BRR : 10409446
Click Here To View Tendering Authority. Price Bid City/State :  rohini, Delhi
Tender Brief : 1)Annual Repair Maintenance of Various Electrical Installation And Mechanical Equipments Of 119 Type-Iii,Residential Quarters For The Staff Of Gnctd Of Delhi At Sector-11,Rohini,Delhi.(Sh Miscellaneous Ei Work)-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group A 2 Rewiring for light point/ f... Read More
Tender Value
8,70,999
Submission Date
30-09-2025
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 5,50,035.62 L3
2 cnet-technologies Bid Analytics 5,34,009.24 L2
3 cnet-technologies Bid Analytics 5,22,686.26 L1
Work Detail
1)annual repair maintenance of various electrical installation and mechanical equipments of 119 type-iii,residential quarters for the staff of gnctd of delhi at sector-11,rohini,delhi.(sh miscellaneous ei work)-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required. a) group a 2 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. a) group a 3 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm 4 supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. a) 3 x 1.5 sq. mm 5 b) 3 x 4 sq. mm 6 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, painting etc. as required. 7 painting of existing pole & numbering of pole in installed position of height upto 6 mtrs with one or more coats aluminium paint after scapping of old peeled, rusted paint and making even the surface with putty/ filler on complete length of the pole including the cost of hire charges for trolley mounted ladder/tower wagon of suitable height etc. as required at site. 8 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a) in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 9 providing and fixing hard drawn steel wire fabric of size 75 x 25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 10 led batten light (system lumen efficacy ≥105 <120 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd < 10% , p. f.≥0.95, ip20, cri >80, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends, cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin), sdcm(standard deviation color matching) <3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate (t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥105 <120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm) a) 18- 22 watt 11 supplying, installation, testing & commissioning of led recessed/ surface down lighter (round/ square/ rectangular) smd type of following body material with pmma and prismatic diffuser and construction as per is : 10322 with driver as per the requirement with driver efficiency >85%, operating voltage ac 140-270 volt, frequency 50/60 hz, operating temp range -50c to 400c, internal surge protection of 2.5 kv with short & open circuit protection ,thd < 10% , p. f.≥0.95, ip20, cri >80, ugr (unified glare rating) < 19, flicker free (flickershould be below 5%), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000°k /4000°k / 5700°k / 6500°k (as per ansi bin), sdcm (standard deviation colour matching) <3, maximum power consumption should not more than the specified rating and fixture shall be confirming to relevant bis standards. manufactures word mark/ name engraved/ embossing/ screen printing on housing complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥105 and <120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c) powder coated die cast /extruded aluminium body including trim a) 18 watt 12 supplying, installation, testing & commissioning of flood light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd < 10% as per iec 61000-3-2, p. f.≥0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (led, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 5700°k /6500°k (as per ansi bin) , sdcm(standard deviation color matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥105 <120 lm/watt output .lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted.. shape size and cct shall be as approved by engineer-in- charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). a) 100 watt 13 supplying, installation, testing & commissioning of street light led fixture powder coated pressure die cast aluminium body with driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd < 10% as per iec 61000-3-2, p. f.≥0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emiemc as per cispr -15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report,cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin),sdcm (standard deviation colour matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥105 <120 lm/watt output .lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c).a) 72 watt 14 sitc of 200 mm non metalic vantilating fan with louvers/ shutters suitable for 230 v ac supply i/c making hole in the glass or by removing glass and grill to suit the size and packing remaining hole with suitable size 3mm fiber sheet to make good the damage, repair, connection with 3-core 1.5 mm pvc insulated wire etc. as required. 15 supplying and fixing of fancy wall bracket in stainless steel base duly wired with b-22 lamp holder suitable for cfl lamp/led retrofit lamp complete with all accessories i/c connection etc as required but without lamp. 16 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. 17 wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required a) 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 18 supplying, laying and fixing of one number pvc insulated and pvc sheathed / xlpe aluminium conductor armoured power cable of 1.1 kv grade of following size in dwc/hdpe/ rcc/ hume/metal as required. (a) 4 x 25 sq. mmalu. cable. 19 supplying, laying and fixing of one number pvc insulated and pvc sheathed / xlpe aluminium conductor armoured power cable of 1.1 kv grade of following size on wall surface as required.(a) 4 x 25 sq. mmalu. cable. 20 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (od-63 mm & id-51 mm nominal) 21 cutting of r.c.c. / bitumen road etc upto depth of 30 cm work, cutting by machine including making good as same as earlier and disposal of unserviceable material as per direction of engineer - in- charge etc as required complete at site and no payment for other items by department. 22 supplying of following electrical accessoriessuitable for existing different type fitting/switch box etc. as required a) sp 5/6 a, one way modular switch, isi marked 23 b) sp 15/16 a, one way modular switch, isi marked 24 c) 3 pin 5/6 a modular socket outlet, isi marked 25 d) 6 pin 15/16 a modular socket outlet, isi marked 26 e) sp 5/6 a one way switch piano type isi marked 27 f) sp 15/16 a one way switch piano type isi marked 28 g) 3 pin 5/6 a piano socket outlet, isi marked 29 h) 6 pin 15/16 a piano socket outlet, isi marked 30 i) 1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 31 j) 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable 32 k) pvc batten / angle holder 33 l) 63 amps ratings dp mcb 34 m) 1200 mm sweep bee star rating energy efficient isi marked ceiling fan capacitor type with double ball bearing 35 n) 300mm sweep metallic heavy duty 1400 rpm exhaust fans 36 o) 2.5 mf capacitor 37 p) 25a modulare spmcb c curve 38 q) 6a, to 32 a, ratings, sp mcb, c curve, 10 ka breaking capacity 39 r) 6a, to 32 a, ratings, dp mcb, c curve, 10 ka breaking capacity 40 s) 63 a, rating, 2 pole rccb, 30ma 41 t) one module stepped type electronic piano fan regulator 42 u) 3mm thick phenolic laminated sheet 43 v) call bell/ buzzer, single phase
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download f93c6b51-b726-449d-9745-a7fed4b533ff financialevaluation notice
Download boqcomparativechart boq document
Download finance_367849 aoc document
Download finsummary_367849 aoc document
Download File Name File Description
Download d988cf5e-33b2-483b-b30e-e14e9e7dea72 Tender Documents
Download BOQ_367849 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders