View Bid Results For Distribution And Conditioning Tenders

We found 369 Bid Results related to distribution and conditioning tenders. You can find Contractor details who won distribution and conditioning tenders along with contract details in Bid awards announcements section.

Filters
Stage
280
52
37
Tender Publishing Platform
49
320
State / UT
31
93
64
37
25
23
15
14
13
13
12
9
7
7
4
4
4
4
4
3
2
2
1
1
1
1
1
1
1
1
1
1
Contract Value
101
53
142
72
Publish Date
3
1
0
0
0
Sector
28
85
63
60
30
24
18
17
13
9
9
5
5
4
4
3
3
2
2
2
2
2
1
1
1
1
1
1
1
Ownership
5
171
101
57
38
2
Within keyword
Active filters:
Showing 1–8 of 369 tenders matching your filters
2.
Defence #11427184 Technical Bid
Tender for Sch A Part-I To Xi Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Internal Water Supply) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (Sewage Disposal ) , Total Amount Of Sch A Part-Ix (External Water Supply) , Total Amount Of Sch A Part-X (External Electric Supply) , Total Amount Of Sch A Part-Xi (Hot Water Supply) , Schedule A Part-Xii (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , Supply And Fix Engineering Body Desert Cooler Electric Driven Single Phase 230 Volts, Having Nominal Air Flow Capacity Of 4500 Cum Per Hour,Tank Capacity 105 Ltrs,With Auto Louver Movement,With Min Ait Throw 15 Mtr Complete All As Specified And As Directed By Engr-In- Charge. Make:Kenstar Turbocool Neo Hc 105 Or Techno Commercial Equivalent Make. , Supply, Installation, Commissioning Refrigerator, Electric Driven (Single Phase),Capacity 340 Ltrs , Double Door, Smart Inverter Compressor Of Latest Model, Eco Friendly , Digital Display, Toughened Glass Shelves Complete With All Accessories All As Specified And Directed By Engineer In Charge. , Supply Installation, Commissioning Of Metal Top Deep Freezer Double Door Single Phase Storage Type Deep Freezer 320 Ltrs Cap Of Latest Model Complete With All Accessories All As Specified And Directed. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva All As Specified And Directed , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. , Design, Fabricate, Supply, Install, Testing And Commissioning Of Complete Electrical Chimney/Electrical Hood With Filters Comprising Of Following Items. A) Supply,Install,Testing And Commisssioning Of Kitchen Hood Made Ss 304 Matt Finish 1 Mm Thick Wall Mounted Type With Removable Grease Stop And Fixing Brackets,Oil Drain Channel Of Size 36 X 72 Of Required Length Including Drain Collector & Connecting With Exhaust Ducting Etc Complete All As Specified And As Directed-2 Rm B) Supply And Install Removable Grease Stop Filters Suitable Size Complete All As Specified And As Directed- 02 Nos C) Supply,Install,Testing And Commissioning Exhaust Blower Of Capacity 1 Hp ,240 Volts Single Phase 1440 Rpm Connecting With Exhaust Ducting And Suitable Copper Cable Connecting Complete All As Specified And As Directed:-01 Nos D) Supply And Installation Collar Damper Of Suitable Size For Connecting Between Duct And Exhaust Hood Made Out Of 20 Swg Complete All As Specified And As Directed.-02 Nos E) Supply And Fix Anti Vibration Dush With Ms Fabricated Stand Frame Of Suitable Size For Resting Blower Complete All As Specified And As Directed. , Supply And Install Exhaust Ducting Of Size 500 Mm X 500 Mm Made Of Gi Sheet 24 Swg Including Connecting With Ceiling Mounted Exhaust Hood Up To Terrace With Ms Angle Frame 25 X 25 X 3 Mm Thick,Fixing Of Brackets With Nut Bolts,Gaskets Supporting Thread Rod,Channels Etc,Including Painting The Steel Surfaces With Two Coats Of Synthitic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Taps, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S&F Health Faucet (Abs Body) Suitable For 15 Mm Dia Pipe With 1 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified. , S&F Two Way Bib Tap 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. , S&F Wall Mixer For Mixing Hot And Cold Water And Bend For Connecting To Shower,15 Mm Bore Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S & F Flush Cock, Push Type 15Mm Dia, Cast Copper Alloy, Fancy Type, Chromium Plated, For Iron/Cpvc Pipe Or Unions Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Tap With Swan Neck, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down With Long Screwed Shanks And Fly Nuts Screwed For Iron/Cpvc Pipe And Fixed Complete All As Specified And As Directed. , S & F In Replacement Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 10 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb Four Pole 25 Ka, 100 annual periodical maintenance With Fixed Thermal And Magnetic Settings As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar,Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separetely. , S&F In Replacement, Mccb 4 Pole, 415 V, Adjustable Type, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitabl Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Construction Of New Reinforced Cement Concrete Septic Tank For 50 Users Designed To Carry Sewage And Sludge Water, Plain Cement Concrete 1:4:8 Below Foundation, Reinforced Cement Concrete Roof Slab Including Beams, Etc, Using Tmt Crs Bars Grade Fe-500D/Fe-550D, With Vent Shaft , Manhole Opennings With Cover Connection, Including Excavation Earthwork In Any Type Of Soil/ Ordinary Rock Complete All As Shown On Td Drg. Afb/Td/228/2018(S) Sheet 1R/1 Of Ce (Af) Bangalore Zone And As Specified By Engineer-In-Charge. , M&L For Construction Of Soakage Well, Including Excavation In Any Type Of Soil/Ordinary Rock, Foundation In Plain Cement Concrete 1:3:6 Walls Of Honeycomb Masonry With Top Ring Of M-25 Concrete Including Intersepting Chamber Screen Chamber Made Of Fly Ash Brick Masonry In C:M 1:4, Rcc/Dwc Complete Filled With Brick Bats Of Size Of Size 1.80M Dia And 3.0 M Effective Depth All As Shown On Drawing No Cepz/2019/Td/03 Sheet No 1/2 And 2/2 And As Specified By Engineer-In-Charge. , S&F Of Grease Trap Of Capacity 500Lts Having Length X Width X Height Of 1150 X 939 X 765 Mm, To Be Installed Underground Complete All As Specified And As Directed By Engineer-In-Charge. Make : Supreme, Cat No Rlugtp0500gb And Equivalent Series As Approved By Engineer-In-Charge. Note: (A) Excavation, Plain Cement Concrete And Brickwork For Installing Grease Trap To Be Paid Separately Under Respective Items. , Cutting Existing 150 Mm Dia Di Pipe For Inserting Tee Of Size 150X150x50 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
3.
Educational and Research Institute #11403991 AOC
Purchase Of Psychology Equipment , Aesthesiometer (Divider Typ) (Two Point, Graduated Aesthesiometer,All Metal Electro Plated) , Colour Mixer (Also Called Colour Wheel) (Electrically Operated. Variable Speed. Used For Study Of Visual Phenomena Of Colour Perception Of Complementary And Non-Compelmentary Colour Development) , Colour Contrast Apparatus (Different Colour Plates Are Used To Show The Phenomenon Of Colour Contrast. An Indispensable Apparatus To Introduce The Said Phenomenon.) , Successive Contrast Or After Image Apparatus: (The Phenomenon O£ After Image Can Be Studied. The Apparatus Is Handy, Well Furnished And Provides All Materials Required For Studying The Said Phenomenon.) , Depth Perception Apparatus:(The Box With 3 Needles Provides Enough Room For Studying The Depth Perception With Electric Bulb.) , Lifted Weights Set (Metal): (A Set Of 12 Metal Tubes With Removable Or Fixed Tops Containing Certain Weights. Fine Finish And Superior Quality. This Is Required In Weight Discrimination Experiments In Psychophysics For Differential Limen (Dl), Upper Differential Limen U Dl), Lower Differential Limen (Ldl) Determination.) , Muller-Lyer Illusion Figure (With Stand & Scale): (A Study And A Handy Set Of Mullerlyer Illusionfigure. Horizontal Type With A Stand To Adjust The Figure To The Desired Eye Level Of The Subjects. Variable Figure Operated By Smooth Sliding Of The Figure (In Front Of The Experiment) On An Attached Mm Scale. Fine Ficish And Superior Quality Of Work (20‘) , Answer Sheets For Muller- Lyer Illusion (A Pkt.Of 100) , Size-Weight Illusion (Collins-Drever Model) (A Set Of 24 Tubes With Two Standard Stimuli Of Different Weights. Fine Finishing And Superior Quality. Supplied In A Wooden Handy Box.) , Vertical Horizontal Illusion. (T And L Forms With Stand And Scale.) , Optical Illusion Chart:(Cloth Bound Showing Fifteen Well-Know A Illusion, Five Each Of Extent, Direction And Perspective.) , Phi-Phenomenon Apparatus: Electronics.(Consists Of Two Lights Holding Small Cabins With Variable Positions And Time Exposures. Requires Marcury Cup Metronome Also, If An Automatic Operation Of The Apparatus Is Desired.) , Perception-Influence Of Set:(Two Sets Of 12 Cards, Each Of Which Contains A Pair Of Geometrical Figures. One Series Introducing A Set And The Other Serving As An Experimental Series Ideal For Studying Influence Of Set) , Visual Space Perception Apparatus:(Consists Of Well Polished Wooden Box(Size: 30X12X L9J. Having Two Fixed Lights And A Third Movable One With Slides In The Box Perpendicular To The Plane Formed By Tbe Two Fixed Uprights. A Fixed Scale On Top Of The Box Enables One To Find Errors. The Inside Of The Box Is Illuminated By Means Of Two Lamps. Viewing Slit Is Provided On The Smaller End.) , Vase And Face Figures. (In 5X 5 Size On Sturdy, Iraported Card Board. , Galton Bar: (It Is One Of The Early But Still Very Popular Psychophysical Experiments To Demonstrate The Problems Of Subjective (Psychological) Equality. , Whipples Weight Box: (Consists Of 2 Standards And 20 Comparison Weights. The Weights Are Made Out Of Light Metal And Not Of Cardboard As Made By Some Foreign Firms. Supplied With An Attractive Box Lined With Velvet To Hold Weights In Individual Compartments) , Shape And Size Discrimination Apparatus:((T.K.K. Japan Model) This Device Examines The Subjects Size Discrimination Ability Relying Upon Visual And Tactile Sensations As Well As Speed Of Shroting. The Subject Inserts 50 Small Discs Or Coins. Which Are Different In Size And Thickness In Five Different Ways, Into The Corresponding Slit Of Holes As Fast As Possible. The Practice Is Allowed Only Five Times And The Test Is Repeated Twice.) , Colour Preference Cards:(A Set Of 8 Cards Of Different Colours.Can Be Exposed Through The Gravity Tachistoscope) , Colour Preference Wheel: Colour Preference Wheel:(Used For Colour Preference. Using Pair-By-Pair Comparison Method Colour Reference Wheel Is Operated.) , Conflict Board:(With Step Down Transform Mer And A Pad Of 84 Sheets Along With Manual For Demonstrating Experimentally The Reactions To (1) Approach-Avoidance, (2) Approach-Approach, (3) Avoidance Avoidance And (4) Double Approach-Avoidance Situations. A) Manual Available) , Card Sorting Square Tray:(A 4X4 Square Tray Has Been Specially Designed To Eliminate Space Error On Changing The Position Of The Tray. The Pigeon-Hole Numbers Can Be Changed Into Four Different Patterns Simply By Changing The Position Of The Movable Plywood Back Of The Tray, Fine Finish And Superior Quality Work.) , Electric Maze (Human Maze ):(Two Desig Ns On The Same Maze (One For The Experimenter And The Other For The Subject Alternately). Teak Wood, Light Or Sound Signals For Count Ing Errors. Impulse Counter Can Also Be Used. Specially Planned According To The Designs Of The Mazes To Plot The Procedure And Progress Of Learning From Trial To Trial. 420 Points. With Manual. (A)Ebonite Stylus (B)Electrically Operated (C)Electrically With 6 Digits Error Counter (D)Electronics With Digital Timer & Counter. (E)Record Blanks.For Mazes 1 And 2, (A Pkt. Of 100) , Electric Maze Witb Stylus (Human Maze):(Finished With Good Polish, Having 219 Contacts And A Binding Post. Supplied With Stylus.) , Learning By Recognition Method:(A Set Of 35 Cards With Instruction Sheets.) , Slot Maze:(Designed Completely Controlled) , Memory Drum:(Electrically Operated, Four Variable Speed, High-Quality) , Immediate Memory Spantest:((English): (A)Form A (A Pad Of 100)(B)Form B (A Pad Of 100 ) (C)Manual) , Mirror Drawing. (Apparatus: Size 15X 12” X 3/4 Folding Type. Plywood Surface With Hard Plastic Base To Assure Smooth Movement Of The Stylus On Which The Metallic Pattern Is Fixed. For The Electrical Operation, Over All Body Is Made Of Plywood. With Manual: (A)Electrically Operated (B)Electrically With 6 Digits Error Counter (C)E1ectronics With Digital Timer & Counter.) , Mirror Drawing Apparatus: (For Hand Operation, With A Wooden Cover And Star Sheets.) , Short-Term-Memory Test By C.B.Dwivedi (English) ((A)Manual (B)Cards Of Ccc Trigrams (A Pkt. Of 15) (C)Cards Of Meaningful Triads (Pkt.Of 15) , Long-Term Memory Test By C.B. Dwivedi (English):((A)Manual (B)List Of Words For Recognition Test (A Pkt. Of 100) , Pyramid Puzzle:(The Pyramid Problem Involves Placing A Series Of Graduated Blocks On One Of Three Posts Such That A Larger Block Is Never Placed Over A Smaller Block. Useful For Demonstration Of Problem Solving. In Sight Learning And Concept Formation. Average Solution Time With New Subject Is About 20 Min. Repeated Trials With The Same Subject Will Produce Successively Shorter Solution Time.) , T-Puzzle:(For Problem Solving Studies. All Made Up Of Plastic, Superior Quality And Fine Finish) , M-Puzzle (For Problem Solving Studies. All Made Up Of Plastic, Superior Quality And Fine Finish.) , Habit Interference Board With Cards. , Conditioned Reflex Apparatus:(A Thick Glass Plate Is Fixed In A Wooden Frame To Which Is Attached A Felt Hammer. The Hammer When Released Will Fly Up And Strike The Glass In Front Of The Eyes Of Subject. This Is Attached To Head Rest And Can Be Adjusted To Any Height. The Apparatus Is Mounted On A Table By Means Of Clamp Supplied With It. Used For Eyelid Conditioning Experiment.) , Pencil Maze:(A Durable Aluminium Maze With A Hard Surface Bottom To Prevent Grooving. Standard 8.5Al1” Paper Placed Under The Maze Produces A Permanent Record Of Subjects Performance. Can Be Used For A Variety Of Learning Problems.Subjects Are Blind Folded When Tracing The Maze. Speed As Well As Accuracy Can Be Studied Witb The Aid Of A Stop Watch Or Clock Timer.) , Human Problem Solving By C.B. Dwivedi (English):)With Instructions,Designof Experiment And Calculation Procedures. May Also Be Used For Studying The Influence Of Set On Problem-Solving. (A)Booklet : (I) 30 Problem Work Sheets (A Pkt. Of 100) (Ii) 6 Problem Sheets For Studying The Influence Of Set (A Pkt. Of 100) (B)Manual , Water-Jar Problem Solving Test By N.K. Jain:(A Series Of 15 Problems Illustrated Jar Wise. This Is Ideal For Studying Problem Solving In Real-Life Setting. Four Problems Introduce The Situation Followed By Difficult Ones. To Be Used For Studying Effect Of Set On Problem Solving (A)Test Booklet (A Pkt. Of 100) (B)Manuai) , Nonsense Syllables Or Meaningless Word Lists (English)(: From 3 To 11 Syllables. Printed On White Paper And Also In List Form (Set Of 3 Pads) , Paired Associates Word Lists (English): (From 2 To 6 Words. Printed On Separate Sheets (Set Of 4 Pads).) , Massons Disc:(Used To Study The Fluctuations Of Attention.) , Span Of Attention Cards.(A Set Of 12 Cards Having Equal Sized Dots (From 3 To 14) Scattered Randomly. With An Instruction Sheet. Ta)Answer Sheet (A Pkt. Of 100) , Doc Figures (Same Dot Figures Are Used In Studying The Phenomenon Of Attention) , Tachistoscope(Jaiota-Gravity Type):( Tachistoscope With Three Different Adjustable Windows. The Tachistoscope When Unfolded Provides An Automatic Screen Between The E And S. All Leak Wood, Fine Gray Paint Or Polish. With Manual) , Tachistoscope(Fall Type):(Can Be Used For The Study Of Span Of Apprehension And Memory. All Teak Plywood Made, Fine Polish Or Gray Paint. Smooth And Comparatively Noiseless Operation Attempted.) , Judging Emotions From Photographs:(A Set Of 12 Photographs.) , Division Of Attention Board Apparatus:(Electrically Operated With Error Counter.) , Colour Preference Cards:(A Set Of 8 Cards Of Different Colours. Can Be Exposed Through Gravity Tachistoscope) , Colour Preference Wheel :(Used For Colour Preference. Using Pair By Pair Comparison Method Colour Preference Wheel Is Operated.) , Vernier Type Chronoscope:(Specially Made Of Heavy Bottom (All Metal) To Prevent Any Accidental Movements.) , R.T. Apparatus:(Giving Choice R.T. Using Two Light Stimuli) , Mental Fatigue Test By N.K. Jain (English):(With Instruction Sheet. (A) Numerical Sheets (A Pad Of 100) (B) Alphabetical Sheets (A Pad Of 100) (C) Instruction Sheet) , Work And Rest Test By M.C. Joshi (English):(A)Alphabetical Sbeets : Form A For Work (A Pkt. Of 100) (C)Numerical Sheets : Form A For Work (A Pkt. Of 100) (C)Manual , Normal Curve Demonstration Apparatus (Laffayate Model)(This Is An Effective Visual Demonstration Device For Showing The Natural Normal Distribution Curve And Illustrating A Graphic Picture Of The Law Of Probability. Marbles Should Be Inserted Through The Hopper To A Preset But Adjustable Position To Produce The Normal Distribution Curve. This Unit Is Ideal Both For Demonstration In Statistics Classes As Well As For Those Experiments Requiriag Assessments Of Normal Probability Phenomena By The Subject. Instruction Manual Is Also Available.) , Teaching Aptitude Scale By Sanjay’ Vohra (English):(This Test Has Ll9 Items. It Measures Aptitude In Eight Areas: Communication, Intelligence,Maturity, Perceptiveness, Persistence, Receptiveness, Social Warmth And Teaching Interest. This Test Is For Teachers And Takes 40 Min To Complete. A) Reusable Booklets (Pkt. Of 25) B) Answer Sheets (Pkt. Of 100)C) Profile Sheets (Pkt. Of 100) D)Scoring Key E) Manual , Duncans Sales Aptitude Test (Indian Adaptation) By Sanjay Vohra (English):(This Test Has Been Designed To Help In Appraising Sales Ability, Potential In Selecting Sales Personel. If Provides An Objective Measure Of One Important Aspect Of Sales Aptitude, Namely Knowledge And Understanding Of Basic Principles Of Selling. This Test Is For 18 Years And Above. 20 Min To Complete. A) Test Booklets (Pfit. Of 25) B) Answer Sheet (Pkt. Of 100) C) Scoring Key D) Manual) , Machanical Aptitude Tests Battery (Matb) By Atmananda Sharma (Hindi/English):(Time 25 Min. Age 13 To 17 Years, Class Viii Io Xii. Test-L: Mechanical Knowledge Measures ‘Knowledge Of Tools Of Children. Non-Verbal And Culture Free. Directions And Examples.Test-Ii: Mechanical Comprehension Measure Factor ‘M’ Of Children. Non-Verbal And Culture Free. Test-Ill: Space Relations- Measures Factors ‘S’ Spatial Visualisation Of Children. Non Verbal And Culture-Free. Test-Iv: Form Relations-Measures Factor ‘P, Perceptual Ability And Inductive Reasoning Of Children. Test-V: Mechanical Adaptability-Measures Background In The Field Of Science, Scientific Applications And Related Activities Of Children) , Multi Factor Interest Questionnaire By Kapoor & Singh (English )(It Provide Scores On Eight Factors- Business, Clerical, Agricultural, Mechanical, Scientific, Outdoor Activities, Aesthesties And Social Meant For 11 To 18 Years.) , Vocational Interest Record By S.P. Kulshrestha (English)(The Present Record Contains 200 Vocations Belonging To Ten Different Vocational Interest Areas - 1. Literary, 2. Scientific, 3. Executive, 4. Commercial, S. Constructive, 6. Artistic, 7. Agriculture, 8.Persuasive, 9. Social, 10. Household. This Test Is Suitable For Delta And Higher Secondary Students, As Well As For The Students Of Colleges And Also For Soung Adults Out Of Schools And Colleges. (A}Test Booklets (A Pit. Of 100) (B)Manual , Educational Interestrecord By S.P. Kulshrestha (English):(The Present Record Contains 98 Edcational Subject/Activities Belonging To Seven Different Education Al Interest Areas. They Are -1. Agriculture, 2. Commerce, 3. Fine Arts, 4. Home Science, S. Humanities,6. Science, 7. Technology.(A)Test Booklets (A Pkt. Of 100) (B)Manuai , Student Teacher Value Inventory By Meenakshi Biswal (English)((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Adjustment Inventory By Nilima Deka (English):((A)Test Booklets (A Pkt. Of 100} Manual) , Bells Adjustment Inventory By Huge M. Bell (English):((A)Tesl Booklets (A Pkl. Of 100) (B)Manual (C}Scoring Key) , Marital Adjustment Questionnaire By P. Kumar & Kanchana Rohtagi (English):(This Is Having 27 Items In Yes Or No Type Scale, And Reliability And Validity Indices Have Been Worked Out. Percentile Norms Are Given. Age Ranging From 28 To 45 Years. (Test Booklets (A Pkt. Of 100) (B)Manual) , Test Of Democratic Values By Alok Gardia (English):(A Reliable & Valid Test Of Democratic Values Which Contains 40 Multiple Choice Items. The Test Measures Six Democratic Values Namely Dignity Of Individual, Liberty, Equality’, Justice. Cooperation & Tolerance. It Can Be Administered On Upper Primary To Higher Secondary Students.The Test Is Also Suitable For Prospective Teachers (B.Ed. Students) And Teachers Of Different Schools. It Can Also Be Administered On Students Of Higher Education. (A)Test Booklets (A Pkt. Of 100) (B Manual) , Personal Adjustment Inventory For Creative Children By C.B. Asaha English):((A)Test Booklets (A Pkt. Of 100) (B)Manual) , A Test For Measuring Decision Making Capacity Of Educational Administrators By A.K.Pandey (English): ((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Prosocial Behaviour Scale By Mahejabin& P.C. Shukla: (New)(This Tool Based On Likert Scale. The Scale Comprises 36 Items, On The Basis Of Six Dimensions. It Can Be Administered On The Secondary And Higher Secondary School Students. Split-Half Reliability Of The Testis 0.77 And Cronbach Alpha Is 0.794. This Test Measures The Level Of Prosociality, Which Indicates High Academic Achievement, Well Adjustment, Healthy Teacher-Taught Relationship And Social Harmony. Therefore, This Test Is Very Helpful To Develop Healthy Adjustment Skill, To Develop Healthy Reiationsbips& Social Harmony. This Tool Can Also Be Used As An Indicator Of Academic Achievement & Healthy Personality.A) Test Booklets (A Pkt. Of 100) B) Manual , Verbal Test Of Intelligence By M. Asthana And K.B. Verma (English):(This Test Covers Eight Areas Of General Mental Ability, Viz, Best Answer, Reasoning, Similar, Opposite, Analogy’, Mathematical Series, Mathematical Instruction And Classification.Norms Have Been Prepared Age-Wise. Age 13 To 21 Years. Time 20 Min No. Of Item100. (A)Resuable Test Booklets (A Pkt. Of 20) (B)Answer Sheets (A Pkt. Of 100) (C)Manual (D)Scoring Key(Stenciltype) , Group Test Of General Mental Ability By S. Jalota (English):(It Is A Point Scale Of General Ability For College-Educated Adults. (A)Resuable Test Booklets (A Pkt. Of 20) (B)Answer Sheet (A Pftt. Of 100)(C)Manual (D)Scoring Key) , The Southend Test Of Intelligence (English)((A)Test Booklets (A Pkt. Of 100) (B)Manual (C)Practice Sheets (A Pkt. Of 100) , On-Verbal Intelligence Test By Atmanand Sharma:(It Measures ‘G’ Of Children Age 11 To 16 Years, Grades Vi To X. Ii Is Culture-Free. Working Time 25 Min. (A)Tesl Booklets (A Pkt. Of 10) , Emotional Intelligence Test (For Adolescents) By Meena Jain & Madhu Jain:((A)Booklets (A Pkt. Of 100) (B)Manual) , Emotional Intelligence Test By Rakesh Pandey(Age Group 18 To 35 Years. The Scale Is Based On The Most Widely Used And Scientifically Validated Ability Model Of Emotional Intelligence Proposed By Mayer And Salovey. It Is A 51-Items Self Report Measure That Provides A Quick Assessment Of The Your Dimensions Of Emotional Intelligence, (A) Perception, Appraisal And Expression Of Emotion, (B) Emotional Facilitation Of Thinking, (C) Understanding And Analyzing Emotions, Employing Emotional Knowledge, (D) Reflective Regulation Of Emotion To Prompt Emotional And Intellectual Growth. The Scale Has Been Validated On A Wide Range Of Population And May Be Administered To Any Age Group Capable Of Comprehending Verbal Expressions. The Authors Have Tried This Scale On Adolescents And Adults Also And Found It Reliable And Valid. The Scale Can Be Used In Clinical Setting As Well As In The Area Of Health Psychology, Educational Psychology’ And Other Areas Of Psychological Investigations That Focus On The Role Of The Ability To Understand, Manage And Utilize Emotions For Personal Growth And Well Being. (A)Test Booklets (A Pkt. Of 100) (Bjmanual) , Emotional Intelligence Scale By Udham Singh &K.Ozha (English): (Age Group 15 To 30 Years. No. Of Item 46. Dimension Measure In This Test Are - Knowing And Managing Our Emotions, Motivatiting Our Self, Knowing Others Emotions, Handling Relationship With Others.A)Test Booklets Qa Pkt. Of 100) (B)Manual) , Social Intelligence Test By S.Mathur (English):(No. Of Item 50. Age Range 14 To 50 Years. A) Test Booklets (A Pkt. Of 100) B) Manual C)Scoring Key) , Culture Fair (Free) Intelligence Scale Indian Print By Kapoor, Rao & Singh/Cattell And Cattell (Indian Adaptation):(Minimise Cultural Bias. These May Be Administered Individually Or In A Group. They May Be Used To Identify Learning Problems Of Individuals And Assess Applicants Potential To Perform Job Relevant Tasks. (A)Scale I (English) (Cfis-I): For 4 To 8 Years And Older Retardates. Time - 25 Min. Norms Mental Age And L.Q. (B)Scaie Ii(English/Hindi) (Cfis-Ii E): For 8 To 14 Years And Average L.Q. Adults. Lt Contains Four Sub Tests Involving Different Perceptual Tasks.Completing Series,Classifying, Solving Matries And Evalua Ting Conditions.Time Taken 15 Min. (C) Scale Iii (English/Hindi) (Cfis-Iii E): For 14 Years And Above, I.E., Senior Secondary, College And High I.Q. Adults. By Employing Four Distinct Tasks, The Composite Intelligence Measure Avoids Reliance On A Single Skill. The Scale Is Recommended When Testing Better Educated Or More Intelligent Individuals, Because Of The Higher Difficulties Level Of Items And A Greater Refinement In The Higher Intelligence Ranges.) , Bhatia Battery Performance Test Of Lntelligence By C.M. Bhatia(Age Ii To 16 Years.) , Alexanders Pass Along Test:(Age L0+ Years Complete Set With Duco Painted Material And Design Cards Contained In A Wooden Or Plastic Box With Record Sheets (Pads Of 50) And Manual.) , Indian Adpatation Of Binet-Simon Scale((1960) By S.P. Kulshrestha) , Cube Construction Test:(Complete Set Witb Duco Painted Material And Models In Wooden Or Plastic Box Witb Record Sheets (Pad Of 50 Each With Manual) , Kohs Block Design Test:(Age 10* Years. Complete Set With Duco Painted Material And 17 Design Cards In Plastic Box With Record Sheets (Pads Of 50 Each) And Manual) , Manikin Test:(Six Pieces Representing Six Major Parts Of The Human Body To Be Fitted Together To Make A Conventionalized Figure Of A Man.) , Dearborn Form Board With Manual:(Contains The Form Board With 12 Designs Of Different Types. Two Wooden Blocks Used As Stimuli Are To Be Placed In Them. Measures Efficiency Skill.) , Pintner-Patterson Five Figures By Rudulf Pintner And Patterson:(With Manual. Contains Eleven Wooden Blocks And Five Figures. The Blocks Are To Be Fitted In Figures. May Be Used To Measure Quick Performance And Learning.) , Pintner-Patterson Short Scale Of Performance Test:(By Rudolf Pintner & Patterson: This Scale Comprises 10 Sub-Tests And Is Useful For Retesting Or Such Other Purposes. Complete With Materials For All 10 Sub-Tests.) , Hanfmann-Kasanin Concept Formation Test:(Consists Of 22 Properly Coloured Wooden Blocks. The Blocks Consist Of 5 Different Colours, 2 Different Heights And Sizes And Six Different Shades. Supplied Witb A Box.) , Reasoning Ability Test (Rat—D)(By L.N. Dube}’ (Englisb): This Test Consists 60 Items. For 12 To 17 Years Students Of Either Sex.) , Rais Concept Formation Test By G.C. Rai (College/Adult Form):(By L.N. Dube}’ (Englisb): This Test Consists 60 Items. For 12 To 17 Years Students Of Either Sex.) , Scientific Thinking Style Questionnaire By P.N. Singh & Ranjana Arora (Hindi/English}(No. Of Item 30. In The Preparation Of The Present Scale All The Six Components, Viz., Amoral, Creative, Developmental, Parsimonious, Testable And Unified Of The Nature Of Scientific Knowledge Have Been Used. Data Collection On The Graduate 1Evel.) , Interview Schedule For Measuring Achievement Oriented Child Rearing Practice By Manju Mehta (English)(: Four Items Related To Each Of The Following Orientation Were Prepared. Activistic-Passivistic-Orientation, Present-Future Orientation, Individualistic-Feministic Orientation. Various Achievement And Independence-Related Demands Were Found To Be Made At Different Age Levels Varying From 2 Years To 15 Years. The Question Used In Second Try Out In The Final Schedule, For Knowing Mothers Standard Of Age For Achievement And Independence Demands. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Pat Anxiety Scale (As- Ck5) By R.B. Cattbbbell, S.K.Krug&I.H.Scheier (English, Indian Print):(This 40 Item Questionnaire Provides A Convenient And Practical Measure Of Anxiety Level. It Is Constituted On The Basis Of 5 Principal 16 P.F. Factors Namely Emotional Instability, Suspiciousness, Guilt Proneness, Low Integration And Tension. It Is Meant For 16 Years And Adults. Approximate Time 15 Min. Standard Scores For Adult, College And High School Population.) , Guidance Need Inventory (Gni) By Sudha Kumari Sharma & Shahwar Fatima Zaidi (English) (No. Of Items 92. Dimensions-Educational, Vocational, Personal, Social, Emotional. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Mental Health Checklist By Pramod Kumar (Hindi/English):(This Check List Consists Of 11 Items. It Measures Mental Health Of Adult Age Range 18-28 Years. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Mental Depression Scale By L.N. Dubey (English):(No. Of Items Are 50. The Age Range 12 To 55 Years. (A)Tesl Booklets (A Pkt. Of 100) (B)Manual (E)Scoring Key) , Suicidal Behaviour Questionnaire By Sheweta Shandilya & Alok Gardia( English):(This Test Measures Four Areas Taps Into Lifetime Suicide Ideation And Or Suicide Attempt, The Frequency Of Suicidal Ideation Over The Past 12 Months, Taps Into The Threat Of Suicidal Attempt, Evaluatesself- Reported Likelihood Of Suicidal Behaviour In The Future. Age Group School And College Students. (A) Test Booklet (A Pit. Of 100)B Manual) , Case Study Test By L.N. Dubey (Hindi/English):((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Medico Psychological Questionnaire By J. Bharat Raj (English)(This Questionnaire Consists Of 50 Items. It Measures Hysteria, Neurasthenia, Anxiety Neurosis, Reaction De Pression, And Obsessive- Compulsivetendency Of Normal And Abnormal Person. It Measures Neurotieism In Terms Of Emotional Adjustment And Emotional Maladjustment. It Is Standardized On College Student Of Both The Sex.) , Introversion-Extraversion Test By M.C. Joshi English):((A)Test Booklets (A Pkt. O£ 100) (B)Instruction And Score Cards (1Pair) , Kundu Introversion- Extroversion Test By R.N. Kundu (English):(A) Test Booklets (A Pkt. Of 100) B)Manual , Personal Efficacy Scale By A.P. Sing & Patiraj Kumari (1991, Hindi/English):(No. Of Items Are 19 For Adult. Norms And Relibaility Are Not Available) , Sex Differentiation Scale By A.P. Singh & Patiraj Kumari (1991, English):(No. Of Items Are 19 For Adult. Norms And Relibaility Are Not Available) , Family I Nvolveoient Inventory By A.P. Singh & Pramila Tiwari (2003, English): (No.Of Items Are 24. Norms Are Not Avalible. For Adults.) , Life Satisfaction Scale Bv A.P. Singh & Pramila Tiwari(2003,Engiish):(No Of Items Are12.Foradults.) , 16 P.F. Test S.D. Kapoor (Hindi/English): Indian Adaplation:(It Has 16 Primary Scales And Other Numerous Derivative Scales. A Test Of Normal Adult Personality The 16 P. F, Form A To E Effectively Measure Levels Of (I) Warmth, (Ii) Intelligence, (Iii) Emotional Maturity, (Iv) Dominance, (V) Impulsivity, (*I) Super Ego Strength, (Vii) Boldness, (Viii) Sensitivity, (Ix) Trust, (X) Imagination, (Xi) Shrewdness, (Xii) Confidence, (Xiii) Radica Alism, (Xiv) Self-Sufficiency, (Xv) Self-Sentiment And (Xvi) Tension. Additional Derived Scales Include Five Second Order Factors— Extraversion, Anxiety, Tough Poise, Independent And Social Control Plus Composite Score For Creativity, Adjustment, Leadership And Numerous Other Criteria Related Scales. Lt Is Widely Used In Industry’And Business For Selection, Placement, Training And Promotion Of Personnel. Lt Also Facilitates Accurate Diagnosis And Effective Treatment. Range 16 Years And Above. Forms A And B Are Equiva Lent Forms Of 187 Items, Untimed, Requires 45-60 Min, Forms C And D Are Equivalent Forms Of 105 Items, Meant For 15+ And Adult, Untiined, Requires 25-30 Min Land Form E Of 128 Items, Is For Low Literates. Manual Also Includes Norms Table. Form A/B/C/D/E (Any One) , Childrens Personality Questionnaire By Porter And Cattell (Cpq-Pc) (English, Indian Print):((The Cpq Measures 14 Primary Traits Useful In Understanding And Evaluating The Course Of Personal, Social And Academic Development, Plus Traits Related To Creativity. Traits Measured By Cpq Include Emotional Stability, Self-Concept Level, Excitability And Apprehension, Scores For Extraversion, Anxietyety And Other Broad Trait Patterns Are Also Obtained As Combination Of The Primary Scales. It Is Meant For Age Groups Between 8-12 Years. Each Form Has 140 Items. Time Required Is 30 To 60 Min Per Form. Minimum Reading Level Is 4Th Standard) , High School Peronality Questionnaire By S.D. Kapoor (English):(Form-A Or B. Jr-Sr. Hspq Measures14 Primary Personality Dimensions -(I) Warmth, (Ii) I Ntelligence, (Iii) Emotional Maturity, (Iv) Excitabilty, (V) Assertiveness, (Vi) Enthusiastic,(Vii) Su Per Ego Strength, (Viii) Venturesome, (Ix) Dependent, (X) Individualistic (Xi) Depressive, (Zii) Self Sufficient, (Xiii) Controlled, (Xiv) Tense. It Contains T42 Iteras Ia Each Form And Is Meant For Age 12-18 Years. Time Required Is 40 Min. (A)Test Booklets (A Pkt. Of 20) (B)Test Profile (A Pkt. Of 100) (C)Manual (D)Answer Sheets (A Pkl. Of 100) (E)Scoring Key) , Adolescent Problems Scale By H.D. Badami (English}(: The Present Problem Inventory Is College Level And Post-Graduate Level. No. Of Items 265. In This Test 9 Areas Measuring- 1. Physical Health And Fitness, 2. Self And Self-Image, 3.Economic And Mate Rial Facilities, 4. Friendship, Sex And Marriage, 5.Family, 6. Social, 7. Educational, 8. Vocational, 9. Custom, Morality & Religion. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Sex-Role Inventory By Madhu Asthana And O.P. Chaudhary (Hindi/English (No. Of Items Are 60. (A)Manual (B)Test Booklets (A Pkt. Of 100) (C)Scoring Key) , Eysenck Personality Inventory By H.J. Eysenck And Sybil B.G. Eysenck (English} (: (A)Test Booklets (A Pkt. Of 100)(B)Manual) , Eysenck Personality Inventory (Epi) By G.P. Thakur (English):(No. Of Items Are 57. (A)Test Booklets (A Pki. Of 100) (B)Manual (C)Scoring Key) , Temperament Scale (For Chidlren) By J.D. Murjani (Hindi/English):)(For Age Group 8 14 Years. No. Of Items 30. Ten Dimensions Are Measuring Sociability, Tolerance, Aggressiveness, Warmth,Responsibility, Impulsivity, Cheerfulness, Vigorous, Co- Operativeness, Persistence. (A)Test Booklets (A Pit. Of 100) (B)Manual) , The Inferiority Questionnaire By G.C. Pati (English)(It Is A 20 Item Test.Validity Coefficient Against ’Self-Rating’ Is 0.717 And Reliability (Test-Retest) Is 0.920. Scheme For Qualitative Interpretation Of Scores Provided. (A)Test Sheets (A Pkt. Of 100) (B}Manual) , Coping Strategies Test (2001) By A.K. Srivastava (Hindi/English):(Age Group 11 To 18 Years. No. Of Item Are 50. Five Major Categories Measure - Behavioural-Approach, Cognitive-Apprroach, Cognitive- Behavioural Approach, Behavioural- Avoidance,Cognitive Avoidance. (A)Test Booklets (A Pkt. Of 100)(B)Manuai) , Aggression Questionnaire By G.C. Pati (Hindi/English):(It Is Composed Of 16 Multiple Alternative Type Of Answer. Its Ratio Is 0.71 And Validity Against External Criterion Is 0.828. Scheme For Qualitative Interpretali On Of Scores Is Provided. The Questionnaire Consists Of 16 Questions. (A)Test Booklets (A Pkt. Of 100} (B)Manual) , The Dependence Proneness Scale By Jai B.P. Sinha (Hindi/Englisb):(There Are Four Areas - Affection- Affiliation, Lack Of Internal Control, Evading Responsibility And Conformity; To Be Rated On A 5 Point Likert Scale. Its Reliability Coefficient Is .94. Individual Administration Is Advised. Validity Has Been Established Against Many Experimental Situations. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Self-Esteem Questionnaire By Minakshi Biswal (English)(No. Of Items 50. Age Group 15-25 Years. It Can Be Used For Any Behavioural Research Concerning Self Esteem, Survey Purpose/For Comparison Of Population. It Gives A Quick Measure Of Self-Esteem For Experimental Purposes. It Is Suitable For Group Administration As Well As For Individual Testing. The Test Is Developed And Standardized On An Indian Sample. (A) Test Booklets (A Pkl. Of 100 B) Manual) (1 Pair) (D)Manual) , The Self-Confidence (S-C) Scale By M. Basavanna (English):(It Is A 100 Item Scale In T & F Type. It Is Designed To Estimate The Level Of Self-Confidence Among Adolescents And Adults. Corrected Split-Half Reliability Is 0.94. Validity In The Form Of Item Validity And Against Other Experimental Indices Is Established. The Test Booktlet Is Reusable. (A)Test Booklets (A Pkt. Of 20) (B)Answer Sheets (A Pkt. Of 100) (C)Scoring Key (1 Pair) (D)Manual) , Self-Esteem For Children By Anand Kumar (English):(A Set For Children Contains 50 Items And The Following 4 Subscales: 1.General Self-Esteem, 2. Social Self- Esteem, 3. Academic Self-Esteem, 4. Parental Self-Es Teem. Age Group 8 To 15 Years. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Self-Concept Inventory (Adults) By Beena Shah (English):(No. Of Items Are 64. Age Group 21 To 50 Years. 10 Dimensions Measured In This Test Are - 1. Social Self Concept, 2. Emotional Self-Concept, 3. Physical Self-Concept, 4. Cognitive Self-Concept, 5. Aesthetic Self-Concept, 6.Political Self-Concept, 7. Job Related Self-Concept, 8. Self-Coafideoce, 9. Beliefs And Traditions, 10. Personality Traits. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Personality Assessment Ranking Method By N.K.Jain (English)((A}Ranking Sheets (A Pkt. Of 100)(B)Manuai) , Multi-Dimensional Assessment Of Personality Scale (Map Series) By Sanjay Vohra:(Map Is A Series Of Tests Ranging From Children Of Primary Level To Normal Adult Personality. Lt Is Used To Analyze/Report Individual Differences In Personality. The Map Series Has Four Forms For Different Levels (Map Form A, T, C And P) , Sentence Completion Test By L.N. Dubey & Archana Dubey (English):(This Test Consists Of 50 Items. It Maeasures Certain Personality Traits — Sociability, Self Confidence And Ambitions. All The Sentences Are So Framed That They Lead To Reveal The Positive Or Negative Aspects Related To Ones Trait. Age Range 14 To 19 Years. (A)Test Booklets (A Pkt. Of 100)(B)Manual0 , Draw-A-Man Test By Pramila Pathak (Age 2.5 To 16 Years.( , Thematic Apperception Test With Manual By H.A. Murray (Original)(Age 14+ Years): , Indian Adpatation Of Children Apperception Test With Manual:((Cat) By Uma Choudhary. Age 4 To 10 Year.) , Indian Adpatation Of Thematic Apperception Test With Manual (Tat) By Uma Choudhary(: Age 15+ No. Of Cards 14 With One Blank:) , Children Apperception Test By Bellack & Bellack (Original) (Cat):(The Cat Consists Of Ten Pictures Depicting Animals In Various Situations. It Is Used With Children Of Both The Sexes Primarily Between The Ages Of 3 To 10 For Maximal Usefulness. It Is Designed To Facilitate Understanding Of A Childs Relationship To His Most Important Figures And Drives. A) Animal Figure B) Human Figure C) Supplementary) , Rorschach Inkblot Test:(With Psychodiagnostic Plates, Record Blank, Location Chart And Manual By Herman Rorschach.) , Indian Adpatation Of Rosenzweig Picture Frustraction Test (Children) By Udai Pareek:(English)(: For Age Group 4 To 13. (A)Test Booklets (A Pkt. Of 20) (B)Record Sheets (A Pkt. Of 50) (C)Manual) , Peer Pressure Scale By Kusum Tyagi & Nidhi Gupta (English)(: Age Group 12 19 Year. No. Of Items 50. This Test Measures 5 Areas - 1. Interpersonal Relationsbip, 2. Agreeableness, 3. Economic Pressure,4. Academic/Scholastic And 5. Consientioun Sess. (A)Test Booklets (A Pitt. Of 100) (B)Manual) , Tweezer Type Dexterity Test:(Teak Wood Base With Rust Proof Metal Square Top Witb 100 Holes. 100 Needles Provided With A Fine Tweezer.) , Manual Dexterity Test:(Plywood Made With Sockets And 60 Pegs. Painted Or Polished And Fine Finish.) , Finger Dexterity Test :(Box Type.) , Threading Test:(The Device Is Employed In Testing The Speed And Dexterity In Finger Movement. The Time Required To Pass A Thread Through An Eye’ Of 33 Rods, Three In A Row And 11 Rows, Is Measured. The Quality Of Performance Can Also Be Checked Easily.) , Complete Minnesota Dexterity Test:(This Test Measures Simple Hand-Eye Coordination And Gross Motor Skills. It Consists Of A Battery Of Five Tests: Placing, Turning, Displacing, One- Hand Turning And Placing, And Two- Hand Turning And Placing. This Test Comes Complete With Two Folding Pegboards, 60 Blocks.) , Whipples Tapping Board: (This Apparatus Demonstrates One Of The Most Elementary Psychomotor Skills. The Task Is Simply To Tap The Stainless Steel Plates As Rapidly As Possible. Designed For Versatility And Durability, This Unit May Be Used To Demonstrate A Number Of Important Principles) , Hand Coordination Test (Electrically Operated):(Used For Teaming Experiments Of Two Hand Coordination, Consists Of Mechanical Device Permitting Horizontal And Vertical Movements Of A Pin Or A Pencil Through Slot Ted Design. Time And Errors Are Counted. Using Impulse Counter Cumulative Record Of Errors Can Be Assessed. 389. Minnesota Rate Of Placin) , Eye Hand Co-Ordination Test (Drever & Collins Model):(A Semi-Circular Hand Plywood Is Covered On One Side By An Iron Sheet. A Scale Is Mounted On Which The Rider Is Moved On Both The Sides Except The Blind Zones. The Subject Sits With His Chin Resting On Chin Stand. Fine Finish With Pointer And The Rider.) , Speed And Accuracy Test (English):((A)Numerical Sheets (A Pad Of 100)(B)Alphabetical Sheets (A Pad Of 100) (E)Manual) , Social Maturity Scale By J. Bharatraj (English):(For Age Level From 0 To 15 Years. A) Test Booklets (A Pkt. Of 100) B)Manual) , Social Cognition By N.K.Jain (English):((A)Stimulus Material (A Pkt. Of 100)(B)Scoring Template (A Pkt. Of 100) (C)Manual) , Environmental Awareness Questionnaire By Sunita Singh (Hindi/English)(:For Secondary Level To P.G. Level. The Questionnaire Contains 32 Items From Different Areas Related To Measuring Of Environment, Case And Effect Of Pollution And Prevention. It Has High Reliability (0.87). The Validity Has Been Ensured Through Experts Opinion. Percentage Score Norms Have Been Provided. (A) Test Booklets , Inter Personal Attraction By Ripunjay Deo Singh & Vikas Kumar (Hindi/English):(No. Of Items Are 34. Dimension/Factors Are 1. Interactional Factors, 2. Personal Factors, 3. Personality Factors, 4. Physical Factors, 5. Situdational) , Rumour Analysis By N.K.Jain (English)((A)Stimuius Material (A Pkt. Of 100) (B)Scoring Template (A Pkt. Of 100) (C)Manual) , Sociometric Choice Test By Meera Joshi & Jagdish Pandey (English):(This Test Records Interpersonal Attractions Among The Members Of A Group. The Test Should Be Used With A Group Of Persons Who Have Been Together Long Enough To Be Acquainted With One Aaother, Such As In A Class, In A Factory, Club, Etc. Each Individual Is Asked To Choose Five Group Members With Whom He Would Like Most And Also Dislike Most To Study, Play, Sit Or Work, Lunch And Walk. The Names Are To Be Written According To Their Choice Positions. The Choices May Be Interpreted Either In Manner Of A Sociogram Or On The Basis Of Ratings On The Preference Scale Continuum. (A)Test Booklets (A Pkt. Of 100) , Impression Formation By Photographs By Meera Joshi & J. Pandey (Hindi/English):((A)Cards (B)Answer Sheets (A Pkt. Of 100) (C)Manuai) , Aids Awareness Questionnaire By Madhu Asthana (Hindi/English):Lthy Personality. A) Test Booklets (A Pkt. Of 100) B) Manual((A)Manual (B)Test Booklets (A Pkt. Of 100)) , Indian Adaptation Of Hutts Bender Gestalt Test For Adults By C.B. Dwivedi &Subhara Banerjee:(This Adaptation Provides Scoring Instructions For 17 Pathological And For The Adienceabience Scale. It Is Highly Useful For A Quick Understanding And Screening Of Psychopathological Cases. Normative Data Have Been Provided For The Mentioned 17 Pathological And Adolescent-Abience Scale Separately. (A)Manual (B)Test Cards (Per Set) (E)Lndividuai Response Sheet (A Piit. Of 100) (D)Test Booklets (A Pkt. Of 100) , Occupational Role Stress Inventory By Udai Pareek (English):((A)Test Booklets (A Pitt. Of 100)(B)Manuai) , Job Anxiety Scale By M.M. Sinha And A.K. Srivastava (English):(The Scale Comprises 80 Items Which Reveals Employees Anxiety Being Manifested In The Context Of Following Seven Components Of The Job (1) Security- Job Security And Safety, (2) Recognition, (3) Human Relations At Work, (4) Reward And Punishment, (5) Self-Esteem, State Punishment, (6) Self-Esteem, Self-Image, (7) Future Prospects, (8) Capacity To Work. The Scale May Be Administered To The Employees Operating In Production As Well As Non Production Organisations. The Scale May Be Conveniently Used For Research, Survey And Diagnostic Purposes. Split-Half Reliability Is 0.92, And Test-Retest Reliability Is 0.94. The Test Was Validated Against Sinha Anxiety Scale (R-0.54), Sarasons General Anaiety Scale (R-0.56), Taylors Manifest Anxiety Scale (R 0.48). (A)Test Booklets (A Pkt. Of 100) (B)Manual ) , Creative Behaviour Questionnaire By A.P. Singh & L.K. Mishra (2009, English)(No. Of Items Are 13 For Manager) , Intrinsic Work Motivation Questionnaire By A.P. Sngh& L.K. Mishra (2009, English):(No. Of Items Are 12. For Employee.) , Audio Visual Aids Chart Types Of Modern Indian Education . Models Of Teaching History And Development Of Indian Education School Of Psychology Theories Of Personality Theories Of Intelligence Theories Of Learning Major Schools Of Philosophy Schools Of Indian Philosophy Physiological Charts: A Set Of 7 - Eve, Ear, Brain, Skeleton, Nervous System, Human Body, Blood Circulation) , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) David Weehsler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) H.I Eysenck, , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Kuri Lewin , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Alfred Binet , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Wilhelm Wundt , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Gordon Allpor , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) B.F. Skinner , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Sigmund Freud , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edward L.Throndihe , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Ivan P. Paxlov , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jean Piaget, , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Wolfiang Kohler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edwin Guthrie , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Carl Gustav’ Jung , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Raymond Bernard Catteii , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John B. Watson , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Herman Rorschach , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Carl Rogers , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Hermann Ebbinghaus , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Abraham Maslow , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Aristotle , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Erin H. Erikson , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Rollo May , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Albert Bandura , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Lewis Terman , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Henry Murray , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Roberi Pluichik , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Alfred Adler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Hefimann Von Helinholtze , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William James , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John Dewey , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Herbert Spencer , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John Friedrich Herbart , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jean Jacques Rousseau , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Johann Heinrich Pestolozzi , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Friedrich Frobel , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Max Wertheimer , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Rene Descartes , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Plato , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Socrates , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Maria Montessori , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) B.Russell , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Francis Galton , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William Mcdougall , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edward C. Tolman , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Louis Leon Thurstone , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William Heard Kilpatrick , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Gastav Theodor Fechner , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Ernst H. Weber , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Charles Robert Darwin , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jerome Seymour Bruner , Blind Goggles , Metronome:With Bell (Imported)
Contract Date: Jun 27, 2026 Contract Value : 4.95 Lakh
Local Bodies No of Bidders 5
5.
Civil Aviation #11350032 Technical Bid
Tender for Supply Installation Testing and Commissioning of Data Center Infrastructure At Cial. , Precision Air Conditioning System (13 Tr) At Data Centre 2 (Terminal 3) , Supply Of Pac( 13 Tr) As Per Tender Spec , Itc Of Pac( 13 Tr) As Per Tender Spec , Supply Of Lowside Works For Pac( 13 Tr) , Itc Of Lowside Works For Pac( 13 Tr) , Dismantling Of Existing Pacs, Including Outdoor Units , Precision Air Conditioning System (6 Tr) At Dr (Atc Building) , Supply Of Pac( 6 Tr) As Per Tender Spec , Itc Of Pac( 6 Tr) As Per Tender Spec , Supply Of Lowside Works For Pac( 6 Tr) , Itc Of Lowside Works For Pac( 6 Tr) , Dismantling Of Existing Pacs, Including Outdoor Units , Intelligent Power Distribution Unit(Ipdu) , Supply Of Ipdu As Per Tender Spec , Itc Of Ipdu As Per Tender Spec , Equipment Rack And Tap-Off Boxes , Supply Installation Testing and Commissioning of Equipment Rack (42 U) , Supply Installation Testing and Commissioning of Tap-Off Boxes , Very Early Smoke Detection Apparatus(Vesda) System In A Data Centres , Supply Of Vesda System For Dc 1 & Dc 2 , Itc Of Vesda System For Dc 1 & Dc 2 , Supply Of Vesda System For Dr , Itc Of Vesda System For Dr , Water Leak Detection System In A Data Centres , Supply Of Water Leak Detection System For Dc 1 & Dc 2 , Itc Of Water Leak Detection Systemfor Dc 1 & Dc 2 , Supply Of Water Leak Detection System For Dr , Itc Of Water Leak Detection System For Dr , Air Purification System In A Data Centres , Supply Of Air Purification System For Dc 1, Dc 2 & Dr , Itc Of Air Purification System , Data Centre Infrastructure Management (Dcim) System , Supply Of Dcim Hardware , Itc Of Dcim Hardware , Supply Of Dcim Software , Itc Of Dcim Software , Supply Installation Testing and Commissioning of Monitoring Nodes With License , Fire Alarm & Suppression Systems For Dc 1 & Dc 2 , Supply Installation Testing and Commissioning of Gas Release Panel , Supply Installation Testing and Commissioning of Cylinder(80 Litre) , Supply Installation Testing and Commissioning of Clean Agent , Supply Installation Testing and Commissioning of Master Multi Cylinder Kit , Supply Installation Testing and Commissioning of Slave Cylinder Kit , Supply Installation Testing and Commissioning of Manifold Assembly , Supply Installation Testing and Commissioning of Non-Return Valves (Nrvs) , Supply Installation Testing and Commissioning of Pressure Switch , Supply Installation Testing and Commissioning of Abort Switch , Supply Installation Testing and Commissioning of Manual Release Switch , Supply Installation Testing and Commissioning of Conventional Multi Detector , Supply Installation Testing and Commissioning of Response Indicator , Supply Installation Testing and Commissioning of Hooter Cum Strobe , Supply Installation Testing and Commissioning of Copper Armoured Cable , Supply Installation Testing and Commissioning of Cylinder Strap , Miscellaneous Items(Like Sign Stickers, Packing Charges & Modification Of Existing Of Ms Seamless Pipe) , Fire Alarm & Suppression Systems For Dr , Supply Installation Testing and Commissioning of Gas Release Panel , Supply Installation Testing and Commissioning of Cylinder(80 Litre) , Supply Installation Testing and Commissioning of Clean Agent , Supply Installation Testing and Commissioning of Master Multi Cylinder Kit , Supply Installation Testing and Commissioning of Slave Cylinder Kit , Supply Installation Testing and Commissioning of Manifold Assembly , Supply Installation Testing and Commissioning of Non-Return Valves (Nrvs) , Supply Installation Testing and Commissioning of Pressure Switch , Supply Installation Testing and Commissioning of Abort Switch , Supply Installation Testing and Commissioning of Manual Release Switch , Supply Installation Testing and Commissioning of Conventional Multi Detector , Supply Installation Testing and Commissioning of Response Indicator , Supply Installation Testing and Commissioning of Hooter Cum Strobe , Supply Installation Testing and Commissioning of Copper Armoured Cable , Supply Installation Testing and Commissioning of Cylinder Strap , Miscellaneous Items(Like Sign Stickers, Packing Charges & Modification Of Existing Of Ms Seamless Pipe) , Buy Back Of Existing Pacs And Fire Suppression System At Dc 2 And Dr. , Comprehensive Annual Maintenance Contract For 2 Years, Inclusive Of Spares And Accessories. annual maintenance contract Starts After The Warranty Period Of 5 Year. All Amounts In Rs Are Inclusive Of All Taxes, Levies, Transportation, Etc. , 1St Year Manpower Charges , 2Nd Year Manpower Charges , 3Rd Year Manpower Charges , 4Th Year Manpower Charges , 5Th Year Manpower Charges , 6Th Year Manpower Charges , 7Th Year Manpower Charges , 1St Year Maintenance Charges , 2Nd Year Maintenance Charges , 3Rd Year Maintenance Charges , 4Th Year Maintenance Charges , 5Th Year Maintenance Charges , 6Th Year Camc , 7Th Year Camc
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
7.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
8.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
9.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
10.
Defence #11286957 Technical Bid
Tender for Sch A Part- I To Ix: Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated As Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Dg Set) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Schedule A Part-X (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard/ Volina , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 100 Kva/80 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 100Kva/80 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: , Note For Item No. 11.30 (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 126.8 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 100 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 100 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 100 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms , (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 100Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 160A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 160A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 100 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , S&F Square Profile Led Lighting Fixture With Extruded Polycorbonate, Environmental Friendly, Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. Make:Havells Led Pride Essential Cat No Lhexawp7un1w020 Or Equivalent Makes Cg/Philips/Wipro/Luker. , S&F Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door: Plain 6 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 125 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , M&L For Cutting Of Existing 40 Mm Dia Pipe For Inserting Tee Of Size 40X40x20 Mm Including Lead Joint And Excavation Etc Complete, All As Specified And As Directed , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 250 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. Incoming :- (A) Mccb 4 P, 415 Volt 160 Amps, 32Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing :- (B) Mccb 4 P, 415 Volt 125 Amps, 25Ka, 50 Hz -01 Nos. (C) Mccb 4 P, 415 Volt 63 Amps, 10 Ka, 50 Hz -02 Nos. (D) R,Y,B Indicators (E) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 13
Maharashtra View Result →
11.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
12.
Public Administrative Department #11200347 Technical Bid
Tender For Supply Of Electrical Materials On Annual Rate Contract. , 1 Sq.Mm F.R Copper Pvc Insulated Wire. , 2.5 Sq.Mm F.R Copper Pvc Insulated Wire. , 4 Sq.Mm Fr Copper Pvc Insulated Wire. , 6 Sq.Mm Fr Copper Pvc Insulated Wire. , Mains With Isi Mark Wp 2 X 2.5 Sq.Mm. 1100 V Grade Aluminium Pvc Insulated Cable. , Mains With Isi Mark Wp 2 X 4 Sq.Mm. 1100 V Grade Aluminium Pvc Insulated Cable. , Mains With Isi Mark Wp 2 X 6 Sq. Mm.1100 V. Grade Aluminium Pvc Insulated Cable. , Retrofit T8 Led 18 / 20 Tube Light. , Ceiling Rose / Batten Holder /Slanting Holder /Hanging Cord Switch / Hanging Bell Push/ Pendent Holder Bakelite Base 6A. , Street Light Bracket Made From 25 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length With Clamps For Suitable Pole. , Street Light Bracket Made From 32 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length With Clamps For Suitable Pole. , Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length With Clamps For Suitable Pole. , Condenser 2.5 Micro Farad For Ceiling Fan. , Ceiling Fan Of 600Mm. Sweep Complete , Ceiling Fan Of 900Mm. Sweep Complete , Energy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm Complete , Ceiling Fan 230 V A.C. 50 Cycles 1400 Mm Complete , Double Pole Metal Clad Switch With Hc Type Fuse 240V, 63A , Triple Pole Metal Clad Switch And Fuse 415V, 100A , Spmcb 0.5A To 5A, C-Series , Spmcb 6A To 32A, B- Series (For Lighting) , Spmcb 40A To 63A, B- Series (For Lighting) , Tpmcb 6 A To 32A , 3 Pole Mccb Upto 100A, 415V, With Short Circuit Rating 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/ Uv/ Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure. , 3 Pole Mccb Upto 200A, 415V, With Short Circuit Rating 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/ Uv/ Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure. , Hc Pattern Porcelain Fuse Bridges With Base & Hc Type Fuse Links 240V 16A Erected On Polished Wooden Block Complete , Hc Pattern Porcelain Fuse Bridges With Base & Hc Type Fuse Links 240V 32A Erected On Polished Wooden Block Complete , Porcelain Fuse Bridges With Base Hc Type Fuse Links 240V 63A Erected On Polished Wooden Block Complete , Porcelain Fuse Bridges With Base Hc Type Fuse Links 415V 100A Erected On Polished Wooden Block Complete , Porcelain Fuse Bridges With Base Hc Type Fuse Links 415V 200A Erected On Polished Wooden Block Complete , Xlpe Armoured Cable 2 Core 6 Sq.Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm , Xlpe Armoured Cable 2 Core 10 Sq.Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm , Xlpe Armoured Cable 2 Core 16 Sq.Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm , Xlpe Armoured Cable 3½ Core 25 Sq.Mm. Aluminium Conductor , Xlpe Armoured Cable 4 Core 6 Sq.Mm. Aluminium Conductor , Xlpe Armoured Cable 4 Core 10 Sq.Mm. Aluminium Conductor , Xlpe Armoured Cable 4 Core 16 Sq.Mm. Aluminium Conductor , Gi Earth Wire Of High Purity Of Different Sizes Used For Earthing Or Any Other Purposes , Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is:47705 Suitable For Working Upto 22 Kv Supply Complete. , Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. , Electronic Type Cordless Call Bell Erected On T.W. Board Having Portable Bell Push Working On 9V D.C. Battery And (Effective Range Upto 45 Meter) Bell On 250 V A.C.Supply , Electronic Type Step Regulator For Ceiling Fan 600/ 900/ 1200/ 1400 Mm. Sweep, Complete , Double Pole Isolator Only Switch Version Of Miniature Circuit Breaker Of 40A , Triple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 63A , Triple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 100A , Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16A To Use Independently Or In Conjunction With Contactor. , Two Pole Power Contactor 230 V, 12 A For Time Switch Complete , Two Pole Power Contactor 230 V, 32 A For Time Switch Complete , Four Pole Power Contactor 430 V, 16 A For Time Switch Complete , Four Pole Power Contactor 430 V, 40 A For Time Switch Complete , Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On And Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer , Modular Type Switch 6A / 10A , Modular Type Switch 16A , Modular Type 3 Pin 6A Multi Socket With Safety Shutter , Modular Type 3 Pin 16A Multi Socket With Safety Shutter , Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 2 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 4 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 8 Module , Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module , Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 2 Ways (2 Poles) For Outgoing Sp Mcbs , Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 6 Ways (6 Poles) For Outgoing Sp Mcbs , Exhaust Fan Heavy Duty 230 V, A.C. 50 Cycles 375/380 Mm. 900 Rpm , Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225Mm. 1400 Rpm , Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 375/380 Mm. 1400 Rpm , Cabin Fan Of A.C. 230 V. 50 Cycles 250 Mm./300 Mm. Sweep , Cabin Fan Of A.C. 230 V. 50 Cycles 400 Mm. Sweep , 3W, 230V Integral Type Led Lamp Suitable For B-22 / E27 Base , 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , 18W, 230V Integral Type Led Lamp Suitable For B-22 / E 27 Base , Pvc Trunking (Pvc Casing-N-Capping) Of Size 20 Mm , Pvc Trunking (Pvc Casing-N-Capping) Of Size 32 Mm , Hms Pvc Conduit Frls Grade 20 Mm Dia. , Hms Pvc Conduit Frls Grade 32 Mm Dia. , Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Single Phase Input & 1 Phase Output 3 Kva Capacity Online Pure Sine Wave Ups , 12V/26Ah Smf Battery With Battery Terminal Wire , Led Flood Light Fitting Max. 30W Ip65 & Ik07 Class. , Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class. , Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class. , Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class. , Led Flood Light Fitting Max. 120W Ip65 & Ik07 Class. , Led Flood Light Fitting Max. 150W Ip65 & Ik07 Class. , Led Street Light Fitting 18 To 22W Ip65 & Ik08 Class. , Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class. , Led Street Light Fitting 26 To 30W Ip65 & Ik08 Class. , Led Street Light Fitting 40 To 50W Ip65 & Ik08 Class. , Led Street Light Fitting 60W Ip65 & Ik08 Class. , Led Street Light Fitting 70-75W Ip65 & Ik08 Class. , Led Street Light Fitting 85-90W Ip65 & Ik08 Class. , Led Street Light Fitting 100-110W Ip65 & Ik08 Class. , Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete , Plywood 18/19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete , Single Phase, 240V, Street Light Control Panel Up To The Max Load Of 6Kw, Spn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Backup. , Single Phase, 240V, Street Light Control Panel Up To The Max Load Of 12Kw, Spn Mcb 63A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Backup. , Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 6Kw, Tpn Mcb 40A. , Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 12Kw, Tpn Mcb 63A. , Mcb Type Change Over Switch 2 Pole, 25A With 3 Positions , Mcb Type Change Over Switch 2 Pole, 40A With 3 Positions , Mcb Type Change Over Switch 2 Pole, 63A With 3 Positions , Mcb Type Change Over Switch 4 Pole, 25A With 3Positions , Mcb Type Change Over Switch 4 Pole, 40A With 3 Positions , Mcb Type Change Over Switch 4 Pole, 63A With 3 Positions , Led Square / Circular Max. 7W Down Lighter/ Panel Light. , Led Square / Circular Max. 11 W Down Lighter/Panel Light. , Led Square / Circular Max. 14 W Down Lighter/Panel Light. , Led Square / Circular Max. 18 W Down Lighter/Panel Light. , Led Square / Circular Max. 25 W Down Lighter/Panel Light. , Led Panel Light (600Mm X 600Mm) Max. 30 W. , Led Panel Light (600Mm X 600Mm) Max. 35 W. , 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) , 75 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) , 90 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) , Frp Box Of Size 150Mm X 125Mm X 100 Mm, 2.7 Mm Thick Complete , Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete , Frp Box Of Size 300Mm X 200Mm X 125 Mm, 2.7 Mm Thick Complete , Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. , Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.7Tr To 2.0Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. , 2 Pole Rccb 16/25A, 30/100/300 Ma Sensitivity. , 2 Pole Rccb 40A, 30/100/300 Ma Sensitivity. , 2 Pole Rccb 63A, 30/100/300 Ma Sensitivity. , 4 Pole Rccb 16/25A, 30/100/300 Ma Sensitivity. , 4 Pole Rccb 40A, 30/100/300 Ma Sensitivity. , 4 Pole Rccb 63A, 30/100/300 Ma Sensitivity. , 4 Pole Rccb 80A, 30/100/300 Ma Sensitivity. , Minimum Three & Above Star Rated Submersible Pump Set Of 0.75 Kw/1 Hp With 230 V, 50 C/S Ac Supply Suitable For 100 Mm Dia. Borewell Suitable For 10 To 60 Lpm Discharge At 88 To 33 M Head & Discharge & Delivery Pipe Of Size-32 Mm , G.I. Pipe ‘A Class 40 Mm , G.I. Pipe ‘A Class 50 Mm , G.I. Pipe ‘A Class 75 Mm , Arial Bunch Cable 1 Core For Street Light 16 Sq.Mm. , Arial Bunch Cable 2 Core (Phase + Neutral) For Street Light 16 Sq.Mm. , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 800 To 900Va Digital Pure Sine Wave Inverter With Backup Time Of .... Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete. , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 2500 Va Digital Pure Sine Wave Inverter With Backup Time Of ... Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete. , Supplying And Erecting 12V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. , Led Street / Flood Light Driver Upto 25W , Led Street / Flood Light Driver 26 W To 40 W , Led Street / Flood Light Driver 45 W To 60 W , Led Street / Flood Light Driver 65 W To 70 W , Led Street / Flood Light Driver 75 W To 90 W , Led Street / Flood Light Driver 100 W To 110 W , Led Street / Flood Light Pcb Kit Upto 25W , Led Street / Flood Light Pcb Kit 26 W To 40 W , Led Street / Flood Light Pcb Kit 45 W To 60 W , Led Street / Flood Light Driver 65 W To 70 W , Led Street / Flood Light Driver 75 W To 90 W , Led Street / Flood Light Driver 100 W To 110 W , Flexible Led Rope Light 18M Length Upto 50W Conforming Ip 65 Of Any Colour Including Driver Complete With 1 Year Warranty. (For Install On Street Light Pole In Indian Flag Tricolor). , Pvc Insulated Pvc Round Sheathed 1 Sq.Mm (32 No. X 0.20Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv. , Gate/Garden Light Fitting With 200Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp. , Gate/Garden Light Fitting With 300Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp. , Integral Post Top Lantern Fixtures (Mushroom Type) Suitable For Led Lamp Upto 12 W Consisting Of Clear Acrylic Top Cover, Cast Aluminium Pole Cap Complete With Accessories. , Integral Post Top Lantern Fixtures (Globe Type) Suitable For Led Lamp Upto 12 W Consisting Of Aesthetic Round Clear Acrylic Top Cover, Cast Aluminium Pole Cap. , Integral Post Top Lantern Fixtures (Light House Type) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Maharashtra View Result →
13.
Defence #11200248 Price Bid
Tender for Sch A Part-I To Xii Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch A Part-I (Building And Structures) , Total Amount Of Sch A Part-Ii (Site Clearance, Excavation And Earthwork) , Total Amount Of Sch ‘A Part Iii (Internal Water Supply) , Total Amount Of Sch ‘A Part Iv (Internal Electric Supply) , Total Amount Of Sch ‘A Part V (Road, Path And Culverts) , Total Amount Of Sch ‘A Part Vi (Sewage Disposal) , Total Amount Of Sch ‘A Part Vii (Area Drainage) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Total Amount Of Sch A Part-X (Lightning Protection) , Total Amount Of Sch A Part-Xi (Air Conditioning & Cooling Appliances) , Total Amount Of Sch A Part-Xii (Dg Set) , Schedule A Part-Xiii (Miscellaneous B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 5 Signifies This Fact Only. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Preparation Of Road Surface And Applying Thermoplastic Reflective Paint For Marking Of Minimum 2.0 Mm Thick Single Coat As A Centre Line Or Edge Line Etc, Road Marking N Exc 100 Mm Width Using Thermo Plastic Paint (Hot Application) White/Yellow By Indigenous Modern Propelled Road Marking Machine As Directed Including All Ingredients Such As Binder, Glass Beads, Titanium Dioxide, Calcium Carbonate, Inter Fillers Etc, Thermoplastic Requirement For Glass Beads Shall Be Confirming To Bs-6086 Of Most Specification Including Spraying Of Glass Beads Etc Complete All As Per Manufacturers Instructions And Complete As All Specified And Directed. , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Cutting Existing 80 Mm Dia Pipe For Inserting Tee Of Size 80X80x40 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed. , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 300 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. , Incoming:- (A) Mccb 4 P, 415 Volt 200 Amps, 36Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing:- (B) Mccb 4 P, 415 Volt 100 Amps, 25Ka, 50 Hz -03 Nos. (C) R,Y,B Indicators (D) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 125 Kva/100 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 125Kva/100 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: Make: Kirloskar/Greeves/Cummins , (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 1551 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 125 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 125 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. , (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 125 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 125Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 200A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 200A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 125 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/Aplab/V Guard , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/Aplab/V Guard / Volina , S&F Two-Way Bib Taps 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. Make: Cat No. F1015161 Of Cera Or Techno Commercially Equivalent Model Of Appendix C Makes.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
Maharashtra View Result →
14.
Housing Urban and Rular Development #11162283 AOC
Providing the manpower for electrical preventive and breakdown maintenance Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033for the period of 12 months.- 1 Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033 2 Skill Electrician: 03 Nos per day 3 Semi-Skill Electrician: 03 Nos per day 4 Un-Skill Electrician: 02 Nos. per day 5 Semi-Skill (Lift Operatror cum Attendent): 02 Nos. per day 6 SCOPE OF WORK:-1. The Scope of maintenance of electrical installation includes Routine, Preventive and Corrective Maintenance of L.T. Distribution lines to each floor of all the buildings/ blocks, entire wirings, BDB, PDB, VTPN, LT panels, Feeder Pillar Box, power & distribution cables, fittings & fixtures, Switch Boards, Power and Computer Points, Power outlet of all sorts of Air-conditioning Systems,resetting/ Switching off of Fire detection system during normal operation/ malfunctioning etc., Operation, configuration & repair / replacement of Timers for AC / Compound light, Compound Lighting including high mast, all glow sign and metal sign boards in the campus, Electrical Installations/ distribution up to Switch Board/ Panel of Lift Machine Room & Pump Room and / or Kiosk of Pump for Water Supply system, in the premises of above mentioned site. 7 2. Cleaning & checking of all the fittings & fixtures, Panels, TPN & SPN DBs, SFUs & other Electrical Installations, as well as the Compound Light installations in a regular interval to keep them in a tip-top condition at the cost of the agency and the same must be recorded in log book.3. The checking & repairing of the different types of light fittings, ceiling fans, exhaust fans etc. has to be done by the agency at his own cost (except rewinding of ceiling fans and exhaust fans) including dismantling and re-fixing of the same. (Major materials to be supplied by department). Especially, all the ceiling fans of entire worksite are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut etc. to prevent unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency. Split Pin, once taken out from the installation should not be re-used under any circumstances. Required number of Split Pin and Jam nut should be provided by the agency at their own cost. Building wise Fan register should be maintained as per Performa provided by the department, wherein each and every details of checking, replacement of spares, repairing etc. should be recorded against individual fan and every record should be signed by the attending Electrician / responsible person of the agency, duly countersigned by the concerned J.E. and A.E. 8 4. Measuring of various electrical parameters e.g. Current, Voltage, Temperature of different L.T. panel board, BDBs, Main switches etc., test of Insulation Resistance, Earth Resistance etc. are to be carried out every month and test results are to be recorded in Log book (preventive maintenance). Thermal Imaging Scanner should be used for measuring temperature of electrical equipment regularly to find out any abnormalities and printout of thermal image with date and time stamp should be provided to the concerned J.E. and A.E. In case, any abnormal reading is noticed, the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions in consultation with concerned AE&JE. Thermal image should also be taken after rectification. The engaged agency will supervision overall maintenance works and examine Logbooks for any abnormality and sign the Logbook accordingly5. Switching On/Off of the common service lighting e.g. compound, corridors, staircases etc. and AC machines, Light, Fan etc in closed room like Library, Store, OPD, OT or these are not run beyond Office hours or off day will be the responsibility of the agency. 6.Cleaning of Sub-station rooms,LT Panel rooms,operation of HT switch gear & resetting the protective rekeys in case of any fault occurred will be the responsoibilty by the agency . 9 7. Operation of DG sets & checking and maintenance of AMF panel, Checking of Battery, checking of fuel level of DG Set, Lubricating oil etc, carrying & pouring of Fuel if necessary and maintaining separate log book for DG Set as per given Proforma. For Operation of DG Sets, experienced and skilled operator should be provided8.Llift operation cum attendent including regular cleaning of lifts etc as per direction of EIC.9. Regular dusting and cleaning of fire detection sensors and others parts including reset of fire alarms. 10 TERMS & CONDITIONS:-1. The agency has to depute manpower as directed by the EIC carrying out the maintenance work smoothly with due regard to the safety.Category of Staff:- i) Skilled Electrician --03 (Three) Nos per day ii) Semi-Skill Electrician--03(Three) Nos. per day iii) Un-Skill Electrician: 02 Nos. per dayiv) Semi-Skill (Lift Operatror cum Attendent): 02 Nos per day 11 2. The Maintenance Personnel, deputed by the agency havingvalid Voter Identity/ Adhaar Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Category of Maintenance Personnel Mandatory Requirementa. Skilled Electrician Having Electrical/ Workman Permit i(b), ii & iv issued by Directorate of Electricity, West Bengal.b. Semi-Skilled Electrician Workman Permit i(b) and (ii) issued by Directorate of Electricity, West Bengal.c. Un-skilled Personnel/ Helper Basic knowledge of Electrical works.Also the Superviser of the company should have valid SCC Parts 1,2,3,4,5,6A,7A,7B ,9,11,12. 12 3. Agency must have to submit mandatorily the list of staff mentioning their Name, contact Mobile No., category, along with photo copy Valid Workman Permit, proper identity and address proof etc, in writing to the concerned JE & AE before commencing the work. All the photocopy should be attested and authenticated by the Agency.4) The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the Maintenance Staffs deployed including substitutes.They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE.5) The agency will maintain shift wise attendance register at call center to record the attendance of the staffs on duty which will be authenticated/ verified by the concerned Junior Engineer/ Officer- in-charge. 13 6) The agency shall have to prepare a Duty Roster of the Maintenance Staffs at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE and one copy should be available at the call centre.7)The agency will have to provide proper uniform for his maintenance staff at his own cost and clour of the dress will be decided by the EIC. No staff will be allowed for performing duty without proper uniform. 8) The agency, and all the electricians deputed at worksite must have Mobile Nos. and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay. 14 9) The agency has to provide one GPS activated smart phone dedicated for call center. The cost of the handset and running cost i.e. phone bills have to be borne by the agency. No claim of payment against any telephone bill will be entertained by this department.10) The agency should have a close watch on the attendance of the Maintenance Staffs. In case of absence of any Maintenance Staffs, the agency shall have to arrange for suitable alternative within an Hour, failing which, the charges for that day will be deducted from the bill of the agency on pro-rata basis.The Executive Engineer,Electrical Constrution Division ,P.W.D. reserves the right to terminate the contract in case of absence of Maintenance Staffs for more than three consecutive days, without showing further reason. 15 11) In case of any Accident and or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. Minimum wages as per existing Labor Act should be paid to the Electrician(s) and Helper(s)12) The agency shall have to provide 500V Megger, Digital Multi meter, Earth tester and all other requisite tools and tackles sufficient for checking, testing and recording of health of all electrical installations. Other tools & tackles e.g. Crimping Machine, Line Tester, Screw Driver, Pliers, Stripper, Sockets of some common sizes etc. should also be available at site, in sufficient quantities, free of cost, under disposal of their maintenance staff.Deployed employee by the agency should have sufficient knowledge to operate The Thermal imaging Scanner or to be used by the direction of Assistant Engineer/ Junior Engineer.13) The space for sitting accommodation for the staffs of the agency inside worksite premises will be provided by the competent authority. 16 14) All the maintenance staff of the contractor should have proper & constant vigilance and check that, there is no sign of heating-up, burning smell, discoloration or sparking at any of BDBs, panel boards, rising main etc. due to overloading or loose termination. Care should be taken to check any highly unbalance in loading at any point.15) In case of power failure or development of any unfavorable situation the agency will have to communicate with the concerned Power Supply Company authority and extend help or cooperation to said authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supplies at important locations by monitoring and/ or restricting electrical loads in consultation with the concerned Junior Engineers & Assistant Engineer.16) Routine checking and preventive maintenance and breakdown maintenanceof the electrical installations has to be carried out by the agency maintaining a register under signature of respective Junior Engineer and Assistant Engineer with a view to ensure uninterrupted power supply within worksite campus. 17 17) Materials required as replacement during maintenance of electrical installations e.g. Lamps, SFUs, SPNDB, TPNDB, Cables etc. will be supplied by the Department for which requisition of Materials, signed by the authorized representative of the agency, should be submitted to the concerned JE (Electrical) well in advance. A separate material stock register should be maintained by the agency where entries related to Issue, Consumption & present stock position of Materials should be made. However auxiliary items like fuse wires, screws, nuts, bolts, washers, insulating tape, Split pins of Ceiling Fans, dusters etc. will have to be supplied by the agency at his/ their own expense.18) The agency shall have to deposit all dismantled unserviceable materials such as fused lamps, defective condensers, starters, and timers, MCBs etc. to the concerned Section Office or any other locations within worksite premises by the agency by its own laborers / arrangements / tools and tackles as per the direction of the Assistant Engineer/ JE concerned. Fresh materials will be issued against respective defective materials. No materials should be taken out of the maintenance site without the permission and necessary challan of the site-in-charge/JE 18 19) Any major shut down or fault should be brought to the notice of JE/AE immediately in writing and over telephone for further course of action. The agency will also have to attend emergency calls immediately at the site with staff, tools etc. on demand. 19 20) In case of any breakdown caused by cable fault etc., if situation demands the agency will have to restore the power supply temporarily either with the materials available with this department or arranging the same temporarily and safely at his own cost till completion of original restoration work.21) Building wise Log book is to be maintained for Preventive Maintenance & Cleaning and Corrective Maintenance of Electrical equipment except Fan as per direction of E.I.C. Separate Building wise Register is to be maintained for Ceiling Fans. The daily record of the Log book is to be signed by the responsible person and verified & signed by concerned JE & AE and photocopy of the same should be sent to the Executive Engineer concerned through proper channel at the time of submission of bills. The Logbooks should be available at Call center and should be produced on demand. 20 21) The agency should be responsible for any damage in the installation due to mishandling or mal- operation by its staff and shall be liable for rectification / replacement, as the case may be, of the damaged installation/ equipment within time frame to be fixed by concerned A.E., failing which the said rectification/ replacement of affected equipment/ installation would be executed by external agency and the cost thereof would be recovered from the bill and the accused staff should be replaced immediately.22) Bills should be submitted quarterly with the certification of satisfactory performance of the concerned JE and AE. Photocopy of Logbook and Attendance Register should also accompany the Bill. Payment should be made as per PWD norms. 21 23) Any fault of electrical installations starting from LT supply end (except the installations of Power Supply Company) to light, fan, call bell, plug points etc. i.e. LT cables and all sub-panels, distribution boards, main switches, earthing attachments, compound lights etc. has to be detected, attended and restored by the agency by its own man power with the help of the materials(cables, main switches, DBs, wires, HRC fuses etc.) available from this department or as per the terms & conditions of this contract. 24) If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions causing inconveniences to public service, is subject to unilateral penalty, be it detected on the spot or thereafter (even after payment). This Department also reserves the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge for any shortfall in observing above T&C. In that case, the above- said contract may be terminated without issuing any notice and Stringent & punishable action may be taken against the contractor. 22 25) The technitian of the agency should capable of Casing -caping /rigid conduit wiring to overcome the emergent situation .25) The contract may be terminated with one months’ notice on either side (both agency and tender awarding authority) . 26) At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .27) Any upcoming / Ongoing project, which will be completed within stipulated period of Maintenance contract, automatically will come under maintenance contract .28) All the log-books should be available at the call center and to be produced to the Office of the AE/ JE on demand. 29) This Maintenance contract covers all the buildings, blocks, outdoor electrical gadgets within the premises ofTechnician Studio, Kolkata-700033 23 TERMS & CONDITIONS FOR OPERATION OF LIFTS:- 24 1. The agency has to depute manpower as directed by the EIC carrying out the lift operation smoothly with due regard to the safety.Category of Staff:- Semi-Skill (Lift Operatror cum Attendent): 02 Nos. 25 2. Day to day Attendent -cum -operation of passenger lift foras directed by the EIC.3. The lift operator/attendant should have a sound knowledge with valid lift operator license issued by the Licensing Board, Govt. of West Bengal.4. The operator/attendant should be obliging dutiful and polite to all while on duty. In case any irregularities of duty or complain against the operator/attendant if noticed, would be withdrawn forthwith and shall be replaced by new operator.5. The report is to be submitted periodically about the working of lift incl. all safety devices and Governor to the concerned JE/AE. 26 6. Agency must have to produce the list of the staff mentioning their Name, contact Mobile No.in writing with proper identity and address proof & their Valid lift operator license issued by the Licensing Board, Govt. of West Bengal along with photo copy to the concerned JE & AE before commencing the work. This should be treated as mandatory.7. The agency will have to provide proper dress for his staff and color of the dress will be decided by this department. No staff will be allowed for performing duty without proper dress.8. The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the operation Staffs deployed including substitutes. They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE 27 9. The agency shall have to prepare a Duty Roster of the operation Staff at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE.10. The agency must have separate contact telephone numbers with Mobile Nos. for his office and Supervisor deputed at worksite so that the agency may be communicated in case of any urgency and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay.11. The lift enclosure to be kept clean (not sweepers works) regularly by the operator 28 12. The operational work of the lift is to be supervised directly under the supervision of technical staff of the contractors under the direct control of JE/AE concerned. The contractor shall be responsible for any damage to the lift due to mishandling; loss will be recovered from the contractors bill as per direction of EIC.13. The Log Book recording regarding functioning and breakdown of the lift is to be maintained at site by the contractor under supervisions of JE concerned. If any kind of trouble arises, it should be brought to the notice of JE, AE concerned immediately. The JE/AE would put their signature on log book making note on performance. 29 14. In case of any absence of operator, the lift is to be made operative within 2 hours by placing the new operator. In case of absence prorate deduction will be made from the contractors bill and the contract may be terminated if it exceeds 3 (three) days. In this respect Executive Engineer’s decision will be final.15. This department would not be held responsibility for any accident of the liftman on duty for any reasons. The contractor or their lift operators on duty would not claim any compensation in any shape from this department for such accident. 30 16. The Executive Engineer,Electrical ConstructionDivision, P.W.Dte. would have sole authority to cancel the contract without assigning any reason with a notice of one month only.17. Any conditional quotation offered would not be accepted.18. Any quotation offered with price variation clause would not be accepted.19. The payment will be made monthly/quarterly on submission of bill in triplicate by the agency with satisfactory report regarding performance by the concerned JE/AE. Copy of log book has to be enclosed with the bill. 31 20. Persons entrusted by the agency for operation of lift should wear photo Identity Card during duty hours.21. Documentary evidence in support of payment of minimum wages as per Labour Act to be produced to the Principal Employer i.e. Executive Engineer, Electrical Construction Division, P.W.Dte. in-charge of works.22. Rescue operation is in the scope of agency in case of exigency arises out of lifts getting stopped in between landing floors with passengers inside cage.23. No claim towards cost of uniform, PPE e.g. Hand Gloves, Mask, Goggles, protective body- ware etc. for the maintenance staffs should be entertained by this department. However, if any such equipment/ dress is available from the Hospital Authority for their statutory requirement, the same would be provided. BUT IN NO CASE IT SHOULD BE ENTERTAINED AS MANDATORY CLAIM.24.At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .
Contract Date: Mar 09, 2026 Contract Value : 14.46 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
15.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
16.
Public Administrative Department #11131337 AOC
Providing Fixing Various Equipments And Appliances And Electrification Work In Covid Care Center At Nmc Area .-1 Supplying And Erecting Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body 3 Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete ( Bajaj / Crompton ) 2 Supplying, Installing, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) ( Microtek / Sr ) 3 Supplying And Erecting 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete ( Excide / Felix / Amron ) 4 Supplying, Installing, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. ( Dikin / Hitachi / Samsung / Lg ) 5 Supplying, Installing, Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. ( Jain / Racold / Farmson / Vguard ) 6 Providing And Fixing Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . ( Kent / Aquagrand / Pureit ) 7 Providing And Fixing 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. ( Hikvision / Dlink ) 8 Supplying & Erecting 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp ( Hikvision / Dlink ) 9 Supplying & Erecting 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp ( Hikvision / Dlink ) 10 Supplying & Erecting 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. ( Hikvision / Dlink ) 11 Supplying, Fixing Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder ( Seagate / Wd / Toshiba ) 12 Providing And Fixing 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup ( Microtek / Intex / Iball ) 13 Supplying, Erecting, Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete ( Lg / Samsung / Sony / Vu / Intex / Amstard ) 14 Supplying And Fixing Cat-6 Cable With Rodent Proof Suitable For Lan / Wan ( Hikvision / D-Link / Polycab ) 15 Supplying, Installing & Testing Utp Connector ( Rj-45 ) 16 Supplying, Fixing, And Configuring Broadband Adsl Router With All Accessories, On Provided Rack . ( Dlink / Iball ) 17 Supplying, Fixing, And Configuring 8- Ports Managed Gigabit Switches Poe Smart Switch ( Dlink / Iball ) 18 Supplying And Fixing 6U Wall Mount Rack 19 Supplying & Installing Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. ( Dlink / Hikvision / Polycab ) 20 Supplying And Erecting 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete ( Excide / Amron / Felix / Sf ) 21 Supplying, Erecting, Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 22 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 23 Recharge Of Broadband Connection 24 Making Pumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 25 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 26 Supplying And Fixing Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 27 Supplying, Installing & Testing Utp Connector ( Rj-45 ) 28 Supplying, Fixing, And Configuring Broadband Adsl Router With All Accessories, On Provided Rack . ( Dlink / Iball ) 29 Supplying & Erecting Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . ( Polycab / Dlink ) 30 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling. ( Polycab / Gwpl / Pressfit ) 31 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories ( Polycab / Gwpl / Rr ) 32 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories ( Polycab / Gwpl / Rr ) . 33 Providing And Fixing T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . ( Surya / Crompton / Bajaj ) 34 Providing, Erecting Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 35 Supplying & Erecting 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . ( Surya / Crompton / Bajaj ) 36 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B- 22 / E-27 Base . ( Surya / Crompton / Bajaj ) 37 Supplying And Erecting Regular / Standard Model Ceiling Fan Complete Erected In Position ( Surya / Crompton / Bajaj ) 38 Supplying And Erecting Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 39 Supplying And Erecting ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 40 Supplying And Erecting Isi Mark Modular Type Electronic Step Regulator For Fan ( Anchor / Gwpl / Legrand ) 41 Providing And Fixing 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. ( Sr / Equivalent ) 42 Providing And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation ( Crompton / Bajaj / Havells ) 43 Supplying And Erecting 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete ( Crompton / Bajaj / Havells ) 44 Supplying And Erecting 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete ( Polycab / Gwpl / Finolex ) 45 Supplying And Erecting 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete ( Polycab / Gwpl / Finolex ) 46 Supplying And Erecting Isi Mark Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Polycab / Gwpl / Finolex ) 47 Supplying And Erecting Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Polycab / Gwpl / Legrand ) 48 Supplying And Erecting Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Polycab / Gwpl / Legrand ) 49 Supplying And Erecting Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Polycab / Gwpl / Legrand ) 50 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected ( Polycab / Gwpl / Legrand ) 51 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected ( Polycab / Gwpl / Legrand ) 52 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Modules Complete Duly Connected ( Polycab / Gwpl / Legrand ) 53 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected ( Polycab / Gwpl / Legrand ) 54 Supplying And Erecting Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse ( Polycab / Gwpl / Legrand ) 55 Supplying, Erecting & Marking Dpmcb 40A To 63A, C- Series ( For Motor / Power ) In Provided Distribution Board ( Legrand / Simens / L&T ) 56 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board ( Legrand / Simens / L&T ) 57 Supplying And Erecting Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. ( Samsung / Lg / Whirlpool ) 58 Providing And Erecting Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. ( Atlantis / Jajoo ) 59 Providing And Erecting Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. ( Atlantis / Jajoo ) 60 Providing Premix Of Tea / Coffee For Vending Machine Refillng. ( Amazon / Jajoo ) 61 Supplying And Erecting Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. ( Samsung / Lg / Whirlpool ) 62 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. ( Nokia / Sansung / Jio ) 63 Making Plumbing Works For Fixing Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 64 Providing And Fixing Bracket For Set Top Box 65 Providing Stainless Steel Electric Kettle ( Prestige / Bajaj ) 66 Supplying & Installing Co-Axial Copper Cable Low Voltage Grade Rg-11 67 Supplying And Erecting Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. ( Blue Star / Lg ) 68 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 69 Supplying & Erecting Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 70 Supplying & Erecting Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 71 Supplying And Erecting Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 72 Supplying And Erecting Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 73 Supplying And Erecting Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 74 Supplying And Erecting Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete ( Polycab / Vishal / Finolex / Equivalent ) 75 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 4 Sq. Mm. Copper Conductor Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete 76 Supplying Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv ( Polycab / Vishal / Finolex / Equivalent )
Contract Date: May 20, 2026 Contract Value : 20.00 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
17.
Housing Urban and Rular Development #11118160 AOC
Tender For Modular Operation Theatre Items At Sadar Hospital, Jamtara At Jamtara For The Year-2025-26 , Wall And Ceiling Cladding (Approved Makes: Jindal/Tata/Essar) Prefabricated Wall & Ceiling Prefabbicated Modular Operating Theater Using Ppgi Puf Panel (Both Wall & Ceiling) Providing Of Pre-Fabricated Modular Operation Theater With Ppgi Puf Pannel Filled With Puf Of 40 Kg/Cubic Meter (40D) Having Required Mechanical Strength And Better Thermal Insulation Which Saves Energy Construction The Panels Joints Are Properly Cam Locked & Revisited Which Provides A Seamless Sub- Structure Which Again Sanded To A Smooth Finish. Approx. Thickness For Wall 50 Mm, Raiser 40 Mm. And Ceiling 30Mm. , Laminar Air Flow System Supply Installation Testing And Commissioning Of Ceiling Filtration System 2400 X 2400 Mm. The Ceiling Filtration System Shall Be 2.40 Meters X 2.40 Meters And Will Be Integrated With The Adjacent False Ceiling. The Ceiling Shall Be Constructed With A Plenum Box Supplied With Conditioned Air From The Central System Via 8 Nos.Hepa Filters (European Norm En1822:2009; Class H14; Dop 99.97-99.9999% Efficincy For 0.3 Micron Particles) With Pressure Drop Of 300 Pascals At Its Nominal Flow Rates (Supplied With The Plenum), Mounted On The Exit From The Supply Ducting. , Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Weled With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Hermetically Sealed Sliding Door System Fabrication Supply, Installation, Testing & Commissioning Of Sliding Type Hermetically Sealed Ot Door Having High Density Partical Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Size:1800 X 2100 Mm.(Wx H). Automatice Doors: Provided With Radar Switch- 2 Nos., Foot Switch Nos. And Photocell Sensors (Anti Crush Feature) & As Per Tech. Specs.Attached. Automatice Doors Size:(1800 X 2100 Mm.) , Peripheral Lights Supply Installation And Commissioning Of 42W Bottom Opening Room Fixture With Ip 65, Led Make Should Be Nichia/Seoul5 Sdcm, Own Make Bis Certified Islocated Driver, Flicker Free, Class2 Selv Driver, Operating Temperature:-100C To 450C Operating Voltage Range:140-270V, Surge Protecction 3.5 Kv, High Effciency Driver:80-85%, Low Voltage Cut Off Below 130V, Output Short Circuit Protction, Fixture Made Up Of Ms Power Coated White After Phosphochromate Treatment Provided As Standard With Sheet Thickness Of 1.2 Mm. Diffuser Of High Impact Polycarbonate Opal Diffuser With Thickness 1.5Mm For Glare Freeuniform Light Distribution, Power Coating: 60Microns, Lamp Source: High Efficiency Long Life Led Package In Integral Module To Ensure Better Uniformity, Average Life L70b50: 50000 Hours,Thd10%,95, System Efficacy 95-100 Lm/W, Cri80, Ip65, Ik05 Impact Rating, Dimension Will Be , Surgeon Control Panel Supply, Installation, Testing & Commissioning Of Operation Theatre Control Panel Membrane Type: Time Day Clock Time Elapse Clock General And Rgb Lighting System Conntrol (Peripheral Lights And Plenum Lights With Dimming) Medical Gas Alarm Panel 5 Gas- Low, Normal And High Pressure With Sequencing As Per Htm 02 01 Hand Free Telephone Set With Speaker Temperature & Humidity Indicator With Controller Hepa Filter Status Module Room Pressure Indicator/ Differential Pressure Indicator , X-Ray View Screen Supply Installation, Testing & Commissioning Of Twin Plate Led Xray Viewing Screen: Size:940 X 640 X 50 Mm. Approx With Viewing Area, Two Plate X-Ray View Screen (120W), Led Based Technology With Colour Temperature6000k And Lamp Life50,000 Hrs And Brightness In Excess Of 4000 Lux. , Writing White Board Supplying & Fixing Of Sturdy Writing Operating List Board: Made Of Ceramic Surface Having Magnetic Properties And Should Be Flushed To The Wall Of The Operating Room Size 940Mmx 640Mmx 50Mm , Surgeon Pendant Providing & Fixing Of Ceiling Mounted Single Arm Pendant Systems For Surgeon: The Weight Carrying Capacity Of The Arm Should Not Be Less Than 180 Kgs. Load. There Should Be 5 Or 6 Nos. Equipment Loading Shelves. Double Column Of 1000Mm. Single Arm Pivot Range Minimum 900 Mm. Or Above. The Brake (Electromagnetic) Supplied With Indian Origin Multipin 6/16 Annual Periodical Maintenance Electrical Switch+Socket-5Nos. It Should Have 2 No. Rj 45 Data Socket. It Should Have Provision For 06 Gas Outlet Points 2 Oxygen 1 Sa7 1Co2 1 Vacuum Capable Of 340 Degrees Of Rotation. Medical Gas Terminal Units Shall Be Provded By The Mgps Vendor And Shall Be Installed In The Pendant. Usfda , Anesthesia Pendant Ceiling Mounted Rigid Pendant Systems For Anaesthesia: Single Arm Motorized Type Pendants Made Of Aluminum, Powder Coate Dimensions: Double Vertical Column 1200 Mm. Vertical Lift:600 Mm. Horizontal Arms- Total 1000 Mm. Pendant Should Be Prepiped Provided With 5 Nos. Medical Gas Outlets. Outlets Shall Be Connected To Dual Circuit Being Provisioned For All Ozygen 2 Outlets. Nitrous Oxide 1 Outlets Vacuum 1 Outlets. Medical Air 1 Outlets Agss 1 Outlet Colour Coded High Pressure Tubing For Each Gas With Nist Connectors At Ceiling Provided With Prewired 10 Nos 6/16 Amps Sockets And Two Data Sockets Rj45 Instrument Loanding Capacity 180 Kgs. Shelves: Two With Handle And Two Rail Each With Capacity Of 40 Kgs. Drawers One With Handle And Twe Rails Load Capacity 40 Kgs. Swiveling Stainless Steel Vertical Pole , Air Conditioning System: Ahu Supply, Installation & Commissioning Of Air Handling Unit Make: Vts (8.5Tr) (Out Door Unit Make: Blue Star / Carrier) , Aluminum Duction 22 Gauge With Curves & Bends Where Indicated For Easy Flow Of Air Tight By Applying Silicon Sealant After Fabrication. Hangers Will Be Provided To Ducts & Will Be Suspended Be Means Of G.I. Coated Rod & These With Not Be More Than 2.5 Mtr. Apart. Thermal Insulation With 19Mm. Xpe With Aluminum Foil For Supply & 13Mm. Xpe Return Air Ducts. Joints Will Be Lapped With Nitrile Tape For Better Insulation. (Laminar To Ahu & Return Air In All Four Corners) Ahu To Be Placed Near Ot, Not More Than 6 Meters. , Dustbin (Trio) , Storge Unit: Storge Unit: 1 Mm. Thick Stainless Sheet 304. The Storge Unit Should Be Divided 4 Equal Parts And Eachpart Should Have Indivdual Swing 8 Mm. Toughened Glass Door With Quality Stanless Steel Self- Closing Hinges Capable Of 180 Degree Swing Out And Secure Locking System. Each Part Will Be Provided With Removable Stainless Steel Racks Made From½ Circular ( Outer Diameter) Seamless Stniless Steel 304 Tubes Of 1 Mm. Thickness Placed At Intervals Of 1.5 Center To Center. The Overall Dimension Of The Stroge Unit Shall Be 1500 Mm. (Width) X 2100 Mm. (Height) 350 Mm. Depth Being Variable To Suit Architectural Layout. , Supplying, Installation, Testing & Commissioning Of F Floor Mounted, Scrub Station: Compact Surgical 2 Bay Scrub Sink Designed For Use In Ot Complex. Each Fixture Fabricated From Heavy Gauge 1 Mm. Thick Type 304 Stainless Steel Of Seamless Welded Construction, Polished To A Smooth Finish With A Front Access Panel Which Should Include, Stoppers And Strainers. Hands Free Operation Should Include Infra-Red Sensors With Built-In Range Of Adjustment. Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature. User Defined Setting Of Approximately 1 To 3 Min Should Be Available. (Size 1500Mm. X 675Mm. X 1105Mm. For 2 Persons , Electrical Db Supply Installation Testing And Commissioning Of Electrical Distribution Board: Should The Trandformers, If Any, Mains Failure Relays, Electrical Distrition Equipment And Circuit Protection Equipment For All Circuits Within The Operating Theatre. All Internal Wiring Should Terminate In Connectore With Screw And Clamp Spring Connections Of The Clip-On Type Mounted, On A Din Rail And Labelled With Indelible Propritary Lables, Individual Fuses Or Miniature Circuit Breakers Should Protect All Internal Circuits. , Pressure Relief Damper Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Relief Dampers: Suitably Sized Air Pressure Relief Damper Should Be Placed Endabling Differential Room Pressure To Be Maintained.Counter-Weight Balancing System Should Be Prvided In The Prd To Maintain Positive Pressure Inside The Operation Room , C-9001 Supreme, Sliding Top Electric Table , C-9001 Supreme, Sliding Top Electric Table Led Operating Light Led Operating Light Having Following Specifications:- Maximum Luminance (1M): 160,000+160,000 Lux At 1 M Distance, Electrical Power: 150+90W, Power Consumption 2 X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1 X 3600/ 1 X 3300, Recommended Room Height At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm/650 N, Light Body Weight 9.2 + 7.5 Kgs, Light Body Depth: 1 X 130 Cm / 1 X 140 Cm, Air Shielding Surface 2 X 330 Cm2 Transformers: 2 X 450Va/ 230V/26V, Brightness Regulator 2 X 20- 500Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Done Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs: , Uv System: Uv Rays Are Very Effective In Killing A Large Number Of Pathogenic Organisms Of Bacterial, Viral And Fungi Commonly Seen In Operating Theaters Such As Pseudomonas, Clostridium Difficile, Mrsa And Vre , De- Fumigation System: Fumigation In Operation Theatre Is A Process Of Gaseous Sterillization That Is Used For The Killing Of Micro-Organisms And Prevention Of Micro-Organisms And Prevention Of Microbial Grwth In The Air, The Surface Of The Wall, Or The Floor1.000 De-Fumigation Control Panel Is Installed Outside The Operation Theatre To Monitor The Room Pressure And To Start The De- Fumigation System From Outside The Operation Theatre, It Will De-Fumigation The Theatre In A Given Time And Will Switch-Om The Ahu To Increase Operation Theatre Pressure Without Operating The Surgeon Control Panel , Ot Corridor Area & Ot Complex With Per And Post Area Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Welded With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Antibacterial / Antifungal Paint Providing And Applying Antibacterial Paint The Internal Surface Of The Room Walls Will Be Sprayed With Water Based Liquid Plastic Wall Glaze Or Equivalent Anti- Bacterial Paint, Approved By The Architect To A Mimnimum Dry Film Thickness Of 300 Microns. The Plastic Coating Will Overlap The Floor Covering Ceiling System And Doorframes By 25 Mm. To Provde A Continuous Sealed Surface. The Plastice Coating Will Be Non- Reflective And The Colour Will Be Submitted To The Architect For Approval. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Jun 15, 2026 Contract Value : 1.21 Crore
Government Departments No of Bidders 4
18.
Rural Development #11115805 Price Bid
Tender For Supply ,Fitting And Fixing Of Electrical Materials And Wiring For New Ac Connection At Uttarayan Marriage Hall At Ward No 08 Under Burdwan Municipality - 1 Supplying and fixing 415V, 200A TPN SFU with sheet steel enclosure on flat iron/anglo iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make-LT) for receiving the power of WBSEDCL. PWD-D-3/4,A 100 A 2 Supplying and fixing 415V FP 100A Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make-Havells) PWD-D-1/2 b 3 4 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required-(As per Drawing no. 470 of PWD Specification Book-May 1991. Dimension of bars 4 bers 415 V. 100/125-A [85 mm long 4 x 15 x 3mm Dimension of Sheet Metal Box 500x150mm. PWD-D-13/19.b 2004 Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB Incomer with IP-42/43 protection, on angle iron frame on wall & ruending good the damagee to original finish incl Inter connection with suitable size of copper wire and neutral link & provision for evarthing attachment. 160A 4 way (Make-LT) PWD-D-11/15 125A 5 9 Supplying and fixing 415 V Four Pole 200 A MCCB of Breaking apacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/enclosure and necessary connection. Legrand LT) (Make- PWD-D-8/10 6 Supplying and fixing 240/415V 63 A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make-LT) PWD-D-6/7 7 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the demages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 6 way (Maka LT) PWD-D-10/14 8 Supplying and fixing 415 V 63A FP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make-LT) PWD-D-6/7 Supplying and foxing 240 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make-LT) PWD-D-8/7 10 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module Gi Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. PWD-E17/5.a 11 Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy, connections with PVC Cu wire and earth continuity wire etc.. PWD-E-19/17 12 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections PWD-E-17/5 b 13 8Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing shoot metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/ perspex top cover incl. maaking necy, connections etc. PWD-E-6 item-18.a 14 Supply & Fixing 240 V 6A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required PWD-E-5 Itom-14.a 15 Supply & Fixing 240 V, BA plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy, connections with PVC wire and earth continuity wire etc. PWD-E-5 item-15.a 16 Supply & Foảng 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/porspex cover and making necessary connections as required. PWD-E-5 fiem-14.b 17 Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing shoot metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy connections with PVC wire and earth continuity wire ato. PWD-E-5 Item-15 a 18 Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy PVC clips, fittings etc sqmm) +1 x 22/0.3 (1.5 sqmm) 2 x 22/0.3 (1.5 PWD-E- 11 Item-1. b. 19 Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. nocy. PVC clips, fittings etc sqmm) +1 x 22/0.3 (1.5 sqmm) 2 x 36/03 (2.5 PWD- E-11 item-1.c. 20 Wining in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc 1x36/0.3 (2.5 sqmm) 2 x 56/0.3 (4 sqmm) PWD-E-11 Item-1. e. 21 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid Gi fish wire and making necy. connection as required. 3x126/0.4 (16 sqmm)+2x80/0.4 (10 sqmm) as ECC PWD-E-9 Item-11. 22 Supply ol 2 core 10 sqmm Aluminium-armoured-oable 23 Supply of 4 core 16 sqmm Aluminium armoured cable. 24 Supply of 36 c core 25 sqmm Aluminium armoured cable. 25 Laying-of-cable vpto-2-core 25 soman on wall/surface inch-9&-P MS saddles with earthing attachment in 10 SWG GI (Met Dip) Wire, making hores etc as necy mending good dansager-and painting PWE F2 28 Laying of cable upto 3/4 core 25 sqmım un will/aurisce incl. & & FMS saddles with earthing attachment in 10 SWG GI (Hat Dip) Wire, making holes etc. as necy, mending good damages and painting. PWD-F1 Item-2.b 27 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 3% core 25 sqmm coblo PWD-F4/7.d 28 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 16 core 16 sqmm cabic PWD-F4/7.c 29 Supplying and fixing-compression type gland complete with brass gland, brass-ring-8-rubber ring for dust & moisture-proof entry.of XLPE/PVC-armoured-cables as bolow 2-core-10.comm.cable PWD-F4/7 30 Finishing the end of following XLPE/PVC-armoured cables by crimping method inel-supplying and fixing solderiess.socket (Dewels make) tapes, anticorrosive paste & jointing materials 2-core-10 somm cable PWD-F-5-liem-8-b-(ii) 31 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 16 sqmm cable PWD-F-5 Item-8.b (xi) 32 Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 16 sqmm. PWD-F-5 Item-9 33 S & F 250 V 300 mm sweep Heavy Duty Exhaust Fan, Fixing on existing hole in wall. S & F of louver shutter/cowl on wall with necy bolts & nuts (6 mm dia x 62 mm long) as per GS. (Havells/GP/Crompton B 34 Supply and fixing of surface type LED 15W celing light PHILIPS/Havelis Make philips steak sunfuri 34WD Page-3-4 35 36 Supply and fixing angular batten holder with 9 watt LED lamp on wall. (Philips Make) Supply and fixing 25 watt LED batten light fittings 4ft length. (cat No-BN021 LED 25S 6500 PSU GR S1 Philips Make) 37 Supply-and-forng watt sarlace mounted opot LED light (Philips Havella Syaka Mako) 38 Supply 240 V 110 W outdoor LED fittings (Philips BRP 333 LED 110 CW.RSC.FG PSU STV1) eFS-504-100-30-60D-SL-G -NS M.E.D rettud 39 Supplying and Fixing Gl water proof looping cable box having hinged Gt Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking rrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy, incl. painting 200 x 150 x 100mm. PWD-1-2 Item-16.a 40 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 nim from wall including providing drilled holes on the busbar complete with GI boits, nuts, washers, spacing insulators etc. as required. PWU-G 2 liem-4.a 41 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long Gi bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI Medium Gi pipe. PWD-G-1 Item-2.a 42 Supply and installationof Split type room air conditioning machine of following tonnage capacity 3 Star rating fitted with rotary crompresser and cooling capacity min. 6000 kcal/Hr., mainimum discharge air flow 800 cum mir, 800EER (w/w) 2.7-2.89 (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC. 1.5 Ton 3 Star non-inverter type (Hitachi, Dikien, Carrier Make)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
19.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
20.
Power #11049461 Technical Bid
Tender For Design, Engineering, Supply, Installation, Testing, Commissioning And Annual Maintenance Service For Flood Early Warning System For 37.5 Mw Parnai Hep- 1 Sensor Station For Parnai Project 2 Radar Type River Level Sensor With Tilt Meter Including All Accessories, Software & Mounting Arrangement 3 Radar Type River Velocity / Flow Sensor With Tilt Meter Including All Accessories, Software & Mounting Arrangement 4 Sensor Data Acquisition Equipment Including Data Loggers, Modems, Etc. With All Accessories 5 Vsat Communication Setup Including All Hardware, Software, Fixed & Recurring Fees, Etc. 6 Terrestrial Communication Setup (Gsm/Gprs Modem / Multi-Sim Internet Generator, Etc.) Including All Hardware, Software, Fixed & Recurring Fees 7 Prefabricated Enclosure With Internal & External Lighting, Fire Detection & Suppression System, Etc. And Associated Civil Works 8 Hybrid Spv Based Power Supply System With Li-Ion (Lifepo4) Batteries And All Accessories Including Cables, Distribution Arrangement Including Protection, Control & Monitoring Systems 9 Command & Control Centre 10 Vsat Communication Setup Including All Hardware, Software, Fixed & Recurring Fees, Etc 11 Terrestrial Communication Setup (Gsm/Gprs Modem / Multi-Sim Internet Generator, Etc.) Including All Hardware, Software, Fixed & Recurring Fees 12 Prefabricated Enclosure (Porta Cabin) Along With Internal & External Lighting, Fire Detection & Suppression System, Air Conditioning, Access Control System, Etc. And Associated Civil Works 13 Hybrid Spv Uninterrupted Power Supply System With Vrla Batteries (05 Days Backup) And Associated Cables & Cabling Accessories, Distribution Arrangement Including Protection, Control & Monitoring Systems.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu and Kashmir View Result →
21.
Housing Urban and Rular Development #11047139 Technical Bid
Tender For 1. Supply, Installation, Testing And Commissioning Of Walk In Cold Room Made Of 100 Mm Puf Panels With Ppgi For Internal And External Surface For Cold Room Along With Other Accessories Having 01 No. Of The 34 To 40(W) X 72 To 80(H) Flush Door 100Mm Ppgi Finish Both Sides. The Job Includes Civil Works As Per Necessity And Other Allied Works At Site. The Puf Panels Shall Be Of Make Sintex /Lloyd/Jindal. Material To Be Stored : Blood Samples Ambient Temperature: =450C Room Temperature : 20C Pull Down Time : =20 Hrs Room Size (External) : 10×8×10 Cold Room Structure: 1) Room Size (External) : 10×8×10 2) Door Size: 34 To 40(W) X 72 To 80(H) 3) Door Type: 100Mm Ppgi Both Side Flush Type Door, Plastic Curtains On The Door Way, Flush Type Door With Kick Plate At Bottom And Fitted With Door Closer, Examination Window (View Port), Seal Closer Mechanism. Heavy Duty Lock - Lockable With 100% Fail-Safe Provision For Opening From Inside. 4) Wall Panels: 100 Mm Thick Puf Wall Panels With Density Of 40±2 Kg/M3 For Cold Room With Cam Lock For Puf Panels Inter Locking. 5) Panel Finish: Ppgi For Both Sides Of Panel (Corrosion And Moisture Resistant) 6) Flooring: Aluminum Checker Plate 10 Guage Or 3Mm Thick With Over Insulated Base Refrigeration System: Supply, Installation, Testing And Commissioning Of 01 No. Refrigeration Units (One Main And One Standby Cold Room Machine) Of Minimum Of 24000 Btu/Hr Capacity Each Along With Evaporator Make: Bluestar, Voltas, Carrier. Job Also Includes Supply And Installation Of Other Accessories Such As Expansion Valve, Control Panels, U Flashings, Inner Flashings And Flat Flashings And Sealant Etc. As Per Site Requirement. Supply And Installation Of Ms Frame In Position And Applying A Priming Coat Of Approved Steel Primer For Odu Unit And For Isolator Mcb With Box With Electrical Wire With Copper Piping, Drain Work And Other Civil Work As Per Site. 1) Temperature Range: +1°C To +6°C 2) Refrigerant: Eco-Friendly As Per Norms/Design 3) System: Air-Cooled 4) Compressor: Reciprocating/Rotary 5) Cooling Capacity: Min. 24000Btu/Hr @-4 Evap. Temp. And Condensing Temp Of 540C 6) Number Of Cdu: 01 No. 7) Evaporator: Min. 24000Btu/Hr 8) No. Of Evaporator: 01 No With 03 Nos Of Fans: 9) Supply: Three Phase 10) Electric Load: 2.8Kw/Hr (Approx.) 11) Automatic Voltage Stabilizer: 7.5 Kva 3 Phase Along With Supply Installation Testing And Commissioning Of Required Assorted Size Cables As Per Site Requirements For Commissioning And Running Of Whole Installed System. Electrification: Proper Electrification Of Cold Storage Room By Way Of Providing And Installation Of Power Points, Lighting, Fans Along With Electric Cables Of Assorted Sizes As Per Site Requirement. Complete Job Includes Tapping Of Power Supply From The Main Panel With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. Complete Job With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. , Supply And Fixing Of 04 Nos. Ss-304 Adjustable Rack Of Size 4-0X 8-0X1-0 With Sheet Thickness 1.0/0.8 Mm In Position Along With Required Allied Works For Medicine Storage Size As Per Medical Standards. , Chemical Earthing Of Db By Way Of Excavation Of 01 No. Pit Of Proper Size Upto A Depth Of 03M For Providing And Laying Of 03 Meter Copper Electrode 01 Nos. In Hard And Soft Soil Followed By Filling Of Required Quantity Of Earthing Chemical. Job Includes Filling Of Pit With Excavated Soil And Fitment Of Copper Electrode With Copper Strip From Electrode To Machine. Complete Job With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. , Electrical Work- Providing And Fitting Of 02 Nos. Tpn, Distribution Board, Aluminum (Armoured) 25Sqmmx4 Core - 30 Mtrs, 6 Sq.Mm Copper Cable- 60 Mtrs. , Miscellaneous Work- Job Includes Minor Civil Works And Repairs To The Wall Plaster Wherever Necessary, Alarm System For Trapped Person, Loading, All Type Of Miscellaneous Framework, Unloading, Freight, Lock System, Etc , Supply Installation Testing And Commissioning Of 2.0 Tr Split Air Conditioners (Hot And Cold) With All Accessories (Along With Outdoor Stand) And Ambient Upper Temperature Range Of = 52 Degree Celsius For Cooling With Maximum Cooling Capacity = 6500 W And For Heating Ambient Lower Temperature Range = 0 Degree Celsius With Maximum Heating Capacity = 6000 W Having Air Flow Rate =590 Cfm With Minimum 3 Star And Of Reputed Make I.E., O-General, Mitsubishi, Daikin, Hitachi, Bluestar Along With Allied Accessories I.E. Minimum Of 10 Of Refrigerant Pipes And Communication Cable. Complete Job As Per Site Requirement And Instructions Of Engineer-In-Charge And Also Includes Cost Of Materials, Labour Charges, Transportation Charges And All Other Charges. , Supply, Installation, Testing And Commissioning Of 5Kva Copper Wound Automatic Wall Mounted Voltage Stabilizer Input Voltage Range Of 90-300V & Of Superior Quality Isi Mark For Acs. Make: Microtek/Aulten/Servokon/Electricfield , Providing And Fitting Of Spn Of 40 Annual Periodical Maintenance Of Reputed Make I.E. Havells, L&T With Cover (Complete With Fittings) For 2.0 Tr Capacity Acs To Be Installed. , Providing And Fitting Of Extra Copper Pipe With Insulation. , Providing And Laying (Using Conduits And Wire Fasteners / Cable Clips) ) Of 10 Sq Mm 4 Core Multistrand Flexible Isi Marked, Frls Pvc Insulated Copper Conductor Cable And Of Standard Make I.E. Havells, Polycab, Finolex, Anchor Only For The Purpose Of Connecting Stabilizers To The Electrical Panel. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Also Includes Cost Of Materials (Including Clamps, Bends/Elbows, Tee-Bends, Thimbles Etc.), Labour Charges, Transportation Charges And All Other Charges And Taxes. , Providing And Laying Of (Using Conduits And Wire Fasteners / Cable Clips/Conduit Fasteners) 4 Sq Mm Isi Marked, Frls Pvc Insulated Copper Conductor Cable Of Standard Make I.E. Havells, Polycab, Finolex, Anchor Only For The Purpose Of Connecting Air Conditioning Units (Outer & Inner) To The Stabilizer. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Also Includes Cost Of Materials (Including Clamps, Bends/Elbows, Tee-Bends, Thimbles Etc.), Labour Charges, Transportation Charges And All Other Charges And Taxes. , Providing And Laying Of Pvc Drain Pipes Of Assorted Sizes Viz. ¾, Etc. To Collect And Transport The Drained Water From The Ac Unit To A Designated Location, Considering The Specific Requirements Of The Site. The Pvc Pipes Will Be Installed With Appropriate Size Bends And Clamps To Ensure Proper Alignment And Secure Connections. Job Also Includes Miscellaneous Works Civil Works Like Wall Opening To Pass Ducts & Pipes, Plastering & Refinishing Of The Same To The Original Finish As Per The Site Requirements. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Includes Cost Of Materials (Including Clamps, Bends/Elbows, Nipples, Tee-Bends, Etc.), Labour Charges, Transportation Charges And All Other Charges And Tax. , Providing, Fitting And Testing Of Air Curtains At The Main Entrance Of Blood Bank At Gmch Jammu The Air Curtain Should Be In A Metal Casing, Strong, Fire Resistant, Simple Installation And Easy Cleaning. They Should Have Double Air Way Deflectors Design Obtaining An Even Air Stream So That It Creates An Invisible Air Barrier Over The Doorway That Prevents The Inner Cool/Warm Air From Going Outside And Also Prevents Insects , Dust Etc From Entering Inside The Ward. All The Air Curtains Have To Be Fixed On The 8 Mm Ply Board Fitted And Hung By Sides . The Specifications Of Air Curtain Should Be: Material Of Cabin-- Cold Rolled Mild Steel 1. Base Plate- 16 Swg 2.Body- 18 Swg 3.Grilles- 20 Swg 4. Blower Housing- 20 Swg 5. Length- 6.00 Of Curtain Interior Finish- Anti Rust Treatment With Primer Paint, Exterior Finish- Ht Paint/Stove Painting (Powder Coating), Fans And Motors- The Multiple Forward Curved Centrifugal Type Aluminum Fan Wheels Statically And Dynamically Balanced Driven By Extended Motor Shaft. The Job Also Includes Providing And Fitting Of 4Mm Sq Wire Of Suitable Length To Be Connected To The Main Power Supplies Of Each Unit, Spns- 1 Nos With Covers, Baton, Pvc Clamps And Gutties Etc As Per Site Requirement Complete Job Includes Cost Of Material, Transportation, Labour Charges And All Types Of Taxes. , Repair And Cleaning Of Ducts Of Air Conditioning At Various Locations Of Blood Bank Of Gmch Jammu By Way Of Removal Of Vent Grilles And Diffusers For Manual Cleaning Using Industrial-Grade Hepa-Filtered Vacuums, Soft-Bristle Brushes, And Compressed Air Tools To Eliminate Dust, Debris, And Other Particulate Buildup From The Visible Portions Of The Duct Openings And Repair To All The Damaged Vents As Per Site Requirement So That The Air Flow Reaches The Last End Duct. All Debris Collected During The Cleaning Will Be Properly Contained And Disposed Of Offsite. After Cleaning, All Vents And Will Be Securely Reinstalled And Airflow Tested To Confirm Proper Operation. A Visual Inspection And Photographic Documentation Of Cleaned Vents Will Be Included In The Final Job Report. The Job Includes Replacement Of Damaged Power Coated Aluminium Extruded Grill. Complete Job Includes Cost Of Material, Consumables,Labour And All Types Of Taxes Etc , Providing And Fitting Of 4K Hdmi Cable 5 Meter , 55 Led Tv 4K For 24X7 Operations With Uhd Dimming And Auto Motion Plus Make: Samsung/Sony/Sansui , Supply & Installation Of 5 Mp Ir Fixed Network Dome/Bullet Camera- Suitable For Outdoor Operation With Following Specifications Along With Accessories Required For Fitting. 30 Meter Ir, 1/2.7 Progressive Scan Cmos Color: 0.0125 Lux @ (F2.0, Agc On) 0 Lux With Ir, Resolution: 2592 × 1944 Or Better ,Wdr Should Be 120Db Or Higher, 3.6Mm,Mic And Speaker Inbuilt , Camera Shall Have Ip67 Ingress Protection And Ce, Fcc, Ul, Rohs,Cmmi-5 , ,Weee Certifications Make: Hi Focus/Matrix/Prama , Supply & Installation Of 16Channel 2 Sata Network Video Recorder-For Encoding And Processing The Video Data At The Camera ,Then Streaming To The Nvr Recorder For Storage And Remote Viewing With Following Specifications And Features. Nvr Shall Support Up To 12 Mp Or Higher,Nvr Shall Support 4K (3840 × 2160) ,Nvr Shall Support 16-Ch Playback,Tcp/Ip, Dhcp, Dns, Ddns, Ntp, Sadp, Smtp, Nfs, Iscsi, Upnp™, Https ,Nvr Shall Support 02 Sata Interface. Nvr Shall Support Up To 16 Tb Capacity For Each Hdd,1 Rj-45 10/100/1000 Mbps, Nvr Shall Support Sh.265,H.265+,H.265,H.264 Video Compression, Onvif Compatible,Shall Have Ce, Fcc, Ul, Bis,Rohs,Cmmi-5 ,Weee Certifications Make: Hi Focus/Matrix/Prama , 4 Tb Av Hdd Make: Seagate/Wd/Toshiba , Providing & Fitting Of Rack 4U With Glass Door And Lock Fully Loaded Conforms To Din 41494 & Iec 297 , Iso 9001:2015 Standards Make: Comrax/ President/Apc , Supply & Installation Of 8 Port Giga Poe Switch, With 8*10/100/1000Mbps Ports1-8 + 2*10/100/1000 Ports 9-10 Poe Ports, Full Duplex ; 1000 Mbps, ,Poe Power Budget: 96W,Standards: Ieee 802.3, Ieee 802.3U, Ieee 802.3Ab Ieee 802.3Xl Ieee, Packet Forwarding Rate: 14.88Mbps, 8K Mac Address Table, Packet Buffer Size 192Kb Make: Hi Focus/Digisol/D-Link/Netgear , Providing & Fitting Of Conduit 25Mm Along With Clamps Etc. , Providing/Supply, Installation, Testing & Commissioning Of Cat-6 Outdoor Cable Cat6 4-Pair U/Utp Outdoor Double-Jacketed Cable With Frequency Range: 1-250 Mhz, 23Awg ( 0.55Mm) Solid Bare Copper Conductor, High-Density Polyethylene(Hpde) Color Coded As Per Ansi/Tia-568 2-D Insulation,Cable Core: 4 Twisted Ppair Held In Place By Hdpe Cross-Web Separator,Water Resistant: Jacket Only,Inner Jacket: Lszh Grey, Outer Diameter:7.0Mm Nominal,Outer Jacket: Uv Resistant Hdpe For Outdoor Use, Black Make: Amp/ Honeywell/Commscope/Comrax , Providing & Laying Of Power Cable With 3 Core ,2.5 Sq.Mm ,Copper Make: Finolex/ Havell/ , 1Kva Online Ups With 60 Minutes Smf Battery Backup With Rack Make: Elnova/Fuji/Apc , Providing And Fitting Of Rj 45 Jacks Which Includes Crimping At Both The Ends Of The Cable , Integration, Testing &Commissioning All The Equipments And System For Proper Functioning
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
22.
Housing Urban and Rular Development #10911425 Price Bid
Tender for 2.28.1Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M , 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , 2.25(A)Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , 1.1.2Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 2.35.3.1Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 4.17Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 4.1.8Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.4Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 5.33.1.1Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level - Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.22A6steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases For Columns, Etc. For Mass Concrete , 5.9.6Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.21Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 5.9.20Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform With Water Proof Ply 12 Mm Thick , 5.9.7Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Stairs, (Excluding Landings) Except Spiral-Staircases , 6.4.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 6.13.2Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , 6.15Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry , 13.2.215 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Fine Sand) , 13.1.212 Mm Cement Plaster: 1:6 (1 Cement: 6 Fine Sand) , 13.16.16 Mm Cement Plaster Of Mix : 1:3 (1 Cement : 3 Fine Sand) , 10.15.1Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular/ L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , 9.20.1Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , 10.11.1Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings,Glass Panes Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , 10.3Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes , 9.48Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding , 9.51.2Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With Second Class Teak Wood Beading 62X19 Mm , 9.100.1Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125 Mm , 9.97.1Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :300X10 Mm , 9.96.1Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300X16 Mm , 9.103.1Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , 9.101.1Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. Single Rubber Stopper , 9.109Providing And Fixing Ptmt Door Catcher Of Length 72 Mm And Dia. Of 42 Mm With Suitable Washers Weighing Not Less Than 33 Gms , 8.31Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 11.47.2Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , 11.38Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , 11.56.1Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing , Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. 11.56.1 Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent , 13.8Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.41.1Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , 13.46.1Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sq M) , 13.62.1Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 10.26.1Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : (A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. (B) Second Layer Of Slurry Of Cement @ 0.242 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. (The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 5.3Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 22.1.Iproviding And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : 22.7.1 With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , 18.7.1Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.15 Mm Dia , 18.7.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.20 Mm Dia , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.25 Mm Dia , 18.7.4Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.32 Mm Dia , 18.7.5Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.40 Mm Dia , 18.7.6Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.50 Mm Dia , 18.9.7Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge , 18.51.1Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , 18.84.1Providing & Fixing Chrome Plated Brass Battery Based Infrared Sensor Operated Pillar Cock, Having Foam Flow Technology. , 18.53.1Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 , 18.10.1Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 15 Mm Dia , 18.10.3Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 25 Mm Dia , 18.10.6Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 50 Mm Dia , 18.18.1Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 15 Mm Normal Bore , 18.18.2Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 20 Mm Normal Bore , 18.17.1Aproviding And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Noramal Bore , 18.17.1Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 25 Mm Noramal Bore , 18.19.5.1Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : , 18.48Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 17.3.1Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 17.16Aproviding And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge , 17.7.8Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 17.10.1Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board - 510X1040 Mm Bowl Depth 250 Mm , 17.69.2Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour. Waste Coupling 38 Mm Dia Of 83 Mm Length And 77 Mm Breadth, Weighing Not Less Than 60 Gms , 17.28.2.1Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia , 17.22Aproviding And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , 17.22Bproviding And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. , 17.35.1.3Providing And Fixing Soil , Waste And Vent Pipes: Hubless Centrifugally Cast (Spun) Iron Pipes Epoxy Coated Inside & Outside Is:15905 100 Mm Dia , 17.35.2.3Providing And Fixing Soil , Waste And Vent Pipes: Hubless Centrifugally Cast (Spun) Iron Pipes Epoxy Coated Inside & Outside Is:15905 75 Mm Dia , 18.65Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. , 17.37.1Providing And Fixing M.S Holder-Bat Clamps Of Approved Design To Sand Cast Iron/ Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Including Cost Of Cutting Holes And Making Good The Walls Etc. 100 Mm Dia , 17.37.2Providing And Fixing M.S Holder-Bat Clamps Of Approved Design To Sand Cast Iron/ Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Including Cost Of Cutting Holes And Making Good The Walls Etc. 75 Mm Dia , 17.38.1.1Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 100 Mm Dia , 17.38.2.1Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 75 Mm Dia , 17.39.1.1Providing And Fixing Plain Bend Of Required Degree Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.39.2.1Providing And Fixing Plain Bend Of Required Degree Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.60.1.2Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : Sand Cast Iron S&S As Per Is: 1729 100 Mm Inlet And 100 Mm Outlet , 17.60.2.2Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : Sand Cast Iron S&S As Per Is: 1729 100 Mm Inlet And 75 Mm Outlet , 17.32.1Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing , 17.56.1.1Providing And Fixing Terminal Guard Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.56.2.1Providing And Fixing Terminal Guard Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.57.1.1Providing And Fixing Collar : Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.57.2.1Providing And Fixing Collar : Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.71Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms , 17.72Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215Mm Long, 200Mm Nos. Wide With A Minimum Distances Of 37Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colours Weighing Not Less Than 80 Gms , 17.73.2Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. (For Bath) , 17.74Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms. , 18.22.1Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 100 Mm Diameter , 18.77Cutting Holes Up To 15X15 Cm In Reinforced Cement Concrete Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Finishing Complete So As To Make It Leak Proof. , 12.41.2Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. , 2.8.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil , 5.9.5Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.3Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.2Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.10.4Providing And Fixing Tie Bolt, Spring Coil And Plastic Cone In Wall Shuttering Complete As Per The Direction Of Engineer-In-Charge.20 Mm Dia.& 225 Mm Length , 13.7.212 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement :1:4 (1 Cement : 4 Fine Sand) , 19.32.1Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , 5.1.2Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 6.4.1Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , 16.53.1Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, Cement Concrete Blocks Shall Be Paid Separately) , 1.1.2Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , 16.92.1Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 16.69.1Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge (Length Of Finished Kerb Edging Shall Be Measured For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge) , Aor2019supply, Installation, Testing And Commissioning Of Ongrid Solar Photovoltaic Power Plant Conforming To Mnre Specifications As Amended, Consisting Of Mono/Poly Crystalline Silicon Solar Cells, Net Metering Facility, Necessary Protections, Earthing, Mounted On Aluminium/Gi Structure Of Suitable Strength With Following Components Complete As Required:- A) Solar Photovoltaic Module Of Capacity 330 Wp Or Above, Manufactured In India, Conforming To Is 14286/Iec 61215, Is/Iec 61730-Part-1, Is/Iec 61730-Part-2. Solar Photovoltaic Module Conversion Efficiency Shall Not Be Less Than 16.5%. Pv Modules Used In Solar Power Plants/ Systems Must Be Warranted For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. B) Power Conditioning Unit (Pcu) Of 350-800 V Dc Input Voltage Range And 400 V Ac, Three Phase, 4 Wire, 50Hz +/- 2.5 Hz, Output Voltage Suitable To Generate Ac Power With Efficiency Not Less Than 97%, Total Harmonic Distortion Less Than 3% And Suitable For Ambient Temperature From 0 To 50 Degree C. The Pcu Shall Adjust The Voltage And Frequency Level To Suit The Grid Voltage Frequency. , 2-2 Miscconcrete With Cement, Coarse Sand And 40Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 4-2-4 Mordgravel/Soil Aggregate Base/Subbase Nominal Maximum Size Grading 80 Mm (Table 2.3 Of Irc Sp 77-2008) Construction Of Gravel/ Soil Aggregate Subbase/ Base By Providing Well Graded Material Of Nominal Maximum Size Grading 80 Mm As Per Table 2.3 Of Irc Sp 772008, Spreading In Uniform Layers With Tractor Mount Appropriate Grading Arrangements On Prepared Surface, Mixing By Mix In Place Method At Omc With Tractor Mount Appropriate Rotavator Attachment And Compaction With Three Wheel 80100 Kn Static Roller Capacity To Achieve The Desired Density Complete As Per Specifications Contained In Para 2.2, 3.6 And 3.7 Of Irc Sp 77-2008. , 4-7-3A Mordwater Bound Macadam Sub-Base/Base Wbm Grading 3 Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screening To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 3 As Per Technical Specification Clause 405. By Manual Means , 2-3 Misccement Concrete (Pcc M-30) Pavement:- Construction Of Un-Reinforced, Cement Concrete Pavement, Thickness As Per Design, Over A Prepeared Sub Base With 43 Grade Cement Or Any Other Type Plain Cement Concrete Grade M 30, Coarse And Fine Aggregates Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Then 0.2 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of Wedges, Steel Plates Including Levelling The Formwork, As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, And Plate Vibrators, Finished In Continuous Operation And Curing Of Concrete Slabs For 14 Days, Using Curing Compound Where Specified And Water Finishing To Lines And Grade As Per Drawings And Technical Specifications. , 1.10.3Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , .1.12Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loopearthing As Required , 1.14.1Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire (For Circuit Wiring & Light Plug Wiring) , 1.14.2Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 6 Sq. Mm + 1 X 6 Sq. Mm (For Single Phase Db. From Sub Panel To Db) , 1.14.4Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required4 X 6 Sq. Mm + 2 X 6 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.9Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 10 Sq. Mm + 2 X 6 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.10Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.11Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.24.1Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 5/6 A Switch , 1.24.4Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 3 Pin 5/6 A Socket Outlet , 1.24.3Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 15/16 A Switch , 1.24.5Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 6 Pin 15/16 A Socket Outlet , .1.31Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required. , .1.32Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , .2.19Supplying And Fixing 20 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. , .1.25Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , .1.33Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connections Etc. As Required. , .1.34Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required , 1.27.1Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.1 Or 2 Module (75Mmx75mm) , 1.24.7Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Tv Antenna Socket Outle , 1.24.8Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. Reqired Bell Push , 1.21.1Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 1.21.2Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25 Mm , 1.53.1Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 1 Run Of Cable , .1.41Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube/Lamp Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , 1.50.1Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , .1.51Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes. , .10.18Providing And Fixing Circular/ Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron/ M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. , .19.1Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min , 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , 2.10.1Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , .2.11Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , 2.3.2Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 8 Way Double Door , 2.4.3Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 8 Way (4 + 24), Double Door , 2.13.1Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A , 2.13.2Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A , 2.14.1Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 A , 2.14.2Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 A , 2.14.3Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63A , 7.1.2Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required.Above 35 Sq. Mm And Upto 95 Sq. Mm , 9.1.13Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 X 95 Sq. Mm (38Mm) , 4.6.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.7.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.125 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.8.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.9.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.10.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , Nsithe Maximum Allowable Temperature For The Bus Bar To Be Restricted To 90 Deg C. The Temperature Rise Should Be Restricted To 45 Deg C Above Ambient Temperature.Complete Panel As Above And Complete , Gemsproviding And Supplying Of Led Batten 20 Watts 1150 Mm , Gemsproviding And Supplying Of 9W Led Bulb With Battery-Is:16102, Warranty For Free Replacement 1 Year , Gemsproviding And Supplying Of 12W Warm White Ceramic Circular Led Surface Ceiling Light , Gemsproviding And Supplying Of 1200Mm Bldc Motor Electric Ceiling Fan , Gemsproviding And Supplying Of Aluminium Wall Fan 2 Year Warranty , Gemsproviding And Supplying Of Exhaust Fan 300 Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
23.
Public Administrative Department #10803650 Price Bid
Providing Necessary Electrical Work Of Hospital And Opds In F Ward (2025-26)-Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.3 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. Point wiring for independent plug in PVC trunking casing-capping) with 1.5 mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block wooden board with 3 years warranty. Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. Supplying and erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips completewith 3 years warranty. Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. Supplying and erecting Electronic type cordless call bell erected on T.W.board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. 2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG#PW/CW Supplying and erecting PVC Surface modular switch box with double mounting plate for module duly erected. Supplying and erecting PVC Surface modular switch box with double mounting and front plate for 8 module complete duly connected. Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete Supplying and installing cat- cable suitable for networking as per specification no. WG-COC/NC Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord and grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying including excavation of suitable width and depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing and recording the results as per specification no. EA-EP Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. Supplying, erecting and marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Supplying, erecting and marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity 10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erectedat the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP#WCR/WC Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV ge rmicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail and filter change indication system .(for TDS more than 200) Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut and bolts routed in wall Supplying and erecting minimum Three and above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 1.5 KW/2HP suitable for erection on open well, pump having delivery head from 29 to 7 m and discharge from 30 to 600 litres. . per minute and pipe ofSuction 50 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP Supplying and erecting D.O.L Starter suitable for 250 V, Single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 H.P Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground and Over head tank operation only. Supplying, installing, testing and commissioning split type variable speed inverter technology with minimum 3 to convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation and temperature display on indoorunit, noise level maximum 50dBA at position as per specification no. APAC/ Supplying and erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with 54 protection Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
24.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
25.
Public Administrative Department #10768140 Price Bid
E -Tender For Supply Installation, Testing And Commissioning With Five Years Comprehensive Maintenance Contract Of 40 Kwp Solar Roof Top On Grid Power System With Net Metering System At Metering System At Administrative Building Ulhasnagar Municipal E -Tender For Supply Installation, Testing And Commissioning With Five Years Comprehensive Maintenance Contract Of 40 Kwp Solar Roof Top On Grid Power System With Net Metering System At Metering System At Administrative Building Ulhasnagar Municipal , Supplying, Installing,Testing Andcommissioning Of 40 Kwp Capacity On-Grid Solar Power Pack With Gi Mounting Structure And Inter Connecting Wires / Cables Without Battery Bank Spv Modules Of 40 Kwp, Solar Power Conditioning Unit Of Min. 40Kwp Capacity Completemake:-Solar Panel:Tata/Spark/Vikram/Shell Invetors:-K Solar /Polycab/Db/Sofarfabrication:- Gi Structures As Per Umcspecification And Guidlines , Supplying, Installtion & Marking Of Surge Arrestor/ Surge Protection Device At The Main Distribution Board After The Incoming Breaker Of Type 1+2 Conforming To Iec 61643- Ii Tested For Imax 100 Ka For Single Phase & Neutral Make:- As Per Specification , Providing Earthing With Copper Earth Plate Size 30 X 30 X 0.315 Cm Complete With All Materials, Testing & Recording The Results Make:-As Per Ie Specification , Supplying And Erecting Gi Strip Of Required Sizeused For Earthing On Wall And/Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint In An Approved Manner With Joints Required. Make:-As Per Specification , Supplying, Erecting & Terminating Pvc Armoured Cable 3 Core 50 Sq Mm Aluminium Conductor With Continuous 5.48 Sq Mm (12 Swg) G.I. Earth Wire Complete Erected With Glands & Lugs,Make:-Polyacb/Vishal Cables/Finolex , Supplying And Erecting Of Solar Net Meterring Which Can Import And Export The Electricity ,Net Metering Procedure With Msedcl Sanctioning The Solar Power Plant Make:-Rishab/L&T/Havels
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
26.
Public Administrative Department #10768134 Price Bid
E -Tender For Supply Installation, Testing And Commissioning With Five Years Comprehensive Maintenance Contract Of 40 Kwp Solar Roof Top On Grid Power System With Net Metering System At Stp Plant Near Shanti Nagar Ulhasnagar-3 E -Tender For Supply Installation, Testing And Commissioning With Five Years Comprehensive Maintenance Contract Of 40 Kwp Solar Roof Top On Grid Power System With Net Metering System At Stp Plant Near Shanti Nagar Ulhasnagar-3 , Supplying, Installing, Testing Andcommissioning Of 40 Kwp Capacity On-Grid Solar Power Pack With Gi Mounting Structure And Inter Connecting Wires / Cables Without Battery Bank Spv Modules Of 40Kwp, Solar Power Conditioning Unit Of Min. 40Kwp Capacity Completemake:-Solar Panel:Tata / Spark / Vikram / Shell Invetors:-K Solar / Polycab / Db / Sofarfabrication:- Gi Structures As Per Umcspecification And Guidlines , Supplying, Installtion & Marking Of Surge Arrestor / Surge Protection Device At The Main Distribution Board After The Incoming Breaker Of Type 1+2 Conforming To Iec 61643- Ii Tested For Imax 100 Ka For Single Phase & Neutralmake:- As Per Specification , Supplying And Erecting Gi Strip Of Required Sizeused For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint In An Approved Manner With Joints Required. Make:-As Per Specification , Supplying, Erecting & Terminating Pvc Armoured Cable 4 Core 16 Sq Mm Aluminium Conductor With Continuous 5.48 Sq Mm ( 12 Swg ) G.I. Earth Wire Complete Make:-Polyacb / Vishal Cables / Finolex , Supplying And Erecting Of Solar Net Meterring Which Can Import And Export The Electricity , Net Metering Procedure With Msedcl Sanctioning The Solar Power Plantmake:-Rishab / L&T / Havels
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
27.
Public Administrative Department #10730816 Price Bid
Proposed Furniture Work At Kusumagraj Smarak In P.No.12 Nashik West Division.-1 COLLECTION counter Providing & fixing COLLECTION counter as per design of 0.9 m width & 1.2 in height with drawers above in 19mm thk. waterproof ply for frames, sliders & drawer facia,6mm thk. plywood for back & drawer bottoms with 12mm plywood for drawers, drawer side with bte lipping to all exposed edges of plywood including 1.mm thk. Laminate on top & 1mm thk laminate on sides & front of drawer facia & sliding shutters with necessary tower bolts castors handles, locks,etc.complete.with oil paint to all exposed surfaces of ply & lipping. Additional item Spec. no. as directed by Spec.No.: RA 22-23 A GROUND FLOOR 2 Providing and fixing vertical/roller blindes for window as approved by engineer in charge and architect GEM ID - 5116877-93262266948 Spec.No.: QUOTATION ATTACHED A GROUND FLOOR 3 GODREJ -ENTERPRIES TABLE 1200X600 X750 Enterprise 1200 Table without CPU Hanger size shall be 1200 Width mm x 600 Depth mm x 728 Height mm . Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 & MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) . Spec.No.: AS PER QUTATION A GROUND FLOOR 4 GODREJ MAKE REVOVING CHAIR THRILL FULL BACK 1. SEAT/BACK ASSEMBLY: The back is made up of 1.2 ±0.1cm. thick hot-pressed plywood & seat is made up of 1.5 ±0.1cm. thick hot-pressed plywood measured and upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam is designed with contoured foam lumbar support. The seat has extra thick foam on front edge to give comfort to popliteal area .The Recron filling done in seat & back ( Executive chairs only) for extra fluffiness and comfort in chair. The chair seat & back size are *HIGH BACK SIZE 51.5 cm. (W) x 82.0 cm. (H) *FULL BACK SIZE 51.5 cm. (W) x 69.0 cm. (H) *SEAT SIZE 53.5 cm. (W) x 51.0 cm. (D) 2. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam is moulded with density = 45±2 kg/m3 and hardness load 14 ± 2 kgf as per IS:7888 for 25% compression. 3. ARMRESTS (THRILL PLUS CHAIR) : The adjustable armrest is designed with the following features · Up-Down adjustment- 6 steps (7.2 ± 0.5cm range) · Armrest top is mounted on Armrest structure made of glass filled Nylon. · Armrest Top is PU moulded over glass filled Nylon insert. 4. CENTER TILT SYNCHRO MECHANISM WITH MULTI LOCK : The mechanism is designed with the following features: · 360° revolving type. · 3 position locking with anti shock mechanism. · Tilt tension adjustment 5. PNEUMATIC HEIGHT ADJUSTMENT : The pneumatic height adjustment has an adjustment stroke of 9.5 ± 0.3 cm 6. PEDESTAL ASSEMBLY ( THRILL PLUS) : The pedestal is injection moulded in black glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal is 66.1 ±0.5cm. pitch-center dia. (76.1 ±1.0cm with castors). 7. TWIN WHEEL CASTORS : The twin wheel castors are injection moulded in Black Nylon. WIDTH (W): 76.1 CM. DEPTH (D): 76.1 CM. HEIGHT (H): 113.5-123.5 CM. SEAT HEIGHT (SH): 46.0-56.0 CM. Spec.No.: AS PER QUTATION A GROUND FLOOR 5 GODREJ MAKE RELFEX CHAIRS WITH STACKEBALE TYPE 4 METAL LEG . SEAT / BACK ASSEMBLY : The Seat is injection moulded in glass filled Polypropylene compound which is upholstered with fabric upholstery covers and moulded Polyurethane foam. The Back is injection moulded in glass filled Polypropylene compound which is upholstered with Mesh fabric (Refer colour chart for seat & Back upholstery in product catalog). * SEAT SIZE : 50.0cm. (W) x 48.0 cm. (D) * BACK SIZE : 53.0 cm. (W) x 39.0cm. (H) 2. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45±2 kg/m³ and hardness 16±2 kgf as per IS:7888 for 25% compression. 3. M.S. POWDER COATED FRAMES FOR 4 LEG CHAIRS :The powder coated ( DFT50±10 microns) welded tubular main frame is made from Ø 2.54 ± 0.03 cm x 0.2 ± 0.016 cm andØ1.6±0.3mm x 0.16 ± 0.0128cm M.S. E.R.W tube. The Ø1.9 ±0.3mm x 0.12 ±0.0096 cm M.S.E.R.W. tube used as connecting member between LH & RH frames. Desk let support frame is made from Ø 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm and welded to mainframe. Spec.No.: AS PER QUTATION A GROUND FLOOR 6 GODREJ MAKE GAIN 8 FT HIGHT GLASS DOOR BOOK RACK- 2325 H x 900 W x 450 D GAIN PRO STORAGE (BOOK RACK) 2325 H x 900 W x 450 D EACH UNIT SIZE Construction & Material - Aesthetically appealing completely knock down construction. The add-on units are stack widthwise to form arow of storage.(Note- Single Main unit should not be offered. Minimum 1Main + 1Addon to be offered)Legs fitted with screw type leveler.Made from combination of Top panel(0.5mm CRCA), side panel(0.5mm CRCA), Bottom panel(0.5mm CRCA for 450W/600W and 0.8mm CRCA for 900W/1200W), Back panel(0.5mm CRCA), Top Bottom stiffener(1.2mm CRCA) and End Cover(0.5mm CRCA). ** - CRCA D Grade as per IS-513Shelving - It is a 12 bend panel made of 0.7mm Thick CRCA (D Grade, IS-513) Each shelf has max Load Capacity of - 4 Nos. of fixed shelves for 1950(H) A4 size Box file (85Wx340Hx285D) can be stored vertically on all loading levels (Refer Sheet 4 of 17) Number of files that can be stored in one shelf is as follows: Finish - Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10 micron). Construction & Material - Made from 0.6mm Thick CRCA (D Grade, IS-513) Soft closing Hinge Handle - Asthetically appealing handle made of Aluminum Cam Lock -3 Way locking provision. Click action mechanism. #NAME? positions. Zinc alloy die cast housing. Finish - Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10 micron).Material to be supplied by certified ISO 50001:2018, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, ISO 13485:2016, AIOTA member. Item should have at least one of the GRIHA/GREENGAURD/GREENPRO/ GREEN ASSURANCE Certifications adhering to standard environmental practices. Valid test certificate should be available for the item under consideration. Also, OEM must have dedicated toll free service number. Spec.No.: AS PER QUTAION A GROUND FLOOR 7 UPBEAT Discussion Table without wire manager-Size-900 Dia.750H MM Upbeat is a Complete office Furniture setup solution, designed to cater to the various settings in an office space.19mm thick both sided laminated MDF top Metal leg with epoxy powder coating Spec.No.: AS PER QUTATION A GROUND FLOOR 8 Excavation for foundation in earth, soil of all types, sand,gravel and soft murum, including removing the excavatedmaterial up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering,preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc.complete. (Lift upto 1.5 m.) By Mechanical Means Spec.No.: Bd.A.1 PageNo. 259 I.NO 21.0 2 A GROUND FLOOR 9 Excavation for foundation in hard murum includingremoving the excavated material upto distance of 50metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming,watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No.: Bd.A.2 PageNo.269 I NO 21.0 6 A GROUND FLOOR 10 Filling in plinth and floors with Contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec.No.: Bd.A.11 Page 253 21.37 A GROUND FLOOR 11 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Spec.No.: Bd.A. 12 PAGE 254 21.38 A GROUND FLOOR 12 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.E.4 Page No. 289 and B-7, Page No.38 I.NO.24.08 A GROUND FLOOR 13 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.6 Page No. 300 and B.7, Page No.38 I.NO.25.50 A GROUND FLOOR 14 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering,ormwork, cover blocks,laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.8 Page No. 302 and B.7, Page No.38 I.NO.25.70 A GROUND FLOOR 15 Providing and laying Cast in situ/Ready Mixcement concrete M20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.9 Page No. 303 and B.7, Page No.38 I.NO.26.05 A GROUND FLOOR 16 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd. F. 12 Page No. 304 and B -7, Pg 38 I.NO.26.23 A GROUND FLOOR 17 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps,footings, foundations, slabs, beams columns, canopies,staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec.No.: Bd.F.17, Page No.306 I.NO.26 0.33 A GROUND FLOOR 18 Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Spec.No.: As director by engineer in c harge and BDG- 2 and 5 I.NO.27.12 A GROUND FLOOR 19 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Spec.No.: As director by engineer inch arge and BDG- 2 and 5 I.NO.27.13 A GROUND FLOOR 20 Providing uncoursed rubble masonry of trap / granite /quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually, striking joints on un exposed faces and watering etc.complete. Spec.No.: Bd.H.1 Page No.329 I.NO.28.0 1 A GROUND FLOOR 21 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO. 31.04 A GROUND FLOOR 22 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. Spec.No.: Bd. L.2 Page No. 368 I.NO.32 0.03 A GROUND FLOOR 23 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec.No.: Bd.L.7 Page No. 369 I.NO.32. 11 A GROUND FLOOR 24 Providing neeru finish to plastered surfaces in all positions including. Spec.No.: Bd. L.10, Page 370 I NO. 32. 15 A GROUND FLOOR 25 Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec.No.: Bd.M. 12 Page No.385 I.NO.33 0.42 A GROUND FLOOR 26 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec.No.: Bd.M. 12 Page No.385 I.NO.33 0.43 A GROUND FLOOR 27 Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Spec.No.: As directed by Engineer in c harge. I.NO.35.25 A GROUND FLOOR 28 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. Spec.No.: Bd.P.6 Page No. 414 I.NO.36. 12 A GROUND FLOOR 29 Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kgs/M2 and minimum pull out strength of 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO.38.45 A GROUND FLOOR 30 Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec.No.: As directed by Engineer inch arge. I.NO.39.02 A GROUND FLOOR 31 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating including fabricating glazing with plain / obscured glass panes 5 mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. Spec.No.: BD-T-53 Page No. 509 As dire cted by Engineer in charge I.NO.39.29 A GROUND FLOOR 32 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . Spec.No.: As directed by Engineer in c harge. i. no.39.56 A GROUND FLOOR 33 Providing and fixing 30mm thick PVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 mm MS tubes inserted horizontally inside the hollow profile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thick x 20 mm width on stiles and rails using solvent cement. The inner panel shall be laminated with 5mm thick termite proof waterproof plain /prelam PVC sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. Spec.No.: As directed by Engineer in c harge. i. no.39.82 A GROUND FLOOR 34 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec.No.: Bd.V.8 Page No. 554 I.NO.41. 400 A GROUND FLOOR 35 Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. Spec.No.: Bd.V.9 Page No. 555 I. NO.41 0.48 A GROUND FLOOR 36 Providing and fixing 15mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete. Spec.No.: Bd.V.14 Page No. 557 I.NO.41 0.52 A GROUND FLOOR 37 Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe. Spec.No.: Bd.V.23 Page No. 562 I. NO.4 1.57 A GROUND FLOOR 38 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. Spec.No.: Bd.V.30 Page No. 565 I. NO.4 1.63 A GROUND FLOOR 39 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and Spec.No.: BdV41 PAGE NO 573 I NO 42.07 0 A GROUND FLOOR 40 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 kg with lid and frame fixed in cement concrete. Spec.No.: Bd.V.43,Page No.574 I.NO.42. A GROUND FLOOR 41 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec.No.: As directed by Engineer inch arge. I.NO.42.200 A GROUND FLOOR 42 Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO.42.320 A GROUND FLOOR 43 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted by Engineer in charge I.NO.42.550 A GROUND FLOOR 44 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted byEngineer in charge I.NO.42.580 A GROUND FLOOR 45 Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted by Engineer in charge I.NO.42.600 A GROUND FLOOR 46 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. Spec.No.: BD.V 32 A page 551 and as di rected by Engineer in charge I.NO.42.670 0 A GROUND FLOOR 47 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. Spec.No.: As directed by Engineer Inch arge I.NO.42.860 A GROUND FLOOR 48 CARTING UN WANTED MATERIAL FROM SITE UP TO 5 KM Spec.No.: AS DIRECTED (LEAD CHRGES FOR 5 KM) A GROUND FLOOR 49 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. Spec.No.: As directed by Engineer inch arge. I.NO.46.090 A GROUND FLOOR PART B (ELECTRICAL) 1 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1-7-18) 2 Point wiring for ceiling fan in PVC trunking (casingcapping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1-7- 19) 3 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1- 7-20) 4 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories (PWD DSR 2022-23, 1-7-25) 5 Providing and fixing PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling (PWD DSR 2023-24, 1-2-7) 6 Providing and fixing HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling (PWD DSR 2023-24, 1-2-4) 7 Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling (PWD DSR 2023-24, 1-1-13) 8 Providing and fixing mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-1) 9 Providing and fixing mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-2) 10 Providing and fixing mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-3) 11 Providing and fixing LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete (PWD Elec 2023-24, 2-1-18). 12 Providing and fixing LED square / circular Max. W down lighter / Panel Light having pressure diecast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens,(PWD DSR 2023-24, 2-1-5) 13 Providing and fixing LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, etc complete (PWD DSR 2023-24, 2-1-5) 14 Providing and fixing Ceiling fan 230 V A.C. 50 cycles 1400 mm etc complete (PWD DSR 2023- 24, 2-9-3) 15 Providing and fixing modular type electronic step regulator for fan etc complete. (PWD DSR 2023- 24, 2-10-9) 16 Providing and fixing fan clamp of 30 x 5 mm. M. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. (PWD DSR 2023-24, 2-10- 3) 17 Providing and fixing ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected (PWD DSR 2023-24, 2-10-6) 18 Providing and fixing bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator (PWD DSR 2023-24, 2-9- 19 Providing and fixing exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials (PWD DSR 2023-24, 2-9- 13) 20 Providing, fixing and marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board (PWD DSR 2023-24, 5-3-3) 21 Providing, fixing and marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board (PWD DSR 2023-24, 5-3-9) 22 Providing, fixing single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs (PWD DSR 2023-24, 5-4-7) 23 Providing and fixing single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, (PWD DSR 2023-24, 5-4-9) 24 Providing, fixing testing and commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete (PWD DSR 2023-24, 3-2-9) 25 Providing, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete(PWD DSR 2023-24, 3-2-13) 26 Providing and fixing PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to kV (PWD DSR 2023-24, 1-3-15) 27 Providing and fixing copper pipe suitable for refrigeration system having size 12 mm complete. (PWD DSR 2023-24, 3-2-26) 28 Providing and fixing bracket for split type AC 29 Providing and fixing copper pipe suitable for refrigeration system having size 16 mm complete. (PWD DSR 2023-24, 3-2-27) 30 Providing and fixing Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm (PWD DSR 2023-24, 4-2-3) 31 Providing and fixing Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm (PWD DSR 2023-24, 4-2-4) 32 Providing and fixing rigid PVC pipe 20 mm dia.with PVC accessories for drain (PWD DSR 2023-24, 1-2-3) 33 Providing and fixing meter box with all accessories complete. 34 Providing, laying and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe (PWD DSR 2023-24, 7-1-28) 35 Providing, fixing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials and recording the results (PWD DSR 2023-24, 9-1-1) 36 Providing and fixing GI earth wire of high purity of different sizes used for earthing. (PWD DSR 2023- 24, 9-2-5)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Maharashtra View Result →
28.
Communications and Information Technology  #10712723 Price Bid
Tender For Providing Electrical Installations & Fans For Bsnl Mini Data Centre At Rail Head Building , Trikuta Nagar, Jammu.; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required: Group -C 2 Wiring For Light / Power Plug With 2X4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedsteel Conduit Alongwith 1 No 4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 3 Wiring For Light / Power Plug With 4X4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedsteel Conduit Alongwith 2 No 4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With 2X1.5Sqmm + 1X1.5Sqmm Earth Wireof Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With 2X2.5Sqmm + 1X2.5Sqmm Earth Wireof Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 6 Supplying & Drawing Following6x1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 7 Supplying And Fixing Of 20 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 8 Supplying And Fixing Of 25 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 9 Supplying And Fixing Of 32 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.: 10 Supplying And Fixing Of 5 / 6 A Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 11 Supplying And Fixing Of 15 / 16 A Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 12 Supplying And Fixing Of 3 Pin 5 / 6 A Modular Socket Outleton The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 13 Supplying And Fixing Of6 Pin 15 / 16 A Modular Socket Outleton The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 14 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 16 Supplying And Fixing Of 2 Module ( 75Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 17 Supplying And Fixing Of 4 Module ( 125Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 18 Supplying And Fixing Of 6 Module ( 200Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 19 Supplying And Fixing Of 8 Module ( 125Mmx125mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 20 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. 21 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 22 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc As Required 23 Supplying And Fixing12- Way , Double Doorsingle Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 24 Supplying And Fixing 5 A To 32 A Rating, Single Pole, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Loadin The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 25 Supplying And Fixing 5 A To 32 A Rating, Double Pole, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 26 Supplying And Fixing 5 A To 32 A Rating, Triple Pole, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 27 Supplying And Fixing 5 A To 32 A Rating, Tp&N, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 28 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 29 Supplying And Installing 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 30 Supplying And Installing 375 Mm Width X 50 Mm Depth X 2.0 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 31 Supplying And Installing 450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 32 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 33 Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) 34 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 35 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 36 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 37 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 38 Providing And Fixing 4.0 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 39 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonary Open Duct As Required. 40 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 41 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 42 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 43 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. 44 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 45 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 46 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 47 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. 48 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 49 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 50 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 51 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 52 3½ X 35 Sq. Mm ( 32Mm ) 53 3½ X 50 Sq. Mm ( 38Mm ) 54 3½ X 120 Sq. Mm ( 45Mm ) 55 Supplying And Fixing 48 ( 1200Mm ) Sweep Ceiling Fan Suitable For Operation On230 Voltsingle Phase Ac Supply I / C Connections With Suitable Sixe Of Pvc Insulated Copper Cable Etc Complete As Required ( Super Speed Es Of M / S Havellsmake Or Similar Superior Model Of Crompton / Usha / Ortem / Khaitan Make ) . 56 Supplying And Fixing 16 ( 400Mm ) Sweep Wall Mounted Oscillating Type Fanhaving 3 Speed Regulator I / C All Accessories Suitable For 230 Volt Ac Single Phase Supply I / C Connections Etc Complete As Required ( M / S Swing Of Havells Make Or Similar Superior Model Of Crompton / Usha / Ortem / Khaitan Make ) . 57 Sitc Of 600Mm X 600Mm Size Surface Type Prewired 36 W Ledfittingcomplete With All Accessories Etc.Directly On Ceiling Complete With All Accessoriesetc. I / C Connections With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Crompton Polaris Nio Iii Or Similar Model Of Superior Make ) 58 Sitc Of 4 Feet Long 20 W Led Batten Type Fitting Complete With All Accessories Etc. Directly On Ceiling / Wall I / C Connections With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Trim Linea Neu Of Crompton Make Or Similar Model Of Superior Make ) 59 Supplying & Laying Of Xlpe Insulated4 X 16 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangementas Required. 60 Supplying & Laying Of Xlpe Insulated4 X 10 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 61 Supplying & Laying Of Xlpe Insulated3 X 6 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 62 Supplying & Laying Of Xlpe Insulated3 X 2.5 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 63 Supplying And Laying 6Mm Thick Rubber Matting With Isi Mark Of Size Suitable For Lv Supply ( Isi Mark ) Etc. Complete As Required. 64 Sitc Of Heavy Duty Exhaust Fan Of 450 Mm Sweep, 1400 Rpm Speed Suitable For Operation Nf 240 Volts, 50 Hzsingle Phase Ac Supply Complete With Installation On Duct Including Making Suitable Arrangement For Fixing In Existing Ac Duct Complete With Connections Etc As Required ( Model :Turbo Force Neo 1P Of Havells Or Similar Model Of Superior Make ) 65 Supplying & Fixing400 A 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings , Thermal Release Range Of ( 320-400A ) With Spreader Terminals , Rotary Handle In The Existing Mv Panel Including Dismantling The Life Expired Tpn Sfus, Providing Suitable Structural Modification To The Cubicleand Door To Fix New Mccb With Minimum Shut Down Etc Complete As Reqd 66 Supplying & Fixing 250 A, 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings , Thermal Release Range Of ( 200-250A ) With Spreader Terminals , Rotary Handle In The Existing Mv Panel Including Dismantling The Life Expired Tpn Sfus, Providing Suitable Structural Modification To The Cubicleand Door To Fix New Mccb With Minimum Shut Down Etc Complete As Reqd 67 Supplying And Fixing 4 Way Vertical Type Tpn ( 4+4+4 ) Double Door, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Metal Door, Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Paintedi / Cfour Pole 100 A, 25 Ka ( 80-100 ) A Adjustable Mccbas Incomer Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( Incomer Mccb M / S L&T Make Model Dn0-100C Or Equivalent Similar Superior Make ) 68 Supplying, Installing, Balancing And Commissioning Of Rectangular / Round Ducting Suitable For Package Typeair Conditioning Plant Fabricated At Site With Galvanized Steel Sheetof 22 Gauge Thickness Compelete With Neoprene Rubber Gaskets, Elbows, Splitter, Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawing And Specifications Complete As Required. 69 Supplyingof One Numberxlpe Insulatedpvc Inner Sheathedaluminium Conductorarmouredcable Of 1100Vgradeconforming To Is: 7098 ( Part 1 ) 1988 With Opto Date Amendmentsof Following Size Etc As Required. 70 3.5 X120 Sq.Mm. Aluminium Conductor Armouredcable 71 3.5 X50 Sq.Mm. Aluminium Conductor Armouredcable 72 3.5 X35 Sq.Mm. Aluminium Conductor Armouredcable 73 Power Room Panel :-Supply, Installation, Testing And Commissioning Of Cubicle Type Lt Panel Suitable For 415 V, 3 Phase , 4 Wire 50 Hz Ac Supply System , Fabricated In Compartmentalised Design From Crca Sheet Steel Of 2Mm Thick For Frame Work And Covers, 3Mm Thick For Gland Plates I / C Cleaning And Finishing Complete With Powder Coating In Approved Shade, Havingmin. 500 Amps Capacity, Extensible Type Tpn Aluminium Alloy Busbars Of High Conductivity, Dmc / Smc Busbar Supports With Short Circuit Withstand Capacity Of 31Mva For 1 Sec, Bottom Base Channel Of Ms Section Not Less Than 100Mm X 50Mm X 5 Mm Thick, Lifting Hooks, Fabrication Shall Be Done In Transportable Sections, Entire Panel Shall Have Common Copper Earth Bar Of Size 25Mm X 5Mm At The Rear With 2 Nos. Earth Stud, Solid Connections From Main Bus Bars To Switch Gears With Required Size Of Aluminium Bus Bars And Control Wiring With 1.5 Sqmm Pvc Insulated Copper Conductor Cable, Cable Alleys, Cable Gland Plates In Two Halfi / C Providing Following Switchgears, Transporting From Factory To Site, Unloading, Leading Etc As Required .A ) Incoming:I ) 320 A , 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings, Thermal Release Range Of ( 250-320A ) With Spreader Terminals , Rotary Handle And Castle Key Interlock- 2 Nos.The Castle Key Interlock Shall Be Provided In The Incomers To Ensure That One Supply Is Available At A Time On Each Section Of Bus And To Eliminate Any Possibility Of Accidently Approaching Two Supplies At One Bus Section.Ii ) Digital Type Multifunction Meter Capable To Measure Parameters Likev, A, F, Pf, Kw, Kva, Old Energy, On And Run Hours, Site Selectablekwh / Kvahwith Rs 485 Portclass 0.5- 2 Nos.Iii ) Cts- Ratio 400 / 5A 15Va Cl-0.5 - 6 Nos. Iv ) Ryb Phase Indicating Led Lamps With Toggle Switch & Mcb - 2 Set.B ) Busbar:I ) Tpnaluminium Busbars Of Min 500Amps Capacity With Heat Shrinkable Coloured Sleeves And I / Cdmc / Smc Busbarcross Section, Size Supportsand Their Spacing Etc For Withstanding Faultlevel Of 31Mva For 1 Sec.C ) Outgoings:I ) 160 A, 35 Ka 4Pmccb, Ics=100% I Cu, With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 125-160 A ) , Spreader Terminals , Rotary Handle Etc - 3 Nos.Ii ) 63 A , 35 Ka4p Mccb, Ics=100% I Cu With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 40--63 A ) With Spreader Terminals , Rotary Handle Etc -3 Nos.Complete As Above Note : The Panel Drawing Shall Be Got Approved From The Engineer In Charge Before Fabrication . 74 Ac Room Panel:- Supply, Installation, Testing And Commissioning Of Cubicle Type Lt Panel Suitable For 415 V, 3 Phase , 4 Wire 50 Hz Ac Supply System , Fabricated In Compartmentalised Design From Crca Sheet Steel Of 2Mm Thick For Frame Work And Covers, 3Mm Thick For Gland Plates I / C Cleaning And Finishing Complete With Powder Coating In Approved Shade, Havingmin. 300 Amps Capacity, Extensible Type Tpn Aluminium Alloy Busbars Of High Conductivity, Dmc / Smc Busbar Supports With Short Circuit Withstand Capacity Of 31Mva For 1 Sec, Bottom Base Channel Of Ms Section Not Less Than 100Mm X 50Mm X 5 Mm Thick, Lifting Hooks, Fabrication Shall Be Done In Transportable Sections, Entire Panel Shall Have Common Copper Earth Bar Of Size 25Mm X 5Mm At The Rear With 2 Nos. Earth Stud, Solid Connections From Main Bus Bars To Switch Gears With Required Size Of Aluminium Bus Bars And Control Wiring With 1.5 Sqmm Pvc Insulated Copper Conductor Cable, Cable Alleys, Cable Gland Plates In Two Halfi / C Providing Following Switchgears, Transporting From Factory To Site, Unloading, Leading Etc As Required .A ) Incoming:I ) 250 A 36Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings, Thermal Release Range Of ( 200-250A ) With Spreader Terminals , Rotary Handle And Castle Key Interlock- 2 Nos.The Castle Key Interlock Shall Be Provided In The Incomers To Ensure That One Supply Is Available At A Time On Each Section Of Bus And To Eliminate Any Possibility Of Accidently Approaching Two Supplies At One Bus Section.Ii ) Digital Type Multifunction Meter Capable To Measure Parameters Likev, A, F, Pf, Kw, Kva, Old Energy, On And Run Hours, Site Selectablekwh / Kvahwith Rs 485 Portclass 0.5- 2 Nos.Iii ) Cts- Ratio 300 / 5A 15Va Cl-0.5 - 6 Nos. Iv ) Ryb Phase Indicating Led Lamps With Toggle Switch & Mcb - 2 Set.B ) Busbar:I ) Tpnaluminium Busbars Of Min 300Amps Capacity With Heat Shrinkable Coloured Sleeves And I / Cdmc / Smc Busbarcross Section, Size Supportsand Their Spacing Etc For Withstanding Faultlevel Of 31Mva For 1 Sec.C ) Outgoings:I ) 100 A, 36 Ka 4Pmccb, Ics=100% I Cu, With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 67-100 A ) , Spreader Terminals , Rotary Handle Etc - 6 Nos.Complete As Above Note : The Panel Drawing Shall Be Got Approved From The Engineer In Charge Before Fabrication.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
29.
Heavy Industries and Public Enterprises #10706525 Price Bid
Tender For Selection Of An Event Management Agency ( Ema ) For Inauguration Of India International Convention Centre ( Iicc ) , Dwarka, New Delhi; 1 Havan At Foyer Area 2 Havan Kund, Havan Samagri And Pandit For Havan Rituals 3 Centre Thematic Setup Of Size 10M X 10M For Havan Rituals 4 Wooden Chairs 5 Cocktail Tables For Hi-Tea Arrangements 6 Buffet Counters With Frill For Hi-Tea Arrangement 7 Q Managers 8 Floral Decoration At Foyer Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . Theme Of Floral Decoration To Be Presented In Technical Presentation. 9 2.6Mm Led Screens Of Size 16 X 12 For The Various Locations With Sound Facility 10 Riser Of Size 12 X 4 X 26 With Branding And Side Black Masking For Led 11 Sound System Of Havan Rituals For 200 Pax With Mics 12 Digital Photographers For Havan 13 Digital Videographers For Havan 14 Genset For Other Leds And Other Requirements, Including Distribution 50 Kva Along With Diesel 15 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5-Star Hotel 16 Main Event Area / Auditorium 17 2.6Mm Led Wall Of Size 100 Ft X 35 Ft For Stage Backdrop 18 Led Riser: 100 X 4 X 6 Inches High With Ply On Top, Carpet , Setup In The Main Auditorium. 19 Scaffolding Structure For Led Support 100 X 24 20 Flower Decoration On Stage. 21 Thematic Wall Of Size 20 Ft X 35 X 2 Numbers On Both Side Of Led Wall, Including Necessary Scaffolding 22 Hiring Of Show Running Team And Technical Team- Show Running Of The Entire Unveiling And Launch Ceremony Including Technical Coordination And On-Stage Flow 23 Additional Lights For Foh - Moving Heads 32, Wash - 24, Rgb Led -24 24 Techrider For Culture Artist And Other Artists 25 Sofa Seat ( High-End ) Mix Of 1, 2-, 3- And 5-Seater Sofas 26 Mozo Barricading / Fencing 27 High Platform For Media, Console And Camera Etc. 28 Mozo Barricading In Front Of Stage In D Shape For Hon’Ble Pm 29 Lightening Of Lamp By Vip 30 Q Manager 31 Genset For Main Stage Led, Including Distribution 32 ( 250 Kva+125 Kva Genset 375 Kva With Dieselups For Main Stage Led 375Kva 33 F&B Area 34 Buffet Counters With Masking & Frill 5Rft 35 5 Round Tables With 8 Banquet Chairs With High-Quality Linen 36 Cocktail Tables 37 Flower Decoration In Both Food Courts 38 Glass Water Bottles - Minimum 200 Ml 39 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5 Star Hotel 40 Media Lounge 41 Media Lounge To Be Constructed In Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, The Lounges To Have Acoustic Walls, Ceiling, Pantry With Serving Facility And Storeroom 42 Power Back-Up Dg For Media Lounge With Diesel 300Kva 43 Vip Toilets For Media Lounge 44 Facility For Live Telecast Of The Inaugural, Valedictory And Sectoral 45 Sessions In The Media Lounges. 46 Workstation With Seating Arrangements, Electric Sockets 47 Sofa Seating ( 2+1+1-Seater ) 48 Centre Tables 49 Chair For Round Table Sitting 50 Round Tables 51 Pigeonhole Rack 52 Laptop / Mobile Charging Stations 53 Computers For Media Workstations With B / W , Color A4 Size Printers 54 Stationary For Media Lounge 55 Decoration 56 Florals In Different Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . 57 Logo Theme Flags 58 Appropriate Landscaping With Plants Across The Event Venue, Ensuringoverall Ambience Decor. 59 Gallery Showcasing Neo Bharat Theme 60 Setting Up For A Special Thematic Showcase / Gallery Area For Vip Walkthrough, Depicting Journey Of Iicc And India Milestones. Displays To Include 3D Cutouts, Printed Panels, Av Screens, Plasma Screens, And Tech Engagements Arranged In Aesthetic Manner. Theme Should Be Revolving Around Neo Bharat. 61 Carpeting In Open Area / Foyer Area 62 Coir Carpeting ( New ) And Maintenance Of The Carpet To Be Done. Red Carpeting ( New ) In Pathways / Approach Routes Taken By Vvip , VipS Within Convention Centre And Outside The Venue, Inside Dmrc 15000 Sqft 63 Thematic Gate 64 Main Thematic Gate Of Length 60- 80 Ft And Height 30-40 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 65 Small Gates Depicting The Theme Of Length 20-30 Ft And Height 12-16 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 66 Emergency / Miscellaneous Services 67 Control Room For Fire, Disaster Management Etc. In Form Of A Hangar And General Lighting For Officers For Various Services. 68 Medical Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, Acoustic Walls, Storeroom, And Toilet Facility. Provision For Partition For Patient Rooms ( 10 Nos. ) , Seating Arrangement ( 05 Tables, 20 Chairs ) For Medical, Support Staff And Reception Area. 69 Power Back-Up Dg For Control Room And Medical Hangar 50 Kva With Diesel 70 Event Branded Pagodas ( 3X3 Sqm ) For Various Purposes Consisting Of Two Tables And Four Chairs Including Platform, Carpet, Dustbin, And Electrical Points. 71 Branding 72 Buntings, Banners, Scrollers, Etc. Of Appropriate Sizes At Various Locations At The Venue, As Well As Throughout The Prominent Places Of New Delhi Using Appropriate Eco-Solvent Printing Materials, Hoardings, Key Locations Shall Be Updated By Ema 73 Digital Signages For The Different Areas 74 Flex Iron Mounted Of Different Sizes In The Venue, Outside Venue And Within Dmrc Route Using Appropriate Eco-Solvent Printing Materials 50 Nos 75 Logo Of Iicc Needs To Be Installed At Various Locations Inside The Venue Of Various Sizes, Using Different Material Like Wood, Pop, Fibre, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Etc Of Different Sizes. 8X4 , 12X08, 20X12. 76 General Lighting 77 For The Entire Event Venue On Light Poles, Each Light Pole Having Of 150 Watts Metal Halide / Led Light / Rgb Light Rates Will Be Inclusive Of Wiring From The Source To Consumption Point Through Underground Cabling. 78 Collaterals 79 Invitation Design & Cards Printing With Qr Code 80 Car Stickers 81 Shuttle Stickers 82 Badges 2 Sided Printed With Punch Hole On 2 Sides & Lanyards For Organizers, Delegates, Artisans. 83 Badges & Lanyards For Volunteers / Working Team 84 Golf Carts 85 6-Seater Golf Cart With Driver And Charging Facility. 86 Shuttle Buses Electric Or Cng , 20 Seater Or Above 87 Innova Crysta Cars 88 Parking Area & Management 89 Parking Area To Be Created For 2000 Cars In The Designated Zones Per Site Layout With Proper Markings, Signages, Control Booth, Tin Barricading, Lighting, And Manpower To Control The Traffic Movement. 90 Event Branded Gate ( 24 Ft. X 18 Ft. ) For Different Parking Areas 91 Pa System For Announcements In Parking Area 92 Manpower 93 Emcee Who Would Be Proficient In Hindi And English, Artist Management, Logistics And Etc. 94 Visitor Management Including Hostesses, Volunteers, Helpers, Stage Coordinators, Hospitality Managers, Etc. Provide Uniformed And Well-Dressed Ushers On The Days Of The Event. 95 Photography & Videography 96 Complete Photography Setup ( 3 Nos ) , Videography Setup ( 5 Nos ) Using High End Cameras With Hd Live Mixing Unit, 36 Out Audio Video Di Box 97 Live Streaming Of The Entire Event, Live Relay Across All The Areas With Provision For Live Feed. 98 Multi Camera Videography With Zip Crane 99 Digital Photographers 100 Digital Videographers 101 Security Arrangements 102 Supplying, Installation And Maintenance Of Door Frame Metal Detector Machines For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan, 103 Supplying, Installation And Maintenance Of Handheld Metal Detector Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 104 Supplying, Installation And Maintenance Of Walky-Talky For The Entire Team, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 105 Supplying, Installation And Maintenance Of Baggage, Thermal Scanners Scanning Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 106 Frisking Booth For Females With Curtains 107 Complete Coverage Of Venue With Moveable And Zoomable Cctv Cameras With Monitoring Setup. 108 Human Resource Deployment 109 Security Personnel With Uniform For 24X7 Surveillance Male & Female 110 Housekeeping Team 111 Sanitization And Pest Control Of The Complete Convention Centre & Foyer Area , 3 Times In A Day, 3 Days Before The Event 112 Toilets 113 Bio-Chemical Toilet ( Male & Female ) 114 Safe Room 115 Safe Room For Vvip Around The Stage At Inaugural Hall Which Would Include Sofas, Chairs, Teapoy Tables, Flower Decoration, Water Bottles, Platform, Carpeting. ( 100 Sqm ) 116 Installations 117 Installations ( 490 Sqft ) To Serve As A Photo Opportunity; Well- Integrated On The Theme Of The Event And To Be Erected At The Most Suited Location At The Event Venue, For Maximum Engagement, Locations Needs To Be Mentioned In The Presentation 118 Miscellaneous 119 Wheelchair 120 Stone Plaque 121 Sitting Arrangement For All The Halls ( Carnation, Laburnum, Meeting Rooms At 3Rd Floor Aster Hall, Petunia Hall, Tulip Hall, Zinnia Hall, Daffodil Hall, Vvip Lounge, Furniture Lobby Area Furniture, Auditorium Area Furniture, Green Room & Artist Room Furniture, Etc ) - 2000 Pax 122 Green Room 123 Mirror In The Room For Artists 124 Table 125 Chairs 126 Cloth Hangars 127 Social Media Publicity 128 1 Content Development As Required By The Authority 2. Creation Of Event Specific Pages / Handles On Social Media3. Developing Social Media Strategy In Accordance With The Approved Branding And Publicity Plan 129 Vc Av Requirement For HonBle Pm 130 Hardware ( H.323 / Sip ) Videoconferencing System Configuration. Make: Videoconferencing Equipment Like Cisco / Poly / Panasonic Or Equivalents 131 Dedicated Lease Line Of 100 Mbps With 100 Mbps Dedicated Backup With A Different Isp Provider 132 Suitable Interface Converters To Connect Camera With Videoconferencing Systems Through Hdmi Input Supporting 1080P60 / 1080P30 133 Multiple Professional Full Hd Video Cameras With Live Mixing Setup 134 Photographers 135 Live Mixing Setup 136 Console Setup, Including Tables, Chairs, Black Masking 137 Stone Plaque => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
31.
Communications and Information Technology  #10600205 Price Bid
Supply Installation Testing Commissioning Of Package / Ductable Type Ac Units With Air Cooled Condensors Along With Low Side Works For Various Locations, Mtnl, New Delhi - 2 B ) 8.75 Tr Ductable Type Ac Unit 3 C ) 8.75 Tr Package Type Ac Unit 4 D ) 11 Tr Ductable Type Ac Unit 5 E ) 11 Tr Package Type Ac Unit 6 Supplying And Fixing Of G.I Sheet Metal Ducting I / C Air Distribution System, Complete Thickness Gauge I / C Nut Bolts & Gasket Etc. As Required. Na ) 22 Gauge G.I Sheet 7 B ) 24 Gauge G.I Sheet 8 Providing & Fixing Of 6 Mm Thick Nitrile Insulation For Thermal / Acoustic Work / Partition Application As Per Site Requirment For Duct, Wall, Room, False Ceiling Or Roof Including Adhesive, Nitrile Rubber Tape Etc As Reqd. 9 Supplying And Installation Of Supply Air Grilles With Volume Control Damper To Be Fixed In Supply Air Ducts I / C Nut Bolts Accessories Etc. 10 Supplying And Fixing Of Return Air Grille Without Vcd To Be Fixed In Return Air Path I / C Nut Bolts Etc As Required. 11 Supplying And Fixing Of Gi / Aluminum Volume Control Damper For Ac Package / Ducted Units Including Nut Bolts, Flanges Etc As Required. 12 Providing And Fixing Integral Switchgear Panel Comprising Of Starters, Contactors, On / Off Isolator For Evaporator And Condensing Units Etc As Required. 13 Providing And Fixing Of Microprocessor Based Controller Panel To Be Fitted Inside Built-In Features For Operation Of Accessories Such As Evaporator, Condensor, Compressor With Controls In Sequence Manner For Each Unit Including Display Of Parameters, Phase Correction / Reverse Phase Correction, Hp / Lp Signal Etc. Complete As Required. 14 Pressure Testing With Nitrogen , Pressure Standing For At Least 8 Hr., Vaccumzing & Commissioning With Refrigerant Gas Of Following A C Unit Complete As Reqd. Na ) 11 Tr Package / Ductable Ac Unit 15 B ) 8.75 Tr Package / Ductable Ac Unit 16 C ) 5.5 Tr Ductable Ac Unit 17 Lifting / Shifting Of Ac Unit From Ground Floor To The Required Floor I.E Upto The Required Site Situated With The Help Of Heavy Labour & Chain Pulley Block Complete As Required. 18 Micro Controller System To Operate Air-Conditioning Units In The Sequential Order Including The Features Of Room Temperature Display, Room Temperature Sensor, On Indication For Ac Unit, Time Duration Adjustment Facility, Cut In Temperature Facility As Req 19 Providing & Installing Soft / Hard Copper Pipe Including Cutting Bending, Jointing, Brazing Etc. As Required For Hot And Liquid Refrigerant. Na ) 5 / 8 20 B ) 7 / 8 21 C ) 1 1 / 8 22 Providing And Fixing Of Kini Foam Insulation / Sleeve On Copper Pipes / Drain Pipes Etc Complete As Required. 23 Minor Civil Work Such As Cutting, Widening And Making Ground Of Small Holes Etc. For Ac System Capacity As Required. 24 Supplying And Fixing Power Cabling & Control Cabling Of Pvc Insulated Pvc Shethed Copper Conductor Cable Of Following Size I / C End Termination Etc. As Required. Na ) 3 C X 2.5 Sq.Mm 25 B ) 4C X 6 Sq Mm 26 C ) 4 C X 10 Sq.Mm 27 D ) 3.5 C X 16 Sq.Mm 28 E ) 8 C X 1.5 Sq.Mm 29 Providing And Fixing Of Canvas Connection With Fire Resistance Cloth On Opening Of Blowers Of Ac Units Complete As Reqd. 30 Providing And Fixing Of 6 Swg Gi Wire For Earthing Etc 31 Fabricating & Installing Of 50Mm Wide Cable Tray Tray Made Out Of Gi / M.S. Perforated Sheet Of Heavy Duty Material Duly Painted I / C Nut Bolt, Screw, Etc. As Reqd. 32 Providing & Making Drain Arrangement For Ac Units With Following Pipe Size 25 Mm I / C Tee, Union Socket & Elbow Etc As Reqd. 33 Providing & Fixing Metallic Inter Connections For Each Circuit For Distribution Of Air From Package Unit To Main Branch For Air Distribution
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
32.
Housing Urban and Rular Development #10547526 Price Bid
Tender For Repairing And Renovation Work At Lok Kala Sangrahalaya District-Lucknow (U.P.)., 1 Reparing & renovation work at Lok Kala Sangrahalaya Distirct-Lucknow (U.P.) 2 RENOVATION WORK 3 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 4 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 5 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin- charge. 6 Supply & filling of cinder in sunken portion of building including braking in to required sizes including supply of all material, T&P required size including of supply of all material , labour, T&P required for proper completion of work. 7 Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 9 Class-150 brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work including supply of all materials, labour, tools and plants etc. required for proper completion of the work 10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 11 Thermo-Mechanically Treated bars of grade Fe-500D or more in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 12 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 13 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 14 Dismantling existing plaster including disposal of refuseas directed by Engineer-in-charge within a distance of 60 meters.(200feet) 15 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarsesand. 16 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. 17 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 18 Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 19 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. 20 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 21 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm(Anti skid/mat finished tile) 22 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm(Anti skid/mat finished tile) 23 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 24 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 25 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. 26 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 27 Providing and fixing aluminium work for doors, windows, ventilators and partitions witth extruded built up standard tubular sections/appropriate z sections and other sections of approved make conforming to IS 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctins, i.e. att top, bottom and sides with required.Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 28 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architecttural drawings and the directins of engineer-in-charge (Cost of aluminium snap beadingg shall be paid in basic item). With float glass panes of 8 mm thicness 29 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm) 30 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work 31 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. 32 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. 33 Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- ections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 34 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm, of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. 35 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 36 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 37 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 38 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 150 39 Providing and fixing Polyvinyl Chloride (PVC) pipes having thermal stability for hot & cold water supply including all PVC fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 40 90 mm dia 6 Kg Pressure 41 110 mm dia 6 Kg Pressure 42 160 mm dia 6 Kg Pressure 43 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 44 Coupler 45 90 mm 46 110 mm 47 160 mm 48 Y Fitting without door 49 90 mm 50 110 mm 51 Single Tee without door 52 90 mm 53 110 mm 54 Single Tee with door 55 110 mm 56 160 mm 57 Bend 90° 58 90 mm 59 110 mm 60 Bend 45° 61 90 mm 62 110 mm 63 Bend 90° with door 64 90 mm 65 110 mm 66 P-Trap 67 N-Trap 68 Reducer Tee 69 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) 300x16 mm 70 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 250x10 mm 71 Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 72 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 73 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 74 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 75 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 76 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 77 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 78 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 79 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 80 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 81 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 82 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 83 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 84 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 85 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors,jointed with neat cement slurry mixed with pigment to match the shade of the tiles, includingrubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 86 REPAIR OF SANITARY WORK 87 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 88 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms 15 mm nominal bore 89 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 90 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. i) 32 mm dia 91 Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms 92 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm dia 93 Providing and fixing toilet paper holder :C.P. brass 94 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 95 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 96 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 97 25 mm nominal outer dia Pipes 98 32 mm nominal outer dia Pipes 99 40 mm nominal outer dia Pipes 100 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 101 15 mm nominal outer dia pipes 102 20 mm nominal outer dia pipes 103 25 mm nominal outer dia pipes 104 32 mm nominal outer dia pipes 105 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 106 25mm dia, nominal bore 107 20 mm dia, nominal bore 108 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore 109 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 110 20 mm nominal bore 111 25 mm nominal bore 112 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 113 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 114 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore 115 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 116 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 117 Providing and fixing 100 mm sand cast Iron grating for gully trap. 118 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 119 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 120 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 121 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 122 Providing & fixing soil, waste & vent pipes. 123 75 mm diameter 124 100 mm diameter 125 REPAIR OF ELECTRICAL WORK 126 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 127 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 128 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 129 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 130 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 131 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 132 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 133 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 134 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 135 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 136 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 137 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 138 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door 139 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 140 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A 141 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 142 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 143 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 144 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 145 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 146 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 147 Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 45 watt to 50 Watt confirming to IP 65 protection complete in all respect. 148 Supply and fixing 200 AMPfour pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.- 149 Supply and fixing of 6 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect . 150 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 151 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 152 Supply & erection of Wall FanAC 230/250 Volts, 50 Hz 50w 1350 rpm including nuts, bolts, mounting frame and other accessorieswith connections etc. complete as required. 153 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 154 Repairing of old ceiling fan 155 Supply Installation , testing and Commissioning ofSplit type air-conditioning system 1.5 TR with installation of indoor units, outdoor units, Outdoor Unit/Indoor with all fittings, installation of Copper Refrigerant piping (pair), as required , duly insulated with closed cell elastomeric nitrile insulation of 9 mm thickness12.7 mm / 9.5 mm- For 1.5 TR Unit,PVC Drain Water pipe with all fittings Make-Kisan Agro/Prince/Supreme 20 mm dia, laying of control cum transmission wiring between ODU & IDU, Stands for outdoor units(Small), Core Cutting Client Scope-Jheeriall complete as per direction of Engineer-in-charge. 156 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
33.
