7 Kva Ea10 Engine Cart Part No D3.256.40.0.00 , Engine Wiring Harness For Ea10 Emerald Cart Part No D3.256.50.0.Pr , Cylinder Head Stud (Long) Cart Part No D3.301.05.0.00 , Stud For Rocker Support Cart Part No D3.317.03.0.00 , Cylinder Head Assembly Cart Part No D3.317.20.0.00 , Valve Pair Cart Part No D3.317.99.0.00 , Shim: Liner To Cr Case 0.005Th Cart Part No D3.318.02.0.00 , Shim: Liner To Cr Case 0.010Th Cart Part No D3.318.03.0.00 , Shim: Liner To Cr Case 0.015Th Cart Part No D3.318.04.0.00 , Rocker Support Assly: Ea10 Cart Part No D3.319.30.0.00 , Button For Yoke Cart Part No D3.321.03.0.00 , Cowling Set Cart Part No D3.324.10.0.00 , Leak Off Connector Cart Part No D3.325.01.0.00 , Leak Off Pipe Assly: Crcase To Fwe Mb Hsg & Ext Rocker Support Cart Part No D3.326.10.0.00 , Set Of Joints Cart Part No D3.329.40.0.00 , Handle For Door Cart Part No D3.331.09.0.00 , Hinge For Door(Stainless Steel,Clinched Bolt) Cart Part No D3.331.18.0.00 , Cylinder Liner- Ea10 Cart Part No D3.335.01.0.00 , Hose For Air Cleaner Cart Part No D3.336.01.0.00 , Exh.Silencer S/F Single & Twin Cyl.Air-Cooled Ve Canopy Cart Part No D3.343.28.0.00 , Tail Pipe For Silencer Cart Part No D3.343.29.0.00 , Air Intake Adaptor Cart Part No D3.343.33.0.00 , Exhaust Bend(Lagged) - For Ea10,Ea20,Ew20,Ew24 & Ew28 Engines Cart Part No D3.343.34.0.00 , Inlet Pipe(Erw) Cart Part No D3.343.36.0.00 , Hose Air Intake Adaptor To Air Cleaner Cart Part No D3.343.37.0.00 , Exhaust Bendupward Opening Cart Part No D3.344.01.0.00 , Exhaust Silencer Cart Part No D3.344.02.0.00 , Silencer Assembly Cart Part No D3.344.35.0.Pr , Exhaust Manifold Cart Part No D3.345.03.0.00 , Joint Silencer Exh Pipe To Tail Pipe Cart Part No D3.345.05.0.00 , Tower Bolt, 4.0 Long(Brass) Cart Part No D3.345.07.0.00 , Blower Assemblyfor Ea 10 Cpcb Ii Cart Part No D3.351.10.0.Pr , Injector Assly Cart Part No D3.353.10.0.00 , Liner Piston Set: Ea10 3Rv Cart Part No D3.399.01.0.00 , Wet Pm Kit (W/O Oil) For D3.9616 - Daf10 Cart Part No D3.961.06.0.Sp , Wet Pm Kit (W/O Oil) For D3.1605.92 - Ea10 Cart Part No D3.999.12.0.Sp , Wet Pm Kit (W/O Oil) For D3.1610, D3.1630, D3.4866 - Ea10 Cart Part No D3.999.13.0.Sp , Wet Pm Kit (W/O Oil) For D3.4807, D3.5803, D3.9801,D3.9804 - Ea10 Cart Part No D3.999.14.0.Sp , Wet Pm Kit (W/O Oil ) For D3.1101 Cart Part No D3.999.25.0.Sp , Wet Pm Kit (W/O Oil) For D3.1609.92 D3.9615 D3.1605. D3.9616...92..- Ea10 G1 Cart Part No D3.999.42.0.Sp , Wet Pm Kit (W/O Oil) For D3.8301, D3.8323, D3.98324, D3.9618, D3.8322, D3.8324- Ea10g1 Cart Part No D3.999.50.0.Sp , Joint: Adaptor Inlet Mfold Cart Part No D4.007.06.0.00 , Blower Assembly Cart Part No D4.014.10.0.00 , Bracket For Fan Body Cart Part No D4.023.01.0.00 , Cooling Blower Assembly With Bracket Da20 Acwr Engine Cart Part No D4.023.30.0.00 , Spacer For Alternator Bracket Cart Part No D4.026.01.0.00 , Fuel Gauge Cart Part No D4.117.01.0.00 , Fuel Level Gauge Cart Part No D4.117.06.0.00 , Feed Pump Cart Part No D4.119.02.0.00 , Eccentric Cart Part No D4.119.05.0.00 , Joint: Feed Pump Cart Part No D4.119.09.0.00 , Gear Cover S/F Feed Pump - Vave Cart Part No D4.119.12.0.00 , Flywheel Housing Cart Part No D4.121.01.0.00 , Expansion Bellow: 285 Mm Cart Part No D4.122.01.0.00 , Expansion Bellow: 232Mm Double Flange Cart Part No D4.122.02.0.00 , Steel Joint: Exp Bellow Double Flange Cart Part No D4.122.03.0.00 , Crankshaft Gear Wheel Cart Part No D4.135.01.0.00 , Primary Air Cleaner Element Cart Part No D4.149.15.0.00 , Wet Pm Kit (W/O Oil) For D4.1610.91,D4.9615,D4.9801,D4.9803 Cart Part No D4.1610.91.0.Sp , Hose: Air Inlet Manifold Cart Part No D4.171.04.0.00 , Cam Shaft & Gear Assembly Cart Part No D4.302.30.0.00 , Camshaft Assly- Ea16-Ea20 Rr Cart Part No D4.302.40.0.00 , Wet Pm Kit (W/O Oil) For D4.5801,D8.8301,D8.8309.Pb,D8.9301,D8.9303 Cart Part No D4.580.1.0.Sp , Wet Pm Kit (W/O Oil) For D4.4804 - Ea20 Cart Part No D4.999.06.0.Sp , Wet Pm Kit (W/O Oil) For D4.1610.92 Cart Part No D4.999.08.0.Sp , Wet Pm Kit (W/O Oil) For D4.1616.92..D4.1615...- Ea20.2.Air Cart Part No D4.999.43.0.Sp , Piston Pin Cart Part No D5.006.02.0.00 , Bracket For Stop Solenoid Cart Part No D5.114.02.0.00 , Cylinder Head Gasket Ew8 5 Cart Part No D5.302.02.0.00 , Valve Guide(Semi-Finish) - Ew8.5 Cart Part No D5.302.03.9.00 , Ring Set Std: Ew8.5 3Rv Cart Part No D5.303.10.0.00 , Piston Assembly: Ew8.5 Cart Part No D5.303.20.0.00 , Joint: Air Inlet Mfold Cart Part No D5.304.02.0.00 , Gasket: Exhaust Mfold Ew8.5 Cart Part No D5.305.02.0.00 , Cylinder Liner Cart Part No D7.002.01.0.00 , Cyl Head Steel Gasket:Daf8 Cart Part No D7.003.06.0.00 , Push Rod Tube Assembly Cart Part No D7.005.10.0.00 , Valve Pair Cart Part No D7.302.99.0.00 , Rocker Cover Cart Part No D7.304.01.0.00 , Breather Cart Part No D7.304.03.0.00 , Joint: Rocker Cover Eaf8 7Ea10 Cart Part No D7.304.04.0.00 , Flange For Nozzle Cart Part No D7.305.01.0.00 , Rocker Support Sub Assly: Eaf8 Cart Part No D7.306.40.0.00 , Assly Camshaft Sr Stl A2 1500 Eaf8 Ea10 Cart Part No D7.309.30.0.00 , Cylinder Head Stud (Short) Cart Part No D7.310.01.0.00 , Inlet Valve Assly Cart Part No D7.311.01.0.00 , Inlet Valve Seat Insert (Cpcb) Cart Part No D7.311.02.0.00 , Inlet Valve Seat Insert(Semi-Finish) - Eaf8 Cart Part No D7.311.02.9.00 , Exhaust Valve(Finish) - Eaf8 Cart Part No D7.312.01.0.00 , Exhaust Valve Seat Insert(Semi-Finish) - Eaf8 Cart Part No D7.312.02.9.00 , H.P. Pipe Assly G.E.Side:Eaf8/Ea10 Cart Part No D7.313.10.0.00 , Cyl.Liner,Optimised Fins(Std)(Finish) - Eaf8 Cart Part No D7.317.01.0.00 , Wet Pm Kit (W/O Oil) For D3.8304 - Ea10 Cart Part No D7.999.03.0.Sp , Temp. Switch - 230 Deg. C Cart Part No D8.066.01.0.00 , Exh Fan: 450Mm With Connector Cart Part No D8.079.26.0.00 , Tube Light 12V Dc,6 Long For Canopy With Connector Cart Part No D8.079.48.0.00 , Tube Light 24V Dc,6 Long For Canopy With Connector Cart Part No D8.079.49.0.00 , Led Tube Light12vdc2w6long With 2 Pin Connector Cart Part No D8.079.52.0.Pr , Koel Green Alternator, Kg 10 S S Frame: L Kg 40 E, Sae-2 11.5, 230V, 50 Hz, 0.8 Pf Cart Part No D8.105.19.0.00 , Koel Green Alternatorkg 10 S T Framel Kg 40 C2sae 2 11 5 415V50 Hz0 8 Pf Cart Part No D8.106.19.0.Pr , Fip: Ea16 Cpcb-Ii Cart Part No D8.111.01.0.00 , Koel Green Alternator, Kg 12.5 S S Frame: L Kg 423 B, Sae-2 11.5, 230V, 50 Hz, 0.8 Pf Cart Part No D8.117.23.0.00 , Relay Card - 2.5 Channel - 12V Dc Cart Part No D8.138.18.0.00 , Wet Pm Kit (W/O Oil) For D8.1605.91,D8.4812.91,D8.4813.91,D8.5801,D8.5802,D8.9804,D8.9804.0 Cart Part No D8.1605.91.0.Sp , Wet Pm Kit (W/O Oil) For D8.1612.92 Cart Part No D8.1612.92.0.Sp , Starter12vstmrvh 1104 Cart Part No D8.176.01.0.Pr , Control Panel Schematic For 12 5Kva3ph With Kg640 Ip A Cart Part No D8.190.70.0.Pr , Control Panel Schematic For 12 5Kva1ph With Kg640 Ip A Cart Part No D8.190.80.0.Pr , Terminal Barag3080650000 Rating10 251 Phframekg164 J Kg 184 A B D E Cart Part No D8.191.02.0.00 , Engine Wiring Harness Assembly Cart Part No D8.256.10.0.00 , Engine Wiring Harness Assembly Cart Part No D8.256.30.0.00 , Engine Wiring Harness For Ea16 Emerald Cart Part No D8.256.70.0.Pr , Engine Wiring Harness For Ea16 Cart Part No D8.256.80.0.Pr , Power Harness For Ea16 3Ph Engine Emrald Cart Part No D8.258.40.0.Pr , Power Harness For Ea16 1Ph Engine Emrald Cart Part No D8.258.50.0.Pr , Crankcase Assembly Cart Part No D8.301.10.0.00 , Air Inlet Manifoldfinishaluminumea16 Cart Part No D8.303.11.0.00 , Cowling Set Cart Part No D8.305.20.0.00 , Special Banjo Bolt -M6 Cart Part No D8.306.02.0.00 , Lube Oil Pipe Assly: Crcase To Rocker Support Cart Part No D8.306.10.0.00 , Exhaust Manifold (Lagged) (Upward Opening) Cart Part No D8.307.05.0.00 , Special Socket Head Set Screw 5 16Bsf X 1 Copper Coated Cart Part No D8.307.06.0.00 , Fuel Pipe Feed Pump To Filter Cart Part No D8.308.07.0.00 , Fuel Pipe Nozzle To Tank Cart Part No D8.308.08.0.00 , Fuel Pipe Tank To Feed Pump Cart Part No D8.308.09.0.00 , Nozzle Leak Off Pipe Assembly - Ea16 Cart Part No D8.308.20.0.00 , Set Of Joints Cart Part No D8.312.40.0.00 , Fuel Pump Bracket Cart Part No D8.316.01.0.00 , Air Cleaner Element Cart Part No D8.319.03.0.00 , Hose For Cleaner Cart Part No D8.319.05.0.00 , Air Cleaner Assly: Dry Type Cart Part No D8.319.10.0.00 , Fuel Pipe (Feed Pump To Spinon Filter) Cart Part No D8.334.01.0.00 , Fuel Pipe (Spinon Filter To Fuel Pump) Cart Part No D8.334.02.0.00 , Blower Assembly With Bracket (Ea16 Cpcb Ii) Cart Part No D8.372.40.0.Pr , Liner Piston Set: Ea16 3Rv Cart Part No D8.399.01.0.00 , High Pressure Pipe Assembly Cart Part No D8.712.10.0.00 , V Belt Ax56 Cog Cart Part No D8.714.03.0.00 , Cylinder Head Assly Complete For Ea16 Cpcb Ii Engine Cart Part No D8.715.20.0.Pr , Wet Pm Kit (W/O Oil) For D8.8324 Cart Part No D8.832.4.0.Sp , Wet Pm Kit (W/O Oil ) For D8.9801 Cart Part No D8.999.10.0.Sp , Piston Pin Chetak Cart Part No D9.006.02.0.00 , Koel Green Alternatorkg 7 5 S S Framel Kg 40 C2sae 2 11 5 230V50 Hz0 8 Pf Cart Part No D9.061.14.0.Pr , Koel Green Alternatorkg 7 5 S T Framel Kg 40 C1sae 2 11 5 415V50 Hz0 8 Pf Cart Part No D9.062.18.0.Pr , Gasket: Cylinder Head Ew12 Cart Part No D9.302.02.0.00 , Ring Set Std: Ew12 3Rv Cart Part No D9.303.10.0.00 , Piston Assembly: Ew14 Cart Part No D9.303.20.0.00 , Cyl Liner Assembly-Ew14 Cart Part No D9.311.10.0.00 , Set Of Joints Cart Part No D9.312.40.0.00 , Valve Pair Cart Part No D9.322.99.0.00 , Wet Pm Kit (W/O Oil) For D9.4806.91, D9.4807.91 - Ew14 Cart Part No D9.999.08.0.Sp , Wet Pm Kit (W/O Oil) For D1.4810.91, D9.1606, D9.5801, D9.4810.91, D1.4809.91, D9.4811.91 - E Cart Part No D9.999.10.0.Sp , Wet Pm Kit (W/O Oil) For D9.1615 Cart Part No D9.999.11.0.Sp , Leak Off Pipe Assly Cart Part No Dc.004.10.0.00 , Radiator Assly With Shroud Dm26 Cart Part No Dc.033.10.0.00 , Adaptor Plate For Lube Oil Filter Cart Part No Dc.034.02.0.00 , Joint: Bween Adaptor & Crcase Cart Part No Dc.034.04.0.00 , Hose: Radiator Btm Tank To Thermostat Pipe Cart Part No Dc.123.01.0.00 , Hose: Water Pump Outlet To Wi Manifold Cart Part No Dc.123.02.0.00 , Hose: Thermostat Bypass To Bend Pipe Cart Part No Dc.123.04.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No Dc.305.01.0.00 , Fuel Pipe- Filter To Fip Cart Part No Dc.305.02.0.00 , Adaptor (For Overflow Valve) Cart Part No Dc.305.07.0.00 , Fuel Pipe Filter To Tank Cart Part No Dc.305.08.0.00 , Liner Piston Set: Ew28 3Rv Cart Part No Dc.399.01.0.00 , Wet Pm Kit (W/O Oil) For Dc.5801, D2.9620 - Ew28 Cart Part No Dc.999.20.0.Sp , Wet Pm Kit (W/O Oil) For Dc.1606.91, Dc.1605.91 Cart Part No Dc.999.21.0.Sp , Wet Pm Kit (W/O Oil) For Dc.9804, Dc.9803 - Ew28 Cart Part No Dc.999.22.0.Sp , Crank Pulley (Finish)(Bolted Type)(175.4 Pcd) Cart Part No Dd.019.03.0.00 , Bolt (Bearing Cap) Cart Part No Dv0.001.03.0.00 , Hollow Dowel(For Bearing Cap Bolt) Cart Part No Dv0.001.04.0.00 , Nozzle Body: Oil Spray Nozzle Cart Part No Dv0.001.05.0.00 , Special Banjo Bolt : Oil Spray Nozzle Cart Part No Dv0.001.06.0.00 , Lifting Hook Cart Part No Dv0.001.08.0.00 , Special Banjo Boltfor Oil Spay Nozzle Cart Part No Dv0.001.09.0.Pr , Crank Case Sub-Assembly Cart Part No Dv0.001.10.0.00 , Thrust Washertop Cart Part No Dv0.001.13.0.00 , Thrust Washerbottom Cart Part No Dv0.001.14.0.00 , Cam Bush Cart Part No Dv0.001.15.0.00 , Core Plug Hex Socket (M24x2) Cart Part No Dv0.001.16.0.00 , Core Plug Hex. Socket M33x3.5 Cart Part No Dv0.001.17.0.00 , Core Plug Hex. Socket M30x1.5 Cart Part No Dv0.001.18.0.00 , Grommet: 12 Dia Ferrule Cart Part No Dv0.001.21.0.00 , Grommet: 22 Dia Ferrule Cart Part No Dv0.001.22.0.00 , Ferrule: 12 Dia Cart Part No Dv0.001.23.0.00 , Ferrule: 22Dia Cart Part No Dv0.001.24.0.00 , Dish Plug (80Dia) Cart Part No Dv0.001.25.0.00 , Washer For Crankcase Plug Cart Part No Dv0.001.26.0.00 , Plug (Crankcase Oil Hole) Cart Part No Dv0.001.27.0.00 , Crank Case Assembly Cart Part No Dv0.001.30.0.00 , Spring Cart Part No Dv0.001.31.0.00 , Plunger: Relief Valve Cart Part No Dv0.001.32.0.00 , M.B. Cross Bolt (Long) Cart Part No Dv0.001.42.0.00 , M.B. Cross Bolt (Short) Cart Part No Dv0.001.43.0.00 , Sealing Cap Cart Part No Dv0.001.47.0.00 , Relief Valve Assly Cart Part No Dv0.001.50.0.00 , Main Bearing Top ( Miba) Cart Part No Dv0.001.51.0.00 , Main Bearing Lower Half - Sputter+Syntec Cart Part No Dv0.001.77.0.00 , Grommet Support Washer-20.2 Cart Part No Dv0.001.81.0.00 , Grommet Support Washer-31.5D Cart Part No Dv0.001.82.0.00 , Grommet For 12Diaferrule Cart Part No Dv0.001.83.0.00 , Grommet Support Washer For 31 5 Cart Part No Dv0.001.85.0.00 , O Ring: Cylinder Liner Cart Part No Dv0.002.02.0.00 , Scraper Ring Cart Part No Dv0.002.04.0.00 , Cylinder Liner Assembly Cart Part No Dv0.002.10.0.Sp , Cylinder Liner Assembly Cart Part No Dv0.002.30.0.00 , Dowel Cart Part No Dv0.003.04.0.00 , Crankshaft Sub Assly. Cart Part No Dv0.003.10.0.00 , Crank Pulley Cart Part No Dv0.003.12.0.00 , Crank Pulley For Fan Drive Cart Part No Dv0.003.13.0.00 , Crank Pulley Bolt Cart Part No Dv0.003.14.0.00 , Special Bolt (For Cam Shaft) Cart Part No Dv0.004.06.0.00 , Thrust Plate: Cam Shaft: Width 18.2 Cart Part No Dv0.004.09.0.00 , Thrust Plate: Cam Shaft: Width 18.7 Cart Part No Dv0.004.11.0.00 , Thrust Plate For Camshaft17 5 Mm Thick Cart Part No Dv0.004.13.0.00 , Thrust Plate For Camshaft17 3 Mmthick Cart Part No Dv0.004.14.0.00 , Camshaft With Internal Egr With 1.25 Mm Secondary Lift Cart Part No Dv0.004.24.0.00 , Connecting Rod Bolt Cart Part No Dv0.005.02.0.00 , Big End Bearing Top Miba Cart Part No Dv0.005.11.0.00 , Big End Bearing Bottommiba Cart Part No Dv0.005.12.0.00 , Connecting Rod Assly.With Small End Bushwith Large End Bearing Cart Part No Dv0.005.20.0.00 , Assy. Connecting Rod (Machining With Small End Bush) (For Crdi Engine) Cart Part No Dv0.005.60.0.00 , Piston Pin Cart Part No Dv0.006.02.0.00 , Circlip(For Piston) Cart Part No Dv0.006.06.0.00 , Piston Ring Set Cart Part No Dv0.006.20.0.Sp , Piston Assembly Cart Part No Dv0.006.30.0.00 , Cylinder Head Bolt Cart Part No Dv0.007.02.0.00 , Core Plug (20 Mm Dia) Cart Part No Dv0.007.03.0.00 , Exhaust Valve Cart Part No Dv0.007.05.0.00 , Inlet Valve Seat Insert Semi-Finish Cart Part No Dv0.007.06.9.00 , Core Plug (Dia 32 Mm) Cart Part No Dv0.007.09.0.00 , Cylinderhead Gasket1 2 Thick Cart Part No Dv0.007.11.0.00 , Rocker Lever Adj. Screw Assly. Cart Part No Dv0.007.110.0.00 , Union Adaptor M12xm8 Cart Part No Dv0.007.113.0.00 , Nozzle Clamp Cart Part No Dv0.007.114.0.Pr , Nutfor Rocker Lever Adjscrew Cart Part No Dv0.007.18.0.00 , Bushrocker Lever Cart Part No Dv0.007.21.0.00 , Cylinder Head Sub Assembly (With Valve Seat & Valve Guide) Cart Part No Dv0.007.220.0.00 , Cylinder Head Sub Assemblywith Valve Spring Valvefor Cr Cart Part No Dv0.007.230.0.Pr , Cylinder Head Assembly Cart Part No Dv0.007.260.0.Pr , Nozzle Clamp Cart Part No Dv0.007.33.0.00 , Button For Nozzle Clamp Cart Part No Dv0.007.34.0.00 , Cup Washer For Nozzle Clamp Cart Part No Dv0.007.35.0.00 , Oil Metering Plug: Rocker Support Cart Part No Dv0.007.36.0.00 , Exhaust Valve Seat Insert Cart Part No Dv0.007.39.9.00 , Gasket: Cylinder Head 1 Thk Cart Part No Dv0.007.42.0.00 , Gasket: Cylinder Head 1.15 Thk Cart Part No Dv0.007.43.0.00 , Sealing Cap Cart Part No Dv0.007.46.0.00 , Rocker Lever Asslembly Cart Part No Dv0.007.60.0.00 , Valve Pair Cart Part No Dv0.007.65.0.00 , Cyl Head Sub Assemblywith Spring Valve Cart Part No Dv0.007.70.0.00 , Sealing Cap (For Dia 25) Cart Part No Dv0.007.71.0.00 , Cylinder Head Assly Cart Part No Dv0.007.75.0.00 , Valve Guidefinish Cart Part No Dv0.007.82.0.00 , Valve Guide (Semi-Finish) Cart Part No Dv0.007.82.9.00 , Cylinder Head Assembly Cart Part No Dv0.007.90.0.00 , Cylinder Head Bolt Cart Part No Dv0.007.93.0.00 , Lifting Hook Cart Part No Dv0.007.94.0.00 , Inlet Valvebimetal Cart Part No Dv0.007.96.0.00 , Inlet Valvebimetal Cart Part No Dv0.007.96.0.Pr , Inlet & Exhaust Valve Pair Cart Part No Dv0.007.96.0.Sp , Valve Seat Insert (Exhaust) (Semifinish) Cart Part No Dv0.007.98.9.00 , Injector Cart Part No Dv0.008.13.0.00 , O Ring For Injector Cart Part No Dv0.008.18.0.00 , Joint: Rocker Cover Metallic Cart Part No Dv0.009.05.0.00 , Rocker Cover Cart Part No Dv0.009.07.0.00 , Rocker Box Cart Part No Dv0.009.11.0.00 , Retainer Patefor Gear Support Cart Part No Dv0.010.03.0.00 , Thrust Washer: Intermediate Gear Support Cart Part No Dv0.010.04.0.00 , Thrust Washer: Intermediate Gear Support Cart Part No Dv0.010.06.0.00 , Double Gear Asslycrank Gear And Cam Gear Cart Part No Dv0.010.20.0.00 , Double Gear Support Cart Part No Dv0.010.25.0.Pr , Intermediate Gear Support Cart Part No Dv0.011.03.0.00 , Thrust Washer(39Mm Thick) Cart Part No Dv0.011.04.0.00 , Oil Seal Housing Cart Part No Dv0.012.01.0.00 , Joint: Oil Seal Housing Cart Part No Dv0.012.03.0.00 , Deflector For Pulley End Cart Part No Dv0.012.08.0.00 , Oil Seal Housing (Sub Assy) Cart Part No Dv0.012.11.0.00 , Oil Seal Pulley End Cart Part No Dv0.012.22.0.Pr , Int Gear Supportfor Lub Oil Pump Gear Cart Part No Dv0.013.08.0.00 , Lub Oil Pump Assebly Cart Part No Dv0.013.200.0.00 , Bush For Intgearlop Cart Part No Dv0.013.22.0.00 , Lube Oil Cooler (17 Plates) Cart Part No Dv0.014.01.0.00 , Lub Oil Cooler Header Cart Part No Dv0.014.04.0.Sp , Filter Header Cart Part No Dv0.014.05.0.00 , Joint: Cooler Cover Cart Part No Dv0.014.06.0.00 , Threaded Adaptor For Header Cart Part No Dv0.014.07.0.00 , Suction Tube Cart Part No Dv0.014.08.0.00 , Lub Oil Filter Header Asslywith Adaptor Core Plug Cart Part No Dv0.014.10.0.00 , Lube Oil Filter Cart Part No Dv0.014.11.0.00 , O Ring 38 Dia: L.O. Header Cart Part No Dv0.014.12.0.00 , O Ring 58 Dia: L.O. Header Cart Part No Dv0.014.13.0.00 , O Ring 67 Dia: L.O. Header Cart Part No Dv0.014.14.0.00 , Joint: Water Pump Suction Cart Part No Dv0.014.16.0.00 , Gasket (Lub. Oil Header) Cart Part No Dv0.014.17.0.00 , Joint: Suction Pipe Assly Cart Part No Dv0.014.18.0.00 , O Ring 29Dia: Element Oil Cooler Cart Part No Dv0.014.23.0.00 , Hose: Radiator To Suction Pipe Cart Part No Dv0.014.24.0.00 , Hose: Engine Water Out Cart Part No Dv0.014.25.0.00 , Metalic Pipe From Thermostat To Rad Cart Part No Dv0.014.26.0.00 , Lube Oil Filter Cart Part No Dv0.014.27.0.00 , Hose: Pipe To Thermostat Cart Part No Dv0.014.33.0.00 , Header For Oil Filter (320 Kva) Cart Part No Dv0.014.38.0.00 , Lube Oil Cooler Cover (Machining) Cart Part No Dv0.014.39.0.00 , Oil Filter Cart Part No Dv0.014.42.0.00 , Dome Nut: Lub Oil Cooler Cart Part No Dv0.014.43.0.00 , Lub Oil Cooler Header Assly Cart Part No Dv0.014.50.0.00 , Joint: Cooler Cover Cart Part No Dv0.014.51.0.00 , Lube Oil Filter Full Flow Spin On Cart Part No Dv0.014.66.0.00 , Lube Oil Filter By Pass Spin On Cart Part No Dv0.014.67.0.00 , Adaptor (For Lube Filter) (Full Flow Side) Cart Part No Dv0.014.68.0.Pr , Adaptor (For Lube Filter) (By-Pass Side) Cart Part No Dv0.014.69.0.Pr , Lube Oil Filter-Full Flow-Spin On Kirloskar Logo Reversal Application Cart Part No Dv0.014.72.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No Dv0.014.83.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv0.014.85.0.Sp , 50 Hours Service Maintenance Kit Cart Part No Dv0.014.86.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv0.014.89.0.Sp , Thermostat Element Cart Part No Dv0.015.01.0.00 , Thermostat Housing Cart Part No Dv0.015.02.0.00 , Thermostat Housing Cover Cart Part No Dv0.015.03.0.00 , Joint: Thermostat Housing Cart Part No Dv0.015.05.0.00 , Gasket: Thermostat Cover Cart Part No Dv0.015.06.0.00 , Washer: Thermostat Housing Assly Cart Part No Dv0.015.07.0.00 , Thermostat Housing Cart Part No Dv0.015.12.0.Pr , Thermostat Housing Cover Cart Part No Dv0.015.17.0.Pr , V Belt: Bx58 Pitch 1520 Long Cart Part No Dv0.016.08.0.00 , Joint:Bet Water Pump Hsg & Header Cart Part No Dv0.016.09.0.00 , Water Pump Pulley-115 Pcd Cart Part No Dv0.016.21.0.00 , V Wrapped Belt Ar1170 Spb Cart Part No Dv0.016.23.0.00 , V Wrapped Belt: Spb Ar1230 - 3 Set Cart Part No Dv0.016.25.0.00 , Fan Drive Belt (Bx 1230Lp Ar X 3) Cart Part No Dv0.016.27.0.Pr , Deep Groove Ball Brg. Cart Part No Dv0.016.36.0.Pr , Belt V Section (Bx 58- Pitch Length 1530 Mm) Cart Part No Dv0.016.42.0.Pr , Water Pump Assly Cart Part No Dv0.016.60.0.00 , Lube Oil Sump Cart Part No Dv0.017.03.0.00 , O Ring For Dipstick Plug Cart Part No Dv0.017.07.0.00 , Dipstick Assly Cart Part No Dv0.017.30.0.00 , Dipstick Assembly Cart Part No Dv0.017.80.0.00 , Dipstick Assly Cart Part No Dv0.017.90.0.Pr , Tappet Cart Part No Dv0.018.01.0.00 , Push Rod Assly Cart Part No Dv0.018.10.0.00 , Rubber Bush :Bottom Cart Part No Dv0.018.11.0.00 , Assly Push Rod Cover Tube Cart Part No Dv0.018.20.0.00 , Rubber Bush Bottom Cart Part No Dv0.018.23.0.00 , Push Rod Cover Tube Assembly (For Common Rail ) Cart Part No Dv0.018.40.0.00 , Fuel Pump Cap Cart Part No Dv0.019.11.0.00 , Fuel Filter: Dv10 Cart Part No Dv0.020.01.0.00 , Fuel Filter Cartridge Cart Part No Dv0.020.03.0.00 , High Pressure Pipe Assembly Cart Part No Dv0.021.130.0.00 , Clamp Cover For H Ppipe Cart Part No Dv0.021.52.0.Pr , Rubber Sleeve For H.P. Pipe Clamp Cart Part No Dv0.021.53.0.00 , High Pressure Pipes Assembly Cart Part No Dv0.021.710.0.Pr , Hp Pipe Assemblyfor Cyl1 Cart Part No Dv0.021.75.0.Pr , Hp Pipe Assemblyfor Cyl2 Cart Part No Dv0.021.76.0.Pr , Hp Pipe Assemblyfor Cyl3 Cart Part No Dv0.021.77.0.Pr , Hp Pipe Assemblyfor Cyl6 Cart Part No Dv0.021.78.0.Pr , Hp Pipe Assemblyfor Cyl7 Cart Part No Dv0.021.79.0.Pr , Hp Pipe Assemblypump To Rail Lhs From Fwe Cart Part No Dv0.021.81.0.00 , Hp Pipe Assly (Pump To Rail Rh From Fwe) Cart Part No Dv0.021.82.0.Pr , Rail Assembly 1 (Pulley End) Cart Part No Dv0.021.86.0.Pr , Adaptorone Side M16x1 5 Other Side M14x1 5 Cart Part No Dv0.022.05.0.00 , Elbow Connection (M16x15) Cart Part No Dv0.022.06.0.00 , Oil Supply Pipecrankcase To Fuel Pump In Cart Part No Dv0.022.102.0.Pr , Adaptor With Ferrule & Nut Assly Cart Part No Dv0.022.103.0.Pr , Adaptor With Ferrule & Nut Assly Cart Part No Dv0.022.106.0.Pr , Elbow Connection Cart Part No Dv0.022.108.0.Pr , Fuel Pipe Assly Flexible Cart Part No Dv0.022.110.0.00 , Hose For Oil Pipe Cart Part No Dv0.022.118.0.Pr , Nozzle Leak Off Pipe Cart Part No Dv0.022.15.0.00 , Fuel Pipe For Nozzle Leak Off Cart Part No Dv0.022.155.0.Pr , Parkar: Ge10lredcf Cart Part No Dv0.022.171.0.Pr , Parkar: G10lcfx Cart Part No Dv0.022.175.0.Pr , Parkar: Rhd10lomdcf Cart Part No Dv0.022.179.0.Pr , Parkar: Rbp110x Cart Part No Dv0.022.181.0.Pr , Adaptorfor Fuel Pipe Cart Part No Dv0.022.182.0.Pr , Bracket-1 Cart Part No Dv0.022.185.0.00 , Bracket Cart Part No Dv0.022.188.0.Pr , Bracket Cart Part No Dv0.022.189.0.00 , Clamp (2P) Cart Part No Dv0.022.191.0.Pr , Bracket Cart Part No Dv0.022.192.0.Pr , Hose For Intake 1 Cart Part No Dv0.022.194.0.Pr , Metal Tube (For Fuel Intake-1) Cart Part No Dv0.022.195.0.00 , Hose For Intake 2 Cart Part No Dv0.022.196.0.Pr , Metal Tube (For Fuel Intake-2) Cart Part No Dv0.022.197.0.00 , Hose For Fip Return Cart Part No Dv0.022.198.0.Pr , Metal Tube (For Fip Return) Cart Part No Dv0.022.199.0.00 , Bracket (For Lp Pipe-7) Cart Part No Dv0.022.202.0.Pr , Metal Tubefor Nozzle Leakoff Cart Part No Dv0.022.203.0.Pr , Injector Leak Off Pipe Cart Part No Dv0.022.204.0.Pr , Clamp For Fuel Pipe (Id19.5) Cart Part No Dv0.022.206.0.00 , Bracket Mtg. Plate Cart Part No Dv0.022.207.0.Pr , Bracket Cart Part No Dv0.022.208.0.Pr , Bracket Cart Part No Dv0.022.209.0.Pr , Plate For Clamp Cart Part No Dv0.022.211.0.Pr , Injector Leakoff Pipea Bank Cart Part No Dv0.022.213.0.Pr , Injector Leakoff Pipeb Bank Cart Part No Dv0.022.214.0.Pr , Fuel Pipefrom Tee To Tank Interface Cart Part No Dv0.022.215.0.Pr , Fuel Pipefrom Filter To Pump Lh From Fe Cart Part No Dv0.022.216.0.Pr , Fuel Pipefrom Filter To Adaptor Rh From Fe Cart Part No Dv0.022.217.0.00 , Fuel Pipe(From Adaptor To Pump Rh From F.E.) Cart Part No Dv0.022.218.0.Pr , Pump Leak Off Pipe-1 (Lh From F.E.) Cart Part No Dv0.022.219.0.Pr , Pump Leak Off Pipe-2 (Lh From F.E.) Cart Part No Dv0.022.221.0.Pr , Pump Leak Off Piperh From F E Cart Part No Dv0.022.222.0.Pr , Rail Leak Off Pipe Assembly Cart Part No Dv0.022.226.0.Pr , Dearation Pipe 1 A Bank Cart Part No Dv0.022.228.0.Pr , Dearation Pipe 2 B Bank Cart Part No Dv0.022.229.0.Pr , Adaptor M18*1.5-M14*1.5 (For Fuel Pump Oil Drain Pipe) Cart Part No Dv0.022.47.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv0.022.71.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No Dv0.022.72.0.00 , Feed Pump Fuel In Pipe: Flex Cart Part No Dv0.022.73.0.00 , Fuel Pipe: Pump Leak Off (Flex) Cart Part No Dv0.022.74.0.00 , Fuel Pipe: Nozzle Leak Off Flex Cart Part No Dv0.022.76.0.00 , Clamp For Low Pressure (3 Pipe) Cart Part No Dv0.022.77.0.00 , Rubber Sleeve For Low Pressure 3 Pipe Clamp Cart Part No Dv0.022.78.0.00 , Clamp 2 Pipe Cart Part No Dv0.022.86.0.00 , Drain Pipe (For Diesel Drain) Cart Part No Dv0.022.94.0.00 , Joint: Main Air Pipe To Inlet Manifold Cart Part No Dv0.023.02.0.00 , Joint: Bet Inlet Manifold & Cyl Head Cart Part No Dv0.023.03.0.00 , Cover Platefor Inlet Manifold Cart Part No Dv0.023.06.0.00 , Inlet Manifold 2 Port Cart Part No Dv0.023.08.0.00 , Inlet Manifold 3 Port Cart Part No Dv0.023.09.0.00 , Expansion Bellow Cart Part No Dv0.023.11.0.00 , Air Pipe Clamp (Bottom) Cart Part No Dv0.023.12.0.00 , Air Pipe Clamp (Top) Cart Part No Dv0.023.13.0.00 , Rubber Bush Cart Part No Dv0.023.14.0.00 , Expansion Bellow: Exp Mfold Cart Part No Dv0.024.05.0.00 , Joint: Exh Mani & Adaptor Cart Part No Dv0.024.06.0.00 , Joint: Exh.Mani And Cyl. Head Cart Part No Dv0.024.07.0.00 , Joint: Bet Exh Mfold & Exp Bellow Cart Part No Dv0.024.08.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.09.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.15.0.00 , Special Nut For Exhaust Manifold Cart Part No Dv0.024.18.0.00 , Stud: Exhaust Manifold Cart Part No Dv0.024.19.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.22.0.00 , Exhaust Manifoldl H3 Port Cart Part No Dv0.024.24.0.00 , Exhaust Manifold (L.H. 2 Port) Cart Part No Dv0.024.25.0.00 , Exhaust Manifoldr H3 Port Cart Part No Dv0.024.26.0.00 , Exhaust Manifoldr H2 Port Cart Part No Dv0.024.27.0.00 , Jointbetturbo Adaptor Exhaust Manifold Cart Part No Dv0.024.35.0.00 , Joint: Gear Casing Cart Part No Dv0.025.03.0.00 , Socket Head Screw (M12 X 165) Cart Part No Dv0.025.05.0.00 , Gear Cover Cum Bell Housing Cart Part No Dv0.025.14.0.00 , Deflector Cart Part No Dv0.025.17.0.00 , Oil Seal Flywheel End Cart Part No Dv0.025.18.0.Pr , Deflector For Flywheel End Cart Part No Dv0.025.19.0.Pr , Mud Slinger Fwe Cart Part No Dv0.025.21.0.Pr , Gear Cover Cum Bell Housing Dv0 025 23 0 Pr Cart Part No Dv0.025.23.0.Spr , Gear Casingfor Dv10 Crdi Cart Part No Dv0.025.25.0.00 , Bolt: Flywheel Cart Part No Dv0.026.02.0.00 , Washer (For Flywheel Bolt) Cart Part No Dv0.026.04.0.00 , Sub Asslyof Flywheel And Starter Ring Cart Part No Dv0.026.50.0.00 , Special Stud (For Starter) Cart Part No Dv0.027.03.0.00 , Starter 50Mt Cart Part No Dv0.027.11.0.00 , Lucas Starter 9 0Kw Sm50 Series For Dv Engine Cart Part No Dv0.027.12.0.Pr , Starterdelco Remy 50Mt Reil Series R50 Type 400Rdso Specs Rdso Pe Spec Ac Cart Part No Dv0.027.13.0.Pr , Prestolite Starter 9Kw Ms7 303K Design Cart Part No Dv0.027.14.0.Pr , Fan Pulley Cart Part No Dv0.029.01.0.00 , Bracket For Fan Drive Mounting Cart Part No Dv0.029.03.0.00 , Shaft: Radiator Fan Cart Part No Dv0.029.04.0.00 , Washer (For Fan Drive Pulley) Cart Part No Dv0.029.06.0.00 , Special Stud Cart Part No Dv0.029.07.0.00 , Fan Spacer Cart Part No Dv0.029.15.0.00 , Fan Spacer 80 Mm Cart Part No Dv0.029.17.0.00 , V Belt Cart Part No Dv0.029.18.0.Pr , Vbeltbx 1170 Ar Epdm Cart Part No Dv0.029.21.0.Pr , Fan Drive Asm: 3 Groove Pulley Cart Part No Dv0.029.210.0.00 , Fan Drive Asm3 Groove Pulley Cart Part No Dv0.029.220.0.Pr , Fan Drive Asm (3 Groove Pulley) Cart Part No Dv0.029.230.0.Pr , Fan Drive Asm Cart Part No Dv0.029.30.0.00 , Bearing Housing For Fan Drive Cart Part No Dv0.029.32.0.00 , Belt Bx 1170 Ar 2 Set Cart Part No Dv0.029.34.0.Pr , Damper Cart Part No Dv0.030.03.0.00 , Damper Cart Part No Dv0.030.09.0.00 , Timing Poinerfor Pulley Cart Part No Dv0.030.11.0.Pr , Angle Stripfor Tappet Fitting Cart Part No Dv0.030.12.0.Pr , Hose: Cac Cart Part No Dv0.031.03.0.00 , Breather Pipe Cart Part No Dv0.031.05.0.00 , Breather Hose Cart Part No Dv0.031.06.0.00 , Clip For Breather Pipe Cart Part No Dv0.031.21.0.00 , Radiator Fan (40) Cart Part No Dv0.031.24.0.00 , 44Fan For Dv10 Cart Part No Dv0.031.27.0.Pr , Radiator Cart Part No Dv0.031.30.0.00 , Radiator Pressure Cap Cart Part No Dv0.031.36.0.Pr , Radiator Assembly Dv0 031 39 0 Pr Cart Part No Dv0.031.39.0.Spr , Copper Radiator Assembly Cart Part No Dv0.031.45.0.Pr , Hose Heat Exchanger To Engine Pipe Cart Part No Dv0.031.51.0.00 , Hose For Cac To Heat Exchanger Pipe Cart Part No Dv0.031.52.0.00 , Pipe Thermostat To H E Cart Part No Dv0.031.54.0.00 , Suction Pipe (For Dv10) Cart Part No Dv0.031.56.0.00 , Joint For He Cart Part No Dv0.031.67.0.00 , Breather Hose Cart Part No Dv0.031.70.0.00 , Aluminium Radiator Assembly Cart Part No Dv0.031.78.0.Pr , Clamp Assembly For Water Outlet Pipe Cart Part No Dv0.031.80.0.00 , Aluminium Radiator Assembly Cart Part No Dv0.031.87.0.Pr , Aluminium Radiator Assembly Cart Part No Dv0.031.88.0.Pr , Hose For Raw Wtaerhe Cart Part No Dv0.031.97.0.Pr , Joint: Adaptor & Turbo Cart Part No Dv0.032.04.0.00 , Joint: Flange For T/C Lube Oil Outlet Pipe Cart Part No Dv0.032.06.0.00 , Flange With Adaptor (For Turbo Drain) Cart Part No Dv0.032.08.0.00 , Clamping Spacer Cart Part No Dv0.032.12.0.00 , Oil Supply Pipe L.H. Cart Part No Dv0.032.122.0.Pr , Oil Supply Pipe R.H. Cart Part No Dv0.032.123.0.Pr , Guard For Motor Cart Part No Dv0.032.124.0.Pr , Turbo Adaptor Cart Part No Dv0.032.18.0.00 , Turbo Adaptor Cart Part No Dv0.032.19.0.00 , Oil Supply Pipe L.H. : Modified Mfold (Crankcase To T/C In) Cart Part No Dv0.032.28.0.00 , Oil Supply Pipe R.H. : Modified Mfold (Crankcase To T/C In) Cart Part No Dv0.032.29.0.00 , Joint Cart Part No Dv0.032.33.0.00 , Turbo Adaptor (Lh From G.E.) Cart Part No Dv0.032.37.0.00 , Oil Supply Pipe Rh- Crank Case- Turbocharger Cart Part No Dv0.032.38.0.00 , Oil Supply Pipe L H From Crankacse To Turbocharger Cart Part No Dv0.032.39.0.00 , Turbo Drain Pipe Cart Part No Dv0.032.43.0.00 , Gasket For Turbocharger Cart Part No Dv0.032.45.0.Pr , Adaptorm30x1 5 X Both Sides Cart Part No Dv0.032.46.0.00 , Suction Pipe Engine To Radiator Cart Part No Dv0.032.73.0.00 , Breather Pipe Cart Part No Dv0.032.76.0.00 , Bracket For Breather Pipe Cart Part No Dv0.032.78.0.00 , Breather Hose Cart Part No Dv0.032.79.0.00 , Turbo Drain Pipe Cart Part No Dv0.032.82.0.Pr , Left Bank Tcharger: Dv10 Cart Part No Dv0.032.97.0.00 , Right Bank Tcharger: Dv10 Cart Part No Dv0.032.98.0.00 , Air Pipe Cart Part No Dv0.033.03.0.00 , Air Inlet Pipe From Cac Cart Part No Dv0.033.100.0.Pr , Support Bracket Cart Part No Dv0.033.104.0.Pr , Joint: Main Air Pipe Horizontal & Vertical Cart Part No Dv0.033.11.0.00 , Oring For Cac Pipe Cart Part No Dv0.033.116.0.Pr , Joint: Main Air Pipe And Ver Pipe Cart Part No Dv0.033.12.0.00 , Joint: Main Air Pipe Hor+Ver Cart Part No Dv0.033.13.0.00 , Joint: Bet Bend To Air Pipe Cart Part No Dv0.033.14.0.00 , Exhaust Elbow (Lhs From Fwe) Cart Part No Dv0.033.17.0.00 , Exhaust Elbow (Rhs From Fwe) Cart Part No Dv0.033.18.0.00 , Bracketfor Air Pipe Mounting Cart Part No Dv0.033.25.0.00 , Air Inlet Pipe T/C To Cac Cart Part No Dv0.033.26.0.00 , Joint For Air Inlet Pipe To Cac Cart Part No Dv0.033.27.0.00 , Air Inlet Pipe From Cac Cart Part No Dv0.033.28.0.00 , V Clamp: Turbo Cart Part No Dv0.033.33.0.00 , Turbo Compressor Out Pipe (Lhview From Fwe) Cart Part No Dv0.033.34.0.00 , Turbo Compressor Out Pipe (Rhview From Fwe) Cart Part No Dv0.033.35.0.00 , O Ring (For Compressor Out Pipe) Cart Part No Dv0.033.38.0.00 , Joining Plate Cart Part No Dv0.033.45.0.00 , Main Air Pipe (Horizontal Cac Inlet) Cart Part No Dv0.033.61.0.00 , Fuel Filter Bracket Cart Part No Dv0.033.63.0.00 , V-B& Clamp (88Mm Nominal Dia) Cart Part No Dv0.033.67.0.00 , Expansion Bellow: 6 Id Cart Part No Dv0.033.70.0.00 , Joint: Exhaust Bend And Expansion Bellow Cart Part No Dv0.033.73.0.00 , Joint: Extension Pipe And Exhaust Silencer Cart Part No Dv0.033.74.0.00 , Main Air Pipe (Horizontal Cac Out) Cart Part No Dv0.033.75.0.00 , V Band Clamp Cart Part No Dv0.033.79.0.Pr , Air Pipe Cart Part No Dv0.033.85.0.Pr , Cac Hose (Hot Side) Cart Part No Dv0.033.88.0.Pr , Radiator Fanrailway Application Cart Part No Dv0.033.90.0.Sp , Bracket (Air Inlet Pipe From Cac) Cart Part No Dv0.033.91.0.00 , Clamp For Air Inlet Pipe From Cac Cart Part No Dv0.033.92.0.00 , Rubber Sleeve For Air Inlet Pipe From Cac Cart Part No Dv0.033.94.0.Pr , Clamp For Air Inlet Pipe Tc To Cac Cart Part No Dv0.033.96.0.Pr , Clamp For Air Inlet Pipe Tc To Cac Cart Part No Dv0.033.97.0.Pr , Rubber Sleeve For Air Inlet Pipe T C To Cac Cart Part No Dv0.033.98.0.Pr , Air Inlet Pipe T C To Cac Cart Part No Dv0.033.99.0.Pr , Engine Mtd. Foot Cart Part No Dv0.034.13.0.00 , Hose Reducer Elbow: Dv10 Cart Part No Dv0.035.04.0.00 , Hose: Reducer Elbow Cart Part No Dv0.035.08.0.00 , Pipe Assembly Powder Coated (Dv8/Dv10) Cart Part No Dv0.035.13.0.00 , Fan Guard For Radiator Dv0.031.88.0.Pr Cart Part No Dv0.037.10.0.Sp , Feed Pump Cart Part No Dv0.040.01.0.00 , Drive End Bearing Cart Part No Dv0.040.04.0.00 , Governer End Bearing Cart Part No Dv0.040.05.0.00 , Intermediate Support Bearing For Cam Shaft Cart Part No Dv0.040.06.0.00 , Oil Seal For Drive End Cart Part No Dv0.040.07.0.00 , Oil Seal Housing Cart Part No Dv0.040.08.0.00 , O Ring: Oil Seal Housing Cart Part No Dv0.040.09.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.10.0.00 , Locking Nut For Gear Mounting Flange Cart Part No Dv0.040.11.0.00 , Gear Mounting Flangehub Cart Part No Dv0.040.115.0.00 , Flat Seal For Oil Seal Housing Cart Part No Dv0.040.116.0.00 , Cam Shaft Cart Part No Dv0.040.117.0.00 , Governor Mounting Plate Cart Part No Dv0.040.14.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.140.0.Pr , Non Return Valve (1.4 Bar) Cart Part No Dv0.040.157.0.Pr , End Support Bush For Rack Cart Part No Dv0.040.21.0.00 , Rack Support Adj. Screw Cart Part No Dv0.040.23.0.00 , Dome Nut For Rack Support Cart Part No Dv0.040.24.0.00 , Locking Screw For Rack Cart Part No Dv0.040.25.0.00 , Pf33 Individual Pump Cart Part No Dv0.040.27.0.00 , Roller Tappet Assly. Cart Part No Dv0.040.30.0.00 , Pf 33 Pump Mounting Flange Cart Part No Dv0.040.36.0.00 , Plugs For Oil Gallery Cross Holes Cart Part No Dv0.040.44.0.00 , Core Plug For Fuel Pump (Bottom Side) Cart Part No Dv0.040.48.0.00 , Cap Nut For Rack Driving Side Cart Part No Dv0.040.49.0.00 , Stud For Pump Mounting Cart Part No Dv0.040.53.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.540.0.Pr , Line Hand Primer Cart Part No Dv0.040.56.0.00 , Core Plug For Fuel Gallery Cart Part No Dv0.040.57.0.00 , Breather Screw Cart Part No Dv0.040.58.0.00 , Vent For Breather Screw Cart Part No Dv0.040.59.0.00 , Lock For End Support Bush Cart Part No Dv0.040.61.0.00 , Washer For Fip Mounting Cart Part No Dv0.040.63.0.00 , Spherical Washer: Fip Mtg Cart Part No Dv0.040.64.0.00 , Shim For Camshaft End Play (0.5Mm Thick) Cart Part No Dv0.040.65.0.00 , Shim For Roller Tapet(2.5Mm Thick) Cart Part No Dv0.040.66.0.00 , Shim For Roller Tappet (2.6Mm) Cart Part No Dv0.040.67.0.00 , Shim For Roller Tappet (2.7Mm Thick Cart Part No Dv0.040.68.0.00 , Shim For Camshaft Endplay(1.00Mm Thick) Cart Part No Dv0.040.69.0.00 , Dome Nut For Rack Locking Screw Cart Part No Dv0.040.71.0.00 , Shim For Roller Tappet (2.8Mm Thick) Cart Part No Dv0.040.74.0.00 , Shim For Roller Tappet (2.9Mm Thick) Cart Part No Dv0.040.75.0.00 , Banjo Bolt For Fip Oil Supply M8 X 1 25 Cart Part No Dv0.040.81.0.00 , Washer For Cap Nut Cart Part No Dv0.040.82.0.00 , Linkage Assembly For Governor Cart Part No Dv0.040.85.0.00 , Helicoil (M14x15x14 Mm Long) Cart Part No Dv0.040.91.0.00 , Speed Control Unit Cart Part No Dv0.040.92.0.00 , Actuator: 24V Cart Part No Dv0.040.93.0.00 , Joint: Governor Mounting Plate Cart Part No Dv0.040.98.0.00 , Joint: Centrifugal Adaptor & Filter Cart Part No Dv0.041.04.0.00 , Gasket: Oil Sump And Centrifuge Adaptor Cart Part No Dv0.041.07.0.00 , Adaptor For Centrifuge Filter Cart Part No Dv0.041.15.0.00 , Oil Filling Pipe Cart Part No Dv0.041.16.0.00 , O-Ring For Oil Filling Pipe Cart Part No Dv0.041.17.0.00 , Centrifuge Mtg.Assly Cart Part No Dv0.041.20.0.00 , Centrifugal Oil Cleaner (Band Design) Cart Part No Dv0.041.25.0.00 , Centrifuge Adaptor Cart Part No Dv0.041.42.0.00 , Oil Inlet Pipefrom Crankcase To Centrifuge Filter Cart Part No Dv0.041.46.0.00 , Joint: Delivery Tube Flange Cart Part No Dv0.042.03.0.00 , O Ring Dia 36: L.O. Delivery Tube Cart Part No Dv0.042.05.0.00 , Clamp (For Oil Delivery Tube) Cart Part No Dv0.042.07.0.00 , Strap Cart Part No Dv0.042.08.0.00 , Rubber Bush Cart Part No Dv0.042.09.0.00 , Delivery Tube Cart Part No Dv0.042.10.0.00 , Joint: Suction Tube Flange Cart Part No Dv0.043.05.0.00 , Suction Tubesub Assly Cart Part No Dv0.043.10.0.00 , Dowel Bush For Alternator Mounting Bracket Cart Part No Dv0.044.04.0.00 , Alternator Pulley Cart Part No Dv0.044.08.0.00 , Stud: Alternator Cart Part No Dv0.044.11.0.00 , Swivel Piece Cart Part No Dv0.044.12.0.00 , Eye Bolt: Alternator Cart Part No Dv0.044.13.0.00 , Charging Alternator Bracket Cart Part No Dv0.044.14.0.00 , Dowel Bolt: Alternator Cart Part No Dv0.044.15.0.00 , Counter Shunk Head Screw-Dv Injector Leakoff Cart Part No Dv0.045.03.0.00 , Clamp Assembly For Leak Off Pipe & Hppipe Cart Part No Dv0.045.30.0.00 , Breather Plate Cart Part No Dv0.046.01.0.00 , Breather Adaptor Cart Part No Dv0.046.02.0.00 , O Ring: Breather Plate Cart Part No Dv0.046.03.0.00 , Joint: Breather Plate & Adapter Cart Part No Dv0.046.04.0.00 , Crankcase Breather Cart Part No Dv0.046.07.0.00 , O Ring Cart Part No Dv0.046.09.0.00 , Hose: Radiator To Engine Cart Part No Dv0.048.02.0.00 , Heat Shield (R.H) Cart Part No Dv0.051.16.0.00 , Heat Shield (L.H) Cart Part No Dv0.051.17.0.00 , Upper Heat Shield Lh From Fwe Cart Part No Dv0.051.51.0.Pr , Lower Heat Shield Lh From Fwe Cart Part No Dv0.051.53.0.Pr , Upper Heat Shield Rh From Fwe Cart Part No Dv0.051.54.0.Pr , Lower Heat Shield Rh From Fwe Cart Part No Dv0.051.55.0.Pr , End Cover For Heat Shieldl Hfrom Fwe Cart Part No Dv0.051.56.0.Pr , End Cover For Heat Shieldr Hfrom Fwe Cart Part No Dv0.051.57.0.Pr , Heat Shield Sub Assemblyrh Side From Fwe End Cart Part No Dv0.051.60.0.Pr , Bracket-1 (For Heat Shield Mtg.) Cart Part No Dv0.051.63.0.Pr , Bracket-2 (For Heat Shield Mtg.) Cart Part No Dv0.051.64.0.Pr , Bracket-3 (For Heat Shield Mtg.) Cart Part No Dv0.051.65.0.Pr , Bracket (For Heat Shield Cover Mtg.) Cart Part No Dv0.051.66.0.Pr , Heat Shield Coverl Hside From Fwe Cart Part No Dv0.051.67.0.Pr , Heat Shield Coverr Hside From Fwe Cart Part No Dv0.051.68.0.Pr , Heat Sub Assemblylh Side From Fwe End Cart Part No Dv0.051.70.0.Pr , Spinon Preline Filter Ctg Cart Part No Dv0.053.05.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.01.0.00 , Anti Vibration Mount Pgs-3(N1)B Cart Part No Dv0.061.03.0.00 , Anti Vibration Mount Pgs 3800N1 Cart Part No Dv0.061.07.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.15.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.16.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.17.0.00 , Avm For 500Kva Rdso Projectgf B 70 Cart Part No Dv0.061.18.0.Pr , Joint: Dv10 Turbo Cart Part No Dv0.064.01.0.00 , Fuel Pipe Adaptor Cart Part No Dv0.069.04.0.00 , Adaptorfor Fuel Inlet Cart Part No Dv0.069.08.0.00 , Adaptor Cart Part No Dv0.069.47.0.00 , Oil Drain Pipe (Fip To Crank Case) Cart Part No Dv0.069.65.0.00 , Leak Off Pipe Cart Part No Dv0.069.85.0.00 , Vent Pipe Cart Part No Dv0.071.01.0.00 , Elbow Connection Cart Part No Dv0.071.02.0.00 , Vent Pipe For Radiator-750 Kva Cart Part No Dv0.071.03.0.00 , Common Rail Fuel Pump Gear Cart Part No Dv0.072.06.0.Pr , Common Rail Fuel Pump Assembly Cart Part No Dv0.072.60.0.00 , Joint For Barring Device Cart Part No Dv0.074.09.0.00 , Plastic Capwater Inlet Cart Part No Dv0.075.01.0.00 , Plastic Capcac Outlet Cart Part No Dv0.075.06.0.00 , Plastic Capcap Inlet Cart Part No Dv0.075.07.0.00 , Protection Plastic Capforintake Adaptor Cart Part No Dv0.075.15.0.Pr , Fan Clutch Asembly For Dv10 12 Cart Part No Dv0.076.40.0.00 , Flywheel Housing Cart Part No Dv0.086.16.0.00 , Hosebetinlet Manifold Cac Adaptor R H Cart Part No Dv0.086.37.0.00 , Cover For Gear Casing Cart Part No Dv0.086.39.0.00 , Sparkplug For Dv0 Gas Engine Cart Part No Dv0.087.30.0.Pr , Electronic Throttle Body F Tech Cart Part No Dv0.087.50.0.Pr , Ignition Coil For Dv Gas Engines Cart Part No Dv0.087.52.0.Pr , Uego Sensor For Gas Engines Cart Part No Dv0.087.53.0.Pr , Wiring Harness Boxlhs From Fwe Cart Part No Dv0.099.75.0.Pr , Wiring Harness Boxrhs From Fwe Cart Part No Dv0.099.77.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Dcu 1 Chamber 1 Cart Part No Dv0.112.10.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Dcu 1 Chamber 2 Cart Part No Dv0.112.20.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 1 Cart Part No Dv0.114.10.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 5/6/7 Cart Part No Dv0.114.30.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 8 Cart Part No Dv0.114.40.0.Pr , Dcu Connection Wiring Harness For Dv10 Engine Cpcb 4 Cart Part No Dv0.114.50.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv0.114.60.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb 4 Engineecu Chamber 1 Cart Part No Dv0.114.70.0.Pr , Radiator Drain Pipe For Dv Cart Part No Dv0.153.01.0.00 , Genset Kit (Rdso Power Car) Cart Part No Dv0.15Pk.01.0.00 , Silencer Assembly Cart Part No Dv0.188.20.0.00 , Ecuepc 1830 31 Md1ce200 Cart Part No Dv0.1999.01.0.Pr , Metallic Pipe Engine To Egtrhs Side From F W E Cart Part No Dv0.477.44.0.Pr , Hydraulic Pipe From Engine Out To Dosi Cart Part No Dv0.477.47.0.Pr , Hydraulic Pipe From Supply Module Out Cart Part No Dv0.477.49.0.Pr , Hydraulic Pipe From Supply Module Out Cart Part No Dv0.477.52.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-3) (Lhs Egt F.W.E.) Cart Part No Dv0.478.01.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-4) (Rhs Egt F.W.E.) Cart Part No Dv0.478.02.0.Pr , Hose Clamp Cart Part No Dv0.505.02.0.00 , Support For Air Cleaner Pipe Cart Part No Dv0.505.07.0.00 , Air Pipe Cart Part No Dv0.505.18.0.00 , Air Cleaner Kit Lh Cart Part No Dv0.505.30.0.00 , Air Cleaner Kit Rh Cart Part No Dv0.505.40.0.00 , Primary Element -Air Cart Part No Dv0.505.41.0.Pr , Air Filter Safety Cart Part No Dv0.505.42.0.Pr , Rubber Sleeve Cart Part No Dv0.506.01.0.00 , Air Cleaner Assembly For 500Kva Rdso Projectmcf Cart Part No Dv0.506.115.0.Pr , Air Cleaner Assembly ( L.H Side ) Cart Part No Dv0.506.30.0.00 , Air Cleaner Assembly ( R.H Side ) Cart Part No Dv0.506.40.0.00 , Fuel Pipe: Fuel Tank To Leak Off Pipe Cart Part No Dv0.507.02.0.00 , Fuel Pipe Fuel Tank -Fuel Filter Cart Part No Dv0.507.03.0.00 , Adaptor (M22 X 15- M18 X 15) Cart Part No Dv0.507.04.0.00 , Fuel Pipe - Pre Filter -Fip Cart Part No Dv0.507.15.0.00 , Adaptor (M8 X125 - M27 X 15) Cart Part No Dv0.507.19.0.00 , Inlet & Outlet Connection Cart Part No Dv0.507.25.0.00 , Fuel Pipe From Pre Filter To Feed Pump Cart Part No Dv0.507.34.0.Pr , Fuel Pipe Return Cart Part No Dv0.507.81.0.Pr , Fuel Pipe (From Tank To Pre Filter) Cart Part No Dv0.507.82.0.Pr , 24V55a Charging Alternator Cart Part No Dv0.639.01.0.Pr , Koel Green Alternatorkg500 S T Framel Kg 47 2 M7sae 1 14 415V50 Hz0 8 Pf Cart Part No Dv0.801.15.0.00 , 500 Kva750v Ac50hz3 Phase4 Wirelong Coupledframe Lstr 472 L Alternator F Cart Part No Dv0.801.33.0.Pr , Over Voltage Protection Unit Cart Part No Dv0.801.37.0.Sp , Fuel Level Sensor 225Mm Cart Part No Dv0.802.15.0.00 , Fuel Level Sensor 227Mm Cart Part No Dv0.802.25.0.00 , Fuel Level Sensor- 220Mm Height Cart Part No Dv0.802.35.0.00 , Fuel Transducersmart Cap 225 Eth Cart Part No Dv0.802.45.0.Pr , 4-20Ma Pressure Sensor Cart Part No Dv0.802.52.0.Pr , Drain Pipe For 500 Kva Rdso Project Cart Part No Dv0.806.89.0.Pr , Drain Pipe From Sump To Pump 500 Kva Rdso Project Cart Part No Dv0.806.91.0.Pr , Breather Hose For 500 Kva Rdso Project Cart Part No Dv0.806.93.0.Pr , Kent Oil Meter15mm Cart Part No Dv0.806.96.0.Pr , Bracket For Water Pipe Clamping Cart Part No Dv0.806.99.0.Pr , Belt Guard Cart Part No Dv0.807.02.0.Pr , Avm Of Radiator For 500Kva Rdso Project Cart Part No Dv0.807.03.0.Pr , Dse 2133 Rtd Thermocouple Input Expansion Module Cart Part No Dv0.807.111.0.00 , Cac Out Pipe Clamp Cart Part No Dv0.807.115.0.Pr , Coolant Pipe Support Bracket Assembly Cart Part No Dv0.807.116.0.Pr , Electromagnetic Vacuum Indicator Emviwith Connector Cart Part No Dv0.807.19.0.Pr , Matchweld Couplings Dia 76 1 Cart Part No Dv0.807.21.0.Pr , U Clamp For Fuel Flow Meter Clamping Cart Part No Dv0.807.24.0.Pr , Flexible Coupling Vulkon Cart Part No Dv0.807.26.0.Pr , Tubular Lead Acid Battery8v290ahrdso Approved Is7624 Compliant Cart Part No Dv0.807.34.0.Pr , U Clamp For Water Pipe Claming (Dia.76.1) Cart Part No Dv0.807.38.0.Pr , Adaptor For Vent Connection For 500 Kva Rdso Cart Part No Dv0.807.47.0.Pr , Air Flow Paddle Switch Cart Part No Dv0.807.48.0.Pr , Float Type Level Sensorthreadingeffective Length 90 Mm Cart Part No Dv0.807.52.0.Pr , Ventilation Blower Assembly Complete With Fan Motor Housing Brackets Suit Cart Part No Dv0.807.72.0.Pr , Roof Top Air Filter With Louverconfig 1X1 Cart Part No Dv0.807.89.0.Pr , Junction Box For Fuel Return Pipes Cart Part No Dv0.807.98.0.Pr , Exhaust Pipe Support Assembly Cart Part No Dv0.808.102.0.Pr , Suction Pipe Cart Part No Dv0.808.111.0.Pr , Coolant Pipe From Thermostst To Radiator India 76 2Mm Cart Part No Dv0.808.112.0.Pr , Air Inlet Pipe From Radiator Outlet To Engine In Cart Part No Dv0.808.114.0.Pr , Support Bracket For Radiator Cac Pipe Clamping Cart Part No Dv0.808.115.0.Pr , Flexible Air Vent Pipe Cart Part No Dv0.808.117.0.Pr , U Clamp For Cac Pipe Support Cart Part No Dv0.808.118.0.Pr , Heat Shield For Primary Silencer Cart Part No Dv0.808.128.0.Pr , Heat Shield For Secondary Silencer Cart Part No Dv0.808.129.0.Pr , Exhaust Gasket Cart Part No Dv0.808.132.0.Pr , Bracket For Fuel Water Seperator Mounting Cart Part No Dv0.808.141.0.Pr , Cover For Fuel Pipes At Starter Side Cart Part No Dv0.808.143.0.Pr , Flexible Inlet Fuel Pipe From Filter Outlet To Engine Inlet Cart Part No Dv0.808.144.0.Pr , Flexible Inlet Fuel Pipe 1 From Filter Outlet To Engine Inlet Cart Part No Dv0.808.145.0.Pr , Metallic Inlet Fuel Pipe From Filter Outlet To Engine Inlet Cart Part No Dv0.808.146.0.Pr , Metallic Inlet Fuel Pipe-1 From Filter Outlet To Engine Inlet Cart Part No Dv0.808.147.0.Pr , Adaptor M16x1 5M Sealxm22x1 5 M Cart Part No Dv0.808.148.0.Pr , Fuel Pipe From Flow Meter Outlet To Filter Inlet Cart Part No Dv0.808.149.0.Pr , Fuel Return Pipe From Tee To Flow Meter Cart Part No Dv0.808.152.0.Pr , Tube Clampsfor 2 Tubes Cart Part No Dv0.808.154.0.Pr , Tube Clampsfor 1 Tube Cart Part No Dv0.808.155.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.156.0.Pr , Union Adaptorm22x1 5 X M22x1 5 Cart Part No Dv0.808.157.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.159.0.Pr , Flexible Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.161.0.Pr , Flexible Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.163.0.Pr , Metallic Return Fuel Pipe From Flow Meter To Coach Tank Cart Part No Dv0.808.164.0.Pr , Flexible Return Fuel Pipe From Flow Meter To Coach Tank Cart Part No Dv0.808.165.0.Pr , Metallic Inlet Fuel Pipe From Coach Tank To Water Seperator Cart Part No Dv0.808.166.0.Pr , Tee Connectionm22x1 5 F Xm22x1 5 M Xm22x1 5 M Cart Part No Dv0.808.167.0.Pr , Bracket For Fuel Filter Mounting Cart Part No Dv0.808.168.0.Pr , Adaptor M22x1 5M Sealxm22x1 5 M Cart Part No Dv0.808.171.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.172.0.Pr , Adaptor Reducer M22x1 5 M Xm16x1 5 M Cart Part No Dv0.808.176.0.Pr , Adaptor Reducer M22x1 5 F X1 8Npt F Cart Part No Dv0.808.182.0.Pr , Cover For Fuel Pipes At Alternator Back Side Cart Part No Dv0.808.183.0.Pr , Hose For Air Cleaner Cart Part No Dv0.808.198.0.Pr , Adaptor - M30x2(M)X 1 B.S.P(F) Cart Part No Dv0.808.205.0.Pr , Hose Clamp T Bolt Cart Part No Dv0.808.208.0.Pr , Adaptor M22x1 5 Mx 1 B S Pf Cart Part No Dv0.808.212.0.Pr , Clamp For Engine Harness Cart Part No Dv0.808.216.0.Pr , Tray For Fuel Collector Cart Part No Dv0.808.217.0.Pr , Metallic Inlet Pipe From Flow Meter To Pump Cart Part No Dv0.808.221.0.Pr , Bracket For Pump Cart Part No Dv0.808.222.0.Pr , Tube Clamps Platefor Rbp215x Cart Part No Dv0.808.223.0.Pr , Digital Fuel Flow Meter Cart Part No Dv0.808.224.0.Pr , Bracket For Digital Fuel Flow Meter Cart Part No Dv0.808.225.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.226.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.227.0.Pr , Metallic Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.228.0.Pr , Bracket For Fuel Pipe Support Cart Part No Dv0.808.229.0.Pr , Support Bracket 1 For Air Suction Pipe Cart Part No Dv0.808.232.0.Pr , Support Bracket 2 For Air Suction Pipe Cart Part No Dv0.808.233.0.Pr , Flexible Vent Pipe For 500Kva Rdso Project Cart Part No Dv0.808.25.0.Pr , Y Pipe Mounting Bracket Cart Part No Dv0.808.256.0.Pr , Air Suction Pipe Cart Part No Dv0.808.266.0.Pr , Clamp For Water Piping Support Cart Part No Dv0.808.27.0.Pr , Support Plate For Radiator Cac Hose Cart Part No Dv0.808.29.0.Pr , Joint For Exhaust Junction Box Cart Part No Dv0.808.32.0.Pr , Joint For Air Suction Junction Box Cart Part No Dv0.808.34.0.Pr , Hose For Air Suction Pipe Cart Part No Dv0.808.36.0.Pr , Clamp For Reducer Hose Cart Part No Dv0.808.37.0.Pr , Adaptor For Lube Oil Temp Sensor Cart Part No Dv0.808.39.0.00 , Adaptor For Fuel Inlet And Return Pipe On Coach Piping Cart Part No Dv0.808.41.0.Pr , U Clamp For Cac Pipe Cart Part No Dv0.808.51.0.Pr , Joint For Air Suctionmounting On Caoch Cart Part No Dv0.808.59.0.Pr , Coolant Pipe From Thermostst To Radiator In Cart Part No Dv0.808.64.0.Pr , Suction Pipe Cart Part No Dv0.808.66.0.Pr , Coolant Pipe From Thermostst To Radiator India 76 2Mm Cart Part No Dv0.808.67.0.Pr , Expansion Bellow Cart Part No Dv0.808.78.0.Pr , Hose For Air Suction Pipe Cart Part No Dv0.808.82.0.Pr , Support Bracket For Exhaust Junction Box Cart Part No Dv0.808.83.0.Pr , Hose Clip T Bolt Type Cart Part No Dv0.808.84.0.Pr , Shim 0 1Mm Cart Part No Dv0.808.93.0.Pr , Shim 0 2Mm Cart Part No Dv0.808.94.0.Pr , Shim 0 5Mm Cart Part No Dv0.808.95.0.Pr , Shim 1 0Mm Cart Part No Dv0.808.96.0.Pr , Shim 2 0Mm Cart Part No Dv0.808.97.0.Pr , Accessories For Pump Flow Meter & Fuel Filter Mounting Cart Part No Dv0.809.18.0.00 , Accessories For Water Seperator Mounting Cart Part No Dv0.809.19.0.00 , Side Wall Air Filter With Louverconfig 3X3 Filters Cart Part No Dv0.809.73.0.Pr , Coolent Level Switch Cart Part No Dv0.812.22.0.Pr , Air Inlet Hose For 101 6 Od Cart Part No Dv0.821.12.0.Pr , Support Plate Cart Part No Dv0.821.15.0.Pr , Vent Pipe 3000Mm Cart Part No Dv0.822.41.0.Pr , Couplings Dia 127 For Cac Cart Part No Dv0.823.12.0.Pr , Door Visor For Dv Series Canopy Cart Part No Dv0.831.16.0.Pr , 1500 Hrs C Check Maintenance Kit Dv0 8501 C4 Dv0 8552 C4 Cart Part No Dv0.850.01.0.Sp , Relay Board 1.5 Ch 70 A Capa Cart Part No Dv0.853.07.0.00 , Relay Board 4 Channel Cart Part No Dv0.853.12.0.00 , Avr To Panel Wiring Harness Cart Part No Dv0.853.41.0.Pr , Communication Cable And Usb Converter Cable Cart Part No Dv0.853.45.0.Pr , Avr Harness For A Bank Cart Part No Dv0.853.46.0.Pr , Avr Harness For B Bank Cart Part No Dv0.853.47.0.Pr , Connector For Panel Side Cart Part No Dv0.853.50.0.00 , Connector For Panel Side Cart Part No Dv0.853.60.0.00 , Relay Board 24V Dc 2 Ch 2C/O Cart Part No Dv0.854.09.0.00 , Assembly For Krm Unit For Kg1500 With Pakage Cart Part No Dv0.858.01.0.Pr , Genset Controller 7320 Mk Ii Cart Part No Dv0.858.05.0.00 , Kg1500 Synchronization Controller Model No 8440 2219 Cart Part No Dv0.858.06.0.Pr , Engine Control Panel Assembly With Easy Gen 2500 Controller Cart Part No Dv0.859.10.0.Pr , Fresh Air In Temprature Sensortypertd Cart Part No Dv0.861.12.0.Pr , Dg Compartment Coach Temptemprature Sensortypertd Cart Part No Dv0.861.13.0.Pr , Exhaust Temperature Sensork Thermocouple Cart Part No Dv0.861.14.0.Pr , 24V 2.5Amp Trickle Charger Cart Part No Dv0.861.31.0.00 , Avr Model Tavr 60 Cart Part No Dv0.862.36.0.00 , P.T. 800/415 V5va Class -1 Cart Part No Dv0.868.07.0.00 , Genset Control Panel Assembly With Kg 745 Unit Cart Part No Dv0.868.10.0.Pr , Pc Engine P1bcheck Kit Dv0 9019Dv0 9021Dv0 9027 Cart Part No Dv0.900.01.0.Sp , Float Level Sensor Cart Part No Dv0.901.11.0.00 , Float Type Level Sensor Cart Part No Dv0.901.25.0.00 , Float Type Level Sensor Cart Part No Dv0.901.26.0.00 , Float Level Sensor 105 Len Cart Part No Dv0.901.29.0.00 , Wet Pm Kit (W/O Oil) - For Dv0.9018 Cart Part No Dv0.901.8.0.Sp , Pc Engine P1bcheck Kit Phase Ii Dv0 9026 Cart Part No Dv0.902.01.0.Sp , Float Type Level Sensorthreading1bspeffective Length 137 Mm Cart Part No Dv0.902.50.0.Pr , Pc Engineccheck Kitdv0 9019 9021 Cart Part No Dv0.903.01.0.Sp , Pc Engineccheck Kitdv0 9027 Cart Part No Dv0.904.01.0.Sp , Pc Engineccheck Kitdv0 9026 Cart Part No Dv0.905.01.0.Sp , Battery Cable Assembly70 Sq.Mm Cart Part No Dv0.907.10.0.00 , Engine Wiring Harness Assly: Dv0 Cart Part No Dv0.910.20.0.00 , Engine Wiring Harness Assembly With Kg545 Cart Part No Dv0.910.50.0.00 , Engine Wiring Harness Assembly:Dv10 Engine With Kg545 Unit & 4-20 Ma Gems Lop Se Cart Part No Dv0.910.60.0.00 , Engine Wiring Harness Sf Dv10 Engine Cart Part No Dv0.910.90.0.00 , Engine Control Panel To Alternator Control Harness Cart Part No Dv0.911.20.0.00 , Engine Control Panel To Alternator Control Harness Assemblyfor C T 3Phsu Cart Part No Dv0.911.40.0.00 , Engine Control Panel To Alternator Controlharness Assemblyfor C T3 Phsu Cart Part No Dv0.911.70.0.00 , Engine Wiring Harness With Dse 7320 Mkii Unit For Dv10 With Air Shutoff Valve Cart Part No Dv0.913.40.0.Pr , Engine Wiring Harness Assembly For Dv10 Enginewith Ncv Conduitt Cart Part No Dv0.918.70.0.Pr , Genset Panel To Remote Panel Harness Cart Part No Dv0.921.10.0.Pr , Engine Control Alternator C T Harness Cart Part No Dv0.921.20.0.Pr , Remote Panel To Railway Main Panel Harness Cart Part No Dv0.921.30.0.Pr , 3 3 K Ohm Parallel Resistor Module Cart Part No Dv0.921.70.0.Pr , Engine Wiring Harness Assembly For Dv10 Engine( With Ncv Conduitt ) Sf Isolatio Cart Part No Dv0.923.40.0.Pr , Liner Removing And Placing Tool Cart Part No Dv0.950.04.0.00 , Liner Pressing Mandrel Assembly Cart Part No Dv0.950.05.0.00 , Collet Fitting Tool Cart Part No Dv0.950.505.0.00 , Stem Seal Fitting Tool Cart Part No Dv0.950.506.0.00 , Injector Removing Tool Cart Part No Dv0.950.507.0.00 , Guide Stud For Crank Pulley Cart Part No Dv0.950.523.0.00 , Guide Stud For Flywheel Cart Part No Dv0.950.525.0.00 , Tool For Push Rod Spring Compression Cart Part No Dv0.950.530.0.00 , Guide Sleeve For Piston Insertion In To Liner For Dv Cart Part No Dv0.950.571.0.Tol , Guide Sleeve For Piston Insertion In To Liner For Crdi Cart Part No Dv0.950.572.0.Tol , Oil Seal Housing Alignment Toolflywheel End Side Dv0 950 69 0 00 Cart Part No Dv0.950.69.0.Tol , Oil Seal Housing Alignment Toolpulley End Side Dv0 950 70 0 00 Cart Part No Dv0.950.70.0.Tol , Oil Seal Pressing Tool For Pulley End Side For Dv Seriesdv0 950 72 0 00 Cart Part No Dv0.950.72.0.Tol , Plate Type Heat Exchanger (320-400Kva) Cart Part No Dv0.992.01.0.Pr , Turbo Compressor Pipe Out R H Cacside Cart Part No Dv0.992.28.0.Pr , Avr Sd-02 Cart Part No Dv0.998.01.0.Sp , Compounding Transformer Cart Part No Dv0.998.02.0.Sp , Variable Resistor Cart Part No Dv0.998.05.0.Sp , Relay K1 Cart Part No Dv0.998.08.0.Sp , Relay K2 Cart Part No Dv0.998.09.0.Sp , Varistor Cart Part No Dv0.998.11.0.Sp , Metring Ct Assembly Cart Part No Dv0.998.13.0.Sp , Diode Assembly Cart Part No Dv0.998.16.0.Sp , Metering Ct Neutral Cart Part No Dv0.998.17.0.Sp , Fuse F1 Cart Part No Dv0.998.19.0.Sp , Bridge Rectifier Diode Cart Part No Dv0.998.20.0.Sp , Contactor (K3) 24V Cart Part No Dv0.998.23.0.Sp , Fuse F2 Cart Part No Dv0.998.24.0.Sp , Pc Engine P1/B Check Kit - Dv0.9019, Dv0.9021, Dv0.9027 Woo Cart Part No Dv0.998.25.0.Sp , Pc Engine P1/B Check Kit Phase Ii - Dv0.9026 Woo Cart Part No Dv0.998.26.0.Sp , Pc Engine C Check Kit - Dv0.9019, Dv0.9021 Woo Cart Part No Dv0.998.27.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9027 Woo Cart Part No Dv0.998.28.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9026 Woo Cart Part No Dv0.998.29.0.Sp , Pc Engine Add On Kit Phase I Cart Part No Dv0.998.30.0.Sp , Pc Engine Add On Kitphase Ii Cart Part No Dv0.998.31.0.Sp , Dv0.998.36.* Cart Part No Dv0.998.36.0.Sp , Ct Assembly For Rdso 500Kva Vave (Suitable For Alternator) Cart Part No Dv0.998.51.0.Pr , Dv Service Timing Tool Cart Part No Dv0.999.01.0.Tol , Avr Excitation Unit Cart Part No Dv0.999.05.0.Sp , Compounding Transformer Cart Part No Dv0.999.07.0.Sp , Wet Pm Kit (W/O Oil ) For Dv0.9076 Cart Part No Dv0.999.102.0.Sp , Exciter Rotor Cart Part No Dv0.999.28.0.Sp , Exciter Stator Cart Part No Dv0.999.33.0.Sp , Centrifugal Filter Service Kit For Dv Cart Part No Dv0.999.40.0.00 , Motor 3Ph (Ie2 Type) V 415D (+/-10%), 50Hz(+/-5%), R/Min 1460, 22Kw, 30Hp, 42A, Cart Part No Dv0.999.40.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.1045... - Dv10 Cart Part No Dv0.999.71.0.Sp , Induction Motor5kw6 7 Hp 3 Phase50 Hz Cart Part No Dv0.999.73.0.Sp , Wet Pm Kit (W/O Oil) Fordv0.8107 - Dv10ta G1 Cart Part No Dv0.999.83.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9026... - Dv10ta G1 Cart Part No Dv0.999.84.0.Sp , Battery Tester Cart Part No Dv0.999.85.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.1002 - Dv10 Cart Part No Dv0.999.87.0.Sp , Radiator U Hose Cart Part No Dv0.999.88.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9013, Dv0.8101, Dv0.9009 - Dv10ta Cart Part No Dv0.999.89.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9019 - Dv10ta Cart Part No Dv0.999.90.0.Sp , Pc Engine P1/B Check Kit - Dv0.9019, Dv0.9021, Dv0.9027 Wo Cart Part No Dv0.999.91.0.Sp , Pc Engine P1/B Check Kit Phase Ii - Dv0.9026 Wo Cart Part No Dv0.999.92.0.Sp , Pc Engine C Check Kit - Dv0.9019, Dv0.9021 Wo Cart Part No Dv0.999.93.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9027 Wo Cart Part No Dv0.999.94.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9026 Wo Cart Part No Dv0.999.95.0.Sp , Pc Engine Tappet Setting Kit Cart Part No Dv0.999.96.0.Sp , Pc Engine Tappet Setting Kit Phase Ii Cart Part No Dv0.999.97.0.Sp , Dcuvd1cc01 Cart Part No Dv0.Egt4.01.0.Pr , Expansion Tank Cart Part No Dv0.M001.06.0.00 , Crankcase Assembly Cart Part No Dv2.001.30.0.00 , Cylinder Liner Assemblywith Abp Ring Cart Part No Dv2.002.20.0.Pr , Crankshaft Assly Without Gear Cart Part No Dv2.003.10.0.00 , Crank Pulley 200 Pcd & Spb Profile Cart Part No Dv2.003.13.0.00 , Extension Pulley For Fan Drive (Pcd 176) (6 Groove) Cart Part No Dv2.003.16.0.00 , Extension Pulley For Fan Drivepcd 176 6 Groove Cart Part No Dv2.003.18.0.Pr , Piston Assembly Cart Part No Dv2.006.10.0.Spr , Piston Ring Set Cart Part No Dv2.006.20.0.Spr , Nozzle Clampfinish Cart Part No Dv2.007.04.0.00 , Cylinder Head Sub Assembly With Valve Spring Valve For Cr Cart Part No Dv2.007.130.0.00 , Cylinder Head Assembly Complete For Cr Cart Part No Dv2.007.150.0.Pr , Oil Cooler17 Plate Pn Nj 57000For Dv Engine Cart Part No Dv2.014.06.0.00 , Filter Header Cart Part No Dv2.014.07.0.00 , Hose: Radiator To Suction Pipe Cart Part No Dv2.014.24.0.00 , Jointfor Cooler Cover Cart Part No Dv2.014.95.0.Pr , V Belt 2Jbx58 Pitch Length 1550 Cart Part No Dv2.016.02.0.00 , V Belt Spb Ar1250 (6 Nos. Set) Cart Part No Dv2.016.04.0.00 , V Belt Bx 1250 Ar Cart Part No Dv2.016.26.0.Pr , V-Belt-3Av15 X1275 Cart Part No Dv2.016.27.0.Pr , Lube Oil Sump Cart Part No Dv2.017.03.0.00 , Ecu Cart Part No Dv2.019.02.0.00 , High Pressure Pipe Assembly Cart Part No Dv2.021.130.0.00 , H.P Pipe (Cyl. No. 1 & 12) Cart Part No Dv2.021.31.0.00 , H P Pipecylno2 11 Cart Part No Dv2.021.32.0.00 , Hp Pipepump To Rail Lhs Cart Part No Dv2.021.38.0.Pr , Hp Pipepump To Rail Rhs Cart Part No Dv2.021.39.0.Pr , Clamp For Low Pressure Pipe (Dia 16) Cart Part No Dv2.021.58.0.00 , Rubber Sleeve (Dia 9) Cart Part No Dv2.021.59.0.00 , Hp Piperail To Fuel Pump Lhs Cart Part No Dv2.021.67.0.00 , Hp Piperail To Fuel Pump Rhs Cart Part No Dv2.021.68.0.00 , Rail Mtg Bracket Cart Part No Dv2.021.72.0.Pr , Hp Pipe Assemblyrouted For Cyl No4 10 Cart Part No Dv2.021.73.0.Pr , Hp Pipe Assemblyrouted For Cyl No5 11 Cart Part No Dv2.021.74.0.Pr , Hp Pipe Assemblyrouted For Cyl No6 12 Cart Part No Dv2.021.75.0.Pr , Hp Pipe Assemblyrouted For Cyl No7 Cart Part No Dv2.021.76.0.Pr , Hp Pipe Assemblypump To Rail Lhsfrom Few Cart Part No Dv2.021.77.0.Pr , Hp Pipe Assemblypump To Rail Rhs From Few Cart Part No Dv2.021.78.0.Pr , High Pressure Rail Right Bank Viewed From Pulley End Cart Part No Dv2.021.81.0.Pr , Fuel Pipefuel Pump To Main Filter Rh From Ge Cart Part No Dv2.022.103.0.00 , Rail Leak Off Pipe Assembly Cart Part No Dv2.022.106.0.00 , Fuel Pipepre Filter To Main Filter 1 Cart Part No Dv2.022.108.0.00 , Fuel Pipepre Filter To Main Filter 2 Cart Part No Dv2.022.109.0.00 , Fuel Pipe Assly Flexible Cart Part No Dv2.022.110.0.00 , Adaptorm16 To M18 Cart Part No Dv2.022.112.0.00 , Adaptor (M14 To M18) Cart Part No Dv2.022.113.0.00 , Deairazation Pipe Cart Part No Dv2.022.114.0.00 , Spigot (M22 To M18) Cart Part No Dv2.022.116.0.00 , Hosefor Fuel Pump Leak Off Cart Part No Dv2.022.117.0.00 , Common Head Leak Off Cart Part No Dv2.022.123.0.00 , Union Adaptorfor Head Leak Off Cart Part No Dv2.022.124.0.00 , Clamp For Fuel Pipe Cart Part No Dv2.022.125.0.Pr , Oil Supply Pipecrankcase To Fuel Pump In Cart Part No Dv2.022.126.0.00 , Low Pressure Pipe Clamp Pipe Dia 10 X 25 Crs Cart Part No Dv2.022.127.0.Pr , Adaptorm12xm16 Both End Male Cart Part No Dv2.022.142.0.00 , Filter To Pump Cart Part No Dv2.022.153.0.Pr , Fuel Pipe (Fuel Pump Leak Off Lh From Ge-1) Cart Part No Dv2.022.157.0.Pr , Pump Leak Off Cart Part No Dv2.022.159.0.Pr , Fuel Pipemain Filter To Fuel Pump Rh From Ge Cart Part No Dv2.022.165.0.00 , Fuel Pipemain Filter To Fuel Pump Lh From Ge Cart Part No Dv2.022.166.0.00 , Fuel Pipe (Fuel Pump Leak Off Rh From Ge) Cart Part No Dv2.022.167.0.00 , Fuel Pipefuel Pump Leak Off Lh From Ge Cart Part No Dv2.022.168.0.00 , Injector Leakoff Pipea Bank Cart Part No Dv2.022.172.0.Pr , Injector Leakoff Pipeb Bank Cart Part No Dv2.022.173.0.Pr , Fuel Pipeinjector Leakoff Pipe Cart Part No Dv2.022.174.0.Pr , Rail Leakoff Cart Part No Dv2.022.178.0.Pr , Leak Pipe Cart Part No Dv2.022.179.0.Pr , Fuel Pipepre Filter To Main Filter 1 Cart Part No Dv2.022.182.0.Pr , Fuel Pipepre Filter To Main Filter 2 Cart Part No Dv2.022.183.0.Pr , Fuel Pipemain Filter To Fuel Pump Rh From Ge Cart Part No Dv2.022.185.0.Pr , Adaptor For Pressure Sensor Cart Part No Dv2.022.66.0.00 , Adaptor For Pressure Sensor Cart Part No Dv2.022.66.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv2.022.71.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No Dv2.022.72.0.00 , Feed Pump Fuel In Pipe: Flex Cart Part No Dv2.022.73.0.00 , Fuel Pipe: Pump Leak Off: Flex Cart Part No Dv2.022.74.0.00 , Inlet Manifold Endr Hside Cart Part No Dv2.023.03.0.Pr , Dome Nut Cart Part No Dv2.023.06.0.Pr , Stud (185L) Cart Part No Dv2.023.07.0.Pr , Fan Pulley (185 Pcd & Spb Profile) Cart Part No Dv2.029.01.0.00 , Fan Pulley (3Groove, 222 Pcd) Cart Part No Dv2.029.04.0.00 , Special Studm12x1 75X142 L Cart Part No Dv2.029.07.0.00 , Fan Drive Assembly Cart Part No Dv2.029.120.0.00 , Fan Drive Assembly Cart Part No Dv2.029.220.0.Pr , Fan Drive Sub Assembly Cart Part No Dv2.029.230.0.Pr , Bracket For Fan Drive Arrangement Cart Part No Dv2.029.24.0.Pr , Pulley For Fan Drive Cart Part No Dv2.029.26.0.Pr , Fan Drive Assembly Cart Part No Dv2.029.30.0.00 , Spacer 50Mm For Dv12 Engine Cart Part No Dv2.029.71.0.00 , Fan Spacer Cart Part No Dv2.029.72.0.00 , Hose: Radiator To Engine Cart Part No Dv2.031.14.0.00 , Metalic Pipe From Thermo To Rad. Cart Part No Dv2.031.17.0.00 , Fan: 42 Dv12 Cart Part No Dv2.031.24.0.00 , 44 Fan For Dv12 With 45 Degblade Angle Cart Part No Dv2.031.25.0.00 , Pipe: Thermostat - Radiator Cart Part No Dv2.031.27.0.00 , Radiator Outlet Hose For Dv12e-750Kva Cart Part No Dv2.031.51.0.00 , 44Fan For Dv12 Cart Part No Dv2.031.56.0.00 , Radiator 750Kva Cart Part No Dv2.031.60.0.Pr , 42Fan For Dv2 Cart Part No Dv2.031.61.0.Pr , Heat Exchanger Pipe For Dv12 Cart Part No Dv2.031.65.0.00 , Radiator Inlet Pipe For Dv12e-750Kva Cart Part No Dv2.031.72.0.00 , Radiator Outlet Pipe For Dv12e-750Kva Cart Part No Dv2.031.74.0.00 , 44 Fan For Dv12export Cart Part No Dv2.031.86.0.Pr , Aluminium Radiator Assembly Cart Part No Dv2.031.87.0.Pr , Pipe From Thermostat To Radiator In Cart Part No Dv2.031.88.0.Pr , Rad Cac Hose Cart Part No Dv2.031.91.0.00 , Fan 58For 750Kva Cart Part No Dv2.031.94.0.Pr , Turbocharger (Left Bank From Fwe) Cart Part No Dv2.032.108.0.Pr , Turbocharger (Right Bank From Fwe) Cart Part No Dv2.032.109.0.Pr , Jointfor Flangefor T C Lub Oil Outlet Pipe Cart Part No Dv2.032.115.0.Pr , Jointbetbello Exh Manifold Cart Part No Dv2.032.14.0.Pr , Turbocharger: Dv12 750 Kva Engine Cart Part No Dv2.032.33.0.00 , Turbocharger For Dv12 750 Kva Engine - Right Bank(537819020896) Cart Part No Dv2.032.34.0.00 , Turbo Drain Pipe (Rh) (From Flywheel End) Cart Part No Dv2.032.37.0.00 , Turbo Drain Pipe Cart Part No Dv2.032.38.0.00 , Spacer I D 11Xo D 20X15l Cart Part No Dv2.032.41.0.00 , Turbo Drain Piperh From Flywheel End Cart Part No Dv2.032.43.0.Pr , Turbo Drain Pipelh From Flywheel End Cart Part No Dv2.032.44.0.Pr , Hose For Air Intak Adaptor Cart Part No Dv2.032.51.0.Pr , Left Bank Tcharger Cart Part No Dv2.032.97.0.00 , Right Bank Turbocharger Cart Part No Dv2.032.98.0.00 , Air Pipe (Dv2) From Turbo Compressor Out To Cac Cart Part No Dv2.033.03.0.00 , Cac Inlet Pip Cart Part No Dv2.033.06.0.00 , Cac Out Pipe Cart Part No Dv2.033.07.0.00 , Cac Pipe (Radiator Out) Cart Part No Dv2.033.101.0.Pr , Cac Piperadiator In Cart Part No Dv2.033.83.0.00 , O Ring: Cac Pipe Adaptor Cart Part No Dv2.033.85.0.00 , O Ringfor Cac Pipe Adaptor Cart Part No Dv2.033.86.0.Pr , Oringcac In Pipe Cart Part No Dv2.033.87.0.00 , Cam Shaft Cart Part No Dv2.040.03.0.00 , Cambox Type Fuel Pump Total Assydv2 Cart Part No Dv2.040.10.0.00 , Cambox Type Fuel Pump Total Assy (Dv2) Cart Part No Dv2.040.190.0.00 , Delivery Tube Cart Part No Dv2.042.10.0.00 , Delivery Tube Assembly Cart Part No Dv2.042.40.0.Pr , Breather Cart Part No Dv2.046.01.0.00 , Cartridge (Oil Separator) Cart Part No Dv2.046.02.0.00 , Injector Cart Part No Dv2.050.01.0.00 , Mechanical Injector With Side Fuel Entrysuitable For Mounting With Feedtube Cart Part No Dv2.050.13.0.Pr , Heat Shieldr H Cart Part No Dv2.051.16.0.00 , Heat Shieldl H Cart Part No Dv2.051.17.0.00 , Support Plate Cart Part No Dv2.051.20.0.00 , Heat Shieldr H Cart Part No Dv2.051.21.0.00 , Heat Shieldl H Cart Part No Dv2.051.22.0.00 , Heat Shieldrh Side End Mounted Cart Part No Dv2.051.23.0.00 , Breather Hose Breather To Breather Pipe Cart Part No Dv2.054.01.0.00 , Hose At Breather Side Cart Part No Dv2.054.92.0.00 , Breather Hose (From Pipe To Base Plate Cart Part No Dv2.054.93.0.00 , Oil Spray Nozzle Cart Part No Dv2.060.06.0.Pr , Crankcase Sub Assembly Cart Part No Dv2.060.180.0.Pr , Cable Type Anti Vibration Mounting Cart Part No Dv2.061.01.0.Pr , Anti Vibration Mount Engine Side Cart Part No Dv2.061.04.0.Pr , Rocker Box Cover (With Groove) Cart Part No Dv2.067.01.0.00 , Rocker Box: Clearance Cut Cart Part No Dv2.067.02.0.00 , O Ringfor Rocker Box Cover Cart Part No Dv2.067.03.0.Pr , Rocker Box Coverwith Groove Cart Part No Dv2.067.24.0.Pr , Rocker Box Cart Part No Dv2.067.25.0.Pr , Gasket (For Rocker Cover) Cart Part No Dv2.067.26.0.Pr , O Ring For Rocker Box Cart Part No Dv2.067.48.0.00 , Joint For Rocker Cover Cart Part No Dv2.067.49.0.00 , Breather Cart Part No Dv2.068.60.0.00 , Conical Copper Washer Cart Part No Dv2.069.07.0.00 , Oil Drain Pipe: Fip To Ccase Cart Part No Dv2.069.65.0.00 , Leak Off Pipe Cart Part No Dv2.069.85.0.00 , High Pressure Rail Left Bank Viewed From Pulley End Cart Part No Dv2.072.01.0.00 , High Pressure Rail For Right Bank Viewed From Pulley End Cart Part No Dv2.072.02.0.00 , High Pressure Cp3 3 Pump For Dv Engines Cart Part No Dv2.072.04.0.Pr , Mprop (Imv) For Cp3.3 Fip Cart Part No Dv2.072.10.0.Sp , Injector For Dv8ta 320 Kva Cpcb4 7 X 146 X 575K 1 3He 10 5 Cart Part No Dv2.072.171.0.Pr , Injector For Dv Series Cpcb4 7 X 146 X 850K 1 3He 10 5 Cart Part No Dv2.072.173.0.Pr , O Ring Between Gear Casing And Fuel Pump Cart Part No Dv2.072.24.0.Pr , Gear Casingfor Dv12 Crdi Cart Part No Dv2.072.25.0.Sp , Plate For Cam Sensor Location Cart Part No Dv2.072.57.0.00 , Cam Sensor Locator Cart Part No Dv2.072.58.0.00 , Bridge For Cam Sensor Cart Part No Dv2.072.69.0.00 , O Ring (For Cam Sensor Locator) Cart Part No Dv2.072.71.0.00 , Belleville Washer For Cam Sensor Cart Part No Dv2.072.77.0.00 , Inlet Connectorfeedtube Cart Part No Dv2.072.88.0.00 , Retaining Nut Cart Part No Dv2.072.89.0.00 , Injector For Dv Crdi Engine Cart Part No Dv2.072.92.0.00 , Tdc Sensor Wheel For Common Rail Cart Part No Dv2.076.01.0.Pr , Bracket For Fuel Filter Cart Part No Dv2.079.02.0.Pr , Bracket For Prefilter Cart Part No Dv2.079.04.0.Pr , Adaptor For Inlet Manifold2 Port Cart Part No Dv2.081.01.0.00 , Adaptor (M16xm22) Cart Part No Dv2.082.48.0.00 , Breather Housing (For Pipavav) Cart Part No Dv2.086.129.0.Pr , Joint Bet. Breather & Gear Casing (Pipavav) Cart Part No Dv2.086.132.0.00 , Air Side Cover Outlet (For Cac) Cart Part No Dv2.086.139.0.Pr , Rubber Sleeve For Fuel Pipe Cart Part No Dv2.086.156.0.00 , Clamp For Fuel Pipe Cart Part No Dv2.086.157.0.00 , Turbo Oil Drain Pipemarine Cart Part No Dv2.086.165.0.Pr , Turbo Oil Drain Pipe Cart Part No Dv2.086.202.0.Pr , Joint For Flywheel Housing Cart Part No Dv2.086.32.0.00 , Turbo Adaptorrh Cart Part No Dv2.086.37.0.00 , Turbo Oil Supply Pipe Rh Cart Part No Dv2.086.47.0.00 , Turbo Oil Supply Pipe(Lh) Cart Part No Dv2.086.48.0.00 , Hose For Turbo Compressor Out Cart Part No Dv2.086.52.0.00 , Plate For Thermostat (Marine) Cart Part No Dv2.086.78.0.00 , Joint For Cooler Cover (Lh) (From Fwe) Cart Part No Dv2.086.85.0.00 , Joint For Cooler Cover (Rh) (From Fwe) Cart Part No Dv2.086.86.0.00 , Joint (Between Cac & Turbo-Adaptor) Cart Part No Dv2.086.87.0.00 , Hosedia 48 Betsleeve Pipe Cart Part No Dv2.087.02.0.00 , Hosedia 54 Bet2 Pipes Cart Part No Dv2.087.03.0.00 , Breather Pipe Clampon Cac Cover Front Cart Part No Dv2.087.06.0.00 , Breather Pipe Clampon Gear Casing Cart Part No Dv2.087.07.0.00 , Clamp On Gearcasing Cart Part No Dv2.087.13.0.00 , Breather Pipe Cart Part No Dv2.087.15.0.Pr , Breather Pipe Dia 44 5Extended Cart Part No Dv2.087.16.0.Pr , Bracket For Breather Pipe Cart Part No Dv2.087.17.0.Pr , Cac For Domestic Application Cart Part No Dv2.087.46.0.Pr , Dcu Wiring Harness Sf Dv12 Cpcb Iv Engine Cart Part No Dv2.112.50.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Ivecu Chamber 1 Cart Part No Dv2.114.10.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 2 3 4 Cart Part No Dv2.114.20.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv2.114.30.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 8 Cart Part No Dv2.114.40.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Ivecu Chamber 1 Cart Part No Dv2.114.60.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv2.115.10.0.Pr , Silencer For Dv Series Cart Part No Dv2.188.10.0.00 , Silencer For Dv 500 - 750 Kva Cart Part No Dv2.188.80.0.00 , Bush -For Lifting Genset In Canopy -M20 X 2.5 X 35 Od Cart Part No Dv2.326.31.0.Pr , Metallic Pipe Engine To Egt (Rhs Side From F.W.E.) Cart Part No Dv2.477.08.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 1 Rhs Egt F W E Cart Part No Dv2.477.11.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Lhs Egt F W E Cart Part No Dv2.477.14.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.477.16.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Rhs Egt F W E Cart Part No Dv2.477.19.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Lhs Egt F.W.E.) Cart Part No Dv2.477.21.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Lhs Egt F.W.E.) Cart Part No Dv2.477.31.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Rhs Egt F W E Cart Part No Dv2.477.74.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-2) (Rhs Egt F.W.E.) Cart Part No Dv2.477.76.0.Pr , Metallic Pipe Engine To Egt (Lhs Side From F.W.E.) Cart Part No Dv2.477.77.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Lhs Egt F.W.E.) Cart Part No Dv2.477.78.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.477.79.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Lhs Tank Side Cart Part No Dv2.477.83.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Lhs Tank Side Cart Part No Dv2.477.84.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Lhs Tank Side Cart Part No Dv2.477.86.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Lhs Tank Side Cart Part No Dv2.477.88.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv2.477.89.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Rhs Tank Side Cart Part No Dv2.477.92.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Rhs Tank Side Cart Part No Dv2.477.93.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Rhs Tank Side Cart Part No Dv2.477.94.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Rhs Tank Side Cart Part No Dv2.477.96.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Rhs Tank Side Cart Part No Dv2.477.97.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Rhs Tank Side Cart Part No Dv2.477.98.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv2.477.99.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-1) (Lhs Egt F.W.E.) Cart Part No Dv2.478.02.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Rhs Egt F W E Cart Part No Dv2.478.04.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) (Rhs Egt F.W.E.) Cart Part No Dv2.478.21.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.478.23.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-4) (Rhs Egt F.W.E.) Cart Part No Dv2.478.24.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Lhs Egt F W E Cart Part No Dv2.478.26.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 3 Lhs Egt F W E Cart Part No Dv2.478.28.0.Pr , Copper Radiator Assembly Cart Part No Dv2.486.10.0.Pr , Hose Reducer Elbow For 600Kva Genset Cart Part No Dv2.505.01.0.00 , Hose Reducer Elbow Cart Part No Dv2.505.02.0.00 , Hose From Pipe To Turbocharger Cart Part No Dv2.505.07.0.00 , Air Cleaner Lh Side Cart Part No Dv2.505.10.0.00 , Metalic Pipe For Dv12 Cart Part No Dv2.505.16.0.00 , Air Cleaner Kit Cart Part No Dv2.505.50.0.00 , Air Cleaner Kit Cart Part No Dv2.505.60.0.00 , Air Cleaner Hosebetween Pipe And Air Cleaner Cart Part No Dv2.505.86.0.Pr , Elbow Hose Cart Part No Dv2.506.01.0.00 , Hose Clamp Cart Part No Dv2.506.03.0.00 , Pre Cleaner Metal Cart Part No Dv2.506.10.0.00 , Air Cleaner Assly. Cart Part No Dv2.506.60.0.00 , Air Filter Safety Cart Part No Dv2.506.62.0.00 , Air Filter Primary Cart Part No Dv2.506.63.0.00 , Fuel Pipe Tank To Leak Off Pipe Cart Part No Dv2.507.02.0.00 , Fuel Pipe: Fuel Tank To Fuel Prefilter Cart Part No Dv2.507.03.0.00 , Fuel Pipe Return Cart Part No Dv2.507.15.0.00 , Fuel Pipe ( Return ) For 750 Kva Cart Part No Dv2.507.22.0.00 , Fuel Inlet Pipe (From Tank To Pre-Filter)Straight Cart Part No Dv2.507.23.0.00 , Fuel Inlet Pipe (From Tank To Pre-Filter)Bend Cart Part No Dv2.507.24.0.00 , Fuel Pipes From Tank To Prefilter Cart Part No Dv2.507.26.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No Dv2.507.27.0.Pr , Fuel Return Pipem16x1 5 Male Plug And M22x1 5 Union Nut Cart Part No Dv2.507.32.0.Pr , Fuel Inlet Pipe From Tank To Pre Filterm22x1 5 Union Nut And M22x1 5 Banjo Cart Part No Dv2.507.33.0.Pr , Koel Green Alternatorkg 750 S T Framel Kg 49 1 M75sae 1 14415V50hz0 8P F750 H H Cart Part No Dv2.701.05.0.Pr , 25Afuse Cart Part No Dv2.710.02.0.Pr , 40Afuse Cart Part No Dv2.710.03.0.Pr , 80Afuse Cart Part No Dv2.710.05.0.Pr , 30Afuse Cart Part No Dv2.710.11.0.Pr , Koel Green Alternatorkg 625 S T Framel Kg 47 E1sae 1 14 415V50 Hz0 8 Pf Cart Part No Dv2.801.35.0.Pr , Rain Cap Assembly For Exhaust Bend Cart Part No Dv2.806.23.0.00 , Tail Pipe Cart Part No Dv2.806.25.0.00 , Exhaust Bend Cart Part No Dv2.806.65.0.Pr , Engine Mtg Foot For 750 Kva Baseframe Cart Part No Dv2.850.51.0.00 , 4 Pin Connector (Female Conector Male Pins) Cart Part No Dv2.852.28.0.00 , Assembly For Rmsremote Monitoring Systemunit For Kg934 Cart Part No Dv2.858.12.0.00 , Assembly For Krm Unit For Kg541 With Package Cart Part No Dv2.858.14.0.Pr , Assembly For Krm Unit For Kg745 With Package Cart Part No Dv2.858.27.0.Pr , Assembly For Krm Unit For Kg645 With Package Cart Part No Dv2.858.29.0.Pr , Krms Device Sf Rdso Projectforkg745 Unit With 2 Years Data Package Inclusiv Cart Part No Dv2.858.31.0.Pr , Assembly For Krm Unit For Kg645c With Package Cart Part No Dv2.858.39.0.Pr , Krm Unit With Package For Kg745(With Cpcb4) Rs232 With Package Cart Part No Dv2.858.49.0.Pr , Assembly For Rmsremote Monitoring Systemunit Cart Part No Dv2.858.80.0.00 , Protocol Rs485 To Snmp Convertor Module Cart Part No Dv2.858.85.0.Pr , Push Button Cart Part No Dv2.860.48.0.00 , 1600A 4P Acb ( Edo ) Type-3Wj1116-2Af62-4Dh0- Z T40+ F40 Cart Part No Dv2.863.77.0.00 , Motorised Mccb Compact 36 Ka At 415 Vac, Nsx250n, & 4P, 250A, Cart Part No Dv2.863.79.0.00 , Motor Mechanism, Mt 250, Compact Nsx250, Powerpact Multi Standard L, Cart Part No Dv2.863.81.0.00 , Mccb 1 Aux.Switch Cart Part No Dv2.863.82.0.00 , Motorised Mccb Compact 36Ka At 415 Vac, Micrologic 2.3 Trip Unit Nsx400f, Cart Part No Dv2.863.85.0.00 , Motor Mechanism, Mt 400-630, Compact Nsx400/630, Powerpact Multistandard L, 220 Cart Part No Dv2.863.86.0.00 , Earthing Cable Panel To Base Plate For 600Kva Cart Part No Dv2.866.01.0.00 , Rra Assembly Kg49 1 Kva Ratings 625 To 750 Kva 3Ph Cart Part No Dv2.901.01.0.Asp , Fan-Kg49.1,Kva Rating-625 To 750Kva,3Ph Cart Part No Dv2.901.04.0.Asp , Varister-Kg49.1,Kva Rating-625 To 750Kva,3Ph. Cart Part No Dv2.901.05.0.Asp , Coupling Disckg49 1 Kva Rating 625 To 750Kva 3Ph Cart Part No Dv2.901.12.0.Asp , Set Of 3 Ct 1000/5 Ls Frame - Kg 47.2 Cart Part No Dv2.901.14.0.Asp , Ex. Rotor With Rra Frame 38 8P Cart Part No Dv2.901.22.0.00 , Fan Assembly Pdc Kg 38 Cart Part No Dv2.901.23.0.00 , Coolant Level Switchlow High Level With Led Cart Part No Dv2.901.26.0.00 , Kit Pd500 For Eco 38 Aairgap 0.4 Cart Part No Dv2.901.37.0.00 , Diode Assembly Kg44 3 Cart Part No Dv2.901.57.0.00 , Coupling Disc Kg44.3 Cart Part No Dv2.901.59.0.00 , Coupling Disc Set Sae 11.5 Kg 42.3 Cart Part No Dv2.901.63.0.00 , Diode Bridge Rectifier Kg40 Cart Part No Dv2.901.64.0.00 , Rra Assembly Kg 47.2 Cart Part No Dv2.901.65.0.00 , Varister Kg47.2 Cart Part No Dv2.901.90.0.00 , Adaptor For Pressure Sensor Cart Part No Dv2.903.03.0.00 , Adaptor For Gems Lop Sensor Cart Part No Dv2.903.06.0.00 , Clamps Cart Part No Dv2.903.16.0.Pr , Clamps Cart Part No Dv2.903.17.0.Pr , Wiring Harness From Engine Control Panel To Alternator Terminal Box With Ct S Cart Part No Dv2.903.30.0.00 , Crank Speed Hall Effect Sensor Cart Part No Dv2.903.31.0.00 , Cam Speed Hall Effect Sensor Cart Part No Dv2.903.32.0.00 , Insulatorm6 X 25Mmlength Cart Part No Dv2.903.36.0.Pr , Insulator For Ecuorder Number 20A F M6 30Mm Cart Part No Dv2.903.46.0.Pr , Clamp For Injector Connector Cart Part No Dv2.903.77.0.Pr , Special Black Tie For Crdi Cart Part No Dv2.903.78.0.00 , Resting Plate For Ecu Cart Part No Dv2.904.35.0.Pr , Ecu Mounting Plate Cart Part No Dv2.904.36.0.Pr , Support Bracket For Resting Plate Cart Part No Dv2.904.37.0.Pr , Support Bracket For Resting Plate Cart Part No Dv2.904.38.0.Pr , Ecu Mounting Support Channel Cart Part No Dv2.904.39.0.Pr , Cable Gland Assembly For Dv Engine Cart Part No Dv2.906.10.0.00 , Wiring Harnessfrom Interface Card To Control Panel For Dv12 Cart Part No Dv2.906.20.0.Pr , Wiring Harness From Interface Relay Box To Master Ecu For Dv12 Cart Part No Dv2.906.30.0.Pr , Wiring Harness From Interface Relay Box To Slave Ecu For Dv12 Cart Part No Dv2.906.40.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection For Dv12 Cart Part No Dv2.906.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection For Dv12 Cart Part No Dv2.906.60.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection With Pump F Cart Part No Dv2.906.70.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection With Pump Fo Cart Part No Dv2.906.80.0.Pr , Control Panel For Dv12 750Kva Crdi Genset Cart Part No Dv2.906.90.0.Pr , Battery Cable Assembly70 Sq Mm With Suitable Lug Cart Part No Dv2.908.40.0.00 , Wiring Harness From Master Ecu To Sensor Cart Part No Dv2.909.50.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No Dv2.909.60.0.Pr , Engine Wiring Harness Assemblyfor Dv12 Engine With Kg545 Unit 4 20 Ma Gems Lo Cart Part No Dv2.910.50.0.00 , Engine Wiring Harness Assembly & 4-20 Ma Cart Part No Dv2.910.60.0.00 , Engine Wiring Harness Assemblyfor Dv12 Engine & 4-20 Ma Gems Lop Sensor Cart Part No Dv2.910.70.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection Cart Part No Dv2.911.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection Cart Part No Dv2.911.60.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset 2 Cart Part No Dv2.913.95.0.Pr , Crdi Interface Card Cart Part No Dv2.989.24.0.00 , Joint For Raw Water Pipe Assembly (120 Od X 60 Id X 95 Pcd) Cart Part No Dv2.993.23.0.00 , Crdi Can Cable Genset Panel To Pc Cart Part No Dv2.999.01.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9101... - Dv12eta G11 Cart Part No Dv2.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.1246, Dv2.8301, Dv2.1045 - Dv12 Sr1 Cart Part No Dv2.999.62.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.8304 - Dv12ta Cart Part No Dv2.999.63.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9104 - Dv12eta G11 Cart Part No Dv2.999.64.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.8309 - Dv12ta G2 Cart Part No Dv2.999.65.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9205 Cart Part No Dv2.999.66.0.Sp , Wet Pm Kit (W/O Oil ) For Dv2.9110 Cart Part No Dv2.999.72.0.Sp , Wet Pm Kit (W/O Oil ) For Dv2.8311 Cart Part No Dv2.999.73.0.Sp , Dc2 Controller For Dv12 Engine Cart Part No Dv2.M002.02.0.00 , Clamp For Pipeo D 22 Cart Part No Dv2.W022.27.0.Pr , V Band Clampdia 104 Cart Part No Dv2.W032.21.0.Pr , O Ring For Heat Exchanger Cart Part No Dv2.W055.02.0.Pr , Crankcase Sub Assly. Cart Part No Dv8.001.10.0.00 , Crankcase Sub Assly Cart Part No Dv8.001.240.0.Pr , Crankshaft (Sub Assly) Cart Part No Dv8.003.10.0.00 , Crankshaft Gear Cart Part No Dv8.003.13.0.Pr , Cam Gearfinish Cart Part No Dv8.004.03.0.Pr , Cam Shaft & Gear Assembly Cart Part No Dv8.004.94.0.00 , Piston Assembly Kit Dv8 Cart Part No Dv8.006.04.0.Sp , Bridge For Rocker Lever Cart Part No Dv8.007.14.0.Pr , Bridge For Rocker Lever Cart Part No Dv8.007.18.0.00 , Bridge For Rocker Lever Cart Part No Dv8.007.18.0.Pr , Double Gear Assembly Cart Part No Dv8.010.70.0.Pr , Sub Assly Of Intermediate Gear Bush Cart Part No Dv8.011.10.0.Pr , Driving Gear Lop Cart Part No Dv8.013.06.0.00 , Pipe Thermostat To Radiator In Cart Part No Dv8.014.21.0.00 , Hose (Radiator To Engine) Cart Part No Dv8.014.22.0.00 , Lube Oil Sump Cart Part No Dv8.017.03.0.00 , Fabricated Sump Cart Part No Dv8.017.24.0.Pr , Fuel Pump Gearfinish Cart Part No Dv8.019.03.0.Pr , High Pressure Pipe Assembly Cart Part No Dv8.021.130.0.00 , Balancing Pipe Assemblyfor Rail Cart Part No Dv8.021.440.0.Pr , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.101.0.00 , Fuel Pipe (Tank To Feed Pump In) Cart Part No Dv8.022.103.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv8.022.104.0.00 , Fuel Pipe For Filter To Pump (Flexible) Cart Part No Dv8.022.105.0.00 , Fuel Pipe For Feed Pump To Filter (Flexible) Cart Part No Dv8.022.106.0.00 , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.114.0.Pr , Fuel Pipefuel Filter To Fuel Pump Cart Part No Dv8.022.115.0.Pr , Fuel Pipemain Filter To Fuel Pump Lh From Ge Cart Part No Dv8.022.129.0.Pr , Fuel Pipe (Fuel Pump Leak Off Lh From Ge) Cart Part No Dv8.022.132.0.Pr , Leak Off Pipeabanklh From Ge Cart Part No Dv8.022.136.0.Pr , Leak Off Pipebbankrh From Ge Cart Part No Dv8.022.137.0.Pr , Leak Off Pipe (End Connection) Cart Part No Dv8.022.138.0.Pr , Fuel Pipe (Rail Leak Off) Cart Part No Dv8.022.139.0.Pr , Fuel Pipe Assly Cart Part No Dv8.022.140.0.00 , Fuel Pipe Pri Filter To Main Filter Cart Part No Dv8.022.152.0.Pr , Leak Off Pipe B Bank Cart Part No Dv8.022.155.0.Pr , Leak Off Pipe A Bank Cart Part No Dv8.022.156.0.Pr , Leak Off Pipe (End Connection) Cart Part No Dv8.022.157.0.Pr , Fuel Pipe Assembly Cart Part No Dv8.022.160.0.00 , Hose (250 Mm For Dv8 Power Car ) Cart Part No Dv8.022.164.0.Pr , Fuel Pipe Assemblyflexible Cart Part No Dv8.022.170.0.Pr , Adaptor (M14*1.5 & M16*1.5) Cart Part No Dv8.022.41.0.00 , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.68.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv8.022.71.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No Dv8.022.72.0.00 , Feed Pump Fuel In Pipe (Flex) Cart Part No Dv8.022.73.0.00 , Fuel Pipe: Pump Leak Off (Flex) Cart Part No Dv8.022.74.0.00 , Fuel Pipe For Main Filter Leakoff Cart Part No Dv8.022.78.0.Pr , Clamp Cart Part No Dv8.022.79.0.Pr , Air Pipe Clamp (Bottom) Cart Part No Dv8.023.18.0.Pr , Adaptor (For Heater Tothrottle Body) Cart Part No Dv8.023.23.0.Pr , Adaptor For Inlet Manifold (2 Port) Cart Part No Dv8.023.24.0.Pr , Jointbetween Throttle Valve And Heater Cart Part No Dv8.023.26.0.Pr , Air Pipe Clamp Cart Part No Dv8.023.31.0.Pr , Exhaust Manifold (L.H. 2 Port ) Cart Part No Dv8.024.14.0.00 , Exhaust Manifold (R.H. 2 Port ) Cart Part No Dv8.024.15.0.00 , Support: Exhaust Elbow Lh Side Cart Part No Dv8.024.21.0.00 , Support: Exhaust Elbow Rh Side Cart Part No Dv8.024.22.0.00 , Fan Drive Assembly Cart Part No Dv8.029.165.0.00 , Fan Drive Asm Cart Part No Dv8.029.30.0.00 , Radiator Water Out Hose Cart Part No Dv8.031.04.0.00 , Silicon Hose 3.5 Id Cart Part No Dv8.031.05.0.00 , Clamp Assembly For Thermostat To Rad. In Pipe Cart Part No Dv8.031.91.0.Pr , Y-Shape Gas Connection Pipe Cart Part No Dv8.031.92.0.Pr , Breather Hose Cart Part No Dv8.031.96.0.Pr , Bracket For Turbo Adaptor Rh From Gear End Cart Part No Dv8.032.05.0.00 , Turbo Adaptorr Hfrom F Wend Cart Part No Dv8.032.18.0.00 , Turbocharger For Dv8,320 Kva Engine-A Bank Cart Part No Dv8.032.21.0.00 , Turbocharger For Dv8 Cart Part No Dv8.032.22.0.00 , Left Bank Tcharger Cart Part No Dv8.032.31.0.00 , Right Bank Turbocharger Cart Part No Dv8.032.32.0.00 , Turbo Adaptorlh From G E Cart Part No Dv8.032.33.0.00 , Spacer: Turbo Adaptor Cart Part No Dv8.032.34.0.00 , B/W Turbo Charger & Diffuser Cart Part No Dv8.032.57.0.Pr , Turbocharger Assly (R.H. From Ge) Cart Part No Dv8.032.72.0.Pr , Turbocharger Assly (L.H. From Ge) Cart Part No Dv8.032.73.0.Pr , Hose( For Air Inlet Adaptor ) Cart Part No Dv8.032.75.0.Pr , Air Pipe From Turbo Compressor Out To Cac Cart Part No Dv8.033.03.0.00 , Exhaust Elbow Cart Part No Dv8.033.04.0.00 , Gasket (For Cac Pipe ) Cart Part No Dv8.033.108.0.Pr , Rubber Bush (For Cacpipe) Cart Part No Dv8.033.109.0.Pr , V Band Clamp 77Mm Nom Dia Cart Part No Dv8.033.32.0.00 , Turbo Compressor Out Pipe (Lhview From Fwe) Cart Part No Dv8.033.34.0.00 , Turbo Compressor Out Pipe (Rhview From Fwe) Cart Part No Dv8.033.35.0.00 , Turbo Compressor Cart Part No Dv8.033.36.0.00 , Turbo Compressor Cart Part No Dv8.033.37.0.00 , V Band Clamp76 2Mm Nom Dia Cart Part No Dv8.033.38.0.Pr , Cac Pipe Cart Part No Dv8.033.43.0.00 , Cac Out Pipe Cart Part No Dv8.033.44.0.00 , Expansion Bellow 110 Id Cart Part No Dv8.033.45.0.Pr , V Band Clamp Cart Part No Dv8.033.67.0.Pr , Cac Pipe For Dv8 Engine Cart Part No Dv8.033.86.0.Pr , Hose: Radiator To Engine Cart Part No Dv8.035.04.0.00 , Pipe Thermostat To Rad In Cart Part No Dv8.035.05.0.00 , Suction Pipe: Radiator To Engine Cart Part No Dv8.035.20.0.00 , Hose Turbo To Pipe Cart Part No Dv8.035.33.0.00 , Copper Radiator Assembly Cart Part No Dv8.035.75.0.Pr , Pipe Thermostat To Rad In Cart Part No Dv8.035.77.0.Pr , Aluminium Radiator Assy Cart Part No Dv8.036.10.0.00 , Camshaft(For Pf33(N) Fuel Pump Cart Part No Dv8.040.03.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.10.0.00 , Rack Control Rod For Fuel Pump Cart Part No Dv8.040.19.0.00 , Pump With Dual Helix Element Cart Part No Dv8.040.22.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.220.0.00 , Fuel Filter & Water Seperator Cart Part No Dv8.040.23.0.00 , Spinon Fuel Filter Assly Cart Part No Dv8.040.24.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.250.0.00 , Water Separator Filter Remover Racor Bowl Wrench Cart Part No Dv8.040.33.01.Tol , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.430.0.00 , Sub Assly Of Delivery Tube Cart Part No Dv8.042.10.0.00 , Breather Hose Cart Part No Dv8.050.05.0.00 , Heat Shield (R.H) Cart Part No Dv8.051.03.0.00 , Center Bracket (For Heat Shield(R.H) ) Cart Part No Dv8.051.06.0.00 , Heat Shield (L.H) Cart Part No Dv8.051.07.0.00 , Bracket (For Heat Shield G.E. (L.H) ) Cart Part No Dv8.051.11.0.00 , Heat Shield (R.H. (For Modified Exhaust Manifold Cart Part No Dv8.051.14.0.00 , Heat Shield L H For Modified Exhaust Manifold Cart Part No Dv8.051.15.0.00 , Laggingfor Dv8 Diffuser Lhs From Few Cart Part No Dv8.051.42.0.Pr , Laggingfor Dv8 Diffuser Rhs From Few Cart Part No Dv8.051.43.0.Pr , Lagging For Turbo Adaptorrhs From Few Cart Part No Dv8.051.44.0.Pr , Lagging For Turbo Adaptorlhs From Few Cart Part No Dv8.051.45.0.Pr , Lower Heat Shield Rh From Fwe Cart Part No Dv8.051.53.0.Pr , Lower Heat Shield Lh From Fwe Cart Part No Dv8.051.55.0.Pr , Fan: 36 Plastic Cart Part No Dv8.052.01.0.00 , Fan Cart Part No Dv8.052.06.0.00 , Spacer ( 175Mm) For Dv8 Fan Cart Part No Dv8.053.03.0.00 , Fan Spacer 125Mm Length Cart Part No Dv8.053.05.0.00 , Breather Hose (From Pipe To Base Plate) Rh Side From F.W.E Cart Part No Dv8.054.11.0.Pr , Breather Hose (From Pipe To Base Plate) Lh Side From F.W.E Cart Part No Dv8.054.12.0.Pr , Joint: Turbo Outlet Cart Part No Dv8.064.01.0.00 , Oil Drain Pipe: Fip-Ccase Cart Part No Dv8.069.65.0.00 , Leak Off Pipe Cart Part No Dv8.069.85.0.00 , Fuel Filter For Common Rail Cart Part No Dv8.072.01.0.00 , 50 Hrs - A Check Maintenance Kit Cart Part No Dv8.072.02.0.Sp , Intermediate Gear Support Cart Part No Dv8.072.107.0.00 , Final Filter Cartridge Cart Part No Dv8.072.108.0.00 , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv8.072.12.0.Sp , Final Filter With Lift Pump For Dv Crdi Project17 Psi Pressure Regulator Cart Part No Dv8.072.121.0.Pr , Final Filter With Lift Pump For Dv Crdi Project8 Psi Pressure Regulator Cart Part No Dv8.072.122.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No Dv8.072.125.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv8.072.13.0.Sp , Sub Assly Of Intgear Bush Cart Part No Dv8.072.150.0.Pr , Joint: Gear Casing Cart Part No Dv8.072.27.0.00 , Joint For Gear Casing Cover Cart Part No Dv8.072.28.0.00 , Joint Forfuel Pump Cart Part No Dv8.072.48.0.00 , Nut (M18x1.5) (Hard Nut) Cart Part No Dv8.072.88.0.00 , Retainer Plate For Cr Intgear Support Cart Part No Dv8.072.92.0.00 , Retainer Plate For Cr Double Gear Support Cart Part No Dv8.072.94.0.00 , Fan Clutch Asembly For Dv8 Cart Part No Dv8.076.10.0.Pr , Tdc Sensor Wheel For Common Rail Cart Part No Dv8.081.01.0.Pr , Flywheel Assembly Cart Part No Dv8.081.10.0.Pr , Woodward Pg Plus System For 8 Cylinder Natural Gas Engine Cart Part No Dv8.087.100.0.Pr , Throttle Body L Series 50Mm Cart Part No Dv8.087.50.0.Pr , Expansion Bellowfor Exhmanifold Cart Part No Dv8.088.22.0.Pr , External Exhaust Manifold Lagging For Dv8 Cart Part No Dv8.088.26.0.Pr , Jointbet Exh Maniand Adaptor Cart Part No Dv8.088.31.0.Pr , Gas Train Assembly For Dv8 Ta Png Cart Part No Dv8.088.50.0.Pr , Wiring Harness Boxlh Side Cart Part No Dv8.099.130.0.Pr , Wiring Harness Boxrh Side Cart Part No Dv8.099.140.0.Pr , Dcu Wiring Harness Sf Dv8 Cpcb Iv Cart Part No Dv8.112.50.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 1 Cart Part No Dv8.114.10.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv8.114.30.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 8 Cart Part No Dv8.114.40.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv8.114.50.0.Pr , Engine Wiring Harness Sf Dv8 Engine Ecu Chember 1 For Cpcb Iv Cart Part No Dv8.114.60.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5,6,7 Engine A Cart Part No Dv8.115.10.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5,6,7 Engine B Cart Part No Dv8.115.20.0.Pr , Canopy Wiring Harness Sf 500X2 Optiprime Split Canopy Project Cart Part No Dv8.115.40.0.Pr , Flange Heater 24V 2Kw For Dv Series Cart Part No Dv8.1172.02.0.00 , Engine Plug Heater For Dv Series Cart Part No Dv8.1172.03.0.Pr , Flange For Bellow Cart Part No Dv8.188.05.0.00 , Silencer Cart Part No Dv8.188.10.0.00 , Adaptor M14 X M10 Cart Part No Dv8.235.01.0.Pr , Raw Water Pipecac Out To H E Cart Part No Dv8.301.08.0.Pr , Raw Water Pipeon He Inlet Cart Part No Dv8.301.17.0.Pr , Raw Water Pipecac Out To H E Cart Part No Dv8.301.18.0.Pr , Hose For Air Cleaner Cart Part No Dv8.303.04.0.00 , Hose For Air Cleaner Cart Part No Dv8.303.07.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Rhs Egt F W E Cart Part No Dv8.478.02.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.03.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Rhs Egt F.W.E.) Cart Part No Dv8.478.04.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-4) (Rhs Egt F.W.E.) Cart Part No Dv8.478.05.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Lhs Egt F W E Cart Part No Dv8.478.07.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) (Lhs Egt F.W.E.) Cart Part No Dv8.478.08.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Lhs Egt F W E Cart Part No Dv8.478.09.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Rhs Egt F.W.E.) Cart Part No Dv8.478.13.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.14.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Lhs Egt F.W.E.) Cart Part No Dv8.478.17.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Rhs Egt F W E Cart Part No Dv8.478.25.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Lhs Egt F.W.E.) Cart Part No Dv8.478.28.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Lhs Tank Side Cart Part No Dv8.478.31.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Lhs Tank Side Cart Part No Dv8.478.32.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 3Lhs Tank Side Cart Part No Dv8.478.33.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Lhs Tank Side Cart Part No Dv8.478.35.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.36.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.37.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Rhs Tank Side Cart Part No Dv8.478.39.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Rhs Tank Side Cart Part No Dv8.478.41.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Rhs Tank Side Cart Part No Dv8.478.42.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Rhs Tank Side Cart Part No Dv8.478.44.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.45.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.46.0.Pr , Metallic Pipe Engine To Egtrhs Side From F W E Cart Part No Dv8.478.47.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 1 Cart Part No Dv8.478.48.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Lhs Egt F W E Cart Part No Dv8.478.53.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Lhs Egt F W E Cart Part No Dv8.478.54.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Rhs Egt F W E Cart Part No Dv8.478.56.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Rhs Egt F W E Cart Part No Dv8.478.57.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Rhs Egt F W E Cart Part No Dv8.478.58.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Lhs Egt F W E Cart Part No Dv8.478.59.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Rhs Tank Side Cart Part No Dv8.478.62.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.63.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.64.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Lhs Tank Side Cart Part No Dv8.478.66.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.84.