View Bid Results For Aviation Equipment Tenders

We found 221 Bid Results related to aviation equipment tenders. You can find Contractor details who won aviation equipment tenders along with contract details in Bid awards announcements section.

Filters
Stage
193
19
9
Tender Publishing Platform
86
135
State / UT
31
47
31
15
10
9
8
7
7
7
6
6
6
5
5
5
5
5
4
4
4
4
3
3
3
2
2
2
2
2
1
1
Contract Value
50
58
83
30
Publish Date
0
0
0
0
0
Sector
19
76
33
25
22
19
7
7
6
5
4
4
3
3
2
1
1
1
1
1
Ownership
6
83
77
41
18
1
1
Within keyword
Active filters:
Showing 1–5 of 221 tenders matching your filters
1.
Civil Aviation #11360570 AOC
Bids Are invited for E1 - Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at Salem Airport comprising of LT Panels, DG Sets, CCR Panels, Runway Lighting, High Masts, Perimeter Lighting, Indoor and Outdoor Light Fittings, Power Points, Circuit/Submain Wiring, DBs, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signages etc., (As per Annexure-3 to 5 - List of Inventories ) on duty basis by deputing sufficient number of manpower as per Annexure-1 (8 Hours of Duty of Time as decided by Engineer-In-Charge), Monitoring, Control and General Maintenance for 100% Serviceability and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books (as per Annexure-6 to 20) and reporting as and when required, complete Upkeeping of the Installations etc., on all days as specified and as directed by Engineer-In-Charge as required. , E2 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For First Year (Terminal Building & technical Block (Make- Edwards, Model-IO-1000)) , E3 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For First Year (NDB Room (Make- Edwards, Model-IO-64)) , E4 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For Second Year (Terminal Building & technical Block (Make- Edwards, Model-IO-1000)) , E5 - Maintenance of Addressable Type Fire Alarm System (FAS) (by OEM/authorized dealer of OEM) including all Associated and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations (FAS), as specified and as directed by Engineer-In-Charge as required. For Second Year (NDB Room (Make- Edwards, Model-IO-64)) , E6 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (1.5 TR Wallmounted split AC) , E7 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (2 TR Wallmounted split AC) , E8 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (3 TR Tower type split AC) , E9 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For First Year (4 TR Cassette type split AC) , E10 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (1.5 TR Wallmounted split AC) , E11 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (2 TR Wallmounted split AC) , E12 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (3 TR Tower type split AC) , E13 - Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. For Second Year (4 TR Cassette type split AC) , E14 - CMC of 50LPH, 80 ltr tank capacity, Water dispensers of Normal, Cool and Hot mode with inbuilt RO & UV at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. First Year , E15 - CMC of 50LPH, 80 ltr tank capacity, Water dispensers of Normal, Cool and Hot mode with inbuilt RO & UV at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. Secound Year , E16 - Decorating the Airport Terminal building with LED Decorative serial light of 250 coils each coil of minimum 40 LED lamps, running design dispaly, running serial belt of 05 coils preferably in tri colour pattern on the occasion of Independence day / Republic day each time for 3 days including prefix & suffix to the actual day of function etc.as required. , E17 - Providing decorative illumination with multicolour LED colour wash flood light of minimum 10 nos for Independence day / Republic day with required cables and all accessories to illuminate the facia of the buildings each time for 3 days including prefix & suffix to the actual day of function etc.as required as directed by the Engineer -In- Charge. , E18 - Lifting of Submersible Pumps of various capacities from the existing Bore well/Well and reinstalling the Submersible Pumps in the existing bore well / well (After servicing / repairing both are exclusive) complete as required. , E19 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. Upto 3 HP , E20 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 5 to 6 HP , E21 - Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 10 HP , E22 - Repair & Rewinding of 1400 / 1200 mm Sweep Ceiling fan i/c replacement of spares as required. , E23 - Repair & Rewinding of all capacities of exhaust fan i/c replacement of spares as required. , E24 - Painting of electrical panels, CCR Panels, GLF Fixtures, DGs and street light poles etc., installations with two coats of synthetic enamel paint of approved shade quality and brand after applying two coats of redoxide i/c scrapping and cleaning, providing putty wherever required and inscription etc., as required. , E25 - Execution of items of schedule of rates CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/Terminal Building/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs.2,36,000/- (Inclusive of GST) in INR only and percentage above / below shall be calculated by AAI and paid accordingly. Note- The rate provided in DSR 2022 is inclusive of GST at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For First Year , E26 - Execution of items of schedule of rates CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/Terminal Building/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs. 2,36,000/- (Inclusive of GST) in INR only and percentage above / below shall be calculated by AAI and paid accordingly. Note- The rate provided in DSR 2022 is inclusive of GST at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For Second Year Total Quantity : 312
Contract Date: Ref. Documents Contract Value : 1.14 Crore
Boards / Undertakings / PSU No of Bidders 5
2.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 5.23 Lakh
Boards / Undertakings / PSU No of Bidders 3
West Bengal View Result →
4.
Educational and Research Institute #11134188 Technical Bid
structure waterproof and fire retardant international made hangar with aluminum structure having a span of 25 metres (as per onsite requirement) in width with waterproof and fire-retardant sheet (copy of certificate to be attached) should be strong enough to sustain high speed wind/rain pressure. wooden platform of 4”-9” height made with 19mm thick hard board and bed supported with providing 2”x2” wooden batons in properly leveled having no undulation, create no sound on using and covered with brand (*) new laminated carpet on complete area and 20 ceiling/pedestal fans covering the entire hangar structure. (entire ceiling and both walls from inside of both hangars should be covered with multi-colour cloth/fabric). 10 led metal lights & 50 mojo iron barricades (height 4 ft. x length 6ft.) with wheels should be provided one day before start of the book festival. auditorium (image at annexure-vi) fire retardant (certificate to be attached with tender document with validity) the flex/branding of the book festival may be affixed/provided on the hangar structures (image of hangar structure at page no. 44) as per the details given below: 1. branding on both sides of the hood (triangular shapes) of the hangar structures. 2. branding on the roof in hangar structures. 3. decoration of entry point of the structures with flowers/artificial flowers in consultation with festival/officer in-charge. the designs of the gates should be provided by the vendors for finalizing by the festival/officer in-charge. note: designs of all branding will be provided by nbt. *providing & laying on hire basis a brand new laminated carpet, non-woven needle punch carpet of genuine fiber minimum overall weight 1000 gm/ sgm (+ 5%) having minimum 3.90 mm thickness preferable containing 375 gm polyester fiber or equivalent fiber (+ 5%) and the carpet should not loss the thickness more than 25% after 1000 impact and of required shades & laying with approved adhesive or double side tape wherever required etc. as per the direction of officer-in-charge, i/c covering with polythene sheet till the inauguration of a festival. in case of dew factor, contractor should cover the entire structure of the hangars with waterproof tripal/polythene to avoid damaging of books. , stall: size 3m x 3m construction of stalls each of size 3x3mtr. with three side paneling of octonorm structure with computerized fascia of uniform colour (maximum 8 colour) with nbt logo in each and every stall on vinyl pasting in hindi/english (with flag numbering as per the image shown at annexure-v), consisting of 9 ms shelves of size 96”x8.5” with 2” depth duly powder coated in white colour, 9 led light (each of 9 watt), one octonorm table for counter of the same colour, two black cushioned chair with arms, a plug point for computer, two drinking water bottles (each of 1 ltr.) on daily basis, one small dustbin (10 ltr.) and one kanat of good quality of size 3mx3m size with provision of proper hanging system for covering/closing the stall after the book fair timings. the kanat should be made available to the participants a day before start of the book fair. laying & fixing of new brand laminated carpet(*) in the entire passage of indoor hall including the stall area, in case where structure is not required, should be provided by the contractor) , pagoda (3mtr.x3mtr.) construction of pagodas each of size 3x3mtr. on wooden platform, three side paneling of octonorm structure with computerized fascia of uniform colour (maximum 8 colour) with nbt logo in each and every pagodas on vinyl pasting in hindi/english with flag numbering as per the image shown at annexure-v in english/regional language of size 3m x3m, each with prefab octonorm system of the same colour in each stall, consisting of 9 ms shelves of size 96”x8.5” with 2” depth duly powder coated in white colour, 9 led light (each of 9 watt), one octonorm table for counter of the same colour, two black cushioned chair with arms, a plug point for computer, two drinking water bottles (each of 1 ltr.) on daily basis, one small dustbin (10 ltr.). 4mtr.x4mtr. polythene to cover the books is also required in each stall. , thematic customized gate: thematic/customized gate in line with the theme of the book fair with detailed specifications as shown and approved during digital presentation or as per designed provided by nbt. thematic gate comprises of backlit, wooden frame, mdf board. vinyl pasting and handmade painting (if required) with sufficient parco / led light. , stage: size 32’ x 20’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red color; • 1 table 20’ x 3’ with table cloth and frill in front or 10 center glass tables with side tables. • 1 lightening lamp • 15 executive wooden cushioned arm chairs with 10 side table of 3ft x 2ft size having vinyl pasting 4 side (design to be provided by nbt) • 10 standing ac tower (each of 5 ton) • 01 led screen wall (20’x8’) or as per stage requirement • 20 led parco light/ beam light (multi-colored on truss structure) for cultural events / programs & cultural • decoration of stage, entry gate & dais with fresh/artificial flowers should only be made after consulting the festival/officer in-charge • the arrangement of stairs with ramp with railings for support (both sides of stage) having vinyl pasting on 4 sides • 50 mineral water bottles (200 ml) for guests on stage, on per day basis • 10 name plates of the guests on stage as per the direction of the festival/officer in-charge. • 50 mojo barricades of 4ft. (height) x 6 ft. (width) with wheels • 2 podiums with nbt logo on sun board on three sides as per design provided by nbt 2 green room in the form of pagoda • size 6mtr.x6mtr. with three side covered with orange paneling, wooden platform with new brand laminated synthetic carpet. • 12 spot lights (9 watt each) • 4 led halogen lights (100 watt each) • 4 full length mirror with proper stand , complete pa system and stage set-up for organizing cultural / rock band programmes with operator for inaugural function and other programs along with provision of fusion and rock musical band playing for the 9 days during the book festival with two helper along with the provision of additional sound & lights as per tech rider of artists (as per the terms & conditions given at annexure-ix) a) box truss – aluminum box truss 60x40x25 with aviation grade material for safety and as per stage size (on all four sides) truss and scaffolding/speaker tower as required b). sharpy designing/pattern as per artist c) warm white led par d). blinder (4x4 motleys) e) colour led (54x3, 32x3) f). colour wash g) atomic strobe rgbw h) smoke machine high powered i) led percons j) avolite light controller/designing of lights patterns k) line array complete pa system venue suited dual, audio system (conical long throw system) – (lacoustic, jbl, dnb martin equivalent) l) bass audio subwoofer (lacoustic, jbl, dnb equivalent) m) side fill jbl, 835p n) foot monitors jbl 915 for stage angled curvature type for musicians o) 1x32 channel soundcraft mixer digital with presets and files (allen heath) p) amplifier audio digital with audio files for pa venue (crown, labgruppen, equivalent) q) amplifier crowns xti-6002 for stage r) di boxes bss/radial s) cordless mic sennheiser 945 for emeee t) shure mx series podium u) cordless shure for singer v) shure qlxd laple headset w) wired mirophones sm58 & sm57 for stage (shure/sennheiser) x) mic stand box big & small y) xlr snack long patch cord networking cabling console software laptop/playable engineer z) walkie talkie with talk back feature , announcement general pa system (digital) with 12 loudspeakers with 25–30-watt lmp and 1 standing mike (jbl/sony/phillips) for announcement purpose. , executive sofa sets (3 seater) with white covers along with 6 central tables , chairs with white cover for seat and back , wheel chair with attendant with proper uniform , queue manager , iron-ms steel barricades (size 4.5 ft. x 3 ft.) , brand new laminated carpet (*) for floor area (same specification as given for carpet in structure at s.no. 1) , tin wall covering with white color cloth with maximum height of 10 ft. , wooden platform with new laminated carpet , ground net (green) , fire fighting equipment (co2 water and powder mix with refilling dates) with one trained personnel with proper uniform for operating fire fighting equipment. , brand new dustbins (big size) plastic with cover , sweepers in proper uniform of the company for cleaning of ground are required one day before start of the book fair and till the end of the book fair (10:00 a.m. to 8:00 p.m.) , security personnel in proper security uniform and necessary equipments are required to be deployed at venue one day before start of the book fair and their after round clock till the end of the book fair: (*) rates may be given on per day basis only: a) supervisor b) guards , fresh painted steel almirah with lock and key (full size) , printing of flex & hoarding with mounting on iron frame in different locations (onsite/offsite), including gates, participants lists, backdrops, signages, etc. , vinyl digital print (3.3 ft. x 8 ft.) , pedestal / ceiling fans , wooden/steel tables 2’x5’ , selfie point on sunboard (5mm with digital vinyl print and mounting/framing) having heavy base (picture enclosed) – size: 4’x6’ and as per requirement , octonorm table for display of books , led wall screen of size 8’x12’ with masking & ramp (with operator) p5 – back support connectivity with multi cam setup, usb connectivity and laptop for insertion for av’s and tv’s, sound system and stage fold back speakers of 600 watts(2), sound mixing console and cables with wires and two power points (at the location decided by the officer-in-charge) for relay of live programme. , led screen (52 inch) — (the bazel 10m with stand and back support connectivity with multicam setup, usb connectivity and laptop for insertion for av’s & tv’s, sound system & stage fold back speakers, sound mixing console, cables with wires and 5 power points , providing of labours for routine miscellaneous work from 10:00 a.m. to 9:00 p.m. (rate may be given on per day basis) , halogen led lights of 150 watt with adjustable beam and angle complete with sufficient lighting and necessary wiring , 5 watt led coloured / decorative bulbs , silent generator set: the generator should be in operational condition one day before start of the book fair and till the conclusion of the fair. a) one 125 kva generator set (with fuel and operator) for full duration b) one 62 kva generator set (with fuel and operator) for full duration , main line connection for total job from electric and generator set sources and providing a line for connection inside the stalls of participants, illumination of main gate and toilet, area of the exhibition ground and any other area of the ground, if required with proper and sufficient supply. it shall be the duty of the contractor to get the temporary electric connection for the fair at his own cost one day before start of the book fair. the contractor shall arrange installation of the connection, tendering of security deposit etc., to government authorities at his own cost. only actual consumption charges will be reimbursed –to contractor by nbt on production of original bill by the contractor. in case of any problem for getting electric connection, it shall be the sole responsibility of the contractor to provide adequate supply through hiring more generators at his own cost one day before start of the book fair and no extra payment shall be given to contractor for hiring and providing such extra generator, if any. note : 1. providing power connection of various connected rating from switch board in various stands and with suitable size of cooper/aluminum 3½ /4 core armoured cable and earth wire controlled with suitable capacity switchgear such as ictpn, icspn/mcb i/c end termination laying of cable in floor, trench, carpets and tapping with power supply from permanent db of the ground i/c connections interconnection and maintenance during the fair period. (the cables and other wiring needs to be put under the wooden ramps/rubber covering mat etc. under the carpet on ground floor. 2. only one time payment as quoted by the tenderer will be made in case of any increase or decrease in number of stalls. , street light iron poles (20’x2-½’’) with 4 led halogen light each of 100 watt on each pole , photography per day basis (for 6 days) (photographs should be provided in the hard disk and pen drive after the book fair). 200 photographs of inauguration and other important programs are required in high resolution in coffee table album form in consultation with officer in-charge. • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications for 01 unit: dslr full frame hd 4k camera with 3 cameras with photographer with each camera for 6 days. • photography + cameras would be as per onsite requirement and as per the directions of the officer in-charge. , gimbal videography per day basis (for 6 days) (all programs should be provided in hd format and high resolution. the same should be provided in hard disk & pen drive after the book fair) along with 20 minute short documentary of the programs. • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications for 01 unit: 3 full hd video cameras setup with sdi output with 3 videographers with each camera for 6 days. • videography + cameras would be as per onsite requirement and as per the directions of the officer in-charge. note: provision of a professional digital video multi-camera setup for domestic book fairs, featuring broadcast-quality 1080p full hd (sdi format) production. the system includes: • three (3) full hd professional cameras with sdi output • online digital editing and production table • digital video mixer/switcher for live production • audio talkback communication system • professional audio mixer and sound equipment • on-site editing facilities • skilled technical crew, including camera operators and production personnel. this setup ensures high-quality live recording, switching, and editing suitable for professional broadcasting and online streaming requirements. , one drone camera with operator for videography of the event on day-to-day basis with on-site permission and security clearance (all coverages should be provided in hd format and high resolution. the same should be provided in hard disk & pen drive after the book fair). • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications: hd format and high resolution would be as per onsite requirement and as per the directions of the officer in-charge , live streaming on social media channels with social media team of 2 members (youtube & facebook) from two locations and on digital screens as per requirement , cctv cameras with live telecast on screen (led 52”) with complete installation with a control room access note: complete footage/recording for entire event must be provided after the event to nbt in hard drive & pen drive (rates may be given for full duration) , refreshment packets 250 each per day for children/students (each packet contains – one packet of good day biscuit, one packet of britannia fruit cake, one packet of lays chips & one packet of fruity/real juice/maaza/slice , hiring of taxi (swift dzire) minimum 80 km and 12 hours duty , hiring of taxi (innova) minimum 80 km and 12 hours duty , indian flag (khadi cloth) with mounting on pole (20 feet height) with 100 watt led (4 nos.) halogen light to be focused from bottom to top , acrylic words installation with wooden base covered with cloth , thematic installation / sculpture with complete set-up: each sculpture is to be made and placed on laminated printed carpeted platform (double plywood platform/wooden platform on iron frame with laminated carpet) at ideal height as per the size and design approved in the presentation and will consist the following items: i) 4-5 parco lights ii) cloth for masking the platform from all sides iii) 5-6 queue manager , lunch/dinner (veg. thaali) on per day basis during the book fair (rates may be quoted for one thali) , lunch/dinner (veg. thaali) on per day basis during the book fair (rates may be quoted for one thali)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
6.
Educational and Research Institute #11054746 Technical Bid
Tender for Structure Waterproof And Fire Retardant International Made Hangar With Aluminum Structure Having A Span Of 50 Metres (As Per Onsite Requirement) In Width With Waterproof And Fire-Retardant Sheet (Copy Of Certificate To Be Attached) Should Be Strong Enough To Sustain High Speed Wind/Rain Pressure. The Hangar Structure Should Cover Stalls (3X3 Mtr.) Having Passage Of 3 Mtr. (At Least) In Between The Line Of Stalls With Entry And Exit Gate. Wooden Platform Of 4-9 Height Made With 19Mm Thick Hard Board And Bed Supported With Providing 2X2 Wooden Batons In Properly Leveled Having No Undulation, Create No Sound On Using And Covered With Brand (*) New Laminated Carpet (Two Colour, One For Stall And Other Colour For Passage) On Complete Area And 150 Ceiling Fans Covering The Entire Hangar Structure. One Side Of Hangar Should Be Covered With Glass Wall / Transparent Sheet As Per Requirement (Entire Ceiling And Both Walls From Inside Of Both Hangars Should Be Covered With Multi-Colour Cloth/Fabric) And Entire Hangar Structure Should Be Surrounded By Tin Wall With Blue/White Cloth (Neat And Clean) Wall (4 Sides) In Addition To Truss. 10 Led Metal Lights & 50 Mojo Iron Barricades (Height 4 Ft. X Length 6Ft.) With Wheels Should Be Provided One Day Before Start Of The Book Festival. Auditorium (Image At Annexure-Vii) Fire Retardant (Certificate To Be Attached With Tender Document With Validity) The Flex/Branding Of The Book Festival May Be Affixed/Provided On The Hangar Structures (Stall Hangar Structure And Auditorium Hangar Structure As Per The Designs Mentioned At Page No.38-39) As Per The Details Given Below: 1. Branding On Both Sides Of The Hood (Triangular Shapes) Of All Hangar Structures. 2. Branding On The Roof Of Each Hangar Structures (30Mtr.X30mtr.). 3. Branding On Left And Right Panels Of Main Entry And Exit Point. 4. Branding On Pillar At The Main Entry. 5. Decoration Of Entry Point Of The Structures With Flowers/Artificial Flowers In Consultation With Festival/Officer In-Charge. The Designs Of The Gates Should Be Provided By The Vendors For Finalizing By The Festival/Officer In-Charge. Note: Designs Of All Branding Will Be Provided By Nbt. Note: All Branding Should Be On Iron Frame Except Roof Branding). Note: Two Hoardings Of Size 20X20 Will Also Be Required Before The Start Of The Book Festival. In Case The Auditorium Is Required To Be Constructed Outside The Hangar Structure, The Wooden Platform With Brand New Synthetic Laminated Carpet (As Per The Specification Mention Below) Is Also Required In The Auditorium. *Providing & Laying On Hire Basis A Brand New Laminated Carpet, Non-Woven Needle Punch Carpet Of Genuine Fiber Minimum Overall Weight 1000 Gm/ Sgm (+ 5%) Having Minimum 3.90 Mm Thickness Preferable Containing 375 Gm Polyester Fiber Or Equivalent Fiber (+ 5%) And The Carpet Should Not Loss The Thickness More Than 25% After 1000 Impact And Of Required Shades & Laying With Approved Adhesive Or Double Side Tape Wherever Required Etc. As Per The Direction Of Officer-In-Charge, I/C Covering With Polythene Sheet Till The Inauguration Of A Festival. In Case Of Dew Factor, Contractor Should Cover The Entire Structure Of The Hangars With Waterproof Tripal/Polythene To Avoid Damaging Of Books. Please Note: Apart From, The Entire Hangar Structures Along With All Stalls/Pagodas Should Be Covered With Fire Retardant/Prevention Solution Spray To Avoid Any Incident To Be Occurred Due To Fire. A Certificate Of The Authorized Agency(S) Of The Concerned State For The Above Work Is Also Required To Be Submitted To The Officer In-Charge Of The Festival A Day Before Start Of The Book Festival. , Stall: Size 3M X 3M: Stall Should Be Covered With Three Side Orange/Maroon Octonorm Paneling (Size 3.3 Ft. X 8 Ft.) With Computerized Vinyl Pasting Of Name Fascia In English & Hindi Language (With Flag Numbering As Per The Image Shown At Annexure-V), Each With Prefab Octonorm System Of The White Colour In Each Stall, Consisting Of 9 Ms Shelves Of Size 96X8.5 With 2 Depth Duly Powder Coated In White Colour, 9 Led Light (Each Of 9 Watts), One Octonorm Table For Counter Of The Same Colour, Two Black Cushioned Chair With Arms, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch, One Mayur Jug With Cold Water Facility (20 Ltr.) On Per Day Basis / 02 Litr. Drinking Water Bottle (Two) On Per Day Basis In Each Stall As Per The Direction Of The Officer In-Charge, One New Dustbin And One Dark Blue Curtain (Cotton Fabric) With Uniform Colour With Provision Of Fastening And Covering The Stalls Of Equivalent Size (3Mtrx3mtr = 9 Sqm). The Curtain Should Be Made Available To The Participants A Day Before Start Of The Book. 4Mtr.X4mtr. Polythene To Cover The Books Is Also Required In Each Stall. Laying & Fixing Of New Brand Laminated Carpet (*) In The Entire Passage Of Hangar Structure Including The Stall Area Should Be Provided By The Contractor , Kashmiri Hangar (AuthorS Corner): Following Items Will Be Required In AuthorS Corner: I) Stage: Size 24 X 20 X 2 In Height Made Of Wooden Platform With New Brand Laminated Synthetic Carpet (*) With Needle Punch Of Blue/Red Color. Ii) 50 Mineral Water Bottles (200 Ml) For Guests On Stage, On Per Day Basis. Iii) 1 Podiums With Nbt Logo On Sun Board On Three Sides As Per Design Provided By Nbt. Iv) 06 Executive Wooden Cushioned Arm Chairs With 03 Centre Glass Tables And Side Tables. V) 01 Led Screen Wall (8X12) Or As Per Stage Requirement Vi) 15 Ceiling Fan. , Pagoda (3Mtr.X3mtr.) Pagoda Structure On Wooden Platform With Covering Of Synthetic Needle Punch With New Laminated Carpet Of Good Quality Having Covered With Three Side Orange/Maroon Octonorm Paneling (Size: 3.3Ft. X 8 Ft.) With Computerized Vinyl Pasting Of Name Fascia In English & Hindi Language (With Flag Numbering As Per The Image Shown At Annexure-V Of Tender), Each With Prefab Octonorm System Of The White Colour In Each Stall, Consisting Of 9 Ms Shelves Of Size 96X8.5 With 2 Depth Duly Powder Coated In White Colour, 9 Led Light (Each Of 9 Watts), One Octonorm Table For Counter Of The Same Colour, Two Black Cushioned Chair With Arms, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch, One Mayur Jug With Cold Water Facility (20 Ltr.) On Per Day Basis / 02 Litr. Drinking Water Bottle (Two) On Per Day Basis In Each Stall As Per The Direction Of The Officer In-Charge, One New Dustbin And One Kanat Of Good Quality Of Size 3Mx3m Size With Provision Of Proper Hanging System For Covering/Closing The Stall After The Book Festival Timings. The Kanat Should Be Made Available To The Participants A Day Before Start Of The Book Festival. 4Mtr.X4mtr. Polythene To Cover The Books Is Also Required In Each Stall. Laying & Fixing Of New Brand Laminated Carpet (*) In The Entire Passage Of Hangar Structure Including The Stall Area Should Be Provided By The Contractor. , Canopy: Size: 3Mtr.X3mtr. With 3 Side Cover, Clear Height: 7 Feet, Full Height Till Dome: 10 Feet, Colour-White, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch And 1 Halogen Light Of 100 Watt, 4 Visitor Chairs And 1 Round Table (Top 4Ft.X4ft.) With Legs (Height 30 Inches) And Fascia Name. The Canopy Contains 3 Removable Side Walls, Can Install And Disassemble As Needed. , Thematic Customized Gate: Thematic/Customized Gate In Line With The Theme Of The Book Fair With Detailed Specifications As Shown And Approved During Digital Presentation Or As Per Designed Provided By Nbt. Thematic Gate Comprises Of Backlit, Wooden Frame, Mdf Board. Vinyl Pasting And Handmade Painting (If Required) With Sufficient Parco / Led Light. , Stage: Size 48 X 24 X 4 In Height Made Of Wooden Platform With New Brand Laminated Synthetic Carpet (*) With Needle Punch Of Blue/Red Color; • 1 Table 20 X 3 With Table Cloth And Frill In Front Or 10 Center Glass Tables With Side Tables. • 1 Lightening Lamp • 15 Executive Wooden Cushioned Arm Chairs With 10 Side Table Of 3Ft X 2Ft Size Having Vinyl Pasting 4 Side (Design To Be Provided By Nbt) • 10 Standing Ac Tower (Each Of 5 Ton) • 10 Ceiling Fan • 01 Led Screen Wall (40X12) Or As Per Stage Requirement • 20 Led Parco Light/ Beam Light (Multi-Colored On Truss Structure) For Cultural Events / Programs & Cultural • Decoration Of Stage, Entry Gate & Dais With Fresh/Artificial Flowers Should Only Be Made After Consulting The Festival/Officer In-Charge • The Arrangement Of Stairs With Ramp With Railings For Support (Both Sides Of Stage) Having Vinyl Pasting On 4 Sides • 100 Mineral Water Bottles (200 Ml) For Guests On Stage, On Per Day Basis • 20 Name Plates Of The Guests On Stage As Per The Direction Of The Festival/Officer In-Charge. • 50 Mojo Barricades Of 4Ft. (Height) X 6 Ft. (Width) With Wheels • 2 Podiums With Nbt Logo On Sun Board On Three Sides As Per Design Provided By Nbt 2 Green Room In The Form Of Pagoda • Size 6Mtr.X6mtr. With Three Side Covered With Orange Paneling, Wooden Platform With New Brand Laminated Synthetic Carpet. • 12 Spot Lights (9 Watt Each) • 4 Led Halogen Lights (100 Watt Each) 4 Full Length Mirror With Proper Stand Truss Structure From Main Gate To Main Stage With Decoration Of Multi-Colour Paper Streamer/Cloth On Passage Area With 3D Images Of Both Side Printed & Laminated Book Covers As Per The Design Shown At Annexure-Xi (Approx 1500 Sqmtr.) , Complete Pa System And Stage Set-Up For Organizing Cultural / Rock Band Programmes With Operator For Inaugural Function And Other Programs Along With Provision Of Fusion And Rock Musical Band Playing For The 9 Days During The Book Festival With Two Helper Along With The Provision Of Additional Sound & Lights As Per Tech Rider Of Artists (As Per The Terms & Conditions Given At Annexure-Viii) Box Truss - Aluminum Box Truss 60X40x25 With Aviation Grade Material For Safety And As Per Stage Size (On All Four Sides) Truss And Scaffolding/Speaker Tower As Required Sharpy Designing/Pattern As Per Artist Warm White Led Par Blinder (4X4 Motleys) Colour Led (54X3, 32X3) Colour Wash Atomic Strobe Rgbw Smoke Machine High Powered Led Percons Avolite Light Controller/Designing Of Lights Patterns Line Array Complete Pa System Venue Suited Dual, Audio System (Conical Long Throw System) - (Lacoustic, Jbl, Dnb Martin Equivalent) Bass Audio Subwoofer (Lacoustic, Jbl, Dnb Equivalent) Side Fill Jbl, 835P Foot Monitors Jbl 915 For Stage Angled Curvature Type For Musicians 1X32 Channel Soundcraft Mixer Digital With Presets And Files (Allen Heath) Amplifier Audio Digital With Audio Files For Pa Venue (Crown, Labgruppen, Equivalent) Amplifier Crowns Xti-6002 For Stage Di Boxes Bss/Radial Cordless Mic Sennheiser 945 For Emeee Shure Mx Series Podium Cordless Shure For Singer Shure Qlxd Laple Headset Wired Mirophones Sm58 & Sm57 For Stage (Shure/Sennheiser) Mic Stand Box Big & Small Xlr Snack Long Patch Cord Networking Cabling Console Software Laptop/Playable Engineer Walkie Talkie With Talk Back Feature , Foh Console 24 Channels (Yamaha/Avid S6l) With Required Connecting Cables For Equipment With 6 Cordless Mike (Along With Operator) , Announcement General Pa System (Digital) With 12 Loudspeakers With 25-30-Watt Lmp And 1 Standing Mike (Jbl/Sony/Phillips) For Announcement Purpose , Executive Sofa Sets (3-Seater) With White Cover And 1 Central Table , Executive Sofa Sets (2-Seater) With White Cover And 1 Central Table , Executive Sofa Sets (1-Seater) With White Cover And 1 Central Table , Chairs With White Cover For Seat And Back , Wheel Chair With Attendant With Proper Uniform , Queue Manager , Brand New Laminated Carpet (*) For Floor Area (Same Specification As Given For Carpet In Structure At S.No. 1) , Brand New Ribbed Laminated Carpet , Standing Air Conditioner (Tower) - 2.5 Ton , Wooden Platform (4 To 9 Height) With New Laminated Carpet , Iron Pole (Height 20) With 10 Led Lights Each Of 200 Watt To Be Fixed On Different Locations , Fire Fighting Equipment (Co₂ Water And Powder Mix With Refilling Dates) With One Trained Personnel With Proper Uniform For Operating Fire Fighting Equipment. , Brand New Dustbins (Big Size) Plastic With Cover , Supervisor With Sweepers For Cleaning Of Ground Are Required One Day Before Start Of The Book Festival And Till The End Of The Festival (10:00 A.M. To 8:00 P.M.) Supervisor Sweepers , Supervisor With Security Personnel In Proper Security Uniform And Necessary Equipments Are Required To Be Deployed At Venue One Day Before Start Of The Book Festival And Thereafter Round The Clock Till The End Of The Book Festival: Supervisor [Preferably Ex-Serviceman (Age Below 50 Years) Or Well Experienced Security Person Below The Age Of 45 Years] - Rates May Be Given For One Supervisor For 24 Hours Duty (For 10 Days) Guards (Well Experienced Security Person Below The Age Of 40 Years) - Rates May Be Given For One Guard For 24 Hours Duty (For 10 Days) , Fresh Painted Steel Almirah With Lock And Key (Big) , Fresh Painted Steel Almirah With Lock And Key (Small) , Flex Printing Without Framing & Mounting , Printing Of Flex & Hoarding With Mounting On Iron Frame In Different Locations (Onsite/Offsite), Including Gates, Participants Lists, Backdrops, Signages, Etc. , Vinyl Digital Print (3.3 Ft. X 8 Ft.) , Sunboard (5Mm) - As Per Requirement , Selfie Point On Sunboard (5Mm With Digital Vinyl Print And Mounting/Framing) Having Heavy Base (Picture Enclosed) - Size: 4X6 And As Per Requirement , Pedestal Fan/Ceiling Fan , Maroon Octonorm Panels/Walls (1Mtr.) With Frame (8 Ft. Height) , Orange Coloured Octonorm Panels/Walls (1Mtr.) With Frame (8 Ft. Height) , Led Spot Light (9 Watt) , Octonorm Table , Black Cushioned Chair , A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch , Dark Blue Curtain (Cotton Fabric) With Uniform Colour With Provision Of Fastening And Covering The Stalls Of Equivalent Size (3Mtrx3mtr = 9 Sqm) , Green Net , Tea/Coffee Vending Machine With Sugar/Milk/Tea/Disposable Medium Size Cup With Trained Operator For Preparing Tea/Coffee For The Guests During The Entire Period Of The Festival (300 Cup Per Day Basis) , Wooden/Steel Tables 2X5 With Frill , Pagoda (5Mtr.X5mtr.) With 2 Tables, 2 Chair, 2 Electric Points And 1 Halogen Light Of 100 Watt With Fascia Name , Pagoda (3Mtr.X3mtr.) With 1 Table, 2 Chair, 2 Electric Points And 1 Halogen Light Of 100 Watt With Fascia Name , Door With Proper Lock And Key System , Led Wall Screen Of Size 8X12 Or As Per Requirement With Masking & Ramp (With Operator) P5 - Back Support Connectivity With Multi Cam Setup, Usb Connectivity And Laptop For Insertion For AvS And TvS, Sound System And Stage Fold Back Speakers Of 600 Watts (2), Sound Mixing Console And Cables With Wires And Two Power Points (At The Location Decided By The Officer-In-Charge) For Relay Of Live Program. , Mojo Iron Barricades (Height 4 Ft. X Length 6Ft.) With Wheel - As Per Onsite Requirement/As Per Directions Of The Officer In-Charge , Led Tv (52 Inch) - (The Bazel 10M With Stand And Back Support Connectivity With Multi-Cam Setup, Usb Connectivity And Laptop For Insertion For AvS & TvS, Sound System & Stage Fold Back Speakers, Sound Mixing Console, Cables With Wires And 5 Power Points , Providing Of Labour For Routine Miscellaneous Work From 10:00 A.M. To 9:00 P.M. (Rate May Be Given On Per Day Basis) , Branded Desktop Computer System With Good Configuration (Core I5-4Th Processor/Ddr3 16Gb Ram/512Gb Ssd/Gt 730 4Th Gb Graphics/19 Inch Hd Led Monitor/Keyboard/Mouse/Window10/Wi-Fi , 3 In 1 Laser Printer With Cartridge, Scanner & Photocopier With A-4 Size Paper Ream (Hp/Canon) , Lease Line With Wi-Fi Internet Connection Having 500 Mbps With Proper Distribution At 10 Different Locations , Halogen Led Lights Of 200 Watt With Adjustable Beam And Angle Complete With Sufficient Lighting And Necessary Wiring , 5-Watt Led Colored / Decorative Bulbs , Tungsten Outdoor Warm Lighting For Decoration On Trees , Silent Generator Set: The Generator Should Be In Operational Condition One Day Before Start Of The Book Festival And Till The Conclusion Of The Festival. One 125 Kva Generator Set (With Fuel And Operator) For Full Duration One 62 Kva Generator Set (With Fuel And Operator) For Full Duration , Main Line Connection For Total Job From Electric And Generator Set Sources And Providing A Line For Connection Inside The Stalls Of Participants, Illumination Of Main Gate And Toilet, Area Of The Exhibition Ground And Any Other Area Of The Ground, If Required With Proper And Sufficient Supply. It Shall Be The Duty Of The Bidder To Get The Temporary Electric Connection For The Festival At His Own Cost One Day Before Start Of The Book Festival. The Bidder Shall Arrange Installation Of The Connection, Tendering Of Security Deposit Etc., To Government Authorities At His Own Construction Only Actual Consumption Charges Will Be Reimbursed To The Bidder By Nbt On Production Of Original Bill. In Case Of Any Problem For Getting Electric Connection, It Shall Be The Sole Responsibility Of The Bidder To Provide Adequate Supply Through Hiring More Generators At His Own Cost One Day Before Start Of The Book Festival And No Extra Payment Shall Be Given To Bidder For Hiring And Providing Such Extra Generator, If Any. Note : 1. Providing Power Connection Of Various Connected Rating From Switch Board In Various Stands And With Suitable Size Of Cooper/Aluminum 3½ /4 Core Armored Cable And Earth Wire Controlled With Suitable Capacity Switchgear Such As Ictpn, Icspn/Mcb I/C End Termination Laying Of Cable In Floor, Trench, Carpets And Tapping With Power Supply From Permanent Db Of The Ground I/C Connections Interconnection And Maintenance During The Festival Period. (The Cables And Other Wiring Need To Be Put Under The Wooden Ramps/Rubber Covering Mat Etc. Under The Carpet On Ground Floor. 2. Only One Time Payment As Quoted By The Tenderer Will Be Made In Case Of Any Increase Or Decrease In Number Of Stalls. , Street Light Iron Poles (20X2-½) , Photography For 10 Days (Photographs Should Be Provided In The Hard Disk And Pen Drive After The Book Festival). 200 Photographs Of Inauguration And Other Important Programs Are Required In High Resolution In Coffee Table Album Form In Consultation With Officer In-Charge. • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications For 01 Unit: Dslr Full Frame Hd 4K Camera With Minimum 3 Cameras With Photographer With Each Camera For 10 Days. • Photography + Cameras Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge. , Videography For 10 Days (All Programs Should Be Provided In Hd Format And High Resolution. The Same Should Be Provided In Hard Disk & Pen Drive After The Book Festival) Along With 20 Minute Short Documentary Of The Programs. • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications For 01 Unit: 3 Full Hd Video Cameras Setup With Minimum 3 Videographers With Each Camera For 10 Days. • Videography + Cameras Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge , One Drone Camera With Operator For Videography Of The Event On Day-To-Day Basis With On-Site Permission And Security Clearance (All Coverages Should Be Provided In Hd Format And High Resolution. The Same Should Be Provided In Hard Disk & Pen Drive After The Book Festival). • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications: Hd Format And High Resolution Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge , Live Streaming On Social Media Channels With Social Media Team Of 2 Members (Youtube & Facebook) , Cctv Cameras With Live Telecast On Screen (Led 52) With Complete Installation With A Control Room Access Note: Complete Footage/Recording For Entire Event Must Be Provided After The Event To Nbt In Hard Drive & Pen Drive (Rates May Be Given For Full Duration) , Hiring Of Taxi (Swift Dzire) Minimum 80 Km And 12 Hours Duty , Hiring Of Taxi (Innova) Minimum 80 Km And 12 Hours Duty , Digital Kiosk Of Latest Version (Android With Touch Screen) , Indian Flag (Khadi Cloth) With Mounting On Pole (20 Feet Height) With 100 Watt Led (4 Nos.) Halogen Light To Be Focused From Bottom To Top , Round Table (Top 4Ft.X4ft.) With Legs (Height 30 Inches) With Frill , Vvip Lounge Consisting Of The Following (Specification As Per Images Enclosed At Annexure Viii) - As Per Onsite Requirement/As Per Directions Of The Officer In-Charge: • Size - 90-100 Sq. Mtr. Or As Per Onsite Requirement • 3 Sofa Three Seater With White Cover/Cloth • 2 Sofa Two Seater With White Cover/Cloth • 5 Glass Central Table • 5 Dustbins, Each Of 20 Litre • Attached Washroom 6 X 16 (Western Washroom Fittings) • 10 Multi-Plug Points (With Four Points) For Computer With 20 annual periodical maintenance Socket With Switch • 20 Led Light • 4 Tower Air Conditioner 5 Ton (Each Cottage) • 10 Vip Chairs • 2 Big Almirahs • Photo Frame - 2 Ft. X 4 Ft. (Image Will Be Provided By Nbt) • 5 Pedestal Fans • 5 Ceiling Fans • 4 Insect Killer With Aluminium Body - Fly Catcher Machine (30 Watt) • Led Tv (52 Inch) - (The Bazel 10M With Stand And Back Support Connectivity With Multi-Cam Setup, Usb Connectivity And Laptop For Insertion For AvS & TvS, Sound System & Stage Fold Back Speakers, Sound Mixing Console, Cables With Wires And 5 Power Points For Relay Of Live Programme , Thematic Installation / Sculpture With Complete Set-Up: Each Sculpture Is To Be Made And Placed On Carpeted Platform (Wooden Platform & Carpet) At Ideal Height As Per The Size And Design Approved In The Presentation And Will Consist The Following Items: I) 4-5 Parco Lights Ii) Cloth For Masking The Platform From All Sides Iii) 5-6 Queue Manager , Acrylic Words Installation On Wooden Base Platform With Carpet , Lunch/Dinner (Veg. Thaali Containing Jeera Rice, Sabji, Dal, Chapati- 04, Raita/Curd, Paneer, Salad & Sweet Etc.) , Brand New Dustbins (120 Ltr ) Plastic With Cover As Per The Image Attached. , Pvc White Or Coloured Sky Advertising Balloon, 0.33 Mm, Size 15X15 Ft. (As Per Image Shown At Annexure-Xiii)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
7.
Health and Family Welfare #10834910 Price Bid
Tender For Supplying And Erecting Of 3M Height Designer Decorative Post Top Mounting Pole Made In Combination Of Galvnizing Pipe Which Is Fabricated Using 114M Dia X 3.0Mm Thick Base Section With Minimum Height Of 600Mm, The Middle Section Is Of 76Mm (+/-3%) Dia Gi Pipe With Height Of Section Is More Than 1350Mm And The Remaining Section Is Of 60Mm (+/- 3%) Dia Gi Pipe With Height Of Section Is More Than 1050Mm. The Complete Pole Shall Be Coated With Etch Primer And Further With Epoxy Zinc Phosphate Primer & Then Painted With Environmentally Stable Polyurethane Paint (Coating Thickness - 80 Microns Minimum). The Bottom And Middle Section Of The Pole Shall Be Provided With Decorative Cast Aluminium Embellishment To Add Aesthetic On The Pole As Shown In The Drawing. The Brackets Shall Be A Single Piece Assembly And Should Be Capable Of Orientation In Any Direction And Secured With Stainless Steel 304 Grade Hardware. The Pole Is To Be Provided With A Surface Mounting Suitable Base Plate Dia Of 350Mm And Suitable Thickness As Per Is Standards And Structural Reports. Decorative Ring Between Base Pole And Bracket Is Made Of Cast Aluminium Material. The Decorative Bottom Most Base Is Made Of Single Piece Cast Aluminium Material With 9W 30K Foot Light With (Ingress Protection) Ip66 Of Lamp Compartment. (All Al Casting Should Not Be In 2 Parts With Any Vertical Cuts Which Are Then Bolted Or Welded From Centre Which Spoils The Aesthetics Of The Designer Decorative Pole) With The Company / Brand Logo Embossed On It. All Dimension Is Within +/- 5% Tolerance. The Pole Should Be Provided With An Inbuilt Junction Box To Fix Four-Way Connector And 6A Mcb At The Bottom - The Inbuilt Box Should Have A Flush Door Of Suitable Size. The Decorative Pedestal To Be Mounted On A Suitable Size Steel Plate. The Mounting Plate Shall Be Provided With Elongated Holes For Alignment Of The Pole. The Suitable Size Foundation Bolt Shall Be Supply Along With The Pole Of En 8 Grade. The Manufacturer Needs To Provide A Structural Analysis For Structural Stability Of The Pole With The Relevant Is Standards Is 1239/1161/E250 Needs To Be Clearly Mentioned. The Same Needs To Be Confirmed In Form Of Test Certificates From The Manufacturer. The Manufacturer Should Have Valid Iso 9001:2015 From Ce Certification. Please Refer The Attached Drawing No - Cameroon 3M Sa Tm Pole. , Supplying And Erecting Of Decorative Luminaire Made Of Spun Aluminium Body With An Effective Heat Sink Design To Maintain The Operating Temperatures At Led Junction And Other Components Within Permissible Limits Corresponding To The Designated Design Life. The Luminaire Shall Be Provided With Highly Efficient Pc/Pmma Lens To Provide Uniform Photometric Distribution Suitable For Typical Streetlight Application And Facilitate Minimum Glare, With Degree Of Protection As Ip66 Lamp Compartment. The Luminaire Nabl 3Rd Party Report Needs To Be Attached For Ip66 And Ies File For Lighting Distribution From Goniometer And Lm79 Report From 3Rd Party Nabl. The Diffuser Shall Be Injection Moulded Polycarbonate With Ik Rating Of /=10 (With Attached Internal Ik Report From The Manufacturer) With A Diameter Of Not Less Than 285Mm And Height Not Less Than 86Mm To Maintain The Aesthetics Of The Product As Shown In The Drawing. The Design Of The Fixture Has To Be The Same Aesthetics As Shown In The Drawing. The System Ac Wattage Of The Luminaire Shall Be 30-40W (± 10%) With Mcpcb Of Not Less Than 1.6 Mm Thickness And Cu Of 35 Microns And 2.5 Thermal Conductivity For Fixture. Colour Temperature (Cct) Of 3000K, Colour Rendering Index Cri /= 70 And Residual Flux Of 70% (L70) @ 50,000 Hours At Ta Of 25°C. The Luminaire Shall Be Suitable For Operating Within Temperature Range From - 10°C To + 40°C. The Led Used Should Be High Power Leds (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) With Macadam /= 5. The Luminaire Should Be Deigned To Operate At Any Voltage From 140V To 280V, With Power Factor ≥ 0.95 And Shall Be Provided With Optional Built In Over Voltage And Under Voltage Protection And Internal Surge Protection Of 4/4 Kv In Both Common & Differential Modes And External Surge Protection Of 10 Kv, Electrical Class I. The Driver Arrangement Should Be Such That It Can Be Easily Maintained Without Opening The Ip66 Lamp Compartment. All The Mounting Hardware Shall Be Ss316 Grade For Better Life. The Luminaire Shall Comply With Safety Requirements Of Applicable Bis Standard. Overall Outer Dimensions Of Luminaire Shall Be Ø540Mm (±3%) And 975Mmh (±3%) Height And The Shape Shall Be As Per The Sketch Attached And Non-Responsive And Accordingly Rejected. Approved Makes: Schreder/Reytek/Ligman. Important: In Case The Bidder Proposes Alternate Make, It Would Be Necessary To Submit A Fully Functional Sample Of The Luminaire Along With The Bid Failing Which The Bid Will Be Considered And Non-Responsive And Rejected. The Luminaire Should Be Having A Warranty For A Period Of 5 Years Against Any Manufacturing Defects. The Manufacturer Should Have Valid Iso 9001:2015 From Ce Certification. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. Similar To Model No. Rigel Pt Clear Sl 30W Led 30K The Luminaire Should Be With A Valid Bis Number. , Supplying And Erecting Of Decorative Desing Bollard Of 0.6Mtr Height Decorative Bollard Made Of Steel Pipe Which Is Fabricated Using 114M Dia X 3.0Mm Thick. The Luminaire Should Be With High Pressure Die- Cast Thermal Management For Longer Life Of The Leds And The Ip65 Optical Compartment. The Diffuser Shall Be Optical Grade Clear Pc / Pmma Pipe. The System Ac Wattage Of The Luminaire Shall Be 9W (± 10%), Colour Rendering Index Cri /= 70 And Residual Flux Of 70% (L70) @ 50,000 Hours At Ta Of 25°C. Colour Temperature (Cct) Of 3000K. The Luminaire Shall Be Suitable For Operating Within Temperature Range From - 10°C To + 40°C. The Light Source Should Be (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) With Macadam /= 5. The Luminaire Should Be Deigned To Operate At Any Voltage From 140V To 280V, With Power Factor ≥ 0.95 And Shall Be Provided With Optional Built In Over Voltage And Under Voltage Protection And Internal Surge Protection Of 4/4 Kv In Both Common & Differential Modes. The Bollard Shall Be Provided With Decorative Die Cast Aluminium Embellishment To Add Aesthetic On The Bollard As Shown In The Drawing. The Bollard Is To Be Provided With A Surface Mounting Suitable Base Plate Of 200Mm X 200Mm X And Suitable Thickness As Per Is Standards. The Decorative Base Embellisment Is Made Of Cast Aluminium Material With Minimum Dia Of The Base Is 155Mm & Height Is 120Mm. All Dimension Is Within +/- 5% Tolerance. The Base Plate Shall Be Hot Dip Galvanized. The Mounting Plate Shall Be Provided With Round Holes For Alignment Of The Bollard. Overall Outer Dimensions Of Bollard Shall Be Ø130Mm (±3%) And 600Mm (±3%) Height And The Shape Shall Be As Per The Sketch Attached Herewith. Similar To Model No. Ara Ø130Mm Bp 600H Clear 9W Led 30K. , Supplying And Erecting Of Swimming Pool Light 18W Dc Operated With Drivers And All Accessories Cct -3000K/ Rgb Ingress Protection-Ip 68 With Ss Housing, High Power Led To Be Operated On Dc, In Order To Keep The Area Safe And Shock Proof. , Supplying & Erecting Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 6Kw, Tpn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cement Concrete Foundation. , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting And Marking Four Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A In Provided Distribution Board. , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Sp/Tp Mcbs Total 4 Ways /12 Poles, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 25 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 3 To 5M Octagonal / Conical Gi Pole). , Making Cement Concrete Foundation In 1:3:6 Cement Concrete, (20 To 25) Mm.Stone Metal Duly Plastered With Necessary Curing For Complete. (Pole Muffing Or Any Other Purpose). , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid Inprovided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70B50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Erecting 12.5 M (Clear Height) Motorized High-Mast (Top -150Mm, Bottom- 360Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen - 10025 S 355/E350 & 3Mm Thickness, With Base Plate 25 Mm Thick X Od 520 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Annual Rate Contract Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 5Mm, Sg-Dg U Clamps, Double Drum With Assembly 250 Kg, 5X2.5 Sq.Mm. Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete As Per Specification No. Ohpl/ Hm (Excluding Luminaries) , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High-Mast Of The Same Manufacturer With 32A Tpn Mcb Incomer, 24Hr Astronomical Time Switch With Minimum 5 Years Battery Backup, Ip 54 And Ik10 Protection, 25 A Tp Contactor For Automatic Switching Of Luminaires, 2 No. 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Complete Erected In Min. 14 Swg Crca Sheet Box With Supporting Angles, Self Lock, Gasket And Slanting Top Erected On Cement Concrete Foundation Complete. , Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 12.5 M Raising Lowering High Mast).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
9.
Educational and Research Institute #10680797 Price Bid
supply of tool machinery goods- 1 Connecting screw driver 2 Neon tester 3 Insulated combination pliers 4 Electrician knife 5 Soldering Iron Changeable bits 6 De- soldering pump 7 Soldering Iron 8 Optical Drives 9 Post error debugging card 10 PCI slot Testing tool 11 Network Management Software 12 Wireless Network Adapter 13 Router 14 LAN Cards 15 WI-FI LAN Card 16 Power Meter 17 Media Convertor 18 24 port UTP jack panel 19 NVR 20 POE adapters kit 21 IP Camera Outdoor 22 Analog camera with dvr 23 SMPS 24 Blu-Ray driveand player Dell/ hp/ toshiba 25 Digital Camera 26 Network storage 27 Card Reader 28 SMPS Trainer kit 29 Foot rule steel tape 30 Steel Measuring Scale 31 MARKING KNIFE 32 Try Square 33 Bevel Square 34 Carpenter marking gauge 35 Carpenter mortise gauge 36 Hand Saw 37 Metal smoothing plane Anant 38 Screw driver 39 Contraction measuring scale 40 Wi Fi Router 41 Switch 42 DVD or Blu-Ray Writer 43 Network Rack 44 Screw Driver Set 45 Mini Dongle for Bluetooth devicesConnection 46 Patch Panel 47 Punching Tool 48 Tally 49 Box drawing instrument 50 Protractor celluloid 51 Scales plotting box wood 6 metric scales 52 Set square transparent 53 Set square celluloid 54 T-Square 55 Template- Architects and builders 56 Telescopic Alidade 57 Levelling staff straight pieces 58 Transit Theodolite with stand with all accessories 59 Digital theodolite 60 Instrument for total station 61 DLP projector 62 First aid box 63 Screen for projector 64 Air conditioner 65 Document Camera Visualiser 66 Smart board-inter active board 67 Measuring Steel Tape 68 Combination Plier Insulated 69 Screw Driver Insulated 6mm X 150 mm 70 Electrician screw driver thin stem insulated handle 4mm X 100 mm 71 Heavy Duty Screw Driver insulated 72 Electrician Screw Driver thin stem insulated handle 73 Punch Centre 74 Knife Double Bladed Electrician 75 Neon Tester 76 Steel Rule Graduated both in Metric and English Unit 77 Hammer cross peen with handle 78 Connecting screwdriver 79 Neon tester 500 V. 80 Screw Driver Set 81 Soldering iron 82 Electrician knife 83 Tweezers 84 Digital Multimeter 85 Soldering Iron Changeable bits 86 De- soldering pump electrical heated manual operators 87 Precision set of screw drivers 88 Precision set of screw drivers 89 Precision set of screw drivers 90 Tweezers Bend tip 91 Steel measuring tape 92 Tools maker vice 93 Crimping tool pliers 94 Magneto spanner set 95 File flat second cut 96 File flat smooth 97 Plier - Flat Nose 98 Round Nose pliers 99 Hammer ball pen 100 Allen key set Hexagonal set of9 101 Tubular box spanner set of 6Nos 102 Magnifying lenses 103 Continuity tester 104 Hacksaw frame adjustable 105 Chisel Cold Flat 106 Hand Drill Machine Electric with Hammer Action 107 Bench Vice 108 Bench Vice 50 mm 109 DC Regulated Variable Programmable DC Power Supply 110 LCR meter Digital Handheld 111 Analog multimeter 112 Clamp meter 113 Dimmer starter 114 Autotransformer 115 Milli Ammeter AC 116 Op Amp trainer 117 Digital IC Trainer 118 Digital IC Tester 119 Digital and Analog Bread Board Trainer 120 POWER ELECTRONICS TRAINER with at least 6 nos of onboard applications 121 Electronic circuit simulation software with 6 user licenses 122 Different types of electronic and electrical cables connectors sockets terminations. 123 DSO colour 124 PAM PPM PWM trainer kit 125 AMFM Commercial radio receivers 126 Sensor trainer kit containing Various sensors like Thermocouple RTD Thermocouple  load cell strain gauge LVDT smoke sensors speed sensor Limit Switch Photo sensors Optocouplor Proximity Sensor 127 Fiber optic communication trainer 128 Seven segment DPM 129 LCD based DPM 130 SMPS of different make 131 UPS trainer 132 Mobile phone Trainer 133 Cell phone power source with charger chords for different cell phones 134 LCD TV Trainer kit 135 LCD TV 136 LED TV Trainer kit 137 LED TV 138 Home theatre system 139 Solar Training Kit Simulator 140 LED lighting system 141 Trammel 142 Steel Rule with metric British graduation 143 Compressor unit 144 Try Square 145 Pocker. 146 Caliper inside spring type 147 Mallet. 148 Caliper hermaphrodite spring type 149 Carrier for mounting components such as PB relay boxes. 150 Caliper outside spring type 151 Aviation Snips straight Cut 152 Cut section model for pneumatic components 153 Divider spring type 154 Planishing hammer. 155 Scriber 156 Centre Punch 157 Screw driver 158 Depthmicrometer. 0-25 mm 159 Stake grooving. 160 Hammer ball peen With handle 161 Comparators Gauge - Dial Indication with Stand and Bracket 162 Hammer ball peen With handle. 163 File flat - second cut 164 Engineer s try square knife- edge 165 File flat smooth 166 File half round second cut 150 mm 167 Vernier Bevel protector 168 Carbide Wear Block 169 Carbide Wear Block 170 Dot punch 171 Spirit Level metal Type - 2 172 Arm strong type tool bit holder 173 Combination Set 174 Arm strong type tool bit holder 175 Arm strong type tool bit holder 176 Stillson wrenches 177 Micrometer inside with extension rods 178 Vernier caliper 179 Adjustable pipe chain tonge to take pipes 180 Adjustable spanner 181 Screw pitch gauge Metric 182 Surface plateC.IGranite with Stand and Cover 183 Marking table Mild steel 184 Universal scribing block 185 V-Block pair with clamps 186 Punch letter set 187 Portable hand drill Electric 188 File knife edge smooth 189 File feather edge smooth 190 File triangular smooth 191 File round second cut 192 File square second cut 193 File flat second cut safe edge 194 File half round second cut 195 File round bastard. 196 File hand second cut 197 File card 198 Oil Can 199 Wooden handle forged Soldering Iron copper bit 200 Blow Lamp 0.50 liters. 201 Spanner adjustable 202 Double Ended tubular Box spanner set with Tommy bar 203 Glass magnifying 204 Clamp C 205 Hand Reamer set Tapar pin straight flute 206 Machine Reamer parallel Helical flute 207 Scraper flat 208 Scraper triangular 209 Scraper half round 210 Pipe wrench 211 Adjustable pipe die set BSP 212 Machine vice - Swivel Base 213 Machine vice - Swivel Base. 214 Sleeve drill Morse 215 Vice bench 216 Wing compass 217 Power tools for fastening 218 Different Profile gauges Plate type - For demonstration 219 Knurling tool Diamond 220 Knurling tool straight 221 Knurling tool Diagonal 222 Indexable boring bar with inserts 223 Machine maintenance mannual for Lathe Pedestal grinder Drill machine Power saw 224 Temperature gauge 225 Dowel pin straight 226 Standard Tap screws 227 Lapping plate 228 Caps screws 229 Drill gauges 230 Cast Iron Globe Valve Flanged type 231 C.I. Sluice Gate valve flanged type 232 Stop cock 233 Slip-on Forged steel Flange 234 Pipe threading die with handle 235 Pulleys for V-belt or Flat belt 236 V-belt and Flat belt 237 Packing gasket 238 Washer clutch keys jib cotter circlip 239 Bearing different types 240 Lifting sling 241 Bearing extractor 242 Pulley extractor 243 File half round bastard 244 REFRIGERATOR ( 365 LTR ) DOUBLE DOOR 245 GAS TANDOOR WITH SKEWER ROTI SET ( 12 SKEWERS ) COMMERCIAL 246 BAIN MARIE 2 PAN WELL 55.5 X 70 X 20 CM 247 CHINESE GAS BURNER DURA STEEL 60 X 24 X 30 248 SALAMANDER AVON REFRIGERATION 600 X 510 X 550 MM 249 ELECTRONIC GEYSER 25 LTR( HAVELLS, ADONIA )DIGITAL TYPE 250 DOUGH KNEADING MACHINE ( 5KG CAP )1000 WATT, STAND MIXER 251 WATER BOILER ( ELECTRICAL 15 LTR)2000 WATTS 252 MIXER CUM GRINDER FOOD PROCESSOR 1 NOX 1000 WATT,WITH 7 ACCESSORIES 253 WOK CHINESE KADAI 16 DIA METER 254 PRESSURE COOKER ( 5 LTR ) CAP 255 EGG CUTTER STAINLESS STEEL 256 STEAK HAMMER ALUMINUM 257 MS CUPBOARD INTERIO 2 DOOR WITH 3 SELVES 7 X 3 X 3 258 HAND BLENDER 250 WATT 259 SIZZLER PLATES ( 17-18 DIA) HEAVY FINE QUALITY 260 COFFEE URNS , ( 40 CUP CAPACITY) 261 CHINESE CHOPPER 262 MS CHOPPER 600WATT 263 KITCHEN KNIFE, BIG CARTINI 8 BLADE 264 VEGETABLE KNIFE 13 CM BLADE, MEYER CERAMIC KNIFE 265 BREAD KNIFE 8 BLADE 266 PASTA MACHINE , 150 WATT 267 WATER PURIFIER REVERSE OSMOSIS 6.5 LTS UV + UF 268 SODA MAKER MACHINE HEAVY DUTY INDUSTRIAL MODEL KVR - 8 FLAVOR 269 ESPRESSO MACHINE COFFEE GRINDER 1300 WATT 270 MINIBAR FRIDGE 271 LED 42” HD DISPLAY 272 MUSIC SYSTEM WITH DVD PLAYERS CONCEALED SPEAKER, 5.1 CHANNEL 273 ELECTRIC OVEN 20 LTRS (IFB, WONDER CHEF,HAVELLS) 274 DISPLAY FOOD CABINET OSHAM SLIDING DOOR ,814X 641 X 831 MM W X D X H 275 ROOM SERVICE TROLLEY HOME CENTRE MONTOYA TYPE 276 CARAFE BOROSIL SMALL WITH STRAINERS, 350 ML 277 CARAFE BOROSIL LARGE WITH STRAINERS , 700ML 278 SOUP FLASK TERMOSTEEL ( 500 ML ) 279 WATER FLASK THERMOSTEEL FLIP LID FLASK 1000ML SILVER 280 PASTA TROLLEY GOLDEN LINE 4 CASTOR WHEEL 281 EPABX SYSTEM + AVS MACHINE S- TECH CS432, 4 MAIN TRUNK LINES & 32 EXTENSION 282 SAFE DEPOSIT LOCKER / FORTE 40 BIOMETRIC SAFE 283 UMBRELLAS , CITIZEN 3 FOLD 284 STEEL CUPBOARD WITH UNBREAKABLE GLASS , INTERIO 4 SHELVES 7.5 X 3 X 2.5 285 FRIDGE WITH CABINET 275 LTR 286 VACUUM CLEANER WET & DRY 287 WASHING MACHINE 8KG FULLY AUTOMATIC 5 X 1400 RPM , INBUILT HEATER 288 WATER HEATER 25 LTRS HSE-SES , 2000 WATT 289 CARPET EXTRACTOR, CARPET CLEANER MACHINE 1100 , W PRO E X 25 290 HIGH PRESSURE JET CLEANER , KK PWIN 165 1800 WATT , 165 BAR 291 LUGGAGE RACK MINT WOOD H 27.5 X W 28.5 X D 12.8 292 HEAVY BOTTOM PAN 10 LTR NON STICK CANEROLI 40 CM 293 COOKER ( 2 LTR ) CLASSICS 2L ALUMINUM 294 MANDOLIN GRATER ADJUSTABLE SS 4 BLADES WITH HANDLE 295 PROBE THERMOMETER ( 75 - 100 DEGREE CELCIUS ) ST 9283B LCD , DIGITAL MULTISTEM THERMOMETER 296 CAKE STAND ( SS ) 13 TOP 297 HEAT PROOF GLOVES GRIPWELL KELVES PALM LEATHER HEAT RESISTANT GLOVES 298 GRINDING STONE FINE GRINDER STONE 10 299 PIZZA CUTTER STAINLESS STEEL 300 COOKIE CUTTER ( 5 SHAPES ) ALLAMWAR 12 PCS STAINLESS STEEL CUTTER SET 301 SANDWICH GRILLER / TOASTER SW X 400 700 WATT ( 302 JUICER MACHINE PHILIPS HR 1863/20 , 2 LTR 303 ROLLING BASE WOODEN 10 304 FRYING PAN NON STICK GRANITE FRY PAN ( 280 MM) BLACK 305 FRYING PAN LARGE NON STICK FRY PAN 240 MM0 306 CLEVER STAINLESS STEEL 2 IN 1 VEGETABLE SCISSORS 307 Steel rule 308 Outside spring caliper 309 Inside spring caliper 310 Hermaphrodite caliper 311 Divider spring 312 Centre Punch 313 Hammer 314 Cold chisel flat 315 File flat bastard 316 File flat 317 File flat smooth 318 Screw Driver 319 Scribing blockuniversal 320 Screw driver heavy duty 321 Spindle blade screw driver 322 Solid parallels in pairs different sizes in Metric 323 Oil stone 324 Punch letter set 325 Punch number set 326 Drill Chuck 327 File Half round 328 File triangular smooth 329 Reamer 330 Reamer adjustable 331 Tool bits holder Armstrong R.H. 332 Table chuck 333 Machine vice 334 Compound angle vice standard sine 335 Universal Machine Vice 336 Shaper tool holder turret type to suit the machine 337 Base chuck forslotter to suit the machine 338 Milling Cutter Side and face cutter 339 Milling Cutter Side and face cutter Adison 340 Milling Cutter Adison 341 Milling Cutter -Side and face cutter adison 342 Milling Cutter - Double Angle Unequal. adison 343 Milling Cutter - Double Angle Unequal. adison 344 Milling Cutter - Single Angle.. adison 345 Milling Cutter - Slitting Saw Cutter adison 346 Milling Cutter - Slitting Saw Cutter. adison 347 Milling Cutter - Shell End Mill.Parallel Shank end mills adison 348 Milling Cutter - Parallel Shank end mills. adison 349 Milling Cutter -mills. Parallel Shank end mills.. adison 350 Milling Cutter - Parallel Shank end mills… adison 351 Milling Cutter - Parallel Shank end mills.... adison 352 Milling Cutter - T Slot Cutter with Parallel Shank adison 353 Micrometer outside. 354 Micrometer depth gauge 355 Digital micrometer 356 Vernier Caliper 357 Direct reading vernier caliper 358 Combination set 359 Vernier bevel protractor 360 Telescopic gauge 361 Centre punch 362 Divider spring joint 363 Caliper odd leg spring joint 364 Wrench adjustable 365 Spanner double ended 366 Pipe wrench 367 Plumbing hammer weight 368 Four way reversible valve 369 Tape measuringgraduation in mm 370 Voltmeter ACDC portable precision grade Digital Panel board type 371 Rule steel 372 Drawing Board 373 Easel a Type stand 374 Hack Saw with Frame 375 Chisel Knife 376 Chisel Knife- 8mm 377 Chisel Knife- 10mm 378 Chisel Knife 20mm 379 Chisel Knife- 30mm 380 Diamond Glazier Knife 381 Paint Tin Opener 382 Shave Huck Knife 383 Glider Knife 384 Paint Burner Acetylene Gas 385 Screw Driver 386 Mild Steel Panels 387 Sink Stainless steel 388 Suction feed spray gun with accessories 389 Infra red lamp 390 Pneumatic Polishing Machine with Pads 391 Pipe vice 392 Pipe wranch 10 393 Pipe wranch 16 394 flat file- smooth finish 395 Circuler cut file 396 Raft cut 397 Pipe dai set metric Inches 398 Gun Spray with Gravity Feed Cup with Complete accessories with Complete accessories 13ltr 399 Gun Spray with Gravity Feed Cup with Complete accessories.. 400 Conventional Spray Gun For Pressure Feed 401 Pencil Hardness Tester 402 Air Compressor single Phase 1 HP 403 File - Flat - Bastard 404 File - Flat - Safe Edge 405 Cooling tower 406 File flat roughdouble cut 407 File half round fine double cut 408 File round finedouble cut 409 File flat fine double cut 410 File square finedouble cut 411 File triangular fine double cut 412 Try square 413 Divider spring joint 414 Caliper spring joint in side 415 Caliper odd legspring joint 416 Hammer ball pane 417 Cold Chisel flat and cross cut 418 Engineers rule 419 Tape measuring 420 Pliers flat nose 421 Line tester 422 Tweezers 423 Oil can 424 Surface Gauge universal 425 Bench vice 426 Hack saw tubular metal frame adjustable 427 Snip sheet metal straight nose 428 Snip sheet metal curved nose 429 Wooden mallet Nylon mallet 430 Round Punch 6mm 431 Round Punch 432 Round Punch 4mm 433 Screw driver plastic handle 434 Screw driver plastic handle Flat tip 435 Philips screw driver 436 Soldering ironexchangeable copper tip 437 Knife foldedstainless steel - 438 Tenon saw 439 Firmer chisel 440 Fire buckets 441 Quick couplesprocess tube adopter 442 Flaring tool set single type for tube. 443 Swaging tool punch type set of size for tube. external type for copper tube 444 Pipe cutter miniature for copper tube 445 Pinch of tool for copper tube 446 Ratchet spanner 447 Capillary plug gauge 448 Piercing pliers 449 Spanner double ended 450 Wrench adjustable 451 Wrench adjustable length 250mm 452 Valve key handleTreated as consumable 453 Hollo Punch hole for cutting gasket 454 Scissor gasketcutting stainless steel 455 L-Allen key 456 T-Allen key set 457 Pipe cutter withbuilt in reamer and space cutter for copper tube 458 Lapping plate 459 Hammer ball peen 460 Tap set withmatching drills 461 Tap set withmatching drills V to 462 Piercing Valve 463 Feeler gauge 464 Tape measuringgraduation in mm 465 Ammeter ACDCportable precision grade Digital Panel board type 466 Multi meter digital type 467 C.R.O Single beam 468 C.R.O Dual trace Double beam 469 A.F.O Oscillators 470 Pressure gauge 471 Compound gauge Digital type 472 Electronic leak detector 473 Sling psychro meter mounted on aluminum back 474 Stop watch 475 Multi meter 476 Sensor thermometer digital 477 filler guage 478 Wire gauge 479 Dial thermometer 480 Compressors testers for small hermetic compressors 481 Precision set of T5 T6 T7 screwdrivers- 482 Jacket stripper Coring tool for 500 series cable 483 Center conductor cleaner 484 Universal drop trimmer for RG 6/11 cables 485 F - connector tool for RG 6/11 cables 486 F connector compression tool for RG 6/11 cables 487 Solar Training Kit Simulator With built in meters for DCV DCA AC Multifunction Meter for ACI ACV Power Frequency Protection Circuits BS-10 terminals formaking the connection Single Dual axis tracking system Charge Controller PWM based MPPT Charging Stage Bulk Absorptions and Float 488 LED lighting system Measurement of Power Voltage Current Power Factor and Light output performance of different lighting products like LED CFL at variable inputvoltages 0 to 245V variable AC 489 PLC Systems with digital IP OP modules and software 6 Digital Inputs 24V DC. 4 Digital Outputs 24V DC 2K Words of memory 256 words of register. Powerful features like built in Floating Point Sub Routines etc.One RS232 C communication facility for PC interface. Three channels can be configured as follows Pulse width modulation output or Pulse train outputor High speed counter input. 490 Electronic Pneumatics Trainer kit 491 CRO dual trace 20 MHZ ( Component testing facilities ) 492 Steel wire Brush 50mmx150mm 493 carborundum 15 x 5 x 4 cm smooth 494 Straight edge gauge 2 ft. 495 Straight edge gauge 4 ft. 496 Surface gauge with dial test indicator plunger type i.e. 0.01 mm 497 Tachometer Counting type 498 Taps and Dies complete sets 5 types 499 Taps and wrenches - Metric 500 Temperature gauge 0- 100 deg c 501 Thread pitch gauge metric BSW 502 Timing lighter 503 Universal puller for removing pulleys bearings 504 V Block 75 x 38 mm pair with Clamps 505 Vacuum gauge to read 0 to 760 mm of Hg 506 Valve Lifter 507 Valve spring compressor universal 508 vernier caliper 0-300 mm with least count 0.02mm 509 Vice grip pliers 510 Voltmeter 50VDC 511 Hand Shear Universal 250mm 512 Solid Parallels in pairs Different size in Metric 513 Spanner Clyburn 15 514 Spanner T. flocks for 515 Spark lighter 516 Spark plug spanner 14mm x 18mm x Size 517 Spirit level 2V 250 05 518 Spring tension tester 519 Stake grooving. 520 Spanners socket with speed handle T-bar ratchet and universal upto 32 mm set of 28 pieces with box 521 Steel tool box with lock and key folding type 400x200x150 mm 522 Wire cutter and stripper 523 Car Jet washer with standard accessories 524 Chaser hard WV 9 to 40 T.P.I. set of 11 external. 525 Chaser hand WW 9 to 40 T.P.I. set of 11 internal. 526 Chisel 10 cm flat 527 Chisels cross cut 200 mm X 6mm 528 Circlip pliers Expanding and contracting type 15cm and 20cm each 529 Clamps C 100mm 530 Clamps C 150mm 531 Clamps C 200mm 532 Compression testing gauge suitable for diesel Engine 533 Connecting rod alignment fixture 534 Copper bit soldering iron 0.25 Kg 535 Cylinder bore gauge capacity 20 to 160 mm 536 DC Ohmmeter 0 to 300 Ohms mid scales at 20 Ohms 537 Depth micrometer 0- 25mm 538 Dial gauge type 1 Gr. A complete with clamping devices and stand 539 Dividers 15 cm Spring 540 Drift Punch Copper 15 Cm 541 Drift copper 10 x 15 12 mm 542 Drill point angle gauge 543 Drill twist 1.5 mm to 15 mm various sizes by 0.5 mm 544 230 V 25 watts Electric Soldering Iron 230 V 60 watts 545 Electric testing screw driver 546 Engineers square 15 cm. Blade 547 Engineers stethoscope 548 Equipment puncture in box 549 File flat 20 cm bastard 550 File half round 20 cm second cut 551 File Square 20 cm second cut 552 Files assorted sizes and types including safe edge file 20 Nos 553 Glow plug tester 554 Granite surface plate 1600 x 1000 with stand and cover 555 Grease Gun 556 Grover- 34mm. 557 6mm Grover 558 Growler 559 Hacksaw frame adjustable 20-30 cm 560 Hammer Chipping 0.25 Kg 561 Hammer copper 1 Kg with handle 562 Hammer Mallet 563 Hammer Plastic 564 Hand operated crimping tool i for crimping up to 4mm and ii for crimping up to 10mm 565 Hand reamers adjustable 10.5 to 11.25 mm 11.25 to 12.75 mm 12.75 to 14.25 mm and 14.25 to 15.75 mm 566 Hand vice 37 mm 567 High rate discharge tester cell tester 568 Left cut snips 250mm 569 Magneto spanner set with 8 spanners 570 Magnifying glass 75mm 571 Marking out table 90X60X90 cm 572 Multi Scan Tool 573 Multimeter digital 574 Oil Stone 15 cm x 5 cm x 2.5 cm 575 Oscilloscope 20MHz 576 Outside micrometer 0 to 25 mm 577 Outside micrometer 25 to 50 mm 578 Pat melting 579 Philips Screw Driver set of 5 pieces 100 mm to 300 mm 580 Pipe cutting tool 581 Pipe flaring tool 582 Piston Ring groove cleaner 583 Pliers side cutting 15 cm 584 Poker 585 Portable oil monitoring Indicator 586 Power Supply 0-12 v lamp 587 Radiator pressure cap 588 Rear axle assembly- gear box steering box assembly of the diesel engine 589 Right cut snips 250mm 590 Rivet sets snap and Dolly combined 3mm 4mm 6mm 591 Scriber 15 cm 592 Scriber with scribing black universal 593 Set of stock and dies - UNC UNF and metric 594 Shear Tin Mans 450 mm x 600mm 595 Sheet Metal Gauge 596 Soldering Copper Hatchet type 500gms 597 Sher Tinmans 300mm 598 Shovel 599 Ammeter 300A 60A DC with external shunt 600 Angle plate adjustable 250x150x175 601 Angle plate size 200x100x200mm 602 Arbor press hand operated 2 ton capacity 603 Auto Electrical test bench 604 Battery charger 605 Belt Tensioner gauge 606 Spanner ring set of 12 metric sizes 6 to 32 mm. 607 Blow Lamp 1 litre 608 AC alternator slip ring puller 609 Allen Key set of 12 2mm to 14mm pieces 610 Air blow gun with standard accessories 611 Alternator for tractor different type Mico , Bosch, tux 612 Hands file 20 cm. Second cut flat 613 Caliper outside spring joint 614 Caliper inside spring joint 615 Caliper odd-leg firm joint 616 Steel Rule 617 Scriber 618 Hammer ball peen 619 Centre punch 620 Prick punch 621 Divider spring joint 622 Safety goggles clear glass Good quality 623 Marking table CI 624 Bench vice 125 mm jaw 625 V - Block 626 Pliers flat nose 627 Micrometer Outside 628 Micrometer Inside 629 Vernier Bevel Protractor 630 Vernier Micrometer 631 Universal Dial Test Indicator - Plunger Type 632 Vernier Height Gauge 633 Plain Ring and Plug Gauge 634 Drill Twist Set 635 Reamer machine 636 Combination Drill Centre Drill 637 Tool Bit assorted sizes on holder 638 Chalk Board on mobile stand 639 Desk 640 Hand Chaser 641 Hand Chaser 642 Revolving Centrer to suit Lathe tailstock 643 Tool Cemented carbide assorted shaped External for steel turning 644 Machine Chase 645 Coventry Die head 646 Lathe Mandrels Diff. Types 647 Coventry Type Die Head Self opening 648 Stainless steel rule 649 Hack saw frame 650 File half round 651 File flat 652 Try square 653 Earth clamp 654 Electrode holder ESAB 655 Oxygen Gas Pressure regulator double stage ESAB 656 Acetylene Gas Pressure ESAB 657 CO2 Gas pressure regulator with flow meter ESAB 658 Argon Gas pressure regulator ESAB 659 First Aid box ESAB 660 Flash back arrester torch mounted ESAB 661 Flash back arrester cylinder mounted ESAB 662 Screw Driver 663 Screw Driver 664 Terminal screw Driver 665 Hammer Ball peen 666 Neon tester pencil bit type 667 Small crimping tools assorted 668 Spanner set DE 669 Screw driver set set of 5 670 File half round 2nd cut 671 File round 2nd cut 672 Soldering iron TONY 673 Neon tester 674 Spade 675 Sickle 676 Khurpa 677 Kasola 678 Trifali 679 Zindra 680 Dori (Nylon rope) 681 Wheel hand hoe 682 pH meter 683 Electrical conductivity meter 684 Flame photometer 685 Spectrophotometer 686 Atomic absorption spectrophotometer 687 Shaking apparatus 688 Distillation unit 689 Ammonia distillation unit (with heaters) 690 Gas connection 691 Sampling tools (augers) 692 Refrigerator 693 Gas cylinders with regulators 694 Gas cylinders with regulators 695 Gas cylinders with regulators 696 Incubator (with temperature control) 697 Infrared soil moisture estimation unit 698 Electric oven 699 Soil cores 700 Soil infiltratormeter 701 GPS system with mobile phone 702 Table top centrifuge 703 Auto Titrator 704 Battery charger
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
10.
Public Administrative Department #10579286 Price Bid
supply of material for Shahid Bhagat Singh Smarak Hetu Vibhin Samagri Aapurti Ka Karya Shahid Bhagat Singh Smarak Hetu Vibhin Samagri Aapurti Ka Karya , Part - A Fountain Supplygeyser Jet Fountain Nozzel Metal-Gun Metal With Cromplated Size- Of Small Size Inner Dia- 50 Mmupper Dia- 78Mm Height- 150 Mm Make-:Creative, Aquresi, Dms , Iso Company ( Inclu , Supply Ofangular Valve Metal-Gun Metal With Cromplated Size- Inner Dia- 20 Mmouter Dia- 25 Mm Height- 65 Mm Make- Creative, Aquresi, Dms, Iso Company , Necessary Plumbing Work Of All Valve, Unioun Pipeshould Beupvc Pipe And Fitting & Brassball Valv Etc Isi In Make- Astral, , Supply Of Electric Panel 10 Hp, Big Size With16 / 18 Gascolour Powder Coated Weather Proof Bodyamp & Volt Meter- Essma / Ae / L&T Switch Ampmeter, Voltmeter And Other Equipment Connector Transformer- Essma / Ae Indicator- Led Type Push Button- L&T / Bch Mcb- L&T / Fchneider Vss- L&T Auto Switch- Modern / Gelco Connector- 16 Amp.- 22 Amp. In Bch / L&T Over Load Reley- Vch / L&T Connection Strip- Airon 6 Installation, Testing & Co , Installation, Testing & Commissioning , Lighting Details Supplyled Base Waterproof Programmable Colour Changing Light As Per Side Requirementno. Of Power Led-108 Nos Volt- 18V Dc Watt - 27Watt Body - Abs Pvc Colour- Programmable Size- 200 Mm Dia & 30Mm Height Minimum Make-:Creative, Aquresi, Dms, Iso Company , Supplyof Led Base Waterproof Programmable Colour Changing Light As Per Side Requirementno. Of Power Led-54 Nos Volt- 18V Dc Watt - 09Watt Body - Abs Pvc Colour- Programmable Size- 140 Mm Dia & 65Mm Height Minimum Make-:Creative, Aquresi, Dms, Iso Company , Necessary Electric Work As Per Side Requirement Isi Make Condute Pipe & Submersible 3 Core Wire Make- Aroma, Finolex, Jmp, Only Standard Quality 4 Core Wire , Supply Of Microprocessing Controller With 18 V Transformeras Perv Side Requirement And Contrast Having Aslow, Medium, Fast Mode For Capacitymake-:Creative, Aquresi, Dms, Iso Company , Part B - Flag ( A ) Supply Of 30.50 M Flag Mast Mast Shaft Shall Be In Three Sections, Hot Dip Galvanised And Suitable For Wind Velocity As Per Is 875. Mast Shall Be Suitable For Indian Tri Colour Flag Size 30 Ft X 20 Ft. System For Raising Lowering Of Flag It Shall Have Double Drum Winch , 6 Mm Dia. Galvanized Wire Rope And Integral Power Tool For The Raising And Lowering Of Flag. Suitable Control Panel Shall Be Provided For Reversing Operation Of Power Tool Motor. Supply Of Aviation System With 3C X 2.5 Sq Mm Cu Armoured Cable. Painting Of 30.5 M Flag Mast Pu Painting Of High Mast Shaft With A Coating Of Etch Primer, Primer And Pu Paint. ( B ) Supply Of Foundation Bolts Manufactured From Special Steel Along With Nuts, Washers , Anchor Plates And Templates ( For 30.50 M Hm ) ( C ) Supply Of 01 Nos Led Aviation Obstruction Light ( D ) Supply Of 5M High Hot Dip Galvanised Octagonal Pole Suitable To Mount 1 No , Led 350 W Flood Light Fittings At Top With Suitable Mounting Arrangement At Bottom ( E ) Supply Of Foundation Bolts Manufactured From Special Steel Along With Nuts, Washers Etc ( For 5 M Pole ) ( F ) Supply Of Led Flood Light Luminaries Type 200 Watt Withuitable Arrangement & Supports For Mounting Luminary On Flag. ( G ) Supply Of National Flag Ofsize 20 Ft X 30Ft In 100% Knitted Polyester ( 140 Gsm ) . With Reinforced Super -Strong Nylon Webbing On All 3 Sides & Rope / Toggle Sleeve. ** There Is No Warranty On Indian National Flag , Part - C Irrigation Work ( 1 ) Upvc Sch. 40 Pipe , Pvc Pipe 6 Kg / Cm² , Pop Up Sprinkler Rotary Nozzle , Swing Joint , Pp Saddle , Drip Lateral Black 2.5 Kg / Cm² Brown , Drip Line 50 Cm X 4 Lph Brown , Bubbler , Pvc Ball Valve , Round Valve Box , Disc Filter 25 M³ / Hr , Additional Pvc Fittings And Accessories , Part - Dstone Pillar & Stone Pot & Stone Letters & Stone Motif Providingpink Sand Stone Pole 3.00M High, As Per Drawing And Specification , Supply Decorative Pots For Asthetic Appearance Made Up Of Pink Sand Stone As Per Drawing And Design , Supply Mint Sand Stone Letter As Per Drawing And Design , Providing Readymade Heart Shape Signage Withinside Led Light _ In 8Mm Acrylic Sheet , Supplyof Pink Sand Stone Motif As Per Drawing And Design , Supply Decorative Farmer Plow For Asthetic Appearance Made Up Of Pink Sand Stone As Per Drawing And Design , Part - E Sculptures Providing Marble Sculpture Of Saheedbhagat Singhwith Paint Fin. To Be Placed On Podiums , Providing Marble Sculpturesswami Keshwanand Ji Sculptures With Paint Fin. To Be Placed On Podiums , Providingmarble Sculpture Forkids Sculptures With Paint Fin. To Be Placed On Podiums
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
11.
Civil Aviation #10546587 Price Bid
Tender For Provision Of Guard Lights At Tuticorin Airport; 1 SITC of FAA/ICAO/DGCA-CAR compliant LED based Runway Guard lightfor compliance as per ICAO/DGCA-CAR aviation visual aids requirements complete with LED lamp/s with integral driver, electronics suitable for operation along with existing 2.8-6.6 Amps current Circuit & CCRs , with all accessories and cable lead with plug ready for site installation on circular Housing box ,suitable for all weather operation, conforming to latest ICAO / CAR requirement as per specifications complete as required. 2 Supply of45 W, 6.6A/6.6A rating 5000V, 50 Hz Series Isolating Transformers encapsulated in black cross linked polychloroprene compound like TPE /TPR / TPV with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned LED runway Guard light fittings complete as per Technical Specifications. 3 SITC of CI Adaptor / collar box round type of outside dia 330mm of 150mm height made of 10 mm thick cast iron moulding all round except on top surface which is 15 mm thick cast iron moulding suitable to receive a light fitting base plate on the top. The CI collar shall have a clear opening of 220 mm at the top and bottom surface and 6 nos M-10 tapped holes at the centre of 260 mm at top and bottom to fix the collar including providing 6 nos. M-10 bolts (SS) and a base. The cost shall include necessary bitumen/concrete kerf/core cutting and concrete works for fixing the same and laying of connceting pipes. 4 Installation of CI Transformer housing box with a base concrete of 1:3:6 of size 630*630*100mm thick all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cemeny concrete including excavation of existing Bituminous Road/Pavement/shoulder of the runway, disposal of material within 50 mtrs lead, providing and fixing 300mm long 1/2 dia B class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling. The boxes are aligned in such way that the hole centres fall in straight line etc., complete as required. 5 Supply of 2C x 4 sq.mm., 600V Grade Flexible Copper Conductor, EPR insulated & CPE (Chlorinated Polyethylen, cross - linked, heavy duty) outer sheath (Black colour) Secondary cable for Airport lighting circuits conforming as specified in particular specification sizes as required. 6 Supply and installation of 2 pin secondary plug suitable for connection of isolation transformer and to light fixture complete as required 7 Supply of plug & receptacle of size 6 sqmm type I, class B connector & suitable for attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 8 Laying of one number of PVC insulated and PVC sheathed cable of 5KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 9 Providing and Laying of 25 mm dia B class GI Pipe in Runway for runway guard light fittings. Job Involve kerf cutting and refiling the same with (fast grouting) cement concrecting complete with threading and alignment of pipe with transformer housing box as required. 10 Supply offollwing size5 KV Grade stranded Copper Conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and rodent treated, airport lightingcable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in particular specifications of the following sizes as required. 1 Core X 6 Sq mm. 11 SITC ofIndoor, Air cooled Type constant current regulator of Thyristor Controlled microprocessor based suitable for use on 230V+ 10% volts, 50/60 Hz, Input AC Supply with Output Power of 7.5 KW at 6.6 Amps with 5 Steps variation of Current Output suitable for local and Remote Control Operation with 24/48 VDC integral Control Supply complete with output current indicated on multifuction digital display, over current, over voltagte, earth fault protection and earth leakage meter, positive feed back indication equipments,complete with 5 KV grade current transformer and relays, contactors interconnection with multicore control cable junction box etc complete as per AAI specifications as required. (The CCR should be supplied with modules connecting to available NASU make ALCMS system at Tuticorin Airport) 12 Supplying and Laying of HDPE pipe of 63mm OD of PE 80 PN 6 ISI marked along with all accessories like socket, bend,couplers etc. confirming to IS 4984,complete with fitting and cutting, jointing etc. direct in ground at a depth of 0.8m below the ground level i/c excavation and refilling the trench but excluding sand cushioining and protective etc as required. 13 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 14 Supply of following size of XLPE insulated PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 2 core x 25 sq.mm 15 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2Cx 25 sqmm 16 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, getting out the excavated soil, refilling with excavated soil after laying of cable/ pipe/ for site requirement etc. and disposal of surplus excavated soil as directed, within a lead of 50 meters, without ramming and watering etc as required. 17 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 18 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of upto 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe/ Masonary Duct as required. 19 Supply of following size of XLPE insulated PVC sheathed copper conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 12Cx 1.5 sqmm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
12.
Public Administrative Department #10363290 Price Bid
Tender For Electrification Work From Cello Glass Were To Nimbeshwar Mahadev Temple At Khudala Falna; 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Poles with Octagonal Cross Section8 Mtr 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .LED Street Light fixture with Minimum lumen output 8700 lm 4 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. 5 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 Core 10.0 Sq. mm 6 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 7 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure A attached with this BSR 1.5 Sq. mm 2 Core 8 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .One day & week reserve (Analog type ) 9 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR pole Power contactors with following AC 3 Rating 40 Amp 10 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional tech Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 11 Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole Isolator 40 A rating 12 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 13 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 14 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .8 SWG G.I. ( Hot Dipped ) Wire 15 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .B class 50mm dia 16 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety.Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screenrinting on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 omplianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .High Power LED Flood Light Minimum lumen output 25000 lm 17 Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test . All as per pre approved by Engineer in-charge. All as per pre approved by Engineer in-charge. For additional technical parameters of product12.5 Mtr HM (in 2 section) suitable for 6 No. Luminaries 2 no. rope for lantern carrage & 2 no. rope for winch assembly
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
13.
