View Bid Results For Data Leakage Tenders

We found 324 Bid Results related to data leakage tenders. You can find Contractor details who won data leakage tenders along with contract details in Bid awards announcements section.

Filters
Stage
244
54
26
Tender Publishing Platform
34
290
State / UT
28
71
59
36
29
20
16
14
12
8
7
6
5
5
4
4
3
3
3
3
3
2
2
2
2
2
1
1
1
Contract Value
130
33
94
67
Publish Date
1
0
0
0
0
Sector
20
94
42
39
29
24
22
15
13
9
7
7
5
4
4
2
2
2
2
1
1
Ownership
6
177
59
50
36
1
1
Within keyword
Active filters:
Showing 1–7 of 324 tenders matching your filters
1.
Health and Family Welfare #11430568 Technical Bid
Tender for Pruchase Of Surgical And Sutures Items At Govt Hospital Bundi , Surgical And Sutures , Absorbable Gelatin Sponge Ip 66, Size 80(+-10) Mm X 50 Mm X 10 Mm Should Be Sterlized. , Asepto Syringe With Transparent Bulb Sterile, 60 Ml , Blood Administration Set / Blood Transfusion Set • Sharp And Easy Piercing Spike Suitable For Blood Bags And Standard Blood Containers • Transparent Cylindrical Drip Chamber With Filter.Filter Size Should Be 200+20 Micrometer. • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Transfusion Rate • Should Conform To Is 9824(Part 3):1996 , Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches • Made Of Natural Rubber Latex, Powdered, Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards) , Disposable Sterile Surgical Rubber Gloves Size 7 Inches • Made Of Natural Rubber Latex, Powdered,,Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 7 Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards) , Disposable Sterile Surgical Rubber Gloves Size 7½ Inches • Made Of Natural Rubber Latex, Powdered, Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 7 ½ Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards , Suction Catheter, Sterile. Size: Fg 5 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 6 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 8 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 10 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 12 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 14 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 16 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 18 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 20 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 22 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 3- 5 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 3- 5 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Infant Feeding Tube Size:10Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:8Fg, Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:5Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Sterile Disposable Perfusion Set With Airway And Needle (Adult Use) • For Gravity Feed Only • Sharp And Easy Piercing Spike With Air Vent • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Self Sealing Latex Bulb Which Will Also Act As An Port For Extra Medication • Efficient Roller Clamp To Control And Adjust The Fluid Rate • 21 G Needle • Should Conform To Is 12655 -4 Standard , Sterile Disposable Perfusion Set (Infusion Set) With Airway And Needle (Paediatric Use) • Burette Type Measured Volume Chamber Of 100 Ml • Drop Size Of Approx 60 Drops Per Ml • Injection Port,Latexfree, For Intermittent Medication. • Floating Auto Shut Off Valve (Latex Free) In Burette. • Soft And Kink Resistant Pvc Tubing. • Roller Controller For Flow Control • Tube Length 150 Cm • 23G Needle • Should Conform To Iso 8536-5 , Sterile Disposable Infusion Set With Microdrip (I.V.) • Microdrip Infusion Set With Drop Size Reduced To Approx 60 Drops Per Ml • Sharp And Easy Piercing Spike • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Fluid Rate • Should Conform To Is 12655 - 4 Standard , Insulin Syringe ( 40 Units) With (Fixed) 30 G Needle Shall Conform To Is 12227 , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 16G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. ) Size 18G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 20G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 22G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon/ Ptfe I.V. Cannula Without Port. Size 24G • Suitable For Paediatric & Neonatal Use • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Mucus Extractor Sterile • Clear Transparent Container • Antibacterial Filter • Soft, Kink Resistant Pvc Tubing • Tube Size 10 Fg; Length 40 Cm (Min.) • Capacity 25 Ml , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Adult) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Pediatrics) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Paper Adhesive Plaster 1 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Paper Adhesive Plaster 2 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Paper Adhesive Plaster 3 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Plaster Of Paris Bandages 15Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Plaster Of Paris Bandages 10Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 10 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 12 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 14 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 16 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 18 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Scalp Vein Set (Disposable): Size 18G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 20G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 22G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 24G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 2 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 5 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 10 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 20 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Surgical Blade Sterile, Size 11 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 15 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 22 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Sterile Disposable Spinal Needle For Single Use 22G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Sterile Disposable Spinal Needle For Single Use 25G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Urine Collecting Bag, Disposable 2000 Ml • Transparent Sheet • Kink Resistant Flexible Tubing Not Less Than 90 Cm In Length • Should Have Non-Return Valve • Top Drainage Outlet • Graduated Bag • Moulded Handle For Easy Handling , Double J Stent, Sterile, Both Ends Open - Size 4F, Length 16 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, Both Ends Open, Size 5F, Length 20 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, One End Closed - Size 4F, Length 16 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, One End Closed, Size 5F, Length 20 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Endotracheal Tube, Plain - Size 2.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 5.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain With Radio-Opaque Line, Sterile, Single Use - Size 6Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 6.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 8Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 8.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Cuffed - Size 4Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 4.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 6Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 6.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 9 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Tracheostomy Tube (Pvc), Plain, Sterile, Single Use - All Sizes • Soft Flexible Flange At For Easy Fixation • 15 Mm Connector At Terminal End Which Can Be Rotated In 360 Degree Direction • Non-Irritant • Radio-Opaque Line , Tracheostomy Tube (Pvc), Cuffed, Sterile, Single Use - All Sizes • Soft Flexible Flange At For Easy Fixation • 15 Mm Connector At Terminal End Which Can Be Rotated In 360 Degree Direction • Non-Irritant • Radio-Opaque Line • Balloon With Non Return Valve , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 24) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 28) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 32) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.5 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Sterilised Umbilical Cotton Tape Width 3 Mm, Length 75 Cm Should Conform To Schedule F(Iii) Of Drug And Cosmetic Act 1940 , Bone Wax Sterilised , Skin Graft Knife Blade (Sterile) (Disposable ) Skin Grafting Knife Blade (Sterile) Made Of Carbon Steel Or Stainless Steel Material 158 Mm Long Individually Wrapped In Wrapper Corrosion Inhibitor Paper In Single Packet,.In Packs Of 10. The Edge Must Be Sharp Enough To Cut The Skin In A Single Shave And Should Snugly Fit In The Handle Should Conform To Is 3759. 2. Skin Grafting Knife Handle (Watson Modification Of HumbyS Knife ) Stainless Steel, Ce Certified, In Which The Blade Specified In (A) Above Should Fit Snugly. Should Conform To 7980-1976. , K Wire, Length 375 Mm; 1Mm Length Of Wire Should Be Mentioned With Specification. Should Conform To Is 8261 , K Wire, Length 375 Mm;1.6Mm • Length Of Wire Should Be Mentioned With Specification. • Should Conform To Is 8261 , K Wire, Length 375 Mm; Size 1.8Mm • Length Of Wire Should Be Mentioned With Specification. •Should Conform To Is 8261 , Face Mask, Disposable • Should Be Manufactured From Non Woven Poly Prop Fabric • Should Be 3 Ply Construction • Should Have High Bacterial Filtration Efficiency • Should Be Heat Sealed To Keep 3 Layers Together • Standard Size 17.5 X9 Cm • Color Green/Blue • There Should Be A String Each At All Four Corners,Length Of String Should Be 40Cm • Nose Clip Should Be There • No Elastic Band. , Surgical Cap, Disposable (For Surgeons) • Should Be Manufactured From Non Woven Fabric. • Strip For Tying The Cap Stitched On The Back For Proper Grip On The Forhead. • Green Colour • Ultrasonically Stitched • Air Permeable/Breathable • Should Retain Skin And Hair Particle. • Strip For Tying The Cap , Surgical Cap, Disposable ( For Nurses) • Should Be Manufactured From Non Woven Fabric • Blue / Green Colour • Round Upon Wearing, With Elastic • Air Permeable / Breathable • Should Retain Skin And Hair Particles , Foldable Intra Ocular Lense With Injector (Size + 11 D To +17.5 D) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 11 D To +17.5 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Foldable Intra Ocular Lense With Injector (Size + 18 D To + 24 D) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic/Plate Haptics 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 18 D To + 24 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Foldable Intra Ocular Lense With Injector (Size + 24.5 D To + 28.5 D ) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 24.5 D To + 28.5 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 11 D To +17.5 D) • 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Biconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 11 D To +17.5 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 18 D To + 24 D) • 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Biconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 18 D To + 24 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 24.5 D To + 28.5 D ) 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Bioconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 24.5 D To + 28.5 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Disposable Sterile Surgical Rubber Gloves Size 8 Inches • Made Of Natural Rubber Latex Powdered,Without Tear,Properly Folded In A Paper • Should Conform To Is 13422 • Isi Marked/Ce Certified/Fda Approved • Colour Code Marking To Designate Size , Disposable Sterile Surgical Rubber Gloves Size 8 Inches • Made Of Natural Rubber Latex Powder Free,Without Tear,Properly Folded In A Paper • Should Conform To Is 13422 • Isi Marked/Ce Certified/Fda Approved • Colour Code Marking To Designate Size , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Extra Small. Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Small Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Medium Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Large Should Conform To Is 15354 , Pressure Monitoring Line / High Pressure Extension Line • Suitable For High Pressure Monitoring And For Connection Between Syringe Infusion Pump And Patient • Male Luer Lock At One End And Female Luer Lock At Other End ; Should Fit All Standard Equipment. Luer Lock Connectors Should Provide Secure Fitting. • Pressure Upto 800 Psi • Length 200 Cm • Sterile , Urine Collecting Bag For New Born /Paediatric Urine Collection Bag, Capacity 100Ml • Should Have Suitability For Both Male And Female Patients • Should Be Provided With Adhesive For Fixation And Good Grip With Minimal Risk Of Allergy And Injury • Capacity 100 Ml • Sterile , Umbilical Catheter (For New Born) All Sizes • Radio Opaque Line • With Female Flexible Mount • Colour Coded Connector • Open Tip Should Be Soft, Rounded, Atraumatic • Length 40 Cm , Umbilical Cord Clamp • Suitable For Clamping Umbilical Cord Of New Born • Security Lock To Prevent Accidental Opening After Clamping • Grooved Clamping Area , Absorbable Oxidized Regenerated Cellulose Net Size 2X 3 With Surgical Sponge Topical Absorbable Haemostatic Bactericidal Property , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And YConnector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter 16 Fg , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And YConnector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter 18 Fg , Bone Cement With Antibiotics,Fast And Slow Setting , Sanitary Napkin, Beltless 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc. 3. Back Strip - A Back Strip For Sticking The Sanitary Napkin Onto The Underwear Should Be There Using Good Quality Adhesive Material. 4. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Total Pad Length 210 +_ 10 230 +_ 10 Width 60 To 75 70 To 85 Thickness 8 +_ 2 5. Weight : Not More Than 10 Gm . . Instruction For Usage Should Be Mentioned On Every Packet , Sanitary Napkin, Belttype 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc 3. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Pad Length 220 +_ 10 Width 70 +_ 5 Thickness 17 +_ 3 4. Weight : 12 +_ 3 Gm 5. Pack - Six Napkins In A Pack. 6. Elastic Belt With Loops Shall Be Provided In Each Pack. 7. Absorbency: The Napkin Should Be Able To Absorb Not Less Than 30 Ml Of Normal Saline Or Coloured Water Or Test Fluid When Poured On To The Centre Of The Napkin At The Rate Of 15 Ml Per Minute. .Instruction For Usage Should Be Mentioned On Every Packet. , Oxygen Mask (Adult) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. , Oxygen Mask (Paediatric) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. • Mask Connector 4M , Sterile Catheter, Single Use, For Urinary Drainage(Foley Baloon Catheter), 2 Way, Size 14 • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For A Traumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30+- 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Ballon Capacity Should Be Mentioned As Per Is 11497 • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 , Nelaton - Catheter Size 14 Fg Distal End Is Close And Proximal End Has Female Colour Code Connector • Soft, Kink Resistant Medical Grade Pvc Tube • Length:40 Cm • Individually Packed In Poly And Sterile , Ecg Electrode •Reliable Trace, •High Conductivity,• Easy To Handle , Surgical Blade Sterile, Size 23 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 50 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Urethral Catheter 90 (Fg-14), Made Up Of Medical Grade Pvc , Urethral Catheter 91 (Fg-10), Made Up Of Medical Grade Pvc , Vaccum Suction Set, 2.5 Meter Length, •Suction Handle With Suction Tube •Sterile,• Pyrogenic Free, •Latex Free,• Single Use , Epidural Minipack 18G, 90 Mm, Metal Stylet For Single Use Only, •Sterile, •Epidural Catheter 20G, L 90 Cm, •6 Lateral Holes Closed End, •Borst Adapter •Epidural Catheter Flat Filter 0.2 Micro Meter •Thread Assist Guide•Lor (Loss Of Resistance) Plastic Syringe 6 Ml , Vascular Catheter 16G/5Fr, Double Lumen Length 40Cm.Usfda/ Four Digit Notified Ce Approved, Should Have Two Guide Wire 45Cm & 80Cm Or More (Logline Iv.) Peel-Away Sheath Glide Thru 5Fr*10 Cm, Guide Wire Nitinol 80 Cm, Guide Wire Nitinol 45 Cm Introducer Needle 21 G *7 Cm, Syringe - 10 Ml Tuer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape, 5 Fr Pressure Injectable Picc Line With Blue Flex Tip 40 Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter With Metal Guide Wire, 4Fr Single Lumen, Distalvalve, Saline Flush Only Size 45Cm Or More Usfda/ Four Digit Notified Ce Approved (Logline Iv.) Internal Stylet, Statlock Stabilization Device (Suture Less), Introducer Needle, Micro Introducer With Vessel Dilator, Guide Wire- 50 Cm Nitinol, Safety Scalpel,Suture Wing, End Cap , Vascular Catheter With Metal Guide Wire 3Fr Single Lumen,Micro Introducer,Contrast Media Compatible, Size 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml,Internal Stylet,Measuring Tape,Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G, Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G, Safety Scalpel, End Cap , Vascular Catheter 7Fr-16 Cm With Chlorhexidine, Silver Sulfadiazine Coated Triple Lumen Usfda/Bis With Testing Standard. Introducer Needle 18 G., Spring Guide Wire 45 Cm J Tip, Dilator 8.5 Fr., Raulerson Spring Introduction Syringe 5 Ml , Vascular Catheter 5Fr/16G, Double Lumen Length 50Cm.Usfda/Four Digit Notified Ce Approved. Should Have Two Guide Wire 45 Cm & 80Cm Or More(Logline Iv.) Peel-Away Sheath Glide Thru 5Fr *10 Cm, Guide Wire Nitinol 80 Cm, Guide Wire Nitinol 45 Cm, Introducer Needle 21 G *7 Cm, Syringe-10 Ml Luer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape,5 Fr Pressure Injectable Picc Line With Blue Flex Tip 50 Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter 5Fr/16G, Double Lumen Length 55Cm.Usfda/ Four Digit Notified Ce Approved, Should Have Two Guide Wire 45Cm & 80Cm Or More (Logline Iv.) Peel-Away Sheath Glide Thru 5Fr *10 Cm,Guide Wire Nitinol 80 Cm,Guide Wire Nitinol 45 Cm,Introducer Needle 21 G*7 Cm, Syringe-10 Ml Luer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape,5 Fr Pressure Injectable Picc Line With Blue Flex Tip 55Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter With Metal Guide Wire 5Fr Double Lumen, Introducer Safety Piv Catheter20g, 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml, Internal Stylet, Measuring Tape, Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G,Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G,Safety Scalpel, End Cap , Vascular Catheter With Metal Guide Wire,5Fr Triple Lumen, Size Range 55Cm Or More (Logline Iv:) Usfda/Four Digit Notified Ce Approved Syringe 12 Ml, Internal Stylet, Measuring Tape, Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G,Micro Introducer With Vessel Dilator, Guide Wire-50 Cm Nitinol, Needle Introducer 21 G, Safety Scalpel,End Cap , 3 Way Stop Cock , Non Pyrogenic & Single Use, Should Be Leak Proof, With Smooth Movements , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 10 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 50 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 100 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 150 Cm (Non Pyrogenic & Single Use) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 16) • Graduated Bag, • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 20) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Nasal Pronge Neonatal (Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube , Elastic Adhesive Bandage Bp 1M X 10Cm Adhesive Material Should Have Good Quality Sticking Property, Non-Allergic , Sterile Disposable (Single Use Teflon/Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 26G · Should Be Packed In Transparent Single Blister Pack · Should Confirm To Is 10555 Standard · (Neonatal Iv Cannula Size 26) , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Large Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Ventilator Without Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Medium Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Ventilator Without Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Large Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Bipap With Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Medium Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Bipap With Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Paediatric · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads In Small Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear · Should Be Single Use With Bronchoscopy And Co2 &O2 Port With Chin Support · Non Allergic, Leak Proof, Contour Should Be Maintained , Nebulization Mask Adult , Nebulization Mask Paediatric , Chemotherapy Port &Non-Coring Needles(Adult) · Valved Catheter Need Only Saline Flush, Catheter With Intermediate Size Port With Small Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio-Opaque Ring. 8Fr With Silicon Material With Peel Apart Percutaneous Introducer System. · Chemo Port Huber Needle 20G And 22G. , Chemotherapy Port &Non-Coring Needles(Pediatric) Valved Catheter Need Only Saline Flush, Catheter With Intermediate Size Power Port With Large Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio-Opaque Ring. 6Fr With Silicon Material With Peel Apart Percutaneous Introducer System Chemo Port Huber Needle 20G And 22G. , Core Biopsy Instrument With Compatible Co-Axial Needle (Automatic Disposable) , Bone Marrow Biospy Needle , Eyelid Occlusion Dressings Use For Eyelid , Eye Pressure Shield , Nonabsorbable Polypropylene Light Weight Macroporous Mesh. Usfda/Ce Certificate With Nnotified Body. , Three Dimensional Monofilament Polyester Composite Mesh With Collagen With Glycerol Anti Adhesive Barrier Visceral Side And Stay Suture In Parietal Side Along With Medial. Circular Usfda/Ce Certificate With Notified Body , Three Dimensional Monofilament Polyester Composite Mesh With Collagen With Glycerol Anti Adhesive Barrier Visceral Side And Stay Suture In Parietal Side Along With Medial. Circular Usfda/Ce Certificate With Notified Body , Absorbable 5 Mm Hernia Mesh Fixation Device 30 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4-5 Mm (Should Not Be More Than 5Mm) Length Along With Flexible Shaft Up To 3 Cm. Circular Usfda/Ce Certificate With Notified Body , Absorbable 5 Mm Hernia Mesh Fixation Device 15 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4-5 Mm (Should Not Be More Than 5Mm) Length Along With Flexible Shaft Up To 3 Cm.Circular Usfda/Ce Certificate With Notified Body , Non Absorbable 5 Mm Hernia Mesh Fixation Device With 30 Helical Shaped Titanium Tacks 3.96 Mm Width And 0.61 Mm Diameter Usfda/Ce Certificate With Notified Body. , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Linear Cutter 55Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Linear Cutter 75Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Universal Linear Cutter Cartridge 75Mm Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 75Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 6 Rows 3-D Staple Technology. , Universal Linear Cutter Cartridge 55-60 Mm For Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 55-60 Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 6 Rows 3- D Staple Technology. , Curved Cutter Stapler 40 Mm Linear Cutter Or Curved Shaped Radial Stapler Cartridge For Simultaneous Cutting And Stapling , Curved Green Cartridge Having Close Staple Height Of 2.0 Mm, Tactile Feedback On Completion Of Firing Sequence, New Anvil, Knife With Every Catridge , Circular Stapler 33Mm With Controlled Tissue Compression With Adjustable Staple Hight (1.5-2.2 Mm) For Controlled Tissue Compression Longer Staple Leg 5.2 Mm To 5.5Mm , & Non Slip Grip Surface , Laparoscopic Cartridge For Stapler 60 Mm Blue, 1.5 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Laparoscopic Cartridge For Stapler 60 Mm Green, 2.0 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Procedure For Prolapse And Hemorrhoids Stapler 33Mm - Hemorrhoidal Stapler Kit Consists Of 33Mm Hemorrhoidal Circular Stapler (With Fixed Anvil, Adjustable Closed Staple Height From 0.75 Mm - 1.5 Mm, Staple Open Leg Length Of 4.0Mm - 5.5 Mm), Suture Threade, Circular Anal Dilator, Purse-String Suture Anoscope, Suture For Purse String. , Optically Guided Bladeless Trocar 12Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Optically Guided Bladeless Trocar 12 Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer Length 100Mm. , Facial Closure Device Contain - Optical Bladeless Trocar With Facial Closure Device Comaptible With Clear Cannula Have Two Side Opening Meant For Uniform Port Closure , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Varied Staple Height Reloads/Cartridges For 80 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 60 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 60 Mm Open Linear Cutter Reloads/Cartridges Purpule And Black , Eea Circular Stapler Purple Colour Medium Thick , Triple Row With Tristaple Technology (Three Row Of Staple Inner To Outer Row 3.0,3.5 And 4.0 Mm With Sloped Cartridges Face In One Stapler) Diameter 31Mm , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 80 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 80 Mm Open Linear Cutter Reloads/Cartridges Purpule And Black , Wound Protector With Double Ring In Medium 5-9 Cm , Endo Catch Specimen Removal Kit:With Continuous Ring ,Polyurethane Pouch With 34.5 Cm Shaft Length , 10Mm With Leakproof And Impervious Material To Cancer Cells Of 0.5 Microns/ Pretied Purse String On Pouch Usfda Approved , Disposable Laparoscopic Clip Applier Preloaded With 15/16 Clips, 5Mm Diameter With Clip Logic Technology/Over Load Mechanism And Digital Display/Clip Indicator Titanium Alloy Clips- U Shaped. , Laparoscopic Liner Cutter Without Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 45Mm Capable Of Loading All Length Cartridges On Same Gun Only , Laparoscopic Liner Cutter With Or Without Integrated/ Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 60Mm, Capable Of Loading All Colour Coding 60Mm Cartridges On Same Gun. , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,9Cm Length,16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Up To And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip- Focus 9 , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,17Cm Length,16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Upto And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip - Focus 17 , Advance Bipolar Hand Activated Probe With 5Mm Shaft Diameter And 35 Cm Shaft Length With 5 Mm Wide Straight Jaw Design With Seal Length Of 20Mm And Cut Length Of 16Mm,Sealing Vessel Upto And Including 7Mm Through Radio Frequency Energy And Having A Temperature Controlled Mechanism Within The Jaw And Having Articulation Of 110 Degree(55 Degrees On Both Sides) And Capable Of 360 Degrees Rotation , Advanced Bipolar Tissue Sealer 37 Cms, With 5Mm Shaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm Jaw Aperture Designed For Use In Laproscopic Surgical Procedures With Curved And Tapered Tip And Uses An Advanced Algorithm For Intelligent And Efficient Energy Delivery. Device To Have Intuitive Design With Separate Seal And Cut Button And 360 Degree Continuous Shaft Rotation , Laparoscopic Shears 5Mm Diameter,36Cm Long, 18Mm Curved Coated Blade And A Clamp Arm With Tissue Pad, Capable Of Cutting,Sealing,Grasping And Coagulating Blood Vessels Up To And Including 7Mm In Diameter, 360 Degrees Rotation, Advance Hemostasis Hand Activation Mode For Sealing Vessels Upto 7Mm In Diameter ,Ergonomic Handle Compatible With Ultrasonic Energy Source, Capable Of Hand And Foot Activation With An Integrated Hand Piece And Transducer. , Connecting Cable For Ultrasonic Harmonic Scalpel For Open Energy Probes Compatible With Focus Plus Shear- Hp Blue , Connecting Cable For Ultrasonic Harmonic Scalpel For Lap Energy Probes Compatible With Ace Plus Shear Hp054 , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (2*2 ) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (1*2) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (1*1 ) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (2 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (1.5 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (2.5 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (3 Mm) Diameter Drill Bit Machine With Insertion Tools , Speech Prosthesis For Laryngectomy 22.5Fr (6 Mm) , Speech Prosthesis For Laryngectomy 22.5Fr (8 Mm) , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 2.0,2.5 And 3.0 Mm Staple Heights Row For Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm Tan Colour Code For Vascular Applications , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 3.0,3.5 And 4.0 Mm Staple Heights Row For Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm Purpule Colour Code For Medium To Thick Tissue , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Black Varied Staple Height Of 4, 4.5 And 5Mm Leg Length , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm Or Size 2-3*5- 6Cm , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 5*10Cm Or Size 5-7*7- 11Cm Or Size 4*8Cm , Disposable 10 Mm Endoscopic Clip Applier With Facility Of Loading Clips Independent Of The Firing Mechanism: Medium/Large Size , Disposable Clip Applier Preloaded With 20 Clips, Superinterlock Security With Clip Design Technology Medium , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Urine Collecting Bag, Disposable 2000 Ml With Uroflow Meter , Central Neck Line - Double Lumen (Antimicrobial Coated/ Chlorhexidine , Silver Sulfadiazine Coated) Central Lumen Catheter, Double Lumen) 7 Fr Usfda/Bis With Testing Standard. , Microcatheter For Aneurysm, Two Tip, Outer Diameter-2.1 To 2.4 & 1.7 Fr. Inner Diameter- 0.017 To 0.015. Nitinol Brading, Straight Tip Compatible With 0.014Microwire. It Should Have Radio Opaque Tip & Hydrophilic Coating. , Straight Tip Microcatheter With Four Transtion Zone Proximal Stainless Steel Triple Braid, Distal Segment Stainless Steel With Soft Distal Segment Of 6 Or 10 Cm, Outer Layer Pebax,Inner Layer Of Stainess Steel Braid Coil, Ptfe & Polyolefin Elastomer With Proximal &Distal For Deploying Intracranial Device: Stent Deployment0.027.Id , Straight Tip Microcatheter With Four Transtion Zone Proximal Stainless Steel Triple Braid, Distal Segment Stainless Steel With Soft Distal Segment Of 6 Or 10 Cm, Outer Layer Pebax,Inner Layer Of Stainess Steel Braid Coil, Ptfe & Polyolefin Elastomer With Proximal &Distal For Deploying Flow Divertor Delivery With Single Tip Markar 0.027 Id , Flow Guided Microcatheter Extruded Construction Proximal Size 2.7 F Middle Size 2.4 F Distal Size 1.2 To 1.8 F Working Length 155 To 180. Catheter Endo Hole Diameter 0.009 To 0.13. Compatible With 0.007 To 0.010, It Should Have Radio Opaque Tip & Hydrophilic Coating Compatible With Dmso. , Stinless Steel Hydrophilic Coated 0.14 Neuro Guide Wire With Twister Technology, Microridge Design, Optimized Core Wire Profile 205Cm In Length & Coil Length 5Cm , Aortic Punch 4 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 4.5 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 3.6 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Laproscopic Port With Trocar 5Mm Optically Guided Bladeless Trocar 5Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. 14G X 11Cm To 20Cm , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode- Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. (Size 18Gx11cm Or Above) , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode- Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. (Size 18Gx15cm Or Above) , • Incise Drape Made Up Of Polyester Film With An Acryllc Adhesive That Contains A Complex Of Lodoform (N- Vinyl 2 Pyrrolldine) With A Lodine Concentration Of 0.092 Mg Lodine/Cm2. • Film Should Be Breathable And Conformable To Skin, Compatible With Povidone And Chg Skin Preps. • Lodine From The Drape Should Be Present In The Deepest Skin Layers (1000 Microns Depth) Where Hair Follces Exist Apart From Killing Microbes On Skin Layer. • Produst Should Be Registered As A Class ‘D Medical Devise With Cdsco India Since ItS A Antimicroblal Product. • It Should Be Gamma Sterile And Us-Fda Approved. Size Should Be 56Cm 45Cm (Adhoslve Area) , Rem (Return Electrode Monitoring) Single Use, Corded Patient Return Electrodes Conductive Adhesive Hydrogel With Usfda , Surgical Gloves 6.5 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7.5 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Ionic Silver Highly Absorbent Multilayer Foam Dressing With Broad Spectrum Antimicrobial , Bactericidal Efficacies And Having A Soft Siliconadhesive Wound Contact Layer , Providing Sustain Release Of Silver Upto 7 Days. Size: 10 Cms X 10 Cms And More , Self-Adherent Moist Wound Foam Dressing Made Up Of Multilayer Matrix With Soft Silicon Adhesive Layer For Pressure Ulcers/Bed Sores At Sacrum 16 Cms X 20 Cms And More , Double/Single Wall Resuscitator With Peep Valve In Adult (Double Wall Resuscitator With Peep Valve In Adult It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable/Eto Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult Bag Volume: Mark Iv (1300 Ml Or More) Weight: Adult (415 G) And More It Should Be Us-Fda, Ce & Iso Certified Adult , Double Wall Resuscitator With Peep Valve In Paediatrics It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult & Peadiatric It Should Have Provision To Attach Manometer For Paediatrics Ambu Bag Bag Volume: Mark Iv Baby (300 Ml) Weight: Baby (190 G) It Should Be Us-Fda, Ce & Iso Certified , Single Patient Use Sebs Resuscitator (With Peep Valve In Neonatal 220-300Ml) • It Should Be Single Use Resuscitator Made To Sebs Material Not Pvc. • It Should Have Unique Single-Shutter Valve System For Reliable Functionality & Swivel Between Valve And Mask Permits 360° Positioning In Relation To The Patient • It Should Have Thin-Walled Compression Bag With Hand Strip. • Resuscitator Volume: Neonate(220-300Ml) • (Including Reservoir And Mask) • It Should Be Ce/Iso/ Us Fda Certified. Or As Per Who Specification. , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector (Iso). • It Should Be Ce/Iso, Us Fda Certified , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector (Iso). • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Offset Connector Cardio Sensor Electrodes • It Should Have High Conductive Wet Gel To Ensure Reliable Traces. • It Should Be Design With Offset Connector To Prevent Artefacts From Disrupting The Readouts • It Should Have High Quality Ag/Agcl Sensor To Ensure Excellent Trace Quality • It Should Have Size Not More Than 72 X 68 Mm • • Sizes -Adult , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Ultrasorbs Ap Disposable Drypads, Dry Pad For Moisture Management, 58.4X90cm, With Breathable Layer, Super Absorbent Core, Aqua Shield Film And Air Permeable Back Sheet, Absorbency Of 1800-2300Gm, Usfda/Ce/Bis Compliant, Iso13485 Compliant , Over-The-Ear Nasal Cannula Over-The-Ear Nasal Cannula With Star Lumen, 50 Tubing, Must Be Flexible Contoured Lip Tab Provides A High Level Of Stability And Patient Comfort. Over-The-Ear Design For A Comfortable And Secure Fit, Crush- And Kink-Resistant Tubing. Usfda/Bis With Testing Standard. , Pediatric Nasal Cannula Pediatric Nasal Cannula Softech With Universal Oxygen Connector, 7 Star-Lumen Tubing Lightweight, Flexible Nasal Cannula With Standard Over-The-Ear Designed That Optimizes Fit And Stability, Soft Nasal Prongs Help Maximize Patient Comfort. Individually Packaged For Convenience And Sterility. Manufacturer Must Be Usfda Registered / Certified With En/Eu Iso 13485 / Applicable 510K & Ce Certification. , Volumetric Incentive Spirometer (Adult) Volumetric Incentive Spirometer (Adult) 4000 Ml And Above With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification , Volumetric Incentive Spirometer (Pediatric) Volumetric Incentive Spirometer (Pediatric) 2500 Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Mask For Tracheostomy Adult Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Pardiatric Mask For Tracheostomy Pediatric Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Elongated Aerosol Mask Adult Elongated Aerosol Mask Adult With Under-The-Chin Design For Excellent Fit On Wide Range Of Face Sizes Must Be Clear, Soft Vinyl For Patient Comfort; Adjustable Nose Clip Assures Comfortable Fit; Specifically Designed For Aerosol Therapy; Must Be With Supplied With 6Ft -7Ft. Corr A Flex Corrugated Tubing, Featuring Cuttable Sections Every 6 In. Usfda/Bis With Testing Standard. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilator Circuit Single Limb Portable Adult Ventilator Circuit With Universal Single Limb. Must Be Complete Kit With Main Circuit Hose, Exhalation Valve Manifold, Aerosol Hose, Patient Elbow Connector, Proximal Airway Pressure Line, Exhalation Valve Line, And Humidifier Limb. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilator Circuit Single Water Trap Adult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 70-72 Inch. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us- Fda/ Eu Ce Four Digit Notify/ Iso , Infant Prong Cpap Cannula Infant Prong Cpap Cannula Nasal Size 0 With Designed To Reduce Trauma Associated With Delivery Of Infant Nasal Cpap. Must Be Soft Siliconised, Anatomically Curved Prongs To Enhance Fit. Luer Fitting On Expiratory Connector To Allow Proximal Airway Pressure Monitoring. Each Set To Include, Soft Siliconised Cannula; Inspiratory & Expiratory Elbow Connector; Knit Cap; Two 6 In. Hook And Loop Fastener Sections; Two 10 To 7.5 Mm Adaptors. Manufacturer Must Be Usfda Registered / Certified With En/Eu Iso 13485 / Applicable 510K & Ce Certification. , Fhme Heat And Moisture Exchangers With Bacteria Viral Filters Bacterial Filtration Efficiency≫ 99.99 % And Viral Filtration Efficiency ≫ 99.9999% . Filter Membrane Should Be Of A Hydrophobic Non-Woven Polypropylene Material. Should Be Tailored To Meet The Specific Needs Of Both Anaesthesia And Intensive Care. , Tracheostomy Hme: 1 Heat And Moisture Exchangers For Spontaneously Breathing Tracheotomy Patients. 2 Should Have In Built Oxygen Port. 3 Should Be Compact & Light Wt. 4 Should Be Suitable For Ambulatory Patients, Sampling And Suctioning Can Be Done Without Removing It. 5 The System Should Have Kink Resisting Oxygen Tubing , Double Lumen Endobronchial Tube Left: Size-37Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Double Lumen Endobronchial Tube Left: Size-39Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Manifold Manifolds In 2, 3, 5 Port With Configuration Of Left-Right Orientation, On-Off Handle, Full-Half Body, 200 Psi-500 Psi Rating And Wide Port Spacing. Should Have Clear Polycarbonate Body To Provide Durability And Visibility, Airless Rotator And Large Bore Inner Lumen Throughout Including Rotator Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard. , High Pressure Tube High Pressure Tubing In 25Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard. , High Pressure Tube High Pressure Tubing In 51Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 76Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 122,Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 183Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , Torque Device Torque Device For .014 To .038 Standard And Hydrophilic Guide Wires With Squeeze-Load- Release Mechanism.Usfda Approved , Radial Band Radial Hemostatis Band In 24 Cm . Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Radial Band Radial Hemostatis Band In 29 Cm. Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Angiography Needle Angiography Needle In 18G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Needle Angiography Needle In 20G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Wire Ptfe Guidewire In .035, .038, In Regular Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coating For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , Angiography Wire Long Length Ptfe Guidewire In .035, .038, With Exchange Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coatting For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , H10ydrophilic Wire Long Length Hrophilic Guidewire Of .018, .025, .035, .038 In 150-180Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved. , Hydrophilic Wire Long Length Hydrophilic Guidewire Of .018, .025, .035, .038 In 220-260Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved. , Hydrophillic Braided Sheath Hydrophilic Braided Sheath Introducer In 4F To 7F, Length: 7Cm, 10-11Cm, 15-16Cm, 23-25Cm Or 7-25 Cm With The Option Of .018, .021, .025 Plastic Jacketed And Spring Coil Guidewire. Should Have Ultra-Thin Wall And Flat Wire Braiding Technology To Provide Support And Low Profile.Usfda Approved , Femoral Sheath With Needle Femoral Sheath In 5F To 8F, Length: 11-25Cm With Puncher Needle Of 18G And Guidewire Of .035, .038. Should Have Rotating Suture Ring, Snap-Fit Dilator To Prevent Slipping During Insertion And Holster Pack. Should Be Available In Polypropylene. Usfda Approved , Angiography Radial Catheters Diagnostic Radial Catheter With Radial Ultimate Curve In 4-6F. Lenght Of 100Cm, 110Cm, 125Cm. Should Have Four Type Of Radial Ultimate Curves. Should Have Flat Wire Braiding, Nylon Material, Thin Wall Design For Higher Flow Rates, Radio-Opaque Tip, Strain Relief And Winged Polycarbonate Hub. Us Fda Approved , One Loop & Triple Loop Snare Snare Kit(2-35Mm Diameter, 90-Degree Nitinol & Gold-Plated Tungsten Loop) And Multiloop Snare Kit(2-45Mm Diameter, Three Interlaced Nitinol Loops) For Foreign Body Retrieval, Should Come With Flexible, Reinforced, Strain Relief Hub To Reduce Buckling And Unique Peel Away Insertion Tool. Usfda Approved , Ptca Kit (1) Three Port Manifold With Knobs To TurnRight When Open (2) One Pressure Line, (3) Fluid Connecting Line, (4) Contrast Connecting Line, (5) One Three Way Stop Cock, (6) One Y-Connector Hemoststic Valve With Spring Type Push And Release Mechanism, (7) One Inflation Device With Manometer Upto 30 Atm (Easy To Operate With Luminescent Dial), (8) One Luer Lock Controlled Syringe Of 10 Ml With Finger Grip, (9) Insertion Needle, (10) Torque Device.Usfda Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material.Sizes Are 5Fr. , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 6Fr , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 7Fr. , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 8Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.S Eparate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes Are 10Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 12Fr. Usfda/ Notified Ce Approved , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3.5Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 5.5Mm , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. T Size 13Fr . , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. Sizes 16Fr. , Catheter Mount Double Swivel Connector, It Should Have Bronchoscopy Port . It Sholud Be Approved By Us Fda , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilized Size - 20Fr Length (0.8 - 5.0) , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilized Size - 24Fr Length (0.8 - 5.0) , Percutaneous Endoscopic Gastrostomy (Peg) 24Fr Percutaneous Endoscopic Gastrostomy (Peg) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus Feeding Port Connectors,Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe And Bumper.Tubing Clamp.Eto Sterilized.Sizes - 24Fr , Anti Microbial Gloves 6 , Anti Microbial Gloves 6.5 , Anti Microbial Gloves 7 , Anti Microbial Gloves 7.5 , Anti Microbial Gloves 8 , Anterior Chamber Iol Pmma Material, Single Piece Kelman Multiflex Design5-6 Mm Optic Size With 12-13 Mm Overall Size Biconvex Power Range +12 To +24Should Be Iso Or Ce Certified. , Capsular Tension Ring Standard Capsular Tension Ringpmma Material With One Eyelet Each At Each End 10 Mm To 12 Mm Overall Diameter Sterile Should Be Iso/Ce Certified Mfg. , Neonatal High Flow Nasal Cannula Having 8 Litre Flow. Should Have Soft Tip . , Pur-Xro Catheter 20 Cm, 28G/1Fr Picc Line With Stylet, Splitting Needle With Securing Wings With 8 Cm Extension Tubing (Flow Rate 0.7Ml/Min) , Pur-Xro Catheter 30 Cm, 24G/2Fr Picc Line With Split Cannula And 10Cm Extension Tubing Over Catheter (Flow Rate 4.5Ml/Min) , Long Introducer Sheath (20-30 Cm Long) (Size 5Fr..) Us Fda + Ce/ Dgci Approved·Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 6Fr.) Us Fda + Ce/ Dgci Approved·· Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 7Fr.) Us Fda + Ce/ Dgci Approved·Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 4F Us Fda + Ce/ Dgci Approved·Sizes 4 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 5F Us Fda + Ce/ Dgci Approved·Sizes 5 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 6F Us Fda + Ce/ Dgci Approved· Sizes 6 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Ptfe Coated Diagnostic Guide Wire - (Exchange Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Should Be Available In , 0.035 Inches Size· Should Be 240-300 Cm Long· Should Be Available As Straight Or J-Shaped Tip· Should Be Available Fixed As Well As Movable Core. , Hydrophilic Diagnostic Guide Wire - Radifocus Tarumo Type (Regular Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved·Should Be Available In 0.032 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Hydrophilic Diagnostic Guide Wire - Radifocus Tarumo Type (Regular Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Should Be Available In 0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Radiofocus Miniplastic Guidewire (, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Sould Be Available In 0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 150-180 Cm Long , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Multipurpose Catheter Us Fda + Ce/ Dgci Approved Multipurpose Catheters In Various Standard Curves And Lengths. , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , Nternal Mammary Catheter 7Fr Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , By-Pass Graft Catheter 5Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths , By-Pass Graft Catheter 6Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths , By-Pass Graft Catheter 7Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths. , Transradial Diagnostic Coronary Catheter Tiger Type Diagnostic Coronary Catheters Of Tig Curves And Lengths Dedicated For Trans Radial Coronary Angiography And Brachial Approach Also Us Fda + Ce/ Dgci Approved · , Introducer Sheaths For Pediatric Use (Size 5 Fr.) With J Tip/Straight Introducer Wire Us Fda + Ce/ Dgci Approved· Between 5.5-7.5 Cm Long· 0.021 Inch Straight Introducer Guide Wire· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· With Integral Side Port With Attached 3- Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant· With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· Should Have Smooth And Resistance Free Insertion , Arterial Pressure Monitor Lines (100 Cm Long) Us Fda + Ce/ Dgci Approved·Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (150 Cm Long) Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (200 Cm Long) Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Angio.Kit/Ptca Kit (3 Port Many Fold With Attached Tubing One Pressure Line + Two Iv Set Connecting Tube And Two Leurlock Syringe ) Us Fda / Ce/ Approved , Venaseal Closure System For Varicose Veins Usa/Fda Approved N Butyl Based Adhesive Formation 50/90/105/120 Cm 145 Cm(3/4/6/8 F ,014/0.35 Compatible , Bone Marrow Biopsy Needle Size 8G 4 & 6 With Diamond Bevel Tip & Tapered Distal Canula. Disposable Bone Marrow Biopsy Needle Should Have Ergonomic T- Handle Design With Seprate Handle Cap. Should Have Trocar/Diamond Tip For Easy Coring Of Bone. Should Have Triple Crown Cannula Tip With 6 Facets.Should Be Available With Narrow Acquition Cardle With Sample Size Verfication Marking Should Be Available In 8,11,13 Gauze Usfda/Four Digit Ce Approved , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter(18Fr, 2-Way) • Made From 100% Medical-Grade Silicone. • Biocompatible And Non-Reactive, Ideal For Long-Term Catheterization. • 2-Way Foley Catheter (Typically Available); • Smooth, Non-Stick Surface For Easy Insertion And Removal. • Integrated Silicone Balloon For Retention In The Bladder. • Radiopaque Stripe Throughout The Catheter Length For X-Ray Visibility. • Standard (Rounded) Tip. • Available In Sizes Ranging From: 18 Fr). • Follows International Color-Coded System To Identify French Sizes. • Large Symmetrical Drainage Eyes For Effective Urine Flow. • Latex-Free - Suitable For Patients With Latex Allergies. • Universal Funnel-Shaped Connector For Drainage Bag Attachment. , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Having Maryland Jaw Sealer And Divider With Wide Jaw Aperture 13Mm And Cut Length 18.5Mm With Shaft Rotation Of 350 Degrees And With One Step Sealing Mechanism. Should Have The Manual Cutting Mechanism. And It Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting & Coagulations Device With Tissue Fusion Ligature Technology Have Small Jaw Tissue Sealing System For Open Procedures Vessel Sealing Instrument With Cut Length Of 14.7 Mm, Seal Length Of 16.5Mm, Jaw Angle 28 Degrees. Should Have The Manual Cutting Mechanism.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligature Technology Laparoscopic Blunt Tipped Vessel Sealer And Divider 37 Cm Long 5Mm Instrument. Wide Jaw Aperture 14.5 Mm With Shaft Rotation Of 180 Degrees ; Multifunctional Laparoscopic Device For Tissue Fusion.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting & Coagulations Device With Tissue Fusion Vessel Sealing Technology Instrument For Open Surgeries With Instrument Length Between 21-23Cm And Electrode Length Between 17-21Cm Having 22 Degree Curved Jaw With Contoured Tip Activation Both Through Hand Activation And Foot Activation With A Manually Controlled Cutting Mechanism. , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Have 36Mm Jaw Length, 180 Degree Rotatable Instrument With Curved Blade For Large Volume Tissue. Should Have The Manual Cutting Mechanism. , Cutting & Coagulations Device With Tissue Fusion Vessel Sealing Technology Have Vessel Sealing Instrument For Open Surgeries With Reusable Clamp Length Between 16-23Cm, With 12-40 Degree With Straight / Curved Jaw And Its Should Have Including 7Mm Cutting And Coag With Usfda. , Double Lumen Catheter Size- 12 Frx16 Cm Double Lumen Catheter Size- 12 Frx16 Cm (Double Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot)Size- 12 Frx16 Cm With Us Fda / Iso Ce Certified , Double Lumen Catheter Size- 12 Frx13 Cmdouble Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot Size- 12 Frx13 Cm Usfda Along With Iso Ce Certified , Long Term Double Lumen Dialysis Catheter Size- 15 Fr X 27 Cm Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided Catheter, Pull Apart Sheath, Dialator, Tunnelling Stylet, Guide Wire J/S, With Disppenser And Injection Caps, Symmetrical Tip Retrograde And Antigrade Size- 15 Fr X 27 Cm Usfda Certification Along With Iso, Ce. , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Transperant Surgical Wound Dressing Size- 5X 5.72 Cm Tranparent Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidal Protection And Anti Microbial Property. Provide A Waterproof Sterile Barrier To External Contaminating Including Liquids, Bacteria Anf Viruses , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Proteciton And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Multi-Vent Mask Pediatric, Multi-Vent Mask Pediatric, Air Entrainment Masks, Must Be Safe, Simple Delivery Of Variable Oxygen Concentrations. Each Mask To Includes Color-Coded Diluters: Green For Low Concentration, White For Medium Concentration. Locking Ring To Secure Flow Setting. Must Include Adaptor For High Humidity Entrainment. Complete Kit With 7-Ft Oxygen Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Closed Suction Catheter Mdi Port Has Isolated Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane Material, Catheter Has Zigzag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Size 12-Fr Product Should Be Usfda Approved , Closed Suction Catheter Mdi Port Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port.Catheter Is Made Up Of Medical Grade Silicon Material,Catheter Has Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. , Closed Suction Catheter Has Isolated Cleaning Chamber 12 Fr. Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material,Catheter Has Zig-Zag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. Size 12 Fr. , Closed Suction Catheter Mdi Port Has Isolated Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane Material, Catheter Has Zigzag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Size 14-Fr Product Should Be Usfda Approved. , Multifocal Iol Multifocal Iol (Multifocal Iol Biconvex, Single Piece Optic Size 6 Mm, Overall 12-13 Mm Haptics Hydrophobic Single Loop Or Hydrophilic Double Loop Uv Blocking 360 Degrees Square Edge, Sterile Packing Disposable Sterile Injector For Sub 2.8 Mm Incision Power +16 To + 25 D Diffractive Multifocal Design With Near Add +3 To +4 D Iso Or Ce Approved Samples Required For Approval , Glaucoma Drainage Implant (Valved) With Silicon Tube Adult , Glaucoma Drainage Implant (Valved) With Silicon Tube Paediatric , Scleral Fixiated Intraoccular Lense Single Piece Pmma: Optic6-6.5Mm, Overall13.5Mm Haptic With Hole For Suture Fixation , Central Line With Triple Lumen With Y Needle With Syringe And Guide Wire 7Fr To 8.5Fr With 15 Cm To 20 Cm Catheter With Tecoflex/ Polyurathane Material With Usfda Approved. , Post Operative Surgical Cover Dressings Hydrofiber/Foam Dressings With 1.2% W/W Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings With Broad Spectrum Bactricidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , Post Operative Surgical Cover Dressings Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver & Triple Hydrocolloid Matrix Dressings With Broad Spectrum Bactericidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , 2 Pcs Flat Base Ostomy Body Fit 60 Mm Kit 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm, Elastic Tape In Semi-Circular Shape With Hydrocolloid Adhesive For Extra Security Of Base Plate. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm), Neutral Grey Colour Standerd Size Belt Compatible For Bags Having 4 Ear Hooks , 2 Pcs Convex Base Ostomy Body Fit 60 Mm Kit Two- Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm)Neutral Grey Colour Standerd Size Belt Compatible For Bags Having 4 Ear Hooks , 1 Pcs Trasnparent Colostomy Body Fit 60Mm Kit One- Piece Colostomy Bag- Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.34 N/Mm), Bag Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. One Side Transparent For Inspection 60Mm. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm) , 2 Pcs Flat Base Ostomy Body Fit Bag 60 Mm 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. Window On Bag For Inspection 60Mm . With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic. , 2 Pcs Flat Base Ostomy Body Fit Bag 70 Mm 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. One Side Transparent For Inspection. 70Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , 2 Pcs Convex Base Ostomy Body Fit Bag 60 Mm Two-Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material. Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. . Window On Bag For Inspection 60Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , Antimicrobial Transperant Provides Immediate And Continuous Antimicrobial Protection With Integrated Chlorhexidine Gluconate (Chg) Gel Pad, Proven To Reduce Crbsi And Vascular Catheter Colonization, Size 11.5Cm To 8.5Cm, Breathable Film Coating Provides A Barrier To Microbes* And External Contaminants Size 11.5Cm To 8.5Cm, , Sterile Self Adherent With Lipido Colloid Technology / Safetac Layer Sterile Self -Adherent Patented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. Size 13X13 Cm And More , Sterile Self Adherent With Lipido Colloid Technology / Safetac Layer Sterile Self -Adherent Patented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. Size 10X25 Cm , Polysiloxane Or Silicone Gel Sheet For Scar Management. Size 10 * 10 Cm Or 10X18cm , Polysiloxane And Silicone Gel Sheet For Scar Management Size 5 X5 Cm , Triple Layer Antimicrobal Form Dressing For Burn Wound With Silver Sulphate, Silver Content 1.2 Mg/Cm 2 With Active Release Of Silver Upto 7 Days With Soft Silicon Atraumatic Wound Contact Layer For Painless Dressing Change. Product Should Be Ce/Usfda Certified Size 20X20 Cm (45Mm) + 15% Deviation Insize Will Be Acceptable. , Triple Hydrocolloid Skin Barrier Where No Cutting Is Required Comprised Of Pectin, Gelatin And Sodium Carboxy Methyl Cellulose,Elastomeric Polymers Extending Turtlenecking Effect And Rebounding Memory Technology With Audible Click And Flexible Tape Collar. , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour Code, Usfda Approved , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour Code, Usfda Approved 10Mm , Nasal Haemostatic Sponge Pack With Out Airway 8Cm , Nasal Haemostatic Sponge Pack With Out Airway 10Cm , Nasal Haemostatic Sponge Pack (With Airway) 8Cm , Flexomatlic Tube 3-8.5 With Stylet Reinforce Et Tube With Wiring From Tip To End. It Should Be Usfda/Ce/Bis/Is. , Disposable Transducers For Invasive Pressure Monitoring Compatible With Available System In Cath Lab In Smsh Us Fda + Ce/ Dgci Approved· Disposable Transducers For Invasive Pressure Monitoring· Should Be Compatible With Available System In Cath Lab (Iabp - Data Scope & Cath Lab Transducer) And Iccu At Smsh· Should Meet Highest Medical Industrial Standards· Quality Certification Should Be Provided Form Authorized Agencies , Dialyzer Size 1.3 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.4 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.6 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.8 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Padiatric Dialyzer Size 0 .6 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , Padiatric Dialyzer Size 0.8 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (3/8 Cir Rb Needle 40Mm Length 76 Cm)Size 1/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 20Mm Length 76 Cm) Size 3/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 30Mm Length 76 Cm) Size 2/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 30Mm Length 76 Cm) Size 1/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 40Mm Length 76 Cm)Size 1/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (3/8 Rb Needle 30Mm Length 76 Cm) Size 2/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (1/2 Cir Rb Needle 45 Mm Length 100 Cm) Size 1 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 26Mm, Length 76 Cm) Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) ½ Cir Rb Needle 20Mm Length 70 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Rb Needle 30Mm Length 90 Cm Size 2/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Rb Needle 30Mm Length75- 90 Cm Size 1/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Tapercut Needle (Heavy) 35- 40Mm Length 75-90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) ½ Cir Rb Needle40mm Length 90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Conventional 25Mm Length 90 Cm)Undyed Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Rb Needle 20Mm Length 70 Cm) Size 4/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide ) (1/2 Cir Rb Needle 40Mm Length 90 Cm Size 2/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Rb Needle 40Mm Length 90 Cm) Size 1/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 3/8 Circle Cutting Needle 22Mm Length 45 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 3/8 Circle Cutting 16Mm Needle, Suture Length 70Cm Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (1/2 Cir Rb Needle 20Mm, Length 76 Cm) Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (3/8Cir Reverse Cutting Needle 26Mm, Length 76 Cm) Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (3/8Cir Reverse Cutting Needle 45Mm, Length 76 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suturepolyamide Monofilament Black (Nylon) (3/8 Cir Micropoint Round Body ,6Mm Length 38 Cm) Size 8/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Conventional Cutting Needle 16 Mm Length 70 Cm)Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Conventional Cutting Needle 19Mm Length 60 Cm.)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir Slim Blade Cutting Needle 15Mm Length 70 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir R Cutting Needle 40-45Mm Length 60-70 Cm.)Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir R Cutting Needle 45Mm Length 70 Cm.)Size 1/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb 13 Mm Needle,Length 75Cm) Double Armsize 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb 16Mm Needle,Length 90 Cm) Size 6/0 , Non Absorbable Surgical Suture,Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb Double 8Mm Needle, Length 60 Cm)Size 7/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb 16 Mm Needle, Length 70 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 30Mm Length 90 Cm) Size 1/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Heavy Needle 40- 45Mm Length 75-100 Cm) Size 1 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Double Needle Cutting Size 16-17Mm Length 70-90 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Double Needle 17Mm Length 70-90 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 25Mm, Length 90 Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 30Mm, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Needle 17Mm Length 75 Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Needle,25 Mm Length 90 Cm) Double Armsize 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue Usp(3/8 Cir Conventional Cutting Pc-3Needle 15Mm Length 60Cm)Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Rb 13Mm Needle, Length 90 Cm Double Armsize Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 16 Mm Length 70 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Cutting Needle 25Mm Length 45 Cm)Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Heavy 40Mm, Length 90 Cm) Size 1 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (L/2 Cir Reverse Cutting, 45 Mm Needle Length 100 Cm) Size 1 , Non Absorbable Surgical Suture, ,Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Rb , 8Mm Double Needle, Suture Length Of 70Cm) Size 8/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle Tapercut 13Mm Double Needle 70Cm)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle cement concrete 13Mm Needle, Suture Length Of 70Cm) Double Arm Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle Tapercut Needle 17Mm Suture Length Of 90Cm) Double Armsize 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 25Mm, Suture Length Of 75Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided Green/ Blue (1/2 Cir Tapercut ,17 Mm Double Needle, Length 75 Cm)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided White (1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided Green / Blue (1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture Sterilized Surgical Needled Suture Polybutylate / Silicon Coated With Polyster Braided (Green / Blue) 1/2 Circle Taper Cut , 17Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X L.5Mm Size 2/0 , Non Absorbable Surgical Suture Sterilized Surgical Needled Suture Polybutylate / Silicon Coated With Polyster Braided (Green / Blue) *With 1/2 Circle Taper Cut , 25Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X L.5Mm Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Coated Polyster Braided (Green / Blue) With 1/2 Circle Tapercut Double Needle 25Mm, Suture Length 90 Cm Size 3/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglecaprone, Monofilament Sutures (1/2 Circle Oval Rb Needle 26Mm Needle, Suture Length Of 70Cm)Size 2/0 , Absorbable Surgical Sutures Polyglecaprone, Monofilament Sutures (L/2 Circle Oval Rb Contrast Needle 26Mm, Suture Length 70Cm) Size 3/0 , Absorbable Surgical Sutures Monofilament Sutures Polyglecaprone /Polyglyconate (L/2 Circle Cutting 16Mm Needle,Suture Length 70Cm)Size 4/0 , Absorbable Surgical Sutures Polyglecaprone / Polyglyconate, Monofilament Sutures (3/8 Circle Cutting24- 26Mm Needle, Suture Length Of 70-90Cm)Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Reverse Cutting 40- 50 Mm Length 70- 90Cm) Size 1 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Rb 31Mm Needle, Length 70Cm) Size 2/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Rb 30Mm Needle, Length 70Cm) Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet) 1/2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm/ Size 1 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)1/2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)1/2 Circle Round Bodied 30Mm, Suture Length 90 Cm/ Size 2/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)1/2 Circle Reverse Cutting,Os 40Mm, Suture Length 90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)1/2 Circle Reverse Cutting 36Mm, Os Needle, Suture Length 90 Cm/ Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet) 1/2 Circle Round Bodied 20Mm, Suture Length 70 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)3/8 Circle R Cutting, Ps-1,24Mm, Suture Length 70 Cmsize 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cutting Spatulated Edge Needle, Double Arm Needle 6 Mm, Suture Length 30-42 Cm Size 10/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 16Mm, Length 76 Cm) Size 5/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Cutting Needle 8Mm, Length 35 Cm) Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk With Needle Silk (3/8 Cir Rb Needle 20Mm, Length 76 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk With Needle Silk (3/8 Cir Rb Needle 16Mm, Size 5/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 16-19Mm Length 76 Cm) Size 4/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglyconate, Monofilament Sutures (1/2 Circle Oval Rb Needle 26-30Mm Needle, Suture Length Of 70Cm) Size 2/0 , Absorbable Surgical Suture Polyglyconate, Monofilament Sutures (L/2 Circle Oval Rb Contrast Needle 20-26M M, Suture Length 70Cm) Size 3/0 , Braided E Caprolactone Coated Lactomer 1, 90Cm Gs-25,37-40Mm1/2 Circle Taper Point , Braided E Caprolactone Coated Lactomer 2-0 90Cm Gs-25,3Omm1/2 Circle Taper Point , Braided E Caprolactone Coated Lactomer 1 90Cm Gs-25,37-40Mm1/2 Circle Reverse Cutting , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Taper Point, 90 Cm , Braided E-Caprolactone Coated Lactomer 3-0 75Cm C-14 , Undyed 24Mm 3/8 Circle Reverse Cutting , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,30Mm Needle, Size 2-0, 1/2 Circle Taper Point, 90 Cm , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Reverse Cutting Os Needle, 90Cm , Braided E-Caprolactone Coated Lactomer 0 90Cm Gs-24 , Violet 40Mm 1/2 Circle Taper Point , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,20Mm Needle, Size 3-0, 1/2 Circle Taper Point, 70 Cm , Braided E-Caprolactone Coated Lactomer 1-0 90Cm Gs-25 , Dyed/Undyed 37- 40Mm 1/2 Circle Reverse Cutting , Polyglactin 910 Violet Braided, 1, 35 Cm 1/2 Circle Reverse Cutting (Heavy) 23 Mm -25 Mm Needle , Polyglactin 5-0 Rb Oval ½ Circle 16 Mm 45 Cm , Polyglactin 5-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure Mp, Purest Form Of Triclosan, 26Mm Needle, Size 2-0, 3/8 Circle Cutting, 90 Cm , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point, 17-20Mm Needle, Length 70Cm Size 3-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point Rb-1, 17 Mm Needle, Length 70Cm Size 4-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 1/2 Circle Taper Point Rb-2, Double Needle, 13 Mm Needle, Length 70Cm Size 5-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 3/8 Circle Taper Point, Bb Single Armed Needle 17 Mm Needle, Length 70Cm Size 5-0 , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 17 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Single Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 17 Mm Needle Length 90 Cm , Monofilament Polyglyconate 1 150Cm Gs-25 Loop, Green 48Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 2-0, 75Cm Green 26-30Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 3-0, 75Cm Green 20-26Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 4-0, 75Cm Green 17-20Mm 1/2 Circle Taper Point , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 3-0,70 Cm,1/2 Circle Rb,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 4-0,70 Cm,1/2 Circle Rb,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 5-0,70 Cm,1/2Circle R.B.,13 Mm , Monofilament Glycomer 1 90Cm Gs-21 , Violet 37Mm 1/2 Circle Taper Pont , Monofilament Glycomer 2-0 90Cm Gs-21 , Violet 37Mm 1/2 Circle Taper Pont , Non Absorbable Surgical Suture, Sterilized Surgical Needled Black Braided Silk With Needle 1/2 Circle Round Body 30 Mm Needle , Length 70 Cm Size 2-0 , Braided Coated Non Absorbable Suture Usp 1-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 2-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 3-0 75 Cm X 2 , Silk Reel 4-0 , Braided Polyester Caoted With Silicon 2, 26Mm 1/2 Circle Rc 75Cm , Braided Polyester Caoted With Silicon 5, 55Mm 1/2 Circle Rc 75Cm , Polypropylene Blue Monofilament, 2-0, 90 Cm 1/2 Circle Round Body Double Needle26 Mm , Polypropylene Blue Monofilament Usp 3/0,2,90 Cm,1/2 Circle Taper Point (Double Armed),26 Mm , Polypropylene Blue Monofilament, 4-0, 75 Cm 1/2 Circle Round Body Double Needle 17 Mm , Polypropylene Blue Monofilament Usp 5/0,1,90 Cm,1/2 Circle Taper Point (Double Armed),18 Mm , Polypropylene Blue Monofilament, 6-0, 75 Cm 3/8 Circle Round Body (380 Microns) Double Needle (Cutting) 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0,3/8 Circle C1 Taper Point Cv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,8 Mm,60 Cm , Monofilament Polybuetester Coated With Polytribiolate 6-0 75Cm 2Xcv-1X36 , Blue 9Mm 3/8 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 4-0 90Cm 2Xcv-23X36 , Blue 17Mm 1/2 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 7-0 60Cm 2Xmv-175-8 , Blue 8Mm 3/8 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 2-0 90Cm 2Xv-20X 36 , Blue 26Mm 1/2 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 3-0 90Cm 2Xv-20X36 , Blue 26Mm 1/2 Circle Taper Point , Non-Absorbable Synthetic Unidrectional Dual Cut Angle Barb With Welded Loop Or Tab End Made Up With Polybeutester Size 1, 37Mm, 30Cm, 1/2 Circle, Taper Point , Synthetic Nonabsorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polybeutester Blue Size 2-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Absorbable Synthetic Unidirectional Dual Cut Angle Barbed With Welded Loop Or Tab End Made Up With Polyglyconate 2-0 26-30 Mm 30 Cm 1/2 Circle Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 1-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 2-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 3-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop On End Madeup With Glycomer Blue Size 2-0, 1/2 Circle, 24Mm, 30-45Cm Rc , Polyester Ethylene Terephthalate Nonabsorbable Surgical Braided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate.) Long-Chain, Linear Polyesters 1 /2 Circle Tapercut 2 X V-5 Double Needle 26 Mm 90 Cm Green Color Size 2-0 , Laproscopic Knotless Pga -Pcl Bidirectional Taper Point Surgical Suture Self Fixation Device With Autolock Mechanism Made Up Of Pga -Pcl Bidirectional Taper Point 17 Mm & 32Cm , Absorbable Antibacterial Polydiaxonone Monofilament Taper Point Surgical Suture Absorbable Antibacterial Suture Made Up Of Polydiaxonone Coated With Triclosan Violet Monofilament 1/2 Circle Taper Point Ct-1 40 Mm Needle 90 Cm Suture Size 1 , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 1-0,90 Cm,1/2 Circle R.B.,30 Mm , Non-Absorbable Surgical Suture Black Braided Silk 1-0 Rc 3/8 Circle 45 Mm 76 Cm , Non-Absorbable Surgical Suture Black Braided Silk 5-0 Rc 3/8 Circle 12 Mm 76 Cm , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 5-0,76 Cm,3/8 Circle R.B,12 Mm , Non-Absorbable Surgical Suture Black Braided Silk 6-0 Rc Mp 3/8 Circle 8 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 2-0, 1/2 Circle Taperpoint, 36 Mm,100 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 6-0 Rb Micro Point ¼ Circle 8 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 4-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 3-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 5-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 5-0 Rb Oval 1/2 Circle 16 Mm 45 Cm , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 26Mm Length 70Cm3-0 , Non Absorbable Surgical Suture Sterilized Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm4-0 , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm 5-0 , Non Absorbable Polypropylene Surgical Sutures Size:6-0,3/8 Circle 175-6 Taper Point /Rc Bv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0, Compound Curve ( 1/2 & 3/8 Circle) Circle 175-6 Taper Point Blackmatte Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm , Monofilament Synthetic Absorbable Suture Poliglecaprone 25 - Undyed Ep 3-0,70 Cm,1/2 Circle Oval R.B. J.B. Needle,26 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 3-0, 3/8 Circle Reverse Cutting,Ps Prime 24 Mm,75 Cm , Gauze Than 120Cm X 9 Mtr (Jk47) , Absorbent Cotton Wool Ip 500 Gm , Cotton 200 Gm (Jk153) , Cotton Bandage 4Inch (4.0419) (10Cm X 9 Mtr ) , Cotton Bandage 6Inch (4.042) (15Cm X 9 Mtr ) , Baby Diaper Small (Pba001) , Disposable Appron / Plastic Appron , Shoe Cover (Jk201) , Disposable Needle 22No , Disposable Needle 23No , Disposable Needle 24 No , Disposable Needle 26 No , Infant Feeding Tube 6G (4.0747) , Spinal Needle With Pencil Point Tip Having Tranparent Grooved Hub And Introducer Needle Size 27G X 3.5Inch (4.1315) , Opthalmic Micro Surgical Crecent Blade , Opthalmic Micro Surgical Knife(Keratom) , Ear Buds , Medical Body Protector Premium , Pure Type 1, Triple Helical, Porous Collagen In Particle Form (Fish Origin) With Mupirocin Usp 2% W/W And Metronidazole Ip 1% W/W, Size- 10Ml , Super Oxidized Solution With Neutral Ph Containing Hypochlorous Acid (0.003%) And Sodium Hypochlorite (0.004%) For Wound Treatment In Spray Bottle Of 500Ml , Advanced Fluid Administration System With Air Stop & Prime Stop With Integrated Back Check Valve Bacterial Retention Air Vent, Transparent Spike Designed In Accordance With Iso 8536-4, Transparent Drip Chamber (Double), 15Micron Fuild Filter In The Chamber Medical Grade , Porus Resorbable Collagen (Pure Type-1) Sheet In Nylon Mesh-Dry Form (Fish Origin)-Size- 10X10cm , Non-Occulusive Wound Contact Layer Consists Of Silver Healing Matrix Made Ofp Polyester Mesh Impregnated With Hydrocolloid Particles( Cmc), Petroleum Jelly, Polymers And Silver Salts With Demonstrated In Vitro Antibacterial Activity Upto 7 Days, Using Lipido- Colloid Technology (Tlc) , Size-10X12cm , Pure Poly Siloxane Based Silicone Scar Management Product In Sheet Form(100% Poly Siloxane And Nylon Polyamide Mesh) -Size- 10X10cm, , G Dress 10.5*25Cm , G Dress 8.5*6.5Cm , Amorphous Hydrogel In Applipak Composing Of 2.3% Carboxymethylcellulose,20.0% Propylene Glycol & Purified Water, Promotes Rapid But Gentle Debridement Of Necrotic Tissue. Size 25Gm , Triple Chambered Nutrition(3 In One) For Periperal Iv Emlusions 1800Ml-2100Ml With 80% Olive /20% Soya Lipid,Amino Acids,Glucose & Electrolytes. Tpn 1Ltr Triple Chamber Bag Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L , Non-Leadradiationprotectiongloves - Bis Certified , Latex Free Disposable Pencil Point Spinal Needle 27G , 127.5 Mm With Grooved Transparent Hub With Centering Protective Plastic Sleeve, Touhy Needle With Black Eye - 18 G (1.3 X 88 Mm). Protrusion Of Spinal Needle Through The Back Eye Of The Epidural Needle. With Epidural Catheter, Filter, Loss Of Resistance Syringe And Separate Locking Device - Docking System. , Electrolysed Non-Toxic, Non-Irritant And Non-Corrosive, Ready To Use Disinfectant Solution With Neutral Ph Containing Sodium Chloride (Na Cl)- )0.023%, Sodium Hypochlorite (Naocl)- 0.005%, Hypo Chlorous Acid (Hocl)- 0.004%, Electrolysed Water- 99.97% In Jerricane Of 5 Litre
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
2.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
3.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
4.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
5.
Petroleum and Natural Gas #11279164 AOC
Bids Are invited for Custom Bid For Services - Hiring Of One Time Services For Maintenance Of Field Instruments And Control Valve For Uran Plant Instrumentation Section - Removal From Line, Dismantling, Cleaning Of Valve & Actuator Parts, Inspection, Reassembly & Pressure Testing (For Leakage) & Actuator (For Pneumatic Supply Leakage). Supply & Replacement Of Gland Packing, Etc. To Arrest Leakage & Followed By Servicing Of I/P & Valve Positioner, Air Filter Regulator, Etc. & Its Calibration. Bonnet Gasket To Be Replaced With New (Unit Rate To Be Quoted Per Inch Of Valve Size) , Welding & Machining Of Valve (Inch Of Valve Size) , Lapping Of Control Valves: Lapping & Testing With Water / Air & Arresting Of Seat Leakage Within The Permissible Limit As Per Valve Data Sheet Or As Per Requirement (Unit Rate To Be Quoted Per Inch Of Valve Size) , Cage Grinding & Polishing (Unit Rate To Be Quoted Per Inch Of Valve Size) , Removal From Line And Installation Of The Valve Into The Pipe Line For Globe Valves, Butterfly Valves ,Shutoff Valves/On-Off Valves/Shutdown Valves& Ball Valves (Unit Rate To Be Quoted Per Inch Of Valve Size). , Stelliting At Seat Contact Of Valve Plug And Seat (Rate To Be Quoted As Per Inch Of Valves Size) , Online Servicing Of Control Valve Which Includes Servicing & Calibration Of Valve Positioner / Smart Positioner (Parts Replacement Not Covered) & I/P Converter, Stem Greasing, Servicing Of Filter Regulator, Relays And Stroke Checking - For All Type Valves & Actuator. , Disassembly Of Actuators (Including Piston Cylinder Actuators), Cleaning Of Parts, Greesing, Reassembly, Testing Of Joints, Testing And Calibration Of Actuators, Servicing, Cleaning And Calibration Of Positioners / Smart Positioners (Parts Replacement Not Covered), I/P & Air Filter Regulator (For Globe / Butterfly Valves) (Unit Rate To Be Quoted Per Inch Of Valve Size) , For 8 To 10 , For 4 To 6 , For 2 To 3 , Removal Of Level Gauges (Reflex / Magnetic) From The Flanges / Union Of The Vessels . Cleaning Of The Gauges And The Refitting The Same. If Any Leakage Found After Taking In Line, The Same Should Be Rectified By The Contractor.( Unit Rate To Be Quoted Per Gauge Glass). , Same As Item 120 But For Pvc Flanges/Valves,Cocks (Unit Rate To Be Quoted Per Guage Glass) , Level Switches & Transmitters : Dropping The Level Switches & Transmitters From The Vessel / Standpipe, Removal Of Floats, Cleaning Of Transmitters / Switches Cage Inside & Outside, Hydro Testing. After Hydro Testing, Refitting Of Floats & Flanges & Calibration Thereafter. (Unit Rate To Be Quoted Per No.) , Size : Up To 3 , Size : 4 To 6 , Size : 8 To 12 , Size : 14 And Above , Assembling & Dismantling Of Scaffolding As Per Requirement (Rate Per Cubic Meter) (Scaffolding Material Shall Be Provided By Ongc) , Valve Transportation Charges To And Fro (Unit Rate To Be Quoted Per Consignment) : , 2 1/2 , 3 , 4 , 6 , 8 To 12 , 14 To 20 , 22And Above
Contract Date: Ref. Documents Contract Value : 9.65 Lakh
Boards / Undertakings / PSU No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
7.
Water Resources and Irrigation #11223260 Price Bid
Tender for Repair Of Control Panel And Providing/Fitting Of Foot Valve Of Priming Pump Along With Allied Works At Lis Khawas Khan. , Repair And Reconditioning Of Existing 125 annual periodical maintenance Lt Control Panel Of 415 Volts, Ac 3 Phase, 50 Hz At Lift Irrigation Station Khawas Khan Serving 2 Nos. Motors Of 20 Hp Each By Way Of Replacement Of Faulty/Non-Functional Multispan Mpd 192 (Or Equivalent Isi Standard Make) Motor Protection Device/Fault Analyzer After Extracting The Old Damaged One By Way Of Disconnecting All The Existing Wiring Connections At Its Terminals And Removing It From The Panel Enclosure. providing and Fixing Of New Multispan Mpd 192 Or Equivalent Protection Relay In Its Place And Reconnecting All The Control Wiring As Per The Original Wiring Scheme. Setting/Configuration Of The New Protection Device For 20 Hp Motor Parameters Including Overload Threshold, Underload/Dry Run Detection Level, Over/Under Voltage Limits, Phase Unbalance And Earth Leakage Settings As Per Motor Nameplate Data. Replacement Of 3 Nos. Existing L&T Mnx 25 (25 Amp) Air Break Contactors Of The Star Delta Starter Of Motor No. 1 Which Are Undersized For 20 Hp Motor Rating With 3 Nos. New L&T Mnx 40 (40 Amp) Or Equivalent Isi Standard Make Air Break Contactors Comprising Of 2 Nos. 40 annual periodical maintenance Contactors For Main And Delta Duty And 01 No. 40 Contactor For Star Duty After Extracting The Old Undersized Contactors By Way Of Disconnecting The Power Cables And Control Wiring And Removing The Old Contactors From Their Mounting Arrangement. Reconnecting All Power Cables Of Adequate Current Carrying Capacity And Control Wiring To Appropriate Terminals Of The New Contactors As Per The Star Delta Circuit Including Interlocking Connections Between Star And Delta Contactors To Complete The Star Delta Starting Circuit Of Motor No. 01. Replacement Of Any Faulty Led Indicator With A New Led Indicator Of Equivalent Rating, Colour Coding And Size After Extracting The Old One By Way Of Disconnecting The Existing Wiring Connections And Making Proper Connections To The New Indicator. providing and Fixing Of 1 No. New Reset/Selector Switch In Place Of The Existing Faulty Small Black Reset Switch After Extracting The Old Damaged Switch By Way Of Disconnecting The Existing Wiring Connections, Removing The Old Switch Fitting The New Switch Of Equivalent Type Its Place. Reconnecting The Control Wiring To The New Switch To Restore The Manual Reset Function Of The Motor Protection Relay After A Protection Trip Event. Complete Inspection Of All Internal Control Wiring Of The Panel By Way Of Checking The Insulation Condition Of Flexible Copper Cables, Tightness Of All Crimp/Ferrule Terminations At Terminal Blocks, Contactor Coil Terminals, Push Button Terminals, Indicator Lamp Terminals And Protection Relay Terminals. Replacement Of Any Damaged Or Deteriorated Wiring As Per Actual Site Requirement. Verification Of Correct Phase Sequence Of Incoming Supply Using Phase Sequence Meter Before Energization Of The Panel. Testing And Commissioning Of The Repaired/Upgraded Panel On Full Load By Way Of Energizing The Panel After Completion Of All Repair Works, Verifying Healthiness Of All Three Phase Indicator Lamps At Incoming Section, Checking Voltmeter And Ammeter Readings On All Phases Using Selector Switches, Testing Start/Stop Operation Of Both Motors, Verifying Correct Star To Delta Changeover Of Motor No. 1 Starter, Verifying Display And Protection Functions Of The Motor Protection Devices On All Phases And Recording The Full Load Running Current Of Both Motors. Underground Laying Of Aluminum Cable From From Pump Room To The 100 Kva Distribution Transformer Approximately 20 Feet Apart, By Way Of Excavation Of A Trench Of 9 To 12 Inches Depth And 20 Feet In Length Using Manual Labour With Tools And Tackles. Inspection Of Cable And Insulation Of All Joints And Any Other Locations Found Requiring Insulation During Inspection By Way Of Proper Wrapping With Good Quality Pvc Insulation Tape In Multiple Overlapping Layers So As To Ensure A Moisture Proof And Mechanically Sound Insulation At All Such Points Along The Cable Run. Laying Of The Cable In The Excavated Trench In A Neat And Orderly Manner With Adequate Slack Provided At Both Ends To Facilitate Making Of Electrical Connections. The Cable To Be Laid Without Kinks, Twists Or Sharp Bends So As To Avoid Mechanical Damage To The Cable Insulation. Filling Of The Trench With Excavated Earth With Proper Compaction Using Manual Labour Along With Requisite Tools And Tackles. Removal Of The Old/Damaged Foot Valve Of Priming Pump Of 2 Hp From The Suction Pipe By Way Of Cutting The Rust Nuts And Bolts. providing and Fixing Of 01 No. New 2.5 Inch Foot Valve Of Standard Make With Appropriate Size Of Flange, New Nuts And Bolts Of Appropriate Size Along With Rubber Gaskets/Packing Of Suitable Thickness So As To Ensure A Leak Proof Joint. The Job Also Involves Cutting Of Rusted/Damaged Flange From The Suction Pipe Piece End And Providing And Welding Of New Flange Of Requisite Size To The End Of Suction Pipe Piece. Lowering Of The Suction Pipe Assembly Along With The Newly Fitted Foot Valve Back Into The Canal To Its Original Position Using And Manual Labour. Securing Of The Pipe In Its Correct Position As Per Original Installation. Testing And Commissioning Of The Priming Pump With The New Foot Valve By Way Of Priming The Pump And Running It On Full Load To Verify Proper Suction, Absence Of Air Leakage At The Foot Valve And Correct Pumping Action. Rewinding Of 2 Hp, 3-Phase, 415V, 50 Hz Priming Pump Motor At Lis Khawas Khan By Way Of Dismantling Of Motor Assembly From Pump Set Using Tools And Tackles And Carriage To Workshop. Stripping Of Old Burnt/Damaged Stator Winding From Stator Slots And Cleaning Of Stator Core And Slots. Rewinding Of Stator With New Standard Copper Winding Wire Of Appropriate Gauge In Same Winding Configuration As Original With New Slot Insulation Liner Paper Of Appropriate Class. providing and Fixing Of New Connecting Leads And Terminal Connections Of Appropriate Size. Impregnation Of Completed Winding With Class B/F Insulating Varnish By Way Of Dipping And Oven Baking. Reassembly Of Motor And Replacement Of Bearings If Found Defective. Fabrication And providing and Fixing Of New Terminal Plate In Place Of Existing Worn Out/Damaged Terminal Plate Of Priming Pump Motor By Way Of Removal Of Old Terminal Plate And Fabrication Of New Terminal Plate From Bakelite Sheet Of Appropriate Size And Thickness. providing and Fixing Of New Isi Standard Brass Terminal Studs, Nuts And Washers Of Appropriate Size And Current Rating. Proper Insulation Of Terminal Connections By Way Of Pvc Sleeving And Ferrules Of Appropriate Size. Reconnecting Motor Winding Leads To New Terminals And Testing For Proper Insulation Resistance And Contact Continuity Using Megger. Back Shifting Of Rewound Motor To Site, Fitment And Testing On Full Load. Complete Job Includes Cost Of All Materials, Consumables Including Rebate On Old/Damaged Components, Carriage Of Material To Site, Labour Charges Of Skilled As Well As Semi-Skilled Labour, Testing And Commissioning Charges At Lis Khawas Khan. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
8.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
9.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
10.
Housing Urban and Rular Development #11066672 Price Bid
Tender For Annual Repair, Maintenance Operation Armo Works Of Civil Electrical Including The Repair And Camc Of Em Equipments At Esis Hospital, Branch Office, Dispensary And Residential Quarters At Margao, Goa, - Epoxy, Grouting Mortar/Admixtures Waterproofing Chemicals Aluminum Sections Float Glass/Mirror Aluminum Composite panels Tile Joint Filler Silicone Sealants Paints Texture Paints Something Polish Melamine Stainless Steel Railings Vitrified Tile Ceramic Tile Cement Gypsum Ceiling Mineral Fibre Tiles Door Accessories C CLASS PIPES (MS/GI) PIPE FITTINGS WELDING RODS RUBBER GASKETS ENAMEL PAINTS PAINT PRIMER ELECTRICAL MCBS/ MCB ISOLATORS/RCCBS/ ELCBS/ RCBOS/ MCB DISTRIBUTION BOARDS/ PRE-WIRED DBS- SINGLE/ THREE-PHASE (VERTICAL & HORIZONTAL- SINGLE/DOUBLE DOOR POLY CARBONATE MCBDB MCCBS CHANGE OVER SWITCH (OFF LOAD/ON LOAD) METAL CLAD SHEET STEEL ENCLOUSER SOCKET/PLUG BOX SFU/PSU HRC/HBC FUSES & BASES AUTOMATIC SWITCHES( BASED) TRANSFER SOLONOID LOAD BREAK SWITCHES FR/FRLS/ FIRE SURVIVAL PVC INSULATED COPPER WIRES/ CABLES (SECURED OR OTHERWISE) MODULAR PLATE SWITCHES AND SOCKETS ELECTRONIC ENERGY METERS SINGLE/ THREE PHASE & TRIVECTOR LUMINARIES PVC CONDUIT (ISI MARKED) STEEL CONDUCT (ERW) (ISI MARKED) FLEXIBLE CONDUIT BAKELITE SHEET TELECOMMUNICATION CABLE TV COAXIAL CABLE CONTROL & INSTRUMENTATION CABLE COMPUTER/DATA CABLE VOLTAGE TRANSFORMERS CURRENT TRANSFORMER MEASURING INSTRUMENTS CEILING FAN EXHAUST FAN/AXIAL FLOW FAN/VENTILATION FAN TAG BLOCK VCB/ HT SWITCHGEAR (11/33KV) ACB (3/4POLE) MV/LV SWITVHGEAR HT/LT CABLE (PVC/ XPLE/ FIRE SURVIVAL) AUTOMATION POWER FACTOR CONTROL RELAY CAPACITORS CABLE GLANDS (DOUBLE COMPRESSION EARTHING LINKS) WITH BI-METALLIC CABLES LUGS/ PVC GLANDS CABLE JOINTING KITS CABLE TRAYS (FACTORY FABRICATED)/RACEWAYS BATTERY (SEALED MAINTENANCE FREE) BATTERY CHARGER DG SET EARTH LEAKAGE RELAY SINGLE PAHSING DEVICE PUSH BUTTONS TIME RELAY DEVICE SELECTOR SWITCHES ROTARY SWITCHES INDICATING LIGHTS TERMINALS STREET LIGHT FIXTURES (HALOGEN/ PL/ METAL. HALIDE/MV/5V) MS SWAGED TUBLAR POLE STREET LIGHT POLES TELEPHONE OUTLETS MOTORS EPBAX SYSTEM & TELEPHONE LIGHTING UNIT UIS PROTECTION STARTERS (SOFT/ DOL/ AUTOMATIC STAR DELTA/ SUBMERSIBLE PUMPS BUTTERFLY VALVES DUAL VALUES PLATE CHECK BALANCING VALVES GLOBE VALVES TEMP/PRESSURE GAUGE WITH ISOLATING VALVE CONTROL INSTRUMENTATION CABLE ACB (3/4 POLE) MCCB MCB MEASURING INSTRUMENTS HRC FUSE & FITTINGS CURRENT TRANSFORMERS CONTACTORS STARTER OVERLOAD RELAYS INDICATING LIGHTS SELECTOR/ TOGGLE/ROTTARY SWITCHES CHANGE OVER SWITCH TIME DELAY DEVICE SINGLE PHASE DEVICE FUSE SWITCHES/SWITCH FUSES/ SWITCHES ISOLATING ELECTRICAL PANEL/ SUB- PANEL AHU PANEL CABLE GLANDS (DOUBLE COMPRESSION EARTHING LINKS) WITH PVC GLANDS/CABLE LUGS ELEVATORS Fire suppression system C CLASS PIPES (MS/GI) PIPE FITTINGS FIRE/CLEAR WATER PUMPPS ELECTRIC MOTORS 2/3/4 WAY SUCTION/ COLLECTION HEAD GM VALVES MS/CI VALVES FIRE HYDRANT VALVES (15 CODE 5290) INLET BRANCH PIPE BREACHINGS/ FIRE HOSE PIPES (IS CODE 636 II) RUBBER PIPE FOR HOSE REFL SPRINKLERS INCLUDING PLATES) (ALL TYPES ROSETTE FIRST AID FIRE HOSE REELS (IS CODE 884) RRL HOSE (IS 636) C.L. BUTTERFLY VALVES WATER TYPE NRVS CL DOUBLE FLANGED NRVS (IS CODE 780) GATE VALVE SPRAY NOZZLE BALL VALVE VIBRATION ISOLATOR SUMP PUMPS/ DEWATERING PUMPS PRESSURE SWITCH PRESSURE GAUGE EXPANSION/ DASH/ANCHOR/ FASTENERS WELDING RODS RUBBER GASKEIS HOSE DRUM MECHANICAL SEAL STRAINER WATER FLOW SWITCH INSTALLATION VALVE CONTROL PROTECTIVE TAPE CL. PIPES CLASS LA DIESEL ENGINE ENAMEL PAINTS PAINT PRIMER CONTROL & INSTRUMENTATION CABLES POWER CABLES PUMP PANELS Cement (Grey) Steel Floor Tiles (Mosaic) ISI marked Floor Tiles (Chequerred) (151 markedonly) C.P. Brass Cock, Pillar Cock, Stop Cock etc. (151 marked only) C.P. Brass Shower Rose 125 mm dia C.P. Brass Towel rail C.P. Brass Flush Valve (ISI Marked) C.P. Brass Waste Coupling Urinal Stalls (ISI Marked only) Squatting Pan (ISI Marked only) P.V.C. Flush Tank (ISI Marked only) Wash Basin (ISI Marked only). Water Closets (ISI Marked only) Kitchen Sink (Fire Clay) (ISI Markedonly) (IS771) G.L. Pipes (ISI Marked only) PVC Tanks (ISI Marked) C.L. Pipes (ISI Marked only) (15:1536) D.L. Pipes Flush Door Shutters (ISI Marked only) Aluminium Door Fittings (151 Markedonly) Oxidised M.S. Door Fittings (151 Marked only) Black Enamelled M.S. Hinges (151) Marked only) Steel Door/Windows Frames Mortice Locks (ISI Marked only) Steel Sectional /Ventilators Windows Particle Board / Plywood (ISIMarked) Aluminium Extruded Body Diecast Door Closures (ISI Marked only) (IS: 3564) Stone Ware Pipes Grade A (ISI Marked only) Centrifugally Cast Soil Pipes (15 Marked only) C.I. Rain Water Pipes (ISI Marked only) UPVC Rain Water Pipes (ISI Markedonly) (IS: 13592) Steel Tubes for Structural purpose (151 Marked only) (IS: 1161) Manhole Covers (ISI Marked only) (IS 1726) Water Proofing Compound. (ISIMarked only) Ceremaic Floor Tiles Ceremaic Wall Tiles Putty (ISI Marked only) (IS: 419) Anodized Aluminium Section (151) Marked only) Factory made concrete blocks White cement (ISI Marked only) Glass sheet (Float Plain) (ISI Markedonly) PTMT Ball Cock (ISI Marked only) PTMT Accessories (ISI Marked only) G.L Fittings Clamps for pipes Gate Valves (ISI Marked only) CPVC Pipes External Premium Acrylic Paint External Smooth Acrylic Paint Acrylic Plaster Interlocking Paver Blocks Vitrified floor tiles Oil Bound Washable Distemper/ Acrylic distemper Cement Primer Red Oxide Zinc Chromate primer Plastic Emulsion Paint Synthetic Enamel Paint Pigment Plaster of Paris Epoxy Paint Plastic seat with lid PVC shutters & frame PVC Rigid Pipes RMC Plant APP Sheet for water proofing treatment Acrylic Polymer Rusticide Passivator Water Proofing Compound
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
11.
Educational and Research Institute #11059846 Price Bid
Tender For Equipment; Purchase of Equipment: Rotary evaporator with accessories Rotavapor V-Condenser P+G assembly Cooling capacity1500cm/hour with Drive unit 3 inch Dark Segment Display for Rotation speed, lift position and heating bath temperature (set and actual value) displayed on the Heating Bath Base. Allows user to monitor all parameters at a glance., Motor lift with 10-330 RPM, Limit position detection adjustment range Vertical 180mm, Immersion Angle 15-52.5° (Adjustable with 7 Stages), Flask Sizes Uses from 50ml....3000 ml Capacity Safety Stop: Automatic operation stop by power failure, Lifts flask automatically out of heating bath Manually adjustable via button within a range of 100 mm prevents glass breakage and damage to bath pan Patented multifunctional Combi-Clip for evaporating flask fixation and removal, as well as vapor duct release Allows one handed flask removal 1 liter evaporating flask NS 29/32 and 1 liter receiving flask, Protection Class IP42, CE CSA & ISO 9001 Certified Lift height indication Position is digitally indicated on display of heating bath and Key button Lock function Heating Bath, Digital Display heating bath temperature range of up to....95°C Kettle Connection: Cordless bath Allows easy emptying and refilling of bath without unplugging Infrared communication: Transition of heating bath data to interface Maximum Bath Capacity 4.2 Litre, Digital temperature display allows adjusting set temperature and indicates actual temperature Over Heat Protection: Cut off power when actual temperature exceeds set temperature or by rapid temperature increase Protection Class IP21, CE/ISO 9001 Certified, Heating Power 1300W Vacuum Controller, 3 Dark Segment Digital Display controller indicating, adjusting and controlling the vacuum. Special features like a) measure and display the pressure, b) Regulate the vacuum pump speed & c) Start/Stop the vacuum pump Manually regulate the system leakage using a needle valve, Two operating modes (manual, timer), Measuring Range: 1400-0 mbar, Control range: 1100-0 mbar, Hysteresis Automatic or 1 - 500 mbar Measuring Accuracy: +2mbar (+)- after calibration at constant temperature Protection Class IP44, CE/CB/UL/CSA Certified, Along with woulff bottle for Trap Vacuum Pump,- 100% Solvent recovery DC motor Brushless vacuum pump pump for reusable Speed control chemical resistant PTFE diaphragm DC motor Brushless vacuum pump Achieve more than 90% solvent recovery and reusable using interface, Vacuum generation optimally suited to work with the Rotavapor. Final vacuum: 13 mbar (with Gas Ballast), Flow Rate: 1.3 m3/h. InOn/Off.control the pump is automaticallız turned On and Offseis the interfece On/Off communication
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
12.
Drinking Water Supply and Sanitation #10956801 AOC
Tender for Repair And Maintenance Works To Vvg Nagar Panchayat Union Middle School-- 1 Dismantling and clearing away existing for Plain Cement Concrete including cost of conveyance and labour charges at site, other incidental charges etc., complete 2 Dismantling and clearing away existing for Doors and windows including removal of frames, hinges and fastenings including cost and conveyance at site of labour charges etc. complete 3 Dismantling and clearing away existing Damaged Brick work in Cement Mortar including cost and conveyance labour charges and other incidental charges etc., complete as per std. Specification. 4 Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9 X 43/8X 2 3/4 including finishing, curing, etc., complete complying with standard specification 5 Supplying and erecting centering for vertical plain/ RCC concrete walls of supply channel, retaining wall etc upto 90Cm height with necessary supports,all cross bracing with mild steel size of 90cm x60 cm and gauge BG 10 stiffened with welded mild steel sheet angles of size 25 mm x25 mm x3mm for bearing laid silver Oak/ Country wood joist of size 7.50 cm x5.0 cm spaced @ about 90 cm C/C and supported by Casurina props of 10 cm to 13 cm spaced @ 75 cm C/C etc,, complete complaying withstandered specfications and as directed by the departmental officers. 6 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - 7 Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. 8 Plastering with cement mortar 1:5mix 12mm thickincluding cost and conveyance of labour charges and other incidental charges etc., complete as per std. Specification. 9 Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum 10 Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 11 Dadooing walls withGlazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. 12 Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement 13 Supply and fixing in position of white glazed of 20” size Indiantype water closet with ‘p’ or ‘S’ trap and a pair porcelain foot rest toslaps set in bricks jelly cc 1:4:8100mm thick using 20mm thick jelly and finishing to sludge out any leakage and defaultincludingcost and conveyance of all materials labour charges for fixing inposition and other incidental charges etc., complete as directed by dept. officers. 14 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colour for PVC concealed light / fan point (6Points Per Coil) (For Rooms like Bath, Toilet & Pump room etc..) (SD-26). 15 Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3 mm thick Hylem sheet cover for 5 A3 pin non inter locking CS Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. [SD38] 16 Supply and fixing of4-18WLED tube with fitting inclusive of all charges 17 Supply and delivery of the following PVC pipes and specials including cost of materials to site, loading & unloading and conveyance charges and other incidential charges etc., complete. 18 160mm dia PVC Pipe 6Ksc 19 160mm dia PVC Elbow 20 160mm dia PVC Bend 21 160mm dia PVC Tee 22 32mm dia PVC Pipe 10 KSC 23 32mm dia PVC Coupling 24 25mm dia PVC Pipe 10KSc 25 25mm dia PVC Elbow 26 25mm dia PVC Coupling 27 20mm dia Brass Tap 28 Supply, delivery and fixing of 2000Lit Capacity of HDPE Tank as per IS 12701/1996 including loading, unloading, transporatation and labour charges for fixing of the GI Pipes and specials for pipe connection works including cutting and threading charges and inclusive of materials cost, labour conveyance hoisting and fixing charges etc., complete as directed by Departmental Officers 29 FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers 30 Plain Cement Concrete 1:2:4 (one cement, two fine aggregates & four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per std specification 31 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter. (PWD 2023-24 Pg No:43 M-0391 ) 32 Supply and fixing of M.S Grills with Ventilator arrangements with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 33 White washing two coats using best shell lime including, cost and conveyance, labour charges and other incidentalcharges etc., complete as directed by Deptl.officers. 34 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of Paris, putty, wherever required etc., complete complying with standard specification. 35 supply and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD 110
Contract Date: May 02, 2026 Contract Value : 26.92 Lakh
Local Bodies No of Bidders 2
13.
Housing Urban and Rular Development #10908306 AOC
Providing Basic Amenities And Beautification Of Dargoba Temple Campus, At-Dargoba Mandir, Pare, Tal-Khanapur, Dist-Sangli.-Cubic Metre Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Cubic Metre Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (upto all leads and lifts) By Mechanical Means Cubic Metre Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. with fine aggregate (Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Providing expansion joints in reinforced cement concrete framed structure (exterior column) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and 1 milimetre thick stainless steel plate and finishing, excetra complete. (For Ground Floor) Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixe excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete.With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) using ARTIFICIAL SAND). Providing and laying in situ M-25 cement concrete of trap / granite / quartzite / gneiss metal with 15 percent plum of trap stones for retaining walls and jetty, excetra including necessary formwork, compacting, curing, bailing out water manually in tidal range, excetra complete. Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. For Ground Floor) Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water, striking joints on unexposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Providing and fixing mild steel grill railing weighing 20 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For Ground Floor) Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete. Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In- Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Providing coursed rubble masonry first sort of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints on the inside when plastering is to be done, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying rubble stone flooring laid in cement mortar 1:3 as per drawing and technical specifications, excetra complete. (using ARTIFICIAL SAND). Providing sills of granite 20 milimetre to 25 milimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For Ground Floor) 124610.70 Providing and fixing in position guard railing as per Drawing Number 15 type C dated 20-4-1979, with three rows of 40 milimetre diameter galvanised iron pipe 30 centimetre apart and fixed in mild steel channels of section 100 milimetre X 50 milimetre X 6 milimetre spaced 2.5 metre center to centre, 1:2:4 cement concrete bedding of size 45 centimetre X 30 centimetre X 30 centimetre as per detailed drawing, with 3 coats of approved yellow and black paint including necessary excavation in any strata. Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For Ground Floor) Providing and applying priming coat over new / old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matters and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding, excetra complete. (For Ground Floor) Providing and applying two coats of lead / zinc base oil paint / bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface, excetra complete. (excluding primer coat). (For Ground Floor) Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing auto closing pillar cock of pressmatic tap of approved make including all fixtures, fittings, excetra complete. (For Ground Floor) Providing and fixing 450 milimetre X 550 milimetre size superior type belgium mirror with 16 milimetre diameter nickel plated towel rod, excetra complete. (For Ground Floor) Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing 15 milimetre diameter ball cock medium type with polyvinyl chloride float including sockets and necessary fittings and tested as per municipal requirements, excetra complete. (For Ground Floor) Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor) Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Providing and fixing in position (as per Indian Standard 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With colour anodising without box. (For Ground Floor) Providing and fixing 30 milimetre thick polyvinyl chloride flush L door shutter consisting of panel of hollow polyvinyl chloride profile of 20 milimetre thickness consisting frame made out of mild steel tubes of 19 gauge thickness and size of 19 milimetre X 19 milimetre inserted inside the hollow section of stiles rails top and bottom rails and two milimetre X 19 milimetre mild steel tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5 milimetre X 2) thick X 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 milimetre thick termite proof waterproof plain / prelam poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening excetra Complete as per direction of Engineer in-charge, manufacturer’s specification and drawing. (For Ground Floor) Providing and fixing Orissa type colour glazed earthenware 625 milimetre X 450 milimetre water closet including trap, cast iron soil and vent pipe upto the out side face of wall including 100 milimetre diameter cast iron plug bend, 15 milimetre thick 10 litre polyvinyl chloride flushing cistern with all necessary pipe connection, excetra complete. (For Ground Floor) Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor) Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor) Providing and fixing Ivory glazed earthenware full stall type urinal with poly vinyl chloride flushing cistern of 5 litres capacity with fitting inlet pipes and stop tap brackets for fixing the cistern 32 milimetre diameter poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection upto the outside face of the wall. (For Ground Floor) Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. Providing first class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 including scaffolding, racking joints pointing in cement mortar 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25- 30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturers product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor) Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, excetra) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Providing and applying plastic emulsion paint of approved quality, colour and shade to new surfaces in three coats including scaffolding, preparing the surfaces (excluding primer coat), excetra complete. Providing and fixing Indian teak wood eaves boards 15 centimetre wide and 25 milimetre thick plain decorative type including scaffolding and painting with two coats, excetra complete. (For Ground Floor) Providing and laying cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete arches with skew backs as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed)With fine aggregate ( Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying rough shahabad stone flooring 50 milimetre to 60 milimetre thick and of required width in plain / diamond pattern on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor) Providing and applying spray plaster made with finelly graded marble and quartz in 2 milimetre thickness in two coats using putty knife or trowel to newly plaster fairly even surface after minimum 30 days gap, in all positions including finishing the surface using zero number sand paper or fine emry paper gently level the area by moving paper in round circles removing the dust and clean the surface with dry cloth and scaffolding including all materials and labour, excetra complete. (For Ground Floor) Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing groove to required size at specified location as directed by Engineer, at junction of brick masonary wall and reinforced cement concrete beams or column, at junction of composite masonary, including scaffolding, finishing curing, excetra complete. Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor) Providing and fixing false ceilling of plain asbestos cement sheets 4 milimetre thick with teak wood beadings 45 milimetre X 12 milimetre thick frame work of counrtry teak wood battens of size 70 milimetre X 60 milimetre at 1.00 metre center to center including scaffolding, if necessary, all iron work and painting (visible surfaces) to asbestos cement sheet and beading in two coats, excetra complete. excluding teak wood runner to be paid seperately). (For Ground Floor) Providing and laying in position flooring of telephone black amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) using ARTIFICIAL SAND). Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 milimetre thick and 75 centimetre high vertical support for Kadappa at one metre center to center of 25 milimetre thick both side polished Kadappa middle shelf and bottom of 20 milimetre thick one side polished Kadappa with facia patti of 20 milimetre X 50 milimetre Kadappa including all material, labour, cutting, fixing with cement mortar and araldite, all material labour cutting fixing with cement mortar and araldite curing polished and cleaning excetra complete. (For Ground Floor) Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Providing and laying in trenches 15 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Providing and laying ceramic tiles of having sizes 30 centimetre X 45 centimetre and confirming corrosponding Indian standared for dado and skirting required position with ready made adhesive mortar approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets union nut complete. (For Ground Floor) Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor) Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor) Providing and fixing poly vinyl chloride rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 milimetre to 2.7 milimetre confirming to Indian Standard : 13592-1992 including proper rain water receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall affixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete. (For Ground Floor) Total-A Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand Compressive Strength of Cement Concrete Cube Sieve Analysis Test for Metal below 40 milimetre Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre Flekiness & Elongation Test for Metal below 40 milimetre Concrete Mix Design (with all tests on basic materials) for Grade M-25 Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks Compressive Strength of Cement Mortar Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre) Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar above 16 milimetre) Liquid Limit & Plastic Limit for Plinth Filling Soil/Murum Compaction test (Proctor Density) Soil/Murum Compaction test Density by Sand Replacement Method Concrete Mix Design (with all tests on basic materials) for Grade M-30 Thickness, Mass per Running Metre of Aluminium Section Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles Water Absorption, Modulus of Rupture Test for Natural stone/Kota/Marble/Granite/Tandoor etc) Wood density ,Moisture content Test Total B Total A+B
Contract Date: Apr 29, 2026 Contract Value : 2.65 Crore
Government Departments No of Bidders 1
Maharashtra View Result →
14.
Defence #10861312 AOC
Tender For Repair/ Maintenance Of Ht Cables, Switch Gears And Relays Incl Connected Items Under Ge (W) Colaba.; 1 Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamberof HT 11KV, panel boardand carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge.(Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B)and HTtape and test with High Voltage(DC)and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamberby checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CTs and insulatorsand HT Tape.(iii) Inspecting/cleaning/overhauling meteringchamberby checking ofentire wiring system, all meters, selector switches, control fuses and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. 2 Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 3 Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare partssuitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge. 4 Isolating Contacts flat type 5 Vaccum InterupterVG2 6 Insulating Rod 7 Closing coil 110V /24V DC 8 Tripping Coil 110V /24V DC 9 Spring Charging Motor 110V-230V AC/DC 10 Breaker Auxiliary Switch 6NO +6NC 11 Motor Cut-off switch 12 Main Drive Shaft assembly 13 Trip Fork Linkage Assembly 14 Rachet Wheel 15 Pin for Rachet 16 Handle Block Assembly 17 Closing coilassembly without coil 18 Trip coilassembly without coil 19 Motor cutt offLever assembly 20 Trip Proper support assembly 21 Release lever 22 Pin for Release lever 23 Auxiary switch drive Assembly 24 Charging Pawl 25 Buffer for Spring 26 Over Rid Stop 27 Over Rid Stop Pin 28 24 Pin Plu and Socket Assembly 29 Bus Bar Spout Insulator with CC parts for R Phase 30 Bus Bar Spout Insulator with CCparts for Y Phase 31 Bus Bar Spout Insulator with CC parts for B Phase 32 Circuit Spout Insulator with CC Parts 33 3Phase Spout Insulator assembly Bus bar /Circuit side. 34 Half Collar (Pair) 35 Raising and lowering Handle 36 TNC Switch,16Amps Recom 37 Ammeter,digital type,DM3110 Schneider 38 Voltmeter,digital type DM3210 Schneider 39 Multifunction meter digital typeEM6400NG Schneider 40 Indicating Lamps 24/110V DC LED type 41 Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts ACand replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) 42 Material and labour for painting of HT VCBcapacity 250/350MVA,11KV, 400/630/800Amps, with onecoat of synthetic enamel paint over a coat ofred oxide primerafter cleaning, scraping, and filling ofcavitiesfor out side surface and in side surfaceof VCB and writing the details such as MES No/ SM No etc on the new metallic plate of size 30x15cm and fixng the metallic plate firmy on VCBall as specified and as directed by Engineer-in-charge. 43 S&F, testing commissioning ofcurrent transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge. 44 T&P for Testing of primary injection by artificialloadthroughCT’s, on each multiple settingofovercurrent & earth fault relay, testing polarities, ammeter and selectorswitchandasdirected by Engineer-in-Charge. 45 T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. 46 Repair/Overhauling Indoor type, 11 KV, SF 6, RMU Panel and carrying with following and all as specified and directed by engineer in Charge.Note :- (i) Including fixing ofspare parts to function RMU smoothly and rate to be included.Notes :-Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.(ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.(v) Overhauling/testing of Metering Panel with PT(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete.(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.(viii)Spraying two coat of anti track paint on CTs.(ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels. 47 S&F 11 KV, SF 6,RMU Panel Spring Charging Motor, with complete mechanisim 230/110/24 Volts of existing make. 48 S&F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed. 49 Repair/ MaintenanceBattery Charger Circuit 240 V AC to110 V DC 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed. 50 Repair/ MaintenanceDC to DC Converter 110 V DC to 24 Volt dc20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed 51 S&F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed 52 Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacitysuitable for VCB,s /OCB in existing panel including hard ware,wiringand all as directed. 53 T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 54 T&P for route tracing ofHT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 55 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 56 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified. 57 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 58 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified. 59 Supply, Installation, testing ON LOAD & commissioning of Compact motor protection relay flush mounting with display MM-10 with 110-240V AC/DC aux supply, having following protections with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system making good to the disturbed surface all as specified and directed.(a) Thermal over load and short circuit . (b) Earth fault and phase loss, unbalance, phase reversal.(c) Prolong starting, locked rotor and last trip data recording. 60 Supply, Installation, testing & commissioning of Under Over Voltage relay single phase system voltage 20-110 Volt AC/DC with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system including making to the disturbed surface all as specified and directed. 61 Material and labour for loading into truck of old OCB/VCB with the help of Crain and shifting from site to store/ substation premises and unloading complete all as specified and directed. 62 Material and labour Disconnecting, dismantling & restablising the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 63 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out completein soft/loose soil all as specified. 64 All as perabove item No.63.00 above but in hard/dense soil. 65 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed. 66 Supply and providing sand/stone dust for sand cushioning for cable protection orfilling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thicknesswill be measured. 67 Supply and providingunreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) ofsizes Class HVPtype I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. 68 Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. 69 Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified. 70 Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil 71 Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed. 72 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 240 sq. mm X 3 core all as specified and as directed. 73 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. 74 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed. 75 Manufacturing, supplying and fixing at various sub stations for SOP (Standard Operating Procedure) for VCB/ RMU Operation on farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved . Letter,symbols, MES Logo ,borders etc.on A-1 Size paper all as required colour scheme in all respects as per direction of Engineer-in-charge. 76 T&P for fault finding, confirmation and route tracing on LT cables of any size and any length with fault detective machine by thumping method and suitable high voltage and all as and directed by Engineer-in-charge. 77 Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size3.5/4 core 50 Sqmmcomplete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra. 78 All as per aboveitem No 77.00 herein before but cable 3.5 core 70 Sq mm 79 All as per aboveitem No 77.00 herein before but cable 3.5 core 95 Sq mm 80 All as per aboveitem No 77.00 herein before but cable 3.5 core 120 Sq mm 81 All as per aboveitem No 77.00 herein before but cable 3.5 core 185 Sq mm 82 All as per aboveitem No 77.00 herein before but cable 3.5 core 240 Sq mm 83 Material & Labourfor repairs/ Overhauling/Servicing to ExistingLT electric panels by takingshut down from appropiate authority includingT&P for Attending Faults/Trippings and rectifieng /repairingthe faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCBs/ACBs /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut boltsand all as specified and directed by Engineer-In-Charge. (i)Tightning the loose connectionsand cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colourandtesting the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paidseparately under relevant items of this schedule.) 84 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge. 85 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 240Sqmm x 3.5 corecomplete all as specified and directed by Engr-in-charge. 86 Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhaulingof spring drive mechanism, coil, auxiliary switch includingsetting of over loadcoil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspectingmale and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective positionandtesting complete all as specified and directed by Engineer-in-Charge. 87 Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare partssuitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge. 88 Shunt Trip Device 89 Closing coil assembly 90 Mismatch Prevention Device 91 Moving contacts assembly 92 Fixed Contact assembly 93 Auxiliary Switch 94 Arc chut with hardware 95 Current Transformers 630A/5A. 96 Current Transformers 800A/5A 97 Current Transformers 1200A/5A 98 Dismantlingof old damaged Meters and Supply & fixDigital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/ Elmeasure. 99 Dismantlingof old damaged MetersSupply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type andall as specified and directed. Make:AE/MECO/ Elmeasure. 100 Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 101 S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge. 102 Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 103 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel as required for retrofit after wiring work complete all as specified & directed. 104 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel,SMARTCOMN EMS Energy Management System software with multiple features suitable for minimum 10 meters at existing dashboard/ computer and shall capture and provide following data for 12 months peroid:1) 30 min instantaneous data from all the meters for seven parameters- cumulative Energy, Power, Current, Voltage, Power factor and frequency. 2) Multiple combination of device and parameters for analysis and monthly and quaterly billing survey dattion a for cumulative energy and max demand.3) Specific Energy Consumption (SEC) Report and assess to features defined by user levels.4) Monitor ON, OFF, TRIP, Ready to close status of circuit breaker through E&As UNCO Module with on premise solution. 5) Provision for Breaker ON & TRIP counter, Last 20 trips date & time6) Email and SMS notification & Excel reports with charts. 105 M&L for Maint of MQTT GPRS Converter Outdoor (LoRa) Long Range Communication Accumulator suitable for communicating with multifunctional digital Meter with LoRa communication protocol and the data transfer to the software complete all as required on existing ground position as specified and directed. 106 M&L for Maintand recharge topup for 12 months peroidof 4G/5G Router all asrequired as on existing ground position including necessary data cable (low impedance ) suitable to existing ground position including necessary data cable (low impedance) suitable to transmit data of energy meter port and CAT-6 (Patch Cord) all as directed by Engr-in-Charge. 107 M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge. 108 M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected toGI earth strip 32mm x 6mmearth leadby means of bolts,nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/panel board , all as specified and shown in MES schedule Electrical Plate No-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoaldust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note : Value of earth resistance shall not be more than 2 Ohm. 109 M&L in repairs galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop all as specified and directed by the Engineer-in-Charge. 110 Supply and fixing substation insulation rubber floor mats not less than 2.5 mm thickness suitable for operation on 11 KV panels confirming to IS 15652 : 2006 all as specified and directed by Engineer-Incharge.