Heavy Industries and Public Enterprises #10547140 Price Bid
Tender For Turnkey Works For Setting Up Of Amrit Pharmacy At Uttar Pradesh University Of Medical Sciences, Saifai, Etawah, Up; 1 CIVIL WORKS 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size). 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 9 Reinforced cement concrete work in column, beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 10 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto floor V level including plinth. Thermo - Mechanically Treated bars of grade Fe-500D or more 11 Centering and shuttering including strutting, propping etc. and removal of form for all heights: 12 Foundations, footings, bases of columns, etc. for massconcrete 13 Lintels, beams, plinth beams, girders, bressumers and cantilevers 14 Columns, Pillars, Piers, Abutments, Posts and Struts 15 Suspended floors, roofs, landings, balconies and accessplatform 16 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 17 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 18 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 19 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer 20 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 21 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour. Two coats 22 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 23 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two or more coats of Enamel Paint all complete. 24 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 25 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood 26 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 27 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm 28 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 29 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 30 Providing and fixing bright finished brass handles with screws etc. complete: 125 mm 31 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 32 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). 33 Providing and fixing of frameless glass door SS Patch Lock with out handle in toughened glassincluding all necessary screws etc. complete. 34 Providing and fixing both side 2 nos SS H handle having min 450 mm length in toughed glass door including all necessary screws etc. complete. 35 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) including skirting with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,complete:Size of Tile 600x600 mm 36 Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement counter opening and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge 37 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 38 ACP : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding over Aluminium rectangular tube of minimum size 50x25x2mm, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics including all required & complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in Sqm. up to two decimal places. 39 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick top cover 40 Providing and fixing ball bearing for rolling shutters. 41 Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 sqm and upto 16.80 sqm in the area 42 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. 43 12 mm cement plaster finished with a floating coat of neat cement ofmix :1:3 (1 cement: 3 fine sand) 44 Furniture Works 45 Double Level Counter:Providing and fixing Double Level Counter, first step at 750 mm from ground, 900mm wide and Counter top at 1100 mm level and 300 mm wide. 12mm thick acrylic sheet (pure white in colour) to be used for counter top on 25 mm thick prelaminated commercial ply. Display unit with 8mm thick toughened glass fascia and 18mm thick prelaminated shelves to be in built in counter with movable shutter. Counter should contain retractable keyboard trays and partitioned drawers with drawer channel, cupboard units with swing door and auto close hinges. Drawers and cupboard are to be fixed with individual locks and handles. Cable manager and leg space are also to be provided.150mm high SS glossy skirting all Complete as per the design and instructions of engineer in charge. 12mm thick toughened glass partition to be provided above counter up-to roof height with necessary counter opening. Note: Only front elevation of wooden counter will be measured. (12mm thick toughened glass will be paid separately). Make laminate: GREENLAM, MARINO or equivalent. 46 Counter Height Stools :Supply and installation at site counter height stools of following specifications :Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion.Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 47 Table: Supply and errection of Working Table 900mm length X600mm depth X750mm height made with 18mm thick prelaminated particle board with one side decorative and other side balancing lamination and all edges to be fixed with matching PVC edge beeding. Partitioned storage unit having swing door ,Partitioned cash drawer, Key board drawer and leg spaceare also to be provided with individual locks and handles, autoclose hinges, drawer channels etc. complete as per the aproved design andinstructions of engineer in charge. 48 Chair: Supply and errection of Medium back ergonomic chair with five nos. Star shaped Nylon base. Castors: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment and backrest height adjustment. Fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric. Upholstery: Heavy duty rubber backed fabric in BLACK. 49 Medicine display shelf: Providing and fixing of Open Wooden display laminated cabinets of length 900mmX height 2500mm made up of Pre-laminated MDF Board, exterior Grade-I 18 mm thick confirming to IS: 14587 with decorative lamination on both side with proper provision of racks and shelves.Bottom storage unit of 600mm deep storage shall be 750mm from the ground with display wooden shelves @150mm C/c. Upper storage unit provided with display wooden shelves @150mm C/c and 450 mm deep and height of 1750mm from the bottom storage unit. All the edges to be finished with edge band and shelves to be fixed with proper bracket holders complete as per approved layout, drawings and instruction of Engineer in Charge. Note: Only front elevation will be measured. 50 Over Head Storage Cabinet: Providing and fixing ofOver head storage cabinet ofdimension 900mmX600mmX450mm made up of Pre-laminated MDF Board, exterior Grade-I 18 mm thick confirming to IS:14587 with decorative lamination on both side including inside middle partitions and with sliding door on front side with rollers, sliding channels, handles, locks etc. All the edges to be finished with edge band and shelves to be fix with proper bracket holders complete as per approved layout, drawings and instruction of Engineer In Charge. Note: Only front elevation will be measured. 51 Slotted Angle Racks : Supply and errection of Powder coated slotted angle metalic rack having min 6 shelfs made up ofmin 40 X 40 X 2 mm size rolled steel angle posts shall have 8-mm diameter holes provided at 50-mm centre to centre.Metal shelves shall be made from mild steel sheets not less than 1.0 mm in thickness and with sufficient stiffners. Shelves shall have lipped flangeswidth of flange being 30 mm and depth of lip 15 mm .Min size of rack 900mm Length X 400mm Depth X 2000mm Height. 52 Airport Chair, 3 Seater: Supply and erection of Airport Chair (Set Of 3 In 1) having overall dimension ofLength 1720mm x width 675mm x height 850mm. Chair dimension floor to seat height 400mm and floor to arms height 600mm seat and back frame size Length 495mm x width 490mm x height 550 mm. Chair arms is made up of Stainless Steel Tube 50mm X 25mm Oval Shapes Tube 1.6mm thickness. Legs are made to 48mm Stainless Steel round Tube 2mm thickness and seat and back frame made to 19mm Stainless steel round tube 1.2mm thickness. Seat and back use to 1.2mm thickness perforated Stainless steel sheet. All the end cups are made to stainless steel glossy finish cups and using for the floor levellers 10mm nylon adjustable bush. 53 DISPLAY WORKS 54 Backlit Acrilic Board with projected channel letters: Supply, installation, testing and commissioningof weatherproof backlit acrilic board with projected channel letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc. Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly. All fabrication and fixing should be done as per approved design and instructions of Engineerin Charge. (Note: Only front elevation will be measured.) 55 Vinyl TransparentVision Glass Stickers: Supply and pasting of Vinyl Transparent Vision Glass Stickers in approved size and design in glass partition and door as per the instruction of Engineer in Charge. 56 PVC flex board: Supply and fixing of PVC flex board in approved size and design including all the required steel frames and fixings as per the instruction of Engineer in Charge. 57 Providing & sticking/pasting of printed vinyl wall stickersas per approved size anddesign at all heights includes all the required as per the instruction of Engineer in Charge. 58 CAPITAL/SUPPLY ITEMS 59 Supply,Installation,testingandCommissioning of Desktop computers with following specification. Processor:12th or Higher Gen Intel® Core™ i5 - (30 MB cache, 16 cores) Memory:16 GB: 2 x 8 GB, DDR5 Video Card: Intel® Graphics Storage:1 TB, M.2 2230, PCIe NVMe, SSD, Class 35 OS: Windows 10/11 Pro English Chassis:Mini Tower, Wired Multimedia Keyboard and Mouse Integrated Wireless LAN Integrated Gigabit LAN Monitor 21.5 LED or higher. Make : Dell / HP or equivalent 60 SITC of All in One PC Client PC Configuration, BRAND (DELL/HP)12th Gen Intel® Core™ i3-12400 (18 MB cache, 4 cores, 8 threads, 2.5 GHz to 4.5 GHz Turbo), memory *8 GB: 1 x 8 GB, DDR5, Storage:512 GB, M.2 2230, PCIe NVMe, SSD, Class 35, OS: Windows 11 Pro English, Multimedia Wired Keyboard, Optical Mouse, 2 USB 3.2 Gen 1 ports, Integrated Wireless LAN, Monitor 21.5 LED or higher. 61 LaserjetMultifunctionalMonochromeNetwork Printer: Supply and Installation at site, All in One LaserjetMultifunctionMonochromePrinter havingLCDDisplay,withfunctionstocopy, print and scan, print resolution 600 dpi x 600 dpi, 20ppmprintspeed,Dutycycleminimum8000 pages per month, 24 bit depth, USB, Wi-Fi connectivity.Make:hp/brother/canon/epsonor equivalent, for Bill Printing cum Office use with Warrantyperiodofoneyear.Connectivity:Hi- speedUSB 3.0Supported,Wi-Fi,Media Types: Paper, envelopes, labels, cardstock, transparencies, postcards, Functionality: Print, Scan/Copy.Power Consumption:Maximum 250 WattsRecommended Make : hp/brother/canon/epson or equivalent 62 Laserjet Monochrome Network Printer : Supplyand Installation at site, Laserjet MonochromePrinterhavingLCDDisplay,with functions to copy and print, printresolution 600 dpix600dpi,20ppmprintspeed,Dutycycle minimum8000pagespermonth,24bitdepth, USB,Wi-Ficonnectivity.Make: hp/brother/canon/epson or equivalent 63 Visi Cooler / Pharmacy refrigerator : Supply, errection and commisioning of lab / pharmacyrefrigiratorasperfollowing specifications:UprightShowcase Coolers/refrigerators with Single Glass Door and Lock having 350-450 Litre capacity, Temperature range capability 1-10 degree celsius with Digital TemperatureControllerandDisplay,Minimum of 4 adjustable Shelves/Racks Recommended Make:CELFROST,BLUESTAR,VOLTAS, THERMO FISCHER 64 Cash Counting Machine cum Fake Note Detector Make : Optimus-Model No.OLC 04 or equivalent 65 CashSafe(Coffer)Volume.14LMin WallThickness: 2.5 mm min for body and 5 mm min for door Recommended Make: Godrej make, ModelNo.PremiumCofferBRN(ltemCode: SEBP1112) or equivalent (only manual lockinq system) 66 CounterCommunicationSystem:Supply, installation, testing and commisioning of two way countercommunicationsystemincluding speaker,mike,controlunit,powerunitetcall required (make : Ahujaccs 2300 or equivalent) 67 WaterDispenser:Supplyanderrectionofwater dispensercanhold20litrewaterbottlehaving normalstanding designwith14liter refrigerator atbottom andhaving3temperaturetapshot, plain and cold. 3 liter cooling and 5 liter heating capacity per hour. Body made of ABS plastic and tankmadeofFoodgradestainlesssteel.Heavy duty bottle piercer with bottle holder. withmin 1 year warranty. (Make : voltas / Blue star/ equivalent) 68 Supply of ABC Type fire extinguisher of 2 Kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 69 Electrical Work 70 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 71 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Recommended Material : Polycab, RR Kabel, V Guard, Havells) 72 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.( Recommended Material : RR Kabel/National/ Ralison/RKG/ Finolex / Polycab / Havells) 73 2 x1.5 sq.mm + 1x 1.5 sq. Mm earth wire 74 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 75 2 X 6 sq. mm + 1 X 6 sq. mm earth wire meter 76 Supplying and fixing 3 pin 5 A ceiling rose on the exising junction box / wooden block including connections as required. 77 S/F light plug point modular type accessaries : Supplying and fixing suitable size GI box with modular plate and cover in fronton surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required, 78 S/F Power plug point with modular type switch : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 and 15/16 amps modular switch, connection,painting etc as required. 79 S/F 20A SPN MCB industrial socket outlet : Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 80 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 81 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):12 way, Double door. 82 S/F C series, MCB : Supplyingand fixing5 amps to 32 amps rating, 240/415volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioningetc. as required. 83 Single pole 84 Single pole and neutral 85 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 86 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp including cable termination 87 Supply, Installation, testing & commissioning of branded best qualityThree phaseelectronic type energy meter with LCD display with battery back up.withall connections complete, Make:L&T or Equivalent . 88 S/F C series, MCB : Supplyingand fixing5 amps to 32 amps rating, 240/415volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioningetc. as required. Triple pole 89 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 90 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 91 Supply,installation,testingandcommissioningofthe following types oflight fittings with all accessorieson false ceiling, true ceiling or wall as directedand giving connectionswith 16/0.20 mm 3 core PVC insulated andsheathedroundcopperconductorflexwireor extendingthe original wiring and giving connectionsas required. All recessed type fixtures are to be supportedindependentlywith chains or GI wire anchoredto the ceiling with anchoring bolt of necessary size. All loose wires above the false ceiling are to be neatly concealed by flexible metal/pvc conduits.( cost to include lamps & all consumables also) 92 Supply and installtion of 30-36W, 230V, 4300 lumen, Recessed Square LED Cool White light fixture of dimession 600mm X 600mm on false ceiling along with all accessories with intergrated driver THD<10% and connections as well as making good the damages as required at site Engineer. Recommended makes: Philips/Crompton/Wipro or equivalent. 93 Supply and installtion of LEDtubelight of6000K and 20-24W on wall or ceiling as directedand giving connections as required.All loose wires are to be neatly concealed. (Make: Philips, Wipro, Crompton or equivalent) 94 Supply and installtion of 10-15W, 230V, Recessed Square or Round LED Cool White light fixture on false ceilling along with all accessories with intergrated driver THD<10% and connections as well as making good the damages as required at site Engineer. Recommended makes: Philips/Havells/Wipro or equivalent. 95 Supply, Installation, testing and commissioning of wall mount fan (400mm sweep), adjustable speed. min 60 degree oscillation, swing, Adjustable upward and downward tilt mechanism, Protective Guard, Including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, mounting accessories, etc. as required. It shall be double ball bearning type. (Make: USHA, Cromption ,Havells) 96 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 97 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 98 Network / LAN 99 S/F Modular boxes, base & cover plate : Supplying and fixing 1 or 2 module ( 75 mm x 75 mm), GI box along with modular base, cover plate for modular switches in recess etc as required. 100 Providing and Fixing of RJ-45 socket outlet in the existing modular box with connections and all required. 101 16Port Network Switch :Supply, Installation, testing and commissioning of: 10/100 Mbps 16-Ports Gigabit Switch . ( Make : D-Link DGS-1008A) 102 Supplying,drawing and crimping with all accessories of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable from Port Switch to Data socket 103 Supply, installation, testing and commissioning of best quality cat-6 patch cord having1 metre length complete as per specifications as required. 104 Supply, installation and commissioning of powder coated DVR 4U Wall Mounted ServerRack ofISO Standard of size 550 x 350 x 140 mmhaving depth adjustable mounting slots, top and bottom Panel with ventilation and cable entry facility, provision to mount the cooling fans on the top panel, lock and key etc. and having capacity to carry a max Load of 60 kg all complete as per the manufacturer specifications and instructions of Engineer In Charge. 105 CCTV 106 Supply, Installation, Testing & Commissioning ofIndoor IR Dome night vision cameras :2.0 MP, 0.1 lux, Resolution 720 P ,AWB/ BLC/ AGC,min 20m range, Built-in IR illumination, white color case, PAL-CE/FCC approved. Make: CP PLUS/HIKVISION/Honeywell or equivalent 107 Supply, Installation, Testing & Commissioning of Outdoor IR Bullet night vision camera :2.0 MP,0.1 lux, Resolution 720 P,AWB/ BLC/ AGC ,min 20m range, Built-in IR illumination, white color case, DC12V, PAL-CE/FCC approved. Make: CP PLUS/HIKVISION/Honeywell or equivalent 108 Supply ,Installation ,Testing & commissioning of SMPS Power supply unit for above camera as speficied by camera manufacturer -12VDC 10A 109 Supply ,Installation ,Testing & commissioning of Digital Video Recorder : 8-Channel Embedded HD DVR, 400fps, Real-time, with 2 TB HDD and English OSD, 230VAC. Rate shall be inclusive of all accessories, termination of cables, etc complete. 110 Supply ,Installation ,Testing & commissioning of 15 to 16LED Color Monitor. make :LG / Samsung/ Equivalent. 111 Supply and Laying ofCoaxial cable 2+1 RG59/RG6 premium quality CCTV power and video cable with ISI marked PVC conduit including terminations with suitable BNC Connector, power Jack etc complete. 112 AC 113 Inverter Air Conditioner: Supply, installation, testing and commissioning of Air Cooled Cassette Air Conditioner of following capacity consisting of indoor room unit with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressorfor operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room unit on ceiling, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room& condenser as per site conditions, comprising of 1 or 2 dia drain PVC pipe with insulation 3m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigarant gas, suitable stabilizer etc complete as required. ( Make : Voltas , Blue Star, LG, Samsung, Carrier,Hitachi ) :Minimum 3TR 3 star rated as per BEE 114 Supply and Installation of additional copper piping, cabling and drain piping for air conditioning unit with proper insulation including all required on wall/above false ceiling complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
34.
Road Transport and Highways #10501906 Price Bid
Upgradation Of Copa Lab. In Lala Hans Raj, Iti Narela, Delhi Under Imc Fundsh: Elecrtrical Work ) --- 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (DSR 2016)a)Group C 2 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required (DSR 2016) 3 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR 2016) 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as requireda) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR 2016) 5 b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wir e(DSR 2016) 6 c)4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire (DSR 2016) 7 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR 2016) 8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2016)a) 16 way , Double door 9 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2016)a) Single pole 10 Supplying and fixing following rating, double pole, 240 V/415 V, isolator/MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A (DSR 2016) 11 b) 100 A(4P) (DSR 2016) 12 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR 2016)a) 25 mm 13 Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. (DSR 2016) 14 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75 mmX75 mm) (DSR 2016) 15 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (DSR 2016) 16 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings) (DSR 2016) 17 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (DSR 2016) 18 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.(DSR 2016) 19 Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required (DSR 2016) a) 2 X 6 sq. mm (19mm) 20 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2016) 21 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required (DSR 2016) 22 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (DSR 2016)a) 1 run of cable 23 b) 2 run of cable (DSR 2016) 24 c) 3 run of cable (DSR 2016) 25 Supplying ofPVC insulated PVC sheatheredAl. conductor, armouned cable 1.1 KV grade of following sizesas reqda) 2x6 sqmm 26 Supply & fixing of 2’x 2’size of 36 watt LED light panel fittings suitable for operation 220 volts single phase AC supply with the help of chain complete with driver etc. i/c connection,testing etc. as required 27 Supplying, installation, testing and commissioning of 1200mm (48”)sweepceiling fan suitable for operation on 220 volts single phase AC supply i/c wiring the down rod of reqd. size with 1.5 sqmm FRSPVC insulated, copper conductor single core cable etc. as reqd. 28 S/I/T/C of Exhaust fan (12”) heavy duty steel body suitable for operation on 220 volts single phase AC supply in the existing opening etc. complete as required 29 Supplying, installation, testing and commissioning ofwall mounted inverter split air conditioning unit of 2TR capcity having cooling capacity of not less 24000 Btu/hr. with necessary copper piping and cabling (up to 3 meter length),microprocesser controlled indoor unit with with cordless remote controller, outdoor unit with hermaticaly sealed energy effeciantrotary compressor, copper coil condenser suitable for operation on 220/230 V(single phase) AC supply complete as required at site. 30 Providing and fixing MS frame of suitable sixe for mounting out door condenser unit of split AC i/c painting etc. completeas required 31 Supplying and fixing suction and discharge refrigerent copper pipe line suitable for2 TR capacity split ACunit i/cnitrile insulation, brazing etc. completeas required 32 Supply, Installation, Testing and Commissioning of 9U rack with PDU strip (5Amp) cable manager on the wall with the help of hole fasteners etc 33 Supply ,Installation ,Testing and Commissioning of D Link/Neat gear 48 ports 10/100/1000LANswitch in the existing Rack including, connection ,testing etc. asrequired.a) 24 Ports 34 b) 8 Ports 35 Supply and fixing of Patch Card of following sizes including testing, connection, etc complete as required ( DLINK)a) 1 Meter 36 S/crimping of RJ-45 jack i/c testing etc. as red. (M/s D.Link) 37 S/FInformation Outlet with face plate (D.Link make) 38 S/FPatch cord CAT-6 (1 Mtr) D.Link make 39 Add 21.46% on DSR items amounting to Rs. 105421 40 Less 9.50% on DSR items amounting to Rs. 128044.35
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
35.
Housing Urban and Rular Development #10488345 Price Bid
Tender For Annual Repair Maintenance Of Various Electrical And Mechanical At 325 Bedded Bhagwan Mahavir Hospital Pitampura New Delhi Under Ae ( E ) Pwd Hmesd North I - Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 2 20 Mm 3 25 Mm 4 32 Mm 5 40 Mm 6 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 7 6 Module ( 200Mmx75mm ) 8 8 Module ( 125Mmx125mm ) 9 12 Module ( 200Mmx150mm ) 10 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. 11 6 Module 12 8 Module 13 12 Module 14 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 15 8 Way , Double Door 16 12 Way , Double Door 17 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 18 6 Way ( 4 + 18 ) , Double Door 19 8 Way ( 4 + 24 ) , Double Door 20 Providing And Fixing H.T. Danger Notice Plate Of 250 Mm X 200 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. 21 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required. 22 For 10 Way, Double Door Spn Mcbdb 23 For 14 Way, Double Door Spn Mcbdb 24 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc.As Required. 25 For 8 Way, Double Door Tpn Mcbdb 26 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 27 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 28 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 29 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Sizeon Wall Surface As Required. 30 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 31 Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 32 Above 95 Sq. Mm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 33 Above 185 Sq. Mm And Upto 400 Sq. Mm ( Clamped With 40X3mm Ms Flat Clamp ) 34 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 35 2 X 16 Sq. Mm ( 22Mm ) 36 3½ X 35 Sq. Mm ( 32Mm ) 37 3½ X 50 Sq. Mm ( 35Mm ) 38 3½ X 70 Sq. Mm ( 38Mm ) 39 3½ X 95 Sq. Mm ( 45Mm ) 40 3½ X 120 Sq. Mm ( 45Mm ) 41 3½ X 185 Sq. Mm ( 57Mm ) 42 3½ X 240 Sq. Mm ( 62Mm ) 43 3½ X 300 Sq. Mm ( 70Mm ) 44 3½ X 400 Sq. Mm ( 82Mm ) 45 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 46 Group C 47 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 48 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 49 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. 50 Group C 51 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 52 3 X 1.5 Sq. Mm 53 3 X 4 Sq. Mm 54 6 X 4 Sq. Mm 55 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 56 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 57 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. 58 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 59 150 A, 16 Ka, Tpmccb 60 250 A, 35 Ka, Tpmccb 61 Supplying And Fixing Of Pole / Wall Mounted Enclosure Of Size 240 X 130 X 110 Mm Deep Made Out Of Sheet Moulding Compund ( Smc ) Dust And Weather Proof With Front Openable Hinged Tube Corner Complete With Locking Arrangement And 2 Nos. M.S Clamps Including Providing And Fixing Of 1 No. 6 Amp C Series Sp Mcb Mounted On Din Bar, 2 Nos 20Mm X 5 Mm Thick Al. Strip As Reqd. 62 Supplying Installtion Testing And Connection Of Abs Body Geyser Having Glass Lined Tank Of Capacity 25 Ltr, 2 Kw Heating Element, Bee 5 Star Rating , Glass Coated Heating Element, Double Protection With Thermal Cut Out & Multi Function Safety Valve Suitablefor 230 Volt 50 Hz Ac Supply Complete With Dash Fastener, Pvc Connection Complete Etc As Required. 63 Supplying, Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Followingsize Aluminium Conductor Armoured Cable On Wall Surface As Required. 64 3 X 10 Sq. Mm 65 4 X 16 Sq. Mm 66 Provision For Supplying And Installation Ofoil Type Room Heater Having Approximate 12-13 Fins, Overheat Protection, Thermostatic Heat Control, Quick Heating With Ptc Fan And Castor Wheels For Easy Mobility Etc As Required. 67 Painting ( Two Or More Coats ) On Air Conditioning & Fire Fighting Pipes Of Following Sizes And Fittings With Synthetic Enamel Paint Including A Primer Of Red Oxide / Zinc Chromate Complete As Required. 68 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 69 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 70 Supplying & Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Armoured Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( A ) 4 X 25 Sq Mm 71 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 72 Less Credit For Following Old Dismantled Items Of Assorted Sizes For Items Installed Against The Same 73 Steel Conduit Assorted Size 74 Gi Box Assorted Size 75 Mcb Distribution Board Assorted Size 76 Frls Pvc Copper Conductor 77 Cat6 Lan Wire 78 Assorted Mcbs, Mccbs 79 Armoured Aluminium Cable 80 Geyser
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Daman And Diu View Result →
36.
Rural Development #10406378 Price Bid
Tender For Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Kune Nama.(For One Year), Tal. Maval, Dist. Pune - Supplying and erecting modulartype switch6A / 10A 2 2-7-5 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. inlength along with pole cap of 300 mm length 100 mm dia dulywelded as per specification no. FG-BKT/BPC 3 16-3-9 Making M- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Labour Chrages for LED fitting on Street light or MS light pole. 14 Dismentaling Charges -LED street light of pole. 15 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 16 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 17 Supplying & Laying armoured cable 4C X 6 Sq.mm. 18 7-1-28 Supplying, erecting & terminating FR XLPE insulated,galvanised steel formed wire armoured (strip) cable 1100 V, 4core 10 sq. mm. aluminium conductor complete erected withglands & lugs, on wall/ trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL 19 Supplying & Layingarmoured cable 2C X 10 sq mm 20 Supplying & Layingarmoured cable 4C X 16 sq mm 21 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 22 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 23 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 24 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 25 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 26 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 27 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 28 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 29 Polycrystalline 330/335 Watt 12 V Solar Panel With 10 year Manufacturing Defect, 25 years degradation 30 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 31 25 Amp, 32 Amp Three Phase L/T Contactor 32 2.5 Sq. mm Multistand Copper Wire 33 Insulation Tape 34 9-1-4 Providing pipe type earthing with 40mm. dia. G.I. pipe or20 mm dia. G.I. Rod complete with all materials testing andrecording the results as per specification no. EA-EP 35 Street Light Pole Box FRP 36 Cement Street Light Pole Clamp 37 M.S. Street Light Pole Clamp 38 LED Street light Arm bend pipe 39 Small Size FRP box for MCB 40 Big Size FRP box for MCB 41 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 42 Servicing And Primary Maintenance For Street Light Pole. 43 Light Poles painting in Silver Colour 44 26W LED Light To 100W LED Light Repairing 45 Old Pole Shifting, Rework and Foundation Work per Pole etc. 46 Supply &Fixing of Shakle Hardware with Nut Bolt 47 Supply and Installation of Mini Feeder Pillar with Stand 48 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 49 Tree Triming for Overhead Line 50 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 51 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 52 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 53 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 54 8-2-13 Providing & erecting 7 m high (clear height) galvanisedoctagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 55 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 56 Printer toner cartridge 57 Tricolor 18-Meter LED Rope Light | Indian Tricolor Strip Light - Orange + White + Green Colour in Single Strip | Independence Day 18 Meter Plug and Play Waterproof Strip Light, Pack of 1 58 Inverter repairing-1850/2250/3/4/5KVA 59 3-2-10 (New) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 60 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 61 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 62 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 63 GI Tar for service wire support with bobine. 64 Kit kat Type fuse 16A 32A 63A 120A 65 Taparia Tester 66 Spaner Set 67 Control Panel HRC Fuse 68 Supplying And Erecting Transformer Fidder Piller 69 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 70 Solar inveter 2250VA 71 Solar inveter 1850VA 72 Solar Tubular Battery-200AH 73 Solar Tubular Battery-165AH 74 UPS System an Ideal Power Backup & Protection 75 Ink Tank printer ink set 76 A4 Rim
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
38.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Oct 30, 2024 Contract Value : 44.40 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
40.
Rural Development #10381500 Price Bid
Tender For Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Somatane., Tal. Maval, Dist. Pune - 1 Supplying and erecting modulartype switch6A / 10A 2 2-7-5 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. inlength along with pole cap of 300 mm length 100 mm dia dulywelded as per specification no. FG-BKT/BPC 3 16-3-9 Making M- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Labour Chrages for LED fitting on Street light or MS light pole. 14 Dismentaling Charges -LED street light of pole. 15 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 16 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 17 Supplying & Laying armoured cable 4C X 6 Sq.mm. 18 7-1-28 Supplying, erecting & terminating FR XLPE insulated,galvanised steel formed wire armoured (strip) cable 1100 V, 4core 10 sq. mm. aluminium conductor complete erected withglands & lugs, on wall/ trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL 19 Supplying & Layingarmoured cable 2C X 10 sq mm 20 Supplying & Layingarmoured cable 4C X 16 sq mm 21 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 22 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 23 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 24 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 25 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 26 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 27 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 28 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 29 Polycrystalline 330/335 Watt 12 V Solar Panel With 10 year Manufacturing Defect, 25 years degradation 30 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 31 25 Amp, 32 Amp Three Phase L/T Contactor 32 2.5 Sq. mm Multistand Copper Wire 33 Insulation Tape 34 9-1-4 Providing pipe type earthing with 40mm. dia. G.I. pipe or20 mm dia. G.I. Rod complete with all materials testing andrecording the results as per specification no. EA-EP 35 Street Light Pole Box FRP 36 Cement Street Light Pole Clamp 37 M.S. Street Light Pole Clamp 38 LED Street light Arm bend pipe 39 Small Size FRP box for MCB 40 Big Size FRP box for MCB 41 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 42 Servicing And Primary Maintenance For Street Light Pole. 43 Light Poles painting in Silver Colour 44 26W LED Light To 100W LED Light Repairing 45 Old Pole Shifting, Rework and Foundation Work per Pole etc. 46 Supply &Fixing of Shakle Hardware with Nut Bolt 47 Supply and Installation of Mini Feeder Pillar with Stand 48 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 49 Tree Triming for Overhead Line 50 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 51 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 52 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 53 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 54 8-2-13 Providing & erecting 7 m high (clear height) galvanisedoctagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 55 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 56 Printer toner cartridge 57 Tricolor 18-Meter LED Rope Light | Indian Tricolor Strip Light - Orange + White + Green Colour in Single Strip | Independence Day 18 Meter Plug and Play Waterproof Strip Light, Pack of 1 58 Inverter repairing-1850/2250/3/4/5KVA 59 3-2-10 (New) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 60 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 61 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 62 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 63 GI Tar for service wire support with bobine. 64 Kit kat Type fuse 16A 32A 63A 120A 65 Taparia Tester 66 Spaner Set 67 Control Panel HRC Fuse 68 Supplying And Erecting Transformer Fidder Piller 69 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 70 Solar inveter 2250VA 71 Solar inveter 1850VA 72 Solar Tubular Battery-200AH 73 Solar Tubular Battery-165AH 74 UPS System an Ideal Power Backup & Protection 75 Ink Tank printer ink set 76 A4 Rim
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
41.
Rural Development #10381385 Price Bid
Tender For Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Gahunje - 1 Supplying and erecting modulartype switch6A / 10A 2 2-7-5 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. inlength along with pole cap of 300 mm length 100 mm dia dulywelded as per specification no. FG-BKT/BPC 3 16-3-9 Making M- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Labour Chrages for LED fitting on Street light or MS light pole. 14 Dismentaling Charges -LED street light of pole. 15 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 16 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 17 Supplying & Laying armoured cable 4C X 6 Sq.mm. 18 7-1-28 Supplying, erecting & terminating FR XLPE insulated,galvanised steel formed wire armoured (strip) cable 1100 V, 4core 10 sq. mm. aluminium conductor complete erected withglands & lugs, on wall/ trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL 19 Supplying & Layingarmoured cable 2C X 10 sq mm 20 Supplying & Layingarmoured cable 4C X 16 sq mm 21 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 22 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 23 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 24 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 25 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 26 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 27 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 28 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 29 Polycrystalline 330/335 Watt 12 V Solar Panel With 10 year Manufacturing Defect, 25 years degradation 30 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 31 25 Amp, 32 Amp Three Phase L/T Contactor 32 2.5 Sq. mm Multistand Copper Wire 33 Insulation Tape 34 9-1-4 Providing pipe type earthing with 40mm. dia. G.I. pipe or20 mm dia. G.I. Rod complete with all materials testing andrecording the results as per specification no. EA-EP 35 Street Light Pole Box FRP 36 Cement Street Light Pole Clamp 37 M.S. Street Light Pole Clamp 38 LED Street light Arm bend pipe 39 Small Size FRP box for MCB 40 Big Size FRP box for MCB 41 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 42 Servicing And Primary Maintenance For Street Light Pole. 43 Light Poles painting in Silver Colour 44 26W LED Light To 100W LED Light Repairing 45 Old Pole Shifting, Rework and Foundation Work per Pole etc. 46 Supply &Fixing of Shakle Hardware with Nut Bolt 47 Supply and Installation of Mini Feeder Pillar with Stand 48 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 49 Tree Triming for Overhead Line 50 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 51 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 52 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 53 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 54 8-2-13 Providing & erecting 7 m high (clear height) galvanisedoctagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 55 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 56 Printer toner cartridge 57 Tricolor 18-Meter LED Rope Light | Indian Tricolor Strip Light - Orange + White + Green Colour in Single Strip | Independence Day 18 Meter Plug and Play Waterproof Strip Light, Pack of 1 58 Inverter repairing-1850/2250/3/4/5KVA 59 3-2-10 (New) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 60 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 61 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 62 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 63 GI Tar for service wire support with bobine. 64 Kit kat Type fuse 16A 32A 63A 120A 65 Taparia Tester 66 Spaner Set 67 Control Panel HRC Fuse 68 Supplying And Erecting Transformer Fidder Piller 69 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 70 Solar inveter 2250VA 71 Solar inveter 1850VA 72 Solar Tubular Battery-200AH 73 Solar Tubular Battery-165AH 74 UPS System an Ideal Power Backup & Protection 75 Ink Tank printer ink set 76 A4 Rim
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
42.
Rural Development #10355686 Price Bid
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Somatane., Tal. Maval, Dist. Pune(For 31 March 2025) , Supplying And Erecting Modulartype Switch6a / 10A , 2-7-5 Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt/Bpc , 16-3-9 Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 6M To 8M High Octagonal /Conical Gi Pole). , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No.Oh-Pl/Stp , Supplying And Erecting Street Light Bracket Made From 25Mm. Dia ‘B’Class G.I. Pipe, 0.6M. In , Supplying And Erectingled Street Light Fitting Suitable For 36W To 40W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 . , Supplying And Erecting Led Street Light Fitting Suitable For 50W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65. , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65. , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95,Class Ip 65 , Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With Pf > 0.95,Class Ip 65 , Providing Rental Basis Hydraulic Bucket Vehicle Of Hight 13 Mtr. And Weight Capacity 200 Kg. With Driver, Oprator And Disel Etc. For Per Day Basis , Labour Chrages For Led Fitting On Street Light Or Ms Light Pole. , Dismentaling Charges -Led Street Light Of Pole. , 1.25 Mm Crca Sheet Metal Enclosures Box For Timmer And Mcb , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm , Supplying & Laying Armoured Cable 4C X 6 Sq.Mm. , 7-1-28 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying & Layingarmoured Cable 2C X 10 Sq Mm , Supplying & Layingarmoured Cable 4C X 16 Sq Mm , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series (For Lighting) 5-3-3 , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries (For Lighting) 5-3-7 , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” & Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete… , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block/Provided Box, With Necessary Materials. 4-4-3 , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole. , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Polycrystalline 330/335 Watt 12 V Solar Panel With 10 Year Manufacturing Defect, 25 Years Degradation , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 Amp Three Phase L/T Contactor , 2.5 Sq. Mm Multistand Copper Wire , Insulation Tape , 9-1-4 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Street Light Pole Box Frp , Cement Street Light Pole Clamp , M.S. Street Light Pole Clamp , Led Street Light Arm Bend Pipe , Small Size Frp Box For Mcb , Big Size Frp Box For Mcb , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes(Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Rcc Road Cheasling Charges With Tractor Breaker (1 Hours) , Tree Triming For Overhead Line , 7-1-33 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 70 Sq. Mm. Aluminium Conductor , 7-1-31 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 35 Sq. Mm Aluminium Conductor , 7-1-34Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 95 Sq. Mm Aluminium Conductor , 7-1-35 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 120 Sq. Mm Aluminium Conductor , 8-2-13 Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , 5-3-9 Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series (For Lighting) In Provided Distribution Board As Per Specification No. Swswr/ Mcb , Printer Toner Cartridge , Tricolor 18-Meter Led Rope Light | Indian Tricolor Strip Light - Orange + White + Green Colour In Single Strip | Independence Day 18 Meter Plug And Play Waterproof Strip Light, Pack Of 1 , Inverter Repairing-1850/2250/3/4/5Kva , 3-2-10 (New) Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , 7-9-7 Supplying & Erecting Crimping Type Copper Lugs For Cable 120 Sq.Mm. Complete As Per Specification No. Cb-Cl/Cu , 4-4-5 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. , Cable Joint Kit For Armoured Cable 20 Upto 120Sq. Mm Cable , Gi Tar For Service Wire Support With Bobine. , Kit Kat Type Fuse 16A 32A 63A 120A , Taparia Tester , Spaner Set , Control Panel Hrc Fuse , Supplying And Erecting Transformer Fidder Piller , 5-2-19 Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14/16 Swg Sheet, Outdoor Type, Three Phase, 415V Consisted Of Suitable Rating Contactor, 24 Hrs Digital/ Astronomical Time Switch With Minimum 5 Years Battery Backup, Tpn Mcb 63 A Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / Cc Foundation. , Solar Inveter 2250Va , Solar Inveter 1850Va , Solar Tubular Battery-200Ah , Solar Tubular Battery-165Ah , Ups System An Ideal Power Backup & Protection , Ink Tank Printer Ink Set , A4 Rim
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
43.