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Lhs Egt F W E Cart Part No Dv8.478.86.0.Pr , Hose For Dv8 Air Cleaner Cart Part No Dv8.505.04.0.00 , Hose For Dv8 At Turbo End 8240405 Cart Part No Dv8.505.08.0.00 , Hose Between Air Cleaner Pipe Cart Part No Dv8.505.28.0.Pr , Air Cleaner Kit Cart Part No Dv8.505.30.0.00 , Hose: Air Cleaner Cart Part No Dv8.505.71.0.00 , Rain Cap Clamp Cart Part No Dv8.505.72.0.00 , Air Cleaner Primary Element Cart Part No Dv8.505.74.0.00 , Air Cleaner Safety Element Cart Part No Dv8.505.75.0.00 , Hose: Air Cleaner Cart Part No Dv8.505.76.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No Dv8.505.80.0.00 , Fuel Pipe: Fuel Tank To Leak Off Pipe Cart Part No Dv8.507.02.0.00 , Fuel Pipe: Fuel Tank To Fuel Filter Cart Part No Dv8.507.03.0.00 , Fuel Inlet Pipe Cart Part No Dv8.507.06.0.00 , Fuel Pipe From Pre Filter To Tank Cart Part No Dv8.507.22.0.Pr , Fuel Pipe Cart Part No Dv8.507.23.0.Pr , Fuel Return Pipe M16x1 5 To M22x1 5 Cart Part No Dv8.507.24.0.Pr , Fuel Return Pipe (M16x1.5 Male Plug And M22x1.5 Union Nut) Cart Part No Dv8.507.26.0.Pr , Vent Pipem14 X1 5 Union Nut Both Side Cart Part No Dv8.560.01.0.Pr , Koel Green Alternatorkg400 S T Framel Kg 47 2 Vs3sae 1 14 415V50 Hz Cart Part No Dv8.801.21.0.00 , Koel Green Ls Ag316294 Alternator 320Kva Kg45c Sae 1 14 415V 50Hz Cart Part No Dv8.801.24.0.Pr , Koel Green Alternator Kg320 St Frame Mkg38 2 5L4asae 1 14 415V50hz0 8 Pf Cart Part No Dv8.801.25.0.Pr , Koel Green Alternator, Kg 380 Ss, Framekg 47.2 Vs2 Sae1/14, 415V, 50Hz Cart Part No Dv8.801.32.0.00 , Level Tube With Switch Cart Part No Dv8.803.114.0.Pr , Adblue Pipe 1 Supply Module To Dosing Module Bank A Cart Part No Dv8.803.154.0.Pr , Adblue Pipe 2 Supply Module To Dosing Module Bank A B Cart Part No Dv8.803.155.0.Pr , Adblue Pipe 3 Supply Module To Dosing Module Bank A Cart Part No Dv8.803.156.0.Pr , Adblue Pipe 1 Supply Module To Dosing Module Bank B Cart Part No Dv8.803.159.0.Pr , Adblue Pipe 3 Supply Module To Dosing Module Bank B Cart Part No Dv8.803.160.0.Pr , Adblue Day Tank Cart Part No Dv8.803.185.0.Pr , Adblue Piping Assy Day Tank Inlet Cart Part No Dv8.803.187.0.Pr , Fuel Flow Meter (Differential) For Rdso Dv8 500Kva Cpcb Iv+ Cart Part No Dv8.803.21.0.Pr , Isolation Valve Assyfor Adblue Day Tank Out Cart Part No Dv8.803.222.0.Pr , Flexible Hosesuitable For Adblue 32Aus Cart Part No Dv8.803.223.0.Pr , Mechanical Level Tubefor Adblue Cart Part No Dv8.803.305.0.Pr , Fuel Pipe From Coach Tank To To Fuel Pre Filter Cart Part No Dv8.803.41.0.Pr , Fuel Pipe From Pre Filter To Fuel Flow Meter (Suction) Cart Part No Dv8.803.42.0.Pr , Fuel Pipe From Flow Meter To Coach Tank Return Cart Part No Dv8.803.43.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 1 Lhs From F W E Cart Part No Dv8.803.62.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 1 Rhs From F W E Cart Part No Dv8.803.67.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 2 Rhs From F W E Cart Part No Dv8.803.68.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 2 Lhs From F W E Cart Part No Dv8.803.69.0.Pr , Metallic Pipe Fuel Flow Meter Out To Main Filter (Suction) Cart Part No Dv8.803.85.0.Pr , Fuel Pipe Return To Fuel Flow Meter Return Cart Part No Dv8.803.87.0.Pr , Exhaust Pipebellow To Catcon Cart Part No Dv8.806.103.0.Pr , Adaptor (M14 X 1.5 Both Side) Cart Part No Dv8.806.97.0.Pr , Adaptorm16 X 1 5 And M20 X 1 5 Cart Part No Dv8.806.98.0.Pr , Wet Pm Kit(W/O Oil) For Dv8.8301,Dv8.9207 Cart Part No Dv8.830.1.0.Sp , Control Panel Assembly For Fire Fighting Application Cart Part No Dv8.851.10.0.Pr , Engine Wiring Harness Assembly For Dv8 Fire Fighting Application Cart Part No Dv8.852.10.0.00 , 1500 Hrs C Check Maintenance Kit Dv8 8501 C4dv8 8542 C4 Cart Part No Dv8.854.01.0.Sp , Engine Control Panel To Alternator Control Harness Cart Part No Dv8.854.20.0.Pr , Control Panel Assembly For Dv8ta Cpcb4+ Cart Part No Dv8.854.30.0.Pr , 320Kva Avr (Dslr) Cart Part No Dv8.856.19.0.00 , Control Panel Stand Cart Part No Dv8.856.31.0.Pr , Adv Load Dump Module 24Vdc Cart Part No Dv8.858.16.0.00 , Engine Control Panel Assembly Sf Kg 745 Unit & 4-20 Ma Lop Cart Part No Dv8.866.10.0.00 , Engine Control Panel Assembly Sf Kg 745 Unit & 4-20 Ma Lop Cart Part No Dv8.867.10.0.00 , Engine Controlpanel Assembly Cart Part No Dv8.867.50.0.00 , Control Panel Assembly For Dv Series Cpcb4 Cart Part No Dv8.868.70.0.Pr , Interface Box Assembly Cart Part No Dv8.868.80.0.Pr , Interface Box Assembly Cart Part No Dv8.869.10.0.Pr , Cold Start Kit Main Assembly For L2 Level Application(24V System) Dv8 500Kva Cart Part No Dv8.870.50.0.Sp , Silencer For Dv8 320 Kvaproject Lakshya Cart Part No Dv8.875.21.0.Pr , Avr R450-Kg 47.2,Kva Rating-380 To 1010 Kva ,3Ph Cart Part No Dv8.901.01.0.Asp , Coupling Disc14kg 47 2 Kva Rating 380 To 600Kva3ph Cart Part No Dv8.901.13.0.Asp , Assembly For 3 Pin Male Connector Cart Part No Dv8.903.09.0.00 , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 2 3 4 For Cpcb4 Cart Part No Dv8.906.03.0.Pr , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 1 For Cpcb4 Cart Part No Dv8.906.04.0.Pr , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 8 For Cpcb4 Cart Part No Dv8.906.06.0.Pr , Air Heater Wiring Harness Cart Part No Dv8.906.36.0.Pr , Interface Box Assembly For Rdso Cart Part No Dv8.906.61.0.Pr , Rdso Ewh Ecu Chamber 5 6 7 Cart Part No Dv8.906.74.0.Pr , Dcu Wiring Harness For Dv8 Rdso Cart Part No Dv8.906.76.0.Pr , A057e698mdl Ovm 3Ph Cart Part No Dv8.906.92.0.00 , Avr Cart Part No Dv8.906.93.0.00 , Engine Wiring Harness Assemblyfor Dv8 Engine With Kg545 Unit With Conector Cart Part No Dv8.910.20.0.00 , Engine Wiring Harness Assemblyfor Dv8 Engine With Kg545 Unit 4 20 Ma Gems Lop Cart Part No Dv8.910.50.0.00 , Engine Wiring Harness Assembly Cart Part No Dv8.910.60.0.00 , Engine Wiring Harness Assembly Cart Part No Dv8.910.70.0.00 , Cold Starting Wiring Harness For Dv8 Genset Cart Part No Dv8.910.90.0.Pr , Engine Harness Master Ecu To Sensors For Dv8 250Kva Png Genset Cart Part No Dv8.913.50.0.Pr , Engine Harness Slave Ecu To Sensors For Dv8 250Kva Png Genset Cart Part No Dv8.913.60.0.Pr , Engine Harness Master Ecu To Sensors For Dv8 250Kva Png Genset (Cpcb4+) Cart Part No Dv8.913.70.0.Pr , Engine Harness Slave Ecu To Sensors For Dv8 250Kva Png Genset (Cpcb4+) Cart Part No Dv8.913.80.0.Pr , Wet Pm Kit (W/O Oil) For Dv8.9214, Dv8.9306 - Dv8 Cart Part No Dv8.921.04.0.Sp , Coupling Element Cart Part No Dv8.991.35.1.Sp , Coupling Cart Part No Dv8.991.36.0.Pr , Wet Pm Kit (W/O Oil) For Dv8.1045... - Dv8 Cart Part No Dv8.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1501, Dv8.9207, Dv8.8301 - Dv8 Sr2 Cart Part No Dv8.999.14.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1223 - Dv8.Sr1 Cart Part No Dv8.999.15.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1201 - Dv8 Sr1 Cart Part No Dv8.999.16.0.Sp , Solenoid Valve For 125/250Kva Cart Part No Dv8.999.71.0.Sp , Pressure Regulator First Level For 250 Kvar 5201 Vi Cart Part No Dv8.999.73.0.Sp , Pressure Gauge0 1600 Mmwcstub Size 3 8Bsp Cart Part No Dv8.999.74.0.Sp , Filter Assembly 1? Bsp(F) (F0112 Iii) Cart Part No Dv8.999.76.0.Sp , Filter Service Kit (Consisting Of O Ring & Filter Mesh) (F0112 Iii K) Cart Part No Dv8.999.77.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.8101 - Dv8ta G1 Cart Part No Dv8.999.86.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.9306...,Dv8.8308...,Dv8.8206...,Dv8.9214..., Dv0.9018... - Dv10 Cart Part No Dv8.999.93.0.Sp , Wet Pm Kit (W/O Oil ) For Dv8.8501.C4 Cart Part No Dv8.999.94.0.Sp , Exhaust Temp Sensor T6 Before Mixer For Cpcb4 Cart Part No Dv8.Egt4.28.0.Pr , Main Bearing Pair Grooved Ra3 Cart Part No F.038.4.01.003 , Main Bearing Pair Grooved Ra3 Cart Part No F.038.4.01.013 , Main Bearing 020 O/S Pair Cart Part No F.038.4.01.023 , Main Bearing: Ha394 Cart Part No F.073.4.00.003 , Main Bearing: Ha394 Cart Part No F.073.4.00.013 , Main Bearing: Ha394 Cart Part No F.073.4.00.023 , Main Bearing 030 O/S Cart Part No F.073.4.00.033 , Main Bearing Pair Cart Part No F.547.4.00.003 , Dowel (Din 1472-6X18-St)Or Grooved Pins Cart Part No F6.001.07.0.00 , Oil Spray Assembly Cart Part No F6.001.103.0.00 , Oil Spray Assembly Cart Part No F6.001.104.0.00 , Pressure Reducing Nozzle Cart Part No F6.001.24.0.00 , Intermediate Gear(For Oil Pump) Cart Part No F6.001.26.0.00 , Intermediate Shaft Cart Part No F6.001.27.0.00 , Plate Cover For Rear Side Cart Part No F6.001.28.0.00 , Ball Bearing Cart Part No F6.001.29.0.00 , Spacer(20X28x1-Din 988) Cart Part No F6.001.30.0.00 , Relief Valve Assly Cart Part No F6.001.31.0.00 , Taper Spacer. Cart Part No F6.001.38.0.00 , Hub Cart Part No F6.001.44.0.00 , Back Plate Cart Part No F6.001.45.0.00 , Sealing Cap (26 Din 443) Cart Part No F6.001.54.0.00 , Dowel (10X32 Din1474)Grooved Pins Cart Part No F6.001.57.0.00 , Sealing Cap Cart Part No F6.001.58.0.00 , Intermediate Mediate Gear With Bush Cart Part No F6.001.66.0.00 , Banjo Bolt: M12x1.5 Cart Part No F6.001.87.0.00 , Sealing Cap Cart Part No F6.001.91.0.00 , Joint: Front Plate Cart Part No F6.002.02.0.00 , Front Plate Cart Part No F6.002.06.0.00 , Dowel Cart Part No F6.003.04.0.00 , Deflector Cart Part No F6.003.05.0.00 , Socket Head Screw(Din 912 M16x50-10.9) Cart Part No F6.003.06.0.00 , Deflector For Fwe Oil Seal Cart Part No F6.003.09.0.00 , Crankshaft Gear Cart Part No F6.003.11.0.00 , Camshaft Gear Cart Part No F6.004.03.0.00 , Spinon Filter Assly Cart Part No F6.004.09.0.00 , Tappet Cart Part No F6.004.14.0.00 , Push Rod Assly Cart Part No F6.004.40.0.00 , Fuel Filter & Water Seperator Cart Part No F6.004.58.0.00 , Connecting Rod Bolt Cart Part No F6.005.02.0.00 , Piston Pin Cart Part No F6.005.12.0.00 , Connecting Rod Assly Cart Part No F6.005.30.0.00 , Piston Ring Set (Std.) Cart Part No F6.005.71.0.00 , Rubber Ring Cart Part No F6.006.02.0.00 , Sealing Ring: Bottom Cart Part No F6.006.03.0.00 , Valve Guide Cart Part No F6.007.02.0.00 , Valve Seat Insert Inlet Cart Part No F6.007.03.0.00 , Valve Seat Insert Exhaust Cart Part No F6.007.04.0.00 , Valve Collet Pair Cart Part No F6.007.07.0.00 , Valve Spring Cup Cart Part No F6.007.08.0.00 , Valve Spring -Outer Cart Part No F6.007.09.0.00 , Socket Head Bolt For Cylinder Head (M12x1.75X140 - Grade 12.9) Cart Part No F6.007.101.0.00 , Valve Spring (Inner) Cart Part No F6.007.11.0.00 , Washer Cart Part No F6.007.12.0.00 , Washer Cart Part No F6.007.13.0.00 , Valve Seal Cart Part No F6.007.14.0.00 , Rocker Support Sub Assembly Cart Part No F6.007.15.0.00 , Ball Screw Cart Part No F6.007.19.0.00 , Lever Clamp Cart Part No F6.007.21.0.00 , Cylinder Head Bolt: Long Cart Part No F6.007.22.0.00 , Cylinder Head Bolt: Short Cart Part No F6.007.23.0.00 , Cyl Head Gasket 1.25 Mm Thk Cart Part No F6.007.26.0.00 , Banjo Bolt :M8x1 Cart Part No F6.007.31.0.00 , Straight Thr Socket Cart Part No F6.007.33.0.00 , Sealing Cap Cart Part No F6.007.34.0.00 , Sealing Cap Cart Part No F6.007.35.0.00 , Oil Supply Pipe Assly Cart Part No F6.007.40.0.00 , Valve Pair Inlet & Exhaust Cart Part No F6.007.55.0.00 , V.R. Lever & Bush Assly Cart Part No F6.007.60.0.00 , Cyl Head Gasket 1.25 Mm Thk Cart Part No F6.007.96.0.00 , Cylinder Head Gasket Cart Part No F6.007.98.0.00 , Washer Cart Part No F6.007.99.0.00 , Rocker Cover Cart Part No F6.008.01.0.00 , Joint: Rocker Cover Cart Part No F6.008.02.0.00 , Threaded Bush Cart Part No F6.009.04.0.00 , Oil Seal: 100X75x10 Teflon Ge Cart Part No F6.009.16.0.00 , O Ring: Id 65 Dia 5 - 21516 Cart Part No F6.009.27.0.00 , Joint: Suction Connection Cart Part No F6.009.39.0.00 , Dipstick Assembly Cart Part No F6.011.01.0.00 , O Ring: Dipstick 7X2 Tgl 6365 - 21511 Cart Part No F6.011.04.0.00 , Dipstick Asm Cart Part No F6.011.60.0.Pr , Lube Oil Sump: Sheet Metal Cart Part No F6.012.01.0.00 , Breather Housing Cart Part No F6.013.01.0.00 , Pipe Cart Part No F6.013.02.0.00 , Venting Pot Cart Part No F6.013.04.0.00 , Outlet Pipe Cart Part No F6.013.11.0.00 , O Ring: 30 Id Dia 2- 21509 Cart Part No F6.013.12.0.00 , Rubber Hoses: 40Lg Cart Part No F6.013.13.0.00 , Hose Cart Part No F6.013.22.0.00 , Crank Pulley.(Finish.) Cart Part No F6.015.01.0.00 , Driven Hub Cart Part No F6.015.02.0.00 , Damper Cart Part No F6.015.03.0.00 , Thrust Plate Cart Part No F6.015.04.0.00 , Hex Bolt For Crank-Pulley Cart Part No F6.015.07.0.00 , Crank Pulley Pcd 155, Pcd 210 Cart Part No F6.015.31.0.00 , Rubber Cap Cart Part No F6.016.12.0.00 , Oil Seal: 150X120x13.5 Teflon Fwe Cart Part No F6.016.16.0.00 , Shaft Cart Part No F6.017.02.0.00 , Pulley Cart Part No F6.017.03.0.00 , Bracket For Fan Pulley Mounting Cart Part No F6.017.17.0.00 , Ball Bearing(Din 625-6306-2Rs1) Cart Part No F6.017.21.0.00 , Pulley Assly: Fan Drive Cart Part No F6.017.30.0.00 , Fan Pulley Poly V Pcd 155 Cart Part No F6.017.31.0.00 , Fan Drive Pulley Assly Cart Part No F6.017.50.0.Pr , Bracket Cart Part No F6.018.01.0.00 , Pulley Cart Part No F6.018.05.0.00 , Deep Groove Ball Bearing Cart Part No F6.018.14.0.00 , Eye Bolt Cart Part No F6.018.19.0.00 , Belt Tensioning Unit Assembly Cart Part No F6.018.20.0.00 , Swivel Piece Cart Part No F6.018.21.0.00 , Adaptor Cart Part No F6.018.22.0.00 , Bracket: Pulley Assly Cart Part No F6.018.30.0.00 , Belt Tension Pulley Pcd 90 Cart Part No F6.018.31.0.00 , Belt Tensioning Unit Assly Cart Part No F6.018.40.0.00 , V-Belt (Avx 13 X 1562 L) Cart Part No F6.019.16.0.00 , V Belt: Avx13 X 1015 Length Cart Part No F6.019.17.0.00 , Pump Driving Gear Cart Part No F6.021.11.0.00 , O Ring 28X5 Tgl 6365 -21509 Cart Part No F6.021.15.0.00 , Rubber Boot Cart Part No F6.022.05.0.00 , Gasket. Cart Part No F6.022.08.0.00 , Suction Tube Cart Part No F6.022.20.0.00 , Pipe Sub Assembly Cart Part No F6.023.20.0.00 , Threaded Adaptor Cart Part No F6.024.03.0.00 , Joint: Centrifuge Cleaner Cart Part No F6.024.07.0.00 , Joint For Lub Oil Filter Header Cart Part No F6.024.103.0.00 , O Ringid 20 Dia 2 Mat 21516 Cart Part No F6.024.17.0.00 , Relief Valve Assly Cart Part No F6.024.40.0.00 , Centrifuge Filter Cart Part No F6.024.46.0.00 , O Ring: Drain Plug Cart Part No F6.024.47.0.00 , Assembly Of Lube Oil Filter & Header Cart Part No F6.024.50.0.00 , Lube Oil Filter Header Cart Part No F6.024.74.0.00 , Joint: Glacier Filter Cart Part No F6.024.75.0.00 , Joint: Oil Return Turbo Cart Part No F6.024.77.0.00 , Gasket For Crankcase Breather) Cart Part No F6.024.78.0.00 , Joint Cart Part No F6.024.81.0.00 , Joint: Special Adaptor Piece Cart Part No F6.024.82.0.00 , Joint Cart Part No F6.024.83.0.00 , Joint: Water Pump Cart Part No F6.024.85.0.00 , Joint: Delivery Pipe Cart Part No F6.024.86.0.00 , Joint: Cooler Box Cart Part No F6.024.88.0.00 , Joint: Header Cart Part No F6.024.91.0.00 , Joint: Oil Sump Cart Part No F6.024.93.0.00 , Joint: Flange Cart Part No F6.024.94.0.00 , Joint: Flywheel Housing Cart Part No F6.024.95.0.00 , Joint: Front Plate Cart Part No F6.024.96.0.00 , Joint: Gear Casing Cart Part No F6.024.97.0.00 , Joint: Inlet Manifold Cart Part No F6.024.98.0.00 , Charge Air Manifold Cart Part No F6.025.07.0.00 , Joint: Exhaust Manifold Cart Part No F6.026.03.0.00 , Spacer Sleeve Cart Part No F6.026.04.0.00 , Gasket For Exhaust Manifold Cart Part No F6.026.06.0.00 , Starter Sm 130Pe Cart Part No F6.028.01.0.00 , Flange Cart Part No F6.029.01.0.00 , Adaptor Cart Part No F6.029.02.0.00 , Fuel Pump Cart Part No F6.029.10.0.00 , Fuel Pump Gear Cart Part No F6.029.101.0.Pr , Adaptor Cart Part No F6.029.102.0.Pr , Housing Cart Part No F6.029.103.0.Pr , Shaft Distributor Drive Cart Part No F6.029.104.0.Pr , Cam Tone Wheel Adaptor Cart Part No F6.029.105.0.Pr , Joint (Between Housing & Flange) Cart Part No F6.029.106.0.Pr , Cover Plate For Housing Cart Part No F6.029.107.0.Pr , Clamping Nutfor Pump Cart Part No F6.029.18.0.00 , Lube Oil Supply Pipe(Crank Case To Fuel Pump) Cart Part No F6.029.19.0.00 , Intermediate Flange Assembly Cart Part No F6.029.20.0.00 , Fuel Pump Gear Cart Part No F6.029.92.0.00 , Pipe Assembly Cart Part No F6.030.10.0.00 , High Press Pipe Assly Cart Part No F6.030.40.0.00 , Cup Seal Cart Part No F6.031.02.0.00 , Fork For Injector Cart Part No F6.031.03.0.00 , Speherical Washer Cart Part No F6.031.05.0.00 , Injector Cart Part No F6.031.07.0.00 , Sealing Washer[2 916 710 602] Cart Part No F6.031.51.0.00 , Banjo Bolt: Hollow Bolt Cart Part No F6.032.05.0.00 , Vent Pipe Sub Assly Cart Part No F6.032.20.0.00 , Sub Assly Of Vent Tube Cart Part No F6.032.40.0.00 , Vent Tube Assembly Cart Part No F6.032.70.0.00 , Bracket For Fuel Filter Cart Part No F6.034.06.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No F6.034.08.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No F6.034.11.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No F6.034.12.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No F6.034.14.0.00 , Lube Oil Cooler -Plate Type Cart Part No F6.036.01.0.00 , Water Drain Plug Cart Part No F6.036.06.0.00 , Joint: Lube Oil Cooler Cart Part No F6.036.11.0.00 , Sealing Washer Cart Part No F6.040.01.0.00 , Rocker Cover Cart Part No F6.040.03.0.00 , Oil Filler Cap Cart Part No F6.040.04.0.00 , Oil Filler Capplastic Cart Part No F6.040.05.0.00 , Injector Cart Part No F6.042.31.0.00 , Leak Off Pipe Assembly Cart Part No F6.043.10.0.00 , Leak Off Pipe With Flex Element Cart Part No F6.043.20.0.00 , Flywheel Housing Cart Part No F6.044.01.0.00 , Joint For Front Plate4v Common Rail Cart Part No F6.046.04.0.Pr , Pigtail For Lop Sensor Cart Part No F6.046.115.0.Pr , Pigtail For Vdo Sensor Cart Part No F6.046.116.0.Pr , Adaptor For Water Temp Sensor Cart Part No F6.063.71.0.00 , Charging Alternator Cart Part No F6.063.74.0.00 , Hose For Drain Pump Out Cart Part No F6.064.52.0.00 , V Belt: 4Pk1280 Poly Cart Part No F6.064.95.0.00 , Hose: Air Cleaner Cart Part No F6.065.27.0.00 , Drain Pipe Cart Part No F6.065.38.0.00 , Flywheel Housing Cart Part No F6.073.25.0.00 , Gas Train Assly Cart Part No F6.086.25.0.Pr , Exhaust Manifold Lagging Sl90 Cart Part No F6.086.39.0.Pr , Woodward Trim Down Pg Plus System For 6 Cylinder Natural Gas Genset Cart Part No F6.086.50.0.Pr , 3 Way Single Brick Catcon For Sl90 Png 40 Gm Ft3 Loading With Insulation 5 0 1 Cart Part No F6.086.58.0.Pr , Hoserocker Cover To Ccv Cart Part No F6.086.88.0.Pr , Pipe(Cac To Inlet Manifold) Cart Part No F6.1002.08.0.00 , Joint For Inlet Manifold Cart Part No F6.1002.15.0.00 , Inlet Manifold Cart Part No F6.1002.27.0.Pr , Copper Washerfor Spark Plug Thickness 0 5 Mm Cart Part No F6.1002.32.0.Pr , Copper Washerfor Spark Plug Thickness 0 8 Mm Cart Part No F6.1002.33.0.Pr , Copper Washerfor Spark Plug Thickness 1 Mm Cart Part No F6.1002.34.0.Pr , Governor Card Cart Part No F6.1005.01.0.00 , Converter Cable Cart Part No F6.1005.04.0.00 , Wiring Harness Assly: 250Kva Cart Part No F6.1020.10.0.00 , Engine Wiring Harness With Kg 54 Unit Cart Part No F6.1020.40.0.00 , Engine Wiring Harness Sf Kg545 Unit With Elect. Gov And 4-20Ma Lop Transmitter Cart Part No F6.1020.50.0.00 , Engine Wiring Harness Assembly With Kg545 Unit Cart Part No F6.1020.70.0.00 , Engine Wiring Harness Assembly With Kg545 Unit Cart Part No F6.1020.80.0.00 , Alternator To Control Panel Wiring Harness Cart Part No F6.1024.10.0.00 , Koel Green Alternator,320Kva,Frame Kg 45 C,Sae1/14,415V,50Hz,0.8Pf,High Efficienc Cart Part No F6.1025.05.0.Pr , Engine Control Panel Sf Png Sl90 Engine With Woodward Ecu Kg645 Controller Cart Part No F6.1034.60.0.Pr , Engine Wiring Harness Assemblywith 16 Pin Conn.(Dse 6120 Mkii Unit) Cart Part No F6.1035.10.0.00 , Engine Wiring Harness For 125Kva Biogas Genset Cart Part No F6.1040.50.0.Pr , Engine Wiring Harness Sf Sl90 Png (125Kva) Cart Part No F6.1040.80.0.Pr , Control Panel Assembly S/F 200/250Kva Cart Part No F6.1041.50.0.00 , Engine Wiring Harness For Sl90 Crdi Cpcb4+ Cart Part No F6.1043.10.0.Pr , Engine Wiring Harness For Sl90 320Kva Cpcb 4+ Cart Part No F6.1043.20.0.Pr , Engine Wiring Harness For Sl90 320Kva Cpcb Iv Engine Cart Part No F6.1043.80.0.Pr , Engine Wiring Harness For Sl90 Crdi Cpcb Iv For Genset A Cart Part No F6.1051.10.0.Pr , Engine Wiring Harness For Sl90 Crdi Cpcb Iv For Genset B Cart Part No F6.1051.20.0.Pr , Canopy Wiring Harness For Sl90 640Kva(2X320kva) Cpcb Iv Cart Part No F6.1051.30.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset A Cart Part No F6.1051.40.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset B Cart Part No F6.1051.50.0.Pr , Fip: 200Kva C Type Lever Cart Part No F6.1101.01.0.00 , Cooling Line 1 1 4 24Vassly For Kfp6s Uf35 Sl90taengines S F Flow Switch For Fi Cart Part No F6.1106.40.0.Pr , Cooling Line Assembly (1 1/4, 24V) Cart Part No F6.1106.60.0.00 , Cylinder Head Sub Assly Cart Part No F6.111.20.0.00 , H Ppipe Assly Cyl No 1 Sl90 4Vcommon Rail Cart Part No F6.1127.10.0.Pr , H Ppipe Assly Cyl No 2 Sl90 4Vcommon Rail Cart Part No F6.1127.20.0.Pr , H Ppipe Assly Cyl No 3 Sl90 4Vcommon Rail Cart Part No F6.1127.30.0.Pr , H Ppipe Assly Cyl No 4 Sl90 4Vcommon Rail Cart Part No F6.1127.40.0.Pr , H Ppipe Assly Cyl No 5 Sl90 4Vcommon Rail Cart Part No F6.1127.50.0.Pr , H Ppipe Assly Cyl No 6 Sl90 4Vcommon Rail Cart Part No F6.1127.60.0.Pr , H P Pipe Assembly 1Pump To Railsl90 4V Cart Part No F6.1127.70.0.Pr , H P Pipe Assembly 2Pump To Railsl90 4V Cart Part No F6.1127.80.0.Pr , Suction Connection For Fire Fighting Cart Part No F6.121.02.0.00 , Silencer Cart Part No F6.123.02.0.00 , Silencer Cart Part No F6.123.03.0.00 , Flange Cart Part No F6.123.06.0.00 , Anti Vibration Mounts Cart Part No F6.126.02.0.00 , Breather Pipe(Moduled Rubber Hose With Reinforcement Plies ) For 160 & 250 Kva Cart Part No F6.138.01.0.00 , Breather Hose Cart Part No F6.138.02.0.00 , Hose For Gas Inlet To Mixer Cart Part No F6.138.05.0.Pr , Breather Hose (From Engine Breather To Pipe) Cart Part No F6.138.06.0.Pr , Pipe For Air Cleaner Cart Part No F6.138.13.0.Pr , Joint: Exhaust Silencer Cart Part No F6.149.02.0.00 , Flange Cart Part No F6.149.03.0.00 , Radiator Cart Part No F6.150.01.0.Sp , Stay For Radiator Cart Part No F6.150.02.0.00 , Hose Cart Part No F6.150.03.0.00 , Pipe: Thermostat To Radiator Cart Part No F6.150.04.0.00 , Fan Spacer Cart Part No F6.150.06.0.00 , Hose: Water Out Cart Part No F6.150.13.0.00 , Hose: Radiator To Water Pump Cart Part No F6.150.17.0.00 , Aluminium Radiator Assembly For 200 Kva Cart Part No F6.150.91.0.Pr , Union Adoptor Cart Part No F6.151.02.0.00 , Gear With Bearings Cart Part No F6.151.26.0.00 , Piston Assembly Cart Part No F6.153.20.0.00 , Cyl Liner Assembly Cart Part No F6.154.10.0.00 , Cylinder Head Sub Assembly Cart Part No F6.155.20.0.00 , Cylinder Head Subassembly Cart Part No F6.155.30.0.Pr , Thermostat Cover: Finish Cart Part No F6.156.03.0.00 , Joint For Blanking Plate(Non Asbestos) Cart Part No F6.156.42.0.00 , Cover Plate Cart Part No F6.156.43.0.00 , Joint: Thermostat Cover & Gear Casing Cart Part No F6.156.44.0.00 , Gear Casing: Cast Iron Cart Part No F6.156.45.0.00 , Shim For Speed Phase Sensor Cart Part No F6.156.59.0.Pr , Shim For Speed Phase Sensor Cart Part No F6.156.61.0.Pr , Shimfor Speed Phase Sensors Cart Part No F6.156.62.0.Pr , Cylinder Head Assly Cart Part No F6.157.10.0.00 , Rocker Support Assembly Cart Part No F6.157.50.0.00 , Water Pump Sub Assly Cart Part No F6.164.20.0.00 , Charged Air Manifold (Finish.) Cart Part No F6.167.02.0.00 , O Ring.(68X3 Tgl 6365)Co.Std.21509 Cart Part No F6.167.03.0.00 , Bend Engine Side Cart Part No F6.167.06.0.00 , O Ring: 90X3 Tgl 6365- 21509 Cart Part No F6.167.14.0.00 , R Rings: 65X2.5 Cart Part No F6.168.02.0.00 , Cold Starting Kit For Sl90 200 Kva And 250 Kva L1 To L3 Cart Part No F6.1684.90.0.00 , Oil Return Adaptor Cart Part No F6.169.02.0.00 , Pipe Cart Part No F6.169.03.0.00 , Flange Engine Side Cart Part No F6.169.04.0.00 , Hose: Turbocharger Air Outlet Cart Part No F6.169.09.0.00 , O Ring: 22 Id Dia5 - 21509 Cart Part No F6.169.15.0.00 , Oil Supply Pipe Sub Assly (For T/C) Cart Part No F6.169.20.0.00 , Joint For Oil Return Pipe Crankcase Side Cart Part No F6.169.21.0.00 , Joint For Oil Return Pipe Turbocharger (Non Asbestos) Cart Part No F6.169.31.0.00 , Joint For Oil Supply Turbocharger (Non Asbestos) Cart Part No F6.169.32.0.00 , Gasket For Oil Return Pipe Turbo Charger(Non Asbestos) Cart Part No F6.169.33.0.00 , Exhaust Mfold: Lh Piece Cart Part No F6.177.01.0.00 , Exhaust Manifold (Rh) Cart Part No F6.177.02.0.00 , Exhaust Mfold: Central Open Cart Part No F6.177.03.0.00 , T/C L.O.Drain Connector: Ccase Cart Part No F6.177.11.0.00 , Lube Oil Drain Connector Cart Part No F6.177.12.0.00 , Spacer Sleeve (Copper Coated) Cart Part No F6.177.13.0.00 , Exhaust Manifoldleft Side Cart Part No F6.177.22.0.Pr , Exhaust Manifold R H Side Cart Part No F6.177.23.0.Pr , Exhaust Manifoldcentral Opening Cart Part No F6.177.24.0.Pr , Clampfor Turbo Oil Inlet Pipe Cart Part No F6.177.29.0.00 , Rubber Sleeve Cart Part No F6.177.31.0.00 , Spacer (For Turbocharger Oil Supply Pipe) Cart Part No F6.177.32.0.00 , Oil Supply Pipe Sub Assembly ( With Flex. Member ) Cart Part No F6.177.40.0.00 , Oil Supply Pipe Sub Assly (With Flex Member ) Cart Part No F6.177.50.0.00 , Lube Oil Pump: High Discharg Cart Part No F6.178.10.0.00 , Lube Oil Pump Cart Part No F6.178.50.0.00 , Crankcase Assly Cart Part No F6.182.100.0.00 , Crankcase Assly. (With 7 Bolt) (F6.182.110.0.Pr) Cart Part No F6.182.110.0.Sp , Crankcase Assembly (With Main Bearing Cap & Sealing Cap) (F6.182.130.0.Pr) Cart Part No F6.182.130.0.Sp , Piston Cooling Nozzle Cart Part No F6.182.34.0.Pr , Crankcase Assembly Cart Part No F6.182.90.0.Sp , V Belt: 4Pk-1570 Poly Cart Part No F6.184.01.0.00 , V Belt: 8Pk 983 Poly Cart Part No F6.184.02.0.00 , Poly V Belt 8Pk:1065 Cart Part No F6.184.03.0.00 , Poly V Belt 4Pk: 1515 Cart Part No F6.184.04.0.00 , Poly V Belt - 9Pk-1214 Cart Part No F6.184.07.0.Pr , Poly V Belt - 4Pk-1280 Cart Part No F6.184.08.0.Pr , Exhaust Pipe With Bellow (Turbo Outlet To Egt Inlet) Cart Part No F6.187.103.0.Pr , 36Wing Fan For Sl90 Cpcb4application Cart Part No F6.187.104.0.Pr , Gasketfor Dosing Module Cart Part No F6.187.112.0.Pr , Joint (12 Egt Inlet) Cart Part No F6.187.12.0.Pr , Joint (12 Egt Outlet) Cart Part No F6.187.13.0.Pr , Fan: 34 Plastic Cart Part No F6.187.15.0.00 , Adblue Tank Clamp (45 Lit) Cart Part No F6.187.18.0.Pr , 45L Ad Blue Tank Assembly Cpcb4 Cart Part No F6.187.19.0.Pr , Radiator Fan (36) Cart Part No F6.187.22.0.00 , 12Egt Clamp Cart Part No F6.187.27.0.Pr , Rubber Sleeve For Tank Clamp Cart Part No F6.187.29.0.Pr , Radiator Cart Part No F6.187.70.0.00 , Fan Spacer Cart Part No F6.187.71.0.Pr , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No F6.187.72.0.Pr , Radiator Outlet Hose Cart Part No F6.187.74.0.Pr , Aluminium Radiator Assembly Cart Part No F6.187.75.0.Pr , Radiator Fan 36 Cart Part No F6.187.79.0.Pr , Exhaust Pipe With Bellow Turbo To Egt Inlet Cart Part No F6.187.85.0.Pr , Anti Vibration Mount For Radiator Cart Part No F6.187.92.0.Pr , Radiator Outlet Hose Cart Part No F6.187.96.0.Pr , Shaft For Fan Pulley Cart Part No F6.192.04.0.00 , Bracket For Fan Pulley Mounting 250 Kva Cart Part No F6.192.05.0.00 , Ball Bearing Cart Part No F6.192.07.0.00 , V Belt: Cogged Bx40-1060 Cart Part No F6.192.11.0.00 , Bracket Subassemblys F Fan Mounting Cart Part No F6.192.20.0.00 , Fan Pulley Pcd 160 Cart Part No F6.192.21.0.00 , Fan Pulley Assembly Cart Part No F6.192.30.0.00 , Fan Pulley Assembly Cart Part No F6.192.51.0.00 , Belt Tensioning Unit Assly Cart Part No F6.193.20.0.00 , Belt Tension Unit Assembly Cart Part No F6.193.30.0.00 , Joint: Exh Silencer Cart Part No F6.201.02.0.00 , Joint For Thermostat Cover Cart Part No F6.241.02.0.Pr , Jointbetwater Pump Crankcase Cart Part No F6.241.03.0.Pr , Water Pump Assembly Cart Part No F6.241.10.0.Pr , Bearing Housing (For Fan Drive) (4V Common Rail) Cart Part No F6.243.02.0.00 , Shaft Cart Part No F6.243.03.0.Pr , Fan Pulleyfinish Cart Part No F6.243.04.0.Pr , Fan Drive Assembly4v Common Rail Cart Part No F6.243.10.0.Pr , Joint Between Adaptor Front Plate4v Common Rail Cart Part No F6.244.04.0.Pr , External Spline Hub For Fuel Pump Cart Part No F6.244.09.0.00 , External Spline Hub For Fuel Pump Cart Part No F6.244.09.0.Pr , Bracket For Belt Tensioning Cart Part No F6.245.01.0.Pr , Cyl Head Sub Asslywith Valve Guide Valve Seat Insert Cart Part No F6.247.20.0.Pr , Cylinder Head Assembly Complete - (Sl90 4 Valves 300 Kva Crdi) Cart Part No F6.247.30.0.Pr , Inlet Connector Cart Part No F6.248.02.0.Pr , Crdi Injector For Sl90750htf142 Sca Cart Part No F6.248.08.0.Pr , Injector For 6Sl90ta 250 Kva Cpcb4 7 X 142 X 625K 1 3He 10 5 Cart Part No F6.248.13.0.Pr , Joint For Rocker Cover Cart Part No F6.249.03.0.Pr , Fuel Pipefor Fip To Filter Cart Part No F6.252.03.0.Pr , Fuel Pipefor Filter To Fip Cart Part No F6.252.04.0.Pr , Leak Off Pipe For Injectorpart 1 Cart Part No F6.252.11.0.Pr , Leak Off Pipe For Injectorpart 2 Cart Part No F6.252.12.0.Pr , Leak Off Pipefor Rail Pump Cart Part No F6.252.13.0.Pr , Leak Off Pipefor Fip Cart Part No F6.252.14.0.Pr , Radiator Fan: 28 Metalic Cart Part No F6.255.01.0.00 , Hose Connection Cart Part No F6.255.03.0.00 , Pipe: Thermostat To Water Tank Cart Part No F6.255.05.0.00 , Hose For Thermostat To Water Tank Cart Part No F6.255.06.0.00 , Hose: Water Connection Cart Part No F6.255.09.0.00 , Air Inlet Manifold Bend Cart Part No F6.255.12.0.00 , Joint: Bend Cart Part No F6.255.13.0.00 , Hose: Vent Connection Cart Part No F6.255.18.0.00 , Hose For Thermostat To Water Tank Cart Part No F6.255.32.0.00 , Hose: 160Kva Cart Part No F6.255.46.0.00 , Thermostat Cover Cart Part No F6.256.03.0.00 , Adaptor ( For 28 Fan ) Cart Part No F6.257.01.0.00 , Fip: 9 Mm Lift Cart Part No F6.259.10.0.00 , Extension Pipe For Catalyst Outlet Cart Part No F6.262.18.0.Pr , Fan Drive Pulley Assly S F C I Gear Casing Cart Part No F6.273.20.0.00 , Rubber Block Set(For Htb1200 Coupling) Cart Part No F6.290.20.0.00 , Cam Shaft & Gear Assembly Cart Part No F6.293.20.0.00 , Gasket (Between Turbochager & Exhaust Manifold) Cart Part No F6.294.12.0.00 , Fuel Injection Pump For 160Kva Cart Part No F6.296.10.0.00 , Radiator Cart Part No F6.297.01.0.00 , Assly Leak Off Pipe Cart Part No F6.304.01.0.00 , Gas Outlet Bend Cart Part No F6.315.01.0.00 , Expansion Bellow Cart Part No F6.315.03.0.00 , Air Delivery Bend Cart Part No F6.316.01.0.00 , Breather Pipe Support Clamp Cart Part No F6.320.09.0.00 , Leak Off Pipe: 250Kva Cart Part No F6.322.01.0.00 , Wet Pm Kit (W/O Oil) For F6.3422,F6.3423,F6.3445,F6.3622,F6.3623,F6.3624,F6.3645,F6.9623 - 6 Cart Part No F6.342.2.0.Sp , Turbocharger Cart Part No F6.350.01.0.00 , Crankshaft Assebly With Gear Cart Part No F6.351.40.0.Pr , Crankshaft Assebly With Gear Cart Part No F6.351.60.0.Pr , Flexible Connection: Ccase-Pump Cart Part No F6.353.05.0.00 , Clamping Nut For Motorpal Pump Cart Part No F6.353.09.0.00 , Fuel Pipe: Filter To Fip Cart Part No F6.353.11.0.00 , Fuel Pipe Primary To Secondary Cart Part No F6.353.112.0.00 , Fuel Pipepump To Filter Cart Part No F6.353.14.0.00 , Exhaust Manifold Cart Part No F6.357.01.0.00 , Exhaust Manifold Cart Part No F6.357.02.0.00 , Compression Ring Cart Part No F6.357.03.0.00 , Lube Oil Cooler-Plate Type Cart Part No F6.358.01.0.00 , Lub Oil Cooler Cartridge 16 Plate Cart Part No F6.358.15.0.00 , Valve Seat Insert Inlet Cart Part No F6.359.02.0.00 , Valve Seat Insert Exhaust Cart Part No F6.359.04.0.00 , Exhaust Valve Seat Insertsemifinishgas Engine Cart Part No F6.359.08.9.Pr , Cyl Head Assly Cart Part No F6.359.10.0.00 , Inlet Exhaust Valve Pair Cart Part No F6.359.12.0.Sp , Valve Pair Inlet & Exhaust Cart Part No F6.359.50.0.00 , Injector Cart Part No F6.361.02.0.00 , Copper Washernozzle Cart Part No F6.361.03.0.00 , Cooler Mounting Body Cart Part No F6.362.01.0.00 , Cooler Mounting Body (For 16 Plate Cooler) (Finish) Cart Part No F6.362.06.0.Pr , Oil Transfer Adaptor (Finish) Cart Part No F6.363.06.0.Pr , Sleeve (B/W Adaptor & Header ) Cart Part No F6.363.07.0.Pr , Oring Id 29 Od 3 Cart Part No F6.363.08.0.Pr , Lub Oil Pipe Assembly Cart Part No F6.363.10.0.Pr , Ss Joint: Turbocharger Outlet Cart Part No F6.364.02.0.00 , Stud: M10x1.5X65 Copper Coated Cart Part No F6.366.02.0.00 , Cyl Head Assly Cart Part No F6.366.10.0.00 , Nozzle For Sl90ta Cart Part No F6.368.14.0.00 , Pipe From Pump To Solenoid Cart Part No F6.371.02.0.00 , Pipe From Solenoid To Flame Heater Cart Part No F6.371.03.0.00 , V Belt: 106 Spb 1340 Cart Part No F6.375.11.0.00 , Hose Connection Cart Part No F6.375.15.0.00 , Fan: Plastic 30 Cart Part No F6.375.25.0.00 , Belt Tensioning Assly: 250Kva Cart Part No F6.375.30.0.00 , Pulley Pcd 90 Cart Part No F6.375.31.0.00 , Sub Asslycooler Cart Part No F6.376.10.0.00 , Turbocharger Cart Part No F6.377.035.0.00 , V Bend Clamp Cart Part No F6.377.04.0.00 , O Ring: Turbo Outlet Cart Part No F6.377.06.0.00 , Hose Cart Part No F6.377.08.0.00 , Joint: Turbo Inlet Cart Part No F6.377.09.0.00 , Support Bracket Assembly (For Air Pipe) (For Cpcb Ii) Cart Part No F6.377.100.0.00 , Stud: M8 Copper Coated Cart Part No F6.377.11.0.00 , Stud M10x1.5X025 (Copper Coated) Cart Part No F6.377.12.0.00 , Air Delivery Main Pipe From Tc To Cac Cart Part No F6.377.13.0.00 , Air Delivery Bend Cart Part No F6.377.14.0.00 , Joint: Air Delivery Mainpipe & Bend Cart Part No F6.377.15.0.00 , T Bolt Clamp S/F 83Mm Od Cart Part No F6.377.16.0.00 , Clamping Bracket Cart Part No F6.377.28.0.00 , Hose For Inlet Manifold Bend & Cac Out Cart Part No F6.377.33.0.00 , Cac Hose Cold Side Cart Part No F6.377.39.0.00 , Turbocharger For Sl90 Cpcb 4Engine076j89ss22n01en 080X73xl18c89esc15 Cart Part No F6.377.45.0.Pr , Crank Pulley Cart Part No F6.378.03.0.00 , Adaptor Plate Cart Part No F6.378.04.0.00 , Damper Pulley Cart Part No F6.378.11.0.00 , Damper Pulley Cart Part No F6.378.21.0.00 , Crank Pulley Pcd 210 Cart Part No F6.378.41.0.00 , Charge Air Manifold Cart Part No F6.379.01.0.00 , Inlet Manifold Bend Cart Part No F6.379.03.0.00 , Worm Drive Hose Clip (115 Mm) Cart Part No F6.379.07.0.00 , Joint: Inlet Manifold Bend Cart Part No F6.379.11.0.00 , Inlet Manifold Bend Cart Part No F6.379.14.0.00 , Joint Heater To Cac Pipe Cart Part No F6.379.17.0.Pr , Wet Pm Kit (W/O Oil) For F6.3805,F6.3806 Cart Part No F6.380.5.0.Sp , Gas Outlet Bend Cart Part No F6.381.01.0.00 , Bracket For Exhaust Outlet Cart Part No F6.381.02.0.00 , Expansion Bellow Cart Part No F6.381.03.0.00 , Joint: Bellow & Gas Outlet Cart Part No F6.381.04.0.00 , Set Screw M8x1.25X025 (Copper Coated) Cart Part No F6.381.05.0.00 , Gasket (Between Turbocharger & Diffuser) Cart Part No F6.381.15.0.Pr , Cyl Liner Assembly Cart Part No F6.382.10.0.00 , Cylinder Liner Assly. Cart Part No F6.382.20.0.Pr , Air Filter Primary Cart Part No F6.3855.51.0.Pr , Air Filter Safety Cart Part No F6.3855.52.0.Pr , Adaptor On Cooler Mtgbody For Jacket Water Heater Conn Cart Part No F6.387.03.0.00 , Valve Guide Finish Cart Part No F6.4004.02.0.00 , Valve Seat Insert: Inlet Cart Part No F6.4004.03.9.00 , Valve Seat Insert: Exhaust Cart Part No F6.4004.04.9.00 , Valve Bridge Cart Part No F6.4004.08.0.00 , Valve Pair Cart Part No F6.4004.100.0.00 , Cylinder Head Bolt Cart Part No F6.4004.12.0.00 , Sealing Cap22 Dia Cart Part No F6.4004.14.0.00 , Cylinder Head Assembly Complete Sl90 4 Valves Cart Part No F6.4004.160.0.Pr , Cylinder Head Assembly Complete Sl90 4 Valves Cart Part No F6.4004.30.0.00 , Valve Guide & Snap Ring Assembly Cart Part No F6.4004.40.0.00 , Push Rod Assly Cart Part No F6.4004.50.0.00 , Rocker Support Assembly Cart Part No F6.4005.70.0.00 , Rocker Cover Cart Part No F6.4006.07.0.00 , Rocker Cover (Machining) (Withoil Filling Arrangement) ( 4 Valve) Cart Part No F6.4006.08.0.00 , Joint: Rocker Cover Cart Part No F6.4006.13.0.00 , O Ring Cart Part No F6.4007.03.0.00 , Inlet Manifold Cart Part No F6.4008.01.0.00 , Joint: Inlet Manifold Cart Part No F6.4008.02.0.00 , Blanking Plate For Inlet Manifold Cart Part No F6.4008.03.0.00 , Spacer For Exhaust Manifold Cart Part No F6.4009.06.0.00 , Gasket For Exhaust Manifoldbetcylhead Exhmanifold Cart Part No F6.4009.12.0.00 , Banjo Bolt For Leak Off Pipe Cart Part No F6.4012.05.0.00 , Fuel Pipe Pre-Filter To Feed Pump Cart Part No F6.4012.11.