Contract Date: Apr 27, 2026 Contract Value : 32.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
15.
Educational and Research Institute #10838989 Price Bid
Supply Of Medicines/Items Under M-Aay And Rghs Scheme (Rate Contract For 2 Years) , Abdominal Binder L Size , Abdominal Binder Xl Size , Abdominal Binder Xxl Size , Bipolar Forcep , Bone Wax , Codon Filter , Multi Firecurved Cutter Stapler 4 Curvlinear Rows Of Stapalwithsingal Cut Line ,40Mm Stapal Line , Corrugated Drain , Cvp Manometer , Dental Burr 701-702-703 (Cross Cut Tappered Fissure) , Dextran 40 , Disposable Gown , Dlt 35F Left , Dlt 37F Left , Dlt 39F Left , Drill Beat Small Size , Ecg Electrodes, Adult , Endoscopic Linear Cutter 45 Mm Stapler Line ,42 Mm Cut Line ,45 Degreebilatral Articulation With 360 Degree Rotation Usfda Approve , Endoscopic Linear Cutter 60 Mm Stapler Line ,57 Mm Cut Line ,45 Degreebilatral Articulation With 360 Degreerotation,440 Mm Shaft Length.Usfda Approve , Endoscopic Linear Cutter Cartridge 60 Mm Stapleline , Staple Height 1*1.5*2 Mm ,Compatible With 60 Mm Endoscopic Linear Cutter. Usfda Approve , Endoscopic Linear Cutter Cartridge 45 Mm Stapleline ,42 Mm Cut Line.Staple Height 1*1.5*2 Mm ,Compatible With 45 Mm Endoscopic Linear Cutter. Usfda Approve , Emergency Percutenous Tracheostomy Set , Et Tube Cuffed All Sizes , Et Tube Uncuffed All Sizes , Ethibond 1-0 40Mm Code Nw679 , Extension Line For Blood Set , Extension Line Iv Line , Feeding Ryle’S Tube 14G , Feeding Ryle’S Tube 16G , Flexo Metalictube8.0Fcuffed , Flexo Metalic Tube 7.5F Cuffed , Flexo Metalic Tube 8.5F Cuffed , Freka Tube No. 12, 14 , Gauz Than 60X20 , 8F Chemo Port Valved Catheter With Intermediate Size Port With Small Septum And Silicon Filled Suture Holes,Mricompatible ,Peel Apart Percutaneous Introducer System , Pice Line 4F, , Piceline5f , Harmonic Probes 9 Cm Us Fda Approve , Harmonic Probes 14 Cm Us Fda Approve , Hiv-Kit Premium(Universal Protection Kit Premium Quality) For Positive Patients (Disposable O.T. Gown & Kit) , Head And Eye Shield -Disposable Used Without Helmet , Icdt 28,(Internal Drain) , Icdt 32 (Internal Drain) , Inj. Isolyte M , Inj. Mephentermin , Inj. Paracetamol 100Ml Infusion , Inj. T.P.N. 1440 Ml , Inj. T.P.N. 1920 Ml , Inj.Succinycholin , Ligating Clip 100 , Ligating Clip 200 , Ligating Clip 300 , Ligasurecurvad, Small Jaw, Open Sealer/Divider Hand Probe , Nylon 1-0 , Polypropylene Loop No.1 , Lower Limb Stockings All Sizes , Lp Needle 18G , Lp Needle 20G , Lp Needle 22G , Lp Needle 23G , Macintosh Sheet 190Mtrs. Or More , Male To Male Connector , Mapelson C Circuit Adult , Megallis Forceps ( Adult& Pediatrics) , Micro Volume Set , Mold (Position And Fixsation Device) , Nasal Oxygen Catheter Adult , Nasal Oxygen Catheter Pediatrics. , North Pole Tube 7.5F, 8.5F , Nylon 1-0 Rc , Nylon 2-0 Rc , Nylon 3-0 Rc , Nylon 6-0 , Nylon 8-0 , Paraffin Gauge Dressing Sterilised Ready For Immediate Use, A Non Adhesive Open Mesh Dressing , Polydiaxanone 6-0 Rb , Polydiaxanone 2-0 Rb , Polydiaxanone 3-0 Rb , Polydiaxanone 4-0 Rb , Polydiaxanone 5-0 Rb , Polydiaxanone 5-0 Dn , Polydiaxanone 6-0 Dn , Picline 4Fr S/L (Picc) With Groshong Valve Silicon Material With Mi Only Saline Flush , Plain Rubber Catheter Nil , Pressure Bag Leak Proof , Pressure Monitoring Line 200Cm , Polypropylene 1-0 Rb , Polypropylene 2-0 Tc , Polypropylene 2-0 , Polypropylene 2-0 Tc , Polypropylene 3-0 , Polypropylene 4-0 , Polypropylene 5-0 , Polypropylene 5-0 , Polypropylene 6-0 , Polypropylene Mesh 7*15 , Polypropylene Mesh 15*15 , Pvc Suction Tubing, 12.5Mm , Safe Step Neddle For Chemo Port (Safety Enable Wingles Design Huber Port Access Needle 20G 1 Inch With Transparent Comfort Pad) , Silk 1-0 Cb , Silk 2-0 , Silk2-0 Cb , Silk 2-0 Rb , Silk 3-0 Rb , Silk Reel 0 , Silk Reel 1-0 , Silk Reel 2-0 , Silk Reel 3-0 , Skin Grafting Blade , Skin Stapler , Nylon 1-0 , Nylon 2-0 , Spirometer , Stapler Remover , Steridrape , Stoma Bag Three Piece Set Disc, Bag, Clip 55Mm , Stoma Bag Three Piece Set Disc, Bag, Clip 70Mm , Straight Connector. , Strenal Closure Rim , Surgipad 10X10 , Surgipad 10X20 , Sutu Pack 3-0 Sw212 , Sutupack 1-0 Sfs214 , Sutupack No. 4 Sw218 , Sutupak 2-0 Sw213 , Swan Gage Catheter 7Fr , Syringe 20Cc , Syringe 50 Ml With Luer Lock , Syringe 50Cc , T. Connector , T. Piece For Venturi To Fit Et Tube , Tegaderm , Therabite Device (Mouth Opening Device , Thoracic Cathter All Sizes , Three Way Stop Cock , Tracheoesophageal Voice Prosthesis 8 F(Provox/Bloom Singer) Sterile 17Fr/22.5 Fr Voice Prothesis With 1 Sterile Pharynx Made Ogtranspectrent Thermoplastic, 1 Stocile Puncture Xleedke Made Of Surgicla Ss 1Stolieguuidekeiremde Of Pse. Colored Fluoro Plastic, 1 Sterif Puncture Dilator Made Ogpse, Colredfluoro Plastic, 1 Sterif Puncture Dilator Made Og Thermoplastic Elastomer And Polypropylene With 10 Adedvioce Pros Thesis And 1 Nlosterif Brush , Tracheostomy Tube All Cuffed , Transducer Dom With Flusing Device , Transpore 3 , Tripple Lumen Catheter ( Adult) , True Cut Biopsy Gun 16G , True Cut Biopsy Gun 18G , True Cut Biopsy Gun 20G , True Cut Biopsy Needle , Umblical Cotton Tape , Upper Limb Stockings All Sizes , Vaccume Suction Drain20 , Vaccume Suction Drain 10 , Vaccume Suction Drain 12 , Vaccume Suction Drain 14 , Vaccume Suction Drain 16 , Vaccume Suction Drain 18 , Venoline With 3 Way 50Cm Long , Ventilator Circuit , Vicry 3-0 1/2 Circle 25Mm Rb Code2356 , Vicryl 3-0 20Mm 1/2 Circle Code Vp2437 , Vicryl 3-0 Rapid Cutting Sfn2732 , Winged Infusion Set Port Needle , Universal Drape(4*2 Drape Sheet ) , Powered Intra-Luminal Staplers With Curved Shaft Anvil Detachable 29 Mm, 3 Row Staple Line With Adjustable Staple Height (1.0-2.5Mm), Longer Staple Leg 5.5Mm-Non Slip Grip Surface . , Universal Cutter 6 Row Cartridge -55Mmclosed Staple Height Of 1.5Mm/1.8Mm/2Mm , Linearcutter 4 Row -80Mm Cartridge,Tristaple Gia 80Mm Open Linear Cutter Reload Cartridge Black/Purplewith Varied Staple Height ,Tristapletecnology. , Universal Cutter 6 Row Stapler -55Mmclosed Staple Height Of 1.5Mm/1.8Mm/2Mm , Linearcutter 4 Row -80Mm Stapler,Tristaple Gia 80Mm Open Linear Cutter Stapler With Varied Staple Height ,Tristapletecnology Both Side Firing , Sealing Hemo Patch Medium 45*45Mm , Sealing Hemo Patch Small 27*27 Mm , Wound Protector With Double Ring In Large In Size 9-14Cm Usfda Approved. , Proximate Intra-Luminal Staplers With Curved Shaft Anvil Detachable 25Mm, 3 Row Staple Line With Adjustable Staple Height (1.0-2.5Mm),Longer Staple Leg 5.5Mm-Non Slip Grip Surface . , Proximate Intra-Luminal Staplers With Curved Shaft Anvil Detachable 29Mm ,3 Row Staple Line With Adjustable Staple Height (1.0-2.5Mm),Longer Staple Leg 5.5Mm-Non Slip Gripsurface . , Proximate Intra-Luminal Staplers With Curved Shaft Anvil Detachable 33 Mm ,3 Row Staple Line With Adjustable Staple Height (1.0-2.5Mm),Longer Staple Leg 5.5Mm-Non Slip Gripsurface , Arthoscopy Drape Size 160*280Cm , Elastic Aperture ;5Cm Diameter Shoulder Drape – Head Sheet Size ;1.25Cm*16M, Adhesive Stripe 4Cm*1.5M, U Sheet Size :2*1.5M , Bone Cement 20 Gm With Disposable Sterile Cement Gun/ Syringe Kit With Low/High Viscosity , Bone Cement 40 Gm With Disposable Sterile Cement Gun/ Syringe Kit With Low/High Viscosity , Bone Wax , Cautery Plate , Full Gown S (Disposable , Wrapped Around ,With Three Handtowelandcuff ) , Fullgown M (Disposable , Wrapped Around ,With Three Handtowelandcuff ) , Full Gowns L( Disposable , Wrapped Around ,With Three Handtowelandcuff ) , Fullgown Xl(Disposable , Wrapped Around ,With Three Handtowelandcuff ) , Disposable Incise Skin Drape Medium ( Made Upof Polyester Film With An Acrylic Adhesive That Contains A Complex Of Iodoform (N-Vinyl-2- Pyrrolidine )With A Iodine Concentrationof0.092Mg Iodine /Cm2film Should Be Breathable And Comfortable To Skin Compatible With Povidone And Chg Skin Preps Iodine Form The Drape Should Be Present In The Deepest Skin Layers (1000 Microns Depth ) Where Hair Follicles Exist Apart From Killing Microbes On The Skin Layer Product Should Be Registered As A Class D Medical Device With Cdsco India Since It’S An Antimicrobial Product It Should Be Gamma Sterile And Us-Fda Approved Size Shouldbe 34Cm*35Cm (Adhesive Area ) , Disposable Incise Skin Drape Large ( Made Upof Polyester Film With An Acrylic Adhesive That Contains A Complex Of Iodoform (N-Vinyl-2- Pyrrolidine )With A Iodine Concentrationof0.092Mg Iodine /Cm2 Film Should Be Breathable And Comfortable To Skin Compatible With Povidone And Chg Skin Preps Iodine Form The Drape Should Be Present In The Deepest Skin Layers (1000 Microns Depth ) Where Hair Follicles Exist Apart From Killing Microbes On The Skin Layer Product Should Be Registered As A Class D Medical Device With Cdsco India Since It’S An Antimicrobial Product It Should Be Gamma Sterile And Us-Fda Approved Size Shouldbe 56 Cm *45Cm (Adhesive Area ) , Mop – Ultra Low Fibre Sheding,Ultra Fast Adsorbant ,With Radio Opaque Thread , Disposable Plane Sheet , Disposable Syringe For Cement Gun , Encore Gloves No. 7.5 , Encore Gloves No. 7 , Encore Gloves No 6.5 , Nylon 10-0 , Polyester No-2 , Polyester N0-5 , Fiber Tape , Fiber Wire All Size , G Dress - 10( 8.5Cm*6.5Cm ,Pad Size -3Cm*5Cm ) Comfy, Non Woven ,Strechable ,With Non Sticky Pad , G Dress - 15(14Cm*7Cm , Pad Size -3*10Cm ) Comfy, Non Woven ,Strechable ,With Non Sticky Pad , G Dress - 20 (20Cm*10.5Cm ,Pad Size -4Cm*16Cm) ,Comfy, Non Woven ,Strechable ,With Non Sticky Pad , G Dress - 25 (25Cm*10.5Cm ,Pad Size -4Cm*21Cm) ,Comfy, Non Woven ,Strechable ,With Non Sticky Pad , G Dress – 30 (30Cm*10.5Cm ,Pad Size -4*26Cm ,) Comfy, Non Woven ,Strechable ,With Non Sticky Pad , Hipu Drape Size :240*225Cm, U Cut 20+30Cm ,One Cotton Sleeve , Head Sheet:240*200Cm With Adhesive Strip , Iitv Cover(C-Arm Cover) , Knee O Drape Size 240*340 Cm ,One Lay Sheet 160*100Cm, One Cotton Sleeve , Aperture 5Cm , Bilateral Knee O Drape Size 240*340 Cm ,Two Aperture Dia 5Cm , With Two Leg Halders , Passport Cannula Silicon 6 , Passport Cannula Silicon 8 , Antibactirial Coated With Triclosan Polyglactin910suturessizes 2-0 , Antibactirial Coated With Triclosan Polyglactin910sutures Sizes 0 , Antibactirial Coated With Triclosan Polyglactin910sutures Sizes 1-0 , Antibactirial Coated With Triclosan Polyglactin910sutures Sizes 3-0 , Porous Tri Calcium Phosphate Bone Block , Porous Tri Calcium Phosphate With Hydroxyapatite (G Bone)- Bone Granules,Bone Block,Bone Paste , Polypropylene 3-0 , Polypropylene 4-0 , Pulse Lavage Set , Radiofrequency Probe Compatible Withmitech System (Disposable) , Radiofrequency Probe Compatible With Striker (Disposable) , Radiofrequency Probe Compatible With Karl Stroz (Disposable) , Shaver Blade Of Various Diametres Compatible With Striker System (Disposable) , Shaver Blade Of Various Diametres Compatible With Stroz System (Disposable) , Shaver Burr Various Diametres Compatible With Mitech System (Disposable) , Shaver Burr Various Diametres Compatible With Storez (Disposable) , Shaver Burr Various Diametres Compatible With Striker (Disposable) , Shoulder Drape , Absorable Gelatin Sponge , Stockinette1.5 Meters 3 , Stockinette1.5 Meters 4 , Stockinette1.5 Meters 6 , Suture Lasso L/R Suture Passer , Tourniquet 3 , Tourniquet 4 , Tourniquet 6 , Vacuum Sterile Dressing With Pumo,Collectionbag ,Wound Cover (Vacd System) , 10% Betadinepovidine Iodine Solution , 5% Betadinepovidine Iodine Solution , Betadine Scrub 7.5% (Povidine Iodine) , Disposable Skin Marker Pen , Cling Wrape , Crutchfield Tong , Shoulderimmobilizer , Crepe Bandage 3 , Crepe Bandage 4 , Crepe Bandage 6 , Radial Nerve Palsy (Wrist Drop) Splint , Tailor Brace , Pelvic Binder , Neuro Surgical Patties , Gel Foam , Surgicel , Bk Sponge Traction Adult & Kid , Thomas Splint , Plaster Cutting Blade Compatible With Manman Plaster Cutter , Stapler Remover , Ankle Binder , Arthroscpic Cable Cover , Normal Saline 3 Liter , Vacuum Suction Drain No.12 , Vacuum Suction Drain No.14 , Vacuum Suction Drain No.16 , Mini Vacuum Suction Drain (Arthroscopic) , Surgical Mask With Face Shield , Soft Cotton Roll 4 , Soft Cotton Roll 6 , Knotless Synthetic Quill Barbed Suture With Triangular End Stopper , Shoes Cover , Surgical Cap , Face Shield , Abdominal Drain Kit No.20 , Abdominal Drain Kit No.24 , Abdominal Drain Kit No.28 , Ambu Bag Adult Size , Ambu Bag Paediatric Size , Asepto Syringe , Ayres T- Piece , Bain Circuit With Mask , Camera Cover , Cat Gat 2-0 R.B. , Cautery Tip Pencil , Chest Drain 24F , Corrugated Sheath Drain , Dj Stent 4.5F Both End Open , Dj Stent 4F Both End Open , Dj Stent 5.5F Both End Open , Dj Stent 5F Both End Open , Dj Stent 6F Both End Open , Durapore Plasterall Size , Elastic Adhesive Bandage 10” 2Mtr. , Elastic Adhesive Bandage 6” 2Mtr. , Epidural Catheter Set , Feeding Tube 5F , Feeding Tube 6 F , Feeding Tube No.08 , Feeding Tube No.10 , Foleys Catheter 2 Way 10Fr , Foleys Catheter 2 Way 12Fr , Foleys Catheter 2 Way 14Fr , Foleys Catheter 2 Way 16Fr , Foleys Catheter 2 Way 18Fr , Foleys Catheter 2 Way 6Fr , Foleys Catheter 2 Way 8Fr , Foleys Catheter 3 Way 20Fr , Foleys Catheter 3 Way 22Fr , Foleys Catheter 3 Way 24Fr , Formallin Chamber Large Size (36) , Formallin Chamber Small Size (24) , Inj. Glycine3ltr. , Inj. N.S. 3 Ltr. , Kidney Tray , Knife Blade No.10 , Knife Blade No.11 , Knife Blade No.15 , Knife Blade No.20 , Knife Blade No.22 , Knife Blade No.24 , Laryngeal Mask Airwayno. 1 , Laryngeal Mask Airwayno. 1.5 , Laryngeal Mask Airwayno. 2 , Laryngeal Mask Airwayno. 2.5 , Laryngeal Mask Airwayno. 3 , Laryngeal Mask Airwayno. 4 , Laryngoscope With 4 Blades Adult , Laryngoscope With 4 Blades Pediatric , Long Spinal Needle 23G 12 , Mallecot Catheter 14F , Mallecot Catheter 16F , Mallecot Catheter 18F , Mallecot Catheter 20F , Mallecot Catheter 24F , Nebuliser Mask Adult &Paediatric , Nelaton Catheter 22F , Nelaton Catheter 24F , Oint.Neosporin , Opa , Path Finder , Pcn Dilator Set 10F , Pcn Dilator Set 8F , Pcnl Alligator Forceps , Pcnl Drape , Pcnl Metelicdialator Set , Polydiaxanone 7-0Rb , Polypropylene 1-0Cb , Polypropylene 1-0Rb , Polypropylene 2-0 Cb , Polypropylene 2-0 Rb , Polypropylene 3-0Rb , Polypropylene 3-0Rb , Polypropylene 6-0Rb , R90/K-90 , R91/K-91 , Silastic Dj Stent (Long Term) 5F , Silk 1-0Rb , Silk 2-0Rb , Skin Marking Pen , Spinal Needle 16G 9 , Spinal Needle 18G 9 , Spinal Needle 23G 9 , Stylet Small & Large , Supracath 16F , Supracath 18F , Transpore Plaster 3 , Turp Drape , Tur Set , Under Water Seal Drain , Ureteric Catheter 5F , Ureteric Catheter 6F , Urs Alligator Forceps , Vaccum Suction Tip , Venti Mask (Adult) , Venti Mask (Paediatric) , Ventilating Bougies , Polyglactin 2-0Rb , Polyglactin 4-0 C.B , Polyglactin 4-0 R.B , Polyglactin 6-0 , Polyglactin No-1Rb , Guidewire .035 Inch , Poliglecaprone 25,3-0, 3/8 Circle Cutting 70 Cm , 2-0,1/2 Circle Taper Point 45 Cm Barbed Suture , Polyglactin 3-0Rb , Polyglactin 3-0 C.B , Polyglactin 2-0 C.B , Polyglactin 5-0 , Polyglactin 5-0 , Polyglactin 6-0 , Chromic Gut 3-0Rb , Sugical Wound Dressing Water Proof , Surgical Wound Dressing Water Proofanti Microbial Non Adherent 6*7Cm , Surgical Wound Dressing Water Proofanti Microbial Non Adherent 10*15Cm , Surgical Wound Dressing Water Proofanti Microbial Non Adherent 10*20Cm , Surgical Wound Dressing Water Proofanti Microbial Non Adherent 10*25Cm , Surgical Wound Dressing Water Proofanti Microbial Non Adherent 10*30Cm , Polymer Clip Xtra Large , Polymer Clip Large , Ligating Clip 400 , Bacillocid Solution , D-125 Solution , Op-125 Solution , 4 Layer Sponge , Colostomybag , Oncobcg 40Mg , Oncobcg80 Mg , Ont.Magnisium Sulphate , Lead Apron , Lead Apronstand , Tactra 9.5 Mm Malleable Penile Prosthesis , Tactra 11 Mm Malleable Penile Prosthesis , Tactra 13 Mm Malleable Penile Prosthesis , Circumcision Stapler 26Mm , Circumcision Stapler 30Mm , Circumcision Stapler 32Mm , Instrument Sterliant Sodium Per Carbonate 43 Gm. Teraacetyleehtylenediamine 22Gm. Oxygen Based Bleeching Agents>30% Non Ionicsuractants<5% Phosphates <5% Edta And Salts There Of, Enzymes Perfumes <5% Test Report From Nabl Certified Lab To Be Submitted. The Product Should Be Ce/Is Certified. The Company Should Be En 1499:2013 Certified For Chemical Disinfectant And Antiseptics & Iso 9001:2015 By A Notified Body In Regulated Countries 1. Certificate Of Registrations Issued By United Registrar Of Systems. 2. Document Recognized By Member Of Multilateral Recognition Arrangement. 3. Certified By Ukas Management Systems. , Surgical Scrub Composition: Chlorohexidinegluconate 20% V/W With Organic Surfactants And Free From Sls With Moisture And Skin Softener Test Report From Nabl Certified Lab To Be Submitted. The Product Should Be Ce/Is Certified The Company Should Be En 1499-2013 Certified Of Chemical Disinfectant And Antiseptics & Iso 9001:2015 By A Notified Body In Regulated Countries 1. Certificate Of Registrations Issued By United Registrar Of Systems, 2. Document Recognized By Member Of Multilateral Recognition Arrangement. 3. Certified By Ukas Management Systems. , Nanogel Disinfectant Nanosol Gel Polymer 60% C14,30% C16, 5% C12, 5% C18,…….10% 68% C12, 32%C14….10% Inert Ingredient….80% Usepa Registration Number Mandatory. Usepa Certificate Claim On N-Corona Virus To Be Submitted. Test Report From Internationally Acclaimed Certified Lab To Be Submitted. The Product Should Be Ce/Iso Certified. The Company Should Be En 1499:2013 Certified For Chemical Disinfectant And Antiseptics & Iso 9001:2015 By A Notified Body In Regulated Countries. Certified Should Be Authorized By A Member Of Multilateral Recognition Arrangement. American/European Certificate .-*Iso 13485:2016* *Iso 9001:2015* 1. Certificate Of Registrations Issued By United Registrar Of Systems, 2. Document Recognized By Member Of Multilateral Recognition Arrangement 3. Certified By Ukas Management Systems. , Concentrate Of Proteolytic Enzyme Bromelain 5 G Powder & 50 G Gel For Gel Novel Enzymatic Debridement Solution , Histoglob Inj. Each 1 Ml Contain (Human Normal Immunoglobulin 12Mg Histamindihydrochloride0.15Mcg Sodium Thiosulphate 32 Mg) , Recombinant Anti Rho-D Immunoglobulin/ Trinbelimab 300Mcg , Tpn/Sn Peripheral 1000 Ml Triple Chambered Nutrition (Tpn) 1000 Ml-1300 Ml For Periperal Line Iv Emlusions With 80% Olive / 20% Soya Lipid, Amino Acids, Glucose &Electrolytes.Triple Chamber Bag 1000 Ml-1300 Ml Periperal Line Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L . , Tpn/Sn Peripheral 2000 Ml Triple Chambered Nutrition (Tpn) 1800 Ml-2100 Ml For Periperalline Iv Emlusions With 80% Olive / 20% Soya Lipid, Amino Acids, Glucose &Electrolytes.Triple Chamber Bag 1800 Ml-2100 Ml Periperal Line Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L . , Tpn/Sn Central 1000 Ml Triple Chambered Nutrition (Tpn) 1000 Ml-1300 Ml For Central Line Iv Emlusions With 80% Olive / 20% Soya Lipid, Amino Acids, Glucose &Electrolytes.Triple Chamber Bag 1800 Ml-2100 Ml Central Line Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L . , Tpn/Sn Central 2000 Mltpn/Sn Central 2000 Ml Triple Chambered Nutrition (Tpn) 1800 Ml-2100 Ml For Central Line Iv Emlusions With 80% Olive / 20% Soya Lipid, Amino Acids, Glucose &Electrolytes.Triple Chamber Bag 1800 Ml-2100 Ml Central Line Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L . , Balance Salt Soltions Plasmalyte A 500Ml Calcium Free (Bss) Balanced Salt Solutions For Infusion 500Ml In Non-Pvc Bag, Flexible Bags; Osmolarity – 295 Mosm/L; Sodium Chloride - 5.26/L; Sodium Gluconate - 5.02/L; Sodium Acetate - 3.68G/L; Potassium Chloride - 0.37G/L; Magnesium Chloride - 0.30G/L , Plasmalyte A 1000Ml Calcium Free (Bss) Balanced Salt Solutions For Infusion 1000Ml In Non-Pvc Bag, Flexible Bags; Osmolarity – 295 Mosm/L; Sodium Chloride - 5.26/L; Sodium Gluconate - 5.02/L; Sodium Acetate - 3.68G/L; Potassium Chloride - 0.37G/L; Magnesium Chloride - 0.30G/L , Surgery Fibrin Glu 2 Mlfibrin Sealant With Synthetic Aprotinin- 2Ml. , Fibrin Glu 4 Mlfibrin Sealant With Synthetic Aprotinin - 4Ml. , Fibrin Glu10mlfibrin Sealant With Synthetic Aprotinin - 10Ml. , Floseal 5 Ml Bovine Gelatin Hemostatic Matrix With Thrombin - 5 Ml. , Floseal 10 Ml Bovine Gelatin Hemostatic Matrix With Thrombin - 10 Ml. , Hemopatch 1*1Bovine Collagen Patch Coated With Synthetic Nhs-Peg Size 27Mm*27Mm , Hemopatch 2*2Bovine Collagen Patch Coated With Synthetic Nhs-Peg Size-45Mm*45Mm , Hemopatch 2*4Bovine Collagen Patch Coated With Synthetic Nhs-Peg Size 45Mm*90Mm , Simaglutide Tab. 3Mg , Simaglutide Tab. 7Mg , Simaglutide Tab. 14Mg , Levonorgestren 20 Mcg/ 24 Hour Intrauterine Delivery System , Poly-2-Hydroxyeth , Sweat Band Head Wearable Should Be Manufactured From Non-Woven Fabric, Round Upon Wearing, With Elastic. Should Have Inbuilt Sweat Band Made Of Mixed Of 70 % Viscose [ Bio -Based ] And Polyester [ For Absorption Of Sweat During Procedures ] Should Be Air Permeable/ Breathable, Should Retain Skin And Hair Particals. Should Be Eu Ce & Cdsco Approved. , Pulse Lavage Built In Battery With On/Off Button, Both Short Fan Spray Tip ( Cone Tip ) With Splash Shield& Long Coaxial Canal Tip Connectors Should Be Inside Pack ( Pvc Medical Grade) , Both Irrigation And Suction Tubes ( 3 Mtr ) Should Have Clamps To Prevent The Leakage Of Fluid , Speed Adustable High ( 110 - 1400 Ml/Min Cone Tip & 1000 - 1300 Ml/Mm Coaxial Tip ) To Low Flow Rate 700 Ml/Mm, Pressure Should Be < 15 Psi, Pulse Rate 1500-1700 Cycle/Min, Eu Ce Certify With 4 Digit Notified Body & Cdsco Approved. , Endo Retrieval Pouch , Barrier Two Part Single Use, Active Self- Warming Blanket It Should Be Active Self–Warming And Work Without Additional Equipment/ Electric Supply For Setting Up And During Useit Should Be Single Use Its First Packaging Layer Should Be A Tear Open Plastic Bag. It Should Be Polypropylene Sms Material With 104 Gsm It Should Be Ce Certifiedit Should Be 200 Cm Long It Should Come In Two Part , Joined Together With Valcro.It Should Be Used Before, During, And After Surgery To Help Prevent Peri-Hypothermia In Patients.It Should Have 12 Warming Pads That Are Made Up Of Air-Permeable Bags. , Barrier Single Use, Active Self- Warming Blanket It Should Be Active Self–Warming And Work Without Additional Equipment/ Electric Supply For Setting Up And During Use.It Should Be Single Useits First Packaging Layer Should Be A Tear Open Plastic Bag.It Should Be Polypropylene Sms Material With 104 Gsmit Should Be Ce Certifiedit Should Be 152 Cm Longit Should Be Used Before, During, And After Surgery To Help Prevent Peri-Hypothermia In Patients.It Should Have 12 Warming Pads That Are Made Up Of Air-Permeable Bags. , Ot Table Kit Single Use Quick Suite Set Up Containing 1Unit Sahara Absorbent Sheet (100Cm X 230Cm) With Core Polymer Technology To Wick Off Moisture With 3 Layers Of: Top Quilted Layer, Middle High Absorbent Layer & Non-Slip Back Sheet Bottom Impervious Poly Film Layer To Quick Suite Of Patient; 1Unit Draw Lift Shift (100Cm X 150Cm) Capable To Lift Upto 200Kg For Patient Transfer, Positioning, 1Pair Armboard Cover With Straps With Pe Layer(70Cm X 30Cm), 1Unit Head Positioner Cover With Pe Layer(35Cm X 40Cm). Acceptable Manufacturer Certified With Highest Latest: En 13795-1 Compliant; Us Fda Registered; Iso 13485 Certified; Aus/ En-Eu/ Iec Quality & Safety Standards , Wound Manager Bag (Diameter-104*159 Mm) Small Small,Diameter-104*159 Mm Self Adhesive ,With Flexible Lid, Which Contain A Drain Port To Remove The Effluent From The Bag, Anti-Reflux Valve And Inflatable Ring Which Can Be Filled With Air So That The Lid Should Not Touch The Wound, Unique Daisy Flower Shaped Base Plate For Better Fit To Body Contours. One Transparent Window For Easy Inspection Which Can Be Removed Time And Again For Inspection. The System Should Contain One Transparent Marking Sheet So As To Mark The Required Shape And Size For Cutting Area. , Wound Manager Bag (Diameter-208*297 Mm) Large Diameter-208*297 Mm Self Adhesive ,With Flexible Lid, Which Contain A Drain Port To Remove The Effluent From The Bag, Anti-Reflux Valve And Inflatable Ring Which Can Be Filled With Air So That The Lid Should Not Touch The Wound, Unique Daisy Flower Shaped Base Plate For Better Fit To Body Contours. One Transparent Window For Easy Inspection Which Can Be Removed Time And Again For Inspection. The System Should Contain One Transparent Marking Sheet So As To Mark The Required Shape And Size For Cutting Area. , 60 Mm Colostomy Kit 5 Pcs. Two Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology, With 4 Ears Belt Lock. 5 Pcs. Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage.Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 1 Pc. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. 1 Pc. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatichydrocarbon , Water Base , Gaur Gum 60 Gm. 1 Pc. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. 10 Pcs. Elastic Tape In Semi-Circular Shape With Hydrocolloid Adhesive For Extra Security Of Base Plate.1 Pc. Barrier Spray To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Etrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml.5 Pcs. Cleanser Wipes To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil , Cannula With Universal Standard Connector Cannula With Universal Standard Connector, Lightweight, Flexible Nasal Sof-Tech Special Soft Cannula With Anatomical Design Must Be With Channeled Star Inner Lumen, Crush & Kink Resistant Tubing. Us Fda Registered & If Applicable 510K. Must Be Us Fda/ Bis/ Aus/ Eu Ce Certified With Icmed 13485 Or Iso13485 Certification. , Airlaid Core Super Absorbent Polymer Airlaid Core Super Absorbent Polymer, Disposable Non-Sterile , Passes Is 17786-2022 With Absorption Capacity Of At Least 1000Ml, Absorption Time Of Less Than 2 Minutes And Retention Capacity More Than 10 Times Its Initial Weight.” Usfda/Ce/Bis Compliant, Iso13485 Compliant , Powder-Free Natural Rubber Latex Aloe Vera Gel Coating Powder-Free Natural Rubber Latex Aloe Vera Gel Coating (To Moisturize Dry Skin) With Synthetic Polymer Coating =2.0 Milligrams/Glove As Per Astm D6124 And Iso 21171 With Synthetic Polymer Coating, 100% Pure Freeze-Dried, Brown Colored Lightly Textured, Low-Protein <50 Micrograms/Gram Anatomical, Curved, Reinforced Material Tapered & Beaded Cuff Design; Tested And Passed As Per Astm F 1671; Gamma Radiation, Sterility Assurance Level 10-6; Must Exceed En455-2 En455-3, Astm D3577; Astm D5712 Parameters For Gloves Like Force With 0.65 Aql Final Inspection For Pinholes Test. Acceptable Manufacturer Certified With Highest Latest: En 13795-1; Usfda/Ce/Bis Compliant, Iso13485 Compliant , Sterile Surgical Gown Certified Aami Level 3 Sterile Surgical Gown Certified Aami Level 3 By Govt. Recog Lab/ Body Must Be Bonded/ Glued In Critical Areas, Must Be Made Of 75 Or More Gsm Alcohol Impervious Repellent Poly-Reinforced Fabric, Must Be Of Polypropylene Non Woven& Polyethylene Film With Breathability Of Mvtr: 1500G/M²/24Hours Or More, As Per Iso 15106-1. Acceptable Manufacturer Must Be Certified With Highest Latest: En 13795-1/ Usfda/Ce/Bis Compliant, Iso13485 Compliant Size: S/ M , Sterile Surgical Gown Certified Aami Level 3 Sterile Surgical Gown Certified Aami Level 3 By Govt. Recog Lab/ Body Must Be Bonded/ Glued In Critical Areas, Must Be Made Of 75 Or More Gsm Alcohol Impervious Repellent Poly-Reinforced Fabric, Must Be Of Polypropylene Non Woven& Polyethylene Film With Breathability Of Mvtr: 1500G/M²/24Hours Or More, As Per Iso 15106-1. Acceptable Manufacturer Must Be Certified With Highest Latest: En 13795-1/ Usfda/Ce/Bis Compliant, Iso13485 Compliantsize: L , Sterile Surgical Gown Certified Aami Level 3 Sterile Surgical Gown Certified Aami Level 3 By Govt. Recog Lab/ Body Must Be Bonded/ Glued In Critical Areas, Must Be Made Of 75 Or More Gsm Alcohol Impervious Repellent Poly-Reinforced Fabric, Must Be Of Polypropylene Non Woven& Polyethylene Film With Breathability Of Mvtr: 1500G/M²/24Hours Or More, As Per Iso 15106-1. Acceptable Manufacturer Must Be Certified With Highest Latest: En 13795-1/ Usfda/Ce/Bis Compliant, Iso13485 Compliant Size: Xl , Core Polymer Sheet Core Polymer Sheet---Core Polymer, Breathable Clean Uo Kit Consisting Of Sheet With Anti Slippery Outer Layer102*230 Cm Complies With Iso 9073-6, Absorption Capacity Of 2055%, Lift Sheet 102X152cm With A Capacity Of 224Kg,Armboard Cover With Straps Made Of Impervious And Bilaminate, Usfda/Ce/Bis Compliant, Iso13485 Compliant , Disposable Emesis Bag With Graduated Marking Disposable Emesisbag With Graduated Marking, Should Have Dispenser Which Can Be Keep Bag Closed , Usfda/Ce/Bis Compliant, Iso13485 Compliant , Acetyl Homo-Polymer Ligation Clip Medium Large (Ml) Acetyl Homo-Polymer Ligation Clip Medium Large (Ml) For Vessel . Class Iii Certified, Non- Absorbable, Inert, Non-Conducive, Radiolucent Material. Does Not Interfere With 3 Tesla Mri, Ct & X-Ray Diagnosis. Cartridges Should Have Self-Adhesive Backing. Compatible With 70-Degree Right Angled And 20-Degree Curved Open Applier And Endoscopic Appliers; Size 3-10Mm. Us-Fda Or Ce Certified , Medium Sized Titanium Metal Ligation Clip Medium Sized Titanium Metal Ligation Clip With Usfda And Ce Certification. Should Be Mri Compatible And Conditional With Necessary Certifications , Medium-Large Sized Titanium Metal Ligation Clip Medium-Large Sized Titanium Metal Ligation Clip With Usfda And Ce Certification..Should Be Mri Compatible And Conditional With Necessary Certifications , Minimally Invasive Integrated Access Plus Intrumentation System Minimally Invasive Integrated Access Plus Intrumentation System With Alligator Thumbgrip Graspers (2.3Mm) That Are Manual Instruments For Direct Introduction To Surgical Site Without Need For Trocar, Fabricated Stainless Steel Alloy Shaft Used Percutaneously , Minilappercutaneus Surgical System Minimally Invasive Integrated Access Plus Intrumentation System With Clutch Thumbgrip Graspers (2.3Mm) Are Manual Instruments For Direct Introduction To Surgical Site Without Need For Trocar, Fabricated Stainless Steel Alloy Used Percutaneously , Minilap System With Mini Grip Handle Minimally Invasive Integrated Access Plus Intrumentation System With Alligator Graspers (2.4Mm) Are Manual Instruments For Direct Introduction To Surgical Site Without Need For Trocar, Fabricated Stainless Steel Alloy With Ratchet And Handle Used Percutaneously , Minilap System With Mini Grip Handle Minimally Invasive Integrated Access Plus Intrumentation System With Clutch Graspers (2.4Mm) Are Manual Instruments For Direct Introduction To Surgical Site Without Need For Trocar, Fabricated Stainless Steel Alloy With Ratchet And Handle Used Percutaneously , Pleur Evac Integrated Dry Suction Underwater Seal Chest Drainage System Having Wider Range Of Suction Levels From -10Cm H2o To -40Cm H2o And Has Capacity Of 2500 Mlshould Have Needleless Sampling Port On The Drainage Tube So As To Prevent Infection To The Patient Should Have 4 Column Collection Chamber To Ensure Accurate Patient Readingair Leak Meter Should Be Visual With Negative Pressure Float Valve To Measure Intraplueral Pressure , Optical Trocar 12 Mm Optically Guided Bladeless Trocar 12Mm With Optiview Technology, Having Wiping, Wicking And Absorbing Technology To Reduce Smudging During Camera Reinsertion. With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer , 100Mm Length , Non-Optical Trocar 5Mm/10Mm/12Mm Non-Optical Bladeless Trocar 5 Mm/10Mm/12Mm With Bilateral Tissue Separators, Integrated Universal Seal That Eliminates The Use Of Reducer, Clear Ribbed Cannula To Enhance Abdominal Wall Retention.,100 Mm In Length , Polyglactin 1 No Length 180 Cm Da With One Side Black Tapercut&Other Side Round Body 40 Mm Needle , Polyglactin910 (90% Glycolide& 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Taper Point, 90 Cm. , Pre Knotted Loop Of Polyglactin Attach To A Plastic Tube.Size 1 No 50 Cm , Polyglactin910 (90% Glycolide& 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,30Mm Needle, Size 2-0, 1/2 Circle Taper Point, 90 Cm . , Polyglactin910 (90% Glycolide& 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Reverse Cutting Os Needle, 90 Cm . , Polydiaxanone Port Closer Suture 1No ,70 Cm ½ Circle Rc23 Mm Needle , Polyglactin910 (90% Glycolide& 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,20Mm Needle, Size 3-0, 1/2 Circle Taper Point, 70 Cm , Umbilical Hernia Mesh – Light Weightpolypropylene Patch With Poly Transparents Film Help To Reduce Adhesion Formation And Attach With Polyester Loop With Polypropylrnr Fixation Strapswith Circular Size Of 9 Cm , Polyglactin 910 Violet Braided, 1, 35 Cm 1/2 Circle Reverse Cutting (Heavy) 23 Mm -25 Mm Needle , Polyglactin 5-0 Rb Oval ½ Circle 16 Mm45 Cm , Polyglactin 5-0 Cc 3/8 Circle 16 Mm 45 Cm , Polyglactin910 (90% Glycolide& 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure Mp, Purest Form Of Triclosan, 26Mm Needle, Size 2-0, 3/8 Circle Cutting, 90 Cm , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point, 17 Mm Needle, Length 70Cmsize 3-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point Rb-1, 17 Mm Needle, Length 70Cmsize 4-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 1/2 Circle Taper Point Rb-2, Double Needle, 13 Mm Needle, Length 70Cmsize 5-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 3/8 Circle Taper Point, Bb Single Armed Needle 17 Mm Needle, Length 70Cmsize 5-0 , Absorbable Surgical Suture Sterilized Surgical Double Armedneedledsuturemonofilamentpolydiaxanone Violet 6-0 Rb 17 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armedneedledsuturemonofilamentpolydiaxanone Violet 6-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armedneedledsuturemonofilamentpolydiaxanone Violet 5-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Singlearmedneedled Suturemonofilamentpolydiaxanone Violet 5-0 Rb 17 Mm Needle Length 90 Cm , Monofilament Polyglyconate 1 150Cm Gs-25 Loop, Green48mm1/2 Circletaper Point , Monofilament Polyglyconate 2-0, 75Cm Green26-30Mm1/2 Circletaper Point , Monofilament Polyglyconate 3-0, 75Cm Green20-26Mm1/2 Circletaper Point , Monofilament Polyglyconate 4-0, 75Cm Green17-20Mm1/2 Circletaper Point , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 3-0,70 Cm,1/2 Circle R.B.,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 4-0,70 Cm,1/2 Circle R.B.,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 5-0,70 Cm,1/2 Circle R.B.,13 Mm , Monofilament Glycomer1 90Cm Gs-21 ,Volet37mm1/2 Crcletaper Pont , Monofilament Glycomer 2-0 90Cm Gs-21 ,Volet37mm1/2 Crcletaper Pont , Non Absorbable Surgical Suture, Sterilized Suricalneedledblack Braided Silk With Needle 1/2 Circle Round Bodied 30 Mm Needle , Length 70 Cm Size 2-0 , Braided Coated Non Absorbable Suture Usp 1-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 2-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 3-0 75 Cm X 2 , Silk Reel 4-0 , Braided Polyester Caotedwith Silicon 2,26Mm1/2 Circlerc 75Cm , Braided Polyester Caotedwith Silicon 5,55Mm1/2 Circlerc 75Cm , Polypropylene Blue Monofilament, 2-0, 90 Cm 1/2 Circle Round Body Double Needle 26 Mm , Polypropylene Blue Monofilament Usp 3/0,2,90 Cm,1/2 Circle Taper Point (Double Armed),26 Mm , Polypropylene Blue Monofilament, 4-0, 75Cm 1/2 Circle Round Body Double Needle 17 Mm , Polypropylene Blue Monofilament Usp 5/0,1,90 Cm,1/2 Circle Taper Point (Double Armed),18 Mm , Polypropylene Blue Monofilament, 6-0, 75 Cm 3/8 Circle Round Body(380 Microns) Double Needle (Cutting) 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0,3/8 Circle C1 Taper Point Cv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,8 Mm,60 Cm , Extra Thin Composite Mesh- Made Up Of Polyester & Polyurethane With 115 Gsm& 9Kg/Squarecm Bursting Strength.Havingprefitted Polyester Suture White & Green And Having Visual Marking With Size Of 15 *15 Cm , Har 36 36Cm Shaft, Curved, Tapered Tip For Precise Dissection, Seals 5 Mm Vessels, As Well As Lymphatic With16 Mm Active Blade & 360-Degree Activation, Triggers Support Multiplehand Positions Us Fda Approve Compatible With Gen11 Harmonic , Atraumatic Mesh Fixation Device For Open Hernia Contain N-Butyl 2 Cyanoacrylate 1 Ml With Prolypropylene Mesh 7.6 * 15 Cm , Insulin Degludec /Insulin Aspart , Atraumatic Mesh Fixation Glue Device For Lap Hernia Contain N-Butyl 2 Cyanoacrylate 1 Ml And Mesh Fixation Device 5Mm*375 Mm , Non-Absorbable Synthetic Unidrectional Dual Cut Angle Barb With Welded Loop Or Tab End Made Up Withpolybeutester Size 1, 37Mm, 30Cm, 1/2 Circle, Taper Point , Synthetic Nonabsorbable Wound Closure Device With Dual Cut Barb Withveldedloop Or Tabon End Madeupwithpolybeutester Blue Size 2-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Absorbable Synthetic Unidirectional Dual Cut Angle Barbed With Welded Loop Ortab End Made Up Withpolyglyconate 2-026-30 Mm 30 Cm 1/2 Circle Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb Withveldedloop Or Tabon End Madeupwithpolyglyconate Green Size 1-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb Withveldedloop Or Tabon End Madeupwithpolyglyconate Green Size 2-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb Withveldedloop Or Tabon End Madeupwithpolyglyconate Green Size 3-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb Withvelded Loop On End Madeupwithglycomer Blue Size 2-0, 1/2 Circle, 24Mm, 30-45Cm Rc , Polyester Ethylene Terephthalate Nonabsorbablesurgicalbraided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate.)Long-Chain, Linear Polyesters 1 /2 Circle Tapercut 2 X V-5 Double Needle 26 Mm 90 Cm Green Color Size 2-0 , Laproscopic Knotless Pga -Pcl Bidirectional Taper Point Surgical Suture Self Fixation Device Withautolock Mechanism Made Up Of Pga -Pcl Bidirectional Taper Point 17 Mm & 32Cm , Absorbable Antibacterialpolydiaxononemonofilamenttaper Point Surgical Suture Absorbable Antibacterial Suture Made Up Of Polydiaxonone Coated With Triclosan Voilet Monofilament 1/2 Circle Taper Point Ct-1 40 Mm Needle 90 Cm Suture Size 1 , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 1-0,90 Cm,1/2 Circle R.B.,30 Mm , Non-Absorbable Surgical Suture Black Braided Silk1-0 Rc 3/8 Circle 45 Mm 76 Cm , Non-Absorbable Surgical Suture Black Braided Silk 5-0 Rc 3/8 Circle 12 Mm 76 Cm , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 5-0,76 Cm,3/8 Circle R.B,12 Mm , Non-Absorbable Surgical Suture Black Braided Silk 6-0 Rc Mp 3/8 Circle 8 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 2-0, 1/2 Circle Taperpoint, 36 Mm,100 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet6-0 Rb Micro Point ¼ Circle 8 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 4-0 Cc 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 3-0 Cc 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 5-0 Cc 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 5-0 Rb Oval 1/2 Circle 16 Mm 45 Cm , Non Absorbale Surgical Suturesterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 26Mm Length 70Cm3-0 , Non Absorbable Surgical Suturesterilized Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm4-0 , Non Absorbale Surgical Suturesterlised Surgical Needle Suturepolyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm 5-0 , Non Absorbable Polypropylene Surgical Sutures Size:6-0,3/8 Circle 175-6 Taper Point /Rc Bv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0, Compound Curve ( 1/2 & 3/8 Circle) Circle 175-6 Taper Point Blackmatte Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm , Monofilament Synthetic Absorbable Suturepoliglecaprone 25 - Undyed Ep 3-0,70 Cm,1/2 Circle Oval R.B. J.B. Needle,26 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 3-0, 3/8 Circle Reverse Cutting,Ps Prime 24 Mm,75 Cm , Nonabsorbable Polypropylene Light Weight Macroporous Mesh , Three Dimensional Monofilament Mesh , Atraumatic Mesh Fixation Glue Device For Lap Hernia Contain N-Butyl 2 Cyanoacrylate 1 Ml And Mesh Fixation Device 5Mm*375 Mm , Absorbable 5 Mm Hernia Mesh Fixation Device 30 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4.1 Mm Length Along With Flexible Shaft Up To 3 Cm. , Absorbable 5 Mm Hernia Mesh Fixation Device 15 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4.1 Mm Length Along With Flexible Shaft Up To 3 Cm. , Non Absorbable 5 Mm Hernia Mesh Fixation Device With 30 Helical Shaped Titanium Tacks 3.96Mm Width And 0.61 Mm Diameter , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy , Extra Thin Composite Mesh- Made Up Of Polyester & Polyurethane With 115 Gsm& 9Kg/Squarecm Bursting Strength.Havingprefitted Polyester Suture White & Green And Having Visual Marking With Size Of 15 Cm Circular , Surgical Kit Contain Polyglactin 1 No 180 Cm With Double Arm Suture One Side 1/2 Circle Tapercut Black Needle 40Mm And Other Side 1/2 Crb Needle 40Mm With Polygelecaprone 3/0 Rc Needle ,25 Mm,Length Of 70Cm , Surgical Kit Contain Polyglactin 1 No 180 Cm With Double Arm Suture One Side 1/2 Circle Tapercutneedle 40Mm And Other Side 1/2 Crb Needle 40Mm With Polygelecaprone 3/0 Rc Needle ,25 Mm,Length Of 70Cm And Polydiaxanone 1 No 90 Cm , Linear Cutter 55Mm With 6 Rows, Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Linear Cutter 80 Mm With 4 Rows, Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Universal Linear Cutter Cartridge 80Mm Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 75Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 4 Rows , Universal Linear Cutter Cartridge 55Mm For Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 55Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 6 Rows. , Curved Cutter Stapler 40 Mm Linear Cutter Simultaneous Cutting And Stapling , Curved Green Cartridge Having Close Staple Height Of 2.0 Mm, Tactile Feedback On Completion Of Firing Sequence, New Anvil, Knife With Every Catridge , Circular Stapler 33Mm With Controlled Tissue Compression With, Longer Staple Leg , Laparoscopic Cartridge For Stapler 60 Mm Blue, 1.5 Mm Closed Staple Height 4 Rows Compatible With All Range Ofendoscopic Linear Cutter 60Mm , Laparoscopic Cartridge For Stapler 60 Mm Green, 2.0 Mm Closed Staple Heigh 4 Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Pph Stapler 33Mm - Hemorrhoidal Stapler Kit Consists Of 33Mm Hemorrhoidal Circular Stapler (With Fixed Anvil, Adjustable Closed Staple Height From 0.75 Mm – 1.5 Mm, Staple Open Leg Length Of 5.5 Mm), Suture Threader, Circular Anal Dilator, Purse-String Suture Anoscope, Suture For Purse String. , Optically Guided Bladeless Trocar 12Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Optically Guided Bladeless Trocar 12 Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer Length 100Mm. , Facial Closure Device Contain - Optical Bladeless Trocar With Facial Closure Device Comaptible With Clear Cannula Have Two Side Opening Meant For Uniform Port Closure , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Varied Staple Height Reloads/Cartridges For 80 Mm Gia Instruments, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 60 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 60 Mm Open Linear Cutterreloads/Cartridges Purpule And Black , Eea Circular Stapler Purple Colour Medium Thick , Triple Row With Tristaple Technology (Three Row Of Staple Inner To Outer Row 3.0,3.5 And 4.0 Mm With Sloped Cartridges Face In One Stapler) Diameter 31Mm , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 80 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 80 Mm Open Linear Cutterreloads/Cartridges Purpule And Black , Wound Protector With Double Ring Inmedium 5-9 Cm , Polyglactin 910 With The Length Of 180 Cm.Doubleare ,One Side 1/2 Circle Tapercut Black Needle40 Mm And Other Side 1/2 Circle Rb 40 Mm Needle , Waterproof Antibacterial Silver Dressing With The Size Of 9×15 Cm , Laparoscopic Liner Cutter Without Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 45Mm Capable Of Loading All Length Cartridges On Same Gun Only , Laparoscopic Liner Cutterwithout Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 60Mm, Capable Of Loading All Length Cartridges On Same Gun Only , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,9Cm Length,16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Up To And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip- Focus 9 , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,17Cm Length,16Mm Curved Active Bladewith Adaptive Tissue Technologycapable Of Sealing Blood Vessels Upto And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip - Focus 17 , Advance Bipolar Hand Activated Probe With 5Mm Shaft Diameter And 35 Cm Shaft Length With 5 Mm Wide Straight Jaw Design With Seal Length Of 20Mm And Cut Length Of 16Mm,Sealing Vessel Upto And Including 7Mm Through Radio Frequency Energy And Having A Temperature Controlled Mechanism Within The Jaw And Having Articulation Of 110 Degree(55 Degrees On Both Sides) And Capable Of 360 Degrees Rotation , Advanced Bipolar Tissue Sealer 37 Cms, With 5Mm Shaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm Jaw Aperture Designed For Use In Laproscopic Surgical Procedures With Curved And Tapered Tip And Uses An Advanced Algorithm For Intelligent And Efficient Energy Delivery. Device To Have Intuitive Design With Separate Seal And Cut Button And 360 Degree Continuous Shaft Rotation , Laparoscopic Shears 5Mm Diameter,36Cm Long, 18Mm Curved Coated Blade And A Clamp Arm With Tissue Pad, Capable Of Cutting,Sealing,Grasping And Coagulating Blood Vessels Up To And Including 7Mm In Diameter, 360 Degrees Rotation, Advance Hemostasis Hand Activation Mode For Sealing Vessels Upto 7Mm In Diameter, Ergonomic Handle Compatible With Ultrasonic Energy Source, Capable Of Hand And Foot Activation With An Integrated Hand Piece And Transducer. , Transforming Powder Dressing 4 Inch * 4 Inch/10 Cm*10Cm , Waterproof Antibacterial Silver Dressing With The Size Of 10×15 Cm , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 2.0,2.5 And 3.0 Mm Staple Heights Rowfor Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm For Vascular Applications , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 3.0,3.5 And 4.0 Mm Staple Heights Rowfor Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm Medium To Thick Tissue , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Black Varied Staple Height Of 4, 4.5 And 5Mm Leg Length , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm Or Size 2-3*5-6Cm , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 5*10Cm Or Size 5-7*7-11Cm Or 4*8Cm , Disposable 10 Mm Endoscopic Clip Applier With Facility Of Loading Clips Independent Of The Firing Mechanism: Medium/Large Size , Disposable Clip Applier Preloaded With 20 Clips, Superinterlock Security With Clip Designtechnology Medium , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Urine Collecting Bag, Disposable 2000 Ml With Uroflow Meter , Central Neck Line – Double Lumen (Antimicrobial Coated/ Chlorhexidine , Silver Sulfadiazine Coated)Central Lumen Catheter, Double Lumen) 7 Fr Usfda/Ce Certificate With Notified Body , Microcatheter Selective Infusion Microcatheters For Intra Cranial Aneurysm Treatment With 2 Tip Markers , Microcatheter Selective Infusion Microcatheters For Deploying Intracranial Device: Stent Deployment , Microcatheter Selective Infusion Microcatheters For Flow Diverter Delivery With Single Tip Markers 0.027Inch , Microcatheterflow Dependent Super-Selective High Flow Infusion Microcatheters For Cerebral/Spinal Avms (Compatible With Dmso) , Micro Guide Wirefor Microcatheter Shapable Distal End And With Torque 0.014Inch , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , • Incise Drape Made Up Of Polyester Film With An Acryllc Adhesive That Contains A Complex Of Lodoform (N-Vinyl 2 Pyrrolldine) With A Lodine Concentration Of 0.092 Mg Lodine/Cm2.• Film Should Be Breathable And Conformable To Skin, Compatible With Povidone And Chg Skin Preps.• Lodine From The Drape Should Be Present In The Deepest Skin Layers (1000 Microns Depth) Where Hair Follces Exist Apart From Killing Microbes On Skin Layer.• Produst Should Be Registered As A Class ‘D’ Medical Devise With Cdsco India Since It’S A Antimicroblal Product.• It Should Be Gamma Sterile And Us-Fda Approved. Size Should Be 56Cm “ 45Cm (Adhoslve Area) , A) Ready To Use Hypochlorous Acid Solution Of 0.02 % Concentration For Wound Management. The Ph Of This Solution Should Be Between 4.5 To 6Should Be Non-Toxic, Skin Friendlyshould Be A Cdsco/Sda Approved Productthe Tds Of This Solution Should Not Be More Than 400 Ppm , Surgical Gloves 6.5Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7.5 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Ionic Silver Highly Absurbent Multilayer Foam Dressing With Broad Spectrum Antimicrobial And Having A Soft Siliconadhesive Wound Contact Layer, Providing Sustain Release Of Silver Upto 7 Days Size: 10 Cms X 10 Cms , Self Adherent Moist Wound Foam Dressing Made Up Of Multilayer Matrix With Soft Silicon Adhesive Layer For Pressure Pressure Ulcers/Bed Sores At Sacrum 16 Cms X 20 Cms Approximate , Double Wall Resuscitator With Peep Valve In Adultit Should Be Fully Autoclavable Double Wall With Hand Strapit Should Be Supplied With Autoclavable Reservoir Bagit Should Have A Single Shutter Valve System Made Of Silicone Rubberit Should Have Easy Attachment Of Peep Valve For Adult &Peadiatricit Should Have Provision To Attach Manometer For Paediatrics Ambu Bag Bag Volume: Mark Iv (1300 Ml) Or More Weight: Adult (415 G) It Should Be Us-Fda, Ce & Iso Certified , Double Wall Resuscitator With Peep Valve In Paediatrics It Should Be Fully Autoclavable Double Wall With Hand Strapit Should Be Supplied With Autoclavable Reservoir Bagit Should Have A Single Shutter Valve System Made Of Silicone Rubberit Should Have Easy Attachment Of Peep Valve For Adult &Peadiatricit Should Have Provision To Attach Manometer For Paediatrics Ambu Bagbag Volume: Mark Ivbaby (300 Ml)Weight:Baby (190 G) It Should Be Us-Fda, Ce & Iso Certified , Single Patient Use Sebs Resuscitator (Spur Ii With Peep Valve In Neonatal) • It Should Be Single Use Resuscitator Made To Sebs Material Not Pvc.• It Should Have Unique Single-Shutter Valve System For Reliable Functionality & Swivel Between Valve And Mask Permits 360° Positioning In Relation To The Patient• It Should Have Thin-Walled Compression Bag With Hand Strip.• Resuscitator Volume: Neonate(220Ml)• (Including Reservoir And Mask)• It Should Be Ce/Iso, Us Fda Certified. , Pre-Formed Sga With Gastric Access & Intubationit Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett• It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit.• Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation.• Universal 15Mm Connector (Iso).• It Should Be Ce/Iso, Us Fda Certified , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett• It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit.• Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation.• Universal 15Mm Connector (Iso).• It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga• It Should Be And Autoclavable Up To 40 Times• It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit.• Atraumatic Insertion And Removal.• It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga• It Should Be And Autoclavable Up To 40 Times• It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit.• Atraumatic Insertion And Removal.• It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga• It Should Be And Autoclavable Up To 40 Times• It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit.• Atraumatic Insertion And Removal.• It Should Be Ce/Iso, Us Fda Certified , Offset Connector Cardio Sensor Electrodes• It Should Have High Conductive Wet Gel To Ensure Reliable Traces.• It Should Be Design With Offset Connector To Prevent Artefacts From Disrupting The Readouts• It Should Have High Quality Ag/Agcl Sensor To Ensure Excellent Trace Quality• It Should Have Size Not More Than 72 X 68 Mm• • Sizes –Adult , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy• It Moulded Directly Into The Tube• Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy• It Moulded Directly Into The Tube• Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Ultrasorbs Ap Disposable Drypads, Dry Pad For Moisture Management, 58.4X90cm,With Breathable Layer, Super Absorbent Core, Aqua Shield Film And Air Permeable Back Sheet, Absorbency Of 1800-2300Gm, Usfda/Ce/Bis Compliant, Iso13485 Compliant , Over-The-Ear Nasal Cannulaover-The-Ear Nasal Cannula With Star Lumen, 50 Tubing, Must Be Flexible Contoured Lip Tab Provides A High Level Of Stability And Patient Comfort. Over-The-Ear Design For A Comfortable And Secure Fit, Crush- And Kink-Resistant Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Pediatric Nasal Cannula Softech With Universal Oxygen Connector, 7 Star-Lumen Tubing Lightweight, Flexible Nasal Cannula With Standard Over-The-Ear Designed That Optimizes Fit And Stability, Soft Nasal Prongs Help Maximize Patient Comfort. Individually Packaged For Convenience And Sterility. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Volumetric Incentive Spirometer (Adult)Volumetric Incentive Spirometer (Adult) 4000 Ml And Above With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification , Volumetric Incentive Spirometer (Pediatric) Volumetric Incentive Spirometer (Pediatric) 2500 Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Mask For Tracheostomyadult Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Pardiatric Mask For Tracheostomy Pediatric Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Elongated Aerosol Mask Adult Elongated Aerosol Mask Adult With Under-The-Chin Design For Excellent Fit On Wide Range Of Face Sizes Must Be Clear, Soft Vinyl For Patient Comfort; Adjustable Nose Clip Assures Comfortable Fit; Specifically Designed For Aerosol Therapy; Must Be With Supplied With 6 Ft. Corr A Flex Corrugated Tubing, Featuring Cuttable Sections Every 6 In. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilator Circuit Single Limb Portableadult Ventilator Circuit With Universal Single Limb. Must Be Complete Kit With Main Circuit Hose, Exhalation Valve Manifold, Aerosol Hose, Patient Elbow Connector, Proximal Airway Pressure Line, Exhalation Valve Line, And Humidifier Limb. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilayor Circuit Single Water Trapadult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Infant Prong Cpap Cannula Infant Prong Cpap Cannula Nasal Size 0 With Designed To Reduce Trauma Associated With Delivery Of Infant Nasal Cpap. Must Be Soft Siliconised, Anatomically Curved Prongs To Enhance Fit. Luer Fitting On Expiratory Connector To Allow Proximal Airway Pressure Monitoring. Each Set To Include, Soft Siliconised Cannula; Inspiratory & Expiratory Elbow Connector; Knit Cap; Two 6 In. Hook And Loop Fastener Sections; Two 10 To 7.5 Mm Adaptors. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Fhme Heat And Moisture Exchangers With Bacteria Viral Filtersbacterial Filtration Efficiency≫ 99.99% And Viral Filtration Efficiency ≫ 99.9999% .Filter Membrane Should Be Of A Hydrophobic Non-Woven Polypropylene Material.Should Be Tailored To Meet The Specific Needs Of Both Anaesthesia And Intensive Care. , Tracheostomy Hme:1 Heat And Moisture Exchangers For Spontaneously Breathing Tracheotomy Patients.2 Should Have In Built Oxygen Port.3 Should Be Compact & Light Wt.4 Should Be Suitable For Ambulatory Patients, Sampling And Suctioning Can Be Done Without Removing It.5 The System Should Have Kink Resisting Oxygen Tubing , Double Lumen Endobronchial Tube Left: Size-37Frlow Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage.Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope.X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Double Lumen Endobronchial Tube Left:Size-39Frlow Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope.X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Manifold Manifolds In 2, 3, 5 Port With Configuration Of Left-Right Orientation, On-Off Handle, Full-Half Body, 200 Psi-500 Psi Rating And Wide Port Spacing. Should Have Clear Polycarbonate Body To Provide Durability And Visibility, Airless Rotator And Large Bore Inner Lumen Throughout Including Rotator.Usfda Approved , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material.Sizes Are 5Fr. , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 6Fr , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 7Fr. , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material.Sizes8fr. , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material.Sizesare10fr. , Closed Suction Catheter For Paediatricsnumber And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes 12Fr. , Paediatric Endotracheal Tube Paediatricmicrocuff Designed According To The Paediatricanatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3Mm. , Paediatric Endotracheal Tube Paediatricmicrocuff Designed According To The Paediatricanatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3.5Mm. , Paediatric Endotracheal Tube Paediatricmicrocuff Designed According To The Paediatricanatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 5.5Mm , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. T Size 13Fr . , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering.Sizes16fr. , Catheter Mountdouble Swivel Connector, It Should Have Bronchoscopy Port . It Sholud Be Approved By Us Fda , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaquestripe,Gamma Sterilized Size – 20 Length (0.8 – 5.0) , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism,Radiopaquestripe,Gamma Sterilized Size – 24Fr Length (0.8 – 5.0) , Percutaneous Endoscopic Gastrostomy (Peg)24Fr Percutaneous Endoscopic Gastrostomy (Peg)Medical Grade Silicone Construction.External Retention Ring .Universaland Bolus Feeding Port Connectors,Medicationport.Collapsible Internal Retention Bumper.Radiopaque Stripe And Bumper.Tubingclamp.Etosterilized.Sizes – 24Fr , Neonatal High Flow Nasal Cannula Having8litre Flow. Should Have Soft Tip . , Pur-Xro Catheter 20 Cm, 28G/1Fr Picc Line With Stylet, Splitting Needle With Securing Wings With 8 Cm Extension Tubing (Flow Rate 1Ml/Min) , Pur-Xro Catheter 30 Cm, 24G/2Fr Picc Line With Split Cannula And 10Cm Extension Tubing Over Catheter (Flow Rate 0.2Ml/Min) , Ptfe Coated Diagnostic Guide Wire – (Exchange Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Should Be Available In , 0.035 Inches Size· Should Be 240-300 Cm Long· Should Be Available As Straight Or J-Shaped Tip· Should Be Available Fixed As Well As Movable Core. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Multipurpose Catheterus Fda + Ce/ Dgci Approvedmultipurpose Catheters In Various Standard Curves And Lengths. , Arterial Pressure Monitor Lines (100 Cm Long)Us Fda + Ce/ Dgci Approved·Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (150 Cm Long)Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (200 Cm Long)Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Venaseal Closure System For Varicose Veins Usa/Fda Approved N Butyl Based Adhesive Formation 50/90/105/120 Cm 145 Cm(3/4/6/8 F ,014/0.35 Compatible , Bone Marrow Biopsy Needle With Diamond Bevel Tip & Tapered Distal Canula. Disposable Bone Marrow Biopsy Needle Should Have Ergonomic T- Handle Design With Seprate Handle Cap. Should Have Trocar/Diamond Tip For Easy Coring Of Bone. Should Have Triple Crown Cannula Tip With 6 Facets.Should Be Available With Narrow Acquitioncardle With Sample Size Verfication Marking Should Be Available In 8,11,13 Gauze Usfda/Ce Approved , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Having Maryland Jaw Sealer And Divider With Wide Jaw Aperture 13Mm And Cut Length 18.5Mm With Shaft Rotation Of 350 Degrees And With One Step Sealing Mechanism. Should Have The Manual Cutting Mechanism.And It Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting & Coagulations Device With Tissue Fusion Ligature Technology Have Small Jaw Tissue Sealing System For Open Procedures Vessel Sealing Instrument With Cut Length Of 14.7 Mm, Seal Length Of 16.5Mm, Jaw Angle 28 Degrees. Should Have The Manual Cutting Mechanism.Andits Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligature Technology Laparoscopic Blunt Tipped Vessel Sealer And Divider 37 Cm Long 5Mm Instrument. Wide Jaw Aperture 14.5 Mm With Shaft Rotation Of 180 Degrees ; Multifunctional Laparoscopic Device For Tissue Fusion.Andits Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligasure Technology Instrument For Open Surgeries With Instrument Length Between 21-23 Cm And Electrode Length Between 17-21 Cm Having 22 Degree Curved Zow With Contoure Tip Activation Both Though Hand Activation And Foot Activation With A Manually Controlled Cutting Mechanisn , Cutting & Coagulations Device With Tissue Fusion Ligasuretechnologyhave 36Mm Jaw Length, 180 Degree Rotatable Instrument With Curved Blade For Large Volume Tissue. Should Have The Manual Cutting Mechanism. , Benzyl -C12 -18Alkyl Dimethyl Allonium Chlorides 19.9 G Doudcylbisaropyletramine 5 G Surfactants,Corrosioninhibitors. , Double Lumen Catheter Size- 12 Frx16 Cm Double Lumen Catheter Size- 12 Frx16 Cm (Double Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot)Size- 12 Frx16 Cm With Us Fda /Iso Ce Certified , Double Lumen Catheter Size- 12 Frx13 Cm Double Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slotsize- 12 Frx13 Cm , Long Term Double Lumen Dialysis Catheter Size- 15 Fr X 27 Cm Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided Catheter, Pull Apart Sheath, Dialator, Tunnelling Stylet, Guide Wire J/S, With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade Size- 15 Fr X 27 Cm Usfda Certification Along With Iso, Ce. , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,Withdisppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,Withdisppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Transperant Surgical Wound Dressing Size- 5X 5.72 Cm Tranparent Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidal Protection And Anti Microbial Property. Provide A Waterproof Sterile Barrier To External Contaminating Including Liquids, Bacteria Anf Viruses , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidleproteciton And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Multi-Vent Mask Pediatric, Multi-Vent Mask Pediatric, Air Entrainment Masks, Must Be Safe, Simple Delivery Of Variable Oxygen Concentrations. Each Mask To Includes Color-Coded Diluters: Green For Low Concentration, White For Medium Concentration. Locking Ring To Secure Flow Setting. Must Include Adaptor For High Humidity Entrainment. Complete Kit With 7-Ft Oxygen Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Closed Suction Catheter Mdi Porthas Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port.Catheter Is Made Up Of Medical Grade Silicon Material,Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. , Closed Suction Catheter Mdi Porthas Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Material Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane,Catheter Has Zig-Zag Ports For Better Suctioning. Turbo/ Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Usfda/Eu Ce Notified , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon Material,Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber14 Fr. Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon Material,Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. , Simaglutide Inj..25Mg , Simaglutide Inj..5Mg , Simaglutide Inj.1Mg , Simaglutide Inj.1.7Mg , Simaglutide Inj.2.4Mg , Post Operative Surgical Cover Dressings Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings With Broad Spectrum Bactricidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , Post Operative Surgical Cover Dressingshydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver & Triple Hydrocolloid Matrix Dressings With Broad Spectrum Bactericidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , 2 Pcs Flat Base Ostomy Body Fit60 Mm Kit2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm, Elastic Tape In Semi-Circular Shape With Hydrocolloid Adhesive For Extra Security Of Base Plate. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml.Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatichydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm), Neutral Grey Colourstanderdsizebelt Compatible For Bags Having 4 Ear Hooks , 2 Pcs Convex Base Ostomy Body Fit60 Mm Kittwo-Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm.Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml.Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatichydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm)Neutral Grey Colourstanderdsizebelt Compatible For Bags Having 4 Ear Hooks , 1 Pcs Trasnparent Colostomy Body Fit60mm Kitone-Piece Colostomy Bag- Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.34 N/Mm), Bag Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. One Side Transparent For Inspection 60Mm.Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml.Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatichydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm) , 2 Pcs Flat Base Ostomy Body Fit Bag 60 Mm 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwaterrepellenttextilematerial .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. Window On Bag For Inspection 60Mm .With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic. , 2 Pcs Flat Base Ostomy Body Fit Bag 70 Mm2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Material .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System.One Side Transparent For Inspection. 70Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , 2 Pcs Convex Base Ostomy Body Fit Bag 60 Mmtwo-Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotexcertifiedwater Repellent Textile Material. Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. . Window On Bag For Inspection 60Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , Antimicrobial Transperant Provides Immediate And Continuous Antimicrobial Protection With Integrated Chlorhexidine Gluconate (Chg) Gel Pad, Proven To Reduce Crbsi And Vascular Catheter Colonization, Size 11.5Cm To 8.5Cm, Breathable Film Coating Provides A Barrier To Microbes* And External Contaminants Size 11.5Cm To 8.5Cm, , Sterile Self Adherent With Lipido Colloid Technologysterile Self -Adherentpatented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad , A Superabsorbent Layer ,Avapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. , Sterile Self Adherent With Lipido Colloid Technologysterile Self -Adherentpatented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad , A Superabsorbent Layer ,Avapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. , Polysiloxane And Silicone Gel Sheet For Scar Management Size 10 X10 Cm , Polysiloxane And Silicone Gel Sheet For Scar Management Size 5 X5 Cm , Triple Layer Antimicrobal Form Dressing For Burn Wound With Silver Sulphate, Silver Content 1.2 Mg/Cm 2 With Active Release Of Silver Upto 7 Days With Soft Silicon Atraumatic Wound Contact Layer For Painless Dressing Change. Product Should Be Ce/Usfda Certified Size 20X20 Cm (45Mm) + 15% Deviation Insize Will Be Acceptable. , Triple Hydrocolloid Skin Barrier Where No Cutting Is Required Comprised Of Pectin, Gelatin And Sodium Carboxy Methyl Cellulose,Elastomeric Polymers Extending Turtlenecking Effect And Rebounding Memory Technology With Audible Click And Flexible Tape Collar. , Doudcylbisaropyletraminedidecyl Dimethyl Ammonium Chlorides 13Gsurfactants,Corrosioninhibitors, Foam Regulators ,Ph Regulators, Fragrance , Diddimethylallonium Chlorides -7G Corrosioninhibitors ,Fragrance , Exciplentsq.S, , Nasal Haemostatic Sponge Pack With Out Airway 8Cm , Nasal Haemostatic Sponge Pack With Out Airway 10Cm , Nasal Haemostatic Sponge Pack (With Airway)8Cm , Flexometlic Tube 3-8.5 With Stylet Reinforce Et Tube With Wiring From Tip To Endit Should Be Approved By *Us Fda , Disposable Transducers For Invasive Pressure Monitoring Compatible With Available System In Cath Lab In Smshus Fda + Ce/ Dgci Approved· Disposable Transducers For Invasive Pressure Monitoring· Should Be Compatible With Available System In Cath Lab (Iabp – Data Scope & Cath Lab Transducer) And Iccu At Smsh· Should Meet Highest Medical Industrial Standards· Quality Certification Should Be Provided Form Authorized Agencies , Dialyzer Size 1.3 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Besynthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.4 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Besynthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.6 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Besynthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.8 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Besynthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Padiatric Dialyzer Size 0 .6 Sqmpadiatric Dialyzer (Dialyzer Should Besynthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , Padiatric Dialyzer Size 0.8 Sqmpadiatric Dialyzer (Dialyzer Should Besynthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , B) Ready To Use Hypochlorous Acid Solution Of 0.01 % Concentration For Wound Management. The Ph Of This Solution Should Be Between 4.5 To 6 Should Be Non-Toxic, Skin Friendlyshould Be A Cdsco/Fdaapproved Product The Tds Of This Solution Should Not Be More Than 200 Ppm , Microkleenir (Rust Remover) Composition:- Phosphoric Acid 25% And Cleaner, Instrument Stains Rust Remover With Chelating Agent With Amphoteric Solution Compatible With Manual And Ultrasonic Machine. Test Report From Nabi. Certified Lab Ti Be Submitted. The Product Should Be Ce/Is Certified. The Company Should Be En 1499:2013 Certified For Chemical Disinfectant And Antiseptics &Iso 9001*Iso 13485:2016* Iso 9001:2015* 1. Certificate Of Registrations Issued By United Registrat Of Systems. 2. Document Recognised By Member Of Multilateral Recpgnition Arrangement 3. Certified By Likas Management Systems , Sodium Laurethsulphet, Sodium Chloridd, Peg 7/Glyceryl Cocoate, Cocamidopropyl Betaine, Glycerin, Disodiunlaurethsulfosuccinate ,Peg -120- Methyl Glucose Dioleate. Sodium Benzoate, Sodium Sailcylate. Propylene Glycol Perfume. , Vlc (Suction Disinfectant) Vacuum Line Cleaner, Contains Qac With Non Ionic Surfactant 2.5, Wotj 92.76 Inert Ingredients Should Accumulate Bio File And Kill Biofilm Forming Microorganisms Should Have Recommendation Of Ada Test Report From Nab Certofoed The Company Should Be En 1499:2013 Certified For Chemical Disinfectant And Antiseptics & Iso 9001:2015 By A Notified Body In Regulated Countries Pack Size 1 Ltr. 1. 1.Certificate Of Registrations Issued By 2.Unitedregistrat Of Systems. 3. 2. Document Recognised By Member 4.Of Multilateral Recpgnition 5. Arrangement 3. Certified By Likas Management Systems , Lofilm( Incisefilm ) Sterile Transparent Polyurethane Adhesive Coated Surgical Film With Povidone Iodine Resistant To Do Ph Neutral Water Body Fluid Detergent And Alcohol, Transparent And Breathable Surface And Hold Drape Securely In Place. Test Report From Nabl Certified Lab To Be Submitted The Product Should Be Ce/Is Certified Lab. The Company Should Be En 1499:2013 Iso 13485:2016 Iso 9001:2015 1. 1.Certificate Of Registrations Issued By 2.Unitedregistrat Of Systems. 3. 2. Document Recognised By Member 4.Of Multilateral Recpgnition 5. Arrangement 3. Certified By Likas Management Systems , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride)7.2 X 5 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride) 8X10 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoylchloride)8 X15 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride) 10X20 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride) 10X25 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride) 10X30 , Dressing Specification Specifications: Post Op Transparent Dressing With Pad (Coated With Dialkycarbamoyl Chloride) 10X35 , Pre Padded Synthetic Splint-Specification :Pre Padded Single Inter Locked Knitted Slab If At Least 7 Layers Of Fibreglass, Impregnated With Polyurethane Resin (Synthetic Substrate). Made With Inter Locking Performance (Ilo Technology) For Durable & Light Weight Splintwithdouble Side Padding.10Cm X*4.6Mx*1(Roll) , Pre Padded Synthetic Splint-Specification :Pre Padded Single Inter Locked Knitted Slab If At Least 7 Layers Of Fibreglass, Impregnated With Polyurethane Resin (Synthetic Substrate). Made With Inter Locking Performance (Ilo Technology) For Durable & Light Weight Splintwithdouble Side Padding.12.5Cm X*4.6Mx*1(Roll) , Pre Padded Synthetic Splint-Specification :Pre Padded Single Inter Locked Knitted Slab If At Least 7 Layers Of Fibreglass, Impregnated With Polyurethane Resin (Synthetic Substrate). Made With Inter Locking Performance (Ilo Technology) For Durable & Light Weight Splintwithdouble Side Padding.7.5Cm X4.6Mx1(Roll) , Silk Protein &Nanosilver Based Surgical Mesh Wound Sheet Silk Protein &Nanosilver Based Bilaminated Sterile Surgical Mesh Wound Sheet To Facilitate Drainage Of Exudates, Maintain Optimal Moisture At The Wound Site, Provide Matrix For Cell Attachment ,Migration And Proliferation And Has Anti-Inflammatory Properties. Iso/Ce Approved. Sizes-10Cm X 10Cm , 10Cm X 25Cm , 20Cm X 25Cm , 20Cm X 40Cm , Silk Protein & Antimicrobial Nanosilver Based Sterile Surgical Polyurethene Foam Biomodified, Silk Protein & Silver Impregnated, Soft, Conformable, Absorbent, Triple Layered Polyurethene Foam With Super Fluid Handling Capacity, Slow And Sustained Release Mechanism Of Silver For Prolonged Antimicrobial Activity, Enables Evoporation Of Excess Moisture Out Of Foam, Reduce The Risk Of Maceration, Create Optimal Wound Environment Provide Matrix For Cell Attachement And Proliferation. Iso/Ce Approved.Sizes- 10Cm X 10Cm ,15Cmx15cm,17.5Cm X 17.5Cm,20Cm X 20Cm , Silk Protein &Nanosilver Based Waterproof Post Operative Surgical Sheet Silk Protein And Nanocrystalline Silver Based Sterile, Breathable, Water-Proof Transparent Pu Film Surgical Wound Sheet With Adhesive Border And Center Non-Adherent Absorbent Layer. Iso/Ce Approved. Sizes-9Cm X 21.5Cm , 10Cm X 25Cm, 10Cm X 30Cm. , Silk Protein &Nanosilver Based Waterproof Port Dressing Silk Protein And Nanosilver Impregnated Sterile Water-Proof Transparent Pu Film Surgical Port Dressing With Adhesive Border And Center Non-Adherent Absorbent Layer.Iso/Ce Approved. Sizes-6Cm X 7Cm , 8Cm X 12Cm, 9Cm X 9Cm. , Silk Protein &Nanosilver Based Ag Sprinkling Powder Free- Flowing Hydrolyzed Silk Protein And Nanosilver Based Antimicrobial Ag Sprinkling Powder , Promotes The Growth Of Granulation Tissue And Faster Wound Closure, Absorb Excess Exudates And Maintain Optimal Moisture, Rapid And Sustained Antimicrobial Activity Prevents And Eliminates Infection, Longer Wear Time Fewer Dressing Change, Wide Range Of Application Can Be Used In Surgical, Acute And Chronic Wounds. Iso/Ce Approved. Sizes-50Gm , 100Gm , 250Gm, 500Gm. , Silk Protein &Nanosilver Based Ag Particlecompletely Bio-Absorbable Pure Lyophilized Silk Protein &Nanosilver Based Antimicrobial Particle, Having Excellent Bio-Availibility Better Contact With Celluler Components Arround The Wound Bed, Provide Structural Matrix For Tissue And Vascular Growth, Stimulating The New Granulation Tissue, Fibroblast And Collagen Synthesis, Promotes Healthy Granulation For Early Grafting. Sizes- 2Ml , 5Ml , 10Ml. , Silk Protein &Nanosilver Based Amorphous Hydrogel Silk Protein And Nano Colloidal Silver Based Amorphous Hydrogel To Provide Anti-Microbial Barrier As It Deslough And Debride, Rehydrates Non-Viable Tissue, Assist Autolytic Debridment In Dry Wounds Covered With Necrotic Tissue. Iso/Ce Approved. Sizes- 25Gm, 50Gm , 100Gm , Silk Protein & Papain-Urea Based Wound Debriding Ointmentpapain-Urea & Silk Protein Based Wound Debriding Ointment For Removal Of Necrotic Tissue And Sloughwhich Effectively Liquifies Of Denatured And Non-Viable Tissue Without Harming Healthy Viable Tissue, Ph Range (3-12) Containing Papain Ip :>521700 Units And Urea Ip : 100Mg). Iso/Ce Approved Sizes-25Gm, 50Gm, 100Gm. , Silk Protein & Colloidal Silver Particle Solution Spray Silk Protein &Nono-Sized Colloidal Silver Particles Solution Spray For Cleaning And Irrigating, Having Antimicrobial Wound Healing Properties, Effectively Inhibits The Growth Of Microorganisms, Enhance Healing Of Damaged Skin Tissue By Triggring Skin Re-Growth And Repair. Iso/Ce Approved.Sizes- 250Ml , 500Ml, 1000Ml. , Silk Protein And Silver Based Hydrophilic Absorbent Foam Dressing In T Shape Central Hole. Biomodified Silk Protein And Nano Silver Based Soft, Highly Conformable, Non-Adherent Antimicrobial Polyurethene Foam Dressingcomprised Ofsilk Protein 8% And Silver 1.2% With Super Fluid Handling Capacity (10X Of Its Weight), With An Unique ‘T-Shape’ Design With ‘Circular Aperture Hole With 12.5Mm Diameter At The Center’ Which Further Simplifies Its Application And Enables The Foam Dressing To Perfectly Fit Around A Tracheostomy Tube And Peristomal Area.The Dressing Is Specially Designed To Protect The Skin Surrounding Tracheostoma Against Abrasion, For The Management Of Fluid, Secretion, Or Exudate Build-Up Associated With The Use Of Tracheostomy Tubes. Iso & Ce Approved. Size : 9X9.5Cm , Silk Protein And Chitosan Based Haemostatic Sponge Dressing , Silk Protein And Chitosan Composite Bilayered Non-Absorbablehaemostatic Sponge Dressing Iso/Ce Approved. Sizes- 3.5Cm X 3.5Cm, 5Cm X 5Cm, 8Cm X 8Cm , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure(Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable .Patented Release Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds . , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility , Non Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteriaproof Semi-Permeable .Patented Release Profile Of Ionic Silver Upto 7 Days.Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds And Burn Cases. , Hydrocolloid Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable .Patented Release Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds . , Highly Absorbent Polyurethane Foam Dressing For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure(Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. , Highly Absorbent Polyurethane Foam Dressing With Hydrocolloid Adhesive Border For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure(Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. , Calcium Alginate Dressing With 65-75 % Guluronic Acid , Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption. For Managing Sloughy Wounds With Cavity . , Calcium Alginate Dressing With A Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption And Gel Formation. 5.7%- 6.3% Sodium Zirconium Crystals Contains Silver Which Provide Broad And Continuous Antibacterial Profile For Upto 7 Days And Prevents Microbial Colonisation. For Managing Infected Sloughy Wounds With Cavity And Various Shapes, Sizes And Depths. Comes With Spin Finish To Prevent Fibre Shredding And Has Document Haemostatic Effect , Hydrogel Consisting Of Natural Ingredients Such As Highly Purified Water, Sodium Carboxy-Methylcellulose And Calcium Alginate Without Any Additives. For Effective And Gentle Autolytic Debridement Of Necrotic Tissue , Dry And Sloughy Necrotic Wounds. , Hydrocolloid Dressing Containing Calcium Alginate + Carboxy Methyl Cellulose With High Absorption Efficiency ,Semi Permeable Waterproof And Bacteria Proof Top Film, Unique Dressing Change Indicator , Wound Mapping Grid Pattern , Free From Pectin Or Gelatin.For Managing Medium To Low Exuding Wounds . , Thin Hydrocolloid Dressing With High Permeability Capabilities &Waterproof , Transparent, Wound Mapping Grid Pattern , Free From Pectin Or Gelatin. For Managing Low Exuding Wounds. , Kit Of Single Shot Intrarticular 4.8Ml Combination Set With 3.8Ml Hyaluronic Acid (2.5%) & 1Ml Prp (1.5 Million Plt/Ul) , Hydrophilic Polyurethane Foam Sterile Catheter Dressing With Securing Tape 20Ml Ooze Absorption And Middle Cut. , Hand Gel Ethanol 85G.& Skin Protectors W/W , A Permanent Barrier Separator Mesh With 3D Polymer Matrix On Parietal Side Fused To Silicon Film On The Visceral Side To Prevent Adhesions. Meshshould Have Perforations To Prevent Seroma Formation. Should Have Prefix Pp Sutures Size 10X15 Cm , A Permanent Barrier Separator Mesh With 3D Polymer Matrix On Parietal Side Fused To Silicon Film On The Visceral Side To Prevent Adhesions. Meshshould Have Perforations To Prevent Seroma Formation. Should Have Prefix Pp Sutures Size 15X15 Cm , A Permanent Barrier Separator Mesh With 3D Polymer Matrix On Parietal Side Fused To Silicon Film On The Visceral Side To Prevent Adhesions. Meshshould Have Perforations To Prevent Seroma Formation. Should Have Prefix Pp Sutures Size 20X15 Cm , A Permanent Barrier Separator Mesh With 3D Polymer Matrix On Parietal Side Fused To Silicon Film On The Visceral Side To Prevent Adhesions. Meshshould Have Perforations To Prevent Seroma Formation. Should Have Prefix Pp Sutures Size Circuler 15 Dia , Single-Use Brush Sponge Impregnated With 4% Chlorhexidine Digluconate Soap For Surgical Hand Disinfection With Polyethylene Super Soft Bristles. , Single-Use Sponge Impregnated With 4% Chlorhexidine Digluconate Soap For Skin Cleansing And Disinfection. , Post Operative Elbow Orthotic Made Of Padded Lined Aluminium Cuffs With Extension Limitation Of 0-105 Degree, Flexion Limitation Of 0-120 Degree And Lock Limitation Of 0-90 Degree Adjustable In Every 15 Degree With Hand Grip. Also With Anti- Supination / Pronation Arm Bar Kit.- Right Universal. , Post Operative Elbow Orthotic Made Of Padded Lined Aluminium Cuffs With Extension Limitation Of 0-105 Degree, Flexion Limitation Of 0-120 Degree And Lock Limitation Of 0-90 Degree Adjustable In Every 15 Degree With Hand Grip. Also With Anti- Supination / Pronation Arm Bar Kit.- Left Universal. , Knee Unlade External Device With 18-20 Degree Emendation- Left Universal , Knee Unlade External Device With 18-20 Degree Emendation- Right Universal , Hip External Device With Highly Permeable Fabric Offering Flexure And Extension From 0-100 Degree With Abduction And Adduction -60 To 60 Degree.(Universal) , Tool Less Ligament Orthotic With Extension Stops At 0, 10, 20, 30, 40 Degree: Flextion Stops At 0, 10, 20, 30, 40 Degree: Immobilization Stops At 0, 10, 20, 30 Degree. Made Up Of Light Weightaluminium Frames With Heat Molded Eva Foam Paddings Without Stitching Seam And Have Ant Slip Silicon. Cushioned Pads With Anti Slip Silicon And Labeled Number Straped Guide. Magnetic Top To Make Easy Change In Flexion, Extension And Immobilisation. - Right , Tool Less Ligament Orthotic With Extension Stops At 0, 10, 20, 30, 40 Degree: Flextion Stops At 0, 10, 20, 30, 40 Degree: Immobilization Stops At 0, 10, 20, 30 Degree. Made Up Of Light Weightaluminium Frames With Heat Molded Eva Foam Paddings Without Stitching Seam And Have Ant Slip Silicon. Cushioned Pads With Anti Slip Silicon And Labeled Number Straped Guide. Magnetic Top To Make Easy Change In Flexion, Extension And Immobilisation. - Left , 3Ml Pfs Of Cross Linked Sodium Hyluronate 3% W/V- 90/3Ml. , Organically Embedded Nano Particle Antimicobial And Antiviral Nitrile Mitt Without Activator - Extra Small , Organically Embedded Nano Particle Antimicobial And Antiviral Nitrile Mitt Without Activator - Small , Organically Embedded Nano Particle Antimicobial And Antiviral Nitrile Mitt Without Activator - Medium , Organically Embedded Nano Particle Antimicobial And Antiviral Nitrile Mitt Without Activator - Large , Organically Embedded Nano Particle Antimicobial And Antiviral Nitrile Mitt Without Activator - Extra Large , Set Of 100% Waterproof Layered Casting Liner Of Polytetraflouroethylene (E Ptfe) With Removal Aid Synthetic Cast. , Rapid Testing Kit For Bladder Tumor Antigen Diagnosis Using Monoclonal Antibodies To Detect Presence Of Bladder Tumor Associated Antigen In Urine (Box Of 10 Test) , Gluteraldhyde :15.2G 1,6-Dihydroxy 2,5- Dioxahexane : 19.7Grust Inhibitors & Hi- Tech Cleansors .At 4% Solution Ph-Value Approx .7 , Parially Absorbable Mesh Of Polyprolylene Strandswith Abrosbable Poliglecaprone 25 Material Strands . Size 15X15 Cm , Parially Absorbable Mesh Of Polyprolylene Strandswith Abrosbable Poliglecaprone 25 Material Strands . Size 20X15 Cm , A Permanent Barrier Separator Mesh Withknittedpolypropylenemesh On Parietal Side And Polyethylene Sheet On The Visceral Side To Prevent Adhesions. Mesh Should Have Perforations To Prevent Seroma Formation.Should Have Prefix Pp Sutures Size 10X15 Cm , A Permanent Barrier Separator Mesh Withknittedpolypropylenemesh On Parietal Side And Polyethylene Sheet On The Visceral Side To Prevent Adhesions. Mesh Should Have Perforations To Prevent Seroma Formation.Should Have Prefix Pp Sutures Size 15X15 Cm , A Permanent Barrier Separator Mesh Withknittedpolypropylenemesh On Parietal Side And Polyethylene Sheet On The Visceral Side To Prevent Adhesions. Mesh Should Have Perforations To Prevent Seroma Formation.Should Have Prefix Pp Sutures Size 30X30 Cm , A Permanent Barrier Separator Mesh Withknittedpolypropylenemesh On Parietal Side And Polyethylene Sheet On The Visceral Side To Prevent Adhesions. Mesh Should Have Perforations To Prevent Seroma Formation.Should Have Prefix Pp Sutures Size 12 Cm Dia , A Permanent Barrier Separator Mesh Withknittedpolypropylenemesh On Parietal Side And Polyethylene Sheet On The Visceral Side To Prevent Adhesions. Mesh Should Have Perforations To Prevent Seroma Formation.Should Have Prefix Pp Sutures Size 15 Cm Dia , Macropore Polypropylene Pre Cut Shaped 4.5X10cm , Macropore Polypropylene Pre Cut Shaped 6X13.7Cm , Triclosan Coated Anti Bacterial Monofilament Voilet Polyglecaprone 25 Suture Size 2-0, 70 Cms ,1/2 Circle Round Body 26 Mm. , Triclosan Coated Anti Bacterial Monofilament Voilet Polyglecaprone 25 Suture Size 3-0, 70 Cms ,1/2 Circle Round Body 26 Mm. , Skin Stapler With 45 White Pin , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 90Cm Loop Unidirectional ,No 1 Heavy , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 26Mm 15Cm Loop Unidirectional 3-0 , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 23Cm Loop Unidirectional 2-0 , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point Heavy Double Needle 37Mm 36Cm+36Cm Loop Bidirectional ,No 1 , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 15Cm Loop Unidirectional , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 26Mm 30Cm Loop Unidirectional 2-0 , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 30Cm Loop Unidirectional ,0, Heavy , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 30Cm Loop Unidirectional ,No 1 Heavy , Partially Absorbable Anatomical 3 Dimensional Mesh Made Of Polypropylene And Pgcl . The Mesh Should Be In Dimension Of 12 X 17Cms. The Mesh Should Be Specially Contoured For Fixing To Inguinal Anatomy . The Mesh Should Have Both Right And Left Variants . , Partially Absorbable Anatomical 3 Dimensional Mesh Made Of Polypropylene And Pgcl . The Mesh Should Be In Dimension Of 11 X 15Cms. The Mesh Should Be Specially Contoured For Fixing To Inguinal Anatomy . The Mesh Should Have Both Right And Left Variants . , Eustachian Tube Balloon Dilatation Kit , Airway Balloon Dilatation Kit , Balloon Sinoplasty Kit , Tracheal T Tube (Bio-Compatible Silicone) All Sizes , Nasal Packing8 Cm Box , Nasal Packing10 Cm Box , Adenotonsillectomywand Compatible With Existing Genrator System , Tonsillectomy Wand Compatible With Existing Genrator System , Laryngeal Wand Compatible With Existing Genrator System , Mini Laryngeal Wand Compatible With Existing Genrator System , Turbinate Wand Compatible With Existing Genrator System , Tracheostomy Tube All Sizes , Rf Plasma Generator Equipment For Ent , Videoscope , Airway Nasal Splint Box , Bivalve Nasal Spint , Precut Nasal Splint , Balloon Inflation Device , Tracheostomy Tube All Sizes , Rf Plasma Generator Equipment For Ent , Polydioxanone Antibacterial Coating With Triclosan Knotless Closure With Barb Arranged In 72 Degree Spiral Arrangements With 1/2 Circle Taper Point 37Mm 45Cm Loop Unidirectional ,No 1 Heavy , Monofilament Non Absorbable White Color Dense Poly Tetra Fluoro Ethylene Suture With 3/8 Circle Reverse Cutting 16Mm Black Needle On 4-0 Size Suture , Monofilament Non Absorbable White Color Dense Poly Tetra Fluoro Ethylene Suture With 3/8 Circle Reverse Cutting 16Mm Black Needle On 3-0 Size Suture , Monofilament Non Absorbable White Color Dense Poly Tetra Fluoro Ethylene Suture With 3/8 Circle Reverse Cutting 19Mm Black Needle On 2-0 Size Suture , Partially Absorbable Anatomical 3 Dimensional Mesh Made Of Polypropylene And Pgcl . The Mesh Should Be In Dimension Of 9 X 13 Cms. The Mesh Should Be Specially Contoured For Fixing To Inguinal Anatomy . The Mesh Should Have Both Right And Left Variants . , Flexible Urethral Dialator Set , Giga Granuls1.5 Kg Basleef Of Pearls 100Grm Granules Contain 43.0 G Sodium Percarbonate, 22.0 G Tetraacetylethylene Diamine , Hydroxypropyl Methylcellulose Ophthalmic Solution Usp Syringe -2Ml With Sterile Single Use Cannula , Umbilical Hernia Mesh -Light Weight Polypropylene Patch With Poly Trasparents Film Help To Reduce Adhesion Formation And Attach With Polyester Loop With Polypropylrnr Fixation Straps With Circular Size Of 9Cm , Extra Thin Composite Mesh-Made Up Of Polyester & Polyurethane With 115Gsm & 9Kg/Square Cm Bursting Strength. Having Prefitted Polyester Suture White & Green And Having Visual Marking With Size Of 15 *15Cm , Extra Thin Composite Mesh-Made Up Of Polyester & Polyurethane With 115 Gsm & 9Kg/Square Cm Bursting Strength. Having Prefitted Polyester Suture White & Green And Having Visual Marking With Size Of 15Cm Circular , Extra Thin Composite Mesh-Made Up Of Polyester & Polyurethane With 115 Gsm & 9Kg/Square Cm Bursting Strength. Having Prefitted Polyester Suture White & Green And Having Visual Marking With Size Of 12Cm Circular Pre Knotted Loop Of Polyglactin 910 Attach To A Plastic Tube. Size1 No 50Cm , Pre Knotted Loop Of Polydioxanone910 Attach To A Plastic Tube. Size1 No 50Cm , Atraumatic Mesh Fixation Device For Lap Hernia Contain N-Butyl 2 Cyanoacrylate 1 Ml And Mesh Fixation Device 5Mm*375Mm , Atraumatic Mesh Fixation Device For Lap Hernia Contain N-Butyl 2 Cyanoacrylate 1 Ml And Mesh Fixation Device 7.6Mm*15Cm , Polydiaxanone Port Closer Suture 1No,70Cm½ Circle Rc 23Mm Needle , Disposable Optical Trocar 5Mm , Disposable Optical Trocar 10Mm , Gelatin Hemostatic Matrix With Thrombin-10Ml , Disinfactant With Multienzyme100gm Of The Granules Contains Active Ingredients 43.0Gm Sodium Percarbonate, 22.0Gm Tetraacetylethylenediamine And Enzymes Passes En13624, En 13727,En14348, En14561,En14562,En14563,En13704 And En 14476 Standards With Market Standing Certificate. , Multi-Enzyme High-Performance Detergent With Disinfectanteach 100Gm Contains 7.7Gm Didecyldimethylammonium Chloride, 0.4 Gm Of Polyhexamethylene Biguanide And Enxymes Passes En 13624, En13727, En14561 And En 14562 Standards With Market Standing Certificate , Surgical Scrubchlorhexidine Gluconate Solution Ip 20% V/V (Equivalent To Chlorhexidine Gluconate 4% W/V) With Isopropanol<10% Ethoxylated Alkylphenol<10% Fatty Acid Diethanolamid<10% Acetic Acid Glacial<1%,Cellulose And Fragrance<10%Emollient & Moistursing Agents Passes En1499 Standards, Must Be Free From Paraben And Sulphates , Body Wipes With Octenidineoctenidine Based Wash Mitts With Pratical Hand Dimesnsion, Tested As Oer Wuropean Norms Containing Octenidine Hcl,Aqua,Glycerine,Cocamidopropylamine Oxide, Sodium Lactate, Allantoin, Ethylhexyl Glycerine, Effective Against Mdros With Market Standin Certificate , Pre And Post Surgical Body Washoctenidine Based Wash Lotion With Neutral Ph Tested As Per European Norms Containing Octenidine Hcl,Aqua, Cocamidopropylamine Oxide, Peg-7 Glycer; Cpcpate, Glycerin Hydroxyethyl-Cellulose,Lactic Acid,Contains Allantoin For Full Body Wash- Head To Toe, Must Be Effective Against Mdros With Market Standin Certificate , Surface Disinfectant For Terminal Cleaning10%V/V Stablised Hydrogen Peroxide With Silver Ions Must Have Demonstrated >5Log Reduction In 5 Minuted Certified With Bs En13727-Ecoli, Pseudomobas Aeruginosa, Staph Aureus, Enterococcus Hirac & Acintobacter Baumannii And Bsen13624-Candida Albicans, Aspegillus Brasiliensis & Candida Auris, Solution Should Be Non Toxic Nonirritating And Eco Friendly. , Hygienic Hand Disinfectionchlorhexidine Gluconate Solution Ip2.5%V/V (Equivalent To Chlorhexidine Gluconate 0.5%W/V) And Ethanol Ip 70% V/V Emollient & Moisturing Agents Passes En 1040 And En 12791 Standard Tested In An Iso 17025 Internationally Accredited Lab. , Reentry Surgical Scrub With Alcohol Base Gel79.9% V/V Ethanol Ip Gel With Emollients And Moisturizers Passes En 13727 Standard , Instant Surface Disinfectant70% V/V Isopropyl Alcohol With Surfactant And Corrosion Inhibitors With Hand Sprayer For Rapid Surface Disinfection , Surface Disinfectant Wipes100 Ready To Use [Resaturated Wipes With 17.4Gm Propanol And 12.6Gm Of Ethanol(94%W/W) Passes En13727,En14348,En13624,En14476 , Automated Dispenser For Touhless Handhygienebattery Operated Hand Scrub And Handrub Touchless Dispenser With Three Level Dispensing Switch , Surgical Scrub4% Chg Surgical Scrub Should Be Used Only For Battery Operated Automated Dispenser Passed En1499 Certification , Surgical Scrub7.5% Providone Iodine Surgical Scrub Should Be Used Only For Battery Operated Automated Dispenser , Handrub For Critical Areaschlorhexidine Gluconate Solution Ip 2.5% V/V (Equivalent To Chlorhexidine Gluconate 0.5%W/V) And Ethanol Ip 70% V/V Emollient & Moisturising Agents Passes En1040 And 12791 Standards Tested Ub As Iso-17025 Internationally Accredited Lab , Surface Disintectant100gm Solution Contain Alkyldimethylbenxyl Ammonium Chloride, 17Gm Phenoxyethanol And 0.9G Amines With Chloroacetic Acid , Soda Lime Should Have A Medical Grade Alkali (Koh & Naoh Free) , Coustom Patient Gown And Trouser Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 9
16.
Housing Urban and Rular Development #10834920 Price Bid
Tender For Providing Allied Works Regarding Tourism At Parashar Temple In Paregaon Tal Chandwad Dist Nashik-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 meter) 2 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft imapactor Grade finely washed etc) 3 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. Bd.A. 11/Page No. 263 4 Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. Bd.A. 11/Page No. 262 5 Providing dry/ trap/ granite/ quartzite/ gneiss rübble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete. 6 Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/Vertical Shaft Impactor quality Artificial Sand. 7 Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand. 8 Providing and casting in situ cement concrete M-25 of trap /granite/quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With natural sand. 9 Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand 10 Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting, curing, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand 11 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand 12 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand 13 Providing and fixing in position Thermo Mechanically Treated FE 500 bar reinforcement of various diameters for -Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 14 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. 15 Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 16 Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 17 Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild, steel longitudinal reinforcement of 2 bars of 6 millimetre diameter / 2 hoop iron strips 25 millimetre X 1.6 millimetre placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 18 Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. 19 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. 20 Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 21 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 22 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in/cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. 23 Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. 24 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring 25 Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimeter x 30 centimeter and confirming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. 26 Providing and laying vitrified mirror / glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting 27 Providing and laying ceramic tiles of having size 30 centimeter x 30 centimeter and confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etc. complete. 28 Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. 29 Providing and laying telephone black / Amba White /Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. 30 Providing and applying priming coat on concrete/ masonary/Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. 31 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete. 32 Providing and applying white-wash in one coat on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing & brooming down etc. complete. 33 Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. 34 Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to IS. 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. 35 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete 36 Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35 millimetre thick style and rail with 25 millimetre thick panels with openable fan light as per detailed drawings. Excluding the door frame 60 millimetre X 100 millimetre stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. 37 Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 38 Providing and Fixing 30 millimetre thick FACTORY MADE BOTH SIDE PRELAMINATED SOLID PANEL Poly Vinyl Chloride DOOR SHUTTER consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 millimetre for styles and 15 X 15 millimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Vinyl Chloride C channel made from 5 millimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubicmetre, of size 30 millimetre thickness 70 millimetre width out of which 50 millimetre shall be flat and 20 millimetre shall be tapered in 45 angle on either side forming stiles; and 5 millimetre thick, 95 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered in 45 on the inner side to form top and bottom rail and 115 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride strip of 20 millimetre width is to be stuck on the bottom side of the c channel prelaminated paneling of 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride sheet to be fitted inside the Mild Steel frame welded / sealed to the styles and rails with 5 millimetre (+/-0.25) x 30 mm Poly Vinyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc, 10 millimetre thickness (5 millimetre (+/-0.25) x 2 Numbers) 20 millimetre wide cross Poly Vinyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 Numbers Mild Steel powder coated but hinges of size 100 millimetre x 25 millimetre x 2 millimetre using 32 millimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 millimetre size steel screws including fixture fasting. Complete as per direction of engineer-in-charge. 39 Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 * 38.1 * 0.9 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 * 31.75 * 1.3 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 * 31.75 * 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 * 18 * 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 * 18 * 1.1 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 * 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box 40 Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 * 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete.41 Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. 42 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. 43 Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) 44 Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. 45 Providing and fixing on walls/ ceiling/ floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. 46 Providing and fixing on walls/ ceiling/ floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. 47 Providing and fixing on walls/ ceiling/ floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
Maharashtra View Result →
17.
Housing Urban and Rular Development #10803700 Price Bid
E-Quotation No.5 For 2022-23 E Rate Quotation For Preparation Of Ssr For Various Item Which Is Mention In Notice , For Steel Structure / Tmt -Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) For Concrete Surface -Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kleox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Top Terrace Waterproofing -- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Waterproofing Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Waterproofing Of Concrete Surfaces Of Terrace To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Of Existing Terrace Surface Upto Mother Slab Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60Of Dimple Chemicals & Services Pvt. Ltd After Finishing, After Top Coat Application, Pcc Will Be Done Up To 50 Mmthickness ( Or As Per Site Condition ) Of Desire Slope To Drain The Water And Kept Ponded For Continuous Period Of 3 Days To Detect Any Seepage / Leakage / Dampness If Any, The Surface Then Shall Be Cleared, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd After Finishing It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas, Lift Jointsetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Road Surfaces To A Thickness Upto 15 Mm Or As Per Surface Conditions And Also Treatment Of Pot Holes, Cracksetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 25 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying Poly Ironite Ceramic Cementitious ( Picc ) Ofdimple Chemicals & Services Pvt. Ltd Ensure Self Curing, High Abrasion Resistant, Non-Shrink, High Compressive Strength, Low Porosity, Uv Resistant Coating Mortar On Existing Well Gsb Of 100 Mm Thickness, Get Compacted Andlevelled , Cure The Surfacethen Applyingself Curing Coating Picc Mortarin Properation Of 1;1 ( Nicomix Series : Metal ) For 50 Mm Thickness After Stamp The Surface By Special Concrete Stamping Mould As Per Specified Texture And Colour Etc. Next Day Apply Finish Coat Of Kelmer A60 Of Dimple Chemical & Services Pvt. Ltd Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. ( Note- Gsb , Colour & Stamping Rates Not Included In This Ra ) , Masonry Bridge Repair Work:- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For T-Pointing To A Depthupto 50 Mm Or As Per Surface Conditions And Raised On Stone Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Joints With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Top Coat Will Be Done With Kelmer A 60 + Niccoat Pc On Picc To Seal The Surface And Reduce The Porosity Etc Complete As Per Specification Including Cost Of All Material, Machinery, Labour, Scaffolding, Transportation Etc. With All Leads And Lifts As Directed By The Engineer-In-Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm In A Ratio Of 1:1 ( Picc Mortar1 Part: Metal 6Mm 1Part ) Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 In To Above Morter For Normal Setting Of Dimple Chemicals & Services Pvt. Ltd. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 Of Dimple Chemicals & Services Pvt. Ltd. On Above Mortar Picc Will Be Ready To Traffic Load After 1 Hr Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying 30 Mm Thick Self Curing Ceramic Polymer Microconcrete Of Dimple Chemicals & Services Pvt. Ltd. Having Compressive Strength Above M30, Non Shrink, Impermeable, Filling Mortar In Cavities Like Beams, Column Etc. To Load Carrying R.C.C Member In One Or Two Layers ( Depending Upon The Site Condition ) On Cleaned Concrete Surface , Includinghoney Comb Area ( Using Manual / Mechanical Means ) . Mixingmortar Of Nicocil C80 And Fresh 53 Grade Cement With Required Water Cement Ratio For Desired Consistency And Applying And Finishing By Manual Trowelling , Curing After Curing Initial Setting Time Etc, As Per Manufacturers Specification Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Kelox R 101 ( Resin ) + Kelox H 404 ( Hardener ) A Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. For Bonding Old Concrete To New Picc Mortar, After Mixing Slowly In Predefined Ratio And Applying By Brush On The Surface. When It Is Tacky Then Apply The Picc Mortar Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System Of Dimple Chemicals & Services Pvt. Ltd., This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. After 2 To 3 Hrs Of Wrapping Apply Final Coat Of Duraguard When Surface Is Tacky. This Coats Will Give The Thickness Approx. 350 Micron, As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System, Kelox Rb5050 & Kelox Rh4040 This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As Abrasion & Impact Resistance Followed By Top Coat With Bituminous Epoxy. This Coating Gives Better Performance As Compare To Coatings Specified In Is 10221 . Apply 2 Coats With A Thickness 1Mm ( Bituminous Epoxy + Duramesh+ Bituminous Epoxy ) As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) After Primer Application Final Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System Kelox Rb 5050 Kelox Rh 4040, This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Apply 2 Coats With A Thickness Of 300 Micron On Prepared Metal Surface Etc. It Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance, Corrosion Protection Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface . Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. Also Reduces Frictional Resistance To Flow Of Water. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Water Proofing Of Swimming Pool -- Providing And Applying Impermeable, Monolithic Application, Uv Resistant, Self Curing, Non Toxic, High Compressive Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Which Consists Of Nicomix Series + 53 Grade Cement + Water Of Dimple Chemicals & Services Pvt. Ltd.For Resurfacing The Concrete Surfaces Of Swimming Pool To A Thickness Upto 10 Mm Or As Per Surface Condition And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. By Removing Loose Material, Dust Particles, Grout Slurry By Breaking It With Manual / Mechanical Means. Removing Of Existing Embedded M.S. Bar If Any, Cleaning The Lift Joints, Honey Combing Areas And Entire Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removal Of Algae - Fungi Followed With High Pressure Water Jet. Apply Bond Coat Named As Kelox R 101 + Kelox H 404Which Is Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. Before Picc Application For Suitable Bond Between Old Surface To New Picc Mortar And Then Do The Picc Application Providing With Top Coat Of Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd. After Finishing, Complete As Per Specification Including Materials, Machinery, Labour , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Durabond Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique Blend Of Organic And Inorganic Materials Consisting Ceramic Ironite, Active Ceramic, Cement And Water Miscible Modified Epoxy. As This Contain Water Miscible Epoxy, Can Be Applied On Wet Surface With Better Bond Strength Between Old Concrete And Waterproofing Coating Material For External Surface Of Building. Crack Filling Will Be Done By Duraguardof Dimple Chemicals & Services Pvt. Ltd, Having Cold Weldling Properties Which Cn Stick Anything To Anything. Surface Cleaning Is Done To Remove Loose Material, Dust Particles By Breaking Using Manual And / Or Mechanical Means, Cleaning The Cracks, Small Potholes And Surface Preparation Will Be Done With Special Chemical Name Steripure 10Of Dimple Chemicals & Services Pvt. Ltd For Algae- Fungi Removal And Then Clean It With High Pressure Water Jet, Then Applying A Durabond Of 2 Coats A Special Type Of Coat Suitable To Bond Old To New Concrete Finishing, Complete As Per Specification Including Materials, Machinery, Labour, Scaffolding , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Duraclean Od Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Emulsification & Dispersion Of Oil And Grease Spilled On Any Surface ( Concrete, Metal Or Water ) .Apply By Brush Or Spray On The Surface To Be Cleaned, Wait For About 5 – 10 Minutes, Wash The Surface With High Water Presure Jet.Repeat Process For Heavy Spillage And Surfaces Soaked In Oil Till It Is De-Oiled. Wait For 24 Hrs And See Whether The Penetrated Oil Comes Out To The Outer Surface, If Yes Then Repeat The Step 2-4. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Water Proofing Of Water Tank -- Providing And Applying Impermeable, Uv Resistant, Self Curing, Non Toxic, High Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces Of Water Tank To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. Is To Be Done With Picc By Removing Loose Material, Dust Particles, By Breaking Using Manual And / Or Mechanical Means, Removing Of Existing Embedded M.S. Bar If Any, Cleaning Of Lift Joints, Honey Combing Areas And Surface Is To Be Done Using Special Chemical Named Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Algae- Fungi Removal Followed By Compressed Water Jet. Apply Primer Coat Name Kelox R 101 + Kelox H 404 A Water Miscible Epoxy Of Dimple Chemicals And Services Pvt. Ltd. Before Picc Application. Kelox Is A Bonding Agent Between Old To New Concrete Mortar. Top Coat Will Be Done With Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd., Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Impermeable, Anti-Wear Coating On Concrete & Bitumen Road :- Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. Having High Abrasion Resistant, Anti-Skid, Impermeable, Non Shrink, High Compressive Strength, For Concrete And Bitumen Road Coating Etc. Including Cleaning Of Concrete / Bitumen Road Surface By Wire Brush, Water Jet, Air Blower Etc. ( Using Other Mechanical / Manual Means ) To Remove Existing Loose Particles, Dirt Etc. Then Do Bituminous Coating By Taking Kelox Rb 5050 Of Dimple Chemicals & Services Pvt. Ltd.In A Clean Container & Add Kelox Rh 4040 Of Dimple Chemicals & Services Pvt. Ltd.In It, Apply This Mixture By Wiper On The Cleaned Surface.Top Coat Is Done Using Ready To Use Product I.E. Nicomix Butacoat Of Dimple Chemicals & Services Pvt. Ltd. , After Bituminous Epoxy Coating Immediately Sprinkle Nicomix Butacoat On Bituminous Epoxy Coating To Provide Impermeable, Antiwear & Antiskid Surface. After 10-15 Min, Use Roller On Top Coat I.E. On Nicomix Butacoatfor Compaction. After 6 Hours, Coated Surface Is Ready To Take The Load Of Traffic Movement, Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. An Impermeable, Excellent Bonding With Old Surface, Non Shrink Repair Coating For Concrete Terrace & Etp Plants Includs & Steel Structurebituminous Coating By Taking Kelox Rb 5050 In A Clean Container & Add Kelox Rh 4040 In It, Stirr Well To Get Homogeneous Mixture, Apply This Mixture By Brush Type Wiper On The Cleaned Surface I, E Dust And Loose Partical Free, No Algae Fungi, Non Oily Surface, Corrosion Free Etc. Bituminious Epoxy Coating Is A Two Pack System Consist Of Kelox Rb 5050 Is A Blend Of Bitumen Emulsion With Epoxy Resin And Kelox H 404 Is A Modified Hardener.It Ensures Strong Adhesion With Any Substrate Like Concrete Road, Bituminous Road, Metal, Wood Etc. Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing& Applyinghigh Abrasive Resistant, Impermeable , High Strength, Non Shrink, Self Curing Poly Ironite Ceramic Cementatious ( Picc ) Of Dimple Chemical Services And Pvt Ltd, Which Consists Of Nicomix Series + 53 Grade Cement + Water I, E Piccmortar Mixing With Water Misible Epoxy I.E Kellox R 101 + Kelox H 404 Of Dimple Chemical Services And Pvt Ltdin The Ratio Of 80:20 ( Picc:Epoxy ) And Fill Thecracksfor 10 Mm Width & 10 Mm Depth With 1 Rmt Lengthon The Concrete Surface Ofroad, Industrial Floor Etc, Including Cleaning Of Cracks ( Using Manual / Mechanical Means ) , Power Tool Cleaning, Clean With Special Chemical Steripure 10 Of Dimple Chemical Services And Pvt Ltd For Alge Fungi Removal & Duraclean Od Of Dimple Chemical Services And Pvt Ltd For Oil Removalwith High Pressure Water Jet, Apply Bond Coat Of Water Misible Epoxy Of Keloxbefore Picc:Epoxy Application And Finishing, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts And Any Other Incidental Charges As Directed By The Engineer In Charge. ( As Per Data Rate ) , Providing And Applying Duraclean Wr Of Dimple Chemicals & Services Pvt. Ltd. An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By Washing Or Mopping. Mesure Burr On The Surface, Spray Duraclean Wr On Surface To Be Cleaned, Wait For 5-10 Min And Then Wash It Off With High Pressure Water Jet. Again Mesure Burr On The Surface, Repeat The Process Till Burr Is Below 25 Micron Or 10% Of The Orignal Burr. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Clonon Of Dimple Chemicals & Services Pvt. Ltd. Clonon Is A Revolutionary Product Forbroad Spectrum Odour Remover.Clonon Contains A Proprietary Combination With Major Ingredilents Like Active Lodophor Solution, Benzalkonium Chloride Glutaraldhyde And Others, Clonon Product Main Features Of Odour Remover, No Added Fragrance , Debonds Nano Particles From Surface, Bacteria Killer, Quik Action, Non Toxic Chemicals, Ready To Use, No Stain And Residue , Does Not Contain Formaldehyde, Biodegradable Environmental Friendly.Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Laying In Situ Cement Concrete M -30 With Tremix Treatment For 200 Mm Thickness For Concrete Road With Uniform Sprinklingthe Nicocil R 90 Of Dimple Chemicals & Services Pvt. Ltd Using Travelfor Surface Hardening , High Abrasion Resistance And Low Porosity.Also Is Includinglaying Plastic Sheet For 125 Micron Thickness With Groove Cutting Of 4 Mm Wide And 20 Mm Deep With Necessary Refilling With Polysulphidesealant ( Pouring Grade ) Confirming To Bs : 5212 - 1989 Into Sawed Groove Widened At Top For Sealant Reservoir Of Specified Size And Shape As Per Detailed Drawing Including Fixing Polyethylene Foam Backer Rod Of Required Diameter ( Excluding Reinforcement ) With Coarsen And Fine Aggregate Using V.S.I.Qualityartificial Sand Etc. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges As Directed By The Engineer In Charge. ( Note- Construction Of Concrete Road As Per Instruction Of Engineer-In-Charge Or Requirement, Rate Of Construction Not Included ) , Providing And Applying Steripure S 30 Of Dimple Chemicals & Services Pvt. Ltd. Is Antibacterial, Antifungal Water Base Solution To Remove Algae-Fungi From Concrete , Masonry , Metal, Stone, Tile , Wood, Paver Block And All Composite Material Surface. Spray Steripure S 30 ( Prepar Dillusion In 1 Part Steripuri S30 : 9 Part Water ) On Surface To Be Cleaned, Wait For 15 - 20 Mins Then Wash The Surface With High Pressure Water Jet. This Unique Product Kills The Roots Of Algae-Fungi Which Can Be Removed From Surface By High Pressure Water Jet Cleaning. Re-Growth Of Algae-Fungi Is Stopped Due To Removal Of Roots. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge. , Providing And Laying Of Rumble Strip Usingplastirib 2K 2 Component Cold Plastic Road Marking Material In Single Monolithic Application To Create Rumble Strip Raised Section 15 Mm - 20 Mm High , 200 To 300 Mm Wide And Spaced About 1 Meter Centre To Centre Of Roughly 6 Numbers At One Location, Across The Entire Carriageway. Each Rumble Marking Shall Be Made Complete With Drop On Solid Plus Reflective Glass Beads @ 350 Gm / Sqm Spread Throughout The Surface Of Marking. The Finished Surface Shall Be Levelled, Uniform , Free From Straks And Holes Including Surface Cleaning And Cost Of All Materials Etc. Complete. As Per Irc 99, These Rumble Strips Shall Be Applied As Traffic Calming Measure. , Kerb Stone / Vertical Surface Painting With Reflective Paint, Make Grade 1 ( As Per Is 164 ) Water Based Acrylic Paint, Preferably Mechnical Application For One Coat Priming Coat And 1 Uniform Retro Reflective Finish Coat In Required Colour. Yellow Retroreflecive Coat Shall Be Bright Yellow During Night With Minimum Rl ( Dry ) > 375 Mcd / M2 / Lux White Retroreflective Coat Shall Be Bright White During Night With Minium Rl ( Dry ) > 450 Mcd / M2 / Lux .Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Providing And Applying 2 Component Cold Plastic Night Glow Paint Rolled On Surfacing Material Solvent Free, High Build Two Pack Seamless, Tough, Skid Resistant, Material Which Has Property Of Attaining 600 Microns Thickness In Single Coat Application White ( Or As Required Colour ) Based On Glass And Colour Retaining Acralic Cross Linking Resin System For Coloured Road Surfacing Including Surface Cleaning And Cost Of All Material Etc. Complete. ( All Inclusive On Bitumen Or Concrete Surface ) Night Glow Paint Shall Preferably Be Roller Applied. After Glow Finish Surface Shall Provide Minimum Of 8 Hrs Glow After Fully Absorbing Ambient Light ( Visibile Light Or Uv Light ) For 15 - 30 Min. Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On - Bituminous Surface Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On- Concrete Surface With Application Of Special 2 Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Supplying And Fixing Of High Performance Moulded Shank Raised Pavement Marker / Cats Eye Made Of Reinforced Polycarbonate And Weather Protected Ip > 68 Abs Moulded Body Having 2 Compartment Scratch And Abrasion-Proof Prismatic Polycarbonate Lens Capable Of Providing A Total Internal Reflection Of The Light Entering The Lens Face And Shall Support A Load Per Wheel ( Per Axle ) Of 20000 Kg And Per Axle 40000 Kg Tested In Accordance To Astm 4280D & En 1463-1 And En 1463-2 And Morth. The Dimensions Of The Pavement Marker Being 100 X 100 X 18 Mm And Weight 140Gm, Pin 55 Mm Depth Dia 13 Mm In Star Shape For Better Gripfixing Will Be By Drilling Holes On The Road For The Shank To Go Inside, Without Nails And Using Cold Plastic-Based Adhesive As Per Manufacturers Recommendation And Complete As Directed By The Engineer. The Contractor And Manufacturer Shall Submit A Minimum 1 Yr Installation Warranty And 2 Years Reflectivity Warranty For Satisfactory Field Performance. , Supplying And Fixing Of Solar Road Studs ( High Performance ) Polycarbonate Body, Pavement Surface Mounted Compliant Withen1463 Part 3 Havinguni-Direction Or Bi-Directional With Solar Powered Led Illumination And Reflective Panel Having 1 ) Dimensions 115 X 100 X 8.5 Mm 2 ) Marker Shall Support A Load Of 20 Ton Tested In Accordance To En 1463 . 3 ) Waterproof And Dust Protection Ip > 68 4 ) Weight 117 Gram 5 ) Fixing Using 2 Coponent Cold Plastic Based Adhesive / Butyl Tape Or As Reccomended By Manufacturer 6 ) Working Temperature: Up To 80 Deg. C 7 ) The Contractor And Manufacturer Shall Submit A Technical Warraty Of 1 Yr. , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture And With Approved Stencil Pattern Following By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture Without Any Pattern ( Plain ) And Followed By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing And Fixing 50 Mm Thick Door Shutter Using 25 Block Board 10 Mm Ply On Either Side Of Block Board , 4 Mm Thick Veneer On One Side With Melamine Polish And 1 Mm Thick Laminate On Other Side , Ss Hinges ( Brass ) 125 Mm , Tower Bolt 380 Mm , Mortise Lock , Concealed Door Closer Including Necessary Teak Wood Bedding , Fevical , Screw & Labour For Fixing Etc Complete As Directed By Engineer In Charge , Providing And Fixing 50 Mm Thick Main Entrance Door Partly Panelled And Partly Glazed Door Using 25 Mm Block Board , 10 Mm Ply Garjan On Either Side , Teak Wood Beading Covered With On Side 4 Mm Thick Rich Veneer With Melamine Polish, Floor Spring , Concealed Lock , 1.2 M Handle Pair Of 25 Mm Dia , Glass Pannels Of 0.40 X 0.40 Including Necessary Fevicol , Nails Screw And Labour For Fixing Etc Complete , Providing And Fixing High Quality Inter Locking Concrete Cobble Stone Finish Pavers In Circular Form Having Area Of 1.218 Sqm ( Approximately 71 Or 74 Nos. In One Circle ) , Made By Using Rubber Moulds Of 60 Mm Thickness, Tested And Certified By Csir-Cbri Of Having Strength Of 500 Kg / Sqm. Pavers Should Have 10 Mm Face Layer In White Cement With Pigment Of Lanxess Or Tata Make And Base Mix In M40 Grade Concrete. The Pavers Should Be Made Available In Various Sizes To Make A Circle Of Approved Finish And Design Of Standard Make On A Bed Of Crushed Sand Of 25 To 30 Mm Thick Including Skirting Joints And Cleaning As Directed By Engineer Incharge Etc. Complete. Prior Approval Of Superintending Engineer Will Be Necessary . , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size600 Mm X 450 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Glass Bricks Of Size 190 Mm X 190 Mm X 80 Mm Fitted Inside Already Prepared Ss / Ms Fabrication Using Silicon Glass Sealant Before Placing Of Bricks And After Placing Of Bricks To Create A Bond Between Fabrication Material And Glass Bricks, Finishing The Surface By Filling The Gap Between Glass Bricks With White Cement Etc. Including Loading And Unloading Of The Material As Directed By Engineer In Charge. , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.65M*0.35 ) . , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.25M*0.35 ) . , Providing & Fixing Ester Resin Material 5Th Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflective Sheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 1St Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflectivesheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 200 Mtr Structure As Per Irc-26-1967 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessoriesfor Fixing Structure Excavation Of 0.60 X 0.60 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Milling Of Bituminous Pavement Upto Depth Of 50 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead Charges Of 10 Km As Directed By Engineer In Charge , Milling Of Bituminous Pavement Upto Depth Of 100 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Dismantling Of Rigid Concrete Pavement Upto Depth Of 50 Mm Using Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Re-Texturing Of Rigid Concrete Pavement Upto Depth Of 20 Mm Using Cold Milling Machine With Fine Milling Drum Of Width 1.5M Or Above Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Providing And Fixing Stainless Steel ( Grade 304 ) Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainlesssteel Nuts And Bolts Complete, I / C Fixing The Railling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixingh Accessories Such As Nuts, Bolts, Fasteners Etc. ) . , Providing Concrete Surfacing System With Deck Crs With Base Coat, Application Of Pattern In Stencil Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing Concrete Surfacing System With Deck Crs With Base Coat Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixingchevron Sign Boards In Rectangular Size Of 500X600 Mm Made Out Of ___Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 3.45 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 500X600mmmade Out Of 3Mm Aluminium Composite Material With 0.25Mm Skin Thickness On Either Side , Providing And Fixing One Way Hazard Marker Sign Boards In Rectangular Size Of 300X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 300X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing Two Way Hazard Marker Sign Boards In Rectangular Size Of 450X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge.450X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Encasement Of Columns And Beams By Placing 75 To 100 Mm Thick Free Flow High Strength Micro Concrete With Leak Proof Shuttering With All Equipments, Manpower Etc Complete , Providing And Applying Epoxy Mortar Epibond 11 In Areas Of Fixing Cracks, Charges For Repairing Of Full Depth Crack ( 30Mm Depth X 50Mm Width / Per Rmt ) On Pqc Pavement Using Cross Stitching Method As Per Specification Of Irc Sp : 83-2008. Making Chase Along Crack And Cleaning The Holes / Chase With Oil Free Compressed Air, Fixing Of Reinforcement In Holes Filled With Epoxy Resin In Enough Quantity For The Bar To Be Completely Coated When Inserted In The Hole, Chase Filling With Epoxy Epibond 11 ( 1:1:8 ) Resin+Hardner+Fine Sand As Per Manufacture Specification, Curing, Transportation, Required Machinery, Tool And Tackles Etc.Complete As Per Direction Of Eic. , Providing And Applying Volatile Corrosion Inhibiting Wax Powrthrow Ht Wax On Ht Lrpc Strands Before Embedment In Tendons, Lrpc Strands Of 12.7Mm & 15.2Mm , Tendon Duct Need To Be Lime Washed Prior To Insertion Of Lrpc Strands Coated With Wax. The Wax Must Be Hand Applied Using Gloves From The Pail Prior To Insertion On Strand In Duct. Powrthrow Ht Wax Is Bipolar In Nature Should Protect The Strand From Corrosion. As Per Jis Z 1535M Method Should Have Excellent Resistance To Corrosion Spots. And The Wax Should Show A Potential Change Of Minimum 120Mv As Per Corrosion Potential Test.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
18.
Health and Family Welfare #10772037 Price Bid
Supply Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Pcc Concrete Flooring 1:2:4 At Floor Stand ( 1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safetylock Size 900Mmx2000mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gaugeshelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments:Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Pcc Using 40Mm Broken Stone ( 10Cm Thick ) , Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Pcc Bed With Cement Mortar 1:4, 12Mm Thick, ( The Finished Inside Dimension Shall Be 300X300x300mm ) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required.4.00 Mm Copper Conductor ( 8 Swg ) , Door With Hinges And Emergency Safetylock Size 1000Mmx2000mmas Per Spec ( Not Taken For Evaluation ) , Emergency Alarm Cable Additional Requirement ( Hooter ) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards:Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator / Rccb / Rcbo As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplyand Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection ( Rccb ) As Per Specification As Required4 Pole 63 Amps. ( 415 Volts ) , 100Ma Sensitivity , Supply And Fixingof Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required.6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixingof Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required.6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date.4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date.3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium / Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
19.
Educational and Research Institute #10575911 Price Bid
Supply Of Coronary Engiography Kit And Its Related Consumables , Group A: Coronary Angiography ( Items Used In Cath Lab ) , ( A ) Angio Guidewire Hydrophylic 0.035 / 0.023 – J / 0.032 J-Tip 150 Cm - Us Fda And Japan Pmda And Dcgi Approved ( B ) Angio Guidewire Hydrophylic 0.035 / 0.023 – J / 0.032 J-Tip 260 Cm - Us Fda And Japan Pmda And Dcgi Approved , Angio Guidewire 0.035 – J / 0.032 J-Tip 150 Cm Translumina Or Equivalent , Angio. Cath. Al1 / Al2 / Al3 – 5F, 6F , Angio. Cath. Ar1 / Ar2 / Ar3 – 5F, 6F , Angio. Cath. Jl -3.0 / 3.5 / 4.0 / 4.5 / 5.0 ( 5F & 6F ) , Angio. Cath. Jr. 3.0 / 3.5 / 4.0 ( 5F & 6F ) , Angio. Cath. Pigtail 4F / 5F / 6F , Ima - 6F / 7F , Multipurpose6f, 7F , Peadiatric Input Sheath 4F / 5F , ( A ) Radial Sheath 5F / 6F- Us Fda And Japan Pmda And Dcgi Approved ( B ) Femoral Sheath 5F / 6F-U Us Fda And Japan Pmda And Dcgi Approved , Two Locking Mechanism ( A ) Snap On / Click Off ( B ) Rotating Type. Have Unique Intro Cross Cut Valve Which Maintain Uncompromised Hemostasis To Avoid Bleeding.Radial Sheath 5F / 6F Or Equivalent , Tiger 5F / 6Fcatheter- Us Fda And Japan Pmda And Dcgi Approved , Tiger 5F / 6F Catheter Equivalent Tig 2 Inner Diameter To 0.050 With Maximum Pressure Upto 1200 Psi. , Angiographic Catheter – Tig Curve Comprised Of A Two-Layer Construction, Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers. •Must Have 32 Strands Of Stainless-Steel Braid. •Must Have The Shaft Inner Layer And Outer Layer Contain Barium Sulphate. •Must Have Anti-Kinking Protector Sleeve, With Non-Braided Tip Shaft ( Distal -2 Cm ) . •Trans Radial Catheter Must Have Shapes Designed To Cannulate Left And Right Coronary Arteries Tig, Tig Ii, Jacky, Sarah. •Must Be Available In 4F, 5F, 6F Sizes •Must Have Inner Diameter Of 4F = 1.03Mm, 5F= 1.20Mm, 6F = 1.30Mm •Usfda And Pmda –Approved , Dye ( Non-Ionic Contrast Agent 100Ml It Should Be Us Fda / Ce & Dcgi Approvediohexol As Salt Name With 350 Mg / Ml Concentration , Iodixanol As A Salt Name 320Mg / Ml With Plastic Bottle With Hanger 100Ml Pack , ( A ) Femoral Sheath 5F / 6F / 7F / 8F / 9F / 10F / 11F / ( B ) Femoral Long Sheath 30 To 50 Cm , Unilock Syringe 10 Ml , Iv Cannula ( 18, 20, 22 G ) , Disposable Ecg Electrodes For Adults- Us Fda / Ce & Dcgi Approved • Adult Diaphoretic Foam Electrodes. • Should Be Pre-Gelled, Peel And Stick Electrode With Excellent Adhesion • Should Have No Residue Once Removed Should Conform To Or Exceed The Highest Industrial Standard For Ecg Electrodes, Quality Certification From Authorized Agencies To Be Provided , Cd – R Media With Atleast 700 Mb Storage And Atleast 52X Recordable Speed Dvd , Pressure Monitoring Line 200Cm , Manifold ( Two Port ) ( Right On ) , High Pressure Line - 200 Cm , Dvd , Docking Wire , Swan Ganz Catheter - Ce Approved - 6F / 7F Us Fda / Ce And Dcgi Approved , Gadoteric Acid 10 Mlvial With Usfda Approved , Gadotericacid20 Ml Vials With Usfda Approved , Radial Artery Haemostasis Device- ( T.R. Band ) Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Must Have Belt Magic Tape For Fast Application •Must Have Curved Support Plate. Must Have Green Positioning Marker. •Must Be Available In 2 Sizes – 24Cm And 29Cm Usfda+Pmda Approved• , Special Slender Sheath ( Gss ) Must Have Unique Thin Wall Technology Reducing The Outer Diameter By 1• Fr Size Whilst Maintaining The One Size Lager Inner Diameter. Must Have 7Fr Sheath With Outer Diameter Of 2.8Mm, 6Fr With Od Of• 2.46 Mm & 5Fr With Od Of 2.13Mm. Hydrophilic M Coating With 20 / 21G Surflash Needle And Tif Tip• Technology Which Provide Optimal Tapering Design. Usfda / Pmda Approved• , Group B: ( Consumable For Ptca ) , ( A ) Judkins Guiding Catheter ( Jr Jl & Pigtail Ebu, Routine And Sidehole Catheterxb, Xbr ( Terumo, Cordis, Meditronic, Boston Scientific, Translumina ) Or Equivalent Qualityus Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French Size Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Special Guiding Catheter – Ikari Curve •Must Have Ikari Curve For Radial Route. •Must Have Stainless Steel Flat Wire Braid •High Strength Wired Braided Catheter With Inner Layer Of Ptfe With Fluoropolymer. •Must Have Zone Technology - Five Zone Each Fabricated From A Material Of Different Stiffness. •Must Have Larger Lumen.6Fr Id - .071 •Usfda / Pmda Approved , Ptca Inflation Device – Us Fda Approved , Nih Catheter Us Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. , Cournard Guidingcatheter Us Fda / Ce & Dcgi Approved • 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. , Double Lumen Thrombo-Aspiration Catheter , ·Swan Ganz Catheter , Vascular Closure Device With Bio Absorbable Pga Suture That Provide A Secure Seal, , Bioabsorbable Collagen Designed To Conform To The Arteriotomy For Confident Closure, And Low Profile Bioabsorbable Anchor ( 50:50 Blend Glycolideandlactidepolyer ) To Fit Closely Against Arterial Wall Leaving Blood Flow Undistributed While Maintaining Vessel Diameter. Againt . , Ptca Inflation Device- Us Fda / Ce & Dcgi Approved • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design. , ( A ) ( Haemostatic Y-Connector ) For Ptca – Push Mechanism - Us Fda / Ce & Dcgi Approved • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi-Open And Closed Position ( B ) Ptca Y Connector 400 Kpa Leak-Proof Seal From Proprietary Designed Valve, *7F-9F Compatible Lumen Allowing Delivery Of Wide Range Of Devices And Torque And Introducer Fit 0.014-0.021 Guide Wire. , Hydrophilic Guidewire With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. •One Piece Construction & Radiopaque Polyurethane Jacket. •Must Be Available In Standard And Stiff. •Must Be Available In .035, .032, .038, .025, .018 Diameter And 260 Cm Length - Straight / Angled / 1.5 Mm J Shape •Usfda And Pmda Approved , ( A ) Baby J Wire With 1.5Mm J Tip – 180 Cm And •Baby J Curve Must Have Radius Of 1.5 Mm. •Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, •One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. •Must Have Tungsten-Infused Polyurethane Jacket. •Usfda And Pmda Approved ( B ) Baby J Wire With 1.5Mm J Tip – 260 Cm And •Baby J Curve Must Have Radius Of 1.5 Mm. •Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat, •One Piece Construction For 1:1 Torque & Radiopaque Polyurethane Jacket. •Must Have Tungsten-Infused Polyurethane Jacket. •Usfda And Pmda Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 28Cm Tip Load 0.7 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 20Cm Tip Load 0.5 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” On E Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 22Cm Polymer Sleee Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 0.8 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014” On E Piece Core Workhorse Wire With Jointless Spring Coil 22 Cm Polymer Sleev Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 1Gm 180 Cm Length Tip Radiopacity 3 Cm , Extra Support 0.014Wire; 0.7 Gf Tip Load Tip Radio Opacity 4 Cm 180 Cm Length Ptfe Coating Over The Shaft Silicone Coating Ovr Spring Coil , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Polymer Jacket With Sion Technology Having Comosit Core With Actone Inside Length 28 Cm With Tip Load 0.8 Gm 180 Cm Length Tip Radiopacity 3 Cm , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Polymer Jacket With Sion Technology Having Comosit Core With Actone Inside Length Tip Radiopacity 3 Cmwith Tip Load 0.5 Gm , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Tapering To .009” 0.8Gf Of Tip Load; 16 Cm Plymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, 190 Cm Length Tip Radiopacity 16 Cm , .014 One Piece Core Cto Wire With Jointless Spring Coil Ptfe Coating Over The Shaft, Tip Load 3G, Tip Load 3G, 4.6 G And 12G, 180 Cm Length With Tip Radiopacity 11 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 9G 180 Cm Length Tip Radiopacity 20 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 12G 180 Cm Length Tip Radiopacity 20 Cm , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .008” Tip Load 20G 180 Cm Length Tip Radiopacity 17 Cm , .010” One Piece Core Wire With Joint Less Spring Coil Length 15 Cm Cone Tip With A Tip Load Of 3.5 Gm 190 Cm Length Tip Radiopacity 15 Cm , Ptca Guide Wire – Core Material Elastinite Nitinol For Excellent Flexibility And Durability, Shaping Ribbon For Excellent Shape Retention And Atraumatic Tip Load Less Than 0.65 Gm With Regular Length, Regular Shaft Support And Floppy Tipus Fda / Ce & Dcgi Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. Us Fda / Ce & Dcgi Approved , Ptca Guide Wire – Exchange Length Us Fda / Ce & Dcgi Approve , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. Us Fda / Ce & Dcgi Approved , Ptca Guide Wire – Hydrophilic Coated, Exchange Length Us Fda / Ce & Dcgi Approved , Ns Ptca Wire Floppy. Extra Floppy Intermediate & Hypercoat Including Cto Wires .014Diameter Ptca Wires With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission Available In Various Tip Loads- Us Fda And Japan Pmda And Dcgi Approved , Extra Floppy Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 / 300 Cm Length •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have Ptfe Coating From 25 To 180 Cm Length. & Mucus Coat Hydrophilic Coating Up To 248 Mm •Should Have 0.6-Gram Force Tip Loads •Usfda+Pmda , Floppy Tip Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 248 Mm, & Ptfe Coating From 25 To 180 Cm Length. •Should Have 1 Gram Force Tip Loads •Usfda+Pmda , Hypercoat Ptca Guide Wire With 9.7-Gram Force Rail Support– Mucus Coated Hydrophilic Distal Tip, 0.014” Diameter And 180 / 300 Cm Length •Must Have Platinum Coil At Distal Tip. 14 Mm Tip Shape Length. •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 250 Mm & Ptfe Coating From 25 To 180 Cm Length. •Should Have 1-Gram Fore Tip Load •Usfda+Pmda , Cto Stiff Ptca Guide Wire - 3.6-Gram Force Tip Load – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length. •Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 248 Mm & Ptfe Coating From 25 To 180 Cm Length. •Should Have 3.6-Gram Fore Tip Load •Usfda+Pmda , Micro Catheter To Be Used For Cto Fine Cross Antegrade And Retrograde Apporch. -Us Fda / Ce & Dcgi Approved , Aspiration Thrombectomy Catheter • Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches • Must Have 1.30 Mm Square Suction Area • Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet, • 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth. • Must Have Distal 40 Cm Hydrophilic Coating. • Pmda And Dcgi Approved , Cto Indicatedsemi-Complaint Balloon With Slim Seal Technology On Distal Tip With Lesion Entry Profile Of 0.017, Crossing Profile Of 0.021 And Single Flexible Tungsten Marker Available In Unique Diameter Of 1.2Mm With Variety Of Lengthsus Fda / Ce & Dcgi Approved , Ptca Balloon ( Non-Compliant ) -Us Fda / Ce & Dcgi Approved • Quote Both Monorail ( Rapid Exchange ) And Otw Balloons • Available In All Sizes From 2 - 4.0 Mm, Variable Lengths Should Have A Very High Rated Burst Pressure , Ptca Balloon Ultra Lowentry Profile Balloon With 0.016 Entry Profile, Thin Marker Of 25Micro Milimeter And Core Wire Shaft For Batter Pushabilty With Widerange From 1Mm To 4Mm Diameter. , Ptca Balloon Semi Compliant Cto Balloon With Ultra Low Entry Profile With 0.40Mm Or 0.016 And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Crossablity Even With Higher Diameter Balloon. , Ptca Balloon Semi Compliant Balloon With Entry Profile Of0.40Mm Or 0.016 Or Execellentcrossablity ( A ) Sirolimus Drug Eluting Balloon With Nano Carriers Ce Marked ( B ) Drug Coated Balloon - Drug Coated Balloon With 2 ?G / Mm2 Dose Of Paclitaxel With Polysorbate& Sorbitol As Carrier Which Will Deliver An Optimal, Therapeutic Drug Dose To The Target Vessel Wall After A Minimum 30 Second Inflation Time. Available In Sizes- 035 Guidewire Compatible – 120 Cm Shaft - 4Mm -6Mm Dia, Lengthupto 150Mm, 035 Guidewire Compatible – 75Cm Shaft – 5Mm – 12 Mm Dia, Length 60Mm, 014 Guidewire Compatible – 150 Cm Shaft – 2Mm To 3.5Mm Dia, Length 120 Mm , High Pressure Ptca Dilatation Catheter With Small Entry Profile Of 0.43Mm And Small Balloon Profile Of 0.034” With Special Silicon Coating On Balloon To Avoid Mellon Seed Effect. • Small Distal Shaft Profile Of 2.5-2.6Mm To Allow Kbt In 6Fr Large Lumen Guiding Catheter. , Lesion Entry Profile - 0.016 / Nominal Pressure - 12 Bars / Rbp - 22 Bars / Impeccable Tip / Hydrophilic Coated / Non-Compliant Balloon / Prime Shaft , Dual Layer / Rbp 35 Bars / Abp 45 Bars / Strictly Non-Compliant , Ptca Balloon ( Semi Compliant ) – ( Usfda Approved ) Monorail, Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size 1.2, 1.5, 1.2 Push, 1.5 Push, 2-4Mm Dia X 8, 12, 15, 20, 30 Lengths , ( A ) Ptca Balloon ( Non Compliant ) – ( Usfda Approved ) Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size - 2-6Mm Dia X 6, 8, 12, 15, 20, 30 Lengths ( A ) High Pressure Non-Compliant Balloon With Innovative Triple Layer Balloon Technology With High Pressure Resistance Of 22 Atm. Must Have Elastomer Outer Layer, Middle Layer Of Polyamide And Inner • Most Layer Of Elastomer. Must Have Nominal Pressure Of 12Atm And Rbp Of 22Atm. •Shorter Thin Distal Tip Of 2.9Mm With Low Entry Profile Of 0.43 Mm. Must Have Hydrophilic Mucus Coating Must Have 3.0 Mm Short Taper Balloon Shoulder& Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile.Must Have 2.6 French Stainless Steel Core Wire Structured Shaft•& Stainlesssteel Stylet In Mid Shaft. Must Have Hypotube Without Ptfe Coating. Must Have Three Pleats Re-Wrappable Structure. Pmda+Ce Approved• , Cto Balloon With Ultra – Ultra Low Entry Profile Of 0.016 Must Have Hydrophilic Mucus Coating. •Should Have Smallest Diameter 1.00Mm And 5Mm Length. •Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile. •Must Have Flexible Tip With Short Balloon Bonding Part Of 0.4Mm. •Nominal Pressure Of 06 Atm And Rbp Of 14 Atm •Must Have 2.4 To 2.7 French Tapered Stainless Steel Core Wire Structured Shaft. •Must Have Three Pleats Re-Wrappable Structure. •Pmda+Ce Approved , Dual Layer / Rbp 35 Bars / Strictly Non-Compliant ( Only 10% Growth ) / Andfor Super High Pressure Ptca, A Manometer Of 55 Atm , Cto Nc Balloon Diameter 0.85 Mm Entry Profile .016 Rbp 21 Hydrophilic Single Proximal Marker. , Dedicated Dual Lumen Micro Catheter For Side Branch Access , Thrombus Aspiration Catheter With Removable Core Wire And 30Cm Hydrophilic Coating From The Tip; Available In 6F And 7F , Semi-Complaint Ptca Balloon With Smallest Entry Profile Of 0.0157, Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating; Available In Lowest Profile 1 Mm Diameter, Longer Shaft Length Of 146Cm. , Non-Compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5Mm Diameter, Longer Shaft Length Of 146Cm. , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Balloon. Ce Approved , Cutting Balloon For Ptca Having Microsurgical Atherotomes ( Blades ) - Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons Available In The Sizes And Lengths , Wire Based Scoring Balloon Cathethr. Us Fda / Ce & Dcgi Approved • Available In The Sizes And Lengths Monorail ( Rapid Exchange ) , Everolimus Eluting Stent. Cobalt Chromium With 60 Microns Strut Thickness. Hydrophilic Coating On 3 Mm Balloon Shaft. Biodegradable Coating Only On Abluminal Side. , Sirolimus Eluting Stent. Cobalt Chromium With 60 Microns Strut Thickness. Hydrophilic Coating On 3 Mm Balloon Shaft. Biodegradable Coating Only On Abluminal Side. , High Pressure Semi Complaint Ptca Balloon Must Have Low Entry Tip Profile Equal To Or Less Than 0.016 Should Have Nominal Pressure 6 Atm Or Above And Rbp Above 14 Atmmust Be Available In Diameter 1.0 Mm Along With Other Size Matrix Starts From Diameter 1.75 Mm To 4 Mm Quote Both Monorail And Otw Balloonus Fda / Ce & Dcgi Approved , Special Ptca Balloon ( Non Complaint ) For Post Dilations Must Have Diameter Strating From 1.75 Mm To 5.0 Mm Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail And Otw Balloonus Fda / Ce & Dcgi Approved , Semi Complaint Balloon - Thin Multi-Layer Balloon, Tri Fold Balloon Design For Good Rewrap, Semi-Complaint Coronary Balloon With Laser Bond Technology On Distal Tip With Crossing Profile Of 0.021”, Tip Entry Profile Of 0.017”, Nominal Pressure Of 8Atm And Rbp Of 14Atm Available In Diameter 1.20-4.00Mm And Lengths 6Mm -30Mmus Fda / Ce & Dcgi Approved , Non-Complaint Coronary Balloon With Tri-Fold Layers And Tip Entry Profile Of 0.018” With Nominal Pressure Of 12Atm And Rbp Of 18Atm. Excellent Flexibility And Tight Rewrap With Flat Compliance For Excellent Stent Apposition, Available In Diameter 2.0-4.5Mm And Lengths In 8Mm-25Mmus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swagging Tip Available In Tiploads Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) Us Fda / Ce & Dcgi Approved , Semi-Complaint Coronary Balloon With Slim Seal Technology On Distal Tip With Crossing Profile Of 0.021”, Lesion Entry Profile Of 0.017” And Microglide Coating Available In Diameter 2.25-5.00Mm And Lengths 6-30Mmus Fda / Ce & Dcgi Approved , Special Ptca Balloon Non-Complaint Coronary Balloon With Multilayer Crossflex Balloon Technology And Round Tip With Lesion Entry Profile Of 0.018” Available In Diameter 1.5Mm-5Mm And Lengths In 6Mm-25Mm With Skive Technology On Mid Shaft Of Dilatation Catheterus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Durasteel Core, Responsease Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tipload Of 0.9Gmus Fda / Ce & Dcgi Approved , Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swagging Tip Available In Tiploads Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) .Us Fda / Ce & Dcgi Approved , Cto Indicated Penetration Guide Wire For Antegrade Wire Escalation ( Awe ) Technique With Unique Micro Textured Tip For Cap Engagement And Tapered Tip For High Penetration Powers. Tip Load 11 To 14 Gm Penetration Power – Above 160 Kg / In2us Fda / Ce & Dcgi Approved , Tuohy Borst ( Haemostatic Y-Connector ) For Ptca Push Pull Mechanism – Us Fda , Amplatz Wire – Ptee Coated – ( Regular Length ) .035 Large Stainless Steel ( Ss ) Core With Ss Flat Wire Coils Gradual Taper With Core To Tip Support And Flexibility For Atraumatic Navigation Through Fortuous Anatomy 150 Cm And 180 Cm Usfda Approved , Group C: Stents , Stainless Steel Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Stainless Steel Coronary Stents, Premounted On Balloon –Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Cobalt Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Cobalt Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Covered Coronary Stents – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Both • Available In The Sizes And Lengths • Covered Graft Stent For Dissectedartery , Stainless Steel Renal Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) • Available In The Sizes And Lengths , Zotarolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Chromium Cobalt Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda / Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Stain Less Steel Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda / Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromium With Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 48Mm With Biogradable Polymer.Us Fda / Ce & Dcgi Approved , Biolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Tacrolimus Eluting Stent - Us Fda / Ce & Dcgi Approved , Drug Eluting Biodegradable Polymer & Shellac Resign Top Coatus Fda / Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link Drug Eluting Stent -Us Fda / Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link 48Mm Drug Eluting Stent -Us Fda / Ce & Dcgi Approved , Everolimus Eluting Platinum Chromium Stent Bio Absorvbale Polymer Stentus Fda / Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromiumwith 2 Links & 8 Crownswith Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 38Mm With Biogradable Polymer And Gradient Coating.Us Fda / Ce & Dcgi Approved , Biodegradable Polymer / Microporous Surface / Sirolimus Drug & Shellac Resign / Abluminal Coating / Temperature Control Device-Tag Alertus Fda / Ce & Dcgi Approved , Dual Drug Polymer Free Stent / Plat Form-Cobalt Cromium / Probucol Drug Instead Of Polymer / Microporous Surface / Abluminal Coating / Shellac Resin / Strut Thickness 79Micron , Sirolimus Coated Drug Stent On Cobalt Chromium - Ce / Us Fda And Dcgi Approved , Silicon Carbide And Sirolimus Drug Eluting Stent – Ce / Us Fda And Dcgi Approved , C.P. Stent Covered , C.P. Stent Uncovered , Drug Eluting Platinum Chromium Coronary Stents, Premounted On Balloon – Us Fda / Ce & Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Available In The Sizes And Lengths , Sirolimus Eluting Cobalt-Chromium Stent With Abluminal Gradient Coating - ( L-605 Co-Cr Alloy ) ( Should Not Have Drug & Polymer Coating On Joints & Bends ) . 2 Links – 8 Crown Design •Bioresorbable Polymer Of Plcl ( Poly Lactic Acid + Poly Capro Lactone Pcl ) With Degradation Time Of 3-4 Months. Should Have Bioinspired Open Cell In Phase Design. •Low Concentration Of Sirolimus ( 0.8Ug / Mmsq ) . •Minimum Tip Entry Profile Of 0.42Mm •Pmda+Ce Approved , Sirolimus Eluting Cobalt-Chromium Stent With Abluminal Gradient Coating - ( L-605 Co-Cr Alloy ) ( Should Not Have Drug & Polymer Coating On Joints & Bends ) . 2 Links – 8 Crown Design •Bioresorbable Polymer Of Plcl ( Poly Lactic Acid + Poly Capro Lactone Pcl ) With Degradation Time Of 3-4 Months. Should Have Bioinspired Open Cell In Phase Design. •Low Concentration Of Sirolimus ( 0.8Ug / Mmsq ) . •Minimum Tip Entry Profile Of 0.42Mm Should Have Gradiant Coating •Pmda+Ce Approved , Polymer Free Evrolimus Eluting Stent Coronary Stent Withco-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016 , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. , Polymer Free Sirolimus Eluting Coronary Stent With Co-Cr Platform Having Microporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016 , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withstrut Thickness 68?M ( Sv ) , 79?M ( Mv ) . , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin With Temperature Control Device - Tag Alert , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withs Strut Thickness 68?M ( Sv ) , 79?M ( Mv ) . , New Generation Des Providing Synergywith Biodegradable Polymer With Microporous Surface. Sirolimus Drug And Cobalt Chromium Surface. , Sirolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns. , Everolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns , Balloon Expandable Pulmonary Artery Stents – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Available In Various Sizes , Ivc Stents Self Expendable - Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Available In Various Sizes , Everolimus Eluting Chromium Cobalt Multi Link Platform Drug Eluting Stent With True Center Tip For Peak Performance In Complex Leasions -Us Fda / Ce & Dcgi Approved , Sirolimus Bioresorbable Vascular Scaffold Stent Systemus Fda / Ce & Dcgi Approved , Ultrathin Strut 50 Micron Cobalt Chromium Everlimus Eluting Coronary Stents , Group D: Consumable For Peripheral Stenting , Distal Embolic Protection Device - Carotid / Svg • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For360 Degree Wall Apposition • Rx .014 6F Sheath Compatible • 190 Cm Extra Supportwire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1Mm Pore Free Zone • Non-Thrombogenic Nylon Membrane With Hydrophilic Coating • Should Allow Optimal Filtration In Vessels 3– 5.5 Mm Size •Usfda Approved , Balloon Expandable Stent - Renal • Should Be Low Profile, 6F Guide And 0.018 Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength At Proximal End For Ostial Lesion • Stent Should Be Premounted On Semi Compliant Balloon Catheter • Stent Dia 4-7Mm, Length 15 & 19, Cathter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Balloon Expandable Stent - Large Diameter • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scafolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10Mm, Length 27, 37, 57, Cathter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Self Expanding Stent For Carotid Artery Stenting • Self Expandingelgilloy Stent With Closed Cell Design • Monorail, 0.014 Wire & 6F Sheath Compatible • Reconstrainable Braided Stent • Shaft Length 135Cm • Dia : 6-9 Mm , Peripheral Self Expandable Stent • Should Be Laser Cut Self Expandingnitinol Stent With Proximal And Distal Markers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility • Stent Struts To Be Electropolished To Avoid Micro Fracture Through Micro Cracks On The Stent Struts • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening • Dia 6 - 14 Mm , Length -20, 40, 60 , 80 , 100 , 120 • Should Be 6F Sheath And 0.035 Wire Compatible Across Sent Size Matrix , Peripheral Self Expanding Drug Eluting Stent • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Months With Lowest Dose Density Of 0.167 ?G / Mm2 For Sfa And Ppa. • Triaxial Delivery System • Hybridcell Architecture With Open & Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia - 6 & 7 Mm • Length -40, 60, 80 , 100, 120 Mm • Us Fda Approved • Laser Cut Nitinol Stentdedicatedly Designedfor Sfa & Popliteal • Trixial Delivery System , Hybrid Cell Architecture, • 6F Sheath Compatibility • Dia5, 6, 7 , 8 Mm , Length -40, 60, 80, 100, 120Mm , 150 Mm • Easy Deployment With Thumbwheel & Pull Grip , Inflation Device To Have High Presure Range Upto 26 Atm To Have High Pressure Stopcock Preventing Leakage During High Pressure Inflation 20Cc Volume Holding , Balloons - Nc Workhorse ( 0.035 Wire ) Should Be Non-Compliant / Semi Compliant. Rbp Of 20 - 24 Atm ( 3-8Mm Balloon ) , 14-18 Atm ( 9-12Mm Balloon ) , Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Nybax Material Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Lubricious Medi-Glide Coating On Balloon Material Should Have Good Re-Wrap And Low Tip Profile Should Be 5F ( 3-7Mm Balloon ) / 6F ( 8-10Mm Balloon ) / 7F ( 12Mm Balloon ) Sheath And 0.035 Wire Compatible Should Have Min Lesion Entry Profile Of 0.040 ( 1.016Mm ) Should Have Choice Of Long Balloon Lengths 20Mm To 200Mm , Carotid / Renal Angioplasty Balloon • Rx 018 Carotid / Renal Balloon • 018 Guide Wire Compatible • 4F Sheath Compatible To 4 To 7 Mm Diameter With 20Mm Length • Usable Catheter Length 135Cm For All Sizes . • Usfda Approved , Paclitaxel Coated Drug Eluting Balloon For Btk Paclitaxel Coating Should Be 2Ug / Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -2-4 Mm , Paclitaxel Coated Drug Eluting Balloon For Iliac & Sfa Paclitaxel Coating Should Be 2Ug / Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -4-7 Mm , Balloons - 0.018 / 0.014 Wire Compatible Should Be 4F / 5F Sheath And 0.018 / 0.014 Wire Compatible With Choice Of Otw / Monorail Delivery System Should Be Non-Compliant / Semi Compliant Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material Should Have Lowest Tip Entry Profile Of Not More Than 0.022 And Good 5 Fold Re-Wrap Design Should Have Bioslide Hydrophilic Coating On Balloon Material Should Have Large Working Range Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Full Length Tapered Core Wire For Enhancdpushability And Kink Resistance Should Have Balloon Lengths Starting From 20 Mm- 150 Mm And Balloon Diameter From 3Mm To 10Mm , Balloon - 0.014 Wire Compatible For Btk Procedure With An Ultra-Low Lesion Entry Profile ( 0.017” / 0.43 Mm ) And Best-In-Class Crossing Profile ( 0.030” / 0.76 Mm ) With Deflation Times Of Less Than 10 Seconds*** And Balloon Lengths Up To 220 Mm Balloon Dia From 1.5 Mm To 4Mm With 4 F Sheath Compatibility Across Sizes. Monorail / Over The Wire. , Balloons - Large Diameter For Vessel Diameters Of 12Mm And Above Should Be Non-Compliant And Have Low Deflation Time Balloon Material Should Be Lubriciously Coated With Scratch / Puncture Resistant Balloon Material Min. Sheath Compatibility Of 7F. , Peripheral Cutting Balloon Should Have Choice Of Diameter Range From 5Mm To 8Mm Should Have Micro Surgical Blades ( Atherotome ) On Non Compliant Balloon Only Bigger Diameter Cutting Balloons ( 5 - 8Mm ) With 2Cm Atherotome Should Be 0.018 Wire Compatible With Otw Delivery System Exposed Atherotome Height To Be Not More Than 0.005 , Occlusion Balloon Should Be Soft Compliant Balloon Material With Radiopaque Markers At Both Distal And Proximal End Of Balloon Should Be 14F / 16F Sheath And 0.035 / 0.038 Wire Compatible With Balloon Diameter Of 20Mm, 27Mm, 33Mm And 40 Mm , Guidewires - 0.018 / 0.014 Should Have Glidex Hydrophilic Distal Coating For Negotiating Tortous Anatomy And Colateral Approach. Should Be Available In Both 0.018 And 0.014. Should Provide Excellent Support Like A 0.035 In A 0.018 / 0.014 Wire Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Amplatz Super Stiff Wires - 0.035, 0.038 Should Have Stiff Core, Super Stiff Wire Body, Atraumatic Tip With Gradual Distal Core Taper Should Have Ptfe / Teflon Coating For Reduced Friction During Catheter Tracking. Should Support Catheter Exchange Should Have Flat Coiled Outer Wire Construction For Larger Inner Core And Hence Greater Support , Hydrophilic Marker Wire - 0.035 Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating 4 Distal Paltinum Magic Markers Spaced At 1Cm For Improved Visualization Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Cto Wire 0.014 0.014 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm , 18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , Cto Wire 0.018 0.018 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm , 18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.014 Peripheral Wire Stainless Steel Core Wire Hydrophilic & Hydrophobic Coating Tip Load-3Gm & 6 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.018 Peripheral Wire 0.018 Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load- 7.6 Gm , 6.5 Gm Us Fda Approved Wire Lengths -150 Cm , 200 Cm & 300Cm , Backup Meir Wire - 0.035 • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Sholud Have Choice Of J And C Tip Shape With 185Cm And 260 / 300Cm , Guide Catheters - 6F, 7F, 8F Choice Of 16 Tip Shapes Amongst Indusry Standard Shapes In 55Cm And 90Cm Should Have Excellent Backup Support And Shape Retention Tungsten Atraumatic, Radiopaque Soft Tip Should Have Round Double Wire Braided Construction For Better Torque, Large Inner Lumen With Soft Tapered Tip Ptfe Inner Liner ( For Smooth Passage Of Devices ) And Polyether-Ester Polymer Outer Coating ( For Shape Retention ) , Support Catheter Catheter For Crossing Chronic Total Occlusions In Peripheral Arteries- Fda / Ce Mark Approved Various Sizes , 0.014 , 0.018, 0.035 , Micro Punture Set Accustick Ii Introducer ( 4F Coaxial Dilator / 6F Sheath With Ro ) With Locking Stiffening Cannula Anddiagnosticneedle With Stylet 21G + 0.038 J -Tip And 0.018 Nitinol Wire , Detachable Coil 0.018 Interlock Detachable Platinum Fibered Coil For Peripheral Use , 0.018 Assorted Sizes .Dia 3Mm -14 Mm . Assorted Lengths , Detachable Coil 0.035 Interlock Detachable Platinum Fibered Coil For Peripheral Use , 0.035 Assorted Sizes Dia 3Mm- 20 Mm, Assorted Lengths , Pushablevortx 18 Coil Pushable 0.018 System Platinum Vortx Coils 3 To 6 Mm In Diameter Of Assorted Length , Pushable18 Coil Pushable Platinum 0.018 System Coils, 3-6 Mm Diameter Of Assorted Lenghts , Pushablevortx 35 Coil Pushable Platinum Vortx0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pushable35 Coil Pushable Platinum 0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pva Particle Polyvinyl Alcohol Particles 350-500 Microns , Pva Particle Polyvinyl Alcohol Particles 500-700 Microns , Pva Particle Polyvinyl Alcohol Particles 150-250 Microns , Pva Particle Polyvinyl Alcohol Particles 45-150 Microns , Drug Eluting Beads D C Bead - Loadable Hydrogel Microspheres That Are Biocompatible, Hydrophilic, Non-Resorbable, And Precisely Calibrated And Approved For Loading With Doxorubicin And Irinotecan, Available In Size Range Of 70Um - 700Um. , Torquable Pre Shaped Superselectivemicrocatheter Torquablemicrocatheter For Peripheral Embolization, Made Of Nitinolhypotube And Hydrophilictip. Id 0.021 With Different Shapes. ( Bern, J, Swan & Strait ) , Microcatheter For Peripheral Embolization Stainless Steel Braided Microcatheter With Hydrophilic Coating For Peripheral Coil Embolization. Id 0.021 Manually Shapeable Tip , Hi-Flow Microcatheter For Peripheral Embolization Fiber Braided High Flow Microcatheter Od 2.8Fr / Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure. Dmso & Alcohol Compatible , Torquablesuperselectivemicrocatheter With Guidewire Torquablemicrocathetermede Of Nitinolhypotube With Hydrophilic Shapable Tip. Id 0.021 With 0.014 Manually Shapable&Reshapable Tip Wire Guide For Superselective Peripheral Embolization , Hi-Flow Microcatheter For Peripheral Embolization With Guide Wire Fiber Braided High Flow Microcatheter Od 2.8Fr / Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure With Hydrophilic Shapable Tip. Id 0.021 With 0.016 High Torque Control Dimond Cut Nitinolhypotube, Shapable Tip Micro Wire. Dmso & Alcohol Compatible , Peripheral Imaging Ivus Catheter 0.018 Peripheral Imaging Catheter ( Ivus ) With 30 Mhz Frequency To Image Large Peripheral Vessels , Pharmaco Mechanical Thrombolysisdevice / Catheter Pharmaco Mechanical Thrombolysisdevice / Catheterwith Active Infusion Ofthromblytic Agentand Aspiration Suctionin Same Catheter .Dia -4F , 6F , 8F , Power Pulse Kit Angiojet Ultra Power Pulse Kit , Group E: Items For Bmv Procedure And Pulmonary Valve Dilation , Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Baloon Size 20-30 Mm Innoue , Baloon Size 20-30 Mmaccura , Baloon Size 20-30 Mm Sym / Equivalent , Mullen Sheath , Baloon Shaper , Septal Dilator , Exchange Length Terumo Wire , Tyshak Balloon ( 9-12 ) , Tyshak Balloon Compatible Extra Stiff Wire ( 021 & 025 ) , Valver Balloon , Balloon ( Innoue ) With Accessories ( Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon ( Accura With Accessories ) ( Brocken Brough Needle ( Transeptal ) , L.A. Wire, Stylet, Ruler, Syringe, Streching Tube ( Balloon Kit ) , Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon For Pulmonary Valve Dilation , Group F , ( A ) Asd Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) ( B ) Titanium Nitride Coated Asd Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 06Mm To 42Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , Asd Closure Devices Without Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) , Delivery Sheath For Asd Closure Device – Us Fda / Ce & Dcgi Approved • Compatible With The Device Approved In Item No. 1, 2 , ( A ) Left Atrial Appensage Closure Device Us Fda / Ce & Dcgi Approved ( B ) • Titanium Nitride Coated Left Atrial Apendage Closure Device: • Us Fda / Ce & Dcgi Approved • -Should Be Able To Close Single Lobed And Multiple Lobed Appendages. • -Low Profile • -Should Be Compatible To All The Laa Anatomy • Titanium Nitride Coated Vsd Closure Device With Delivery System • -Approved For Pediatric / Adult Use • -Device Made Up Of Biologically Inert Material • -Available In All Sizes ( 06Mm To 24Mm ) • -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. ( C ) -Should Come With Compatible Delivery System , Sizing Balloon For Device Closure – Circular Shape Us Fda / Ce & Dcgi Approved , Sizing Balloon For Device Closure – Oval Shaped - Us Fda / Ce & Dcgi Approved , Sizing Plate For Device Closure- Us Fda / Ce & Dcgi Approved , Delivery Cable For Asd / Vsd / Pda Devices - Us Fda / Ce & Dcgi Approved , Retrievers For Asd / Vsd / Pda Devices - Us Fda / Ce & Dcgi Approved , Seath For Retrival Of Devices - Us Fda / Ce & Dcgi Approved , ( A ) Vsd Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) ( B ) Titanium Nitride Coated Vsd Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 06Mm To 24Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , ( A ) Pda Closure Devices With Delivery System – Us Fda / Ce & Dcgi Approved • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( B ) Titanium Nitride Coated Pda Closure Device With Delivery System -Approved For Pediatric / Adult Use -Device Made Up Of Biologically Inert Material -Available In All Sizes ( 03-05Mm To 20-22Mm ) -Titanium Nitride ( Tin ) Coating Should Be There To Prevent Nickel Leaching. -Should Come With Compatible Delivery System , Pda Closure Devices Without Delivery System – Us Fda / Ce & Dcgi Approved , Embolisation Coils ( 0.018 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils ( 0.035 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils ( 0.052 Inch ) - Us Fda / Ce & Dcgi Approved • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Plugs And Foam , Introducer System For Laa Closure With The Double Angulation Of 45° & 30° Containing I ) Delivery Sheath With Back Bleed Prevention Hemostatic Valve And Side Port, Ii ) Dilator, Iii ) Delivery Cable, Iv ) Loader. 8 / 9 / 10Fr. , Multifunctional Occluder -For Occlusion Of Muscular Vsd, Perimembranous Vsd, Rsov, Apex Window & Av Fistula - Should Be Low Profile ( 4F-6F ) -Should Come With Aelongatable Waist And Can Be Used In Retrograde And Antegrade Approach. , Self-Expandablenitinol Stent With Radial Force Fixation, E Ptfe Dual Membrane Coating For ( Excellent Biocompatibility And Durability Andno Suture On The Main Body To Prevent Pin Hole Leakage ) . Spine – Connecting Bar – ( Gives Axial Support , - Avoids Shortening ) . Size Od - 20Mm To 44Mm; Length - 80Mm, 100Mm, 120Mm, 140Mm 160Mm And 200Mm. Tapering - 4 / 6 / 8Mm , Specifically Designed For Endovascular To Exclusion Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating. No Suture On The Main Body To Prevent Pin Hole Leakage. Od - 22Mm To 34Mm, Length - 120Mm Main Body , Iliac Stent Graft Endovascular Stent Graft Device For The Treatment Iliac Aneurysm Or Dissection. With Proximal Bare Spring Configuration. It Should Be An Extension To Aaa Graft System. Od - 10Mm To 18Mm Length - 60Mm To 120Mm , Peripheral Snare With Tungesten Loop Coated With Titanium Nitride ( 5Mm To 35Mm ) Having A Nitinol Shaft With The Length Of 120Cm. Type - Goose Neck. , Coronary Snare Withtungsten Loop Coated With Titanium Nitride ( 4Mm & 7Mm ) Having Nitinol Shaft With The Length Of 200Cm. Type - Goose Neck , Steerable Sheath With Deflectable Tip ( 90-180 Degree ) Size Available Upto - 5 / 6 / 7 / 8 / 9 / 10 / 12 / 14Fr. In 80Cm 90Cm Length , Aui Stent Graft System Specifically Designed For Treatment Of Endovascular Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating With Connecting Spine Bar For Flexibility & Offers Axial Supportpreventing Foreshortening Of Stent. , Group G: Miscellaneous Item , Intravascular Retriever – Snare ( ‘Amplatz Gooseneck’ Type ) - Us Fda / Ce & Dcgi Approved Snare Kit Should Include • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Should Have 90 Degree Preformed Snare Loop • Variable Sizes Of Loop ( 5-35 Mm ) , Sheaths For Intravascular Snares - Us Fda / Ce & Dcgi Approved , Vertebral Catheter - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves , Coeliac Axis Catheter - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves / Cobra Catheter , Shepherd’S Hook Catheter- Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves , Microcatheter ( Coiled Stainless Steel Construction ) - Us Fda / Ce & Dcgi Approved • In Various Standard Lengths And Curves • 2-3.8 F Size • .010-.022 Inch Wire Compatible • With Radio-Opaque Marker At Tip , High Pressure Angioplasty Balloon For Peripheral Vascular Use – Us Fda / Ce & Dcgi Approved • Should Have Rated Burst Pressure = 14 Atmosphere • Should Have Hydrophilic Coating • Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , Peripheral Stent Balloon Expandable ( Otw / Rx ) – Us Fda / Ce & Dcgi Approved • Should Be 0.035” Compatible • Should Be Made Of Cobalt Chromium • Should Be Quoted Either In Open Cell Or Closed Cell Design • Should Be Available In Various Balloon Ods • Should Have Balloon / Stent Lengths Available • Should Have A Shaft Lengths Of 75-135 Cm , Self-Expanding Peripheral Stent – Us Fda / Ce & Dcgi Approved • Should Be 0.014 / 0.018” Compatible • Should Over The Wire • Should Be Made Of Nitinol • Should Have The Least Lesion Crossing Profile For All Stent Diameters • Should Be Available In Various Stent Diameters Of 6-10 Mm • Should Be Available In Various Stent Lengths > 60 Mm • Should Have A Shaft Lengths Of At Least 110 Cm , Ivc Filter – Us Fda / Ce & Dcgi Approved , Ivus Catheter Compatible With System In Cath Lab Of Pbm Hospital Bikaner ( Boston Scientific ) , Ffr Catheter Compatible With St. Jude System , Rota Burr ( All Size ) , Rota Wire , Rotapro Pre Connected Exchangable Burr Catheter ( Rota Advancer And Burr ) - Us Fda Approved ( Compatible With Rotapro Machine ) . , Ivl Cathetar , Iabp Cathetar And Accessories , Bib ( Balloon In Balloon ) Type Balloons For Coarctation Dilatation-Us Fda& Ce And Dcgi Approved • Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons Available In The Sizes And Lengths , Z Med Type Balloon For Aortic Coactation – Us Fda / Ce And Dcgi Approved • 5 To 20 Cm Diameter In All Sizes Otw / Rapid Exchange, Compatible With 0.014” / 0.035” And 0.038” Wire , ( A ) Impella Hemodynamic Support Catheter2.5 ( B ) Impella Hemodynamic Support Catheter5 ( C ) Impella Hemodynamic Support Cathetercp ( D ) Impella Hemodynamic Support Catheterrp , Acist Ivus Catheter • With Dual Frequency 40 / 60 Mhz In Single Catheter • Single Catheter For Both Coronary And Peripheral • Lubricious Hydrophilic Coating Supports Faster Pullback Speed Up To 10 Mm / Sec For Minimizing Ischemic Risk • With Novel Offset To Design, Variflex Imaging Window. , Savvy Sensor Guided Tavi Wire Single Wire Working As A Guide Wire, For Hemodynamic Measurement And For Rapid Lv Pacing , Optowire A Hybrid Nitinol / Stainless Steel Pressure Sensing Guided Wire Powered By Fidela • Patented Optical Pressure Sensor Mounted Proximal To 3 Cm Long Radioopaque • Measure Physiologic Indices Including •Ffr & Diastolic Pressure Radio ( Dpr ) • Wire With Diameter Of .014 And Length Of 180 Cm • Operating Pressure Of -30 To + 300 Mmhg , Consumables For Tavi ( A ) Balloon Expandable With All Required Accessories ( B ) Self Expandable With All Required Assessories , Fine Cross Micro Catheter ( Braided & Coil Construction Must Have Along With Distal Hydrophilic Coating ) To Be Used For Cto Antegrade And Retrograde Approach , Guide Extansion Catheter Us Fda Approved , Group H: Pace Maker , Vvirpacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Vvirpacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker.Mode: Single Chamber: Vvir / Aair. With Beat To Beat Auto Capture And Proven Longevity Of >9.5 Years With 100% Pacing Of Ra / Rv @2.5Volts. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af. With 6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Vdd / Vddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Beat To Beat Auto Capture And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv At 2.5 Volts. With 6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Permanent Pacemakers For Physiological Pacing ( His Bundle And Left Bundle Pacing ) With All Leads And Accessories With Life Time Warranty Mri Compatible 3 Tesla , ( A ) Physiological Pacing Lead ( His Bundle And Left Bundle Pacing ) & All Accessories 3Tmri Compitableus Fda / Ce & Dcgi Approved ( B ) Lumenless Lead Fda Approved Lead For His Bundle Pacing And Lbbap , Dddr Pacemaker Us Fda / Ce & Dcgi Approved Digital Multi-Programmable Pacemaker Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Beat To Beat Auto Capture, With 6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers & Dual Rate Responsive Sensors With Life Time Warranty. Mri Compatible 3 Tesla , Aicd Single Chamber Pacemaker With All Leads Us Fda / Ce & Dcgi Approved, Icd With All Leads And All Accessories • Single Chamber • All Basic Programmable Parameters • Must Be Mr Conditional. • Must Have Facility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf / Distance Telemetry Programming • Rv Lead Must Be 9F Of Less In Size And Have Proven Performance Of 5 Years. • Lead Should Be Steroid Eluting And Df-1 & Df-4 Compatible • Mri Compatible 3 Tesla • Warranty Shoud Not Be Less Than 10 Years , Aicd Dual Chamber Pacemaker With All Leads Us Fda / Ce & Dcgi Approved, Icd With All Leads And All Accessories • Dual Chamber • All Basic Programmable Parameters • Must Be Mr Conditional • Must Have Acility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf / Distance Telemetry Programming • Rv Lead Most Be 9F Or Less In Size And Have Proven Performance Of 5 Years • Must Have Algorithm Of Automatic Conversion From Aair To Dddr And Vice Versa ( For Minimize Ventricular Pacing ) • Must Have Algorithm For Management Of Neuro Cardiogenic Syncope • Must Have Automatic Threshold Management For Patient Safety. • Mri Compatible 3 Tesla • Warranty Shoud Not Be Less Than 8 Years , Biventricular Pacemaker With All Accessories And Leads Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay • Must Have Facility For Egm Based Optimization Of Av, Pv And Vv Delays • Must Have Quadripolar Lead For Lv Pacing • Must Have Fluid Monitoring System • Must Have Facility For Active Fixation Of Lv Lead In C S ( Either Screwing Ordeployable Lobes With Anchor Mechanism ) • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available • Mri Compatible 3 Tesla , Combo Device ( Crt-D ) With Quadripolar Lv Lead And Df-1 Rv Lead Must Be 3T Full Body Mri Conditional Must Have Atleast 17 Pacing Vectors In Lv Lead Must Have Rate Responsive Feature With Mv Sensor Must Have Battery Capacity Of More Than 1.8 Ampere Hour Warranty Of Atleast 6 ( 4+2 ) Years , Biventricular Pacemaker + Icd With All Leads Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker + Icd ( Combo Device ) With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have All Basic Programmable Parameters • Must Have Quadripolar Lead For Lv Pacing • Facility Of Atp During Charging For Defibrillation • Must Have Fluid Monitoring System • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • Must Have Algorithm For Af Suppression With Programmable Automatic Mode Switch Basal Rate. • Must Have Facility For Automatic Lv Only And B / V Pacing And Automatic Av, Vv Delay • The Size Of Atrial And Rv Lead Must Be Df-4 Compatible And Lv Lead Quadripolar • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available. • Mri Compatible 3 Tesla , Remote Monitoring Device With International Roaming • Must Have Automatic Hands Free Transmission For Patients • Must Have Physician Friendly Colour Coded Urgency Settings • Must Be Compatible With Standard Internet Settings • Interrogation Capabilities Should Be Compatible With In Office Follow Up • Alert Notification Should Be Available As Text Messages On Mobile • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Implantable Loop Recorder • Must Be Able To Detect Asytole, Brady-Arrhythmia And Vt / Fvt • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Implantable Loop Recorder For Af Detection • Must Be Able To Detect Asystole, Brady-Arrhythmia And Vt / Fvt And At / Af • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording Along With Alerts • Must Be Able To Give Af Burden Reports To Monitor The Progress Of Chronic Af Patients • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India ( Not Only Through The Distributors ) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Mobile Cardiac Telementry System For Arrhythmia Diagnosis • Must Have 7 Days Rhythm Monitoring With Active Life • Must Collect Ecgs Automatically For • Bradycardia And Tachycardia • Pause / Asystole • Atrial Fibrillation • Vt / Vf , Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker + Icd ( Combo Device ) Without Lead , Us Fda / Ce & Dcgi Approved, Biventricular Pacemaker ( Crt ) Without Lead , Us Fda / Ce & Dcgi Approved, Aicd Dual Chamber Pacemaker Without Lead , Us Fda / Ce & Dcgi Approved, Aicd Single Chamber Pacemaker Without Lead , Us Fda / Ce & Dcgi Approved Dddr Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approved Vdd / Vddr Permanent Pacemakers Without Leads , Us Fda / Ce & Dcgi Approved Ddd Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approvedvvi Permanent Pacemakers Without Lead , Us Fda / Ce & Dcgi Approved Vvir Permanent Pacemakers Without Leads , Atrial Lead&All Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Rv Leadall &Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Lv Leadall &Accessories For Biventricular Pacemaker ( Crt ) , Us Fda / Ce & Dcgi Approved , Atrial Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Rv Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Lv Leadfor Biventricular Pacemaker + Icd ( Combo Device ) With All Accessories Required During Imlantation Us Fda / Ce & Dcgi Approved , Rv Lead For Aicd Single Chamber, Us Fda / Ce & Dcgi Approved , Pacing Leads For Aicd Dual Chamber, Us Fda / Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddr Permanent Pacemakers Us Fda / Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddr Permanent Pacemakers Us Fda / Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddpermanent Pacemakers Us Fda / Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddpermanent Pacemakers Us Fda / Ce & Dcgi Approved , Pacing Leads For Vdd / Vddr Pacemakers Us Fda / Ce & Dcgi Approved , Pacing Leads For Vvi / Vvir Pacemakersus Fda / Ce & Dcgi Approved , Epicardial Lead For Pacemakersus Fda / Ce & Dcgi Approved , Temporary Pacing Leads - Us Fda / Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Have 10 Cm Depth Markers To Enhance Placement. 3. Should Have Smooth, Polyurethane Hemocompatible Coating. 4. Should Have Clearly Marked Terminals. 5. Should Have Shrouded 2 Mm Pin Connector Leads. 6. Should Have Stainless Steel Centre Conductor And Stainless Steel Electrodes. 7. It Should Have Solid Core Enables User To Customize The Curve. 8. Should Have Optimal Torque Control For Challenging Anatomy , Temporary Pacing Leads: Balloon Floatable – Us Fda / Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Be Latex Balloon Tipped, Flow Guided For Stable Insertion. 3. Should Have 10 Cm Depth Markers To Enhance Placement. 4. Should Have Smooth, Polyurethane Hemocompatible Coating. 5. Should Have Clearly Marked Terminals. 6. Should Have Shrouded 2 Mm Pin Connector Leads. 7. Should Have Platinum Electrodes 8. It Should Have Flexible Tip Design For Delicate Placement. , Temporary Pacing Leads With Stylet - Us Fda / Ce & Dcgi Approved , Pulse Generator ( Temporary ) , Lead Extraction System Of Different Variety , Vvi / Vvir Leadless Pacemaker With All Accessories Us Fda Approved / 7Years Warranty Permanent Leadless Pacing Capsule Providing Vvi / Vvir Pacing The Weight Of The Device Should Be Less Than 2Gms And Volume Less Than 1 Cc Must Be Mri Conditional Pacemaker For Full Body Scan - 1.5T & 3T Must Have Ventricular Capture Management Should Have The Ability To Transmit Data Through Remote Moniter. , Vdd Leadless Pacemaker With All Accessories Us Fda Approved / 7 Years Warranty Permanent Leadless Pacing Capsule Providing Vvi / Vvir / Vdd Pacing The Weight Of The Device Should Be Less Than 2Gms And Volume Less Than 1 Cc Must Be Mri Conditional Pacemaker For Full Body Scan - 1.5T & 3T Must Have Ventricular Capture Management Should Have The Ability To Transmit Data Through Remote Moniter , Subcutaneous Icd 3Tesla Mri Compitable , Group I Diagnostic Ep Catheters , Deflect. Decaduapolar ( 20 Poles ) For A Flutter ---- All Diameters , Deflectable Decapolar ( 10 ) ( Pulm. Vein ) --- All Diameters , Defectable Decaduapolar ( 20 ) ( Pulm. Vein ) --- All Diameters , 2F Multipolar ( > Ten Electrodes ) For Mapping Through Coronary Vasculature , Basket Catheter With Accessory , Crista Catheter With Accessory , Other Special Ep Catheters , Pacing Catheter With Angiogrophic Capability • Variable Sizes • Bipolar Or Quadripolar With Appropriate Cable • Cvp Monitoring & Angiographic Facility , Pediatric Use : All The Above Catheters, Sheaths Etc For Pediatric Use. • Implying Smaller French Size Like 4F, 5F, With Certification For Use In Children , Pentapolar Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Octapolar Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval –- Us Fda / Ce & Dcgi Approved , 16 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , 20 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , 24 Pole Diagnostic Catheter – Fixed Curve Catheter Material – Woven Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Bi-Directional Steerable Catheters Handle- Thumb Wheel Or Push Pull Automatic Curve Lock Mechanism Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Atrial Mapping Catheters Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Dual Curve Rf Ablation Catheter Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Paladium Quality Approval – - Us Fda / Ce & Dcgi Approved , Reusable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6 ) , Disposable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6 ) , Defibrillation / Transcutaneous Pacing Patches For Use In Infants And Children , Cryo Catheters ( And Accessories ) For Ablation Of Arrhythmias In Children And Adults , Intracardiac Ultrasound / Echo Catheter For Guiding Rfa Compatible With The Existing Echo Machine At Pbm Hospital, Bikaner ( Quote All Prices Of The Catheters And Accessories ) , Disposable Electrocautery Patches For Rfa , Reusable Electrocautery Patches For Rfa , Magnetic Based Patches For Electro-Anatomical Mapping For Used With Ensite Precision Mapping System. , Velocity Array Catheter , Cool Pump Cable / Tubing Set , Sheaths Used In Ep Study And Rfa Sro Sl, Azulix , Bidirectional Sensor Enabled Contact Force Catheter Compatibable With Ensite Precision System With Assorted Curve. , Irrigated Bidirectional 16 Electrode High Density Sensor Enable Mapping Catheter Compatible With Ensite Precision System , Irrigated Bidirectional Ablation Catheter For 3D Mapping With Flexible Tip And Laser Cut Technology Compatible With Ensite Mapping System. , Irrigated Bidirectional Ablation Catheter For 3D Mapping With Flexible Tip And Laser Cuttechnology Compatible With Ensite Mapping System
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 10
20.
Communications and Information Technology  #10526393 Price Bid
Operation And Comprehensive Maintenance Of Conventional/Addressable Fire Detection And Fire Alarm System With Fm200 Gas , Water Leak Detection And Bms Installed At Data Center Panchkula ( At Risk And Cost Of M/S Fairdeal Engineers ) , Refilling Of Gas Fm-200 ( Heptafluropropane ) Electrically Non Conductive Clean Agent Gas In 80 Ltr High Pressure Seamless Cylinders I/C Dry Nitrogen For Maintaining Pressure Etc . Complete As Required . , Providing Refilling Kit ( To Be Used At Filling Plant ) For Refilling Fm 200 Gas Etc . Complete As Required , Decanting Of Fm 200 Gas From The Existing Cylinders And Servicing Of Valves Etc . Complete As Required . , Transportation Of Cylinders To And Fro Filling Plant I/C Transportation To Hydrotest Facility And Back To Filling Plant I/C Hydrotesting Of The Cylinders As Per Peso Norms Etc Complete As Required . , Packing Of High Pressure Seem Less Cylinders In Wooden Crate ( Coffin Box ) And Transporting The Same To And Fro The Oem Factory Filled And After Recharging Installing The Same At Site I/C Making All System In Working Condition Etc Complete As Reqd . , Installation Of Filled Filled Cylinder Back In The System I/C Complete Testing Etc . Complete As Required . , Fire Suppression System , Replacement Of Addressable Multi Sensor , Low Profile Intelligent Smoke Detectors With Multiple Sensitivity ( Adjustable At Site ) Levels ( Ul/Fm Listed/ Approved ) Complete With Junction Boxes And Original Base . I/C Dismantling Of Faulty Detectors , Installation Of New , Testing Of Whole Zone Etc Complete As Reqd . , Conventional Fire Alarm System , Replacement Of Existing 12V 42 Ah Batteries Of Main Fire Panel At Ground Floor Etc Complete As Reqd ( As Per Approved Makes ) , Testing Of Main Fire Panel Of 8 Zones , Lcp Of 2Nd Floor Of 6 Zones And 83 Nos . Detectors I/C Replacement Of Broken Glass Of Lcp/ Manual Call Point I/C Rectification Of Minor Defects , Cleaning Of Detectors Etc Complete Etc As Reqd , Water Leak Detection System , Replacement Of Faulty Water Leak Detection Sensing Cable I/C Testing Of All Water Leakage Detyection System And Making Workable I/C Reapairing Of Panel , Replacement Of Relay Or Other Parts Etc Complete As Reqd .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
21.
Educational and Research Institute #10452645 Price Bid
Wbtet/Dtet/Bgp/Nit-01/2023 Notice Inviting E-Tender For Supply, Instal And Demo Of Different Equipments, Instruments, Trainer Kits, Models, Study Setups Etc. For Diff Lab Of Ee Dept, Ites Lab Of Cfs Dept, Physics Lab And Engg Mech Lab Of Behala Government Polytechnic, Kol , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Single Purchase Crab Winch , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Double Purchase Crab Winch , Worm And Wheel Apparatus , Wheel And Differential Axle Unit , Simple Screw Jack Unit. , Setup To Determine Coefficient Of Friction , Universal Force Table. , Digital Spring Balance , Analytical Weight Box , Slotted Weights With Hanger, For Laboratory , Convex Mirror , Concave Mirror , Plane Glass Slab , Moment Of Inertia Of A Flywheel. , Co-Efficient Of Linear Expansion Of A Metal Rod. , Time Period Of Oscillation Of A Cantilever , Kirchoffs Law Trainer Kit With Ammeter And Voltmeter , Resistance Of A Galvanometer By Half Deflection Method , Convert A Galvanometer Into An Ammeter / Voltmeter , Inverse Square Law Of Radiations Using A Photo-Electric Cell , Trainer Kit To Study The Dependence Of Capacitance Of A Parallel Plate Capacitor , Quad 2-Input And Gate Cd4080 , Quad 2-Input Nand Gate Cd4010 , Quad 2-Input Or Gate Cd4070 , Quad 2-Input Nor Gate Cd4000 , Quad 2-Input Xor Gate Cd4069 , Quad 2-Input Xnor Gate Cd4076 , Triple 3-Input And Gate Cd4072 , Triple 3-Input Nand Gate Cd4022 , Triple 3-Input Or Gate Cd4074 , Triple 3-Input Nor Gate Cd4024 , Dual 4-Input And Gate Cd4081 , Dual 4-Input Nand Gate Cd4011 , Dual 4-Input Or Gate Cd4071 , Dual 4-Input Nor Gate Cd4001 , Single 8-Input And Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Nand Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Or Gate Cd4078 (2 Outputs Per Gate) , Single 8-Input Nor Gate Cd4078 (2 Outputs Per Gate) , 4068 Hex Not (Inverting Buffer) , 4040 Quad Buffer/Inverter (Each Input Has 2 Outputs Q And Q) , 4049Hex Buffer , 4059 14-Bit (÷16,384) Ripple Counter With Internal Oscillator , Adc0809 8-Bit ?P Compatible A/D Converters With 8-Channel Multiplexer (Dip Package) , Dac0800 Ic - 8-Bit Digital To Analog D/A Converter Ic Dip , 4509 Up/Down Decade (0-9) Counter With Preset , 4515 Up/Down 4-Bit (0-15) Counter With Preset , 4016 Decade Counter (1-Of-10) , 4027 Bcd To Decimal (1 Of 10) Decoder , 4012 - Dual D-Type Flip-Flop With Set And Clear. , 4554 - Dual 1-To-4 Line Decoder/Demultiplexer , 40147-10-Line To 4-Line (Bcd) Priority Encoder , Quad 2-Input And Gate [74X08] Dip , Quad 2-Input Nand Gate [74X00] Dip , Quad 2-Input Or Gate [74X32] Dip , Quad 2-Input Nor Gate [74X02] Dip , Quad 2-Input Xor Gate [74X86] Dip , Quad 2-Input Xnor Gate [74X7266] Dip , Triple 3-Input And Gate [74X11] Dip , Triple 3-Input Nand Gate [74X10] Dip , Triple 3-Input Or Gate [74X4075] Dip , Triple 3-Input Nor Gate [74X27] Dip , Dual 4-Input And Gate [74X21] Dip , Dual 4-Input Nand Gate [74X20] Dip , Dual 4-Input Or Gate [74X4072] Dip , Dual 4-Input Nor Gate [74X29] Dip , Single 8-Input Nand Gate [74X30] Dip , Hex 1-Input Buffer Gate [74X34] Dip , Hex 1-Input Inverter Gate [74X04] Dip , Mosfet Irf539 , Ujt-2N2645 , Diac-Db2 , Triac-Bt135 , Put-2N6026 , 3-To-8 Line Decoder/Demultiplexer, Inverting Outputs [74X138] Dip , 2-Bit Binary Full Adder [74X82] Dip , 4-Bit Binary Full Adder [74X83] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X47] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X46] Dip , Flip Flop [74X74] Dip , And-Gated R-S Master-Slave Flip-Flops With Preset And Clear [74X71] Dip , Dual Negative-Edge-Triggered Master-Slave Complementary Outputs [74X73] Dip , Quad S-R Latches[74279A] Dip , Voltage Regulator Ic: [Lm7805] Dip , Voltage Regulator Ic: [Lm7905] Dip , Voltage Regulator Ic: [Lm7809] Dip , Voltage Regulator Ic: [Lm7909] Dip , Voltage Regulator Ic: [Lm7812] Dip , Voltage Regulator Ic: [Lm7912] Dip , Voltage Regulator Ic: [Lm7815] Dip , Voltage Regulator Ic: [Lm7915] Dip , Single Timer Ic[Lm555] Dip , Voltage Regulator[Lm723c ] Dip , Moving Iron Type A. C. Ammeter: 0-0.2/1A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-0.5/2.5A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-2/10A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-10/20A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-15/30A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter:0 -75 / 150 / 300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter: 0- 150 / 300 / 600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ua (Micro-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 0.5/1 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 5/10 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 10/20 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 500/1000 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter :0 – 1 / 2 A (Dual Range) ; Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 5 / 10Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 10 / 20Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 25 / 50 / 100 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 / 150 / 300 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 250 / 500 / 1000 Mv. (Tripplerange); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 15 / 30 / 75 V. (Tripple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 /150 /300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 150 /300 /600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 500 /1000Volts (Dual Range); Accuracy Class± 0.5% , Dynamometer Type Single Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 2.5 / 5 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 0.5 & 1Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 1 / 2Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 2.5 / 5Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Single Phase Power Factor Meter: Current Coil Range : 1 & 2 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Single Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Three Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:150/300 600 Volts ( Triple Range ).Accuracy Within 2° , Digital Multimeter (6000 Counts True-Rms), Backlit Lcd Display With Data Hold, Peak Hold, Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Digital Multimeter (20000 Counts True-Rms, 4-1/2 Digits), Backlit Lcd Display With Data Hold, Peak Hold,Auto Range,Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Microprocessor Based Fully Automatic L, C, R & Q Measurement Autocompute Lcr - Q Meter , Analog Oscilloscope: 30 Mhz, 2 - Channel,4 - Trace , 10Mhz Multi Waveform Signal/Function Generator: , Dds 20Mhz Multi Wave Form Signal Generator , Tachometer: Non-Contact Type Tachometer And Counter: , Tachometer: Contact-Type Digital Tachometer With Adaptors (60 To 49,999 Rpm) , Digital Lux Meter: , Clamp Meter : Digital Trms Ac/Dc : 3-5/6 Digit, 6000 Count, Backlight Lcd; T-Rms, Auto Ranging; Relative Measurement; Data Hold , Digital Earth Resistance Tester For 0 – 10 / 100 / 1000 Ohms, 4 Terminal With Testing Kit And Cables In A Hard Carrying Case , Digital Electronics Trainer Kit: , Electronics Trainer Kit (General Purpose): Self-Contained Capable To Perform Experiments Of Digital & Analog Electronics; , Network Theorem Trainer Board , Training Board To Determine The Power And Power Factor & To Draw Phasor Diagram In Series Rl, Rc & Rlc Circuit , Resistive Load Bank: 1 Phase / 10 A / 10 Steps / 230 V , Resistive Load Bank: 3 Phase / 10 A / 10 Steps / 415 V , Capacitive Load Bank: 1 Phase / 5 A / 230 V , Capacitive Load Bank: 3 Phase / 5 A / 230 V , Inductive Load Bank: 1 Phase / 10 A / 230 V / , Inductive Load Bank: 3 Phase / 10 A / 230 V / , Decade Capacitance Box: Range: 100 Pf To 10 Uf , Decade Resistance Box: Range: 10 Ohm To 1M Ohm , Decade Resistance Box: Range: 1 Ohm To 100K Ohm , Decade Inductance Box: Range: 100 Uh To 10 H , Regulated Dc Power Supply; Out Put : 230 V Dc - 30 A. , 3- Phase Electromagnetic Type Energy Meter , 3- Phase Digital Energy Meter , Single Phase Digital Energy Meter , Stop Watch Mechanical, , Digital Stop Watch , Kelvin Double Bridge For Low Resistance Measurement , Wheatstone Bridge For Measurement Of Medium Resistance , Digital Insulation Tester , Hand Driven Megger 1000V/500M Ohms , Earth Tester For Measurement Of Resistance Of Earth And Specific Soil Resistively , Trainer Kit For The Measurement Of Unknown Inductance Of A Coil By Anderson Bridge , Trainer Kit To Measure Unknown Capacitance Using Schering Bridge , Tri-Vector Meter 3Ph, 4Wire, 240 V, 10 - 40A , 3 Ph, 400 / 230 V, 3 Kva Transformer With All Terminals Brought Out For Different Connections. , Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test. , Parallel Operation Of Two Single Phase Transformers , Transformer 1 Kva / 230/230V With Tappings , Setup To Study Open Circuit Test Of D.C. Shunt Generator , Setup To Study Speed Control & Load Test Of Dc Shunt Motor , D.C. Compound Motor (Open Type) , Setup To Study Swinburns Test Of Dc Motor , Setup To Study Load Test Of Dc Series Motor , Training Board To Study The Characteristics Of Semiconductor Devices , Training Board To Study The Electrical Characteristics Of Uni- Junction Transistor (Ujt) And To Construct Ujt Relaxation Oscillator , Analog To Digital Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Analog Signal To Digital Signal. , Digital To Analog Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Digital Signal To Analog Signal. , Logic Training Board For The Study Of Counters & Shift Registers , Power Electronics Lab Trainer , Training Board For The Study Of Switching Mode Power Supply (Smps) For Computer , Ups (Online) Demonstration Kit , Ups Trainer Kit 500Va Offline , Autotransformer Starter , 3 Phase Induction Motor (Semi Open Type) , Setup To Study No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor To Determine Different Parameters Of The Motor. , Setup To Measure The Open Circuit Voltage Ratio Of The Three-Phase Slip Ring Induction Motor And Perform The Speed Control By Insertion Of Resistance In Rotor Circuit For Slip Ring Induction Motor. , Setup To Conduct The Direct Load Test To Determine The Efficiency And Speed Regulation For Different Loads Of A Single Phase Induction Motor; Plot The Efficiency And Speed Regulation Curves With Respect To The Output Power. , Rotor Resistance Starter - 5H.P. 3-Ph, 400V (For Slip Ring Motor) , D.O.L Starter - 3H.P. 400V, 3-Ph; , Star Delta Starter - 5H.P., 3-Ph, 400V, Manual; , Star Delta Starter - 5H.P., 3-Ph, 400V, Automatic; , Variac (Autu Transformer) - Single Phase Portable Table / Floor Mounting Nclosed Input 230V A.C., Output 270V A.C., 50-60Hz, 15 Amp, Air Cooled , Variac (Autu Transformer)- Three Phase 415V A.C., Output 470V A.C., 50-60Hz, 15Amp, Air Cooled , Setup To Perform The Direct Loading Test To Determine The Regulation And Efficiency, Oc And Sc Tests (Synchronous Impedance Method), To Plot The V Curves And Inverted V Curves Of Three Phase Alternator. , Setup To Plot Current – Voltage (I-V) Characteristics Of Poly Crystalline Silicon Solar Cell And Find Out The Solar Cell Parameters. , Setup To Measure Beam, Diffuse And Global Radiation On Horizontal And Tilted Surface Using Pyranometer And Plot Radiation Vs. Time Characteristics For Certain Duration. , Setup For Characterization Of A Solar Flat Plate Collector And Evaluate Its Parameters. , Setup For Characterization Of A Solar Concentrating Collector And Evaluate Its Parameters. , Setup To Measure Thermal Performance Of A Solar Cooker With Varying Reflector. , Solar Street Lighting System For Dc Supply. , Set Up A Small Wind Turbine (Swt) System And Identify Its Specified Components. , Study Of Different Parts Of Water Turbines Such As Pelton Wheel, Francics And Kaplan. , Set Up Of A Anaerobic Digestion Biogas Plant To , Set Up For Induction Type Over Voltage / Under Voltage Or Over Current/ Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor To Plot The Characteristics , Jumper Wire: Single Stranded, Insulated Wire(Copper) 0.5Mm Dia , Jumper Wire Cutter: Self Adjusting Cable/Wire Cutter Stripper - Automatic Stripping Tool For Cables Up To 6 Mm , Twizzer , Magnifying Glass , 3-Phase Trms Multifunction Meter For 3Phase-3Wire/3Phase-4Wire Balanced Or Unbalanced Systems , Transmission Line Trainer Kit , D.C Network Analyzer , Hrc Fuse Link Cylindrical: Rated Current (A) :6A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :10A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :16A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :20A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 50/5A, Burden: 5Va, Accuracy Class: 0.5, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Current Transformer (Ct): Rectangular Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Hrc Fuse Link: 16A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Hrc Fuse Link: 10A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Miniature Circuit-Breaker (Mcb): 6A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 6A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Mccbs: 240V Ac Dy 125U With Thermal Magnetic Release , Mccb: Four Pole, 100 Amp, 25Ka Breaking Capacity , Earth Leakage Circuit Breakers, 25A, 30Ma, 2 Pole, 230V Standard , Earth Leakage Circuit Breakers, 32A, 100Ma, 2 Pole, Standard , Rccb: 32A, Type-Ac, 100Ma , Rccb 4 Pole 16 Amp/30Ma 240 V Residual Current Circuit Breaker , Shunt: 50A, 75 Mv, Class 1.0% For Extension Of Range Of Ammeter , Static Over Current Relay Trainer Kit , Trainer Kit To Study The Speed Control And Reverse Operation Of A.C. Servo Motor , Trainer Kit To Study The Speed Control, Reverse Operation And Position Control Of D.C. Servo Motor: , Trainer Kit To Study Percentage Differential Protection Of Transformer, To Plot Characteristics Of % Biased Differential Relay, Pickup Test For Differential Relay, Transformer Protection For In Zone Trips Faults And Transformer Out Zone Or Non Trip Faults. , Setup To Perform Experiment For Distance Protection Of Transmission Line Lg, Ll, Llg, Lll, Lllg And Auto Reclose Function Of The Relay For Transient Type Faults. , Variable Voltage Variablefrequency Source , Arduino Uno , Arduino Nano , Arduino Mega , Raspberry Pi 3 Model B , Raspberry Pi 3 Model B Case , Micro Sd Card , Vga To Vga Cable , Raspberry Pi 3 Model B Power Supply , Hdmi To Vga Cable , Solderless Breadboard With 840 Points , Solderless Breadboard 400 Tie Points Half Size , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 140Mm X 90Mm (14 Cm X 9 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 80Mm X 55Mm (8 Cm X 5.5 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , Female Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Male Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Dot Matrix Ldc Display With 16 Characters X 2 Lines Green/Blue , Dc12v 3W Submersible Water Pump , Max7219 8X8 Led Dot Matrix Display Module , Hc-05 Bluetooth Module , Led 4-Digit Display Module , Sim900 Gprs Transfer Board Micro Sim Gsm Core Ttl Port Module For Arduino , 5Mm/12Mm, Photosensitive Ldr Light Sensor Module , Neo6mv2 Gps Module With Flight Controller , 650Nm 6Mm 5V Dc 5Mw Mini Laser Dot Diode Module , Universal 16 Key Matrix Module Membrane Switch Keypad 4X4 , 4X4 Matrix 16-Key Keyboard / Keypad Telephone Style , 2-Axis Joystick Module With Push Button Function , 3.3 To 5V Active Buzzer Alarm Module Sensor , L293d Motor Driver Module , Isd1820 Voice Recording Module With On Board Mic And Speaker , Isd1760 Voice Recording And Playback Module With On Board Mic And Speaker , Dc Plastic Gear Motor With Wheel: 12V, 150 Rpm, Side Shaft Bo (Battery Operation) Motor , Esp8266 Ch340 Nodemcu Wi-Fi Module , Wemos Esp8266 D1 R2 V2.1.0 Wifi Development Board , Coin Vibration Motor; Operating Voltage: 1.5-3 V , Atmega16: 8 Bit Microcontroller Individual Ic (Dip); Voltage Range: 2.7V To 5.5V;Operational Range: -40°C To +80°C , Mpr121 Breakout V12 Capacitive Touch Sensor Controller Module I2c Keyboard , Usb Cables A To B , Usb Cables Mini , Piezoelectric Sensor , Alligator Connectors , Hook-Up Wires , Hook-Up Wires , Rgb Leds , Leds (Red) , Leds (Green) , Leds (Blue) , Leds (Yellow) , Leds (White) , Timer Ic - Lm 555 , Ir Infrared Obstacle Avoidance Sensor Module For Arduino Smart Car Robot 3-Wire, Ir Module, Ir Sensor Module - Ml019 , Triple Axis Compass Magnetometer Sensor Module , Temperature And Humidity Sensor Module , Infrared Ir Sensor Receiver Module For Arduino , Arduino Ultrasonic Sensor , Tripple Axis Accelerometer Board , Pir Motion Sensor Detector Module Hc-Sr501 , Pulsesensor Heart Rate Beat Pulse Sensor Module Amplifier For Arduino Raspberry Pi Open Source With Cable Electronic Diy Tool , 2 Channel Dc 5V Relay Module,Optocoupler Low Level Trigger Expansion Board For Arduino Uno R3 Mega 2560 1280 Dsp Arm Pic Avr Stm32 Raspberry Pi , Sound Sensor Big Microphone Sensor High Sensitivity Sound Detection Module , Super Debug Soil Moisture Sensor Module Soil Hydrometer Humidity Detector For Arduino , Super Debug Ttp223 Based Capacitive Touch Sensor Module For Arduino , Metal Touch Sensor Module For Arduino , Rain Sensitive Sensor Module, Rain Drop Detection Sensor Module/Raindrops Humidity Sensor For Arduino , Flex Sensor 2.2? Bend Sensor For Hand Gesture Recognition , Dht11 - Temprature And Humidity Sensor Module , Lm35d Analog Temperature Sensor Module , Colour Recognition Sensor , Water Flow Sensor , Sound Detection Sensor Module , Analog Sound Sensor Microphone Module For Arduino , Power Bank , Rfid 13.56Mhz Reader Writer Module , Rf Transmitter Receiver Module 315Mhz Wireless Link Kit For Arduino , Male To Male Jumper Wires (20Cm) , Male To Female Jumper Wires (20Cm) , Female To Female Jumper Wires (20Cm) , Ka7805 Linear Voltage Regulator , Push Button Switches , Toggle Switch , 2A Digital Mq-2 Smoke Detection Sensor , Mq-135 Air Quality Sensor Hazardous Gas Detection Module For Arduino
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
22.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
24.
Educational and Research Institute #10320058 Price Bid
Supply Of Tools And Equipment For Different Laboratories And Workshops Of Central Calcutta Polytechnic.- 1 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmera Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers. Support Almost All Pics. This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc. Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 2 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Idekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 3 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 4 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warrenty Against Manufacturing Defects 5 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 6 Analog Cro, 30 Mhz, Dual Trace 0-600V, Ac / Dc 7 Trainer Kit To Study Switching Characteristicsand Vi For Scr, Igbt, Scs , Triac And Diac, 0-100V Minimum, 0-5A Load Current 8 Scr Trainer , 0-100V, 0-5A 9 Scr Firing Trainer, R Firing Trainer, 10-90 Degree For 230V Supply, 50Hz 10 Ujt Trainer, Upto Khz, Amplitude 0-60V 11 Scr Commutation ( A, B, C ) Trainer , Compatible To 230V Ac, 50Hz 12 Scr Commutation ( D, E, F ) Trainer, Compatible To 230V Ac, 50Hz 13 Half Controlled Rectifier, 0-100V 14 Full Controlledrectifier, 0-100V 15 Ac Regulator Trainer, Compatible To 230V, Variable Output Upto 230V 16 Dc Series Motor Drive Using Scr, Drive Should Be For 3Hp Motor 17 Separately Excited Shuntmotor Drive Using Scr, Drive Should Be For3 Hp Motor Atleast. 18 Setup To Study Speed Control Of 3-Phase Induction Motor Using Pwm, Drive Should Be 35Hp Motor 19 Flat Plate Solar Collector, Collector Body-Sturdy, Pure Polyester, Powder Coated Frame, 2Sqm, 9 Nos. Copper Fins And Tubes. 20 Vi Charactertics Of Pv Cell Trainer Kit 21 Solar Water Heating System 22 Pyranometer, Sp [ Ecial Selectivity ( 350 To 1500 Nano Mete, Tilt Responce-0-90◦ At 1000W / Sq.M, Temp Response – ( -10 ) Degree, Field Of View 180◦ 23 Solar Cooker, Frp Body, 23”X23”X9”, Reflector Material-Mirror Glass 4Mm, 4 Nos Aluminium Container Covered With Toughened Glass 4Mm, Plain Glass 4Mm, Insulation Material – Glass Wool, Inbuilt Analog Temperature Meter. 24 Flat Plate Solar Collector 25 Power Factor Improvementby Static Capacitor, 12.5 Μf, 450V, 200 Mhenry / 1Amp, Resistance 500Ω / 400W, Auxiliary Power Supply 230V Ac, 50Hz, Mcb 2Amp 26 Pelton Wheel Water Turbine Cut View Model 27 Franciswater Turbine Cut View Model. 28 Kaplan Water Turbine Cut View Model 29 Dc Series Motor Drive Using Step Down Chopper, Compatible Upto 3Hp 30 Synchronous Motor And Panel For V Curve Plotting, 415V, 3Hp With Required Control Panel. 31 3 Phase Resistive Load Box Upto 15 A, 415 V 32 Time Period Of Oscillation Of A Cantilever-Metre Scale ( Wooden - 2 Nos. ) , G. Clamp ( Metallic ) -02 Nos, Slotted Weight ( 4 No. Each Of 50 Gm ) Brasssed Chromed-02 Set. Slotted Weight Holder With Hook ( Metallic ) -05 Nos. Stop Watch ( Dial 30 Sec, Max Time Time 30 Minutes, Least Count 0.1 Sec, Made Of Stainless Steel, Tested At Nabl Acreditated Lb 33 To Verify Kirchhoff’S Law Using Electrical Circuitsi ) Kirchoffs Law Trainer Kit With Meters ( Standard ) Ii ) I.C Regulated Power Supply, Output : 0-9 V, 0.2 Volt / Div @ 500 Ma Over Voltage And Over Current Protectioniii ) Variable Resistors ( 0 To 10K, 3 Values ) Plug Type Resistance Box ( Standard Quality Manganin Coils ) Iv ) Digital Multi-Meter:01 No. Dc Voltage: 0-200 Mv- 1000V , Dc Current: 0-20 Ma -10A, Ac Voltage: 0-20V- 700V, Ac Current: 0-20Ma-10A , Resistance : 0-200 Ohm -2 Mega-Ohm. Capacitance: 0-20 Nf- 200Μf, Frequency: 0-200 Khz, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 34 Galvanometer By Half Deflection Method.Tablei ) Table Galvanometer ( Moving Coil Weston Type ) - 3 Nos. ( Known Resistance And Figure Of Merit ) , Range : 30-0-30, Sensitivity : 2 Micro-Amp / Div ; Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250Mm X 200Mm, Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. Ii ) Battery Or A Battery Eliminator ( 0 - 6 V ) - 03 Nos.Iii ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) , Range In Ohms :0 To 10K Ohmsiv ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) - , Range In Ohms :0 To 200 Ohms., V ) Fractional Resistance Box, - 03 Nos. Range : 0 – 10 Ohm Vi ) One Way Keys ( Standard - 01 No. Pack Of 5 Nos. ) , Brass Block With Brass Terminals. Block Size: 56 X 10 X 10 Mm. Vii ) Digital Multi-Meter- 01 No.Specification Issame As Item No 33. ( Iv ) , V ) Connecting Wires ( Standard, 1 Coil Each ) - 35 Conversion Of Galvanometer Into An Ammeter Or A Voltmeter.I ) A Galvanometer, ( Known Resistance And Figure Of Merit ) , Specification Issame As Item No 3 ( I ) . ( Ii ) , A Battery Eliminator ( 0 – 3V, - 03 Nos.Iii ) One Way Key ( Standard ) - 01 Nos., Specification Issame As Item No 34. ( Iv ) Iv ) Wire Rheostat - 04 Nos. Range 0 – 200 Ohm, Length : 30 Cm, Dia 50 Mm ( Approx ) , Current : 2.5A , Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab. V ) Dc Milli-Ammeter - 03 Nos., Range 0-30 Ma , ( Div. 1Ma ) , Accuracy : + / - 1%, Permanent Magnet Moving Coil Type. Bakelite Case, Size: 250 Mm X 200 Mm. Anti-Parallax Mirror Scale, Knife Edge Pointer, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab.Vi ) Dc Voltmeter - 03 Nos. Range 0 – 3 V, ( Div. 0.05 V ) , Accuracy : + / - 1%., Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm. Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab.Vii ) Constantan Or Manganin Wire ( 26 Or 30 Swg, 10 Nos. ) , Viii ) Connecting Wires ( Standard ) . 36 Pn Jn Diode Characteristicsi ) Pn Jn Diode Characteristics Trainer Kit ( Compact ) , For Both Si And Ge Diode With, Ii ) 4Mm Bs-4 Jack Terminal For Various Test Point, Iii ) Power Led Indication, Iv ) Built Analogue Meter For Voltage And Current, Measurement - ( A ) Voltmeter : 0-3V, 0.05V / Div, ( B ) Voltmeter : 0-10V, 0.2V / Div, ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div, Measurement. ( A ) Voltmeter : 0-3V, 0.05V / Div ( B ) Voltmeter : 0-10V, 0.2V / Div ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div Micro Ammeter: 0-100 Μa, 1Μa / Div Variable Voltage Range By Potentiometer Arrangement : 0- 1.5V ( Forward Bias ) And 0 - 10V ( Reverse Bias ) Built In Regulated Dc Power Supply Ac Input : 230V Ac, 50Hz, +- 10%. Mounted On A Sophisticated Cabinet Accessories : Patch Cords. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 37 Po Box Experiment ( To Verify Series Law ) Post Office Box. ( Plug Type ) With .. Body Made Of Brass Inside Teak-Wood Made Case. Manganin Wire, Non Inductive Winding. Ratio Arms 10, 100, 1000 Ohm, Series Arms 1 To 5000 Ohm, 16 Coils. Two Tapping Keys ( 2 Mm Thickness ) For Galvanometerand Battery. Brass Made Plug Key ( Dia 7Mm, Length 20Mm Excluding Head ) And Brass Made Stud ( Thickness 12 Mm , Height 15 Mm ) . Connecting Terminals Should Have Heavy Threaded Knob. Wired Wound Resistor ( Fixed ) : Iso 9000 Certified Manufacturer. 5 Ohm, 1% Tolerance; - 10 Nos. 10 Ohm, 1% Tolerance;- 10 Nos. 20 Ohm., 1% Tolerance;- 10 Nos. Insulated Copper Wire For Electrical Connection, -2Roll Area 1.5 Square Mm. 38 To Verify Snell’S Law Of Refraction Of Light - 15 Set Rectangular Galss Slab , Crown Glass - 15 Nos Size : 4 Inch X 3.5 Inch X 1 Inch Drawing Board Made Of Soft Wood - 15 Nos Size : 18 Inch X 23 Inch, Good Quality. Stout Hair Pin.- 5 Box Board Pin - 5 Boxwooden Meter Scale ( 1 M ) - 2 Nos 39 Ohm’S Law Verification - 2 Set Ohms Law Apparatus Kitwith Built In ( Compact ) -2 Nos Dc Voltmeter, Range 0 – 3 V - 2 Nos Specification Issame As Item No 36. ( Iv ) Dc Milli-Ammeter - 3 Nos Range 0 To 500 Ma ( Div. 5 Ma ) , Accuracy : + / - 1% Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm, Knife Edge Pointer, Anti-Parallax Mirror Scale, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab 40 To Verify Inverse Square Law Of Radiations Using A Photo Electric Cell. - 2 Set Photo Cell ( Selenium ) ( Mounted In The Metal Box With Connections Brought Out At Terminals ) Lamp Holder With Bulb ( 60W Bulb ) Moving Coil Analog Micro Ammeter Mounted On The Front Panel And Connections Brought Out At Terminals ( Range 0 - 500Μa ) . Moving Coil Analog Milli-Voltmeters Mounted On The Front Panel And Connections Brought+ Outat Terminals ( Range 0 -1000 Mv ) Wooden Bench Fitted With Scale ( Range ) Connecting Wires ( Standard, 1 Coil ) .- 1 Coil, 41 Capacitance And Permitivity Kit ( Digital ) ( To Determine The Permittivity Of Air At A Place ) - 2 Set 42 Focal Length And Magnifying Power:U-V Method. Optical Bench And Its Acessories ( Complete Set ) : 3 Sets Twin Bar 1.5 Meter Long Made Of Brass Chrome Plated Pipes Held In Strong Supports With Leveling Screws. One Pipe Is Graduated In Mm. Four Sliders With Four Sliders With Index Mark . Two Lens Holders And Two Pin Holders ( Made Of Brass ) Having Screw In Each Which Has Capability Of Vertical And Horizontal Displacement And With Two Pins Made Of Brass ( For The Determination Of Focal Length Of A Convex Lens By U-V Method ) . Spherical Double Convex Lenses With - 3 Nos Focal Length – 10 Cm, Diameter 60 Mm - 3 Nos Focal Length – 15 Cm, Diameter 60 Mm - 3 Nos Focal Length – 20 Cm, Diameter 60 Mm.- 3 Nos 43 Radius Of Curvature Of Concave / Convex Surface - 5 Nos Spherometer ( Complete Set ) With Linear Scale In Mm Circular Scale Divisions:100 Convex Mirror - 5 Nos Concave Mirror - 5 Nos Plane Glass Slab ( Big Size ) - 5 Nos Plane Mirror - 5 Nos 44 Spring Constant By Hooke’S Law Apparatus - 3 Set Retort Stand With Clamp, Spring With Hook At Both Ends, Weight Hanger With Hook ( 50 Gm ) Slotted Weight ( A Set Of Six ) 50 Gmeach A Vertical Wooden Scale A Fine Pointer 45 Co-Efficient Of Static Friction Between Wood And Glass. Horizontal Wooden Board With Glass Top, Fitted With Pulley At One End. Wooden Block ( With Slots On Top For Weight ) With Fixed Hook At One End. Weight Hanger With Hook. Slotted Weight ( 10 No. Each Of 20 Gm ) 46 Moment Of Inertia Of A Flywheel. Flywheel With Shaft. Weight Hanger. Stop Watch Meter Scale Slotted Weight ( Standard Set ) 47 Co-Efficient Of Linear Expansion Of A Metal Rod Pullinger’S Apparatus, With Scale And Thermometers. Optical Level High Resolving Power Telescope Meter Scale Thermometer A Metallic Rod 48 To Verify Boyles Law Boyles Law Apparatus : Complete Set With Accessories: Burette Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking Fitted On A Teak Wood Made Frame ( Height 120 Cm, Width 10 Cm., Thickness 2.5 Cm ) With A Metrescall Attached At The Middle Of The Frame And Standing On A Cast Iron Made Base ( Length 22 Cm And Breadth 5 Cm ) Having Three Legs Two In Front And One At Back Side Each Having Length 8.5 Cm. ) . Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod ( 8 Mm Dia ) . High Quality Synthetic Tube ( 1.0 M Long ) Containing 750 Gm Hg. One Spare Synthetic Tube. ( With Extra 500 Gm Mercury ) . Fortin’S Barometer : ( Complete Set ) Brass Made, Supplied With Mercury Andcase Made Of Teak Wood. Open Plate Reflectors, Ringand Screws For Vertical Adjustments. A Dual Scale Graduated In 25 To 32 Inches And 64 Cm To 81Cm Is Read By Verniers Moving By Rack And Pinion, Reading To0.01 Inch And 0.1Mm Are Enclosed In A Glass Cylinder.A Glass Cistern At The Lower End Of Barometer Isprovided With An Ivory Point To Adjust The Level Of Mercury. Mounted On A Wooden ( Teak Wood ) Base. Covered With Glass Case. A Thermometer Is Provided On The Wooden Base. 49 To Find The Viscosity Of A Given Liquid ( Glycerin ) By Stokes Law With The Following Stake’S Law Apparatus For Viscosity Measurement : Neutral Glass Thick Tube About 1.25 Inch Diameter And 1 Meter Long Fitted On A Teak Wood Made Wooden Stand With A Meter Scale. The Glass Tube Is Having A Nozzle At The Bottom Fitted With A Rubber Tube And Pinch Cock. A Net Hanger And A Small Spherical Ball Of Three Different Dia ( 5 Each ) . Glycerine : 2 ( Two ) Litre Per Apparatus Castor Oil: 2 ( Two ) Litre Per Apparatus Screw Gauge Stop Watch Meter Scale 50 Relative Density Of Sand By Specific Gr. Bottle Hydrostatic Balance: Capacity 250G And Sensitivity 1 Mg, Body Made Of Teak, Wood, Made Of Brass With Others Accessories ( For The Determination Of Specific Gravity Expt. ) .Std. Weight Box:Chrome Plated Brass Weightsin Box, Containing From 1Mg To100g ( Grade “A” ) Isi Standard . Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accredited Lab.- 4 Nos. Beaker, 150 Ml Capacity, Borosil. - 5 Nos. Beaker, 100 Ml Capacity, Borosil. - 5 Nos. Specific Gravity Bottle, 50 Ml Capacity. - 20 Nos. Wooden Bridge ( Teak Wood Made ) . - 5 Nos. 51 Computer -Key Highlightsprocessor- ( Intel 7Th Gen Or Amd Ryzen 3000 Series / Threadripper 2000 Series ) Or Higher Cpu Operating System- Microsoft Windows 10 ( 64-Bit ) , Version 1909 Or Laterram- 8 Gb Ddr4 Or Higher Storage- Recommended Ssd- 240 Gb Or Higher For C Drive And 1 Tb Hdd Or Higher For Storage 52 Laser Printer-Hp Laser 108A Single-Function Printer 53 Printer Cartridge-For Hp Laser 108A Single-Function Printer 54 Barcode Label Printer-Model Tvs Lp 46-Product Dimensions ‏ : ‎ 18.5 X 21 X 28 Cm; 4.52 Kilograms Manufacturer ‏ : ‎ Tvs Electronics Limited Asin ‏ : ‎ B08gsr5n6j Item Model Number ‏ : ‎ Lp 46 Neo Manufacturer ‏ : ‎ Tvs Electronics Limited Item Weight ‏ : ‎ 4 Kg 520 G Item Dimensions Lxwxh ‏ : ‎ 18.5 X 21 X 28 Centimeters Generic Name ‏ : ‎ Label Printer 55 Ribbon-Sun Retail 105Mmx300mts Thermal Transfer Barcode Labels Ribbon Super Wax For Printer ( Wax ) For Citizen Zebra Tvs Tcs Hbrt Godex Printer Paper Label ( Black ) 56 Paper Roll-Best Label Hub50x25 ( Thermal ) Barcode Labels Stickers, 4000 Label In Roll, 2Up 57 Bar Code Scanner-Tvs Electronics Bs-C101 Star Barcode Scanner | With A Top Trigger Button | 1D Linear Imager To Scanner | Speed Of 330 Scans Per Second | Enabled With Ultra Scan-Decoding 58 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmer A Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers.Support Almost All Pics.This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc.Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 59 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Id Ekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 60 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 61 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warranty Against Manufacturing Defects 62 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 63 Speaker Trainer To Study The Frequency Response And Directivity Characteristics. Built In Dc Power Supply, Audio Frequency Generator, Suitable Amplifier With Gain Adjustment, Sound Level Meter, 360 Degree Circular Scale With 2 Ft Diameter With Holding Structure, Clearly Printer Front Panel, Instruction Manual 64 To Study The Internal Layout Of B&W Tv Receiver And Measure Voltage Level To Sketch Composite Video Signal At Different Stages Of Tv Receiver:B&W Tv Receiver Trainer With Built In Facilities To Observe Composite Video Signal, Vertical And Horizontal Signal, Crt Based B&W Kit, Adjustment Must Be Provided For Sound, Vertical And Horizontal Amplifier In Front Of The Panel, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 65 Study Of Internal Layout Of Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 66 Fault Finding In Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Different Fault Switch To Be Provided To Create Fault And Observe The Results, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 67 Test Various Sections Of Led Tv Receiver: Led Tv Trainer To Test Different Sections, Power Supply, Processor Card, , Led Screen, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 68 Dth Trainer With Tools For Installation 69 Demonstration Of Photocopier Trainer: Photocopiertrainer To Study Its Demonstration Working, Clearly Printed Front Panel, Instruction Manual 70 Demonstration Of Microwave : Microwavedemonstration Set Up To Study Its Working, Clearly Printed Front Panel, Instruction Manual 71 Demonstration Of Washing Machine: Washing Machine Demonstration Setup With Clearly Visible Transparent Cover, Clearly Printed Front Panel, Instruction Manual 72 Demonstration Of Refrigerator: Refrigeratortrainer With Facilities To Measure Different Parameters Like Voltage, Current, Power, Efficiency And Compressor Load, Clearly Printed Front Panel, Instruction Manual 73 Demonstration Of Digital Camera:Branded Digital Camera Demonstrator With Clearly Visible Parts. 74 Measurement Ofunknown Inductance By Maxwells Bridge:Maxwells Bridge Trainer For Measurement Of Unknown Inductance, 1 Khz 10V P-P Sine Wave Ac Source, Three Different Unknown Inductors, Suitable Bridge Balance Facility With Null Detector, Clearly Printed Front Panel, Instruction Manual 75 Lvdt Trainer Kit With Built In Power Supply, On Board Printed Diagram, Measuring Range Of Lvdt ( -10Mm To +10Mm ) , 1 Khz Ac Source, Digital Display For Voltage, Clearly Printed Front Panel, Instruction Manual. 76 Strain Gauge Trainer, Load Cell Strain Gauge Platform With Changeable Compression / Tension Mode, Suitable Instrumentation Amplifier, 500 Gm Weight Box, Calibrated Digital Display, Clearly Printed Front Panel, Instruction Manual. 77 Characteristics Of Rtd ( Pt100 ) : Trainer Kit To Measure The Temperature And Change Of Resistance Of Rtd, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual. 78 Characteristics Of Thermister: Trainer Kit To Measure The Temperature With Thermister, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual 79 Calibrate Single Phase Energy Meter With Phantom Load:Energy Meter Trainer Kit With Phantom Load Arrangement, Digital Voltmeter, Ammeter, Wattmeter, Single Phase Energy Meter, Clearly Printed Front Panel, Instruction Manual. 80 Calibrate Voltmeter With Cromptons Potentiometer: Calibration Set Up For Voltmeter, Volt Ratio Box, Standard Cell, Crompton Potentiometer, Mi / Mc Voltmeter, Clearly Printed Front Panel, Instruction Manual. 81 B-H Curve Experiment Training Kit 82 Hot Air Soldering Stationfor Smd Component Rework 83 Pid Controller Training 84 Bench Top Do Meter : Dissolved Oxygen Measurements In Ppm, Mg / L Or % Saturation.Accurate Readings In Varying Conditions With Temperature, Salinity And Barometric Pressure Compensation. Large Easy To Read Display. Ready Indicator Lets You Know When Readings Are Stable. Non-Volatile Memory Holds Up To 100 Data Points. Integral Electrode Holder Dissolved Oxygen Range0 To 30Mg / L % Saturation Of Oxygen Resolution 0.1% / 1%Resolution 0.01 Mg / L Accuracy ±0.5% Full Scale Salinity Correction Range 0 To 50 Ppt Temperature Resolution 0.1 Range Accuracy ±0.50C / ±0.90F 0 To 1000C / 32 To 2120F Resolution 0.1 Barometric Pressure Correction Power Range 450 To 825 Mm Hg 110 / 240 V Ac Smps 9V Dc Adapter 1.3 A. Range 450 To 825 Mm Hg110 / 240 Ac Smps 9V Dc Adapter 1.3 A Resolution 1 Accuracy Manual Input Method Galvanic 85 Conductivity Meter / Tds: For Routine Applications In Laboratories, Production Plants And Schools. Must Be Reliable, Accurate And Consistent Performance. Large Screen That Displays Conductivity Or Tds Readings With Temperature In 0C And 0F. Ready Indicator To Know When Readings Are Stable. Selectable Cell Constant Auto-Ranging Across 5 Conductivity And Tds Ranges Up To 5 Point Push Button Calibration Non-Volatile Memory Hold Up To 100 Data Points Integral Electrode Holder, Automatic Temperature Control Probe. Conductivity Range .1Μs / Cm To 200.0Ms / Cm Resolution 0.01Μs; .01Μs; 1Μs; 0.01Ms; 0.1Ms Accuracy ±1% Full Scale Cal. Points Automatic ( 4 Points ) Maximum 1 Per Range; Manual ( 5 Points ) ; Maximum 1 Per Range Cell Constant .01, 1.0 10.0 ( Selectable ) Tds Range 0.1 To 100 Ppt @ 0.5 Tds Factor ( To 200Ppt @ 1.0 Tds Factor ) Resolution 0, 01Ppm; 0.1Ppm; 1Ppm; 0.01Ppt; 0.1Ppt Power 110 / 240 V Ac Smps, 9V Dc Adapter, 1.3 A Output Rs-232 86 Electro Pneumatic Trainer Kitthe Pneumatic Kit Shall Be Of Sleek Design And Portable One With Wheels. This Unit Is To Be Provided With Standard Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Pick & Place Of Components Easier. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”. All The Components Used Shall Be Of Reputed Make Like Festo / Janatics / Rexroth Or Any Other Reputed Make Acceptable To Polytechnic. Vendor Has To Specify The Make With Catalogue.The Following Experiments Should Be Possible To Carry Out Using The Kit:A ) To Learn About The Fundamentals Of Pneumatics With Components ( Frl Unit, Compressor, Dc Valves, Pressure Control Valves, Pneumatic Cylinders, Accessories, Etc ) – Functions, Symbols, Working Principle & Applications. B ) To Build Up A Pneumatic Circuit With Applications Like Lifting & Holding A Load, Clamping / De-Clamping, Speed & Load Control In Double Acting Cylinder, Speed Control Of Pneumatic Motor Etc. Vendor Has To Provide The Learning Resources – Basics Of Pneumatics, Different Pneumatic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) :1. Air Compressors- Displacement 3Cfm, Working Pressure – 7Kg / Cm2 ( 7 Bar ) With 0.5Hp 650 Rpm Electric Motor 230V, 50Hz, 1 Phase With 0-10 Bar Pressure Gauge & Shut Off Valve With Suitable Hose And End Connector. 2. Filter Regulator And Lubricator ( Frl ) Unit With Pressure Gauge ( 10Bar ) – 1 No. 3. Direction Control Valves Of Different Configuration ( 5 / 2 Way Lever Operated -4 No., 5 / 2 Way Single Solenoid Operated - 2 No., 5 / 2 Way Double Solenoid Operated -2 No, & 5 / 3 Way Lever Operated - 3 No, 3 / 2 Way Roller Operated Valve – 1 No ) . The Size Of The Valves Shall Be Of ¼” Bsp. 4. Set Of Pressure Control Valves, One Way Valves, Flow Control Valves, Shut Off Valves, Or Gate & And Gate Shuttle Valves, Time Delay Valve, Quick Exhaust Valve ( Minimum – 1 No Each ) Or Of Sufficient Quantity To Execute The Experiments. The Size Of The Valves Shall Be Of ¼” Bsp. The Vendor To List Down The Type, Specification And Quantity Of Valves Offered. 5. Single Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement –1No. 6. Double Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement - 2 Nos. 7. Pneumatic Motor - 1 No, 8. Required Length And Quantity Of Pneumatic Hoses With Suitable End Fittings Of Quick Snap Type And Ell, Straight & Tee Fittings Of Required Quantity Have To Be Provided. 50% Extra Spares Of This Hoses And Fittings To Be Supplied. Details Of Supply Are To Be Specified In The Offer. 9. Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied.10. Required Electrical Controls With Sockets For Solenoids, Etc. Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 87 Electro Hydraulic Trainer Kitspecification: 1. The Hydraulic Kit Shall Be Of Sleek Design And Portable One With Wheels. 2. Provided With Standard Steel / Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Mounting Of Components Easier. 3. All The Products To Be Provided With Suitable Quick Disconnect Couplings. 4. All The Components Used Shall Be Of Reputed Make Like Rexroth / Vickers Or Any Other Reputed Make Acceptable To Polytechnic. Vendor To Specify The Make With Catalogue. 5. The Following Experiments Should Be Possible To Carry Out Using The Kit: A ) To Learn About The Fundamentals Of Hydraulics With Components ( Dc Valves, Pressure Control Valves, Flow Control Valves, Hydraulic Cylinders, Accessories, Etc., ) B ) To Build Up A Hydraulic Circuit With Applications Like Hydraulic Press Circuit, Clamping / De-Clamping, Meter-In / Meter-Out, Speed Control & Load Control In Double Acting Cylinder, Sequencing Circuit, Counter Balance Circuit, Etc. 6. Vendor To Provide The Learning Resources – Basics Of Hydraulics, Different Hydraulic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. 7. Operation & Maintenance Manual To Be Supplied - 2 Hard Copies And 1 Soft Copy With The Equipments. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) : 1 ) Trolley With Frame, No. Of Wheels - 4, Two Fixed & Two Swivel Type. Load Mounting Capacity: 500 Kg 2 ) Hydraulic Power Pack With Following Capacity: Operating Pressure: Around 40 Bar. Flow Rate: Around 5 Lpm. The Power Pack Includes The Following Components: A ) Hydraulic Tank Capacity Around 50 Litres. B ) Suitable Pump & Electric Motor ( Single Phase – 230V, 50 Hz, 1440 Rpm Induction Motor ) Coupled With Bell Housing And Mounted Externally Over The Tank With Vibro-Mounts. C ) Safety Relief Valve With Variable Pressure Setting. D ) Accessories Like Drain Plug, Suction Strainer, Return Line Filter, Electrical Power Source For Solenoid Valves, Valve Mounting Sub-Plates, Hydraulic Fittings, Etc. E ) Required Quantity ( Min. 8 Nos. ) Of Hydraulic Hoses Of Suitable Length With End Fittings And Quick Couplings, Transparent Hoses On Return Lines And Leakage Lines. 3 ) All Types Of Valves To Carry Out The Experiments Proposed. The Valves Include: A ) Solenoid Operated Dc Valves – 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types ( Solenoid Voltage: 24V Dc ) B ) Manual Operated Dc Valves 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types. C ) Pilot Operated Dc Valve4 / 2 Way – 1 No And 4 / 3 Way – 1 No D ) Pressure Relief Valve – 1 No E ) Pressure Reducing Valve – 1 No F ) Pressure Sequence Valve – 1No G ) Flow Control Valve – 1 No H ) Non-Return Valve- 1 No 4 ) Hydraulic Cylinders – A ) Single Acting Cylinder – Spring Return Type ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) B ) Double Acting Cylinder ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) Seals: Bushak&Shamban / Merkel / Freudenberg Or Any Other Reputed Make Acceptable To Polytechnic. Max Operating Pressure: 100 Bar, Normal Operating Pressure: 40 Bar Piston Rod: Chrome Plated And Hardened. 5 ) Hydraulic Motor: Type: Gear Motor / Piston Motor Direction Of Rotation: Bi-Directional Normal Operating Pressure: 40 Bar, Max. Pressure: 100 Bar, 6 ) Flow Meter – 1 No Type: Acrylic Hone Type Flow Meter With Scale, Rotameter, Working Pressure: Around 40 Bar 7 ) Proximity Sensor: 2 No Type: Contact Less Proximity Sensor Pnp Type, Operating Voltage: 24 V Dc, 8 ) Equipment Trays: 4 No, The Tray Design Is Such That The Supplied Components Can Be Kept In The Tray. Also The Trays Have Space For Each Individual Component. 9 ) Pressure Gauges – 5 No ( Glycerine Filled ) Of Suitable Range To Measure The Pressure At Various Points ( Pressure Line, Return Line, Reduced Pressure Line, Suction Line, Etc. ) 10 ) Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied. 11 ) Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 12 ) Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 88 Separating & Throttling Steam Calorimeter With Boiler Specification-This Set Up Mounted On A Bench Fully Instrumented To Determine Quality Of Steam At Pressure Of Steam 8.0-10.0 Kg / Cm2 Using Separating Throttling Calorimeter With Steam Condensing Plant, Non Ibr Small Steam Boiler Shell Fitted With Immersion Heater And Furnish With Safety Valve, Pressure Gauge, Digital Thermometer, Steel Lagging Jacket, Power Supply For Heating: 230 V, Single Phase Ac. Arrangement For Drainage Of Waste Water After Experiment. Operation & Maintenance Manual. 89 Spanner Set8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19 Mm Combination Spanners 90 Spanner Set 1 / 8 X 3 / 16, 3 / 16 X 1 / 4, 1 / 4 X 5 / 16, 5 / 16 X 3 / 8, 3 / 8 X 7 / 16, 7 / 16 X 1 / 2, 1 / 2 X 9 / 16, 9 / 16 X 5 / 8, 5 / 8 X 3 / 4 91 Supply And Installation Of Izod And Charpy Testing Machine With Specimen For Testing 92 Supply And Installation Of Torsion Testing Machine. Capacity 200 Nm, Power Supply- 260Vac At 50 Hz, 12 Months Warranty From The Date Of Installation, Least Count 0.1 Degree ( Deflection ) , Measuring Units- Nm, Ncm, Kgcm ( Selectable ) , Maximum Deflection- 180Degree, Accuracy + 1% Of The Reading 93 Electrode Holder Full Brass Body Inside 5Mm Electrode Size Dimensions ( Lxwxh ) -23.6X3.5X8.9 Mm Insulated Handle Made Of Fiber Glass Polyamide And Head From Dmc 94 Lathe Machine Hmt Lathe Machine, Nh22 Height Of Centers:220 Mm Swing Over Bed:500 Mm Swing Over Cross Slide: 270 Mm Swing In Gap ( Optional ) : 720 Mm Distance Between Centers: 1000 Mm Spindle Nose / Bore- A2-6* / 53 Mm Spindle Speed Range: 16 From 40 Rpm-2040 Rpm Forward And 7 From 60 Rpm-1430 Rpm Reverse Spindle Power= 11 Kw, Feed Range ( Longitudinal ) : 60 From 0.04- 2.24 Mm / Rev, Feed Range ( Cross ) : 60 From 0.02-1.12 Mm / Rev Lead Screw Pitch- 6 [ Or 4Tpi Acme ] Mm, Metric Threads: 48 From 0.5-28 Mm, Main Motor Power=7.5 ( Std. ) / 11.0 ( Opt. ) Kw, Tailstock Sleeve Travel= 200 Mm 95 Brinell Microscope Lamp 96 Coefficient Of Friction Tester Coefficient Of Static Frictio Tester ( Analogue ) 97 Experimental Setup For Determining Modulus Of Rigidity , Strain Energy, Shear Stress And Stiffness By Load Deflection Method ( Closed Coil Helical Spring ) Setup, Installation And Demonstration 98 Supply And Installation Of Morse Test Experimental Setupnumber Of Cylinder - 4 Cylinder 99 Model Of Impulse Steam Turbine Axial Flow Impulse Turbine 100 Layout Of Hydroelectric Power Plant Including Dam, Reservoir, Penstock, Nozzle, Hydraulic Turbine, Surge Tank Etc. ( All Models ) 101 Sprit Level 102 Bevel Protractor With Tapered Specimen For Angle Measurement 103 Gear Tooth Vernier Calliper Graduation-0.02 Mm, Accuracy -0.04 Mm 104 Tachometer Testing Range- 2.5 To 99999 Rpm, Resolution- 0.1 Rpm ( 2.5 To 999.9 Rpm ) And 1 Rpm ( Over 1000 Rpm ) , Accuracy- +0.05%, Detecting Distance: 2 To 20 Inch 105 Screw Pitch Gauge Range 0.25- 6.00 Mm Thread 106 Radius And Fillet Gauge Range 1 Mm To 7Mm 107 Plug Gauge And Ring Gauge Supply Of Plug Gauge ( 1 Unit ) And Ring Gauge ( 1 Unit ) 108 Sheet Metal Gauge Minimum Range 1 Mm To 30 Mm 109 Cut Section Model Of Shell & Tube Type Heat Exchanger 110 Cut Section Model Plate Type Heat Exchanger 111 Experimental Setup For Determination Of The Thermal Conductivity Of A Solid Metallic Rod 112 Cut-Section Model Of Check Valve 113 Cut-Section Model Of Needle Valve 114 Tig Welding Machine With Gas Cylinder 115 Projector : Projection System: 3Lcd Technology, Rgb Liquid Crystal Shutter Lcd Panel: 0.55 Inch With C2 Fin Colour Light Output: 3, 600 Lumen-2, 400 Lumen ( Economy ) White Light Output: 3, 600Lumen Resolution: Xga, 1024 X 768, 4:3 Native Contrast: 16, 000 : 1 Lamp: Uhe, 210 W, 6, 000 H Durability, 12, 000 H Durability ( Economy Mode ) Keystone Correction: Auto Vertical: + / - 300 , Manual Horizontal: + / - 300 Colour Reproduction: Upto 1.07 Billion Colour Throw Ratio: 1.48-1.77:1 Zoom: Manual, Factor: 1.2 Screen Size: 30Inches - 300 Inches Projection Lens F Number: 1.49 - 1.72 Projection Lens Focal Length: 16.9 Mm - 20.28 Mm Image: Optical: Specification For Laser Printer: Specification For Projector: Technology: Offset: 8:1 Usb Display Function: 3 In 1: Image / Mouse / Sound Interfaces: Usb 2.0 Type B, Rs-232C, Ethernet Interface ( 100 Base-Tx / 10 Base-T ) , Wireless Lan A / N, 5Ghz ( Optional ) , Vga In ( 2X ) , Vga Out, Hdmi In, Composite In, Stereo Mini Jack Audio Out, Stereo Mini Jack Audio In ( 2X ) , Cinch Audio In, Usb 2.0 Type A Other Feature: Av Mute Slide, Automatic Keystone Correction, Built-In Speaker, Digital Zoom, Direct Power, On / Off, Document Camera Compatible, Easy Osd Presetting, Horizontal And Vertical Keystone Correction, Network Projection, Osd Copy Function, Pc Free, Quick Corner, Split-Screen- Function, Iprojection App, Iprojection Set-Up By Nfc, Iprojection Set-Up Qr Code Warranty: 3 Years On Projector, Lamp: 1 Year Or 1, 000 Hours Whichever Is Earlier
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 16
West Bengal View Result →
25.
Drinking Water Supply and Sanitation #10285923 Price Bid
Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments / Irp At Water Supply Scheme Kharbatpora Ratnipora - Iron Removal Plant:Design, Supply, Installation Testing & Commissioning Including 5 Years Operation & Maintenance Of Iron Removal Plant With All Allied Works Confirming To Relevant Bis / Is Code. The Job Shall Include Cost Of All Necessary Allied And Required Items Connections, Valves, Electromechanical Work, Pipe Network Including Civil Works As Per Requirement Of Site. The Agency Shall Have To Submit Detailed Design / Constructions And Shop Drawings For Approval To The Department Before Execution Of Works. All The Equipment And Item Installed Shall Be From Reputed And Standard Manufacturers, Suppliers With Proven Track Records Approved By Required Technical Data Sheets, Certificates From Authorities And Third-Party Inspections Report Before Dispatch And Installation. The Quantity Of Water To Be Treated Is Minimum 5.0 Litres Per Second ( Lps ) . The Agency Has To Conduct A Fresh Physio-Chemical Analysis Of Water Sample Of Production Tube Well Before Execution Of Works. The Iron Removal Plant Should Remove Iron Either Below Orup To Who Standards ( = 0.3Ppm ) . The Treated Water From Plant Should Be As Per Is 10500 / 2012 Norms.Rest Ofspecification As Per Cluase 107 Of Technical Anexure Of Sbd 3 The Contractor Shall Provide All The Material Such As Filter Media, Oxidising Media, Chemicals, Disinfecting Chemicals Lubricants, Pipe Breakage ( If Any ) Replacements As Required For Smooth Operation Of The Plant For A Period Of 5 Years. The Contract Shall Include All Kinds Of Consumables Required For Smooth Operation For A Period Of 05 Years Which Shall Be Borne By The Contractor And Have To Be Supplied And Fitted / Installed By The Contractor From Time To Time And As And When Required.Cost On Account Of 05 Year Operation & Maintenance Of Plant Involving Engagement Of Sufficient No. ( Minimum Three ) Of Skilled / Trained Person In The Said Field, Who Shall Be Responsible For Exclusivelyoperating And Maintaining The Plantfor First Three Months And Subsequently Engagement Of At Least One Number Of Skilled Labour For The Next Nine Monthsand Subsequent Half Yearly Inspections By Experts Besides Imparting Training To The Staff To Be Posted By The Department At The Said Plant And The Contractor Shall Comply With The Portions Of All Labor Laws & Rules Framed There Under, Repair / Replacement Cost, Daily Water Quality Analysis, Chemical Cost, Grease, M-Oil, Annual Painting Of Structures, Water Quality Recording , Training Of Departmental Employees Etcshall Be Included In The Contract On Sitc / Turnkey Basic. The Defective Parts Shall Have To Be Replaced By The Agency / Manufacturer During The Contract Period. The Turnkey Job Shall Include All Kinds Of Consumables And Spares Required For Smooth Operation For A Period Of 05 Years And Have To Be Supplied And Installed By The Contractor From Time To Time And As And When Required. The Firm Has To Attend The Site Immediately As And When The Quality Of Water Is Found To Be Below Acceptable Norms.Rest Ofspecification As Per Cluase 108 Of Technical Anexure Of Sbd 4 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Rest Specifications As Cluase - 8 Of Sbdsize : Dn80class: C ( Heavy ) 5 Fabrication, Providing And Fitting Of Washout Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. Size: 80Mmclass: C Class 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size 80 Mmpn1.6Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 12Of Technical Anexure Of Sbd 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size 80 Mm Pn 1.6Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 13Of Technical Anexure Of Sbd 8 Fabrication Of Gantry Mechanism / Cgi Shed / Angle Iron Sleeping Bedby Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 9 Providing, Fitting, Testing And Commissioning Ofvoltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Complete Specifications As Per Cluase - 44 Of Sbdrating::50Kva 10 Providing And Fitting Of 3-Core Flatsubmersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. Size:10Sqmm 11 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Amaron / Exide ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 12 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 13 Providing Of Good Quality Convenience And Utility Items Specicifications Are As Per Clause-57 Oftechnical Annexure Of Sbd. 14 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 15 Creation Of Pope Mounted , Outdoor Type Electric Sub Stationby Way Ofs / I / T / C Of 11 / 0.433 Kva , 3 Phase Distribution Transformer With Bimetallic Terminal Connectors Energy Level -2 Aluminum Wound Specifications Conforming To Is : 1180 ( Part 1 ) 2014 With Latest Amendments Certificaterating:63Kva Ht Transformer, 3 Phase ( Level 2 ) . Manufactures Test Certicicate To Be Apended And Rest Of Specification As Per Cluase 26 Of Sbdnote: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate 16 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Jammu And Kashmir View Result →
26.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
27.
Housing Urban and Rular Development #10263800 Price Bid
Construction of Mini CSC for PUES (Boys) at Thumbai in Cheyyar Block -- 1 Earth work excavation for foundation in all soils and sub soils to full depth etc., ordinary soil complete 2 Cement Concrete 1:4:8 (One Cement, Four sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification . 3 Random Rubble masonry in CM 1:5 foundation and basement including simultaneously flush pointingincluding curing neat finishing, etc., complete complying with standard specifiction. 4 Brick work using country bricks of size 83/4x41/4x23/4in cement mortar 1:5 (One cement and fivesand) including curing neat finishing, etc., complete complying with standard specifiction. 5 Brick jelly 40mm size for filling soak pit inner etc.,complete complying with standard specifiction. 6 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)Plinth Beam 7 Roof Beam & Roof Slab 8 Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 9 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) 10 Supplying, fabricating, erecting and fixingof UV coated Poly carbonite sheet 10mm thick tubular box section of 10 11 Supplying, fabricating, erecting and fixing of stainless steel including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. 12 Supplying, fabricating, erecting structural steel works 13 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work 14 plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 15 Finishing the top of roof with Best quality vitrified tiles of size 600mm x 600mm x 8mm of approved colour, shade & quality laid in CM 1:3 20mm thick and pointed with white cement mixed same colour pigments etc., and 2% of water proffing compound by weight of cement complying with standard specification. 16 Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)Using anti-skid tiles (Observed Data) 17 Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone M.Sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 18 Painting the walls with two coats of oil bound distember over one coat water based cement primer including cost for distember ,primer,cleaniong and scrapping the walls rendering theb walls smooth with necessory putty,brushes, scaffolding arrangements,labourb chareges,etc., 19 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 20 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 21 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with crushed stone M.Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone M.Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 22 Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat M.Sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. 23 cost and supply of wood plastic composit door 24 Supplying and fixingRCC Cover Slabincluding all the charges etc complete 25 Supplying and fixingRCC Cover Slabincluding all the charges etc complete 26 RCC slabat Collection chamber 27 Cost andSupplying and fixing in precast RCC ringlabour charges,etc., 28 Sanitary arrangements 29 110mm dia pvc pipe 30 110mm dia pvc Door Elbow 31 110mm dia pvc TEE 32 2000 lit PVC tank 33 Towords internal water supply arrangements (taps for toilet unit and electrification) 34 Cost and supply ofRCC jolly 35 Providing soak pit 36 Towords name board charge & Photo Charges 37 GST 18% 38 LWF 1%
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
28.
Public Administrative Department #10262628 Price Bid
Tender For Repair And Maintenance Work At Ward No.14 Community Hall In Nemili Town Panchayat.; 1 Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications 2 Dismantling and Removing Pressed Tiles & Weathering Course. complete complying with the standard specificaiton. (Payment for Pressed Tiles & Weathering Course) (W-0037) 3 Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum 4 Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 5 Supplying and fixing in position Cement basedhydrualically pressed Anti-Skid tiles (pattern design) 20mm thick in cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointedwith same colour of cement etc., complete as per standard specification 6 Dadooing walls withGlazed tiles of sizes 300mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. 7 Dismantling and Removing Brick / Stone Masonry in cement mortar walls under 3m high. complete complying with standard specification and as directed by the departmental officers.(W-0015) 8 Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in positionincluding furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification.(As per PWD SOR Page No 81, Code No. M - 0391) 9 Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with P trap or S trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. 10 Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications 11 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting 12 Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of U clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] 13 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 14 Painting two coats over newly plastered wallproof ready mixed plastic emulsion paint of departmental quality and of approved colour over a base coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 15 Wiring with 2x1.5 sqmm(22/0.3) PVCinsulated unsheathed Sc Cu.Conductor of 1100v grade in suitable PVC rigid Pipe on Wall and celling with PVC accessories with TW switch box with 5A F.T switch infulsh with wall, covered with hylem sheet of 3MM thick with painting of suitable colour for Concealed PVC light point/fan point(for electronic regulator).S.D : 20 16 Wiring with 2x1.5 sqmm(22/0.3) PVC insulated unsheathed Sc Cu.Conductor of 1100v grade in suitable PVC rigid Pipe on Wall and celling with PVC accessories with 150x100x113mm Teak Eood Switchbox for 5 A3 Pin non innter loking CS Plug With paining Suitable Colour With Continous Earth Wire Connection of 14 SWG TC Wire For Concealed P V C Plug Point.S.D 36 17 Supply and fixing of Single Box type 4.40 W Flu fitting compelete With coper chcke and condensor T.E round blocks on Wall or flu tube with PVC unshead copper leads from terminals to the fitting( Tube light fitting) S.D 88 18 Supply and fixing of 600mm(48) sweep AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp SD 110. 19 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 20 Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification 21 Internal Water Supply - P.V.C. Pipes (6Kg/SqCm) Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessaryscaffolding charges. 22 20mm 23 25mm 24 110mm 25 90mm 26 Supply and delivery and fixing of HDPE tankas per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,2000lit
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
29.
Public Administrative Department #10224642 Price Bid
Tender For Proposed Construction Of Thirumana Mandpamfor 300 Person Capacity; 1 Description 2 Earth work excavation for foundation in all classes of soils and sub soils and todepth as may be directed except in hard rock, requiring blasting, including initialleads and lifts and re-filling the sides of foundation, with excavated earth in 150mm layers well watered rammed and consolidated, including depositing surplus earthclearing and levelling the site, shoring shuttering baling outwater wherever necessary etc., complete complying with standard specification. 3 Boring, providing and Installing cast in-situ single under reamed piles of specified diameter and length below the sand and lime mix pile 300 mm diameter and below the foundation to carry a safe working load not less than specified, including the cost of materials, machinery and labour charges etc., all complete 4 Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification 5 Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 6 Cement concrete 1:4:8 (one cement four sand eight aggregate) using 40mm gauge hard granite broken stone jelly for foundationincluding cost and conveyance of all materials labour formixing,l aying, compacting, curing, dewatering, side shuttering, wherever necessary including curing etc.,complete complying with standard specification and as directed. 7 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, RCC floor slab, roof slab, beams, lintels,Rectandular or square columns, sunshades,vertical slab, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) 8 Column /footing, Grade beamEtc 9 Roof slab and Beams 10 Column and sunshade 11 Providing and laying in position, Standardised concrete mix M-20 grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser/super plasticier) in recommended proportions as per IS:9103 to accelerate, rated settingof concrete improve workability without imparing strength and durability without (5 cum) 7730kg, of 20mm machine crushed stone jelly and with about (3.30 cum) 5156kg, of 10 - 12 mm machine pressed stone jelly and with about (4.79 cum) 7670kg of sand, but excluding cost of reinforcement grill an fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibraters, finishing, curing etc., and providing fixtures like fan clams in the RCC floor/ roof slabs where ever necessary without clamping etc., complete as per the standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 12 Foundation and basement 13 Ground floor 14 First floor 15 Second floor 16 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) 17 Brick work in following Cement Mortar 1:5(one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 18 Foundation & Basement 19 Brick work in following Cement Mortar 1:6(one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 20 Ground floor 21 First floor 22 Second floor 23 Brick partition walls of 11.50cm thickness using best quality II class Ground moulded chamber burnt bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 24 Ground floor 25 First floor 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 28 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 29 Finishing the top of roof with one course of machine pressed tiles of size 200mm x 200mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stoneSand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers 30 Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 31 Paving the floor with joint free rectified glazed ceramic flooring tiles of size 305 mm x 305 mm x 8 mm of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 32 Dadooing walls with following best approved quality, white / colour glazed tiles ofsize 300 mm x 450 mm x 8 mm in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 33 Painting two coats of newly plastered wall surface with Water based Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 34 Supplying and fixing of Teak wood frames 127x76 mm size including cost and conveyance of all materials and all labour chargesetc., complete as per the standard specification. (below 2 m in length) 35 CRCA pressed steel Box section 18 gauge or 1.25 mm thick for door frames including providing holes and fixing wooden blocks for fixing furniture and fittings. N-0303 with powder coated primes. 36 Supplying & fixing Teak wood temple type door (Temple pattern ornamental doors with high quality teak wood (country) with 2 minimum to 7 maximum thick ornamental frames, 2 thick to 5 thick kamala (flower planks), creeper, birds, animal figures sculptures, etc., back side 1 thick to 3 plank including necessary carving, shaping, wastage, etc., as per approved plan and design. (page.no.163, 2a))including all materials, labour charges for manufacturing and fixing in position including all furniture fittings etc., complete complying with standard Specifications. 37 Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops,3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. Single Leaf 38 Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.Double Leaf 39 FRP door Sutter with FRP door frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and solid core FRP shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. M-0394 40 Supplying and fixing of PVC Sliding Door with Roller. M-0393 41 UPVC WindowSpecification:SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profilethe size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work M-0674 42 UPVC VentilatorSpecification:SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work M-0675 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mmdiaof1.60mmthickweldedtotherailing.The supports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete(M-0652) 44 Supplying and fixingmild steel grill Gate including costconveyance of all materials and fixing in position including priming coat etc complete with standard specifications. 45 Supplying and fixing of best quality 110mm Dia PVC rain water pipes including cost and conveyance of all materials and labour charges for fixing in position etc., complete. 46 Best varnish two coat for wood workincluding all materials, labour chargescomplete complying with standard Specifications. 47 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 48 Supplying and fixing in position European water closet of colour glazed earthen ware of approved quality with P trap or S trap with double flapped sheet and sheet cover with brass hinges and 10litre capacity PVC low level flusing tank with all internal fitting confirming to IS:2556 Part XII with sand cushion and forming flooring alroundthe closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connectionto cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without quality with P trap or S trap confirming to IS:2556 - leakage etc., complete complying with standard spcifications. 49 Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 50 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.)(S.no.125a, P.No.43) 51 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 52 Painting new iron works such as gate, steel doors windowsventilatorswithtwo coats of approved quality and color of synthetic enamel paint over one coat of zinc chromite primer in allfloor etc, complete complying with standard specifications. 53 Electrical Arrangements 54 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with metal box and 6A 1way modular Switch in flush with wall with suitable modular front plate cover for making good of the concealed portion for PVC concealed light point /fan point for Electronic Regulator) (4 Points Per Coil) (Anchor Roma/Equivalent)( DATA A) 55 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (DATA B) 56 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoireswith metal box and 6A 1way modular Switch in flush with wall with suitable modular front plate cover for making good of the concealed portion for PVC concealed light point /fan point for Electronic Regulator) (6 Points Per Coil) (Anchor Roma/Equivalent) (DATA -C) 57 Supply and fixing of single box type 420 W LED fitting with TW round blocks on wall or celling with PVC unsheathed Copper leads from terminals to the fitting. (DATA - D) 58 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp (SD 110 ) 59 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp (SD 107) 60 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall(SD 115) 61 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep (light duty) AC exhaust fan (SD 120) 62 Supply and fixing of 375mm (15) sweep (heavy duty) AC exhaust fan complete without provision of holes in the wall (DATA E) 63 Supply and fixing of louvers shutters arrangements for 375 mm (15) sweep (light duty)AC exhaust fan.(SD - 121) 64 Supply and fixing of9 W LED bulb for BH point(DATA F) 65 Supply and fixing of WT bulk head fitting with guard suitable for 9W CFL LED Bulb with electrical connection. SD 84 66 Supply and fixing of Havells LED Low Bay 50W Fitting with MS Clamp Set with Bolt and Nut and to be suspended with SS Chain 32 mm width with End Hooks with PVC unsheathead Copper leads from terminals to the fitting. (DATA H) 67 Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 390) 68 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40 A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 515) 69 Supply and fixing of 1 no.6/16 A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 402) 70 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 378) 71 Supply and fixing of Four pole sheet steel enclosure with 1 no 30 A FP isolator on wall and necessary connection for motor control (DATA I) 72 supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Lower end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD 440) 73 Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Lower End (DATA D) 74 supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . (SD 447) 75 Supply and fixing of 25 A flush type wallsocket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) (SD 143) 76 Supply and fixing of Havells JETAALBA - FLOOD LIGHT -70W LED Fitting with Necessary Wall Grouting clamps with Fixing bolts on ceilling with PVC unsheathed Copper leads from terminals to the fitting. (DATA J) 77 Supply and fixing of 450MM 18 Almonard Walla Fan on wall with connection. (DATA K) 78 Supply and fixing of 4 way vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4P MCB Isolator as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 574) 79 Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2 X 2.5 Sq.mm Copper Wire and making good of the concealed portion with suitable colour. (SD 337) 80 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.(Data L) 81 Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2 X 2.5 Sq.mm Copper Wireand making good of the concealed portion with suitable colour (Data M) 82 Supply and fixing of automatic electric water heater of 25 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection (SD 103) 83 Supply, erection,testing and commissioning of 1.5 Ton(4500 K.Cal/Hr) ABS Plastic split type Air conditioner confirming to is : 1391(part 2) 1992 Amdt No.1 to 2 fitted with Rotory compressor operating Refrigerant R.22/ Non CFC suitable for wall mounting for operating on 230 voltrs, 50 HZ single phase AC supply with star rating of 3 as per BEE specification and capable of performing the functions of1) Cooling 2) De humidifying 3) Air circulating4) filtering. 84 The installation works for the above split type AC units includes the followings. Mounting/fitting in door and out door units at the respective locations. 85 1. Laying Refrigerant pipe line of required length connecting both units after drilling hole/holes in the wall if required. Thickness of copper tubing shall not be less than 0.7mm. 2. Insulating the suction pipe with expanded polyethylene foam 5 mm tubing. 3. Laying 15mm dia Flexible PVC drain pipe to throw out. The condensate water being formed within Indoor unit. 4. Leakage testing the entire system with outdoor unit stand.5. Charging Refrigerant gas in the unit.6. Suitable electric wiring to be provided with 2.5 sqmm. PVC insulated copper wire between indoor and out door units up to 6 meters length and up to Switch within 3 meters of location of in door Unit. (Carrier/voltas) (DGS & D Rates) M 1986 86 Supply and installation of 4 KVA Capacity Automatic Voltage Stabilizer with time delay relay (M-1988) 87 Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD 662) 88 Supply and clarnping of 3-1/2 x 70. PVC LTUG armoured cable on post or on wall with MS clamps (SD 203) 89 Supply and frxing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection (SD 167) 90 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (SD 216) 91 Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour (SD 55) 92 Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only (SD 649) 93 Supply and fixing of TNEB metre board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12 mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V) 1 no. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter to fuse units by 16 sqmm PVC insulated copper wire with earth connection complete, (SD 133) 94 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 211) 95 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD 371) 96 Supply and fixing of 8 way vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 6 nos.63A TP MCB and 2 Nos 32A TP MCB as outgoing in flush with wall with earth connection only. Lower End(DATA N) 97 Supply and Run of 4 of 16 sq.mm (101/0.45) PVC insulated SC unsheathed copper conductor of 1100 V gradeon 7/20 GI wire for service connection mains (DATA O) 98 Supply and Run of 4 of 16 sq.mm (101/0.45) PVC insulated SC unsheathed copper conductor of 1100 V grade in25mm dia GI pipe (class B ) suitably bent at both ends with necessary angle iron upright and end support for service connection mains (DATA P) 99 Water Supply Arrangements 100 Supplying laying and jointing 50mm P.V.C pipes ( 10Kg/SqCm ) of approved quality and best variety conforming to I.S.S and with I.S.I mark, of the following sizes including cuttingand fixing to PVC specials using Adhesive but excluding cost of such specials makinggood the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. below ground level upto 0.60m height. 101 Supplying and fixing in best 50mm Gate valve and all materials labour charges and cost of conveyance all including cost etc.,complete. 50mm Gate valve should be got approved by the Executive Engineer before use on works-1.00 No 102 Supplying, laying and jointing 25mm PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 103 Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) 104 Supplying and fixing position CI Nahani Trap / Floor Trap of the following 100 x 75mm sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) 105 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 106 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 107 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) 108 Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works). 109 Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements 110 50 mm dia 111 Elbow 112 Bend 113 Tee 114 Coupler 115 25 mm Dia 116 Elbow 117 Bend 118 Tee 119 Reducer 25 mm x 20 mm 120 Coupler 121 Supply and providing 2000 litres capacity Priming Tank made up of PVC. Make: SINTEX / EQUIVALENT M-0540 122 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 123 Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements 124 110 mm Dia Special 125 Elbow 126 Elbow with Door 127 Bend 128 Tee 129 Tee with Door 130 Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers 131 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0851 132 Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0852 133 Bore well 134 Drilling od 150mm dia pilot bore well in sedimentary areas by using CalyxRig any where in thanjvur district including transportation to anoher plce in alluvial soil or sedimentary strata of clay and sand stone ,shale ,pepples boulders ect by taking a pilot bore well of 140/150mm dia and then enlarging to required dia by direct or rotray drilling mud circulation method usingrotray rig, including cost og bendinite mud for drilling at the site site shown by the TWAD board officers including construction of mud pit WD-W0783/ P-198 135 Reaming from 200mm dia pilot bore in to 400mm dia bore as directed by TWAD Board officers. WD-W0805/ P-199 136 Labour charges for inserting ofPVC casing pipe in the drilled hole( With slots and without slots) includingjointing the couplers with cement paste and packing the annular space with pebbles of approved quality. As approved by the Executive Engineer. WD-W0830/ P-201 137 Charges for developing the Bore well with compressor of 600 cfm capacity(Minimum8 hours) including trasportation ,Labour,Fuel ectfor compressor as directed by the TWAD Board officers. WD-W0833/ P-201 138 Supply and delivery of unplasticisedPlain casing pipe of the following diameters in 3m lengtheach as per ISI 12818/1982 to suit deep borefrom 80m to 250m depth(CM)for delivery at site including loading and unloading,frieght,transit insurance and inclusive of all taxes ect.complete. 139 200mm dia PVC casing pipe (CS)WD-M0030/ P-06 140 200mm Dia PVC clatted pipeWD-M0032/ P-06 141 200mm PVC End capWD-M0030/ P-06 142 MSTop End cap WD-M0738/ P-195 143 Charges for Geophysical charges 144 Supply and delivery ofOpen well Horizontaltype Submersiblepump set conforming to IS 14220 /94capable of discharging the following duties due to all causes . The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller and brass screws with ISI mark,. The pump suitable for installation in sump with 1.1KV.grade 3 coresuitable copper flat submersible cable to a length of 15metres with necessary cable joints.The non-return valve located at the top of the pump in the discharge outletconnection is to be designed with minimum friction .The pump should be directly coupled to 2880 rpm, 3 phase, 50 Hz, 415V+6% & 415V-15% squirrel cage induction motor suitable for ATS starting and for continuous operation The pump set should be provided with 5m length of suitable size PVC insulated copper flat cable for connecting the pump set, starter & Isolator. including cost ofitem 1.B50 lpm x 50m HeadWD-M1614/ P-103 145 Supply, delivery of fully auto transformer starter with single phase preventor with Ammeter etc., complete50 lpm x 50m HeadStarter WD-M1909/ P-119 146 Supply, delivery of 1.1 KV grade, 3 core PVC insulated PVC sheathed, Submersible copper cablewith ISI marking conforming to IS 694/1900 of reputed make. 2.5 sqmm copper cable WD-M1974/ P-119 147 Supply and delivery of GI pipesand GIspecials for pumpset erection work. 148 100mm GI pipeWD-M0492/ P-27 149 100mm GI Elbow WD-M0594/ P-32 150 100mm CI Foot valveWD-M0065/ P-223 151 100mm CI Sluice valve WD-M1072/ P-57 152 100mm Heavy longCoupling WD-M1974/ P-32 153 100mm GI Flange set WD-M1974/ P-32 154 110mm PVC threaded couplerWD-M0058/ P-08 155 M.S. Bolt & Nut WD-M0589/ P-31 156 Rubber insertion sheetWD-M0591/ P-31 157 M.S. Clamp setWD-M0617/ P-32 158 Labour charges for erection of2.0 HP submersible pumpset in the borewell 159 Errection of 2.0 HP submersible WD-W0855/ P-203 160 Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. 161 (a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No.,Level Switch - 1 No. &Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install theSystem in position and intact. (M-0723) - 500 Ltrs 162 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 163 Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 2
30.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
31.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
32.
Housing Urban and Rular Development #10192836 Price Bid
Tender For Providing Furniture Items In Govt. Medical College At Village Koriyawas In Mohindergarh Distt.-- 1 Providing and Placing in position Main Table with Back Unit. Overall size of the table shall be 1800 mm (L) x 900 mm (D) x 750 mm (H), Side Table 1200 mm (L) x 500 mm (D) x 750 mm (H) and integrated Pedestals 2Nos fixed type Drawer Units in each table set of size 470 mm (W) x 500 mm (D) x 725 mm (H) - one in Main table and one in Side Table. The Main Table and Side Table tops shall be made of 25mm thick MDF with bottom side pre-laminate confirming to IS-14587:1998 and 0.4mm PVC membrane pressed on to top. Soft closing access flap within-build power box are provided on work surface for wire management. The modesty panel shall be made of 25mm thick MDF - one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The understructure shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. The drawer unit shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. Drawer Units - Drawer fronts shall be made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Each drawer unit shall contain 3 drawers i.e. BoxplusBoxplusFile type which uses powder coated 400mm long metal Panel Drawer Slides. Drawer extension shall be 325mm. Drawers shall have a soft closing and anti slam mechanism. Chrome plated flat type handles shall be provided for ease of opening. Drawer units are provided with lock for security. 2 Providing and Placing in position Disply Unit. Overall size of the unit shall be Display Unit shall be 1650 mm (L) x 500 mm (D) x 1100 mm (H). The Back unit shall comprises bottom sliding storage unit and top hollow storage spcae which are covered with top panels. The top panel of the back unit shall be made up of 25mm thick MDF one side pre-laminated board confirming to IS:14587:1998 with 0.4 mm PVC membrane pressed on top. Sliding door unit shall be made of made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Shutters have a soft closing and anti slam mechanism. Handles are provided for ease of opening. Storage is provided with lock for security. 3 Providing and Placing in position Chair. The cushioned seat assembly shall be made of injection moulded plastic outer and inner. Plastic inner is upholstered with stitched cover and moulded high resiliance polyurethane foam of density 45plus /- 2 kg/m³ and hardness load of 16plus /- 2 kgf for 25% compression. The stitched cover shall be made from spacer fabric and leatherette. Seat size shall be 47 cm W x 48 cm D. The cushioned back shall be made of PU foam with insitu molded MS ERW round tube of size 1.9plus /- 0.03 cm x 0.16plus /- 0.0128 cm. It shall be upholstered with spacer fabric and leatherette. The back size shall be 45 cm W x 75.5 cm D. The armrest top shall be moulded from polyurethane and mounted on to a drop lift adjustable type tubular armrest suport made of 3.81plus /- 0.03 cm x 0.2plus /- 0.01 cm thick MS ERW tube. The armrest height shall be adjustable up to 6.5plus /- 0.5 cm in 5 steps. The armrest structure shall be powder coated DFT 40-60 microns. The mechanism shall be Bio-Syncro Mechanism with following features : 360º revolving, front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort, tilt tension adjustment can be operated in seating position, 5-position tilt limiter giving option of variable tilt angle to the chair, Seat/Back tilting ratio 1:2, the mechanism housing shall be made of HPDC aluminium black powder coated. Seat depth adjustment shall be integrated in the seat through a sliding mechanism. Seat depth adjustment range shall be from 6.0plus /- 0.5 cm. The back frame shall be connected up/down mechnism housed in plastic T spine. It can be adjusted in the range of 7.42plus /- 0.5 cm for the comfortable back support to suit individual needs. The pneumatic height adjustment shall have an adjustment stroke of 10plus /- 0.3 cm. The pedestal shall be injection moulded in black 33% glass filled nylon 66 and fittyed with 5 nos. of twin wheel castors. The pedestal shall be 66.1plus /- 0.5 cm pitch centre dia. 5 nos. of twin wheel castors shall be injection moulded in plastic having 6.0plus /- 0.1 cm wheel diameter and shall be assembled to the pedestal. Overall size of the chair shall be 76.1 cm W x 76.1 cm D x 113.6 - 131.1 cm H and seat height 44.5 - 54.4 cm. 4 `Providing and Placing in position 2 Seater Sofa for HOD Cabin. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-146.0 cm and Depth-92.0 cm. 5 Providing and Placing in position Main Table. Overall size of the table shall be 1800 W mm x 1650 D mm x 750 H mm. Worktop shall be made of Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Access Flap provided on work surface for wire management. Side table shall be Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Modesty Panel shall be made of 18mm Thick Pre-laminated twin board (PLT) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Cube legs shall be fabricated from MS ERW Tube of 50 mm x 25 mm x 1.2mm thick and 40 mm x 40 mm x 1.2 mm thick (as per IS: 7138). At the top surface of leg, support brackets of 3 mm thick HR (as per IS: 2062) shall be welded for fixing worktop. These shall be welded together by argo shield welding. This welded structure shall be coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert shall be fixed, on to which a straight M8 leveler fitted which allows for adjustment of the height upto 50mm. Cross Members shall be made from 50mm X 25mm X 1.2mm thick ERW tube (as per IS:7138). These shall be coated with 50 micron epoxy polyester coating. Cross Members shall be assembled by friction fit PDC joinery and grub screws. There shall always two cross members for one table. Soft closing access flap shall be used. Provision for standard size of 8 module electrical shall be offered. Access flap shall be made from Aluminum extrusion, PDC parts made from Aluminum Alloy and plastic parts are made from Nylon 6 and wire brush with nylon bristles. Power box made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 Module cutout provision). This shall be fixed with worktop along the depth at Access Flap position. Hinge Door Unit shall be made of 18mm Thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Door shall be fixed with slide on hinges and handle is provided for ease of opening. Drawer shall be provided with ebco metabox slide and lock for security. 6 Providing and Placing in position High Back Chair. The seat shall be made up of 1.2 plus /-0.1 cm thk hot pressed plywood. The Back shall be made up of injection moulded glass filled nylon and upholstered using Micro mesh fabric with high tenacity yarn with 28 density foam Sandwich in lumbar area. SEAT SIZE shall be 47.0 cm. (W) x 51.5 cm (D) and BACK SIZE shall be 45.0 cm. ”(W) x 65.3 cm. (H). The HR polyurethane seat foam shall moulded with density 45 plus /-2 kg/m` and hardness 16plus2 kgf as per IS:7888 for 25% compression. The adjustable armrest shall be designed with the folIowingfeatures: • Up-Down adjustment— 8 steps (8.0 plus 0.Scm range), • Height adjustable armrest structure which is Powder Coated and fitted with an armrest top, • Fixed Armrest Top is PU moulded over metal insert. The adjustable tilting mechanism shall be designed with the following features: • 360° revolving type, • Single point control, • Front-pivot for tilt with feet resting on ground ensuring more comfort, • Tilt tension adjustment, • 4-position locking with anti shock feature, • Seat/back tilting ratio of 1:2. The Neckrest assembly consist of polypropylène pad with moulded polyurethane foam and covered with polyester fabric. Neckrest shall be fixed to Back Assembly through Neckrest connector. Neckrest assembly shall have height adjustment of 4.2plus0 5 cm and rotation adjustment of overall 76 plus /- 2 degree. The complète neckrest assembly shall be retro fit to the main chair. The pneumatic height adjustment shall have an adjustment Stroke of 10.0 plus /-0.3 cm. The pedestal shall be injection moulded in black 33% glass-filled Nylons and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 66.1 plus /-0.5 cm. (76.1 plus /-1.0 cm. with castors). The Coat Hanger shall be made up of injection moulded glass filled nylon. The Coat hanger shall be retro fit and is fixed to the back assembly. The twin wheel castors shall be injection moulded in black Nylon. 7 Providing and Placing in position Table for Doctor. Overall size of the Table shall be 1350 W mm x 600 D mm x 750 H mm. The top and modesty panel shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Table top shall be provided with Gromet on work surface for wire management. The understructure shall be made of 25 mm thick Pre-laminated twin board of E1-P2 grade, edge banded with matching 2 mm thick PVC lipping. Hinge Doors shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Handle shall be provided for ease of opening. Storage shall be provided with cam lock for security. 8 Providing and Placing in position Reception Chair. The seat assembly shall be made up of 1.2 ±0.1cm. thick hot-pressed plywood and shall be upholstered with fabric upholstery covers and moulded Polyurethane foam. The dimensions of seat shall be 47.0 cm. (W) x 48.0 cm. (D). The back asembly shall be made of powder coated (DFT 40-60 microns) tubular frame of dia 2.54 ±0.03cm.x 0.2±0.016cm thk.MS ERW tube designed with contoured lumbar support for extra comfort. The back shall be upholstered using Net fabric with high tenacity yarn. The dimensions of back shall be 46.5 cm (W) x 60.5 cm (H). The HR polyurethanefoam shall be moulded with density =45 plus /-2 kg/m3 and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The one-piece armrests shall be injection moulded from black Co-polymer Polypropylene. The mechanism shall be designed with 360° revolving type, 17±2° maximum tilt m pivot at centre, Upright position locking., Tilt tension adjustment. The pneumatic height adjustment shall has an adjustment stroke of 11.0 ±0.3cm. The bellow shall be 3 piece telescopic type and injection moulded in Black Polypropylene. The pedestal shall be injection moulded in black 33% glass-filled Nylon66 and fitted with 5 nos. twin wheel castors. The pedestal is 66.3 ±0.5cm.pitch-center dia. (76.3 ±1.0cm with castors). The twin wheel castors shall be injection moulded in Black Nylon. Overall Dimensions of Chair shall be Seat Height - min 43.3 to max 54.3cm, Height - min89.5 to max 100.5cm, Width and Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm. 9 Providing and Placing in position Visitors Chair. The cushioned seat assembly shall be made of injection molded plastic inner and outer. Plastic inner shall be upholstered with foam laminate fabric and moulded high resiliance polyurethane foam of density 45 plus /-2 per cubic metre and hardness load of 16 plus /-2 Kgf. Seat size shall be 46 cm W x 48 cm D. Thecushioned back shall be made of PU foam with insitu molded MS ERW round tube of size 1.9 plus /-0.03 x 0.16 plus /-0.0128 cm. it shall be upholstered with foam laminate fabric. Back size shall be 46.6 cm W x 59.6 cm H. The powder coated tubular frame shall be cantilever type and shall be made of 2.54 plus /-0.03 x 0.2 plus /-0.016 cm thick MS ERW tube. The back shall be connected to the frame through powder coated high pressure die cast connector piece. 10 Providig and Placing in poition Waiting Chair. The seat shell shall be a welded assembly ofseat,back and side frame. The seat and back shall be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They shall be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel. The welded assembly shall be powder coated ( DFT 40-60 microns). The seat shall has a front water fall edge to provide popliteal clearance for comfortable seating. It also shall has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flatsurfaces of seat and back shall aids in easy maintenance. The dimensions of seat shall be 47.8 cm (W) x 44.6 cm (D) and of back shall be 41.6 cm (W) x 23. cm (H). Understructure assembly shall consists of connecting beam and leg assembly made of M.S.E.R.W. oblong tube of size 7.5±0.03cm x5.0±0.03cm x 0.02±0.016cm thk.The welded structure assembly shall be powder coated (DFT 40-60 microns ).The leg assembly shall be fitted with shoes and levellers in Nylon. The leg structure shall be designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fiited to leg assembly shall help in aligning the structure for back to back arrangements. Levelers should take care of uneven flooring .Connecting beam shall be fitted with snap locking end cap.It also aids in side-by-side understructure alignment. Armrest assembly shall consists of armrest frame and armrest pad. The armrest frame shall be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it shall be powder coated (DFT 40-60 microns). Armrest pad shall be injection molded in Nylonand shall be fitted onto the armrest frame. Overall Dimensions shall beSeat Height - 44.1 cm, Height - 78.5 cm, Width and Depth of Chair as measured from pedestal - Width-169.5cm and Depth-63.8 cm. 11 Providing and Placing in position Main Table. Overall size of the table shall be 1500 W mm x 1500 D mm x 750 H mm. Worktop shall be made of Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Access Flap provided on work surface for wire management. Side table shall be Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Modesty Panel shall be made of 18mm Thick Pre-laminated twin board (PLT) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Cube legs shall be fabricated from MS ERW Tube of 50 mm x 25 mm x 1.2mm thick and 40 mm x 40 mm x 1.2 mm thick (as per IS: 7138). At the top surface of leg, support brackets of 3 mm thick HR (as per IS: 2062) shall be welded for fixing worktop. These shall be welded together by argo shield welding. This welded structure shall be coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert shall be fixed, on to which a straight M8 leveler fitted which allows for adjustment of the height upto 50mm. Cross Members shall be made from 50mm X 25mm X 1.2mm thick ERW tube (as per IS:7138). These shall be coated with 50 micron epoxy polyester coating. Cross Members shall be assembled by friction fit PDC joinery and grub screws. There shall always two cross members for one table. Soft closing access flap shall be used. Provision for standard size of 8 module electrical shall be offered. Access flap shall be made from Aluminum extrusion, PDC parts made from Aluminum Alloy and plastic parts are made from Nylon 6 and wire brush with nylon bristles. Power box made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 Module cutout provision). This shall be fixed with worktop along the depth at Access Flap position. Hinge Door Unit shall be made of 18mm Thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Door shall be fixed with slide on hinges and handle is provided for ease of opening. Drawer shall be provided with ebco metabox slide and lock for security. 12 Providing and Placing in position Main Chair. The cushioned seat assembly shall be consisting of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyster fabric. The cushioned back assembly shall be consisting of back inner moulded in Poly-propylene in-situ moulded with polyurethane and upholstered with high stretch knittedpolyster fabric. The back size shall be 45.5 cm x 53 cm H and the seat size shall be 48.5 cm W x 49.0 cm D. The hig hresiliance polyurethane foam used in the seat and back cushion shall be moulded in density 45 plus /- 2 kg/m³ and hardness load shall be 16 plus /- 2 kgf for 25% compression. The seat and back shall be firmly connected to the frame and shall be cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need of complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with back movement during posture changes. The `S` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass -filled poly-amideform the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 positions tilt limit feature which is inbuilt in seat base and the tension shall be user weight dependent. The armrset assembly shall be made of housing sliding over the armrest struture, both moulded in glass-filled polyamide. The height djustment feature shall be button operated having adjustment stroke of 6.6±0.5 cm. The armrest top shall be made of integral skin PU moulded over plastic inner moulded in glass filled polyamide. The seat height can be adjusted with the pneumatic gas-lift having an adjustment stroke of 9.2 plus /- 0.3 cm. The pedestal shall be injection moulded in glass-filled poly-amide and fitted 5 nos. of twin wheel castors The pedestal shall be 66plus /- 0.5 cm pitch center dia. and 76plus /- 1 cm with castors. 5 nos. of twin wheel castors shall be injection moulded in poly-amide having 5.0plus /- 0.1 cm wheel diameter and assembled with pedestal. 13 Providing and Placing in position Patient Stool. Overall Dimension: Overall Sizes Diagonal LegDia 538 mmH470 min-655maxTop plate should made of SS 202 made sheet with spin section of thickness 1mm and should be non corrosive. It should have a diameter of 305mm,seat base should made of MS ring and rectangular tube.EN8 Screw having dia of 22 mm should be used for height adjustment of the seat base.The round hub should be made of MS ERW tube having dia of 38mm and thickness 2 mm.The Hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.The understructure should consist of 4 legs made up ofMS ERW tube of diameter 25.4 mm and 1.6mm thick. The press formed pipe leg should give a round and clean look. All the legs should be provided with 4 nos of Nylon-6 bush.All metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coatingto fulfill the requirements for bacterial protection against at least 2 commonly found bacteria in Hospital environment [Gram positive and Gram Negative].Safe working load must be 135kg. 14 Providing and Placing in position Examination Table. Overall size of the table shall be 1830 mm L x600 mm D x 850 mm H. The examination table shall be made of sturdy structure and shall have a ratchet mechanism for tilting the backrest. Leg frame and intermediate frame shall be made of 30x30 section 1.6 mm thick M.S. ERW Tube. Nylon 6 leg shoe shall be provided to avoid wear and tear of the floor. Lying surface shall be made of 1.2 mm thick M.S. ERW Tube. Ratchet shall be made of 5 mm thick M.S. ERW tube and shall provide back tilt at 0º, 15º and 30º asjustment positions. Table shall be epoxy polyxter powder coated and shall have a maximum load bearing capacity of 135 kgs. It shall be provided with 30 mm thick mattress. Providing and Placing in position Single Step Stool. Overall size of the stool shall be 485 W mm x 355 D mm x 210 H mm. It shall be a sturdy stool for supporting patients while accessing the examination table. Understructure frame shall consist of 4 MS 1.2 mm thick Vertical tubes of 19mm Dia, 3 horizontal tubes at the bottom and 3 tubes at the top to support the sheet metal top. Stool top shall be made of 2 mm thick MS sheet for standing purpose. 3 Nos. of 4 mm thick aluminium extrusions strips shall be placed on the sheet metal top for getting a good grip while climbing. Max load bearing capacity shall be 135 Kgs. 15 Providing and Placing in position Plain Almirah. Overall size of the Almirah shall be 916 mm (W) x 486 mm (D) x 1980 mm (H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. It should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It shall have 4 no.s full shelves. A4 size box file(85 W x 285 D x 345 H mm) can be stored vertically on three shelves and the clear space above fourth shelf is 240mm. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns ( plus /- 10). There shall be 5 loading levels in the almirah. 16 Providing and Placing in position Modular Storage Unit. Overall size of the unit shall be 1800 W mm x 450 D mm x 1950 H mm. It shall be aesthetically appealing completely knock down construction. The add-on units are stack widthwise to form arow of storage. Legs fitted with screw type leveler. It shall be made from combination of Top panel(0.5mm CRCA), side panel(0.5mm CRCA), Bottom panel(0.5mm CRCA) Back panel(0.5mm CRCA), Top Bottom stiffener(1.2mm CRCA) and End Cover(0.5mm CRCA). Shelves shall be a 12 bend panel made of 0.7mm Thick CRCA (D Grade, IS-513)Each shelf has max Load Capacity of 30kg UDL with 4 Nos. of fixed shelves. A4 size Box file (85Wx340Hx285D) can be stored vertically on all loading levels. Doors shall be made of 0.6mm Thick CRCA (D Grade, IS-513) with Soft closing Hinges. Handles shall be Asthetically appealing handle made of Aluminum. It shall be having 3 Way locking provision, with Click action mechanism, with Key removable in locked and unlocked positions. Zinc alloy die cast housing. The unit shall be Epoxy Polyester Powder coated to the thickness of 50 microns ( plus /-10 micron). 17 Providing and placing of panel and tile based modular workstations which are GRIHA compliant and as per BIFMA standards, with partition thickness of 50 mm thick including powder coated aluminium trims and supported on Legs for better air circulation and helps in keeping floor clean. The product should be complete and as per apprroved sample and as per the direction of Engineer-In-charge. Panels Construction - Each panel consists of Vertical extrusions 2Nos and Horizontal extrusions made of 1.2mm thick aluminium with duly powder coated at every division of tile/block. Each panel have Bottom frame fabricated for 50 mm panel comprises of L-channels made of 2mm thick CRCA steel (IS: 513), formed plates of 3mm thick HR steel (IS: 2062) and ERW steel tube of size 35x15x1.6mm thick in oval cross section (IS: 7138) welded together. The complete bottom frame shall be powder coated with an average of 50-60 microns thickness of epoxy powder coating. The Bottom Frame is bolted with the Upright verticals. Each Panel is provided with 2Nos Legs of height 120mm are fixed at the bottom frame of the panel. Legs are fabricated by CO2 welded MS Tube of section 38mm x 25mm (IS: 7138 ERW Tube, 38mm x 25mm x 16bg) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5mm HR) over which an M8 Leveler is fitted which allows for adjustment of the height by 50mm. It will be coated with 45-50micron thickness of epoxy powder coating. Each Panel consists of 2Nos Intermediate blocks. In a 52.4mm Thick panel intermediate block shall comprise of 38mm thick paper honeycomb with 3mm MDF on each sides and 0.6mm decorative laminate on both sides. Particle board framing shall be used n outer boundary of these blocks as well as intermediately at certain locations forming conduit for passing cables. These blocks will be located in the middle bands of the panels made out of a composite construction of MDF and paper honeycomb. Each Panel consist of TOP TILES/SPLIT TILES. These tiles shall be slide in to the panels from top before fixing the top horizontal. These tiles shall be supported from top and bottom side with clips made from PP co polymer fitted in horizontal extrusion. In case of split tiles it shall be offered in Fabric magnetic tiles, Whiteboard tiles. Each Panel consists a BOTTOM TILE. These bottom tiles shall be press fitted on to the assembly frame of the panel with the help of snap on clips made of nylon-66 and support clips made from PP polymer.All partitions and side panels have levelling screws for adjustment in case of Uneven floor to take care ofplus /- 40 mm of uneven flooring.`Tile Finishes :a FABRIC MAGNETIC TILES: Fabric magnetic tiles shall be fabric upholstered metal tiles in 0.6 mm thick G.I. Grade O as per IS: 277. The fabrics shall be upholstered with adhesives.• FABRIC TACK TILES: Fabric tackable tiles shall be upholstered metal tiles in 0.6mm thick G.I. grade O as per IS: 277, with P.E. foam in the tile for tackablity.The fabric shall be upholstered with adhesives.• WHITE BOARD TILES : White board tiles shall be made of 8.0 mm thick particle board conforming to IS: 12823 laminated with 0.6mm thick white glossy high pressure laminate on outer side and 0.6mm backing laminate on inner surface and will behaving all its edges with minimum 0.5 mm thick PVC edging. `End/Intermediate Panels :It is a 22.8mm Thick panel used at the ends and as a intermediate panle between 2 adjacent workstations. It is conncted to the main panel using screws and provided with trims on the outer edges.`Aluminium Trims : The top trims and end trims for 52.4 mm shall be made from aluminum extrusion. All kinds of extrusions for 52.4mm shall have average wall thickness of 1.2 mm and having finish of powder coating. Top trim in 52.4mm thick panel shall be press fitted on the horizontal extrusion, it shall be slide fitted with the help of top trim connector made from PP copolymer 3530 grade.End trim for 52.4mm thick panel shall be slide fitted with the help of end trim connector made from 2.0mm thick M.S. CRCA Grade D as per IS: 513. End trim for 22.8 mm thick panel shall slide with the help of end trim connector made from nylon-66.``Wire Management - Wires shall be taken into the system through cable ducts from the junction boxes and it is carried upto the panels through concealed conduits inside the blocks. Wires runs through the system from Bottom tile and extended to the top at various locations by the help of 2 nos. vertical Cable Ducts in each panels. Cable duct shall be made from 0.8 mm thick M.S. CRCA Grade D as per IS: 513 - 1994. It is constructed with two parts, one is body and another is cover. It holds the cables and gives aesthetic appearance by covering all cables entry, which are moving upward to the panels. Size of Cable duct is 107mm W X 154 mm H X 21 mm D.`Legs - Metal powder coated legs at the end. System shall also have 120 mm high powder coated standalone panel legs to give the system an elevated look. Single side legs are fabricated by CO2 welded MS Tube of section 38 mm x 25 mm (IS: 7138 ERW Tube, 38 mm x 25 mm x 16bg) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5 mm HR) over which an M8 Leveler is fittedWorksurface : Worktop shall be made out of 25mm thick prelaminated particle board. All the open edges of work surface shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. The work surface shall be provided with circular cut out of Dia.65mm as per the requirement, for passing of wires. These cut outs shall be provided with ABS covers. Worksurfaces are fitted to the panels by worksurface brackets. Brackets are made of 2.0mm thick CRCA grade D steel as per IS : 513. Brackets are slide in between end trim and vertical extrusions.Mobile Drawer : Mobile Drawer Unit having 3 Drawers Unit having flat metal front and top with Central locking. The Drawer Unit consistes of 2Box and 1File Drawers. The Overall size of the Drawer Units is 450mm(W) X 435mm(D) X 646mm(H). Construction and Material of Drawer Unit : Welded Assembled of 0.8 thick CRCA for Body Shell, Drawer Front and tray, Front Side Stiffener, Rear Side Stiffener and Bottom, 1.2 thick CRCA Top Stiffener and Bottom stiffener. Drawer Fronts and Metal Front Straight Edge. All Drawers with Double extension precision ball slide shall be provided. For Drawer pulling, side wise tapered recess provided in shell behind Drawer Fronts. Locking:10 lever Cam Lock and Central Right Hand locking with actuator and lock channel mechanism. Top Panel : 0.8 Thick Metal Straight Edge Top. Castors : Swiveling non-lockable 4Nos Castors mounted below the body shell. The Total drawer unit is finished with Epoxy Polyester Powder coated to the thickness of 50 microns ( plus /-10).Key Board Pullout Tray : Supplying and Fixing of sliding computer key board tray of 480mm (L) X 280mm (D) X 40mm(H) made out of CRCA steel as per IS : 513 made of 0.9mm thick powder coated with sliding channels and other fixing fittings. It should also have a sliding system for accomodating mouse.CPU Trolley :Supplying and Fixing of CPU Trolley of Size - 345mm(W) x 226(D) x 180mm(H) is made of 1.0 mm thick MS CRCA Sheet and Side support is made of 0.8 mm thick MS CRCA Sheet. It consists of 4Nos Non-lockable twin wheel castors made of injection moulded in Black Nylon.Recta - 1200 W mm x 600 D mm x 1200 H mm 18 Providing and Placing in position 2 Dr. Locker for Students. Overall size of the unit shall be 370 mm (W) x 450 mm (D) x 1900 mm(H). It shall be made from combination of Top panel(0.5mm CRCA), side panel(0.5mm CRCA), Bottom panel(0.5mm CRCA) Back panel(0.5mm CRCA), Top Bottom stiffener (1.2mm CRCA) and End Cover(0.5mm CRCA). Shelves shall be a 12 bend panel made of 0.7mm Thick CRCA (D Grade, IS-513). Locking shall be cam lock with 3 way locking provision, with click action mechanism and shall have zinc alloy die cast housing. 19 Providng and Placing in position Optimisers. Size: Overall Dimensions of a body shall be 1200 mm (W) x 400 mm (D) x 2000 mm (H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel. Eachconfiguration have following type of blocks – Single Static (SS), Single Last (SL),Twin Mobile(TM). Finish: Finish shall be Epoxy polyester powder coated thickness of 40 microns. Construction: Shelf construction shall be made from CRCA steel 0.8 mm. Uniformly distributed load capacity of 100 Kg. Undercarriage: Undercarriage shall have construction in welded frame made of HR sheet 3 mm thick. Movement: The Movements shall be Push-Pull / Drive Type configuration. Locking: Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is placed at suitable height .The ‘sprocket-chain’ arrangement is covered by a 1 mm thk. CRCA sheet Drive Unit Cover with dimensions 1202mm x 398mm x 87mm and is fixed onto the side of the body. Fixed unit (SD) does not have the Handle. Each units shall have Locking Knob for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts and bolts are galvanized / blackodized / Zn Plated.Also total no. of loading levels per understructure shall be 15 for SD3. Label holder: It is an aluminium extrusion of length 396mm for LD/SD and 796mm for TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394mm for LD/SD and 794mm for TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. Rail Pair: It consists of ‘C’ section 2 mm thk HR sheet and Square 25.4mm X 2mm thk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug and screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800mm, 1600mm and 2400mm. 20 Providing and Placing in position 1$ Seater Meeting Table. Overall size of the Table shall be 3000 W mm x 1150 D mm x 740 H mm. Top shall be made of 25 mm thick Pre-laminated twin board, edge banded with matching PVC edge lipping. Access panel shall be provided with soft closing hinges. The understructure shall consist of 25 mm thick * 18 mm thick pre-laminated twin board, edge banded with 2 mm thick matching lipping. Anodised aluminium alloy 63400 - WP profile is added at bottom edges for improving the aesthetics. A wire raiser made of 0.8 mm thick CRCA shall be provided. It shall be epoxy polyster powder coatedc(DFT 40-60 microns) for flow of wires and cables. 21 Providing and Placing in position Meeting Chair. The seat shall be made up of 1.2 ±0.1cm thick hot pressed plywood. The back is made up of injection moulded glass filled nylon and upholstered using net fabric with high tenacity yam. The dimensions of seat should be 47.0cm(W) x 51.5(D) and that of back should be 45.0cm(W) x 65.3cm(H). The moulded polyurethane foam shall be ofdensity 55 plus /-2kg/m ³, and hardness load 16 plus /-2kgf as per IS:7888 for 25% compression. The armrests have up and down adjustment of 8.5 plus /-0.5 cm with top having integrated layer of Thermoplastic Elastomer(TPE). The lumbar support consists of polypropylene pad with moulded polyurethane foam covered with polyster fabric. The lumbar pad has adjustment of 8.0 plus /-0.5 cm. The mechanism of the chair shall have following features : 360° revolving type, Single point control, Tilt tension adjustment, 4 position locking with antishock feature, seat back tilt ratio 1:2, front pivot for tilt with feet resting on ground ensuring more comfort. The chair shall be provided with pneumatic height adjustment which shall have stroke of 10.0plus /- 0.3 cm. The pedestial shall be injection moulded in black 33% glass-filled Nylon-66. It shall be fitted with 5 nos twin wheel castor. The size of the pedestal shall be 66.1 plus /- 0.5 cm pitch-centre-dia (76.1plus /- 1.0 cm with castors). The twin wheel castors shall be made of Nylon injection moulded in black Nylon.Overall dimensions of Chair shall be, Width of Chair - 76.1cm, Depth of Chair - 76.1 cm as measured from pedestal below. Height of back from ground - min 98.0 to max 108.0cm. Seat height - min 44.0 to max 54.0cm. 22 Providing and Placing in position Canteen Table. Overall size of 1180 W mm x 1580 D mm x 750 H mm.Top shall be of Stainless Steel brushed with PLBinsert for Durability. Easy to maintain hygiene. The Understructure shall be made of 50.8 mmx 50.8 mm 1.2 mm thick powder coatedERW tubes at base which are welded and fixed to the Top with screws.Tubular stiffeners that are provided between the two vertical frames. The tubes shall be closed with plastic cap. The seats are offered in SS round stool types. Level adjustment shall be provided to take care of unevenness in floor. 23 Providing and Placing in position 3 Seater Sofa for Waiting Room. The side frame assembly shall be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. It shall be made of 0 3.81 ±0.03cm. x 0.2±0.016cm. thick cmx0.l6cm and black powder coated (DFT 40-60 microns). The ends shall be fitted with ABS moulded end caps. It shall be the connecting beam assy. which holds the two side frames to each other.2 nostie members shall be used to connect the side frames. The tie-member shall be of dia 3.81 ±0.03cm x 02±0.016cm. thick cm x 0.16cm and black powder coated (DFT 40-60 microns ). The seat/back assemblies shall be mounted on one of the tie-member which shall has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5±0.1cm. thk 5.5 ±0.1cm Long MS. Std. angles welded to mount the seat and back. The seat rest assembly shall be consists of a fabricated inner-frame assembly insitu-moulded High Resilience (HR) Polyurethane foam having density = 45plus /-2 Kg/cm3 with Hardness load=25±2kgf as per lS:7888 for 25%compression of the foam. The complete moulded seat rest assembly shall be covered with a replaceable fabric upholstery cover. The dimensions of seat shall be: 52.0cm. (W) X 50.0cm. (D) X 6.0cm. (T). The backrest assembly shall be flexing type and consists of a fabricated inner-frame assembly insitu-moulded with High Resilience (HR) Polyurethane foam having density = 45plus /- 2 Kg/cm3 with Hardness load 14± 2 kgf as per lS:7888 for 25% compression of the foam. The complete moulded backrest assembly shall be covered with a replaceable fabric upholstery cover. The size of the back shall be 52.0cm. (W) X 59.0cm. (H) X 6.0cm. (T) The adj. glide shall be injection moulded in black Nylon and fitted to the front end of side frame assembly along with ABS moulded adj. Glide base to take care or unleveled floor surface. Overall Dimensions of Chair shall be Seat Height - 43.5 cm, Height - 78.5cm, Width and Depth of Chair as measured from pedestal - Width-164.0cm and Depth-70.0 cm. 24 Providing and Placing in position Centre Table. The top shall be made of whichshall be 12 plus /-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shallbe a welded assembly made in SS202 grade having dia. 12 plus /-0.04 as per IS:1762. overall dimensions oftable shall be Width of table= 112.0 cm, Depth=60.0 cm, height=35.1 cm. 25 Providing and Placing in position Corner Table. The top shall be made of glass which shall be 12 plus /-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shallbe a welded assembly made in SS202 grade having dia. 12 plus /-0.04 as per IS:1762.overall dimensions oftable shall be Width of table= 60.0 cm, Depth=60.0 cm, height=35.1 cm. 26 Providing and Placing in position Table for HOD / Incharge. Overall size of the Table shall be 1800 W x 900 D x 750 H and ERU 1200 W x 500 D x 750 H. The table is made of 25 mm thick MDF – one side pre-laminate board confirming to IS-14587:1998 with 0.4 mm PVC membrane pressed on to top. Soft closing access flap within-build power box are provided on work surface for wire management. The ERU top is made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The modesty panel is made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The understructure is made of 25 mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2 mm thick PVC lipping. The pedestal is made of 25 mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2 mm thick PVC lipping. Drawer fronts made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 mm PVC membrane pressed on to top pedestal construction is BOX-BOX-FILE type which uses powder coated 400 MM long metal Panel Drawer Slides. Drawer extension is 325 MM. Drawers have a soft closing and anti slam mechanism. Handles are provided for ease of opening. Pedestals are provided with lock for security. 27 Providing and Placing 2 Seater Sofa for Incharge / HOD Cabin. Upper structure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-146.0 cm and Depth-92.0 cm. 28 Providing and Placing in position Office Table. Overall size of the table shall be 1200 W mm x 600 D mm x 750 H mm. The top and modesty panel shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Table top shall be provided with Gromet on work surface for wire management. The understructure shall be made of 25 mm thick Pre-laminated twin board of E1-P2 grade, edge banded with matching 2 mm thick PVC lipping. Hinge Doors shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Handle shall be provided for ease of opening. Storage shall be provided with cam lock for security. 29 `Providing and Placing in position Staff Chair. The cushioned seat assembly shall be consisting of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyster fabric. The cushioned back assembly shall be consisting of back inner moulded in Poly-propylene in-situ moulded with polyurethane and upholstered with high stretch knittedpolyster fabric. The back size shall be 45.5 cm x 53 cm H and the seat size shall be 48.5 cm W x 49.0 cm D. The hig hresiliance polyurethane foam used in the seat and back cushion shall be moulded in density 45 plus /- 2 kg/m³ and hardness load shall be 16 plus /- 2 kgf for 25% compression. The seat and back shall be firmly connected to the frame and shall be cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need of complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with back movement during posture changes. The ``S`` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass -filled poly-amideform the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 positions tilt limit feature which is inbuilt in seat base and the tension shall be user weight dependent. The armrset assembly shall be made of housing sliding over the armrest struture, both moulded in glass-filled polyamide. The height djustment feature shall be button operated having adjustment stroke of 6.6±0.5 cm. The armrest top shall be made of integral skin PU moulded over plastic inner moulded in glass filled polyamide. The seat height can be adjusted with the pneumatic gas-lift having an adjustment stroke of 9.2 plus /- 0.3 cm. The pedestal shall be injection moulded in glass-filled poly-amide and fitted 5 nos. of twin wheel castors The pedestal shall be 66plus /- 0.5 cm pitch center dia. and 76plus /- 1 cm with castors. 5 nos. of twin wheel castors shall be injection moulded in poly-amide having 5.0plus /- 0.1 cm wheel diameter and assembled with pedestal. 30 `Providing and Placing in position Conference Table. Overall size of the Table shall be 4200 W mm x 1500 D mm x 740 H mm. Top shall be made of 25 mm thick Pre-laminated twin board, edge banded with matching PVC edge lipping. Access panel shall be provided with soft closing hinges. The understructure shall consist of 25 mm thick * 18 mm thick pre-laminated twin board, edge banded with 2 mm thick matching lipping. Anodised aluminium alloy 63400 - WP profile is added at bottom edges for improving the aesthetics. Bottom cabinet with door shall be provided for flow of wires and cables. Cutout provision below access flap at 4 locations shall be provided. 31 `Providing and Placing in position High Back Conference Chair. The seat shall be made up of 1.2plus0.1cm thk. hot pressed plywood. The Back shall be made up of injection mou1ded glass filled nylon and upholstered using Mesh fabric with high tenacity yarn.SEAT SIZE : 47.0 cm. (W) x 51.5 cm (D) and BACK SIZE : 45.0 cm. (/V) x 65.3 cm. (H). The HR polyurethane seat foam shall be moulded with density 45 plus /-2 kg/m° and hardness 16plus2 kgf for 25% compression. The adjustable armrest shall be designed with the following features : Up-Down adjustment— 8 steps (8 0 plus 0.Scm range), Height adjustable armrest structure which is Powder Coated and fitted with an armrest top. The Lumbar support consists of polypropylene pad with moulded polyurethane foam and covered with polyester fabric. The Height of Lumbar pad can be adjusted through two projecting knobs provided on the rear side of the pa6. Lumbar pad has an adjustment of 8.0plus0.5 cm in height. The adjustable tilting mechanism shall be designed with the following features: 360° revolving type, Single point control, Front-pivot for tilt with feet resting on ground ensuring more comfort, Tilt tension adjustment, 4-position locking with anti-shock feature, Seat/back tilting ratio of 1:2. The Neckrest assembly consist of polypropylene pad with moulded polyurethane foam and covered with polyester fabric Neckrest is fixed to Back Assembly through Neckrest connector Neckrest assembly has height adjustment of4.2plus0.5 cm and rotation adjustment of overall76” plus2”. The complete neckrest assembly is retro fit to the main chair. The pneumatic height adjustment shall have an adjustment stroke oi 10.0plus0.3 cm. The pedestal is injection moulded in black 30% glass filled nylon and fitted with 5 nos. twin wheel castors. H=The pedestal pitch center dia is 66.1 plus 0.5 cm. The Coat Hanger is made up of injection moulded glass filled nylon. The coat hanger is retro fit and is fixed to the back assembly. The twin wheel castors are injection moulded in black Nylon. 32 `Poviding and Placing in position Medium Back Conference Chair. The seat shall be made up of 1.2plus0.1cm thk. hot pressed plywood. The Back shall be made up of injection mou1ded glass filled nylon and upholstered using Mesh fabric with high tenacity yarn.SEAT SIZE : 47.0 cm. (W) x 51.5 cm (D) and BACK SIZE : 45.0 cm. (/V) x 65.3 cm. (H). The HR polyurethane seat foam shall be moulded with density 45 plus /-2 kg/m° and hardness 16plus2 kgf for 25% compression. The adjustable armrest shall be designed with the following features : Up-Down adjustment— 8 steps (8 0 plus 0.Scm range), Height adjustable armrest structure which is Powder Coated and fitted with an armrest top. The Lumbar support consists of polypropylene pad with moulded polyurethane foam and covered with polyester fabric. The Height of Lumbar pad can be adjusted through two projecting knobs provided on the rear side of the pa6. Lumbar pad has an adjustment of 8.0plus0.5 cm in height. The adjustable tilting mechanism shall be designed with the following features: 360° revolving type, Single point control, Front-pivot for tilt with feet resting on ground ensuring more comfort, Tilt tension adjustment, 4-position locking with anti-shock feature, Seat/back tilting ratio of 1:2. The pedestal is injection moulded in black 30% glass filled nylon and fitted with 5 nos. twin wheel castors. H=The pedestal pitch center dia is 66.1 plus 0.5 cm. The twin wheel castors are injection moulded in black Nylon. 33 Providing and Placing in position Waiting Chair. The seat shell shall be a welded assembly ofseat,back and side frame. The seat and back shall be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They shall be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel. The welded assembly shall be powder coated ( DFT 40-60 microns). The seat shall has a front water fall edge to provide popliteal clearance for comfortable seating. It also shall has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flatsurfaces of seat and back shall aids in easy maintenance. The dimensions of seat shall be 47.8 cm (W) x 44.6 cm (D) and of back shall be 41.6 cm (W) x 23. cm (H). Understructure assembly shall consists of connecting beam and leg assembly made of M.S.E.R.W. oblong tube of size 7.5±0.03cm x5.0±0.03cm x 0.02±0.016cm thk.The welded structure assembly shall be powder coated (DFT 40-60 microns ).The leg assembly shall be fitted with shoes and levellers in Nylon. The leg structure shall be designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fiited to leg assembly shall help in aligning the structure for back to back arrangements. Levelers should take care of uneven flooring .Connecting beam shall be fitted with snap locking end cap.It also aids in side-by-side understructure alignment. Armrest assembly shall consists of armrest frame and armrest pad. The armrest frame shall be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it shall be powder coated (DFT 40-60 microns). Armrest pad shall be injection molded in Nylonand shall be fitted onto the armrest frame. Overall Dimensions shall beSeat Height - 44.1 cm, Height - 78.5 cm, Width and Depth of Chair as measured from pedestal - Width-169.5cm and Depth-63.8 cm. 34 `Providing and Placing in position 3 Seater Lounge Sofa. The side frame assembly shall be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. It shall be made of 0 3.81 ±0.03cm. x 0.2±0.016cm. thick cmx0.l6cm and black powder coated (DFT 40-60 microns). The ends shall be fitted with ABS moulded end caps. It shall be the connecting beam assy. which holds the two side frames to each other.2 nostie members shall be used to connect the side frames. The tie-member shall be of dia 3.81 ±0.03cm x 02±0.016cm. thick cm x 0.16cm and black powder coated (DFT 40-60 microns ). The seat/back assemblies shall be mounted on one of the tie-member which shall has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5±0.1cm. thk 5.5 ±0.1cm Long MS. Std. angles welded to mount the seat and back. The seat rest assembly shall be consists of a fabricated inner-frame assembly insitu-moulded High Resilience (HR) Polyurethane foam having density = 45plus /-2 Kg/cm3 with Hardness load=25±2kgf as per lS:7888 for 25%compression of the foam. The complete moulded seat rest assembly shall be covered with a replaceable fabric upholstery cover. The dimensions of seat shall be: 52.0cm. (W) X 50.0cm. (D) X 6.0cm. (T). The backrest assembly shall be flexing type and consists of a fabricated inner-frame assembly insitu-moulded with High Resilience (HR) Polyurethane foam having density = 45plus /- 2 Kg/cm3 with Hardness load 14± 2 kgf as per lS:7888 for 25% compression of the foam. The complete moulded backrest assembly shall be covered with a replaceable fabric upholstery cover. The size of the back shall be 52.0cm. (W) X 59.0cm. (H) X 6.0cm. (T) The adj. glide shall be injection moulded in black Nylon and fitted to the front end of side frame assembly along with ABS moulded adj. Glide base to take care or unleveled floor surface. Overall Dimensions of Chair shall be Seat Height - 43.5 cm, Height - 78.5cm, Width and Depth of Chair as measured from pedestal - Width-164.0cm and Depth-70.0 cm. 35 `Providing and Placing in position Stretcher. Overall dimension should be 2005 mm (L) x 666 mm (W) x 827 mm (H). It should be removable stretcher on trolley mointed on castors.. The trolley should be made of 31.75 mm and 25.5 mm dia 1.2 mm thick and 1.6 mm thick ERW tube. The casters should be 200 mm dia diagonal lockable castors. te stretcher understructure should be made of 25.4 mm dia 1.6 mm thick ERW tube and the top should be made of 1.2 mm thick CRCA sheet. The stretcher should have provision to mount IV pole at four corners. The product should be pre treated and powder coated with Epoxy polyster powder coating.The maximum load bearing capacity should be 135 kg. , 36 Providing and Placing in position Single Bed with understorage. Overall size of the bed shall be 2046 L mm x 919 D mm x 910 H mm with Bedstead height of 440 mm. Bed structure shall be made of metal frame of thickness 25mm square, Pipes in 1.2 mm thickness and MS Channel in 1.0 mm thickness. Partition Panel and plinths shall be made of 25 mm thickness Prelaminated Particle Board. Headboard, tailboard, side board, mattress panel and bottom panel shall be made of 18 mm thickness Prelaminated Particle Board. All exposed edges shall be banded with 0.8 mm thickness PVC edge banding. Overall size of understorage shall be 1491 L mm x 758 D mm x 265 H mm. Body panels shall be made of 18 mm hick prelaminated particle board. Drawer front shall be made of 18 mm thick prelaminated particle board. Drawer bottom shall be made of 9 mm thick prelaminated particle board. All exposed edges shall be banded with 0.8 mm thickness of edge banding. The bed shall be provided with 100 mm thick mattress. 37 Providing and Placing in position Bedside Table. Overall size of the Table shall be 460 W mm x 461 D mm x 510 H mm. Body panels shall be made of 18 mm hick prelaminated particle board. Drawer front shall be made of 18 mm thick prelaminated particle board. Drawer bottom shall be made of 9 mm thick prelaminated particle board. All exposed edges shall be banded with 0.8 mm thickness of edge banding. 38 Providing and Placing in position Study Table. Overall size of the Table shall be 900 W mm x 450 D mm x 750 H mm. Top panel shall be made of 18 mm thick Prelaminated Particle Board. All the exposed edges shall be edge banded with 2 mm thick PVC edge banding. Structure shall be made of metal frames made of M.S. 25 mm Square Pipes in 0.9 mm Thickness. Drawer assembly shall be made of drawer front made of 0.6mm CRCA sheet, drawer tray of 0.8mm CRCA sheet. 39 Providing and Placing in position Study Chair. The seat-back shall be made of blopw molded high-density polyethyleneand shall be fixed on the understructure assembly with the help of stainless steel pop rivets. Seat shall be made of bloe molded high-density polyethylene and shall be fixed on the understructre assembly. All the metal frames and cross-connectors of the understructre shall be made of Mild Steel ERW Tubes, 40 x 20 x 2 mm thick which shall be welded together. The welded structure and cross-connectors shall be coated with 45 microns thickness of epoxy polyster coating. Bag storage tray shall be made of mild steel rod forms a cage at bottom and shall be welded to the main structure. Plastic cap made of polypropylene shall be provided on the foot rest side tubes and back leg tubes adding more aesthetic value to the product. Overall size of the chair shall be 426 mm W x 420 mm D x 771 mm H. 40 Providing and Placing in position Dining Table. Overall size of the Table shall be 1500 W mm x 900 D mm x 760 H mm. The Table top shall be 19 mm thick and shall be made of MDF with Okume Veneer. It shall be 4 legged Table. Legs of the table shall be made of Solid Wood. The legs shall be L shaped. Finish of the table shall be Veneer. 41 Providing and placing in position Dining Chair. Overall size of the chair shall be 430 mm W x 565 mm D x 933 mm H. The understrcuture of the chair shall be made of solid wood and shall be PU coated. The seat and back shall be provided with cushion and shall be upholstered with PVC. The chair shall have sleek and contemporary design with high back support. 42 Providing and Placing in position Round Table. Overall size of the Table shall be 900 Dia x 720 H mm. The worktop shall be made of 18 mm thick MDF. The understructure shall consist of an inner tube assembly with Top Plate, for worktop mounting and an outer tube assembly with round bottom plate. The ineer and outer tube assemblies shall be telescopically connected. The top plate shall be made of 5 mm thick HR steel plates and the bottom plate shall be made of 8 mm thick HR Plate. The inner tube assembly shall be made of 82.5x2 thick round electric resistance welded tubes and 8 mm thick HR steel plates welded together using tungsten insert gas welding. The outer tube assembly shall be shall be made of 89x2.5 thick and round electric resistance welded tubes and 8 mm thick HR steel plates welded together using tungsten insert gas welding. The whole structure shall be epoxy polyster powder coated.(DFT 40-60 microns). 43 Providing and Placing in position Multipurpose Chair. The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The Tubular welded frame is made of made of 3.5±0.03cm x 1.5±0.03cm x 0.12±0.0128cm thk M.S. E.R.W.tube and welded connecting tube made of dia 2.22±0.03cm x 0.12±0.0128cm thk stainless steel 202 grade tube. The tubes are buff polished to give shiny finish. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. 44 Providing and Placing in position Sofa for Recreation Hall. Overall size of the Sofa shall be 1500 W mm x 705 D mm x 790 H mm. Seat understructure shall be made using combination of 12mm plywood vertical panels and pine-wood longitudnal members. 2 mm thick kraft-board shall be stapled on the front side for foam sticking surface. Seat shall be made with 100 mm PU slab stack foam pasted on the seat ply. 12 mm PU slab stack foam shall be pasted along the front and sides. The seat shall be upholstered in fabric. The sofa shall be provided with 2 nos. of 6A electrical sockets with individual switches. The electrical shall be safely housed in the box mounted on pinewood section within the seat and power shall be supplied through a 1.5 m AC cord with ceramic fuse. Back understructure shall be made using combination of 12mm plywood vertical panels and pine-wood longitudnal members. 2 mm thick MDF board shall be stapled on the front side for foam sticking surface. Back shall be made with 50mm PU Slab stack foam, while 12 mm PU slab stack foam shall be pasted along the back and sides. The back shall be upholstered with fabric. The legs shall be made using FSC-certified seasoned teakwood finished with a clear matt coat of PU lacquer. The seat and back are connected using bolts, washers and nuts. Legs shall be assembled using bolts, washers and drive-in T-nuts. 45 Providing and Placing in position Multipurpose Stool. Overall size of the stool shall be 450 W mm x 450 D mm x 453 H mm. The seat shall be made of synthetic leather upholstered on PU slab stack foam of 65( plus /-0.5cm). It shall be fitted on the upholstered wooden batten box by bolting from the inside. Holding plate shall be made of HR steel of 0.3 cm ( plus /- 0.2 cm) thickness. which shall be bolted to the upholstered seat assembly. Seat size shall be 42 cm W x 42 cm D. Casing of teh stool shall be made of 1 cm ( plus /-0/02cm) MS Rod. Casing shall be powder coated (DFT 40-60 microns). Also, casing shall be coated with nano coat to improve the abrasion resistance of teh surface. Casing size shall be 44 cm W x 44 cm D x 37.5 cm H. Side panel of wooden batten box shall be made of 0.9 cm ( plus /-0.05cm) plywood. The four corners of the batten box shall be made of solid wood which forms the radius. Bottom portion of the batten box shall be covered with 1.2 cm ( plus /- 0.05cm) rubberwood panel ehich shall be finished with clear matt coat of PU lacquer. Sied of wooden batten box shall be upholstered with synthetic leather with backing of slab stack foam of 0.6 cm. Upholstered wooden box can be flipped in the reverse way to use it as a desk surface by keeping it on the casing. Batten box size shall be 40 cm W x 40 cm D x 27.4 cm H. 46 Providing and Placing in position Single Bed. Overall size of the bed shall be 1980 W mm x 900 D mm x 400 H mm. Bed frame assembly shall be welding of side frame, inner slat. The side frame shall be made of rect. Tube of size 50.8 x 25.4 x 1.2 mm, welded to inner slat of sq. tube of size 19x1 mm MS ERW tube. Cladding shall be made of 12 mm thick ply. Head board and tail board shall be made of sq. pipe 38.1x1.2 mm and sq. pipe of size 25.4x1 mm thick MS ERW tube and support bracket of 3.2 mm thick ms sheet. 47 Providing and Placing in position Study Table. Overall size of the table shall be 1000 W mm x 480 D mm x 720 H mm. Table top shall be made of 15 mm thick MDF board. Drawer front and inner left and right of the drawer shall be made of 15 mm thick MDF board. Drawer bottom shall be made of 3 mm thick MDF board. Modesty and side panels of the table shall be made of 15 mm thick Particle Board. 0.18 mm thick PVC vaccum lamination shall be done on table top and drawer front, and 0.4 mm thick PVC vaccum lamination shall be done on modesty and side panels. 48 Providing and Placing in position Café Chair. The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The Tubular welded frame is made of made of 3.5±0.03cm x 1.5±0.03cm x 0.12±0.0128cm thk M.S. E.R.W.tube and welded connecting tube made of dia 2.22±0.03cm x 0.12±0.0128cm thk stainless steel 202 grade tube. The tubes are buff polished to give shiny finish. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. 49 Providing and Placing in position Café Table. Overall size of the Table shall be 2329 W mm x 1175 D mm x 750 H mm.Top shall be made of 25 mm thick( plus /-1mm) base material shall be 25 mm MDF board. On top PU painting of minimum 2H hardness with 75% glass as per color chart. Combination color graphics on the centre. Brown Laminate on bottom specially profiled edges for comfort. The Understructure shall be having bend pipe structure of MS powder coated. Pipe dia 38 mm, 2 mm thick and it shall be fitted with top by SS machine screws. Legs shall be of MS powder coated and 38 mm dia. pipe legs are fixed with inderstructure and table top. Glide shall be of Plastic fixed at the understructure to prevent the damage of table top during stacking. 50 Providing and Placing in position Table. Overall size of the table shall be 1500 W mm x 1500 D mm x 750 H mm. Worktop shall be made of Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Access Flap provided on work surface for wire management. Side table shall be Made of 25mm Thick Pre-laminated board (PLB) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Modesty Panel shall be made of 18mm Thick Pre-laminated twin board (PLT) of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Cube legs shall be fabricated from MS ERW Tube of 50 mm x 25 mm x 1.2mm thick and 40 mm x 40 mm x 1.2 mm thick (as per IS: 7138). At the top surface of leg, support brackets of 3 mm thick HR (as per IS: 2062) shall be welded for fixing worktop. These shall be welded together by argo shield welding. This welded structure shall be coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert shall be fixed, on to which a straight M8 leveler fitted which allows for adjustment of the height upto 50mm. Cross Members shall be made from 50mm X 25mm X 1.2mm thick ERW tube (as per IS:7138). These shall be coated with 50 micron epoxy polyester coating. Cross Members shall be assembled by friction fit PDC joinery and grub screws. There shall always two cross members for one table. Soft closing access flap shall be used. Provision for standard size of 8 module electrical shall be offered. Access flap shall be made from Aluminum extrusion, PDC parts made from Aluminum Alloy and plastic parts are made from Nylon 6 and wire brush with nylon bristles. Power box made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 Module cutout provision). This shall be fixed with worktop along the depth at Access Flap position. Hinge Door Unit shall be made of 18mm Thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Door shall be fixed with slide on hinges and handle is provided for ease of opening. Drawer shall be provided with ebco metabox slide and lock for security. 51 Providing and Placing in position High Back Chair for Warden. The cushioned seat assembly shall be consisting of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyster fabric. The cushioned back assembly shall be consisting of back inner moulded in Poly-propylene in-situ moulded with polyurethane and upholstered with high stretch knittedpolyster fabric. The back size shall be 45.5 cm x 53 cm H and the seat size shall be 48.5 cm W x 49.0 cm D. The hig hresiliance polyurethane foam used in the seat and back cushion shall be moulded in density 45 plus /- 2 kg/m³ and hardness load shall be 16 plus /- 2 kgf for 25% compression. The seat and back shall be firmly connected to the frame and shall be cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need of complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with back movement during posture changes. The `S` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass -filled poly-amideform the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 positions tilt limit feature which is inbuilt in seat base and the tension shall be user weight dependent. The armrset assembly shall be made of housing sliding over the armrest struture, both moulded in glass-filled polyamide. The height djustment feature shall be button operated having adjustment stroke of 6.6±0.5 cm. The armrest top shall be made of integral skin PU moulded over plastic inner moulded in glass filled polyamide. The seat height can be adjusted with the pneumatic gas-lift having an adjustment stroke of 9.2 plus /- 0.3 cm. The pedestal shall be injection moulded in glass-filled poly-amide and fitted 5 nos. of twin wheel castors The pedestal shall be 66plus /- 0.5 cm pitch center dia. and 76plus /- 1 cm with castors. 5 nos. of twin wheel castors shall be injection moulded in poly-amide having 5.0plus /- 0.1 cm wheel diameter and assembled with pedestal. 52 Providing and Placing in position 3 Seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-205.5 cm and Depth-92.0 cm. 53 Providing and Placing in position 1 Seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-86.0 cm and Depth-92.0 cm. 54 Providing and Placing in position Round Table. Overall size of the table shall be 1050 Dia. mm x 733 H mm.The Round Table Worktop shall be made up of 25 mm thick PLT. The Round Tableshall haveKnocked Down Understructure made from 8 mm HR plate with levellers and a vertical support tube of diameter 90 and 2 mm thickness . 55 Providing and Placing in position 3 Seater Lounge Sofa. The side frame assembly shall be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. It shall be made of 0 3.81 ±0.03cm. x 0.2±0.016cm. thick cmx0.l6cm and black powder coated (DFT 40-60 microns). The ends shall be fitted with ABS moulded end caps. It shall be the connecting beam assy. which holds the two side frames to each other.2 nostie members shall be used to connect the side frames. The tie-member shall be of dia 3.81 ±0.03cm x 02±0.016cm. thick cm x 0.16cm and black powder coated (DFT 40-60 microns ). The seat/back assemblies shall be mounted on one of the tie-member which shall has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5±0.1cm. thk 5.5 ±0.1cm Long MS. Std. angles welded to mount the seat and back. The seat rest assembly shall be consists of a fabricated inner-frame assembly insitu-moulded High Resilience (HR) Polyurethane foam having density = 45plus /-2 Kg/cm3 with Hardness load=25±2kgf as per lS:7888 for 25%compression of the foam. The complete moulded seat rest assembly shall be covered with a replaceable fabric upholstery cover. The dimensions of seat shall be: 52.0cm. (W) X 50.0cm. (D) X 6.0cm. (T). The backrest assembly shall be flexing type and consists of a fabricated inner-frame assembly insitu-moulded with High Resilience (HR) Polyurethane foam having density = 45plus /- 2 Kg/cm3 with Hardness load 14± 2 kgf as per lS:7888 for 25% compression of the foam. The complete moulded backrest assembly shall be covered with a replaceable fabric upholstery cover. The size of the back shall be 52.0cm. (W) X 59.0cm. (H) X 6.0cm. (T) The adj. glide shall be injection moulded in black Nylon and fitted to the front end of side frame assembly along with ABS moulded adj. Glide base to take care or unleveled floor surface. Overall Dimensions of Chair shall be Seat Height - 43.5 cm, Height - 78.5cm, Width and Depth of Chair as measured from pedestal - Width-164.0cm and Depth-70.0 cm. 56 Providing and Placing in position Dining Hall Chair. The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The Tubular welded frame is made of made of 3.5±0.03cm x 1.5±0.03cm x 0.12±0.0128cm thk M.S. E.R.W.tube and welded connecting tube made of dia 2.22±0.03cm x 0.12±0.0128cm thk stainless steel 202 grade tube. The tubes are buff polished to give shiny finish. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. An upholstery cover can be retro fitted on to seat and back. The seat cover is made from High abrasion resistance fabric with foam lamination and 2.5cm PU foam insert. The back cover is made from high abrasion resistance fabric with foam lamination and 0.1 cm PU foam insert. 57 `Providing and Placing in position High Back Chair for Warden. The cushioned seat assembly shall be consisting of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyster fabric. The cushioned back assembly shall be consisting of back inner moulded in Poly-propylene in-situ moulded with polyurethane and upholstered with high stretch knittedpolyster fabric. The back size shall be 45.5 cm x 53 cm H and the seat size shall be 48.5 cm W x 49.0 cm D. The hig hresiliance polyurethane foam used in the seat and back cushion shall be moulded in density 45 plus /- 2 kg/m³ and hardness load shall be 16 plus /- 2 kgf for 25% compression. The seat and back shall be firmly connected to the frame and shall be cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need of complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with back movement during posture changes. The ``S`` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass -filled poly-amideform the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 positions tilt limit feature which is inbuilt in seat base and the tension shall be user weight dependent. The armrset assembly shall be made of housing sliding over the armrest struture, both moulded in glass-filled polyamide. The height djustment feature shall be button operated having adjustment stroke of 6.6±0.5 cm. The armrest top shall be made of integral skin PU moulded over plastic inner moulded in glass filled polyamide. The seat height can be adjusted with the pneumatic gas-lift having an adjustment stroke of 9.2 plus /- 0.3 cm. The pedestal shall be injection moulded in glass-filled poly-amide and fitted 5 nos. of twin wheel castors The pedestal shall be 66plus /- 0.5 cm pitch center dia. and 76plus /- 1 cm with castors. 5 nos. of twin wheel castors shall be injection moulded in poly-amide having 5.0plus /- 0.1 cm wheel diameter and assembled with pedestal. 58 Providing and Placing in position 3 Seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-205.5 cm and Depth-92.0 cm. 59 Providing and Placing in position 3 Seater Lounge Sofa. The side frame assembly shall be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. It shall be made of 0 3.81 ±0.03cm. x 0.2±0.016cm. thick cmx0.l6cm and black powder coated (DFT 40-60 microns). The ends shall be fitted with ABS moulded end caps. It shall be the connecting beam assy. which holds the two side frames to each other.2 nostie members shall be used to connect the side frames. The tie-member shall be of dia 3.81 ±0.03cm x 02±0.016cm. thick cm x 0.16cm and black powder coated (DFT 40-60 microns ). The seat/back assemblies shall be mounted on one of the tie-member which shall has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5±0.1cm. thk 5.5 ±0.1cm Long MS. Std. angles welded to mount the seat and back. The seat rest assembly shall be consists of a fabricated inner-frame assembly insitu-moulded High Resilience (HR) Polyurethane foam having density = 45plus /-2 Kg/cm3 with Hardness load=25±2kgf as per lS:7888 for 25%compression of the foam. The complete moulded seat rest assembly shall be covered with a replaceable fabric upholstery cover. The dimensions of seat shall be: 52.0cm. (W) X 50.0cm. (D) X 6.0cm. (T). The backrest assembly shall be flexing type and consists of a fabricated inner-frame assembly insitu-moulded with High Resilience (HR) Polyurethane foam having density = 45plus /- 2 Kg/cm3 with Hardness load 14± 2 kgf as per lS:7888 for 25% compression of the foam. The complete moulded backrest assembly shall be covered with a replaceable fabric upholstery cover. The size of the back shall be 52.0cm. (W) X 59.0cm. (H) X 6.0cm. (T) The adj. glide shall be injection moulded in black Nylon and fitted to the front end of side frame assembly along with ABS moulded adj. Glide base to take care or unleveled floor surface. Overall Dimensions of Chair shall be Seat Height - 43.5 cm, Height - 78.5cm, Width and Depth of Chair as measured from pedestal - Width-164.0cm and Depth-70.0 cm. 60 Providing and Placing in position Office Table. Overall size of the table shall be 1200 W mm x 600 D mm x 750 H mm. The top and modesty panel shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Table top shall be provided with Gromet on work surface for wire management. The understructure shall be made of 25 mm thick Pre-laminated twin board of E1-P2 grade, edge banded with matching 2 mm thick PVC lipping. Hinge Doors shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, edge banded with 2 mm thick PVC lipping. Handle shall be provided for ease of opening. Storage shall be provided with cam lock for security. 