Housing Urban and Rular Development #10350254 Price Bid
Tender For Supply And Cable And Other Minor Work In Reginal Training Center (Ripa) At Bikaner (Ew) - S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 20 mm 3 Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 1.5 sq.mm x 3 core 5 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 6 50mm x 50mm x 6mm 7 P & Fixing Powder coatedCRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and makingholes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 8 2.0 mm thick 9 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 Double pole MCB(With B/C curve tripping Characteristics) 11 6 A to 32 A rating 12 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 13 Electrolytic grade Aluminium bus bar 6010 grade 14 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 4 pole MCCB With Thermal Magnetic release 16 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 17 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 18 6.0 Sq. mm 19 2 core 20 35.0 Sq. mm 21 3.5 core 22 50.0 Sq. mm 23 3.5 core 24 400.0 Sq. mm 25 3.5 core 26 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 27 S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 28 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 29 50 mm 30 110 mm 31 Supply & Laying following size B class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 32 100 mm dia. 33 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 34 Surface Mounting (with extruded alumn. Housing ) 35 Minimum lumen output 2400 lm 22 W 36 Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 37 Minimum lumen output 1000 lm10W 38 Providing & Fixing of IP - 65 protectedimpact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 x 450x 132 mm 40 Charges for Providing of experienced and Highly skilled/ skilled/semi-skilled/ Un skilledlabour for electric repair/ maintenance/operation of Air conditioning /Air cooling / Fire fighting /Lift/D G set /CCTV/EPABX or any other electromechanical services/ systems as required.( One shift of 8 Hours per day ) 41 Skilled Labour 42 Semi skilled labour 43 Un skilled labour 44 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 45 Single pole MCB (With B/C curve tripping Characteristics) 46 6 A to 32 A rating 47 Four pole MCB (With B/C curve tripping Characteristics) 48 50/63 A rating 49 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50 Metal door (Three phase) IK-09 and IP-43with Metal end box 51 4 Way 52 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 53 LED Street Light fixture with Minimum lumen output 8700 lm70W 54 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 40 mm Dia. 56 Providing & Fixing of1200 mm sweepBLDC technologypower savingceilingfanwhich can withstand on votage fluctuationsfrom 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10%and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe up to 80 cm, cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 57 Without Remote 58 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 59 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 20W 60 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 61 4 pole MCCB With Thermal Magnetic release 62 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 63 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 64 17.2 mm thick and 3 Mtr. Long 65 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 66 32mm x6mm G.I. ( Hot Dipped) Strip 67 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 68 10 SWG G.I. ( Hot Dipped) Wire
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
44.
Civil Aviation #10292355 Price Bid
Tender For Miscellaneous Electrical Works At Datia Airport.; 1 Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Micro- processor based Constant Current Regulator(CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/ inter-connections etc. and confirming to tenders technical specifications complete as required.a) 4 KW, 6. 6A output current. 2 Supply of single core x 6 sq. mm sizes 5 KV grade PVC insulated & PVC sheathed, antitermite & anti- rodent,multi-strandedcopperconductorsinglecoreairfieldlightingcableconfirmingtoIS 1554 (Part II) with up to date amendments complete as required. 3 Supply of 4 core x 25 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 4 Supply of 3 core x 16 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 6 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV grade of 6 sqmm size in the existing RCC/GV/ DWC HUME/ METAL pipe etc. as required. 7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 8 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sqmm 9 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm 10 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Up to 35 sqmm 11 Supply of 5 KV grade plug and receptacle ,suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core 6 sq. mm copper conductor AGL cable complete etc. as required. 12 Making connections of 5 KV grade, 6 Sq. mm Copper conductor AFL cables withplug and receptacle connector i/c crimping & fixing, applying HT tape complete as required. 13 SITC of Mini Remote Control Desk havingprovision for control of PAPI both side landing T and windsock and 1 CCR spare i/c MIMIC display etc. complete as required. 14 Supply and fixing of 24 core X 1.5 Sq. mm Copper conductor armoured 1.1 KV grade XLPE insulated PVC Sheathed control cable as per IS 7098 Part-1 1988 as amended upto date as per site requirement. 15 Supply, Erection and termination CRCA sheet 3mm powder coated control cable end termination junction box to be mounted on wall 300mm X 200 mm X 500mm 16 Earthing with G. I. pipe 4.5 m long x 40 mm dia. (Drilling of 300 mm dia, 4.5 Mtr deep by using Borewell machine) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. includingcharcoal or coke and salt complete as required. 17 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections complete etc. as required. 19 Supplying and fixing following DB- Phase Segregated DB 12 Way Double Door 8 Incomer 4+4+4 Sub Incomer 12+12+12 Outgoing, of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted, IP54 including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 20 Supplying and fixing distribution board of 12way double door SP, steel sheet for 230 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 21 Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPN MCB 22 Supplying and fixing 32 amps rating, 240/415 volts, C curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 Supplying and fixing following rating, two pole,230 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 24 Supplying and fixing 6 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 25 Supplying and fixing 16 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 26 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 27 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 28 Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 29 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. 5 pin 5/6 A & 1 no. twin 6/16 A modular socket outlet and 1 no. 5/6 A & 1 no. 15/16 A modular switch, connections etc. as required. 30 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 5 pin 5/6 Amodular socket outlet and 2 no. 5/6 Amodular switch, connections etc. as required. 31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. twin 6/16 A modular socket outlet and 1 no. 15/16 A modular switch, connections etc. as required. 32 Supply of energy efficient 5 star rated BLDC ceiling fan, 1200 mm sweep remote operated suitable for operation on 240V, 50Hz A.C. supply with down rod canopies etc. complete as required. (Maximum power consumption - 28W) 33 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 34 Supply of energy efficient wall fan Hiflo Wave Plus 60W KD White Wall Fan Sweep: 400 mm suitable for operation on 240V, 50Hz A.C, complete as required. (Maximum power consumption - 60W) 35 Installation, testing and commissioning of wall mount fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. complete as required. 36 Supply of 230 mm sweep metallic exhaust fan suitable for operation on 240V, 50Hz A.C. supply, 1400 rpm with all accessories including louvers, shutters etc. complete as required. 37 Installation of exhaust fan of size 230 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 38 Supply of minimum 15 Watt recessed mounting LED downlight with minimum output 1500 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 39 Supply of minimum 30 W LED recessed 2ft X 2ft luminaire with minimum output 3000 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 40 Supply of minimun 40 W LED street light fitting with minimum output of 4400 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have High pressure die cast Aluminium /Standard alloy housing. Luminaire should have Air vents in housing for proper thermal management, Min IP protection should be IP 65. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent / LED Fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 42 Supply, Installation, Testing & Commissioning of 2 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenser connected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 43 Supply, Installation, Testing & Commissioning of 1.5 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenserconnected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 44 SITC of Floor Standing RO Purifier Chiller & Dispenser having RO + UF + TDS Control with minimum Flow Rate 30L/hr and storage 20L Tank complete as required 45 SITC of 1.5kVA stand-alone solar power system having 3no. 530Wp monocrystalline solar panel,1no. 24V 1.5kVA solar inverter with MPPT feature, 2no. 150Ah solar tubular batteries, complete with DCDB box, earthing, Lightning arrestor installation and module mounting structure and associated all cabling complete etc. as required.Preferred make-TATA POWER or equivalent. 46 Supply of 3 core x 4 Sqmm. XLPE insulated PVC sheathed armoured copper conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 47 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 100 mm water cooled Borewell Submersible pump set- with associate accessories. 48 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 6-10A DOL water cooled Borewell Submersible Pump Starter with associate accessories. 49 Supply, Installation, Testing and Commissioning of following sizes of CI butterfly valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required 50 150 mm dia. 51 100 mm dia. 52 80 mm dia. 53 Supply, Installation, Testing and Commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming toIS-1239/ IS-3589, including cutting, welding, nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. and fixing the pipes onwall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. 54 150 mm dia. 55 100 mm dia. 56 80 mm dia. 57 Supply, Installation, Testing and Commissioning of MS structural support for Above ground piping and pump room manifold 58 Supply of fracture bed designed to provide firm, even support for patients with fractures. Bed to be made of mild steel with a powder-coated finish having features for allowing for changes in height and position and includes wheels for easy mobility within the hospital setting 59 Supply of healthcare semi fowler bedmade of mild steel with a powder-coated finish having feature to bend bed from mid. 60 Supply of suitable semi fowler 2 section mattress for healthcare bed with minimum 4inch thickness. The mattress to have non hygroscopic outer cover which is easy to clean such as artificial leather cover.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
Madhya Pradesh View Result →
45.
Rural Development #10289661 Price Bid
Supplying Material For Grampanchayat Burambad Tal Sangmeshwar Dist Ratnagiri For The Year 2020-21 And 2021-22. ( 15Th Finance ) -1 Burambad Gram. Pt. Installation Of 4 X 1.5 Cement Benches At Bus Stops And Public Places Within The Boundaries. 2 Burambad Gram. Pt. Installation Of 4 X 1.5 Cement Benches At Bus Stops And Public Places Within The Boundaries. 3 Purchase Of Water Filter For Burambad Health Sub-Centre Year 2021-22 | Aqua Pure 16 Ltr 4 Purchase Of Office Table For Burambad Health Sub-Centre Year 2021-22 3 X 2 Ms 5 To Provide Financial Assistance Or Materials Or Machinery For Personal Business / Industry To Underprivileged Sections Widows, Women, Disabled, Agricultural Laborers And Backward Class Persons. ( Garghanti ) Laxmi Company 6 To Provide Financial Assistance Or Materials Or Machinery For Personal Business / Industry To Underprivileged Sections Widows, Women, Disabled, Agricultural Laborers And Backward Class Persons. ( Sewing Machine ) Usha / Singer Company 7 Burambad Gram. Pt. Distribution Of Dustbins To Households Within ( Wet Waste And Dry Waste Year 2021-22 10 Ltr Paras 8 Burambad Gr.Pt. Necessary Furniture, Chairs, Benches, Etc. Buying | Or G. Pt. Office Beautification In 2020-21 And 2021-22. ( Table ) 3 X 2 Ms 9 Burambad Gram. Pt. Necessary Furniture, Chairs, Benches, Etc. Buying And Gr.Pt. Office Beautification In 2020-21 And 2021-22. | ( Chairs ) Armless Plastic Cello Company 10 Burambad Gram. Pt. Necessary Furniture, Chairs, Benches, Etc. Buying Or Gram.Pt. Office Beautification In 2020-21 And 2021-22. ( Other Embellishments ) 11 Gram.Pt. Air Conditioning ( Ac ) In Your Government Service Center. Year 2020- | 21 Liyod 1 Tan Ac And Compressor 12 Gram.Pt. Air Conditioning ( Ac ) In Your Government Service Center. Year 2021- | 22 Alloyed 1.5 Tan Ac And Compressor
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
46.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
47.
Power #10206343 Price Bid
mtps i bm unit iii annual overhauling 2025 26 overhaul of esp ab and cd pass internals and related works- 1 Checking the rapping mechanisms both emitting and collecting replacing/Re-conditioning eroded tumbling hammers etc. 2 Charges for checking, replacing/re-conditioning worn out/bent shock bar guides both front and rear wherever necessary. 3 Charges for checking, replacing/re-conditioning worn out shock bar after providing necessary scaffolding arrangements 4 Charges for checking, replacing/re-conditioning of worn out pin wheel assembly. 5 Charges for checking, replacing /reconditioning of worn out plain bearing in CRM and ERM horizontal shafts etc. 6 Charges for renewal ofworn-out / deteriorated / damaged/fallen gas distribution screen plates from ESP primary and secondary side including the provision of scaffolding arrangements, cutting gas etc. 7 Charges for renewal / reconditioning of fallen Deflection plates over the primary / secondary screen plates. 8 Charges for providing hug bolt in the second collecting electrode to support shock bar and welding of bolt & nut including charges for bolt & nut. 9 Charges for cleaning the accumulated ash inside the ESP hoppers 10 Charges for replacing / reconditioning the worn out EERM shafts with structure, tumbling hammers, bush bearings with necessary scaffolding arrangements aligning the shafts plain bearings, bush bearings and tumbling hammers checking the rapping mechanisms both emitting and collecting replacing / reconditioning of eroded tumbling hammers. 11 Charges for Cutting & removing thedamaged bottom portion, fabrication & fixing the new plate for the collecting electrodes with fasteners. 12 Replacing of eroded/snapped Emitting electrodes 13 Inner arm Hammer assembly For CRM & ERM of ESP 14 Outer arm with hammer assembly for CRM of ESP 15 Plain bearing for ESP 16 Cutting gas 17 Welding Rod 18 Consumables and T & Ps
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
49.
Rural Development #10104638 Price Bid
Tender For Electrification Works.- 1 Supplying And Erecting G.I. Strip Of Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint In An Approved Manner With Joint Required. As Per Specification No ( Ea-Ep ) . ( Csr No. 9 - 2 - 3 ) 2 Supply, Installation, Testing And Commissioning Of Maintenance Free Earthing Comprising Of Electrode Of 17.2 Mm Diameter Low Carbon Steel With 250 Micron Molecular Copper Bonded Earthing Rod Of Length 3M Along With 25 Kg Carbon Based Environment Friendly Back Fill Ground Enhancing Compound Required To Fill Up The Excavated Earth With Required Quantity Complete. Specification No. Ea-Mobi ( Csr No. 9 - 1 - 5 ) 3 Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 70 Sq. Mm. Aluminium Conductor With Continuous 8.35 Sq. Mm. ( 10 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al ( Csr No.7-1-18 ) 4 Supplying, Erecting & Terminating Pvc Armoured Cable 4 Core 6 Sq Mm Aluminium Conductor With Continuous 5.48 Sq Mm ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al ( Csr No.7-1-27 ) 5 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 10 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al ( Csr No. 7-1-28 ) 6 Providing & Erecting 3 Pole Mccb Of 200A, 415V Capacity With Short Circuit Rating 25 Ka ( Ics=100% Of Icu ) Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure On Iron / Gi Frame As Per Specification No. Sw-Swr / Mccb ( Csr No. 5-5-2 ) 7 Supplying And Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) Surface / Flush Mounted Sp / Tp Mcbs Of 12 Ways On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb ( Csr No. 5-4-4 ) 8 Supplying Erecting And Marking Four Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A In Provided Distribution Board. ( Csr No. 5-3-16 ) 9 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No. 5-3-3 ) 10 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No. 5-3-17 ) 11 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No. 5-3-3 ) 12 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No. 5-3-17 ) 13 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) Surface / Flush Mounted Suitable For Spmcb Of 12 Ways, On Iron Frame / Wooden Board. ( Horizontal Type ) As Per Specification No. Sw-Swr / Mcbdb ( Csr No. 5-4-1 ) 14 Providing, Erecting & Commissioning Rccbonly Of Electro Magnetic Type With 30 / 100 / 300 Ma Sensitivity And Having Capacity Of 40A. 4 Pole Complete As Per Specification No. Sw-Rccb / Rccb ( Csr No. 5-6-5 ) 15 Supplying, Erecting & Marking Spn Mcb 6A To 32A, C- Series ( For Motor / Power ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No. 5-3-10 ) 16 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( Csr No.5-3-17 ) 17 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) Surface / Flush Mounted Suitable For Spmcb Of 24 Ways, On Iron Frame / Wooden Board. ( Horizontal Type ) As Per Specification No. Sw-Swr / Mcbdb ( Csr No. 5-4-2 ) 18 Providing, Erecting & Commissioning Rccb Of Electro Magnetic Type With 30 / 100 / 300 Ma Sensitivity And Having Capacity Of 63A. 4 Pole Complete As Per Specification No. Sw-Rccb / Rccb ( Csr No. 5-6-6 ) 19 Providing, Erecting & Commissioning Rccb Of Electro Magnetic Type With 30 / 100 / 300 Ma Sensitivity And Having Capacity Of 40A. 4 Pole Complete As Per Specification No. Sw-Rccb / Rccb ( Csr No. 5-6-5 ) 20 Ceiling Fan ( 2.12.21 ) Supplying And Erecting Five Star Rated Energy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm Complete Erected In Position As Per Specification No. Fg-Fn / Cf ( Csr No. 2-12-21 ) 21 Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400Rpm With Condensor Complete Erected In Position With Necessary Materials. Fanmotor With Moisture Proof Treatment And ‘E’ Class Insulation And Marking Sr. No. & Date Of Erction. ( Csr No. 2-12-15 ) 22 Supplying And Erecting ‘B’ Grade G.I.Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Two Core Flexible Cable 24 / 0.2 Mm Copper Pvc Wire. ( Csr No.2-13-6 ) 23 Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. ( Csr No. 2-13-4 ) 24 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. ( Foot Light ) ( Csr No. 2 - 10- 10 ) 25 Supplying And Erecting T8 Fluorescent Tubeday Light 600Mm 18 W ( Tube Light ) ( Csr No. 2-10-1 ) 26 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. ( Wall ) ( Csr No. 2-10-10 ) 27 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. ( Csr No. 2-10-13 ) 28 Supplying Led Concealed Type Foot / Step Light With Pvc Body For Indoor Application Suitable For Upto 5 W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface ( Csr No. 2-1-15 ) 29 Supplying & Erecting T8 Led 18W Tube Light Fitting ( 4 Feet ) Withpolycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver Complete ( Including Lamp ) . ( Csr No. 2-1-22 ) 30 Supplying And Erecting 1 Light Fancy Wall Bracket With Arm Fabricated From Brass Duly Lacquered With Suitable Holder And Fancy Glass Shade Duly Wired Erected On Wall With Suitable Size Of Polished Wooden / Laminated Board. ( Csr No. 2-2-9 ) 31 Supplying And Erecting Square Shaped Crca / Die-Cast Aluminium Powder Coated Housing Led Panel Light ( Slim Edge-Lit ) Suitable For 9 W - 12 W With Provision For Plane Front Frame With Translucent Cover Fixed To The Housing Complete. ( Csr No. 2-1-7 ) 32 Point Wiring For Light / Fan / Bell In 20 Mm Isi Marked Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire With Flush Type Switch And Required Accessories As Per Specification No: Wg-Pw / Sw ( Csr No. 1-9-6 ) 33 Point Wiring For Independent Plug In 20 Mm Isi Marked Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw ( Csr No.1-9-8 ) 34 Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Isi Marked Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Fr Grade Copper Wires, Modular Type Switch And Socket, Earthing And Required Accessories As Per Specification No Wgpw / ( Csr No. 1-9-11 ) Sw 35 Supplying And Erecting Modular Type T.V. Socket Single Outlet Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Csr No. 1-8-14 ) 36 Supplying And Erecting Modular Type Telephone Socket One Gang With Safety Shutter Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete ( Csr No. 1-8-15 ) 37 Supplying & Erecting Telephone Cable 2 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing / Conduit Asper Specification No. Wg-Tw ( Csr No. 1-10-1 ) 38 Supplying, Erecting & Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs As Per Specification No. Wg-Tw ( Csr No. 1-11-1 ) 39 Supplying And Erecting Modular Type Computer Jack Rj 45 With Safety Shutter Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( Csr No. 1-8-17 ) 40 Supplying & Installing Utp Networking Cat-6 Cable Suitable For Lan / Wan Computer Net-Working As Per Specification No. Wgcoc / Nc ( Csr No. 1-12-1 ) 41 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( Csr No. 1-8-11 ) 42 Supplying And Erecting Modular Type Switch 16 / 20 A With Indicator, Isi Mark, Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( Csr No. 1-8-6 ) 43 Supplying & Erecting Mains With 2X2.5 Sq.Mm.And Earth Wire 1.5 Sq.Mm Frls Pvc Copper Wire In Rigid Pvc Conduit Min.20Mm Dia. As Per Specification No: Wg-Ma / Pc, Para No. 1.4.1 ( Csr No. 1-6-4 ) 44 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Morter / Pop As Per Required To Match The Background In An Approved Manner. ( Csr No. 1-8-36 ) 45 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( Csr No. 1-8-11 ) 46 Supplying And Erecting Modular Type Switch 16 / 20 A With Indicator, Isi Mark, Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( Csr No. 1-8-6 ) 47 Supplying & Erecting Mains With 2X4 Sq.Mm.And Earth Wire 2.5 Sq.Mm Frls Pvc Copper Wire In Rigid Pvc Conduit Min.20Mm Dia, As Per Specification No: Wg-Ma / Pc, Para No. 1.4.1 ( Csr No.1-6-6 ) 48 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Morter / Pop As Per Required To Match The Background In An Approved Manner ( Csr No. 1-8-36 ) 49 Split Type A.C. ( 3.2.9 ) Supplying, Installing, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Having Iseer Minimum 4.50 Suitable To Operate On250v, 50 Cycles, A.C. Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete With Refrigerant R410 A / R32 And Copper Condensor At Position. Specification No.Apac / Sac ( Csr No. 3-2-8 ) 50 Supplying And Erecting Storage Type Horizontal / Vertical Water Heater 15 Litres Capacity With Bee 5 Star Rating High Impact Resistance Engineering Plastic Body On Wall / Loft Complete Duly Tested And Marking Sr. No. And Date Of Erection. Specification No. Ap-Wh / Stwh ( Csr No. 3-1-1 ) 51 Supplying And Erecting, Testing And Commissioning Solar Cum Natural Water Cooler Suitable For Hot And Dry Weather Nominal Cooling Capacity Of 50 Litres Along With Solar Panel, Fan For Cooling, Copper Storage Tank And Copper Coils With Water Spraying Arrangement Complete. Specification No. Apwcr / Solar Wc ( Csr No. 3-3-7 ) 52 Supplying And Erecting Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps With Output Of Purified Water 7 To 8 Litre / Min With Activated Carbon Filter And Softener Operating On 230 V Single Phase A.C. Supply ( Csr No. 3-5-1 ) 53 Supplying And Erecting Gate / Garden Light Fitting With 200Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fg-Odf / Glt ( Csr No. 2-6-1 ) 54 Supplying And Erecting Led Street Light Fitting 12 To 18 W, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification No Fg-Odf / Fls-2 ( Csr No. 2-5-1 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
50.
Educational and Research Institute #10088358 Price Bid
Supply Of Books , Library Books , Machine Design, T. V. Sundararajamoorthy & N. Shanmuga ,Anuradha Publications, Kumbakonam. , Revised Edition June-2003 , Industrial Motor Control., Stephen Herman ,Cengage Learning , 6Th Edition , Electrical Technology, Edward Hughes ,Addision– Wesley International Student Edition , Latest Edition , Mysql, Paul Dubois ,Addison Wesley , 4Th Edition , No Sql Distilled, Pramod J. Sadalage Martin Fowler ,Addison Wesley , 1St Edition Or Latest Reprint , American Society Of Metals – Hand Book – Volume 4 ( Forming), American Society Of Metals,American Society Of Metals , Latest Edition , Programmable Controller Theory And Implementation, L.A.Bryan E.A.Bryan ,An Industrial Text Company Publication , Latest Edition , Biomedical Instrumentation, M. Arumugam ,Anuradha Publications, Chennai , Latest Edition , Android Apps For Absolute Beginners, Jackson ,Apress , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Arasan Ganesan Institute Of Technology , 1993 , Home Refrigeration And Air Conditioning, Audels, Theo. ,Audel & Co. Publisher, New York. - 1998 , 199 Edn.49 , Remote Sensing And Geographical Information System, M.Anji Reddy ,B.S Publications , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , 1997 , Exploring Programmable Logic Controller With Applications, Pradeep Kumar Srivastava ,Bpb Publication , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , Latest Edition , Advanced Mobile Repairing, Pandit Sanjib ,Bpb Publication , First Edition 2010 , Modern Vcd Video Cd Player Introduction, Servicing And Troubleshooting, Manohar Lotia & Pradeep Nair ,Bpb Publication , Latest Edition , Explosing Programmable Logic Controllers With Application., Pradeep Kumar Srivastava. ,Bpb Publication , Latest Edition , Let Us C, Yeswanth Kanetkar ,Bpb Publication , 16Th Edition , Programmable Logic Controller, Pradeep Kumar & Srivashtava ,Bpb Publication , Latest Edition , Modern Computer Hardware Course, Manahar Lotai, Pradeep Niar, Payal Lotia ,Bpb Publication , Second Revised Edition 2011 , Inside Autocad, D. Raker And H. Rice,Bpb Publication , Latest Edition , Text Book Of Environmental Science And Technology, M.Anji Reddi ,Bs Publications , Latest Edition , Book 1 - General Aspect Of Energy Management And Energy Audit,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , Book 3 - Energy Efficiency In Electrical Utilities,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , National Building Code Of India – 2005,,,Bureau Of Indian Standards, New Delhi , Latest Edition , Total Quality Management, Oakiand.J.S.,Butterworth Heinemann Ltd. Oxford , 1989 , The Art Of Electronics, Paul Horowitz ,Cambridge University , 2Nd Edition Press , Performance And Design Of Ac Machine, M.G.Say ,Cbs Publisher & Distributor , Latest Edition , A Text Book Of Soil Mechanics, Dr S B Sehgal ,Cbs Publisher & Distributors , Latest Edition , Building Repair And Maintenance Management, P.S.Gahlot ,Cbs Publisher & Distributors (P) Ltd , Latest Edition , Learning Material Development Project – Nitttr,,Cd Programme On Gps And Gis. , Latest Edition , Introduction To Programmable Logic Controllers, Gary Dunning ,Cengagelearning India Pvt Ltd , Latest Edition , Building Materials, S.C.Rangwala ,Charotar Publishing House , 1982 , Building Construction, S.C.Rangwala ,Charotar Publishing House , Latest Edition , Mechanics Of Structures (Vol Ii), S.B. Junnarkar ,Charotar Publishing House , 22Nd Edition , Highway Engineering, Rangwala ,Charotar Publishing House , 2010 , Railway Engineering, Rangwala ,Charotar Publishing House , 2010 , Bridge Engineering, Rangwala ,Charotar Publishing House , 2009 , Estimating & Costing, Rangawala ,Charotar Publishing House , Latest Edition , Construction Of Structures And Management Of Works, Rangwala.S.C ,Charotar Publishing House , Latest Edition , Machine Design, Pandya & Shah ,Charotar Publishing House , 1995 , Principle Of Geographical Information Systems For Land Resources Assessment, Burrough P.A. (2000) ,Clarendon Press, Oxford. , Latest Edition , Technician’S Guide To Programmable Logic Controllers, Richard A. Cox ,Delmer , Sixth Edition 2011 , Principles Of The Manufacturing Of Composite Materials , Suong V Hoa, ,Des Tech Publication. Inc , Latest Edition , Strength Of Materials, S.Ramamirtham ,Dhanpat Rai , 2003 , A Course In Electrical And Electronics Measurements And Instrumentation., A.K. Sawhney Puneet Sawhney ,Dhanpat Rai , Latest Edition , Estimating & Costing, L.N.Dutta ,Dhanpat Rai , Latest Edition , Thermal Engineering., B.K. Sarkar. ,Dhanpat Rai , 3Rd Edition , Internal Combustion Engines, M.L.Mathur & R.P.Sharma ,Dhanpat Rai , Latest Edition , Mechanical Draughtsmanship,G.L. Tamta, Dhanpat Rai ,Dhanpat Rai , Latest Edition , Engineering Drawing, D.N. Ghose ,Dhanpat Rai , Latest Edition , A Course In Electrical Power, Soni & Gupta ,Dhanpat Rai , Latest Edition , Hydraulics,Fluid Mechanics And Hydraulics Machines, S. Ramamirtham ,Dhanpat Rai , Latest Edition , Modern Electric Traction, H Partab ,Dhanpat Rai , Latest Edition , Mechanical Measurements, A.K.Sawhney-Dhanpat Rai & Sons ,Dhanpat Rai , Latest Edition , Electronic Measurements And Instrumentation, Sanjay Talbar & Akhilesh Upadhyaya ,Dhanpat Rai , 2004 , Electrical And Electronic Measurements And Instrumentation, A.K.Sawheney ,Dhanpat Rai , 1993 , A Coursein Electricalpower, Soni, Gupta ,Dhanpat Rai , Latest Edition , Strength Of Materials, S. Ramamrutham ,Dhanpat Rai , 15 Edn 2004 , Course In Electrical Machine Design, A.K.Sawhney ,Dhanpat Rai , Latest Edition , Electrical Technology, B.L.Theraja ,Division Of Nirja Constructions And Dev Co.(P) Ltd , 1994 , Design Data Book, Psg College Of Technology ,Dpv Printers, Coimbatore , Latest Edition , Suftware Testing Concepts And Tools, Nageshwara Rao Pusulri ,Dreamteach , First Edition , Automotive Mechanics, Joseph Heitner ,East West Press (P) Ltd, New Delhi , Latest Edition , Renewableenergy Sources , Twidell, J.W. And Weir, ,Efn Spon Ltd , Latest Edition , Vehicle And Engine Technology, Heinz Heisler ,Elbs , Latest Edition , Programmable Logic Controller, W. Bolton ,Elsevier India Pvt Ltd , Iv Edition , Principles And Practice Of Town And Country Planning, Lewis B. Keeble ,Estates Gazette, University Of Michigan , 2010 , A Text Book On Building Services, R.Udyakumar ,Eswar Press, Chennai , Latest Edition , Fluid Mechanics, K.L.Kumar ,Eurasia Publshing House - New Delhi , Latest Edition , A Text Book Of Machine Design., R.S. Khurmi & J.K.Gupta ,Eurosia Publishing House - New Delhi ,Edn. 18 , Mechanical Measureme Control, R.V. Jalgaonk ,Everes T Publishing House, Pune , Latest Edition , The Cell Phone Handbook, P.J. Stetz And Penelope Stetz ,Findtech Ltd , Second Edition , Pc Repair And Maintenance, Joel Rosenthal ,Fire Wall Media, New Delhi , First Edition 2007 Reprint :2012 , Software Engineering, Bharat Bhusan Agarwal, Sumit Prakash Tayal ,Fire Wall Media, New Delhi , Second Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , Multimedia Technology & Applications,, David Hillman ,Galgotia Publications Pvt Ltd. , Latest Reprint , Repair And Seismic Strengthening Of Buildings - Guidelines, Is:13935 - 2002,,Guidelines, Is:13935 , 2002 , Automotive Mechanics, William H.Crouse And Donald .L. Anglin ,Hill Publishing Company Ltd, New Delhi , Latest Edition , Die Design Fundamentals, Paquin.J.R,,Industrial Press Inc , Latest Edition , Digital And Analog Communication System, B.P.Lathi .Zhi Ding ,International Oxford University Press , 4Th Edition , Mysql Bible, Steve Suehring ,John Wiley & Sons , 2002, Latest Reprint , Modern Production / Operations Management, E.S. Buffa And R.K. Sarin ,John Wiley & Sons , Latest Edition , Remote Sensing And Image Interpretation, Lillesand, T.M. & Kiefer R.W. (1998) ,John Wiley & Sons , Latest Edition , Ground Water Hydrology, David Keith Todd ,John Wiley & Sons , Latest Edition , Digital Communications, Simon Haykin ,John Wiley India Edition , Latest Edition , Cad/Cam, Mikell P.Groover ,Jr.Prentice Hall Of India Pvt., Ltd. , Latest Edition , A Course In Electrical Power, J.B. Gupta ,Kaison Publishing House , Reprint 2004 , Civil Estimating, Costing And Valuation,,Kalson Publishing House , Latest Edition , Machine Drawing, P.S. Gill ,Katsan Publishing House , Latest Edition , Analysis Of Structures – Vol 1, Vazirani & Ratwani ,Khanna Publishers , Latest Edition , Quantity Surveying & Valuation, N.A.Shaw ,Khanna Publishers , Latest Edition , Water Supply And Sanitary Engineering, S.K.Garg ,Khanna Publishers , Latest Edition , Hydrology And Water Resources Engineering, Santhosh Kumar Gar ,Khanna Publishers , Latest Edition , Fluid Mechanics, Prof. S. Nagarathinam - ,Khanna Publishers , Latest Edition , Workshop Technology ,Raghuwanshi,Khanna Publishers , Latest Edition , Production Technology,Nai Sarak ,Khanna Publishers ,Edn. Xii , Thermal Engineering, P.Lballaney ,Khanna Publishers , 24Th Edition , Production Technology, Jain & Gupta ,Khanna Publishers , Latest Edition , Automobile Engineering, G.B.S.Narang ,Khanna Publishers , Latest Edition , Thermal Engineering, P.L Ballaney,Khanna Publishers , 24Th Edition , Applied Thermodynamics, Domkundwar And C.Pkothandaraman ,Khanna Publishers ,2Nd Edition , Non Conventional Energy Sources, G.D. Rai,Khanna Publishers , 1999 , Industrial Engineering And Management, O.P. Khanna ,Khanna Publishers , Latest Edition , Refrigeration And Air Conditioning, P.L . Ballaney ,Khanna Publishers , Latest Edition , Electric Circuit Theory, Dr.M.Arumugam Dr.N.Premkumaran ,Khanna Publishers , Latest Edition , Electrical Power, S.L Uppal ,Khanna Publishers , Latest Edition , Electrical Wiring, Estimating And Costing, Dr.S.L.Uppal G.C. Garg ,Khanna Publishers , Sixth- 2011 , Electric Circuit Theory, M. Arumugam, N. Premkumaran ,Khanna Publishers , 1997 , Power Electronics, P.S.Bimbhra, ,Khanna Publishers , 5Th Edition 1994 , Integrated Circuits, K.R. Botkar ,Khanna Publishers , Latest Edition , Satellite Communication, D.C. Agarwal ,Khanna Publishers , Third Edition , A Monograph On Electronic S Design Principles,, N.C.Goyel, R.K.Khetan, ,Khanna Publishers , Second Edition , Operating Systems, Ekta Walia ,Khanna Publishers , 2Nd Edition , Data Structures, Rs Salaria ,Khanna Publishers , 2016 , Electric Power, Sl Uppal ,Khanna Publishers , Latest Edition , Testing, Commissioning, Operation And Maintenance Of Electrical Equipments, S.Rao ,Khanna Publishers , Sixth Edition, 2010 , Electrical Estimation And Costing, Surjit Singh ,Khanna Publishers , Latest Edition , Power Electronics, Dr.P.S.Bimbhra ,Khanna Publishers , Fourth Edition, 2011. , Mechanical & Indtrial Measuments, R.K.Jain ,Khanna Publishers , Latest Edition , Construction Management, Sanga Reddy. S ,Kumaran Publications, Coimbatore , Latest Edition , Fluid Mechanics, R.K. Bansal ,Lakshmi Publications , Latest Edition , Total Quality Management,, V.Jayakumar ,Lakshmi Publications. , (Reprint 2005) , Thermal Enggi., R.K . Rajput,Laxmi Publications Pvt Ltd , 8Th Edition , Fluid Mechanics And Hydraulic Machines, R. K. Bansal ,Laxmi Publications Pvt Ltd , Latest Edition , Engineering Mechanics, R K Bansa ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Dr. B.C. Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Ashokkumar Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume I, Punmia.B.C. Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , 2011 , Theory Of Structures, B.C. Punmia, Ashok Jain & Arun Jain ,Laxmi Publications Pvt.Ltd. , 9Th Edition , Surveying Volume I, Punmia.B.C, Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume Ii & Iii, Punmia.B.C, Ashok Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Limit State Design Of Reinforced Concrete, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , R C C Designs, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Environmental Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Waste Water Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Soil Mechanics And Foundation Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Project Planning And Control With Pert And Cpm, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Buildingconstruction, Dr.B.C.Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Strength Of Materials, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 3Rd Edition, 2010. , Engineering Mechanics, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 2Nd Edition, 2007 , Thermal Engg, R.K .Rajput ,Laxmi Publications Pvt Ltd , 8Th Edition , Industrial Robotics – Technology, Programming And Applications, P.Groover ,Mc Graw Hill , 2001 , Mobile Cellular Communications, W.C.Y. Lee ,Mc Graw Hill , Second Edition , Electronic Principles And Applications, Charles.A.Schuler ,Mc Graw Hill , 3Rd Edition, 1989 , Geotechnical Earthquake Engineering Hand Book, Robert W.Day ,Mc Graw Hill , Latest Edition , Measurement Systems Application And Design, Ernest O. Doebelin ,Mc Graw Hill , 2004 , Transducers And Instrumentation, D.V.S.Murty ,Mc Graw Hill , 2004 , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , Latest Edition , Digital Integrated Electronics, Taub & Schlling ,Mc Graw Hill , Latest Edition , Optical Fibre Communication, Gerd Keiser ,Mc Graw Hill , Third Edition , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , 1994 , Computer Control Of Manufacturing Systems, Yoram Koren ,Mc Graw Hill , Latest Edition , Engineering Economics And Management, T.R. Banga & S.C. Sharma ,Mc Graw Hill , Editiion 2 – 2001 , Database System Concepts, Silberschatz A. And Korth H ,Mcgraw Hill Education (India) Pvt Limited , 6Th Edition , A Global Perspective, Heinz Weihrich, Harold Koontz ,Mcgraw Hill International Edition ,10Th Edition , Hessentials Of Management’, Herald Koontz And Heinz Weihrich ,Mcgraw Hill Publishing Company , Latest Edition , Power Electronics, Md Singh, Kb Dhanchandaniata ,Mcgraw Hill Publishing Company , Seventeenth Reprint 2005 , Operating Systems, A Concept-Based Approach, Dhananjay M. Dhamdhere ,Mcgraw Hill, Indian Edition , 3Rd Edition , Elements Of Photogrammetry, Wolf Paul (1998) ,Mcgraw Hill, New Delhi , Latest Edition , Manufacturing Process, Begeman . ,Mcgraw Hill, New Delhi1981. , 5Th Edition , Introduction To Environmental Engineering, Mackenzie, L. Davis And A. David, Cornwell. ,Mcgrawhill , Latest Edition , Environmental Engineering, Peary, Rowe And Tchobanoglous ,Mcgrawhill , Latest Edition , Fundamentals Of Digital Logic With Vhdl Design, Stephen Brown And Vranesic ,Mcgrawhill , Latest Edition , Programmable Logic Handbook: Pld, Cpld, And Fpga, Ashok K.Sharma ,Mcgraw-Hill , Latest Edition , Javascript: The Complete Reference, Powell, Thomas ,Mc-Grawhill , 3Rd Edition , Html & Css: The Complete Reference, Thomas Powell ,Mc-Grawhill , 5Th Edition , Jsp: The Complete Reference, Phil Hanna ,Mc-Grawhill , 2Nd Edition , Robotics For Engineers, Yoram Koren ,Mcgraw-Hill Book Co., , 1992 , “Basic Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Advanced Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Hand Book Of Die Design, Ivana Suchy ,Mcgraw-Hill Book Company , Latest Edition , Tool Engineers Hand Book, Astme ,Mcgraw-Hill Book Company , Latest Edition , Robotics Control, Sensing, Vision And Intelligence, Fu.K.S.Gonzalz.R.C., And Lee C.S.G ,Mcgraw-Hill Book Company , 1987 , Audio And Video System – Principles, Maintenance And Troubleshooting , R.Gupta. ,Mcgraw-Hill Book Company ,Second Edition , Computer Organization, V.Carl Hamacher, Zvonko G.Vransic, Safgat G.Zaky ,Mcgraw-Hill Book Company , 5Th Edition , Elements Of Workshop Technology Volume I & Ii, Hajra Chowdry & Bhattacharaya,Media Promoters & Publishers , Latest Edition , Operation And Maintenance Of Electrical Equipment – Volume I & Ii, B.V.S.Rao ,Media Promoters & Publishers , 1St Edition, 1St Reprint 2011 , Elements Of Workshop Technology- Vol. I & Ii,Hajra Choudry & Battacharya ,Media Promoters & Publishers , Latest Edition , Hydraulic Machines, Jagadishlal, ,Metropolitan Book Company New Delhi , Latest Edition , Fluid Mechanics And Hydraulic Machines, Dr. Jagadish Lal ,Metropolitan Book Company New Delhi , Latest Edition , Mechanical Measurements &Control, D.S.Kumar ,Metropolitan Book Company New Delhi , Latest Edition , Introducing Microsoft .Net, David S.Platt ,Microsoft Press , 3Rd Edition , Computer Organization And Design, David A. Patterson And John L. Hennessey ,Morgan Kauffman / Elsevier , 5Th Edition , Complete Knowledge In C, Sukhendu Dey, Debobrata Dutta ,Narosa Publishing House, New Delhi , Reprint 2013 Or Latest Reprint , Software Testing, K.Mustafa And R.A.Khan ,Narosa Publishing House, New Delhi , Reprint 2009 , Software Quality, R.A. Khan, K.Mustafa And Si ,Narosa Publishing House, New Delhi , Reprint 2008 , Building Materials, S.K.Dugga ,New Age International (P) Ltd , 2003 , Reinforced Concrete Design, N Krishnaraju ,New Age International (P) Ltd , Latest Edition , Design Of R C C And Structural Elements ( Rcc Vol I), S S Bhavikatti, ,New Age International (P) Ltd , Latest Edition , G I S Basics, Shahab Fazal ,New Age International (P) Ltd , Latest Edition , Irrigation And Water Resources Engineering, G.L.Asawa ,New Age International (P) Ltd , Latest Edition , Basic Geotechnical Earthquake Engineering,,New Age International (P) Ltd , Latest Edition , Maintenance Of Buildings, A C Panchdhar ,New Age International (P) Ltd , Latest Edition , Engineeringdrawing And Graphics + Autoca, K.Venugopal, ,New Age International (P) Ltd , Latest Edition , Control Of Machines, S.K Bhattacharya ,New Age International (P) Ltd , Second Edition- Reprint 2010 , Quality Manageme, Narayana.V And Sreeniva N.S ,New Age International (P) Ltd , 1996 , Cad/Cam/Cim, R.Radhakrishnan, S.Subramanian ,New Age International (P) Ltd , Latest Edition , Electrical Power System, Clwadhawa ,New Age International (P) Ltd , Fourth Edition, 2009 , Hvdc Power Transmission System & Technology, Kr. Padiyar ,New Age International (P) Ltd , Reprint 2005 , Digital Protection – Protective Relaying From Electromechanical To Microprocessor, Lp Singh ,New Age International (P) Ltd , Second Edition 1997 , Electrical Design Estimating And Costing, K.B.Raina& S.K.Battacharya ,New Age International (P) Ltd , Reprint - 2011 , Control Of Electrical Machines., S.K. Bhattacharya ,New Age International (P) Ltd , Latest Edition , Power Electronics, Mohammed H.Rashid ,New Age International (P) Ltd , Third Edition,2004 , Programming In C, D.Ravichandran ,New Age International (P) Ltd , 1St Edition 1996, Latest Reprint , Linear Integrated Circuits, D.Roychoudhury & Shail.B. Jain ,New Age International (P) Ltd , 2Nd Edition, 2004. , Modern Television Practice– Transmission, Reception, Applications, R.R.Gulati,New Age International (P) Ltd , 5Th Edition , Monochrome & Color Tv , R.R.Gulati ,New Age International (P) Ltd , Latest Edition , Computer Fundamentals Architecture And Organization, B. Ram ,New Age International (P) Ltd , 5Th Edition , Principles Of Data Structures Using C And C++, Vinu V.Das ,New Age International (P) Ltd , Latest Reprint , Practical Scada For Industry, David Bailey Edwin Wright ,Newness , Latest Edition , Programmable Logic Controllers, W. Bolton ,Newness , Latest Edition , Practical C Programming, Steve Oualline ,O’Reilly , 3Rd Edition , Programming Php, Rasmus Lerdorf And Kevin Tatroe ,O’Reilly Publications , 3Rd Edition , Java, A Beginners Guide, Herbert Schildt ,Oracle Press , 6Th Edition , Pc Hardware In A Nutshell, Robert Bruce Thompson. ,Oreilly Media , Third Indian Reprint 2008. , Principles Of Electrical Machine Design, S.K.Sen ,Oxford & Ibh , Latest Edition , Principles Of Gis For Land Resources Assessment, Burrough P A ,Oxford Publication , Latest Edition , Programming In C, Reema Thereja ,Oxford University Press , 2Nd Edition , Digital Electronics, G.K.Kharate ,Oxford University Press , 2010 , Software Engineering Concepts And Application, Subhasjit Dattun ,Oxford University Press , 2010 , Software Engineering Fundamentals, Ali Behforooz And Fredick J Hudson ,Oxford University Press , 2005 , Reinforced Cement Concrete, Mallick And Rangasamy ,Oxford & Ibh , Latest Edition , Digital Communications Fundamentals And Applications, Bernard Sklar & Pabitra Kumar Ray ,Pearson Education , Latest Edition , Advanced Surveying, Sathesh Gopi, R.Sathikumar & N.Madhu ,Pearson Education , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C , Mazidi,Mazidi And D.Mackinlay,,Pearson Education , Latest Edition , Programmable Logic Controllers – Programming Methods And Applications, John R Hackworth And Fredrick D.Hackworth ,Pearson Education , Latest Edition , Principles Of Wireless Networks– A Unified Approach, Kaveh Pahlavan And Prashant Krishnamoorthy ,Pearson Education , 2002 , Electronic Communications Systems - Fundamentals Through Advanced, Wayne Tomasi ,Pearson Education , Fifth Edition , Digital Design, M.Morris Mano Michael D Ciletti ,Pearson Education , Latest Edition , 8051 Microcontrollers, Mazidi And D.Mackinlay ,Pearson Education , Latest Edition , Principles Of Wireless Networks – A Unified Approach, Kaveh Pahlavan And Prashant Krishnamurty ,Pearson Education , Latest Edition , Wireless Communications Principles And Practice, Theodore S. Rappaport ,Pearson Education , Latest Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Second Edition , Mobile Cellular Communication, Gottapu Sasibhushana Rao ,Pearson Education , Latest Edition , Operating System, Internal And Design Principles, William Stallings ,Pearson Education , 9Th Edition , Operating Systems, Deitel And Deitel ,Pearson Education , 3Rd Edition , Computer Organization And Architecture Designing For Performance, William Stallings ,Pearson Education , 10Thedition , Network Security Essentials, William Stallings ,Pearson Education , 5Th Edition , Cryptography And Network Security, William Stallings ,Pearson Education , 6Th Edition , Computer Networks, Andrew S.Tanenbaum ,Pearson Education , 5Th Edition , Web Development And Design Foundations With Html5, Terry Felke-Morris ,Pearson Education , 8Th Edition , Software Engineering, Ian Sommerville ,Pearson Education , Sixth Edition , Software Testing Principles And Practices, Srnivasan Desikan, Gopalswamy Ramesh ,Pearson Education , First Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Latest Edition , Fundamental Of Multimedia, Ze- Nian Li And M.S.Drew. ,Pearson Education , 2Nd Edition , Multimedia Computing, Communication And Applications, Ralf Steinmetz And Klara Nahrstedt ,Pearson Education , Latest Reprint , Multimedia Systems, John F. Koegel Buford ,Pearson Education , Latest Reprint , Total Quality Management, Date H.Besterfiled ,Pearson Education Asia. , Latest Edition , Automation, Production Systems, And Computer-Integrated Manufacturing, Mikell P. Groover ,Pearson Education Asia. , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C, Mazidi,Mazidi And D.Mackinlay ,Pearson Education Low Price Edition. , Latest Edition , Design Of Steel Structures, K.S.Sai Ram ,Pearson-Porling Kindersley Pvt Ltd , Latest Edition , 8051 Microcontroller, Kenneth Ayala ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Plc And Industrial Automation An Introduction, Madhuchhanda Mitraand Samarjit Sen Gupta ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Industrial Energy Conservation-, D. A. Ray- ,Pergaman Press , Latest Edition , Electronics Devices And Circuit Theory, Boyestad & Nashelsky ,Phi , Latest Edition , Electronic Devices & Circuits An Introduction, Allen Mottershed,Phi , Latest Edition , Computer Graphics Multimedia And Animation,, Malay K. Pakhira ,Phi , 2Nd Edition , Principles Of Digital Electronics, K.Meena ,Phi , 2011 , Operational Amplifiers And Linear Integrated Circuits, Robert F. Coughlin Frederick F. Driscoll ,Phi , 1992 , Op. Amp & Linear Integrated Circuits, Ramakant. A. Gayakwad ,Phi , 1992 , Digital Electronics- An Introduction To Theory And Practice, William H.Gothmann ,Phi , 1998 , Transducers And Instrumentation, Dvs Murty ,Phi , 2009 , Measurement And Instrumentation, Arun. K ,Phi , 2010 , Sensor And Transducers, D. Patranabis ,Phi , 2011 , Elements Of Engineering Mechanics, Sanchayan Mukherjee ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass, ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Limit State Design Of Reinforced Concrete, P C Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, .M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Principles Of Environmental Science And Engineering,, P.Venugopala Rao ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Irrigation And Water Power Engineering, Madan Mohan Das&Mimi Das Saikia ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Buildingconstruction, P.C.Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Energy Engineering And Management, Amlan Chakrabarti ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Power Electronics, M.S.Jamil Asghar ,Phi Learning Pvt. Ltd., New Delhi. , Eastern Economy Edition, 2010 , Principles Of Digital Electronics, K.Meena ,Phi Learning Pvt. Ltd., New Delhi. , 2009 , Operating System, Principles & Design, Pabitra Pal Chaudhuri ,Phi Learning Pvt. Ltd., New Delhi. , 1St Edition , Computer Organization & Architecture, Rajaraman ,Phi Learning Pvt. Ltd., New Delhi. , Latest Reprint , Fundamentals Of Software Engineering, Rajib Mall ,Phi Learning Pvt. Ltd., New Delhi. , 28Th Printing – August 2011 , A Textbook On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Electronics Devices And Circuit Theory , Boyestad & Nashelsky ,Phi Publication, New Delhi , 2009 , Electronicsdevices And Circuits, Allen Mottershed ,Phi Publication, New Delhi , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D.Helfrick And Willam David Cooper ,Phi Publication, New Delhi , 1996 , A Text Book On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Power Electronics, M.H.Rashid ,Phi Publication, New Delhi , 3Rd Edition-2005 , Industrial Electronics And Control, Biswanath Paul ,Phi Publication, New Delhi , 2Nd Edition -2010 , Programmable Logic Controllers, Frank D.Petruzela ,Phi Publication, New Delhi , 2Nd Edition- 1998 , Programmable Logic Controllers Principles And Applications, John W. Webb. Ronald A. Reis ,Phi Publication, New Delhi , Latest Edition , Networks Lines And Fields, John D.Ryder ,Phi Publication, New Delhi , Latest Edition , Electronic Communication, Dennis Roddy And John Colen ,Phi Publication, New Delhi , Latest Edition , Principles Of Digital Electronics, K.Meena ,Phi Publication, New Delhi , Latest Edition , Digital Electronics, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Digital Electronics – An Introduction To Theory And Practice, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Ramakant A Gayakwad ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Robert F.Coughlin And Frederick F.Driscoll ,Phi Publication, New Delhi , Latest Edition , Microcontrollers, Principles And Applications, Ajit Pal ,Phi Publication, New Delhi , Latest Edition , Vhdl Primer, Bhasker J ,Phi Publication, New Delhi , Latest Edition , Digital Electronics With Pld Integration, Nigel P. Cook ,Phi Publication, New Delhi , Latest Edition , Digital Logic Simulation And Cpld Programming With Vhdl, Steve Waterman ,Phi Publication, New Delhi , Latest Edition , Data And Computer Communications, William Stallings ,Phi Publication, New Delhi , Latest Edition , Computer Networks , Andrew S.Tanenbaum ,Phi Publication, New Delhi , Latest Edition , Wireless Digital Communications, Kamilo Feher ,Phi Publication, New Delhi , Latest Edition , Wireless Communications And Networks, William Stallings ,Phi Publication, New Delhi , Latest Edition , Irrigation Water Management, Dilip Kumar Majumdar ,Phi Publication, New Delhi , Latest Edition , Multimedia Systems Design., Prabhat K.Andleigh, Kiran Thakra ,Phi Publication, New Delhi , Latest Edition , Performance And Design Of Ac Machines, M.G.Say ,Pitman Publishing Ltd , Latest Edition , Principles Of Management, M.Govindarajan And S.Natarajan ,Prentice-Hall Of India (P) Ltd , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D. Helfrick William David Cooper ,Prentice-Hall Of India (P) Ltd , Latest Edition , Building Materials, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Building Constructions, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Geographic Information Systems, Lo & Yeung (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Geographic Information Systems & Environmental Modelling, Clarke Parks & Crane (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Foundation Design, Wayne C.Teng ,Prentice-Hall Of India (P) Ltd , Latest Edition , Operations Research, H.A.Taha ,Prentice-Hall Of India (P) Ltd , Latest Edition , Total Quality Management – An Introductory Text, Paul James ,Prentice-Hall Of India (P) Ltd , Latest Edition , Electronic Device And Circuits- An Introduction, Allen Mottershed,Prentice-Hall Of India (P) Ltd , Latest Edition , Techniques Of Press Working Sheet Metal, Donald F. Eary. & Edward A. Reed ,Prentice-Hall Of India (P) Ltd , Latest Edition , Essentials Of Management, Joseph L.Massie ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Elements Of Electrical Engineering, Maria Louis ,Prentice-Hall Of India (P) Ltd , Latest Edition , Digital Electronics, William H.Gothmann ,Prentice-Hall Of India (P) Ltd , Latest Edition , Programmable Logic Controllers – Principle And Applications, John W. Webb ,Prentice-Hall Of India (P) Ltd , Latest Edition , Computer Networks, Andrew S.Tanenbaum ,Prentice-Hall Of India (P) Ltd , 2002 , Data And Computer Communications, William Stallings ,Prentice-Hall Of India (P) Ltd , Eighth Edition 2007 , Computer System Architecture, M.Morris Mano ,Prentice-Hall Of India (P) Ltd , 3Rd Edition , Data Structures A Programming Approach With C, Dharmender Singh Kushwaha And Arun Kumar Misra ,Prentice-Hall Of India (P) Ltd , 2012, Latest Reprint , Classic Data Structures, Debasis Samanta ,Prentice-Hall Of India (P) Ltd , 2Nd Edition , The Internet, Douglas E.Comer ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Introduction To Biomedical Instrumentation, Mandeep Singh,Prentice-Hall Of India (P) Ltd , Latest Edition , Iso 9001, Brain Rethry, Brain Rethry ,Productivity And Quality Publishing Pvt. Ltd. , 1993 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 2008 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 23Rd Edition , Limit State Theory And Design Of Reinforced Concrete, S.R.Karve And V.L.Shah ,Puna Vidyarthi Griha, Prakashan , 5Th Edition , A Course In Electrical And Electronics Measurements And Instrumentation, A.K. Sawhney ,Puneet Sawhney Dhanpat Rai & Co (P) Ltd. , Latest Edition , Upgrading And Repairing Laptops, Scott Mueller ,Que Publication , Latest Edition , A Text Book Of Fluid Mechanics And Hydraulic Machines,By, R. K Rajput And S.Chand ,R. K Rajput And S.Chand & Co, New Delhi , Latest Edition , Training Manual On Iso 9001 : 2000 & Tqm, Girdhar J.Gyani ,Raj Publishing House , Latest Edition , Electrical Machine Design, A.Naoor Kani ,Rba Publications , Latest Edition , A Course In Electrical Engineering , B.L.Theraja ,S.Chand & Company Ltd, New Delhi ,Reprint 2006 , A Text Book Of Transportation Engineering, S P Chandola ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R.S.Khurmi ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R. S. Khurmi, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Production Technology , P. C. Sharma ,S.Chand & Company Ltd, New Delhi ,Edn. X , Thermal Engineerin, , R.S. Khurmi, J.K Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , A Text Book Of Hydraulics, Fluid Mechanics And Hydraulic Machines,R.S. Khurmi ,S.Chand & Company Ltd, New Delhi ,Edn.18 , Thermal Engineering, R.S. Khurmi And J.K. Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , The Automobile, Harbans Singh Reyat, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Non Conventional Energy Sources And Utilisation , R.K. Rajput - S.Chand ,S.Chand & Company Ltd, New Delhi , 2012 , A Text Book Of Electrical Technology Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , A Text Book Of Electrical Technology -Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , Principles Of Power System, V.K.Metha ,S.Chand & Company Ltd, New Delhi , 4Th Edition Reprint 2007 , Electronic Measurements And Instrumentation, R.K.Rajput ,S.Chand & Company Ltd, New Delhi , 3Rd Edition 2009 , Computer Concepts And C, Dr.S.S.Khandare ,S.Chand & Company Ltd, New Delhi , 1St Edition 2010, Latest Reprint , Electrical Technology Vol I And Ii, B.L.Theraja ,S.Chand & Company Ltd, New Delhi , Mutiple Colour Edition,2012 , Principles Of Electronics, V.K.Mehta ,S.Chand & Company Ltd, New Delhi , Second Edition , Electronics And Instrumentation, Dr.S.K.Battachariya Dr. Renu Vig ,S.K. Kataria & Sons, New Delhi , Latest Edition , Principles Of Electrical Machine Design, R.K.Agarwal ,S.K. Kataria & Sons, New Delhi , Latest Edition , Environmental Engineering And Management, Dr.Suresh K.Dhameja- ,S.K. Kataria & Sons, New Delhi , Latest Edition , Soil Mechanics & Foundation Engineering, V N S Murthy ,Sai Kripa Technical Consultants , Latest Edition , Digital Communications, Dr.K.N.Hari Bhat Dr.D.Ganesh Rao ,Sanguine Technical Publisher , Latest Edition , Energy Resource Management, Kirpal Singh Jogi- Sarup And Sons ,Sarup And Sons , Latest Edition , A Course In Electrical And Electronic Measurement And Instrumentation, Umesh Sinha ,Satya Prakashan, New Delhi , Latest Edition , Electrical And Electronics Measurements And Instrumentation, Umesh Sinha ,Satyaprakashan Tech , 1992 , Theory And Problems Of Machine Design, Holowenko, Laughlin ,Schaum’S Outline Series. , Latest Edition , Data Structures With C, Seymour Lipschutz ,Schaums Outlines, Tmh , Latest Reprint , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication , Latest Edition , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication, Chennai. , Latest Edition , Limit State Design Of Concrete Structures, Dr.S.Ramachandra ,Scientific Publishers , Latest Edition , Murach’S Mysql, Joel Murach ,Shroff / Murach , 2012, Latest Reprint , Fundamentals Of Tool Design, Dr.John G.Nee ,Society Of Manufacturing Engineers. , Latest Edition , Electrical Machine Design, C.Eswarlal ,Sonaversity , Latest Edition , A Concise Introduction To Software Engineering, Pankaj Jalote ,Springer, Latest Edition , Design Of Electrical Machine, Mittle V.N ,Standard Book – House , Latest Edition , Fluid Mechanics, P.N. Modi & S.M. Sethi ,Standard Publishers & Distributors, New Delhi , Latest Edition , Water Supply And Sanitary Engineering Vol I & Ii, Gurcharan Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Hydraulics, Fluid Mechanics And Hydraulics Machines, K.R. Arora ,Standard Publishers & Distributors, New Delhi , Latest Edition , Automobile Engineering Vol- 1, Vol – 2,Kirpal Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Learning Material Development Project,,Taramani, Chennai, Cd Programme On Gps And Gis , Latest Edition , Principles Of Transportation & Highway Engineering, G V Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, N.N. Basak ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, A.Kamala,D.L.Kanthrao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Engineering Hydrology, K.Subramanya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Production And Operations Management, S.N. Chary ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Essentials Of Management, Koontz &Weihrich ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Business Correspondence & Report Writing, R.C. Sharma And K.Mohan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , How To Prepare For Group Discussion & Interview (With Audio Cassette), Prasad ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Construction Management And Planning, Sengupta.B, &H.Guha ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Applications In Construction, Boyd.C. & Paulson Jr ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Fluid Mechanics And Machinery, B C S Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Geotechnical Earthquakes Engineering Hand Book,,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials, S.S.Rattan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials,B K Sarkar ,Tata Mcgraw-Hill Publishing Company Ltd , I Edition, 2003 , Production Technology,,Tata Mcgraw-Hill Publishing Company Ltd ,Edn. 18. 2001 , Autocad With Applications, Sham Tickoo,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynami, Pk Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , Production Technology, Hmt, ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 18 , Manufacturing Process, Myro N Begman ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 5 , Production Processes, Nitttr, ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Circuits & System- Analog And Digital , Y.N.Bapat ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynamics, P.K. Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Ndedition , Quality Management, Howard Cuitlow ,Tata Mcgraw-Hill Publishing Company Ltd , 1998 , Quality Planning And Analysis, Juran J.M And Frank M.Gryna Jr. ,Tata Mcgraw-Hill Publishing Company Ltd , 1982 , Tool Design, Donaldson ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Non-Conventional Energy Resources ,B.H.Khan ,Tata Mcgraw-Hill Publishing Company Ltd ,2Nd Edn, 2009. , Cad/Cam Principles And Applications, Dr.P.N.Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cad/Cam, Ibrahim Zeid ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Measurement Systems, E. O. Doebelin ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Robotics And Image Processing, Janakiraman.P.A ,Tata Mcgraw-Hill Publishing Company Ltd , 1995 , Circuits And Networks Analysis And Synthesis., A. Sudhakar Shyammohan S Palli ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electric Circuits, Mahamood Nahvi Joseph A Edminister ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Nagarath ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Bhattacharya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Jacob Millman And Halkias ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Optical Fiber Communication, Gerdkeise ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Instrumentation, Hs Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P.Jains ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles & Applications, Albert Paul Malvino & Donaldp.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Introduction To Microprocessor, Aditya P Mathur ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Power System Protection And Switchgear, B Ram & Dn Viswakarma ,Tata Mcgraw-Hill Publishing Company Ltd , Reprint 2000 , Programmable Logic Controllers, Frank D.Petruzella ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Power Distribution System, As Pabla ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Utilization Of Electric Power, Nv Suryanarayana ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Troubleshooting, Maintaining And Repairing Pcs, Stephen J Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , 2006 , Computer Networks, Achyut Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices And Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2016 , Electronic Principles , Malvino ,Tata Mcgraw-Hill Publishing Company Ltd , 2010 , Electronicsdevices And Circuits, Jacobmillmanandhalkias ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2010 , Electronic Instrumentation, Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Programming In Ansi C , E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Programming And Problem Solving Using C, Isrd Group, Lucknow ,Tata Mcgraw-Hill Publishing Company Ltd , 2008 , Electronic Communication Systems, Kennedy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, Arvind M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Communication Electronics Principles And Application , Louis E Frenzel ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles And Applications, Albert Paul Malvino & Donald P.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Linear Integrated Circuits, Salivahanan & V.S.Kanchana Baskaran ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Communication Systems, Kennedy – Davis ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Communication, P.Ramakrishna Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Principles Of Communications System, Taub &Schilling ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Tata Mcgraw-Hill Publishing Company Ltd , Second Edition 2010 , Troubleshooting, Maintaining And Repairing Pcs, Stephen J.Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , Fifth Edition , Ibm Pc And Clones, B.Govindrajalu ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, By A.M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Color Tv, Theory And Practice, S.P.Bali ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P. Jain ,Tata Mcgraw-Hill Publishing Company Ltd , Third Reprint 2010 , Basic Electricall Engineering, V.N.Mittle ,Tata Mcgraw-Hill Publishing Company Ltd , First Edition , Basic Electrical And Electronics Engineering, R,Muthusubramanian R.Salivajanan ,Tata Mcgraw-Hill Publishing Company Ltd , Seventh Reprint 2011 , Computer Architecture And Organization, John P. Hayes ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Data Communication And Networking, Behrouz A.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Computer Communications And Networks, Achyuts.Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cryptography And Network Security, Behrouza.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Programming With Java, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Data Structures And Algorithms, G.A.Vijayalakshm I Pai ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Reprint Or Latest Reprint , Data Structures Using C, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Programming In C#, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Applications Of .Net Technology, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , 1St Edition Or Latest Reprint , Cloud Computing A Practical Approach 2008 Edition, Cloud Computing A Practical Approach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Software Engineering, Stephen Schach ,Tata Mcgraw-Hill Publishing Company Ltd , Eight Reprint 2011 , Mobile Computing, Asoke K Talukder,Hasan Ahmed, Roopa R Yavagal ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Multimedia: Making It Work., Tay Vaughan ,Tata Mcgraw-Hill Publishing Company Ltd , 8Th Edition , Multimedia Communication Systems: Techniques, Standards, And Networks, K.R. Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Principles Of Multimedia, Ranjan Parekh ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , The Complete Reference Linux, Richard Peterson ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Edition , A Text Book Of Engineering Drawing,R.B. Gupta ,Technical India Publications, New Delhi , Latest Edition , Digital Communication, Dr. J.S.Chitode ,Technical Publications – Pune , Latest Edition , Introduction To Plc, Gary Dunning ,Thomson Del Mar Learning , 3Rd Edition , Data Structures Using C – 1000 Problems And Solutions, Sudipta Mukherjee ,Tmgh, New Delhi , 2Nd Reprint Or Latest Reprint , Industrial & Power Electronics, Harish C.Rai ,Umesh Publications , 2017 , Construction Engineering & Management, Seetharaman. S ,Umesh Publications , Latest Edition , Introduction To Earthquake Engineering,,University Of Tokyo Press , Latest Edition , Digital Electronics And Logic Design, Jaydeep Chakravarthy ,University Press, Hyderabad , First Edition2012 , Introduction To Data Structures Using C, Venkatesh N.Baitipuli ,University Science Press, Chennai , 1St Edition, 2009 Or Latest Reprint , Software Engineering, Rohit Khurana ,Vikas Publishing Ltd , Second Edition , Organizational Behaviours, S.Chandran ,Vikas Publishing Ltd , Latest Edition , Operating Systems, Rohit Khurana ,Vikas Publishing Ltd , 2Nd Edition , Workshop Technology, Waj Chapman ,Vima Books Pvt. Ltd New Delhi , Latest Edition , Energy Auditing In Electrical Utilities, Rajiv Shankar ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Workshop Tech Vol I,Ii, Iii, Waj. Chapman ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Wireless And Mobile Network Architectures, Yi-Binglin, Imrich Chlamtac ,Wiley , Latest Edition , Wireless Networks, P. Nicopolitidis ,Wiley , Latest Edition , Operating System Concepts, Abraham Siberschatz, Galvin, Gagne ,Wiley , 9Th Edition , Microprocessor Architecture Programming And Application, Ramesh S. Gaonkar, ,Wiley Eastern Ltd , Latest Edition , Introduction To System Design Using Ic, B.S. Sonde ,Wiley Eastern Ltd , Latest Edition , Fundamentals Of Acoustics, Kingsler And Frey,Wiley Eastern Ltd , Latest Edition , Beginning Android 4 Application Development, Wei-Meng Lee ,Wiley India Edition , Latest Edition , Power Electronics, Mohan, Undeland, Robbins. ,Wiley India Edition. , Media Enhanced Third Edition , Web Programming, Chris Bates ,Wiley India, New Delhi, 3Rd Edition , Cloud Security: A Comprehensive Guide To Secure Cloud Computing, Ronald L. Krutz Russell Dean Vines ,Wiley Publishing, Inc , Latest Edition , Cloud Computing Bible, Barrie Sosinsky ,Wiley Publishing, Inc. , Latest Edition , Total Quality Management For Engineers, Zeiri ,Wood Head Publishers , 1991 , Mechanics Of Structures- Vol 1, S.B.Junnarkar , , Latest Edition , I S 2185 Part I & Ii, Ernest O. Doebelin , , Latest Edition , Pwd & Cpwd Specifications, D.V.S.Murty , , Latest Edition , National Building Code,, , Nbc-2012 , Tamilnadu District Municipal Building Rules And By-Laws,, , Latest Edition , Civil Engineering Drawing And House Planning, B.P. Verma , , Latest Edition , Building Planning And Drawings, Dr N. Kumaraswamy And A. Kameswara Rao , , Latest Edition , Building Planning And Construction, G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , , Latest Edition , Civil Engineering Drawing, S.C.Rangwala , , Latest Edition , A Guide To Civil Engineering Drawing, V.R.Thothathri , , Latest Edition , Theory Of Structures, S. Ramamrutham , , Latest Edition , Analysis Of Structures, V.N. Vazirani & M.M. Ratwani , , Latest Edition , Elementary Theory Of Structures, R.L. Jindal , , Latest Edition , Strength Of Materials, Fv. Warnock , , Latest Edition , Estimating & Costing, Bridie , , Latest Edition , Indian Standard Code Of Practice, Is:1200,, , Latest Edition , I S 456-2000 ; I S 875-1987; I S 800 -2007,, , Latest Edition , Explanatory Hand Book Sp24, Design Aid Sp 16,Detailing Of Reinforcement,Sp 34,, , Latest Edition , Concrete Technology , M.S. Shetty , , Latest Edition , Fire Resistant Construction – Building Construction, S.P.Arora And S.P.Bindra , , Second Edition , Earth Quake Proof , Dr.Janardhanjha And Prof.Suresh Kumar , , Latest Edition , Sinha Is Code Of Practice For Earth Quake , Is Code Of Practice For Fire Resistance, Is Code Of Practice For Pre Stressing,, , Latest Edition , Pile Foundation, Rd Chellis, Mis , , Latest Edition , Construction And Foundation Engineering, Sinha & Janatha Shau , , Latest Edition , Principle Fine Safety Standards For Building Construction, M.Ya Roytman , , Second Edition , Remote Sensing And Geographical Information Systems, Anji Reddy.M. (1998) , , Latest Edition , Analysis And Design Of Substructures (Lsd) – Second Edition 2010, Swami Saran , , Latest Edition , Civil Engineering Drawing, M Chakrabort , , Latest Edition , Civil Engineering Drawing, Gurucharan Singh & Subhash Chandar Sharma , , Latest Edition , Civil Engineering Drawing Manual, S Chand & Company (Pvt) Ltd. , , Latest Edition , Production Systems: Planning, Analysis And Control, J.L.Riggs, 3Rd Ed , , Latest Edition , Productions And Operations Management, A.Muhlemann, J.Oakland And K.Lockyer, Macmillan , , Latest Edition , Operations Research, J.K.Sharma, Macmillan , , Latest Edition , Spoken English – A Self-Learning Guide To Conversation Practice (With Cassette),, , Latest Edition , Quality Control And Applications, Housen&Ghose , , Latest Edition , Industrial Engineering Management, O.P. Khanna , , Latest Edition , Steel Structures, Dr.Subramaniam , , Latest Edition , Town Planning, S.C. Rangwala , , Latest Edition , Town Planning, K.S.Rangwala And P.S.Rangwala , , Latest Edition , Remote Sensing Methods And Application, Michael Hord, R , , Latest Edition , National Building Code Of India- Part-Iii.(2005),, , Latest Edition , Municipal And Panchayat Bye-Laws, Cmda Rules And Corporation Bye-Laws.,, , Latest Edition , Urban And Regional Planning, Ka. Ramegowda , , Latest Edition , Earthquake Resistant Design Of Structures, Pankaj Agarwal And Manish Shrikhande , , Latest Edition , Guidelines For Earthquake Resistant Non Engineered Construction, The Associated Cement Companies Ltd , , Latest Edition , Criteria For Earthquake Resistant Design Of Structures - General Provisions And Buildings, Is: 1893 ( Part 1 ) - 2002,, , Latest Edition , Code Of Practice For Ductile Detailing Of Rc Structures Subjected To Seismic Forces, Is:13920-1993.,, , Latest Edition , Earthquake Tips, C.V.R.Murty, , , Latest Edition , Indian Standard Code Of Practice, Is:1200.,, , Latest Edition , Estimating And Costing, Vazirani & Chandolu , , Latest Edition , Geometrical And Machine Drawing, N.D. Bhatt, Anand , , Latest Edition , Hydraulics, Andrew Parr , , Latest Edition , Fundamentals Of Pneumatic Control Engineering, Festo Manual , , Latest Edition , Electrical Technology, Hughes, , 8Th Edition , Machine Design Bandari,,, , Latest Edition , Industrial Engineering & Management, O.P Khanna , , Latest Edition , Industrial Engineering & Production Management, Martand Telsang , , Latest Edition , Production Engineering , P.C.Shrma. , , Latest Edition , Production And Costing, Gbs Narang And V.Kumar , , Latest Edition , Mechanical Estimating And Costing , Banga & Sharma. , , Latest Edition , Quality Auditing, D.Mills, Chapman And Hall , , 1993 , Refrigeration And Air Conditioning, V.K. Jain, , , Latest Edition , Industrial Refrigeration Hand Book, Wilbert F. Steocker , , Latest Edition , A Course In Refrigeration And Air Conditioning , Domkundwar , , Latest Edition , Principles Of Refrigeration, Dossat, , Latest Edition , Electronic Principles , Malvino , , Latest Edition , Microcontrollers, Principles And Applications – Ajit Pal – Phi Ltd., - 2011.,, , Latest Edition , Biomedical Instrumentation ,Anuradha Publications, Chennai, Dr.M. Arumugam , , Latest Edition , Bio Medical Instrumentation And Measurements, Ii Edition., Leslie Cromwell –Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering., Jacobson And Webstar , , Latest Edition , Hand Book Of Bio –Medical Instrumentation., R.S .Khandpur , , Latest Edition , Medical Electronics, Kumara Doss , , Latest Edition , Introduction To Medical Electronics, B.R. Klin , , Latest Edition , Introduction To Biomedical Instrumentation , Mandeep Singh Printice Hall India 2010. , , Latest Edition , Digital Communications, John G.Prokais , , 2011 , Biomedical Instrumentation And Measurements, Leslie Cromwell, Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering, Jacobson And Webstar , , Latest Edition , Hand Book Of Bio–Medical Instrumentation., R.S .Khandpur , , Latest Edition , Engineering Mathematics - Dr.M.K.Venkatraman, National Publishing Co, Chennai 2. , Engineering Mathematics – Dr.P.Kandasamy & Others, S.Chand & Co Ltd, New Delhi , Physics, Resnick And Haliday–Wisley Toppan Publishers–England , Engineering Physics–B.L.Theraja–S. Chand Publishers , A Text Book Of Sound–R.L. Saighal & H.R. Sarna–S.Chand & Co. , Mechanics–Narayana Kurup–S. Chand Publishers. , Fundamentals Of Physics – Brijlal And Subramaniam. , Fundamentals Of Electricity – D.N. Vasudeva – S. Chand & Co , Non-Conventional Energy Sources – G.D. Rai.- Khanna Publishers , Text Book Of Remote Sensing And Geographical Information Systems – M. Anji Reddy Bs Publications. , Engineering Chemistry – Jain & Jain – Dhanpat Rai & Sons. , A Text Book Of Engineering Chemistry – S.S. Dara – S. Chand Publication. , A Text Book Of Environmental Chemistry And Pollution Control – S.S. Dara – S. Chand Publication. , Engineering Chemistry – Uppal – Khanna Publishers. , Environmental Chemistry – V P Kudesia – Pragati Publishers. , Chemistry Of Engineering Material – C.V. Agarwal, Andranaidu C. Parameswara Moorthy – B.S. Publications. , A Text Book Of Inorganic Chemistry – P.L. Soni – S. Chand Publication. , Rain Water Harvesting – Hand Book – Chennai Metro Water. , Bhatt N.D. And Panchal V.M., “Engineering Drawing”, Charotar Publishing House, 50Th Edition, 2010. , Gill P.S., “Engineering Drawing”, S.K.Kataria & Sons. , Gopalakrishnan.K.R., Engineering Drawing, (Vol.I And Vol.Ii), Dhanalakshmi Publishers, Edition 2 , Venugopal.K, Sreekanjana G, “Engineering Graphics” New Age International Publishers. , K V Nataraajan “A Text Book Of Engineering Drawing” , Besant Agrawal, C M Agrawal “Engineering Drawing”, Tata Mcgraw Hill Education Private Limited. , Barkinson & Sinha, First Year Engineering Drawing, Pitman Publishers. , Communication Skill, Sanjay Kumar Pushp Lata, Oxford University Press , Communication Skill, , Gph Publication , English Communication Teory And Practical, Manoj Kumar Garg, Scholar Tech Press , Little Redbook - Grammar Made Easy, Terry O Brien
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
TenderDetail
Loading tenders