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No F6.4012.12.0.00 , Lube Oil Supply Pipe To Fuel Pump Cart Part No F6.4012.14.0.00 , Leak Off Pipe Cart Part No F6.4012.22.0.00 , Bracket For Fuel Pipe Cart Part No F6.4012.26.0.00 , Leak Off Pipe Cart Part No F6.4012.35.0.00 , Fuel Pipe (Fuel Filter To Fuel Pump) Cart Part No F6.4012.36.0.00 , Fuel Pipe From Fuel Tank To Fuel Pump Cart Part No F6.4012.91.0.Pr , High Pressure Pipe Assembly Cart Part No F6.4013.100.0.00 , Cam Shaft Sub Assembly Sl90 4 Valves Cart Part No F6.4014.120.0.Pr , Cam Shaft Sub Assembly Sl90 4 Valves Cart Part No F6.4014.40.0.00 , Piston Assembly Cart Part No F6.4015.30.0.00 , Joint Betgear Casing Front Plate Cart Part No F6.4018.02.0.Pr , Gear Casing (Cast Iron ) Cart Part No F6.403.01.0.00 , Hose: Air Cleaner Cart Part No F6.404.01.0.00 , Air Filter Primary Outer Element Cart Part No F6.404.101.0.Pr , Air Filter Safety Cart Part No F6.404.102.0.Pr , Air Cleaner Kit For Sl90 Cart Part No F6.404.15.0.00 , Bracket For Air Cleaner Cart Part No F6.404.17.0.00 , Air Cleaner Assly Cart Part No F6.404.25.0.00 , Air Filter Primary Cart Part No F6.404.27.0.00 , Air Filter Safety Cart Part No F6.404.28.0.00 , Restriction Indicator Cart Part No F6.404.31.0.00 , Hose Reducer Cart Part No F6.404.32.0.00 , Hose Reducer Cart Part No F6.404.36.0.00 , Fuel Return Pipe Cart Part No F6.404.56.0.Pr , Fuel Return Pipe Cart Part No F6.404.57.0.Pr , Hose Reducer Elbow Cart Part No F6.404.59.0.Pr , Hose For Air Cleaner Cart Part No F6.404.74.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No F6.406.32.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No F6.406.33.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Cart Part No F6.406.35.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Cart Part No F6.406.36.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Cart Part No F6.406.38.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No F6.406.39.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No F6.406.41.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No F6.406.43.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No F6.406.44.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Cart Part No F6.406.46.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No F6.406.47.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No F6.406.48.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No F6.406.49.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No F6.406.51.0.Pr , Fuel Inlet Pipe From Filter To Pump Cart Part No F6.406.62.0.Pr , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No F6.406.64.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Cart Part No F6.406.67.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No F6.406.68.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No F6.406.69.0.Pr , Fuel Supply And Return Block Cart Part No F6.418.01.0.00 , Fuel Leak Off Pipe Assly(Fire Fighting) Cart Part No F6.418.02.0.00 , Fuel Supply Pipefrom Supply Block To Fuel Pump Cart Part No F6.418.03.0.00 , Adaptor For Fuel Supply And Return Block Cart Part No F6.418.04.0.00 , Fuel Leak Off Pipe Assly Fire Fighting Cart Part No F6.418.05.0.00 , Leak Off Pipe Assembly Cart Part No F6.418.08.0.00 , Cover Plate Cart Part No F6.420.22.0.00 , Barring Assly Cart Part No F6.420.25.0.00 , Set Screw M14x35 For Barring Arrg Cart Part No F6.420.29.0.Pr , Cooler Cover Cart Part No F6.420.52.0.00 , Water Pump Pulley Cart Part No F6.424.01.0.00 , Water Pump Pulley Cart Part No F6.424.21.0.00 , Current Transformer (Set Of 4Ct) 500/5A For Frame-284 Cart Part No F6.443.04.0.00 , Current Transformer(Set Of 4Ct) 1000/5A Frame -354 Cart Part No F6.443.05.0.00 , 200Kva Alternator Sae 2 /11.5 Cart Part No F6.443.16.0.Pr , Engine Control Digital Display 24Vdc Cart Part No F6.465.33.0.00 , Instrumentation Control Panrl Assembly Cart Part No F6.465.50.0.00 , Starter Solenoid(Dumore, 535-0098)24V For F.Fighting Cart Part No F6.474.02.0.00 , Water Heater(Kim Hotstart, Tps202gt12-006, 2.0Kw, 240V) Cart Part No F6.482.01.0.00 , Actuator(Xadc225d1s - 24) For Fire Fighting Appln. Cart Part No F6.483.01.0.00 , Spacer For Link(M6 X1 Lh - M6x1 Rh) Cart Part No F6.483.04.0.00 , Link(M6x1 Lh - M6x1 Rh) Cart Part No F6.483.06.0.00 , Adaptor (M6x1-M6x1) Cart Part No F6.483.12.0.00 , 70 Pin Engine Control Modulesecm70 Cart Part No F6.488.01.0.Pr , Delta Pressure Sensor Sensor In The Efr Cart Part No F6.488.02.0.Pr , Sensor Cart Part No F6.488.03.0.Pr , Electronic Flow Regulator Efr Cart Part No F6.488.04.0.Pr , F Series Throttle Body Cart Part No F6.488.05.0.Pr , Ignition Coil Cart Part No F6.488.06.0.Pr , Exhaust Silencer: 4 Id Cart Part No F6.503.01.0.00 , Joint Ss: 4 Cart Part No F6.503.02.0.00 , Flange-Id 4 Cart Part No F6.503.04.0.00 , Air Cleaner: 14+Mtg Strap Cap Cart Part No F6.504.01.0.00 , Range Restriction Indicator 1/8 24 Cart Part No F6.504.02.0.00 , Air Cleaner Element-14 Cart Part No F6.504.08.0.00 , Air Cleaner Assly: Dry 11.5 Cart Part No F6.504.32.0.00 , Filter Element For 11.5Jjf Drytype Air Cleaner Cart Part No F6.504.34.0.00 , Hood For 11.5 Filter Cart Part No F6.504.35.0.00 , Adaptor: M24x1.5M-M10x1.5F Cart Part No F6.505.12.0.00 , Engine Mtg Foot Cart Part No F6.508.01.0.00 , Hard Washer(12 Id) Cart Part No F6.508.03.0.00 , 500 Hrs - B Check Maintenance Kit Cart Part No F6.508.18.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No F6.508.19.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No F6.508.22.0.Sp , Water Suction Connection Cart Part No F6.509.03.0.00 , Anti Vibration Mounts Cart Part No F6.509.04.0.00 , Hose: Radiator Inlet 50 Id Cart Part No F6.509.05.0.00 , Hose: Radiator Outlet 60 Id Cart Part No F6.509.06.0.00 , Adaptor(M14*15 To M14*2) Cart Part No F6.509.13.0.00 , Flexible Pipe: M14xm14x600 L Cart Part No F6.509.14.0.00 , Rubber Block(0.37 Holset Coupling) Cart Part No F6.510.02.0.00 , Holset Coupling 0.37 Rb 45 Mm Pilot Bore Cart Part No F6.510.10.0.00 , Ssjoint(For Turbo Outlet) Cart Part No F6.516.02.0.00 , Bracket Gas Outlet Manifold Cart Part No F6.516.05.0.00 , Charging Alternator 28V 45A Cart Part No F6.531.01.0.00 , Pulley Cart Part No F6.534.01.0.00 , Pulley 124 Pcd A Sect Cart Part No F6.534.02.0.00 , Fan Drive Assembly (S/F C.I Gear Casing) Cart Part No F6.534.20.0.00 , Starter Ring Cart Part No F6.537.02.0.00 , Flywheel Assembly Cart Part No F6.537.10.0.00 , Flywheel Assly With Starter Ring (Heavy) Cart Part No F6.537.50.0.Pr , Crank Pulley (3 Grooves,210 Pcd) Cart Part No F6.544.01.0.00 , Heat Exchanger Cart Part No F6.549.01.0.00 , Fresh Water Inlet Conn.On Heat Exchanger Cart Part No F6.549.03.0.00 , Hose: Thermostat Hsg To Int. Pipe Cart Part No F6.549.06.0.00 , Intermediate Pipe(For He In Conn)Al Cast Cart Part No F6.549.13.3.00 , Expansion Bellow: 4 With 4Mtg Hole Cart Part No F6.550.01.0.00 , Non Return Valve 1 Bsp Cart Part No F6.554.04.0.00 , Flexible Pipe (M30 X M30 U 600 L) Cart Part No F6.554.08.0.00 , Mounting Bracket For Make Up Water Tank Cart Part No F6.557.01.0.00 , Mounting Plate For Make Up Water Tank. Cart Part No F6.557.03.0.00 , Make Up Water Tank. Cart Part No F6.557.04.0.00 , Clamping Strap For Makeup Water Tank Mtg Cart Part No F6.557.05.0.00 , Special Stud Cart Part No F6.557.06.0.00 , Cover With Press Cap Cart Part No F6.557.07.0.00 , Outlet Pipe Conn On Makeup Water Tank Cart Part No F6.557.08.0.00 , Flexible Pipe Vent For W.Tank Cart Part No F6.557.09.0.00 , Compression Ring Cart Part No F6.560.01.0.00 , Stop Solenoid: 24V Energ-Run Cart Part No F6.561.04.0.00 , Exhaust Bend (S/F Schwing) Cart Part No F6.562.02.0.00 , Adaptor For Prswitch Cart Part No F6.564.01.0.00 , Holset Coupling O.37 Rb 35 Mm Pilot Bore Cart Part No F6.565.10.9.00 , Set Of O Rings: 6Sl9088t Cart Part No F6.566.10.0.00 , Set Of Joints 6Sl9088t Engine. Cart Part No F6.566.20.0.Sp , Set Of Copper Washer Cart Part No F6.566.30.0.00 , Set Of Joints For 6Sl9088ta Engine/F6.3021/F6.3221/F6.3421/F6.3621/F6.3821(Standrad)/F Cart Part No F6.566.40.0.Sp , Set Of O Rings Cart Part No F6.566.50.0.00 , Set Of Copper Washer Cart Part No F6.566.60.0.00 , Set Of Joints Cart Part No F6.566.70.0.Sp , Set Of O Rings Cart Part No F6.566.80.0.00 , Sub Assly Of Hose Tail M 12 Banjo Cart Part No F6.569.10.0.00 , Stop Solenoid: 24V Energ-Run Cart Part No F6.570.06.0.00 , Water Pump Pulley Cart Part No F6.579.01.0.00 , Water Pump Pulley Pcd 190 Cart Part No F6.579.21.0.00 , Hose For Air Cleaner Cart Part No F6.594.06.0.00 , Bush Cart Part No F6.606.03.0.00 , Washer For Axual Alignment Cart Part No F6.606.04.0.00 , Spacer Cart Part No F6.606.05.0.00 , Pulley For Alternator Cart Part No F6.606.06.0.00 , Lever Cart Part No F6.606.07.0.00 , Bracket: Alternator Cart Part No F6.606.08.0.00 , Pulley For Alternator( 2 Groove, 81 P.C.D.) Cart Part No F6.606.09.0.00 , Alternator Pulley Cart Part No F6.606.21.0.00 , Pressure Sender For Pricol Single Wire Connection Cart Part No F6.610.02.0.00 , Speed Control Cart Part No F6.614.02.0.00 , Expansion Bellow: 4 Cart Part No F6.618.01.0.00 , Joint Ss Cart Part No F6.618.02.0.00 , Engine Mtg Foot Cart Part No F6.628.01.0.00 , Engine Mounting Foot For Transportation Cart Part No F6.628.05.0.00 , Bracket For Altrnator Cart Part No F6.639.01.0.00 , Alternator: 24V 45A Wo Blocking Diode Cart Part No F6.639.04.0.00 , Bracket For 11.5Air Cleaner Cart Part No F6.640.01.0.00 , Air Cleaner Element 11.5 Cart Part No F6.640.02.0.00 , 0.73Rb Coupling Cart Part No F6.657.20.0.00 , Radiator Assly For Ural Cart Part No F6.669.01.0.00 , Fan For Ural Cart Part No F6.669.02.0.00 , Flex.Hose For Vent Cart Part No F6.669.09.0.00 , Lube Oil Drain Pipe Assly Cart Part No F6.670.34.0.00 , Hose For Air Suction Pipe Cart Part No F6.670.98.0.Pr , Joint: Air Inlet Manifold Cart Part No F6.674.04.0.00 , Radiator Al Cac 200Kva Cart Part No F6.680.01.0.00 , Pipe For Thermostat To Water Tank Of Radiator Cart Part No F6.680.04.0.00 , Rubber Hose: Main Pipe 100X100x180l Cart Part No F6.680.06.0.00 , Suction Connection Cart Part No F6.680.08.0.00 , Lug For Stay Cart Part No F6.680.11.0.00 , Stay For Radiator Cart Part No F6.680.12.0.00 , Holding Bracket Cart Part No F6.680.13.0.00 , Clamping Bracket140 To 160Kva Cart Part No F6.680.23.0.00 , T Bolt Clamp Cart Part No F6.680.25.0.00 , Circlip: Seegev Cart Part No F6.701.03.0.00 , Big End Bearing Top (Str) 250Kva Cart Part No F6.701.05.0.00 , Big End Bearing Bottom (Str) 250Kva Cart Part No F6.701.06.0.00 , Con Rod Assly: 250 Kva W/0 Brg Cart Part No F6.701.10.0.00 , Connecting Rod Assembly Cart Part No F6.701.100.0.Pr , Connecting Rod Assembly With Big End Bearing Cart Part No F6.701.110.0.Pr , Big End Bearing Top Cart Part No F6.701.16.0.Pr , Big End Bearing Bottom Cart Part No F6.701.17.0.Pr , Piston Assembly Cart Part No F6.701.20.0.00 , Connecting Rod Assly Cart Part No F6.701.40.0.00 , Piston Assembly Cart Part No F6.701.61.0.00 , Fuel Pipe Inlet Water Seprater To Fip Cart Part No F6.708.08.0.00 , Fuel Pipe Return: M12x1.5 Male Plug X M14 X 1.5 Banjo 700Mm Cart Part No F6.708.12.0.00 , Fip: 250Kva Cart Part No F6.713.01.0.00 , Adaptor Cart Part No F6.713.02.0.00 , Bracket For Fip Mounting Cart Part No F6.713.04.0.00 , Joint: Flange Cart Part No F6.713.05.0.00 , O Ring 15 I.D X1.78 Dia Section Cart Part No F6.713.08.0.00 , Adaptor For Fuel Pipem14x1 5 X 14X1 5 Cart Part No F6.713.09.0.00 , Fip For Sl90 Main Propulsion 1800 Rpm Cart Part No F6.713.105.0.Pr , Feed Pump Cart Part No F6.713.26.0.00 , Air Cleaner 16 Cart Part No F6.729.01.0.00 , Bracket For Air Cleaner Cart Part No F6.729.02.0.00 , 16Air Cleaner Primary Elemt Cart Part No F6.729.03.0.00 , Safety Air Filter Elemnt Cart Part No F6.729.04.0.00 , 16 Air Cleaner Hood With Clamp Assembly Cart Part No F6.729.05.0.00 , Primary Air Cleaner Element Cart Part No F6.729.07.0.00 , Air Cleaner Safety Element Cart Part No F6.729.08.0.00 , Hose: Air Inlet 250 Kva Cart Part No F6.729.13.0.00 , Hose: Air Cleaner Cart Part No F6.729.19.0.00 , Pipe Complete Assly With Clamps Cart Part No F6.734.10.0.00 , Bracket For Adc 225 Gs Governor Cart Part No F6.741.01.0.00 , Link: Adc C225 Gs Cart Part No F6.741.02.0.00 , Wiring Harness Cart Part No F6.741.03.0.00 , Control Unit Cart Part No F6.741.06.0.00 , Magnetic Pup Thread 16X1.5 Cart Part No F6.741.07.0.00 , Braket For Adc225 Gac Actuator Cart Part No F6.741.08.0.00 , Spacer For The Fitment Of The Governor Linkage For The Gav G Cart Part No F6.741.09.0.00 , Relay Mod 24V Dc Cart Part No F6.741.12.0.00 , Magnetic Pickup: Dual Two Connector Cart Part No F6.741.14.0.00 , Magnetic Pick Up 16X1 5 Threadingfor 250 Kva With 110 Series Mssl Con Cart Part No F6.741.16.0.00 , Magnetic Pick Up With Ampconnectorwith Econoseal J Type For Industrial Appl Cart Part No F6.741.19.0.00 , Dual O P Mpu Cart Part No F6.741.26.0.Pr , Magnetic Pick Up16x1.5 Thread Cart Part No F6.741.28.0.Pr , Dual O P Mpu Cart Part No F6.741.29.0.Pr , Magnetic Pickup: Amp Connector Cart Part No F6.741.31.0.Pr , Control Unit Esd 2210 S F Solo Cart Part No F6.742.06.0.00 , Lever For Elec Actuator Cart Part No F6.742.08.0.00 , Cac Pipe Turbo Bend Pipe To Extended Cac Cart Part No F6.744.07.0.00 , O Ringid 69 6 5 Mm Cart Part No F6.744.12.0.Pr , Cac Pipehot Side Cart Part No F6.744.14.0.Pr , Water Cooled Cac-For Fire Fighting (296Hp/1500) Cart Part No F6.746.01.0.00 , Heat Exchanger Fire Fighting Cart Part No F6.746.02.0.00 , Cac Outlet Pipe (Watercooled Cac) Cart Part No F6.746.04.0.00 , Joint: Watercooled Cac Cart Part No F6.746.05.0.00 , Hose: Suct Conn 60 Idx 70Odx 60Mm Cart Part No F6.746.14.0.00 , Rubber Hosefor Drain Pipe Cart Part No F6.748.04.0.Pr , Jointbetturbo Adaptor Crankcase Cart Part No F6.748.05.0.Pr , Jointbetween Turbo Drain Pipe Cart Part No F6.748.13.0.00 , Jointbetween Turbo Drain Pipe Cart Part No F6.748.13.0.Pr , Hose For Cac Pipe Cart Part No F6.749.11.0.Pr , Lub Oil Headerfor Sl90 320 Kva Finish Cart Part No F6.755.06.0.Pr , Plunger For Relief Valve Cart Part No F6.755.07.0.Pr , Springfor Relief Valve Cart Part No F6.755.08.0.Pr , Oringb W Header Crankcase Cart Part No F6.755.12.0.Pr , Hx40 Holset Turbo 332 2100 40 L8294 H18e Profile 8 Cart Part No F6.759.05.0.00 , Joint For Exhaust Silencer Cart Part No F6.768.02.0.00 , U Strip Clamp For 160 125Kva Cart Part No F6.768.04.0.00 , Silencer For 6Ksl90 Cpcb Iv Cart Part No F6.768.15.0.Pr , Rain Cap Cart Part No F6.768.50.0.00 , Damper Cart Part No F6.783.01.0.00 , Special Crank Pulley Cart Part No F6.784.01.0.00 , Special Driving Hub Cart Part No F6.785.01.0.00 , Expansion Bellow Cart Part No F6.786.01.0.00 , Fip For Sl90ta Cart Part No F6.795.03.0.00 , Fuel Injection Pump Assmebly Cart Part No F6.795.13.0.00 , Fuel Feed Pump9 440 0 30 003 Cart Part No F6.795.18.0.Pr , Cam Gear Speed Ring Cart Part No F6.800.07.0.Pr , Countersunk Socket Head Screw Cart Part No F6.800.08.0.Pr , Exhaust Diffuser Cart Part No F6.801.04.0.00 , Hose Forair Cleaner Cart Part No F6.801.09.0.00 , Radiator Cart Part No F6.801.10.0.00 , Hose (From Radiator To Water Pump) Cart Part No F6.801.11.0.00 , Pipe (Thermostat To Radiator) Cart Part No F6.801.13.0.00 , Fuel Return Pipe Cart Part No F6.801.15.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No F6.801.23.0.00 , T- Bolt Clamp(159Mm - 167Mm) Cart Part No F6.801.24.0.00 , Bracket For Actuator Mounting Cart Part No F6.801.25.0.00 , Vent Pipe Cart Part No F6.801.26.0.00 , Vent Pipe Cart Part No F6.801.27.0.00 , Fuel Return Pipe Cart Part No F6.801.28.0.00 , Fuel Level Sensor 145Mm Cart Part No F6.802.19.0.00 , Hard Washer( For M20 Bolt). Cart Part No F6.811.02.0.00 , Hard Washer (Id 17,Od 35,Thk 5) Cart Part No F6.811.04.0.00 , Avr Model Tavr-3A S/F Kg Alternator Cart Part No F6.814.11.0.00 , Rotating Rectifier Assly: 6 Diode Cart Part No F6.814.15.0.00 , Rotating Reefifer Assembly With 6Nos. Diode&Heatsink S/F Kg Alternator Cart Part No F6.814.16.0.00 , Excitor Rotor Assemblytex2.1 S/F Kg Alternator Cart Part No F6.814.17.0.00 , Terminal Block S/F Kg Alternator Cart Part No F6.814.25.0.00 , Nde Shield S F Kg Alternator 320Kvaframe Size Ta284c Cart Part No F6.814.48.0.00 , Avr Cart Part No F6.815.41.0.00 , Hose For Air Delivery Bend Cart Part No F6.840.05.0.00 , Hose At Cac In (100 Id X 100 Id X 80 Length) Cart Part No F6.840.16.0.00 , Relay Board: Single Chanel Cart Part No F6.857.01.0.00 , Control Panel Asslyf F Application S F Eletronic Governor With Idle And Run Sw Cart Part No F6.858.20.0.00 , Relay 24Vdc Cart Part No F6.860.11.0.00 , Dc Volt Meter 16 T0 32 V 52 Dia Cart Part No F6.863.06.0.00 , Relay Board 2.5 Ch 70 Amp Cart Part No F6.863.17.0.00 , Relay Board Cart Part No F6.865.05.0.00 , Selctor Switch2 Way With Center Off 2Pole Cart Part No F6.873.01.0.00 , Turbocharger Cart Part No F6.889.02.0.00 , Turbocharger Cart Part No F6.889.03.0.00 , Air Delivery Bend: 200Kva Cart Part No F6.889.04.0.00 , O Ring (For Turbo Outlet) Cart Part No F6.889.05.0.00 , Air Delivery Bend (Turbocharger) Cart Part No F6.889.08.0.00 , Cac Hose Hot Side 4 Plies Lakshaya Project Cart Part No F6.889.16.0.Pr , Solid State Lamp 183 Ma: 8-30V Cart Part No F6.900.23.0.00 , Low Engine Coolant Temperature Switch Cart Part No F6.906.70.0.00 , Raw Water High Temprature Switch Cart Part No F6.906.71.0.00 , Engine Coolant Temprature Switch. Cart Part No F6.906.72.0.00 , Magnetic Pickup M16x1.5 Cart Part No F6.908.01.0.00 , Low Lub Oil Pressure Switch Setting2 Bar 1/8 Npt With Two Screw Terminals Cart Part No F6.908.11.0.00 , Water Temp Switch 98 Deg C Cart Part No F6.909.69.0.00 , Wiring Harness For Fire Fighting(250Kva) Cart Part No F6.917.20.0.00 , Piston Assly For 160 Kva Gas Engine Cart Part No F6.920.10.0.00 , Wiring Harness Assembly Sl90 Fm_Ul New Cart Part No F6.928.11.0.00 , Wiring Harness: Fire Fighting Cart Part No F6.928.20.0.00 , Wiring Harness Assembly Sl-90 Engine F.F.Set (Spp Fmul Project) With Alternator Cart Part No F6.928.30.0.00 , Wiring Harness Assembly From Engine Control Panel To Main Fire Fighting Panel Cart Part No F6.928.60.0.00 , Earthing Cable (Pvc ,Green Colour) For Radiator To Starter2.5 Sq.Mm. Cart Part No F6.933.24.0.00 , Radiator With Cacverticals F 200 Kva Cart Part No F6.941.10.0.Sp , Engine Control Unit Cart Part No F6.942.01.0.00 , Actuator 24Vdc Sl90 Cart Part No F6.942.02.0.00 , Ecu E-Governer B12 24Vdc Sl90 Cart Part No F6.942.03.0.00 , Actuator: 24Vdc Sl90 Cart Part No F6.942.12.0.00 , Oil Seal Pressing Toolfwe Cart Part No F6.950.04.0.00 , Oil Seal Pressing Mandrelge Cart Part No F6.950.05.0.00 , Piston Ring Set (Pvd 4 Valve) Cart Part No F6.953.20.0.Pr , Ht Cable Set(6 Ht Cables) For Biogas Kit For Sl90 Engine Cart Part No F6.956.10.0.00 , Turbocharger Holset Hx50s F Fire Fighting Cart Part No F6.957.01.0.00 , Engine Wiring Assly: Ems907 Cart Part No F6.959.10.0.00 , Exhaust Manifold (Central Piece) Cart Part No F6.969.01.0.00 , Air Delivery Bend (For Holset Hx50 Tubocharger) Cart Part No F6.969.02.0.00 , Joint Between Air Bend & Cac-In Pipe Cart Part No F6.969.03.0.00 , Air Delivery Main Pipe Cart Part No F6.969.04.0.00 , Adaptor For Oil Inlet To Turbo Cart Part No F6.969.07.0.00 , Joint At Turbine Outlet Of Hx-50 Turbocharger Cart Part No F6.969.08.0.00 , Lube Oil Drain Pipe Assembly Cart Part No F6.969.09.0.00 , Hose: Comp Out To Air Delivery Bend Cart Part No F6.969.11.0.00 , Lub Oil Supply Pipe To Turbo Charger Cart Part No F6.969.20.0.00 , Hose: Comp. Out To Air Delivery Pipe Cart Part No F6.969.24.0.00 , Control Panel Assembly Suitable For Engine Saftey Unit Ems 907 Cart Part No F6.971.10.0.00 , Wiring Harness Assembly For 140 Kva To 200 Kva Cart Part No F6.973.10.0.00 , Hose: Air Cleaner Cart Part No F6.980.01.0.00 , Hose (From H.Exchanger Pipe To Suction ) Cart Part No F6.982.05.0.00 , Hose (From Thermostat To H.E) Cart Part No F6.982.06.0.00 , Adaptor With Flange For H. Exchanger Cart Part No F6.982.08.0.00 , Joint: Heat Exchanger Cart Part No F6.982.11.0.00 , Hose: Cac Pipe And H.E. Cart Part No F6.982.12.0.00 , Adaptor On Heat Exchanger Cart Part No F6.982.13.0.00 , Adaptor For Vent Pipe(M14x15 To 1/4) Cart Part No F6.982.14.0.00 , Heat Exchanger(S/F Fresh Water) For 6Rta And Sl90ta F.F. Engines Cart Part No F6.982.17.0.00 , Water Delivery Pipe Cart Part No F6.982.19.0.00 , Air Cleaner F.F. Engines Cart Part No F6.983.01.0.00 , Hose: Air Cleaner Cart Part No F6.983.03.0.00 , Air Cleaner Assembly Cart Part No F6.983.07.0.00 , Water Heater(Kim Hotstart, Tps 152Gt12-006, 1.5Kw, 240V) Cart Part No F6.984.01.0.00 , Bracket For Water Heater Mounting Cart Part No F6.984.05.0.00 , Terminal Block Cart Part No F6.984.10.0.00 , Hose Clamp Cart Part No F6.986.02.0.00 , Hood Assembly Cart Part No F6.986.06.0.00 , Hose Clamp Cart Part No F6.986.08.0.00 , Vacuum Indicator(25) Cart Part No F6.986.09.0.00 , Air Cleaner Primary Element Cart Part No F6.986.11.0.00 , Air Cleaner Safety Element Cart Part No F6.986.12.0.00 , Dust Cap Cart Part No F6.986.19.0.00 , Adaptor(0.25 Bsp To M16 X 1.5 ) Cart Part No F6.986.21.0.00 , Air Cleaner Assembly Kit Cart Part No F6.986.30.0.00 , Mounting Bracket Cart Part No F6.992.08.0.00 , Mounting Bracket Assembly Cart Part No F6.992.09.0.00 , Water Cooled Cac For F.F. Cart Part No F6.993.01.0.00 , Pipe(From Cac To H.E.) Cart Part No F6.993.08.0.00 , Joint: Raw Water Inlet/Outlet Cart Part No F6.993.13.0.00 , Centrifugal Filter Service Kit Cart Part No F6.999.100.0.00 , Control Panel Door Hinge 40Mm Cart Part No F6.999.109.0.Sp , Fuel Return Line Nrv Kit Cart Part No F6.999.110.0.00 , Control Panel Door Hinge 50Mm Cart Part No F6.999.111.0.Sp , Fuel Return Line Nrv Kit Cart Part No F6.999.130.0.00 , Wet Pm Kit (W/O Oil) For F6.8621..F6.9729...F6.8737.. - 6Sl1500ta Cart Part No F6.999.31.0.Sp , Wet Pm Kit (W/O Oil) For F6.3810 - 6Sl8800 Ta Cart Part No F6.999.40.0.Sp , Wet Pm Kit (W/O Oil) For F6.8625...F6.9630...F6.8733..- 6Sl1500ta Cart Part No F6.999.44.0.Sp , Wet Pm Kit (W/O Oil) For F6.8618 - 6Sl1500ta G2 Cart Part No F6.999.47.0.Sp , Wet Pm Kit (W/O Oil) For F6.2502, F6.2562, F6.2703.20, F6.3614, F6.3622, F6.3405, F6.3605, F6.3 Cart Part No F6.999.53.0.Sp , Wet Pm Kit (W/O Oil) For F6.8734 Cart Part No F6.999.72.0.Sp , Pressure Regulator First Level For 125Kvar 5201 Cart Part No F6.999.73.0.Sp , Wet Pm Kit (W/O Oil ) For F6.9860 Cart Part No F6.999.74.0.Sp , Wet Pm Kit (W/O Oil ) For F6.8802, F6.8841 Cart Part No F6.999.75.0.Sp , Wet Pm Kit (W/O Oil) For F6.3005, F6.3008, F6.3208 - 6Sl9088ta Cart Part No F6.999.78.0.Sp , Wet Pm Kit (W/O Oil) For F6.9620..., F6.8736..., F6.9822... - 6Sl8800ta Cart Part No F6.999.94.0.Sp , Wet Pm Kit (W/O Oil) For F6.2041, F6.3205, F6.2007, F6.2243, F6.2279, - 6Sl9088ta Cart Part No F6.999.95.0.Sp , Doc Catalyst (12 Dia X 5 Length, 15 G/Cft, 5/1 Pt:Pd, Fresh) Cart Part No F6.Egt4.10.0.Pr , Doc Catalyst12dia X 5Length20 G Cft5 1 Pt Pdfresh Cart Part No F6.Egt4.12.0.Pr , Scr Catalyst First Brick - Fresh (12 Dia X 7 Length, Wcl 2.75 G/In3) Cart Part No F6.Egt4.15.0.Pr , Scr Catalyst Second Brick - Fresh (12 Dia X 7 Length, 2.1 G/In3 On 5? Length, Asc 2 Cart Part No F6.Egt4.16.0.Pr , 12 V Band Clamp Machined Flange_82585245 Cart Part No F6.Egt4.22.0.Pr , 12Gasket 82602769 Cart Part No F6.Egt4.23.0.Pr , Dosing Module B444 606 555Dm2 2 6 Hole9 Bar Cart Part No F6.Egt4.24.0.Pr , Supply Module B444 606 941 (Sm 2.2 Evo Bl, 24 V, 9 Bar) Cart Part No F6.Egt4.25.0.Pr , Adblue Levelquality Temp Sensor For 45 Ltr Tank Cart Part No F6.Egt4.26.0.Pr , Exhaust Temp Sensor For Cpcb4 Cart Part No F6.Egt4.28.0.Pr , F6.Egt4.31.0.00 12 Egt System Assembly (Cpcb 4+ ) Cart Part No F6.Egt4.31.0.Sp , F6 Egt4 32 0 0012Egt System Assemblydoc20 G Cftscr2 75 G In3 Cart Part No F6.Egt4.32.0.Sp , Pipe For Turbo Oil Supply Cart Part No F6.M019.12.0.00 , Oringid 29 91 Dia 5 Mm Cart Part No F6.P008.05.0.Pr , Oringid 30 45 Dia 3 Mm Cart Part No F6.P008.07.0.Pr , 6Pk Poly-V Section Belt Cart Part No F6.P012.01.0.Pr , Fip Adaptor & Bush Assembly Cart Part No F6.P014.10.0.Pr , Fuel Filter Element 0 25 Lit Cart Part No Fa1.031.02.0.00 , Fuel Filter Assembly Cart Part No Fa1.031.20.0.00 , Bearing Bush Nt Kir Ra3 Cart Part No G.038.5.01.703 , Bearing Ig Bush: Ha394 Cart Part No G.073.5.00.703 , Main Bearing Ig Bush R1040/4K1080 Cart Part No G.584.5.00.703 , Crankcase Assembly With M B Cap Cart Part No Gp2.001.10.0.Pr , Camshaft Assembly Cart Part No Gp2.003.10.0.Pr , Cylinder Head Gasket Cart Part No Gp2.005.13.0.Pr , Rocker Lever Assembly Cart Part No Gp2.007.50.0.Pr , O Ringfor Fip Side Cover Plate Cart Part No Gp2.011.21.0.Pr , Gasket For Inlet Manifold Cart Part No Gp2.014.02.0.Pr , High Pressure Pipe Assembly Cart Part No Gp2.015.40.0.Pr , Adaptor For Housingsae4 Cart Part No Gp2.021.03.0.Pr , Adaptor For Flywheelsae 7 5 Cart Part No Gp2.021.04.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp2.021.10.0.Pr , Gasket For Rocker Cover Cart Part No Gp2.035.08.0.Pr , Fan For R550 Cart Part No Gp2.039.06.0.Pr , Fuel Pipefuel Filter To F I P Cart Part No Gp2.047.02.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No Gp2.047.06.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp2.047.08.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp2.047.09.0.Sp , Leak Off Pipepoly Amide Cart Part No Gp2.048.01.0.Pr , Lop Sensor,5V, Ratiometeric,Honeywell Cart Part No Gp2.100.01.0.Pr , Temperature Sensor,Ntc Type_Honeywell_Probe Length 10Mm Cart Part No Gp2.100.07.