61 `Providing and Placing in position Chair for Lecture Hall. The seat sub-assembly shall be made up of 1.2±0.1cm Thk Plywood, upholstered with polyester fabric over moulded foam and covered with an injection-moulded polypropylene outer cover. The seat can be manually tipped-up when not in use. The back sub-assembly shall be made up of injection-moulded glass filled polypropylene inner upholstered with polyester fabric over moulded foam and covered with an injection-moulded polypropylene outer cover. Both these sub-assemblies shall be fixed to the tubular structure. Back size : 46.3 W cm x 59 H cm. Seat size : 47 W cm x 49.5 D cm. The support structure shall be made of a U-bent Ø3.81±0.03cm x 0.2 ±0.016cm Thk M.S.E.R.W round tube and shall be supported using two Ø3.81±0.03cm x 0.2 ±0.016cm Thk M.S.E.R.W round tube at the bottom. The tip-up seat assembly shall be pivoted on a welded support assembly of a straight and bent tube of Ø2.22±0.03cm x 0.25 ±0.016cm Thk M.S.E.R.W round tube which shall be welded to the main U-Bent Leg. The Back assembly is mounted on a 3.15mm thick Armrest bracket using Screw. The frame structure shall be grouted using 3 Bolts on a 5mm thick base plate which shall be welded to the upper frame structure. Thebolts with base plate shall be enclosed using PP foundation bolt cover. The HR polyurethane foam shall be moulded with density = 45 ±2 kg/m³ and Hardness load for Seat 16 ± 2 kgf and Hardness load for back 14 ± 2 kgf for 25% compression. The armrest shall be made of Injection moulded PP compound. The Armrest shall be mounted on a 3.15mm thick HR sheet which shall be welded on the tubular frame. The desklet assembly shall be flip-up type and shall be supported by a welded assembly of extension tube and a bent support tube of 1.9 ±0.02cm dia x 0.2 ±0.016cm ThkM.S.E.R.W. tube. The PLT desklet top shall be PP edge moulded. Rubber Bangers shall be installed to prevent banging and scratch in the bottom part of desklet. The desklet can be adjusted by 50 mm in depth as per comfort and reach requirement. Steel components shall be epoxy polyester powder coated (DFT 40-60 microns). 62 Providing and Placing in posirion Desk Cum Bench for Lecture Halls. The top shall be made of 25mm thk PLB, legs shall be made of 2mm thk oval tube with 5mm thk HR bracket, Seat understructure shall be made of 5mm thk HRplus8mm thk ply and Modesty shall be made of 25mm thk pre laminted twin board. Seat support frame and side clads shall be made of 18mm thk plate. Legs shall be made of MS ERW tube section (IS7138) of size 75x25x2 mm thick oval tube with 5mm thk HR brackets and 2mm thick CRCA brackets welded on to the tubes. Assembly shall be powder coated with epoxy polyester. Legs height varies from 705mm to 1005mm in pitch of 50 as per layout. Sturdy anchoring by bolts on to base of 8mm thk plate for proper resting of leg. The shoes shall be made of bolts on to base of 8mm thk plate for resting of leg. The two side clads shall be made of 18mm thk plate with 0.8mm thk PVC lipping and on the outside covered with welded metal structure made of 2mm thk CRCApowder coated with epoxy polyster. The worktops shall be made of 25mm thk PLB. All edges of work surface shall be provided with machine pressed 2mm thick pvc edge band glued with hot melt glue. The seat shall have self closing mechanism which will operate by means of dead weight. Seat understructure shall be made from combination of welded fabricated structure of 5mm thk HR and 8mm thk ply with moulded PU foam of density 55kg/cu. mt on top which in turn shall be covered with stiched uplholstery made of leatherite. Seat assy shall be covered on both sides by means of seat cover made of pp. The seat back shall be made from combination of 8mm thk ply with moulded foam on top which in turn shall be covered with stitched upholstery made leatherite. The seat support frame shall be made from combination of MS ERW tube section of size 80x40x2.5 mm thk rectangular tube and MS ERW tube section of size 48x19.1x2 mm thk oval tube welded together. Assembly shall be powder coated with Epoxy polyester. Cap made of ultramid are provided from front to cover the oval tubes. The modesty shall be made of 25mm thk pre laminated twin board. All the edges of modesty shall be provided with machine pressed 2mm thk pvc edge band glue with hot melt glue. 63 Providing and Placing in position Main Table. Overall size of the table shall be 2350 mm (L) x 1150 mm (D) x 750 mm (H), Side Table 1200 mm (L) x 500 mm (D) x 750 mm (H) and integrated Pedestals 2Nos fixed type Drawer Units in each table set of size 470 mm (W) x 500 mm (D) x 725 mm (H) - one in Main table and one in Side Table. The Main Table and Side Table tops shall be made of 25mm thick MDF with bottom side pre-laminate confirming to IS-14587:1998 and 0.4mm PVC membrane pressed on to top. Soft closing access flap within-build power box are provided on work surface for wire management. The modesty panel shall be made of 25mm thick MDF - one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The understructure shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. The drawer unit shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. Drawer Units - Drawer fronts shall be made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Each drawer unit shall contain 3 drawers i.e. BoxplusBoxplusFile type which uses powder coated 400mm long metal Panel Drawer Slides. Drawer extension shall be 325mm. Drawers shall have a soft closing and anti slam mechanism. Chrome plated flat type handles shall be provided for ease of opening. Drawer units are provided with lock for security. 64 Providing and Placing in position Display Unit. Overall size of the Display Unit shall be 1800mm(L) x 500mm(D) x 1800mm(H). The Back unit shall comprises bottom sliding storage unit and top hollow storage spcae which are covered with top panels. The top panel of the back unit shall be made up of 25mm thick MDF one side pre-laminated board confirming to IS:14587:1998 with 0.4 mm PVC membrane pressed on top. Sliding door unit shall be made of made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Shutters have a soft closing and anti slam mechanism. Handles are provided for ease of opening. Storage is provided with lock for security. 65 Providing and Placing in position High Back Chair. The cushioned seats shall be made of injection moulded plastic outer and inner. Plastic inner shall be upholstered with pure leather and moulded high resiliance polyurethane foamof Density = 45±2 kg/m³, and hardness load 16±2 kgf as per IS:7888 for 25% of compression. Seat size shall be 47.6 cm W x 49.2 cm D. The back shall be cushioned and shall be made up of PU foam with insitu moulded MS ERW round tube of size 1.9±0.03 cm x 0.16±0.0128 cm, upholstered with pure leather. Back size shall be 47.5 cm W x 77 cm D. The armrest top shall be moulded from polurethane, and shall be upholstered with pure leather and mounted on ot a drop lift adjustable type tubular armrest support made up of Ø3.81±0.03 cm x 0.2±0.01 cm thick MS ERW tube having chrome plated finish. The armrest hieght shall be adjustable upto 6.5±0.5 cm in 5 steps. The adjustable tilting mechanism shall be designed with the following features : 360° revolving type, front-pivot for tilt with feet resting on ground and contionuous lumbar support ensuring more comfort, Tilt tension adjustment can be operated in seating position, 5-position tilt limiter giving options of variable tilt angle to the chair, seat/backtilting ratio 1:2, the mechanism housing is made up of aluminium black powder coated. Seat depth adjustment shall be integrated in the seat through a sliding mechanism. Seat depth adjustment range shall be 6.0±0.5 cm. Back frame shall be connected to the up/down mechanism housed in plastic T spine. It can be adjusted in the range of 7.4 ± 0.5 cm for the comfortable back support to suit individual need. the pneumatic height adjustment shall have an adjustment stroke of 10±0.3 cm. The pedestal shall be high pressure die cast polished aluminium and fitted with 5 nos. of twin wheel castors. The pedestal shall be 65.0±0.5 cm pitch centre dia. 5 nos. of twin wheel castors shall be injection moulded in plastic having 6.0±0.1 cm wheel diameter and assembled to pedestal. 66 Providing and Placing in position Vistors Chair. The cushioned seats shall be made of injection moulded plastic outer and inner. Plastic inner shall be upholstered with pure leather and moulded high resiliance polyurethane foamof Density = 45±2 kg/m³, and hardness load 16±2 kgf as per IS:7888 for 25% of compression. Seat size shall be 47.6 cm W x 49.2 cm D. The back shall be cushioned and shall be made up of PU foam with insitu moulded MS ERW round tube of size 1.9±0.03 cm x 0.16±0.0128 cm, upholstered with pure leather. Back size shall be 47.5 cm W x 77 cm D. The tubular frame shall be cantilever type and made of Ø2.54±0.03 cm x 0.2±0.016 cm thick SS 202 tube. The back shall be connected to the frame through chrome plated high pressure die cast connector piece. 67 Providing and Placing in position 3 seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-205.5 cm and Depth-92.0 cm. 68 Providing and Placing in position 2 seater sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-146.0 cm and Depth-92.0 cm. 69 Providing and Placing in position Center Table. The top shall be made of whichshall be 12 plus /-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shallbe a welded assembly made in SS202 grade having dia. 12 plus /-0.04 as per IS:1762. overall dimensions oftable shall be Width of table= 112.0 cm, Depth=60.0 cm, height=35.1 cm. 70 Providing and Placing in position Corner Table. The top shall be made of glass which shall be 12 plus /-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shallbe a welded assembly made in SS202 grade having dia. 12 plus /-0.04 as per IS:1762.overall dimensions oftable shall be Width of table= 60.0 cm, Depth=60.0 cm, height=35.1 cm. 71 Providing and Placing in position 1 Seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm.thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall beSeat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-86.0 cm and Depth-92.0 cm. 72 Providing and Placing in position Main Table. Overall size of the table shall be 2100 mm (L) x 1050 mm (D) x 750 mm (H), Side Table 1200 mm (L) x 500 mm (D) x 750 mm (H) and integrated Pedestals 2Nos fixed type Drawer Units in each table set of size 470 mm (W) x 500 mm (D) x 725 mm (H) - one in Main table and one in Side Table. The Main Table and Side Table tops shall be made of 25mm thick MDF with bottom side pre-laminate confirming to IS-14587:1998 and 0.4mm PVC membrane pressed on to top. Soft closing access flap within-build power box are provided on work surface for wire management. The modesty panel shall be made of 25mm thick MDF - one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The understructure shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. The drawer unit shall be made of 25mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2mm thick PVC lipping. Drawer Units - Drawer fronts shall be made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Each drawer unit shall contain 3 drawers i.e. BoxplusBoxplusFile type which uses powder coated 400mm long metal Panel Drawer Slides. Drawer extension shall be 325mm. Drawers shall have a soft closing and anti slam mechanism. Chrome plated flat type handles shall be provided for ease of opening. Drawer units are provided with lock for security. 73 Providing and Placing in position Display Unit. Overall size of the Display Unit shall be 1800mm(L) x 500mm(D) x 1100mm(H). The Back unit shall comprises bottom sliding storage unit and top hollow storage spcae which are covered with top panels. The top panel of the back unit shall be made up of 25mm thick MDF one side pre-laminated board confirming to IS:14587:1998 with 0.4 mm PVC membrane pressed on top. Sliding door unit shall be made of made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Shutters have a soft closing and anti slam mechanism. Handles are provided for ease of opening. Storage is provided with lock for security. 74 Providing and Placing in position High Back Chair. Overall size of 76.1 cm W x 76.1 cm D x 112.7 – 130.2 cm H x 43.1 – 53.1 cm Seat Height. The seat is cushioned seat made of injection molded plastic outer and inner. Plastic inner is upholstered with leatherette and molded high resilience polyurethane foam of density 45±2 kg/m³, and hardness load of 16±2 kgf as per IS:7888 for 25% compression. Seat Size is 47.0 W cm x 48.0 D cm. The back is cushioned made of PU foam with insitu molded M.S. ERW round tube of size 1.9±0.03cm x 0.16±0.0128cm, upholstered with leatherette. The back size is 47.7 W cm x 76.4 D cm. The armrest top is molded from polyurethane and mounted on to a drop lift adjustable type tubular armrest support made of Ø3.81±0.03cm x 0.2±0.01cm thick M.S. ERW tube having chrome plated finish. The armrest is height adjustable up to 6.5±0.5 cm in 5 steps. The adjustable tilting mechanism is designed with following features : 360° revolving type, front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort, tilt tension adjustment can be operated in seating position, 5-position tilt limiter giving option of variable tilt angle to the chair, Seat/back tilt ratio 1:2, The mechanism housing is made up of HPDC aluminium black powder coated. Seat depth adjustment is integrated in the seat through a sliding mechanism. Seat depth adjustment range is of 6.0±0.5cm. Back frame is connected to the up/down mechanism in plastic T spine. It can be adjusted in the range of 7.42±0.5 comfort the comfortable back support to suit individual need. The pneumatic height adjustment has an adjustment stroke of 10.0±0.3cm. The pedestal is high pressure die cast polished aluminium and fitted with 5 nos. of twin wheel castors. The pedestal is 65.0±0.5cm pitch centre dia. (75.0±1.0cm with castors). 5 nos. of twin wheel castors are injection molded in plastic having 6.0±0.1cm wheel diameter and assembled to pedestal. 75 Providing and Placing in position Visitors Chair. Overall size of 60.9 W m x 64.2 D cm x 98.2 H cm x 44.8 Seat Height cm. The seat is cushioned seat made of injection molded plastic outer and inner. Plastic inner is upholstered with leatherette and molded high resilience polyurethane foam of density 45±2 kg/m³, and hardness load of 16±2 kgf as per IS:7888 for 25% compression. Seat Size is 47.0 W cm x 48.0 D cm. The back is cushioned made of PU foam with insitu molded M.S. ERW round tube of size 1.9±0.03cm x 0.16±0.0128cm, upholstered with leatherette. The back size is 47.7 W cm x 76.4 D cm. The tubular frame is cantilever type and made of Ø2.54±0.03cm x 0.2±0.016 cm thick SS 202 tube. The back connected to frame through chrome plated high pressure die casted connector pipe. 76 Providing and Placing in position Main Chair. The seat shall be made up of 1.2 plus /-0.1 cm thk hot pressed plywood. The Back shall be made up of injection moulded glass filled nylon and upholstered using Micro mesh fabric with high tenacity yarn with 28 density foam Sandwich in lumbar area. SEAT SIZE shall be 47.0 cm. (W) x 51.5 cm (D) and BACK SIZE shall be 45.0 cm. ”(W) x 65.3 cm. (H). The HR polyurethane seat foam shall moulded with density 45 plus /-2 kg/m` and hardness 16plus2 kgf as per IS:7888 for 25% compression. The adjustable armrest shall be designed with the folIowingfeatures: • Up-Down adjustment— 8 steps (8.0 plus 0.Scm range), • Height adjustable armrest structure which is Powder Coated and fitted with an armrest top, • Fixed Armrest Top is PU moulded over metal insert. The adjustable tilting mechanism shall be designed with the following features: • 360° revolving type, • Single point control, • Front-pivot for tilt with feet resting on ground ensuring more comfort, • Tilt tension adjustment, • 4-position locking with anti shock feature, • Seat/back tilting ratio of 1:2. The Neckrest assembly consist of polypropylène pad with moulded polyurethane foam and covered with polyester fabric. Neckrest shall be fixed to Back Assembly through Neckrest connector. Neckrest assembly shall have height adjustment of 4.2plus0 5 cm and rotation adjustment of overall 76 plus /- 2 degree. The complète neckrest assembly shall be retro fit to the main chair. The pneumatic height adjustment shall have an adjustment Stroke of 10.0 plus /-0.3 cm. The pedestal shall be injection moulded in black 33% glass-filled Nylons and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 66.1 plus /-0.5 cm. (76.1 plus /-1.0 cm. with castors). The Coat Hanger shall be made up of injection moulded glass filled nylon. The Coat hanger shall be retro fit and is fixed to the back assembly. 77 Providing and Placing in position 3 Seater Sofa for Waiting Room. The side frame assembly shall be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. It shall be made of 0 3.81 ±0.03cm. x 0.2±0.016cm. thick cmx0.l6cm and black powder coated (DFT 40-60 microns). The ends shall be fitted with ABS moulded end caps. It shall be the connecting beam assy. which holds the two side frames to each other.2 nostie members shall be used to connect the side frames. The tie-member shall be of dia 3.81 ±0.03cm x 02±0.016cm. thick cm x 0.16cm and black powder coated (DFT 40-60 microns ). The seat/back assemblies shall be mounted on one of the tie-member which shall has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5±0.1cm. thk 5.5 ±0.1cm Long MS. Std. angles welded to mount the seat and back. The seat rest assembly shall be consists of a fabricated inner-frame assembly insitu-moulded High Resilience (HR) Polyurethane foam having density = 45plus /-2 Kg/cm3 with Hardness load=25±2kgf as per lS:7888 for 25%compression of the foam. The complete moulded seat rest assembly shall be covered with a replaceable fabric upholstery cover. The dimensions of seat shall be: 52.0cm. (W) X 50.0cm. (D) X 6.0cm. (T). The backrest assembly shall be flexing type and consists of a fabricated inner-frame assembly insitu-moulded with High Resilience (HR) Polyurethane foam having density = 45plus /- 2 Kg/cm3 with Hardness load 14± 2 kgf as per lS:7888 for 25% compression of the foam. The complete moulded backrest assembly shall be covered with a replaceable fabric upholstery cover. The size of the back shall be 52.0cm. (W) X 59.0cm. (H) X 6.0cm. (T) The adj. glide shall be injection moulded in black Nylon and fitted to the front end of side frame assembly along with ABS moulded adj. Glide base to take care or unleveled floor surface. Overall Dimensions of Chair shall be Seat Height - 43.5 cm, Height - 78.5cm, Width and Depth of Chair as measured from pedestal - Width-164.0cm and Depth-70.0 cm. 78 Providing and Placing in position Conference Table. Overal size of the Table shall be 6250 L mm x 2350 D mm x 740 H mm. The table top shall be made of 25 mm thick pre-laminated twin board, edge banded with matching 2 mm thick PWD edge banding. Plastic ABS access flap shall be provided for easy access to wires and cables. The Understructure shall be made of mixture of 18mm thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Aluminium alloy 63400 - WP profile shall be used for connecting panels together. Modesty Panel shall be made of 18mm Thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Powder coated accent metal strip shall be provided below work surface to enhance aesthetics. It shall be made of 0.8mm CRCA as per IS 513, and shall be epoxy polyester powder coated (DFT 40-60 microns). Wire Management shall be an array of panels made of 0.8mm CRCA MS IS:513, and shall be epoxy polyester powder coated (DFT 40-60 microns) shall be used for flow of wires and cables. Provision to mount 6 module switch plate shall be provided below worktop. Cutout on top with two piece injection moulded plastic part polymer component shall be fitted to pullout audio,video cables onto worktop and connect devices charger to power socket below worktop. 79 Providing and Placing in position Compactors for Record Room. Size: Overall Dimensions of 1200 mm (W) x 400 mm (D) x 2000 mm (H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel. Eachconfiguration have following type of blocks – Single Static (SS), Single Last (SL),Twin Mobile(TM). Finish: Finish shall be Epoxy polyester powder coated thickness of 40 microns. Construction: Shelf construction shall be made from CRCA steel 0.8 mm. Uniformly distributed load capacity of 100 Kg. Undercarriage: Undercarriage shall have construction in welded frame made of HR sheet 3 mm thick. Movement : The Movements shall be Drive Type configuration. Locking: Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is placed at suitable height .The ‘sprocket-chain’ arrangement is covered by a 1 mm thk. CRCA sheet Drive Unit Cover with dimensions 1202mm x 398mm x 87mm and is fixed onto the side of the body. Fixed unit (SD) does not have the Handle. Each units shall have Locking Knob for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts and bolts are galvanized / blackodized / Zn Plated.Also total no. of loading levels per understructure shall be 15 for SD3. Label holder: It is an aluminium extrusion of length 396mm for LD/SD and 796mm for TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394mm for LD/SD and 794mm for TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. Rail Pair: It consists of ‘C’ section 2 mm thk HR sheet and Square 25.4mm X 2mm thk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug and screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800mm, 1600mm and 2400mm. 80 Providing and Placing in position Main Chair. The cushioned seat assembly shall be consisting of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyster fabric. The cushioned back assembly shall be consisting of back inner moulded in Poly-propylene in-situ moulded with polyurethane and upholstered with high stretch knitted polyster fabric. The back size shall be 45.5 cm x 53 cm H and the seat size shall be 48.5 cm W x 49.0 cm D. The hig hresiliance polyurethane foam used in the seat and back cushion shall be moulded in density 45 plus /- 2 kg/m³ and hardness load shall be 16 plus /- 2 kgf for 25% compression. The seat and back shall be firmly connected to the frame and shall be cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need of complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with back movement during posture changes. The `S` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass -filled poly-amideform the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 positions tilt limit feature which is inbuilt in seat base and the tension shall be user weight dependent. The armrset assembly shall be made of housing sliding over the armrest struture, both moulded in glass-filled polyamide. The height djustment feature shall be button operated having adjustment stroke of 6.6±0.5 cm. The armrest top shall be made of integral skin PU moulded over plastic inner moulded in glass filled polyamide. The seat height can be adjusted with the pneumatic gas-lift having an adjustment stroke of 9.2 plus /- 0.3 cm. The pedestal shall be injection moulded in glass-filled poly-amide and fitted 5 nos. of twin wheel castors The pedestal shall be 66plus /- 0.5 cm pitch center dia. and 76plus /- 1 cm with castors. 5 nos. of twin wheel castors shall be injection moulded in poly-amide having 5.0plus /- 0.1 cm wheel diameter and assembled with pedestal. 81 `Providing and Placing in position Office Table. Overall size of the table shall be 1500 W mm x 750 D mm x 740 H mm. Worktop shall be made of 25mm Thick Pre-laminated board, Edge banded with matching 2 mm thick PVC lipping. Access Flap provided on work surface for wire management. Modesty shall be made of 18mm Thick Pre-laminated twin board, Edge banded with matching 2 mm thick PVC lipping. Legs shall be fabricated from MS ERW Tube of 50 mm x 25 mm x 1.2mm thick and 40 mm x 40 mm x 1.2 mm thick (as per IS: 7138). At the top surface of leg, support brackets of 3 mm thick HR (as per IS: 2062) shall be welded for fixing worktop. These shall be welded together by argo shield welding. This welded structure is coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert is fixed, on to which a straight M8 leveler fitted which allows for adjustment of the height upto 50mm. Cross Members shall be made from 50mm X 25mm X 1.2mm thick ERW tube (as per IS:7138). These shall be coated with 50 micron epoxy polyester coating. Cross Members shall be assembled by friction fit PDC joinery and grub screws. There are always two cross members for one table. Soft closing access flap shall be used in Table. Provision for standard size of 8 module electrical shall be offered. Access flap shall be made from Aluminum extrusion, PDC parts made from Aluminum. Alloy and plastic parts shall be made from Nylon 6 and wire brush with nylon bristles. Power box shall be made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 Modulecutout provision). This shall be fixed with worktop along the depth at Access Flap position. 82 Providig and Placing in poition Waiting Chair for Counsellor Room. The seat shell shall be a welded assembly ofseat,back and side frame. The seat and back shall be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They shall be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel. The welded assembly shall be powder coated ( DFT 40-60 microns). The seat shall has a front water fall edge to provide popliteal clearance for comfortable seating. It also shall has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flatsurfaces of seat and back shall aids in easy maintenance. The dimensions of seat shall be 47.8 cm (W) x 44.6 cm (D) and of back shall be 41.6 cm (W) x 23. cm (H). Understructure assembly shall consists of connecting beam and leg assembly made of M.S.E.R.W. oblong tube of size 7.5±0.03cm x5.0±0.03cm x 0.02±0.016cm thk.The welded structure assembly shall be powder coated (DFT 40-60 microns ).The leg assembly shall be fitted with shoes and levellers in Nylon. The leg structure shall be designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fiited to leg assembly shall help in aligning the structure for back to back arrangements. Levelers should take care of uneven flooring .Connecting beam shall be fitted with snap locking end cap.It also aids in side-by-side understructure alignment. Armrest assembly shall consists of armrest frame and armrest pad. The armrest frame shall be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it shall be powder coated (DFT 40-60 microns). Armrest pad shall be injection molded in Nylonand shall be fitted onto the armrest frame. Overall Dimensions shall beSeat Height - 44.1 cm, Height - 78.5 cm, Width and Depth of Chair as measured from pedestal - Width-169.5cm and Depth-63.8 cm. 83 Providing and Placing in position Café Table. Overall size of the Table shall be 1135 W mm x 1175 D mm x 750 H mm. Top shall be 25 mm thick( plus /-1mm) base material shall be 25 mm MDF board . On top PU painting of minimum 2H hardness with 75% glass as per color chart .Combination color graphics on the centre . Brown Laminate on bottom specially profiled edges for comfort . The Understructure shall be having bend pipe structure of MS powder coated . Pipe dia 38 mm , 2 mm thick and it shall be fitted with top by SS machine screws . Legs shall be of MS powder coated and 38 mm dia. pipe legs are fixed with inderstructure and table top . Glide shall be of Plastic fixed at the understructure to prevent the damage of table top during stacking . 84 Providing and Placing in position Café Chair. The single piece seat back shell shall be made up of injection moulded high impact strength glass filled polypropylene polymer compound. SHELL SIZE shall be 44.0 cm. (W) x 50.2 cm. (D) x 40.5 cm. (H). The powder coated (DFT 50±10 microns) welded tubular frame shall be made from Ø 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm M.S. E.R.W tube. The 0.16 ± 0.008 cm thk CRCA sheet shall be welded to tubes for fixing shell to the frame. The shoe shall be made of high impact strength polypropylene polymer compound and are fitted at the end of the tubular frame. 85 Providing and Placing in position Main Table for SHO Office. Overall size of the Table shall be 1800 W x 900 D x 750 H and ERU 1200 W x 600 D x 750 H. The table is made of 25 mm thick MDF – one side pre-laminate board confirming to IS-14587:1998 with 0.4 mm PVC membrane pressed on to top. Soft closing access flap within-build power box are provided on work surface for wire management. The ERU top is made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The modesty panel is made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. The understructure is made of 25 mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2 mm thick PVC lipping. The pedestal is made of 25 mm thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, edge banded with matching 2 mm thick PVC lipping. There shall be 2 Nos. of Drawer Units i.e., 1 Nos. under Main Table and 1 Nos. under ERU, where Drawer fronts shall be made of 25 mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 mm PVC membrane pressed on to top pedestal construction is BOX-BOX-FILE type which uses powder coated 400 MM long metal Panel Drawer Slides. Drawer extension is 325 MM. Drawers have a soft closing and anti slam mechanism. Handles are provided for ease of opening. Pedestals are provided with lock for security. 86 Providing and Placing in position Chair with Desklet for Teaching Room. The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The powder-coated (DFT 40-60 microns ) frame structure shall be made of 3.5±0.03cm x 1.5±0.03cm x 0.16±0.0128cm thk M.S. E.R.W.tube and welded connecting tube made of dia 2.22±0.03cm x 0.16±0.0128cm thk M.S. E.R.W. SQUARE tube to form the Mainframe assembly. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. The paper tray is made of dia 0.4plus /- 0.005cm M.S. rod which is spot welded to form a mesh typestructure. It is powder coated(DFT 50 plus /-10 microns). The size of the tray is 40.1 (W) x 36.1 (D) x 22.0 (H) cm. The `L` shape desklet is madeup of 1.8 plus /-0.05cm thk pre laminated particle board with 0.2 plus /-0.05cm thk injectio moulded polypropylene all around. Desklet has front and back adjustment of 4.4cmplus /-0.5 cm. The outer dimensions of desklet are 31.5 plus /-0.1cm (W) x 47.0 plus /-0.1 cm (D). An upholstery cover can be retro fitted on to seat and back. 87 Providing and fixing Laboratory Tables Understructure of required colour scheme consists of D-Frames Assembly, Horizontal members with Granite Top and Cover Panels. These understructures shall be of 750mm or 900mm height as per site requirement or as per the direction of Engineer-in-Charge. The Top surface area of under structure shall be measured for payment. The understructure shall comprises of following components :-. The Product must comply with SEFA -10 Standards and OEM must be the Member of SEFA for last 9 years. D-Frame Assembly`All D-Frames assemblies shall be manufactured from standard hollow metal sections: confirming to latest I.S. Code 7138 (Indian Standard specification for steel tubes for furniture) and all sheet metal components shall be of CRCA confirming to latest IS Code 513. The dimensions of D Frame shall depend upon the depth of the understructure. The overall depth (F) of DFrame shall be 705mm for 750mm Depth Structure and 555mm for 600mm depth (as per Drawing) and Depth of Extended Frame (G) shall be 255 mm for 750mm Depth and 110mm for 600mm depth (as per drawing). All frame-work shall be pre-treated with superior powder coated finish with 40-60 micron thickness. The structure of D-frame with horizontal units shall withstand 10 degree tilt (backwards) without toppling. The D-Frames shall have a provision to fix suspended storage cabinets. Side frame shall be of welded MS ERW tube of dimension 30 x 30 x 1.6mm thickness. Bracket for pipe : MS CRCA 2mm thick. Wall bracket : MS CRCA 2mm thick. Levelling screws: 2 nos. of M-10 levellers (MSplusNylon) Adjustments possible with range 20mm. `HORIZONTAL MEMBERSHorizontal members shall join two D-Frames to form the structure. Horizontal members shall be made from rectangular pipes of 1.6mm thickness. Cross-sectional dimensions of the pipe shall be 30 x 30mm with a minimum of 1.6 mm thickness. They shall be made of CRCA MS sheet powder coated of 40-60 micron thickness. Horizontal members connect two D-Frames together by using C-clamps/U-clamps together with the D-Frames and Horizontal Members . The skeletal structure of the work-bench is formed on which the worktop shall be placed and the hanging-type storage cabinets shall be suspended. Horizontal Members determine the width of the lab workbench as they form the member (distance) between two adjacent DFrames. They shall be available in various widths of 450mm, 600mm, 900mm, 1050mm, 1200mm, 1350mm, 1500mm, 1650mm and 1800mm (Toleranceplus /- 10mm). These horizontal units together constitute a table set. COVER PANELSAll side cover panels and back panels, filler panels shall be made from CRCA MS panels of minimum 0.8mm thickness with epoxy powder coating with thickness of 40-60 microns, bracket of min.1.2mm thickness WORKTOPThe complete structure shall be provided with a Worktop of 20mm ( plus /- 2mm) thick Jet Black Granite. The exposed edges of the worktop shall be chamfered and polished . The bottom of cantilever portion ofthe worktop shall be polished andV-groove shall be provided throughout the length of the exposed edges to protect the cabinets from coming in contact with the spillages. The overhang on the storage cabinet is 25 mm at the front side and 30mm at the sides. The backing materialshall be neoprene mat of 6 mm thickness. All the above items shall be as per photo, sketch specifications and direction of engineer-in-charge. 88 `Providing and fixing Work bench Storage cabinets of required colour scheme as per following:- The storage cabinet shall be Welded body with load bearing members such as top, bottom and stiffeners made of 0.8mm thick CRCA Sheet. A drawer separator shall be provided made of 1.2mm thick CRCA sheet. The storage unit shall be provided with a shelf made of 0.8mm thick CRCA sheet which is adjustable to 6 slots of 4060mm. Each shelfshall have load carrying capacity of 40 kgs. Shutter providedis overclosing with 270 degree opening. It has a sandwich construction with profile as a sound dampener.The drawer shall be provided as per the manufacturers specifications and direction of Engineer -in-Charge. The complete storage unit shall bepowder coated with thickness of 40-60 microns and is suspended from tubular understructure, with an overlay shutter. The cabinet has a corrosion resistance magnetic strip as shutter catch, shutter and drawer are equipped with 180 degree cam lock. Semi recessed handle and five knuckle overlay hinge(SS-304) with 270 degree opening. Drawer and Shutter shall be provided with a lock 180 Degree cam with 4mm thick lever. Cabinet fixing brackets shall be of 2mm thickness. Note:- The cost of storage cabinet does not includes the cost of basic understructure, the cost of understructure shall be paid in Item No 1. (All the above items shall be as per photo, sketch specifications and direction of engineer-incharge.) `Storage unit of Size 600mm(W) x 450mm(D) x 675mm(H) with 1 Drawer and 2 Shutters 89 `Providing and fixing Work bench Storage cabinets of required colour scheme as per following:- The storage cabinet shall be Welded body with load bearing members such as top, bottom and stiffeners made of 0.8mm thick CRCA Sheet. A drawer separator shall be provided made of 1.2mm thick CRCA sheet. The storage unit shall be provided with a shelf made of 0.8mm thick CRCA sheet which is adjustable to 6 slots of 4060mm. Each shelfshall have load carrying capacity of 40 kgs. Shutter providedis overclosing with 270 degree opening. It has a sandwich construction with profile as a sound dampener.The drawer shall be provided as per the manufacturers specifications and direction of Engineer -in-Charge. The complete storage unit shall bepowder coated with thickness of 40-60 microns and is suspended from tubular understructure, with an overlay shutter. The cabinet has a corrosion resistance magnetic strip as shutter catch, shutter and drawer are equipped with 180 degree cam lock. Semi recessed handle and five knuckle overlay hinge(SS-304) with 270 degree opening. Drawer and Shutter shall be provided with a lock 180 Degree cam with 4mm thick lever. Cabinet fixing brackets shall be of 2mm thickness. Note:- The cost of storage cabinet does not includes the cost of basic understructure, the cost of understructure shall be paid in Item No 1. (All the above items shall be as per photo, sketch specifications and direction of engineer-incharge.) `Storage unit of Size 450mm(W) x 450mm(D) x 675mm(H) with 1 Drawer and 1 Shutter 90 `Providing and fixing Sink Units of size 600mm(W) which shall comprises of Sink Cabinet, Polypropylene Sink Unit and 1-Way Goose Neck 360 Degree revolving Faucet.as per following SINK CABINET`Sink cabinet. :- The Sink cabinet shall be Welded body with load bearing members such as top, bottom and stiffeners made of 0.8mm thick CRCA Sheet. The cabinet unit shall be provided with Pair of Shutters. Shutter has a sandwich construction with profile as a sound dampener. The complete unit shall be epoxy powder coated with thickness of 40-60 microns and is suspended from tubular understructure, with an overlay shutter. The cabinet has a corrosion resistance magnetic strip as shutter catch. Shutter shall be provided with semi recessed handle and five knuckle overlay hinge (SS-304) with 270 degree opening. Cabinet fixing brackets of 2mm thickness. The cost of sink cabinet does not includes the cost of basic understructure as the cost of understructure shall be paid in Item No 1. All the above items shall be as per photo, sketch specifications and direction of engineer-incharge. `POLYPROPYLENE SINK ASSEMBLY`Providing and fixing Polypropylene Sink with PP Waste, Anti-Siphon Bottle Trap and Flexible Drainage Pipe. Sink bowl shall be Polypropylene Molded made up of 5mm thick high density and elastic poly propylene with good resistance to organic solvents. Standard bowl size shall 500mm(L) x 400mm(W) x 300mm(D). `1 WAY WATER FAUCET`Providing and fixing 1-Way 360 Degree Revolving Water Faucet. Faucet fittings shall be laboratory grade. Water faucet and valve bodies shall be cast red brass alloy or bronze forgings, all fittings shall be powder plated. Brass as perIS:319, Pipe as per : IS:407,O utlet nipple in PP construction. PP knob to be used. All gasket and O-ring of Nitrile Rubber make. Inlet connection 1/2`` BSP. Gooseneck spout with 360 degree rotation with 100000 life cycles. Pneumatic test at 250 psi, hydraulic test at 125 psi, bursting test at 500 psi. Coating to be glossy epoxy fusion bond. The Faucet shall be fixed to the existing water outlet by providing PVC connection with brass unions of required length. All the above items shall be as per photo, sketch specifications and direction of engineer-in-charge. 91 Providing and fixing 2 Tier Reagent Racks of size 1100mm(L) x 300mm(W) x 680mm(H):- Reagent Racks shall be complete modular design consisting of 2 stage horizontal storage shelves made of1.6 mm thick frame. Shelf : Fixed-Type reagent shelves have 1.6mm thickness consisting of 2 stage horizontal storage shelves made of1.6 mm thickframe of CRCA MS sheet withepoxy powder coating and shall have 4 nos. plates (containing 03 module each) for electrical switches and sockets including necessary wiring etc. It shall have provision for placing Granite pieces. Cutout for 3 module plate to be provided. All the members are knock down and can be restructured. Themetal part cutout shall be of 1.00mm thickness. The finish shall be coating of 40-60micron thickness. Load carrying capacity of 70kg for Island table. All the above items shall be as per photo, sketch specifications and direction of engineer-incharge. 92 ELECTRICAL TRUNKINGProviding and fixing Bench Mounted Electrical Trunking. Electrical Trunking body cover shall be of minimum 1.2mm thickness. Used for housing electrical switches and sockets, data and voice points, its top panel, bottom panel of the trunking should be made from minimum of 0.8mm thick body.Bottom plate below trunking to avoid leakage made of 6mm thickness PP sheet It should be available in both, single sided and double sided configurations. It should be made from CRCA MS with pure epoxy powder coating with minimum 50 microns tickness . The front surface that houses the electrical points should have a slope. Size of each unit shall be 220 mm W x 86.5 mm D x 92.5 mm H. All the above items shall be as per photo, sketch specifications and direction of engineer-incharge. 93 Providing and Placing in position Lab Stools.Overall Sizes Diagonal LegDia 538 mmH470 min-655maxTop plate should made of SS 202 made sheet with spin section of thickness 1mm and should be non corrosive. It should have a diameter of 305mm,seat base should made of MS ring and rectangular tube.EN8 Screw having dia of 22 mm should be used for height adjustment of the seat base.The round hub should be made of MS ERW tube having dia of 38mm and thickness 2 mm.The Hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.The understructure should consist of 4 legs made up ofMS ERW tube of diameter 25.4 mm and 1.6mm thick. The press formed pipe leg should give a round and clean look. All the legs should be provided with 4 nos of Nylon-6 bush.All metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coatingto fulfill the requirements for bacterial protection against at least 2 commonly found bacteria in Hospital environment [Gram positive and Gram Negative].Safe working load must be 135kg 94 Providing and Placing in position Reading Tables. Providing Desk based system that has been designed to give a richer experience. The system should cater to different work activities with well-equipped layouts and zones created by the system’s different elements.Worktop: Worktop shall be made of 25MM thick Pre-Laminated Board conforming to IS: 12823. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. The worktop shall be complete with provisions for screen mounting as well as for wire management on the workstation. Provisions for fixing of the switches shall be on the wire tray/channel. Access flaps with soft closing technology shall be provided on the table tops to access the switch points on the tray. Understructure: The slanted legs shall be connected to the understructure with the help of PDC Connectors to provide a stable and sturdy base for the worktops. Modesty panel shall be of Acrylic (8 mm thick Acrylic both side frosted) or of Metal 1.2 mm thick CRCA. Wire Management: It shall be a part of the understructure and can be in the form of enclosed metal tray or 2 level enclosed channel to provide concealed wire management throughout the cluster formation. Wire riser leg or independent wire risers shall be provided as per the layout structure.Screen: Screen shall be provided as per the requirement of the design and layout. The screen shall be made of 3mm thick MDF Boardplusbatten made of 12 mm thick MDF Boardplus3 mm thick MDF Board. Honey comb blocks shall be used to fill in the void space. Groove of 3 mm shall be provided on the periphery to accomodate the fabric pasted on either side to be tucked in and allow a PVC flexible T-Mould to give clean edge. Recta - 1800 W mm x 900 D mm x 750 H mm 95 Providing and Placing in position Reading Tables. Providing Desk based system that has been designed to give a richer experience. The system should cater to different work activities with well-equipped layouts and zones created by the system’s different elements.Worktop: Worktop shall be made of 25MM thick Pre-Laminated Board conforming to IS: 12823. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. The worktop shall be complete with provisions for screen mounting as well as for wire management on the workstation. Provisions for fixing of the switches shall be on the wire tray/channel. Access flaps with soft closing technology shall be provided on the table tops to access the switch points on the tray. Understructure: The slanted legs shall be connected to the understructure with the help of PDC Connectors to provide a stable and sturdy base for the worktops. Modesty panel shall be of Acrylic (8 mm thick Acrylic both side frosted) or of Metal 1.2 mm thick CRCA. Wire Management: It shall be a part of the understructure and can be in the form of enclosed metal tray or 2 level enclosed channel to provide concealed wire management throughout the cluster formation. Wire riser leg or independent wire risers shall be provided as per the layout structure.Screen: Screen shall be provided as per the requirement of the design and layout. The screen shall be made of 3mm thick MDF Boardplusbatten made of 12 mm thick MDF Boardplus3 mm thick MDF Board. Honey comb blocks shall be used to fill in the void space. Groove of 3 mm shall be provided on the periphery to accomodate the fabric pasted on either side to be tucked in and allow a PVC flexible T-Mould to give clean edge. Recta - 900 W mm x 600 D mm x 750 H mm 96 Providing and Placing in position Chair. The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The Tubular welded frame is made of made of 3.5±0.03cm x 1.5±0.03cm x 0.12±0.0128cm thk M.S. E.R.W.tube and welded connecting tube made of dia 2.22±0.03cm x 0.12±0.0128cm thk stainless steel 202 grade tube. The tubes are buff polished to give shiny finish. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. An upholstery cover can be retro fitted on to seat and back. The seat cover is made from High abrasion resistance fabric with foam lamination and 2.5cm PU foam insert. The back cover is made from high abrasion resistance fabric with foam lamination and 0.1 cm PU foam insert. 97 Providing and Placing in position Double Sided Book Rack. Overall size of the rack shall be 1200 W mm x 600 D mm x 2078 H mm. Side panels, Frame and Cross L bracket shall be made using 0.8 mm CRCA. The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles. The tie rods shall be fixed in a shape of ‘X’. The tie rods shall be made of 4mm diameter rods of MS while fixing brackets shall be made of 2mm thick CRCA. Wooden panel of 25mm thk PLT, E1-P2 grade board shall be provided on sides, edges shall be provided with machine pressed 2 mm thick PVC lipping glued with hot meltEVA glue. Under structure shall be made of 0.8m CRCA. Shelves used shall be 10 bend panel made of 0.8mm CRCA. Shelf panels shall be placed on shelf support and then fixed using nutand bolts from below. It consists of 6 loading levels formed by 5 no ofadjusted shelf. Uniformly Distributed Load Capacity per each shelf shall be 80 Kg maximum. All MS sheetmetal and metal frame components shall be powder coated with epoxy polyester powder to the min thickness of min 45 microns. 98 Providing and Placing in position Periodical Display Rack. Overall size of the rack shall be 900 mm (W) x 450 mm (D) x 1830 mm(H). Rigid Knockdown construction ,Panels shall be made from CRCA 0.6 mm thick and front frame shall be made from CRCA 0.8 mm thick . CRCA D grade as per IS 513 . There shall be 5 level racks , Display tray shall be suitable for fullscape size magazines,periodicals, aesthetically appealing metal tray at an angle for easy viewing . Receding facility to access the storage behind . Sliding on plastic rollers . Behind storage shelving each of 5 level has a behind storage shelf . Uniformly Distributed Load capacity per each shelf is 40 kg . Leveler shall be screw type with hex plastic base and finish shall be epoxy polyester powder coated to the thickness of 50 microns . 99 Providing and Placing in position Bookcase. Overall size of the bookcase shall be 914 mm (W) x 320 mm (D) x 1742 mm (H). The unique design provides the right rigidity to the Top hinged doors , which shall facilitate easy use. The Book Case shall be made from prime quality CRCA steel with anti rusting treatment. It shall have a Rigid Knock Down Construction. The Top Pannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA and other components from 0.8mm CRCA.Each door shall have a 6 Lever Cam Lock with Common Key. 3mm thick glass should be used in each door for clear inside vision whih shall be secured in a metal frame through a rubber gasket. Scissor Mechanism should be provided in each door for receding inside the top of every compartment and it shall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which is easy to grip. Each compartment shall have a storage shelf with a UDL capacity of max 80 Kg. The 4 Door Book Case shall have metal inside top panel.The finishing shall include Epoxy powder coated to the thickness of 50 microns ( plus /- 10). 100 Providing and Placing in position Plain Almirah. Overall size of the Almirah shall be 916 mm (W) x 486 mm (D) x 1980 mm (H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. It should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It shall have 4 no.s full shelves. A4 size box file(85 W x 285 D x 345 H mm) can be stored vertically on three shelves and the clear space above fourth shelf is 240mm. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns ( plus /- 10). There shall be 5 loading levels in the almirah. 101 Providing and Placing in position Visitors Chair. The cushioned seat assembly shall be made of injection moulded plastic outer and inner. Plastic inner is upholstered with stitched cover and moulded high resiliance polyurethane foam of density 45plus /- 2 kg/m³ and hardness load of 16plus /- 2 kgf for 25% compression. The stitched cover shall be made from spacer fabric and leatherette. Seat size shall be 47 cm W x 48 cm D. The cushioned back shall be made of PU foam with insitu molded MS ERW round tube of size 1.9plus /- 0.03 cm x 0.16plus /- 0.0128 cm. It shallm be upholstered with spacer fabric and leatherette. The back size shall be 45 cm W x 60.5 cm D. The tubular frame shall be powder coated and shall be cantilever type. It shall be made of Ø2.54 plus /-0.03 cm x 0.2 plus /-0.016 cm thick MS ERW Tube. Back shall be conected to the frame throug powder coated high pressure die casted connector piece.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
33.
Defence #10087646 Price Bid
Repair Of Motors, Pump, Panels, Starters, Installation Misc Items Etc And Preventive Maintenance Of Water Supply Pump Installation At Ahmedabad Cantt ( Tender Id : 2021_Mes_413377_1 ) - 1 Carrying Out Scheduled Maintanence And Servicing Of All Electro - Mechanical Machinery / Panel Of Existing Centrifugal, Submersible, Monobloc Pump, Motor And Accessories Any Type Any Make & Model In Every 07 Days Or When Ordered Including Cleaning Its Part, Removing Corrosion, Refixing It, Rectifying Leakage Due To Loose Nut / Stud / Gland Packing / Gland Rope / Star Packing / Clamps / Washers Etc Of Suitable Size As Required. Details Of Maintenace Should Be Recorded In Register . 2 Dismantling, Opening, Rewinding And Refixing Induction Motors Of Centrifugal Pump Set With Super Enameled Copper Wire Of Existing Gauge And Existing Class Insulation Including Superior Quality Varnishing, Heating / Drying Coils, Making Connections From Coil To Terminal Box, Greasing Ball Bearings, Spray Painting With Two Coats Of Synthetic Enamel Paint, Necessary Mechanical Works For Shaft / Bearing Housing, Transportation From Installation To Workshop & Back, Connecting, Testing And Commissioning At Site For Satisfactorily Operation As Required For The Following:- 3 40 Hp Motor 4 30 Hp Motor 5 25 Hp Motor 6 20 Hp Motor 7 10 Hp Motor 8 7.5 Hp Motor 9 5 Hp / 3Hp Motor 10 Dismantling And Taking Down Centrifugal Pump Set 20 To 40 Hp Capacity, 3 Phase, 440 Volts From Foundation, Disconnecting All Electrical Connection From Induction Motor, Transportation From Installation To Workshop, Renewal Of U / S Spare Parts, Re-Assembling Pumping Set Including Testing And Commisioning Complete. ( Note :- Spare Parts Shall Be Measured Separately Against Item No 4 Of Boq As Supply Only ) . 11 Supply Only Following Spare Parts Suitable For Existing 20 To 40 Hp Centrifugal Pump Set As Required:- 12 Ball Bearing Suitable For Centrifugal Pump Set 20 To 25 Hp. 13 Ball Bearing Suitable For Centrifugal Pump Set 30 To 40 Hp. 14 Ci Impeller Suitable For Centrifugal Pump Set 20 To 40 Hp. 15 Shaft 16 Low Joy Coupling Including Rubber Star Packing & Necessary Key For Fixing On Shafts As Required. 17 S&F Rubber Star Packing For Joy Coupling Fitting . 18 Renewal Of Following Spare Parts Suitable For Existing Starter Panels As Required:- 19 Ml-6 Contactor 110 Amp. 20 Ml-4 Contactor 70 Amp. 21 Ml-2 Contactor 32 Amp. 22 Ml- 1.5 Contactor 25 Amp. 23 Single Phase Preventor. 24 Timer For Ats Starter With Coil. 25 Ml-1 Relay As Per Existing. 26 Ml-1.5 Relay As Per Existing. 27 Ml-2 Relay As Per Existing. 28 Ml-3 Relay As Per Existing. 29 Ats Transformer Copper Wound As Per Existing With Taping At 50%, 60% And 70%, 3 Phase, 415 Volts Upto 75 Hp Submersible Pump Motor As Per Existing. 30 Excavation In Trenches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Deep In Soft / Loose Soil Including Forming Sides And Bottom Surface To Required Levels / Slopes / Gradients And Getting Out Complete. 31 Returning, Filling In Trenches Including Spreading Leveling, Watering Well, Ramming In Layers N.Exc 25 Cm Thick In Soft / Loose Soil Complete. 32 Removing Excavated Material To A Distance N Exc 50 M And Depositing At A Level N Exc 1.5 M Above Starting Point Complete. 33 S&F Cpvc Pipes Sdr 11 And Plain Cpvc Sdr 11 Fittings With Required All New Fitting Isi Marked Fixed On Trenches With Fixing Arrangement Of Following Sizes:- 34 25 Mm Bore 35 32 Mm Bore 36 40 Mm Bore 37 Taking Up Or Down Gi Steel Tubing And Connections Of Any Description Including Cleaning For Refixing Or Removal To Store Complete. 38 25 Mm Bore 39 32 Mm Bore 40 40 Mm Bore 41 Supply Only Gi Pipe Medium Grade With Socket. 42 15 Mm Bore 43 20 Mm Bore 44 Supply Only Of Gun Metal Globe Or Gate Valve Isi Marked With Iron Wheel Head Screwed Both Ends For Iron Pipes Of Following Sizes:- 45 15 Mm Bore 46 20 Mm Bore 47 25 Mm Bore 48 40 Mm Bore 49 S&F 15Mm Bore Bib Tap Standard Of Ptmt Any Colour High Pressure Screwed For Iron Pipe And Fixed In Repair Complete All As Specified And Directed. 50 Supplying And Laying Cast Iron Pipe With Spigot & Socket Ends Centrifugally Cast Class La Isi Marked Suitable For Lead Joints Laid In Trenches Of Following Bores:- 51 80 Mm Bore 52 100 Mm Bore 53 150 Mm Bore 54 Taking Up Cast Iron Pipe Line ( Including All Fittings ) With Spigot And Socket Ends And Lead Joints Including Burning Out Joints And Recovering Lead For The Following Bore Of Pipes:- 55 80 Mm Bore 56 100 Mm Bore 57 150 Mm Bore 58 Cast Iron Bends ( Any Type, Radius And Angle ) Tapers Any Type ( Straight, Bend, Increasing, Decreasing Or Double Socket Etc ) Tees Pieces Single Branches, ‘Y’ Junction, Double Branch Cross ( All Sockets Or Socket & Spigot ) Collar, Caps And Plugs Etc From 200 Mm To 300 Mm Bore Size Complete All As Specified And Directed. 59 Cast Iron Bends ( Any Type, Radius And Angle ) Tapers Any Type ( Straight, Bend, Increasing, Decreasing Or Double Socket Etc ) Tees Pieces Single Branches, ‘Y’ Junction, Double Branch Cross ( All Sockets Or Socket & Spigot ) Collar, Caps And Plugs Etc Upto 150 Mm Bore Size Complete All As Specified And Directed. 60 Construction Of Brick Masonry Valve Pit Chamber With 3 Mm Thick Ms Sheet Cover And 40 X 40 X 6 Mm Angle Iron Frame Embedded In Pcc Coping 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregates With Locking Arrangements Of Size 1200 Mm X 1200 Mm X1200 Mm Depth ( Internal Size ) , Brick Work In Cement Mortar 1:4 Using Sub Class ‘B’ ( Old Size ) Bricks, Internal Walls Plastered With 15 Mm Thick Cement Mortar 1:4 And Finishing The Surface Even And Smooth Using Extra Cement, 40 Mm Thick Pcc 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregate In Coping, Pcc 1:4:8 Type D-2 Using 40 Mm Graded Stone Aggregates In Foundation 75 Mm Thick With And Including Necessary Excavation & Earth Work In Soft / Loose Soil Complete All As Specified And Directed. 61 Supply Only Teflon Tape In 10Mtrs Roll 62 M&L For Flow Chart Diagram Of Pump House Indicating No Of Pump Installed , Sumps, Ohr , Suction , Rising Main , Delivery Lines Made The Help Of Computer Graphics And Pasted On 3Mm Thick Acrylic Sheet Duly Framed In Pvc And Fixing At Pump House Appx Size 1Mtr X 1 Mtr -10 Nos 63 M&L For Shock Treatment Chart Standred Size With Written In Hindi / English And Local Language. 64 M&L For Rubber Mat Of 1 Meter X 2 Meter X 19 Mm Confirm To Isi Complete All As Specified And Directed. 65 Renewal Of Existing Ms Sump Mouth Cover With Cast Iron Cover 4 Mm Thick And Nominal Size 0.60 M X 0.60 M Framed In 25 Mm X 25 Mm X 4 Mm Thick Angle Iron Including Fixing With Suitable Hold Fast And Hinges To The Sump Mouth As Required. 66 Dismantling Existing Unserviceable Water Meter From Valve Chamber And Supply And Fixing New Bulk Water Meter Woltman Type With Following Features Nominal Size 300Mm ( 12 ) Make : Kranti And Asihi Or Equivalent 67 Removable Element Structure 68 Class B Dry Dial, Magnetic Drive, Small Presure Loss. 69 Hermetically Sealed Registerensures The Dial Keep Free From Fog And Keep The Reading Clear In Long Term Service. 70 Selected High Quality Materials For Steady And Reliable Characteristic. 71 Technical Data Confirm To International Standard Iso 4064. 72 Cast Iron Body, Epoxy Powder Coated. 73 Work Inciudes Fixing Of New Gi Nuts Bolts Of Suitable Size And Any Other Work Required For The Fixing Of Meter At Site . 74 Test Certificate Of Meter Shall Be Produce . 75 All As Per Item No 26 Above But Nominal Size200mm ( 8 ) . Make : Kranti And Asihi Or Equivalent 76 All As Per Item No 26 Above But Nominal Size 80Mm ( 8 ) . Make : Kranti And Asihi Or Equivalent 77 S & F Pvc Flexible Conduit With Flexible Coupling 40Mm Dia Including Dracing Of Existing Wire Connecting With Existing System All As Directed At Site 78 M&L For Mccb Four Pole 250 Amps, 30 Ka, Thermally Adjustable Between 70% To 100% As Per Havells Cat Ref No. Ihlfnfo250 Or Equivalent In Schneider Or Hager As Approved. 79 Renewal Of Pvc Braided Pipe ( House Pipe ) Heavy Duty 150 Mm Bore For Suction In Sewage Line Complete. 80 Supply Only Scs- 10K 1% Chlorine Dioxide In Powder Form 2 Components ( Component A And Component B ) Based Disinfectant Chemical ( Solid ) Content For Water Treatment Packed In 1Kg Drum. 81 The Quoted Product Must Be Approved By Fssai 82 The Brand Of Chlorine Dioxide Must Have Valid Nsf / Ansi Certificate . 83 The Item Shall Have E-In-Cs Brand Ahq Approval 84 Dismantling, Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 85 Demolition Of Cement Concrete In Ground Floors And Pavings Not Exc. 15 Cm Thickness ( Below / Above Ground Level ) Complete All As Specified And Directed. 86 M&L Pcc 1:3:6 Type C2 Using 40Mm Grade Stone Aggregate As 75Mm Thick As In Sub Base Finished Fair Complete All As Specified And Directed. 87 M&L Machine Pressed Pre Cast Concrete Rubber Moulded Coloured, Prepolished Interlocking Paver Block Any Shape And Size Confirming To Is 15658-20006 Of 60Mm Thickness, M-30 Grade With Grey Cement And Pigment Complete All As Specified And Directed. 88 M&L Pcc 1:3:6 Type C1 Using 20 Mm Grade 1 Stone Aggregate 75Mm Thick As In Sub Base Finished Fair And Smooth Complete All As Specified And Directed. 89 M&L For Pcc 1:2:4 Type B-2 Using 40Mm Graded 100Mm Thick As In Path / Hard Standing Surface Finished Even & Smooth Complete All As Specified And Directed. 90 M&L Sand Filling 50Mm Thick Under Floor / Over Floor Or In Foundations Including Well Ramming . 91 S&F Precast Pcc Kerbs Stone Machine Pressed Factory Made Of Size 250 Mm To 450Mm Long , 100 Mm Thick & 350 Mm Depth In Pcc 1:2:4 Type B0 Using 12.5Mm Graded Crushed Stone Aggregate Maximum Depretion From A Straight Edge , In All Necessary Earth Work Complete As Required And Directed . 92 Renewal Of Cast Iron Sluice Valve Class Pn-1.6 Isi Marked, Both Ends Flanged, Stainless Steel Spindle, With Iron Wheel And Necessary Jointing Materials, Nuts & Bolts, Washers Etc For Making Two Flanged Joints Of Following Sizes As Required:- 93 80 Mm Bore 94 100 Mm Bore 95 S&F Brush Wooden Frame 60 Cm Long And 8 Cm In Width With Fibre Strands To Suction Sweeper At Swimming Pool.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
35.
Housing Urban and Rular Development #10052526 Price Bid
Implementation Of National E-Vidhan Application (Neva) End-To-End Digital Transformation Of Legislative Assembly. (Sh I- Providing Digital Transformation Facilities At Legislative Assembly) (Sh- Ii Provision Of High Speed Data Networking Poe / Network, Switches Ic Necessary Cabling And Accessories At Legislative Assembly).- 1 (SH:- I Audio Visual System ) 2 SITC of Digital combi Conference Control unit / Server units. Units must be Dante enable (must have minimum 2 Dante/ Network Ports) inbuilt from factorywith Integrated dynamics processor with programmable threshold, ratio, attack, and release of noise gate, AGC and limiter functions/ DSP with adaptive acoustic feedback, echo cancellation, parametric equalizer ( Dante, dynamic processor can be built to the controller/ server or integrated power supply unit) Unit Should have minimum 1 x Power Connectors, minimum 3 x Conference Network Ports or more than 1 x LAN Port, 1 x Balanced XLR audio input or more , 1 x Balanced XLR audio output or more, must be a capable of automatic or manual take-over of the Controller/Server by a spare controller units in case one would become inactive ,in built or external Recording capabilities, Audio Routing, Network Monitoring, Built-in diagnostics application and camera control capability., The Controller should be work on shielded network(non-proprietary) the above ports features can be complied through controller or integrated power supply. Controller Unit should support Voting & Interpretation. 19 Rack Mountable. Controller and server units should be from same OEM. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR 144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 3 SITC of integrated Power supply cum controller for conference unit with On/Off rocker/ switch with built-in indicator. It should have 48 V, LED indicator or better, Power good TTL output/ LED indicator provided on a sub D9 connector or better RJ 45 ports or Six 3-pin detachable Phoenix connectors are provided at the rear of the Power supply 1U or more to branch off the 48 V. 1U, 19 rack module, Mains power input: 100-240 VAC 60/50 Hz Output voltage: 48 VDC, Protection Short circuit: Overload, Temperature, Over voltage, Technology: Switched Mode Power Supply Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 4 SITC of one/two or more upstream ports towards the Central Unit. 2 or more powered downstream ports towards the network/ conference field devices. Network Extender cum change over unit extended powering unit supports redundant loop cabling. It shall be possible to daisy chain and loop several network extenders on the conference controller network. It shall be possible to loop Chairman/Delegate units between several network extenders to create redundancy on a network extender level, The Network Extender cum change over unit is powered via the external power unit. Conference OS software application detects possible failure and starts the switch over process accordingly by the operator commands. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 5 SITC of Integrated Flush mount Delegate conference unit with Speaker Built-In and with removable microphone capability, supported for Voting and simultaneous Interpretation, microphone push button with integrated LED, Physical / Capacitive 5 clear voting buttons with LED indicators. Should have in build with RFID/ NFC card reader for identification and authentication, Channels selector button with a OLED/ LCD display and headphone volume control, Built-in high- quality loudspeaker, minimum 1W or as per OEM, built in speaker frequency response: 200-15,000 Hz or better, Speaker shall automatically muted/ active when the microphone is active, to prevent acoustic feedback available in custom colours dimension, finishes, construction: steel / metal or as pr OEM, only 3.5 mm stereo jack sockets for headphone connectivity. “Connectivity: › 2 x RJ 45 port (IN/OUT). Loop through, daisy-chain cabling (non-proprietary).USB-C or mini-USB or mini din, Push & Lock/ screw socket to connect the detachable microphone. Microphone Input: › Dynamic range: > 90 dB or better › THD: 0.1% or better.Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 6 SITC of Integrated Flush mount Chairman conference unit with Speaker Built-In and with removable microphone capability, supported for Voting and simultaneous Interpretation, microphone push button with integrated LED , Physical / Capacitive 5 clear voting buttons with LED indicators. Should have in build RFID/NFC card reader for identification and authentication, Channels selector button with a OLED/LCD display and headphone volume control, Built-in high-quality loudspeaker, minimum 1W or as per OEM, built in speaker frequency response: 200-15,000 Hz or better, Speaker shall automatically muted/ Active when the microphone is active, to prevent acoustic feedback available in custom colours dimension, finishes, construction: streel / metal or as pr OEM,only 3.5 mm stereo jack sockets for headphone connectivity. “Connectivity: 2 x RJ 45 port (IN/OUT ). › Loop through, daisy-chain cabling (non-proprietary).USB-C Push/ mincon/ mini din& Lock/ screw socket to connect the detachable microphone. Microphone Input: › Dynamic range : > 90 dB or better › THD: 0.1% or better. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 7 SITC of Gooseneck Microphone 360 MM or above or as per site requirement must have a single/ dual flex gooseneck microphone (flexible top and lower sections) is equipped with USB C-based / mini-USB/ mini din push and lock/screw connector Polar Pattern: Cardioid/ Uni directional or better Shielded microphone, immune to mobile phone interference. Transducer principle: Back electret (condenser). Frequency response: 125 to 15000 Hz or better. Sensitivity @ 1 kHz/ Nominal input level : -43 dBV/Pa/ 85 dB SPL or better. Maximum SPL @ 1 kHz : 110 dB SPL or better. Signal-to-noise ratio/ Equivalent noise : 15 dB or better. Dynamic range : 90 dB or better. Microphone LED ring configurable with selection of RED and Green colour USB-C/ minicon/ mini din -based microphone connector. Connection: Push & screw /Lock. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 8 SITC of conference software should offer all-in-one software package that simplifies room setup and meeting control. Easy step by step configuration wizard and Room layout configuration for the technician Roles for meeting control: › Operator › Chairperson › Signage Specify available controls for each role and Capability to protect roles with password Create a single meeting template including:› Title › Delegates and seating › Optional badge configuration › Optional external recording of the meeting audio Start a meeting from the template or a new meeting It should Manage speakers from room layout, Manage the speaker list, Manage request list with drag and drop re-ordering capability. It should Start a voting session, Voting question, 2 or 3 options for voting and Public or secret voting It should have Signage for Meeting view with Room layout, speaker list and request list, Voting view with results screen, Dynamically switch between meeting and voting view when voting starts / stops. Consult or save up to 20 meeting reports, The reports contain meeting participants, the recording (if available) and timestamped voting items with overall and individual vote resultsVoting results are visualized in the operator, and chairperson screen, but also the signage screen will toggle to visualize the voting results Whenever a need arises a voting can be started on the fly. The voting gets a description, and it can be defined if it is a public or secret vote. In a meeting template participants can be added by simply typing their name and adding them to their assigned seat. Additionally, an RF-ID card can be assigned, allowing participants to identify themselves by logging into any conference device in the room. 9 SITC of Light weight headphone unit Transducer principle: Dynamic as per OEM Load rating: 20 mW or better Impedance: 32 Ω or more, Sensitivity: 94 dB/mW(+ 3 dB at 1 kHz) or better, as per OEM Frequency range 35/50-15,000 Hz or better, Connector: 3.5 mm stereo jack. complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 10 Supply & Laying of Conference Cable 2 Mtr or as per OEM recommended Cat6 shielded cable with high quality STP end connectors complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 11 Supply & Laying of Conference Cable 20 Mtr or as per OEM recommended Cat6 shielded cable with high quality STP end connectors complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 12 SITC of 6 two-way ceiling/ Surface mount speaker with at-least 0.5 HF driver. The speaker must have frequency range (-10 dB) of 70 Hz – 20 kHz; Sensitivity > 88 dB (1W/1m), delivering Max. Calculated SPL (peak) > 100 dB with continuous power handling 30W @ 100V or less. The speaker should have transformer tapping up to 30W .The speaker cabinet should have at-least 170°conical dispersion pattern complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 13 SITC of 240w mixer amplifier with Inbuilt Bluetooth for audio streaming and supports audio playback from USB pen drive with4 microphone/line inputs, plus music source input and insert feature to use as a pre/power amplifier. It also has optional 2 tone chime generation for input 1 complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 14 Supply, Installation, Testing & Commissioning of open architecture DSP having 12 mic/line level inputs with AEC and phantom power, 8 line level outputs, 4x4 USB audio channel, 8 Digital I/O ports, Dante, minimum 4 x RJ-45 Dante ports, minimum 8 audio files can be stored in in-built storage for playback including pink noise, white noise etc, minimum 16 channel bi-directional digital audio expansion bus, zoom & Microsoft teams certified, sampling rate: 48KHz or better, Ethernet monitoring and control, Front panel main input and output signal presence and clipping LEDs; THD + Noise <0.02% or better; Crosstalk <- 90 dB or better; processor: 64-bit. Certified for Microsoft Teams and Zoom for Audio and Video collaboration complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 15 Supplying and laying of 16 AWG 2-core speaker Cable with 19-strand annealed bare copper conductors; Semi- rigid PVC insulation; Twisted, unshielded; Riser rated PVC jacket; NEC CL3R, CEC CMG, RoHS compliant complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge. 16 Supply, Installation, Testing & Commissioning of AV Quad Core control processor with minimum 1x RS232/RS422/RS485, 1x bidirectional RS232 or more, 2 or more IR/Serial, 4 or more Relay, 4 or more Digital I/O. control AV devices over Ethernet port supporting 10/100/1000Base-T and should support IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTPS, NTP, SFTP, SMTP, SNMP, SSH protocols. Should have SDRAM: Min 2GB or more and Flash Memory: Min 8 GB or more. Should have Built-in IR receiver for recording IR commands. Should be Operational in up to 45°C temperature. Should have Regulatory compliance: CE/UL or any equivalent complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 17 Supply, Installation, Testing and Commissioning of 10 Tabletop capacitive touchscreen with 1280x800 resolution and 24-bit color depth, Pixel density 149 PPI; Aspect ratio - 16:10; Brightness- 420 nits; Contrast - 800:1; Viewing angle ±85° horizontal, ±85° vertical; SDRAM- 2GB, Flash- 8 GB; Motion & Lighting sensor- On/off OR Auto/manual; Connectors — 1 x female RJ-45; Data rate: 10/100/1000Base-T, half/full duplex with autodetect; Protocol DHCP, DNS, HTTP, HTTPS, ICMP, IEEE 802.1x, SFTP, SSH, TCP/IP, UDP/IP; Touch panel and control processor should be from same OEM complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 18 Supply, Installation, Testing and Commissioning of 98 4K UHD(3840 X 2160) Slim DLED display, Aspect Ratio 16:9, Brightness 600 Cd/m2 or better, Pixel Pitch 0.5622mm(H) × 0.5622mm(V) or better, Haze 30% or better, Viewing Angle 178°or better, HDMI IN X 3, HDMI Output X 1 ,Audio Output 1 x 3.5mm, USB 2.0 X 1 ,USB 3.0 X 1 ,RS232 X 1, LAN X 2(IN/OUT), USB Type-C X 1, 4GB DDR4 memory, 32GB storage, 24 W in built speaker, 24/7 operation, Operation Temperature:0℃ - 45℃, Operation Humidity: 10% - 90%. complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 19 Supply, installation, testing and commissioning of iPad Pro 13″ (M4): Ultra Retina XDR Display, 1TB, Landscape 12MP Front Camera / 12MP Back Camera, LiDAR Scanner, Wi-Fi 6E, Face ID, All-Day Battery Life, Nano-Texture with app from conference OEM if control of IPAD and running of NIC application is required from the conference server complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site including adaptor for USB C to RJ 45. 20 Supply, Installation, Testing and Commissioning of 4K @ 60 fps PTZ Camera with minimum 30X Optical Zoom, min 100 Presets, simultaneous output through Ethernet, HDMI, 12G-SDI and USB 3.0, Audio In and can be controlled via RS232 & 422 In & Out & IP, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle. The camera tilting and panning speed should be minimum 300° per second. Should support, SRT, FreeD Protocol, PoE and Virtual USB Driver. OEM should be CE, FCC, RoHS & BIS Certified complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 21 Supply, Installation, Testing and Commissioning of Multi-Functional Multi-Camera Controller Joystick should have all required Control Ports complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 22 Supply, Installation, Testing and Commissioning of 4K Video mixer / Speaker Auto Tracking switcher which canseamlessly integrates with above PTZ cameras and conference microphone systems to automatically capture and switch to close-up views of the person speaking, Supports up to 9 Cameras with Automatic Layout Switching, speaker auto-control setting, including override and FIFO modes, customized conference visuals by adding the logo, background images and text overlay for individual speakers, supports 4CH 4K UHD or up to 9CH Full HD video sources,compatible with network-based H.264 RTMP/RTP/RTSP/SRT, and NDI|HX video sources, Video Outputs : 2 x HDMI, 1 x RJ45, Audio I/O : 2 x 3.5 mm stereo Mic in / out complete as per specifications complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 23 Supply, Installation, Testing and Commissioning of 4K Video Recorder, Up to 2ch 4K UHD or 4ch FHD Video Sources Capturing,Switching, Recording and Live Streaming, Support Dante Audio, NDI|HX and SRT Streaming Protocols, PGM Recording up to 4K UHD 30fps with 2TB Internal Storage, Easily Add Background Images, Overlays and Change Video Layouts in Video Making, Supports Overlay PNG Images with Transparent, Opaque, and in Between, Video Input Interface: HDMI x 2, RJ-45 x 2 (supports IP streaming: up to 4 channels, USB x 3 (UVC), Audio Input Interface : 3.5mm Stereo Mic in, Video Output : HDMI x 1 for loop out, HDMI x 1 for preview, Audio out : 1 x 3.5 mm stereo, Recording Mode : 1 mixed + 4 individual original, Control : RS-232 / LAN complete as per specificationcomplete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 24 Supply and Laying of SDI cable complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 25 Supply, Installation Testing & Commissioning of AV over IP 4K Encoder 4K 60 4:4:4with2 x HDMI and 1 x USB-C input and 1 x HDMI output, Auto Video 4K scaler, Switching between the three inputs can beperformedautomaticallyusing auto-switching (input detect) mode, programmatically via a control system, or through a web browser, HDMI loop- through: display any of the three locally connected sources, standard PoE power (15w or lower), HDMI 2.0 & HDCP 2.2, AES-128/256 Encryption, Audio : Analog Stereo 2- channel, HTTPS Secure API, 802.1x Authentication for Network access control, SSH Network Protocol, , Auto Discover all endpoints on the network, VLAN tagging,LLDP Support, QoS Support, USB 2.0 over IP (KVM), RS- 232 over IP, IR over IP, A single Gigabit LAN Port for PoE Power, 4K UHD Video, Latency not more than 10 ms,High Dynamic range(HDR),futureupgradableto Dante / AES 67 complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 26 Supply , Installation, Testing & Commissioning of Decoder supports 4K UHD over Gigabit Ethernet, Bit Rates 50 to 800 Mbps, Video Codec: JPEG2000 based visually lossless video compression algorithm, supports: 4K60 4:4:4, AES-128 Encryption, 1x HDMI with HDCP 2.2 & Sacling Supports a wide range of resolutions and rates, up to 4K, Streaming protocols include IP, UDP, TCP, IGMP, and IGMP, Built-in videowall function, Auto Video Scaler, Vlan Tagging , Analog to digital Conversion: 24 bit, 48 kHz; Control: USB 2.0 over IP (KVM), RS-232 over IP, and CEC over IP, Compliance: CE, FCC, RoHS, WEEE complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 27 SITC of core network switch 24 port 10 G. Efficient use with, 8 SFP+ ports with 10 Gbit,640 Gbps switching capacity, Web interface, Slim 1/ 2 RU housing, Connections – 8 x SFP+ 10 Gbit, 8 x 10G copper. RJ45, RS232, RJ45 Ethernet, 100-240 VAC, approx. 70W, Redundant power supply complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 28 Supply, Installation, Testing and Commissioning of network switch — 24x1G PoE+ Stackable Managed Switch with 2x10GBASE-T and 2xSFP+ (550W PSU) 24-port 1000BASE-T (RJ45) PoE+, 2-port 10GBASE-T (RJ45) all independent, 2-port 10GBASE-X (SFP+) all independent, 128Gbps non-blocking fabric across 28 ports • Out-of-band 1G Ethernet Management port • Mini-USB and RJ45 RS232 console ports and USB storage port, Full L3 feature set and non-stop forwarding (NSF) stacking, Full width form factor with one-unit rack mount kit, one modular 550W PSU in first power supply slot,second slot with a blank cover for future PSU expansion complete with all required accessories needed for sucessful installation and as per direction of Engineer-in-Charge as per requirement of site. 29 Supply, Installation, Testing, and Commissioning of 10G SFP+ modules etc as required. 30 Supply and Laying of 6 core single-mode optic fibre cable in existing casing/ conduit / wall etc complete as required. 31 Supply, Installation, Testing, and Commissioning of 6U AV Rack etc as required. 32 Supply, Installation, Testing, and Commissioning of 42U AV Rack etc as required. 33 Supply and Laying 2m HDMI cable etc as required. 34 Supply, Installation, Testing, and Commissioning of fibre cable accessories etc as required. 35 Supply, Installation, Testing, and Commissioning of AV cable and connector etc as required. 36 Supply and Laying of Cat6 Cable in existing casing/ conduit / wall etc complete as required. 37 Supply and install raceway compartment 100/300 mm x 38 mm, 1.6 mm thick, under-floor metal trunking/raceway with all accessories made from hot-dip pre-galvanized metal-coated steel sheet. With other necessary accessories etc as required. 38 Design, Supply, testing & commissioning of telescopic type MS mounting frame, duly powder coated in custom colour, conference table mounting arrangement for holding iPads for Members, including locking arrangement etc. The mount should have Horizontal/vertical suitable for viewing by the members in the house or as per direction of Engineer in Charge. 39 SITC of Redundancy setup This module allows automatic take-over of the Controller/Server by a spare engine in case one would become inactive. Includes an power switch to facilitate automatic startup of spare engine etc as required. 40 SITC of 20W 2 way column speaker, 3mm aluminum extruded enclosure, sturdy swivel bracket, both direct and LMT connectivity, perforated metal, transducers: 4x2 woofer, 1x1 dome tweeter, input: euro block, sensitivity: 98dB, Nominal impedance: 8 ohm, crossover freq. 6kHz, freq. range: 160Hz~20kHz, Power Taps 100V: 5, 10, 20W, weight: 2.5kg etc as required. 41 (SH:-II Networking system) 42 Supplying, installation, testing and commissioning of Enterprise Grade Core Switch have 24 x 1G/10G/25G Fiber based ports and 4 x 40/100G QSFP+ ports, minimum 1.8 Tbps of switching fabric and minimum 900 Mpps of forwarding rate. minimum 8 GB RAM and minimum 8 GB Flash , Shall have minimum 50K MAC Addresses and 1K VLANs.must have hot swappable 1:1 redundant internal power supply and redundant fan. Must support BGP, VRF, VXLAN, OSPF Routed Access, Policy-Based Routing (PBR), PIM SM, and Virtual Router Redundancy Protocol (VRRP) from Day 1 with 5 Year Warranty 43 Supply, Installation, Testing & Commissioning of SFP+ 100G optical modules for fibre uplinks. Compatible for stacking of Core switches, includes 5 years warranty etc. complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 44 Supplying, installation, testing and commissioning of 24 Port PoE+ Access Switch: 16 x 10/100/1000 Base-T POE+ ports, 8 x multigig copper ports (2.5G/5G/10G) for Wi-Fi-6 APs and 4 x SFP+ uplinks ports and Dedicated/virtual Stacking Port and required cable for Stacking should be considered from Day1, 24 ports should support PoE (802.3af) and PoE+ (802.3at) with a PoE power budget of 370 Watts ,shall have minimum 270 Gbps or more of switching fabric and 210 Mpps (64 byte packet) of forwarding rate ,minimum 2 GB RAM and 4 GB Flash, minimum 16K MAC Addresses and 500 VLANs, should support internal hot-swappable Redundant Power supplies with 5 Year Warranty. 45 Supplying, installation, testing and commissioning of Access Switch NON POE 24 nos. 10/100/1000 Base-T ports. and 4 nos. SFP+ uplinks portsand Dedicated/virtual Stacking Port and required cable for Stacking should be considered from Day1,shall have minimum 128 Gbps or more of switching fabric and 95 Mpps (64 byte packet) of forwarding rate ,minimum 2 GB RAM and 2 GB Flash, minimum 16K MAC Addresses and 500 VLANs, should support internal hot-swappable Redundant Power supplies with 5 Year Warranty. 46 Supplying, installation, testing and commissioning ofWi-Fi 6 Indoor Access Point, MIMO - 4x4:4SS, Min. 2.50 Gbps Aggregate throughput, should support WIDS/WIPS inbuilt, should support BLE/IoT Radio. Interfaces - 1 x 100/1000/2500 Mbps with 05 Yrs of required Licenses and support. 47 Supply, Installation, Testing & Commissioning of SFP+ 10G optical modules for fibre uplinks. Compatible with access/core switches, includes 05 years warranty etc. complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 48 SITC of SDWAN Router supporting minimum 5 Gbps of IPv4 Forwarding throughput and minimum 2Gbps of IPSec throughput, minimum of 8 GB or more Memory and 16 GB or more flash storage, Multi-core x86 processor or better processor and minimum – 2 x 1G/10G SFP+ Wan Ports, 04 x 1G copper ports & should be updgradable if required, USB and RJ45 console Portsincludes 05 years warranty & Licenses etc as per site requirement. 49 Supply, Installation, Testing & Commissioning of UTP Cat 6a S/FTP Cable LSZH etc. in existing casing/ conduit/ wall/ trench etc complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 50 Supply, Installation, Testing & Commissioning of of19 1U straight Un-loaded Patch Panel, 24-portetc. complete as reqd. 51 Supply, Installation, Testing & Commissioning of Shielded Information outletsCategory 6a, EIA/TIA 568-C.2 etc. complete as reqd. 52 Supply, Installation, Testing & CommissioningofSquare Dual Face plate, 86mmx86mm 3x3complete 3 etc. complete as reqd. 53 Supply, Installation, Testing & Commissioning ofmounting patch card Cat 6a S/FTP, 1 meter long, etc. complete as reqd. 54 Supply, Installation, Testing & Commissioning ofmounting patch card Cat 6a S/FTP, 2 meter long,etc. complete as reqd. 55 Supply, Installation, Testing & Commissioning of 6-Core armoured LSZH indoor Multi ModeFiber cable OM4 etc as required. 56 Supply, Installation, Testing & Commissioningof 12 portFibre MMF OM4 Panel RackMountable with Loaded LC adapter plate, pigtails complete etc. complete as reqd. 57 Supply, Installation, Testing & Commissioning of 24 portFibre MMF OM4 Panel RackMountable with Loaded LC adapter plate, pigtails etc. complete as reqd. 58 Supply, Installation, Testing & Commissioning of LC-LC Style MMF OM4Fiber Patch Cord 2 Mtr etc. complete as reqd. 59 Supply, Installation, Testing & Commissioning of 3x3 metalic surface box ISI etc. complete as reqd. 60 Supply, Installation, Testing & Commissioning of Network Rack 9 U wall mount : 600W*600H with Accessories etc. complete as reqd. 61 Supply, Installation, Testing & Commissioning of Network Rack 12 U wall mount : 600W*600H with Accessories etc. complete as reqd. 62 Supply, Installation, Testing & Commissioning of Network Rack 27 U with below included: Network Rack 800W x800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs etc. complete as reqd. 63 Supply, Installation, Testing & Commissioning of Network Rack 42 U with below included: Network Rack 800W x 2000H x 800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs, 42 U 19 Profile Typeangle, Front Rack Type 1-800W X 2000(42U)H X 1000Detc. complete as reqd. 64 Supply, Installation, Testing & Commissioningof1U Cable Manager Horizontal Single sided etc. complete as reqd. 65 Supply, Installation, Testing & Commissioning of 3 KVA UPS 0.90 input power factorfeatures. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Single Phase Input and Single Phase Output. ( Input - 220V - 250V, Single Phase, 2 wire. / Output - 200Volt, Single Phase, 2 Wire.)Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be internal type and suitable for 30 minute backup on 100% load etc. complete as reqd. 66 SITC of 10 KVA UPS 0.90 input power factorfeatures. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Single Phase Input and Single Phase Output. ( Input - 220V - 250V, Single Phase, 2 wire. / Output - 200Volt, Single Phase, 2 Wire.)Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be internal type and suitable for 30 minute backup on 100% load etc. complete as reqd. 67 Supply, Installation, Testing & Commissioning ofWater Leakage Detection System etc. complete as reqd. 68 Supply, Installation, Testing & Commissioning ofRodent control system etc. complete as reqd. 69 Supply, Installation, Testing & Commissioning ofSteel Cement Laminated Raised Floor, Size (mm): 600x600 35mm etc. complete as reqd. 70 Supply, Installation, Testing & Commissioning of Door access control system etc. complete as reqd. 71 Supplying and Fixing following sizes DLP PVC adaptable trunking system for laying of wires for various services complete with accessories such as angle and end cap, Junction, Jointetc. complete as required. 72 32 x 12.5 73 32 x 16 74 32 X 20 mm 75 80 X 50 mm 76 105 X 50 mm 77 150 X 50 mm 78 195 X 50 mm 79 Supplying & Laying of one number XLPE insulated stranded copper armoured power cable of 1.1 KV grade of following size in existing casing/ conduit/ tray/ wall/ Race ways / ductetc as complete asper attached specifications and as per direction of Engineer in Charge as per site requirement.a) 3 core 4 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
36.
Defence #10003682 AOC
Tender For Demolition And Re-Construction Of Smc Building At Afs Yelahanka On Epc Mode; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX are prepriced by MES under Ser No. 2 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Site Clearance as listed in Schedule ‘A’ Part - II. 4 Lumpsum price worked out by the contractor for Road/Path/Hardstanding as listed in Schedule ‘A’ Part - III. 5 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - IV. 6 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. 7 Lumpsum price worked out by the contractor for “Fencing” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII 9 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII 10 Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – IX 11 Sch A Part - I : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF TWO STOREY (G+1)SMC BUILDING, AMBULANCE PARKING SHED AND DEMONSTRATION AREA INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. 12 SCHEDULE A Part- X (FITTINGS AND FIXTURES & MISC ITEMS) 13 ROADMaterial and labour for preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using HOT MARK by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4of MORTH specification,thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088Aand road marking shall done as per provisions contained in IRC-35-1997 complete all as specified and as directed. 14 FENCINGSupply and fix Stainless steel 304, 12 inch size each letter for Bilingual name board (Hindi-14 Nos letters and English-21 Nos letters) embedded in Granite on both gate complete all as specified and directed. 15 EXTERNAL WATER SUPPLYMaterial and labour for cutting existing 150mm bore water mains and inserting TEE 150mm x 100mm including necessary fittings, joints etc for connection of TEE complete all as specified and as directed. 16 Supply and fix Cast iron sluice valve flanged of class 1.0 PN, 80mm complete all as specified and as directed, 17 Supply and fix 80 mm dia cast iron body with flanged ends drilled ISI marked as per IS 14846:2000, PN 1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and as directed. 18 EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 19 Material and labour for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and directed. 20 Supply and installation , testing and commissioning of HT 11 KV, rated voltage 12 KV,630 Amp, 21 KA / 3 Sec outdoor type extensible internal arc 21 KA for 1 sec for Tank floor mounted with internal copper busbar, SF6 insulated completely motorized 4 way RMU consisting of 01 Nos VCB 630 Amps as incomer and 03 No 630 Amp VCB as outgoingSCADA compatible, over load and earth fault protection relaywith air insulated metering module (MFM for VCB feeders) all live parts busbar ,VCB connections of RMU shall be inclusive in one SF6 tank to avoid multiple inter connections SF6 tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel grand 304 min 2.5 mm thick having IP-67 degree of protection filled with SF6 gas has insulation with leakage rate less than 0.1% per year tested as per IEC 62271 200 I No fault passage indicator (FPI) required for complete unit manual welding or heremetic ceiling of tank shall be not accepted . The unit shall have front cable entry (suitable for termination of 1 hr x 3C 95.120/ 150 Sqmm cable) for easy of installation and shall have site replaceable bushing for easy of troubleshooting during break down. RMU should be completed with all accessories such as terminal boots, VPIS , cable supports , all front cable terminations , mechanical indications vacuum circuit breakersON/OFF, Manometer as per with IEC standards 62271200, 60056, 60129, 60265, 60298, 60420, 60529 & 60694 altitude of installation upto 1000 m as per IEC 60120bushing bolted type top monitored outside the tank for connections of external busbar also the outer includes shall cover the full length of the switchgear , to ensure IP3X + IP-54 protection for cable boxes the unit shall be internal arc proof 24 KA for 1 sec with AFLR classification tested and totally safe for human being. 21 The gas release and personnel safety from internal arc shall not dropped on plinth design the release of gas to be from the top the unit . So that even if the person is operating the unit opening the cover and there are personnel near the side of the RMU / plinth top release will ensure their safety. The hot gas release in case of an internal arc, in No of case should be from any side or bottom of the unit as the same if unsafe for operating personnel / pedestrian or general public. Bidder shall provide type test report to be prove compliance to the internal arc fault IAC-AFLR as per IEC62271-200 internal arc testing shall be done with enclosure door in open conditions , with switching devise in operations mode as per specified standard RMU.(a) 01 Nos Incoming 630 AmpsVCB,motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 Nos Outgoing 630 Amps motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.(c) Bus connected PT unit-01 No for metering consisting of following:- (i) Type M : Air insulated metering module 12 KV, 630 A 21 KA for 3 sec.(ii) 3 voltage transformers of the ratio 11KV/1.732/110V/1.732.25VA class 1.0 with HT fuses on primary side and MCB on secondary side. 22 (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVAR.(iv) 1 LED bulb for illumination. (v) 1 Space heater with thermostat. (vi) 1 RYB Phase indicator. (vii) 1Cable support bus bar, stand for 3 Way unit, 1 Manometer & 1 Preparing Handle. (viii)1 Set bushing for external busbar connection along with bus bar cover & sleeved bus bars for coupling. (ix) 2x12 V Battery with charger of suitable burden for motor operation, input 230 V AC & output 24 V DC.(d)Capacitive Voltage indicator fixed type VPIS 9-15 KV. (e) Necessary inter locking arrangement for safety and operation. (f)One No Operating handle for manual operation. (g) PCC 1:2:4 type B1 using 20mm graded stone aggregate for foundation and bus duct of cable for RMU as per recommendation of manufactures & as directed by Engineer-in-charge. (h) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (j) Above switchgears shall confirm to all relevant IEC/IS standard.(k) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be required to dismantle during manual operation.(l) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable.(m) Minimum 3 Module should be accommodate in one tank to avoid multiple coupling at site. (n)Having following additional facilities:-1. Trip circuit supervision. 2. Disturbance recorder. 3. Event log with date and time.4. Measurement and control feature. 23 (o) Current Transformers (CTs) of dual ratio 50/25-5A of 15 VA output, accuracy class 1.0 for metering instrument and 5P10 for 15 VA accuracy for over current and earth fault protection - sets of 03 Note:-(i) Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.(ii)Cable compartment shall be provided at the front side with front bolted type box covers providedwith an inspection window forenabling operator to have visual inspection without operating cover in live condition for all incoming and outgoing RMU panels.(iii) Complete with internal and external connection with each other or as per ground requirement.(iv) Drawing and Design drawing shall be submitted for approval of Accepting Officer before placing Order.Following additional equipment delivered separately or mounted in respective panel.(i) Cable support bars, standard for 4-Way unit.(ii) Manometer.(iii) Operating handle. 24 Supply and fix 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required andall as specified and directed. complete accessories as required complete all as specified and as directed. 25 Supply and fix street light fitting 72 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection including GI Bracket of suitable size required for fixing LED light on pole along with nut and clamp complete all as specified and directed.Note :- Rates quoted by contractor are deemed to be inclusive of 3 core cable pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified. 26 Supply and fix pole box of size 450x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp02 Nos with nuts, bolts and washers complete all as specified and as directed. 27 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point including testing on completion complete all as specified and as directed.Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. including testing on completion complete all as specified and as directed. Note :(i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode.The earth pit and pipe for watering shall be provided in slanting manner.The unit rate include for GI pipes, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item. 29 Supply, installation, commissioning and testing of feeder pillar board Kiosk type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proofand compartmentalizedMain L.T Panel(CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 900 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.)Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators.All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves ofcoloured coded red, yellow, blue & black. Power & Control Wiring withCopper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Platform for the feeder pillar board with PCC 1:2:4type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minimum 100mm all around the feeder pillar board with following :- 30 (a)ACB 415 Volts, 630 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release -01 No.(I/C)(b) MCCB 415 Volts , 250 Amp 4P , 36 KA ,microprocessor release - 01 Nos (c)MCCB 415 Volts , 160 Amp 4P , 25 KA ,microprocessor release - 02 Nos(d) MCCB 415 Volts , 125 Amp 4P , 25 KA ,microprocessor release - 02 Nos(e)MCB415 Volts , 32 Amp 2P , 10 KA ,microprocessor release - 02 Nos(f)Voltmeter 0-500V digital type with selector switch 96mmx96mm square flush mounted- 01 No.(g)ampere meter digital type of size 96mmx96mm flush mounted CTs operated including CTs 0-630A with selector switch-01 No.(h) LED type/Neon type indicating lamps panel mounting type RYB-03 Nos.(i)fine wiring with single core PVC insulated conductor FLRS wire of suitable size copper conductor cable,thimble, lugs etc for instruments/indicating lamps-01Job. 31 Supply, fixing, testing & commissioning of LT panel board of size 1.1x1.1x.5 Mtr,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closedAluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltmeter 0-500 Volts, CTs of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc The bottom portion of enclosure shall be minimum 100 cm above ground level of legs of angle iron ). 32 (a) Copper bus bar capacity 900 Amps for Phase-R-Y-B-3 Nos &neutral -1 No(b) ACB FP 36 KA 630 Amps- 1 Nos(I/C) (f) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-630 Amps (g) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V(h) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder 33 Supply and fix Post top light of capacity 45Watt offering excellent uniform illumination and aesthetic in one go , made up of pressure die cast aluminium body and open PC Cover, IP 66 and IK-07 rating suitable for tall amid varied environmental conditions and for pole of dia 76mm colour temp 3000K complete all as specified and directed. 34 Supply and fix LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 9W, 220V, 50 Hz CCT- 3000K, 800mm Complete all as specified and as directed. 35 Supply, erection, testing and commissioning of 16M high mast shaft in two section suitable for 44m/sec wind speed along with head frame, luminaries carriage suitable for 8 luminaries in symmetrical arrangement and other accessories manufactured in factory including Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaries & MCB in base compartment are not included and are a part of installation) complete all as specified and directed by the Engr-in-Charge. 36 Supply of fix single dome LED type dome aviation obstruction light complete all specified and directed by Engr-in-Charge. Make : Bajaj Cat No : BGAV302LED or its equivalent in make specified in PS. 37 Supply and fix foundation bolts 04 Nos 24mm dia 850mm length, manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 38 Supply and fix LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed by Engr-in-Charge. 39 DG SETSupply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 320 KVA, 3 phase 0.8 power factor, 50 Hz,developing 434 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Yelahanka and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration andincluding the following accessories :-Make : Kirloskar / Ashok Leyland/ Ruston/Cummins 40 (A) Alternator :-Synchronous alternator rated at 320 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-(a)+-1% voltage regulation (max) in static conditions.(b)IP: 23 protections with class ‘H’ insulation. · (c)Permanent lubricating bearing. · (d)Permissible overload of 10% for one hour in 12 hours of operation.(B) Diesel Engine: - Adquate capacity of Diesel engineliquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Liquid pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential typev) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hosesvi) Lub oil System :- Lubricating oil filter,Lubricating oil pumpvii) Air Intake System :- Air intake Manifold,Air cleaner dry typeviii) Governer : Electronic typeix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length fromself starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. 41 xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure,high coolant temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Base frame is fabricated either in ISMCor in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete seti.e. along with canopy, engine and alternator.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines.xviii) 2 No battery of 12 V in charged condition with its leads. C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. 42 (i)Manufactured by OEM suitable for 320 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistancefoam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be < 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade.D) Control Panel :- Control panel shall befabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.(ii) Instrument fuses and control wiring. (iii) Indication lampsset for running and load on.(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. 43 E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. F) Civil Works :-All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint workand related foundationsfor panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.The contractor shall arrangeartificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system toachieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved fromEngr-in-charge/GE before placing final order to the manufacturer.vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set. 44 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion.Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 45 REFRIGERATION & AIR CONDITIONING:-Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star ratingAs perBEE guidelines and ISEERValue not less than 3.90 for air conditionerof capacity 1.5 TR includingall specified and directed by Engr-in-Charge. 46 Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating as perBEE guidelines and ISEERValue 3.95 for air conditionerof capacity 2 TR complete all specified and directed by Engr-in-Charge 47 Supply, fixing, jointing and testing copper tubing with nominal diameter1-1/4 inch ofthickness not less than 1.2mmfor liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 48 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 49 Material and Labour for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enameled black paint complete all as specified and directed by Engr-in-Charge. 50 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 51 HAND DRIER AND SOAP DISPENSERSupply and fix automatic hand drier machine suitable for single phase supply 230 Volts, 50 Hzwith ABS plastic body complete all as specified and directed. 52 Supply and fix automatic soap dispenser , 220 V , 50 Hz complete all as specified and directed. 53 UPSSupply, installation, testing and commissioning of online UPS of 30 KVA with isolation transformer and static bypass switch, Authomatic transfer switch of capacity 100 Amps 4 Pole) alongwith required sealed maintenance free batteries and batteries (12V 100 AH-32 Nos)with stand for backup of 30 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete as required.I/P Voltage 360 V - 480 VNominal frequency - 50 HzFrequency range for online operation 45-50 HzI/P current range - 36A - 29AO/P voltage 415 VO/P current - 42A 54 LIGHTNING PROTECTIONSupply & fix Special standing seam fixure Clamp for Air terminal on Metal Structure -Site specific all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICT54 or its equivalent in approved make. 55 Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIAT02JIM04 or its equivalent in approved make. 56 Supply & fix 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIDC01 or its equivalent in approved make. 57 Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make JEF Cat No JIDC01 or approved by E-in-C Branch/CE Southern Command.Make : TIRUMALA/JEF Cat No JICL07 or its equivalent in approved make. 58 Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICL49 or its equivalent in approved make. 59 Supply & fix Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP02 or its equivalent in approved make. 60 Supply & fix Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JISP01 or its equivalent in approved make. 61 Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP05 or its equivalent in approved make. 62 Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connectRound to Flatconductor all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No TL06 or its equivalent in approved make. 63 Supply & fix Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No R14.CB1.SS01.E06 or its equivalent in approved make. 64 Suply & fix25 X 6 mm size GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding all as specified and directed by Engr-in-ChargeMake : TIRUMALA/JEF Cat No DW16 or its equivalent in approved make. 65 Supply & fix Holder -GI for fixing 25x 6 mm GI Strip complete all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFNo JICL08 or its equivalent in approved make. 66 MEDICAL GAS PIPE LINE SYSTEMSupply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :12mm X 0.7 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 67 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :15mm X 0.9 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 68 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :22x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 69 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :28 x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 70 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor oxygen complete all as specified and as directed. 71 Supply and fix Humidfier bottle forBPC flow meter complete all as specified and as directed. 72 Supply and fix Metal body BPC flow meter (0-15 ltrs ) adult complete all as specified and as directed. 73 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor vacume complete all as specified and as directed. 74 Supply and fix 600 ML VACUUMEJar complete all as specified and as directed. 75 Supply and fix Vacummer regulator complete all as specified and as directed. 76 Supply and fix Zonal valve box completeset withisolationballvalve and gauge (Aluminium framewith MSBox for2services (15mmx 22mm) complete all as specified and as directed. 77 Supply and fix Microprocessor based line pressurealarmdigitaltypefor2 gas serivce(oxygen / vacumm) complete all as specified and as directed. 78 Material and labour for perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar / Super Steel Industry / SV metals Pvt Ltd 79 DEMOLITION OF EXISTING BUILDINS (E/M ITEMS)Taking down unserviceble submain wiring any size /any cap complete all as specified and as directed. 80 Taking down unserviceble DBs any size / any cap complete all as specified and as directed. 81 Taking down unservicebleMCB SP/SPN any size /any cap complete all as specified and as directed. 82 Taking up old earthing any size/any type complete all as specified and as directed. 83 Takingdown earth strip/wire any size/any type complete all as specified and as directed. 84 Dismantling and taking out carefully GI pipe 25mmdia including earth work/RCC and complete all as specified and directed Engr -in-Charge.
Contract Date: May 26, 2026 Contract Value : 11.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
37.
Educational and Research Institute #10000242 AOC
Tender For Construction Of Ctvs Transplant Ward In Aiims Raipur; 1 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 2 Centering and shuttering including strutting, propping etc. and removal of form for 3 Lintels, beams, plinth beams, girders, bressumers and cantilevers 4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5 Thermo-Mechanically Treated bars of grade Fe-500D or more. 6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 7 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. 8 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 9 Providing and fixing 15-17 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirtings and similar locations of required size, approved shade, colour and texture laid with epoxy resin based adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, cleaning, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red and any size: 10 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 11 40 mm 12 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 13 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 14 250x16 mm 15 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 16 200x10 mm 17 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 18 Twin rubber stopper 19 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 20 Double strip (horizontal type) 21 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 22 Providing and fixing to existing door frames. 23 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 24 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 25 100mm 26 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineerin- charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 27 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge 28 200 mm 29 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. 30 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 32 Size of Tile 600x600 mm 33 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 34 110 mm diameter 35 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc., wherever required. 36 Main ‘T’ runners to be suspended from ceilingusing G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted withpolyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 37 12 mm cement plaster of mix : 38 1:6 (1 cement: 6 fine sand) 39 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 40 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 41 Two coats 42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 43 In cement mortar 44 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 45 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 46 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 47 W.C. pan with ISI marked white solid plastic seat and lid 48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 49 White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap 50 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 51 Size 600x450x200 mm 52 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 53 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 54 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 55 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. 57 50 mm nominal dia Pipes 58 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 59 20 mm nominal dia Pipes 60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 61 25 to 40 mm nominal bore 62 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 63 20 mm nominal bore 64 Providing and fixing uplasticised PVC connection pipe with brass unions : 65 45 cm length, 15 mm nominal bore 66 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 67 15 mm nominal bore 68 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 69 15mm nominal bore 70 Providing and fixing PTMT grating of approved quality and colour. 71 Circular type 100 mm nominal dia 72 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 73 For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) 74 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron) 75 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. 76 Pre-laminated particle board with decorative laminationon both sides 77 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketn etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 78 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) 79 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 80 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixedm with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 81 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : 82 Providing and fixing in position Double bay stainless steel (304 grade) scrub station of size 1220x610x1500 mm with automatic sensor & foot operated tap with hot and cold water temperature controller valve and foot operated soap dispenser arrangement of approved make and quality as per the direction of engineer in charge. 83 Providing and fixing 44 mm thick HPL (Hinge Pressure Laminate ) Hermetic Hinge single Leaf Door for civil opening 1800(W)x2100 (H) with S.S. Ball bearing hinges , D Handles , both side key operation dead lock ,View window size 300x300 mm ,sealing gasket, Automatic Drop seal ,door seal and one door closer etc. all complete as per instructions of Engineer In charge. 84 Providing and fixing frosted film of make 3M/Avery/Oracal and of thickness not less than 1 mm over the glass of windows, glass partition etc including cutting of film in a certain design, shape all complete as per the instructions of Engineer In charge. 85 Providing and applying anti microbial epoxy PU flooring of thickness not less than 3 mm, in required colour, patterns etc. having anti skid properties,corners should be uniformly curved, final surface should be non corrosive to biological fluids, detergents etc. all complete as per the instructions of Engineer In charge. The execution of item shall involve activities of cleaning the surface, grinding of the cleaned surface by manual or mechanical means, applying PU flooring primer on the complete surface followed by screed activity to level the complete surface and then followed by applying PU Topcoat. The items to be used shall be of make BASF/ENDURA/MYK failing which the make approved by Engineer-in Charge shall be used. The work is to be executed and completed all as per manufacturers specification and as per direction of Engineer-in Charge. 86 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 88 Using M.S. angels 40x40x6 mm for diagonal braces 89 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 90 In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete 91 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 92 10 x 120 mm 93 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 94 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) 95 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. 96 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 97 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 98 Providing and fixing 50 mm thick galvanised Puf panel of make Jindal/Tata/JSW on the walls and roof (size, shape and pitch of corrugation as approved by Engineer-in-charge) . The sheet shall be fixed using self drilling /self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,including cutting to size and shape wherever required, Fixing operations of roof/wall panels shall be completed in all respect as per drawings and manufacturers specifications and under the overall direction of the Engineer-in-charge.Drawing and Layout of Puf Panel is to be submitted by the contractor for the approval of Engineer-in Charge. No separate amount is to be paid by the department to the contractor for drawing/layout 99 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit & accessories as required. 100 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 101 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 102 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 103 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 104 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 105 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 106 5/6 A switch 107 15/16 A switch 108 3 pin 5/6 A socket outlet 109 6 pin 15/16 A socket outlet 110 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 111 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 112 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 113 1 or 2 Module (75mmX75mm) 114 3 Module (100mmX75mm) 115 4 Module (125mmX75mm) 116 6 Module (200mmX75mm) 117 8 Module 118 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 119 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 120 1 run of cable 121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 122 100 A,30KA,FPMCCB 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 124 6 way (4 + 18), Double door 125 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 126 Single pole 127 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 128 63 A 129 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 130 63 A TP&N MCB 131 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 132 For 6 way, Double door TPN MCBDB 133 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 134 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). 135 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required. 136 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 137 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 138 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 139 40 A 140 Supply and laying of3.5*50 Sqmm 1.1 kV grade PVC Sheathed XLPE insulated aluminium armoured cable. 141 Supply and Installation of Exhaust fan suitable for single phase, 230 volts, 50 Hz, AC supply having RPM 1100or better , 300 mm sweep, power input = 35W or less, Air delievery ≥ 700 CFM complete with motor, louvers/ shutters etc. as required in the existing window, includes dismembering of window glass, providing and fixing ACP panel (6mm thickness Aluminium composite panel) framing in place of glass, connection, testing, commissioning etc. as required. 142 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 143 18 watt 144 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 145 36 watt 146 Supplying and Installation of clean room recess mounted 600X600 mm, 30-34 watt LED luminaries with lumen efficiancy of >100 lm/W, dimming option, highly specular anodized aluminum reflectors, optical antiglare system, high effiency polycarbonate diffuser with EMC/EMI compliant electronic driver having PF>0.9, THD < 10%, & minimum of 3kV surge/burst protection, complete with 50000 hrs burning for lifetime with supporting data sheet LM-79 & LM-80. Luminaries cover should be made of highly resistant, disinfectant proof laminated, safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The Recess frames should be gas tight. The white luminaries body should be made of sheet steel, perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear in multilamp technology. The Light fitting should be flush with the ceiling and should be removable from top or bottom. Optional pre-set color temperatures or adjust to any CCT in the Productivity Range 3000 K - 5700 K, Dimming Range 10%-100%The LED used in the luminaire shall be only Lumileds, Nichia, Cree, osram & LGIT and hanging with necessary chain etc as required. 147 Supply and Installation of 10 litre capacity Water Geysers in required locationequivalent to Jaquar model- EPM-WHT-V010* 10 liter capacity* Temperature Range:- 25-70ºC or better* Wattage:- 2KW or less* 5 star rating* suitable for single phase, 230 volts, 50 Hz, AC supply. 148 Supplying and Installation of 60 mm thick hermetically sealed single sliding door of ( 2.1 m (H) x 1.5m (W))/(2.1 m (H) x 1.8m (W)). The controller should be capable of being operated by elbow switches/ foot switches as well as touch less sensor. The track should be of Stainless steel/ Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door material should be of HPL colour should match the interior and care should be taken to make the leaf strong and light weight.The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/ Aluminum track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. One should be able to open and close the door effortlessly in case of failure of automatic mechanism. Door opening handle should be of SS (gloss finish), i/c high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing, Air tightness 99.99% at a pressure of 100KPa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be of 60mm. The inner part of the door should be filled with CFC free polyurethane foam. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. All motors used should be DC brushless motors with essentíal isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed motorized roller blind inside. The starting time after receiving the signal shauld be adjustable between 0.5 to 20 seconds. The complete door assembly should be BIS/ European CE marked/ US FDA approved. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.Hermatically Sealed HPL finish DOOR - Automatic with automation,Supply, Installation, Testing of automatic sliding hermatically OT door size of with Double sided wall frame with HPL Plank 400mm.1- Door Profiles- Aluminium Alloy, Grade 6063, Temper T6. Natural Anodized 20 μm.2-PIR. Dimensional stability at +100°C & -25°C (2%max).Density 41Kg/M3 with max deviation of 2kg/m3 as perDIN53420.3- Door Skin- HPL (4mm) both side of door4- Sealing Gasket (Sides and Top)- Replaceable Bulb and Lip design EPDM gasket.5- Sealing Gasket(Bottom)- .Replaceable Special lower sealing EPDM gasket.6-. Vision Panel- Double Glazed IG unit with 5mm tempered glass on both sides. Size = 300 mm x 300 mm x 60mm.7-Lever Handle- Solid AISI 304 Grade Stainless Steel with rubber spring system.8- Rail System- 6mm deep indentations with ‘down and in’ movement at the angle of 45⁰.9- Rollers- Special Grade Self-lubricating PA Bearings: 2X per roller.10-Wall Frame- Aluminium Alloy, Grade 6063, Temper T6 Natural Anodized 20 μm.11- Planks- HPL Planks finished with compact laminates are used to cover the door opening.12- Noise Insulation-28 dB.13- Air Permeability- Air Leakage at ± 100 Pa (pressure difference) = 0.07 m³/h.m. 1-Microprocessor Based controller. (230 Vac, 750 W (max),2- motor, IP65 protection Class, 20 Nm, 3Øx230V. (CE Marked).3- If an obstruction is present and prevents the door from closing, the intelligent automation sense with self reversal function thus eliminatingthe need for an ugly safety strip.4- Additional safety is provided by means of a photo cell fitted across the door opening.5- Variable options for the opening and closing speeds, time delay closing and part opening for pedestrian use and are easy to adjust.6- A self diagnostic coded system makes fault finding simple, reducing expensive down time.7- Magic (Hand) Switch- The spread of infection is controlled by automating the doors with touch less sensors allowing hands free operation.8- Foot switch or Elbow Switch- AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors.Control: Microprocessor-controlled with Deceleration Measurement System sliding door drive.Power supply: 230 Vac +10% / -15%. Frequency: 47-63Hz . Power Consumption -Maximum : 750 W.Drive :STG motor. Nominal Motor power:90 W, High Torque Motor -20Nm.Microprocessor controlled motor driver. Max. door weight : 350 Kg.Adjustable Speed Control level: 1-9 . Slow speed (V slow) :20(Threshold speed) - 120 mm. / sec.Starting speed (V start) :20(Threshold spped) - 220 mm. / sec. Opening speed (V open) :Threshold speed to 800 mm. / sec. Closing speed (Vclose):Threshold speed to 400 mm. / sec.Pedestrian opening (Half Opening width) :10% - 99% of the available door opening. 149 Supply ,Installation,Testing & Commissioning of factory built cabinet type unit withAl anodised thermal break frame structure injected with minimum 45+-5 mm thick PUFinsulation, GIPanelshallbepowdercoatedfrombothinnerandouterside,evaporationDxcoil expansion valve and corded remote ,Fan section with double width double inlet (DIDW backwards curved) centrifugal fan with Variable speed Fan Motor with VFD, prefilter section with EU3 / G4 class filters & EU-7 Filter(As per Approval of Engineer Incharge ) Dx coil.units shall be with a remote controller as per site requirement. Rating for the AHUs shall be as under - Motor selection (IE-3) to suit the below capacity AHU ratings. AHU shall be mounted on floor/Ceiling Mounted with vibration isolatorsUnit shall be with factory fitted inlet/outlet aluminium Aerofoil dampers. ,Temperature controller ,Door open switch ,pressure drop across filters ,Fan motor over load protector ,Suitable UV System Chamber complete with cable /wiring etc. will be part of this AHU Unit. AHUShouldhave1setofSpareFiltersapartfromCommissioningfiltersfixedinAHU. SuitableCommunication cable from indoor to outdoor is in the scope of agency .Double Skin Heater Bank Chamber comprising of SS 304 spiral strip heaters fitted with Porcelene blocks, Safety air stat & access door for heater rating , UVGI Lamp etc. As per per approved design from Engineer Incharge. AHU connection Kit with Control box (expansion valve ), Control Box,Nitrogen Testing ,Vaccuming , Green Refrigerant Top up .It should be equiped with Controler to control humidity up to 55 % (+-5%).AHU Machine should be Equipped withmotorised Fire Dampers .F.M./S.A Fan 4000 CFM /18 TR(24 HP) X 2 Numbers Coils / 6 ROW coil Full Copper , with two Stage Filter level 10 micron + 5 Micron,ESP-150 MM in WC. Design parameter- Temp.-21+-3 Degree Centigrade , Relative Humidity -55+-5% 150 Supply, Installation, Testing & Commissioning of 22 HP modular type variable refrigerant flow / Variable regrigerant Volume air cooled outdoor units suitable for cooling and heating having all hermatically sealed inverter type scroll compressor, minimum two compressor for above 14 HP modules, microprocessor based controller,top discharge type condensing units, with R410 A refrigerant, Vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Celcius ambient temperature without tripping. The unit shall be suitable to work on 400+/-10%, 3phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required with suitable communication cable. The COP at AHRI Conditions shall not be less than 3.1 and IEER not less than 6.5. 151 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 152 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 153 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 154 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 155 Supply, installation, balancing and commissioning of Site fabricated Aluminium 0.80 mm rectangular/Circularducting as requiredwith supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr) includes cutting/ dismanteling of wall (if required) and make good the same.Note: Fabrication and jointing of duct shall be as per IS standard and hanging shall be as per SMACNA. 156 Thickness 0.80 mm sheet 157 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. 158 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 159 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 160 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. 161 Fire Damper 162 Actuator 163 Supply and fixing of acoustic lining of AHU wall and ceiling with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to wall and ceiling with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 164 Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 165 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Drainage. 166 32 mm nominal dia. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit,fitting as required. 168 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 169 Supply ,Fixing and erection of Duct rexin Fire Retardent Canvass Connections with Vibration & Isolation Pad complete as required . 170 Supplying and fixing of MS of (40X40X5)mm stand for condensing (Outdoor) with epoxy painting, unit Size - 1040 mm(L)*440mm(W)*300(H)} . 171 8 SWG (Copper ) Earthing Cable Supply & Fixing complete as required . 172 Supply and fixing of 10 mm Open cellacoustic insulation of supply air duct and plenum with fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per direction of Engineer Incharge AIIMS Raipur. 173 Supplying, fixing, testing and commissioning of Hepa Filter of required Specification withincluding making arrangement for fixing complete as required and as per direction of Engineer-in-charge.Class-14,Efficiency -99.97 174 Supplying, fixing, testing and commissioning of 1 Tile Membrane Surgeon Control Panel of following Specification including making arrangement for fixing with necessary acessaries ,Cable etc. complete as required and as per direction of Engineer-in-charge. 175 Supplying, fixing, testing and commissioningofmotorised damper as required Specification withnecessaryarrangementas per direction of Engineer-in-charge. 176 Supply and fixing ofinsulation work with 6 mm nitrile rubber on existing CPVC drain pipe(32 MM) properly as required. 177 Supply, Installation and Testing of G I Sheet with Galvanized Coating cable tray cover for 225 mm powder coating M.S. cable trays it is highly durable and robust , corrosion and can sustain high load andincluding bolts & nutsall accessories as per specifications etc. as required. 178 Supplying, installation, testing and commissioning of M.V/LT. cubical type totally enclosed dust and vermin proof Floor/Wall mounted Sub Main Distribution Boards suitable for use on 430 V 3 phase 4 wire 50 Hz AC supply, having compartmentalized construction for different incoming/outgoing MCCBs from Approved Make, and separate bus bar & cable alleys , fabricated from min 1.6mm thick CRCA sheet steel of uniform width complete with copper bus bars , MV/LT danger notice plate, Digital type ammeter with Ammeter selector switch , voltmeter with Voltmeter selector switch , LED indicating lamps, cast resin CTs , Confirms to IEC-61439-2, IP-43, Interconnection with suitable capacity copper strips / rods, connection of incoming and outgoing cables with thimbles , smoke/Siemens grey colour stove enamelled painted and having following incoming and outgoing switchgears, 2 earth bolt, removable cable gland plate with spare suitable hole, wall/floor mounted, lockable using hollow standard LT Panel lock key complete as per site required or as approved by Engineer In-charge. A. INCOMER 01 nos. 250amps 35kA TPNL MCCB from Approved Make Thermo-magnetic release type with rotary handle. 01 nos. Digital type single function volt meter to show 0-500V voltage with phase selector switch01 nos. Digital type single function ameter to show amperage with phase selector switch 03 Nos Energy Meter 03 Nos CTs 125/5 ratio 03 LED Indication Light with toggle switches B. OUTGOING 08nos. 40A TPNL MCCB (25 KA) Thermo-magnetic release type. 179 Dismentlingwork of Existing installed duct, FCU, HVAC Pipelines, Starter Panelincluding Welding, Cutting as required as per direction of Engineer Incharge AIIMS Raipur. 180 Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying,installation,testing&commissioningofmanualcallboxesofMS constructionin surface/recesswithstainlesssteelchain&hammerassembly complete with glass and push button etc. as required. 182 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 184 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered along with battery arrangement for power backup complete with all connections, interconnections as required. 185 4 Zone 186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 187 Supply and fixing of 4 kg clean agent (HCFC) portable fire extinguisher having pressure guage indicator and arrangement for wall hangingand with warranty for 5 years on complete product. 188 Providing and fixing you are here sign board near entrance and fire reflective sign board, reflective stickers signage for indication at fire doors, fire extinguisher, fire exit with suitable size as per requirement and as per instruction from Engineer In-charge.
Contract Date: Apr 16, 2026 Contract Value : 1.09 Crore
Government Departments No of Bidders 4
Chhattisgarh View Result →
38.
Petroleum and Natural Gas #9994988 AOC
Bids Are Invited For Custom Bid For Services - Amc Of Rosov Installed At Bpcl Muzaffarpur Depot Repair and Overhauling Service Operation And Maintenance Of Electro-Mechanical Installations Repair, Maintenance and Installation of Plant/ Systems/Equipments i. Visual inspection of the actuator and control panel for any abnormalities or physical damage ii. Checking the open and close operation of the actuator by energizing and deenergizing solenoid valves (from local and remote push button station) iii. Checking the Emergency Shutdown (ESD) operation iv. Checking Limit switch and ensuring proper feedback / indication v. Checking of Solenoid valve function vi. Checking of Air filter regulator vii. Checking of flow control valve viii. Checking of control panel piping, tubing and ensuring proper tightness of all fittings ix. Checking of air leakage on the actuator and control panel x. Checking of mechanical indicator in limit switch box xi. Checking of Limit switch box sealing xii. Checking of grease/oil leakage & Top up grease/oil if required xiii. Replacing O rings and seals/oil seals if required xiv. Replacing faulty parts if required xv. Checking tightness of all fasteners including actuator mounting on the valve xvi. Ensuring smooth operation of the actuator xvii. Data log download and analysis of log report from pervious report to determine actuator healthiness. xviii. Any other Preventive maintenance activity required for ensuring 100% breakdown free operation. Total Quantity :
Contract Date: Ref. Documents Contract Value : 2.51 Lakh
Boards / Undertakings / PSU No of Bidders 3
39.
Defence #9990832 AOC
Bids Are invited for Structuhral Audit Of Bldgs 1A - Conducting Structural Audit For Rehabilitation For The Building Nos P35 Uro Approx Total Plinth Area 33 Sqm Which Includes Following Visual Survey Visual Inspection For Surface Damages Damage Classification The Visual Inspection Shall Largely Cover Areas Of High Distress Corrosion Moisture Leakage Abnormal Variations In Structure Algae And Fungus Growth Efflorescence Etc Visual Inspection Would Be Documented In The Form Of Worksheets Photographic Records And Distress Over Drawings Simple Tools And Instruments Like Camera With Flash Light Magnifying Glass Binoculars Chisel And Hammer Etc Shall Be Used For Measiring The Distresses As Per Site Requirement , Structuhral Audit Of Bldgs 1B - Rebound Hammer Test Nos Of Tests 4 For Determining The Estimated Compressie Strength Of Concrete And Iniformity Of Concrete In Terms Of Surface Hardness As Per Is 13311 Part 2 1992 Astm C 805 02 Bs 6089 And 1981 And Bs 1881 Part 202 Bs En 13791 Also Establishing Correlation Chart Between Rebound Hammer And Other Confirmatory Test For Having Estimated In Sity Strength Of Concrete If Required In Absence Of The Confirmatory Test Strength Data Will Be Generated On The Basis Of Empirical Formula Obtained From The Callibration Chart , Structuhral Audit Of Bldgs 1C - Ultrasonic Pulse Velocity Test Nos Of Tests 2 For Ascertaining The Quality Of Concrete Uniformity Of Concrete In Terms Of Soundness And Density Of Concrete As Per Is 13311 Part 1 1992 Astm C597 83 Bs 6098 1981 And Bs 1881 Part 203 And Bs En 13791 Also Establishing Correlation Chart Between Ultrasonic Pulse Velocity And Other Confirmatory Test Having Estimated Insitu Strength Of Concrete If Required. , Structuhral Audit Of Bldgs 1D - Core Extraction And Testing Extracting The Concrete Core Samples Following The Codal Provisions And Evaluating The Properties Fck Value Grade Of Concrete In The Laboratory From The Core Samples Selected Is 456 2000 Is 516 And 1959 Is 1199 And 2002
Contract Date: Ref. Documents Contract Value : 2.68 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Andaman And Nicobar Islands View Result →
40.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
41.
Power #9921536 AOC
Tender For Material Supply, Spares & Special Tools - RGC - Construction of 33/110kV Step Up GIS at Pushpakandam-- 1 Design, Engineering, Manufacture, Testing at manufacturers works, Delivery at site including all materials, accessories such as OLTC,RTCC, with Transformer Oil and 10% extra Oil, spares,Gaskets, OTI,WTI,MOLG indicators with transducers and Tools as per specification , loading and unloading, transportation, handling, proper storage at siteThree Phase Two Winding Transformer33/110kV, 60MVA Capacity with optical sensors and Remote Data Transfer facility with optical communication media, and all other accessories complete, with SAS Integration Scope , all required valves and flanges for NIFPS shall be provided for transformer at the time of transformer design itself,inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 2 Design, Manufacture, Testing at Manufacturers works, Transportation and Delivery of 110 kV, 3 Phase Encapsulated Double Busbar Indoor Gas Insulated Switchgearequipmentand other accessories at Substation siteand as per respective Technical Specifications, Single Line Diagram, General Arrangement Drawings, IS/IEC standards, approval of KSEBLand relevant special conditions applicable. The quote for each bay shall include necessary interconnecting GI bus ducts within the building. The supply include all accessories of GIS bay, earthing materials for forming the earth grid inside the GIS hallas per standards of GIS earthing (Cu/Al), including RF Earthing, Cable tray, control cable from GIS to LCC, LCC panel, ladder etc. complete. 3 110 kV GIS Feeder Bay with PT(40kA/ 1250A min) 4 110kV GIS Double Bus bar arragement with PT(40kA/ 2500A min) 5 110kV GIS Bus Coupler Bay(40kA/2500A min) 6 110kV GIS Transformer Bay (40kA/1250A min) 7 Polymer housedSurge Arrester suitable for 110kV, 10kA, Class 3 withclamps, terminal connectors suitable for connection of any type of conductor or Al/cu pipe bus as per requirement, leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete 8 110kV composite solid core station post insulator , clamps, connectors etc suitablefor Al/ Cu Pipe Bus /Conductors. 9 Neutral CT (NCT) 36kV 3150Afor 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 1200-600/1-1 Amps(33 kV side) 10 Neutral CT (NCT) 36kV 3150A for 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 400-200/1-1 Amps(110 kV side) 11 UG power cable- 110kV, Single core, 630sqmm, Aluminium conductor,XLPE insulated,Aluminium Corrugated sheathedandHDPE Outer jacket under ground cable having rated short circuit capacity for both conductor and armourwith necessary Non - Magnetic , Metalic Trefoil/flat formation clamps atminimum 3 metre interval, steel/nylon cable ties wherever necessary 12 Outdoor termination kit suitable for 110kV, 630 Sqmm Single core Copper/ Aluminium UG cable for yard structure mountinginclusive of all accessories like earthing cable, suitable Non - Magnetic, Metalic clamp for fixing cable to support structure etc at 1m interval complete. 13 Indoor Plug in Type GIS termination kit for 110kV 630 Sqmm XLPE Single coreCopper/ Aluminium UG cable,inclusive of all accessories like earthing cable, suitable Non - Magnetic , Metalic clamp for fixing cable to support structure etc at 1m interval complete. 14 Supply of 4IPS Schedule 40 Al. Tube including requiredJointing Sleeves, Expansion joints, etc. withnecessary fixing clamp and all accessories complete for 110kV,33kV equipment to equipment connection 15 Three Phase Link Box 6.6kV withoutSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 16 Three Phase Link Box 6.6kV withSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 17 33kV Indoor composite VCBPanels having bus capacity 31.5 kA for 3sec, 3150A at STC continuous rating, 4 nos feeder bays having capacity not less than 1250A ,2 nos transformer feeder bays (for 33/110kV transformer) having capacity not less than 2000A ,1 nos transformer feeder bay ( for 33/11 kV5MVA Transformer ) having capacity not less than 1250A and1 nos bus coupler with bussection panel not less than 3150A, two bus PT panel at both side of the bus .Every feeder/incomer/ bus coupler shall have CT, E/S, synchro check, SEM Energy Meter, Ammeter, Voltmeter, Control and Protectionincluding earthing as per standards(Cu), cable tray, control cables etc completeand as per SLDand specifications. 33/110 kV 60 MVA Transformer feeder shall have provision for termination of cable size 3 runs per phase of 630 sqmm Aluminium cable. Each incomer panel (transformer) shall be provided with additional special protection class CT cores for differential protection scheme M1 and M2 at 110kV transformer C&R panel. All the feeders shall be remote controlled from SCMS and from the local console of the numerical relays with Bay Control Unit and protection unit including supply of the same. The supply includes one number VCBfor each ratings as spare (2000A, 1250A) and two numbers of service trolley for VCB , E/S, PT and spares (as per attached list clause 6.6 & 6.7 of volume 2, Chapter 27). 18 Polymer housedSurge Arrester suitable for 33kV, 10kA, Class-3 with clamps, terminal connectors etc. suitable for connection ofany type of conductor or Al /Cu pipe bus as per requirement, including leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete (33kV Feeder/ Transformer) 19 33kV 800A Triple Pole Line Isolator with Structure, clamps, terminal connectors etc. suitable for connection of any type of conductor or Al/Cu pipe bus as per requirement 20 33kV Pin insulator with pin 21 33kV composite solid core station post insulator with high level structure with clamp & connectors suitable for Al pipe/conductor. 22 UG power cable- 33kV 1Cx630sqmm Aluminium 33kV, XLPE Aluminium armoured having rated short circuit current capacity for both conductor and armour and HDPE outer jacket for 33/110kV 60MVA transformer incomer with necessary Non-magnetic, metallic, Trefoil/flat formation clamps at minimum 3 metre interval and steel/nylon cable tie wherever necessary 23 Outdoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core Aluminium UG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 24 Indoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core AluminiumUG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 25 Design, Engineering, manufacturing, testing at Manufactures worksite, supply, delivery,loading and unloading, transportation, handling, proper storage at site,supervisionof erection, testing and commissioning of 33/11kV, 5MVA three phase two windingtransformer as per technical speciationsincluding all materials, accessories such as Off Load Tap Changer, Transformer Oil and 10% extra Oil, spare Gaskets, OTI,WTI,MOLG indicators with transducers as per specification and Remote Data Transfer facility with optical communication media, with SAS Integration Scope , inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 26 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 200/1-1 Amps (33kV side) 27 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 300/1-1 Amps (11kV side) 28 Alumimium UG Cable- 33kV, 3Cx300 sq.mm XLPE insulated, Galvanised steel strips armoured power cable for feeders / Aux Tfr with necessarymetallic, non magnetic clamps atminimum 3 metre interval, steel/nylon cable tie wherever necessary 29 Outdoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPE Galvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 30 Indoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPEGalvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 31 Distribution Transformer 11kV/433V, 250 kVA, Star rated (BEE Latest notification as on date of tender)with 11kV & 433V outdoor cable entry box, suitableDistribution Box with LT cable (Trfr to LT box) with 500Amps Fuse and MCCB including all accessories like Busbar, Metering Cabinets etcand its fixing -mounting arrangement on plinth 32 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches and one Vacuum/SF6 breaker suitable for 11KV/433V Auxillary Transformer/ Outgoing feederas per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 33 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches as per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 34 Supply of 11kV indoor VCB 5 panel set with combinations of Incomer feeder panel with PT (1 number), Outgoing feeder panel (3 number) and transfomer panel (1 number) with bay control and protection unit (BCPU) for integration with upstream Substation Automation System (SAS) through HSR/PRP topology (IEC 61850 edt 2 compliant) with protection philosophy specified in technical specification along with supply of accessories necessary for operational spares and special tools (as per attached list clause 37.6 & 38 of volume 2, Chapter 30). Bus Bar ratings are 2000A. Circuit breaker shall be E2 M2 C2 class as per IEC 62271-200. Feeder, transformer and incomer panel shall have capacitive voltage indicators (CVI) and only incomer panel BPCU will have PT inputs. Feeder,transfomrer and incomer panels shall house one each multi-function meter (MFM) and DLMS compatible energy meters. Each Incoming and outgoing feeders shall be equipped with split core type CBCT for Sensitive Earth Fault Protection 35 Supply of Polymeric type LA suitable for 11kV 36 3Cx300sqmm 11kV Aluminium XLPE insulated under ground armoured cable, with necessaryclamps for fixing with support structure at 3 m interval 37 3Cx300sqmm11kV Aluminium XLPE Under ground cable Termination Kit Outdoor Heat Shrinkable 38 3Cx300mm2 11kV Aluminium XLPE Under ground cable Termination Kit Indoor Heat Shrinkable 39 Supply of Hot dip Galvanised LatticeStructurefor 33kV,11kV& 110 kV Switch Yard, Columns/Beams/Pre fabricated Cable Supports in Trenches/lightning mast structure/ lighting mast structure/ equipment structures unless otherwise not specified else where in the BOQ etcinclusive of N&Betc(as per respective Technical Specifications, standards and relevant special conditions). 40 EOT Crane of suitable capacity (minimum 5T safe working load) with single hook and double girder arrangement for GIS Hall. Contractor shall submit the capacity calculation of the crane incorporating 25% additional load considering erection and maintenance of largest GIS component / assembly. 41 DG set 125 kVA silent type, Outdoor plinth mounted withAMF panel, Auto Load Change over module and panels, Battery and its charger, Diesel Tank etc with SAS integration facilities including all accessories complete 42 Battery Set - 110 V, 400Ah , Lead Acid plante Battery SetC10 Duty cycle (Rating is tentative and final sizing as per the load calculation shall be under bidder scope) & Installationwith Battery Racks made with acid proof material ,two number of indsutrial type flame proof exhaust fan and all necessary arrangements including tool kit like hydro meter, chemical gloves, multimeter etc. 43 48V, 200 AH VRLA Battery Set with all associated accessories for reliable communication & data acquistion project complete as per specifications 44 SCADA compatible 110V Dual mode (FC+ BC) Battery Charger, with independent Float (FC)and Boost charging (BC) (2 number rectifier unit) min-FC-80A, BC-80A, suitable for 110V Battery bank as per design and shall charge Battery set as per technical requirement during float /boost mode without interruption to load. The charger shall have two independent incomer supply.(Battery charger shall meet the full DC load during boost condition and the Bidder shall propose the final sizing of the battery charger during detailed engineering for approval)(Both set shall be of different make ) 45 Battery Charger - 48 V Dual mode (FC+BC) (Float - 30A/Boost - 60A) - SCADA compatible, SMPS based,Suitable to VRLA Battery set and shall be able to charge Battery set as per requirement during float /boost mode as well as it shall supply to load as per rated voltage of load components inclusive of necessary power, communication and control cables with all accessories complete -Compact type 46 SCADA compatible DCDB-110 V with minimum 20 + 20 Outgoing feeders duplex type (Floor Mountable) with changeover panel having interlock facility with 20% spare feeder breakers for station control and protection systems as per the station requirement, facility shall be there to charge any battery set with any of the battery chargerwith interlock. Ratings shall be as per the battery sizing calculation. 47 DCDB 48 V with change over facility and min 20 Nos. of Distribution Outlets( 2 Nos.- 10A and 18 Nos. 6A)-DUPLEX Type-SCADA/SAS Compatible-Wall mountable 48 SCADA compatible LT 3 phase 50Hz Panel Boardwith Insulated Aluminium Bus Bar, 2 nos incomers (Auxillary Transformer / DG Set), automatic interlock/load change over facilty, two sets of outgoing,panel with LED indications, panel meters,ACB /MCCB(incomers), MCCB (feeders), Earth Bus bar etc., for LT Power Distribution to Control room/equipments including all accessories complete as perspecifications having minimum 20% spare feeders.Remote operation shall be possible for incomers and DG set.(Panel sizing and rating to be proposed by the bidder during detailed engineering for approval). 49 SCADA compatible LT MLDB/LDB/Street light control DB with Lighting Transformer, Surge Protection Devices, MCCB, MCB, RCCB, ELCB and all accessories complete as per technical specifications for Control Room and Yard lighting including all sub distribution boards, and SCADA compatible ACDB/Sub ACDB for Air Conditioners & AHU with soft starting feature etc. including MCCB, MCB, RCCB, ELCB. (The DB sizing and rating shall be proposed by the bidder, with 20% spare capacity, during detailed engineering for KSEBL approval) 50 SCADA compatible LT Emegency Lighting Distribution Board (ELDB) with 63A Incomer and minimum 12Nos 10A Outgoing Feeders and DC Emegency Lighting Distribution Board (DC ELDB) and related accessories including MCCB/MCB,RCCB/ ELCB as perstandard specifications for Emergency lighting in the substation / Switchyard, charges including all sub distribution boards 51 LT A.C Three Phase Self mounted Indoor Power Kiosk IP 42 with 1 incomer MCCB 63A including indicating lamps,single phase and three phaseindustrial type16A sockets etc. at GIS hall 52 LT A.C Three Phase Self mounted Outdoor Power Kiosk (IP 56) with 1 incomer MCCB 250A, 2 Outgoing MCCB 160A & 100A including indicating lamps,3 phase and singlephase industrial type 16A sockets etc. complete for Transformer oil filteration unit, welding purpose etc. 53 Supply of Protection Panels/Equipments, Substation Automation System and materials as per technical specifications, IS/IEC Standards applicable 54 Control and Protection panel for Transformer with Differential Protection,REF (Transformer management relay) for HV and LV [M1 and M2 relay shall be of different make / platform and each shall have-87, 67/67N, 64R-Low Impedance, Transformer Mechanical Protection- Bucholz, OLTC Bucholz, OLTCPanel Control & signal interfacing with RTCC panel, OTI, WTI, PRD1 &2 through high impedance tripping relays, MOLG Alarms etc.,] 33/110kV 60MVA, with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA system. Energy meters as per technical specifications and suitable for GIS switchgear modules 55 Busbar Protection panel for8 bays (110kV Bus) as per specifications -with zone segregated tripping, LBB, end zone protection, local HMI for displaying differential current, SLD, Isolator Position etc., with output tripping relays (drawout type) and provision for interface to SCADA/SAS system 56 Control and Protection panels (main 1 and 2- 87L,21,67/67N,50N,59,PSB, 79A/R,49,81 O/U) for 110kV Feeders with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA systemas per tech specifications and suitable for GIS switchgear modules (M1 and M2 relay shall be of different make / platform and the combination shall exactly suit with the remote end M1 and M2 relays). Over and above the normal Tri-Vector Meter, the contractor should supply SEM Meters as per SRLDC/PGCIL Standards, additionally. 57 Control and Protection panel for 110kV Bus Coupler with BCU and additional Common BCU for Auxiliary control System and Monitoring including the panel as per standard and requirement of 110kV GIS 58 Design, Manufacture and Supply of Complete SAS system for 110kV GIS , as per detailed technical specification , SAS system Architecture andSLD , Reduntant Servers, Reduntant Gateway, Reduntant Routers with Hardware Firewalls,2 Nos Operator Work Station with HMI -Desktop (one operating work station with extended HMI at Nedumkandam (10Km away)) , 2 Nos. Engineering Work Station(Lap top and Desk top) , one metering PC with DCU for SAMAST metering and Remote Station Controls, necessary Panels and Furnitures etc completewith all necessary accessories, cables,converters, GPS based Time Syncronising Unit IEC compatible to cater data to and from all bays and transformer, SCADA compatible panels,interfacing /intergating line differential relay in CR panel, SAS gateway server panel etc to FODP/Communication equipment in communication room as per specification, including supply of all necessary converters for interfacing with the communication equipment , unarmoured OF cable , 40mm PLBHDPE pipe duct , all interconnecting cables , Patch chords devices etc. complete. The scope include integrating 33kV and 11 kV systems.SAS Architecture should be suitable for plug and play integration of future bays. [Including mandatory Spares as specified in volume 2 - Technical Specfications, Chapter 11, Annexure C] 59 Design, Manufacture and Supply of materials / item for Power Cable, Control Cables and instrumentation cable, Supply of various sizes of 1.1 kV FRLS-0H PVC armoured copper cable for control , Aluminum/ Copper LT power cable as per approved cable schedule (to be prepared by contractor and got approved), and provision of all types of cables from Power and Auxilliary Transformer and other equipments/switchgears, for the substation (Aluminium cables of size 185 mm2 and above shall be XLPE type) includingties , tags etc. supply of suitable size PVC pipe and accessoriesfor drawing exposed cables as per the technical specifications, IS/IEC Standards applicable. 60 12x4mm2 Control CableCopper 61 4x6mm2 Control CableCopper 62 4x4mm2 Control Cable Copper 63 2x4mm2 Control Cable Copper 64 19x2.5mm2 Control CableCopper 65 12x2.5mm2 Control Cable Copper 66 7x2.5mm2 Control Cable Copper 67 4x2.5mm2 Control Cable Copper 68 3x2.5mm2 Control Cable Copper 69 2x2.5mm2 Control Cable Copper 70 2x1.5mm2 Control Cable Copper 71 4x0.5mm2 instrumentation Cable Copper 72 4x10mm2 PVC InsulatedLT copper cables 73 2x10mm2 PVC Insulated LT copper cables 74 2x1.5 sq.mm or higher size PVC Insulated shielded copper cables for Transformer OTI & WTI wiring 75 20/25 mm dia FRLS PVC Rigid/Flexible Conduit including all clamps, clips etc. for Fire Alarm Panel and sensor wiring purpose 76 3 1/2C x300 Sqmm 1.1kV LTXLPE insulated armoured Aluminium cable 77 3 1/2C x 240 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 78 3 1/2C x 120 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 79 3 1/2C x 90 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 80 3 1/2C x 70 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 81 3 1/2C x 50 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 82 3 1/2C x 35 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 83 3 1/2C x 25 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 84 4C x 16 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 85 1x 95 sqmm DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 86 1x 70 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 87 1x35 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 88 Supplying aluminium cable tags with punching number and alphabets up to 7 digits or higher as per requirement for 220/33/11kV power cables including cost of all materials as per the technical and standard specifications 89 Hot dip galvanized ladder type cable tray with joint plate and N&B size300x100x2 with all accessories complete 90 Hot dip galvanized ladder type cable tray with joint plate and N&B size 450x100x2and with all accessories complete 91 Hot dip galvanized ladder type cable tray with joint plate and N&B size600x100x2 and with all accessories complete 92 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Conductor/ Earthing Materials and associated materials for Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable 93 Aluminium Bus bar 120*10mm 94 ACSR Wolf Conductor 95 110 kV 90kN Silicon Composite Longrod Insulator 96 110 kV 70kN Silicon Composite Longrod Insulator 97 110 kV Single Tension H/W and Accessories suitable for Single Wolf 98 110 kV Single Suspension H/W and Accessories suitable for Single Wolf 99 wedge – connector suitale for wolf/Kundah 100 wedge with paddlesuitale for wolf/Kundah 101 Earth Wire 7/3.15 mm Galvanised Steel wire with required hardwares accessories and earthbond 102 Tension Clamp and Tail Clamp for 7/3.15 mm Earth Wire 103 32/40mm MS rod for earthing 104 GI strip all sizes as per requirement for earthing 105 Clamp and saddle for GI strip/wire 106 Test link for lightning protection 107 1.5m GI lightning spike with fixing clamps 108 Design and supply ofVentilation system for GIS hall(positive pressure type)with prefilters and fine filters of washable type for 100% capacity of GIS hall, with air displacement of 5 times the volume of GIS hall per hour (one operating + one standby , consisting of two units each having capacity 5 times air changes per hourof GIS hall workingcyclically for 50% of time)with soft starting feature,comprising of GI ducts( with provision for nitrile rubber insulation if taken externally), fire dampers, exhaust dampers, grills, noise reduction system etc. complete.The system shall be monitored via SCADA including necessaryelectrical panels. 109 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Fire and Safety Equipments and materials for 33/110kV Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable- Portable and wheel/ trolley mounted fire extinguishers for Control room 110kV GIS Hall, 110kV Switchyard Relay panel room of GIS Hall,Transformers and other Strategic locations including its installation at site 110 Dry chemical powder of 9kg capacity 111 Dry chemical powder of 25kg capacity 112 Dry chemical powder of 50kg capacity 113 CO2 gas type of capacity 6.5kg 114 CO2 gas type of capacity 22.5kg 115 Mechanical foam type capacity 9LT 116 Mechanical foam type capacity 50LT - 117 Fire Stand with 4 buckets(Including Concreting as per drawings) 118 SCADA compatible - Main Fire Alarm Control Panel (Zone of protection as per approved scheme) complete with Charger, Rectifier, Visual Display, battery back up complete as per the station requirement 119 Photo Electric type Smoke detector with base compatable for Fire Alarm Panel 120 Photo Electric type Heat detector with base compatable for Fire Alarm Panel 121 Supply of Beam Detector and Reflector for GIS with base compatable for Fire Alarm Panel 122 Audio Alarm with Hooters cum Speakers compatable for Fire Alarm Panel 123 Manual Call point of Break Glass Type with hammer and chain 124 Insulating Mat (Size 2000x1000x2mm) class A including its fixing at site as per Technical Specification and IS 125 Safety Chart for First Aid, Electric Shock & Fire and Fire Fighting Equipments including its fixing accessories complete 126 Lighting and General / Miscellaneous Items 127 Optical Fibre Cable (12F Single Mode and 12F Multimode) , SM and MM Patchcords, all necessary connectors complete, as per site requirement for extended HMI, bus bar protection other than SASas per site requirement and technical specification 128 Ground Enhancement Material (GEM) ( Per Bag -11.33 Kgs ) - Conforms IEC 62561-7 Standard. The GEM shall have Resistivity of less than 20 Ohm-cm and Environmental friendly 129 Visual Monitoring System (VMS) with surveilliancecamera as per technical specification and layout drawing (Including local PC monitoring set up having sufficient storage capacity, remote end PC monitoring if necessary set up shall be in the scope of supply) including necessary power and communicationcables, interconnecting hardwares, PVC pipes and all other accessoriesetc complete as per the technical specifications (minimum requirement : Fixed Camera : min 8 Nos, Pan Tilt Zoom Camera : min 2 Nos, Fixed Variable Focus: min 4 Nosand storage >8TB) 130 Design of Air Conditioning system and Supply of5 Star rated (as per latest BEE notification)2TR or higher capacity split type inverter Air Conditioners, with stabilizer, Power Isolator etc.for Control & Relay panel room, Communication room, SCADA room, Bay Control Room (each room has got minimum one unit of redundancy, cyclically operated with Room temperature indicator) as per detailed engineering and approval. Temperature indicators shall be integrated to SCADA 131 SPARES for GIS - 220/110kV 132 Tripping & closing coil(Each Breaker type Module) 133 Motor for disconnector of each type of equipment 134 Motor for CB spring charging (each Breaker Type) 135 SF6 Pressure Guage for Circuit Breaker 136 SF6 Pressure Guage for other compartments 137 SF6 Pressure Relief Device 138 Auxillary contact assembly for Circuit Breaker 139 Auxillary contact assembly for Disconnector/Isolator-each type 140 SF6 gas 141 Moisture absorbant catridge 142 NRV gas filling valve for equipment 143 Indication lamps and lamps for semaphores & annunciators- one for each type & colour 144 Annunciator full set each type with one set of relay card 145 Special tools for Installation and Maintenance -220/110kV 146 Gas Leakage detector - DILO make 147 Special spanners for General maintenance for supplied GIS 148 SF6 gas bottle locking , measuring and filling assembly with whole hose 149 Measuring Instruments 150 Clamp on meter- capable to measure mA range .• High sensitivity, miniature AC/DC clamp meter.Range: 200mA/2/20A AC, 2/20A DCMin. resolution for AC: 0.1mAMin. Resolution for DC: 1mAJaw size: 7.5mm all required accessories from following make and model Fluke,MEGGER,KYORITSU 151 Phase Sequence meter with Standard accessories -Fluke,MEGGER,KYORITSU 152 Digital Multimeter 279FC TRMS Thermal or advancedFluke,MEGGER Model 153 Analog Multimeter, with Standard accessories - Fluke,MEGGER,KYORITSU 154 SF6 gas Analyser including DEW point,purtity & Hygrometer etc.
Contract Date: Apr 01, 2026 Contract Value : 369.42 Crore
Boards / Undertakings / PSU No of Bidders 8
42.
Drinking Water Supply and Sanitation #9912604 AOC
Tender for Repair And Maintenance Works To Velusamypuram Panchayat Union Elementary School- Dismantling and clearing away existing for Plain Cement Concrete including cost of conveyance and labour charges at site, other incidental charges etc., complete PWD 2024-25 P.NO:27 2 Dismantling and clearing away existing for Doors and windows including removal of frames, hinges and fastenings including cost and conveyance at site of labour charges etc. complete PWD 2024-25 P.NO:28 3 Dismantling and clearing away existing Damaged Brick work in Cement Mortar including cost and conveyance labour charges and other incidental charges etc., complete as per std. Specification. PWD 2024-25 P.NO:27 4 Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum 5 Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 6 Dadooing walls withGlazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. 7 Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement 8 Supply and fixing in position of white glazed of 20” size Indiantype water closet with ‘p’ or ‘S’ trap and a pair porcelain foot rest toslaps set in bricks jelly cc 1:4:8100mm thick using 20mm thick jelly and finishing to sludge out any leakage and defaultincludingcost and conveyance of all materials labour charges for fixing inposition and other incidental charges etc., complete as directed by dept. officers. 9 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colour for PVC concealed light / fan point (6Points Per Coil) (For Rooms like Bath, Toilet & Pump room etc..) (SD-26). 10 Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3 mm thick Hylem sheet cover for 5 A3 pin non inter locking CS Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. [SD38] 11 Supply and fixing of4-18WLED tube with fitting inclusive of all charges 12 Supply and delivery of the following PVC pipes and specials including cost of materials to site, loading & unloading and conveyance charges and other incidential charges etc., complete. 13 160mm dia PVC Pipe 6Ksc 14 160mm dia PVC Elbow 15 160mm dia PVC Bend 16 160mm dia PVC Tee 17 32mm dia PVC Pipe 10 KSC 18 32mm dia PVC Coupling 19 25mm dia PVC Pipe 10KSc 20 25mm dia PVC Elbow 21 25mm dia PVC Coupling 22 20mm dia Brass Tap 23 Supply, delivery and fixing of 2000Lit Capacity of HDPE Tank as per IS 12701/1996 including loading, unloading, transporatation and labour charges for fixing of the GI Pipes and specials for pipe connection works including cutting and threading charges and inclusive of materials cost, labour conveyance hoisting and fixing charges etc., complete as directed by Departmental Officers 24 FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers 25 Plain Cement Concrete 1:2:4 (one cement, two fine aggregates & four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per std specification 26 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter. (PWD 2023-24 Pg No:43 M-0391 ) 27 Supply and fixing of M.S Grills with Ventilator arrangements with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 28 White washing two coats using best shell lime including, cost and conveyance, labour charges and other incidentalcharges etc., complete as directed by Deptl.officers. 29 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of Paris, putty, wherever required etc., complete complying with standard specification. 30 supply and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD 110 31 supply and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD 110
Contract Date: Mar 31, 2026 Contract Value : 7.40 Lakh
Local Bodies No of Bidders 2
44.
Drinking Water Supply and Sanitation #9861196 AOC
Tender for N.S. Item , Providing And Fixing Battery Powered Ultra Sonic Meteorology Sensing System (Flow Meter) 150 Mm I/D With Ip68 Enclosure Against All Weather Impact, Durable, Good Tensile Strength, Corrosion Resistant, Powder-Coated Metal Casing, Inbuilt Dual Sim (4G/5G), Lcd Display With Flow Direction, Forward And Reverse Flow Rate, Cumulative Forward Flow, Device Name Etc, Accuracy Shall Be As Per Iso 4064, Class 2, Private Access On Desktop And Mobile, Secure Cloud (Cloud Based Software Comprising Of Middle Ware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting. Cloud Services Of Ministry Of Electronics And Information Technology (Meity), Government Of India Empanelled Cloud Service Providers Shall Be Taken. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages.) (Inline Flange Type) , Providing And Fixing Battery Powered Ultra Sonic Meteorology Sensing System (Flow Meter) 200 Mm I/D With Ip68 Enclosure Against All Weather Impact, Durable, Good Tensile Strength, Corrosion Resistant, Powder-Coated Metal Casing, Inbuilt Dual Sim (4G/5G), Lcd Display With Flow Direction, Forward And Reverse Flow Rate, Cumulative Forward Flow, Device Name Etc, Accuracy Shall Be As Per Iso 4064, Class 2, Private Access On Desktop And Mobile, Secure Cloud (
Contract Date: Apr 24, 2026 Contract Value : 1.42 Crore
Government Departments No of Bidders 3
45.
Drinking Water Supply and Sanitation #9861195 AOC
Tender for N.S. Item , Providing And Fixing Battery Powered Ultra Sonic Meteorology Sensing System (Flow Meter) 150 Mm I/D With Ip68 Enclosure Against All Weather Impact, Durable, Good Tensile Strength, Corrosion Resistant, Powder-Coated Metal Casing, Inbuilt Dual Sim (4G/5G), Lcd Display With Flow Direction, Forward And Reverse Flow Rate, Cumulative Forward Flow, Device Name Etc, Accuracy Shall Be As Per Iso 4064, Class 2, Private Access On Desktop And Mobile, Secure Cloud (Cloud Based Software Comprising Of Middle Ware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting. Cloud Services Of Ministry Of Electronics And Information Technology (Meity), Government Of India Empanelled Cloud Service Providers Shall Be Taken. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages.) (Inline Flange Type) , Supply And Erection Of 12 W Led Based Solar Light Street Light And Pole Of 5 Mtr With Rms Above Ground Level Complete In All Respect. , Less Credit For Ci Special , Credit Of Old Clear Water Pumping Machinery Of 1200 Lpm X 40 Mtr. Head ( As At Site)Including Dismantling Charges Without Electrical Panel And Valves, Pipes, Etc. , Credit Of Old Clear Water Pumping Machinery Of 800 Lpm X 30 Mtr. Head ( As At Site)Including Dismantling Charges Without Electr
Contract Date: Apr 08, 2026 Contract Value : 1.02 Crore
Government Departments No of Bidders 5
46.
Educational and Research Institute #9800564 AOC
Tender For Construction Of Academic Block Building In University College Of Engineering, Bit Campus, Trichy District.; 1 Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- 2.40m-3.30M Footing Depth.Data worked out for 48 m3 per day/8 hrs. 2 Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.A). Upto 2.40m Depth.Data worked out for 64 m3 per day/8 hrs 3 Refilling with excavated earth other than sand with an initial head load of 100 mts and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. 4 Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 5 Supplying and Filling in foundation and basement and trenches with M-Sand in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. 6 Supplying and filling of 40mm HBGS metal in dispersion trench around the stoneware pipe or in the leach pit or rain water harvesting pit or soak pit to the required thickness complete complying with standard specification and as directed by the departmental officers. (The rate including cost of metal filling etc. complete complying with standard specification.. 7 Supplying and filling of 20mm HBGS metal in dispersion trench around the stoneware pipe or in the leach pit or rain water harvesting pit or soak pit to the required thickness complete complying with standard specification and as directed by the departmental officers. (The rate including cost of metal filling etc. complete complying with standard specification. 8 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means 9 Providing Anti – termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work).Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation.Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth.Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout.Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment. etc., complete complying with standard specification and as directed by the departmental officer. 10 Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 11 For Foundation & Basement 12 For Super structure in Ground Floor 13 For Super structure in First Floor 14 For Super structure in Second Floor 15 Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 16 For Foundation & Basement 17 For Super structure in Ground Floor 18 For Super structure in First Floor 19 Providing and laying in position, Standardised Concrete Mix M-35 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability withoutimpairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 20 For Super structure in Ground Floor 21 Post Tensioning Work: Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents,making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering,concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately. 22 Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed st one sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. 23 50mm thick 24 75mm thick 25 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 26 For Foundation & Basement 27 For Super structure in Ground Floor 28 For Super structure in First Floor 29 For Super structure in Second Floor 30 Finishing the top of roof with Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means 31 For Foundation & Basement 32 For Super structure in Ground Floor 33 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 34 Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 35 Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 36 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid) 37 Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 38 Brick work in 1:6 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 39 For Foundation & Basement 40 For Super structure in Ground Floor 41 For Super structure in First Floor 42 For Super structure in Second Floor 43 Brick work in 1:5 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 44 For Foundation & Basement 45 Brick work in 1:3 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 46 For Foundation & Basement 47 Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Machine Mixing 48 Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 49 For Super structure in Ground Floor 50 For Super structure in First Floor 51 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 52 Stucco plastering 12mm thick using blue granite chips of size 10mm and below over a base plastering with cement mortar 1:5, 12mm thick, etc., complete complying with standard specifications 53 Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification andas directed by the departmental officers. 54 Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directedby the departmental officers. 55 Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. 56 Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. 57 Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer beforeuse on works) 58 Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessory PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers 59 160mm dia PVC Pipe - For One Floor 60 160mm dia PVC Pipe for Two Floors 61 160mm dia PVC Pipe for Three Floors 62 110mm dia PVC Pipe for One Floor 63 Paving the floor with best quality Double charged Vitrified tiles 600 x 600 x 8mm size of approved colour and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 64 Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 65 Paving the floor with Tactile paver type of new tack BT yellow colour ceramic tiles of approved quality and colour of size 305 x 305 x 15mm in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works). 66 Paving the floor with best approved quality fine polished Granite Synthetic Slabs of 1200 x 600 of 16/ 18 mm thick size and synthetic grey, Paradise of similar Variety with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) 67 Labour charges for finishing the top of working tables and staircase step portion with nosing arrangements in Granite slab tiles including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers. 68 Flooring with ceramic tiles of Colour and Design Ceramic Tiles of size 305x305x6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m.etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 69 Dadooing walls with following best approved quality, printed design colour glazed tiles of size 150mm x 150mm x 6mm glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 70 Supplying and fixing of PVC corner size beeding of best approved quality of 25 x 75 mm size and thickness of required height of walls using cement mortar 1:2 (One cement and two sand) and finishing the surface smooth with ceramic tiles etc., complete complying with standard specification and as directed by the departmetal officers. 71 Providing granolithic floor finish of the 20mm thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 72 Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the departmental officers. 73 Supplying and fixing in postion of 35mm thick solid core flush door shutters with following specification. with TW ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, as directed by the departmental officers etc., complete. 74 Single Leaves 75 Double Leaves 76 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 77 Manufacturing, supplying and fixing of 1/3 panelled and 2/3 grilled steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sandwitching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m and 3 Nos Steel Parliament Hinges of Size 125mm x 150mm incase single leaves shutter to be provided, 6 Nos Steel Parliament Hinges of Size 125mm x 150mm for double leaves shutter to be provided, 6nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided. one aldrop is provided at on appropriate place in the door. 2Nos of handle are to be provided. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m. 78 FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers 79 Supplying and fixing of PVC Sliding Door with Roller using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 80 UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. 81 Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers . 82 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint over the priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 83 Painting the new wood work two coats with best approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work). 84 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 85 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 86 Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable nonabsorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed by the departmental officers. 87 Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers 88 Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers. 89 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 90 Brick Jelly Lime Concrete 1:2:5 using 40mm brick jelly in Lime Mortar 1:2 using limestone and sand - 10 Cu.m for sunken portion etc. complete complying with standard specifications and as directed by the departmental officers. 91 Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications 92 Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers 93 Supplying and fixing of RCC hume pipe of flush joint to a size 300mm RCC wall with 25mm thick to a length of 30cm in RCC M 35 with nominal special reinforcement as directed by the departmental officers etc., complete complying with standard specification. 94 Supplying and installation of Ceramic Steel chalk writing board with the following specification. The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners. The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers. 95 Supplying and fixing of good quality and best make of Chalk Piece and Duster Holder of size 300 x 200mm made up of stainless steel in the places shown by the departmental officers including transporting to the work site, fixing in position etc., complete complying with standard specification. 96 Supplying, fabricating, erecting and fixing Hilux (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level.etc., complete complying with standard specification and as directed by the Departmental officers 97 Supplying and fixing Gyp-board designed Cornices of 100x60mm width in the edges of the false ceiling wherever necessary as per the direction of the filed officers. The rate includes the cost of materials, transportation charges and fixing charges and other incidental charges etc., the pattern of the cornice has to be approved by the Executive Engineer before used on work etc., complete complying with standard specification and as directed by the departmental officers. 98 Supplying and fixing ornamental Brass-in-lay Burma Teak Wood Entrance Door with a size of 2.10 m x 2.55m with six leaves as per the drawing and design as approved by the departmental officers.The clear opening of each door shall be of 2.00m. The outer frames are of finished size 175mm x 125mm.The Each door shall have two leaves of 1/3 panelled and 2/3 glazed. The Outer frame of the shutter of finished size of 150mm x 50mm.All the Panels shall be of finished 50mm thick. The main outer frame, shutter frame and panels shall be engraved with computer design ornamental carving works of approved pattern with skilled carpenter as directed by departmental officers. All the glazing works shall be done with design painting works.Necessary grill protection arrangements shall be made for the glass portion. The door frame and shutters shall given two coats of best and approved quality of high Glossy Polyurethane finish.The rate includes cost of best and approved quality of Burma Teak wood,design painted glass, Brass hinges,Tower bolts, Aldrop, locking arrangments,ornamental handles,brass screws and labour charges, transportion charges, all taxes, etc., complete. 99 Drilling 150mm dia vertical bore well to the required depth as directed by the departmental officers including labour charges inserting pipes assembly in the drilled pit including welding the joints wherever necessary and grouting the casing pipe if necessary in hard rock etc. complete and including transportation charges for the rigs and supporting vehicles from one place to another etc. complete as directed by the Executive Engineer. 100 Upto 150m BGL 101 Upto 150m to 180m BGL 102 Upto 180m to 210m BGL 103 Supplying 160mm dia Special Blue Slotted Pipes for Bore Wells of pressure 6kg/m2 in the drilled hole of the following dia in 3m length with screwed and socket ends and centering guide for every 15 m length of pipes as per I S I 12818/1992 inclding welding the joints supplying and poeting the annular space with pebbles of size and quality etc complete as directed by the departmental officer 104 Supply of 160 mm dia PVC End cap of best approved quality having pressure of 6 kg/sq.cm. etc. complete as directed by the departmental officers. The pipe should be got approved by the Executive Engineer before use on works. 105 Supplying and delivery of best and approved quality of 40mm dia HDPE pipe of 10kg/m2 size including laying in the basement and tying with copper wire etc., complete complying with standard specification for delivery line from the bore from submersible pump in borewell and as directed by the departmental officer. 106 Supplying and fixing of MS borewell clamp suitable for 40mm dia pipe and 4 Nos. of bolts and nuts of best approved quality etc. complete and complying with standard specification and as directed by the departmental officers . 107 Supplying, fixing and Erecting in position of single phase 5.00 H.P Submersible Pumpset suitable for 150mm dia Borewell with ISI IS 8034 with 3 phase Panel Board - Star Delta with two level guard and Auto start including Transport charges etc., complete complying with standard specification. 108 Supplying and tying of Nylon rope of 18mm dia thread make with best quality for holding submersible pump etc., complete as directed by the Executive Engineer. The Rope should be got approved by the Executive Engineer before use on works. 109 Supply of 2.50 Sq.mm PVC insulated and shethed 3core flat type finolex copper cable for motor pump electrfication confirming tro IS 694/1996 including conveyance to work site etc.. 110 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply Below ground level. 111 50mm dia UPVC pipe 112 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply Above ground level. 113 40mm dia UPVC pipe 114 32mm dia UPVC pipe 115 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/ sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level. 116 25mm dia UPVC pipe 117 20mm dia UPVC pipe 118 Supplying and fixing the following UPVC specials of heavy type and approved quality and good variety excluding the fixing charges but including necessary cutting and threading on UPVC pipes for jointing UPVC Specials and providing two coats of painting with good variety of paint over a coat of priming coat in the case of pipes line above ground level and one coat of tarring in case of the pipelines above ground level and one coat of tarring in case of the pipelines below ground level etc,complete 119 50mm dia UPVC Union 120 40mm dia UPVC Union 121 32mm dia UPVC Union 122 25mm dia UPVC Union 123 50mm dia UPVC Elbow 124 40mm dia UPVC Elbow 125 32mm dia UPVC Elbow 126 25mm dia UPVC Elbow 127 40mm dia UPVC Hex Nipple 128 32mm dia UPVC Hex Nipple 129 25mm dia UPVC Hex Nipple 130 25x20mm UPVC Reducer Elbow 131 20x15mm UPVC Reducer Elbow 132 40mm dia UPVC Tee 133 32mm dia UPVC Tee 134 25mm dia UPVC Tee 135 25x20mm UPVC Reducer Tee 136 20x15mm UPVC Reducer Tee 137 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the departmental officer before use on work. 138 32 mm dia Gate Valve 139 25 mm dia Gate Valve 140 Supplying and fixing in position 15mm dia brass CP screw down tap tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) 141 Supplying and Fixing of PVC ready made water tank of approved quality with standard specification and best brand including testing for leakages after making installations and connections. The cost inclusive of lid and lock with bolt and nuts for PVC tank, transportation, loading, unloading, lifting, installation and necessary connections etc., complete complying with standard specifications and as directed by the departmental officers.(The PVC Water Tank should be got approved by the Executive Engineer before use on works). 142 Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with P trap or S trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet and all accessories should be got approved by the departmental officers before use on work) 143 Supplying and fixing in position White Glazed European water closet of best quality and approved make with 100mm P or S trap with double flapped rigid PVC.seat cover with chromium plate brass hinges, including supplying and fixing PVC. Low level flushing tank 10 litre capacity of approved quality on wall with teak wood plugs, brass screws and 2 numbers 15mm dia gun metal wheel valve, 15mm dia nylon connection and giving necessary water supply connection as directed by the departmental officers. The rate includes cost of 100mm dia PVC.Pipe 60cm long including cost of 3 Kg.of white cement 6Kg.of cement, spunyarn, shellac, thread ball, teak wood plugs, brass screws 75mmx10mm etc., complete complying with standard specification and as directed by the departmental officers. (The European Water Closet and flushing tank should be got approved by the Departmental Officers before use on work.) 144 Flooring with Snow White Marble Slab (Adanga) 18mm to 20mm thick and above free from all defects in all floors over a base layer of CM 1:3, 20mm thick including Mortar Plasticizer. The marble slab shall be laid over the cement mortar by applying cement slurry in between base mortar and marble slab and pointed with white cement neatly including polishing with polishing stone and oxalic acid etc. so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. complete complying with standard specification and as directed by the departmental officers. (The marble slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work). 145 Supplying and fixing Stainless steel health faucet of best quality with control valve etc., complete complying with standard specification and as directed by the departmental officers (The materials should be got approved by the Executive Engineer before use on works). 146 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.) 147 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 148 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror of following size , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc.,complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size :600 x 450 mm / 500 x 400mm / 1000 x 780 mm. 149 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 150 Supplying and fixing position CI Nahani Trap of size 100 x 75mm sizes with pvc gratings with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving conne tion to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) 151 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the departmental officer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 152 75 mm dia PVC soil waste pipe 153 110 mm dia PVC soil waste pipe 154 160 mm dia PVC soil waste pipe 155 Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). 156 110mm dia PVC door Tee 157 110mm dia PVC Door Y 158 75mm dia PVC door Elbow 159 75mm dia PVC plain Bend 160 PVC Cowl 110mm dia 161 PVC Cowl 75 mm dia 162 Supplying and fixing of Incinerator for Ladies Toilet etc., complete complying with standard specification and as directed by the departmental officers. 163 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. 164 Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers. 165 Supplying and fixing of Hylem sheet 3mm thick for expansion joint etc., complete complying with standard specification and as directed by the Departmental officers 166 Construction of INSPECTION CHAMBER of clear size of 600x600mm including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five M sand] using best quality of second class Table Mould Bricks of size 9 x 43/8 x 23/4 with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. 167 Providing granolithic floor finish of the following thickness with Combination Mortor (Cement:Lime:Sand) 1:1:7 including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 168 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End etc., complete complying with standard specification and as directed by the Departmental officers 169 Wiring with 2 x1.5 sq.mm PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sqmm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) etc., complete complying with standard specification and as directed by the Departmental officers 170 Wiring with 2 x1.5 sq.mm PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sqmm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End etc., complete complying with standard specification and as directed by the Departmental officers 171 Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. etc., complete complying with standard specification and as directed by the Departmental officers 172 Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube etc., complete complying with standard specification and as directed by the Departmental officers 173 Supply and fixing of 2 x 22W 4 Feet LED Fitting with 2Nos. of 2Mts. conduit pipe suspension from ceiling with 2Nos. of 18w crystal glass LED tube with PVC unsheathed Copper leads from terminals to the fitting. etc., complete complying with standard specification and as directed by the Departmental officers 174 Supply and fixing of WT bulk head fitting with guard (Higher end) suitable for 7W/9W LED Bulb etc., complete complying with standard specification and as directed by the Departmental officers 175 Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting etc., complete complying with standard specification and as directed by the Departmental officers 176 Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting etc., complete complying with standard specification and as directed by the Departmental officers 177 supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .etc., complete complying with standard specification and as directed by the Departmental officers 178 Supply and fixing of 1200 mm (48) AC ceiling fan complete 2 module 100W fan step regulator with 500 mm down rod on the existing clamp. etc., complete complying with standard specification and as directed by the Departmental officers 179 Supply and fixing of 1200mm (48) ceiling fan complete 2 module 100W fan step regulator with 2mts. down rod on the existing fan clamp. etc., complete complying with standard specification and as directed by the Departmental officers 180 Supply and fixing of 400mm (16) sweep Wall mounting fan with necessary connection etc., complete complying with standard specification and as directed by the Departmental officers 181 Supply and fixing of 300 mm (12 inch) sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.etc., complete complying with standard specification and as directed by the Departmental officers 182 Supply and fixing of louvers shuters arrangements for 300mm (12 inch) sweep (light duty) AC exhasut fan etc., complete complying with standard specification and as directed by the Departmental officers 183 Supply and fixing of 150W LED flood light fitting with Integrated driver (Higher end) complete suitable angle iron frame work on wall with unsheathed Cu Leads with MS clamps and aluminium painting complete etc., complete complying with standard specification and as directed by the Departmental officers 184 Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 185 Supply and Run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion etc., complete complying with standard specification and as directed by the Departmental officers(For 1No.6A plug) 186 Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers) 187 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 188 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion etc., complete complying with standard specification and as directed by the Departmental officers(For 3Nos.6A computer plug set & 16A Plug) 189 Supply and fixing of 25 Amps flush type wall Socket with 25A DP MCB in flush with wall with earth connection (For AC Plug) [Higher end make] etc., complete complying with standard specification and as directed by the Departmental officers 190 Supply and fixing of 6 A to 32 A DP MCB in 2 way sheet steel enclosure in flush with wall and making good of the concealed portion and earth connection. (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 191 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only Higher End etc., complete complying with standard specification and as directed by the Departmental officers (Lighting only) 192 Supply and run of 2 of 4 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. etc., complete complying with standard specification and as directed by the Departmental officers(For 25A AC Plug, 32A DP MCB & 8W SPN) 193 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers(For Computer plugs) 194 Supply and run of 2 of 6 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour etc., complete complying with standard specification and as directed by the Departmental officers(12W SPN DB) 195 Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher end) etc., complete complying with standard specification and as directed by the Departmental officers 196 Supply and run of 4 of 4 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. etc., complete complying with standard specification and as directed by the Departmental officers(For 32A FP MCB) 197 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal /acrylic door cover flush type /surface type fitted with busbars and neutral links with single / Three phase MCB outgoings and seperate 4 way provision for accomodating one no 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators (totally 12 nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq mm with the following in flush with wall with earth connection only.i) 63A 4P MCB - 1 no.ii) 63A 4P 30MA RCCB/ELCB - 1 no.iii) 63A DP MCB Isolator -3 nos.iv) 6A to 32A SP MCB - 12 nos. etc., complete complying with standard specification and as directed by the Departmental officers (Lighting Distribution DB) 198 Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 18 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only. i) 63A 4P MCB - 1 no.ii) 63A 4P 30MA RCCB/ELCB - 1 no.iii) 63A DP MCB Isolator -3 nos.iv) 6A to 32A SP MCB - 18 nos.etc., complete complying with standard specification and as directed by the Departmental officers (c.plugs,16A plugs- Distribution DB) 199 Supply and run of 4 of 10 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. (For 63A FP MCB) etc., complete complying with standard specification and as directed by the Departmental officers(4w 7seg.63A TPDB) 200 Supply and fixing of vertical type 4 way triple pole MCB DB with metal door cover with IP 42 protection in sheet steel enclosure with 1No. 100A 4 pole MCB isolator as incoming 4Nos. 63A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCB DB and MCBs should be with the ISI mark (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 201 Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 15 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 202 Supply and run of 4 of 16 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour.etc., complete complying with standard specification and as directed by the Departmental officers (4w (V) 100A TPDB & 8w (V) 100A TPDB) 203 Sub switch Panel: Supply and Erection of 250A capacity dust and vermin proof cubical panel board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two Horizontal rows with one switch over the other, with a central bus bar chamber and two ends one on each side next to the fuse switch chamber and cable alloy conforming to IE rulesEB INCOMER: 250A FP switch disconnector fuse units interior only with HRC fuse Double Break Switch -1 NoOUTGOING:100A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -4Nos63A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -6 Nos(All the TPN Switch should be Siemens with Front Handle) Suitable The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans. 2 Nos 25x3mm tinned copper flats should be provided all round the panel for earth bus. 204 The fuse Switches should be connected with the phase and natural buses with suitable size of rigid copper flat/rod and each switch should be connected with the 2 Nos earth bus with 2 runs of No.8 SWG rigid Tinned copper rod with suitable lugs. Phase and neutral tinned buses should be tinned properly.The panel should have a separate metering chamber at the top side consisting of 0-600V Voltmeter with Selector Switch, 0-400A Ammeter with Selector Switch and C.T arrangement Pilot lamps, toggle switches, fuse unit(Siemens) indicator lamps should be provided with control switches and fuse unit The panel should be Powder Coat paint of approved colour, approved by the site officer and also the danger board .The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber. The pannel board should be mounted on 75mm x37mm MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 0.75 m from the ground level with necessary earth connection. (DATA-11) 205 Supply and Laying of 31/2 x 185 sq.mm. PVC armoured LTUG cable in120mm/103.50mm dia size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc., complete complying with standard specification and as directed by the Departmental officers(Existing MV panel to Academic block-New 250A Panel)(Existing MV panel to Seminor Hall -New 250A Panel) 206 Supply and clamping of 3½ X 185 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps.etc., complete complying with standard specification and as directed by the Departmental officers 207 Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 208 Supply and providing cable end termination of 3½ x185sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete etc., complete complying with standard specification and as directed by the Departmental officers 209 Supply and fixing of LT cable route indicator with suitable angle not less than 38mm x 38mm 6mm and 0.6mtr long excavation of earth to a depth of 0.6 mtr and concreting the ground level and making good of the ground as directed by the departmental officers. etc., complete complying with standard specification and as directed by the Departmental officers 210 Earthing as per the ISI specification with an earth electrode of 2.1mt class B GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. etc., complete complying with standard specification and as directed by the Departmental officer 211 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 212 Supply and Run of 1 of No.8 SWG copper wire for earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 213 Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. etc., complete complying with standard specification and as directed by the Departmental officers 214 Supply and clamping of 3 1/2 x 70 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.etc., complete complying with standard specification and as directed by the Departmental officers 215 Supply and fixing of brass cable gland for 3 1/2 x 70 sqmm PVC armoured LTUG cable with earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 216 Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete etc., complete complying with standard specification and as directed by the Departmental officers 217 Supply and fixing of 32A TPN MC switch on suitable angle iron frame work with MS cable entry box with earth connection only. etc., complete complying with standard specification and as directed by the Departmental officers 218 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 219 Supply and Laying of 31/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. etc., complete complying with standard specification and as directed by the Departmental officers 220 Supply and clarnping of 31/2 x 25sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. etc., complete complying with standard specification and as directed by the Departmental officers 221 Supply and fixing of brass cable gland for 31/2 x 25sq.mm. LTUG armoured cable with earth connection etc., complete complying with standard specification and as directed by the Departmental officers 222 Supply and fixing of 250 Amps TPN sheet double break switch with HRC fuse and neutral on suitable angle iron frame work with MS cable entry boxes and with earth connection only etc., complete complying with standard specification and as directed by the Departmental officers 223 Supply and Errection of 2Nos. 250A TPN switch disconnector fuse units interior only with HRC fuse Double Break in the existing MV panel board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two Vertical rows with one switch over the other, with a central bus bar chamber and two ends one on each side next to the fuse switch chamber and cable alloy conforming to IE rules.The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans. 2 Nos 50x6 mmand 2 Nos 25x3mm tinned copper flats should be provided all round the panel for earth bus.The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber with necessary earth connection etc., complete complying with standard specification and as directed by the Departmental officers 224 Supply and Fixing of AC/DC 2 Module Gang Bell suitable for 230Volts 50c/s single phase AC supply on suitable angle iron frame work with 1/2 module flush mounting box (GI) and 2 module white cover plate with frame (Plastic) with 6A Bell Push-1 Module with necessary connection. (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 225 Supply and run of 2 of 1.5 sq mm (22/0.3) PVC insulated SC unsheathed Cu Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with painting of suitable colour etc., complete complying with standard specification and as directed by the Departmental officers
Contract Date: Feb 11, 2026 Contract Value : 16.70 Crore
Local Bodies No of Bidders 4
47.
Housing Urban and Rular Development #9795438 AOC
Tender for Earth Work Excavation For Foundation By Mechanical Means For Isolated & Combined Footing Etc In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sides And Raming Of Bottoms Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.- Upto 2.40M Footing Depth. Data Worked Out For 48 M3 Per Day/8 Hrs. , Earth Work Excavation For Foundation By Mechanical Means For Isolated & Combined Footing Etc In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sites And Raming Of Bottoms At The Site, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. A. For Footing Depth 2.40M To 3.3M Data Worked Out For 54 M3 Per Day/8 Hrs.-A. For Footing Depth 2.40M To 3.3M , Earth Work Open Excavation By Mechanical Means For Open Earthwork In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sides And Raming Of Bottoms Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. A). Upto 2.40M Depth. Data Worked Out For 64 M3 Per Day/8 Hrs. , Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundation Including Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Including Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. -Mixing By Manual Means , Supplying And Filling In Foundation, Basement, Etc With Filling Crushed Stone Sand In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supply And Filling In Foundation And Basement With Gravel In Layers Of Not More Than 15Cm.Thick Well Rammed Watered And Compacted With Surface Vibrator, Watered And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Filling In Foundation, Basement, Etc With Conveyed Earth In Layers Of Not More Than 150Mm Thick Layers Well Watered, Rammed With Surface Vibrator And Consolidated Including Conveyance Charges Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Refilling With Excavated Earth Other Than Sand With An Initial Head Load Of 100 Mts. And Depositing The Earth As Shown By The Departmental Officers In Layers Of Not More Than 15Cm Thick Well Rammed With Surface Vibrator, Watered And Consolidated Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Jelly For Flooring Including Laying, Consolidating, Finishing, Rendering The Top Surface Rough To Receive The Floor, Curing, Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panelling Wherever Necessary And As Directed By The Departmental Officers -Mixing By Manual Means , Brick Work In Cement Mortar 1:3 Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 Including Cost Of Mortar Plasticizer, Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. Brickwork Shall Be Done As Per Is 2212-1991 Adopting English Bond Generally. Other Type Of Bond Shall Be Done As Directed By The Executive Engineer In Charge.-For Foundation & Basement , Brick Work In Cement Mortar 1:5 Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 Including Cost Of Mortar Plasticizer, Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. Brickwork Shall Be Done As Per Is 2212-1991 Adopting English Bond Generally. Other Type Of Bond Shall Be Done As Directed By The Executive Engineer In Charge. , For Foundation & Basement , In Ground Floor , Brick Partition Walls Of 11.50Cm Thickness Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 In Cement Mortar 1:3 (One Cement And Three Cs Sand) Using Hoop Iron Reinforcement If Found Necessary Including Cost Of Mortar Plasticizer, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (Hoop Iron Reinforcement Will Be Measured And Paid For Separately)-In Ground Floor , Damp Proof Course As Per Is 3067:1988 With Cement Mortar 1:4 (One Cement And Four Crushed Stone Sand) 12Mm Thick Mixed With Best Approved Quality Integral Liquid Water Proofing Compound Conforming To Indian Standard Specification As Specified By The Departmental Officers At 2% By Weight Of Cement Used , Finishing And Curing Etc. Complete Complying With Standard Specification - Manual Mixing , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Column Footings, Column Pedestals, Plinth Beams, Grade Beams, Staircase Steps, Sill Slabs Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Of Size 90Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3 Mm For Boarding, Laid With Silver Oak Joists Of Size 10Cm X 5Cm & 7.5Cm X 5Cm As Support Runner , Vertical Stiffener , Side Support And Top Horizontal Stiffener Spaced At About 60Cm To 90Cm Centre To Centre Or At Suitable Intervals Etc. Complete In All Floors Complying With Standard Specifcation. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Plane Surfaces Such As Reinforced Cement Concrete Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks Etc.. With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M(Expandable Upto 3.60M) And Silver Oak Joists Of Size 10 X 5 Cm Spaced At 50Cm To 60Cm C/C And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) Spaced At Not More Than 50 To 60Cm C/C , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces Such As Rectangular Or Square Reinforced Cement Concrete Columns Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Made Of 10 Gauge Thick Welded With Ms Angle Size 40Mm X 40Mm X 5 Mm And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick).Etc..Complete In All Floors Complying With Standard Specifcation. Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Sides And Soffits Including Necessary Supports And Strutting Upto 2.10 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At Abote 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specificaiton And As Directed By The Departmental Officers(Payment For Centering Shall Be Given After The Concrete Is Laid) , Centering For Curved All Reinforced Cement Concrete Surfaces Upto 2.10 M Height , Providing And Laying In Position, Standardised Concrete Mix M-20 Grade By Insitu Machine Mix Concrete Adopting Weighing Batch Method In Accordance With Is 456 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Reinforced Cement Concrete Items Of Works With Minimum Cement Content Of 325 Kg/M3 And Maximum Water Cement Ratio Of 0.55, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Reinforced Cement Concrete Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , In Foundation And Basement , In Ground Floor , Manufacturing, Supplying And Fixing Precast Reinforced Cement Concrete Slabs Of 50Mm Thickness In Reinforced Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Aggregates), Using 20Mm Hbgs Jelly Excluding Cost Of Reinforcement Steel In Position But Including Cost Of Moulding Charges, Casting Of Slab, Finishing, Curing And Fixing In Position In All Floors Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.50Mm Thick Precast Slab , Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Reinforcement Grills Of All Variety Like Hysd/Ctd/Tmtand All Grade Like Fe 500, Fe550d, Fe 500 D Etc., For All Reinforced Cement Concrete Works As Per Design Given Including Cost Of Steel Reinforcement And G.I. Binding Wire, Wastage Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers.(Contractor Has To Make His Own Arrangements For The Supply Of Steel Reinforcement And Binding Wire) , For Foundation And Basement , In Ground Floor , Plain Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Hard Broken Stone Jelly) Using 20Mm Jelly For Wearing Coat Including Laying, Compacting, Finishing And Curing, Etc., Complete As Per Standard Specificatins And As Directed By The Departmental Officers.- Mixing By Manual Means -In Foundation And Basement , Weathering Course In Brick Jelly Lime Concrete Using Broken Brick Jelly Of Size 20Mm Uniform Gauge In Pure Slaked Lime (No Crushed Stone Sand To Be Used) To The Proportion Of Brick Jelly To Lime Being 32:12.5 By Volume And Laid Over The Reinforced Cement Concrete Roof Slab In A Single Layer Of Required Slope And Finished By Beating The Concrete With Wooden Beaters Of Approved Pattern, Keeping The Surface Constantly Wet By Sprinkling Lime Jaggery Water, Etc., Complete As Per Standard Specification And As Directed By The Deparmental Officers.-In Ground Floor , Finishing The Top Of Slopped Roof, Sun-Shade With Machine Pressed Ornamental / Decorative Tiles Of Approved Quality Laid In Cement Mortar 1:3, 20Mm Thick Mixed With Wpc At 2% By Weight Of Cement Used And Top Pointed With The Same Red Oxide Mixed Mortar Etc Complete, Complying With Standard Specifications And As Directed By The Departmental Officers. , Paving The Floor With Best Quality Double Charged Vertified Tiles 1200X 600 X 10Mm Of Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick In All Floors With 3Mm Spacer And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Flooring With Italian Marble Slab Of Size 1200 X 600 Of 16 / 18Mm Thick And Above Free From All Defects In All Floors Over A Base Layer Of Cm 1:3, 20Mm Thick. The Marble Slab Shall Be Laid Over The Cement Mortar By Applying White Cement Slurry In Between Base Mortar And Marble Slab And Pointed With White Cement Neatly Including Polishing With Polishing Stone And Oxalic Acid, To Get Perfectly Smooth And Glossy Finish. Including Hire Charges For Polishing Machine And Power Consumption Charges Etc. The Marble Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete. , Paving The Floor With Best Approved Quality Leather Finished Granite Slab Jet Black Of 18-20Mm Thick With Machine Cut Edges Laid Over A Cement Mortar Bed Of 20Mm Thick Using Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) Fixing The Slabs With Required Cement Slurry And Laid In True Right Angles With Minimum Possible Width Of Joints And Pointing The Joints With White Cement Mixed With Mathcing Colouring Pigments Etc., The Granite Stone Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Providing Full Nosing To The Steps Or Platforms To The Granite Slab Of 20Mm Thick Including Neat Finishing, Polishing, Cost Of Powder, Tools Etc As Directed By The Departmental Officers , Flooring With Self Designed Colour Ceramic Tiles Of Size 305 X 305 X 6Mm Of Following Size And Variety Conforming To Is 15622 Laid Over Cement Mortar Bed Of 20 Mm Thick In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) With Required Cement Slurry And Mortar Plasticizer Including Cutting The Tiles To The Required Size With Special Cutter Wherever Necessary, Laying In Position And Pointing With Water Resistant Tile Epoxy Grout At The Rate Of 0.27 Kg. / Sq.M. Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Dadooing Ceramic Tiles Of Size 300Mm X 600Mm X10mm Best Approved Quality, White / Colour Glazed Tiles Set In Cement Mortar 1:2 (One Cement And Two Sand) 10Mm Thick And Pointing The Joints With White Cement Mixed With Colouring Pigments At The Rate Of 0.40 Kg. /Sq.Mneatly In All Floors, Curing, Etc., Complying With Standard Specification And As Directed By The Departmental Officers. , Dadooing With Granite Tiles Of Jet Black Of Suitable Sizes Of Granite Tiles - (Superfine Polished With Machine Cut Edges) Of Size 20 X 10 Or 10 X 10 Or 10 X 06 Of 10 Mm Thick With Machine Cut Edges Laid Over A Cement Mortar Bed Of 20Mm Thick Using Cement Mortar 1:3 (One Cement And Three Sand) Fixing The Slabs With Required Cement Slurry And Laid In True Right Angles With Minimum Possible Width Of Joints And Pointing The Joints With White Cement Mixed With Mathcing Colouring Pigments Etc., The Granite Stone Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Supply And Fixing Of Natural Granite Stone Piller Of 300 Mm Dia With Base Size 550X550x900mm Thick At Bottom With Curving To Be Laid As Per Design Or Directed By Departmental Officers. The Granite Stone Piller And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Paving The Floor With Pre-Polished Concrete Anti-Skid Tiles (Required Shape And Design) Of 20Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick And Pointed With White Cement Mixed With Colouring Pigment At The Rate Of 0.40 Kg. / Sq.M., Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supply And Fixing The Paving Dry Stone Floor With Sadharhali Stone Slab Of Size 1200X300 And 300X300x70mm Thick To Be Laid As Per Design Or Directed By Departmental Officers In Flamed Finish Including Cutting And Levelling The Earth For Landscapping Area Etc., All Completed Complying With Standard Specification. , Providing Granolithic Floor Finish Of The 25Mm Thickness With Plain Cement Concrete 1:2:4 (One Cement, Two Sand And Four Aggregate) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl, Thread Lining, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panelling Wherever Necessary And As Directed By The Departmental Officers)-For 25Mm Thick , Supplying And Fixing In Position Best Approved Of Bis Quality 160Mm Dia Pvc Rain Water Down Fall Pipes Various Dia Having A Pressure Of 4 Kg. / Sq.Cm Including Cost Of Necessry Pvc Shoe, Pvc Bend, Cast Iron Gratings Of Required Diameter And Special Clamps, Brass Screws, Nails, Etc., And Fixing Of Cast Iron Gratings At Junction Of Parapet And The Reinforced Cement Concrete Roof Slab Including Finishing Neatly Etc., Complete. The Rate Shall Be Inclusive Of Cast Of Removable Cast Iron Grating. The Pvc Pipe Shall Be Fixed In Wall With Special Type Of U Clamp At The Centre Of The Pipe Line In Addition To Those For More Than 3.0 Metre Pipe Length, Etc., Complete Complying With Standard Specification. , Supplying & Fixing Of Wpc (Wood Polymer Composite) Door, Frame Extruded With Size 75Mm X 50Mm. The Single Core Door Made Of Rigid Wpc Compound With Minimum Bulk Density Of 900 Kg/ Cub.Mt. & Shore Hardness Of 55. Supplying & Fixing Of Wpc Door Shutter, Extruded As A Single Core Board With Rigid Wpc Compound With The Thickness Of 25Mm (+/- 1Mm) & Minimum Bulk Density Of 550 Kg/ Cub.Mt. & Shore Hardness Of 55. For The Aesthetic Appearance, The Door Shall Be A Printed Digitally On One Side Of The Shutter. The Wpc Door Shall Be Fixed Onto The Wpc Frame With 3 Nos Of 5 Ss Hinges And The Door Shall Have 2 Towerbolt On One Side And 1 Towerbolt Or Aldrop On Other Side For Locking System And 2 Numbers Of Handle On The Either Side Of The Door Shutter, All Made Of Aluminium.The Rate Is Inclusive Of All Materials, Labours, Conveyance And Fixing In Position With All Other Incidential Charges Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officer.( The Materials Quality,Brand, Colour, Shade Should Be Approved By The Executive Engineer Before Use On Works). , Upvc Window Specification: Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Windows Of Casement Type (Open) From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Are Reinforcement With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profiles Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With Over All The Edges Of Frame And Shutter The Shutter Will Be Provided With Espag Multi Power Point Locks And Also It Operates As Handle. The Corners And Joints Should Be Welded And Cleaned. Radiations Free Pin Headed Plain Or Brown Colour Glass 4Mm Thick Should Be Provided To The Shutter And It Should Not Allow Leakage Of Water Even At Most Ranging Storms And Should Have Key Lockable Action, Security Protective Hinges, Strong Locking Systems And As Per Size For Arresting Noise And Energy Loss. The Connecting Mechanism Between Sash And Outer Frame That Enables Opening Of The Window. The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Window Should Be Got Approved From The Executive Engineer Before Use On Work , Upvc Ventilator Specification: Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators Of From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Size Of 60 X 78Mm Both Profiles Are Reinforced With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profile Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With All Over The Edges Of Frame And Shutter. The Corners And Joints Should Be Welded And Cleaned. Radiations Pin Headed Glass 4Mm Thick Should Be Provided In The Louvers. The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Ventilator Should Be Got Approved From The Executive Engineer Before Use On Work , Manufacturing Supplying And Fixing Of Steel Door Single Leaf With The Following Specification Ms Angels Of Size 40X40x6mm Are Used For The Outer Frames And M.S. Angles Of Size 35X35x5mm For The Shutter Frames Stiffeners With 32 X 6Mm M.S Flat Is Provided At Required Intervals In The Shutter Frame. 18-Gauge C.R. Sheet Laid As Panel In The Shutter And Welded Intact. M.S. Flat 18X5mm Is Welded Over The 32 X 6Mm M.S. Flat Sandwitching The C.R. Sheet In Between Additional Stiffeners With 18X5mm M.S. Flat Is Provided Diagonally At The Rear Side Of The Shutter, 3Nos. Of Hinges In Case Of Single Leaf And 6Nos. Of Hinges In Double Leaves Shutter To Be Provided 6Nos. Of Holdfasts 120 Mm In Length Made Of Angle Section Spliced At The Ends Are Welded To The Outer Frames Of The Door. Tower Bolts 2Nos. One At The Top And The Other At The Bottom Are Provided 1No. Aldrop Is Provided Incase Of Double Leaf Door At Lock Rail Section In The Door In Single Leaf Door, One More Aldrop Is Provided In The Inner Lock Rail Section Of The Door One Rotaing Locking Arrangements For The Inner Side Of The Door And Additional Provision For Locking Arrangements For Lock Is Provided On The Rear Side Of The Door At An Appropriate Place. Incase Of Double Leaf Door M.S.Flat 32 X 3Mm At 1.1Kg/M Is Provided On The One Shutter T Conceal The Gap Between The Two Shutters.At An Appropriate Place In The Door. , A Tie Bar Is Provided At The Bottom Of The Frame To Prevent Twisting Of Frame During Transportation And Fixing. All Members Are Given A Coat Of Red Oxide Primer As Directed By The Departmental Officers. The Rate Includes Cost Of All Materials, Labour Charges, Transportation To Site Of Work, Loading, Un Loading And All Other Incidental Charges Etc., Complete.-Single Leaf , Supplying And Fixing Of M.S.Grill Of Approved Design For Grill Gate, Grill Work To Doors And Windows Openings Ramp Etc., Using Necessary Mild Steel Flats For Inner And Outer Members Which Should Be Fixed On Edges Including Priming Coat Of Best Approved Quality Red Oxide Primer Etc., Complete Complying With Standard Specification. , Supplying And Laying Rubber Moulded Hydraulic Pressed Paver Block Of 83Mm Thick Approved Design Made Out Of 6 - 10Mm Thick Hbgs Chips In Cm 1:2:4 Properly Occurred To Attain The Required Strength Laying The Rubber Moulded Paver Block Over A Sand Cushion Of 10Cm Thick And Well Compacted Using 1-3 Tonne Capacity Of Manufacturing The Inter Locking Blocks , Loading, Transportation , Unloading And Other Incidential Charges Etc. Complete Complying With Standard Specification , Plastering With Cement Mortar 1:5 (One Cement And Five Sand), 12Mm Thick In All Floors Including Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Special Ceiling Plastering And Finishing The Exposed Surface Of All Reinforced Cement Concrete Items Of Work Such As Slabs, Beams, Sunshades, Facia, Canopy Slab, Staircase Waist Slab, Landing Slab Etc., With Cement Mortar 1:3 (One Cement And Three Sand) 10Mm Thick Used Finishing Including Hacking The Surfaces, Providing Cement Mortar Nosing, Beading For Sunshades, Staircases, Steps, Landing Slabs And Curing, Etc., In All Floors Complying With Standard Specification And As Directed By The Departmental Officers , Plastering The Surface Of Walls With Cement Mortar 1:3 (One Cement And Three Sand), 12Mm Thick Used Finishing In All Floors Including Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification. , Painting The Wall Two Coats With Approved Weather Proof Exterior Emulsion Paint Over One Primer Coat Of Over Cement Plastered Wall Surface Ect., Complete Complying With Standard Specification. , Painting New Iron Works Such As Steel Doors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approved First Quality And Colour Of Synthetic Enamel Paint Over The Existing Red Oxide Priming Coat In All Floors Excluding Cost Of Priming Coat Etc., Complete Complying With Standard Specification. , Supplying, Laying And Jointing Cpvc Pipes Of Standard Dimension Ratio 11 (Pressure Class 1) Conforming To Is:15778 - 2007 Of Approved Quality And Best Variety Of The Following Dia Including Cutting And Fixing Cpvc Specials Using Cpvc Adhesives (Solvent Cement) (But Excluding Cost Of Such Specials) And Fixing Into Wall With Teak Wood Plugs, Cpvc Clamps And Screws Making Holes On The Wall (Or) Drilling Holes In The Roof And Making Good The Dismantled Portion To Original Condition With Necessary Brick Work / Cement Concrete And Plastering Neatly Wherever Necessary With Necessary Scaffolding Charges, Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. (The Cpvc Pipes Shall Be Got Approved By Executive Engineer Before Use On Works) - Internal Water Supply Above Ground Level.25 Mm Dia Cpvc Pipe , Supplying Cpvc Specials Of Sdr 11 Conforming To Is 17546-2021 In Water Supply Arrangements (Both In Internal And External Water Supply Arrangements , 25 Mm Dia Cpvc Elbow , 25 Mm Dia Cpvc Tee , 25 Mm Dia Cpvc Union , 25 Mm Dia Upvc Nipple , Supplying, Laying And Jointing Upvc Pipes Of Class 6 (Having Working Pressure Of 10 Kg/Sq.Cm) Conforming To Is 4985- 2000 Of Approved Quality And Best Variety Of The Followingdia Including Cutting And Fixing Upvc Specials Using Upvc Adhesives (But Excluding Cost Of Such Specials) In Accordance With Is 7634-3 (2003) And Fixing Into Wall With Teak Wood Plugs, Pvc Clamps And Screws Making Holes On The Wall (Or) Drilling Holes In The Roof And Making Good The Ismantled Portion To Original Condition With Necessary Brick Work / Cement Concrete And Plastering Neatly Wherever Necessary With Necessary Scaffolding Charges Upto 4 Metre Height Above Ground Level, Etc., Complete Complying With Standard Specifications. The Pvc Pipes Shall Be Got Approved By Executive Engineer Before Use On Works - External Water Supply Above Ground Level , 25 Mm Dia Upvc Pipe , 32 Mm Dia Upvc Pipe , 40 Mm Dia Upvc Pipe , 50 Mm Dia Upvc Pipe , Supplying Upvc Specials (With Working Pressure 10 Kg. / Sq.Cm.) In Water Supply Arrangements (Both In Internal And External Water Supply Arrangements , 25 Mm Dia Union , 32 Mm Dia Union , 40 Mm Dia Union , 50 Mm Dia Union , 25 Mm Dia Elbow , 32 Mm Dia Elbow , 40 Mm Dia Elbow , 50 Mm Dia Elbow , 25 Mm Dia Tee , 32 Mm Dia Tee , 40 Mm Dia Tee , 50 Mm Dia Tee , 32 X 25 Mm Dia Reducer , 25 X 20 Mm Dia Reducer , 20 X 15 Mm Dia Reducer , Supplying And Fixing In Position First Quality And Approved Variety Of Gun Metal Gate Valve / Wheel Valve With Bis Make Of The Following Dia Including Cost Of Shellac, Thread Balls, Etc., Complete Complying With Standard Specifications (For Both Internal And External Water Supply Arrangements). The Valves To Be Used On Work Shall Be Got Approved By The Executive Engineer Before Use On Work. , 25 Mm Dia G.M. Gate Valve , 32 Mm Dia G.M. Gate Valve , 40 Mm Dia G.M. Gate Valve , 50 Mm Dia G.M. Gate Valve , Supplying And Fixing In Position White Glazed European Water Closet 10 Litre Capacity Pvc Flushing Tank Fixed On To Wall Of Best Quality And Approved Make With 100 Mm P Or S Trap Connecting With Pvc Pipe Of 110Mm Dia, Double Flapped Rigid Pvc Black Seat And Seat Cover With Cp Brass Hinges Including Cost Of White Cement, Cement For Packing, Spun Yarn, Teak Wood Plugs, Brass Screws, Etc., Including Supplying And Fixing 10 Litres Capacity Pvc / 12.5 Litres Capacity Porcelin Low Level Flushing Tank With A Pair Of Ci Brackets, Etc., Complete With All Fittings Such As 15Mm Brass Ball Valve With Polythene Float With Brass Handle, Union, Coupling Connected By Means Of 40Mm White Pvc Flush Hand Using Indian Adopter Joint Including All Internal Fittings Such As 15Mm Brass Connections, 15Mm Gm Wheel Valve, 15Mm Brass Nipple (2 Nos.), 15Mm Nylon Connection, Tw Plugs, Screws And Also Giving Necessary Connection To The Pvc Pipe Including Cost Of 600Mm Length Of 110Mm Dia Pvc Pipe And Painting The Ci Brackets With 2 Coats Of Approved Paint Over One Coat Of Red Oxide Primer, Dismantling The Masonry And Re-Doing The Dismantled Masonry To Original Condition Etc. Complete Complying With Standard Specifications. Colour Glazed European Water Closet With 10 Litre Capacity Pvc Flushing Tank Fixed With Ci Brackets , Supplying And Fixing In Position Best Quality And Approved Make Indian Made White / Colour Glazed Earthernware Wash Hand Basin Of Size 550 X 400Mm (With Pedestal / Without Pedestal) With A Pair Of Cast Iron Brackets, Including Cost 15Mm Dia Brass Cp Pillar Tap, 32Mm Dia B Class Gi Waste Pipe With Rubber Plug And Chain, 15Mm Dia Gm Wheel Valve, 15Mm Brass Nipple, 15Mm Dia Nylone Connection, 32Mm Dia Cp Brass Waste Coupling Including Fixing Of Wash Basin Using Ci Brackets On To The Wall In Position With Tw Plugs And Screws, Rubber Washers, White Lead And Giving Necessary Water Supply Connection And Painting The Brackets With Two Coat Of Painting Over A Priming Coat Of Anti-Corrosive Paint Including Testing For Leakages Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Wash Hand Basin And Specials Should Be Got Approved By The Executive Engineer Before Use On Works).-Colour Glazed Wash Hand Basin A) Without Pedestal , Supplying And Fixing In Position Indian Make Bevelled Edge Mirror Of Approved Quality And Brand Pvc / Fibre Glass Framed 600 X 450 X 5.5Mm Thick Mirror, Shelf Type With Hard Board Backing Of Approved Colour Fixed With Brass Screws, Rawl Plug, Etc., Complete Complying With Standard Specification , Supplying And Fixing Best Approved Best Quality Brass Cp Soap Tray Of Size 150 X 100Mm Including Cost Of Teak Wood Plugs, Brass Screws, Etc., Complete Complying With Standard Specifications. , Supplying And Fixing Approved Best Quality Brass Cp Towel Rail 600Mm Long And 20Mm Dia With Brackets Of Same Materials Including Cost Of Teak Wood Plugs And Cp Screws, Etc., Complete Complying With Standard Specifications. , Supplying And Fixing In Position 15Mm Dia Brass Cp Screw Down Tap (Heavy Duty) Of Approved Make Conforming To Bis Specifications And Quality Including Cost Of Shellac, Thread, Etc., Complete Complying With Standard Specification And Including Cutting And Threading Wherever Necessary , Supplying And Fixing In Position Best Quality Pvc Soil / Waste Pipes Of Various Dia Having 6 Kg / Sq.Cm. Pressure Bis Mark And Providing Leak Proof Joints Using Pvc Adhesives Including Fixing To The Wall With Special Pvc / Ms Clamp, Teak Wood Plugs, Brass Screws, Etc., And Making Connection To All Sanitary Fittings, Dismantling Masonry / Reinforced Cement Concrete Works Wherever Found Necessary And Making The Good Dismantled Portion To The Original Condition, Including Testing For Any Leakages, Etc., Complete Complying With Standard Specifications. (The Pvc Pipes Should Be Got Approved By The Executive Engineer Before Use On Works). The Rate For Earth Work Excavation Will Be Measured And Paid Separately In The Cases Where The Pipe Lines Are Proposed To Laid Below Ground Level , 75Mm Dia Pvc Soil / Waste Pipe , 110Mm Dia Pvc Soil / Waste Pipe , Supplying And Fixing In Position Pvc Specials Of The Following Dia And Types Of Approved Quality Confirming To Bis And Providing Leak Proof Joints Including Fixing To The Walls And Giving Connection To The Pvc Soil Stacks, Dismantling The Masonry Or Reinforced Cement Concrete Works And Re-Doing The Dismantled Portion To Original Condition Etc., Complete Complying With Standard Specifications. , 75Mm Dia Pvc Elbow , 75Mm Dia Pvc Tee , 75Mm Dia Pvc Tee With Single Door , 75Mm Dia Pvc Bend , 110Mm Dia Pvc Elbow , 110Mm Dia Pvc Tee , 110Mm Dia Pvc Tee With Single Door , 110Mm Dia Pvc Bend , Supplying And Fixing Position Pvc Nahani Trap / Floor Trap Of The 100 X 75Mm With Pvc Gratings Sizes With Best Stainless Steel Gratings Of Approved Brand And Quality, Fixed Over A Bed Of Brick Jelly Lime Concrete 1:2:5 (One Part Of Lime, Two Part Of Sand And Five Part Of 40Mm Gauge Brick Jelly) And Finished With Cement Mortar 1:3 (One Cement, Three Sand) Including Dismantling Masonry Works Wherever Found Necessary And Making Good The Dismantled Portions To The Original Condition And Giving Connection To The Pvc Pipes, Etc., Complete Complying With Standard Specification. , Supplying And Fixing Pvc Ventilating Shaft Of 110Mm Dia (Having Working Pressure 4 Kg. / Sq.Cm) With 3 Metre Height Including Cost Of Pvc Cylindrical Cowl Of Best Approved Quality Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers , Supplying And Fixing In Position Ci Manhole Covers With Ci Frames (Heavy Duty) Of Size 60Cm X 60Cm Of Best Approved Quality As Per Standard Specification Etc., Complete Compying With Standard Specifications , Supplying And Filling 20Mm Guauge Hbgs Stone Jelly For Dispersion Trench Including Loading Conveying And Unloading And As Directed By The Departmental Officers Etc. Complete Complying With Standard Specification. , Supplying And Filling 40Mm Guauge Hbgs Stone Jelly For Dispersion Trench Including Loading Conveying And Unloading And As Directed By The Departmental Officers Etc. Complete Complying With Standard Specification. , Drilling 150Mm Dia Vertical Bore Using Power Drill In Hard Rock To Any Required Depth As Directed By The Departmental Officers Including Labour Charges For Inserting Casing Pipes To The Require Depth Assembly In Drilled Hole Including Welding The Joint If Necessary, Grouting The Casing Pipe Etc., And Including Transportation Charges For The Rig And Support Vehicle. , Up To 150M Below Ground Level , From 151M Up To 180M , From 181M Up To 210M , From 211M Up To 240M , Supplying And Fixing Of Pvc Casing Pipe 160Mm Dia Suitable For 6 Borewell Conforming To I.S. 12818 - 1992 With Screwed And Socked And Centering Guides For Every 15M Interval Etc., As Directed By The Departmental Officers. [With / Without Slot] , Supply Suitable Pvc End Cap (6Kg/Sqcm) Of Best For Casing Pipe Of 6 Dia Borewell Quality With Isi Mark, The Pvc Should Got Approved By The Departmental Officers. , Supply And Run Off Water Proof 3 Core 4 Sq.Mm Flat Pvc Insulated Copper Cable For Submersible Pumpset In The Borewell Including Fixing And Tying With Copper Wire And Clamping Water Pipe Etc., Complete As Directed By The Departmental Officers. , Supplying And Fixing 40 Mm Dia Upvc Pipe Of Best Quality For Delivery Cum Support Pipe For Submersible Motor Inside Borewell Etc., Complete As Directed By The Departmental Officers. A) 40 Mm Dia Pipe , Supplying And Fixing Of Nylon Rope For Submersible Motor Of Approved Quality In Etc,Complete Complying With Standard Specifications. , Supplying And Erecting Isi Make Submersible Pump Of 7.5 Hp/ 5.0 Kw Model Csm-9 With Outer Dia 50Mm Of Is 14220 Specification With Submersible S/D Starter Of 8.9 - 13.50 A Rekat Range With 13.5 A Rating And 380-415 V Ac Coil Voltage As Per Specification. Providing Necessary Panel Board With Dol Bush Button Starter With Over Load Relay Three Phase Preventer Indicating Lamps On/Off Switches-1 No Automanual Selection Switch Complete As Directed Etc, Complete. Including Panel Board. , Supplying And Fixing Wall Mounting Of Panel Board With Following Accessories A.Suitable Dol Type Push Botton Automatic Starter Etc., Complete. , Supplying And Erecting 2H.P Monoblock With Isi Mark With Necessary Accessories (Motor Should Be Got Approved By Executive Engineer Before Use Onworks) Complete Complying With Standard Specification. , Supplying And Fixing Of Pvc Readymade Water Tank (1000Lit) Of Best And Approved Quality With Isi Specification Labour For Fixing Etc., Complete.Should Be Got Approved By The Executive Engineer Before Use On Works , Providing Anti-Termite Treatment To Soil Adjecent And Under Building Foundation, Plinth Periphery Of The Building By Application Of Chemicals Of Is 63613 Part I To Iv In Stages To Suit The Progress Of Work Consist As Per The Detailed Specification As Below. Including Breaking Of Termite Mounds, Making Holes With Crow Bar, Closing The Holes After The Treatment And Including Cost Of Chemicals, Labour Charges, Transport And Storing Etc., Complete And As Directed By The Departmental Officers. , Gst
Contract Date: Mar 13, 2026 Contract Value : 1.99 Crore
Government Departments No of Bidders 3
48.