Civil Aviation #10289004 AOC
Tender For Sitc Of 100 Feet Flag High Mast System At Rajkot International Airport.; Design, supply, Installation,Erection, Testing and commissioning of 100 ft (30.5 Mtrs) High Flag Mast Shaft in three telescopic sections (with base plate welded to the bottom sections) made ofhot dip galvanizedsteel totally on externally and internally& suitable for wind velocityas per IS:875 (latest revision) along with special type domeincluding supply and installation of twin dome LED aviation light system alongwith 3C x 4 sqmm copper conductor armoured cable & other assemblies etcas per the tender specifications as required with following accessories. a) Raising and lowering mechanism consisting of flag with double drum winch assembly, head frame assembly on top with self lubricating bearing, stainless steel wire ropes of minimum 6 mm. dia (Grade316) etc. designed to operate with integral electric driven power tool motor of 2 hp capacity and also suitable for manual operation.b) Providing and fixing of foundation bolts 12 nos of M30 X 850 size manufactured from special steel along with nuts, washers, suitable size anchor plate and template etc. as required.c) Design & construction of shallow foundation of suitable size with M20 grade concretefor high mast tower suitable for safe soil bearing capacity as per IS specifications and site conditions at required depth with all materials, labor and soil investigation.d) Painting of Flag mast PU painting of High Mast shaft with a coating of etch primer and PU paint(Factory Painted)e) Providing and fixing of DWC HDPE pipe of size 40 mm dia (2 pieces of min. 0.75 m length) in the foundation. 2 Design & supply,Installation,Erection, Testing and commissioning of 5 mtrs. Height Hot Dip GI OCTAGONAL continuously tapered galvanised pole with suitable to mount 2 nos. LED 300W-500W flood light fittings at top, suitable for wind velocity as per IS 875 (but not less than 50 m/sec.), fabricated out of 3 mm thick high tensile sheet steel in single piece construction having 130mm bottom, 70 mm top, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolts & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as required for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick bakelite sheet with 63 Amp heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables, including supply of 2A, 10kA, DP, C series, MCB for each fixture connections, earthing bolts for continuous earth connection complete, as required as per technical specifications.a) Design & construction of shallow foundation of suitable size with M20 grade concrete foundation including excavation and refilling including positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 40 mm dia (2 pieces of min. 0.75 m length) in the foundation.b) Erection of pole with the help of suitable equipments and T&P.c) All minor civil foundation works for installation and commissioning as required. 3 Design and Supply ofIndian National Flag of Size 30 ft x 20 ft in 100% knitted polyester (min 140 GSM) with reinforced super strong nylon webbing on all three sides & rope / toggle sleeve complete as per relevant IS code. 4 Installation, Erection, Testing & Commissioning of Indian National Flag ( supplied as per Item no -03 ) 5 Supply, installation, testing and commissioning for 3 KVA(1 Ph- 1Ph) online UPS including batteries (SMF type) to ensure minimum 30 mins ofbattery Back up for the system, suitable for operation on 230 V 50 Hz AC supply with outputvoltage 230 V 50 Hz etc. complete as required. 6 Supply, Installation,Testing and Commisioning of suitable size dust & vermin proof, out door type, floor mounted Feeder Pillar Panel on cement concrete/MS channel foundation, fabricated with 14 SWG CRCA Sheet and suitable size MS angle complete with detachable gland plate and front hinged door locking arrangment duly powder coated of approved shade as per manufacturer drawings/SLD. The panel should be suitable to accommodate 3 KVA UPS alongwith batterieshaving the required MCB/Contacters/auto manual switch/MCB LED indicator lamp/Suitable capacity Busbaras required, accessories including inter connection, wiring with minimum 2.5 sqmm flexible copper wire & provision for earth connection etc complete as required:Incoming:i) 63A, 10KA FP MCB -01 No.ii) 63A TP contactors operated through 24 hrs time switch for automatic switching of luminaries along with Auto / Manual selector switch-01 no. iii) 01 Set of phase indicating lamps, LED type for R,Y,B, ON and OFF indication lamps controlled by 2 A MCB. iv) 01 Nos. digital multifunction meter for 3 Phase, 4 wire operation with LED display. Outgoing:i ) 32 A, 10 kA, C-series, FP MCB- 02 nos. with all accessories and internal wiring etc as required.ii) 16 A, 10 kA, C-series, DP MCB- 02 nos. with all accessories and internal wiring etc as required.iii) 10A, 10 kA,C-series, SP MCB-02 nos. with all accessories and internal wiring etc as required. iv) 03 Sets of phase indicating lamps, LED type for ON and OFF indication lamps controlled by 2 A MCB. v) Control system for Raising/ Lowering of Flag-01 No. with one addition wired remote control forRaising / Lowering of Flag.iv) Suitable capacity overload relay & single phase preventer. v) Astronomical Timer circuit,switch for AUTO ON,AUTO OFF with manual overide facility.Busbar:100A TPN, Aluminium with insulation sleeves etc.Other assemblies and control logic as per the tender specifications. 7 Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured electric cable of 1.1 KV grade confirming to IS 7098 PART-I with upto date amended. 8 4 C X 25 sq.mm 9 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 10 4 C X 25 sq.mm 11 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing HDPE/ RCC/ HUME/ METAL pipe as required. 12 Upto 35 sq. mm 13 Erection, testing and comissioning of 5 Mtr.high G.I. OCTAGONAL flood light pole & bracket / channel with all accessories by providing and making reinforced M20 cement concretefoundation including excavation and refilling including positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 40 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable along with earthing to the pole complete, as required as per technical specifications. 14 Installation, testing and commissioning of LED Flood light fitting with all accessories on existing pole of 5 mtr height with bracket / channel, including supplying and drawing of 3core x 4 sq.mm. FRLS PVC insulated PVC sheathed flexible copper conductor cable from loop-in-loop-out box upto the individual streetlight fitting(s), connection etc. complete as required & as specified. 15 Providing and fixing of advance technology earth electrode earthing system fabricated from High Tensile steel rods(Cu bonded Earth electrode Rod technology) with SS Double Sided Clamp (175mm X 50mm x 3mm) & cavity between rods pressure filled with highly conductive non-corrosive crystalline material complete with chemically modified homogeneous earth enhancing compound (Loresco powerfil carbon based back fill compound 25 Kg) to treat the soil for lowering the effective ground impedancefor each earth pit to make it maintenance free andto minimize the ground voltage potential rise i/cexcavation of Eco friendly rust proof heavy duty weather proof polyethylene earth pit chamber suitable to accommodate earth electrode(254 mm Top, 330mm dia bottom & 260 mm height), prefabricated MSenclosure withcover plate all as required & conforming to(IS:3043 : 1987) duly CPRI/ERDA approved as required & as specified for Size : -Electrode rod dia = 17.2 mm Length of electrode rod = 3 Mtr 16 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 17 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 18 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 19 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asperthearchitecturaldrawingswith 18mmthickstoneslabover20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigmentofmatchingshadeincludingrubbing,curingandpolishingetc.all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Contract Date: May 25, 2026 Contract Value : 11.90 Lakh
Boards / Undertakings / PSU No of Bidders 11
14.
Drinking Water Supply and Sanitation #10279059 Price Bid
Tender For Rehabilitation Improvement And Basic Facility Of Parbati Dam District Dholpur. - 5.1.2Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 2 Dismantling doors, windows and clear story windows (steel or wood) shutters including chowhats, architrave and holdfastsetc. Complete and stacking 50 m lead of area 3 square meter and below 3 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 5 to 10 m depth 4 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 x 50mm x 16 gauge 5 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . WITH 225 mm sweep 7 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. withStainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 8 Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1.5 TR ISEER not less then 3.8 9 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for Superstructureincluding curing all leads of all construction materials including curing etc. complete. in cement sand mortar 1:4 10 Add extra over item No. 18 (b) for compaction in restricted area nearby structure or flanks by hand rammers or by pneumatic tampers. 11 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 10 to 15 m depth 12 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)By Mechanical Means: Grading- I (Using Screening Crushable type such as Moorum or Gravel)Using Screening Crushable type such as Moorum or Gravel 13 11.5.4Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 15 to 20 m depth 14 Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means 15 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 20 to 25 m depth 16 Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom 17 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. Beyond 25 m depth 18 Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8- 10 tonne capacity, finished to required level and grades.)(I)a Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour .Using VG-30 binder 19 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 20 Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder.(ii) Bitumen grade VG30 @ 4.50% 21 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.From 5 to 10 m depth 22 dismantling roofs with care including stacking of serviceable material and disposal of unservicable material within 50m lead for lime terrace 23 Supplying and lowering into holes and fixing of casing pipes of suitable diameter to enable drilling of minimum 48 mm dia grout holes. 24 dismantling stone slab roofing over wooden karries or RCC battens ( dismantling karries and battens to be paid for separately) including stacking of servicable material and disposal of unservicable material within 50 m lead 25 11.7Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grout after stage grouting including cost ofequipment, compressed air and etc. complete. 26 Dismanling old plaster or skirting , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead 27 11.8Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification. 28 Dismantling flooring with care including stacking of servicable material and disposal of unservicable material within 50 m lead for: cement concrete flooring 29 5.16.1Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 30 Supply and fixing of steel doors, with frame of hollow metal pressed section 105×60 mm as per I.S.I 1.25mm thick with double sheet shutter 1.00 mm thick M.S. sheet tospot welded and embossed with rib type design on both sides, front side vertical and back side horizontal and spot welded including hold fasts of (15×3mm), M.S. oxidized fittings such as butt hinges sliding door bolts, handles, tower bolts etc. complete in all respect as per drawing and specifications including applying priming coat of approvedsteel primer 31 11.10Conducting water intake test in test holes under pressure for determining permeability before or after grouting including cost of equipment and water etc. complete 32 Earth work in excavation in foundation trenches or drains including dressing of sides & ramming of bottoms , lift up to 1.5 m including taking out the excavated soil & depositing & refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within lead of 50 m : all kind of soils 33 11.9Grouting of drilled holes minimum 35 mm dia with or without packers with cement/ clay and or chemicals (in the form of slurry with water) in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weight of ingredients excluding chemicals to be considered ) with a working pressure upto 15 kg/Cm2 (Dry cement consumption) 34 Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level: M10 grade nominal mix (with graded stone aggregate 20mm nominal size (P.C.C. in foundation) 35 16.33Exploratory vertical drilling of bore holes 150 mm dia through all kind of soils with the adequate / suitable equipments, tools and tackles for depths mesured below existing ground level including mobilization, setting up boring rig, shifting of rig from 1 bore hole to another and demobilization of the same 36 Random Rubble Stone masonry for superstructure above plinth level one storey height above 30 cm thick walls in: cement sand mortar 1:6 37 16.32.3Boring NX dia (54.7 mm dia), hole with diamond coring bits including taking out of core and arranging etc. core in proper order in core boxes including cost of core boxes. as per relevant I.S. code of practice. These rates are including Mobilization & demobilization of Rig. In sand stone and harder variety of lime stone 38 Filling available excavated earth ( excluding rock) in trenches ,plinth side of foundation etc. in layer not exceeding 20 cm. in depth , consolidating each deposited layer by ramming amd watering including lead up to 50 m and with all lift 39 5.1.3Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum 40 Brick masonry in foundation and plinth with bricks of class designation 75 in: cement mortar (1:6) (1 cement : 6 coarse sand) , add extra for superstructure upto third storey 41 10.1.1Side shuttering including propping etc. complete (to achieve finish F 2 for :Block joints of foundation stilling basins buckets, aprons etc. (non -suspended horizontally laid massconcrete) 42 Providing and laying in position specified grade of cement concrete for RCC structural element upto floor three level including curing , compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of shuttering , centering and reinforcement for: Beams, suspended floors, roofs, girders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircase and spiral staircases : M20 grade nominal mix/design mix Desc/Location Nos L B H 43 9.8.3Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm 44 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of column etc up to plinth level 45 9.6.4Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm 46 P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto floor three level .: Hot rolled deformed bar (IS : 1139) 47 7.1.2Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:4 48 PLASTER (Ceiling) 6 mm thick. Cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) 49 8.13.2Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sandmortar 1:4 50 PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. 51 5.9.1Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respectNot exceeding 15cm 52 Painting with enamel paint of approvd brand and manufacture to give an even shade : Two or more coats on new work 53 18.17.2Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 54 Granding for roof water profing treatment with cement motor 1:4 (1 cement : 4 coarse sand) 2 inch thick 55 18.28.1.2Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458- 2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 56 Polished Blue kota stone flooring Skerting, Laid over 20 mm thick base of cement mortar 1:4 and jointed with Grey cement Slurry to match of the Shade of the Slab including rubbing and polishing complete for area of each slab from 2001 to 5000 sq. cm. 25 mm thick slab 57 11.19Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge 58 Providing brick kharanja in cement sand mortar 1:4 in square pattren over roof of ground floor (75 mm to 100 mm thick avarage) Add for if cement mortar 1 : 4 is used instead of lime sand mortar 1 : 2. 59 18.50Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/ brushing including chiseling and removing leached lime deposit and disposing off all the waste materialoutside adits in specified location as directed etc., complete with all leads and lifts. 60 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish 20 mm thick Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. 61 9.8.4Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sandmortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm 62 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4 ralthal, stone kharanja, lime terracing 90 mm avarage thickness [as per JAIPUR PRACTICE] with ceiling pointing in cement sand mortar 1:3 per specification for span:above 3.00 metre and upto 3.30 metre. 63 10.1.3Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 64 Providing and fixing T-iron frame for doors windwos and ventilators of mild steel tee-setions, joints mitred and welded with 15x3 mm lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 200 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butts hinges and screws and applying a priming coat of approved quality 65 10.9.2.2Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leadsand lifts using. Tor or ribbed bars (IS :1786-1985) 66 window:Providing and fixing Ms sheet double leaf doors shutter in angle iron frame 35x35x5 mm suitabilly digonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of engineer incharge. M.S. Sheet 20 SWG 67 10.9.1Labour charges for steel reinforcement including bending, binding, and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts. 68 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5 mm siutabilly diagonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chokhats: including two coats of anit-corrosive red oxide primer paint. M.S. Sheet 22 SWG 69 10.10.2Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc. 70 Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3 with suitable screw at not exceeding 150 mm distance 71 5.8.1Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicabletaxes and levies etc. complete in all respect Earth / Soil 72 Providing and fixing square bars or other flat welded to window ventilators etc. 10mm x 10mm 73 5.18.2.2(ii)Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of. at least 98% of Standard Proctor s density 74 Polished blue kota stone flooring skirting laid over 20mm thick base of C.M. 1:4 and jointd with grey cement slurry to match the shade of the slab including rubbing & polishing complete: for area of each slab from 901 to 2000 sqcm (a) 25mm thick slab 75 5.9.2Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respect Not exceeding 20cm 76 Providing & fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 77 5.10.1Beyond initial lead of 50 m & upto 250 m 78 Finishing wall with water proofing cement paint of approved brand & manufracture and of required shade to give an even shade including all scafolding new work (three or more coats) 79 5.30Supplying and laying sand of grade as per design requirement in required profile including all lead & lifts.This item is to be used only for laying filter / inverted filter 80 White washing with lime to give in even shade including all scaffolding on new work (three or more coats). 81 5.31.2Supplying and laying aggregate in layers and profile as specified including all leads & lifts.This item is to be used only for laying filter / inverted filterBroken ballast 20 to 40 mm size 82 P & F rigid PVC pipe (IS 4985 Mark) Class 2nd / (4 kg / sqcm) approved quality / Make including jointing the pipe with solvant cement rubber ring and lubricant 110 mm dia. 83 11.14Prepration of old masonry surfaces before laying of further masonry or concrete over it by cleaning the surface and mortar joints with brushing and raking finally, washing by compressed air & water under pressure 84 PVC bend 110 mm 85 37 mm thick shotcrete by wet mix process, applied with compressed air gun after chipping of defective concrete / masonry, racking the joints, cleaning of surface thoroughly with wet sand blasting after fixing of 9 gauge good quality rust free welded mesh of size 50 mm x 50 mm in TWO layers with anchors / clamps. After racking the joints clean the surface thoroughy by wet sand blasting, anchor the first layer of welded mesh in position and apply 15 mm cement concrete (1:2:1) by pressure gun and after hardening of first layer, anchor second layer of welded wire mesh, apply 22 mm thick cement concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively. 86 Pointing on stone masonry in lime sand mortar 1:2 (1 lime putty : 2 sand) : Raised and cut pointing 87 11.18Add extra over item No. 16 &17 for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level (upward or downward) 88 P & F unplasticized poly choride (UPVC) SWR pipe fitting type B for sciland waste discharge system ( IS : 13592: 1992 marked) of approved quality / make 110mm dia 89 12.30.3Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) Tefloncladded 90 P&F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS : 2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : size530x410 mm 91 12.40Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber sealinsertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 92 P & F WVC wash basin (Ist quality, I.S. : 2556 mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. pillar cock (IS : 8934 mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 450 mm x 300 mm 93 12.38Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete. 94 P & F G.I pipes (internal work) with G.I. fittings (IS:1239 mark) & MS clamps including cutting and making good the walls and floors : Exposed on wall A (i) 15 mm dia nominal bore 95 5.28.1Watering of earth including cost of carriage of water when source of water is up to 1 Km 96 Painting with enamel paint of approvd brand and manufacture to give an even shade : One or more coats on old work 97 12.39Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 98 P & F PVC storage tank (IS : 12701 marked indicating the BIS license No), of approved make with cover, 25 mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design : 300 litre capacity. 99 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height 100 P & F stop cock (IS : 8931 mark), superior quality & of approved make : brass 400 gm. 15 mm nominal bore 101 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.upto1.5m height 102 P & F looking mirrors with P.V.C. frame of approved (Atul, Modi Guard , Saint Gobin or equivalent) size 500 x 400 mm 103 18.13Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material 104 P & F flush cock/flush valve (IS 9758 mark) for WC of approved quality make : CP brass half-turn exposed 25 mm nominal bore. 105 12.37Oiling and greasing of Crest radial gates,Vertical Gates and Intake Service well Gates of Dam including all charges of man and material complete, which include cleaning of wire rope with petrol / diesel and applying Cardium compound to wire ropes, oiling & greasing etc complete as per direction of Engineer-in-Charge 106 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick insider plaster in cm 1:6 , finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr. inside size 300 x 300 mm depth up to 0.5 m cement cover with frame. 107 12.4Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator includingcost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tarepoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. 108 Construction of soakage well in all types of soil of approved drawing, top 90 cm. Portion in 450 mm thick masonry with cm 1:6, 80 mm thick stone slab covering, jointing of slab in cm 1:3, Ralthal, Kharanja 40 mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth with in a lead of 50 mtr. inner dia 90 cm & 10 to 12 mtr deep 109 11.13Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete. 110 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other lightshades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flushpointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category-A : Kajaria, Jhonson, Somani make 111 12.52.1.11Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb type of Size 75mm 35mm x 10 mm 112 Add extra over item No 7.6.1 and 7.6.2 for using 400x400mm size MAT finished tiles inplace of 300x300mm size 113 12.52.1.9Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb with brass clading type of Size 100mm 45mm x 15 mm 114 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. doors 115 12.49.2Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Materialfor vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm 116 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded incement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, ormetal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steelhandles and peg stay etc. as required.windows sidehung(openable) 117 5.33Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts 118 Distempering with oil bound washable distemperr of approved brand and manufacture to give an even shade including all scaffolding : old work (one oe more coats) including scrapping surface and necessary repairs (a) colour change 119 12.36Operation of vertical / radial gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer in-Charge, by providing sk illed & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam 120 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and includingscrapping and priming coat with cement primer 121 5.2.2Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Hard rock not requiring blasting 122 P & F bib cock (IS : 8931 mark), superior quality of approved make : Brass 400 grm, 15 mm nominal bore 123 18.1.2Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick 124 P&F sand cast iron (S.C.I.) Pipe (IS:1729 mark) of approved make in wall in floor with MS holder bat clamps in 10X10X10 cm. M15 grade concrete block joints filled with CM 1:4 with spun yard including cutting holes and making good the wall.150mm dia. 125 17.5.2Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 126 P&F SCI fittings (IS1729mark) in CM 1:4 spun yarn150mm w/o door Bend 127 5.2.3Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Phylite & other hard rock requiring nominal blasting 128 spray painting with flat wall paint of approved brand and manufacture to give an even shade : two oe more coats on new work including priming coat of distemper primer of approved brandand manufacture 129 11.2.1Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drillingincluding cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.Up to 5 m. depth 130 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 131 11.2.2Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.From 5 to 10 m depth 132 S&Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steelenclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure A attached with this BSR . 32 A, Four poleF following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according toIS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 133 2.9.2Cement OPC (in bags) 50 Kg in weight. As per IS 1489 and IS 8112 (excluding cost ofempty begs). 134 S&PP & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSRroviding & Fixing of ISO certified company made off load change overswitch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in thefollowing rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 A, Four poleFfollowing sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 6.4 mmthick 135 10.2Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 136 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure Aattached with this BSR 9 mm thick 137 11.1.1.1Drilling holes of 35 mm diameter for anchor rods.Upto 1.50 m. depth 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimumphase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR (a) 6 Amp to 32 Amp rating 139 5.35.3Supplying stone, spall and laying R. R. stone pitching, hammer dressed with packing ofvoids from small stones including all lead & lifts, in required profile of 23 cm thickness ( 5 % thickness tolerance) 140 Providing corrugated G.I. Sheet roofing fixed with G.I.J. or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60o) & excluding the cost of purlins rafters and truses, for class of sheets :1.60mm thick 141 11.1.2Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete 142 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Triple pole MCB 50/63 A rating 143 11.1.3Supply of Tor steel anchor bars of required diameter, length and shape at site of work complete. 144 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR (c) Double pole MCBS of 50 AMP to 63 AMP 145 12.7Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting ofhoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 way Metal door (single phase) 147 12.1.1Design, drawing, fabrication, supply, erection, testing and commissioning of Embedded parts consisting of sill beams, vertical tracks, vertical seal tracks, sealing frame, guide tracks/rails, wall plates, seal seats, anchors, anchor girders, yoke girders, tie flats, trunnion supports, rope and pulley supports etc. and any required necessary item, with all accessories as per relevant IS code, for all type radial gates/ Vertical lift fix wheel type sluice and Canal gates/Stop log gates including cost of all materials, machinery, labour, cutting,aligning, anchoring, welding, finishing, cleaning, tools and tackles, applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thicknessof 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., including packing & forwarding, transportation charges complete item, as per specifications and approved drawings 148 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (metal / Glazed )Distributio board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR 12 way Metal door (single phase) 149 18.49Under water videography of dam body & its appertunance i.e gates, under sluice, emergency gate grooves clearly showing location defect area or area of interest indicatingcondition from all possible angles and special focus on damaged portions complete in all respects upto the satisfaction of Engineer in charge. The work also includes supply of three sets of video in digital form and a depth wise report prepared in hard copy 150 Providing & fixing in position frame made out of MS angle (riveted or welded) finished with two coat of red oxide and enamel paint of following size as required 38*38*6 mm 151 12.8.1Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle, gate positionindicator, plumber block, couplings with all required accessories for operating Head/cross/escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts,including packing & forwarding, transportation charges for structural steel components and other materials. 152 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. systemlumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing 153 5.15.1.1Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all typessoils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 154 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole 100/300 mA sensitivity 40 A rating 155 7.1.3Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation includingcuring with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 156 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulationPVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parametersof product / work refer Annexure A attached with this BSR 1 *2.5 sq.mm 157 9.3.1Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing withrendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher brokenstone aggregate of maximum size upto;(For mix design Cement content considered 420 kg/ cum of concrete) 150 mm 158 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 1*6.00 sq.mm 159 7.10.2Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materialsincluding curing etc. complete. In cement sand mortar 1:4 160 Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron crosshead and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached with this BSR. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm 161 5.26Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. ifrequired including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete 162 Add extra over item No. 10.25 for providing and fixing CGI sheets in curved roofing 163 8.2.1Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm 164 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discomsstandard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 165 10.1.110.1 Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility ScaleSolar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR,showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed towithstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of more than 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in stringlevelmonitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive.The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.10.1.1 Solar panels up to 10 KW at a single location. 166 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure Attached with this BSR 30 Sqmm of (6+1) 2.59mm (Weasel) 167 16.12Hire charges of DGPS instrument with operator and staff for bench mark shifting, topography survey, command area survey, canal survey, dam survey etc. and collection ofdata, plotting the details and preparing digital map of area in layers, and developing contours where ever required as directed by engineer in charge; including supply of detailed drawingsin appropriate scale in soft copy & three sets of Hard copy complete in all respect. These rates are including all types of taxes applicable 168 Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR 169 16.14.1.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, develo ping L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) L-section of Dam/ Canal (ii) InPlain area - Levels for L-section to be taken at interval 30 meter. 170 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 2 LED Tube shape fixture for single rod 171 16.14.2.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, developing L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) X-section of Dam/ Canal(Total length of X-section shall be measured) (ii) In Plain area - Levels for X-section be taken at interval 5meter 172 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lidsuitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 173 16.10Grid survey at interval of 30 x 30 meter to conduct submergence survey with TS / DGPSinstrument and prepare 0.50 m interval contour plan and superimposing over khasra map including all ancillary works as described in specifications and conditions of contract. Note: Khasra map will be provided by Department Marking of existing FRL, MWL, MDDL contours and dam alignment. Prepare area-elevation and storage -elevation curves andtables. 174 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing 175 16.6.1Digitization of Jamabandi and providing excel sheet to the department Note: Jamabandi Register will be provided by Department 176 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ 177 16.6.2Digitization of Khasra map with details in layers and providing soft copy (acad file) Note: Khasra map will be provided by Department 178 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter& Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults,UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturershall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ wo rk , refer Annexure A attached with this BSR . 50 to 82.5 kva 179 5.10.4Add extra for each subsequent lead of 1 km or part there of beyond 5 Km 180 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr) 181 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii - Medium point (upto 6 Mtr) 182 11.5.1Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 183 Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height.In flats, tees, angles and channels. 184 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii - Long point (upto 10 Mtr) 185 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988)accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy /Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :on board 186 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 40A rating 187 P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 188 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirementslaid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 189 Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR . 190 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attached with this BSR 191 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI>70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 watt 192 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 4.8 mm thick 193 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brassterminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR 194 providing of 18mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 195 Chair type 7 {Revolving chair medium back, support backrest symmetrical lumber support, back cover mesh fabric) (inclusive all taxes) 196 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 197 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up theinterstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&Hspecification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete : Crusher broken Grade II (63-45 mm) 198 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specificationincluding all material, labour, machinery, lighting, guarding and maintenance of diversion 199 Chair type 4 {chair type with arms,frame type 4 legs,castors without (inclusive of all taxes)} 200 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fineaggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuousoperation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour,machinery, lighting, guarding and maintenance of diversion. PCC M-25 201 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be rovided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow raceability/authenticity. Fixture shall be IS 10322 Complianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures . (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted . All as per approved by Engineer In charge . for additional technical parameters of products/works . High Power LED Flood 202 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S tube 203 Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 4 meter 204 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work . Double arm overhang 205 providing of 24 mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 206 Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, inte gral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM must have type test certificate for wind tunnel test for high mast fixtures , complete in all respect .All asper pre approved by Engineer in charge ,for additional technical parameters of products/work. 16.0 Mtr HM(in 2section) 207 Labour charge for removing old wire ropes and fixing of new wire ropes with all accessories and T&P etc complete 208 oiling & greasing of gantry crane on Parbati Dam Which includes complete Removal of all old worn out & broken down parts, cables, connections etc complete checking of all copper wiring, all wiring & connections control panel , all switches etc complete with all material , labout, T&P and lead and lift complete in all respect 209 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approvedbrand or manufacture 210 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. : 80mm thick 211 Table type 3 (storage provided one side,length of table top-1200 mm, depth of table top-600 mm) 212 Providing sofa set(Frame covering fully upholstered, Total No of seats in sofa set -4, covering material for seat and back rest-leatherite) 213 Table type 5 (seating capacity - 8 seater, width in mm -1200, Length in mm - 2400mm, shape of table top Rectangular , height in mm - 750 mm ) (inclusive all taxes)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
16.
Defence #10003682 AOC
Tender For Demolition And Re-Construction Of Smc Building At Afs Yelahanka On Epc Mode; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX are prepriced by MES under Ser No. 2 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Site Clearance as listed in Schedule ‘A’ Part - II. 4 Lumpsum price worked out by the contractor for Road/Path/Hardstanding as listed in Schedule ‘A’ Part - III. 5 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - IV. 6 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. 7 Lumpsum price worked out by the contractor for “Fencing” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII 9 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII 10 Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – IX 11 Sch A Part - I : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF TWO STOREY (G+1)SMC BUILDING, AMBULANCE PARKING SHED AND DEMONSTRATION AREA INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. 12 SCHEDULE A Part- X (FITTINGS AND FIXTURES & MISC ITEMS) 13 ROADMaterial and labour for preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using HOT MARK by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4of MORTH specification,thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088Aand road marking shall done as per provisions contained in IRC-35-1997 complete all as specified and as directed. 14 FENCINGSupply and fix Stainless steel 304, 12 inch size each letter for Bilingual name board (Hindi-14 Nos letters and English-21 Nos letters) embedded in Granite on both gate complete all as specified and directed. 15 EXTERNAL WATER SUPPLYMaterial and labour for cutting existing 150mm bore water mains and inserting TEE 150mm x 100mm including necessary fittings, joints etc for connection of TEE complete all as specified and as directed. 16 Supply and fix Cast iron sluice valve flanged of class 1.0 PN, 80mm complete all as specified and as directed, 17 Supply and fix 80 mm dia cast iron body with flanged ends drilled ISI marked as per IS 14846:2000, PN 1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and as directed. 18 EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 19 Material and labour for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and directed. 20 Supply and installation , testing and commissioning of HT 11 KV, rated voltage 12 KV,630 Amp, 21 KA / 3 Sec outdoor type extensible internal arc 21 KA for 1 sec for Tank floor mounted with internal copper busbar, SF6 insulated completely motorized 4 way RMU consisting of 01 Nos VCB 630 Amps as incomer and 03 No 630 Amp VCB as outgoingSCADA compatible, over load and earth fault protection relaywith air insulated metering module (MFM for VCB feeders) all live parts busbar ,VCB connections of RMU shall be inclusive in one SF6 tank to avoid multiple inter connections SF6 tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel grand 304 min 2.5 mm thick having IP-67 degree of protection filled with SF6 gas has insulation with leakage rate less than 0.1% per year tested as per IEC 62271 200 I No fault passage indicator (FPI) required for complete unit manual welding or heremetic ceiling of tank shall be not accepted . The unit shall have front cable entry (suitable for termination of 1 hr x 3C 95.120/ 150 Sqmm cable) for easy of installation and shall have site replaceable bushing for easy of troubleshooting during break down. RMU should be completed with all accessories such as terminal boots, VPIS , cable supports , all front cable terminations , mechanical indications vacuum circuit breakersON/OFF, Manometer as per with IEC standards 62271200, 60056, 60129, 60265, 60298, 60420, 60529 & 60694 altitude of installation upto 1000 m as per IEC 60120bushing bolted type top monitored outside the tank for connections of external busbar also the outer includes shall cover the full length of the switchgear , to ensure IP3X + IP-54 protection for cable boxes the unit shall be internal arc proof 24 KA for 1 sec with AFLR classification tested and totally safe for human being. 21 The gas release and personnel safety from internal arc shall not dropped on plinth design the release of gas to be from the top the unit . So that even if the person is operating the unit opening the cover and there are personnel near the side of the RMU / plinth top release will ensure their safety. The hot gas release in case of an internal arc, in No of case should be from any side or bottom of the unit as the same if unsafe for operating personnel / pedestrian or general public. Bidder shall provide type test report to be prove compliance to the internal arc fault IAC-AFLR as per IEC62271-200 internal arc testing shall be done with enclosure door in open conditions , with switching devise in operations mode as per specified standard RMU.(a) 01 Nos Incoming 630 AmpsVCB,motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 Nos Outgoing 630 Amps motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.(c) Bus connected PT unit-01 No for metering consisting of following:- (i) Type M : Air insulated metering module 12 KV, 630 A 21 KA for 3 sec.(ii) 3 voltage transformers of the ratio 11KV/1.732/110V/1.732.25VA class 1.0 with HT fuses on primary side and MCB on secondary side. 22 (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVAR.(iv) 1 LED bulb for illumination. (v) 1 Space heater with thermostat. (vi) 1 RYB Phase indicator. (vii) 1Cable support bus bar, stand for 3 Way unit, 1 Manometer & 1 Preparing Handle. (viii)1 Set bushing for external busbar connection along with bus bar cover & sleeved bus bars for coupling. (ix) 2x12 V Battery with charger of suitable burden for motor operation, input 230 V AC & output 24 V DC.(d)Capacitive Voltage indicator fixed type VPIS 9-15 KV. (e) Necessary inter locking arrangement for safety and operation. (f)One No Operating handle for manual operation. (g) PCC 1:2:4 type B1 using 20mm graded stone aggregate for foundation and bus duct of cable for RMU as per recommendation of manufactures & as directed by Engineer-in-charge. (h) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (j) Above switchgears shall confirm to all relevant IEC/IS standard.(k) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be required to dismantle during manual operation.(l) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable.(m) Minimum 3 Module should be accommodate in one tank to avoid multiple coupling at site. (n)Having following additional facilities:-1. Trip circuit supervision. 2. Disturbance recorder. 3. Event log with date and time.4. Measurement and control feature. 23 (o) Current Transformers (CTs) of dual ratio 50/25-5A of 15 VA output, accuracy class 1.0 for metering instrument and 5P10 for 15 VA accuracy for over current and earth fault protection - sets of 03 Note:-(i) Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.(ii)Cable compartment shall be provided at the front side with front bolted type box covers providedwith an inspection window forenabling operator to have visual inspection without operating cover in live condition for all incoming and outgoing RMU panels.(iii) Complete with internal and external connection with each other or as per ground requirement.(iv) Drawing and Design drawing shall be submitted for approval of Accepting Officer before placing Order.Following additional equipment delivered separately or mounted in respective panel.(i) Cable support bars, standard for 4-Way unit.(ii) Manometer.(iii) Operating handle. 24 Supply and fix 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required andall as specified and directed. complete accessories as required complete all as specified and as directed. 25 Supply and fix street light fitting 72 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection including GI Bracket of suitable size required for fixing LED light on pole along with nut and clamp complete all as specified and directed.Note :- Rates quoted by contractor are deemed to be inclusive of 3 core cable pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified. 26 Supply and fix pole box of size 450x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp02 Nos with nuts, bolts and washers complete all as specified and as directed. 27 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point including testing on completion complete all as specified and as directed.Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. including testing on completion complete all as specified and as directed. Note :(i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode.The earth pit and pipe for watering shall be provided in slanting manner.The unit rate include for GI pipes, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item. 29 Supply, installation, commissioning and testing of feeder pillar board Kiosk type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proofand compartmentalizedMain L.T Panel(CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 900 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.)Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators.All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves ofcoloured coded red, yellow, blue & black. Power & Control Wiring withCopper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Platform for the feeder pillar board with PCC 1:2:4type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minimum 100mm all around the feeder pillar board with following :- 30 (a)ACB 415 Volts, 630 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release -01 No.(I/C)(b) MCCB 415 Volts , 250 Amp 4P , 36 KA ,microprocessor release - 01 Nos (c)MCCB 415 Volts , 160 Amp 4P , 25 KA ,microprocessor release - 02 Nos(d) MCCB 415 Volts , 125 Amp 4P , 25 KA ,microprocessor release - 02 Nos(e)MCB415 Volts , 32 Amp 2P , 10 KA ,microprocessor release - 02 Nos(f)Voltmeter 0-500V digital type with selector switch 96mmx96mm square flush mounted- 01 No.(g)ampere meter digital type of size 96mmx96mm flush mounted CTs operated including CTs 0-630A with selector switch-01 No.(h) LED type/Neon type indicating lamps panel mounting type RYB-03 Nos.(i)fine wiring with single core PVC insulated conductor FLRS wire of suitable size copper conductor cable,thimble, lugs etc for instruments/indicating lamps-01Job. 31 Supply, fixing, testing & commissioning of LT panel board of size 1.1x1.1x.5 Mtr,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closedAluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltmeter 0-500 Volts, CTs of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc The bottom portion of enclosure shall be minimum 100 cm above ground level of legs of angle iron ). 32 (a) Copper bus bar capacity 900 Amps for Phase-R-Y-B-3 Nos &neutral -1 No(b) ACB FP 36 KA 630 Amps- 1 Nos(I/C) (f) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-630 Amps (g) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V(h) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder 33 Supply and fix Post top light of capacity 45Watt offering excellent uniform illumination and aesthetic in one go , made up of pressure die cast aluminium body and open PC Cover, IP 66 and IK-07 rating suitable for tall amid varied environmental conditions and for pole of dia 76mm colour temp 3000K complete all as specified and directed. 34 Supply and fix LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 9W, 220V, 50 Hz CCT- 3000K, 800mm Complete all as specified and as directed. 35 Supply, erection, testing and commissioning of 16M high mast shaft in two section suitable for 44m/sec wind speed along with head frame, luminaries carriage suitable for 8 luminaries in symmetrical arrangement and other accessories manufactured in factory including Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaries & MCB in base compartment are not included and are a part of installation) complete all as specified and directed by the Engr-in-Charge. 36 Supply of fix single dome LED type dome aviation obstruction light complete all specified and directed by Engr-in-Charge. Make : Bajaj Cat No : BGAV302LED or its equivalent in make specified in PS. 37 Supply and fix foundation bolts 04 Nos 24mm dia 850mm length, manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 38 Supply and fix LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed by Engr-in-Charge. 39 DG SETSupply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 320 KVA, 3 phase 0.8 power factor, 50 Hz,developing 434 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Yelahanka and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration andincluding the following accessories :-Make : Kirloskar / Ashok Leyland/ Ruston/Cummins 40 (A) Alternator :-Synchronous alternator rated at 320 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-(a)+-1% voltage regulation (max) in static conditions.(b)IP: 23 protections with class ‘H’ insulation. · (c)Permanent lubricating bearing. · (d)Permissible overload of 10% for one hour in 12 hours of operation.(B) Diesel Engine: - Adquate capacity of Diesel engineliquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Liquid pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential typev) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hosesvi) Lub oil System :- Lubricating oil filter,Lubricating oil pumpvii) Air Intake System :- Air intake Manifold,Air cleaner dry typeviii) Governer : Electronic typeix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length fromself starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. 41 xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure,high coolant temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Base frame is fabricated either in ISMCor in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete seti.e. along with canopy, engine and alternator.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines.xviii) 2 No battery of 12 V in charged condition with its leads. C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. 42 (i)Manufactured by OEM suitable for 320 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistancefoam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be < 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade.D) Control Panel :- Control panel shall befabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.(ii) Instrument fuses and control wiring. (iii) Indication lampsset for running and load on.(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. 43 E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. F) Civil Works :-All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint workand related foundationsfor panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.The contractor shall arrangeartificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system toachieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved fromEngr-in-charge/GE before placing final order to the manufacturer.vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set. 44 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion.Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 45 REFRIGERATION & AIR CONDITIONING:-Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star ratingAs perBEE guidelines and ISEERValue not less than 3.90 for air conditionerof capacity 1.5 TR includingall specified and directed by Engr-in-Charge. 46 Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating as perBEE guidelines and ISEERValue 3.95 for air conditionerof capacity 2 TR complete all specified and directed by Engr-in-Charge 47 Supply, fixing, jointing and testing copper tubing with nominal diameter1-1/4 inch ofthickness not less than 1.2mmfor liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 48 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 49 Material and Labour for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enameled black paint complete all as specified and directed by Engr-in-Charge. 50 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 51 HAND DRIER AND SOAP DISPENSERSupply and fix automatic hand drier machine suitable for single phase supply 230 Volts, 50 Hzwith ABS plastic body complete all as specified and directed. 52 Supply and fix automatic soap dispenser , 220 V , 50 Hz complete all as specified and directed. 53 UPSSupply, installation, testing and commissioning of online UPS of 30 KVA with isolation transformer and static bypass switch, Authomatic transfer switch of capacity 100 Amps 4 Pole) alongwith required sealed maintenance free batteries and batteries (12V 100 AH-32 Nos)with stand for backup of 30 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete as required.I/P Voltage 360 V - 480 VNominal frequency - 50 HzFrequency range for online operation 45-50 HzI/P current range - 36A - 29AO/P voltage 415 VO/P current - 42A 54 LIGHTNING PROTECTIONSupply & fix Special standing seam fixure Clamp for Air terminal on Metal Structure -Site specific all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICT54 or its equivalent in approved make. 55 Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIAT02JIM04 or its equivalent in approved make. 56 Supply & fix 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIDC01 or its equivalent in approved make. 57 Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make JEF Cat No JIDC01 or approved by E-in-C Branch/CE Southern Command.Make : TIRUMALA/JEF Cat No JICL07 or its equivalent in approved make. 58 Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICL49 or its equivalent in approved make. 59 Supply & fix Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP02 or its equivalent in approved make. 60 Supply & fix Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JISP01 or its equivalent in approved make. 61 Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP05 or its equivalent in approved make. 62 Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connectRound to Flatconductor all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No TL06 or its equivalent in approved make. 63 Supply & fix Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No R14.CB1.SS01.E06 or its equivalent in approved make. 64 Suply & fix25 X 6 mm size GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding all as specified and directed by Engr-in-ChargeMake : TIRUMALA/JEF Cat No DW16 or its equivalent in approved make. 65 Supply & fix Holder -GI for fixing 25x 6 mm GI Strip complete all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFNo JICL08 or its equivalent in approved make. 66 MEDICAL GAS PIPE LINE SYSTEMSupply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :12mm X 0.7 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 67 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :15mm X 0.9 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 68 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :22x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 69 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :28 x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 70 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor oxygen complete all as specified and as directed. 71 Supply and fix Humidfier bottle forBPC flow meter complete all as specified and as directed. 72 Supply and fix Metal body BPC flow meter (0-15 ltrs ) adult complete all as specified and as directed. 73 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor vacume complete all as specified and as directed. 74 Supply and fix 600 ML VACUUMEJar complete all as specified and as directed. 75 Supply and fix Vacummer regulator complete all as specified and as directed. 76 Supply and fix Zonal valve box completeset withisolationballvalve and gauge (Aluminium framewith MSBox for2services (15mmx 22mm) complete all as specified and as directed. 77 Supply and fix Microprocessor based line pressurealarmdigitaltypefor2 gas serivce(oxygen / vacumm) complete all as specified and as directed. 78 Material and labour for perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar / Super Steel Industry / SV metals Pvt Ltd 79 DEMOLITION OF EXISTING BUILDINS (E/M ITEMS)Taking down unserviceble submain wiring any size /any cap complete all as specified and as directed. 80 Taking down unserviceble DBs any size / any cap complete all as specified and as directed. 81 Taking down unservicebleMCB SP/SPN any size /any cap complete all as specified and as directed. 82 Taking up old earthing any size/any type complete all as specified and as directed. 83 Takingdown earth strip/wire any size/any type complete all as specified and as directed. 84 Dismantling and taking out carefully GI pipe 25mmdia including earth work/RCC and complete all as specified and directed Engr -in-Charge.
Contract Date: May 26, 2026 Contract Value : 11.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
17.
Civil Aviation #9993316 AOC
Bids Are invited for Making In Field Measurement Of Intensity - Making Infield Measurement Of Intensity, Beam Spread And Orientation Of Lights For Inset And Elevated Type, Runway Edge Threshold Runway Endsimple Approach Lights Papi Etcairfield Ground Lights By Using Vehicle Mounted Mobile Testing Equipment System, Portable Photometric Reader And Replacement Of Defective Components Found While Photometrylike Filter Lens Inner And Outer Reflector Lamp Holder Lamp Etc And Submission Of Reports Etc As Per Requirement Of Civil Aviation Requirement Carsection4 Series B Part I Complete As Required. Consumable Spare Materials Shall Be Supplied By Aai , Supply Of 200 Watt Bi Pin Papi Halogen Lamp - Supply Of 200 Watt Bi Pin Papi Halogen Lamp For Papi As Required. Ama Make , Supply Of 105 Watt Bi Pin Halogen Lamp - Supply Of 105 Watt Bi Pin Halogen Lamp With Ceramic Base Suitable For Inset Type Fitting As Required. , Supply Of 150 Watt Bi Pin Halogen Lamp - Supply Of 150 Watt Bi Pin Halogen Lamp Suitable For Elevated Type Fitting As Required. , Supply Of 200 Watt Bi Pin Halogen Lamp - Supply Of 200 Watt Bi Pin Halogen Lamp Suitable For Elevated Type Fitting As Required. , Supply Of Filter Green Colour - Supply Of Filter Green Colour Suitable For Elevated Type End.Threshold Light Fittings Halogen Type As Required. , Supply Of Filter Yellow Colour - Supply Of Filter Yellow Colour Suitable For Inset Type Runway Edge Light Fittings Halogen Type As Required. , Supply Of Original Reflector For Papi Units - Supply Of Original Reflector For Papi Units Sourced From The Oem As Required. Make Ama Model Mk Iii. , Supply Of Outer Glass Runway Edge Light - Supply Of Outer Glass Suitable For Existing Elevated Type Runway Edge Light Glf Fittings. Make Vardhaman , Supply Of Outer Glass Unway Approach Light - Supply Of Outer Glass Suitable For Existing Elevated Type Runway Approach Light Glf Fittings.Make Ama. , Supply Of Outer Glass Runway Edge Light Ama - Supply Of Outer Glass Suitable For E
Contract Date: Ref. Documents Contract Value : 10.46 Lakh
Boards / Undertakings / PSU No of Bidders 6
Contract Date: Ref. Documents Contract Value : 22.00 Lakh
Government Departments No of Bidders 5
20.
Civil Aviation #9873616 AOC
Tender for Photometric Testing Of Agl System Including Consumable Spares At Dr. Babasaheb Ambedkar Intl. Airport, Nagpur. , A). Carring Out / Making In-Field Measurement Of Intensity, Beam Spread, Orientation, Chromaticity, Luminous Factor, One Time Field Alignment Setting For Inset / Elevated Type Approach, Inset / Elevated Type Runway Edge, Elevated Runway End, Inset / Elevated Type Threshold, Papi Airfields Ground Lights, By Using Vehicle Mounted Mobile Testing Equipment System, Frame Reader, Submission Of Test Reports Etc As Per Requirement Of Icao / Civil Aviation Requirement (Car) Section-4 Aerodrome Standard & Licensing Series B Part - I, Technical Specification Etc. Complete As Required. , B). Supply Of Following Glf Spares To Suit The Existing Installation And As Per The List Of Approved Makes, And The Material Supplied Should Be In Confirmity Of Latest Aai / Icao Specifications. , 200 W 6.6A Bi-Pin Halogen Lamp For Aun And Apn Fittings And Papi , 45W 6.6A Bi-Pin Halogen Lamp For Aln And Ald Fittings , Bi-Pin Lamp Holder For 200W & 45W 6.6Amp Halogen Lamp , 3600 Inner Clear Lens For Runway Fitting. , 3600 Outer Clear Lens For Aun Runway Fitting. , 200W 20A/ 6.6A Or 6.6 Amp/6.6A Isolating Transformer , 105 Watt Halogen Lamp For Inset Fitting (Ocem Make) , Clear Speader Lens For Apn Approach Fitting With Gasket & Screw. , 180⁰ Filter - Red For Ama Aun Runway Fitting. , Reflector For Approch Lights Of Ama Make. , Green Spreader Lens For Apn Threshold Fitting. , Note :- All Rates To Be Quoted By Bidder Should Be Exclusive Of Gst
Contract Date: Mar 24, 2026 Contract Value : 24.11 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
Contract Date: Mar 03, 2026 Contract Value : 32.87 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Uttar Pradesh View Result →
23.
Defence #9605513 AOC
Tender For Provision Of High Mast Light At Asce Raiwala At Raiwala Mil Stn; 1 Supply, installation, commissioning and testing ofHigh mast made up of galvanised special steel conforming to IS, ASTM- A- 572/BN -EN -10025 continuously tapered 12 sided polygonal cross section suitable forlighting system. it shall be suitable for wind speed as per IS-875, Part- 3, 1987 double section of length approximately 12.5 meters to sustain as arising wind speed as per is 875 . An opening door shall be provided at the base that shall access to equipment installed in it and including providing of double drum winch & cable Plug and socket, double lock paddle, raising & lowering mechanism, lantern carriage ring suitable to carry 06 Nos LED light of wattage above 100 to 200 watts, whinch head frame, torque motor, limitor switch, cable trailing whinch, aluminium Pulley, having three point suspension system with stainless steel wire rope AISI 316 grade, 6mm dia 97/19 construction in and including suitable terminal box shall be provided at base compartment of high mast for terminating incoming thick glass and accessories all as specified and directed connected electrically from LT feeder pilllar box to avaiation lights of suitable length of size 2.5 sqmm 3core industrial, copper flexible cable in and including providing of lightning protection spkie complete all as specified and directed.Note: 1. The contractor will make the high mast function in all respect if anything missed out, the contractor shall provide the same without any extra cost or claim to the department.2. The contractor shall submit warranty of material for one year from the date of certified date of completion.3. The flood light suitable to fix high mast measured and paid separately (a) Excavation, returning and filling in excavated soil, removal of surplus soil from site and depositing upto 10 meter in low laying area as directed by Engr-in-charge at site(b) M&L for construction of foundation for 12.5 meter high mast considering the soil load bearing capacity 10 ton/sqm (the contractor shall submit the OEM foundation drawing with complete details for approval by the Engr-in-charge before progressing the work at site as per manufacturer proposal)(c) Providing of suitable size and length of cable from terminal block in base of High mast upto LED light with the provision of rolling winch which can be operatable at the time of taking down of light carriage from top to bottom.(d) LT Panel having incoming MCCB, outgoing MCCB/MCBs, time switch, contactor, indicator, voltmer suitable for controlling of electric supply of high Mast as per manufacturers design.(e) Aviation obstruction light, yellow painted die-cast aluminium alloy housing LEDlights , heat resistent clear thick glass and accessories all as specified and directedconnected electrically from LT feeder Pillar box to aviation lights of suitable length of size 2.5sqmm, 3 core industrial, copper flexible cable in and including providing of lightening protection spike complete all as specified.Note : 1.The contractor will make the High Mast functional in all respect, if anything missed out, the contractor shall provide the same without any extra cost or claim to the department 2. The contractor shall submit warranty of material forone year from the date of certified date of completion3. The Flood light suitable to fix high mast measuread and paud separately in itme of schedule. 2 Supplyand fixing 200 W LED flood lights, IP 66 & IK07 protected, housing made of powder coated single piece pressure die cast aluminium with heat dissipation housing with toughened glass cover and secondary lens on each LED & should be SMD type. The System Luminaire efficacy >= 120 lm/watt with High power LEDs is to be used and potted driver must be potted & has a unique BISR number with input voltage AC 120 V to 270 V AC with High voltage Cut off @ >= 300 V AC and auto resetting safety Input Frequency 50 Hz ±3% , Power factor > 0.95 driver Efficiency > 85 %, THD (I) < 10 %, humidity 10 % to 90 % RH, CRI >70, Working Temp -10 C to 50 C. The Luminaire shall be BIS certified and T.C certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70 % lumen maintaned and CCT 5700 K+335K. Surge protection shall be min>= 4 KV internal and min 10 KV external.Note-: The manufacture should provide warranty of street light for 2 years. 3 Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground. (earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by32* 6 mm strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire up to 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge.Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid separately under relevant items 4 Supply and laying ,fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board,insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 16 Sqmmsqmm 4 core withall as specified and directed. by Engr-in-charge. 5 Excavation in trenches in any type of soil and n.exc 1.5 m wide and n.exc 1.5 m in depth for ,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed. 6 Returning, filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soilcomplete all as specified and directed. 7 Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 mabove the starting point, complete all as specified and directed. 8 M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid. 9 Material and labour for cable protection with sub class ‘B’ bricks old size, laid dry, flat over sand cushining of cable, perpendicular across the cable in trenches complete all as specified and as directed. 10 Supply and fixingin repair GI tubing light grade 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under load etc for cable protection complete all as specified and directed. 11 Supply and fixing 24 W solarstreet light all in one with high efficiency mono crystalline solar PV module LiFePO4battery of capacity 12.8 V, 12 Ah with inbuilt BMS technology, MPPT charge controller, aluminium extruded body IP65 with serviceable battery compartment high efficiency LED for optimising battery autonomy complete including 6 meter 50 mm GI Pipe pole with excavation, foundation with PCC etc all as specified and directed. Make-: Bajaj / Havells/Surya/Crompton
Contract Date: Dec 30, 2025 Contract Value : 4.24 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
24.
Educational and Research Institute #9587545 AOC
Tender For supply of Tools & Equipment Of Fitter Trade -Safety goggles. Drill twist straight shank Drill twist Taper shank Glass magnifying Machine Reamer parallel (Helical flute) Pipe wrench Wheel dresser (One for 4 units) Star/Dresser with Holder Sleeve drill Morse Knurling tool (Diamond, straight & Diagonal) Indexable boring bar with inserts Dowel pin ( straight) Standard Tap screws Lapping plate Medium carbon Heat treated alloy steel Metric Studs and bolts along with nuts display) of standard length (May be manufactured in-house) Caps screws Drill gauges Slip-on Forged steel Flange Bolt & Nut with washer (May be manufactured in-house) Pulleys (for V-belt or Flat belt) V-belt and Flat belt Packing gasket Washer, clutch, keys, jib, cotter & circlip Bearing different types Trammel Pocker. Mallet. Aviation Snips straight Cut Snip bent Left Cut Carbide Wear Block. Lathe tools H.S.S. tipped set. Lathe tools bit. Lathe tools bit. Lathe tools bit. Arm strong type tool bit holder. Arm strong type tool bit holder. Arm strong type tool bit holder. Stillson wrenches Pipe cutter wheel type. Straight edge steel Spirit Level metal Type - 2 Stud Extractor EZY - out Universal scribing block. Angle plate Taps and dies complete set in box. Taps and dies complete set Interchangeable ratchet socket set Hand Reamer set (Tapar pin straight flute) Adjustable pipe die set BSP Torque wrench (Standard/Ratchet type) Pipe threading die with handle Lifting sling Bearing extractor Pulley extractor Stake hatchet with Leg. Stake grooving. Gauge snap Go and Not Go Gauge plug Gauge telescopic set. Pipe bender machine spool type with stand manually operated. Adjustable pipe chain tonge to take pipes Wooden handle forged Soldering Iron copper bit. Drill chuck with key Power tools for fastening Cast Iron Globe Valve (Flanged type) C.I. Sluice / Gate valve (flanged type) Stop cock
Contract Date: Jan 31, 2026 Contract Value : 1.08 Crore
Boards / Undertakings / PSU No of Bidders 2
25.
Public Administrative Department #9550903 AOC
Bids Are Invited For Steel Rule , Try Square , Caliper Inside Spring Type , Caliper Hermaphrodite Spring Type , Caliper Outside Spring Type , Divider Spring Type , Scriber , Centre Punch , Screw Driver , Chisel Cold Flat , Hammer Ball Peen With Handle , Hammer Ball Peen With Handle , File Flat Second Cut , File Flat Smooth , File Half Round Second Cut , Hacksaw Frame Fixed Type , Safety Goggles , Dot Punch , Steel Rule Graduated Both In Metric And English Unit , Straight Edge Steel , Spirit Level Metal , Stud Extractor Ezy Out , Combination Set , Micrometer Outside , Micrometer Outside , Micrometer Outside , Micrometer Inside With Extension Rods , Vernier Caliper , Vernier Height Gauges , Vernier Bevel Protractor , Screw Pitch Gauge Metric , Wire Gauge Metric Standard , Surface Plate Granite With Stand And Cover , Marking Table Mild Steel , Universal Scribing Block , V Block Pair With Clamps , Angle Plate , Punch Letter Set , Punch Number Set , Portable Hand Drill Electric , Drill Twist Straight Shank , Drill Twist Taper Shank , Taps And Dies Complete In Box , Taps And Dies Complete , File Knife Edge Smooth , File Feather Edge Smooth , File Triangular Smooth , File Round Second Cut , File Square Second Cut , Feeler Gauge , File Triangular Second Cut , File Flat Second Cut Safe Edge , File Flat Bastard , File Flat Bastard , File Swiss Type Needle , File Half Round Second Cut , File Half Round Bastard , File Round Bastard , File Hand Second Cut , Wire Brush , Oil Can , Pliers Combination Insulated , Wooden Handle Forged Soldering Iron Copper Bit , Blow Lamp , Spanner Double Ended , Spanner Adjustable , Interchangeable Ratchet Socket , Double Ended Tubular Box Spanner With Tommy Bar , Glass Magnifying , Clamp Tool Maker , Clamp C , Clamp C , Hand Reamer Taper Pin Straight Flute , Machine Reamer Parallel Helical Flute , Scraper Flat , Scraper Triangular , Scraper Half Round , Chisel Cold Crosscut Diamond Point. , Chisel Cold Flat , Chisel Cold Round Nose , Drill Chuck With Key , Pipe Wrench , Pipe Vice , Adjustable Pipe Die Bsp , Wheel Dresser , Machine Vice Swivel Base , Machine Vice Swivel Base , Sleeve Drill Morse , Vice Bench , Bench Working , Almirah , Lockers With 8 Drawers , Metal Rack , Instructor Table , Instructor Chair , Black Board With Easel , Fire Extinguisher , Fire Buckets , Machine Vice , Wing Compass , Hand Hammer With Handle , Torque Wrench , Power Tools For Fastening , Different Profile Gauges , Knurling Tool Diamond Straight Diagonal , Indexable Boring Bar With Inserts , Machine Maintenance Manual For Lathe Pedestal Grinder Drill Machine Power Saw , Temperature Gauge , Dowel Pin Straight , Standard Tap Screws , Lapping Plate , Medium Carbon Heat Treated Alloy Steel Metric Studs And Bolts Along With Nuts , Caps Screws , Drill Gauges , Cast Iron Globe Valve Flanged Type , C I Sluice Gate Valve Flanged Type , Stop Cock , Slip On Forged Steel Flange , Pipe Threading Die With Handle , Jigs Fixture , Pulleys For V Belt Or Flat Belt , Damaged Old Spur Gear , V Belt And Flat Belt , Packing Gasket , Washer Clutch Keys Jib Cotter Circlip , Hollow Punch , Drill Drift , Bearing Different Types , Lifting Sling , Bearing Extractor , Pulley Extractor , Trammel , Pocker , Prick Punch , Mallet , Aviation Snips Straight Cut , Flat Headed Hammers With Handle , Planishing Hammer , Snip Bent Left Cut , Stake Hatchet With Leg , Stake Grooving , Slip Gauge As Johnson Metric , Gauge Snap Go And Not Go , Gauge Plug , Gauge Telescopic , Dial Test Indicator On Stand , Sine Bar , Dial Vernier Caliper , Screw Thread Micrometer , Depth Micrometer 0 25 Mm , Vernier Caliper Digital , Digital Micrometer Outside , Comparators Gauge Dial Indication With Stand And Bracket , Engineer Try Square Knife Edge , Surface Roughness Comparison Plates , Digital Vernier Caliper , Vernier Bevel Protector , Carbide Wear Block , Lathe Tools Hss Tipped , Lathe Tools Bit , Lathe Tools Bit , Lathe Tools Bit , Arm Strong Type Tool Bit Holder , Arm Strong Type Tool Bit Holder , Arm Strong Type Tool Bit Holder , Pipe Wrerch , Pipe Cutter Wheel Type , Pipe Bender Machine Spool Type With Stand Manually Operated , Adjustable Pipe Chain Tonge To Take Pipes , Adjustable Spanner , Ss And Sc Centre Lathe All Geared With Minimum Specification , Pillar Type Drilling Machine , Drilling Machine Bench , De Pedestal Grinding Machine , Transformer Welding , Welder Cable , Lugs For Cable , Earth Clamps , Arc Welding Table , Oxy Acetylene Gas Welding Equipment , Gas Welding Table With Positioner With Fire Bricks , Welding Torch Tips Of Different Sizes For Oxy Acetylene Gas Welding , Gas Lighter , Trolley For Gas Cylinders , Chipping Hammer , Gloves Leather , Leather Apron , Spindle Key For Cylinder Valve , Welding Torches , Welding Goggles , Welding Helmet With Coloured Flame Retardant Glass , Tip Cleaner , Compressor Unit , Pneumatic Trainer Kit , Pneumatic Workstation , Carrier For Mounting Components Such As Pb And Relay Boxes , Cut Section Model For Pneumatic Components , Hydraulic Trainer Kit , Hydraulic Workstation , Cut-Section Models For Hydraulic Components Total Quantity : 2103
Contract Date: Ref. Documents Contract Value : 53.42 Lakh
Government Departments No of Bidders 9
Uttarakhand View Result →
26.
Defence #9547066 AOC
Bids Are Invited For 50W Fm Transmitter , Two Bay 2 Dipole Antenna , Rf Cable Rf Co Axial Cable 50 Meter With N Connector At Both End , 9 Ru 19 Equipment Rack For Transmitter , 100W Dummy Load With Mathing Transformer , Manual Change Over Panel With 3 Nos Of Patch Cord For Switching Between Main And Standby Transmitter , 10 Band Fm Audio Broadcast Processor Internet Streamer With Iphone Android Application , Supply Installation Testing And Commissioning Of 30 Meter Self Supported Tower On Ground With Foundation Erection Galvanizing Earthing Lightning Arrestor Aviation Light , Monitor 50 W , 16 Channel Analog Audio Mixer , Rj Condenser Microphone , Desktop Audio Work Station Gen 16Gb 1Tb 250Ssd Win 10Pro Year 18 5 Tft , Two Channel Usb Soundcard , Table Top Stand , Flexible Microphone Stand , Headphone , Playout Software With Logger , Dynamic Cardioid Microphone , Hand Held Recorder , Audio Distribution Amplifier 1 Stereo Input And 6 Stereo Output , Headphone Distribution Amplifier 1 Stereo Input And 6 Stereo Output , Studio On Air Light , Digital Watch , Single Channel Telephone Hybrid , 15 Kva Genr Set With Complete Accessories Incl 90M Power Cable , 15 Kva Stabilizer , Security Led Lights , Junction Box Having 6 Nos Of Microphone And 6 Nos Of Headphone Facility , Misc Installation Material Like Audio Cable Connector Etc For The Installation Of Above Mention Equipment , Installation And Commissioning Work To Make The Crs Fully Functional Include , Recording Studio 12X12x10x10x10 4X10 540 , Wooden Sound Proof Door , Observation Window , Electrical Works , Production Table To House The Console Size 7X3 , Transmitter Room Table Size 3X3 , Revolving Chairs , Carpet , 1 5 Ton Ac , 5 Kva Ups , Earthing , Heat Radiator , License , Content Creation , Monthly Remuneration Total Quantity : 753
Contract Date: Ref. Documents Contract Value : 43.35 Lakh
Government Departments No of Bidders 4
27.
Defence #9528620 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date: Feb 11, 2026 Contract Value : 59.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
28.