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp2.107.06.0.Pr , Suction Hose Cart Part No Gp2.107.12.0.Pr , Clamp For Hose Cart Part No Gp2.107.13.0.Pr , Rubber Sleeve For Hose Cart Part No Gp2.107.14.0.Pr , Radiator Assembly For 2R550 Cart Part No Gp2.107.25.0.Pr , Fuel Tank Unit For 2R550exports Cart Part No Gp2.108.08.0.Pr , Fuel Hose From Fuel Tank To Pump Cart Part No Gp2.108.26.0.Pr , Fuel Pipefrom Pump To Feedpump Cart Part No Gp2.108.27.0.Pr , Anti Vibration Mount Cart Part No Gp2.110.07.0.Pr , Engine Wiring Harness For 2R550 10 12Kva Engine With Ag48 And Kg645c Cart Part No Gp2.225.50.0.Pr , Hex. Head Screw (For M.B. Cap) Cart Part No Gp3.001.05.0.Pr , Cam Shaft Bushna Tc Cart Part No Gp3.001.06.0.Pr , Crankcase Assemblywith M Bcap Cart Part No Gp3.001.10.0.Pr , Hollow Dowel Dia 11 (Gear End) Cart Part No Gp3.001.11.0.Pr , Socket Head Grub Screw M16x2 Cart Part No Gp3.001.13.0.Pr , Oil Spray Nozzle Cart Part No Gp3.001.14.0.Pr , Hollow Dowel Dia 12 (For Cylinder Head) Cart Part No Gp3.001.15.0.Pr , Threaded Adaptor(For Oil Filter) Cart Part No Gp3.001.19.0.Pr , Pin (For Banjo) Cart Part No Gp3.001.26.0.00 , Plugfor Banjo Cart Part No Gp3.001.27.0.Pr , Banjo Boltfor Oil Supply Cart Part No Gp3.001.28.0.Pr , Banjo Bolt For Header Cart Part No Gp3.001.29.0.Pr , Banjo Boltfor Turbo Oil Supply Pipe Cart Part No Gp3.001.33.0.Pr , Carnkcase Assemblywith M Bcap Cart Part No Gp3.001.50.0.Pr , Crank Gear Cart Part No Gp3.002.02.0.Pr , Crankshaft Assemblywith Crank Gear Cart Part No Gp3.002.10.0.Pr , Cam Gear Cart Part No Gp3.003.02.0.Pr , Thrust Plate (Cam Shaft) Cart Part No Gp3.003.03.0.Pr , Camtone Wheel For Crdi Cart Part No Gp3.003.07.0.Pr , Camshaft Assembly Cart Part No Gp3.003.10.0.Pr , Piston Assembly Cart Part No Gp3.004.10.0.Pr , Piston Assembly Cart Part No Gp3.004.130.0.Pr , Connecting Rod Asslywith Small End Bush Cart Part No Gp3.004.20.0.Pr , Small End Bushbimetal Bearings Ltd Cart Part No Gp3.004.22.0.Pr , Connecting Rod Bearing Upperbimetal Bearings Ltd Cart Part No Gp3.004.23.0.Pr , Connecting Rod Bearing Lowerbimetal Bearings Ltd Cart Part No Gp3.004.24.0.Pr , Cylinder Head Bolt Cart Part No Gp3.005.08.0.Pr , Engine Valve Intake4 Valve Cart Part No Gp3.005.11.0.Pr , Cylinder Head Sub Assembly (With Valve Seats & Inserts) Cart Part No Gp3.005.110.0.Pr , Engine Valve Exhaust4 Valve Cart Part No Gp3.005.12.0.Pr , Valve Stem Seal Cart Part No Gp3.005.17.0.Pr , Cylinder Head Gasket Cart Part No Gp3.005.19.0.Pr , Cylinder Head Assembly With Valves And Springs Cart Part No Gp3.005.30.0.Pr , Valve Guide With Snap Ring Assembly Cart Part No Gp3.005.50.0.00 , Pushrod (2 Valve, Welded) Cart Part No Gp3.006.01.0.Pr , Tappet Cart Part No Gp3.006.04.0.Pr , Rocker Lever Assembly Complete Cart Part No Gp3.007.50.0.Pr , Rocker Lever Assembly Complete Cart Part No Gp3.007.60.0.Pr , Relief Valve Cart Part No Gp3.008.08.0.Pr , Shaft For Lop Intermediate Gear Cart Part No Gp3.008.11.0.Pr , Washer (For L. O. P. Intermediate Gear) Cart Part No Gp3.008.12.0.Pr , O Ringfor Lub Oil Pump Cart Part No Gp3.008.13.0.Pr , Socket Head Grub Screw M14 Cart Part No Gp3.008.15.0.Pr , Lop With Relife Valve Assembly Cart Part No Gp3.008.50.0.Pr , Intermediate Gear Support Cart Part No Gp3.009.03.0.Pr , Thrust Washer For Intermediate Gear Cart Part No Gp3.009.04.0.Pr , Fip Gear Cart Part No Gp3.009.05.0.Pr , Adapter (For Fuel Pump Gear) Cart Part No Gp3.009.06.0.Pr , Sub Assembly Of Intermediate Gear Cart Part No Gp3.009.10.0.Pr , Gear Cover Cart Part No Gp3.010.01.0.Pr , Fip Cover Plate Cart Part No Gp3.010.03.0.Pr , O Ring For Fip Cover Plate Cart Part No Gp3.010.06.0.Pr , Oil Seal Cart Part No Gp3.010.09.0.Pr , Flanged Bolt (M6x1x070) Cart Part No Gp3.010.13.0.Pr , Gear Cover Cart Part No Gp3.010.14.0.Pr , Cam Housing (For Fuel Pump) Cart Part No Gp3.011.01.0.Pr , Cam Shaft (For F.I.P.) Cart Part No Gp3.011.02.0.Pr , Fuel Pump Cart Part No Gp3.011.06.0.Pr , Pin (For Link) Cart Part No Gp3.011.08.0.Pr , Dowel Pin (Rack Side) Cart Part No Gp3.011.102.0.00 , Oil Supply Pipe (Crankcase To F.I.P.) Cart Part No Gp3.011.12.0.Pr , Front Cover (For Fip) Cart Part No Gp3.011.13.0.Pr , O Ring (Front Cover Fip) Cart Part No Gp3.011.14.0.Pr , Stop Lever Cart Part No Gp3.011.16.0.Pr , Arm (Stop Lever) Cart Part No Gp3.011.17.0.Pr , Oringside Cover Fip Cart Part No Gp3.011.21.0.Pr , Back Cover ( For Fip) Cart Part No Gp3.011.22.0.Pr , O Ring (Back Cover Fip) Cart Part No Gp3.011.23.0.Pr , Bracket (For Fip) Cart Part No Gp3.011.24.0.Pr , Cover (Feed Pump) Cart Part No Gp3.011.25.0.Pr , O Ring (Feed Pump Cover) Cart Part No Gp3.011.26.0.Pr , Drain Plug For F.I.P. Cart Part No Gp3.011.27.0.Pr , O-Ring (For Drain Plug) Cart Part No Gp3.011.28.0.Pr , Side Cover (For Fip) Cart Part No Gp3.011.29.0.Pr , Stud (For F.I.P.) Cart Part No Gp3.011.31.0.Pr , Stud (For Side Cover Plate) Cart Part No Gp3.011.32.0.Pr , O Ring (For Stop Lever Shaft) Cart Part No Gp3.011.34.0.Pr , Lock Nut (For F.I.P.) Cart Part No Gp3.011.36.0.Pr , Cylindrical Roller Bearing-Nu205ecp (D-52, D-25,B-15) Cart Part No Gp3.011.38.0.Pr , Stud For F.I.P(M8x1.25) Cart Part No Gp3.011.39.0.Pr , Cb18 Fuel Pump Cart Part No Gp3.011.41.0.Pr , Fuel Pump Assembly Cart Part No Gp3.011.410.0.Pr , Oil Supply Pipecrankcase To F I P Cart Part No Gp3.011.44.0.Pr , Linear Actuator Cart Part No Gp3.011.47.0.Pr , Shaft (For Stop Lever Arm) Cart Part No Gp3.011.51.0.Pr , Torsional Spring Cart Part No Gp3.011.52.0.Pr , Spacer For Stop Lever Cart Part No Gp3.011.53.0.Pr , Fuel Pump Assembly Cart Part No Gp3.011.530.0.Pr , Oil Seal Housing For Fip (20X52x10) Cart Part No Gp3.011.59.0.00 , Fuel Pump Cart Part No Gp3.011.67.0.Pr , Pin (For Actuator Side) Cart Part No Gp3.011.95.0.Pr , Pin (For Fip Rack Side) Cart Part No Gp3.011.96.0.00 , Pin (For Link) Cart Part No Gp3.011.97.0.Pr , Link (Electronic Governor) Cart Part No Gp3.011.98.0.Pr , O Ring For Hydraulic Pump Adaptor Cart Part No Gp3.012.03.0.Pr , Oil Filling Adapter Cart Part No Gp3.012.05.0.Pr , O-Ring(For Oil Filling Cap) Cart Part No Gp3.012.07.0.Pr , O-Ring(For Breather Adaptor) Cart Part No Gp3.012.09.0.Pr , Cover Plate(For Gear Casing Hydraulic Side) Cart Part No Gp3.012.12.0.Pr , Gear Casingfor Mechanical F I P Cart Part No Gp3.012.13.0.Pr , Cover Plate For Gear Casing Cart Part No Gp3.012.14.0.Pr , Rotary Make Feed Pump 100Lph Cart Part No Gp3.012.87.0.Pr , Injector Clamp Cart Part No Gp3.013.04.0.00 , P Type Injector For R550 Engine Cart Part No Gp3.013.14.0.Pr , P-Type Injector For R550 Engine Cart Part No Gp3.013.25.0.Pr , P-Type Injector For R550 Engine Cart Part No Gp3.013.32.0.Pr , Intake Manifold Cart Part No Gp3.014.01.0.Pr , Gasket For Intake Manifold Cart Part No Gp3.014.02.0.Pr , Intake Manifold Cover Cart Part No Gp3.014.03.0.Pr , Gasket For Intake Manifold Cover Cart Part No Gp3.014.04.0.Pr , Joint For Intake Adaptor Cart Part No Gp3.014.07.0.Pr , Spacer Between Inlet Manifold & Air Intake Adaptor Cart Part No Gp3.014.11.0.Pr , Gasket For Intake Manifold Cart Part No Gp3.014.13.0.Pr , Stud (For Intake Manifold) Cart Part No Gp3.014.14.0.Pr , R550 Flange Heater With Same Side Connection Studs Cart Part No Gp3.014.16.0.Pr , High Pressure Pipefor Cyl 3 Cart Part No Gp3.015.100.0.Pr , High Pressure Pipefip To Common Rail Cart Part No Gp3.015.120.0.Pr , High Pressure Pipefip To Common Rail Cart Part No Gp3.015.130.0.Pr , High Pressure Pipe Assembly Cart Part No Gp3.015.160.0.Pr , High Pressure Pipe Assembly Cart Part No Gp3.015.40.0.Pr , High Pressure Pipefor Cyl 1 Cart Part No Gp3.015.70.0.Pr , Hp Pipeintegral Sleeve Assly Cart Part No Gp3.015.90.0.Pr , Rear Oil Seal Housing Cart Part No Gp3.016.01.0.Pr , Oil Seal Cart Part No Gp3.016.02.0.Pr , O Ring For Oil Seal Housing Cart Part No Gp3.016.04.0.Pr , O Ringfor Suction Tube Adaptor Cart Part No Gp3.017.07.0.Pr , Suction Tube Assembly Cart Part No Gp3.017.12.0.Pr , Lub Oil Sump Sub Assembly Cart Part No Gp3.019.10.0.Pr , Flywheel Housing Sae4 Width - 105 Cart Part No Gp3.020.01.0.Pr , Cover Plate For Sensor Cart Part No Gp3.020.06.0.Pr , Timing Pointer Assembly Cart Part No Gp3.020.08.0.Pr , Flywheel Housing Sae4-Width 105 Cart Part No Gp3.020.09.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp3.021.10.0.Pr , Starter Ring Cart Part No Gp3.021.11.0.Pr , Flywheel Starter Ring Assembly Cart Part No Gp3.021.110.0.Pr , Flywheel Bolt (M12x1.25X30) Cart Part No Gp3.021.12.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp3.021.50.0.Pr , Startor Cart Part No Gp3.022.01.0.Pr , Header Cart Part No Gp3.024.02.0.Pr , O Ring (Dia 19X2) Cart Part No Gp3.024.03.0.Pr , O Ring (Dia 61X3) Cart Part No Gp3.024.04.0.Pr , Oil Filter Cart Part No Gp3.024.05.0.Pr , Dipstick Assemblywith Knob Cart Part No Gp3.025.10.0.Pr , Gasket For Exhaust Manifold Cart Part No Gp3.029.02.0.Pr , Gasketfor Turbo To Exhaust Manifold Cart Part No Gp3.029.06.0.Pr , Spacer (For Exhaust Manifold) Cart Part No Gp3.029.07.0.Pr , Gasket Exhaust Manifold To Egr Cooler Cart Part No Gp3.029.09.0.Pr , Gasketfor Turbo To Exhaust Manifold Cart Part No Gp3.029.11.0.Pr , Spacerfor Exhaust Manifold Cart Part No Gp3.029.12.0.Pr , Exhaust Manifold Cart Part No Gp3.029.15.0.Pr , Exhaust Manifold Cart Part No Gp3.029.18.0.Pr , Turbo Charger For Tc Versioncpcb Ii Cart Part No Gp3.030.13.0.Pr , Improved Efficiency Turbocharger For 3R550ta (Mechanical) Cpcb 4+ 25.5Hp@1500R Cart Part No Gp3.030.14.0.Pr , Turbocharger Cart Part No Gp3.030.15.0.Pr , Alternator Support Bracket Ch (On Cylinder Head) Cart Part No Gp3.031.01.0.Pr , Alternator Support Bracket Cart Part No Gp3.031.02.0.Pr , Alternator Pulley (P.C.D.68) Cart Part No Gp3.031.05.0.Pr , Water Pump Sleeve Cart Part No Gp3.032.07.0.Pr , O Ringfor Water Pump Sleeve Cart Part No Gp3.032.08.0.Pr , Water Pump Joint Cart Part No Gp3.032.11.0.Pr , Water Pump Assembly Cart Part No Gp3.032.50.0.Pr , Washer (For Crank Pulley Bolt) Cart Part No Gp3.033.02.0.Pr , Crank Pulley (Pcd 110) Cart Part No Gp3.033.04.0.Pr , Water Pump Pulley (Pcd 86) Cart Part No Gp3.033.08.0.Pr , Poly V-Belt Cart Part No Gp3.033.11.0.Pr , Thermostat Cover Cart Part No Gp3.034.01.0.Pr , Gasket For Thermostat Cover Cart Part No Gp3.034.02.0.Pr , Thermostat Element Cart Part No Gp3.034.03.0.Pr , Rocker Cover Cart Part No Gp3.035.01.0.Pr , Blow By Adaptor (For Closed Breather System) Cart Part No Gp3.035.02.0.Pr , Gromet For Rocker Cover Bolt Cart Part No Gp3.035.04.0.Pr , Cap For Rocker Cover Bolt Gromet Cart Part No Gp3.035.05.0.Pr , Oil Filling Cap (Plastic) Cart Part No Gp3.035.06.0.Pr , Sealing Washer (For Oil Filling Cap) Cart Part No Gp3.035.07.0.Pr , Gasket For Rocker Cover Cart Part No Gp3.035.08.0.Pr , Bolt For Rocker Cover Cart Part No Gp3.035.09.0.Pr , Oil Separator Cart Part No Gp3.035.11.0.Pr , O-Ring (For Closed Breather Adaptor) Cart Part No Gp3.035.12.0.Pr , Gasket For Rocker Cover Cart Part No Gp3.035.14.0.Pr , O Ringfor Rocker Cover Cart Part No Gp3.035.15.0.Pr , Rocker Cover Cart Part No Gp3.035.16.0.Pr , Radiator Pipe Cart Part No Gp3.035.36.0.Pr , Adaptorm12x1 5X11lfor Water Heater Hose Cart Part No Gp3.035.38.0.Pr , Breather Hose Cart Part No Gp3.036.02.0.Pr , Air Cleaner Assembly Cart Part No Gp3.037.18.0.Pr , Air Cleaner Mounting Bracket Cart Part No Gp3.037.34.0.Pr , Air Cleaner Hose Cart Part No Gp3.037.37.0.Pr , Hose For Air Cleaner Cart Part No Gp3.037.38.0.Pr , Bracket For Air Cleaner Cart Part No Gp3.037.39.0.Pr , Dry Type Air Cleaner Assly For R550 Cart Part No Gp3.037.40.0.Pr , Air Cleaner Hose Cart Part No Gp3.037.43.0.Pr , Air Cleaner Hose To Turbo Cart Part No Gp3.037.78.0.Pr , Hose For Air Suction Cart Part No Gp3.037.98.0.Pr , Joint For Exhaust System Cart Part No Gp3.038.04.0.Pr , Expansion Bellow With Pipe From Manifold To Silencer (Gp3-15Kva) Cart Part No Gp3.038.08.0.Pr , Silencer For 3R550 2R550 Cart Part No Gp3.038.10.0.Pr , Exhaust Pipe (Bellow Out To Silencer I Cart Part No Gp3.038.103.0.Pr , Silencer Assembly Cart Part No Gp3.038.15.0.Pr , Joint Exhaust Bend Cart Part No Gp3.038.16.0.Pr , Exhaust Pipe With Bellow (Turbo Out To Sil In) Cart Part No Gp3.038.22.0.Pr , Exhaust Pipe With Bellow (Exhaust Manifold To Silencer) Cart Part No Gp3.038.51.0.Pr , Joint Cart Part No Gp3.038.66.0.Pr , Exhaust Pipe With Bellow (3R550tc) Cart Part No Gp3.038.67.0.Pr , Exhaust Pipe (Turbo Out To Bellow In) Cart Part No Gp3.038.99.0.Pr , Fan For R550 Radiatordia 380Mm Cart Part No Gp3.039.04.0.Pr , Spacer For Fan Cart Part No Gp3.039.05.0.Pr , Fan For R550 Radiator Cart Part No Gp3.039.06.0.Pr , Lifting Hook Cart Part No Gp3.040.01.0.Pr , Gp3.041.07.0.Pr_Pipe (Turbo Side) Cart Part No Gp3.041.07.0.Pr , Hose Cart Part No Gp3.041.08.0.Pr , Cac Hosecold Side Cart Part No Gp3.042.02.0.Pr , Cac Hosecold Side Cart Part No Gp3.042.05.0.Pr , Cac Hosehot Side Cart Part No Gp3.043.02.0.Pr , Hoseturbo Side Cart Part No Gp3.043.08.0.Pr , Hoseturbo Side Cart Part No Gp3.043.14.0.00 , Cac Pipe ( Hot Side) Cart Part No Gp3.043.15.0.00 , Cac Hoseradiator Side Cart Part No Gp3.043.16.0.Pr , Packing Foot For R550 Cart Part No Gp3.045.76.0.Pr , Engine Mounting Foot For R550 Cart Part No Gp3.045.79.0.Pr , Engine Mounting Foot For R550 Cart Part No Gp3.045.81.0.Pr , Spacer Between Engine Foot Crank Case Cart Part No Gp3.045.82.0.Pr , Gasketfor Turbo To Oil Drain Pipe Cart Part No Gp3.046.01.0.Pr , Adaptor (For Turbo Oil Inl Cart Part No Gp3.046.08.0.Pr , O Ring For Turbo Oil Suppy Pipe Adaptor Cart Part No Gp3.046.13.0.Pr , Drain Pipe Assy (For Turbo Charger) Cart Part No Gp3.046.14.0.Pr , Turbo Drain Pipe Assy (For Turbo Charger) Cart Part No Gp3.046.19.0.Pr , Adaptor With Hose Tail For Sump Drain Cart Part No Gp3.046.22.0.Pr , Turbo Oil Supply Pipe (Turbo Side) Cart Part No Gp3.046.29.0.Pr , Turbo Oil Supply Pipe (Crankcase Side) Cart Part No Gp3.046.31.0.Pr , Turbo Oil Supply Pipecrankcase Side Cart Part No Gp3.046.32.0.Pr , Fuel Filter Assembly. Cart Part No Gp3.047.01.0.Pr , Fuel Pipefuel Filter To F I P Cart Part No Gp3.047.02.0.Pr , Filter To Fip Cart Part No Gp3.047.09.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No Gp3.047.11.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp3.047.14.0.Sp , Fuel Filter Cart Part No Gp3.047.16.0.Pr , Spinon Fuel Filter Cart Part No Gp3.047.55.0.Pr , Leak Off Pipepolyamide Cart Part No Gp3.048.01.0.Pr , Leak Off Pipe Assembly Cart Part No Gp3.048.05.0.Pr , Leak Off Pipe Assembly For Fip Side Cart Part No Gp3.048.11.0.Pr , Common Rail Cart Part No Gp3.049.01.0.Pr , Mixer (Foregr ) Cart Part No Gp3.050.01.0.Pr , Hose Mixer To Throttle Body Cart Part No Gp3.050.02.0.Pr , Mixer Plate ( For Egr) Cart Part No Gp3.050.03.0.Pr , Gasketbetween Egr Valveegr Pipe Cart Part No Gp3.050.04.0.Pr , Gasket Between Egr Mixer And Egr Valve Cart Part No Gp3.050.05.0.Pr , Stud (For Egr Valve) Cart Part No Gp3.050.06.0.Pr , Stud (For Egr Valve) Cart Part No Gp3.050.07.0.Pr , Hose (Mixer For Egr To Pipe) Cart Part No Gp3.050.09.0.Pr , Hose Egr Valveto Crankcase Cart Part No Gp3.050.11.0.Pr , Hoseegr Valve To Cy Head Cart Part No Gp3.050.12.0.Pr , Between Egr Valve And Egr Pipe Cart Part No Gp3.050.14.0.Pr , Gp3.050.15.0.Pr_Hose Cart Part No Gp3.050.15.0.Pr , Mixer (Foregr ) Cart Part No Gp3.050.18.0.Pr , Intake Pipe Cart Part No Gp3.050.19.0.Pr , Mixer Plate Cart Part No Gp3.050.21.0.Pr , O Ring Cart Part No Gp3.050.22.0.Pr , Bracket For Hose Cart Part No Gp3.050.23.0.Pr , Bracket For Hose Cart Part No Gp3.050.24.0.Pr , Egr Pipe Cart Part No Gp3.054.02.0.Pr , Hose Egr Valve Water Inlet Cart Part No Gp3.055.07.0.Pr , Hose Egr Valve Water Outlet Cart Part No Gp3.055.08.0.Pr , Egr Cooler 5 Kw Cart Part No Gp3.055.13.0.Pr , Diesel Oxidation Catalystdocgp3 056 01 Cart Part No Gp3.056.01.0.Spr , Gasket Between Doc Pipe And Doc Cart Part No Gp3.056.05.0.Pr , Expansion Bellow Cart Part No Gp3.056.07.0.Pr , Heat Shield Cart Part No Gp3.058.03.0.Pr , Hose For Breather System Cart Part No Gp3.062.02.0.Pr , Hose For Breather Cart Part No Gp3.062.06.0.Pr , Charging Alternetor Cart Part No Gp3.100.01.0.Pr , 3R550 Engine Ecuag48 Cart Part No Gp3.100.02.0.Pr , Ecu (Ag48), For Pg Specific Application Cart Part No Gp3.100.03.0.Pr , Ecu Mounting Bracket Cart Part No Gp3.100.05.0.Pr , 3R550 Engine Ecu (Ag48) Cart Part No Gp3.100.21.0.Pr , Support Plate Cart Part No Gp3.107.01.0.Pr , U Clamp Cart Part No Gp3.107.02.0.Pr , Hose For Radiator Cart Part No Gp3.107.04.0.Pr , Hose For Radiator Cart Part No Gp3.107.05.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp3.107.06.0.Pr , Suction Hose Cart Part No Gp3.107.12.0.Pr , Support Plate Cart Part No Gp3.107.18.0.Pr , Radiator For R550 Genset Cart Part No Gp3.107.23.0.Pr , Pipe (Radiator To Pump Inlet) Cart Part No Gp3.107.34.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp3.107.36.0.Pr , Radiator Assembly For R550 Cart Part No Gp3.107.97.0.Pr , Fuel Pipe From Pre Filter To Feed Pump Cart Part No Gp3.108.01.0.Pr , Electric Feed Pump And Fuel Filter Mounting Bracket Cart Part No Gp3.108.05.0.Pr , Fuel Pipe From Tank To Filter Cart Part No Gp3.108.06.0.Pr , Fuel Tank Unit S/F 95 Effective Tank Height Cart Part No Gp3.108.07.0.Pr , Fuel Inlet Pipe (Tank To Pump) Cart Part No Gp3.108.101.0.Pr , Fuel Inlet Pipe (Tank To Feed Pump) Cart Part No Gp3.108.102.0.Pr , Adaptorm16 X 1 5 To M22 X 1 5 Cart Part No Gp3.108.14.0.Pr , Fuel Pipe From Tank To Pre Filter Cart Part No Gp3.108.141.0.Pr , Fuel Pipe From Pre Filter To Main Filter Cart Part No Gp3.108.142.0.Pr , Adaptor (M22x1.5 & M14x1.5) Cart Part No Gp3.108.149.0.Pr , Top Clampfor Electric Pump Cart Part No Gp3.108.16.0.Pr , Lower Clamp (For Electric Pump) Cart Part No Gp3.108.17.0.Pr , Fuel Pipe From Tank To Pump Cart Part No Gp3.108.19.0.Pr , Fuel Pipe Electric Pump To Tank Unit Cart Part No Gp3.108.56.0.Pr , Fuel Pipefrom Tank To Pump Cart Part No Gp3.108.57.0.Pr , Anti Vibration Mount Cart Part No Gp3.110.07.0.Pr , Can Display Unit For R550 Cart Part No Gp3.119.05.0.Pr , Kg645 C Controller Unit R550 (Sp-3 Hardware 12V) Cart Part No Gp3.210.17.0.Pr , Battery Cable R550 Cart Part No Gp3.210.30.0.Pr , Engine Wiring Harness For 3R550ta Crdi Cpcb4 Cart Part No Gp3.211.10.0.Pr , Control Panel Electrical Schematic For 25Kva 1 Ph 3R550 Cpcb4 Cart Part No Gp3.211.80.0.Pr , 48V Terminal Box Assembly Cart Part No Gp3.212.10.0.Pr , Electrical Scheamatic For 15Kva3ph 3R550 With Kg645c Cart Part No Gp3.221.40.0.Pr , Electrical Scheamatic For 15Kva1ph 3R550 With Kg645c Cart Part No Gp3.221.50.0.Pr , Engine Wiring Harness 3R550 Engine With Ag48 And Kg645c Cart Part No Gp3.221.60.0.Pr , Engine Wiring Harness 3R550 Engine With Ag48 And Kg645c Cart Part No Gp3.221.80.0.Pr , Control And Power Panel Assembly For 25 Kva 1Ph Cpcb4 Cart Part No Gp3.222.30.0.Pr , Control Panel Assembly For 15 Kva 3Ph Cpcb4 Cart Part No Gp3.227.60.0.Pr , Control Panel Assembly For 15Kva 1Ph Cpcb4 Cart Part No Gp3.228.20.0.Pr , Control Panel Assembly Cart Part No Gp3.229.30.0.Pr , Super Capacitor To Starter Harness Cart Part No Gp3.230.30.0.Pr , Mccb 125A 2P 25Ka Cart Part No Gp3.230.41.0.Pr , Super Capacitor Module 48V Cart Part No Gp3.230.61.0.Pr , Procom Controller ,Model-Econ-Abt-Rel Cart Part No Gp3.230.62.0.Pr , Fuel Level Sensor Cart Part No Gp3.230.65.0.Pr , Flexible Coupling Disc Kg 42.3 Sae 7.5_Ag424059 R00 Cart Part No Gp3.230.67.0.Pr , Cold Start Kit Main Assembly For L2 Level Application(3R550) Cart Part No Gp3.232.50.0.Sp , Cold Start Sub Assembly 3R550 Cart Part No Gp3.233.50.0.Pr , Water Heater Connections Metal Pipe Cart Part No Gp3.478.01.0.Pr , Rubber Hosefor Water Heater Cart Part No Gp3.478.04.0.Pr , Clamping Bracket Cart Part No Gp3.507.03.0.Pr , 1500 Hrs C Check Maintenance Kit Gp3 8601Gp3 1021Gp3 8604 Cart Part No Gp3.860.01.0.Sp , K350 Avr Cart Part No Gp3.901.22.0.00 , Koel Alternator 15 Kva 3Ph 415V 0 8P F 50 Hzsae 47 5 Frame Kg40 E Cart Part No Gp3.901.62.0.Pr , Koel Green Alternator 20Kva 3Ph 415V 50Hz Sae4 7 5 Cart Part No Gp3.901.63.0.Pr , Koel Green Alternator 25Kva 3Ph 415V 50Hz Sae4 7 5 Cart Part No Gp3.901.82.0.Pr , Terminal Bar 2 Stud Cart Part No Gp3.902.24.0.Pr , Battery Cable 50 Sqmm 1350Mm Cart Part No Gp3.913.60.0.Pr , Water Jacket Heater Harness Cart Part No Gp3.913.70.0.Pr , Piston Ring Set Cart Part No Gp3.999.02.0.Sp , Inlet Exhaust Valve Pair Cart Part No Gp3.999.03.0.Sp , Main Bearing Pair R550 Cart Part No Gp3.999.10.0.Sp , Fip Timing Tool For F Series Cart Part No Gp3.999.107.0.Esp , Box Type Fip Spanner 135Mm For 3R550 Cart Part No Gp3.999.109.0.Sp , Thrust Washer Set R550 Cart Part No Gp3.999.11.0.Sp , S Type Fip Spanner For 2R550 & 3R550 Cart Part No Gp3.999.110.0.Sp , Puller For Fip Hub Removal 2R550 & 3R550 Cart Part No Gp3.999.111.0.Sp , Connecting Rod Bearing R550 Cart Part No Gp3.999.12.0.Sp , Piston Assembly For Gp3.1009, Engine Cart Part No Gp3.999.18.0.Sp , Wet Pm Kit (W/O Oil) For Gp3.8006.Pb - 3R550nag1 Cart Part No Gp3.999.25.0.Sp , Wet Pm Kit (W/O Oil ) For Gp3.8601 Cart Part No Gp3.999.52.0.Sp , Wet Pm Kit (W/O Oil) For Gp3.8006 - 3R550nag1 Cart Part No Gp3.999.78.0.Sp , Bracket For R550 (3 Cyl Engine) Cart Part No Gp3.999.92.0.Sp , Valve Bridge4 Valve Cart Part No Gp4.005.11.0.00 , Oil Cooler Cart Part No Gp4.023.01.0.Pr , O Ring For Oil Cooler Cart Part No Gp4.023.02.0.Pr , Oil Cooler Nine Plate Cart Part No Gp4.023.03.0.Pr , Oil Separator Cart Part No Gp4.035.11.0.Pr , Con Rod Bearing: Pair Ra3 Cart Part No H.038.4.00.003 , Con Rod Bearing Pair: Ra3 Cart Part No H.038.4.00.013 , Con Rod Bearing Pair: Ra3 Cart Part No H.038.4.00.023 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.003 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.013 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.023 , Bearing C/R Cart Part No H.073.4.00.033 , Con Rod Brg Ha394 Std Pair Cart Part No H.073.4.10.003 , Con Rod Bearing Ha3940.25 Pair Cart Part No H.073.4.10.013 , Con Rod Bearing: Ha394 020 U/S Pair Nick Cart Part No H.073.4.10.023 , Bearing C Rkir Ha 3940 75 Pair Nick Cart Part No H.073.4.10.033 , Bearing C/Rkir Ha 394, 1.00 Pair, (Nick) Cart Part No H.073.4.10.043 , Connecting Rod Bearing Pair Cart Part No H.547.4.00.003 , Con Rod Bearing Pair Cart Part No H.553.4.00.003 , O Ring For Side Cover Plate Cart Part No K12.001.18.0.Pr , O Ring For Sealing Plug Cart Part No K12.001.21.0.Pr , O Ring For Cam Cover Cart Part No K12.001.25.0.Pr , Gasket For Top Cover Plate Cart Part No K12.001.27.0.Pr , Dowel Pin For Cylinder Head Cart Part No K12.001.31.0.Pr , O Ring For Relief Valve Cover Plate Cart Part No K12.001.33.0.Pr , Oil Spray Nozzle Cart Part No K12.001.61.0.Pr , O Ring Cart Part No K12.002.02.0.Pr , Scraper Ring Cart Part No K12.002.03.0.Pr , Cylinder Liner Assembly Cart Part No K12.002.10.0.Pr , O Ring For Crank Gear Cart Part No K12.003.05.0.Pr , Connecting Rod Bolt Cart Part No K12.005.02.0.Pr , Piston Ring Set For K4300 Cart Part No K12.005.03.0.Sp , Circlip Cart Part No K12.005.08.0.Pr , Piston Assembly Cart Part No K12.005.10.0.Pr , Conrod Bearing Upper Half Cart Part No K12.005.11.0.Pr , Conrod Bearing Lowerhalf Cart Part No K12.005.12.0.Pr , Push Rod Assembly Cart Part No K12.006.40.0.Pr , Fulcrum Lever Assembly Cart Part No K12.006.50.0.Pr , Inlet Valve Cart Part No K12.007.02.0.Pr , Exhaust Valve Cart Part No K12.007.03.0.Pr , Valve Spring Outer Cart Part No K12.007.04.0.Pr , Valve Spring Inner Cart Part No K12.007.06.0.Pr , Main Cylinder Head Bolt Cart Part No K12.007.07.0.Pr , Inlet Valve Seat Insert (Semifinish) Cart Part No K12.007.08.9.Pr , Exhaust Valve Seat Insert(Semifinish) Cart Part No K12.007.09.9.Pr , Valve Guide - Semifinish Cart Part No K12.007.11.9.Pr , Bridge For Rocker Arm Cart Part No K12.007.13.0.Pr , Valve Rotator Cart Part No K12.007.14.0.Pr , Fire Ring3 Thkfor Cylinder Head Gasket Cart Part No K12.007.15.0.Pr , Fire Ring3 25 Thkfor Cylinder Head Gasket Cart Part No K12.007.16.0.Pr , Nozzle Clamp Cart Part No K12.007.18.0.Pr , Cup Washer For Nozzle Clamp Cart Part No K12.007.21.0.Pr , Valve Collet Cart Part No K12.007.24.0.Pr , Auxilary Cylinder Head Bolt Cart Part No K12.007.26.0.Pr , Cylinder Head Gasketfor 3 Thk Fire Ring Cart Part No K12.007.28.0.Pr , Nut For Feed Tube Cart Part No K12.007.32.0.Pr , Rocker Lever Assemblycomplete Cart Part No K12.008.70.0.Pr , Gasket For Rocker Cover Cart Part No K12.009.02.0.Pr , O Ringfor Gear Casing Cart Part No K12.010.03.0.Pr , O Ring For Intermediate Double Gear Support Cart Part No K12.011.02.0.Pr , Lop Assembly With Geargear Ratio 1 4 Cart Part No K12.012.170.0.Pr , O Ring For Sea Water Pump Cover Cart Part No K12.013.05.0.Pr , O Ring For Fuel Pump Cover Plate Cart Part No K12.013.07.0.Pr , O Ringcs 2 X 11 Id For Water Pump Sleeve Assy Cart Part No K12.013.12.0.Pr , O Ring For Fip Gear Support Cover Cart Part No K12.013.19.0.Pr , O Ring Bw Housing And Fornt Cover Cart Part No K12.014.08.0.Pr , O Ringfor Water Pump Suction Pipe Cart Part No K12.014.09.0.Pr , Water Pump Assemblytaper Shaft Cart Part No K12.014.60.0.Pr , Gasket For Water Pump Volute Cart Part No K12.015.02.0.Pr , O Ring For Suction Pipe Cover Plate Cart Part No K12.016.03.0.Pr , O Ring For Thermostat Pipe Sleeve Cart Part No K12.016.05.0.Pr , Suction Pipe For Water Pump Cart Part No K12.016.06.0.Pr , O-Ring For Water Pump Suction Pipe Volute Side Cart Part No K12.016.07.0.Pr , O-Ring For Water Pump Suction Cart Part No K12.016.08.0.Pr , Thermostat Cart Part No K12.017.02.0.Pr , Gasket Between Thermostat Housing And Gear Casing Cart Part No K12.017.06.0.Pr , O Ringfor Thermostat Cart Part No K12.017.07.0.Pr , Seal Ring (For Thermostat Element) Cart Part No K12.017.09.0.Pr , Housing For Thermostat Out Cart Part No K12.017.11.0.Pr , O Ring For Thermostat Out Adaptor Cart Part No K12.017.12.0.Pr , Gasketfor Thermostat Housing Cart Part No K12.017.13.0.Pr , Filter Header O Ring Cart Part No K12.018.02.0.Pr , O Ring For Sleevefor Oil And Cooler Header Cart Part No K12.018.05.0.Pr , Gasketfor Lub Oil Header Cart Part No K12.018.06.0.Pr , Gasket For Oil Cooler Header Cover Cart Part No K12.018.09.0.Pr , Oil Cooler Cart Part No K12.018.12.0.Pr , O Ring For Oil Cooler Cart Part No K12.018.13.0.Pr , Dome Nut O Ringfor Oil Cooler Cart Part No K12.018.15.0.Pr , Lube Filter, Spin On Cart Part No K12.018.27.0.Pr , Adaptorfor Bypass Filter Cart Part No K12.019.02.0.Pr , Gasketfor Bypass Filter Cart Part No K12.019.03.0.Pr , Fuel Injection Pump Lhs Cart Part No K12.020.10.0.Pr , Fip For K12 N16299m Rhs From Gear End Cart Part No K12.021.10.0.Pr , Fuel Filter Assembly Cart Part No K12.022.02.0.Pr , Bracket For Fuel Filter Cart Part No K12.022.06.0.Pr , Fuel Filter Spin On Cart Part No K12.022.07.0.Pr , Gasket For Cover Plate Cart Part No K12.023.03.0.Pr , O Rings C 4 X 145 Id Cart Part No K12.023.05.0.Pr , Gasketfor Inlet Manifold Cart Part No K12.023.13.0.Pr , Cac Adaptorrhs From Fwe Cart Part No K12.023.14.0.Pr , Cac Adaptorlhs From Fwe Cart Part No K12.023.15.0.Pr , Hose For Cac Pipeid 151 X Id 151 Cart Part No K12.023.61.0.Pr , Joint (For Breather Plate) Cart Part No K12.024.04.0.Pr , O-Ring Dia 3Mm,Id 60 (For Breather Cover Plate) Cart Part No K12.024.06.0.Pr , Breather Hose (Rh Side From Fwe) Cart Part No K12.024.31.0.Pr , Breather Hose Cart Part No K12.024.32.0.Pr , Expansion Bellow Cart Part No K12.025.04.0.Pr , Gasketbetween Head Exhmanifold Cart Part No K12.025.06.0.Pr , Jointbetexhmanifold Expabellow Cart Part No K12.025.09.0.Pr , Jointbetween Turbocharger And Exhmanifold Cart Part No K12.025.11.0.Pr , Adaptor For B3ng Turbocharger (Rhs From Fwe) Cart Part No K12.026.17.0.Pr , Oil Supply Pipe For Tel Turbo Cart Part No K12.026.25.0.Pr , Adaptor For B3ng Turbochargerlhs From Fwe Cart Part No K12.026.36.0.Pr , O Ring B W Adaptor Turbocharger Cart Part No K12.026.38.0.Pr , Joint For Turbo Diffuser Cart Part No K12.026.39.0.Pr , Exhaust Diffuserfor B3ns Turbocharger Cart Part No K12.026.41.0.Pr , Turbocharger B3ns 180 Degfor 1500 Rpm Cart Part No K12.026.49.0.Pr , Turbocharger B3ns 23 Degfor 1500 Rpm Cart Part No K12.026.51.0.Pr , Joint Between T C And Drain Pipe Cart Part No K12.026.59.0.Pr , Oil Drain Pipe For Tel Turbocharger Cart Part No K12.026.64.0.Pr , Flange For Oil Drain Pipedouble O Ring Cart Part No K12.026.65.0.Pr , O Ring For Turbo Drain Pipe Flange Cart Part No K12.026.67.0.Pr , Air Cleaner Elbow Cart Part No K12.026.78.0.Pr , Main Cac Pipe Cart Part No K12.027.06.0.Pr , O-Ring Dia 3Mm, Id 108 Cart Part No K12.027.09.0.Pr , Sleevebetween Adaptor And Cac Pipe Cart Part No K12.027.101.0.Pr , O Ringfor Cac Pipe Sleeve Cart Part No K12.027.102.0.Pr , O Ring Dia 4Mmid 88 Cart Part No K12.027.11.0.Pr , O Ring Dia 4Mmid 125 Cart Part No K12.027.15.0.Pr , O Ring Dia 6Mmid 82 5 Cart Part No K12.027.23.0.Pr , Cac Pipe 2Lhs From Fwe Cart Part No K12.027.91.0.Pr , Cac Pipe 1Lhs From Fwe Cart Part No K12.027.93.0.Pr , Cac Pipe 1Rhs From Fwe Cart Part No K12.027.94.0.Pr , Cac Pipe 3Rhs From Fwe Cart Part No K12.027.97.0.Pr , Oil Seal For Fwesaint Gobain Cart Part No K12.028.14.0.Pr , Barring Assembly Cart Part No K12.028.40.0.Pr , O Ring For Oil Filling Cart Part No K12.031.03.0.Pr , O Ringbetween Sump And Crankcase Cart Part No K12.031.14.0.Pr , O Ring For Centrifuge Cart Part No K12.032.03.0.Pr , O Ring For Oil Flow Sleeve Cart Part No K12.032.05.0.Pr , O Ring For Centrifuge Housing Cart Part No K12.032.08.0.Pr , Single Centrifuge Assy Cart Part No K12.032.20.0.Pr , Rubber Sleevefor Hp Pipe Cart Part No K12.035.04.0.Pr , Upper Clampfor Od 20 Rubber Sleeve Cart Part No K12.036.07.0.Pr , Rubber Sleeveid 15 X Od 20 Cart Part No K12.036.08.0.Pr , Rubber Sleeveid 10 X Od 20 Cart Part No K12.036.09.0.Pr , Rubber Sleeveid 10 X Od 14 Cart Part No K12.036.12.0.Pr , Rubber Sleeveid 6 X Od 14 Cart Part No K12.036.13.0.Pr , Leak Off Pipe Rh Bankfrom Fwe Cart Part No K12.036.130.0.Pr , Lub Oil Supply Pipe Crankcase To Fip Rh Sidef G E Cart Part No K12.036.220.0.Pr , Fuel Pipe Feed Pump To Fuel Filter Lh Bank From Fwe Cart Part No K12.036.250.0.Pr , Fuel Pipe Feed Pump To Fuel Filter Lh Bank From Fwe Cart Part No K12.036.260.0.Pr , Fuel Pipe Feed Pump To Fuel Filter - Rh Bank From Fwe Cart Part No K12.036.270.0.Pr , Fuel Pipe Filter To Fip - Rh Bank From Fwe Cart Part No K12.036.280.0.Pr , Fuel Discharge Pipe Cart Part No K12.036.30.0.Pr , Rubber Sleeve O D 6 X O D 15 Cart Part No K12.036.35.0.Pr , Two Pipe Clamp O D 6 X O D 15 Cart Part No K12.036.36.0.Pr , Injector For K4300 Enginenozzle N16494a 2350 Htf 8 X 146 Cart Part No K12.037.10.0.Pr , Pipe For Bank Connection Cart Part No K12.039.02.0.Pr , Belt For Fandrive Powerband3 Av115x1904 Cart Part No K12.042.08.0.Pr , Belt Forfandrivepower Band 2 Av115x1904 Cart Part No K12.042.09.0.Pr , Governor Dc 12 Master Cart Part No K12.103.01.0.Pr , Magnetic Pick Up 16X1 5 Threading Cart Part No K12.103.02.0.Pr , Starter For K4300rh Cart Part No K12.103.22.0.Pr , Starter For K4300 (Lh) Cart Part No K12.103.23.0.Pr , Governor Dc 12 Slave Cart Part No K12.103.26.0.Pr , Kg 50 2 Rra Assembly 1250 To 1650Kva Cart Part No K12.103.40.0.Pr , Top Cover For Terminal Box K4300 Cart Part No K12.104.02.0.Pr , Differential Ct Assembly For 1250Kvaloose Supply Cart Part No K12.104.40.0.Pr , Copper Busbar Phase R Cart Part No K12.104.42.0.Pr , Copper Busbar Phase Y Cart Part No K12.104.43.0.Pr , Copper Busbar Phase B Cart Part No K12.104.44.0.Pr , Bus Bar Support From Bottom Cart Part No K12.104.46.0.Pr , Bus Bar Support From Top Cart Part No K12.104.47.0.Pr , Copper Busbar Neutral Cart Part No K12.104.48.0.Pr , Differential Ct Assembly For 1500Kvaloose Supply Cart Part No K12.104.50.0.Pr , Adaptor For Oil And Pressure Sensor Cart Part No K12.105.16.0.Pr , Silencer Assemblysilent Set Cart Part No K12.106.19.0.Pr , O-Ring Dia. 4Mm, Id 190 Cart Part No K12.107.07.0.Pr , Vent Pipe From Engine To Radiator Cart Part No K12.107.08.0.Pr , Vent Hose Cart Part No K12.107.09.0.Pr , Cac Pipeengine To Radiator In Cart Part No K12.107.101.0.Pr , Pipe From Thermostat To Radiator In Cart Part No K12.107.102.0.Pr , Cac Pipe Rh Side From F W Eradiator To Engine In Cart Part No K12.107.103.0.Pr , Cac Pipe Lh Side From F W Eradiator To Engine In Cart Part No K12.107.106.0.Pr , Suction Piperadiator To Engine In Cart Part No K12.107.107.0.Pr , Hose For Cac Pipeid 126 X Id 126 Cart Part No K12.107.12.0.Pr , Flexible Vent Pipemale Plug M14x1 5 And M14x1 5 Union Nut Cart Part No K12.107.13.0.Pr , Fair Radiator For K4300 1500 Kva Cart Part No K12.107.78.0.Pr , Hose From Turbo Outlet Cart Part No K12.108.04.0.Pr , Air Cleaner Pipe - 2 (Rh Side From Few) Cart Part No K12.108.29.0.Pr , Anti Vibration Mount -Raem 1500-60 Sh (Trelleborg) Cart Part No K12.110.02.0.Pr , Anti Vibration Mount -Raem 2500-60 Sh (Trelleborg) Cart Part No K12.110.04.0.Pr , Silencer Clamp For K12 Engine Cart Part No K12.114.11.0.Pr , Fuel Pipe From Pre Filter To Feed Pumpm18x1 5 Banjo Both Side Cart Part No K12.116.01.0.Pr , Fuel Inlet Pipe From Pre Filter To Junction Plate Cart Part No K12.116.02.0.Pr , Fuel Inlet Pipe From Pre Filter To Junction Plate Cart Part No K12.116.03.0.Pr , Fuel Return Pipe M22x1 5 Union Both Siderh Side From F W E Cart Part No K12.116.04.0.Pr , Fuel Return Pipe M22x1 5 Union Both Sidelh Side From F W E Cart Part No K12.116.05.0.Pr , Fuel Pipe M22x1 5 Union Both Sidefrom Junction Plate To Tank Cart Part No K12.116.06.0.Pr , Fuel Pipe From Pre Filter To Feed Pumpm18x1 5 Banjo Both Side Cart Part No K12.116.18.0.Pr , Fuel Inlet Pipe From Pre Filter To Tank Cart Part No K12.116.22.0.Pr , Fuel Return Pipem16x1.5 Male Plug Cart Part No K12.116.23.0.Pr , Fuel Return Pipe M14x1 5 Male Plug Cart Part No K12.116.24.0.Pr , Fuel Pipe From Pre Filter To Feed Pump M18x1 5 Banjo Both Siderh Side From F W Cart Part No K12.116.31.0.Pr , Bracket For Fuel Pipe Cart Part No K12.116.41.0.Pr , Control Panel Assembly For K4300 Engine Cart Part No K12.859.20.0.Pr , Star Delta Starter Panel Assembly Cart Part No K12.902.60.0.Pr , Battery Cable 1500Kva Dcc Project Cart Part No K12.903.40.0.Pr , Engine Wiring Harness Sf K4300 Engine Kg745 Unit Cart Part No K12.910.20.0.Pr , Communication Cable Harness For Dc12 Governor Cart Part No K12.910.63.0.Pr , Canopy Wiring Harness Sf K4300 Genset Cart Part No K12.911.30.0.Pr , Ct Wiring Harness From Panel To Alternator For K4300 Genset Cart Part No K12.913.30.0.Pr , K4300 Special Tools Kit Cart Part No K12.999.050.0.Sp , Contactor 25A, 4Pole, 240V Ac Cart Part No Kcl.0006.400.0.00 , Contactor 40A, 4Pole, 240V Ac Cart Part No Kcl.0018.400.0.00 , Contactor 50A, 4Pole, 240V Ac Cart Part No Kcl.0032.400.0.00 , Contactor 63A, 4Pole, 240V Ac Cart Part No Kcl.0040.400.0.00 , Contactor 80A, 4Pole, 240V Ac Cart Part No Kcl.0050.400.0.00 , Contactor 100A, 4Pole, 240V Ac Cart Part No Kcl.0065.400.0.00 , Contcactor 130A , 4 Pole, 240V Ac (Type: Kcl44 85) Cart Part No Kcl.0085.400.0.00 , Conctactor 250A 4 Pole240v Ac Koel Maketypekcl64 150 Cart Part No Kcl.0150.400.0.00 , Conctactor 320A 4 Pole240v Ac Koel Maketypekcl64 225 Cart Part No Kcl.0225.400.0.00 , Conctactor 400A 4 Pole240v Ac Koel Maketypekcl74 330 Cart Part No Kcl.0330.400.0.00 , Conctactor 630A 4 Pole240v Ac Koel Maketypekcl84 500 Cart Part No Kcl.0500.400.0.00 , Conctactor 800A 4 Pole240v Ac Koel Maketypekcl84 800 Cart Part No Kcl.0800.400.0.00 , Camshaft Bush Cart Part No Kl6.011.03.0.00 , Bearing : Main (Std) Cart Part No Kl6.011.12.0.00 , Bearing : Main 075 Cart Part No Kl6.011.15.0.00 , Thrust Washer Cart Part No Kl6.011.17.0.00 , Thrust Washer Cart Part No Kl6.011.18.0.00 , Ring: Seal A16x22 Cart Part No Kl6.011.21.0.00 , Ring Seal Cart Part No Kl6.011.23.0.00 , Ring: Seal A12x18 Cart Part No Kl6.011.25.0.00 , Cylinder Liner Cart Part No Kl6.011.30.0.00 , Nozzle: Oil Spray Cart Part No Kl6.011.31.0.00 , Nozzle: Oil Spray Cart Part No Kl6.011.32.0.00 , Bolt : Hex Cart Part No Kl6.011.33.0.00 , Gasket Cart Part No Kl6.012.02.0.00 , Gasket: Tcg Cover Cart Part No Kl6.012.08.0.00 , Oil Seal Cart Part No Kl6.012.16.0.00 , Gasket Cart Part No Kl6.013.02.0.00 , Oil Seal Cart Part No Kl6.013.08.0.00 , Sensor : Tacho 275/320 Kva Cart Part No Kl6.013.09.0.00 , Gear: Ring Starter Cart Part No Kl6.020.08.0.00 , Con Rod Assly Cart Part No Kl6.020.12.0.00 , Bolt: Collared Hex Cart Part No Kl6.020.14.0.00 , Con Rod Bush Cart Part No Kl6.020.15.0.00 , Con Rod Bearing Cart Part No Kl6.020.17.0.00 , Bearing Con Rod 0 25 Cart Part No Kl6.020.18.0.00 , Bearing Con Rod 0 75 Cart Part No Kl6.020.20.0.00 , Bearing Con Rod 1 00 Cart Part No Kl6.020.21.0.00 , Piston Cart Part No Kl6.020.22.0.00 , Piston Pin Cart Part No Kl6.020.26.0.00 , Snap Ring 45X1.75 Cart Part No Kl6.020.27.0.00 , Bolt Socket Head Cart Part No Kl6.020.30.0.00 , Piston Ring Set - 320 Kva Cart Part No Kl6.020.33.0.00 , Bush: Injection Nozzle Cart Part No Kl6.030.03.0.00 , O Ring Cart Part No Kl6.030.04.0.00 , Valve Seat Cart Part No Kl6.030.09.0.00 , Valve Seat Cart Part No Kl6.030.10.0.00 , Valve Guide Cart Part No Kl6.030.14.0.00 , Cylinder Head Assembly Rear (Modified) Cart Part No Kl6.030.15.0.00 , Gasket: Cylinder Head-Front Cart Part No Kl6.030.23.0.00 , Gasket: Cylinder Head- Rear Cart Part No Kl6.030.24.0.00 , Bolt : Collared Hex. Cart Part No Kl6.030.27.0.00 , Gasket: Cylinder Head Cover Cart Part No Kl6.030.35.0.00 , Bolt : Collared Hex. Cart Part No Kl6.030.36.0.00 , Washer Cart Part No Kl6.030.37.0.00 , Gasket: Cylinder Head Cover Cart Part No Kl6.030.38.0.00 , Housing : Breather Cart Part No Kl6.030.39.0.00 , O-Ring Cart Part No Kl6.030.40.0.00 , Valve: Inlet Altv Cart Part No Kl6.031.01.0.00 , Valve: Exhaust (Altv) Cart Part No Kl6.031.04.0.00 , Spring Valve Spring Asslyex Cart Part No Kl6.031.07.0.00 , Valve Spring (Inner) Cart Part No Kl6.031.08.0.00 , Valve Spring (Outer) Cart Part No Kl6.031.09.0.00 , Retainer : Valve Spring Cart Part No Kl6.031.12.0.00 , Valve Stem Seal Cart Part No Kl6.031.13.0.00 , Cotter : Valve Cart Part No Kl6.031.14.0.00 , Tappet: Valve Cart Part No Kl6.031.31.0.00 , Rod : Push Cart Part No Kl6.031.32.0.00 , Cam Shaft & Gear Assembly Cart Part No Kl6.031.33.0.00 , Oil Pump Assly1020 1260 Cart Part No Kl6.040.01.0.00 , Ball Brg 6006C Cart Part No Kl6.040.22.0.00 , Bolt Socket Head Cart Part No Kl6.040.26.0.00 , Head Oil Filter Cart Part No Kl6.041.03.0.00 , O-Ring Cart Part No Kl6.041.19.0.00 , Element : Oil Cooler Cart Part No Kl6.042.03.0.00 , Gasket: Oil Pipe Cart Part No Kl6.042.04.0.00 , Gasket Cart Part No Kl6.042.09.0.00 , Gasket: Oil Pipe Cart Part No Kl6.042.16.0.00 , Oil Pipe Cart Part No Kl6.042.18.0.00 , Gasket: Oil Pan Cart Part No Kl6.043.02.0.00 , Oil Level Gauge Cart Part No Kl6.043.03.0.00 , Washer Oil Pan Cart Part No Kl6.043.05.0.00 , Pipe Oil Cart Part No Kl6.043.12.0.00 , Gasket: Oil Pipe Cart Part No Kl6.043.13.0.00 , Pipe Oil Cart Part No Kl6.043.17.0.00 , Gasket : Water Pipe Cart Part No Kl6.055.04.0.00 , Gasket: Water Pipe Cart Part No Kl6.055.09.0.00 , Gasket For Cooling Water Pipe (Modified) Cart Part No Kl6.055.10.0.00 , Pipe : Cooling Water Cart Part No Kl6.055.17.0.00 , Hose: Rubber Cart Part No Kl6.055.18.0.00 , Hose Clamp: Nw 28 Cart Part No Kl6.055.19.0.00 , Hose: Rubber Cart Part No Kl6.055.20.0.00 , Pipe Cooling Water Cart Part No Kl6.055.23.0.00 , Gasket: Water Pipe Cart Part No Kl6.055.24.0.00 , Hose Rubber Cart Part No Kl6.055.25.0.00 , Hose Clamp : Nw S40 Cart Part No Kl6.055.26.0.00 , Thermostat Element Cart Part No Kl6.055.33.0.00 , Thermostat Element Cart Part No Kl6.055.34.0.00 , O-Ring Cart Part No Kl6.056.15.0.00 , Manifold Exhaust Cart Part No Kl6.081.02.0.00 , Gasket: Exhaust Mfold Cart Part No Kl6.081.06.0.00 , Bolt : Stud M10 Cart Part No Kl6.081.07.0.00 , Gasket: Intake Mfold Cart Part No Kl6.081.18.0.00 , Gasket: Cold Start Cart Part No Kl6.081.25.0.00 , Gasket Turbocharger Cart Part No Kl6.082.06.0.00 , Joint Elbow Exhaust Manifold Cart Part No Kl6.082.07.0.00 , Hose Cart Part No Kl6.082.36.0.00 , Clamp : Hose Band Type Cart Part No Kl6.082.37.0.00 , V Belt Cart Part No Kl6.083.01.0.00 , Nozzle & Holder Assly Cart Part No Kl6.100.01.0.00 , Gasket: Metal Cart Part No Kl6.100.04.0.00 , Cap: Rubber Cart Part No Kl6.100.05.0.00 , Bolt : Stud Cart Part No Kl6.100.06.0.00 , Pipe Oil Cart Part No Kl6.101.08.0.00 , Oil Pipe Cart Part No Kl6.101.12.0.00 , Fip Coupling Cart Part No Kl6.101.13.0.00 , Gasket Injection Pump Mount Cart Part No Kl6.101.31.0.00 , Hose Cart Part No Kl6.102.01.0.00 , Hose: Rubber Ring Joint Cart Part No Kl6.102.02.0.00 , Fuel Pipe Cart Part No Kl6.102.06.0.00 , Hose Cart Part No Kl6.102.09.0.00 , Clamp : Hose Ring Type Cart Part No Kl6.102.10.0.00 , Spacer Cart Part No Kl6.140.05.0.00 , Bolt : Hex. Cart Part No Kl6.140.06.0.00 , Starter Cart Part No Kl6.140.12.0.00 , Hose, Rubber C/W (Inlet) Cart Part No Kl6.175.02.0.00 , Hose Sil D75 X 80 Cart Part No Kl6.175.11.0.00 , Hose Cooling Water Cart Part No Kl6.175.12.0.00 , Rubber Hose: Thermostat To Radiator Cart Part No Kl6.175.31.0.00 , T-Bolt Hose Clamp 75-68Mm Cart Part No Kl6.175.46.0.00 , Gasket: Water Pump Cover Cart Part No Kl6.176.04.0.00 , Water Pump Assly Cart Part No Kl6.176.05.0.00 , Silencer Cart Part No Kl6.188.10.0.00 , Pipe Cac Cart Part No Kl6.190.01.0.00 , Pipe Cac Cart Part No Kl6.190.02.0.00 , Hose Fuel (Feed Pump To Filter)820Mm Cart Part No Kl6.194.04.0.00 , Hose Fuel (Filter To Fip) 660Mm Cart Part No Kl6.194.05.0.00 , Vent Pipe Radiator To Thermostat M14 X 0.5 Union Both Side Cart Part No Kl6.195.01.0.00 , Clamp Cart Part No Kl6.502.05.0.00 , Fan: 32 Plastic Cart Part No Kl6.515.01.0.00 , Fuel Pipe: 700Mm Long 7/8 Unf Union Both Side Cart Part No Kl6.516.04.0.00 , Fuel Pipe (Length 800 Mm) 7/8 Unf Union (Both Side) For K-Series Silent Set Cart Part No Kl6.528.04.0.00 , Koel Green Alternator Kg250 Stframe Mkg38 M4 Asae 1 14 415V50hz 0 8 Pf Cart Part No Kl6.801.12.0.Pr , Alternator Cart Part No Kl6.802.14.0.00 , Current Transformerset Of 3 Ct Ag3083640060rating400 625 Framekg354 Cart Part No Kl6.911.08.0.00 , Wet Pm Kit (W/O Oil) For Kl6.5001, Kl6.1045 - 6Kl12tasr1 Cart Part No Kl6.999.81.0.Sp , Mccb 75A , 3 Pole, 10Ka Breaking Capacity, Koel Make Cart Part No Kll.0075.310.0.00 , Mccb 75A , 4 Pole, 10Ka Breaking Capacity, Koel Make Cart Part No Kll.0075.410.0.00 , Mccb 100A , 3 Pole, 10Ka Breaking Capacity Cart Part No Kll.0100.310.0.00 , Mccb 100A 4 Pole10ka Breaking Capacity Cart Part No Kll.0100.410.0.00 , Mccb 125A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0125.337.0.00 , Mccb 125A 4 Pole37ka Breaking Capacity Cart Part No Kll.0125.437.0.00 , Mccb 200A , 3 Pole, 26Ka Breaking Capacity Cart Part No Kll.0200.326.0.00 , Mccb 200A , 4 Pole, 26Ka Breaking Capacity Cart Part No Kll.0200.426.0.00 , Mccb 250A , 3 Pole, 26Ka Breaking Capacity Cart Part No Kll.0250.326.0.00 , Mccb 250A , 4 Pole, 26Ka Breaking Capacity Cart Part No Kll.0250.426.0.00 , Mccb 350A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0350.337.0.00 , Mccb 350A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0350.437.0.00 , Mccb 400A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0400.337.0.00 , Mccb 400A 4 Pole37ka Breaking Capacity Cart Part No Kll.0400.437.0.00 , Mccb 500A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0500.437.0.00 , Mccb 630A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0630.337.0.00 , Mccb 630A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0630.437.0.00 , Mccb 800A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0800.337.0.00 , Mccb 800A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0800.437.0.00 , Mccb 1000A 3 Pole50ka Breaking Capacitykoel Maketypekll63 1000With Micro Cart Part No Kll.1000.350.0.00 , Mcb 6A 1 Pole06ka Breaking Capacitycurve Ckoel Maketypekml11 C6 Cart Part No Kml.0006.106.0.00 , Mcb 6A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12 C06) Cart Part No Kml.0006.206.0.00 , Mcb 10A, 1Pole, 06Ka Breaking Capacity, Curve C Cart Part No Kml.0010.106.0.00 , Mcb 16A 1 Pole06ka Breaking Capacitycurve Ctypekml11 C16 Cart Part No Kml.0016.106.0.00 , Mcb 16A , 3 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml13 C16) Cart Part No Kml.0016.306.0.00 , Mcb 25A , 3 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml13 C25) Cart Part No Kml.0025.306.0.00 , Mcb 32A , 1 Pole, 06Ka Breaking Capacity Cart Part No Kml.0032.106.0.00 , Mcb 32A , 3 Pole, 06Ka Breaking Capacity Cart Part No Kml.0032.306.0.00 , Mcb 32A , 4 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml14 C32) Cart Part No Kml.0032.406.0.00 , Mcb 40A 2 Pole06ka Breaking Capacitycurve Ckoel Maketypekml12 C40 Cart Part No Kml.0040.206.0.00 , Mcb 40A3 Pole06ka Breaking Capacitycurve Ckoel Maketypekml13 C40 Cart Part No Kml.0040.306.0.00 , Mcb 40A 4 Pole06ka Breaking Capacitycurve Ckoel Maketype: Kml14 C40 Cart Part No Kml.0040.406.0.00 , Mcb 50A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12c50) Cart Part No Kml.0050.206.0.00 , Mcb 50A, 3Pole, 06Ka Breaking Capacity, Curve C Cart Part No Kml.0050.306.0.00 , Mcb 50A 4 Pole06ka Breaking Capacitycurve Ckoel Maketypekml14 C50 Cart Part No Kml.0050.406.0.00 , Mcb 63A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12 C63) Cart Part No Kml.0063.206.0.00 , Mcb 63A 3 Pole06ka Breaking Capacity Cart Part No Kml.0063.306.0.00 , Mcb 63A 4 Pole06ka Breaking Capacity Cart Part No Kml.0063.406.0.00 , Air Filter Element Cart Part No Kt.1324.64.0.00 , Piston Ring Set -400/500/600 Kva Cart Part No Kv0.001.22.0.00 , Ring: Seal 26X31 Cart Part No Kv0.012.19.0.00 , Seal Ring A14x20 Cart Part No Kv0.012.29.0.00 , Main Bearing Cart Part No Kv0.012.30.0.00 , Thrust Bearing Cart Part No Kv0.012.31.0.00 , Cylinder Liner Cart Part No Kv0.012.33.0.00 , O Ring Upper Cart Part No Kv0.012.34.0.00 , O Ring : Lower Cart Part No Kv0.012.35.0.00 , O Ring Cart Part No Kv0.012.36.0.00 , Nozzle: Oil Spray Cart Part No Kv0.012.43.0.00 , Flange Assly Cart Part No Kv0.012.46.0.00 , Gasket Cart Part No Kv0.012.47.0.00 , Holder Oil Seal Cart Part No Kv0.012.50.0.00 , Oil Seal: Front Cart Part No Kv0.012.51.0.00 , Gasket: Seal Holder Cart Part No Kv0.012.53.0.00 , Main Bearing Cart Part No Kv0.012.56.0.00 , Gasket Cart Part No Kv0.014.16.0.00 , Gasket: Flywheel Housing Cover Cart Part No Kv0.014.22.0.00 , Seal Oilrear Cart Part No Kv0.014.24.0.00 , Sensor : Tacho Cart Part No Kv0.014.25.0.00 , Gasket: Flywheel Housing Cover Cart Part No Kv0.014.29.0.00 , O Ring Cart Part No Kv0.015.02.0.00 , Hose Cart Part No Kv0.015.03.0.00 , Rubber Hose Cart Part No Kv0.015.04.0.00 , Hose Clamp : Nw S20 Cart Part No Kv0.015.05.0.00 , Clamp : Hose Nw 12 Cart Part No Kv0.015.06.0.00 , Ring : Wear, Front Cart Part No Kv0.020.04.0.00 , Gear: Ring Starter Cart Part No Kv0.020.16.0.00 , Bolt : Collared Hex. Cart Part No Kv0.020.18.0.00 , Connecting Rod Assly Cart Part No Kv0.021.01.0.00 , Bolt: Con Rod Cart Part No Kv0.021.04.0.00 , Upper Con Rod Bearing: Std Cart Part No Kv0.021.05.0.00 , Piston Cart Part No Kv0.021.11.0.00 , Piston Pin Cart Part No Kv0.021.12.0.00 , Snap Ring Cart Part No Kv0.021.13.0.00 , Lower Bearing Conrod (Std) Cart Part No Kv0.021.21.0.00 , Lower Bearing Conrod Cart Part No Kv0.021.23.0.00 , Lower Bearing Conrod0 50 Cart Part No Kv0.021.24.0.00 , Con Rod Bush Cart Part No Kv0.021.31.0.00 , Valve Guide Cart Part No Kv0.030.04.0.00 , Seat Intake Valve Cart Part No Kv0.030.05.0.00 , Seat Exhaust Valve Cart Part No Kv0.030.06.0.00 , Cylinder Head Bolt Cart Part No Kv0.030.12.0.00 , Bolt : Cylinder Head Cart Part No Kv0.030.13.0.00 , Gasket: Cylinder Head Cart Part No Kv0.030.14.0.00 , Bolt Assly M8x45 Cart Part No Kv0.030.18.0.00 , Cap : Filler Cart Part No Kv0.030.20.0.00 , Gasket: Cylinder Head Cover Cart Part No Kv0.030.22.0.00 , Valve Guide Finish Cart Part No Kv0.030.23.0.00 , Valve: Inlet Cart Part No Kv0.031.01.0.00 , Valve: Exhaust Cart Part No Kv0.031.02.0.00 , Washer Cart Part No Kv0.031.04.0.00 , Valve Spring Assly Cart Part No Kv0.031.05.0.00 , Valve Spring (Outer) Cart Part No Kv0.031.06.0.00 , Valve Spring (Inner) Cart Part No Kv0.031.07.0.00 , Valve Spring Plate Cart Part No Kv0.031.08.0.00 , Cotter : Valve Cart Part No Kv0.031.09.0.00 , Valve Stem Seal Cart Part No Kv0.031.10.0.00 , Screw : Adjust Cart Part No Kv0.031.13.0.00 , Nut (Hex) Cart Part No Kv0.031.14.0.00 , Push Rod Cart Part No Kv0.031.20.0.00 , Oil Pump Assly Cart Part No Kv0.041.01.0.00 , Washer Spring A8 Cart Part No Kv0.041.03.0.00 , Gasket: Flange Cart Part No Kv0.041.10.0.00 , Lube Oil Filter Cartrige Cart Part No Kv0.043.03.0.00 , Gasket Oil Filter Cart Part No Kv0.043.04.0.00 , Gasket: Oil Cooler Cart Part No Kv0.044.03.0.00 , Washer: Spring A10 Cart Part No Kv0.044.07.0.00 , Bolt : Socket Head Cart Part No Kv0.044.08.0.00 , Oil Cooler Assembly Cart Part No Kv0.044.10.0.00 , Gasket: Flange Cart Part No Kv0.044.12.0.00 , Gasket Cover Housing Cart Part No Kv0.044.17.0.00 , Gasket : Oil Cooler (Old) Cart Part No Kv0.045.10.0.00 , Gasket: Flange Cart Part No Kv0.047.03.0.00 , Ring: Seal A26x32 Cart Part No Kv0.047.14.0.00 , Screw : Hollow Cart Part No Kv0.047.16.0.00 , Hose: Tc Drain Cart Part No Kv0.047.19.0.00 , Gasket: T/C Oil Return Cart Part No Kv0.047.21.0.00 , Gasket: Oil Pan Cart Part No Kv0.049.02.0.00 , Drain: Joint Assly Cart Part No Kv0.049.09.0.00 , Gasket By Pass Filter Cart Part No Kv0.049.14.0.00 , Water Pipe Gasket Cart Part No Kv0.052.03.0.00 , Hose: Sil D75 X 100 Cart Part No Kv0.052.06.0.00 , Clamp: Hose New 64 Cart Part No Kv0.052.07.0.00 , Gasket : Flange Cart Part No Kv0.052.12.0.00 , Thermostat Element Cart Part No Kv0.052.16.0.00 , O Ring: 60X4 Cart Part No Kv0.052.17.0.00 , Gasket: Thermostat Cart Part No Kv0.052.18.0.00 , Water Pump Assly Cart Part No Kv0.052.19.0.00 , Seal : Water Pump Cart Part No Kv0.052.24.0.00 , Gasket: Water Pump Cart Part No Kv0.052.32.0.00 , Pulley V Belt Cart Part No Kv0.052.35.0.00 , Hose Sil D75 X 100 Cart Part No Kv0.052.37.0.00 , Fan : Cooling Cart Part No Kv0.056.12.0.00 , Nut : Hex. M10 Cart Part No Kv0.056.18.0.00 , V Belt: Fan Pulley Ax 52 Cart Part No Kv0.056.28.0.00 , V Belt: Fan Drive 400/500/600 Kva Cart Part No Kv0.056.29.0.00 , V Belt: Water Pump 400/500/600 Kva Cart Part No Kv0.056.30.0.00 , Gasket: Exhaust Mfold Cart Part No Kv0.082.04.0.00 , Washer Cart Part No Kv0.082.06.0.00 , Exhaust Manifold Cart Part No Kv0.082.09.0.00 , Exhaust Manifold Cart Part No Kv0.082.16.0.00 , Ring: Laminated Cart Part No Kv0.082.17.0.00 , Gasket: Exhaust Mfold Cart Part No Kv0.082.18.0.00 , Bolt: Hex Cart Part No Kv0.082.19.0.00 , Spacer : Exhaust Manifold Cart Part No Kv0.082.20.0.00 , Gasket: Intake Mfold 400/500/600 Kva Cart Part No Kv0.085.02.0.00 , Gasket: Intake Mfold 400Kva Cart Part No Kv0.085.04.0.00 , Hose, Tc Inlet Cart Part No Kv0.085.10.0.00 , Rubber Hose Cart Part No Kv0.085.21.0.00 , Hose Clamp Cart Part No Kv0.085.22.0.00 , Gasket: Intercooler Cart Part No Kv0.085.33.0.00 , Turbocharger Assly Cart Part No Kv0.087.02.0.00 , Turbocharger Assly Cart Part No Kv0.087.05.0.00 , Gasket: Turbocharger Cart Part No Kv0.087.08.0.00 , Bolt : Stud Cart Part No Kv0.087.10.0.00 , Nut : Hex. M10 Cart Part No Kv0.087.12.0.00 , Nozzle & Holder Assly Cart Part No Kv0.100.01.0.00 , Nozzle Cart Part No Kv0.100.02.0.00 , Screw: Pressure Cart Part No Kv0.100.03.0.00 , Ring: Seal Cart Part No Kv0.100.04.0.00 , Seal: Nozzle Holder Cart Part No Kv0.100.05.0.00 , Screw : Hollow Cart Part No Kv0.105.06.0.00 , Piece Connection Cart Part No Kv0.105.09.0.00 , Fuel Filter Assly Cart Part No Kv0.105.12.0.00 , O Ring Cart Part No Kv0.105.25.0.00 , O Ring Cart Part No Kv0.105.26.0.00 , Priming Pump Cart Part No Kv0.105.31.0.00 , Fuel Strainer Cart Part No Kv0.105.32.0.00 , Fuel Filter Element Cart Part No Kv0.105.33.0.00 , Controller Actuator Cart Part No Kv0.105.34.0.00 , Hose: Rubber (Feed) Pump To Filter Cart Part No Kv0.108.01.0.00 , Rubber Hose: Filter To Pump Cart Part No Kv0.108.03.0.00 , Gasket Cart Part No Kv0.108.08.0.00 , Union : Banjo, Double Cart Part No Kv0.108.09.0.00 , Valve : Overflow Cart Part No Kv0.108.10.0.00 , Tube Cart Part No Kv0.108.11.0.00 , Ring: Seal A8x14 Cart Part No Kv0.108.12.0.00 , Fuel Pipe Cart Part No Kv0.108.15.0.00 , Screw : Hollow Cart Part No Kv0.108.18.0.00 , Screw : Hollow Cart Part No Kv0.108.19.0.00 , Hose Fuel For 500 And 600 Kva Cart Part No Kv0.108.34.0.00 , Hose Fuel For 500 Kva Cart Part No Kv0.108.35.0.00 , Ring : Seal A10x16 Cart Part No Kv0.109.05.0.00 , Fuel Filter Assly Cart Part No Kv0.110.01.0.00 , Fuelfilter Assembly (Glass Type 500/600 Kva) Cart Part No Kv0.110.02.0.00 , Alternator: Battery Charging Cart Part No Kv0.140.23.0.00 , Pipe : Cooling Water Cart Part No Kv0.175.08.0.00 , Starter Cart Part No Kv0.260.01.0.00 , Air Cleaner Primary Element Cart Part No Kv0.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv0.505.03.0.00 , Strap For Air Cleaner For 10K18tadia 12 Cart Part No Kv0.505.09.0.00 , Air Cleaner Assembly For 10K18ta Engine Cart Part No Kv0.505.10.0.00 , Hose T Bolt Clamp: 130Mm Od Cart Part No Kv0.505.13.0.00 , Hose Bolt Clamp: 137Mm Od Cart Part No Kv0.505.14.0.00 , Gasket : Oil Cooler (New) Cart Part No Kv2.045.10.0.00 , Gasket: Oil Pan Cart Part No Kv2.050.08.0.00 , Clamp : Hose Cart Part No Kv2.086.11.0.00 , Hose Sil D100 X 90 Cart Part No Kv2.086.21.0.00 , Hose: Rubber, Feed Pump To Filter Cart Part No Kv2.108.02.0.00 , Rubber Hose: Filter To Feed Pump Cart Part No Kv2.108.04.0.00 , Radiator Assembly (Supertropical) For 600Kva Cart Part No Kv2.189.01.0.00 , Air Cleaner Primary Element Cart Part No Kv2.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv2.505.03.0.00 , Air Cleaner Cart Part No Kv2.505.10.0.00 , Strap For Air Cleaner For 12K22tadia 14 Cart Part No Kv2.505.12.0.00 , Air Inlet Cap Cart Part No Kv2.505.13.0.00 , Hose T Bolt Clamp: 150Mm Od Cart Part No Kv2.505.14.0.00 , Air Cleaner Cart Part No Kv2.505.20.0.00 , Fuel Pre Filter Assly Cart Part No Kv2.506.20.0.00 , Water Cooled Cac For 12K22ta Heat Doublepass Cart Part No Kv2.508.01.0.00 , Stud For Balance Water Tank 370Mm Length Cart Part No Kv2.508.14.0.00 , Fuel Pipe Inlet Hose: Feed Pump To Pre Filter Cart Part No Kv2.509.01.0.00 , Fuel Pipe Return Hose 2200Mm Cart Part No Kv2.509.02.0.00 , Fuel Pipe- Suction: 12K22ta Cart Part No Kv2.509.03.0.00 , Pre Cleaner Assly Cart Part No Kv2.528.10.0.00 , Auto Vol Regulator : Avr-R450 Cart Part No Kv2.801.13.0.00 , Earthing Cable25 3850 Mm Length50 Sqmm For Altto Panel Cart Part No Kv2.901.04.0.00 , Wet Pm Kit (W/O Oil) For Kv2.5001 - 12K22ta Cart Part No Kv2.999.85.0.Sp , Lub Oil Pump Assembly Cart Part No Kv8.040.01.0.00 , Gasket Oil Pipe Cart Part No Kv8.040.10.0.00 , Oil Pipe Cart Part No Kv8.046.02.0.00 , Gasket Flange Cart Part No Kv8.046.04.0.00 , Gasket : Oil Pan Cart Part No Kv8.048.02.0.00 , Gasket Oil Pan Cart Part No Kv8.048.09.0.00 , Hose: Tc Inlet 400 Cart Part No Kv8.084.07.0.00 , Clamp Hose Cart Part No Kv8.084.15.0.00 , Clamp : Hose, Band Type Cart Part No Kv8.084.22.0.00 , Turbocharger Assly Cart Part No Kv8.087.01.0.00 , Gasket: Turbocharger Cart Part No Kv8.087.07.0.00 , Bolt : Stud Cart Part No Kv8.087.09.0.00 , Rubber Hose: Feed Pump To Filter Cart Part No Kv8.107.04.0.00 , Rubber Hose: Filter To Feed Pump Cart Part No Kv8.107.05.0.00 , Tube Cart Part No Kv8.107.12.0.00 , Fuel Pipe Cart Part No Kv8.107.15.0.00 , Hose: Engine Water Out Connect Pipe Cart Part No Kv8.175.02.0.00 , Pipe Cooling Waterradiator To Engine400kva Cart Part No Kv8.175.03.0.00 , Hose: Engine Water In Connect Pipe Cart Part No Kv8.175.04.0.00 , Hose For Balance Water Pipe Cart Part No Kv8.175.06.0.00 , Rubber Hose Cart Part No Kv8.175.12.0.00 , Air Vent Pipe Cart Part No Kv8.175.14.0.00 , Water Pump Assembly Cart Part No Kv8.182.10.0.00 , Head Oil Filtersingle Suitable For 400Kva Cart Part No Kv8.185.01.0.00 , Anti Vibration Mount Cart Part No Kv8.500.03.0.00 , Anti Vibration Mount Cart Part No Kv8.500.04.0.00 , Air Cleaner Primary Element Cart Part No Kv8.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv8.505.03.0.00 , Air Cleaner Cart Part No Kv8.505.10.0.00 , Hose T Bolt Clamp For Od 92Mm Cart Part No Kv8.505.12.0.00 , Hose T Bolt Clamp: 112Mm Od Cart Part No Kv8.505.13.0.00 , Suction Hose: 8K15ta Engine Cart Part No Kv8.505.25.0.00 , Hose T Bolt Clamp 138 Mm Id Cart Part No Kv8.505.28.0.00 , Fuel Pipe Inlet Hose: 2000Mm L Cart Part No Kv8.507.01.0.00 , Avr Model Tavr-18 Cart Part No Kv8.801.11.0.00 , Roatating Rectifier Assembly With 6 Nos. Diodes Cart Part No Kv8.801.14.0.00 , Varister Cart Part No Kv8.801.33.0.00 , 24 V Dc Relay Board 2Ch. (70 Amp.) 1C/O.Battery -Ve Signal,Din Mounted Cart Part No Kv8.853.05.0.00 , End Clamp Cart Part No Kv8.853.07.0.00 , 4 Pin Connector Cart Part No Kv8.853.14.0.00 , Adaptor1 8Npt X M10x1 5 Cart Part No Kv8.853.22.0.00 , Bush Fwe 010 Kir Tv1 Cart Part No L.019.5.10.013 , Brg.B Cart Part No L.019.5.20.003 , Brg.B Cart Part No L.019.5.20.013 , Main Bearing: 6R1080 Std Cart Part No M.006.4.00.003 , Main Brg: 6R1080 0.25 Cart Part No M.006.4.00.013 , Main Bearing: 6R1080 020 Cart Part No M.006.4.00.023 , Main Bearing 030 Cart Part No M.006.4.00.033 , Main Brg Cart Part No M.020.3.00.003 , Main Bearing: Ra3 T&B G Cart Part No M.038.4.01.003 , Main Bearing: Ra3 T&B G Cart Part No M.038.4.01.013 , Main Bearing: Ra2 T&B G Cart Part No M.038.4.01.023 , Main Bearing 030 Cart Part No M.038.4.01.033 , Main Bearing Cart Part No M.040.4.01.003 , Main Bearing 020 Cart Part No M.040.4.01.023 , Main Bearing: Sl90 Cart Part No M.055.4.00.003 , Main Bearing: Sl90 010 Cart Part No M.055.4.00.013 , Main Bearing 020 Cart Part No M.055.4.00.023 , Bearing Main Kir Sl90 Cart Part No M.055.4.00.033 , Top Two Hole Bearing Main Kir 4R810std Cart Part No M.070.4.00.003 , Main Bearing: Ha394 Cart Part No M.073.4.00.003 , Main Bearing: Ha 394 Cart Part No M.073.4.00.013 , Main Bearing: Ha394 Cart Part No M.073.4.00.023 , Main Bearing: Ha394 Cart Part No M.073.4.00.033 , Main Bearing: Ha494 Cart Part No M.074.4.00.003 , Main Bearing: Ha 494 Cart Part No M.074.4.00.013 , Main Bearing: Ha494 Cart Part No M.074.4.00.023 , Main Bearing: Ha494 Cart Part No M.074.4.00.033 , Main Bearing: Ha694 Cart Part No M.075.4.00.003 , Main Bearing: Ha694 Cart Part No M.075.4.00.013 , Main Bearing: Ha694 020 Cart Part No M.075.4.00.023 , Main Bearing: Ha294 Cart Part No M.093.4.00.003 , Main Bearing 010 Cart Part No M.093.4.00.013 , Main Bearing 020 Cart Part No M.093.4.00.023 , Main Bearing 030 Cart Part No M.093.4.00.033 , Main Bearing: Dv10 Std Cart Part No M.547.4.00.003 , Main Bearing: 4R810 Std Cart Part No M.552.4.00.003 , Main Bearing: 6K1080ta Std Cart Part No M.553.4.00.003 , Main Bearing: 4K1080 Std Cart Part No M.553.4.10.003 , Bearing Main Kir 6K1080eta Crdi, Std Cart Part No M.554.4.00.003 , Valve Collet Cart Part No N11.008.13.0.00 , Bearing 6305 Zz - 62 Mm Cart Part No N11.029.65.0.00 , Flanged Screw - M6 X 1.0 X 10 Cart Part No N11.051.01.0.00 , Flanged Nut M6 X 1.0 Cart Part No N11.051.02.0.00 , Flanged Nut - M8 X 1.25 Cart Part No N11.051.05.0.00 , Flanged Screw - M6 X 1.0 X 12 Mm Cart Part No N11.051.06.0.00 , Humidity Sensor Bolt M10x80 Hex Bolt (Ss) (Hhb1080-Ss) Cart Part No Owc.Mmf.125.02.Sp , Gas Spring Size=12 Capacity=10 Kg (Bgs1210) Cart Part No Owc.Mmf.125.16.Sp , Bacteria Soil For 125 Kg I Land Machine60kg Cart Part No Owc.Mmf.125.26.Sp , Humidity Sensor Plate 100X50x12 (Sp-70) Cart Part No Owc.Mmf.25.05.Sp , Humidity Sensor Bush ?19X18 (Sp-70) Cart Part No Owc.Mmf.25.06.Sp , Humidity Sensor Washer ?19X4.5 (Sp-70) Cart Part No Owc.Mmf.25.07.Sp , Humidity Electronics Box (Ehb001) Cart Part No Owc.Mmf.25.16.Sp , Temperature Sensor Pt 100 Outside Tank 6 Mm Ring Type (Pt100); 3 Mtr (Etso0603100) Cart Part No Owc.Mmf.25.18.Sp , Temperature Sensor Pt 100 Inside Tank 6 Mm X 25 Mm (Pt100)¼ Bsp; 3 Mtr (Etsi0603100) Cart Part No Owc.Mmf.25.19.Sp , Oil Seal 40X52x7 Adl (Rubber Od Double Lip With Garter Spring) (Bos04007) Cart Part No Owc.Mmf.25.21.Sp , Gas Spring Size=9 Capacity=5 Kg (Bgs0905) Cart Part No Owc.Mmf.25.30.Sp , Bacteria Soil For 25 Kg I Land Machine12kg Cart Part No Owc.Mmf.25.44.Sp , Oil Seal 80X100x8 Adl (Rubber Od Double Lip With Garter Spring) (Bos08008) Cart Part No Owc.Mmf.250.06.Sp , Gas Spring 15 Kg (Gs) Cart Part No Owc.Mmf.250.15.Sp , Ceramic Heater 1500 W35 X5 415 Vacech15003505 Cart Part No Owc.Mmf.250.25.Sp , Oil Seal 90X110x10 Adl (Rubber Od Double Lip With Garter Spring) (Bos09010) Cart Part No Owc.Mmf.250.27.Sp , Compost Door Hinge Flat Hinge Dhim 10080Bfh10080 Cart Part No Owc.Mmf.500.03.Sp , Bacteria Soil For 500 Kg I Land Machine350kg Cart Part No Owc.Mmf.500.18.Sp , Gas Spring 10Kg (Bgs1210) Cart Part No Owc.Mmf.75.04.Sp , Blower Motor 300 Cfm, 90 W, 230 Vac (Ebm300090) Cart Part No Owc.Mmf.75.19.Sp , Ceramic Heater 500 Watts, 415 Vac, 24 X 3 (Ech5002403) Cart Part No Owc.Mmf.75.20.Sp , Bacteria Soil For 75 Kg I Land Machine35kg Cart Part No Owc.Mmf.75.23.Sp , Main Motor For Gear Drive, Rating 0.37 Kw, 0.5Hp, 415 Vac, Ki-75 Cart Part No Owc.Mmf.75.45.Sp , Helical Gearbox For Ki-75 Cart Part No Owc.Mmf.75.46.Sp , Bearing 6202 Llu Cart Part No P03.0901.203.0.00 , Bush Bearing Cart Part No P08.0001.012.0.00 , Gasket: Cylinder Head 2Cyl 1.22 Thk Cart Part No P1.007.09.0.00 , High Pressure Pipe Assembly Cart Part No P1.011.10.0.00 , Exhaust Manifold Cart Part No P1.036.01.0.00 , Ball Bearing 6202 Zz Exclusively For Power Tiller Cart Part No P15.0516.011.0.Pr , Gallary Plug Cart Part No P2.001.02.0.00 , Camshaft Assly Cart Part No P2.003.10.0.00 , Lub Oil Pump Assly Cart Part No P2.005.10.0.00 , Valve Seat Insert: Exhaust Cart Part No P2.007.03.9.00 , Exhaust Valve (Chrome Plated) Cart Part No P2.007.06.0.00 , Valve Pair For 3R860 Cart Part No P2.007.40.0.00 , Belt Xpa 1232 Cart Part No P2.015.04.0.00 , Deflector For Oil Seal Cart Part No P2.020.09.0.00 , O Ring Cart Part No P2.021.03.0.00 , Water Pump Assly With Pulley Cart Part No P2.021.10.0.00 , Exhaust Manifold Cart Part No P2.036.01.0.00 , Cover Plate Cart Part No P2.038.17.0.00 , Cap Assembly Cart Part No P2.039.07.0.00 , Gear Casing For 4Wd Cart Part No P2.045.01.0.00 , Drive Shaft Assly. Cart Part No P2.049.20.0.00 , Water Pump Assly Cart Part No P2.051.10.0.00 , Thermostat Housing Cart Part No P2.066.30.0.00 , Joint Cart Part No P2.075.03.0.00 , High Pressure Pipe Assembly Cart Part No P2.093.50.0.00 , Crankcase W/O Bearings Cart Part No P2.100.10.0.00 , Monoblock Crankcaseline Bearing Operation Cart Part No P2.100.40.0.00 , Gear Casing For 3R860 Wr Cart Part No P2.101.01.0.00 , Joint: Gear Casing 3R860 Wr Cart Part No P2.101.02.0.00 , S.S. Joint For Exhaust Manifold Cart Part No P2.106.01.0.00 , Fuel Pipe Feed To Filter Cart Part No P2.114.01.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No P2.114.02.0.00 , Adaptor (For Spin-On Type Filter) Cart Part No P2.118.02.0.00 , Joint: Fuel Pump Gear Cover Cart Part No P2.121.03.0.00 , Crank Shaft Pulley Cart Part No P2.124.01.0.00 , Leak Off Pipe Cart Part No P2.127.10.0.00 , Valve Rocker Assembly Cart Part No P3.010.10.0.00 , Lube Oil Cooler Cart Part No P4.041.01.0.00 , Water Pipe (From Crankcase To Oil Cooler) Cart Part No P4.041.02.0.00 , Water Pipe (From Oil Cooler To Crankcase) Cart Part No P4.041.03.0.00 , Crankshaft Assly.With Cr.Gear Cart Part No P5.005.20.0.00 , Lifting Hook Cart Part No P5.013.02.0.00 , Oil Filling Body Cart Part No P5.014.01.0.00 , Jont For Exhaust Manifold (Non Asbestos) Cart Part No P5.036.02.0.00 , Breather Pipe Cart Part No P5.041.01.0.00 , Tension Adjusting Lever Cart Part No P5.046.01.0.00 , Spacer Bolt Cart Part No P5.046.03.0.00 , Alternetor Mtg Bkt Cart Part No P5.046.04.0.00 , Flywheel Housing (S/F Ace Tractor) Cart Part No P5.075.02.0.00 , Lub. Oil Sump Cart Part No P5.076.01.0.00 , Dipstick Assly Cart Part No P5.078.10.0.00 , Belt Spax 1220 Cart Part No P5.079.01.0.00 , Brg Bush S/E: 6R1080 Eng Se Cart Part No S.006.5.00.703 , Bearing Bush Cart Part No S.034.5.00.703 , Small End Bush Cart Part No S.038.5.01.003 , Bearing Bush S/E: Ra3 Cart Part No S.038.5.01.703 , Bearing Small End Bush Cart Part No S.051.5.00.003 , Bearing Bush S/E: Rbv3 Cart Part No S.051.5.00.703 , Bearing Bush S/E: Rbv4 Cart Part No S.052.5.00.703 , Bearing Bush S/E: Sl90 Cart Part No S.055.5.00.703 , Bearing Bush S E Kir Sl90250kvastd Ub Cart Part No S.055.5.20.703 , Bush Bearing S/E: Ha394 Cart Part No S.073.5.00.003 , Bush Bearing S/E: Ha394 Cart Part No S.073.5.00.703 , Bearing Bush S/E: Ha494 Cart Part No S.074.5.00.003 , Bearing Bush S/E Kir Ha 494 Cart Part No S.074.5.00.703 , Bearing Bush S/E: Ha694 Cart Part No S.075.5.00.003 , Bearing Bush S/E Kir Ha 694 Cart Part No S.075.5.00.703 , Bearing Bush S/E: Ha294 Cart Part No S.093.5.00.003 , Bush Bearing S/E: Ha294 Cart Part No S.093.5.00.703 , Bearing C R Bush Kir Dv10std Ub Cart Part No S.547.5.00.703 , Small End Bush Cart Part No S.547.5.10.703 , Bearing Bush S/E: 4R810 Std Ub Cart Part No S.552.5.00.703 , Bearing Bush S/E: 6K1080ta Std Cart Part No S.553.5.00.703 , Bearing Small End Bush Cart Part No S.553.5.10.703 , Contactor Spare Coil For 25 40 A 240 Vac For Frame 1 Koel Make Cart Part No Scl.0001.240.0.00 , Contactor Spare Coil For 50 63 A 240 Vac For Frame 2 Koel Make Cart Part No Scl.0002.240.0.00 , Contactor Spare Coil For 80 130 A 240 Vac For Frame 3 And 4 Koel Make Cart Part No Scl.0034.240.0.00 , Contactor Spare Coil For 400A 240 Vac For Frame 7 2 Koel Make Cart Part No Scl.0072.240.0.00 , Dowel Dia 18 (Fwe) Cart Part No T1.001.12.0.00 , Bush For Crankcase (Oil Metering) Cart Part No T1.001.16.0.00 , O Ring: Cylinder Liner- Viton Cart Part No T1.002.04.0.00 , Crankshaft Gear Cart Part No T1.003.03.0.00 , Con Rod Bolt Cart Part No T1.004.03.0.00 , Camshaft Gear Cart Part No T1.006.02.0.00 , Thrust Plate Cart Part No T1.006.03.0.00 , Sub Assly Of Camshaft Cart Part No T1.006.10.0.00 , Lub Oil Pump Assembly Cart Part No T1.007.10.0.00 , Bracket: Suction Tube Cart Part No T1.008.03.0.00 , Joint: Suction Tube Cart Part No T1.008.05.0.00 , Delivery Tube Cart Part No T1.009.01.0.00 , Gear Support Cart Part No T1.010.03.0.00 , Retaining Plate Intermediate Gear Cart Part No T1.010.04.0.00 , Assembly Of Intermediate Gear Cart Part No T1.010.10.0.00 , Fuel Pump Gear Cart Part No T1.011.01.0.00 , Hub For Fuel Pump Fear Cart Part No T1.011.03.0.00 , Gear Casing Cart Part No T1.013.01.0.00 , Joint: Gear Cover Cart Part No T1.013.02.0.00 , Valve Guide Finish Cart Part No T1.016.02.0.00 , Valve Guide (Semi-Finish) Cart Part No T1.016.02.9.00 , Cylinder Head Bolt Cart Part No T1.016.07.0.00 , Joint: Water Pump Cart Part No T1.017.02.0.00 , Water Pump Assly Cart Part No T1.017.30.0.00 , Water Pump Assembly-For Crane Cart Part No T1.017.50.0.00 , Starter Ring Cart Part No T1.019.03.0.00 , Push Rod Cart Part No T1.020.01.0.00 , Injector Cart Part No T1.023.28.0.00 , Joint: Rocker Cover Cart Part No T1.024.02.0.00 , Joint: Inlet Mfold Cart Part No T1.025.02.0.00 , Gasket: Exhaust Mfold Cart Part No T1.026.02.0.00 , Spacer (Id 8.5 X Od 13 X 29 L) Cart Part No T1.026.03.0.00 , Copper Coated Allen Bolt- 50.011.08.050 Cart Part No T1.026.04.0.00 , Cover For Fuel Pump Bore Cart Part No T1.035.01.0.00 , Header For Spin On Type Filter Cart Part No T1.036.01.0.00 , Joint: Lube Oil Header Cart Part No T1.036.02.0.00 , Joint For Thermostat Housing Cart Part No T1.037.02.0.00 , Dipstick Assly Cart Part No T1.039.10.0.00 , Dipstick Assembly Cart Part No T1.039.20.0.00 , Joint: Braether Housing Cart Part No T1.040.07.0.00 , Brather Box Assembly Cart Part No T1.040.30.0.00 , Leak Off Pipe Assembly Cart Part No T1.047.30.0.00 , Piston Pin Cart Part No T1.050.02.0.00 , Piston Ring Set Cart Part No T1.050.10.0.00 , Piston Assembly Cart Part No T1.050.20.0.00 , Piston Assembly Cart Part No T1.050.90.0.Sp , Valve Seat Insert: Inlet Cart Part No T1.057.02.9.00 , Valve Seat Insert: Exhaust Cart Part No T1.057.03.9.00 , Valve Pair Cart Part No T1.057.90.0.00 , Cyl Liner Assembly Cart Part No T1.058.10.0.00 , Cylinder Liner Assly Cart Part No T1.058.20.0.00 , Cylinder Liner Assembly With O Ringmls Gasket Cart Part No T1.058.30.0.00 , Cranksahft Assembly Cart Part No T1.074.20.0.00 , Crank Pulley (Eicher) Cart Part No T1.077.01.0.00 , Exhaust Manifold Cart Part No T1.091.01.0.00 , Joint For Adaptor (Hydraulic Pump) Cart Part No T1.098.03.0.00 , Fuel Pipes Fuel Filter To Fip Cart Part No T3.007.01.0.00 , Fuel Pipes Feed Pump To Fuel Filter Cart Part No T3.007.02.0.00 , Cylinder Head Gasket1 22 Mmthick Cart Part No T3.009.03.0.Pr , Sub Asm. Of Cam Shaft Cart Part No T4.003.10.0.00 , Suction Tube Cart Part No T4.004.10.0.00 , Inlet Manifold (Ge Side Top Opening) Cart Part No T4.009.14.0.00 , Inlet Manifold (Cold Side) Cart Part No T4.009.15.