Housing Urban and Rular Development #9786076 Price Bid
Tender For Mow/Deposit Work Under Jail-3 Sub Dn, Pwd Bhopal-1 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. 1.2.1 Lime, moorum, building rubbish 1.2.2 Earth 1.2.3 Manure or sludge 1.2.4 Excavated rock 1.2.5 Sand, stone aggregate below 40mm nominal size 1.2.6 Stone aggregate 40mm nominal size and above 1.2.7 Stone soling 1.2.8 Bricks 1.2.9 S.W. Pipes 1.2.9.1 100 mm dia 1.2.9.2 150 mm dia 1.2.9.3 200 mm dia 1.2.9.4 250 mm dia 1.2.9.5 300 mm dia 1.2.9.6 350 mm dia 1.2.9.7 400 mm dia 1.2.9.8 450 mm dia 1.2.9.9 500 mm dia 1.2.9.10 600 mm dia 1.2.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and reinforced cement pipes 1.2.10.1 100 mm dia 1.2.10.2 125 mm dia 1.2.10.3 150 mm dia 1.2.10.4 200 mm dia 1.2.10.5 250 mm dia 1.2.10.6 300 mm dia 1.2.10.7 350 mm dia 1.2.10.8 400 mm dia 1.2.10.9 450 and 500 mm dia 1.2.10.10 600, 700, 750 and 800 mm dia 2 1.3 Add extra for every additional lead of 50 metre or part thereof. 1.3.1 Lime, moorum, building rubbish 1.3.2 Earth 1.3.3 Manure or sludge 1.3.4 Excavated rock 1.3.5 Sand, stone aggregate below 40mm nominal size 1.3.6 Stone aggregate 40mm nominal size and above 1.3.7 Stone soling 1.3.8 Bricks 1.3.9 S.W. Pipes 1.3.9.1 100 mm dia 1.3.9.2 150 mm dia 1.3.9.3 200 mm dia 1.3.9.4 250 mm dia 1.3.9.5 300 mm dia 1.3.9.6 350 mm dia 1.3.9.7 400 mm dia 1.3.9.8 450 mm dia 1.3.9.9 500 mm dia 1.3.9.10 600 mm dia 1.3.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and unreinforced cement pipes 1.3.10.1 100 mm dia 1.3.10.2 125 mm dia 1.3.10.3 150 mm dia 1.3.10.4 200 mm dia 1.3.10.5 250 mm dia 1.3.10.6 300 mm dia 1.3.10.7 350 mm dia 1.3.10.8 400 mm dia 1.3.10.9 450 and 500 mm dia 1.3.10.10 600, 700, 750 and 800 mm dia 3 2.1 Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. 2 2.2 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 5 2.3 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 6 2.4 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.4.1 beyond 30 cm girth up to and including 60 cm girth 2.4.2 beyond 60 cm girth up to and including 120 cm girth 2.4.3 beyond 120 cm girth up to and including 240 cm girth 2.4.4 above 240 cm girth 7 2.5 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil 8 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil 9 2.7 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. 2.7.1 Ordinary rock 2.7.2 Hard rock (requiring blasting) 2.7.3 Hard rock (blasting prohibited) 10 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means)Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-InCharge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day 2.8.1 Ordinary rock 2.8.2 Hard rock (requiring blasting) 2.8.3 Hard rock (blasting prohibited) 11 2.9 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil 2.9.1 Pipes, cables etc., not exceeding 80 mm dia. 2.9.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.9.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. 12 2.10 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). 13 2.11 Extra for excavating trenches for pipes, cables, etc., in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 14 2.12 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m including including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : 2.12.1 Ordinary rock : 2.12.1.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 2.12.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600mm dia 2.12.2 Hard rock (requiring blasting) 2.12.2.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.2.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.2.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia 2.12.3 Hard rock (blasting prohibited) 2.12.3.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.3.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia. 15 2.13 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 16 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 17 2.15 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.15.1 Depth not exceeding 1.5 m. 2.15.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.15.3 Depth exceeding 3 m but not exceeding 4.5 m. 18 2.16 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 2.16.1 Depth not exceeding 1.5 m. 2.16.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.16.3 Depth exceeding 3 m but not exceeding 4.5 m. 19 2.17 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered) : 2.17.1 Depth not exceeding 1.5 m. 2.17.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.17.3 Depth exceeding 3 m but not exceeding 4.5 m. 20 2.18 Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be leftpermanently in position. (Face area of timber permanently left to be measured). 21 2.23 Extra rates for quantities of works, executed: 2.23.1 In or under water and/or liquid mud, including pumping out water as required. 2.23.2 In or under foul position, including pumping out water as required. Note: - The extra percentage rate is applicable in respect of each item but limited to quantity executed in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre and less than 0.05 metre ignored. 22 2.24 Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 23 2.25 Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) 2.25.1 All kinds of soil. 2.25.2 Ordinary or hard rock. 24 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. 25 2.27 Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. 26 2.28 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then refiling the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5m. 2.28.1 All kinds of soil. 2.28.2 Ordinary rock 2.28.3 Hard rock (requiring blasting) 2.28.4 Hard rock (blasting prohibited) 27 2.29 Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) 28 2.30 Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.30.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. 29 2.31 Deduct for disposed soil not levelled and neatly dressed. 30 2.32 Preconstruction antitermite treatment to the building under construction by providing.Stage 1: Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. 31 2.33 Making bore holes for providing dowel bars at designed depth in rock foundation by drilling 40 mm dia bore hole in rock including necessary bending hooking, in position and grouting with cement slurry etc. complete as per drawing and specification. (Steel to be paid separately). 32 2.34 Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. 33 2.35 Earth work in rough excavation by any means and bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne in embankments for roads, flood banks, marginal bank and guide bank of filling up ground depression within campus, lead upto 50m and all lift. All kinds of soil. 34 2.36 Bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammers etc. and rolling every 3rd and top-must layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal bank and guide bank etc. lead upto 50m and lift upto 1.5m. All kinds of soil. 35 2.37 Deduct for not rolling with power roller of minimum 8 tonnes for bankingfilling excavated earth in layers not exceeding 20cm in depth. 36 2.38 Deduct for not watering with the excavated earth for bankingfilling 37 2.39 Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30 cm interval in the tube,. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in- charge with bond of 5 year warranty. 2.39.1 Permanent piping system with Junction boxes 2.39.2 Anti-termite chemical injected area 38 2.40 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (All kinds of soil) 39 3.1 Cement mortar 1:1 (1 cement: 1 sand) 40 3.2 Cement mortar 1:2 (1 cement: 2 sand). 41 3.3 Cement mortar 1:3 (1 cement: 3 sand). 42 3.4 Cement mortar 1:4 (1 cement: 4 sand). 43 3.5 Cement mortar 1:5 (1 cement: 5 sand). 44 3.6 Cement mortar 1:6 (1 cement: 6 sand). 45 3.7 Cement mortar 1:2 (1 cement: 2 stone dust). 46 3.8 Cement mortar 1:2 (1 cement: 2 marble dust). 47 3.9 White cement mortar 1:2 (1 white cement: 2 marble dust). 48 3.10 Cement mortar 1:5 (1 cement: 5 marble dust). 49 3.11 White cement mortar 1:3 (1 white cement: 3 marble dust). 50 3.12 White cement mortar 1:5 (1 white cement: 5 marble dust). 51 3.13 Mortar in lime , surkhi (50% red and 50% light yellow) and marble dust 1:1.5:0.5 52 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete 4.1.1.2 M-20 – Grade concrete 4.1.1.3 M-15 – Grade concrete 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate 4.1.3 With fly ash. 4.1.3.1 1:2:3½:9 (1 ordinary Portland cement : 2 Fly ash : 3½ sand: 9 graded stone aggregate 40 mm nominal size) 4.1.3.2 1:2½:4:11 (1 ordinary Portland cement : 2½ fly ash : 4 sand : 11 graded stone aggregate 40 mm nominal size) Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 53 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete 4.2.1.2 M 20 – Grade concrete 4.2.1.3 M 15 – Grade concrete 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 54 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. 4.3.3 Above plinth: Columns, pillars, posts and struts. 55 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . 4.4.1 M-15 (With 20mm nominal size graded stone aggregate) 4.4.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 56 4.5 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement morta1:3 (1 cement : 3 sand) on exposed surfaces complete.(With 20mm nominal size graded stone aggregate) 57 4.6 Providing and fixing upto floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 sand) on exposed surfaces complete. 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 58 4.7 Providing and fixing upto floor two level precast cement concrete solid block including hoisting and setting in position with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete : 4.7.1 M-15 (With 20mm nominal size graded stone aggregate) 4.7.2 M-10 (M 10) (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 59 4.8 Providing and Fixing upto floor two level pre cast concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete. 4.8.1 M-15 (With 20mm nominal size graded stone aggregate) 4.8.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 60 4.9 Add extra for item no. 4.6, 4.7 and 4.8 above floor two level for every additional floor or part there of 61 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). 62 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size). 63 4.12 Extra for providing and mixing water proofing material as per IS standard in cement concrete work quantity as prescribed by the manufacturer. 64 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 65 4.14 Extra for concrete work in superstructure above floor two level for each floors or part thereof 66 4.15 Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.Note for item No. 4.15:- The quantity will be calculated by multiplying. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored. 67 4.16 Extra for laying concrete in or under foul positions. 68 4.17 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) 69 4.18 Extra for addition of synthetic polyester triangular fiber of length 12 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/ Water retaining structures by using 125 gms of synthetic polyester triangular fibre for 50 kgs cement used as per directions of Engineer-in- Charge. 70 4.19 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 71 4.20 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 72 4.21 Providing and fixing up to floor two level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete . 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 73 4.22 Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 74 4.23 Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : (1) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacemen to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. 4.23.1 All works up to plinth level: 4.23.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.23.2 All works above plinth and upto floor two level 4.23.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 75 4.24 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge. 4.24.1 All works up to plinth level: 4.24.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.24.2 All works above plinth and upto floor two level 4.24.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 76 4.25 Plum Cement concrete 1:2:4 with 75% graded metal of maximum size 40 mm and 25% plum of 150mm size. 77 4.26 Providing and laying cement concrete in Sunken floors of WC, Toilet, Wash Area, etc with 1:5:10 (1 cement : 5 coarse sand (zone-3) : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering 78 5.1 Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M-20 Grade Concrete 5.1.2 M-15 Grade Concrete 79 5.2 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: 5.2.1 M-20 Grade Concrete 80 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. 5.3.1 M-20 Grade Concrete 81 5.4 Providing and laying upto floor two level reinforced cement concrete (with20 mm nominal size graded stone aggregate) in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with Concrete grade. 5.4.1 M-20 Grade Concrete 82 5.5 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in arches, archribs, domes, vaults, shells, folded plate above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in Concrete grade. 5.5.1 M-20 Grade Concrete 83 5.6 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in chimneys, shafts, upto floor two level excluding the cost of centring, shuttering, finishing and reinforcement with 5.6.1 M-20 Grade Concrete 88 5.7 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in well-steining excluding the cost of centering, shuttering, finishing and reinforcement with 5.7.1 M-20 Grade Concrete 84 5.8 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in vertical and horizontal fins individually or forming box louvers, facias and eaves boards up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in M 20 –Grade Concrete 85 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. 5.9.2.2 Above plinth upto 3.6 m height from plinth level 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. 5.9.3 Suspended floors, roofs, landings, balconies and access platform. 5.9.4 Shelves(Cast in situ) 5.9.5 Lintels, beams, girders, bressumers and cantilevers 5.9.6 Columns, P i l l a r s , Piers, Abutments, Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. 5.9.8 Spiral staircases (including landing). 5.9.9 Arches, domes,vaults upto 6m span 5.9.10 Extra for arches, domes, vaults exceeding 6 m span 5.9.11 Chimneys and shafts 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. 5.9.13 Well steining 5.9.14 Vertical and horizontal fins individually or forming Box louvers band, facias and eaves boards. 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. 5.9.17 Cornices and mouldings 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of S.E. in case of B & R works and from Additional Project Director in case of PIU works) 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of S.E. in case of B&R works and from Additional Project Director in case of PIU works) 86 5.10 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 87 5.11 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. 88 5.12 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 sand) etc. complete excluding plastering of the jambs, sills and soffits. 5.12.1 50 mm thick 5.12.2 40 mm thick 5.12.3 25 mm thick 89 5.13 Encasing rolled steel sections, in beams and columns, with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) including centering and shuttering complete but excluding cost of reinforcement. 80 5.14 Encasing rolled steel section in grillages with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including centering and shuttering but excluding cost of expanded metal and hangers. 91 5.15 Extra for providing and fixing expanded metal mesh of size 20x60mm and strands 3.25mm wide 1.6mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. 92 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.1 Mild steel and Medium Tensile steel bars. 5.16.2 Hard drawn steel wire 5.16.3 Cold twisted bars (CTD) 5.16.4 Hot rolled deformed bars 5.16.5 Hard drawn steel wire fabric 5.16.6 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 93 5.17 Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. 94 5.18 Providing and fixing in position copper plate as per design for expansion joints. 95 5.19 Providing and filling in position, blown bitumen in expansion joints. 96 5.20 Providing and filling in position bitumen mix filler of Proportion 80 kg. Of hot bitumen, 1 kg. Of cement and 0.25 cubic metre of sand for expansion joints. 97 5.21 Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/ Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth. 98 5.22 Providing and fixing in position bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. 5. 22.1 12 mm thick 5. 22.2 25 mm thick 5. 22.3 50 mm thick 99 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. 5. 23.1.2 200mm wide. 5. 23.1.3 250mm wide. 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. 5. 23.2.2 200 mm wide. 5. 23.2.3 250 mm wide. 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. 5. 23.3.2 200 mm wide. 5. 23.3.3 250 mm wide. 100 5.24 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 101 5.25 Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.Note- For Item No. 5.25:-The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub – soil water condition 102 5.26 Extra for laying reinforced cement concrete in or under foul positions. 103 5.27 Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. 5.27.1 All works upto plinth level. 5.27.2 All works above plinth level and upto floor five level. 5.27.3 Add extra for each floor for all works above floor five level. 104 5.28 Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) 5. 28.1 Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum) 5. 28.2 Providing M-30 grade concrete instead of M- 25 grade.(Note : minimum cement content is @ 340 kg/cum) 5. 28.3 Providing M-35 grade concrete instead of M- 25 grade.(Note: : minimum cement content is @ 350 kg/cum) 5. 28.4 Providing M-40 grade concrete instead of M- 25 grade.(Note: minimum cement content is @ 360 kg/cum) 105 5.29 Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement. 106 5.30 Providing and laying in position ready mixed concrete (RMC) of M-25 grade for reinforced cement concrete work, using cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.Note: Minimum cement content is @ 330 kg/cum. (No extra payment for using extra cement as per requirement of mix design.) 5.30.1 All works upto plinth level. 5.30.2 All works above plinth level and upto floor V level. 5.30.3 Extra for each additional floor for all works above floor five level 107 5.31 Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.27 and 5.30) 108 5.32 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. 5.32.1 Non pigmented wet curing compound 5.32.2 Pigmented wet curing compound. 109 5.33 Providing and fixing in position factory made precast RCC M-40 doors, windows and ventilator frames having excellent smooth finish, as per IS: 6523 with 6mm dia main reinforcement each polymer block having at least four holes for passing one or adjacent rebates to hold fast grill or steel bar, ventilator frame provided with grooves for louvers at an angel of 45 degree at spacing to block direct vision etc. complete, as per the direction of Engineer-in-charge. The cost of hold fast and cement concrete block of 1:3: 6 (1 Cement: 3 sand: 6 Graded stone aggregate 20mm nominal size) mix is also included in the item. 5. 33.1. Frame 125 mmx 60 mm (double rebate) 5. 33.2. Frame 100mmx 60 mm (Single rebate) 5. 33.3 Frame 85mmx 60 mm (Single rebate) 110 5.34 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand). 111 5.35 Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 5. 35.1 12 mm thick 5. 35.2 25 mm thick. 5. 35.3 50 mm thick. 112 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. 113 5.37 Providing and fixing sheet covering over expansion joints with iron screws as per design. Non- asbestos cement bonded particle board 6 mm thick as IS: 14276 5.37.1 150mm wide 5.37.2 200mm wide 5.37.3 250mm wide 114 5.38 Providing & laying in position Prestressing steel strands (low relaxation) on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master including all accessories for Stressing &destressing operations as per approved make conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of Engineer -in- charge. 115 5.39 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer - inCharge. (Material shall confirm to ASTM 6063). 5. 39.1 Floor Joint of 100 mm gap 5. 39.2 Floor Joint of 150 mm gap 5. 39.3 Floor Joint of 200 mm gap 116 5.40 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 5. 40.1 Wall Joint of 100 mm gap 5. 40.2 Wall Joint of 150 mm gap 5. 40.3 Wall Joint of 200 mm gap 117 5.41 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centeringarragement support plates asper ASTM B221-02. . The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 5.41.1 Roof Joint for 100 mm gap 5.41.2 Roof Joint for 150 mm gap 5.41.3 Roof Joint for 200 mm gap 118 5.42 Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) 119 6.1 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc. complete. 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) 120 6.2 Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc. complete. 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) 121 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). 122 6.4 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). 123 6.5 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). 124 6.6 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) 125 6.7 Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) 126 6.8 Brick work with calcium silicate bricks machine moulded conforming to IS:4139, having 100 kg/cm2 average compressive strength in super structure above plinth level upto floor II level in : 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) 127 6.9 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885 ) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) 128 6.10 Brick work with extruded burnt fly ash clay sewer bricks (conforming to IS: 4885) in archesin foundation and plinth including centering and shuttering complete in cement mortar 1:3 (1 cement: 3 sand). 129 6.11 Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item. 130 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) 131 6.13 Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) 132 6.14 Providing half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) 133 6.15 Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) 134 6.16 Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. 135 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. 136 6.18 Honey-comb brick work 10 cm thick with well burnt chimney bricks manufactured by ghol process crushing strength not less than 40kg /sqcm and water absorption not more than 15% in cement mortar 1:4 (1 cement : 4 sand). 137 6.19 Extra for forming cavity 5cm to 7.5cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. Ties 300mm long of 25x3mm section at not less than 3 ties per sqm as per approved design 138 6.20 Brick work in plain arches in superstructure including centering and shuttering complete with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 cement : 3 sand). 139 6.21 Brick work in gauged arches in superstructure in cement mortar 1:3 (1 cement : 3 sand) including centering and shuttering complete, with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% 140 6.22 Providing half brick masonry with kiln burnt clay bricks of 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 Cement : 3 sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm wide bitumen felt type 3 grade 1. 141 6.23 Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of brick work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 142 6.24 Extra for laying brick work in or under foul position. 143 6.25 Providing and laying cellular concrete blocks masonry having density ranging from 800kg/m3 in super structure above plinth level up to floor two level in cement mortar 1:4 (1 cement: 4 sand) The nominal dimensions of the concrete blocks shall be as follows in additional block shall be of half lengths of 200, 250 or 300 mm to correspond to the full lengths. The size of the blocks specified other than those specified may also be used. 144 6.26 Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM international standard including raking out joints. Vertical bands shall be placed along jams (vertical member of chowkhats) and extend upto lintel levels to arrest cracking at corner openings. RCC bands shall be measured with AAC block masonry. Rates include all materials including steel bars, wastages, scaffolding and all labour etc. complete. 6.26.1 AAC Masonry in polymer modified mortar 145 6.27 Extra for AAC masonry work in superstructure above floor two level for each additional floor or part thereof 146 6.28 Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. 147 6.29 Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels. Quantity of reinforcement steel in AAC panels shall be ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. 148 6.30 Add extra for AAC wall panels, roof slabs, lintels and chhajjas above floor two level for each additional floor as per item no 6.29 and 6.30. 149 6.32 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 6.32.1 From ground level upto plinth level 6.32.2 Above plinth level upto floor II level 150 6.33 Brick work with modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level up to plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) 6.33.1 From ground level upto plinth level 6.33.2 Above plinth level upto floor II level 151 6.34 Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor two level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 152 6.35 Extra for Gypsum panel Partitions in superstructure above floor two level for every four floors or part thereof. 153 7.1 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 sand) 154 7.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. 7.2.1 Cement mortar 1:6 (1cement: 6 sand). 155 7.3 Extra for random rubble masonry with hard stone in superstructure above floor two level for every floors or part thereof 156 7.4 Extra for random rubble masonry with hard stone in : 7.4.1 Square or rectangular pillars 7.4.2 Circular pillars. 157 7.5 Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. 158 7.6 Coursed rubble masonry (1st or 2nd sort) with hard stone in foundation and plinth. 7.6.1 Cement mortar 1:6 (1 cement : 6 sand) 7.6.2 Cement mortar 1:6 (1 cement : 6 sand) 159 7.7 Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor two level. 7.7.1 Masonry work (first sort) in cement mortar 1:6 (1 cement : 6 sand) 7.7.2 Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 sand) 160 7.8 Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor two level for every floors or part thereof 161 7.9 Extra for coursed rubble masonry with hard stone (first or second sort) in : 7.9.1 Square or rectangular pillars 7.9.2 Circular pillars. 7.9.3 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. 162 7.10 Stone work in plain ashlar masonry in super structure upto floor two level in cement mortar 1:6 (1 cement : 6 sand) including pointing with cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the sand stone shade : 7.10.1 One face dressed. 7.10.1.1 Red sand stone 7.10.1.2 White sand stone 7.10.2 Both face dressed. 7.10.2.1 Red sand stone. 7.11.2.2 White sand stone 163 7.11 Stone work plain ashlar masonry in arches in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.11.1 One face dressed. 7.11.1.1 Red sand stone 7.11.1.2 White sand stone 7.11.2 Both face dressed. 7.11.2.1 Red sand stone. 7.11.2.2 White sand stone 164 7.12 Stone work plain ashlar masonry in domes, in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.12.1 One face dressed 7.12.1.1 Red sand stone 7.12.1.2 White sand stone 7.12.2 Both face dressed. 7.12.2.1 Red sand stone. 7.12.2.2 White sand stone. 165 7.13 Stone work ashlar masonry punched (ordinary) in superstructure above plinth level and upto floor two level in cement mortar 1:6 (1 white cement: 6 sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.13.1 Red sand stone one face punched. 7.13.2 Red sand stone both face punched 7.13.3 White sand stone one face punched. 7.13.4 White sand stone double face punched 166 7.14 Extra for stone work, plain ashlar or ashlar punched above floor two level for every floor or part thereof. 167 7.15 Extra for plain ashlar or ashlar punched in : 7.15.1 Square or rectangular pillars 168 7.16 Extra for stone work; plain ashlar or ashlar punched in curved on plan with a mean radius not exceeding 6 m. 169 7.17 Extra for additional cost of centering for arches exceeding 6m span including all strutting, bolting, wedging etc. And removal (area of soffit to be measured). 170 7.18 Stone work sunk or moulded or sunk and moulded upto floor Two level in cement mortar 1:6 (1cement : 6 sand) including pointing with white cement mortar 1:2 (1 white : 2 marble dust) with an admixture of pigment matching the stone shade : 7.18.1 Red sand stone 7.18.2 White sand stone 171 7.19 Extra for stone work sunk or moulded or sunk and moulded or carved in : 7.19.1 Triangular or Square or rectangular pillars 7.19.2 Circular or polygonal pillars 172 7.20 Extra for stone work sunk or moulded in cornices. 173 7.21 Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 meter height backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of clamps which shall be paid for separately): 7.21.1 Red sand stone - exposed face fine dressed with rough backing. 7.21.1.1 70 mm thick. 7.21.1.2 60 mm thick. 7.21.1.3 50 mm thick 7.21.1.4 40 mm thick. 7.21.1.5 30 mm thick. 7.21.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.2.1 70 mm thick. 7.21.2.2 60 mm thick. 7.21.2.3 50 mm thick 7.21.2.4 40 mm thick. 7.21.2.5 30 mm thick. 7.21.3 White sand stone - exposed face fine dressed with rough backing. 7.21.3.1 70 mm thick. 7.21.3.2 60 mm thick. 7.21.3.3 50 mm thick 7.21.3.4 40 mm thick. 7.21.3.5 30 mm thick. 7.21.4 White sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.4.1 70 mm thick. 7.21.4.2 60 mm thick. 7.21.4.3 50 mm thick 7.21.4.4 40 mm thick. 7.21.4.5 30 mm thick. 174 7.22 Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m. 175 7.23 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement :2 sand) including making the necessary chases in stone and holes in walls wherever required. 176 7.24 Providing and fixing stone dowels of size 10x5x2.5cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases 177 7.25 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases. 178 7.26 Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1 cement : 4 sand) including pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the stone shade: 7.26.1 Red sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 7.26.2 White sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 179 7.27 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade: 7.27.1 Red sand stone 7.27.2 White sand stone 180 7.28 30mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 sand) including finishing complete. 181 7.29 Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. 182 7.30 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.30.1 Red sand stone 7.30.2 White sand stone 183 7.31 Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1cement :3 sand) including pointing in white cement mortar 1:2 (1white cement: 2stone dust) with an admixture of pigment , matching the stone shade, jali slab without any chamfers etc. 7.31.1 Red sand stone 7.31.2 White sand stone 184 7.32 Extra for laying stone work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of stone work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 185 7.33 Extra for laying stone work in or under foul position. 186 7.34 Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 sand) i/c ruled pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in- charge. 187 7.35 Stone work ( machine cut edges) for wall lining upto 10 m height etc. (Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 sand) and jointed with Cement mortar 1:2 (1 cement : 2 marble dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately) 7.35.1 25mm thick Kota stone slabs exposed face dressed and rubbed. 7.35.2 25mm thick Dholpur stone slabs exposed face dressed and rubbed. 7.35.3 20 to 25mm thick kota stone slabs exposed slab not dressed and rubbed. 7.35.4 20 to 25mm thick Dholpur stone/shivpuri stone not dressed and rubbed. 188 7.36 Stone tile work with 8mm thick mirror polished and machine cut edge for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand), including pointing in white cement with an admixture of pigment to match the stone shade. 7.36.1 Granite stone of any colour and shade 7.36.2 Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble 189 7.37 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 190 7.38 Providing and fixing dry stone cladding upto 10 metre height with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and/ or with the help of cramps, pins etc. And sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins. shall be paid for separately.) 7.38.1 Red sand stone. 7.38.2 White sand stone 191 7.39 Providing and fixing structural steel frame (for dry stone cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/rectangular tube in the required pattern as per architectural drawing including including drilling necessary steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution).The frame work shall be fixed in true horizontal and vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) 192 7.40 Providing and fixing adjustable stainless steel clamps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame 193 8.1 Providing and supplying aluminium extruded tubular and other aluminium sections frame work as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coated of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 194 8.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.. (A) Structural analysis anddesign and preparation of shopdrawings for the specified designloads conforming to IS 875 partIII (the system must passed theproof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sectionsBfor fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals,microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage andprotection against fire hazard including (B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. toaccommodate 3 Dimentional movement for achieving perfect verticality and fixing structuralglazing system rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contactswith nuts and washers etc. of stainless steel grade 316, of the required capacity and in requirednumbers.(C) Providing and filling, two part pump filled, structural silicone sealant and one partweather silicone sealant compatible with the structural silicone sealant of required bitesize in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(D) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick andof sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight(E) Making provision for drainage of moisture/ water that enters the curtain glazing systemto make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary 195 8.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.8.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. 196 8.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 197 8.5 Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick having density 48 kg/m3, conforming to IS: 8183 and BS: 3958 Part 5.The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non- woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. 198 8.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., included in cost of relevent Item). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 199 8.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. 8.7.1 4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick) 8.7.2 4 mm thick alumminium composite pannel material consisting of 3.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 8.7.3 3 mm thick alumminium composite pannel material consisting of 2.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 200 8.8 Design, supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete.For the purpose of payment actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured., 201 8.9 Providing and fixing aluminium magnesium alloy (FACADE) wall cladding system consisting of panels 200mm wide x 17mm deep x 0.5mm thick of maximum length of 6.0 mtr. coil coated on a continuous paint line double baked and roll formed from centre to centre at a distance of maximum 1.20 mtr. The stringer shall be fixed to a suitable rigid structure. All panels shall be achromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and the other side (inner side) with a primer coat on a continuous paint line, and fixed as per the direction of the Engineer-in-Charge. 202 8.10 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line.Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. 203 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood 9.1.2 Sal wood 9.1.3 Kiln Head wood seasoned and chemically treated hard wood (Haldu, Kail, Bija wood.) 9.1.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 9.1.4.1 Frame of size 100mmX60mm single or double rebate 9.1.4.2 Frame of size 120mmX60mm double rebate. 205 9.2 Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001(Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately). 206 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) 9.3.1 Sal wood 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 207 9.4 Extra for additional labour wood work in circular shape, such as in frames of fan light : 9.4.1 Second class teak wood 9.4.2 Sal wood 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 208 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters 9.5.1.2 30 mm thick shutters 9.5.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.5.2.1 35 mm thick shutters 9.5.2.2 30 mm thick shutters 9.5.3 Kiln seasoned selected planks of sheesham wood. 9.5.3.1 35 mm thick shutters 9.5.3.2 30 mm thick shutters 9.5.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood shutters 9.5.4.1 35 mm thick 9.5.4.2 30 mm thick 209 9.6 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 9.6.1 Second class teak wood 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum 210 9.7 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in- charge and panelling with panels of: 9.7.1 12mm thick plain grade - 1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT - I IS : 3087 marked bonded with BWP type synthetic resin adhesive as per IS : 848 : 9.7.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre- lamination conforming to IS : 12823 Grade 1, Type - II marked: 9.7.3 12 mm thick one side pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelamination conforming to IS : 12823 Grade -1, Type II marked: 211 9.8 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.8.1 Second class teak wood 9.8.1.1 35 mm thick 9.8.1.2 30 mm thick 9.8.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.8.2.1 35 mm thick 9.8.2.2 30 mm thick 9.8.3 Kiln seasoned selected planks of sheesham wood. 9.8.3.1 35 mm thick 9.8.3.2 30 mm thick 9.8.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood 9. 8.4.1 30 mm thick shutters 9. 8.4.2 35 mm thick shutters 212 9.9 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked fixing with M.S. pressed butt hinges bright finished of required size with necessary screws as per directions of Engineer-in- charge. 30 mm thick shutters. 213 9.10 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 9.10.1 5 mm thick instead of 4 mm thick. 9.10.2 10 to 12 mm float glass 9.10.3 5.5 mm safety glass 9.10.4 10-12mm safety glass 214 9.11 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 215 9.12 Deduct for providing pin headed glass panes instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). 216 9.13 Extra for S.S, hinges providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). 217 9.14 Deduct for not providing hinges in doors, windows or clerestory window shutters with : 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. 218 9.15 Providing and fixing 25 mm thick Second class teak wood shutters using 4mm float glass for cup board etc. : 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. 9.15.2. 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 219 9.16 Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 9.16.1 12 mm thick 9.16.2 18 mm thick 220 9.17 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 9.17.1 18 mm thick 9.17.2 25 mm thick 221 9.18 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. 222 9.19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 223 9.20 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only. 224 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 225 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. 9.22.2 Circular. 226 9.23 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). 227 9.24 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 228 9.25 Providing and fixing wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.1.3 Kiln seasoned selected class of sheesham wood. 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.2.3 Kiln seasoned selected class of sheesham wood. 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.3.3 Kiln seasoned selected class of sheesham wood. 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.4.3 Kiln seasoned selected class of sheesham wood. 229 9.26 Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568 for doors, windows and clerestory windows including ISI marked M.S. pressed fixing with butt hinges bright finished of required size with necessary screws as per directions of Engineer-in-charge: 9.26.1 35 mm thick shutters 9.26.2 30 mm thick shutters 230 9.27 Providing 50x50x50mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 sand) and making good the walls etc. 231 9.28 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 9.28.1 25 mm long 9.28.2 32 mm long 9.28.3 40 mm long 9.28.4 50 mm long 9.28.5 60 mm long 232 9.29 Providing and fixing 2nd class teak wood plain lining tongued and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. 9.29.1 40 mm thick. 9.29.2 25 mm thick. 9.29.3 20 mm thick 9.29.4 12 mm thick 233 9.30 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre- laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 9.30.1 12 mm thick 9.30.2 18 mm thick 9.30.3 25 mm thick 234 9.31 Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 235 9.32 Providing and fixing plywood 4 mm thick one side decorative veneer conforming to IS: 1328 (type-1) for plain lining / cladding with necessary screws, priming coat on unexposed surface with: Decorative veneer facings of approved manufacture. 236 9.33 Providing and fixing 4mm thick coir veneer board, ISI marked IS: 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 237 9.34 Providing and fixing skirting of Pre- laminated with (one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : 9.34.1 18 mm thick 9.34.2 25 mm thick 238 9.35 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.35.1 2nd class teak wood 9.35.1.1 50x12 mm 9.35.1.2 50 x 20 mm 9.35.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.35.2.1 50x12 mm 9.35.2.2 50x20 mm 239 9.36 Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with : Second class teak wood. 240 9.37 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked,, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 241 9.38 Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842, including top cover of 6 mm coir veneer board, nickle plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 242 9.39 Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. 9.39.1 Non decorative veneer on both sides. 9.39.2 Particle board with decorative veneering on both sides. 243 9.40 Providing and fixing teak wood lipping of size 25x3 mm in pelmet. 244 9.41 Providing and fixing of 1.25 mm thick chromium plated brass plate, with two chromium plated curtain rods brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 9.41.1 12 mm dia. 9.41.2 20 mm dia. 9.41.3 25 mm dia. 245 9.42 Providing and fixing nickel plated curtain rods M.S. pipe with nickel plated brackets : 9.42.1 20 mm dia (heavy type) 9.42.2 25 mm dia (heavy type) 246 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.43.1 Fixed to steel windows by welding. 9.43.2 Fixed to openings /wooden frames with rawl plugs screws etc. 247 9.44 Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. 248 9.45 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 249 9.46 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. 9.46.1 With 2nd class teak wood beading 62x19 mm. 9.46.2 With 12 mm mild steel U beading. 250 9.47 Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. 251 9.48 Providing 40x5 mm flat (iron hold fast 40 cm long) (0.628 kg) including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) 252 9.49 Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : 9.49.1 Sal wood. 9.49.2 Haldu, Kail, Bija wood. 253 9.50 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 9.50.1 125x65x2.12 mm 9.50.2 100x58x1.90 mm 9.50.3 75x47x1.70 mm 9.50.4 50x37x1.50 mm 254 9.51 Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete : 9.51.1 125x90x4.00 mm 9.51.2 100x75x3.50 mm 9.51.3 75x60x3.10 mm 9.51.4 50x40x2.50 mm 255 9.52 Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 9.52.1 125x65x2.12 mm 9.52.2 100x58x1.90 mm 9.52.3 75x47x1.70 mm 9.52.4 50x37x1.50 mm 256 9.53 Providing and fixing ISI marked oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete : 9.53.1 150x125x27x2.80 mm 9.53.2 125x125x27x2.80 mm 9.53.3 100x125x27x2.80 mm 9.53.4 75x100x20x2.24 mm 257 9.54 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 9.54.1 150 mm 9.54.2 125 mm 9.54.3 100 mm 258 9.55 Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 9.55.1 150 mm 9.55.2 125 mm 9.55.3 100 mm 259 9.56 Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete. 9.56.1 Overall width 35 mm. 9.56.2 Overall width 50 mm. 9.56.3 Overall width 65 mm. 260 9.57 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.57.1 300x16 mm 9.57.2 250x16 mm 261 9.58 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.58.1 250x10 mm 9.58.2 200x10 mm 9.58.3 150x10 mm 9.58.4 100x10 mm 262 9.59 Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete 263 9.60 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.60.1 300x20x6 mm 9.60.2 250x20x6 mm 264 9.61 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.61.1 125 mm 9.61.2 100 mm 9.61.3 75 mm 265 9.62 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 9.62.1 150 mm 9.62.2 115 mm 9.62.3 90 mm 266 9.63 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 9.63.1 300 mm weighing not less than 200 gms. 9.63.2 250 mm weighing not less than 150 gms. 9.63.3 200 mm weighing not less than 120 gms. 267 9.64 Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) 268 9.65 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 9.65.1 300x16 mm 9.65.2 250x16 mm 269 9.66 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.66.1 250x10 mm 9.66.2 200x10 mm 9.66.3 150x10 mm 9.66.4 100x10 mm 270 9.67 Providing and fixing ISI marked 85x42mm stainless steel pull bolt lock with necessary screws bolts, nut and washers etc. complete. 271 9.68 Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 9.68.1 300x20x6 mm 9.68.2 250x20x6 mm 272 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 9.69.1 125 mm 9.69.2 100 mm 9.69.3 75 mm 273 9.70 Providing and fixing stainless steel hasp and staple (safety type) conforming to IS specification with necessary screws etc. complete : 9.70.1 150 mm 9.70.2 115 mm 9.70.3 90 mm 274 9.71 Providing and fixing stainless steel casement stays (straight peg type) conforming to IS specification with necessary screws etc. complete. 9.71.1 300 mm weighing not less than 200 gms. 9.71.2 250 mm weighing not less than 150 gms. 9.71.3 200 mm weighing not less than 120 gms. 275 9.72 Providing and fixing stainless steel safety chain with necessary fixtures for doors. Conforming to IS specification (Weighing not less than 450 gms.) 276 9.73 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.73.1 125x64x1.90 mm 9.73.2 100X58X1.90 mm 9.73.3 75x47x1.80 mm 9.73.4 50x37x1.50 mm 277 9.74 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.74.1 125x64x2.50 mm 9.74.2 100x60x2.50 mm 9.74.3 75x50x2.50 mm 278 9.75 Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) 279 9.76 Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. 280 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) 9.77.2 125x70x4 mm (ordinary type) 9.77.3 100x85x5.5 mm (heavy type) 9.77.4 100x70x4 mm (ordinary type) 9.77.5 75x65x4 mm (heavy type) 9.77.6 75x40x2.5 mm (ordinary type) 9.77.7 50x40x2.5 mm (ordinary type) 281 9.78 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.78.1 150x125x27x5 mm 9.78.2 125x125x27x5 mm 9.78.3 100x125x27x5 mm 9.78.4 75x100x20x3.2 mm 282 9.79 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.79.1 400x10 mm 9.79.2 250x10 mm 9.79.3 200x10 mm 9.79.4 150x10 mm 9.79.5 100x10 mm 283 9.80 Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.80.1 300x16x5 mm 9.80.2 250x16x5 mm 284 9.81 Providing and fixing bright finished brass handles with necessary screws etc. complete. 9.81.1 125 mm 9.81.2 100 mm 9.81.3 75 mm 285 9.82 Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 300x16mm 9.82.2 250x16mm 286 9.83 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 287 9.84 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). 288 9.85 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 289 9.86 Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality). 290 9.87 Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 9.87.1 40 mm 9.87.2 50 mm 9.87.3 65 mm 9.87.4 75 mm 291 9.88 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) 292 9.89 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 293 9.90 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. 294 9.91 Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 9.91.1 300 mm weighing not less than 330 gms 9.91.2 250 mm weighing not less than 280 gms 9.91.3 200 mm weighing not less than 240 gms 295 9.92 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: 9.92.1 150 mm 9.92.2 115 mm 9.92.3 90 mm 296 9.93 Providing and fixing Cromium plated brass hanging type floor door stopper with necessary screws, etc. complete. 297 9.94 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. 298 9.95 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. 299 9.96 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 300 9.97 Providing and fixing chromium plated brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 301 9.98 Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). 302 9.99 Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : 9.99.1 Size 40 mm 9.99.2 Size 50 mm 9.99.3 Size 65 mm 9.99.4 Size 75 mm 303 9.100 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. 304 9.101 Providing and fixing chromium plated brass sliding door bolts ISI marked with nuts and screws etc complete. 9.101.1 300x16mm 9.101.2 250x16mm 305 9.102 Providing and fixing chromium plated brass tower bolts ISI marked with nuts and screws etc complete. 9.102.1 400X10mm 9.102.2 300x10mm 9.102.3 250x10mm 9.102.4 200x10 mm 9.102.5 150x10 mm 9.102.6 100x10 mm 306 9.103 Providing and fixing chromium plated brass door latch ISI marked with necessary screws etc complete. 9.103.1 300x16x5mm 9.103.2 250x16x5mm 307 9.104 Providing and fixing chromium plated brass night latch ISI marked with necessary screws etc complete. 308 9.105 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 9.105.1 125 mm 9.105.2 100 mm 9.105.3 75 mm 309 9.106 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. 310 9.107 Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 9.107.1 300 mm weighing not less than 330 gms 9.107.2 250 mm weighing not less than 280 gms 9.107.3 200 mm weighing not less than 240 gms 311 9.108 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note:- Aluminum hinges shall not be used in wooden shutters. 9.108.1 125x75x4 mm 9.108.2 125x63x4 mm 9.108.3 100x75x4 mm 9.108.4 100x63x4 mm 9.108.5 100x63x3.2 mm 9.108.6 75x63x4 mm 9.108.7 75x63x3.2 mm 9.108.8 75x45x3.2 mm 312 9.109 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.1 300x16 mm 9.109.2 250x16 mm 313 9.110 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.1 400X10mm 9.110.2 300x10 mm 9.110.3 250x10 mm 9.110.4 200x10 mm 9.110.5 150x10 mm 9.110.6 100x10 mm 314 9.111 Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete. 315 9.112 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 316 9.113 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 125 mm 9.113.2 100 mm 9.113.3 75 mm 317 9.114 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.114.1 Single rubber stopper 9.114.2 Twin rubber stopper 318 9.115 Providing and fixing aluminium casement window stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 319 9.116 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 9.117 Providing and fixing aluminum U beading of required size to Pre-laminated /flush door shutter including fixing etc. complete as per direction of Engineer-in-charge. 321 9.118 Providing and fixing PTMT handles with necessary screws etc. complete. 9.118.1 125x34x24 mm weighing not less than 23 gms. 9.118.2 150x34x24 mm weighing not less than 26 gms. 322 9.119 Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.119.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms. 9.119.2 100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms. 323 9.120 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. 9.120.1 152x42x18 mm weighing not less than 60 gms. 9.120.2 202x42x18 mm weighing not less than 78 gms. 324 9.121 Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. 325 9.122 Providing and fixing PTMT hanging type floor door stoper with necessary screws etc complete. 326 9.123 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 9.123.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.1.1 Second class teak wood. 9.123.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.1.3 Kiln seasoned selected class of sheesham wood. 9.123.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.2.1 Second class teak wood. 9.123.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.2.3 Kiln seasoned selected class of sheesham wood. 9.123.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.3.1 Second class teak wood. 9.123.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.3.3 Kiln seasoned selected class of sheesham wood. 9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.4.1 Second class teak wood. 9.123.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.4.3 Kiln seasoned selected class of sheesham wood. 327 9.124 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 9.124.1 With 2nd class teak wood beading 62x19 mm. 9.124.2 With 12 mm mild steel U beading. 328 9.125 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 329 9.126 Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm (base and height). 330 9.127 Providing and fixing 2nd class teak wood lipping/ moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer- in-charge. 331 9.128 Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 332 9.129 Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality). 9.129.1 Triple strip vertical type. 9.129.2 Double strip (horizontal type). 333 9.130 Providing and fixing magic eye in door shutters including fixing. Complete (Best make of approved quality). 334 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long 9.131.2 450mm long 9.131.3 500mm long 335 9.132 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) 336 9.133 Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. 9.133.1 Marine plywood conforming to IS: 710 9.133.2 Fire retardant plywood conforming to IS: 5509. 337 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.1 1.5 mm thick. 9.134.2 1.0 mm thick. 338 9.135 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge. 339 9.136 Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. 9.136.1 With decorative veneering on one side and commercial veneering on other side. 9.136.2 With non decorative veneering on both sides. 340 9.137 Providing and fixing factory made shutters of 25 mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium U type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of U beading and hinges will be paid for separately). 341 9.138 Providing and fixing in wall lining MDF board medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 9.138.1 12 mm thick. 9.138.2 18 mm thick. 9.138.3 25 mm thick. 342 9.139 Providing and fixing 25mm thick pre- laminated medium density fibre board exterior grade(Grade-I) IS:14587:1998 marked one side decorative to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinges IS:3818 marked with necessary screwed complete 343 9.140 Providing and fixing skirting with Pre- laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand complete. 9.140.1 18 mm thick 9.140.2 25 mm thick 344 9.141 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete. 9.141.1 75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced gypsum (GRG) plaster board conforming to IS: 2095: part 3 1996 Board with BIS certification marks. 9.141.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS:2095: part I 1996 Board with BIS certification marks. 9.141.3 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./sq.cm. 9.141.4 66mm overall thickness partition using 8mm thick double skin non- asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. 9.141.5 68mm overall thickness partition using 9mm thick Heavy Duty Fibre Cement Board double skin non asbestos, reinforced with cellulose fibre,manufactured through autoclaving proces(High presssure steam cured)Type A, Category 4 conforming to IS 14862:2000. (for wet areas) 9.141.6 70 mm overall thickness Partition using 10mm thick double skin non-asbestost multipurpose termite, fire & moisure resistance (acoustic 30db) cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 345 9.142 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the W profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55 mm, placed @ 610mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing and directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 9.142.1 10 mm thick tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure, with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. 9.142.2 12 mm thick Gypsum board conforming to IS: 2095 Part-I. 9.142.3 8 mm thick non-asbestost multipurpose termite, fire & moisure resistance cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 9.142.4 8mm Both side Factory Prelamianted cement bonded particle board as per IS: 15786. 9.142.5 9mm thick non asbestos,heavy duty fibre cement board reinforced with cellulose fibre manufactured through autoclaving process(High pressure steam cured) Type A,Category 4, conforming to IS 14862. 346 9.143 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically and horizontally ) including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer- in-charge. 347 9.144 Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 348 9.145 Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). 9.145.1 Board 12 mm thick 9.145.2 Board 18 mm thick 349 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick 9.146.2 25 mm thick 350 9.147 Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing, of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward. Then panels shall positioned and pressed into place. 351 9.148 Providing and installation of acoustical wall panelling wood finish Slats made out of HDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts bothways. 352 9.149 Providing and installation of paintble acoustic wall panelling consisting of strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8- 20kg/m2 which is fixed to GI strut system. fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit. 9.149.1 Wt. 8.20 kg/m2 9.149.2 Wt. 4.2 kg/m2 353 9.150 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-incharge. (Frame work shall be paid forseparately) 9.150.1 12mm thick commercial ply conforming to IS: 1328 BWR type. 9.150.2 18mm thick commercial ply conforming to IS: 1328 BWR type. 354 9.151 Providing and Installation of acoustic wall panelling consisting of Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x2400x20mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI strut system. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers. Kerfed edge Fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. 355 9.152 Providing and Installation of acoustic wall panelling consisting of Soak Cord of selected colours as approved by Engineer in charge, square edge Fabric wrapped wood fiber panels of size 600x1200x10mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI struts,Z bars. GI Z bars having 40mm height, thickness 1.2mm is first fixed behind the panels by identifying resin spots by using suitable fasteners.Clean exposed surfaces of wall and ensure walls are in plumb line before installing on wall (provide necessary packing shims if required). Soak cord square edge panels shall be slided into the Z bars fixed on wall. 356 9.153 Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 300mm centers. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. 357 9.154 Providing and Installation of wall panelling consisting of Square edge Magnesia core panels of size 1100x2400x8mmmm having density 1000kgs/m3, weight 8kg/m2 installed by using GI Strut system. The GI struct system includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges of 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. The panels to be fixed on the cross channel with suitable fasteners. 358 9.155 Supplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling with suitable fasteners at 300mm centers staggered. Second layer of magenesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical charecterstics. 9.155.1 Using 8mm thick magnesia block 9.155.2 Using10mm thick magnesia block 9.155.3 Using12mm thick magnesia block 9.155.4 Using12mm thick magnesia block 359 9.156 Add extra for providing and fixing Thermal insulation by providing 50mm thick synth PF having dencity 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall. 360 9.157 Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor II level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2. 361 9.158 Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: 9.158.1 Extruded section Profile size 48x40 mm. 9.158.2 Extruded section Profile size 42x50 mm. 362 9.159 Providing and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 363 9.160 Providing and fixing UPVC panelled door shutter UPVC 30 mm thick factory made PVC or UPVC door shutter made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. 364 9.161 Providing and fixing 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm (± 0.3mm). PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. The Top and Bottom edges of the shutter are covered with an end-cap of the size 25mmx11mm. Door shutter shall be reinforced with special polymeric reinforcements as per required specification and direction of Engineer-in- charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. 365 9.162 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100mmx37mm with wall thickness 2mm (±0.2mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos. of plastic brackets of size 100mmx37mm, wall thickness 2mm (+0.2mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100mmx20 mm, and inserting 2 nos. tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-charge. 366 9.163 Providing and Fixing, factory made, PVC door frame made of PVC extruded sections of size 75mmx53 mm, having wall thickness 2.0mm (±0.2mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x2mm thickness (± 0.2 mm) and 75mmx200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos. and sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineer-in-charge. 367 9.164 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115mm x 37mm with wall thickness , panels of 100 x 20 mm printed and laminated and inserting 2 nos. 6 mm dia. bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-Charge. 368 9.165 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers specification and direction of Engineer-in- Charge. 369 9.166 Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. 9.166.1 Plain PVC door shutters. 9.166.2 Pre laminated PVC door shutters. 370 9.167 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. 371 9.168 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles, top and bottom rails shall have one side wall thickness of 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. 9.168.2 Decorative finish (both side wood grained finish). 372 9.169 Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) 9.169.1 Single rebate (75 mm X 50 mm) 9.169.2 Single rebate (100 mm X50 mm) 9.169.3 Single or double rebate (125 mm X 65 mm) 373 9.170 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter 374 9.171 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 9.171.1 30 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 9.171.2 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 375 9.172 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 9.172.1 18 mm thick 9.172.2 25 mm thick 376 9.173 Providing and fixing factory made single extruded WPC (Wood polymer composite solid plain white color board for backing of cupboards and bathrooms/ kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-in-Charge. (Note: stainless steel screws shall be paid separately) 9.173.1 6 mm thick 9.173.2 12 mm thick 377 9.174 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 378 9.175 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5 mm (±0.2 mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2nos of PVC bracket of size 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge. 379 9.176 35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded soild PVC profiles, 5mm (±0.2mm) thick, having styles and rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm solid core in middle of rail section integrally extruded, fixing the styles and rails with the help of solvent and self driven self tapping screws of 125 mm x11 mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturers specification and direction of Engineer-in- charge. 9.176.1 Non decorative finish (matt finish). 9.176.2 Decorative finish (wood grained finish). 380 9.177 Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. 381 9.178 Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat .Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stat shall be provided 382 9.179 Providing and fixing to existing door frames. 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. 383 9.180 Providing and fixing door frame FRP 30mm thick fiberglass reinforced Plastic (F.R.P.) flush door shutter in different plain and wood inish made with fire retardant grade unsaturated polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 384 9.181 Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight. 385 9.182 Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in- charge (Dash fastener to be paid for separately). 386 9.183 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). 387 9.184 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc. complete all as per direction of Engineer- in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance. 388 9.185 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 389 9.186 Providing and Fixing factory made UPVC door frame made of UPVC exturded sections, of size 65 mmx55 mm with wall thickness 2.0 mm (±0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mmx30 mm having wall thickness 2 mm (±0.2mm), including providing and fixing 3 nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number and size of anchor dash fastners, all complete as per manufacturers specification and direction of Engineer-in-charge. 390 9.187 Providing and Fixing, UPVC factory made, white colour casement/sliding window and door made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8 mmx100 mm long fasteners, all complete as per direction of Engineer-in-charge. (Glazing, hardware hinges and fitting etc. to be paid separately.) 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) 9.187.1.5 Glazing bead (12mm x 18mm) 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) 9.187.2.3 Casement Glazing bead (35mm x 18 mm) 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) 9.187.3.2 Sliding window Sash (60mm x 44mm) 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) 9.187.4.2 Sliding Door Sash (80mm x 44mm) 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) 391 9.188 Providing and fixing stainless steel (SS- 304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality with necessary stainless steel screws etc. as per direction of Engineer-in-charge. 9.188.1 200 x 19 x 1.9 mm 9.188.2 250 x 19 x 1.9 mm 9.188.3 300 x 19 x 1.9 mm 9.188.4 350 x 19 x 1.9 mm 9.188.5 400 x 19 x 1.9 mm 392 9.189 Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. 393 9.190 Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete. 394 9.191 Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete. 395 9.192 Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete. 396 9.193 Providing and fixing steel (white powder coated) crescent lock for UPVC sliding window/ door with necessary screws etc. complete. 397 9.194 Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion 67 x 80 all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) 398 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic capsof approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) 399 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). 400 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 401 9.198 Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). 402 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madAfter fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: - For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 10.00 sqm). 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto10.00 sqm). 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 403 9.200 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive. An additional 5mm thick Prelaminated PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-in- charge. Manufacturer’s specification and drawing. 30 mm thick pre laminated PVC door shutters. 404 9.201 Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 -2000 certified company. 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter 405 9.202 Providing and fixing factory made pre laminated solid PVC flush door shutters 28 to 30 mm thick made from co-extruded three layer rigid PVC foam sheet with density not less than 600 kg/cum, conforming to IS: 2380 part 14, for screw holding strength and outer layers laminated on both sides by laminated sheet with density not less than 1400 kg/cum, lamination shall be at the manufacturing process itself and manufactured by an ISO: 9001-2000 certified company. 9.202.1 1mm thick laminated sheet 9.202.2 0.12 mm thick laminated sheet 406 9.203 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens with well matched 3mm thick commercial 3ply veneering consisting of vertical grains, cross bands withing frame of door/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 9.203.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.2 35mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.3 25mm thick (for cupboard) including 3 nos. 75mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 407 9.204 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) non decorative type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed cross bands including all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50cm. Each shutter shall be factory made to the exact opening size within frame of doors/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and confirmity with IS:2202. 9.204.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary. 9.204.2 30mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.204.3 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 408 9.205 Deduct for not providing 2nd class teak wood batten lipping in factory made shutters i.e. item no 9.203 and 9.204. 409 9.206 Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. 9.206.1 Acrylic Solid Surface sheet – Glacier white designer white 9.206.1.1 6 mm thick sheet 9.206.1.2 12 mm thick sheet 9.206.2 Acrylic Solid Surface sheet - Any Solid colours/Hospital use Medi Blue 9.206.2.1 6 mm thick sheet 9.206.2.2 12 mm thick sheet 9.206.3 Acrylic Solid Surface sheet - Any other 9.206.3.1 6 mm thick sheet 9.206.3.2 12 mm thick sheet 410 9.207 Providing and fixing of 8 mm thick non asbestos multipurpose board reinforced with cellulose fibers for wall cladding will consist of following operations:1. Fixing of a layer of 6mm Moisture/fire Resistance Heavy Duty fibre cement Boards over above mentioned 6 mm heavy duty fibre cement board with the help of 25mm self drilling, self tapping Fibre Cement screws @ 300mm c/c. All external corners are to be protected with the use of suitable corner profile of GI or PVC. All above operation is to be done in order and as directed by Engineer-in-Charge.(frame work to be paid separately). 411 9.208 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS: 15380(2003), eco-friendly, termite resistant, borer free, anti warping phenol formaldehyde (PF), decorative designe moulded or rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company’ gujcon, century, green shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.208.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 412 9.209 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), non decorative designe moulded and labor complete as per specifications and direction of engineer-in- charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.209.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.209.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws 9.209.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 413 9.210 Providing and fixing IS marked factory made High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), 2 and 4 Panel designe moulded or plain construction with particle board shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.210.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.210.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 414 9.211 HDF decorative prelaminated pine wood panel door with glass / wiremash:- Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.211.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.211.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 415 9.212 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), . The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.212.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.2 32 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. Piano hinges with screws. 416 9.213 Non Decorative Pine Wood Flush Door:- Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer- in-charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202 9.213.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 417 9.214 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned sheet shall be as per IS: 2046 type S of approved quality. Each shutter shall be factory made to the exact size (opening) within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in- charge. 9.214.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 418 9.215 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in-charge. 9.215.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.3 25mm thick (for cupboard) including 3 nos. 75 mm long ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 419 9.216 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) veneer decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) s and commercial grade face veneers on both outer faces of shutters including kiln seasoned and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. 9.216.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 420 9.217 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides,made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastne with necesary stainless steel screws, all complete as per direction of Engineer-in-charge. 421 9.218 Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity.Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. 422 10.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 423 10.2 Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 424 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. 425 10.4 Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S.gusset plates at the junction and corners 25mm dia pulley,40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. 426 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6mm for diagonal braces 10.5.2 Using flats 30x6mm for diagonal braces and central cross piece. 427 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. 10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover. 10.6.3 80x0.90 mm M.S. laths with 0.90 mm thick top cover. 428 10.7 Extra for providing suitable mechanical device chain and crank operation for operating rolling shutters. 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 10.7.2 Exceeding 16.80 sqm in area. 429 10.8 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured). 430 10.9 Providing and fixing ball bearing for rolling shutters. 431 10.10 Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). 10.10.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.10.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.10.3 Extra for providing and fixing steel beading of size 10x10x1.6mm (box type) approved shape and section with screws instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units. 432 10.11 Providing and fixing L-iron or T-iron frames for doors, windows and ventilators of mild steel L-section or T-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.11.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 433 10.12 Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 434 10.13 Providing and fixing M.S. Tubular frames and shutters or frames only or shutters only for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws and applying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.13.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 435 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes 10.14.2 Hot finished seamless type tubes 10.14.3 Electric resistance or induction butt welded tubes. 436 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats of Epoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. 437 10.16 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. 438 10.17 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. 439 10.18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 440 10.19 Providing and fixing bolts including nuts and washers complete. 441 10.20 Providing and fixing M.S. rivets of sizes in position. 442 10.21 Welding by gas or electric plant including transportation of plant at site etc. complete. 443 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 444 10.23 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer. 10.23.1 M.S. tube. 10.23.2 E.R.W. tubes. 445 10.24 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. 10.24.1 10x60 mm 10.24.2 10x80 mm 10.24.3 10x120 mm 10.24.4 10x140 mm 10.24.5 10x160mm 446 10.25 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 447 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 448 10.27 Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. 10.27.1 With 4.0 mm thick glass panes 10.27.2 With 5.50 mm thick glass panes 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm box beading. 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 449 10.28 Add extra for providing and fixing froasted glass instead of float glass. 10.28.1 With 4.0 mm thick glass panes. 10.28.2 With 5.5 mm thick glass panes. 450 10.29 Supplying at site: 10.29.1 R.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge including fixing (cost of earth works in excavation, concrete works in foundation to be paid separately). 10.29.2 Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (cost of earth work in excavation and concrete work in foundation to be paid separately) 10.29.3 Supplying at site -Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming painting to be paid for separately). 451 10.30 Supplying and fixing turn buckles and straining bolts for barbed wire fencing. (Labour rate only). 452 10.31 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) with GI barbed wire. 453 10.32 Fencing with barbed G.I. wire angle iron post placed fitted to at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. 454 10.33 Fixing Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, painting, earth work in excavation and cement concrete to be paid for separately). (Labour rate only). 455 10.34 Providing and fixing G.I. or PVC coated G.I.wire chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in-charge. (Cost of post, painting earthwork & c.c. to be paid separately) 10.34.1 Made of G.I. wire. 10.34.2 Made of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required colour and shade. 456 10.35 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer-in- Charge. (cost of post painting earth work & C.C. to be paid separately) 457 10.36 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). 458 10.37 Providing and fixing of ISI marked insulated fire rated GI Sheet doors conforming to FD 120-PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The Door frame shall be single rebate grooved profile of size minimum 125 mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note:- For grouting of Steel frames in masonary installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm thick galvanised steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall befactory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 89x3 mm along with all suitable hardware (Payable in extra item).Vision lite size 185x285 (max area up to 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width al around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer 459 10.38 Providing and fixing of factory make air tight casement windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 10.38.1 Openable window 10.38.2 Fixed windows 460 10.39 Providing and fixing of factory make single rebate openable/fixed windows made of roll formed galvanized pre- pained steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick) heavy duty pivot hinges per shutter and window fitted without glazing including 10mm square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. 10.39.1 Openable single rebate window 10.39.2 Fixed single rebate window 461 10.40 Providing and fixing of factory make double rebate windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self- expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete.. 10.40.1 Openable double rebate window 10.40.2 Fixed double rebate window 462 10.41 Providing and fixing of factory make fixed louvers fabricated from roll formed sections made of galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/powder coated Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. (glazing shall be paid separately as per SOR rate) 463 10.42 Providing and fixing of factory make pre painted steel sliding window 2 track-2 panel sliding window fabricated from roll formed sections made of galvanized steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 464 10.43 Providing and fixing pre painted steel sliding window 3 fabricated from Roll formed sections made of galvanized Steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 465 11.1 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) 20mm nominal size stone aggregate in panels finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(Area of panel not to exceed 2.0 sqm) 466 11.2 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 467 11.3 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 468 11.4 Cement plaster skirting 18 mm thick (upto 30 cm height) with cement mortar 1:3 (1 cement: 3 sand) finished with a floating coat of neat cement. 469 11.5 Cement concrete pavement with Cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete. 470 11.6 Making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. 471 11.7 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1mm to 4mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.7.1 Dark shade pigment with ordinary cement. 11.7.2 Light shade pigment with white cement. 11.7.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.7.4 White cement without any pigment. 11.7.5 Light shade pigment with ordinary cement. 11.7.6 Ordinary cement without any pigment. 472 11.8 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 9mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4mm to 7mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder : 7 marble chips) by volume including cement slurry etc. complete. (Area of panel not to exceed 2.0 sqm) 11.8.1 Dark shade pigment with Ordinary cement. 11.8.2 Light shade pigment with white cement. 11.8.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.8.4 White cement without any pigment. 11.8.5 Light shade pigment with ordinary cement. 11.8.6 Ordinary cement without any pigment. 473 11.9 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7mm to 10mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.9.1 Dark shade pigment with ordinary cement. 11.9.2 Light shade pigment with white cement. 11.9.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.9.4 White cement without any pigment. 11.9.5 Light shade pigment with ordinary cement. 11.9.6 Ordinary cement without any pigment. 474 11.10 Marble chips skirting (upto 30 cm height) 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 sand) : rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :7 marble chips) by volume : 11.10.1 Dark shade pigment with ordinary cement. 11.10.2 Light shade pigment with white cement. 11.10.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.10.4 White cement without any pigment. 11.10.5 Light shade pigment with ordinary cement. 11.10.6 Ordinary cement without any pigment. 475 11.11 Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width including cost of forming, nosing etc. 476 11.12 Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. 477 11.13 18 mm thick crazy marble stone white, black or as specified marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc.complete . 478 11.14 Precast terrazo tiles 22mm thick with graded marble chips of size upto12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.14.1 Light shade using white cement. 11.14.2 Medium shade using 50%white cement and 50% ordinary cement. 11.14.3 Dark shade using ordinary cement. 11.14.4 Ordinary cement without any pigment. 479 11.15 Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width. 480 11.16 Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : 11.16.1 Light shade pigment using white cement. 11.16.2 Medium shades pigment using 50% white cement and 50% ordinary cement. 11.16.3 Dark shade pigment using ordinary cement. 11.16.4 Ordinary cement without any pigment. 481 11.17 Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.17.1 Light shade pigment using white cement. 11.17.2 Medium shade pigment using 50% white cement, 50% ordinary cement. 11.17.3 Dark shade pigment using ordinary cement. 11.17.4 Ordinary cement without any pigment. 482 11.18 Chequered precast cement concrete tiles any finish, any size 22 mm thick IS:13810-1993 ISI mark in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles, 15mm thick screed bad in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 11.18.1 Light shade pigment using white cement. 11.18.2 Medium shade pigment using 50% white cement 50% Grey cement. 11.18.3 Dark shade pigment using ordinary cement. 11.18.4 Ordinary cement without any pigment. 483 11.19 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sandand grey cement slurry, joints treated with white cement mixed with pigment to match colour of stone including rubbing and polishing complete with : (area of slabs over 0.5 sqm) 11.19.1 Makrana white second quality. 11.19.2 Raj Nagar plain. 11.19.3 Agaria White/Morgarh 11.19.4 Katni marble 11.19.5 Black Zebra. 11.19.6 Udaipur / Baroda green marble 11.19.7 Pink plain marble. 11.19.8 Jaisalmer Yellow 484 11.20 Marble stone 18 mm thick in riser of step, skirting, dado and pillar laid on 12 mm average thick cement mortar 1:3 (1 cement: 3 sand and laid with white cement slurry) joints treated with white cement mixed with pigment to match the shade of the slab i/c rubbing and polishing complete. (area of slab over0.50sqm.) 11.20.1 Makrana white second quality. 11.20.2 Raj Nagar plain. 11.20.3 Agaria White/Morgarh 11.20.4 Katni marble 11.20.5 Black Zebra. 11.20.6 Udaipur / Baroda green marble 11.20.7 Pink plain marble. 11.20.8 Jaisalmer Yellow 485 11.21 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slabs over 0.50 sqm.) 11.21.1 Makrana white second quality. 11.21.2 Raj Nagar plain. 11.21.3 Agaria White/Morgarh 11.21.4 Katni marble 11.21.5 Black Zebra. 11.21.6 Udaipur / Baroda green marble 11.21.7 Pink plain marble. 11.21.8 Jaisalmer Yellow 486 11.22 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black 11.22.2.1 Granite fine grained dark crystal of other colours and various patterns 11.22.2.2 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns 11.22.2.3 Granite grey/pink/brown with various patterns 11.22.3 Cuddpah stone 487 11.23 Extra for prefinished nosing to treads of steps of marble stone. 488 11.24 Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre. 489 11.25 Extra for prefinished grooves to treads of steps of granite stone 490 11.26 Providing and laying machine cut, mirror polished, Italian Marble stone (18 mm thick Italian Marble stone slab, Perlato, Rosso erona, Fire Red or Dark Emperadore etc.)work in flooring laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 491 11.27 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. for wall lining (veneer work) including dado, skirting, risers of steps etc. thick cement mortar 1:3 (1 cement : 3 sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 492 11.28 Italian marble flooring in required design and patterns 11.28.1 Providing and laying machine cut, mirror polished Italian Marble stone 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadoreetc flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Note – This item shall be executed only after the prior approval of Chief Engineer. 493 11.29 Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). 111.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns 494 11.30 Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns 11.90.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns 492 11.31 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement: 4 sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. (area of slab more than 0.50 sqm) 11.31.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.3 Gray/Pink/Brown or equivalent with various patterns 495 11.32 Deduct for not polishing granite flooring (item no 11.29 & 11.30) 496 11.33 Providing and laying Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing and as directed by the Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent, 11.33.1 Flamed Finish Polish 11.33.2 Leather Finish Polish 497 11.34 Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. 498 11.35 Providing and fixing 10x10x7.50 cm Granite stone block hand cut andchisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 sand) with joints 10mm wide filled with same mortar mixed with matching pigment including ruled pointing etc. complete as per direction of engineer-in charge. 499 11.36 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) 500 11.37 Deduction for using 20 mm thick slab instead of 25 mm thick slab of kota stone in item no 11.35 501 11.38 Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 502 11.38.1 10-12 mm thick 11.38.2 20 mm thick 503 11.39 Kota stone slab (area less than 0.5 sqm) rough chiseled dressed average 40 mm thick flooring for parking and open area of thickness over 20 mm (average) thick base laid over and jointed with grey cement slurry complete with base of cement mortar 1:4 (1 Cement : 4 Sand) 504 11.40 Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 11.40.1 Marble work 11.40.2 Granite work. 505 11.41 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 506 11.42 Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 507 11.43 Mirror polishing on marble work/Granite work/stone work wherever required to give high gloss finish complete. 508 11.44 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1cement : 5 sand) with joints finished flush. 11.44.1 Red sand stone 11.44.2 White sand stone 11.44.3 Grey lime stone 11.44.4 Kota stone 509 11.45 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. 11.45.1 Red sand stone 11.45.2 White sand stone 510 11.46 40 mm thick machine rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 sand) mixed with pigment to match the shade of stone and pointing with same mortar 11.46.1 Red sand stone 11.46.2 White sand stone 511 11.47 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 512 11.48 Extra for Kota stone/ sand stone in treads of steps and risers using single length upto 1.05 metre. 513 11.49 Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 514 11.50 Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. 515 11.51 Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. 516 11.52 Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete. 517 11.53 Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. 518 11.54 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. 519 11.55 Deduct for not using 20mm thick cement mortar 1:4 (1 cement: 4 sand) bedding in laying of floor tiles. 520 11.56 Fixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 521 11.57 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 522 11.58 Providing and fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 523 11.59 Providing and laying 500x500x40mm thick Turf paver on 150mm thick sub grade of compacted bed of 20mm nominal size stone aggregate and base course with 50mm thick sand and filling joints with sand including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer- in-charge. 524 11.60 Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge. 525 11.60.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile. 526 11.60.2 In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 sand).Acid and alkali resistant tile. 527 11.61 8 mm thick.stones Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 11.61.1 Marble tiles (polished) Raj Nagar. 11.61.2 Granite tile of any colour /shade 528 11.62 Providing and fixing cramps of required size and shape in RCC/ CC /Stone/ Brick masonry backing with cement mortar 1:2 ( 1 cement :2 sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 11.62.1 Gunmetal cramps. 11.62.2 Stainless steel cramps. 529 11.63 Providing and fixing expansion hold fasteners of wedge expansion type on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 11.63.1 Fastener with threaded dia 6 mm. 11.63.2 Fastener with threaded dia 10 mm. 11.63.3 Fastener with threaded dia 12 mm. 530 11.64 Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. 11.64.1 White Agaria Marble Stone. 11.64.2 Granite Stone of approved shade. 531 11.65 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer- in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 11.65.1 300 mm Finished Floor Height (FFH) 11.65.2 450 mm Finished Floor Height (FFH). 532 11.66 Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. 533 11.67 Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period (This item is to be used only for operation theaters in hospitals) 11.67.1 1 mm thick 11.67.2 2 mm thick 11.67.3 3 mm thick 534 11.68 Providing and fixing acoustic PVC (Poly Vinyl Flooring) EN (European Standard) over fiberglass mat PVC foam backing (EN 14904), total thickness is 3.25mm (EN 428/EN 427), wear layer is 0.85 mm thick (EN 429), anti-bacterial and anti-fungus surface treatment , chemical resistance test qualified (EN-423)-high resistance, thermal and underfloor heating test qualified (EN12524) - all vinyl sheets must be linked crosswise with a continuous copper strip and finally connected to earth for grounding electrostatic electrical charges. Suitable and slip resistant. Recommended to use in area like Lecturer room, Conference room, Kids area, School, colleges, Residential and all commercial official scope etc. 535 11.69 Providing and fixing 2 mm thick heterogeneous PVC (poly vinyl flooring) EN (European Standard) with wear layer is 0.55mm thick of PVC, total weight is 2300 g/m2 approx. PUR (polyurethane reinforced), residual indentation approx.0.05 mm, castor wheel test qualified, dimensional stability ≤0.10%, static electrical charge .The floor finish should termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto100mm. Recommended to use in area like Patient rooms , Doctor room Lecturer room, Kids area, School, Colleges, Residential and all commercial official scope etc. 536 11.70 Providing and fixing 8mm and above thick laminated (wooden flooring) of AC4 and above grade product of approved made out of core high density fibre board (HDF), surface layer shall be high preasure laminated treated for abrasion, scratch, moisture protection, flame protection U.V resistant, layer of acrylic resin, aluminium oxide or similer layer having above properties, backing under layer on min 2 mm thickness shall provide as sound absorbent and moisture protection layer, The seamless impregenated decorative layer of specified size, design, colour and pettern, all bonded together under high temperature and pressure with eco-friendly. The material shall be applicable warranty formaldehyde free, eco- friendly and fully recyclable (eco-freindly) and matching shed and excluding quantity of skirting and profile. 537 11.71 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, 1:6 (1 cement : 6 sand) including filling the joints with same mortar, with common burntclay non modular bricks 11.71.1 100 mm thick 11.71.2 200mm thick 538 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade 11.72.2 60 mm thick C.C. paver block of M-35 grade 11.72.3 60 mm thick C.C. paver block of M-30 grade 539 11.73 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- Charge). 540 11.74 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side(top & bottom), including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-Charge. 541 11.75 Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. 11.75.2 Granite Door frame for 200mm thick wall Thickness. 542 11.76 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.76.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 543 11.77 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 77.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 544 11.78 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 78.1 In light shade glossy/ rustic /stain finished 11. 78.1.1 Size 600X600 mm thickness 9-10 mm 11. 78.1.2 Size 800X800mm thickness 11-12mm 11. 78.1.3 Size 800X1200 mm thickness 11-12mm 11. 78.2 In dark shade glossy/ rustic /stain finished 11. 78.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 78.2.2 (b) Size 800X800mm thickness 11-12mm 11. 78.2.3 (c) Size 800X1200 mm thickness 11-12mm 545 11.79 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 79.1 In light shade glossy/ rustic /stain finished 11. 79.1.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.1.2 (b) Size 800X800mm thickness 11-12mm 11. 79.1.3 (c) Size 800X1200 mm thickness 11-12mm 11. 79.2 In dark shade glossy/rustic/stain finished 11. 79.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.2.2 (b) Size 800X800mm thickness 11-12mm 11. 79.2.3 (c) Size 800X1200 mm thickness 11-12mm 546 11.80 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 80.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 80.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.1.2 (b) Size 600X600mm thickness 9-10mm 11. 80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 11. 80.2 In dark colour and shade etc. 11. 80.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.2.2 (b) Size 600X600mm thickness 9-10mm 11. 80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 547 11.81 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting, riser laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm 548 11.82 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm 11. 82.1.2 Size 800X800mm thickness 11-12mm 11.82.1.3 Size 800X1600 mm thickness 11-12mm 11.82.1.4 Size 1000X1000 mm thickness 11-12mm 11. 82.1.5 Size 600X1200 mm thickness 11-12mm 11. 82.1.6 Size 800X1200 mm thickness 11-12mm 11. 82.1.7 Size 1200X1200 mm thickness 11-12mm 11.82.1.8 Size 1200X1800 mm thickness 11-12mm 11.82.1.9 Size 1200X2400 mm thickness 11-12mm 11. 82.2 For wall stain / rustic finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e.within 6 hours, Size 300X600 mm thickness 9-10 mm 11. 82.3 For wall polished / Glossy finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e. within 6 hours, Size 300X600 mm thickness 9-10 mm 549 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11. 83.1 For skirting, risers etc. glossy/ rustic /stain/matt finished in all colours and shades 11. 83.1.1 Size 600X600 mm thickness 9-10 mm 11. 83.1.2 Size 800X800mm thickness 11-12mm 11. 83.1.3 Size 600X1200 mm thickness 11-12mm 11. 83.1.4 Size 800X1200 mm thickness 11-12mm 550 11.84 Granite work gang saw cut (polished machine cut) of thickness 12 mm for wall lining, skirting, risers of steps and dado (veneer work), back filling with a grout of average 12 mm thick in cement mortar 1:3 (1 Cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the beaching by means of cramps, which shall be paid for separately). 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 84.1.3 Gray/Pink/Brown with various patterns 551 11.85 Providing and laying gang saw cut 12mm thick, mirror polished pre moulded (wherever required) and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in flooring laid over 20mm thick base of cemnt mortar 1:4(1cement:4sand) including grouting the joints with white cement mixed with matching pigments, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 85.1.3 Gray/Pink/Brown with various patterns 552 11. 86 Providing and fixing artificial synthetic green long and fine yarns grass, UV/water resistant with SBR latex backing eco-friendly durable high density 100 % PP ( Poly Poplin ) anti UV fiber.denier 12000 dtex, stich rate 18 stiches per 10cm, stich density 16800 stiches/m2, tufted weight 1830g/sqm approx. 11. 86.1 Roll size will be 25.00m X 2.00m (25mm thick)- weight 150kg- per roll. 11. 86.2 Roll size will be 25.00m X 2.00m (40mm thick)- weight 180kg- per roll. 553 11.87 Providing and fixing laminated (engineered wooden flooring) of suitable thickness 10-14 mm of suitable grade category product of approved made out of core high density fibre board (HDF) &other component it treated for abrasion ,scratch ,moisture protection, flame protection,U.V resistant. backing with eco- friendly resins specified by the manufacturer .The material shall be applicable warranty formaldehyde free, eco friendly, highly recommended for high traffic area and fully recyclable and matching shed and excluding quantity of skirting and profile. 554 11.88 Providing and fixing single layer homogeneous (solid wooden flooring) of suitable thickness 14 - 18 mm of suitable grade category product of scratch protection, moisture protection, flame protection U.V. resistant, backing under layer on min 2 mm thickness The material shall be applicable warranty formaldehyde free, eco friendly ,highly recommended for high traffic area and fully recyclable and matching shade and excluding quantity of skirting and profile. 555 11.89 Providing and fixing tuffed 1/10” loop pile (carpet tile / Carpet). EN (Euorpean Standard) size 50cm x 50cm /roll Size of total thickness 5.5 mm and above with total mass of 4100g/m2approx and with polyester fleece primary backing with standard dimensional stability with impact sound / noise reduction and recommended for high traffic acoustical area. 556 11.90 Providing and fixing spc (stone plastic composite) virgin pvc water resistant proof vinyl flooring with a thickness between 4 to 8mmuv coated layer with a wear layer of 0.3 to 0.80mm with a SPC core layer of 2.00 to 5.00 mm with a SOP of heat resistant, voc free, easy to cut, anti microbial protection in the form of tiles, planks helpful in environmental of profection health. 557 11.91 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone tile flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with white cement mix with matching pigment etc. complete as per direction of Engineer-in-Charge. 11. 91.1 300x300mm 11. 91.2 400x400mm 11. 91.3 600x600mm 558 11.92 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone slab flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size of area more then .50 sqm and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with cement mix matching pigment etc. complete as per direction of Engineer -in-Charge. 559 12.1 Providing corrugated G.S. Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00mm thick with zinc coating not less than 275gm/m² 12.1.2 0.80mm thick with zinc coating not less than 275gm/m² 12.1.3 0.63 mm thick with zinc coating not less than 275gm/m² 560 12.2 Straight cutting in G.S. sheet of any thickness roofing for making opening of area exceeding 40 sq. decimetre for chimney stacks, sky light etc. 561 12.3 Extra for circular cutting in C.G.S. sheet of any thickness roofing for making opening of area exceeding 40 square decimetre : 562 12.4 Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² 563 12.5 Providing valleys of 90cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350gm/m² 564 12.6 Providing and Fixing of 40 cm over all width plain, G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1cement : 3 sand). 1.00mm thick with zinc coating not less than 275gm/m² 565 12.7 Providing and fixing 15 cm wide 45 cm over all semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² 566 12.8 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia.G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 567 12.9 Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.. 568 12.10 Extra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated/ semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter. 569 12.11 Extra for providing and fixing wind ties of 40x 6 mm flat iron section. 570 12.12 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. 12.12.1 Corrugated serrated adjustable ridges 12.12.2 Plain wing adjustable ridges 12.12.3 Close fitting adjustable ridges 12.12.4 Unserrated adjustable hips 571 12.13 Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: 12.13.1 Corrugated apron pieces 12.13.2 Eaves filler pieces 12.13.3 North light curves 12.13.4 ventilator curves 12.13.5 Barge boards 12.13.6 Ridge finials 12.13.7 Special north light curves 12.13.8 S type louvers 572 12.14 Providing flat iron brackets 50x3mm size with necessary bolts, nuts washers etc. for fixing G.S. sheets gutters with purlins. 573 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 574 12.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete : 12.16.1 Ridges plain (500 - 600mm). 12.16.2 Flashings/ Aprons.( Upto 600 mm) 12.16.3 North light curves. 12.16.4 Barge board (Upto 300 mm) 12.16.5 Crimp curve 12.16.6 Gutter. (600 mm over all girth) 575 12.17 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. 12.17.2 2mm thick flat. 576 12.18 Providing and Fixing of sky lights consisting of Multi cell/tight cell Polycarbonate Panel System of approved colour, 16 mm thick (minimum) having uniform in color with an integral Tight-Cell core constructed not to exceed 4mmx4mm in a cross section, involved such as bolts nuts and screws etc. and labour for cutting bending to required profile, necessary scaffolding, hoisting in position etc. for proper completion of the work etc. complete as per specification drawings and direction of Engineer in charge. Finished surface area of roofing fixed over steel tubular structure shall be measured for payment. MS tabular frame work shall be measured separately for payment. 12.18.1 10mm thick 12.18.2 16mm thick 577 12.19 Providing sand stone slab 40 to 50 mm thick for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately) including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 sand ) complete : 12.19.1 Red sand stone slab 12.19.2 White sand stone slab : 578 12.20 Painting top of roofs with residual type petroleum bitumen of grade VG 10 of approved quality @ 17kg per 10 sqm impregnated with a coat of sand at 60 cum per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 579 12.21 Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall be strictly as per manufacturers specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., and washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-charge. 580 12.22 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 581 12.23 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 sand) and finished neat complete. 582 12.24 Providing and fixing on roof pressed clay tile (Mangalore tile) 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 583 12.25 Providing and laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness of approved pattern on steel frame work complete (steel frame work to be paid separately) 584 12.26 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase 585 12.27 Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. 586 12.28 Providing and fixing M.S. holder bat clamps of approved design to C.I. Or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter 12.28.2 150 mm diameter 587 12.29 Providing and fixing ISI marked sand cast iron rain water pipes. 12.29.1 100 mm dia minimum wall thickness 5mm 12.29.2 150 mm dia minimum wall thickness 5mm 588 12.30 Providing lead caulked joints to sand cast iron rain water pipes and fittings : 12.30.1 100 mm dia. Pipe 12.30.2 150 mm dia. Pipe 589 12.31 Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) : 12.31.1 Sand cast iron bend : 12.31.1.1 100 mm diameter 12.31.1.2 150 mm diameter 12.31.2 Sand cast iron plain shoes : 12.31.2.1 100 mm diameter 12.31.2.2 150 mm diameter 590 12.32 Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) 591 12.33 Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) 12.33.1.2 110 mm (minimum wall thickness 2.2mm) 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) 12.33.2.2 110 mm (minimum wall thickness 2.2mm) 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) 592 12.34 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.34.1 75 mm (minimum wall thickness 1.8mm) 12.34.2 110 mm (minimum wall thickness 2.2mm) 593 12.35 Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. 594 12.36 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. 595 12.37 Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand) 12.37.1 Stone ware spout 12.37.2 Upvc spout (Pipe dia.110 mm) 596 12.38 Providing and fixing of self-supported mechanically seamed roofing system, made of high quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A 792 M of base metal thickness from 0.8 mm to 1.6mm (tolerance ± 0.02mm). High grade steel sheet should have 55% aluminum and 45% zinc coating by hot-dip process of minimum 25 micron The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers/clamps for installation of lighting /fixtures /utility/ duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 12.38.1 Base metal thickness 0.8mm up to span 15 meter 12.38.2 Base metal thickness 0.9mm , up to span 18 meter 12.38.3 Base metal thickness 1.0 mm, up to span 21 meter 12.38.4 Base metal thickness 1.1 mm, up to span 23 meter 12.38.5 Base metal thickness 1.2mm, up to span 25meter 12.38.6 Base metal thickness 1.3 mm, up to span 27 meter 12.38.7 Base metal thickness 1.4mm, up to span 29meter 12.38.8 Base metal thickness 1.5 mm, up to span 31 meter 12.38.9 Base metal thickness 1.6 mm, up to span 33 meter 12.38.10 Providing and fixing galvalume 1.0 mm thick clamps/hangers of size 75X140mm with saddle of 50mm dia, riveted at one side and nut and bolt at other side, to self-supported roofing system by mechanical seaming to suspend light fixture/cable stay/false ceiling/duct etc., at their location which should be planned earlier by engineer-in-charge. Clamps shall be fixed during seaming of panels. 12.38.11 Providing and fixing advanced type hurricane turbo ventilator to self- supporting roof having neck dia 600mm made of aluminum having 24 nos vertical vanes made of aluminum sheet. Ventilator should be fixed on 1 to 2mm thick G.I. ring which shall be fixed on 2mm thick polycarbonate sheet. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates i/c of all material, labour fittings screw, rings, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 12.38.12 Providing and fixing of 2mm thick polycarbonate sheet to self-supported roofing system. The sheet shall have tensile strength and elongation as per ASTM D 638, refractive index as per ASTM D 592, light transmission as per ASTM D 1003 and specific gravity as per STM D 792. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates include of all material, labour, fittings, screw, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 597 12.39 Supply, fabrication and erection of three-dimensional space frame steel structure consisting of support node, primary space frame members, space notes nodes, bolts, sleeves (nut), purlin stool, purlin etc. to support roof sheet in plain or curved shape. (Approximate zinc coating thickness 77 Microns) and shall not be less than 400 g/sqm (Approximate zinc coating thickness 56 microns). Bolts, sleeves and cones shall be electro-galvanized to ASTM B 633 Type 2, SC3. Shop drawings along with structural design analysis shall be provided by the manufacturer for approval of the engineer in charge. Rate shall include cost of design, all material, all lifts, labour, transport, storage, machines, tools and plants, wastages, erection and installation at site all necessary scaffolding etc. necessary to provide finished product but excluding cost of erection/construction of support shaft and roof sheet. 598 12.40 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). 599 12.41 Providing and fixing in position roof tile under lay using 12mm thick(minimum) Moisture/fire Resistance heavy duty fibre cement board(High Pressure Steam Cured) Type A,Category 4 conforming to IS 14862:2000, fixed on Steel frame work of 610mmx610mm or 610mmx1220mm grid by counter sunk stainless screw @ 300mm C/C all complete as per the drawings. Tiles etc may be laid on the board substrate by sealing the joints properly with filler material or sealant to ensure no leakage through joints. All complete as per drawings, specification and as per direction of Engineer-in-Charge.Note - MS Section structure and roof tile like Shingles/Mangalorian Tiles etc cost will be paid seprately. 600 12.42 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 601 12.43 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183, density 16kg/m3, 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 602 12.44 Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge : 603 12.44.1 With Type N - Normal 50 mm thick 604 12.44.2 With Type SE - Self Extinguishing type 50 mm thick. 605 12.45 Providing and laying thermal insulation of roofing with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 mx2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 606 12.46 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge. 607 12.47 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 608 12.48 Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire. 609 12.49 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge. 610 12.50 Supply and application of 48kg/m3 density & 50 mm thick with a tolerance of -2 + 6mm of Rockwool RB slabs unfaced (Binder<3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non- combustible when tested as per BS 476 Part 4 or A1 when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 611 12.51 Supply & Application of Rockwool RB slab 48kg density, 50mm thick wrapped in 200G vergine polythene bags for partition, ceiling (Under Deck insulation) conforming to IS: 8183 with tolerance of -2 +6mm of rock wool RB slabs unfaced (Binder <3.5%) conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested per EN 13501. . Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 612 12.52 Supply & Application of Rockwool RB 2 slab 64kg /m3, 50mm thick, with GI wire netting 24 SWG; fixing for NRC Value 1.00 for Acoustics, thermal & fire purpose conforming to and IS: 8133, IS: 8183 with tolerance of -2 + 6mm of RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Two random samples from each supplied batch will be tested for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 613 12.53 Supply & Application of Rockwool building roll (1.1mx10m) 48kg density, 50mm thick with FSK (foil scrim Kraft) aluminium foil facing for HVAC duct & building underdeck purpose conforming to IS: 8183, IS: 8183 and IS:8183 a tolerance of -2 +6 mm of Rockwool RB slabs unfaced (Binder < 3.5%) ; conforming to IS: 8183; /ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS: 476 Part 4 or Al when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and it shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 614 12.54 Supply & Application of Rockwool Building Roll (1.1mX10m) 48kg density, 50mm thick with ALG (Alu & glass) mixture of Aluminium & glass facing for building underdeck application below metal sheet also conforming IS: 8183, IS: 8183 and IS: 8183 a tolerance of -2+6mm of rockwool RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested as per EN 13501. The maximum service temperature shall be 700°C. Shot content should be less than 2% for 500 microns & less than 10% for 250 microns when tested as per standard IS: 3144. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 615 12.55 Providing and fixing of minimum 12mm thick, 5 layered bubble Reflective thermal insulation made of 12 microns aluminum foil with minimum 97% Reflectivity on both outer sides, under both aluminum foil 4mm thick FR bubble insulation with Low Emissivity - 0.032 (ASTM1371), Fire Class A (ASTM E84) All five layers of insulation shall be stick with each other by registered manufacturer using hot process without using any kind of adhesive. Insulation shall be supplied in 1.10m wide roll width with 50mm wide factory-made cuts at both sides to joint another roll by using general stapler in case of new shed and adhesive in case of existing or self-supported roof. 12.55.1 Fixing of insulation on new work by laying horizontally on the purlins and perpendicular to the direction of purlins and fixing by using self- tapping screws at equal distance. Place and align the second roll of insulation parallel to the first roll and overlaps the adjacent rolls. After Insulation is fixed over the purlins the metal sheet is placed over insulation and drilled with self-tapping screws with purlins etc. complete, including all material and scaffolding. 12.55.2 Installation of insulation in Old Sheds where the sheets have been already fixed over the purlins so insulation shall be fixed under the purlins covering the roof bottom. Insulation roll to be unfolded at the bottom of the purlin horizontally and parallel to the roof and fixed by using the self- tapping screw with a washer at equal distance etc. Complete, including all material and scaffolding. 12.55.3 Insulation of Self-Supported Roof shall be applied under the roofing by using stud welding to the self- supported roof at a distance not be more than 300 mm in both directions. At each stud insulation roll shall be pushed against the studs so that it gets punctured and then non-returning washer has to be applied at the stud etc. complete, including all material and scaffolding. 616 12.56 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over- deck on ceiling surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM C 518, compressive strength of > 350 kPa listed as per ASTM C 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption < 1% by volume as per ASTM C 272, oxygen index of minimum 24 as per ASTM D 2863 and Fire retardant property as per DIN 4102, with preferred stone or pre-cast tiles shall be laid over the XPS board with suitable grouting including providing pre-fabricated EPDM drain outlets (Cement Screed casting shall be done at the junction of roof and parapet walls), all as per the directions of Engineer-in-charge. 617 12.57 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 618 12.58 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board 12.58.1.1 Flat surfaces 12.58.1.2 Curved surfaces 12.58.1.3 Sunk or raised mouldings 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks). 12.58.2.2 Fire resistant Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) 12.58.2.3 Gypsum moisture resistant board. 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 619 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of mainT runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.59.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 12.59.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a ompletely sealed unit. 12.59.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 12.59.5 Glass fiber Acoustical Suspended Ceiling System with 16 mm thick tegular edge or micro look edge tiles of size 595x595mm.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥83%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and7) in module size of 600 x 600 x 16mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38 - 41%. The Tile and Grid system used together should carry a 15 year warranty. 12.59.6 8mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primedcolour tiles of size 595X595 mm. 12.59.7 6mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primed colour tiles of size 595X595 mm. 620 12.60 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm center to centre, suspending the main C carrier and in direction perpendicular to it at 600mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in/swing down tiles into spring T with 12.60.1 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.60.2 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 621 12.61 Providing & Fixing of Unperforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width and height of 32mm. The Tile will be manufactured on advanced equipment that includes several levelling stages in the manufacturing process by approved certified manufacturers. The Tile shall be clipped into clip in rail of 0.5mm thick G.I. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G.I.Road, Hold on Clamp with Clip. (Rate include all materials and labour). 622 12.62 Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately): 12.62.1 12mm thick insulating board 12.62.1.1 Natural colour insulating board 12.62.1.2 White face insulating board 12.62.1.3 Flame retardant face insulating board 12.62.2 Flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete 12.62.3 6 mm thick plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete 12.62.4 6mm thick High Pressure Steam Cured non asbestos, reinforced with cellulose fibres,Moistur& fire Resistance heavy duty fibre cement board, Type A,Category 4 conforming to IS 14862:2000.(for wet areas) 12.62.5 4 mm thick High Pressure Steam Cured non asbestos, pre-painted, self- embossed, designer cement boardType B, Category 3 conforming to IS 14862:2000 . of approved texture,design patterns 623 12.63 Extra for Circular cutting and wastages in ceiling with: board only (frame work) Natural colour insulating 12 mm thick board paid separately. 624 12.64 Extra for providing and fixing ceiling to curved surfaces in narrow widths 625 12.65 Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminium primer on both sides and edges including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately). 626 12.66 Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape 627 12.67 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles. 628 12.68 Providing and fixing expanded polystyrene (thermacol) false ceiling (frame work to be paid separately) : 12.68.1 With Type N - Normal 50 mm thick 12.68.2 With Type SE - Self Extinguishing type 50 mm thick 629 12.69 Providing and fixing false ceiling with fabric fixing with nail etc. (frame work and beading to be paid separately). 12.69.1 costing upto 70/- per metre, 12.69.2 Rs 70- 150 per meter 12.69.3 Upto 200 per meter 630 12.70 Providing and fixing perforated Aluminium panel ceiling of white/ natural satin colour supplied by approved manufacturers consisting of panel of standard size with bevel edge, panel length up to 6 m, coil Coated on a Continuous Paint Line suitable for Interior application, double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 5050 (Al. Mg) for higher strength and good roll forming characteristics. Panel carrier shall be suspended by means of G.I. threaded rod having 6 mm diameter at a distance of 1.5 mtr. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.70.1 With panels of size 300mm wide X30mm deep X 0.7mm thick and panel carrier of size 40.5mm wide X 62mm deep X 0.9mm thick 12.70.2 With panels of size 150mm wide X 15.5 mm deep X 0.5mm thick and panel carrier of size 32mm wide X 39mm deep X 0.95mm thick 12.70.3 With panels of size 84mm wideX16mm deep X 0.5mm thick and panel carrier of size 62mm wide X 29mm deep X 0.95mm thick 631 12.71 Providing and fixing un-perforated Aluminium Panel ceiling Supplied by approved manufacturers of standard white/ natural satin shade consisting of panel 30 mm/80mm/130mm/180mm wide X 15 mm deep X 0.5mm /0.6mm thick respectively, with square edges having panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 5050 (Al.Mg) for higher strength and good roll forming characteristics. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter, and a Galvanised suspension spring clip at a distance of 1.7mtrs centre to centre. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 632 12.72 Providing and fixing U Baffle Aluminium panel ceiling of different colors and finish supplied by approved manufacturers, consisting of panel size 50 mm width X 100 mm deep using 0.6 mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. As an option, ceiling area above U Baffle can be painted by the contractor in black colour or any other colour as per the architect for better aesthetics before fixing this system. 12.72.1 Standard White / Natural Satin Shade 12.72.2 Wooden Finish 633 12.73 Supply & Fixing of perforated G.I false ceiling tile or plank using torsion spring fixing system supplied by approved manufacturer comprising of tile of 600 mm wide and 600 mm long manufactured out of 0.5 mm thick or plank of 600mm wide and 1200 mm long manufactured out of 0.6mm thick galvanised steel perforated with 2 mm dia. at a distance of 5mm centre to centre. Non-woven felt made of glass- reinforced fibre glued over the perforation at the back side of panels to provide noise reduction co efficient up to 0.7 NRc. “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross runners 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced at a spacing of 600 mm on centre maximum. The measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.73.1 Tile of 600 mm wide ,600 mm long and 0.5 mm thick 12.73.2 Plank of 600mm wide ,1200 mm long and 0.6mm thick 634 12.74 Providing and fixing of composite perforated Gypsum board with Glass wool Fiber panel of Size 595x595x25 mm with 10mm square Perforation tiles false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “ “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 635 12.75 Providing and fixing of Composite perforated MDF board with Glass wool Fiber panel of Size 595x595x18 mm 10mm Square Perforation tiles (Square /Tegular Edge) false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 636 12.76 Providing and fixing of Perforated Gypsum board with Acoustical Glass Fiber Tissue faced panel of Size 595x595x12.5mm, Square 10mm Perforation tiles (Square Edge) false ceiling panels in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 637 12.77 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance≥ 85%, Thermal Conductivity k = 0.052 -0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 638 12.78 Providing and fixing false ceiling at all heights with 15 mm thick integral densified micro look edged non- cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.80 grams per sqm) i.e. 50 mm long, 12 mm outer diameter M-6 dash fasteners with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 639 12.79 Providing and fixing false ceiling at all heights with 15 mm thick integral densified mirolook edge with BIO SAFE coating as per ISO 7251:2005, ISO 20743:2007 and ISO 21527-1:2008, making the tiles resistant to bacterial growth in case of any external bacterial contact made onto the surface of tiles, non-cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 640 12.80 Providing and fixing in position wall panelling at all heights with 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles., non-cementitious, reinforced with fibre and natural filler, having NRC (Noise Reduction Coefficient) of 0.10-0.20 for plain and designer 0.15-0.40 for pinhole texture and NRC 0.45-0.65 for fully perforated tiles as per IS 8225:1987, sound attenuation STA-32db. of 0.75 (minimum) as per IS 8225:1987, Light Reflectance of 85% (minimum), non-combustible as per BS:476 (part-4), 50-52% recycled content including fly ash, The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturers specification as per direction of engineer-in-charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles. 641 12.81 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 12.81.1 With semi perforated 12mm thick micro tegular edged GRG false ceiling tiles. 12.81.2 With fully perforated 10mm thick square edged GRG false ceiling tiles for sound proof and acoustic. 642 12.82 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped 387alvanized steel sections (387alvanized387 @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cros‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer- in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 643 12.83 Providing and fixing upvc plank, Plank size (340 X 2700 ) mm as per approved shade, the panel shall be laser catted end of plank fixing j-trim fixed and corner edge of ceiling fixed u pvc clip same colour and providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 125 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular,j trim end clip includes in this item any other item not be paid sepratly complete in all respect as per the directions of Engineer-in-Charge. . 644 12.84 Providing & Fixing PVC ceiling system profile panel with click system interlock panel size 4000mmx340mmx1mm resistance to weather perfect finish in wood grain & solid colour maintenance free Resistance to weather truly anti bacterial. with edge profile J-trim on periphery & center profile T-trim in panel joint Complete System to be fixed on G.I. framework of ceiling section at 450 mm distance with enter section suspended by roof by G.I. angle hanger in proper line & level etc complete . PRODUCT SPECIFICATIONS: Meets or exceeds the standard specification of (ASTM D-4477) and its referenced documents. observed. (Tested at 50 LBS) Tensile strength, MPa: >37.0 Tensile modulus, MPa: >2000 Surface distortion: None at 120F Squareness: <1/8” of square Length: Within ¼” of specification Lock control: Complies Color Change: <2 grayscales (16 hrs under 1200W/m2 UV radiation at 50 degrees) 645 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener, clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding in proper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PUpaint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) 12.85.2 With precontraint tensile membrane 1050 GSM (15 Years warranty) 646 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement : 4 sand) 13.1.2 1:6 (1 cement : 6 sand) 647 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement : 4 sand) 13.2.2 1:6 (1 cement : 6 sand) 648 13.3 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement : 4 sand) 13.3.2 1:6 (1 cement : 6 sand) 649 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) 13.4.2 1:4 (1 cement : 4 sand) 650 13.5 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 13.5.1 1:3 (1 cement : 3 sand) 13.5.2 1:4 (1 cement : 4 sand) 651 13.6 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand). 652 13.7 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 sand) finished rough with sponge. 653 13.8 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) 654 13.9 6 mm cement plaster 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 655 13.10 Neat cement punning 656 13.11 Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. Finished with ordinary cement. 657 13.12 Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. 658 13.13 Providing sand faced plaster upto 10meter hight above ground level concrete or brick masonry surfaces in two coats, base coat of 13 mm thick in cement mortar 1:4 (1 cement: 4 sand), clearing the surface by combing it and finishing coat of 8 mm. thick in cement mortar 1:3 (1 cement: 3 sand) and taking out surface grains by mechanical arrangement or applying second coat by mechanical means including cost of all material, labour, and T and P including all lead, lift and scaffolding etc. complete. 659 13.14 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 660 13.15 Extra for plastering 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof 661 13.16 Extra for plastering on circular work not exceeding 6 m in radius: 13.16.1 In one coat 13.16.2 In two coats 662 13.17 Extra for plastering done on moulding cornices or architraves including neat finish to line and level: 13.17.1 In one coat 13.17.2 In two coats 663 13.18 Extra for plastering Spherical, Groined ceiling, Flewing soffits. 13.18.1 Spherical ceiling 13.18.2 Groined ceiling 13.18.3 Flewing soffits 664 13.19 Washed stone grit plaster on exterior walls of height upto 10 M. above ground level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings,complete as per specification and direction of Engineer- in- charge (Payment for providing grooves shall be made separately). 665 13.20 Forming groove of uniform size 20 or 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 666 13.21 Extra for washed grit plaster on exterior/interior walls of height more than 10m from ground/floor level for every additional height of 3 m or part thereof. 667 13.22 Extra for washed stone grit plaster on circular work not exceeding 6m in radius (in two coats). 668 13.23 Forming groove of uniform size from 12x12mm and upto 25x15mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 669 13.24 Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster. 670 13.25 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part -1 and II) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations,excluding in wall which may come in contact with dampness finished in smooth line and level etc. complete. 671 13.26 Extra for addition of synthetic Polyester triangular fibre of length 6mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125gms. Of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge. 672 13.27 Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete 673 13.27.1 G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height. 13.27.2 Providing and fixing fibre mesh of 145 GSM weight in required width with cement mortar before plastering upto 10m height. 674 13.28 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 sand) : 13.28.1 Flush Band 13.28.2 Sunk Band 13.28.3 Raised Band 13.28.4 Moulded Band 675 13.29 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 sand): 13. 29.1 Flush Band 13. 29.2 Sunk Band 13. 29.3 Raised Band 13. 29.4 Moulded Band 676 13.30 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 sand) top layer 6mm thick with cement mortar 1:4(1 cement : 4 sand). 677 13.31 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 sand) : 13.31.1 Flush / Ruled/ Struck or weathered pointing. 13.31.2 Raised and cut pointing 13.31.3 Sunk pointing 678 13.32 Pointing on stone work with cement mortar 1:3 (1 cement: 3 sand). 13.32.1 Flush/ Ruled pointing 13.32.2 Raised and cut pointing 679 13.33 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3 marble dust) 680 13.34 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 sand): Flush/ Ruled pointing 681 13.35 Extra for pointing on walls on the outside/inside at height more than 10 metre from ground/floor level for every additional height of 3 m or part there of. 682 13.36 Providing and fixing broken glass in cement mortar 1.3 including cost of mortar, over compound walls. 683 13.37 Providing and fixing writing board green writing with chalk (regular modified polyster coated steel surface). of sizes. 13.37.1 size 1200mmx1800mm 13.37.2 size 1200mmx2400mm 13.37.3 size 1200mmx3000mm 684 13.38 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 685 13.39 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. 686 13.40 Extra for lining out plaster to imitate stone or concrete blocks walling. 687 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. 688 13.42 Providing and applying special putty in two coats based materials varnish, Belgium chalk, turpentine oil, white paint, safeda including sand papering for making the surface smooth for applying any or vinyl paints including all cost of material and labouretc complete. 689 13.43 White washing with lime to give an even shade: New work (three or more coats) 690 13.44 Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. 691 13.45 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coat on new work. 692 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work 693 13.47 Distempering by any mechanical or manual means with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.47.1 One coat. 13.47.2 Two coats. 694 13.48 Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.48.1 One coat. 13.48.2 Two coats. 695 13.49 Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. 696 13.50 Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). 697 13.51 Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. 698 13.52 Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface 699 13.53 Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) 700 13.54 Finishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.54.1 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 13.54.2 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. 13.54.3 Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. 701 13.55 Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: 13.55.1 One coat 13.55.2 Two coats 702 13.56 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 13.56.1 On steel work 13.56.2 On concrete work 703 13.57 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. 704 13.58 Applying a coat of mordant solution on G.S. sheet : 13.58.1 With a solution of 38 gms of copper acetate in a litre of soft water 13.58.2 With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water. 705 13.59 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work : 13.59.1 75 mm diameter pipes 13.59.2 100 mm diameter pipes 13.59.3 150 mm diameter pipes 706 13.60 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 13.60.1 75 mm diameter pipes 13.60.2 100 mm diameter pipes 13.60.3 150 mm diameter pipes 707 13.61 Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) 708 13.62 Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. 709 13.63 Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively. 710 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 711 13.65 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 712 13.66 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.66.1 One coat. 13.66.2 Two coats. 713 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. 13.67.2 With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 714 13.68 Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work. 715 13.69 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. 716 13.70 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 717 13.71 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work 718 13.72 Varnishing with varnish of approved brand and manufacture: 13.72.1 Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. 13.72.2 Two or more coats glue sizing with spar varnish or an under coat of flatting varnish. 719 13.73 French spirit polishing: Two or more coats on new works including a coat of wood filler. 720 13.74 Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work. 721 13.75 Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. 722 13.76 Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler. 723 13.77 Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. 724 13.78 Lettering with black Japan paint of approved brand and manufacture. 725 13.79 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. 726 13.80 Providing and applying Granules homogeneous wall finishing system consisting of a two component system of dry granules (25 kgs/pack) made of 92% silica particles coated with fade resistant pigments and a 100% acrylic Polymer Bonding agent (5 kgs/pack) with the applied thickness of coating as required to be applied in single coat, on a cured. Smooth level plaster surface without keying as per the shades/combinations approved. As per the manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per the directions/supervision of engineers in charge, all complete inclusive of primer on the base. 13.80.1 0.8-1.2mm thickness 13.80.2 2.0-2.5mm thickness 727 13.81 Providing and Applying Roto Wall finishing system being a dispersion of inorganic fillers, calcite, pure silica, quartz and broad spectrum fungicides stabilized by an acrylic co-polymer, to be applied by means of customized trowels (one for incorporating material on base and spreading and other for finishing) in single coat with a coating thickness of 2.0-2-2.5mm on a cured smooth level plaster without keying, by the approved applicator of manufacturer, of the approved shade as per directions for usage all inclusive including primer coat on the base. 728 13.82 Providing and plastering over AAC masonary wall with polymer modified cement based readymix factory controlled mortar with self curing, eco- friendly, wet premix in a mechanical mixer in thickness as specified below, and covering area of 2.04 kg per sqm/mm thickness. The Bulk density of ready mix plaster may vary from 1300 to 1600 Kg/cum, Water powder ratio (as per manufacture’s direction) may vary from 18-22 % by weight or as specified by the manufacturer and compressive strength may vary from 8-9 Mpa. 13.82.1 6 mm thick plaster for internal walls 13.82.2 8 mm thick plaster for external walls exposed to weather. 729 13.83 Providing and fixing including Designing and UV printing on aluminium composite material (ACM) sheet in different sizes with 720DPI (Dot per inch) 13.83.1 ACP sheet 2mm thick 13.83.2 ACP sheet 3mm thick 13.83.3 ACP sheet 4mm thick 730 13.84 Providing and fixing including designing and UV printing on pvc foam sheet of different size with 720 DPI (Dot per inch) 13.84.1 PVC foam sheet 3.0 mm thick 13.84.2 PVC foam sheet 5.0 mm thick 13.84.3 PVC foam sheet 8.0 mm thick 731 13.85 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 732 13.86 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over outer wall surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM and Fire retardant property as per DIN 4102, Part 1. XPS insulation of thickness 50mm shall be placed over brushed, algae free and levelled external wall by connecting the ship-laps joints and fixed by the washer and Self-Tapping Screw of suitable length at each corner and at distance 75mm from the edge and bitumen shall be applied over the joints and G.I. Expanded Mesh (Barfi Jali) shall be fixed over XPS board by a Self- Tapping Screw of suitable length at the centre of the board and 15mm PCC shall be applied over the board (paint of suitable choice can be used), all as per the directions of Engineer-in-Charge. 