Drinking Water Supply and Sanitation #9460337 Technical Bid
tender for Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply Works Such As Wtp Rcc Oht Zps Cwr Cum Pumping Station Rising Main Feeder Main, BARUASAGAR NAGAR PALIKA PARISHAD REORGANIZATION WATER SUPPLY SCHEME UNDER- AMRUT 2.0, DISTT. JHANSI Sl. No. Item Description 1 CIVIL WORK 2 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for Design and Drawing, Supply of all materials, labour, T&P etc. required for construction,of specified capacity (3.6MLD) of WTP based on 20 Hrs. operation (3.6MLD + 25%) extra over loading capacity includinginlet chamber, aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, sludge handling unit and recycling of collected water from sludge etc. complete,All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping and other campus development works, rain water harvesting, etc. all required works complete as per the direction of Engineer-in-Charge.The WTP shall be fully automatic based on PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring system. 3 For water works compound Construction of Bituminious approach road including preparation of subgrade. 4 Earth filling inside the water works campus. 5 Cutting of bushes, removing garbage form w/w site and dewatering of sub soil water at wtp & including maintinance of existingintake well Painting of intake well and existing water works campus 6 CONSTRUCTION OF SUMP-CUM-CLEAR WATER RESERVOIR-CUM-PUMP HOUSE OF 250 KL CAPACITY AT ZONE-3WATER WORKS CAMPUS (CWR) 7 RCC CWR;Detailed Survey, Design and Drawing, supply of all material, labour, T&P etc. required for construction of250 KL Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, kota ston floring,bypass arangment ,and soil testing for Bearing capacity of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. Design and Drawing approved by competent authority and Design vetted by Reputed Govt. Engineering College.(250 KL capecity) 8 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofLT Panel Room (RCC Frame Structure) as per type design (5m x 5m x 4 m) 9 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofMeterRoom (RCC Frame Structure) as per type design (4m x 4m x 4 m) 10 Estimate of RCC OverHead Tank of 450 KL. Capacity / 22 M. Staging FOR ZONE -3 Barua Sagar 11 450 KL 22 M Staging Survey Design , drawing and Supply of all materials, labour and T&P etc. complete for the construction of OHT of 450 KL. capacity and staging 22 M with 1.00 m. wide P.C.C. appron all around with 15 cm. Semi circular P.C.C. drain, 1 m. wide RCC stair case from ground level upto balcony, M.S. Ladder with hand rails on both sides from balcony to top dome and inside the tank, 1 m wide RCC balcony alround the tank wall with proper railings of 20 mm. dia. medium quality G.I. pipes in 3 rows on both sides of staircase, balcony and at the top of domes and at each landing supported on RCC posts spaced at not more than 1.50 m. intervals, proper ventilators at top, electronic water level indicator with invertor, Lightening conductor as per latest I.S. code or electricity rules, 600 mm. dia. medium pattern C.I. Manhole cover hinged with locking arrangement, fixing and jointing vertical DID/F pipes, specials and duck foot bends of required size for Inlet, outlet, fixing of outlet sluice valve and washout sluice valves with all jointing materials for proper completion and other appurtenant works, including excavation in all type of soils, painting on exposed surface with one coat of primer and two coats of approved weather coat paint, painting of vertical pipes and railings with approved anticorrosive paints and also including testing of the Overhead Tank, including following items : Supply of following sizes of DID/F pipes conforming to IS 8329 / 2000 or its latest amendment upto rail head including all taxes, duties, insurance etc. Inlet pipe 250 mm. dia.,Outlet pipe 300 mm. dia.,Overflow pipe 300 mm. dia.Washout pipe 100 mm. dia.Carting of above size DI K-9 of pipes upto site of works and lowering them into the trenches and laying true to alignment and gradient and jointing of pipes complete ( including testing of pipelines and cutting of pipes for making up the length excluding the cost of trenches. ) Inlet pipe 350 mm. dia. Outlet pipe 400 mm. dia. Overflow pipe 300 mm. dia. Washout pipe 100 mm. dia . Supply of following diameter ISI Mark Sluice Valve conforming to IS 780/ 1984 or its latest amendment of standard make ( Kirloskar or IVC make ) including all taxes etc. and carting, loading and uploading upto departmental store and carting of following fittings / specials to the site of work, lowering them into the trenches, fixing in position and jointing them with pipe lines, fixing in position and jointing them with pipelines and testing etc. complete including supply of all jointing materials. 400 mm. dia. ( In outlet pipe )100 mm. dia. ( In washout pipe ) Supply of all materials, labours, T&P etc. all complete to construct sluice valve chamber of following sizes.For Outlet Pipe For Washout Pipe Provision for the disposal of overflow water, washout water from chambers to nearest suitable point of disposal including supply of pipes, its laying, jointing, excavation and protection works at the point of disposal. including Provision for soil testing. 12 DISTRIBUTION SYSTEM OF BARUASAGAR ZONE-1,2 and 3 and CLEAR WATERGRAVITY MAIN FROM WTP TO ZONAL WATER WORKS AND RISING MAIN FORZONES-03 (Chui Khadan) BARUASAGAR NAGAR PALIKA PARISHAD 13 Excavation for pipe line trenches in soil mix / all type of rocks with moorum/shingles/kanker requiring use of special T&P ie. pick axe, sabbals etc. lift upto 1.50 m lead upto 50 m. stacking and spreading as directed, normal dewatering,preparing the bed,Filling watering ramming of excavated earth into pipe line trenches and disposal of surplus earth upto a distance of 10 KM from the centre of the pipe line trenches 14 0.00 To 1.5 m Depth 15 Same as above but excavation in all type of rock 16 0.00 To 1.5 m Depth 17 Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) andand Supply of specialsconforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. with jointing Materials including all taxes, freight, loading, unloading, insurance, duties etc., all complete. and supply of all DI DF/DI DS specialslike Tees, all type bend ( For Distribution, Feedermain And Rising main Purpose ) 18 80 mm Dia DI K-7 19 100 mm diaDI K-7 20 125 mm diaDI K-7 21 150 mm diaDI K-7 22 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3DI K-7 23 250 mm diaDI K-7 24 200 mm dia DI-K-9 25 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete.Carting of following sizes (Dia. in mm.) of pipes and specials including jointing mateirals from store to site of work lowering the same into excavated pipe line trenches true to alignment and gradient and jointing the same including testing of pipe line including supply of all materials labour T&P etc complete and as per direction of Engineer Incharge. 26 80 mm Dia 27 100 mm dia 28 125 mm dia 29 150 mm dia 30 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3 31 250 mm dia 32 200 mm dia DI-K9 Zone-3 33 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 34 D.I.Sluice valve 35 100 mm dia 36 150 mm dia 37 200 mm dia 38 250 mm dia 39 Fire Hydrant as per IS Code 908 : 1975 40 65 mm Dia 41 Air valves as per IS 14845 : 2000 PN 1.0 42 50 mm Dia 43 20mm Dia 44 Scour valves 45 50 mm dia 46 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 47 100 mm dia 48 150 mm dia 49 200 mm dia For Zone -3 50 250 mm dia 51 Fire Hydrant as per IS Code 908 : 1975 52 65 mm Dia 53 Air valves as per IS 14845 : 2000 PN 1.0 54 50 mm Dia 55 20 mm Dia 56 Scour valves 57 50 mm dia 58 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 59 Sluice valve chambers (Masonry type) 60 100 mm to 250 mm dia 61 Scour valve chambers (Masonry type) 62 Fire hydrantschambers 63 Air valve chambers 64 Dismantling (cutting by sharp eage machine tools) and Reinstatment of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials. 65 Bituminious Road 66 Cement Concrete Road (CC) 67 Interlocking Tiles Road 68 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main including supply of all labour, material, T&P etc. complete as per the details given below :- 69 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage etc. 70 Provision for crossing of Nalas (0.5mto 2.0 m innerwidth) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 71 0.5 - 1.0 m 72 1.0 - 1.5 m 73 1.5 - 2.0 m 74 Providing new water supply house connection to the consumersfrom new distribution pipe line of following diametersincluding making ferrule connection, cost of ferrule, 15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P Including Dismentling and Reinstatment etc. required for proper completion of the work. As per attached drawing. 75 In all tupe of soil and rock 76 Bituminious Road 77 For 80 to 100 mm dia 78 For 125 to 150 mm dia 79 For 200 mm dia 80 Cement Concrete Road 81 For 80 to 100 mm dia 82 For 125 to 150 mm dia 83 For 200 mm dia 84 Interlocking Tiles Road 85 For 80 to 100 mm dia 86 For 125 to 150 mm dia 87 For 200 mm dia 88 Kachha Road 89 For 80 to 100 mm dia 90 For 125 to 150 mm dia 91 For 200 mm dia 92 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 93 Brick masonry in cement mortar 1:4 94 12mm thick plaster in cement mortar 1:4 95 RCC M-20 (including MS work) 96 Stone masonry in cement mortar 1:6 97 Shifting of Existinghouse connection from existing pipe line to new pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 98 Repairing of house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 99 Barricating of pipe line trenches by using bamboo poles,sheets, rope with red flags, Glow-caution boards, diversion boards & red lights Complete as per the direction of engineer incharge 100 Interconnection of existing pipe line to new pipe line including fitting special pipe, tee, bend, reducer pipe all complete as per site requirment T&P etc material complete as per the direction of engineer incharge 101 80 mm dia 102 100 mm dia 103 125 mm dia 104 150 mm dia 105 Disposal of surplus earth includingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 106 Boundary wallat zone -3 (chhui khadan) Rcc column based boundary wall as per design 30x50 m BOUNDARY WALL Construction of Boundry wall around campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work including supply of all Materials, Labour, Tools and Plants etc. complete., as per departmental type drawing.Construction of2.0 meter high compound wall from formation level of campus,comprising of 230mmx230mm RCC Columns @ 3.0 m c/c distance with 230 mm thick beam at plinth and top, brick work of 230 mm thick in 1:4 and 12 MM THICK 1:4 cement plaster over all surface of wall , two coat of Exterior emulsion paint of approved reputed make over one coat of primer and even surface preparation by applying 2-3 layer of approved reputed make Puttyas perdesign approved by engineer in Charge, including supply of all material, labour, T& P etc complete. 107 3.60 m wide mild steel gate with rcc columns with 1.0 m wicket gate 108 earth filingincludingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 109 Provide all materials, labour and T&P to construct single roomed staff quarter as per type design and quantities of unit estimate all complete , including common stair case and other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm.Detailed Survey, Design& Drawing, Construction of Residential Building based Office Building on R.C.C frame structure at different location finished with all respect, flooring made up with vitrified Tile/ Kota stone , Flush door shutter , glazed window cum ventilation including mosquito proof shutter, waterproofing at roof , anti-skid tile at toilet / bathroom / kitchen , water supply and sanitary work & electrification with all fixture, painting with 3 coat apex at exterior surface and emulsion at interiorsurface including2 coat Birla white puttyofbuilding, apron around building, appropriate size of septic tank and soak pit, including supply of all material, labour, T&P complete as per the direction of the engineer in charge 110 Plinth area of building 57.706 Sqm 111 Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movemen 112 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 113 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 114 Cement Concrete Road(100mm Thick PCC 1:4:8 and 100mm Thick CC 1:2:4) 115 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 30% new + 70% old 116 E and M Work 117 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-1) KHANDI (2.5 MLD) 118 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 119 2050LPM, 25.00 HP, 37m Head 120 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm bend, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 121 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 122 Valve actuator of size 150mm for pumps and common header 123 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 124 150 mm Dia 125 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 126 Electromagnetic flow meter of size 150mm for common header 127 ELECTRICAL ITEMS:- 128 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 129 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 130 CE/UL Certified level transmitter for Intake well :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 131 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 132 CE/UL Certified Pressure transmitter for pumps 133 CE/UL Certified Pressure transmitter forCommon Header 134 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 135 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 136 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 137 Cable trench Chequerred plate 138 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 139 Internal & External electrification of pumping station. 140 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-2)FOR (3.20 MLD+3.50 MLD) 141 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 142 2500LPM, 30.00 HP, 37m Head 143 MAIN PIPING AND VALVES :-Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outsidethe pump house along with 250 x 200 x 250 mm A/F Tee,250 mm bend, 250 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 144 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 145 Valve actuator of size 200mm for pumps 146 Valve actuator of size 250mm for common header 147 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 148 200 mm Dia for pumps 149 250 mm Dia for common header 150 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 151 Electromagnetic flow meter of size 250mm for common header 152 ELECTRICAL ITEMS:- 153 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 154 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 155 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 156 CE/UL Certified Pressure transmitter forpumps 157 CE/UL Certified Pressure transmitter forCommon Header 158 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 159 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 160 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 161 RENNOVATION OF EXISTING 160 KVA SUB STATION AT INTAKEWELL 162 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 163 Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 164 Supplying of 160KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 165 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos.. 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each ACB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 630Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. 166 (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 1Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 167 Supply and laying of 650/1100 volt grade 185 sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x185 sq mm) 168 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 169 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 170 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 171 Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable 172 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 173 NOC from Electrical safety department for all field installations such as pumping plants, substation etc.( 11KV Power connection is already available at site. 174 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT WTP ( EXISTING 125KL/20 M ) 175 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 176 1845 LPM, 25.00 HP, 32m Head 177 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 178 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 179 Valve actuator of size 150mm for pumps 180 Valve actuator of size 150mm for common header 181 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 182 150 mm Dia for pumps 183 150 mm Dia for common header 184 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 185 Electromagnetic flow meter of size 150mm for common header 186 Electromagnetic flow meter of size 250mm at CWR Inlet 187 ELECTRICAL ITEMS:- 188 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 189 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 190 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 191 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 192 CE/UL Certified Pressure transmitter for pumps 193 CE/UL Certified Pressure transmitter forCommon Header. 194 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 195 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 196 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 197 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 198 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 199 Internal & External electrification of CWR 200 PUMPING PLANT AND ACCESSORIES FROM CWR TO CWR HILLOCK ( EXISTING 850 KL) 201 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 202 1845 LPM, 20.00 HP, 22m Head 203 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 300mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 204 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 205 Valve actuator of size 150mm for pumps 206 Valve actuator of size 150mm for common header 207 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 208 150 mm Dia for pumps 209 150 mm Dia for common header 210 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 211 Electromagnetic flow meter of size 150mm for common header 212 Electromagnetic flow meter of size 250mm at CWR Inlet 213 ELECTRICAL ITEMS:- 214 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 215 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION63 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 216 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 217 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 218 CE/UL Certified Pressure transmitter for pumps 219 CE/UL Certified Pressure transmitter forCommon Header. 220 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 221 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 222 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 223 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 224 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 225 Internal & External electrification of CWR 226 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO OHT 350 KL / 22 M 227 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 228 1680LPM, 30.00 HP, 44m Head 229 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 230 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 231 Valve actuator of size 150mm for pumps 232 Valve actuator of size 200mm for common header 233 Valve actuator of size 300mm at OHT Outlet 234 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 235 150 mm Dia for pumps 236 200 mm Dia for common header 237 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 238 Electromagnetic flow meter of size 200mm for common header 239 Electromagnetic flow meter of size 300mm at CWR Inlet 240 Electromagnetic flow meter of size 300mm at OHT Outlet 241 ELECTRICAL ITEMS:- 242 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 243 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 244 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 245 CE/UL Certified level transmitter for CWR 246 CE/UL Certified level transmitter for OHT 247 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 248 CE/UL Certified Pressure transmitter for pumps 249 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 250 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 251 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 252 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 253 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 254 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 255 Internal & External electrification of Pump house 256 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO EXISTING OHT 1100 KL / 17 M 257 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 258 1680LPM, 25.00 HP, 34m Head 259 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 260 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 261 Valve actuator of size 150mm for pumps 262 Valve actuator of size 200mm for common header 263 Valve actuator of size 400mm at OHT Outlet 264 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 265 150 mm Dia for pumps 266 200 mm Dia for common header 267 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 268 Electromagnetic flow meter of size 200mm for common header 269 Electromagnetic flow meter of size 300mm at CWR Inlet 270 Electromagnetic flow meter of size 400mm at OHT Outlet 271 ELECTRICAL ITEMS:- 272 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 273 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION200A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 274 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 275 CE/UL Certified level transmitter for CWR 276 CE/UL Certified level transmitter for OHT 277 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 278 CE/UL Certified Pressure transmitter for pumps 279 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 280 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 281 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 283 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 284 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 285 Internal & External electrification of Pump house 286 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT CHUIKHADAN ( 450KL / 22M ) 287 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 288 1860LPM, 30 HP, 40m Head 289 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 290 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 291 Valve actuator of size 150mm for pumps 292 Valve actuator of size 150mm for common header 293 Valve actuator of size 300mm at OHT outlet 294 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 295 150 mm Dia for pumps 296 150 mm Dia for common header 297 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 298 Electromagnetic flow meter of size 150mm for common header 299 Electromagnetic flow meter of size 300mm at CWR Inlet 300 Electromagnetic flow meter of size 300mm at OHT outlet 301 ELECTRICAL ITEMS:- 302 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 303 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 304 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 305 CE/UL Certified level transmitter for CWR 306 CE/UL Certified level transmitter for OHT 307 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 CE/UL Certified Pressure transmitter for pumps 309 CE/UL Certified Pressure transmitter forCommon Header. 310 CE/UL Certified Pressure transmitter for OHT outlet 311 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 312 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 313 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 314 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 315 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 316 Internal & External electrification of CWR 317 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT KANSHIRAM COLONY (EXISTING) 318 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 319 700LPM, 12.5 HP, 35m Head 320 MAIN PIPING AND VALVES :-Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side and 100mm common Header upto 1 m. outsidethe pump house along with 100 x 100 x 100 mm A/F Tee,100 mm bend, Enlargers, 100 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 321 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 322 Valve actuator of size 100mm for pumps 323 Valve actuator of size 100mm for common header 324 Valve actuator of size 250mm at OHT outlet 325 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 326 100 mm Dia for pumps 327 100 mm Dia for common header 328 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 329 Electromagnetic flow meter of size 100mm for common header 330 Electromagnetic flow meter of size 250mm at CWR Inlet 331 Electromagnetic flow meter of size 250mm at OHT outlet 332 ELECTRICAL ITEMS:- 333 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 334 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION40 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 335 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 336 CE/UL Certified level transmitter for CWR 337 CE/UL Certified level transmitter for OHT 338 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 339 CE/UL Certified Pressure transmitter for pumps 340 CE/UL Certified Pressure transmitter forCommon Header. 341 CE/UL Certified Pressure transmitter for OHT outlet 342 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 343 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 344 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 345 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 346 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 347 Internal & External electrification of CWR 348 INTERNAL AND EXTERNAL ELECTRIFICATION FOR WTP 349 Internal and External Electrification 350 Outdoor Lighting 351 Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. 352 12.5 Mtr. HM (in 2 Section) 353 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. 354 High Power LED Flood Light 200W 355 Indoor Lighting 356 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with2.5 KV internal/external surge protection B|S certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt ,THD < 10 % , p.f.>0.95,CRI >80 . life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000°K / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing and also provide test certificate of LED Fixtures from NABL. 357 36 W LED light Fixture 2 x 2 with acrylic / prismatic front cover. 358 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 359 Automation For Intake Well 360 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 361 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 362 CE/UL Certified Intelligent energy meters 363 CE/UL Certified Surge protector for control panel 364 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 365 Cable 366 (i) Complete cabling above 3 Pumps 367 Security Survelliance IP Camera with recorder (optional) 368 Installation, commissioning & testing 369 AUTOMATION FOR CWR-1A 370 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 371 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 372 CE/UL Certified Intelligent energy meters 373 CE/UL Certified Surge protector for control panel 374 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 375 Turbidity Analyzer at CWR 376 PH Analyzer 377 Chlorine Analyzer 378 Cable 379 (i) Complete cabling upto 3 Pumps 380 Security Survelliance IP Camera with recorder (optional) 381 Installation, commissioning & testing 382 AUTOMATION FOR CWR-1B 383 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 384 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 385 CE/UL Certified Intelligent energy meters 386 CE/UL Certified Surge protector for control panel 387 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 388 Turbidity Analyzer at CWR 389 PH Analyzer 390 Chlorine Analyzer 391 Cable 392 (i) Complete cabling upto 3 Pumps 393 Security Survelliance IP Camera with recorder (optional) 394 Installation, commissioning & testing 395 AUTOMATION FOR CWR-2A 396 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 397 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 398 CE/UL Certified Intelligent energy meters 399 CE/UL Certified Surge protector for control panel 400 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 401 Turbidity Analyzer at CWR 402 PH Analyzer 403 Chlorine Analyzer 404 Cable 405 (i) Complete cabling upto 3 Pumps 406 Security Survelliance IP Camera with recorder (optional) 407 Installation, commissioning & testing 408 AUTOMATION FOR CWR-2B 409 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 410 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 411 CE/UL Certified Intelligent energy meters 412 CE/UL Certified Surge protector for control panel 413 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 414 Turbidity Analyzer at CWR 415 PH Analyzer 416 Chlorine Analyzer 417 Cable 418 (i) Complete cabling upto 3 Pumps 419 Security Survelliance IP Camera with recorder (optional) 420 Installation, commissioning & testing 421 AUTOMATION FOR CWR-2C 422 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 423 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 424 CE/UL Certified Intelligent energy meters 425 CE/UL Certified Surge protector for control panel 426 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 427 Turbidity Analyzer at CWR 428 PH Analyzer 429 Chlorine Analyzer 430 Cable 431 (i) Complete cabling upto 3 Pumps 432 Security Survelliance IP Camera with recorder (optional) 433 Installation, commissioning & testing 434 AUTOMATION FOR CWR-2D 435 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 436 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 437 CE/UL Certified Intelligent energy meters 438 CE/UL Certified Surge protector for control panel 439 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 440 Turbidity Analyzer at CWR 441 PH Analyzer 442 Chlorine Analyzer 443 Cable 444 (i) Complete cabling upto 3 Pumps 445 Security Survelliance IP Camera with recorder (optional) 446 Installation, commissioning & testing 447 Local Control Station at WTP 448 CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification 449 Desktop / PC with i5/i7 processor for as per technical bid documents 450 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 451 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 452 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouseras per spec. mentioned in technical bid documents. 453 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 454 CE/UL Certified firewall for network protection 455 SURGE PROTECTOR FOR ETHERNET communication protection. 456 CE/UL certified industrial grade Ethernet Swtich 457 Cannon/HP or equivalent Laser printer 1018 or equivalent 458 Security Survillance IP Camera with recorder (Optional) 459 Installation, Commissioning & testing including required furniture, A/C etc. 460 Trial & Run 461 03 Months trial & run
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
29.