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.20.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.220.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.30.0.00 , Rocker Cover Cart Part No T4.015.01.0.00 , Joint: Rocker Cover Cart Part No T4.015.02.0.00 , Joint For Rocker Cover Cart Part No T4.015.05.0.00 , 500 Hrs - B Check Maintenance Kit Cart Part No T4.019.013.0.Sp , Fuel Filter Bracket Cart Part No T4.019.03.0.00 , 1500 Hrs - C Check Maintenance Kit Cart Part No T4.019.15.0.Sp , Air Inlet Manifold, Jcb Cart Part No T4.020.01.0.00 , Driven Hub For Compressor Cart Part No T4.021.02.0.00 , Spider Coupling Cart Part No T4.021.03.0.00 , Driving Hub For Compressor Cart Part No T4.021.04.0.00 , Deep Groove Ball Bearing Cart Part No T4.021.05.0.00 , Gear For Compressor Cart Part No T4.021.06.0.00 , Joint: Compressor Housing To Crankcase Cart Part No T4.021.07.0.00 , Joint: Compressor Cart Part No T4.021.08.0.00 , Cover Plate For Compressor Bore On Crankcase Cart Part No T4.021.09.0.00 , Exhaust Manifold Ge Top Open Cart Part No T4.022.02.0.00 , Bolt Copper Coated 50 002 08 110 Cart Part No T4.022.04.0.00 , Compressor Lub Oil Drain Pipe, Modified Cart Part No T4.024.05.0.00 , Crank Pulley Pcd 1556 Cart Part No T4.027.01.0.00 , Crank Shaft Pulley (137.5 Pcd) Cart Part No T4.027.04.0.00 , Crank Pulley For137 5 Pcdt4 027 09 0 00 Cart Part No T4.027.09.0.00 , Alternator Pulley (Pcd 565 4Pk) Cart Part No T4.027.17.0.00 , Crankshaft Pulley (137.5 Pcd) Cart Part No T4.027.18.0.00 , Crankshaft Puley Pcd135 3 5Pk Poly V Groove Cart Part No T4.027.21.0.Pr , Alternator Tensioning Lever Cart Part No T4.028.01.0.00 , V Belt: Spax 1180 Cogged Cart Part No T4.029.01.0.00 , V Belt: Spax1160 Cogged Cart Part No T4.029.03.0.00 , Cylinder Head Bolt Cart Part No T4.030.05.0.00 , Cyl Head Gaskt With Fire Ring 1.37Mm Cart Part No T4.030.08.0.00 , Gasket: Cylinder Head 1.32 Thk Cart Part No T4.030.09.0.00 , Cylinder Head Assembly Cart Part No T4.030.50.0.00 , Joint: Thermostat Cover Cart Part No T4.031.02.0.00 , Hose (Thermostat Hsg To Water Pump) Cart Part No T4.031.04.0.00 , Thermostat Housing Assmebly M14 Both Sides With Adaptor Cart Part No T4.031.110.0.Pr , Thermostat Housing Assembly Cart Part No T4.031.40.0.00 , Thermostat And Housing Cart Part No T4.031.60.0.00 , Thermostat Housing Assembly (M14 And 0.5 Nptf) Cover Toward Fan Cart Part No T4.031.90.0.00 , Oil Seal Housing Cart Part No T4.033.01.0.00 , Oil Seal Cart Part No T4.033.02.0.00 , Rocker Cover Cast-Iron (Machining) Cart Part No T4.036.01.0.00 , Inlet Adaptor ( On Inlet Manifold) S/F Ecel Cart Part No T4.043.01.0.00 , Breather Hose Cart Part No T4.053.01.0.00 , Hose For Breather (Connecting To Baseplate) Cart Part No T4.053.05.0.00 , Hose For Breather: Connecting To Base Plate Cart Part No T4.053.07.0.00 , Hose For Breather; Connecting To Bend Pipe Cart Part No T4.053.08.0.00 , Leak Off Pipe Assly Cart Part No T4.053.10.0.00 , Hose (Radiator To Pump Inlet Pipe) Cart Part No T4.053.15.0.00 , Hose (For Radiator To Water Inlet Pipe) Cart Part No T4.053.16.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No T4.053.17.0.00 , Hose: Air Cleaner Cart Part No T4.053.18.0.00 , Leak Off Pipe Cart Part No T4.053.21.0.00 , Fuel Pipe Mud Filter To Fip Cart Part No T4.053.24.0.00 , Leak Off Pipe (Injector) (Polyamide) Cart Part No T4.053.38.0.00 , Hose For Radiator To Water Inlet Pipe Cart Part No T4.053.49.0.Pr , Hose Radiator To Pump Inlet Cart Part No T4.053.54.0.00 , Hose In Between Air Cleaner And Turbo Cart Part No T4.053.56.0.Pr , Hose Radiator To Pump Inlet Pipe Cart Part No T4.053.93.0.Pr , Lub Oil Sump Cast-Iron (Rear) Machining Cart Part No T4.054.01.0.00 , Lube Oil Sump Cart Part No T4.054.02.0.00 , Lube Oil Sump Cart Part No T4.054.10.0.00 , Hose For Air Cleaner Cart Part No T4.058.01.0.00 , Lub Oil Pump Assembly Cart Part No T4.067.105.0.Pr , Lube Oil Pump Cart Part No T4.067.55.0.00 , Lub Oil Pump Assly Cart Part No T4.067.75.0.Pr , Lube Oil Pump Cart Part No T4.067.90.0.00 , Oil Supply Pipe Cart Part No T4.070.02.0.00 , Flywheel Assembly Sf Bull India Cart Part No T4.075.10.0.00 , Flywheel And Starter Ring Assembly Cart Part No T4.075.35.0.Pr , Flywheel And Starter Ring Assembly Cart Part No T4.075.70.0.00 , Flywheel Housing Cart Part No T4.076.01.0.00 , Flywheel Housing For Pg Sae3 Cart Part No T4.076.02.0.00 , Flywheel Housing Sae-3 Cart Part No T4.076.06.0.Pr , Engine Mtg. Foot ( Alt Side ) Cart Part No T4.077.01.0.00 , Engine Mtg. Foot ( Starter Side ) Cart Part No T4.077.02.0.00 , Set Of Joints Cart Part No T4.087.10.0.Sp , Set Of O Rings Cart Part No T4.087.20.0.00 , Set Of Copper Washer Cart Part No T4.087.30.0.00 , Engine Mtg Foot (Ge Lh) Cart Part No T4.088.01.0.00 , Engine Mtg Foot (Ge Rh) Cart Part No T4.088.02.0.00 , Crankcase With Bearing Caps Cart Part No T4.090.60.0.Sp , Fan (Pusher Type-Metallic 22 Dia Mtg Hole-55 Pcd) Cart Part No T4.101.43.0.00 , Radiator Cart Part No T4.103.10.0.00 , Cac Core Assembly For T4 103 10 0 00 Aluminium Radiator Assembly Cart Part No T4.103.26.0.Sp , Aluminium Radiator Assembly Cart Part No T4.103.40.0.Pr , Lever For Charging Alternator Cart Part No T4.104.14.0.00 , Engine Wiring Harness For 4Rta Crdi Cpcb4 Cart Part No T4.1043.10.0.Pr , Engine Control Panel To Alternator Avr Harness For Optiprime (57X2 Kva) Cart Part No T4.1043.40.0.Pr , Engine Wiring Harness For 4Rta Crdi Engine B For Optiprime (2X57kva) Cpcb4+ Cart Part No T4.1043.60.0.Pr , Engine Wiring Harness For 4Rta Crdi Engine A For Optiprime (2X57kva) Cpcb4+ Cart Part No T4.1043.70.0.Pr , Canopy Wiring Harness For 4R Cpcb4 Cart Part No T4.1044.10.0.Pr , Canopy Wiring Harness For Optiprime (57X2 Kva) 4R Cpcb4+ Cart Part No T4.1044.20.0.Pr , Control & Power Panel Assembly For 57 Kva 3Ph Cpcb 4 Cart Part No T4.1045.10.0.Pr , Hose For Air Cleaner Cart Part No T4.106.05.0.00 , Hose For Air Cleaner To Inlet Manifold 70 Id 90 Deg Cart Part No T4.106.07.0.Pr , Bracket For Alternator Cart Part No T4.107.01.0.00 , Tensioning Lever For Belt Cart Part No T4.107.02.0.00 , Bracket For Alternator Cart Part No T4.107.03.0.00 , Bracket For Alternator Mounting Cart Part No T4.107.06.0.00 , Bracket For Alternator Mounting Cart Part No T4.107.08.0.00 , Eye Bolt For Alternator Cart Part No T4.107.11.0.00 , Eye Bolt For Alternator Cart Part No T4.107.18.0.Pr , Bracketfor Stretch Belt Arrangement Cart Part No T4.107.19.0.Pr , Bracket For Alternator Cart Part No T4.107.21.0.00 , Bracket For Fuel Filter & A/C Mtg. Cart Part No T4.108.07.0.00 , Engine Mounting Foot Ge (Alt Side) Cart Part No T4.115.01.0.00 , Engine Mounting Foot Ge (Fip Side) Cart Part No T4.115.02.0.00 , Header For Lube Oil Cooler & Filter Cart Part No T4.116.06.0.00 , Joint: Lube Oil Header Cart Part No T4.116.07.0.00 , Header For Lub Oil Cooler & Filter (Finish) (Suitable For 8 Plate Cooler) Cart Part No T4.116.09.0.00 , Joint For Lub Oil Cooler Cart Part No T4.116.12.0.00 , Joint: Air Pipe Tc To Air Inlet Manifold Cart Part No T4.117.03.0.00 , Air Pipe Tc To Air Inlet Manifold Cart Part No T4.117.16.0.00 , Jointfor Cac Pipe Cart Part No T4.117.17.0.00 , Hose (215 Id X 32 Od, 50 Long) Cart Part No T4.118.03.0.00 , Lube Oil Supply Pipe For Turbo Cart Part No T4.118.38.0.00 , Drain Pipe Assembly For Turbocharger Cart Part No T4.118.39.0.00 , Lube Oil Supply Pipe Cart Part No T4.118.40.0.00 , Joint For Turbo Drain Pipe Cart Part No T4.118.41.0.00 , Turbo Lube Oil Supply Piping Assembly Cart Part No T4.118.45.0.00 , Jointbetturbo Adaptor Crankcase Cart Part No T4.118.46.0.Pr , Drain Pipe Assembly Cart Part No T4.118.50.0.00 , Piston Cooling Nozzle Cart Part No T4.119.02.0.00 , Adaptor (M16 To M12) For Turbo Oil Inlet Cart Part No T4.119.11.0.00 , Adaptor (M12 X 175 To M16 X 15)For Turbo Oil Inlet Cart Part No T4.119.12.0.00 , Crank Case With Brgcaps Cart Part No T4.119.30.0.Sp , Gear Cover Cart Part No T4.121.01.0.00 , Joint: Turbo & Exhaust Manifold Cart Part No T4.122.12.0.00 , Joint: Turbo & Diffuser Cart Part No T4.122.13.0.00 , Joint: Turbo & Exhaust Diffuser Cart Part No T4.122.14.0.00 , Joint: Exhaust Manifold & Turbo Cart Part No T4.122.18.0.00 , Exhaust Manifold Cart Part No T4.122.21.0.00 , Exhaust Manifold Cart Part No T4.122.22.0.00 , Exhaust Manifold Cart Part No T4.122.23.0.00 , Socket Head Bolt (M8x50) Cart Part No T4.122.24.0.00 , Stud M8 X 35 Cart Part No T4.122.25.0.00 , Stud (M10x60) Cart Part No T4.122.27.0.00 , Studm12 X 65 Cart Part No T4.122.28.0.00 , Stud (M10 X 70) Cart Part No T4.122.29.0.00 , Stud (M8 X 25) Cart Part No T4.122.31.0.00 , Stud (M10 X 25) Cart Part No T4.122.32.0.00 , Stud (M10 X 30) Cart Part No T4.122.33.0.00 , Socket Head Bolt (M8x22) Cart Part No T4.122.34.0.00 , Stud (M8 X 20) Cart Part No T4.122.35.0.00 , Set Screw (M8x25) Cart Part No T4.122.36.0.00 , Nut - M8x1.25 - Gr.10 Cart Part No T4.122.39.0.00 , Nut - M10x1.5 - Grade 10 Cart Part No T4.122.41.0.00 , Nut M12x1 75 Grade 10 Cart Part No T4.122.42.0.00 , Stud M10x40lfor High Temp Cart Part No T4.122.48.0.00 , Studm10x55 Cart Part No T4.122.49.0.00 , Stud (M8 X 30) 10.9 Grade Cart Part No T4.122.51.0.00 , Set Screwm8x1610 Grade Cart Part No T4.122.52.0.00 , Stud (M10 X 30) Cart Part No T4.122.59.0.00 , Exhaust Manifold With Hr Paint 4R810t Project Bsiiibackhoe Cart Part No T4.122.63.0.Pr , Turbocharger Cart Part No T4.125.03.0.00 , Turbocharger For 4R810 Enginetel No Cart Part No T4.125.07.0.Pr , Gasket Lube Oil Pump & Suction Tube Cart Part No T4.126.07.0.00 , Clamp Strap Rh Suction Tube Cart Part No T4.126.08.0.00 , Clamp Strap Lh (4R810t Suction Tube) Cart Part No T4.126.09.0.00 , Suction Tube Cart Part No T4.126.12.0.Pr , Gasketfor Suction Tube Cart Part No T4.126.14.0.Pr , Suction Tube Cart Part No T4.126.30.0.00 , Camshaft Sub Assly Cart Part No T4.128.20.0.00 , Cam Shaft & Gear Assembly Cart Part No T4.128.40.0.00 , Suction Pipe (Water Pump) Cart Part No T4.130.01.0.00 , Joint: Suction Pipe & Gear Cover Cart Part No T4.130.02.0.00 , Suction Pipe For Water Pump Cart Part No T4.130.03.0.00 , Hose Pipe Cart Part No T4.130.04.0.00 , Joint: Water Pump & Gear Cover Cart Part No T4.131.01.0.00 , Water Pump Pulley-110 Pcd Spa Section Cart Part No T4.131.02.0.00 , Water Pump Assly Cart Part No T4.131.10.0.00 , Fan Spacer70 Mm Cart Part No T4.131.11.0.00 , Water Pump Pulley Spa Section (110 Pcd) (55 Mtg Pcd) Cart Part No T4.131.26.0.Pr , Water Pump Pulley 4Pk Section94 6 Pcd 55 Mtg Pcd Cart Part No T4.131.27.0.Pr , Water Pump Pulley 5Pk Section94 6 Pcd 55 Mtg Pcd Cart Part No T4.131.28.0.Pr , Fan Spacer- 70Mm Cart Part No T4.131.43.0.00 , Water Pump Assemblywith Impeller And Seal Cart Part No T4.131.75.0.Pr , Thermostat & Housing Cart Part No T4.132.50.0.00 , Thermostat & Housing Assembly (M14 Tapping Both Sides) With Core Plug On Lhs Cart Part No T4.132.80.0.00 , 4Pkepdm Poly- V Belt Cart Part No T4.134.05.0.Pr , Delivery Tube Cart Part No T4.136.01.0.00 , Flywheel Assembly Cart Part No T4.138.20.0.00 , Nozzle Leak Off Pipe Assly Cart Part No T4.140.15.0.00 , Nozzle Leak Off Pipe Assly Cart Part No T4.140.25.0.Pr , Rotary Fip: 4R810t 60Hp @ 2400 Rpm Cart Part No T4.143.05.0.00 , Fip: 4R810 Ta 83 Hp@1500Rpm Cpcbii Cart Part No T4.143.07.0.00 , High Pressure Pipe Assembly Cart Part No T4.152.40.0.00 , Assembly Of Intermediate Gear Cart Part No T4.153.10.0.00 , Flywheel Cart Part No T4.155.20.0.00 , Gear (For Hydraulic Pump) Cart Part No T4.158.02.0.00 , Crankshaft Assembly Cart Part No T4.159.30.0.00 , Crankshaft Assembly Cart Part No T4.159.50.0.00 , Con Rod Assly Cart Part No T4.160.30.0.00 , Connecting Rod Assemblyfractured Cart Part No T4.160.40.0.Pr , Fan: 17/5-5/40/Pag/1Zl Cart Part No T4.161.01.0.00 , Spacer 68 Mm Width For Mounting Fan 17/5-5/40?/Pag/1Zl Cart Part No T4.161.03.0.00 , Fan Assembly 17 5 5 40Pag 1Zl Cart Part No T4.161.20.0.00 , Flywheel Housing Sae 3183 Mm Width Cart Part No T4.163.01.0.00 , Adaptor On Flywheel Cart Part No T4.164.02.0.00 , Alternator Bracket Cart Part No T4.165.01.0.00 , Belt Guard Cart Part No T4.166.03.0.00 , Belt Guard Cart Part No T4.166.21.0.00 , Belt Guard For Stretch Belt Cart Part No T4.166.27.0.Pr , Piston Assembly: R810t/Ta Bsiii Cart Part No T4.170.10.0.00 , Piston Ring Set Cart Part No T4.170.20.0.00 , Hose Air Cleaner Bs Iii Cart Part No T4.171.02.0.00 , Bracket For Spinon Filter Mounting Cart Part No T4.174.01.0.00 , Hub With Facial Cam Cart Part No T4.181.03.0.00 , Fuel Pump Gear Cart Part No T4.181.04.0.00 , Cover For Fuel Pump Gear Cart Part No T4.182.01.0.00 , Cover Plate (Aluminium) For Fuel Pump Gear (Finish) (4R810t With Inline Fuel Pump) Cart Part No T4.182.03.0.00 , Gear Casing Cart Part No T4.183.05.0.00 , Fuel Injection Pump For 4R810na Engine Cart Part No T4.185.02.0.00 , Fip: 4R810na49.5Hp @ 2200Rpm Hd Governor Cart Part No T4.185.03.0.00 , Turbocharger For 3R1190ta Cpcb Iv+ Cart Part No T4.187.30.0.Pr , Hose: Air Cleaner Cart Part No T4.191.05.0.00 , Hose For Pvc Pipe Cart Part No T4.191.16.0.00 , Bracket For Air Cleaner Mounting Cart Part No T4.191.19.0.Pr , Fuel Pipe 200 L Cart Part No T4.193.01.0.00 , Exhaust Silencer Assembly For 60 Hp @ 2400 Rpm Bs Iii Engine Cart Part No T4.196.01.0.00 , Exhaust Diffuser Bull Cart Part No T4.197.01.0.00 , Bracket For Exhaust Diffuser Mounting -Bull (Bs Iii) Cart Part No T4.197.02.0.00 , Hose For Aircleaner Cart Part No T4.198.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No T4.201.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No T4.201.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No T4.201.05.0.00 , Fuel Pipe (Feed Pump To Fuel Filter ) Cart Part No T4.201.06.0.00 , Fuel Pipe (Fuel Filter To Pump) (Polyamide) Cart Part No T4.201.16.0.00 , Fuel Pipe(Feed Pump To Fuel Filter ) (Polyamide) Cart Part No T4.201.17.0.00 , Piston Ring Set For 4R810ta Cart Part No T4.202.20.0.Pr , Crankcase Assly Cart Part No T4.203.100.0.00 , Exhaust Diffuser Cart Part No T4.206.11.0.00 , Joint: Turbo & Exhaust Diffuser Cart Part No T4.206.13.0.00 , Bracket For Fuelpipes Cart Part No T4.206.18.0.00 , Joint Cart Part No T4.206.23.0.Pr , Cac Pipe Cart Part No T4.207.07.0.00 , Cac Hose Cart Part No T4.207.08.0.00 , Air Pipe (Turbo To Radiator) Cart Part No T4.207.09.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No T4.207.12.0.00 , Cac Hose Cold Side Cart Part No T4.207.13.0.00 , Cac Pipe Cold Side (Cold Start) Cart Part No T4.207.23.0.00 , Cac Piperadiator To Inlet Manifold Cart Part No T4.207.31.0.Pr , Cac Hot Pipe (Turbo Side) Cart Part No T4.207.32.0.00 , Joint Between Cac Hot Pipes Cart Part No T4.207.33.0.Pr , Cac Hot Pipe (Radiator Side) Cart Part No T4.207.34.0.00 , Hose For Thermostat To Radiator Inlet Cart Part No T4.208.01.0.00 , Hose For Thermostat To Radiator Inlet Cart Part No T4.208.07.0.Pr , Dipstick Assembly Cart Part No T4.209.10.0.00 , Joint (For Adaptor) Cart Part No T4.212.05.0.Pr , Cylinder Head Assembly Cart Part No T4.215.30.0.00 , Piston Assembly For 4R810ta Cart Part No T4.216.20.0.Pr , Piston Assembly For 4R810ta Cart Part No T4.216.30.0.Pr , Flywheel Cart Part No T4.217.10.0.00 , Piston Ring Set Cart Part No T4.218.15.0.Pr , Breather Pipe Metallic Cart Part No T4.222.01.0.00 , Fuel Pipe Pre-Filetr To Feed Pump Cart Part No T4.241.02.0.00 , Fuel Pipe Fuel Tank To Fuel Pump Cart Part No T4.241.05.0.00 , Drain Pipe Cart Part No T4.241.24.0.00 , Starter Cart Part No T4.241.26.0.Pr , Fuel Pipe Kit Cart Part No T4.241.90.0.00 , Air Cleaner Assembly350 Kghr90 Deg Bend Outlet I 0 O 23G080755 Cart Part No T4.246.10.0.Pr , Hose Air Suction Id70xid89 Bend Epdm Cart Part No T4.247.02.0.Pr , Fan Assembly 17 5 5 40Deg Pag 1Zl With Spacer S F Modified Wp Cart Part No T4.326.20.0.Pr , Crankcase With Brgcap Cart Part No T4.400.80.0.Pr , Camshaftsub Assembly Cart Part No T4.401.20.0.Pr , Cylinder Head Assembly With Valve Seat Insert And Valve Guide Cart Part No T4.402.20.0.Pr , H Ppipefor Cyl1 Cart Part No T4.407.30.0.Pr , H Ppipefor Cyl2 Cart Part No T4.407.40.0.Pr , H Ppipefor Cyl3 Cart Part No T4.407.50.0.Pr , H Ppipefor Cyl4 Cart Part No T4.407.60.0.Pr , H Ppipefip To Common Rail 1 Cart Part No T4.407.70.0.Pr , H P Pipefip To Common Rail 2 Cart Part No T4.407.80.0.Pr , Aiternator Pulley Pcd 715 Pk Poly V Groove Cart Part No T4.411.01.0.Pr , Exhaust Pipe (Bellow To Egr Cooler In) Cart Part No T4.416.01.0.Pr , Egr Cooler Cart Part No T4.417.01.0.Pr , Adaptoregr Cooler Water In Cart Part No T4.417.02.0.Pr , Adaptoregr Cooler Water Out Cart Part No T4.417.03.0.Pr , Bracketfor Fuel Filter Cart Part No T4.418.01.0.Pr , Fuel Pipe (Fuel Pump To Fuel Filter)For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.418.02.0.Pr , Hoseegr Valve Water Inlet Cart Part No T4.419.01.0.Pr , Hoseegr Valve Water Out Cart Part No T4.419.02.0.Pr , Adaptoregr Cooler Water In Cart Part No T4.419.04.0.Pr , Egr Pipeegr Cooler Side Cart Part No T4.421.01.0.Pr , Leak Off Pipe Injector For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.424.01.0.Pr , Leak Off Pipe For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.424.02.0.Pr , Leack Off Pipe Cart Part No T4.424.04.0.Pr , Header Cart Part No T4.425.01.0.Pr , Lube Oil Header Cart Part No T4.425.02.0.Pr , Special Banjo Bolt (M12x1.5) Cart Part No T4.430.01.0.Pr , Oil Supply Pipe (Turbocharger) Cart Part No T4.430.10.0.Pr , Rocker Support Assembly (Complete) Cart Part No T4.431.30.0.Pr , Thermostat Housing Assly Cart Part No T4.432.10.0.Pr , Turbocharger For 4R810ta Cpcb4 Pluse 54 4Kw 1500 Rpm Cart Part No T4.433.01.0.Pr , Turbocharger For 4R810t Bsv 49Hp Cart Part No T4.433.03.0.Pr , T4 434 06 0 Pr Cri2 16 Injector Assembly 4R810ta Cpcb4 Plus6x144 X300htf Cart Part No T4.434.06.0.Pr , Ecumd1cs162canopy Mounted For Cpcb 4 Plus Project Cart Part No T4.435.01.0.Pr , Cac Hot Pipe Cart Part No T4.437.21.0.Pr , Cac Cold Pipe Cart Part No T4.437.30.0.Pr , Pk Sec Belt 5Pk 1168 (Epdm) Cart Part No T4.438.01.0.Pr , Strech Fit Belt (5Pk1148) For 4R810 Engine Cart Part No T4.438.02.0.Pr , 5Pk Belt For 4R810 Bsv Cart Part No T4.438.03.0.Pr , Control Panel Schematic For 62 5Kva3ph With Kg640 Ip A Cart Part No T4.466.30.0.Pr , Control Panel Schematic For 62 5Kva 3Ph T4ip B Cart Part No T4.467.40.0.Pr , Bracket For Actuator Ecu Mtg Cart Part No T4.472.01.0.00 , Lever For Ele Actuator Cart Part No T4.472.02.0.00 , Stud Coupler 55 Mm Long Cart Part No T4.472.03.0.00 , Engine Control Unit Cart Part No T4.472.04.0.00 , Bracket For Relay Box Mounting Cart Part No T4.473.01.0.00 , Silencer Assembly Cart Part No T4.486.28.0.Pr , Return Fuel Pipe Cart Part No T4.486.37.0.Pr , Silencer Assembly Cart Part No T4.486.39.0.Pr , Fuel Pipe From Fueltank Unit To Pre Filter In Cart Part No T4.486.91.0.Pr , Air Cleaner Hose To Turbo Cart Part No T4.486.92.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No T4.486.93.0.Pr , Fan Assembly Sucker Type Plastic 17 / 5 - 5 / 40°/Pag/1Zl Cart Part No T4.493.10.0.Pr , Silicon Beading Joint For Fanl Tank Spout Cart Part No T4.502.57.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend I 0 O 57G080789 Cart Part No T4.505.10.0.Pr , Diffuser (Turbo Exhaust To Dop In) Cart Part No T4.522.02.0.Pr , Gasket (For Exhaust Pipe And Doc) Cart Part No T4.522.03.0.Pr , Dpf Egts Subassly 49Hp Cart Part No T4.523.01.0.Pr , V Band Clamp (Docto Mixer) Cart Part No T4.523.04.0.Pr , Gasket(Doc To Mixer ) Cart Part No T4.523.05.0.Pr , Strap For Egt Assembly Cart Part No T4.523.06.0.Pr , 5 66Doc Dpf Assembly 90Outlet Orientation Cart Part No T4.523.10.0.Pr , 5.66Doc+Dpf_Assembly_30°_Downward_Outlet_Orientation Cart Part No T4.523.20.0.Pr , Egt Bracket Assembly Cart Part No T4.523.30.0.Pr , Rocker Cover (Machining) Cart Part No T4.524.01.0.Pr , Ccv Oil In Pipe Cart Part No T4.526.04.0.Pr , Ccv Air Out Pipe Cart Part No T4.526.06.0.Pr , Ccv Drain Pipe Assembly Cart Part No T4.526.15.0.Pr , Turbo Out Hose Cart Part No T4.527.02.0.Pr , Turbo Out Pipe Cart Part No T4.527.03.0.Pr , Gasket Cart Part No T4.527.04.0.Pr , Turbo Supply Cart Part No T4.527.05.0.Pr , Turbo Drain Pipe Cart Part No T4.527.06.0.Pr , Turbo Cross Over Pipe Assy Cart Part No T4.527.10.0.Pr , Oil Supply And Drain Pipe For Turbocharger Cart Part No T4.527.20.0.Pr , Engine Wiring Harness Assembly With Kg934 Unit Cart Part No T4.810.70.0.00 , Engine Wiring Harness Sf 4R810ta Engine Cart Part No T4.820.30.0.00 , 4R810 Flange Heater Wiring Harness Cart Part No T4.821.20.0.Pr , Engine Wiring Harness For 62 5Kva T4 Emerald Cart Part No T4.822.10.0.Pr , Engine Wiring Harness For 62.5Kva Emrald Coldstart Cart Part No T4.822.20.0.00 , Engine Wiring Harness Sf Kg 645 Unit Governor Cart Part No T4.830.20.0.00 , Power Cablepvcfor 62 5Kva 3Ph T4 Emerald Cart Part No T4.910.40.0.Pr , Set Of Joint Cart Part No T4.999.01.0.Sp , Set Of Joint Cart Part No T4.999.03.0.Sp , Connecting Rod Bearing Pair Cart Part No T4.999.05.0.Sp , Set Of Joints Cart Part No T4.999.10.0.Sp , Major Overhauling For Ajax Dumper, Schwing, Backhoe Loader Bull Cart Part No T4.999.11.0.Sp , Top Overhauling For Ajax Dumper, Schwing, Backhoe Loader Bull Cart Part No T4.999.12.0.Sp , Major Overhauling For Jcb Cart Part No T4.999.13.0.Sp , Top Overhauling For Jcb Cart Part No T4.999.14.0.Sp , Major Overhauling For Pg Cart Part No T4.999.15.0.Sp , Top Overhauling For Pg Cart Part No T4.999.16.0.Sp , Wet Pm Kit (W/O Oil) For T4.8941 - 4R810eta Cart Part No T4.999.17.0.Sp , Wet Pm Kit (W/O Oil) For T4.8903, T4.8927 - 4R810ta G1 Cart Part No T4.999.19.0.Sp , Wet Pm Kit (W/O Oil) For T4.8904 Cart Part No T4.999.21.0.Sp , Wet Pm Kit (W/O Oil) For T4.8906, T4.8909, T4.8922, T4.8923, T4.8924 - 4R810ta G1 Cart Part No T4.999.22.0.Sp , Wet Pm Kit (W/O Oil) For T4.8907, T4.8908, T4.8925, T4.8926, T4.8926.Pb - 4R810ta G1 Cart Part No T4.999.23.0.Sp , Electronic Governor Kit: 4R810 Cart Part No T4.999.30.0.00 , Belt Installation Tool Cart Part No T4.999.31.0.Sp , Electronic Governor Kit For 4R810 Cart Part No T4.999.36.0.Sp , Electronic Governor Kit For 4R810 (Emerald) Cart Part No T4.999.37.0.Sp , Bracket Bsv 4R810 Wiring Harness Resting Bracket-1 Cart Part No T4.B049.111.0.Pr , Bracket Bsv 4R810 Wiring Harness Resting Bracket-2 Cart Part No T4.B049.112.0.Pr , Engine Wiring Harness For 49Hp Na Bsv 4R810t Engine Outlet From Flywheel End Cart Part No T4.E049.110.0.Pr , Egt Wiring Harness For 49Hp Bsv 4R810t Engine Outlet From Flywheel End Cart Part No T4.X049.110.0.Pr , Egt Wiring Harness For 49Hp Bsv 4R810t Engine Outlet From Flywheel End For Aja Cart Part No T4.X049.112.0.Pr , Av1 Vr Bush Cart Part No V.001.5.01.003 , Bearing V/R Cart Part No V.038.5.01.703 , Bearing V/R: Ha394 Cart Part No V.073.5.00.703 , Bearing V/R Cart Part No V.074.5.00.003 , Bearing V/R: Ha494 Std Ub Cart Part No V.074.5.00.703 , Bearing V/R Cart Part No V.075.5.00.703 , Bearing T/W 6R1080 (U & L) Cart Part No W.006.3.20.003 , Set Of Bearing T/W: Tv1 Cart Part No W.019.9.00.003 , Bearing T/W: Ra3 Cart Part No W.038.9.00.003 , Thrust Washer: Ig Ra3 Cart Part No W.038.9.10.003 , Bearing T/W: Sl90 Cart Part No W.055.5.00.003 , Bearing Cart Part No W.073.5.00.003 , Bearing T/W Kir Ha 394 Cart Part No W.073.7.00.003 , Thrust Washer Cart Part No W.547.5.00.003 , Thrust Washer Std 4R810 Cart Part No W.552.5.00.003 , 12V, 8Ah Vrla Kirloskar Green Battery Cart Part No Ap1.018.32.0.Pr , 12V Dc, 32Ah, Lead Acid Kirloskar Green Battery Cart Part No Cc1.012.001.0.00 , 12V Dc, 65Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.25.0.00 , 12V Dc, 75Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.24.0.Pr , 12V Dc, 88Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.23.0.00 , 12V Dc, 100Ah, Lead Acid Kirloskar Green Battery Cart Part No 03.793.23.0.00 , 12V Dc, 130Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.731.08.0.00 , 12V Dc, 150Ah, Lead Acid Kirloskar Green Battery Cart Part No 03.793.24.0.00 , 12V Dc, 180Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.731.33.0.00 , Kirloskar Care Genuine Coolant Premix 1 Litre Can Cart Part No 82.020.35.1.01 , Kirloskar Care Genuine Coolant Premix 5 Litre Can Cart Part No 82.020.35.1.05 , Kirloskar Care Genuine Coolant Premix 10 Litre Can Cart Part No 82.020.35.1.10 , Kirloskar Care Genuine Coolant Premix 26 Litres Can Cart Part No 82.020.35.1.26 , Kirloskar Care Genuine Coolant Premix 205 Ltrsbarrel Cart Part No 82.020.35.1.11 , K Clean 1Ltr Can Cart Part No 82.020.35.5.01 , Genuine D.E.F. 10 Litre Can Cart Part No 82.110.20.0.10 , Genuine D.E.F. 20 Litre Can Cart Part No 82.110.20.0.20 , Genuine D.E.F. 210 Litre Barrel Cart Part No 82.110.22.10.00 , Kirloskar Care Super Genuine Oil 1 Liter Can Cart Part No 82.050.10.0.01 , Kirloskar Care Super Genuine Oil 5 Liters Can Cart Part No 82.050.10.0.05 , Kirloskar Care Super Genuine Oil 7.5 Liters Can Cart Part No 82.050.10.0.07 , Kirloskar Care Super Genuine Oil 13 Liters Can Cart Part No 82.050.10.0.13 , Kirloskar Care Super Genuine Oil 20 Liters Can Cart Part No 82.050.10.0.20 , Kirloskar Care Super Genuine Oil 50 Liters Can Cart Part No 82.050.10.0.50 , Kirloskar Care Super Genuine Oil 210 Liters Barrel Cart Part No 82.050.10.2.10 , Kirloskar Care Premium Genuine Oil 1 Liter Can Cart Part No 82.060.10.0.01 , Kirloskar Care Premium Genuine Oil 5 Liters Can Cart Part No 82.060.10.0.05 , Kirloskar Care Premium Genuine Oil 7.5 Liters Can Cart Part No 82.060.10.0.07 , Kirloskar Care Premium Genuine Oil 13 Liters Can Cart Part No 82.060.10.0.13 , Kirloskar Care Premium Genuine Oil 20 Liters Can Cart Part No 82.060.10.0.20 , Kirloskar Care Premium Genuine Oil 50 Liters Can Cart Part No 82.060.10.0.50 , Kirloskar Care Premium Genuine Oil 210 Liters Barrel Cart Part No 82.060.10.2.10 , Kirloskar Care Platinum Genuine Oil 1 Liter Can Cart Part No 82.080.10.0.01 , Kirloskar Care Platinum Genuine Oil 5 Liters Can Cart Part No 82.080.10.0.05 , Kirloskar Care Platinum Genuine Oil 7.5 Liters Can Cart Part No 82.080.10.0.07 , Kirloskar Care Platinum Genuine Oil 13 Liters Can Cart Part No 82.080.10.0.13 , Kirloskar Care Platinum Genuine Oil 20 Liters Can Cart Part No 82.080.10.0.20 , Kirloskar Care Platinum Genuine Oil 50 Liters Can Cart Part No 82.080.10.0.50 , Kirloskar Care Platinum Genuine Oil 210 Liters Barrel Cart Part No 82.080.10.2.10 , Kirloskar Care Gas Genuine Oil 5 Liters Can Cart Part No 82.010.10.0.05 , Kirloskar Care Gas Genuine Oil 20 Liters Can Cart Part No 82.010.10.0.20 , Kirloskar Care Gas Genuine Oil 210 Liters Barrel Cart Part No 82.010.10.2.10 , Kirloskar Care Gold Genuine Oil 50 Liters Can Cart Part No 82.070.10.0.50 , Kirloskar Care - Petro Plus 1.2 Liters Petrol Engine Oil Cart Part No 82.110.30.0.000 , Kirloskar Care Hydraulic Oil_46 Hlp_26 Ltr Cart Part No 82.046.10.0.26 , Kirloskar Care Hydraulic Oil_46 Hlp_210 Ltr Cart Part No 82.046.10.2.10 , Kirloskar Care Hydraulic Oil_68 Hlp_26 Ltr Cart Part No 82.068.10.0.26 , Kirloskar Care Hydraulic Oil_68 Hlp_210 Ltr Cart Part No 82.068.10.2.10 , Kirloskar Care Gear Oil_ 85W-140_5 Ltr Cart Part No 82.065.10.0.05 , Kirloskar Care Gear Oil_85W-140_20 Ltr Cart Part No 82.065.10.0.20 , Kirloskar Care Transmission Oil_Dex Iii_5 Ltr Cart Part No 82.075.10.0.05 , Kirloskar Care Transmission Oil_Dex Iii_17 Ltr Cart Part No 82.075.10.0.17
Contract Date: Dec 30, 2025 Contract Value : 12.53 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
Jammu And Kashmir View Result →
50.
Public Administrative Department #8495645 AOC
Improvement And Development Of Ei And Fans Along With Provision Of Ups System At Lal Kuan Dispensary Under Ward No. 179 Pul Prahaladpur Under Cnz; 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. (a)5/6 amps switch 6 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 3 pin 5/6 A socket outlet 7 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 8 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 100 mm deep 9 Installation of exhaust fan in the existing opening ,including making good the damage ,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep 10 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 11 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole 12 Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(b) 63 amps 13 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) 14 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm 15 Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. 16 Supply of 1200 mm sweep 50 watt, Energy saver ISI Marked BEE 5 star rating AC Ceiling fan suitable for 230 V, Hertz AC supply without regulator with blades, download etc. complete as required. 17 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 18 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not riseabove 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm) , 18-22 WATT 19 SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color 20 Supply, installation testing and commission of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400A to 630 A with heat shrinkable colour coded sleeves suitable for accommodating MCCBs/MCBs/Isolators as incoming and outgoing as required (without MCCBS/MCBS/Isolators) complete with digital meter Module, including voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights including connections etc as required (conforms to IS:8623) 21 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB 22 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A , 36 KA , TPMCCB 23 Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required. 24 SITC of single phase monoblock pump set complete with all accessories workable on 240/415Volts, 50Hz ac supply (a) 1 HP (0.75kw) single phasepump set , head from 12-30 meter suction amd delivery 25x25mm. 25 Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm 26 Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C x 10 sqmm 27 LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separatedriver as per the requirement with Driver efficiency >85%, Input voltage:Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltageprotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as perLM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard complete inall respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C).150 watt 28 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 29 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 30 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 31 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 32 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 33 Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) onthe input grid shall be < 5% at 100 %load. (The required LC filters shall beincluded in UPS cost), extreme power factor kit to be include to limit the inputpf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPSshall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7laging to 0.7 leading power factor loads. UPS shall be suitable for incomingsupply AC single phase 160-270V 50 Hz and delivering output AC supplytrue sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overloadcapacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shallcomply with low voltage electromagnetic compatibility (EMC) achieved asper EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and FrequencyIndependent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPSshould be with IGBT Based Inverter Technology, CommunicationRS232/RS485/SNMP port open protocol for BMS integration as perapproved by Engineering in charge. Required battery racks, DC breaker ofsuitable rating and interconnecting copper conductor cable of suitable sizeand connectors and all required accoseries are inclusive in the cost. TheUPS should have QR code which should contain drawing, test report OEMmanual, Geo- Tag of manufacturing location etc. 6 KVA
Contract Date: Dec 26, 2025 Contract Value : 3.38 Lakh
Local Bodies No of Bidders 3
TenderDetail
Loading tenders