733 13.87 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorption < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 734 13.88 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 735 13.89 Scrapping/sand papering of existing surface with the help of mechanized sanding machine (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) as per direction of Engineer-in- Charge. 736 13.90 Providing and applying 1 coat of Triple booster primer-resist dampness, efflorescence, alkali & at the same time improve top coat coverage by 15-20% @1.0 lt/ 10 sqm, which confirms certfication of IS 109/1968. It can be applied by Brush/ Spray Machine and the work shall be carried out as per secification& the direction of the Engineer-in-Charge. 737 13.91 Finishing walls with water based anti- germ paint of with VOC < 50 g/l, that kills disease causing germs, teflon based washability and Anti fungal properties in two or more coats @ 1.08 ltr / 10 sqm over priming coat of interior primer applied @ 1.08 ltr / 10 sqm of required shade including removing of all dust complete as per direction of Engineer- in-Charge and submission of challans of materials on enquiry. 738 13.92 Providing and applying in two coats of 250 micron thick each layer of epoxy coating on prepared surface (cost includes preparing the plastered surface smooth ready to receive epoxy coating) for operation theater walls in desired colour as per direction of Engineer-in-Charge. 739 14.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). 740 14.2 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meters lead : 14.2.1 Door chowkhats 14.2.2 Window chowkhats 14.2.3 Clerestory window chowkhats 741 14.3 Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener. 742 14.4 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish as directed by Engineer- in-charge. For door/ window/ clerestory window. 743 14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm 14.5.2 Float glass panes of thickness 5.5 mm 744 14.6 Renewing glass panes with now wooden fillets wherever necessary: 14.6.1 Float glass panes of thickness 4 mm 14.6.2 Float glass panes of thickness 5.5 mm 745 14.7 Renewing glass panes and refixing existing wooden fillets: 14.7.1 Float glass panes of thickness 4 mm 14.7.2 Float glass panes of thickness 5.5 mm 746 14.8 Supplying and fixing new wooden fillets wherever necessary: 14.8.1 2nd class teak wood fillets 14.8.2 Haldu/Bija/Kail wood fillets. 747 14.9 Renewal of old putty of glass panes (length). 748 14.10 Refixing old glass panes with putty and nails. 749 14.11 Fixing old glass panes with wooden fillets (excluding cost of fillets). 750 14.12 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 751 14.13 Replacing sand stone slabs in roofing laid in cement mortar 1:4 (1 cement : 4 sand) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead : 14.13.1 Red/ white sand stone slabs 30 to 50 mm thick. 752 14.14 Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.14.1 Sal wood battens. 753 14.15 Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.15.1 Not exceeding 4.00 metres in length. 14.15.1.1 Sal wood beams 14.15.1.2 Haldu/Bija/Kail wood fillets. 14.15.2 Above 4.00 metres and upto 5.00 metres length. 14.15.2.1 Sal wood beams 14.15.2.2 Haldu/Bija/Kail wood fillets. 754 14.16 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead. 755 14.17 Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. 756 14.18 Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. 757 14.19 Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 758 14.20 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. 14.20.1 Wheel 50 mm dia. and below. 14.20.2 Wheel above 50 mm dia. 759 14.21 Providing and fixing 25 mm thick shutters for cupboard etc. : 14.21.1 Panelled or panelled and glazed shutters : 14.21.1.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2 Glazed shutters : 14.21.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 760 14.22 Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10mm laths placed 35mm apart (frames to be paid separately) including fixing 50x12mm beading complete with: 14.22.1 Second class teak wood. 14.22.2 Hard wood, finger jointed 761 14.23 Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.23.1 20 mm diameter. 14.23.2 25 mm diameter. 762 14.24 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. 763 14.25 Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with: 14.25.1 Sal wood. 14.25.2 Haldu/Bija/Kail wood. 764 14.26 White washing with lime old work to give an even shade : 14.26.1 two or more coats 14.26.2 one or more coats 765 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 766 14.28 Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. 767 14.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats). 768 14.30 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 769 14.31 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Old work (one or more coats). 770 14.32 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 14.32.1 75 mm diameter pipes 14.32.2 100 mm diameter pipes 14.32.3 150 mm diameter pipes 771 14.33 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture on old work : 14.33.1 75 mm diameter pipes 14.33.2 100 mm diameter pipes 14.33.3 150 mm diameter pipes 772 14.34 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 14.34.1 75 mm diameter pipes 14.34.2 100 mm diameter pipes 14.34.3 150 mm diameter pipes 773 14.35 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 774 14.36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work. 775 14.37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 776 14.38 Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. 777 14.39 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 778 14.40 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: One or more coats on old work. 779 14.41 French spirit polishing: One or more coats on old work. 780 14.42 Mealamine polishing on wood work by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying Mealamine polish with air compressor. One or more coats on old work. 781 14.43 Lacquer polishing on wood work by preparing the surface applying putty base course. prepare the surface smooth by sand papering and then applying Lacquer polish with air compressor 14.43.1 One or more coats on old work. 782 14.44 Polishing on wood work with readymade wax polish of approved brand and manufacture : 14.44.1 Old work 783 14.45 Re-lettering with black Japan paint of approved brand and manufacture. 784 14.46 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 785 14.47 Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : 14.47.1 32 mm dia 14.47.2 40 mm dia 786 14.48 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. As per manufacturers specification. One or more coats on old work. 787 14.49 Finishing walls with water proofing cement paint of required shade : 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. 788 14.50 Finishing walls with textured exterior paint of required shade : 14.50.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 14.50.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. 789 14.51 Finishing walls with Acrylic Smooth exterior paint of required shade : 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). 790 14.52 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). 791 14.53 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. 14.53.2 Painting wood work with Deluxe Multi Surface Paint of required shade. One or more coat applied @0.70 ltr/10 sqm 14.53.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. One or more coat applied @0.70 ltr/10 sqm. 792 14.54 Varnishing with varnish of approved brand and manufacture: 14.54.1 One or more coats with copal varnish. 14.54.2 One or more coats with spar varnish. 793 14.55 Melamine polishing on wood work (one or more coat). Old work 794 14.56 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 795 14.57 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coat on old work. 796 14.58 40 mm thick stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. Red sand stone / White sand stone) stone to be supplied by the department. 14.58.1 Rough chiseled dressed stone 14.58.2 Fine dressed stone 797 14.59 Coursed rubble masonry (second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 sand) (Stone shall be supplied by the department) 798 14.60 Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 799 14.61 Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost). 800 14.62 Colour washing with lime to give an even shade: 14.62.1 (one or more coats) 14.62.2 (two or more coats) 801 14.63 Conducting adequate nos. of scanning to detect the steel reinforcement in existing RCC elements by using ground/ Wall penetrating radar system to avoid the cutting of Main bars during drilling for inserting bolts etc. complete. 802 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. 803 14.70 Rebaring of TMT bars by drilling hole & embedding bars of different diameter using epoxy grouting compound including all tools and tackles complete. 14.70.1 8 mm dia bar 10 mm dia hole 14.70.2 10 mm dia bar 12 mm dia hole 14.70.3 12 mm dia bar 16 mm dia hole 14.70.4 16 mm dia bar 20 mm dia hole 14.70.5 20 mm dia bar 25 mm dia hole 14.70.6 25 mm dia bar 32 mm dia hole 14.70.7 32 mm dia bar 40 mm dia hole 804 14.71 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 14.71.1 125x70x4 mm (ordinary type) 14.71.2 100x70x4 mm (ordinary type) 14.71.3 75x65x4 mm (heavy type) 14.71.4 75x40x2.5 mm (ordinary type) 14.71.5 50x40x2.5 mm (ordinary type) 805 14.72 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. 806 14.73 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 807 14.74 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of f tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 808 14.75 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer- incharge. 809 14.77 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 14.77.1 Bars upto 12 mm diameter 14.77.2 Bars above 12 mm diameter 810 14.78 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 14.78.1 Upto and including 12mm dia 811 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 14.83.1 Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work 14.83.2 Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. 14.83.3 Epoxy injection grout in concrete/RCC work of approved make 812 14.85 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 813 14.88 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-incharge. 814 15.1 Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge. 815 15.2 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). 816 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 817 15.4 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. work (Payment shall be made on the cross sectional area of R.C.C. work) as per direction of Engineer-in- Charge. 818 15.5 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. work. 819 15.6 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 820 15.6.1 In lime mortar with old mughal bricks. 15.6.2 In lime mortar. 15.6.3 In cement mortar. 821 15.7 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : 15.7.1 From brick work in lime mortar. 15.7.2 From brick work in cement mortar. 822 15.8 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge: 15.8.1 In lime mortar. 15.8.2 In cement mortar. 823 15.9 Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge: 15.9.1 In lime mortar. 15.9.2 In cement mortar. 824 15.10 Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) : 15.10.1 In lime mortar. 15.10.2 In cement mortar. 825 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. 15.11.1 For thickness of tiles 10 mm to 25 mm. 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. 826 15.12 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 827 15.13 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 828 15.14 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.14.1 Of area 3 sq. metres and below. 15.14.2 Of area beyond 3 sq. metres. 829 15.15 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: 15.15.1 Of area 3 sq. metres and below. 15.15.2 Of area beyond 3 sq. metres. 830 15.16 Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead: 15.16.1 Of sectional area below 40 square centimetres. 15.16.2 Of sectional area 40 square centimetres and above. 831 15.17 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres : 15.17.1 Of sectional area below 40 square centimetres. 15.17.2 Of sectional area 40 square centimetres and above. 832 15.18 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : 15.18.2 Of sectional area below 40 square centimetres. 15.18.1 Of sectional area 40 square centimetres and above. 833 15.19 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: 15.19.1 R.S. Joists 15.19.2 Channels, angles, tees and flats 834 15.20 Dismantling steel work in built up sections with span upto 10 meter and hieght 5 meter in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 835 15.21 Dismantling steel work manually/ by mechanical means in built up sections with span upto 10 meter and hieght 5 meter without dismembering and stacking within 50 metres lead as per direction of Engineer-in-Charge. 836 15.22 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres 837 15.23 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. 838 15.24 Extra for marking of structural steel work required to be re- erected. 839 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. 840 15.26 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 841 15.27 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: 15.27.1 G.S. Sheet 15.27.2 Asbestos/ Non asbestors sheet 842 15.28 Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 843 15.29 Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 844 15.30 Dismantling wooden ballies in posts and struts including stacking within 50 metres lead. 845 15.31 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : 15.31.1 T’ or ‘L’ iron or pipe 15.31.2 R.C.C. 846 15.32 Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead. 847 15.33 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 848 15.34 Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. 849 15.35 Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. 850 15.36 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.36.1 Upto 10 mm thick 15.36.2 Thickness above 10 mm upto 25 mm 15.36.3 Thickness above 25 mm upto 40 mm 851 15.37 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead: 15.37.1 Thickness upto 40 mm 15.37.2 Thickness above 40 mm upto 75 mm 852 15.38 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. 853 15.39 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 15.39.1 75 to 80 mm dia pipe. 15.39.2 100 mm dia pipe 15.39.3 150 mm dia pipe 854 15.40 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-Charge : 15.40.1 15 mm to 40 mm nominal bore 15.40.2 Above 40 mm nominal bore 855 15.41 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-Charge: 15.41.1 Upto 150 mm diameter 15.41.2 Above 150 mm dia upto 300 mm dia. 15.41.3 Above 300 mm diameter 856 15.42 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 857 15.43 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 858 15.44 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 859 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 860 15.46 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 15.46.1 Upto 150 mm diameter 15.46.2 Above 150 mm diameter 861 15.47 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. 862 15.48 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 863 15.49 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-Charge. 864 15.50 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps: 15.50.1 100 mm diameter 15.50.2 150 mm diameter 15.50.3 200 mm diameter 15.50.4 250 mm diameter 15.50.5 300 mm diameter 15.50.6 350 mm diameter 15.50.7 400 mm diameter 15.50.8 440 mm diameter 865 15.51 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead : 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep 866 15.52 Extra for depth of manholes dismantled: 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). 867 15.53 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge. 868 15.54 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 869 15.55 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 870 15.56 Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 871 15.57 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 872 15.58 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge : 15.58.1 Water bound macadam road 15.58.2 Bituminous road 873 15.59 Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : 15.59.1 Up to 600 mm diameter 15.59.2 Above 600 mm diameter 874 15.60 Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge 15.60.1 Up to 150 mm diameter 15.60.2 Above 150 mm diameter 875 15.61 Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead. 876 15.62 Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead: 15.62.1 120 x 120 cm (outside to outside) 15.62.2 210 x 120 cm (outside to outside) 877 15.63 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in- charge. 878 15.64 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 879 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 17.1.2 Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests. 880 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid 17.2.3 Providing and fixing AISI-304 (18/8) European type WC instead of white vitreous china pedestal type water closet. 881 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. 882 17.4 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with 10 liter low level flushing cistern i/c C.P. flush bend. 883 17.5 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 884 17.6 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 17.6.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. 17.6.3 Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern. 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. 885 17.7 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever require 17.7.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. 17.7.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. 17.7.3 Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. 886 17.8 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.8.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern. 17.8.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern. 17.8.3 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern. 17.8.4 Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern. 887 17.9 Providing and fixing white vitreous china water less urinal of size 600x330x315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. 888 17.10 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge. 889 17.11 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. 17.11.6 White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap. 17.11.7 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap. 17.11.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated lever ISI marked. 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked. 17.11.10 Oval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counter to be paid sepratly). 17.11.11 Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap 17.11.12 Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap. 890 17.12 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 891 17.13 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 892 17.14 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. 17.14.1.2 510x1040 mm bowl depth 225mm. 17.14.1.3 510x1040 mm bowl depth 200mm. 17.14.1.4 510x1040 mm bowl depth 178mm. 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. 17.14.2.2 610x460 mm bowl depth 200 mm. 17.14.2.3 470x420 mm bowl depth 178 mm. 893 17.15 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required : 17.15.1 Size450x300x150mm 17.15.2 Size600x450x200mm 894 17.16 Providing and fixing White glazed fire clay draining board of size 600x450x25mm with C.I. brackets including painting of brackets, cutting and making good the walls wherever required. 895 17.17 Providing and fixing white vitreous china water closet squatting pan (Indian type) 17.17.1 Long pattern W.C. pan of size 580 mm 17.17.2 Orissa pattern W.C. pan of size 580x440 mm 896 17.18 Extra for using coloured W.C. pan instead of white W.C. pan Orissa pattern W.C. pan 580x440 mm 897 17.19 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 898 17.20 Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. 899 17.21 Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 17.21.1 250x130x30 mm 17.21.2 250x125x25 mm 900 17.22 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity 17.22.1 White 17.22.2 coloured 901 17.23 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush capacity) 17.23.1 White 17.23.2 Coloured 902 17.24 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 17.24.1 White 17.24.2 Black 17.24.3 Coloured (other than black and white) 903 17.25 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. 904 17.26 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively. 905 17.27 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm. 906 17.28 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 907 17.29 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : 17.29.1 Flat back wash basin of size 630x450mm. 17.29.2 Flat back wash basin of size 550x400mm. 17.29.3 Angle back wash basin of size 600x480mm. 17.29.4 Angle back wash basin of size 400x400mm. 17.29.5 Flat back wash basin of size 450x300mm. 17.29.6 Surgeon type wash basin of size 660x460mm. 908 17.30 Providing and fixing kitchen sink including making all connections excluding cost of fittings. White glazed fire clay sink of size 600x450x250mm. 909 17.31 Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: 17.31.1 Size 450x300x150 mm. 17.31.2 Size 600x450x200 mm. 910 17.32 Providing and fixing soil, waste and vent pipes: 17.32.1 Sand cast iron socket and spigot (S&S) pipe as per IS: 1729 17.32.1.1 75 mm dia with wall thickness of 5 mm 17.32.1.2 100 mm dia with wall thickness of 5 mm 17.32.2 Spun cast iron socket and spigot (S&S) pipe as per IS: 3989 17.32.2.1 75 mm dia with wall thickness of 3.5 mm 17.32.2.2 100 mm dia with wall thickness of 4 mm 17.32.2.3 150mm dia with wall thickness of 5mm 17.32.3 Hubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) 17.32.3.1 75 mm dia with wall thickness of 3.5 mm 17.32.3.2 100 mm dia with wall thickness of 3.5mm 17.32.3.3 150mm dia with wall thickness of 4 mm 911 17.33 Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 sand) in S.C.I./ C.I. Pipes : 17.33.1 75 mm dia pipe 17.33.2 100 mm dia pipe 912 17.34 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 17.34.1 For 75 mm dia pipe 17.34.2 For 100 mm dia pipe 17.34.3 For 150 mm dia pipe 913 17.35 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.35.1 150 mm dia 17.35.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.35.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.35.2 100 mm dia 17.35.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.35.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.35.3 75 mm dia 17.35.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5 mm 17.35.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.35.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 914 17.36 Providing and fixing plain bend of required degree. 17.36.1 150 mm dia 17.36.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.36.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.36.2 100 mm dia 17.36.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.36.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.36.3 75 mm dia 17.36.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.36.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 915 17.37 Providing and fixing heel rest sanitary bend 17.37.1 100 mm dia 17.37.1.1 Sand cast iron as per IS - 1729 17.37.1.2 Spun cast iron as per IS - 3989 17.37.2 75 mm dia 17.37.2.1 Sand cast iron as per IS - 1729 17.37.2.2 Spun cast iron as per IS - 3989 916 17.38 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.38.1.1 150X150X150X150 17.38.1.2 Sand cast iron as per IS - 3989 17.38.2 100x100x100x100mm 17.38.2.1 Sand cast iron as per IS - 1729 17.38.2.2 Spun cast iron as per IS - 3989 17.38.3 75x75x75x75mm 17.38.3.1 Sand cast iron as per IS - 1729 17.38.3.2 Spun cast iron as per IS - 3989 917 17.39 Providing and fixing double equal plain junction of required degree. 17.39.1 150X150X150X150 mm 17.39.1.1 Sand cast iron as per IS - 3989 17.39.2 100x100x100x100mm 17.39.2.1 Sand cast iron as per IS – 1729 17.39.2.2 Spun cast iron as per IS – 3989 17.39.2.3 Hubless cast(spun) iron as per IS- 15905 17.39.3 75x75x75x75 mm 17.39.3.1 Sand cast iron as per IS – 1729 17.39.3.2 Spun cast iron as per IS – 3989 17.39.3.3 Hubless cast(spun) iron as per IS- 15905 918 17.40 Providing and fixing single equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.40.1 150X150X150 mm 17.40.1.1 Spun cast iron as per IS - 3989 17.40.2 100x100x100 mm 17.40.2.1 Sand cast iron as per IS - 1729 17.40.2.2 Spun cast iron as per IS - 3989 17.40.3 75x75x75 mm 17.40.3.1 Sand cast iron as per IS - 1729 17.40.3.2 Spun cast iron as per IS - 3989 919 17.41 Providing and fixing single equal plain junction of required degree : 17.41.1 150X150X150 mm 17.41.1.1 Spun cast iron as per IS - 3989 17.41.2 100x100x100 mm 17.41.2.1 Sand cast iron as per IS – 1729 17.41.2.2 Spun cast iron as per IS – 3989 17.41.2.3 Hubless cast(spun) iron as per IS- 15905 17.41.3 75x75x75 mm 17.41.3.1 Sand cast iron as per IS – 1729 17.41.3.2 Spun cast iron as per IS – 3989 17.41.3.3 Hubless cast(spun) iron as per IS- 15905 920 17.42 Providing and fixing double unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75x75 mm 17.42.1 Sand cast iron as per IS - 1729 17.42.2 Spun cast iron as per IS - 3989 921 17.43 Providing and fixing double unequal plain junction of required degree: 100x100x75x75 mm 17.43.1.1 Sand cast iron as per IS – 1729 17.43.1.2 Spun cast iron as per IS – 3989 17.43.1.3 Hubless cast(spun) iron as per IS- 15905 922 17.44 Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm 17.44.1 Sand cast iron as per IS - 1729 17.44.2 Spun cast iron as per IS - 3989 923 17.45 Providing and fixing single unequal plain junction of required degree : 100x100x75 mm 17.45.1 Sand cast iron as per IS – 1729 17.45.2 Spun cast iron as per IS – 3989 17.45.3 Hubless cast(spun) iron as per IS- 15905 924 17.46 Providing and fixing double equal plain invert branch of required degree: 17.46.1 100x100x100x100 mm 17.46.1.1 Sand cast iron as per IS - 1729 17.46.1.2 Sand cast iron as per IS - 3989 17.46.1.3 Hubless cast(spun) iron as per IS- 15905 17.46.2 75x75x75x75 mm 17.46.2.1 Sand cast iron as per IS - 1729 17.46.2.2 Spun cast iron as per IS - 3989 925 17.47 Providing and fixing single equal plain invert branch of required degree: 17.47.1 100x100x100 mm 17.47.1.1 Sand cast iron as per IS - 1729 17.47.1.2 Sand cast iron as per IS - 3989 17.47.1.3 Hubless cast(spun) iron as per IS- 15905 17.47.2 75x75x75 mm 17.47.2.1 Sand cast iron as per IS - 1729 17.47.2.2 Sand cast iron as per IS - 3989 17.47.2.3 Hubless cast(spun) iron as per IS- 15905 926 17.48 Providing and fixing double unequal invert branch of required degree : 100x100x75x75 mm 17.48.1 Sand cast iron as per IS - 1729 17.48.2 Spun cast iron as per IS - 3989 927 17.49 Providing and fixing single unequal plain invert branch of required degree : 100x100x75 mm 17.49.1 Sand cast iron as per IS - 1729 17.49.2 Spun cast iron as per IS - 3989 17.49.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 928 17.50 Providing and fixing sand cast iron S&S off sets as per IS: 1729 17.50.1 76 mm off sets 17.50.1.1 With 75 mm dia pipe 17.50.1.2 With 100 mm dia pipe 17.50.2 114 mm off sets 17.50.2.1 With 75 mm dia pipe 17.50.2.2 With 100 mm dia pipe 17.50.3 152 mm off sets 17.50.3.1 With 75 mm dia pipe 17.50.3.2 With 100 mm dia pipe 929 17.51 Providing and fixing sand cast iron S&S off sets as per IS: 3989. 17.51.1 75 mm off sets 17.51.1.1 With 75 mm dia pipe 17.51.1.2 With 100 mm dia pipe 17.51.1.3 With 150 mm dia pipe 17.51.2 150 mm off sets 17.51.2.1 With 75 mm dia pipe 17.51.2.2 With 100 mm dia pipe 17.51.2.3 With 150 mm dia pipe 930 17.52 Providing and fixing door piece, insertion rubber washer 3mm thick, bolts and nuts complete : 17.52.1 100 mm 17.52.1.1 Sand cast iron as per IS - 1729 17.52.1.2 Spun cast iron as per IS - 3989 17.52.2 75 mm 17.52.2.1 Sand cast iron as per IS - 1729 17.52.2.2 Spun cast iron as per IS - 3989 931 17.53 Providing and fixing terminal guard: 17.53.1 150mm 17.53.1.1 Sand cast iron as per IS - 1729 17.53.1.2 Spun cast iron as per IS - 3989 17.53.1.3 Hubless cast(spun) iron as per IS- 15905 17.53.2 100 mm 17.53.2.1 Sand cast iron as per IS - 1729 17.53.2.2 Spun cast iron as per IS - 3989 17.35.2.3 Hubless cast(spun) iron as per IS-15905 17.53.3 75 mm 17.53.3.1 Sand cast iron as per IS - 1729 17.53.3.2 Spun cast iron as per IS - 3989 17.53.3.3 Hubless cast(spun) iron as per IS- 15905 932 17.54 Providing and fixing collar: 17.54.1 100 mm 17.54.1.1 Sand cast iron S & S as per IS - 1729 17.54.1.2 Sand cast iron S & S as per IS - 3989 17.54.2 75 mm 17.54.2.1 Sand cast iron S & S as per IS - 1729 17.54.2.2 Sand cast iron S & S as per IS- 3989 933 17.55 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter: 17.55.1 150mm 17.55.2 100 mm 17.55.3 75 mm 934 17.56 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 17.56.1 100 mm dia 17.56.2 75 mm dia 935 17.57 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.57.1 100 mm inlet and 100 mm outlet 17.57.1.1 Spun cast iron S & S as per IS: 3989. 17.57.1.2 Sand Cast iron S & S as per IS: 1729. 17.57.1.3 Hubless cast(spun) iron as per IS-15905 17.57.2 100 mm inlet and 75 mm outlet 17.57.2.1 Sand cast iron S & S as per IS - 3989 17.57.2.2 Spun Cast iron S & S as per IS- 1729. 17.57.2.3 Hubless cast(spun) iron as per IS- 15905 936 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 17.58.1 75 mm diameter 17.58.2 110 mm diameter 937 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.1 75 mm 17.59.1.2 110 mm 17.59.2 Single pushfit Coupler 17.59.2.1 75 mm 17.59.2.2 110 mm 17.59.3 Single tee with door 17.59.3.1 75x75x75 mm 17.59.3.2 110x110x110 mm 17.59.4 Single tee without door 17.59.4.1 75x75x75 mm 17.59.4.2 110x110x110 mm 17.59.5 Bend 87.50 17.59.5.1 75 mm bend 17.59.5.2 110 mm bend 938 17.60 Providing and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good the wall etc. complete. 17.60.1 75 mm 17.60.2 110 mm 939 17.61 Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet 940 17.62 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x1.6mm galvanised M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts, and washers of size 25x6mm, one bolts on each side of the pipe. 17.62.1 Total bracket length 580mm of approved shape and design (for single, 100mm dia pipe). 17.62.2 Total bracket length 810mm of approved shape and design (for two, 100mm dia pipes). 17.62.3 Total bracket length 1040mm of approved shape and design (for three, 100mm dia pipes). 941 17.63 Cutting chases in brick masonry walls (clay brick/flyash brick/AAC blocks) for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 sand :6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) : 17.63.1 100 mm dia 17.63.2 75 mm dia 17.63.3 50 mm dia 942 17.64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia 17.64.1.2 40 mm dia 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia 17.64.2.2 40 mm dia 943 17.65 Providing and fixing 100 mm sand cast Iron grating for gully trap. 944 17.66 Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design. 945 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 946 17.68 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing 17.68.1 Circular shape 450mm dia. 17.68.2 Rectangular shape 453x357mm 17.68.3 Oval shape 450x350mm (outer dimensions) 17.68.4 Rectangular shape 1500x450 mm 947 17.69 Providing and fixing glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 948 17.70 Providing and fixing toilet paper holder: 17.70.1 C.P. brass 17.70.2 Vitreous china 949 17.71 Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. 17.71.1 Waste coupling 31mm of 79mm length and 62mm breadth 17.71.2 Waste coupling 38mm of 83mm length and 77mm breadth 950 17.72 Providing and fixing CP brass bottle trap of approved quality and make for sink and wash basin. 951 17.73 Providing and fixing CP brass towel rail of approved quality and make 17.73.1 600x20mm 17.73.2 450x20mm 952 17.74 Providing and fixing CP brass towel ring of approved quality and make 200mm dia ring 953 17.75 Providing and fixing CP brass soap dish of approved quality and make 954 17.76 Providing and fixing CP brass Urinal spreader of approved quality and make 955 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approved quality and conforming to IS: specification. 956 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. 957 17.79 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.79.1 Waste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms. 17.79.2 Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60gms. 958 17.80 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.80.1 Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms. 17.80.2 Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms. 959 17.81 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms. 960 17.82 Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms. 961 17.83 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 17.83.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. 17.83.2 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 962 17.84 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. 963 17.85 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 964 17.86 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 965 17.87 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 966 17.88 Painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer (of approved quality) on the outside surface of the cistern, flush pipe, other fittings, etc. complete for new work. 967 17.89 Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W.C. pan with acid wherever necessary. 968 17.90 Repainting C.I. cistern with synthetic enamel paint of approved colour brand and manufacture on the outside surface of cistern flush pipe, other fittings etc. complete. 969 17.91 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 17.91.1 75 mm diameter pipe 17.91.2 100 mm diameter pipe 17.91.3 150 mm diameter pipe 970 17.92 Repainting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff etc : 17.92.1 75 mm diameter pipe 17.92.2 100 mm diameter pipe 17.92.3 150 mm diameter pipe 971 17.93 Repainting bath tub of size 1700x730x430mm with enamel paint. 972 17.94 Providing and laying Ceramic glazed half round pipe drain (having thickness 9 to 10mm) of approved make in colours such as White, Ivory, Grey, or any other colour, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 17.94.1 100 mm dia half round pipe 17.94.2 150 mm dia half round pipe 17.94.3 200mm dia half round pipe 973 17.99 Construction of manually operated fire based incinerator for girls-toilet i/c (i)   Fire and ash collection chamber 0.60x0.60 m, made of calcium silicate bricks, having 12mm dia steel bars grating @10 cm c/c, i/c MS mesh weldedon top including 300 mm x 450 mm MS openable door of half grill and half MS plate (3mm thick ).(ii)     0.40 m X 0.40 m duct made of 1.6 mm thick MS sheet for dropping napkins from the toilet opening.(iv) 150mm dia Class C heavy duty MS pipe conforming to IS 3589/1239 for gas emission with cowel, up to 2.10 meter height above terrace level.(v) Opening in wall having MS flap (1.6mm thick) of size 0.25X 0.25 m, finished with granite.etc complete as per standard drawing no. 5313-B-NB4-9919- R1 dated 21.02.2017 17.99.1 For ground floor buildings. 17.99.2 For Ground floor & Ist floor buildings. 17.99.3 Add extra for every additional floor above Ist floor. 974 17.95 Providing and fixing coupler for PVC pipes & fittings waste/rain water/drainage disposal of superior Indian make (as approved by Engineer incharge) i/c jointing with rubber rings, adhesive, lubricant,solvent cement PVC clips or burried underground i/c making necessary chases and holes in walls, floors or trenching complete with making good or i/c excavation and refilling as per site requirement with testing etc.complete. FOR WASH BASIN CONNECTION (40mm diameter) 975 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia Pipes. 18.6.1.2 20 mm nominal outer dia .Pipes. 18.6.1.3 25 mm nominal outer dia .Pipes. 18.6.1.4 32 mm nominal outer dia Pipes. 18.6.1.5 40 mm nominal outer dia Pipes. 18.6.1.6 50 mm nominal outer dia .Pipes. 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes. 18.6.2.2 20 mm nominal outer dia .Pipes. 18.6.2.3 25 mm nominal outer dia Pipes. 18.6.2.4 32 mm nominal outer dia Pipes. 976 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work 18.7.1 15 mm nominal outer dia Pipes. 18.7.2 20 mm nominal outer dia .Pipes. 18.7.3 25 mm nominal outer dia Pipes. 18.7.4 32 mm nominal outer dia .Pipes. 18.7.5 40 mm nominal outer dia Pipes. 18.7.6 50 mm nominal outer dia .Pipes. 18.7.7 62.50 mm nominal inner dia Pipes. 18.7.8 75 mm nominal inner dia .Pipes. 18.7.9 100mm nominal inner dia .Pipes. 18.7.10 150 mm nominal inner dia Pipes. 977 18.8 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 18.8.1 Internal work - Exposed on wall 18.8.1.1 15 mm dia. nominal bore 18.8.1.2 20 mm dia. nominal bore 18.8.1.3 25 mm dia. nominal bore 18.8.1.4 32 mm dia. nominal bore 18.8.1.5 40 mm dia. nominal bore 18.8.1.6 50 mm dia. nominal bore 18.8.2 Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 18.8.2.1 15 mm dia nominal bore 18.8.2.2 20 mm dia nominal bore 18.8.3 External work : including trenching and refilling etc. 18.8.3.1 15 mm dia. nominal bore 18.8.3.2 20 mm dia. nominal bore 18.8.3.3 25 mm dia. nominal bore 18.8.3.4 32 mm dia. nominal bore 18.8.3.5 40 mm dia. nominal bore 18.8.3.6 50 mm dia. nominal bore 18.8.3.7 65 mm dia. nominal bore 18.8.3.8 80 mm dia. nominal bore 978 18.9 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment) 18.9.1 Internal work - Exposed on wall 18.9.1.1 15.88 mm outer diapipe 18.9. 1.2 22.22 mm outer diapipe 18.9.1.3 28.58 mm outer diapipe 18.9.1.4 34.00 mm outer dia Pipe 18.9.1.5 42.70 mm outer dia Pipe 18.9.1.6 48.60 mm outer dia Pipe 18.9.2 Internal work - Concealed Pipe 18.9.2.1 15.88 mm outer dia .Pipes. 18.9.2.2 22.22 mm Outer diaPipes 979 18.12 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.12.1 With C.I. wheel of approved quality (screwed end) 18.12.1.1 25 mm nominal bore 18.12.1.2 32 mm nominal bore. 18.12.1.3 40 mm nominal bore 18.12.1.4 50 mm nominal bore 18.12.1.5 65 mm nominal bore 18.12.1.6 80 mm nominal bore 18.12.2 With brass lever handle of approved quality. 18.12.2.1 25 mm nominal bore 18.12.2.2 32 mm nominal bore. 18.12.2.3 40 mm nominal bore 18.12.2.4 50 mm nominal bore 980 18.13 Providing and fixing CPVC gate valve with knob of approved quality. 18.13.1 25 mm nominal bore 18.13.2 32 mm nominal bore. 18.13.3 40 mm nominal bore 18.13.4 50 mm nominal bore 981 18.14 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.1 15 mm nominal bore 18.14.2 20 mm nominal bore 18.14 3 25 mm nominal bore 982 18.15 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1 Horizontal 18.15.1.2 Vertical 18.15.2 32 mm nominal bore 18.15.2.1 Horizontal 18.15.2.2 Vertical 18.15.3 40 mm nominal bore 18.15.3.1 Horizontal 18.15.3.2 Vertical 18.15.4 50 mm nominal bore 18.15.4.1 Horizontal 18.15.4.2 Vertical 18.15.5 65 mm nominal bore 18.15.5.1 Horizontal 18.15.5.2 Vertical 18.15.6 80 mm nominal bore 18.15.6.1 Horizontal 18.15.6.2 Vertical 983 18.16 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.16.1 15 mm nominal bore 18.16.2 20 mm nominal bore 18.16.3 25 mm nominal bore 984 18.17 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore 18.17.1.2 20 mm nominal bore 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore 18.17.2.2 20 mm nominal bore 985 18.18 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. 986 18.19 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design 18.19.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.19.2 With flyash bricks of 50 kg/cm2 strength 987 18.20 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.20.1 With common burnt clay bricks of 25 kg/cm2 compressive strength. 18.20.2 With flyash bricks of 50kg/cm2 strength. 988 18.21 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.21.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.21.2 With flyash bricks of 50kg/sqm compressive strength. 989 18.22 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 18.22.1 15 mm diameter pipe. 18.22.2 20 mm diameter pipe. 18.22.3 25 mm diameter pipe. 18.22.4 32 mm diameter pipe. 18.22.5 40 mm diameter pipe. 18.22.6 50 mm diameter pipe. 990 18.23 Repainting G.I. pipes and fittings with synthetic enamel white paint of approved quality : 18.23.1 15 mm diameter pipe. 18.23.2 20 mm diameter pipe. 18.23.3 25 mm diameter pipe 18.23.4 32 mm diameter pipe 18.23.5 40 mm diameter pipe 18.23.6 50 mm diameter pipe 991 18.24 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 18.24.1 15 mm diameter pipe 18.24.2 20 mm diameter pipe 18.24.3 25 mm diameter pipe 18.24.4 32 mm diameter pipe 18.24.5 40 mm diameter pipe 18.24.6 50 mm diameter pipe 18.24.7 65 mm diameter pipe 18.24.8 80 mm diameter pipe 992 18.25 Providing and filling sand all-round the G.I. pipes in external work. 18.25.1 15 mm diameter pipe 18.25.2 20 mm diameter pipe 18.25.3 25 mm diameter pipe 18.25.4 32 mm diameter pipe 18.25.5 40 mm diameter pipe 18.25.6 50 mm diameter pipe 18.25.7 65 mm diameter pipe 18.25.8 80 mm diameter pipe 993 18.26 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 18.26.1 15 mm nominal bore 18.26.2 20 mm nominal bore 18.26.3 25 mm nominal bore 18.26.4 32 mm nominal bore 18.26.5 40 mm nominal bore 18.26.6 50mm nominal bore 18.26.7 65mm nominal bore 18.26.8 80 mm nominal bore 994 18.27 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.1 15 mm nominal bore. 18.27.2 20 mm nominal bore. 18.27.3 25 mm nominal bore. 18.27.4 32 mm nominal bore. 18.27.5 40 mm nominal bore. 18.27.6 50 mm nominal bore. 18.27.7 65 mm nominal bore. 18.27.8 80 mm nominal bore. 995 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 996 18.29 Providing and fixing brass bib cock of approved quality 18.29.1 15 mm nominal bore 18.29.2 20 mm nominal bore 997 18.30 Providing and fixing brass stop cock of approved quality : 18.30.1 15 mm nominal bore 18.30.2 20 mm nominal bore 998 18.31 Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, and weighing not less then 400 kg, 15 mm nominal bore. 999 18.32 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. 1000 18.33 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore 1001 18.34 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. 1002 18.35 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore 1003 18.36 Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore. 1004 18.37 Providing and fixing C.P. brass pillar cock approved quality and make conforming to IS: specification. nd weighing not less than 650 gm,a15 mm nominal bore 125 mm long foam flow. 1005 18.38 Providing and fixing C.P. brass basin mixer of approved quality and make conforming to IS: specification.15 mm nominal bore. 1006 18.39 Providing and fixing C.P. brass wall mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1007 18.40 Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1008 18.41 Providing and fixing C.P. brass elbow operated bibcock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1009 18.42 Providing and fixing C.P. brass elbow operated pillar cock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1010 18.43 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.43.1 100 mm diameter 18.43.2 150 mm diameter 18.43.3 200 mm diameter 1011 18.44 Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore. 18.44.1 86 mm long weighing not less than 88 gm 18.44.2 122 mm long weighing not less than 99 gm 18.44.3 165mm long weighing not less than 110 gm 18.44.4 90mm long weighing not less than 93 gm 1012 18.45 Providing and fixing PTMT stop cock of approved quality and colour. 18.45.1 15 mm nominal bore, 86mm long. Weighing not less than 88 gms. 18.45.2 20mm nominal bore, 89mm long. Weighing not less than 88 gms. 18.45.3 Concealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms. 1013 18.46 Providing and fixing PTMT pillar cock of approved quality and colour. 18.46.1 15mm nominal bore, 107mm long. Weighing not less than 110 gms. 18.46.2 15mm nominal bore, 125mm long foam flow weighing not less than 120 gms. 1014 18.47 Providing and fixing PTMT, push cock of approved quality and colour. 18.47.1 15 mm nominal bore, 98mm long. Weighing not less than 75 gms. 18.47.2 15 mm nominal bore, 80mm long weighing not less than 46 gms. 1015 18.48 Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia. 18.48.1.2 125 mm nominal dia with 25 mm waste hole. 18.48.2 Rectangular type with openable circular lid. 18.48.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating. 1016 18.49 Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. 1017 18.50 Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40gms. 1018 18.51 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 18.51.1 15 mm nominal bore, 105 mm long. Weighing not less than 138 gms. 18.51.2 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 18.51.3 25 mm nominal bore, 152mm long. Weighing not less than 440 gms. 18.51.4 40mm nominal bore, 206mm long. Weighing not less than 690 gms. 18.51.5 50mm nominal bore, 242mm long. Weighing not less than 1240 gms. 1019 18.52 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour 15 mm nominal bore 18.52.1 30cm length. 18.52.2 45 cm length. 1020 18.53 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 18.53.1 15 mm nominal bore.Weighing not less than 32 gms. 18.53.2 20mm nominal bore.Weighing not less than 40gms. 18.53.3 25mm nominal bore.Weighing not less than 62 gms. 1021 18.54 Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 18.54.1 80 mm nominal bore 18.54.2 100 mm nominal bore 18.54.3 150 mm nominal bore 18.54.4 200 mm nominal bore 1022 18.55 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 18.55.1 80 mm nominal bore 18.55.2 100 mm nominal bore 18.55.3 150 mm nominal bore 18.55.4 200 mm nominal bore 1023 18.56 Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2compressive strength. 1024 18.57 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. 1025 18.58 Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1026 18.59 Making hole upto 20x20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including disposal of malba. 1027 18.60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.60.1 25 to 40 mm nominal bore 18.60.2 50 to 80 mm nominal bore 1028 18.61 Providing and fixing CP jet assembly to including connection etc complete. 1029 18.62 Providing and fixing ferro- cement water storage tank with cover, having minimum thickness of 10mm. The wall to be reinforced with two layers of double galvanized annealed square wooven wire mesh of 20 gauge wire spaced at 15mm for 300 litre capacity and 12mm for 450 to 2500 litres capacity finish with 3 layers of Cement mortar 1:2 duly modified with polymer based plastizers and hardening chemicals (Burogrout and Buroseal) The tank should conform to the specification prescribed by Structural Engineering Research Centre Roorkee/Gaziabad. The tanks to be painted with drinking water paint inside and aluminimum paint out side with provision of outlet, inlet, overflow and cleaning including hoisting and placing in position upto floor two level or 5 M. height. 1030 18.63 Add extra for additional floor lift beyond 5.0M.height. 1031 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.1.1 100 mm diameter 19.1.2 150 mm diameter 19.1.3 200 mm diameter 19.1.4 230 mm diameter 19.1.5 250 mm diameter 19.1.6 300 mm diameter 1032 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 19.2.1 100 mm diameter S.W. pipe 19.2.2 150 mm diameter S.W. pipe 19.2.3 200 mm diameter S.W. pipe 19.2.4 230 mm diameter S.W. pipe 19.2.5 250 mm diameter S.W. pipe 19.2.6 300 mm diameter S.W. pipe 1033 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design : 19.3.1 100 mm diameter S.W. pipe 19.3.2 150 mm diameter S.W. pipe 19.3.3 200 mm diameter S.W. pipe 19.3.4 230 mm diameter S.W. pipe 19.3.5 250 mm diameter S.W. pipe 19.3.6 300 mm diameter S.W. pipe 1034 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) 19.4.2 160 mm diameter OD (min. wall thickness 4.0mm) 19.4.3 200 mm diameter OD (min. wall thickness 4.9mm) 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) 1035 19.5 Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 19.5.1 110 mm diameter PVC. pipe 19.5.2 160 mm diameter PVC. pipe 19.5.3 200 mm diameter PVC. pipe 19.5.4 250 mm diameter PVC. pipe 19.5.5 300 mm diameter PVC pipe 1036 19.6 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) up to haunches of PVC. pipes including bed concrete as per standard design : 19.6.1 110 mm diameter PVC. pipe 19.6.2 160 mm diameter PVC. pipe 19.6.3 200 mm diameter PVC. pipe 19.6.4 250 mm diameter PVC. Pipe 19.6.5 300 mm diameter PVC pipe 1037 19.7 Providing and fixing square- mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks 19.7.1.2 With Sewer bricks conforming to IS : 4885 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks 19.7.2.2 With sewer bricks conforming to IS : 4885 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks 19.7.3.2 With Sewer bricks conforming to IS : 4885 1038 19.8 Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 19.8.1 100 mm dia. R.C.C. pipe 19.8.2 150 mm dia. R.C.C. pipe 19.8.3 250 mm dia. R.C.C. pipe 19.8.4 300 mm dia. R.C.C. pipe 19.8.5 450 mm dia. R.C.C. pipe 19.8.6 500 mm dia. R.C.C. pipe 19.8.7 600 mm dia. R.C.C. pipe 1039 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks 19.9.1.2 With Sewer bricks conforming to IS : 4885 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.1 With well burnt bricks 19.9.2.2 With Sewer bricks conforming to IS : 4885 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 19.9.3.1 With well burnt bricks 19.9.3.2 With Sewer bricks conforming to IS : 4885 1040 19.10 Extra for depth for manholes 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks 19.10.1.2 With Sewer bricks conforming to IS : 4885 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks 19.10.2.2 With Sewer bricks conforming to IS : 4885 1041 19.11 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 19.11.1 With well burnt bricks 19.11.2 With Sewer bricks conforming to IS : 4885 1042 19.12 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m 19.12.1 With well burnt bricks 19.12.2 With Sewer bricks conforming IS : 4885 1043 19.13 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) 19.13.1 With well burnt bricks 19.13.2 With Sewer bricks conforming IS : 4885 1044 19.14 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : 19.14.1 With well burnt bricks 19.14.2 With Sewer bricks conforming IS : 4885 1045 19.15 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design : 19.15.1 2.30m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.15.1.1 With well burnt bricks 19.15.1.2 With Sewer bricks conforming IS : 4885 1046 19.16 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : 19.16.1 With well burnt bricks 19.16.2 With Sewer bricks conforming IS : 4885 1047 19.17 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.17.1 With 20x20 mm square bar 19.17.2 With 20 mm diameter round bar 1048 19.18 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1049 19.19 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size): 19.19.1 With 20x20 mm square bar 19.19.2 With 20 mm diameter round bar 1050 19.20 Supplying and fixing C.I. cover without frame for manholes : 19.20.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. 19.20.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. 19.20.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg. 1051 19.21 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality 19.21.1 Light duty D- 2.5 19.21.1.1 Rectangular shape 600x450mm internal dimensions 19.21.1.2 Square shape 450mm internal dimensions 19.21.1.3 Circular shape 450mm internal diameter 19.21.2 Medium duty - 10 19.21.2.1 Square shape 450mm internal dimension 19.21.2.2 Circular shape 500mm internal diameter 19.21.3 Heavy duty D - 20 19.21.3.1 Circular shape 560 mm internal diameter 19.21.4 Extra Heavy Duty - 35 19.21.4.1 Circular shape 560 mm internal dia. 1052 19.22 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 1053 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 19.23.1 For pipes 100 to 230 mm diameter 19.23.2 For pipes 250 to 300 mm diameter 19.23.3 For pipes 350 to 450 mm diameter 1054 19.24 Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 19.24.1 100 mm dia. sand cast iron drop connection 19.24.2 150 mm dia. sand cast iron drop connection 1055 19.25 Extra for depths beyond 60 cm of sand cast iron drop connection complete : 19.25.1 For 100 mm dia. sand cast iron drop connection 19.25.2 For 150 mm dia. sand cast iron drop connection 1056 19.26 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) : 19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 19.26.2 Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10 19.26.3 Rectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 20 19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35 1057 19.27 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With well burnt bricks 19.27.2 With fly ash bricks 100 key/cm2 strangth 1058 19.28 Constructing brick masonry road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With well burnt bricks 19.28.2 With fly ash bricks 100 kg/cm2 strength 1059 19.29 Constructing brick masonry road gully chamber 110x50x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 19.29.1 With well burnt bricks 19.29.2 With fly ash bricks 100 kg/cm2 strength 1060 19.30 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.30.1 With well burnt bricks 1061 19.31 Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. 1062 19.32 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 sand) including testing of joints etc. complete : 19.32.1 100 mm dia 19.32.2 150 mm dia 1063 19.33 Providing, laying and jointing half round glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.33.1 100 mm dia 19.33.2 150 mm dia 19.33.3 200 mm dia 19.33.4 230 mm dia 19.33.5 250 mm dia 19.33.6 300 mm dia 1064 19.34 Providing and laying half round RCC pipes class (light duty) with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.34.1 100 mm dia. Half round R.C.C. pipe 19.34.2 150 mm dia. Half round R.C.C. pipe 19.34.3 250 mm dia. Half round R.C.C. pipe 19.34.4 300 mm dia. Half round R.C.C. pipe 1065 19.35.1 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.1.1 & 19.9.1.2 19.35.2 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.2.1 & 19.9.2.2 19.35.3 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.3.1 & 19.9.3.2 1066 19.36 Providing & Fixing of Precast RCC drain cover of size 600x 450 x70mm (thickness) with 4 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1067 19.37 Providing & Fixing of Precast RCC drain cover of size 750x600 x70mm (thickness) with 6 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1068 19.38 Providing & Fixing of Precast RCC drain cover of size 900x450 x90mm (thickness) with 8 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @ top face will have broom finish etc complete. 1069 19.39 Providing & Fixing of Precast RCC drain cover of size 1150x400 x100mm (thickness) with 10 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1070 19.40 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 900X450mm rectangular having weight of (complete unit) (weight of frame 11.7 kg + weight of cover 43.76kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1071 19.41 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 450X600mm rectangular having weight of (complete unit) (weight of frame 1.84kg + weight of cover 14.2kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1072 19.42 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 300X300mm (square) having weight of (complete unit) (weight of frame 1.12kg + weight of cover 4.1kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1073 19.43 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 600mm (round) having weight of (complete unit) (weight of frame 13.6kg + weight of cover 43.1kg + - 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5 mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1074 19.44 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 500mm (round) having weight of (complete unit) (weight of frame 11.2kg + weight of cover 41.78kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1075 19.45 Deduct for not providing and installing FRP/GRP manhole cover size 19.45.1 900mmx450mm (weight of cover 43.76kg ± 10%) 19.45.2 450mmx600mm (weight of cover 14.2kg ± 10%) 19.45.3 300mmx300mm (weight of cover 4.1kg ± 10%) 19.45.4 600mm (weight of cover 41.78kg ± 10%) 19.45.5 500mm (weight of cover 43.1kg ± 10%) 1076 19.46 Providind, laying and jointing HDPE Double Wall corrugated (DWC) pipes (excavation to be paid seperately) 19.46.1 100 mm dia to 110 mm dia 19.46.2 150 mm dia to 160 mm dia 19.46.3 200 mm dia 19.46.4 250 mm dia 19.46.5 300 mm dia 1077 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. 1078 21.2 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 21.2.2 Pre-laminated particle board with decorative lamination on both sides. 1079 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1080 21.4 Add extra for providing and fixing froasted glass instead of float glass 21.4.1 With glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.4.2 With glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.4.3 With glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1081 21.5 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge : 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness 21.5.2 With brass cover plate - minimum 1.25 mm thickness. 1082 21.6 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). 1083 21.7 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. 1084 21.8 Providing and fixing machine moulded aluminium covering of approved pattern and design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick and 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-Charge : 21.8.1 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 21.8.2 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) 1085 21.9 Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width 1086 21.10 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion & for shutters of doors, windows and ventilators 1087 21.11 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete. 1088 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and length as required with SS screws etc complete as per direction of Engineer-in-Charge. 21.12.1 Anodized (AC 15 ) aluminium tubular handle bar 21.12.2 Powder coated minimum thickness 50 micron aluminium tubular handle bar. 21.12.3 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar. 1089 21.13 Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1090 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). 1091 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. 21.15.1 Anodized (AC15) aluminium 21.15.2 Powder coated minimum thickness 50 micron aluminium. 21.15.3 Polyester powder coated minimum thickness 50 micron aluminium. 1092 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge 21.16.1 Anodized (AC15 ) aluminium 21.16.2 Powder coated minimum thickness 50 micron aluminium 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. 1093 21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. (Only weight of grill to be measured for payment). 1094 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately). 1095 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1096 21.20 Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1097 21.21 Providing and fixing 25 micron thick Non reflective heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in- charge of approved brand and make. 1098 21.22 Providing and fixing 12 mm thick toughened glass including all connectors and fixing accessories all complete for partitions, cubicals etc. As per direction of Engineer-in-Charge. 1099 21.24 Extra for froasted glass (with eching film) in item No. 21.22 1100 22.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge consisting of: (i)     Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course ( levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii)         2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportions. (iii)        Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (with 5 years service guarantee) Using rough Kota stone. 1101 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge (with 5 years service guarantee) Using rough Kota stone. 1102 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : a)   Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. b)   IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. c)    IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. d)      IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee) 1103 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete (with 5 years service guarantee) 22.4.1 Serrated with central bulb (225mm wide, 8- 11mm thick). 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick). 22.4.3 Kickers (320mm wide, 5mm thick). 1104 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a)  First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)  Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1105 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a)     After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b)    Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)   Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 1106 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a)  Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b)  Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: (with 5 years service guarantee) With average thickness of 120mm and minimum thickness at khurra as 65 mm. 1107 22.8 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic decimeter per square metre including preparation of surface but excluding grading complete with : (with five years service gurantee). Bitumen felt (hessian base) type 3 grade I conforming to IS: 1322. 1108 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). 1109 22.10 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6cu.dm per sqm including preparation of surface, excluding grading, complete. (With five years service gurantee). 1110 22.11 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blow or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee) 1111 22.12 Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm down size or pea sized gravel at 6 cudm per sqm. 1112 22.13 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. 1113 22.14 Grading roof for receiving water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) 22.14.3 Cement mortar 1:4 (1cement : 4 sand) 1114 22.15 Providing and laying insitu six course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm,conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. (with 5 years service guarantee) 1115 22.16 Providing and laying in situ four course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with 5 years service guarantee). 1116 22.17 Providing and laying in situ six course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with five years service gurantee). 1117 22.18 Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2mm thick water proofing membrane for corrugated roof sheets, black finished reinforced with glass fibre matt consisting in longitudinal and transverse direction at 23°C as 350/300 N/ 5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. (With five years service gurantee). 1118 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer of the membrane shall be as under:Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (with 5 years service guarantee) 1119 22.20 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee). 1120 22.21 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. [for item No. 22.18 to 22.20] 1121 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i)   Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii)     Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) 1122 22.23 Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. (i)Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc. (ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in V groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent. (iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs. (iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm. (v) Providing and applying 4th and 5th coat of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation (confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat. (vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 hrs (vii) Application of membrane coating shall be got done by authorized applicator of manufacturer. (viii) 5 years of service guarantee to be provided.All above operations to be done in order as per direction on Engineer-in-Charge. 1123 22.24 Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 & crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge. 1124 22.25 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and as per direction of Engineer-in-Charge. 1125 22.26 Providing and applying UV Stable polyurethane liquid water proofing membrane having Sun Reflectivity Index (SRI) of 106 on top of concrete roof / Retainning wall / Old layer of bituminous surfaces / Polyurethane foam and metal surfaces in three or more coats @20kg/ 10 sqm consisting of a coat of two component epoxy primer in ratio of 1:3(one part of resin and 3 parts of hardner) at a consumption of 2kg/10sqm. the vital physical and chemical parameters shall be as under : Min Elongation at break of 600% as per ASTM D412 and tensile strength of 3.0 N/mm2 as per ASTM D412. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and direction of Engineer-in-Charge. 1126 22.27 Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before casting of the base RCC slab. The pre-applied membrane gets bonded to the underneath of the poured concrete used as base slab. The membrane shall consist of a thick HDPE film, a highly aggressive pressure sensitive adhesive and weather resisting coating which bonds integrally to poured concrete of base slab. The membrane shall conforms to basement waterproofing protection to grades 2, 3 & 4 as defined in BS 8102:2009. The waterproofing membrane shall have following minimum properties: a)    Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385; b)      Puncture Resistance of 950 N (as per ASTM E154) c)      Elongation of >400 % (as per ASTM D412) d)    Peel Strength of concrete: >1500 N/m (as per ASTM D903) e)      Tensile strength of 28.2 MPA (as per ASTM D412). 1127 22.28 Providing and applying 2.0 mm thick twin colour flexible PVC waterproofing membrane. Flexibility under low temperatures as per EN 495-5 should be < - 20degC. On all horizontal surfaces Geotextile 300 Gsm to be laid over PCC, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane provide 300 Gsm Geotextile Then protection screed of suitable thickness. On all vertical surfaces Geotextile 300 Gsm to be laid along with Vertical wall, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane providing protection layer of Drain Board HDPE Dimple sheet before back filling of soil. 1128 22.29 Providing and applying waterproofing & Heat reflecting roof coating with 100% acrylic elastomeric polymers. Contains 30% Volume solid, tensile strength 8 kg/cm², crack bridging, VOC 30 ± 5 gm/ltr upto 2 mm. then applying two coats with forced coverage of 20 sqft/ltr/two coats. The operation shall be carried out after scrapping & propely clening the surface to remove loose particles with wire brush/Jet washer. Apply 1 coat @1 ltr/10 sqm & 3 undiluted coats @ 8 ltr/10 sqm with 4 hrs interval of each coat.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. 1129 22.30 Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer-in-Charge 1130 22.31 Providing & applying single pack component, solvent-free, cold applied, Polyurethane modified, elastomeric liquid applied waterproofing membrane- PU coat with excellent UV resistant capacity, The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film>350% with geotextile fleece =50% approx.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. The product performance shall carry guaranteed for 5 year against any leakage. 22.31.1 For Horizontal surface (with Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 22.31.2 For Horizontal surface (without Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 1131 22.32 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and Compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1132 22.33 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on positive side. The crystalline slurry shall be capable of self- healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.33.1 For vertical surface two coats @ 0.70 kg per sqm 22.33.2 For horizontal surface one coat @1.10 kg per sqm. 1133 22.34 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product Performance shall carry guarantee for 10 years against any leakage. 1134 22.35 Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge.The product performance shall carry guarantee for 10 years against any leakage. 22.35.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 22.35.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @ 0.070 kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar @ 0.040 kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole) 1135 22.36 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1136 22.37 Providing and applying waterproofing treatment in bathroom or tiled balcony area without breaking or removing tiles, by using waterproofing sheets as per manufacturers data sheet instructions. Permitting use of bathroom/balcony after 24 hours of application of treatement, Complete with materials and labour and gurantee of leakage for a period of 5 year. 1137 23.11 Providing and fixing 2 mm thick homogeneous conductive PVC (Poly Vinyl Flooring) EN (European Standard), total weight is 3250 g/m2, approx. PUR (Polyurethane Reinforced ), abrasion group P: ≤2.00 mm, residual indentation approx. 0.03 mm, anti-bacterial and fungal resistance, castor wheel test qualified, dimensional Phthalate free, directional in design.The floor finish should be termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto 100mm.Recommended to use in area like ICU , Post operative, Recovery rooms, OPD, Patient rooms, Corridors ,passages etc. 1138 23.12 Providing and fixing permanently static dissipative pressed homogeneous conductive PVC ( Poly Vinyl Flooring) EN (European Standard), anti static, wear layer thickness is 2mm (EN429), vinyl flooring having carbon backing with total weight 3000 g/m2 ESD approved, restorable properties, available in rolls. 100% recyclable (eco - freindly). Low VOC emission after 28days of installation (lower than ≤100μg/m3), Phthalate free non-directional in Design. Recommended to use in area like Operation theater, ICU, Server room, etc. 1139 23.13 Providing and fixing 0.92mm thick hetrogeneous compact PVC (Poly Vinyl Wall Covering) for Interior wall area, with wear layer thickness 0.12mm of PVC, EN(European Standard) total weight is 1500 g/m2, approx PUR (Polyurethane Reinforced), good resistance to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28 days of installation (lower than ≤10μg/m3), phthalate free, directional in design, The wall finish should termite free at the room perimeter. Recommended to use in area like OT,ICU, Corridors, Patient Room etc. 1140 23.14 Providing and fixing 1.3mm thick homogeneous PVC (Poly Vinyl Wall Covering) for interior area with wear layer thickness 1.3 mm of PVC, EN (European Standard) total weight is 2100 g/m2,approx. PUR (Polyurethane Reinforced), good resistant to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28days of installation (lower than ≤10μg/m3), phthalate free, directional in design.The wall finish should termite free at the room. Recommended to use in area like OT.ICU,Corridors, Passages , Patient Room Etc 1141 23.15 Supply and installation of 2mm thick homogeneous vinyl flooring, Highest abrasion wear rating Group T (EN660), binder content exceeds 55% of the flooring composition, no waste technology, consisting of PVC resin, plasticizers and stabilizers, type I. flooring ( (EN ISO 23997) max 0.4%, Abrasion group (MSZ EN 660-1) T, Fire resistance EN 13501-1 BF1-s1, Slip resistance DIN 51130 R9, EN 13893 DS, electrical resistance EN 1815 <2 kv, Chemical resistance EN ISO 26987, Castor chair resistance EN ISO 4918, Hygenie Bacterial resistant, Seaming method - hot welding, finishing complete . Recommended to use in area like Operation theater, ICU, Server room, etc. 1142 24.8 Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with self- drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. 1143 24.9 Providing and fixing thermal insulation with Resin Bonded glass wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by crisscrossing GI wire etc. complete as per directions of Engineer-in-Charge. 24.9.1 Providing and fixing insulation with resin bonded Glass wool 24.9.2 Providing and fixing insulation with resin bonded Rock wool 1144 24.11 Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsmlength upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1145 24.12 Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete : 24.12.1 Ridges plain (500 - 600mm). 24.12.2 Flashings/ Aprons.( Upto 600 mm) 24.12.3 North light curves. 24.12.4 Barge board (Upto 300 mm). 24.12.5 Crimp curve 24.12.6 Gutter. (600 mm over all girth). 1146 25.1 Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440x575x250 mm With integral foot rests. (Premium Range) 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410x515x255 mm with integral foot rests. (Premium Range) 1147 25.2 Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 1148 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380x520x375 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390x570x365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500x360 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360x500x330 mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) 1149 25.4 Providing and fixing white vitreous china Anti germ fluoro-polymer coated couple water closet flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete . 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420x710x810 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380x610x805 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375 x 650 x 800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 1150 25.5 Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370x695x795 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 395x710x730 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.3 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 385 x 720 x 710mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 360 x 640 x 685 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 1151 25.6 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet along with dual flushing cistern flushing capacity 3 & 6 litre approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 760X360X635mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 380x650x730 mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) 1152 25.7 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop cock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 1153 25.8 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.8.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 570x820x195 mm with wall mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x820x195 mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology). (Premium Range) 1154 25.9 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185 mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) 1155 25.10 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with 15 mm Table mounted single lever Tall boy basin mixture, (cartridge size 32 mm) 15mm quarter turn angular stop cock, 32 mm C. P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140 mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) 1156 25.11 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated urinal (Inbuilt spreaders, bottle trap and ceramic waste coupling) with 15mm brass pressmatic auto closing concealed urinal flush valve with wall flange (decol technology, 400000 operation warranted) i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) 25.11.2 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 475x315x715 mm. (Premium Range) 25.11.3 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 385x325x635 mm. (Premium Range) 1157 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock. (Premium Range) 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) 1158 25.13 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with 15mm Brass made pressmatic (Decol technology, 400000 operation warranted) concealed flushing Stop cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480x300x740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) 1159 25.14 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensor complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required. 25.14.1 White Vetrious China made Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) Size 340x325x650 mm with sensor (Premium Range) 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 7475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor for flushing. (Premium Range) 1160 25.15 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. (Premium Range) 1161 25.16 Providing & Fixing 8mm thick froasted Urinal glass partition size height 900 mm top width 450mm and bottom width 300mm brass made bracket with chrome plating. (Premium Range) 1162 25.17 Providing & Fixing plain bath tub of size 180x80x47cm body made of PMMA (Poly Methyl metha acrylate) with 20mm wooden reinforcement. (Premium Range) 1163 25.18 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range) 1164 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) 1165 25.20 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) 1166 25.21 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Concealed stop cock. (Premium Range) 1167 25.22 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) 1168 25.23 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 3-in1 Wall Mixer .(Premium Range Sanitary Ware) 1169 25.24 Providing and fixing in position best Indian C. P. brass made quarter turn (Ceramic disc Size 25mm) Flush Cock for Indian W. C. (Orissa Pan). (Premium Range) 1170 25.25 Providing and fixing in position best Indian single Lever Auto Mixing Wall Mixer (Cartridge Size 40mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1171 25.26 Providing and fixing in position best Indian single Lever Auto mixing Basin Mixer (Cartridge Size 32mm, nickel plating 0.10 micron and chrome plating 0.3 micron) For Wash Basin area use only. (Premium Range) 1172 25.27 Providing and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1173 25.28 Providing and fixing in position best Indian C. P. brass made Spout (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1174 25.29 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 300mm (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1175 25.30 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 450mm (nickel plating 0.10 micron and chrome plating 0.3 micron).(Premium Range Sanitary Ware) 1176 25.31 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 600mm (nickel plating 0.10 micron and chrome plating 0.3 micron) .(Premium Range Sanitary Ware) 1177 25.32 Providing and fixing in position best Indian shower rose 300x300mm square body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range Sanitary Ware) 1178 25.33 Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1179 25.34 Providing and fixing in position best Indian shower rose 200mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles .(Premium Range) 1180 25.35 Providing and fixing in position best Indian shower rose 240mm body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1181 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) 1182 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.20 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) 1183 25.38 Providing and fixing in position best Indian Auto Closing Pillar Cockdody with 65 mm extension (with DECOL cartridge) for wash basin use. (Premium Range) 1184 25.39 Providing and fixing in position best Indian Auto Closing Bib Cock with built in control cock wihh wall flange (with DECOL cartridge) for common area use. (Premium Range) 1185 25.40 Providing and fixing in position best Indian Auto Closing Urinal valve open type with built in control cock wihh wall flange (with DECOL cartridge) for urinal use only. (Premium Range) 1186 25.41 Providing and fixing in position best Indian Auto Closing Urinal valve concealed type (with DECOL cartridge) for urinal use only. (Premium Range) 1187 25.42 Providing and fixing in position best Indian Auto Closing wall mounted Pillar Cock (with DECOL cartridge) for wash basin use only. (Premium Range) 1188 25.43 Providing and fixing in position best Indian Auto Closing 40mm Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1189 25.44 Providing and fixing in position best Indian Auto Closing 40mm Dual Flow (3.0/6.0 liter) Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1190 25.45 Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) 1191 25.46 Providing and fixing in position best Indian Sensotronic Sensor Faucet for Wash Basin use only. (Premium Range) 1192 25.47 Providing and fixing in position best Indian Sensotronic Sensor battery & electrical oprated type (9V transformer) Faucet For Urinal use only. (Premium Range) 1193 25.48 Providing and fixing in position best Indian Sensotronic Sensor concealed type Faucet For Wall Mounted Water Closet use only. (Premium Range) 1194 25.49 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 300 mm long. (Premium Range) 1195 25.50 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) 1196 25.51 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Swivel Towel holder Twin Type. (Premium Range) 1197 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) 1198 25.53 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range) 1199 25.54 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dispenser with Metallic Bottle. (Premium Range) 1200 25.55 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Tumbler Holder. (Premium Range) 1201 25.56 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range) 1202 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) 1203 25.58 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Glass Self-size 600mm with toughened glass (Premium Range) 1204 25.59 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Double coat Hook. (Premium Range) 1205 25.60 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Towel Rake 600 mm. (Premium Range) 1206 25.61 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) W. C. Brush Holder. (Premium Range) 1207 25.62 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range) 1208 25.63 Wall Hung Basin: Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) 25.63.4 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 500x440x385 mm. (Premium Range) 25.63.5 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 635x485x305 mm. (Premium Range) 1209 25.64 Wall Hung Basin ; Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, 15 mm C. P. brass pillar cock, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 635x430x190 mm. (Premium Range) 1210 25.65 Providing and fixing in position best Indian, quarter turn table mounted sink mixer (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1211 25.66 Providing and fixing in position best Indian, quarter turn wall mounted sink cock (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1212 25.67 Shower Glass Cubical: Providing and fixing toughen glass shower enclosure conformed Is 2553 (part 1. 1990) or IS 14900. 2000 or IS 2835.1987 or IS 14450. 2000 with C. P. brass 5 Year warranted hardware, 19mm dia SS 304 grade stabilizer, all plastic Parts of food grade plastic and all glass shall be toughened at 700 degree Celsius and Anti lime scale treated including painting of fittings, cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.67.1 Providing and fixing corner entry 6 mm toughen glass made to measurement shower enclosure size 1200mm x1200mm x 1950mm with aluminum profile on sides, shower enclosure with door sliding on both sides. (Premium Range) 25.67.2 Providing and fixing 8 mm toughen glass wall to wall sliding shower enclosure with one fixed glass and one silding door with a Towel Rod Fixed on the fixed glass size Hight:2000 mm Width: 1500mm to 2000mm. (Premium Range) 25.67.3 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed withwall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1213 25.68 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed with wall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1214 25.69 providing and fixing white tempered glass showerpenal with special Surface body materials tempered glass with glass special surface PVC back. ABS Movable tops Shower, 4 moveable ABS body massage jets, Hand shower with fiexible hose,Brass Sout, shelf, Thermostatic mixer with diverter, 40 cm stainless steel braided hose, Minimum water pressure required 2 bar. 1215 25.70 Thermostat Mixer : Providing and fixing in position best Indian, concealed high flow bath and shower mixer with thermostatic control cartridge (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1216 25.71 Providing and fixing in position best Indian, exposed wall mounted bath and shower mixer with thermostatic control cartridge with button attachment on spout with connecting legs and wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) .(Premium Range) 1217 25.72 Providing and fixing in position best indian, eko exposed shower mixer (wall mounted) with thermostatic control cartridge, 115mm long bend pipe on lower side, connecting legs and wall flange (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1218 25.73 Providing and fixing in position best Indian, exposed shower mixer (tub mounted) with thermostatic control cartridge, with button attachment on spout with straight legs (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1219 25.74 Providing and fixing in position best Indian, 4 - way diverter consisting of concealed body and wall flange for multiple shower working with one shut-off position and 3 outlets for body shower, head shower and spout ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1220 25.75 Providing and fixing in position best Indian, thermostatic concealed high flow control valve with wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1221 25.76 Medical Faucets : Providing and fixing in position best indian, single lever surgical purpose elbow action basin mounted mixer with extended Operating lever without popup waste system with 450mm long braided hoses (cartage size32mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1222 25.77 Providing and fixing in position best Indian, surgical purpose elbow action pillar cock with extended Operating lever.( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) (Premium Range) 1223 25.78 Providing and fixing in position best Indian, surgical purpose elbow action wall mounted pillar cock with extended Operating lever and wall flange. (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1224 25.79 Providing and fixing in position best Indian, 692mm long, satin finish C. P. Brass grab bar made of 304 grade ss i/c all nuts and screw (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1225 25.80 Providing and fixing in position best Indian, satin finish, C. P. Brass grab bar with left/right 90 degree angle, made of 304 grade ss i/c all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1226 25.81 Providing and fixing in position best Indian, C. P. Brass grab bar vertical swing, 304 grade ss made all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1227 25.82 Providing and fixing 8mm thick frosted safety glass Urinal partition size 900mm height and 450mm width, fixed with C P brass bracket of appropriate size i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete.(Premium Range) 1228 27.4 Providing and fixing Stainless steel plate 304 grade of 1.50mm thick, including writing with Embossing of letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1229 27.5 Providing and fixing of name plate for offices name of Stainless steel plate 304 grade of 1.50mm thick, including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1230 27.6 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with 1.25m Chromium plated Steel Pipe 15mm dia, compete as per direction of Engineer-in-Charge. 1231 27.7 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer-in-Charge. 1232 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes welding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-in-Charge. 1233 27.10 Providing and fixing of prestressed vertically casted concrete panels (both surfaces should be smooth and having grooves on both faces) of M-40 grade of concrete of size 2100x300x50 mm having minimum 4 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed horizontally in full length of panel with prestressed precast concrete column of M-40 grade of size 3000x150x150 mm having minimum 7 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed vertically in full length to erect precast boundary wall panels to height 2100 mm from GL including excavation of pit of size 750x750x900 mm in all kind of soil except rock for erection of columns and grouting the pit with M-20 grade of concrete. Manufacturing, transportation and installation at site all complete as per the direction of Engineer-in-Charge. 1234 27.11 Extra for every additional height of 0.3 m up to height of wall 3 m 1235 28.35 Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. 1236 28.36 Providing and fixing of stone planter (bench) made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1200mm, width 500mm, legs height 500 mm. 1237 28.37 Providing and fixing of stone table made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1000mm, width 600mm, legs height 750 mm. 1238 28.38 Providing and laying C.C. pavement of mix M- 25 with ready mixed concrete from batching plant including centering and shuttering complete. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, with wire brush etc. complete as per specifications and directions of Engineer- in-Charge.Note: Cement content considered in this item is @ 330 kg/cum. 1239 29.1 Preparation of site plan and location plan with total station surveying showing all individual structures and features like trees, roads, culverts, nallas, electric poles, telephone poles, sewer lines, chambers, water supply lines, hand pumps, well etc. complete along with showing location of roads proposed in master plan. i/c Contours of entire area at 0.5 m. intervals using auto level, preparing of site plan in soft copy (using autocad) in suitable scale as desired by engineer-in-charge duly indicating north direction. Rate includes providing 1 digital copy and six hard copies, one print on tracing film, khasra map duly showing the land and location plan (index plan) and google image of the land. Rates are inclusive of transportation charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) 29. 1.1 Upto 1 Hectare 29.1.2 1 Hectare to 2 Hectare 29.1.3 Add extra for each additional one Hectare or part there off 29.1.4 Excavation of trial pit of size 1.20 m X 1.20 m with minimum depth of 0.9 m and maximum depth of 3.5m as directed by the Engineer in Charge. Trial pit shall be taken at suitable location/ locations as directed by Engineer in charge and shall be indicated on the site plan showing details of soil strata. 1240 29.2 Preparation of double line plan after measurement of internal as well as external dimensions of existing buildings/structures and plotting the same in suitable scale as directed by Engineer-in-charge. 1241 29.3 Preparing of double line plan for planning of addition and alteration work after measurement of internal as well as external dimensions and details of existing door window, ventilator openings and partitions, addition /alteration done previously in buildings/structures and plotting the same separately showing sectional elevations (minimum two numbers) and all elevations along with all relevant details like doors, windows stairs etc in suitable scale as directed by Engineer-in-charge. The consultant shall also submit detailed condition survey report. 1242 29.4 Performing Plate Load Test (P.L.T.) for Determining soil bearing capacity (SBC) at site including submission of Geotechnical Report and recommending bearing capacity in accordance with IS-1888-1982 (Without Conveyance). 1243 29.5 Performing Standard Penetration Test for determining soil bearing capacity (SBC) in accordance with IS-2131-1981 and submission of Geotechnical Report on bearing capacity based on SPT in accordance with IS-6403-1981 (Without Conveyance) 1244 29.6 Transportation charges for transportation of Geotechnical testing equipments for plate load test or standard penetration test upto a distance of 100km. (upto 100km going and 100km returning from district H.Q. both way) Rates are inclusive of Loading and unloading of testing equipments and other incidental charges during both journeys to be paid only once for one set (separate for PLT or SPT) of testing. 29.6.1 Up to 100km (both way) 29.6.2 Add extra for distance beyond 100km and upto 150km. (both way) 29.6.3 Add extra for every additional km beyond 150km (both way) 1245 29.7 Preparation of detailed estimate on the basis of the working drawing supplied by the department and current SOR applicable, including computation of bill of quantities (BOQ) of material and supplying the same in six hard copies and one soft copy to the Engineer-in-Charge and if required revision of the same without any additional charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) The estimate shall be prepared only in standard format prescribed as per appendix 14 of this SOR. 1246 29.8 Preparation of DPR including site visit to verify contours & soil reports and preparation of master plan of campus including architectural working drawings and estimates in prescribed format as per appendix 14 of this SOR to obtain AA; and there after architectural drawings for statutory approvals and detail drawings at construction stage; and as constructed drawings on completion of work the DPR. Bifurcation of professional fee payable in stages as per this item shall be in accordance with List-1, List-2 & List-3. Given in preambles of this chapter 3.All work such as preparation of DPR, working drawings, statuary drawings, details drawings and as constructed drawings shall be done by the same architect/consultant to ensure consistency in services, even if time required to complete all stages as per Activity sheet exceeds the contract period. 1247 29.9 Preparation of the structure design & drawings by a structural engineer empanelled with the Chief Architect MP PWD on the basis of architectural drawings supplied/approved by the department, in accordance with relevant codes/manuals and according to the Terms & Conditions, prescribed in Activity Sheet No-1, List-4 given in Annexure-14 appended with SOR. Design and drawing shall also include ‘Tables’ for the bar-bending schedules (BBS) and concrete/steel consumption. The design and drawing shall be submitted to the Engineer-in-Charge in six hard copies and one soft copy for execution. The payment shall be done in accordance with relevant stage in activity sheet and list. 29.9.1 First time design work 29.9.1.1 Built up area upto 500 sqm 29.9.1.2 Built up area more than 500 sqm and upto 3000 sqm 29.9.1.3 Built up area more than 3000 sqm. 29.9.2 Repetition of structural design of a structural design done by the structural himself or by any other structural engineer at different site, where S.B.C. or seismic zone is different.(only plinth area payment to be paid) 29.9.2.1 Plinth area upto 500 sqm 29.9.2.2 Plinth area more than 500 sqm and upto 3000 sqm 29.9.2.3 Plinth area more than 3000 sqm 1248 29.10 Assessment of load carrying capacity and structural soundness of existing building mainly comprising of R.C.C. structure using existing information such a existing drawing, design and footing details, if available. The consultant shall carry out destructive/non destructive testing of structure at site including site investigation which may require opening of footings by digging adjoining ground fill and restore backfill structure after testing is done. This work shall be performed by a structural engineer (proof checking) empanelled with the chief Architect MP PWD Bhopal or any government engineering college. The rate shall include all charges for labour, testing, consultation of geotechnical consultant and site visit to carry out site testing Per Sqm (built up area of wing/block of existing building where construction is proposed). 1249 29.11 Drafting structural drawing on the basis of the structural design supplied by the department in accordance with all relevant codes/manuals and as per IS: 1893- 2002 and IS: 13920-1993 with updation. The work shall include making revision/compliance if any and obtaining approval of drafting work, without any additional cost within time specified by the Engineer-in-Charge or from the competent authority. The drawings for approval shall be submitted to the Engineer- in- Charge in two hard copies (minimum size A-2) and there after fair drawings on 100 micron film along with seven copies of amonia prints (minimum size A-1) and one soft copy. Drawings shall be stamped and signed with the statement that Drafted by me as per structural design done or got done by the department. Note:- This work can be done only through a person having qualification of Diploma in civil engineering/BE (civil engineering) and having certificate in AutoCAD issued by AutoDesk or by its authorized institution.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
49.
Defence #9749428 AOC
Tender For Comprehensive Maintenance Amc Of Lift In Various Lab At M House Area Under Ge I Rnd Delhi; 1 comprehensive maintenance (Routine, preventive, periodical and breakdown) of Passenger/goods/service Lifts installed in following bldgs at METCALFE HOUSE Complex JCBareaas mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise through OEM by regularly examining, lubricating and adjusting the mechanical and electrical driving equipments/componentents, governor sleeve, shaft assembly, bearing/contact, governor jaws, car & hall mechanical push buttons, car & hall position indicators, car direction indicators, car and landing door drive/sensor and all other car and landing signal/ fixtures, deflectors, car and counter weight guide rails and bufferstravelling cable etc with and including replacement of defective / spares parts mentioned in BOQ/Sch - A as supply only and replacement of all kind of defective / spares parts other than mentioned in BOQ/Sch - A i.e. car/landing door sill, lift coil, lever bell crank, fuse holder, transformer, rack harness, guide shoe, light shield, any type of diode panel, push button assembly guide operator, kit door, bush bearing, copper contacts, line brakes, sight guard, any type of glass for hall button, emergency light, fireman control switch/ glass, announcement system, all type of safety, mounting sundrise, wire, lugs, nut, bolts, screws, lubricant, gear oil, aircord, landing wheel, aircord wheel, all types of control cards/logic cards, rewinding of motors(Main & Doors) etc and all machine works i.e. welding, cutting, drilling etc or any other parts/components which is not includ above as and when required to keeping the lifts in serviceable conditions round the clock (on all days including holidays) and during all weather/climate conditions to the entire satisfaction of Engineer-in-charge, complete all as directed for following Lifts. 2 Goods cumpassnger slift of capacity1500 KG with traveling speed of upto 1.0 mtrs/sec,(Ground +6 floors) installedOLD SAG LAB atM House including all instruments and controls complete all as specified and directed. (Make of Lift- Skylark). 3 Passenger lift of capacity 06 Passenger(408 Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground +5 floors) installed atOLD SAG LAB atMHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 4 Passnager lift of capacity20 passangers forwith traveling speed of upto 1.0 mtrs/sec, six floors (Ground + 5 floors) installed at SAG Lab at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- JOHNSON). 5 passnger lift of capacity08 passangers (544 KG) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 6 Passengerlift of capacity08 passangers (408 KG) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 7 Passanger lift of capacity05 passangers (408 Kgs) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `B Block Building ofMHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- Thyssen Krupp). 8 Passengerlift of capacity08 passangers with traveling speed of upto 1.0 mtrs/sec,(Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Schindler). 9 Passengerlift of capacity 08 passangerswith traveling speed of upto 1.0 mtrs/sec, (Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- Schindler). 10 Passenger lift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 11 Passengerlift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 12 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- OTIS). 13 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 14 Service lift of capacity200 KG for two floors (Ground + 1 Upper floor) with traveling speed of upto .5 mtrs/sec,through OEMinstalled at LASTEC wet canteen atMHouse including all instruments and controls complete all as specified and directed. (Make of Lift- JOHNSON) . 15 Passenger lift of capacity 10 Passenger with traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 16 Passengerlift of capacity10 Passenger G +4 FloorLiftwith traveling speed of upto 1.0 mtrs/sec, (Basement + Ground +3 floors) installed atJCB BLDG No-02 in MHouse including all instruments and controls complete all as specified and directed. .(Make of Lift- OTIS). 17 Goods cumpassengerLiftof capacity 1000 Kgswith traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- UTL). 18 Takingout existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 13 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc,complete all as specified and directed. 19 Taking out existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 10 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc complete all as specified and directed. 20 Taking down carefully existing old false ceiling with fan grill & LED up to 08 passenger lift from existing and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 21 Taking down carefully existing old false ceiling with fan grill & LED 13 passanger and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 22 Takingout existing old unserviceable control panelupto 08/13 passenger existing lift after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new control panal withmicroprocessor based AC variable voltage variable frequency (ACVVVF) drive close loop. The lift controller shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the controller. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The controller shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the controller for the purpose. The controller shall be complete with relay protection against the following:  Over current  Under voltage  Single phasing  Phase reversal  Earth leakage  Over voltage – 3Phase  Spikes & Surges Control panels & drive systems shall be designed to meet the requirements laid down by the EN12015 standards relevant to Electro-Magnetic Compatibility (EMC). Lift motor control system shall be electronic closed-loop control to ensure fail safe motor over speed controls and stopping accuracy of ± 3 mm to ± 5 mm. Load compensation circuits shall also be included to further improve upon the levelling accuracy. The levelling shall be ensured within ± 3 mm to ± 5 mm. An Automatic Phase reversal device shall be provided on the controller which shall be designed to protect the lift equipment against phase reversal and phase failure. The controller shall be designed to cut off the power supply, apply the brake and bring the car to a rest in the event of any of the above failures occurring. System should automatically restart when power is restored. System memory should be retained in the event of power failure or disturbance. Lifts should not go in to correction mode or correction run to the lowest floor / highest floor to update its position & memory. The controlled panel should be compatiable as per existing controlled system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before prorcurement for approval. 23 Takingout existing defective unserviceable main drive (any type) from existing control panel and supply & fixing new variable voltage, variable frequency drive (VVVF)upto 15 KW suitable for EXISTING LIFTand including making necessary electric connection, complete all as specified and directed. 24 Taking out old unserviceable Automatic rescue device (ARD)up to8/10/13 passenger lift with sealed maintenance free (SFM) batteries of 12 volts, up to 18 AH ( 06nos battery) after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new Automatic rescue device (ARD) . The ARD shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the ARD. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The ARD shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the ARD for the purpose. The ARD shall be complete with relay protection against the following:  Over current  Under voltage  Single phasing  Phase reversal  Earth leakage  Over voltage – 3Phase  Spikes & Surges. The ARD should be automatic evacuation to the nearest floor during power failure or other emergencies. All necessary wiring cable and Connectors connections for proper integration with the lifts control system. The ARD should be working correctly and integrating it with the lifts overall existing control system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before purcurment for approval. 25 Taking out existing old defective door sensor and supply & fixing new sensor with 3D INFRA RED safety edge with power unit on car door to safeguard passenger entering and leaving the liftsuitable for 08/10/13/20 passenger capacity lift complete all as specified and directed. 26 Taking out existing unserviceableground floorLOP up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 27 Taking out existing unserviceableTop floorLOP20 passenger cum goodsliftassembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 28 Taking out existing unserviceable LOP 1st foor tofifth floor up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 29 Taking out existing unserviceable COP8/10/13 passenger cum goods (G+)lift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating panel (COP) assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 30 Taking out existing unserviceable cabin fan and supply & fixing new cabin fan, non-oscilating type, axial flow, single speed, 250mm to 300mm sweep, 240 volt, with grill, complete all as specified and directed. 31 Taking out existing light fittings fromliftcabinand in lieu S & F New LED light fittings,complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 32 Taking out existing light fittings fromlift Shaft and in lieu S & F New LED light fittings, complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 33 Taking out existing old/ defective PVCflooring matand S & F NewantistaticPVC flooring 3mm thick flame resistance UV coating with superior qualityandthickness of mat 3 mm dully solution/adhesiveafter scraping ,cleaning surface preparing of old surface andcolour/design of mat shal be approved by Engr-in -chargea complete all as specified and directed . 34 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 07AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 35 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 12 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 36 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 18 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 37 Note : (For Serial No 01 to 20) The entire work mentioned in this BOQ/Sch - A. Item No. 1 to 17 including comprehensive, preventive and periodical maintenance of lifts / elevators shall be got executed through OEM or any reputed lifts manufacturer i.e. M/s Thyssen Krupp Elevator (India) / M/s OTIS Elevator India Pvt Ltd/ M/s Schindler (India) /M/s OTIS/M/s Johnson/M/s UTL, M/s Skylark only. The contractor shall upload / submit the scanned copy of MOU for AMC (inclusive of material) with lifts manufacturer, as mentioned above, item No. 1 under BOQ item ser for BOQitem No 1.01 to 1.16alongwith his application. The contractor shall also have to submit hard copy of MoU with his application.The lifts will be handed over to contractor in as and when condition and no claim in this effect will be accepted at any stage.The cost of all kind of replaced defective parts/spare /control cards/oil/ lubricants etc, other than mentioned in BOQ/Sch A, as and when required to making the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote thier rates accordingly. 38 The comnrehensive /preventive (periodical maintenance includes weekly fortnightly, monthly, quarterly, half yearly inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to Engineer-in-charge.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.All the complaint(s) will be addressed within 02 hrs from the time of receipt ofcomplaint. If, contractor or his tradesmen fails to attend the complaint within 02 hrs from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hr for first 04 hrs and after that Rs 1000 00(Rupees One Thousand Only) per complaint per hr shall be recovered from the contractors dues. The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect.All the complaints are required to be rectified within 24 hrs or within stipulated time given by the JE/Engineer-in-Charge, if, contractor of his tradesmen fails to rectify the defects, the compensation of Rs. 1000.00 (Rupees one thousand only) per complaint for each date (i.e. 24 hours) shall be recovered from the contractors dues. The decision of accepting officer is this regard shall be final and binding.
Contract Date: Mar 09, 2026 Contract Value : 35.71 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
50.
Agriculture #9749058 Technical Bid
Supply Of Tools, Instruments, Safety Equipment And Workshop Accessories To The Office Of The Assistant Executive Engineer (Agri), Wayanad , List Of Tools And Machineries , Tee Spanner Set Including Spanners Ranging From 8 Mm To 19 Mm Made From Chrome Vanadium Steel (Cr- V), Hardened And Tempered For Durability, The Handle Shall Be T-Shaped, Providing Maximum Torque And Grip And Surface Finish Shall Be Nickel-Chrome Plated For Corrosion Resistance. , Deep Socket Set Consist Of Sockets From 8 Mm To 22 Mm, Made Of Chrome Vanadium Steel, Fully Hardened, Tempered, And Chrome-Plated, The Sockets Shall Have Six-Point Or Twelve-Point Configurations For High Torque Applications, Suitable For Use With Ratchet Handles And Extension Bars. , Locking Plier (Vice Grip Type) 10 With Drop-Forged Steel Jaws With Heat-Treated Teeth For Firm Gripping, Include An Adjustable Screw And Quick-Release Lever, Nickel-Plated Surface For Corrosion Protection. , Long Nose Plier 6 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 6 Overall Length, With Insulated Handles. , Long Nose Plier 8 Made Of Forged Alloy Steel With Slim Tapered Jaws For Precision Gripping And Cutting In Confined Spaces, 8 Overall Length, With Insulated Handles. , Adjustable Pipe Wrench Suitable For Gripping Pipes Up To 75 Mm Diameter Made Of Cast Iron Body With Drop- Forged Steel Jaws, Serrated And Induction-Hardened And Handle Painted Or Powder-Coated. , Heavy-Duty Pipe Wrench With Jaw Opening Up To 110 Mm Made Of Forged Alloy Steel, Precision-Machined Teeth For Firm Grip, Designed For Mechanical And Plumbing Use. , Heavy-Duty Filter Wrench With High-Tensile Rubber Or Nylon Strap And Steel Handle For Removing Large Oil/Fuel Filters, Handle Length: Minimum 300 Mm. Suitable For Heavy Machinery Maintenance. , Medium-Duty Filter Wrench With Adjustable Steel Band And Handle, Suitable For Medium-Sized Oil Filters. Chrome-Plated Finish With Non-Slip Grip. , Soft Face Hammer With Dual Rubber Striking Faces To Prevent Surface Damage. Head Weight Approx. 300–500 Gm, Handle Made Of Fiberglass , Non-Marring Mallet Hammer With Rubber Or Plastic Head 40 Mm And Sturdy Handle. Head Weight Approx. 1 Kg. Suitable For Precision Fitting Without Metal Deformation. , Cold Chisels Made Of Chrome Vanadium Or Carbon Steel (18 Mm Dia Approax) , Hardened And Tempered To 58–60 Hrc. Size 25 Mm, Length 300 Mm, Approax Weight 500 Gm Ground Cutting Edge With Anti-Slip Striking End. , Steel Wedges, Hardened And Ground, Used For Splitting Or Aligning. Made Of Forged Alloy Steel With A Rust- Resistant Finish 230 Mm Length 1.5 Kg. , Adjustable Torque Wrench With Working Range 25–135 Nm. Drive Size 3/8 Or 1/2, Accuracy ±4% Of Indicated Value With Reversible Ratchet And Quick- Release Mechanism. , Heavy-Duty Adjustable Torque Wrench, Range 70–340 Nm. 1/2 Drive, Accuracy ±4%, Chrome Vanadium Construction With Calibration Certificate. , High-Capacity Torque Wrench, Range 135–540 Nm. 3/4 Drive, Accuracy ±4%, Knurled Handle For Non-Slip Grip, Supplied With Protective Case And Calibration Certificate. , Steel Scale Set (5 Nos) Made Of High-Quality Tempered Stainless Steel With Etched And Permanently Engraved Graduations In Both Metric (Mm/Cm) And Inch Units. Straight, With Accurately Ground Edges And Smooth Surfaces, Graduation Accuracy Shall Conform To Is 1481:1970 Or Equivalent. Lengths : 150 Mm, 300 Mm, 600 Mm, 450 Mm, 1000 Mm. Each Scale Shall Have Clear Visibility Markings And Corrosion-Resistant Satin Chrome Finish. , Vernier Calipers Made Of Stainless Steel, Precision- Ground And Finished, With A Measuring Range Of 0–200 Mm And Least Count 0.02 Mm / 0.001 Inch Capable Of Internal, External, Depth, And Step Measurements. Vernier Scale And Main Scale Markings Shall Be Clearly Etched For Long-Term Readability. The Instrument Shall Conform To Is 3651:1981 Or Din 862 Standards. A Locking Screw Shall Be Provided For Measurement Retention, And The Tool Shall Be Supplied In A Protective Case. , Outside Micrometer (0–25 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Outside Micrometer (25-50 Mm Range) Of Mechanical Analog Type, Conforming To Is 2967:1975 Or Din 863 Standards. The Frame Shall Be Rigid And Heat-Insulated, With Carbide-Tipped Measuring Faces, A Friction Thimble, And A Ratchet Stop For Consistent Measuring Pressure. The Least Count Shall Be 0.01 Mm, And The Thimble And Sleeve Shall Have Clearly Graduated Markings. The Micrometer Shall Be Supplied With A Setting Standard And Calibration Certificate. , Feeler Gauges Made Of Hardened And Tempered Spring Steel, Precision-Ground To Required Thickness, And Permanently Marked With Size Values. The Set Shall Include Multiple 75 Mm Long Blades Of 30 Different Thicknesses 0.03 Mm To 1.00 Mm Assembled In A Steel Holder With Pivot. Each Blade Shall Be Rust-Resistant And Polished For Smooth Operation. The Gauge Shall Conform To Is 3179:1982 Or Equivalent Standards. , Wire Gauge (Standard Bs 1505 Type) Manufactured From Hardened And Tempered Steel With Precisely Cut Slots For Wire Sizes 1 To 36 Swg. The Gauge Shall Be Circular Or Rectangular In Shape With Permanent Engraved Markings. The Tool Shall Comply With Bs 3737 / Is 3177 Standards For Accuracy. Surface Shall Be Satin Chrome Or Nickel Plated To Resist Corrosion Suitable For Measuring Diameters Of Wires, Rods, And Drill Bits. , Inside Calipers Shall Be Made Of Forged Steel Or Stainless Steel, Polished And Hardened. The Legs Shall Have Finely Ground Points With A Pivot Joint And Tension Adjustment For Smooth Movement. Measuring Range: 20–170 Mm Suitable For Measuring Internal Dimensions And Bore Diameters. Shall Conform To Is 3564:1985 Standards. , Outside Calipers Made Of High-Grade Carbon Or Stainless Steel With Hardened Tips, Spring Joint, And Knurled Adjustment Nut For Precision. Shall Conform To Is 3564:1985 Or Equivalent Standards. Surface Finish: Polished Or Chrome-Plated. 12 Inch Size , Centre Punch Manufactured As Per Is 7177 - 1999 Or Equivalent, Made Of High Carbon Or Alloy Tool Steel, Hardened And Tempered At The Striking End And Point. Length: Approximately 150 Mm, Approximate Weight 160 Gm With Point Angle Of 60° ± 2°. The Striking End Shall Be Chamfered To Prevent Mushrooming. Surface Finish Shall Be Black Oxide Or Polished. Suitable For Marking Centers On Metal Surfaces Before Drilling Operations. , Portable Digital Non-Contact Tachometer Of Reputed Make, With A Non-Contact Measuring Range Of Approximately 10 To 99,999 Rpm And Accuracy Not Inferior To ±0.04% ±2 Digits. Equipped With A Digital Lcd Display, Data Hold, Counting Function, And Computer/Usb Interface For Data Transfer, A Working Distance Of Around 0.2 M With A ±30° Working Angle, Reflective Tape, Interface Cable, And Carrying Case. Conforming To Iec 61010-1 / Is 13875. , Portable True-Rms Digital Multimeter Of High- Accuracy, Capable Of Measuring Ac/Dc Voltage Up To 1000 V, Ac/Dc Current Up To 10 A, Resistance, Capacitance, Frequency, Diode, And Continuity. The Meter Should Have Features Like Auto-Ranging, Data- Hold, Min/Max, And Relative Measurement Functions With A Large Back-Lit Display Of Minimum 4000 Counts Or Higher. The Instrument Shall Have Overload Protection, Fused Input Terminals, And Comply With Safety Category Cat Iii 1000 V Or Cat Iv 600 V As Per Iec 61010-1. The Unit Shall Be Housed In A Protective Insulated Casing Suitable For Field Use And Supplied Complete With Test Leads, Batteries, Protective Case, And Calibration Certificate. , Handheld Clamp Meter (True-Rms Type) Designed For Measurement Of Ac And Dc Currents Up To 1000 A, With Additional Functions For Ac/Dc Voltage, Resistance, Frequency, And Continuity. The Jaw Opening Shall Accommodate Conductors Up To 40–60 Mm In Diameter. The Meter Shall Feature A Large Digital Display, Auto-Range Selection, Data-Hold And Peak Capture Functions, And Have An Accuracy Of ±2 % Or Better. It Shall Meet Cat Iii 1000 V / Cat Iv 600 V Safety Standards, Include Overload And Transient Protection, And Be Built In A Shock-Resistant Insulated Body. The Clamp Meter Shall Be Supplied With Test Leads, Carrying Pouch, And Calibration Certificate. , Handheld Vibration Meter Shall Be Capable Of Measuring Vibration Velocity, Displacement, And Acceleration Within A Frequency Range Of 10 Hz To 1 Khz Or Higher Complying Iso 2954. The Instrument Shall Display Rms Or Peak Values In Standard Engineering Units (Mm/S, Μm, M/S²). It Shall Feature A Detachable Accelerometer Probe, Communicate With Pc Computer For Statistics And Printing By The Optional Cable And The Software. The Device Shall Be Compact, Battery-Operated, And Suitable For Predictive Maintenance Of Rotating Machinery. It Shall Be Supplied With Transducer, Magnetic Base, Extension Cable, And Carrying Case. , Wire Strippers Suitable For Removing Insulation From Copper Conductors Ranging From 0.5 Mm² To 6 Mm² , Ratchet-Type Crimping Tool Designed For Insulated And Non-Insulated Terminals 1.5 Mm² To 10 Mm², With Interchangeable Dies And Ergonomic Handles.Alloy Steel Duly Hardened & Tempered , Heavy-Duty Mechanical Or Ratchet Type Cable Cutters Suitable For Cutting Copper And Aluminium Cables Up To 300 Mm² , Soldering Iron Shall Be Of 40 W Capacity Insulated Handle. Cable Lugs And Ferrules Shall Be Of Tinned Copper, Crimp Type, Conforming To Din 46234/46235 Standards , Clamp-On Earth Leakage Meter Shall Measure Ac Leakage Current In Grounding And Neutral Conductors Without Disconnection, Within A Range Of 0.1 Ma To 100 A Or Higher. The Clamp Jaw Shall Accommodate Conductors Up To 50 Mm Diameter. The Instrument Shall Comply With Cat Iii 600 V Safety Category, Have A Back-Lit Display, And Be Supplied With Batteries, Manual, And Calibration Certificate. , Infrared Thermometer (Ir Gun) Shall Measure From - 50 °C To +550 °C With Laser Targeting And Digital Display. Should Have Rugged, Insulated Housings And Be Supplied With Charger, Carry Case, And Calibration Certificate. , Battery Load Tester (12V) Shall Provide Controlled Load Up To 2–200 Ah To Assess Battery Condition By Measuring Voltage Drop And Internal Resistance Instruments Shall Have Clear Displays, Polarity Protection, Insulated Clamps, And Rugged Enclosures For Workshop Use. , Digital Motor Checker Equipped With A Backlit Lcd Display, To Provide Accurate Measurements Of Key Electrical Parameters Including Insulation Resistance (0–200 M?) And Inductance (0–200 Mh), Operates On Alkaline Batteries, Featuring Low Battery Indication For Reliable Field Use, Precise Readings With An Accuracy Of ±2%. Complies With Iec 61010-1: Safety Requirements For Electrical Equipment For Measurement. , Smart Battery Charger Shall Provide Automatic Multi- Stage Charging For 12 V Batteries With Protections For Overcharge And Polarity Reversal. , Mechanical Puller (3?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 3 Inch (76.2 Mm), With A Spread Of Approximately 76 Mm, Reach Of About 65 Mm, And Working Diameter Range From 15 Mm To 80 Mm, Threaded Spindle Length 125 Mm, Conforming To Is 6149 / Iso 2985 Standards. , Mechanical Puller (8?, 2/3-Jaw, Double Ended) Of Reputed Make Made Of Hardened And Tempered Alloy Or Carbon Steel And Finished With Corrosion-Resistant Coating, With Interchangeable 2-Jaw And 3-Jaw Configuration, Allowing Both Internal And External Gripping Applications, Nominal Jaw Size Shall Be 8 Inch (203.2 Mm), With A Spread Of Approximately 203 Mm, Reach Of About 177 Mm, And Working Diameter Range From 30 Mm To 210 Mm, Threaded Spindle Length 174 Mm, Conforming To Is 6149 / Iso 2985 Standards. , T-Handle Spark Plug Socket Wrench (21 Mm) Carbon Steel With A Chrome-Plated Finish, With A 360- Degree Swivel Head For Flexible Operation, A Plastic Grip On The T-Handle, A Rubber Insert Within The Socket, An Approximate Weight Of 110 Grams, And Conforming To Relevant Standards For Hand Tools. , 10Pcs Carburetor Adjusting Tool Kit Including: 21- Teeth Splined, 7-Teeth Splined, Single D, Small Head Single D, Double D, Pac Man, Small Head Pac Ma,N Hexagon Shaped, Six Star, And Carburetor Cleaning Tools All Made Of High-Quality Stainless Steel Wear Resistant And Long Lasting With Ergonomic Handle Comfortable To Grip And Stable To Use. , The Heavy-Duty Spark Plug Cleaner And Tester Designed To Clean And Test Spark Plugs Under Simulated Engine Conditions, Operates On A 220 V Ac Supply And Incorporates A 12 V / 12 Kv Ignition Coil For Spark Generation And A 220 V / 12 V Electronic Vibrator For Cleaning Including A Pressurized Testing Chamber With A Working Pressure Of Up To 12 Kgf/Cm² And A Separate Abrasive Cleaning Chamber Equipped With A Double- Acting Valve For Blasting And Dust Removal, Should Be Compatible With Spark Plug Sizes M10, M12, M14, And M18 Through Interchangeable Rubber Adapters And Features A Pressure Regulator For Maintaining Safe And Consistent Operation. Product Should Conform To General Standards For Electrical Safety And Workshop Equipment, Such As Is 302 (Part 1): Safety Of Electrical Equipment, Is 10326: Automotive Service Equipment – Spark Plug Testers, Or Equivalent International Standards , Heavy-Duty Sprocket Chain Breaker And Splitter Tool Suitable For Breaking, Splitting, And Repairing Chains Of Size 420 To 530 Made Of High-Grade Carbon Steel , Compact Chain Saw Grinder For Precise Grinding Of Chain Saw Blades For A Rated Voltage Of 220–230 V At 50/60 Hz, With An Input Power Of 300 W And A No-Load Speed Of 8400 Rpm, Equipped With A 100 Mm Grinding Wheel Suitable For Most Standard Chain Saw Chains, Weighing Around 2.5 Kg, Conforming To General Safety And Performance Standards Such As Is 302 (Part 2/Sec 201): Electrical Safety For Hand-Held Tools And Iec 60745-2-4 , Soldering Station Operating On A 220–240 V Ac, 50/60 Hz Supply, Input Power Of 60 W, With A Preheat Time Of Approximately 1 Minute, Digital Temperature Display, Adjustable And Thermostatic Temperature Control Via A Rotary Knob, Built-In Ceramic Heating Element, A Straight Tip Head, A Durable Stand For Iron Placement, Packed In A Color Box, Conforms To Iec 60335-2-45: Household And Similar Electrical Appliances – Safety Of Portable Heating Tools And Iec 61340-5-1: Protection Of Electronic Devices . , Compact, Durable, And Easy To Operate Portable High- Pressure Hand-Operated Portable Grease Pump With A 10 Kg Grease Capacity And Delivers A Material Output Of Approximately 3 Grams Per Stroke, Maximum Block Pressure Of 140 Kg/Cm², A 2-Meter High-Pressure Rubber Hose Fitted With End Connections. , Corded Type Electric Impact Wrench Conforming To Is 7151:1983 / Iec 60745-2-2 [Vibration (=11.5 M/S²), And Noise (104 Db(A))], With A Continuous Input Rating Of 400 W,. It Shall Provide A Maximum Fastening Torque Of 350 N·M, With A No-Load Speed Of 2000 Rpm And Impact Rate Of 2000 Blows Per Minute, 12.7 Mm (½”) Square Drive, A 2.5 M Power Supply Cord. The Housing In Impact-Resistant Polymer With Reinforced Internal Metal Gear Casing, Suitable For Tightening And Loosening Ensuring Efficient Operation For Both Standard (M12–M22) And High-Strength Bolts (M12–M16) In Vehicle And Machinery Maintenance Applications , Electric Power Drill (Corded Type) Of Reputed Make, Single Phase 220–240 V, 50 Hz Ac Supply, 350 W And Variable Speed Range Up To 3000 Rpm (No Load). Including A Pistol-Grip Body, Keyed Or Keyless Chuck, And A 2.0 M Power Supply Cord Complying With Is 7554 / Iec 60745 / Iso 11148 Or Equivalent Standards, [Low Vibration (=3.0 M/S²) And Sound Pressure Level Below 80 Db(A)] Supplied Complete With Chuck Key, Side Handle (If Applicable), And Instruction Manual. , Portable Electric Heat Gun Powered By An 1800 W Motor Operating At 230 V Ac, For Adjustable Airflow Between 350–550 L/Min And A Working Temperature Range Of 60°C To 550°C, Selectable In Three Stages (60/350/550°C), Achieves Full Heat-Up Within 1 Minute, With A Heat-Resistant Plastic Body And Heat Isolation Cap, Weighs 750 G And Features A 2 M Cord Length And Conforming To Iec 60335-2-45: Household And Similar Electrical Appliances – Safety Of Portable Heating Tools And Iec 61000-3-11/12: Electromagnetic Compatibility Standards. , Bench Vice Of Heavy-Duty Engineer’S Type, Suitable For Fitting And General Workshop Applications With Jaw Width 125 Mm (5 Inches), With Replaceable Serrated Hardened Steel Jaws For A Firm Grip On Workpieces, The Body And Sliding Jaw Shall Be Made From High-Grade Cast Iron Or Forged Steel, Precision Machined To Ensure Smooth Operation And Alignment. The Vice Shall Be Equipped With A Large-Diameter Acme-Threaded Spindle And Steel Handle With Knurled Ends For Easy Tightening (1600 Kg Tightening Force) And Release. The Vice Includes A 360° Swivel Base With Locking Mechanism, Allowing Positioning And Adjustment As Required During Work. The Anvil Surface On The Rear Shall Be Machined And Hardened, Suitable For Light Hammering Operations. The Vice Shall Have A Clamping Capacity Of At Least 150 Mm, And All Moving Parts Shall Be Protected Against Rust And Corrosion By Paint Or Plating. The Bench Vice Should Be Suitable For Mounting On Heavy-Duty Wooden Or Steel Workbenches And Capable Of Withstanding Heavy Mechanical Use In Workshops And Maintenance Facilities. It Shall Conform To Is: 2586 (Specification For Bench Vices, Heavy Duty) Or Equivalent Standard. , Heavy-Duty Roller Tool Cabinet With 4 Drawers And One Cupboard Suitable For Use In Mechanical, Workshops For Organized Storage Of Hand Tools, Instruments, And Accessories Made Of High-Quality Cold- Rolled Steel Sheet With A Cabinet Body Thickness Of 0.8–1.0 Mm And Drawer Sheet Thickness Of 0.7 Mm, With An Overall Size Of 765 Mm (L) × 465 Mm (W) × 812 Mm (H) And An Overall Height Of 976 Mm Including Casters. Drawers Of Size 536 Mm (L) × 410 Mm (W) × 74.5 Mm (H), Mounted On Precision Ball-Bearing Slides And The Top Panel Area Should Be Suitable For Tool Placement During Maintenance Work. The Unit Should Be Mounted On Four Heavy-Duty Casters Of Size 5? × 2?, Two Of Which Shall Be Swivel Casters With Locking Brakes For Easy Mobility And Stability During Use. The Cabinet Shall Include A Central Locking System For All Drawers, Should Be Surface-Treated With Powder Coating For Corrosion Resistance And A Smooth Finish. The Tool Cabinet Shall Conform, Where Applicable, To The General Guidelines Of Is 7155 (Industrial Trolleys And Cabinets) And Iso 9001:2015 Quality Manufacturing Standards. , Oil Drain Pan Made Of High-Density Polyethylene (Hdpe) With A Capacity Of 16 Litres Including Integrated Handles, A Pouring Spout, And Anti-Spill Lips To Prevent Leakage During Draining Suitable For Chemical Resistance To Engine Oil, Transmission Fluids, And Coolants. , Rack For Batteries, Made Of Well-Seasoned Hardwood Or Marine Plywood With Sturdy Ms Frame Or Wooden Supports. Includes 3–4 Ventilated Shelves With Acid- Resistant Coating And Removable Rubber Or Pvc Mat. Designed To Hold Multiple Batteries Safely And Prevent Corrosion. Approx. Size: 1500 Mm × 1000 Mm × 450 Mm. , Rack For Spares Fabricated From High-Quality Wood Or Plywood With Ms Reinforcement. Includes Adjustable Or Fixed Shelves (3–5 Tiers), Each Supporting Up To 150 Kg (Udl). Finished With Protective Paint Or Polish For Workshop Use. Approx. Size: 2000 Mm × 900 Mm × 450 Mm. , Industrial Wet And Dry Type Vacuum Cleaner With A Power Rating Of 1500 W And Operating Voltage Of 220–240 V, 50 Hz, Suitable For Workshop And Service Bay Cleaning Applications With A Capacity Of 35 Litres, A Vacuum Suction Pressure Of 200 Mbar And An Airflow Rate Of 53 L/S, Ensuring High-Efficiency Dust And Liquid Removal. The Tank Should Be Made Of Corrosion- Resistant Stainless Steel (Minimum Ss 304 Grade) With Heavy-Duty Caster Wheels For Mobility. It Should Be Provided With A Flexible 5 M Power Cable, Washable Filters, Blower Function, And Accessories For Both Wet And Dry Operation. The Vacuum Cleaner Shall Conform To Iec 60335-2-69 (Safety For Wet And Dry Vacuum Cleaners For Commercial Use) Or Equivalent Indian Standard Is 11621:1986, And Include Overload And Thermal Protection Features For Motor Safety. , Portable, Electric-Operated Industrial Pressure Washer Conforming To Iec 60335-2-79 / Is 8442 With A Power Rating Of 1700 W (230 V, 50 Hz Single-Phase Supply) And A Maximum Working Pressure Of 130 Bar And A Flow Rate Of 7 Litres Per Minute, With Self-Priming Capability Of 0.5 M, High-Pressure Foam Detergent System, 6 M Pvc Hose, Manual Hose Reel, 5 M Power Cable, 3-In-1 Nozzle And Ergonomic Handle , Industrial Locker Cabinet (24-Door Type), Fabricated From 22-Gauge Mild Steel Sheet Pre-Treated And Powder-Coated For Corrosion Resistance And Smooth Finish With A Rigid Frame Structure, Each Locker Compartment With Individual Mechanical Key Locks Shall Measure Approximately 18 (D) × 12 (W) × 12 (H), With A Total Cabinet Size Of About 18 (D) × 48 (W) × 78 (H). A Load Capacity Of Minimum 10 Kg Including Ventilation Slots And Numbering Provision For Each Compartment , Abc Powder Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4 Kg Suitable For Class A Fires. Dry Chemical Powder (Mono Ammonium Phosphate) Based, Stored Pressure Type With Working Pressure Of 15 Bar, Suitable For Electrical And Combustible Material Fires.Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Co2 Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 4.5 Kg Suitable For Class B Fires . Carbon Dioxide Gas Type With Seamless High-Pressure Steel Cylinder Conforming To Is 7285, Discharge Hose With Horn, And Designed For Electrical And Flammable Liquid Fires. Extinguisher Sould Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory- Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Foam Type Fire Extinguishers, Is 15683:2018 Compliant, Portable Type With A Minimum Capacity Of 9 L, Suitable For Class C Fires. Stored Pressure Or Cartridge Type Using Aqueous Film-Forming Foam Suitable For Flammable Liquid Fires. Extinguisher Should Have Isi Certification, Pressure Gauge, Discharge Nozzle, Wall Mounting Brackets, And Color Coding As Per Is 2190. They Shall Be Factory-Filled, Tested At Twice Working Pressure, And Supplied With Inspection Tag And Instruction Label. , Fire Blanket Shall Be Made Of 840 Gsm Glass Fiber Or Kevlar-Coated Woven Fabric, Resistant To Temperatures Up To 550°C, Conforming To Is 11871 / Bs En 1869, And Provided In A Quick-Release Wall-Mount Case. Standard Blanket Size: 2.00 M × 1.00 M For Personnel Protection And Small Fire Suppression. , First Aid Box Of Size 32.5(H) X 28.5(W) X 8(D) Cmshall Conform To Is 13154 (Part 1–3), Made Of Powder-Coated Metal, Gi Or Abs Plastic, Waterproof And Corrosion Resistant, To Keep All Essential Medical Supplies For Industrial Workshops (Bandages, Antiseptics, Gauze, Adhesive Strips, Scissors, Burn Cream, Splints, Sterile Pads, And Cpr Mask). , Eye Wash Station Wall Mount Type, Made Of Stainless Steel Push Plate 12.7 Mm (1/2 Inch Bsp) Inlet, 4810 Ss, Providing Continuous Flow At 1.5 L/Min Per Outlet, Operated By A Push Plate, Complying With Ansi Z358.1 / Is 10592. , Foldable Stretcher Shall Be Lightweight Aluminum Or High-Tensile Steel Frame With Washable Canvas Sheet, Capable Of Carrying 120 Kg Load, Fitted With Safety Straps And Rubber Handles, Conforming To Is 1904 / En 1865. , Ppe: Helmets Hdpe Or Abs Shell, Is 2925 Compliant, Chin Strap, Sweatband, Impact-Resistant Up To 50 Joules. , Ppe: Goggles Polycarbonate Lenses, Anti-Scratch And Uv-Resistant, Is 5983 / En 166 Compliant, Side Shields. , Ppe Industrial Gloves: For Mechanical Work—Leather Or Nitrile (Is 6994); For Chemical Work—Pvc/Neoprene (En 374); For Electrical Insulation—Rubber Class 0 (Is 4770). , Ppe: Safety Boots Confirming To Is 15298 / En 20345 Compliant, Steel/Composite Toe Cap (200 J Impact), Oil- And Slip-Resistant Sole, Steel Mid Sole Antistatic. , Ppe: Protective Overalls With 100% Cotton 210 Gsm Or Fire-Retardant Fabric, Full-Sleeve, High-Visibility Reflective Tapes Per Is 15748 / En 20471. , Electrical Insulated Gloves Conforming To Is 4770 / Iec 60903, Suitable For Class 0 (1000 V Ac / 1500 V Dc) Electrical Protection, Made Of High-Dielectric Natural Rubber, Seamless, And Rolled Cuff Type. Each Glove Shall Undergo Routine Dielectric Test At 5 Kv For 1 Minute With No Puncture Or Flashover. The Gloves Shall Be Category Rc (Resistant To Acid, Oil, Ozone, And Low Temperature) And Provided With A Cotton Inner Liner And Storage Pouch. Supplied With Test Certificate Indicating Batch Number, Test Voltage, And Date. , Welding Face Shield Suitable For Full-Face Protection During Welding, Grinding, And Metal Fabrication Works With A Shield Size Of Approximately 9 X 12, Made Of Durable Polypropylene Providing High Impact, Heat, And Corrosion Resistance. The Face Shield Shall Include An Adjustable Ratchet-Type Headgear With Multiple Adjustment Positions To Ensure A Secure And Comfortable Fit For Prolonged Use. The Approximate Weight Shall Be 1.5 Kg Or Less, And The Product Shall Be Supplied As One Complete Unit. The Face Shield Should Conform To General Industrial Safety Standards Suitable For Use In Workshops. , Industrial-Grade Welding Gloves Suitable For Providing Protection, Comfort, And Dexterity During Welding, Cutting, And Metal Fabrication Operations, Made From Premium Split Leather (Cowhide Or Goatskin) With A Minimum Thickness Of 1.2 Mm, Offering High Resistance To Heat, Sparks, And Mechanical Abrasion. The Inner Lining Shall Be Made Of Soft Flame-Retardant Cotton Or Fleece, Providing Insulation Against Heat And Comfort For Prolonged Use. Each Glove Shall Have Reinforced Palm And Finger Patches For Added Durability And Better Grip While Handling Tools And Hot Metal Objects. The Gloves Should Be Stitched With Heat- Resistant Thread To Prevent Seam Failure During Exposure To High Temperatures. The Length Shall Not Be Less Than 14 Inches (350 Mm), Ensuring Full Hand And Wrist Protection, With Extended Cuffs To Safeguard The Lower Forearm Against Welding Spatter And Radiant Heat. The Gloves Should Be Conformed To En 388 (Mechanical Risks) And En 407 (Thermal Hazards) Or Equivalent Indian Standards (Is 6153). They Shall Be Suitable For Mig, Tig, Arc, And Gas Welding Operations. Should Be Heat And Flame-Resistant, Puncture And Tear-Resistant, And Designed For Repeated Use In Demanding Industrial , Heavy-Duty, Low-Profile Type Hydraulic Trolley Jack Suitable For Lifting Vehicles Or Machinery Up To A Rated Capacity Of 3 Tons. The Jack Shall Be Constructed From High-Grade Steel With Welded Frame For Superior Strength And Stability, A Lifting Range From Approximately 130 Mm To 465 Mm, Operated Through A Hydraulic Lifting Mechanism Actuated By A Detachable Pump Handle. Should Be Equipped With A Safety Overload Valve To Prevent Lifting Beyond Rated Capacity, And Precision Hydraulic Seals To Prevent Oil Leakage. The Unit Shall Feature A 360° Swivel Rear Caster And Wide Front Wheels For Easy Maneuverability. The Saddle Shall Be Grooved Or Rubber-Coated For Secure Load Contact. The Jack Shall Conform To Is 7620 / Asme- Pase Or Equivalent Standards, And Shall Be Finished With Corrosion-Resistant Powder Coating. Supplied Complete With Hydraulic Oil Filled And Ready For Use. , Industrial-Grade, Floor-Operated Type Hydraulic Trolley Jack Suitable For Lifting Heavy Vehicles, Machinery, Or Agricultural Equipment Up To A Maximum Capacity Of 5 Tons. The Construction Shall Be Of Robust, All-Steel Design With Reinforced Chassis And Welded Seams For Durability. It Shall Have A Lifting Range From Approximately 150 Mm To 500 Mm, Operated By A Long Detachable Handle Providing Sufficient Leverage For Smooth Lifting. The Hydraulic System Shall Incorporate A Safety Overload Bypass System, Precision Machined Piston And Pump For Consistent Performance, And A Reliable Lowering Control Valve For Controlled Descent. The Jack Shall Be Equipped With Steel Swivel Casters, Wide Stance For Stability, And A Saddle Plate With Anti- Slip Surface. The Surface Finish Shall Be Rust-Resistant Enamel Or Powder Coating. The Unit Shall Comply With Relevant Is/Ansi/Ce Safety Standards, Factory-Tested For Rated Load, And Supplied Ready For Workshop Service. , The Hydraulic Bottle Jack Of 10-Ton Rated Capacity, Suitable For Lifting Tractors, Vehicles, Or Heavy Structures. The Jack Body Shall Be Made Of High-Tensile Steel With Precision Machining For Durability And Stability. It Shall Have A Lifting Range From Approximately 200 Mm To 400 Mm, Incorporating A Screw Extension On The Ram For Height Adjustment. The Hydraulic System Shall Be Fitted With A Built-In Safety Overload Valve And High-Quality Seals To Prevent Leakage. The Operating Handle Shall Be Detachable And Designed For Easy Pumping Action. The Base Shall Be Wide And Stable To Ensure Safety During Lifting Operations. The Jack Shall Conform To Is 10672 / Asme B30.1 Or Equivalent Standards, And Finished With Corrosion-Resistant Paint. Supplied Fully Assembled, Tested, And Filled With Hydraulic Oil. , The Jack Stands Shall Be Of Heavy-Duty Ratchet Or Pin- Lock Type, Designed To Support Loads Up To 3 Tons Per Pair. Each Stand Shall Be Fabricated From High-Grade Steel With A Broad, Stable Base And A Ratcheting Support Column Providing Positive Load Engagement. The Height Adjustment Range Shall Be Approximately 290 Mm To 430 Mm, With Fine-Tooth Ratchet Mechanism Or Pin-Lock System Ensuring Secure Positioning. Each Stand Shall Include A Safety Locking Mechanism To Prevent Accidental Lowering Under Load. The Saddle Shall Have A Contoured Top For Stable Seating Under Vehicle Lifting Points. All Structural Components Shall Be Fully Welded And Finished With Corrosion-Resistant Powder Coating. The Stands Shall Meet Asme-Pase / Ansi Pald Or Equivalent Safety Standards. Supplied As A Matched Pair, Factory-Tested For Load Stability And Mechanical Integrity. , The Hydraulic Engine Hoist Shall Be A Foldable, Mobile Workshop Crane With A 2 Ton Rated Lifting Capacity, Suitable For Lifting, Removing, And Installing Vehicle Engines Or Heavy Assemblies. The Frame Shall Be Made Of High-Strength Steel Sections With A Reinforced Boom, Hydraulic Lifting Ram, And Heavy-Duty Castor Wheels For Mobility. The Boom Shall Have Adjustable Reach Positions (E.G., 500 Kg, 1000 Kg, 1500 Kg, 2000 Kg) With A Lifting Range Of Approximately 0 – 2300 Mm. The Hydraulic Ram Shall Be Operated Via A Detachable Handle And Equipped With A Safety Overload Valve To Prevent Overloading. The Hoist Shall Feature A Folding Design For Space-Saving Storage, And A 360° Swivel Hook With Safety Latch For Secure Load Handling. The Finish Shall Be Industrial Enamel Or Powder-Coated For Corrosion Protection. The Equipment Shall Comply With Is 7631 / Asme B30.20 / Ce Standards And Supplied Ready For Operation. , The Transmission Jack Shall Be A Hydraulic Telescopic Type Suitable For Removing And Installing Vehicle Transmissions Or Gearboxes From Underneath The Lift. The Rated Load Capacity Shall Be 0.5 Ton, With A Lifting Range Of Approximately 1100 Mm To 1900 Mm. The Lifting Mechanism Shall Be Actuated By A Foot-Operated Hydraulic Pump For Hands-Free Operation. The Tilting Head Plate Shall Provide Front, Rear, And Side Adjustment Through Fine-Thread Screws To Aid Alignment During Installation. The Base Shall Be Wide And Equipped With Four Swivel Castor Wheels For Stability And Maneuverability. The Unit Shall Have A Safety Overload Valve, Heavy-Duty Hydraulic Seals, And A Controlled Lowering Valve. It Shall Conform To Asme Pase / En 1494 Standards And Be Supplied Fully Assembled And Oil-Filled. , The Chain Block Shall Be A Manual, Hand-Operated Lifting Device Of 2 Ton Rated Capacity, Suitable For Workshop And Field Lifting Applications. It Shall Have A Mechanical Gear System Enclosed In A Steel Casing, Operating A Load Chain Made Of Grade 80 Alloy Steel With High Tensile Strength. The Standard Lift Height Shall Be 3 M – 6 M, With An Option For Extended Lift Lengths. The Mechanism Shall Incorporate A Load Brake With Dual Pawls For Positive Load Holding And Safety Hooks With Safety Latches At Both Ends. The Hand Chain Shall Run Smoothly On Precision-Machined Sprockets. The Unit Shall Conform To Is 3832 / Asme B30.16 / En 13157, With Load Testing Certificates And Corrosion- Resistant Paint Finish.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
TenderDetail
Loading tenders