Drinking Water Supply and Sanitation #9443546 Technical Bid
tender for Operation And Maintenance Of Jhansi Augmentation Water Supply Scheme 110 Mld And Jhansi Babina Water Supply Scheme 45 Mld Operation And Maintenance Of Jhansi Augmentation Water Supply Scheme 110 Mld And Jhansi Babina Water Supply Scheme 45 Mld For 1 Year The Scope Includes Oandm Of Intake Works Raw Water Mains Wtp Clear Water Mains And Other Ancillary Components, 1 Part-A (Civil work) 2 Skilled Operating Staff for Operation and Watch & Ward of 45 mld and 110 mld WTP 3 Providing of skilled operating stafffor opening and controllingsluice valve at CP tank (Head work Matateela ) in three shift at 45 MLD02 in each shift 4 1st shift(02 nos in each shift@ Rs 420 each) 5 2 nd shift(02 nos in each shift@ Rs 420 each) 6 3rd shift(02 nos in each shift@ Rs 420 each) 7 Providing of Skilled Petroling staff for Raw Water GravityMain pipe lineMatateela head work toBabina wtp - 20.0 km approx (1x3= 3 for 365 days @ Rs 420 each for 8 hours foreach shift) 8 Clear Water GravityMainBabina to Elite CircleJhansi 27.50 km approx(1x3= 4 for 365 days @ Rs 420 each for 8 hours foreach shift) 9 Providing of skilled operating stafffor Back wash operatingsluice valve,air sluice valve,in three shift at WTP 45 MLD plant(2 Nosin each shift x 3= 6 nos for 365 days=2190 nos) 8 hours foreach shift 10 Providing of skilled operating stafffor Back wash operatingsluice valve,air sluice valve,in three shift at WTP 110 MLD plant (2 Nosin each shift x 3= 6 nos for 365 days=2190 nos) 8 hours foreach shift 11 Providing of Skill stafffor maintinance of Chlorinator plant and PAC Doasing Machine works at 45 mldWater Tretment Plant (1 Nosin each shift x 3= 3 nos for 365 days=1095 nos) 8 hours foreach shift 12 Providing of Skill stafffor maintinance of Chlorinator plant and PAC Doasing Machine works at 110 mldWater Tretment Plant (1 Nosin each shift x 3= 3 nos for 365 days=1095 nos) 8 hours for each shift 13 CleaningofAlgae&othersuspendedmaterialfromInletChannelscreem , CLF , filter bed , settle water channelbymanuallabourandDisposalofAlgae &other suspended material from Inlet Channel to suitable place With in 8 km for 45 mld .(2x365 days=730 ) 8 hours foreach shift 14 CleaningofAlgae&othersuspendedmaterialfromInletChannelscreem , CLF , filter bed , settle water channelbymanuallabourandDisposalofAlgae &other suspended material from Inlet Channel to suitable place With in 8 km for 110 mld ..(2x365 days=730 ) 8 hours foreach shift 15 Horticulture works at Head Work (Matateela) and water treatment plant Campus Babina and other related works for45 mld and 110 mld WTP 16 Maintenance of the entire garden features in the garden area i.e. feeding of water,lawn trees, shrubs, hedge, flower beds, creepers etc. including hoeing, pruning replacement of plants gap filling, watering, mowing of lawn, clipping of hedge, removal of garden waste, applyinginsecticide,pescticide,fertilizer&Manures per month including all T&P as per the direction of ingineer incharge 17 Operation & Maintenance of Laboratory 18 Providing Lab Technicion/chemist (MSC Qualified) for Water test and maintain quality of dinking water as per CPHEO GUDE of turbidity, PH Value of water, Dosing of PAC, Jar test, Chlorine (Pre and Post) etc. at 45 MLD. WTP and 110MLD. WTP at BABINA . (1x 365 Days = 365 days) 19 Providing of labour for collection of water sample from bulk consumer located at different location weekly (2 nos x 4nos x12months = 96 days 20 Providing of labour for water meater reading and distribution of water bills for bulk consumer located at different location weekly (4 nox12 = 48 days) 21 Providing of labour for water meater readinglocated at Bijoli(2 no x365 days = 730 Nos) 22 Supply and installation of Laboratorary Equipment as per latest modle and specification including transportation,fright charges, loading and unloading complete asthe direction of engineer incharge complete . 23 Hot air oven 60 Lt (Make - Lefco India, Thermo Fisher) 24 Auto Clave 50 L(Make - Lefco India, Thermo Fisher) 25 Incubator 112 L (Make - Lefco India, Thermo Fisher) 26 Jar floculator (Make - Lefco India, Thermo Fisher) 27 Digital Balance Up to fourth decimal place(Make-Dhona,) 28 Digital Burette (Thermo Fisher) 29 Fluoride Ion Meter (Make -Thermo Fisher) 30 Ph meter(Make -Thermo Fisher) 31 Conductivity Meter(Make -Thermo Fisher) 32 Turbidity meter(Make -Hach) 33 Double Distillation Apparatus (Make -Borosil) 34 Filtration Assembly with Vacume pump (Make -Borosil) 35 UV Double Beam Spectrophotometer LI126 (Make Elico,Thermo Fisher) 36 UV Leminar air flow (Make - Lefco India, Thermo Fisher) 37 Water Bath 12 holes 38 Bunsen Electric Hot palte 10x12 inch ractangular 39 Refrigerator (LG 408 Lt frost free double door 3 star convertible Modle No- GLT412VESX) 40 Flume Hud (Make - Lefco India, Thermo Fisher) 41 Glasswares 42 Flask flat Bottom -1000ml Borosil with NABL 43 Flask Conical -250ml,Borosil with NABL 44 Flask Conical -100ml Borosilwith NABL 45 Flask Volumetric -1000ml BorosilClass A with NABL 46 Flask Volumetric -500ml BorosilClass A with NABL 47 Flask Volumetric-250ml BorosilClass A with NABL 48 Flask Volumetric -100ml BorosilClass A with NABL 49 Flask Volumetric - 50ml Borosil Class A with NABL 50 Pipettes Volumetric -50ml BorosilClass A with NABL 51 Pipettes Volumetric-25 ml BorosilClass A with NABL 52 Pipettes Volumetric -20 ml Borosil Class A with NABL 53 Pipettes Volumetric- 10 ml Borosil Class A with NABL 54 Pipettes Volumetric -5 ml BorosilClass A with NABL 55 Pipettes Graduated-25 ml BorosilClass A with NABL 56 Pipettes Graduated -10 ml BorosilClass A with NABL 57 Pipettes Graduated -5ml BorosilClass A with NABL 58 Measuring Cylinder -250ml Borosil Class A with NABL 59 Measuring Cylinder -100ml BorosilClass A with NABL 60 Measuring Cylinder -50ml BorosilClass A with NABL 61 Burette- 50ml BorosilClass A with NABL 62 Burette-25ml Borosil Class A with NABL 63 Reagent Bottle -2000ml Borosilwith NABL 64 Reagent Bottle -1000ml Borosilwith NABL 65 Reagent Bottle -500ml Borosilwith NABL 66 Reagent Bottle -250ml Borosilwith NABL 67 Reagent Bottle -125ml Borosilwith NABL 68 Test Tube Size -150x18mm Borosilwith NABL 69 Test Tube Size- 125x15mm Borosil with NABL 70 Funnel Size -7.5 cm Borosil with NABL 71 Beaker -1000ml Borosilwith NABL 72 Beaker -500ml Borosilwith NABL 73 Beaker -250ml Borosilwith NABL 74 Beaker -100ml Borosilwith NABL 75 Porcelin Basin white with NABL 76 Nesseler Cylinder -100ml Borosil with NABL 77 Nesseler Cylinder -50ml Borosil with NABL 78 Petridish Size- 100mm Borosilwith NABL 79 Fermantation Tube Borosilwith NABL 80 Watch glass Borosilwith NABL 81 Burette stand Poly lab with NABL 82 Desiccator -150 mm Borosylicate with NABL 83 Chemicals 84 Silver Nitrate AR (Merck)-25 gram 85 Potassium Chromate AR (Merck)-500 gram 86 EDTA disodium AR (Merck)-100 gram 87 Eriochrome Black T AR (Merck)-25 gram 88 Magnesium Sulphate AR(Merck)-500 gram 89 Ammonium Hydroxide 25% AR (Merck)-2.5 lit 90 Murexide (Ammonium Purpurate) AR (Merck)-5 gram 91 Ethylene Glycol (Absolute) AR (Merck)-500 gram 92 Sodium Chloride AR (Merck)-500 gram 93 Phenolpthalein Indicator AR (Merck)-125 ml 94 Methyl Orange AR (Merck)-25 gram 95 CDTA AR (CDH) -100 gram 96 Hydrochloric Acid AR (Merck)-2.5 lit 97 Sulfuric Acid 98% AR (Merck)-2.5 lit 98 Acetic Acid glacial AR (Merck)-2.5 lit 99 Ammonium AcetateAR (Merck)-500 gram 100 Hydroxylamine Hydrochloride AR (Merck)-250 gram 101 1-10 Phenanthroline AR (Merck)-5 gram 102 Ethyl Alcohal AR (Merck)-500 ml 103 Barium Chloride AR (Merck)-500 gram 104 Glycerol AR (Merck)-500 ml-500 gram 105 Potassium Permanganate AR (Merck) 106 Sodium Hydroxide AR (Merck)-500 gram 107 Beef Extract (Merck)-500 gram 108 Lactose (Merck)-500 gram 109 Agar - Agar (Bact.) (Renkam)-500 gram 110 Sodium Chloride (Merck)-500 gram 111 Peptone Bacteriological(Renkam)-500 gram 112 Sodium Tourocholate (Loba)-500 gram 113 Nuteral Red Indicator (Fisher)-25 gram 114 Sodium Hydroxide (Merck)-500 gram 115 Magnese Sulfate (Merck)-500gram 116 Extran (Merck) MA01-500ml 117 Ortho - Tolidine Solution (Qualigen)-500 ml 118 Sodium Azide (Merck)-100gram 119 Strach-500 gram 120 Providing on Sweeper for cleaning of road, drains, quarters and other units at Water treatment plant Campus at babina (3 Nos x 365 Daysat WTP Campus) 121 Providing on Sweeper for cleaning of road, drains, quarters and other units atmatateela Campus head water works (1 No x 365 Days= 365days) 122 Providing ofhelper for cwr Jhansi for watch and ward of bulk consumer maintinace purpose in three shift(5nos x 365 days = 1825 Nos) 123 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 124 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 125 Cement Concrete Road 126 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 100% new 127 Filter Media for 110 mld & 45 mld 128 Supply & fixing as per specification provided by department of Filter media for Filter beds effective size of 0.45mm to 0.70 mm of 80 CM height over graded gravel as per drawingattatched on tender document. 129 Supply of supporting media gravel of size 3 mm to 6 mm of 20 cm heightas per drawingattatched on tender document. 130 Removal of old filtration media sand and supporting media gravel from the filter bed and filling the new filtration media sand and supporting media gravel as per direction of site incharge including supply of labour material and T&P etc complete 131 (Chemical for 45 mld and 110 mld WTP ) 132 Supply of Bleaching powerat site of 110 MLD and 45 MLD W.T.P Babina including carting , loading , unloading etc. complete. 133 Lumpsump provision for repairing of leakage at different locationin differentdia of Raw water and Clear Water gravity main pipelinein the water supply system located fron matateela to jhansi (including Carting of material from central store such hiring of pump set, deisel, jointing material, cememt sand,Lead wool, cico no -2 etc which is required at site)For 45 mld and 110 mld WTP 134 For 110 mld WTP - 1400 mm dia PSCpipe in Gravity main ( Running pipe line )Matateela to Babina - 20.0 km approx 135 For 110 mld WTP - 1300 mmdia PSCpipe in Gravity main ( Running pipe line ) Babina to Hansri 22.50 km approx 136 For 110mld WTP - 1200 mm dia PSCpipe in Gravity main ( Running pipe line ) Hansri to Jal nigam Colony Jhansi5.0 km approx 137 For 45 mld WTP - 42 dia PSCpipe in Gravity main ( Running pipe line ) Matateela to Babina - 20.0 km approx 138 For 45 mld WTP - 33 dia PSCpipe in Gravity main ( Running pipe line ) Babina to MES Jhansi 24.0 km approx 139 For 45 mld WTP - 21 dia PSCpipe in Gravity main ( Running pipe line ) Babina to MES Jhansi 1000 m approx 140 For 110 mld WTP - 250 dia ACpipe in Gravity main ( Running pipe line )sale tax road to Medical college Jhansi 7 km approx 141 For 110 mld WTP - 200 dia DIpipe in Gravity main ( Running pipe line ) CWR to IGFRI Campus Jhansi 9.0 km approx 142 For 110 mld WTP - 150&125 mm dia DIpipe in Gravity main ( Running pipe line ) CWR to Army aviation Jhansi 5.0 km approx 143 Part B (E & M works) 144 E&M Operation and Maintenance Staff at Head Works Matatila 145 Providing of Skilled eletrician for maintinance of electrical equipments and other related eletrical works atMatatila head works01 in each shift 8 hours 146 1st shift 147 2 nd shift 148 3rd shift 149 Providing of Skilled mechanic for maintinance of mechanical equipments and other related eletrical works atMatatila head works01 in each shift 8 hours 150 1st shift 151 2 nd shift 152 3rd shift 153 Providing of Skilled operator for operation ofpumps , DG set and associated mechanical & electrical equipmentsatMatatila head works01 in each shift 8 hours 154 1st shift 155 2 nd shift 156 3rd shift 157 Providing of Skilled helper for electrician and mechanicatMatatila head works01 in each shift 8 hours 158 1st shift 159 2 nd shift 160 3rd shift 161 Routine, periodically and breakdown maintinance of all equipments, associated accessories installed at verious units at Matatila head works including supply,opening and refixing,fright charges, transportation , loading unloadingall T&P etc. complete as per the direction of engineer incharge. 162 Matatila Head works 163 Routine maintinance and servicing of 320 KVA D G set including all necessary spares, oil, Filters, Diode and lubricant as per norms 164 Repairing and Overhauling of 650 LPS discharge kirlosker make pumps with following works. Model MF 40-45 165 Dismantling, carting and re-installation of pump set including testing on load at site with all labour and T&P 166 Supply and fixing of new ball bearing-6415 and oil seal. 167 Supply and fixing of new thrust bearing-51320M 168 Fabrication, Supply and fixing of fully balanced new pump shaft made of SS 410 as per sample. 169 Reconditioning of pump shaft with rematling, machining and balancing complete in all respect. 170 Reconditioning of pump impeller with rematling, machining and balancing complete in all respect. 171 supply and fixing of New impeller for pump as per sample and zise 172 Supply and fixing of new shaft sleeve, chuck nut made of SS 410 as per sample. 173 Supply and filling of lubricating oil in every 6 months 174 Supply and fixing of new Fastners 175 Supply and filling of Glande packing as per size and sample. 176 Supply and fixing of new Glande plate with stud and nut. 177 Repairing & maintenance of kirloskar make induction motor with following works 178 Dismantling, carting and re-installation of motor including testing on load at site with all labour and T&P 179 Rewinding of 75 KW, 736 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 180 Rewinding of 55 KW, 736 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 181 Supply and fixing of new ball bearing-NU318C3 182 Supply and fixing of new ball bearing-6318C3 183 Fabrication, Supply and fixing of new rotar shaft as per sample and material. 184 Reconditioning of rotar shaft with rematling, machining and balancing complete in all respect. 185 Reconditioning of bearing housing with rematling, machining and balancing complete in all respect. 186 Routine Greasing of induction motor bearings with high temprature Jelly grease in every 30 days intervals 187 Supply and fixing of new Fastners 188 Supply and fitting of motor connection plate with suitable size of lugs as per sample etc. complete. 189 Repairing and Maintenance of 600mm size sluice valve with following works 190 Dismantling, carting and re-installation of sluice valve with all labour and T&P 191 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 192 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 193 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 194 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 195 Supply and filling of Glande packing as per size and sample 196 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 197 Repairing and rewinding of exhaust fan size 600mm with replacing of barings etc. complete. 198 Complete wiring of H.T panel room with 1.5 and 2.5 Sq.mm multi strands copper conductor wire PVC insulated including Caping casing,power board, 5 Amp. switch and socket as per direction of engineer incharge with all labour, T&P and materials 199 Supply and fixing of dial gauge type pressure guage with cock at outlet of pump set 200 Servicing and overhauling of HOT crane including replacement of warmout parts with all labour and T&P 201 Routine Servicing of HT Panel 202 supply & fixing of Lov joy coupling for pumpset model C-2955 203 supply and fixing of power & control card for 110 KW Soft starter as per sample 204 Maintinance of all campus lighting, Head work Matatila andother building etc. includingsupply, fixing fright charges all T&P all complete as per the direction of engineer incharge (Brand name Syska, Philips,Bajaj,Havells) 205 LED Bulb 206 Supply and Fixing of 9 Watt 207 Supply and Fixing of 20 Watt 208 Supply and Fixing of 30 Watt 209 Supply and Fixing of 40 Watt 210 Supply and Fixing of 50 Watt 211 LED Tube light 212 Supply and Fixing of 22 Watt 213 Supply and Fixing of 36 Watt 214 LED StreetFlood light 215 Supply and Fixing of 50 Watt 216 Supply and Fixing of 100 Watt 217 Supply and Fixing of 1200mm size 218 E&M Operation and Maintenance Staff at 110 MLD & 45 MLD WTP Babina 219 Providing of Skilled eletrician for maintinance of electrical equipments and other related eletrical works at110 MLD & 45 MLD WTP Babina01 in each shift 8 hours 220 1st shift 221 2 nd shift 222 3rd shift 223 Providing of Skilled mechanic for maintinance of mechanical equipments and other related eletrical works at110 MLD & 45 MLD WTP Babina 01 in each shift 8 hours 224 1st shift 225 2 nd shift 226 3rd shift 227 Providing of Skilled operator for operation ofpumps , DG set and associated mechanical & electrical equipmentsat 110 MLD & 45 MLD WTP Babina01 in each shift 8 hours 228 1st shift 229 2 nd shift 230 3rd shift 231 Providing of Skilled helper for electrician and mechanic110 MLD & 45 MLD WTP Babina02 in 1st shift and 01 in other shifts 8 hours 232 1st shift (02Nos@Rs 350/- = Rs 700/-) 233 2 nd shift 234 3rd shift 235 Routine, periodically and breakdown maintinance of all equipments, associated accessories installed at verious units of 45 mld 110 mld WTP including supply,opening and refixing,fright charges, transportation , loading unloadingall T&P etc. complete as per the direction of engineer incharge. 236 110 MLD & 45 MLD WTP Babina 237 Rewinding and repairing of flash mixture induction motor having capacity of 5 hp, 3 phase with replacement of bearingsincluding Loading-unloading, Transportation etc. complete with testing on load 238 Repairing and overhauling of Grear box of flash mixture including replacement of warmout parts, bearings, Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 239 Repairing and Overhauling of Sluice Gate 1100x1300 mm size at flash mixer with following works 240 Dismentaling, carting, refitting and testing with all labour and T&P required at site 241 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 242 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 243 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 244 Repairing and Overhauling of Sluice gate 1300x1500 mm size with following works :- 245 Dismentaling, carting, refitting and testing with all labour and T&P required at site 246 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 247 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 248 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 249 Filter Bed No-8 @13.75 mld each 250 Repairing and Overhauling of Sluice Gate 450x450 mm size at Filter Bed Inlet with following works :- 251 Dismentaling, carting, refitting and testing with all labour and T&P required at site 252 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 253 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 254 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 255 Repairing and Overhauling of Sluice Gate 600x450 mm size at Backwash Outlet with following works :- 256 Dismentaling, carting, refitting and testing with all labour and T&P required at site 257 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 258 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 259 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 260 Repairing and Overhauling of 500mm dia size sluice valve at Backwash water inlet with following works. 261 Dismantling, carting and re-installation of sluice valve with all labour and T&P 262 Supply and fixing of spendle for sluice valve made of SS 316 as per size and sample 263 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 264 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 265 Supply and fixing of Glande plate with Studs as per sample 266 Supply and filling of Glande packing as per size and sample 267 Repairing and Maintenance of 200mm dia size Sluice valve at Backwash Air Inlet with following works :- 268 Dismantling, carting and re-installation of sluice valve with all labour and T&P 269 Supply and fixing of spendle for sluice valve made of SS 316 as per size and sample 270 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 271 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 272 Supply and fixing of Glande plate with Studs as per sample 273 Supply and filling of Glande packing as per size and sample 274 Repairing and Maintenance of 300mm dia size Sluice valve at Filter Water Outlet with following works :- 275 Dismantling, carting and re-installation of sluice valve with all labour and T&P 276 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 277 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 278 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 279 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 280 Supply and filling of Glande packing as per size and sample 281 Repairing and Maintenance of 100mm dia size Sluice valve for Chamber cleaning with following works :- 282 Dismantling, carting and re-installation of sluice valve with all labour and T&P 283 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 284 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 285 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 286 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 287 Supply and filling of Glande packing as per size and sample 288 Clarifloculator -1&2 289 Rewinding and repairing of 5 hp motor 3 phaseInduction motor including replacement of bearings, Dismentaling, Transportation, Refitting with testing on load 290 Repairing and Overhaulig of Gear box coupled with 5 H.P. Induction motor including replacement of warmout parts, Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 291 Repairing of Desludging Valve 300 mm dia Weidge Piece brass & Gun metal 292 Repairing of Desludging Valve 300 mm dia Spendle brass & Gun metal 293 Tefloan CLF wheel 294 Repairing and Overhauling of Swam make Air Blower with following works :- 295 Dismantling, carting and re-installation of Air blower with all labour and T&P 296 Repairing and Overhualing of 2500 cum/hrs capacity Air Blower including replacement of bearings, damaged parts complete with testing on load 297 Rewinding and repairing of 60 hp, 3 Phase induction motor of air blower including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 298 Replacement of bearing no. 6313 299 Repairing and Overhauling of 483.33 LPS discharge kirlosker make backwash pumps with following works. Model No. 35-40 300 Dismantling, carting and re-installation of pump set including testing on load at site with all labour and T&P 301 Supply and fixing of new ball bearing-6412 and oil seal. 302 Supply and fixing of new thrust bearing-51314M 303 Fabrication, Supply and fixing of fully balanced new pump shaft made of SS 410 as per sample. 304 Reconditioning of pump shaft with rematling, machining and balancing complete in all respect. 305 Reconditioning of pump impeller with rematling, machining and balancing complete in all respect. 306 Supply and fixing of new shaft sleeve, chuck nut made of SS 410 as per sample. 307 Supply and filling of lubricating oil in every 6 months 308 Supply and fixing of new Fastners 309 Supply and filling of Glande packing as per size and sample. 310 Supply and fixing of new Glande plate with stud and nut. 311 Repairing & maintenance of kirloskar make induction motor of 150 HPfor Backwash pump with following works 312 Dismantling, carting and re-installation of motor including testing on load at site with all labour and T&P 313 Rewinding of 110 KW / 150 HP, 980 rpm, 3 Phase induction motor with F-class insulated copper wire, nomax paper, sleeves, varnishing etc. complete with all material and T&P. 314 Supply and fixing of new ball bearing-NU319C3 315 Supply and fixing of new ball bearing-6319C3 316 Fabrication, Supply and fixing of new rotar shaft as per sample and material. 317 Reconditioning of rotar shaft with rematling, machining and balancing complete in all respect. 318 Reconditioning of bearing housing with rematling, machining and balancing complete in all respect. 319 Routine Greasing of induction motor bearings with high temprature Jelly grease in every 30 days intervals 320 Supply and fixing of new Fastners 321 Supply and fitting of motor connection plate with suitable size of lugs as per sample etc. complete. 322 Chlorine OHT feeded pump 323 Rewinding and repairing of 5 hp 3 Phase motor with F class insulated copper wire, nomax paper, glass lead etc. including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 324 Repairing and Overhauling of 4.17 LPS, 18 mtr. head, 2900 RPM end suction horizontal centrifugal pump with replacement of bearings, reconditioning of pump shaft, bearing housing etc. complete including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 325 Supply,, Installation,, Testing and commissioning of PAC Doasing pump 326 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 327 45 mld WTP 328 Flash Mixture 329 Rewinding and repairing of flash mixture 7.5 hp mortor 3 phaseincluding Loading Transportation etc. complete with testing on load 330 Repairing and Overhauling of flash mixture Grear box with replacement of warmout parts including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 331 Clarifloculator -1&2 332 Rewinding and repairing of gear fan motor 5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 333 Repairing of Gear box of gear fan motor including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 334 Rewinding and repairing of main drive 5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 335 Repairing of Gear box of main drive including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 336 Repairing of Desludging Valve 300 mm dia Weidge Piece brass & Gun metal 337 Repairing of Desludging Valve 300 mm dia Spendle brass & Gun metal 338 Tefloan CLF wheel 339 Filter Bed No-5 @ 9.0 mld each 340 Repairing and Overhauling of Sluice Gate 500x500 mm size at Backwash Outlet with following works :- 341 Dismentaling, carting, refitting and testing with all labour and T&P required at site 342 Fabrication, Supply and fixing of new threaded spindle shaft made of SS:316 as per size and sample 343 Fabrication, Supply and fixing of new bush made of Gun metal and wage piece as per size and sample 344 Fabrication, Supply and fixing of new fix and moving sheet made of Gun metal as per size and sample 345 Repairing and Overhauling of 500mm dia size sluice valve at Backwash water inlet with following works. 346 Dismantling, carting and re-installation of sluice valve with all labour and T&P 347 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 348 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 349 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 350 Supply and fixing of Glande plate with Studs as per sample 351 Supply and filling of Glande packing as per size and sample 352 Repairing and Maintenance of 300mm dia size Sluice valve at Filter Water Outlet with following works :- 353 Dismantling, carting and re-installation of sluice valve with all labour and T&P 354 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 355 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 356 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 357 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 358 Supply and filling of Glande packing as per size and sample 359 Repairing and Maintenance of 300mm dia size Sluice valve for Raw Water Inlet with following works :- 360 Dismantling, carting and re-installation of sluice valve with all labour and T&P 361 Supply and fixing of spendle for sluice valve made of SS 304 as per size and sample 362 Supply and fixing of Bush for sluice valve made of gun metal as per size and sample 363 Supply and fixing of Disc and body sheet for sluice valve made of gun metal complete with all maching and finishing 364 Supply and fixing of Glande plate with Studs 600mm size sluice valve as per sample 365 Supply and filling of Glande packing as per size and sample 366 Back Wash Pump motor 367 Rewinding and repairing of Back wash motor 15 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 368 Repairing of Backwash pump of 15 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 369 Rewinding and repairing of Back wash motor 12.5 hp motor 3 phaseincluding Loading Transportation etc. complete with testing on load 370 Repairing of Backwash pump of 12.5 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 371 Repairing and rewinding of exhaust fan size 450mm with replacing of barings etc. complete. 372 Repairing and rewinding of Ceiling fan with replacing of barings etc. complete. 373 ForGardening, Colony and Block Supply 374 Rewinding and repairing of 7.5 hp 3 Phase motor including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 375 Repairing of Backwash pump of 7.5 hp including Dismentaling, Loading, Carting and reinstallation etc. complete with testing on load 376 supply and fixing of power & control card for 110 KW Soft starter as per sample 377 supply and fixing of power & control card for 45 KW Soft starter as per sample 378 Repairing and overhauling ofgarvity feed type Chlorination system complete at 110 & 45 MLD WTP Babinacapacity complete with all required spare parts 379 Supply and fixing of variable friquency drive (VFD) panel with all protective devices suitable to operate 150 HP backwash pumping plant as per relevant IS code 380 Maintinance of all campus lighting, 45 mld 110 mld WTP Babina and laboratory house and other building etc. includingsupply, fixing fright charges all T&P all complete as per the direction of engineer incharge (Brand name Syrya, Syska, Philips,Bajaj,Havells) 381 LED Bulb 382 Supply and Fixing of 9 Watt 383 Supply and Fixing of 20 Watt 384 Supply and Fixing of 30 Watt 385 Supply and Fixing of 40 Watt 386 Supply and Fixing of 50 Watt 387 LED Tube light 388 Supply and Fixing of 22 Watt 389 Supply and Fixing of 36 Watt 390 LED StreetFlood light 391 Supply and Fixing of 50 Watt 392 Supply and Fixing of 100 Watt 393 Supply and Fixing of 1200mm size
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
30.
Defence #9416178 AOC
Tender For Provision Of Oh Tanks Ug Sumps And External Services For Map Ph-Ii Under Ge S Pune And Ge N Pune.; 1 SCH A PART-I TO VII:Note: These schedules are pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structure) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch A Part-IV (Sewage Disposal) 6 Total amount of Sch A Part-V (External Water Supply) 7 Total amount of Sch A Part-VI (External Electric Supply) 8 Total amount of Sch A Part-VII ( LIGHTNING PROTECTION ) 9 Total amount of Sch A Part-VIII (Excavation and Earthwork) 10 SCHEDULE A PART-IX (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only. 11 MISC ITEMS E/M WORKS OF INTERNAL & EXTERNALELECTRICAL SUPPLY 12 S&FLEDstreet light luminaire 25 W with pressure die castaluminium housing LED street light luminaries with IP66 with 25 W high power LED, maintenance free system and connecting up with cable, including 1.5 m long GI bracket of required dia, bent to shape, clamp and nut bolts of suitabler size complete all as specified and all as directed. 13 S&F solar powered aviation obstructionlamp complete sysytem make: Altos model AOL-Q-3 SP or equivalent model in philips / Crompton Greaves / bajaj consisting of : (a)LED based avitation obstruction lamp fitting (b) solar panel (c)Battery unit (d) Mounting structure for all above with inter connecting wiring complete all as specified and ditected. 14 Testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 100 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV, 3 PH, LT-433 Vand making compete connection of HT and LT Sidewith glands, lugs complete all as specified and directed.(Note- Transformer already installed /mounted on platform at site , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item. 15 All as per item No- 11.003above but capacity22 KV 200 KVA. 16 Installation, testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 300 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV,LT-433 V and making connection on HT & LT side with gland and lugs , The transformer will mount on platform as per manufacturer instruction 0r Typical drawing or of size of size 2.00 M x 2.00 M x 3.50 M deep (1.00 m below GL) withPCC (1:3:6) type C2 and15 cm thick RCC (1:2:4) type B1 for top, reinforced with 10 mm dia TMT bars @ 150 mm C/C complete including excavation & earthwork in any type of strata viz soft/loose/hard/dense/Rock, frame work all as specified and directed(Note- Transformer shall be issued under Sch B free for fixing , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item.The rate quoted by the contractor shall deemed to be included the cost offoundationa and transportation of transformer from MES yard to work site.No extra payment shall be made on this account.) 17 All as per item No- 11.005above but capacity 11 KV100 KVA. 18 All as per item No- 11.005 above but capacity 22 KV 400 KVA. 19 Servicing of existing LT electrical distribution/control panel of any size and capacity including cleaning of dust and debris, tightening of all connections, checking of contactors/relays, testing of insulation resistance, repair/replacement of defective control wiring (upto 1.5 sqmm copper) and faulty indicators (LED type), Testing and replacement of defective control MCBs upto 63A andensuring full operational status. Complete in all respects as per standard practice and directed by engineer-in-charge 20 Supply, jointing and testing outdoor cable end termination joint (heat shrinkable) suitable for 3 core 185 sqmm 22 KV XLPE cable suitable for earth system complete all as specified and directed. 21 Supply & fix heat shrinkable straight through joint 22 KV XLPE cable suitable for earth system of size 185 sqmm 3 core complete all as specified and directed. 22 M&L Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge or the plate at a depth of not less than 1.5 m below ground level, connected to and including galvanised eath strip 32 mm x 6 mm by means of bolts,nuts and check nuts and washers of galvanised steel. Gl pipe 40 mm dia light grade pipe for protection of G.l. earth strip both to be provided to the extent of 7.5 meters as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per elctrical plate No. 3 of SSR Part 1·2009 including PCC chamber made up of PCC 1:3 :6 type C1 & RCC Chamer cover of size 540x540x100 mm made with 1:2:4 Type B1 using 6 mm round MS bar & 8 mm MS bar for handle , 20 mm dia medium grade G.I. Watering pipe from top edge of the earth plate upto M.S funnel with wire mesh provided inside the concrete earth pit for watering arrangement including excavation and earth work in any type of soil and testing complete all as specified and directed. 23 Installation testing and commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installation on cable trench housing cubicle Type, free standing Panel CPRI approved working on 440 V 3 phase 50 Hz, AC supply with aluminium bus bar suitable for 800 Amps fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted asper the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams GE/1668/901:(a) Volt meter 0 – 500 Volt with selector switch – 01 (b) Ammeter 0.1000 Amps with CTs and selector switch – 01. (c) Indication Lamp assembly – RYB LED – 01 set.Incomer : 630 A 4 pole, ACB-02 Nos. Bus coupler : 630 A 4 Pole, ACB -01 No. Outgoing feeders :3 Pole, 315 A MCCB, 50 KA -05 Nos, 4 Pole, 250 A MCCB,35 KA-03, 3 Pole, 200 A MCCB, 35 KA -02Nos, 4 Pole, 100 A MCCB, 25 KA-01 Nos. Panel fabrication & Bus bar for above feeders. (Note- LT Panel with components as above shall be issued under Sch B free for fixing ) 24 Installation, testing & commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installationon cable trench housing cubicle type, free standing, panel CPRI approved 3 phase, 50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per specifications and having the following details and as shown in single line diagrams GE/1968/901 : (Note- LT Panel with components as above shall be issued under Sch B free for fixing )Incomer:160A, 4 pole 25 KA, MCCB with S/C adjustable, O/L & E/F thermal magnetic releases - 01 eachOutgoing Feeders:160A, TP, 25 KA, 415 VoltMCCB withS/C & adj. O/L& E/F thermal magnetic releases - 05 Nos25 KVAR APFC Compartment80A, TPN, 25KA - 1 No, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic release 01 Each8 Stage APFC Relay16A, TPN, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 5 KVAR Capacitor) 01 Each32A, TP, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 10 KVAR Capacitor) - 02 NosCapacitor MD - XL 25 Installation testing and commissioning diesel engine/driven generating set of capacity 30 KVA (24 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories :(Note- DG Setwith components as above shall be issued under Sch B free for fixing ) (a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling 26 (f) Toggles switch for idle running(g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 30 KVA/24 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 MAKE: Kirloskar C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 30 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 27 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS: (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 30 KVA DG Set per CPCB Norms 28 Installation testing and Commissioning of INDOOR TYPE ENCLOSURE with angle iron pedestal frame & including steel structure required for installation on cable trench housing cubicle type, free standing, panel CPRI Approved working on 440 V, 3 Phase50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams Ge/1968/905 (Note- LT Panel with components as above shall be issued under Sch B free for fixing )INCOMERFP pole MCCB 250 Amps 35 KA – 02 NosOut Going feeders:TPN pole 16A MCCB, 25 KA – 02 NosTPN pole 20A MCCB, 25 KA – 02 NosTPN pole 63A MCCB, 25 KA – 02 NosTPN pole 100A MCCB, 25 KA – 02 NosTPN pole 125A MCCB, 30 KA – 02 Nos3 KVAR capacitor duty contractor – 02 Nos5 KVAR capacitor duty contractor -02 Nos20 KVAR capacitor duty contractor -02 Nos30 KVAR capacitor duty contractor -02 Nos40 KVAR capacitor duty contractor -02 Nos8 stage APFC relay – 02Nos 29 Installation testing and commissioning diesel engine/driven generating set of capacity 160 KVA (128 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories : (Note- DG Set with components as above shall be issued under Sch B free for fixing ) complete all as specified and directed.(a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling(f) Toggles switch for idle running 30 (g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 160 KVA/128 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 160 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 31 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS:(i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.(E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 160 KVA DG Set per CPCB Norms 32 Installationtesting & commissioning of indoor cubic type, free standing floor mounted including of steel structure required for installation on cable trench with base frame, AMF panel CPRI approved on 440 V 3 phase 50 HZ, AC supply. It shall be extendible at both ends, with aluminium bus bars 200 amps capacity fully compartmentalized dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank procress & suitable for IP-52 protection, as per section and having the following details and as shown in single line diagrams GE/1968/094 , complete all as specified and directed.( Note - AMF panel with components shall be issued under Sch B free for fixing ).Incomer100A 4 pole, 25 KA motorized MCCB – 01 NoOutgoingTPN 63 A MCCB, 25 KA – 02 NoTPN 32 A MCCB, 25 KA, 32 A MCCB, 25 KA – 2 NoPanel Fabrication & Busbar for above feeder 33 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 315 A MCCB,50 KA- 01 NoOutgoingTPN 63A MCCB, 25 KA – 08 NosPanel Fabrication & Busbar for above feeder 34 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch B free for fixing )IncomerFP 250 A MCCB,35 KA- 01 NoOutgoingTPN 63A MCCB, 35 KA – 08 NosPanel Fabrication & Busbar for above feeder 35 Supply, Install, testing, and commissioning of outdoor type, enclosure double door with angle iron pedestal frame & including steel structure required for installation on cable trenches, housing cubical type free standing,panel working on 440 volts, 3 phase 50 hz, AC supply with aluminium bus bar,full compartmentalised dust proof and vermin proof 3.15 thcik CRCA sheets steel enclosure, painted as per the 7-tank process & suitable as per IP-56 protection as per specification and having the following details and as shown in single line diagrams GE/1968/901 (Panel for 3 Alexander Road) complete all as specified and directed.a)MCCB 160 amps 4 pole, 25 KAbreaking capacity with short circuit adjustable overload& earth fault thermal magnetic release-8 Nos, CTs, ammeter with selector switch, voltmeterwith selector switch(Incomer)-01 Nos Bus bars: 250 A TPN aluminium Busbars suitable for 25kA for 1 Sec Outgoing Feeders :a) MCB TP 40 Amps 25 KA breaking capacity with short circuit adj overload and B/F thermal magnetic releaseb) Suitable enclose IE panel fabrication and bus bars for above MCB feeders. c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job 36 Supply, installation, testing and commissioning of readymade 08 way TPN DB metal doorwith 200A rated busbar with following (CAT Part NoDBTPN008DDS of L& T or equivalent in Siemens/Legrand/C&S)Incomer: (a) MCB 4 Pole 60 Amps, 415 Volts breaking capacity 10kA 02 Nos (BB30630C of L &T)Outgoing feeders:(a) MCB TP 25 Amps, 415 Volts breaking capacity 10kA 04 Nos (BB30250C of L &T)(b)MCB SP 10 Amps, 230 Volts breaking capacity 10KA 04 Nos (BB10100C of L &T) 37 Supply, installation, testing and commissioning of outdoor line up of 11 KV RMU type compact panels, consisting of following :-11 KV 630 Amps 20KA for 3 sec. air/gas insulated RMU panel with 1 No incommingmanullay operated VCB and 02 Nos outgoing load break switches,CTs for protection as per detils given in specification complete in all respect inverse time over, current, short circuit & earth fault with instantaneous elements relay.Indication : ON, Off, Trip, R.Y.B. with facility for transformer buchholz relay trip with terminals for 230V AC supply aluminium Busbars 630 Amps, 11KV, TP busbars for 20 KA for 1 sec with PCC foundation all as per required & as per manufacturer instructions. complete all as specified and directed. 38 Supply, installation, testing and commissioning of 11KV 50/5 Amps ratio oil immersed vacume impragnated single phase current transformer with VA burden of 15 for class 0.5 class SP 10 with 25 KA short circuit rating for 1 second complete with all structure base and mounting arrangement as indicated and also as per specification and technical particulars. 39 Supply,Installation , testing and commissioning of outdoor line-up of 22 KV RMU type compact panels, consisting of : 22 KV 630A, 20KA for3 sec Air/Gas insulated RMU panel with 1 No Incomer & 2 Nos outgoing: 22 kV, 16 kA for 1 second, 630A HT VCB with 3 nos. resin cast 22000V/ sqrt. 3/ 110V/ sqrt. 3 withdraw-able PTs, HT and LT fuses ffor PTs, In comer 3 nos 50/1A & in outgoing 9 Nos. 20/1A CTs-core-1: class 0.5 CTs for metering, Core 2 : class 5 P10 for protection, inverse time over current, short circuit & each fault with intantenous elements relay, master trip, R.Y.B spring charge, trip circuit healthy. ON-OFF Push buttons illumination lamp, hooter, industrial socket with switch, space heater with thermostat, control MCB & control terminals etc complete all as specified and directed. 40 Laying only in trenches or fixing on wall or pole LT XLPE UG cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (Heavy duty) with standard aluminium conductor 1100 volt grade of the follwing size including provision of necessyar lugs and glands as under : (Note- LT under ground cablementioned below at sl No (a) to (i) shall be issued under Sch Bfor laying/fixing ) 41 a) 300 sqmm 3.5 core 42 b) 240 Sqmm 3.5 core 43 c) 185 sqmm 3.5 core 44 d) 150 Sqmm 3.5 core 45 e) 120 Sqmm 3.5 Core 46 f) 50 Sqmm 3.5 Core 47 g) 35 Sqmm 3.5 core 48 h) 25 Sqmm 4 core 49 i)16 Sqmm 4 core 50 Supply and fixing and installation of fire extinguisher CO2 Map cap of 4.5 Kg as per IS 2878 Complete all as specified andas directed. 51 MS fire bucket 13 Ltr Cap of fire approved quality painted red filled with sand Complete all as specified andas directed. 52 Supply only hand gloves for safety,suitable for 22 KV grade. Complete all as specified andas directed. 53 Supply only hand gloves for safety,suitable for 11 KV grade. Complete all as specified andas directed. 54 MS padestal stand duly painted for suspending fire buckets 55 M&Lfor shock treatment chart in different languages (english, Hindi, Marathi) 56 Supply and placing of first aid box as per specification 57 Cable route marker made of galvanised iron supporting with GI angle for HT/LT cable root marking 58 M&L for Road cuttingby core cutting machine not less than 0.6 mtr wide and .45 mtr depthfor laying RCC and GI Pipe for the the HT/LT cable and making good surface with PCC 1:4:8 type D-2 using 40 mm graded stone aggergatecomplete all as specified and directed. 59 Supply and erect steel tubular poles swaged welded poles complete for two pole structure with MS base plate, MS pole cap, bolts nuts, and screws as per IS 2723 ( part II ) 1980 made out MS tyubing duly painted with metal primer and two coats of aluminium paint over exposed surface and Making 4 Nos of strips of 30 cm wide in alternate black and yellow colourup to 1.5 mtr hight, Writing pole number and voltage level encompassed by circle of suitable diausing two coats of synthetic enamel paint over a coat of red oxide zinc chrome primerbottomand one coat of red oxide and two coats of bituminous paint for embedded portion as specified type 410 SP - 31 of 9 mtrs long complete all as specified and as directed. ( Note- Excavation / earth work , PCC will be measured and paid separately ) 60 S&F FRP box,MCB SP 6 Amp-01 No and clamps made out of FI 32x6mm and GI nut bolts. Complete all as specified andas directed. make-syntex Model GSJB-3020 with 4 connectors or eqvt 61 S&Ftimer switch box fabricatedout of 16 SWG CRCA sheet with mounting arrangement duly powder coated consisting of the following :-a) Timmer astronomical-1, b) Power contactor 63 Amps make- -01 Noc) connector 100 Amps 230 Volts - 03 Nosd) MCB TPN 63 Amps 415 V - 01 Noe) Control fuse 2 Amps -01 NoComplete all as specified andas directed. 62 S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for suitable for 22 KV working pressure. Complete all as specified andas directed. 63 S&F Disc type porcelain, vitreous, white, brown or green i nsulator includingone galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 145 mm height, 255 mm dia ball and socket type Two-in-assembly for tension with tension clamps for conductor suitable for 22 KV working pressure. Complete all as specified andas directed. 64 Supply and lay rubber mat 2 mtr x 1 mtr,10mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 65 Supply and lay rubber mat 2mtr x 1 mtr,30mm thick 22 KV grade AC elect supply. Complete all as specified andas directed. 66 Supply and lay rubber mat 2mtr x 1 mtr, 19mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 67 Supply, jointing and testing Outdoor type cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 68 Supply, jointing and testing Outdoor type cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 69 Supply, jointing and testing indoor typeCable jointing kit for 11 KV (Earthed)grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size ofsize 150 sqmm 70 M & L for discharge rod PVC coated suitable for 22KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 71 M & L for discharge rod PVC coated suitable for 11KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 72 Supply onlyEngine oil, multi grade premium Genuine oil 15W40 as per manufacturer recommendations in DG sets complete all as specified.Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 73 Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 74 Supply and fill for genuine coolant in 5 litres plastic sealed containerfor topping up in Radiator of DG set located at different locations complete all as specified and as directed. 75 Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed. 76 Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed. 77 Maintenance and servicing for Comprehensive C Check maintenance service for DG Set of capacity 160 KVAincluding dismantling, cleaning, filter & oil replacement, fuel system overhauling, radiator inspection, valve clearance adjustment, load testing, FIP Caliberation, checking and repair of radiator for leakage,and detailed service report submission as per OEM recommendation to DG setincluding replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 100 KVA DG set installed at Southern Command Signal Centrecomplete all as directed by Engr- in- Charge.Note:- (i)Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii)The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v)Work shall be carried out at site at different location Work to be carried out by OEM certified technician or approved equivalent. Service reports to be submitted post-maintenance 78 All as per item no. 11.066here-in-above but of capacity 100 KVA. 79 All as per item no. 11.066here-in-above but of capacity 30 KVA. 80 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 160 KVA. compete all as specified and as directed. 81 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 100 KVA. compete all as specified and as directed. 82 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 30 KVA compete all as specified and as directed. 83 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 160 KVA compete all as specified and as directed. 84 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 100 KVA compete all as specified and as directed. 85 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 30 KVA compete all as specified and as directed. 86 S & F air filter element suitable for capacities ofD. G . Set 160 KVAcompete all as specified and as directed. 87 S & F air filter element suitable for capacities ofD. G . Set 100 KVAcompete all as specified and as directed. 88 S & Fair filter element suitable for capacities ofD. G . Set 30 KVAcompete all as specified and as directed. 89 S & F by-pass filter element with O ring suitable for 160KVA DG set compete all as specified and as directed. 90 S & F by-pass filter element with O ring suitable for 100KVA DG set compete all as specified and as directed. 91 S & F by-pass filter element with O ring suitable for 30KVA DG set compete all as specified and as directed. 92 S & Ffan beltcomplete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 93 S & F belt for battery charging alternator complete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 94 S & F rubber hose pipe set for water circuit with clamps complete suitable for 100KVA DG set complete all as specified. 95 M & L for carrying out repairs to AMF panel of 100 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measuredand paid seperately under relevant items. 96 S & Ffor digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent. 97 S & Ffor digital type Ammeter 0-200 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent 98 S & Ffor digital type Voltmeter 0-500 Volts 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent. 99 S & F for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified. Make: Rishab/ L&T/AE/ Legrand or equivalent 100 S & F for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron. 101 S & F for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol 102 Supply and fix for lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and as directedMake- Exide/Amaron. 103 Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacementup to desired level of transformer oil capacity and Oil circuit brekar complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] 104 Supply only breather assembly as per existing size, shape and specification complete for capacity 315 KVA , 11/0.433 Voltstransformers including fresh blue silica gel 105 Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of snthetic enamel paintby spray paint incl writing SM No/MES No , capacity of transformer of 315KVA capacity all as directed by Engr-in-Charge 106 Supply and fix for switch air break gang operated HT 11 KV Volt grade out door type, triple poleof capacity 200 amps rating mounted on Polymer based 09 insulator with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame horizontally mechanicallyoperated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed. (Universal/Pactil) 107 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulatorswith steel frame 200 Amps capacity, siutable for 11KV, HT system,out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed. Make : Universal/National or its equivalant.Note for Item No 11.094 & 11.095 : The work to be carried out in existing structure. Hence continues shut down will not be available. According to the availabity of shut down timing the contractor shall manage the work in quoated rate only. 108 M&L for Painting of HTpoles including cross arms complete with synthetic enamel paint including filling cavities with filler one coat after cleaning all dust/rust including writing the pole No. and all as directed by Engr-in-Charge 109 M & L for Servicing of Molded Case Circuit Breakers (MCCBs)/ACB in existing panelsincluding cleaning, tightening of connections, checking of mechanical operation, insulation resistance testing, functional testing, lubrication of moving parts, and recording of test results. All tools, materials, labor, and consumables to be included for following capacity:- 110 630 Amps ACB 4 pole,415 volt manual drawout type with micro processor release 111 3 Pole 350A MCCB, 36 kA 112 3 Pole 250A MCCB, 36 kA 113 3 Pole 160A MCCB, 36 kA 114 3 Pole 125A MCCB, 36 kA 115 3 Pole 100A MCCB, 36 kA 116 3 Pole 63A MCCB, 36 kA 117 3 Pole 32A MCCB, 16 kA 118 S & F in repairs ACB 4 Pole, current rating 630 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of(Make : L & T Cat No CM96111OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as directed. 119 S & F for 4 pole MCCB400 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 120 S & F for4 pole MCCB 250 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 121 S & F for4 pole MCCB 200 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 122 S & F for 4 pole MCCB 160 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand/ Schenedier)complete all as specified and as directed. 123 S & F for 4 pole MCCB 100 /125 A, having breaking capacity 36 kA (Make :L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 124 S & F for 4 pole MCCB 63 A, having breaking capacity 10 kA, (Make : L & Tor equivalent in Legrand / Scheneider) complete all as specified and as directed. 125 M&Lfor switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and MS galvanized steel frame with operating mechnizing worked from ground level including operating rod of size 32 mm dia / 25 mm dia as reqd GI medium grade for current rating upto 200 Amps 22000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified complete all as specified and as directed. 126 S&F for drop out fuse assy single pole 22KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures complete all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 127 S&F fordrop out fuse assy single pole 11KV , 25 Amps rating complete expulsion fuse element mounted on four / two pole structuresincluding dismanteling old existing UNSV all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 128 S&F for pin type insulator, HT Polymer/porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 22000 volts including dismantling insulator any type / any sizecomplete all as specified and as directed. 129 S&F for insulator disc type single disc assembly, ISI marked working pressure 22000 volts, porcelain vitreous white, brown, or green size 145 mm high and 255 mm dia ball and socket with tension clamp to suit the size of conductor (ACSR)including dismantling insulator any type / any size complete all as specified and directed. 130 M&L for aluminium strip 25 x 4 mm of required lengthwith color sleeves for jumpering purpose in 11 /22 KV DP/FPincluding taking down existing aluminium conductor etc complete all as per the direction of Engineer-in-charge. 131 S & Ffor gasket set of 22/11 KV 100 KVA to 400 KVA transformer complete all as specified and directed. 132 S& F for silicagel breather complete all as specified and directed. 133 M&L for Testing of exisiting earthing resistance with suitable digital Earth tester complete all as specified and directed 134 S&Fepoxy based insulator with screw, nuts and bolts fixed on OH reservior roof top and on shaft surfaces not more than 2.00 m apart from fixing aluminium or GI strip complete with fixing arragnment complete all as specified and directed. 135 Supply, laying,testing and commissioning or passing through pipe,XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area of size 3 core 150 Sqmm 136 Laying in trenches and testing cable XLPE insulated screen PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 22000 volts grade of size 3 core X 185 sq mm suitable for earthed system etc complete.(Note-HTcablewill be issued under Sch B free for fixing/laying). 137 Supply, installation and testing complete electronic digital type water level indicator devicesuitable for operating at 230V +/- 10%, 50 Hz sysytem having 150mm size digital display and alarm at low/high level of OHT / sump.The complete unit fitted in MS sheet base in two boxes, one box to be installes at sump/OHR and second at pump house bothunit to be connected with flrxible copper cable of .5 sqmm 8 pair and length from sensor to pump house building or OH reservoirs of 21 mtr and 15 mtr staging,All enclosed in sheet metal enclosures of 02mm thick with hinged door and locking arrangement and support GI wire/PVC pipe etc properly laid or fixed on wall / surface all as directed by Eingr-in-charge.Make- SECO type DDS-6 or equivalent model in Schneider/ Havels/ L&T. 138 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 40 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 139 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 50 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 140 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 75 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 141 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 90 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 142 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 110 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 143 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 120 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 144 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 160 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 145 MISC ITEMS OFEXTERNAL WATER SUPPLY 146 Laying and testing ductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 150 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 150mm bore will be issued under Sch B for fixing only. (Rates of DI fitting required for sch B items will be included in the quoted rates) 147 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 200 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 200mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 148 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 100 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 100mm bore will be issued under Sch B for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 149 Supply, fix and testing dual type non return valve of 100 mm bore, cast iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent IS. Complete all as specified andas directed. 150 Supply, fix andtesting gun metal dual type non return valve of25mm bore,iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent ISComplete all as specified andas directed. 151 M& L for DI fittings & specials such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end taperingbellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for run lead joints ofsize from 80 to 200 mm bore. Complete all as specified andas directed. 152 Supply, fix and testing GM gate/globe valves heavy duty conforming to IS 778 with iron wheel head screwed both ends suitable forfollowing sizes ofbore:-Complete all as specified andas directed. 153 25 mm bore 154 40 mm bore 155 50mm bore 156 80 mm bore 157 Install,testingand commissioning of LT distribution outdoor typepanel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 3.15 mm thick with MS angle iron of size 50x50x6 mmto be mounted on floor / wall suitable to accommodate common bus bar and the following accessories:(a) MCCB TPN 100 Amp 25 KA 415 Volt thermal adjustable- 1 No. (b) Copper bus bar 400 Amps. 4 runs duly coloured PVC sleeve (c) Fully automatic star delta starter suitable for 7.5 HP pump set 440 V Model MK-1 Make L and T with electric connection - 02 No. (d) MCCB TP 10 KA 63 Amp - 02 N os (e) MCB DP 32 Amps - 02 Amps(f) Ammete 0-200 amps with CT & selector switch - 01 No (g) Voltmeter 0-500 V with selector switch - 01 No(h) lndiating lamp - LED type RYB ) Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 158 Install test and commissioning of LT distribution panel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 Wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 2 mm thick with MS angle iron of size 50x50x6 mm to be mounted on floor / wall suitable to accommodate common bus bar and the following accessories :- (a) MCCB TPN 63 Amp 25 KV 415 Volt - 1 No.(b) Copper bus bar 400 amp - 4 runs duly coloured PVC sleeve (c) DOL starter suitable for 3.0 HP pump set 440 V Model MK-1 make L&T with electric connection :- 2 No. (d) MCCB TP 40 Amp 10 KA 415 Volt-2 No (e) MCB DP32 Amp - 2 No.(f) Ammeter 0-100 Amp with CT and selector switches – 1 No(g) voltmeter 0-500 V with selector switch 01 No (h) Indicating lamp LED type RYB – 01 Set.Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch B free for fixing ) 159 Install, Test, Commissioning of open well submersible pump set 80x80mm for pumping clear water at ambient temperature from UG sump for delivering 25 m3/hours at a total head of 40 mtr complete with suitable electric motor 7.5 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 80 mm dia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection.Complete all as specified andas directed. ( Note- submersible pump setshall be issued under Sch B free for fixing ) 160 Install, Test, commissioning of open well submersible pump set 25x25 mm for pumping clear water at ambient temperature from UG sump for delivering 165 LPM at a total head of 25 mtr complete with suitable electric motor 3.0 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 50 mmdia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection .Complete all as specified andas directed.( Note- submersible pump set shall be issued under Sch B free for fixing ) 161 Installation, testing and commissioning of 750 LPM capacity head105 M end suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 ± 10% 50 Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller includsive of suitable star delta starter inclding cable from starter to motor drawn through flexible metallic conduit pipe starter and suitable PCC foundation etc complete as per manufacturers recommendation. Complete all as specified andas directed. ( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 162 Installation, testingend suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 Volt + 10%, 50Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller inclusive of suitable star delta starter inlcuding cable from starter to motor drawn through flexible metallic conduit pipe following capacity inclusive of starter and PCC suitable foundation as per manufacturers recommendations. Capacity 1460 LPM, Head-100M. Complete all as specified andas directed.( Note- Centrifugal pump set shall be issued under Sch B free for fixing ) 163 Supply,install,testing & commissioning of end suction type centrifugal pump set, multistage,bronze impellor,water supply, assembled and tested for rated efficiancy complete with energy efficient motor conforming to IS 12615 common base frame,coupling guard and mechanical seal suitable for operation on 415 volts+/- 10%, 50HZ AC supply of capacity 1500 RPM, 700 LPM, head 70mtr inclusive of PCC foundation ,suction & discharge of pipes as per manufactures instruction.Complete all as specified andas directed.Note:- Cost of suction and discharge pipes upto 7.50 RM long each shall be deemed to be included in the rate quoted. 164 Supply installation,commissioning and testing ofDOSING SYSTEM ( MODEL: ADS-I of ALTOCH) consisting of 40 liter - 100 liter PE/FRP LID & leval gauge along with agitator with shaft and blade in plastic. mounted on tank Complete all as specified andas directed.. (Make : ALTOCH or Equvivalent as approved by Accepting officer) 165 S&F Cast iron body foot valve of size 150 mm bore flanged as per IS 4038 , including nuts, bolts, washers and rubber gaskets, complete all as specified & as directed. 166 Supply installation,commissioning and testing ofdosing pump model 96NGQ51 of Decrain,high presser single head gear motored adjustable dosing pump of following specification:-.(a) Adjustable high presser -0 to 100 PSI (b) Power-230v, 50HZ (c) RPM-44(d) HP 1/10 fractional(e) Out put -2 U.S GPD to 40 USGPDComplete all as specified andas directed.(Make : Decrainor Equvivalent as approved by Accepting officer) 167 S & F Cast iron air release valves with two air outlets of 50mm bore and fixing of cast iron pipe including necessary fittings. Complete all as specified andas directed. 168 Supply,Laying and jointing & testing DI pipe with socket & spigot ends, class K 7 with cement morter lining in side the pipe and zinc coatedout side asper IS 18329/2000 in standard length suitable for push onwith rubber gasket joints(tyton joints) laidintrenchesof size 150 mm bore. Complete all as specified andas directed. 169 Supply, laying, jointing and testing Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9 conforming to IS-8329of following sizes, in any length, laid in trenches/ pipe supports etc, pressure testing after laying complete a per IS-12288 including styrene butadiene rubber gasket joints, complete all as specified and as directed.NOTE: Tyton joints required are deemed to be included in the unit rate quoted. 170 100 mm bore pipe 171 200 mm bore pipe 172 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne 60 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set 173 (f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set(h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 174 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne39 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set(f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CTs & selector switch 0-100 A cap- 03 Set 175 (h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 176 MISC ITEMS B/RWORKS 177 S&F factory made Steel fibre reinforced manhole frame and cover 100mm thick of size 1.20m x 0.60m complete all as specified and directed. 178 M & L for recharging of normal earth pits by excavating the earth at a radius of 600mm from the centre from the earth pit and at a depth of 900mm after removing the earth chambers and accessories carefully and keeping aside for reuse including adding and spreading chemicals as given below in 75mm layers each as ground level and watering, refixing the earth chambers and accessories after allowing the soil to settle down complete all as specified and directed by Engr-in charge.(a) Charcoal 10 kg. (b) Salt 10KgNote :- Excavation , refillingis included in quoated rate 179 Supply and fix for repairs earth chambers by demolishing unserviceable earth chambers and fixing new chambers ofPCC 1:3:6 type C1bed and chamber RCC 1:2:4 type B1of size (600X600X200)mm and thickness 120 mm andand CI cover 10mm thick hinged to CIframe duly groted with PCC, complete all as specified and directed. 180 Construction of valve chamber with PCC solid block masonry grade C-5, 200mm thick having 150mm thick hard core and PCC (1:4:8) type D-2 (using 40mm graded stone aggregate in foundation, including excavation & earth work in any type of soil, internal & external plaster to walls in cement morter 1:6, 15mm thick complete all asspecified and shownon drg No CEPZ/93/TD/20M Sht No 1/1 of following internal dimension:- 181 0.60mtr x 0.60mtr x 0.60mtr 182 1mtr x1mtr x1mtr 183 1.2mtr x1.2mtr x1.2mtr 184 Cutting the existing water line 300 mm dia for inserting Tee Reducer bend, coller etc complete ( Note : CI specials, lead joints excavation and earth work shall be measured and paid separately under relevant item of this schedule ) 185 Moblization of necessary equipment & manpower at site of work to carry out plate load test for determination of K Value (Modules of subgrade reaction) of Soil in the field in accordance to IS 9214-1979, complete in all respect, as specified & directed with & including following operations.(a) Digging out Pit of desired size & depth.(b) Placing & arranging Poclain, as per requirement & recording the settlement data with 03 Nos of dial Gauge in Horizontal Plain Placed at 120 degree, using Hydraulic Jack with proving ring & dial gauze of least count 0.002 mm & submission of report in sixtulicate determining modulus of subgrade reaction K Value.
Contract Date: Feb 06, 2026 Contract Value : 8.36 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
Maharashtra View Result →
31.
Educational and Research Institute #9361414 Technical Bid
Supply And Insttalation Of Fitter Trade Tools Equipment Machinery At Consignee Location , Steel Rule With Metric & British Graduation , Try Square. , Caliper Inside Spring Type. , Caliper Hermaphrodite Spring Type , Caliper Outside Spring Type , Divider Spring Type , Scriber Length 150 90 ° Bend And Straight , Centre Punch , Screw Driver , Hammer Ball Peen With Handle 500 Grams , Hammer Ball Peen With Handle. 200 Grams , File Flat - Second Cut , File Flat Smooth , File Half Round Second Cut , Hacksaw Frame Fixed Type , Safety Goggles. , Dot Punch , Straight Edge Steel , Stud Extractor Ezy - Out , Combination Set , Micrometer Outside.0 To 25 , Micrometer Outside.25 To 50 , Micrometer Outside. 50 To 75 , Micrometer Inside With Extension Rods. , Vernier Caliper , Vernier Height Gauges , Vernier Bevel Protractor Blade With Acute Angle Attachment , Screw Pitch Gauge Metric , Wire Gauge, Metric Standard. , Angle Plate , Portable Hand Drill (Electric) , Drill Twist Straight Shank Dia- 3Mm, 4Mm, 5Mm, 6Mm, 7Mm, 8Mm, 9Mm, 10Mm, 11Mm, 12Mm , Drill Twist Taper Shank Dia- 3Mm, 4Mm, 5Mm, 6Mm, 7Mm, 8Mm, 9Mm, 10Mm, 11Mm, 12Mm, 13Mm, 14Mm, 15Mm, 16Mm, 17Mm, 18Mm, 19Mm, 20Mm. , Taps And Dies Complete Set In Box. , File Knife Edge Smooth , File Feather Edge Smooth , File Triangular Smooth , File Round Second Cut , File Square Second Cut , File Triangular Second Cut. , File Flat Second Cut Safe Edge. , File Flat Bastard , File Flat Bastard. 300Mm , File Half Round Second Cut. , File Half Round Bastard. , File Round Bastard. , File Hand Second Cut. , File Card./Wire Brush , Pliers Combination Insulated , Wooden Handle Forged Soldering Iron Copper Bit. 350 Grams 220 ,250Watts , Spanner- Double Ended Size 6X7, 8X9, 10X11, 12X13, 14X15, 16X17, 18X19, 20X22 , Spanner Adjustable Length (L): 150 Mm , Interchangeable Ratchet Socket Set Socket Size Dr Hex9,10,11,12,13,14,15,16,17,18,19,20,21,22,24,27,30,32 Mm Inch, , Double Ended Tubular Box Spanner Set With Tommy Bar. Sizes In Mm: 6X7, 8X9, 10X11, 12X13, 14X15, 16X17, 18X19, 20X21, 22X23, 24X25. , Glass Magnifying , Clamp Toolmaker , Hand Reamer Set (Taper Pin Straight Flute) Size In Mm –5, 6,8,10,12 Mm , Machine Reamer Parallel (Helical Flute) , Scraper Flat , Scraper Triangular , Scraper Half Round , Chisel Cold Crosscut& Diamond Point. , Drill Chuck With Key , Pipe Vice 100 Mm , Adjustable Pipe Die Set Bsp Size In Inch 1,3 Or 4 -Inch , Wheel Dresser (One For 4 Units) Star/Dresser With Holder , Machine Vice - Swivel Base 100 Mm , Machine Vice - Swivel Base 125 Mm , Sleeve Drill Morse 19Mm, 24.2Mm, 32.2Mm, 45.2Mm, 160Mm, 194Mm, 240Mm, 300Mm , Vice Bench 75 Mm , Almirah. , Lockers With 8 Drawers (Standard Size). , Fire Extinguisher (For 4 Units) , Fire Buckets. , Machine Vice. , Wing Compass. , Torque Wrench (Standard/Ratchet Type) , Power Tools For Fastening , Different Profile Gauges (Plate Type) - For Demonstration , Knurling Tool (Diamond, Straight & Diagonal) , Indexable Boring Bar With Inserts , Temperature Gauge , Dowel Pin (Straight) , Standard Tap Screws , Lapping Plate , Drill Gauges , Cast Iron Globe Valve (Flanged Type) , C.I. Sluice / Gate Valve (Flanged Type) , Slip-On Forged Steel Flange , Pipe Threading Die With Handle , Pulleys (For V-Belt Or Flat Belt) , Hollow Punch Hole Diameter (In Mm):5,7,9,12 , Drill Drift (May Be Manufactured In- House) , Lifting Sling , Bearing Extractor , Pulley Extractor , Trammel , Pocker , Prick Punch , Mallet. , Aviation Snips Straight Cut , Flat Headed Hammers With Handle. , Planishing Hammer. , Snip Bent Left Cut , Stake Hatchet With Leg. , Stake Grooving. , Slip Gauge As Johnson Metric Set. , Gauge Snap Go And Not Go Set , Gauge Plug (0-5,5-10,10-15,15-20,20-25,25-30,30-35,35-40,40-45,45-50, 50-55) Set Of 11 Pics. , Gauge Telescopic Set. , Dial Test Indicator On Stand , Sine Bar , Dial Vernier Caliper. (Universal Type) , Screw Thread Micrometer With Interchangeable. Pitch Anvils For Checking Metric Threads 60. , Depth Micrometer. 0-25 Mm , Digital Vernier Caliper. , Digital Micrometer Outside. , Comparators Gauge - Dial Indication With Stand And Bracket. , Engineers Try Square (Knife-Edge) , Surface Roughness Comparison Plates , Digital Vernier Caliper , Vernier Bevel Protector , Carbide Wear Block. Size 05-1000Mm , Lathe Tools H.S.S. Tipped Set. , Lathe Tools Bit. W 6 Mm , Lathe Tools Bit. W 8 Mm , Lathe Tools Bit. W 10 Mm , Arm Strong Type Tool Bit Holder. Right Hand 80Mm. , Arm Strong Type Tool Bit Holder. Left Hand 80Mm. , Arm Strong Type Tool Bit Holder. Straight Hand 80Mm. , Stilson Wrenches/Pipe Wrerch , Pipe Cutter Wheel Type. , Pipe Bender Machine Spool Type With Stand Manually Operated. Capacity -25Mm. , Adjustable Pipe Chain Tonge To Take Pipes L 350Mm , Adjustable Spanner. 380Mm , Drilling Machine Bench 0-12 Mm Capacity Motorized With Chuck & Key. Capacity In M.S : 12 Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Maharashtra View Result →
32.
Drinking Water Supply and Sanitation #9332284 Technical Bid
Tender For Additional Facility To New Bus Stand In Mmc; 1 Installation of Vertical Bored cast in situ RCC piles of following diameter in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap.( Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately ) 2 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 3 Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. 4 Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 5 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means 6 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require onlynominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener,side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 7 Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means 8 Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 9 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 10 Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with allnecessary accessories such as J/V bolt and nuts of suitable length with suitablebitumen washers complete complying with standard specification and as directed bythe departmental officers. 11 Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications 13 upplying and laying of Interlocking Paver Block Stone 60mm thickOver a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers. 14 Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator andconsolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. 15 Wiring with 2 x1.5 sq.mm.PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour withcontinuous earth wire connection of 1.5 sq.mm copper wire forOpen MS conduit Light point / fan point (for electronic regulator) ( 5 points / Coil) Higher End (SD-235) 16 Supply and fixing of single box type 40 W LED fitting (Philips / Havells / Eq) with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed Copper leads from terminals to the fitting (SD-88). 17 supply and fixing of 18W LEDround type Recessedfitting with LED (Higher end) on false Ceilingwith suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting (SD-452). 18 supply and fixing of 40W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting (SD-448). 19 supply and fixing of 1200mm (48) sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end)with 300 mm down rod on the existingfan clamp . (SD-467) 20 Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End (SD-476). 21 Supply and fixing of 6 Watts LED Round Type Surface mounted Down Light with PVC unsheathed copper leads from terminal to the fitting (SOR -M-3018) 22 Supply and fixing of 7 segment 6 way triple pole neutral MCB distribution boardin sheet steel enclosure double door type with metal door with IP 42 protection with 63A 4 pole MCB isolator as incoming and 3Nos 63A DP RCCB as sub incomer and 18 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (The MCBDB andMCBs should be with Legrand / Hager make) (SD-560). 23 supply and fixing of 150W LED street light fitting with LED (Higher end) with 40mm dia. GI pipe (class B) with 1 no.40 mm GI bend complete on the existing post/ on wall with 1.5 sq.mm PVC unsheathed copper leads with MS clamps and withpainting . (SD- 539) 24 Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion withsuitable colour .(SD-414) 25 Supply and run of 2 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour (SD-57). 26 Supply and run of 4 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for 63A 4P MCB and 63A 3Phase DB. (SD-343). 27 Supply and Laying of 3.5C X 240 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good(SD -676) 28 Supply and providing cable end termination of 3.5Cx 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (SD-230). 29 Design, supply, fabrication, erection, testing and commissioning of 200 A dust and vermin proof floor mounting cubical type panel board of size not less than (size 11ft x 6ft x1ft ) made up of 16SWGCRCA sheet steel for outer body and stifferness doors and switches supports and supply and fixing of following intermounting switches with centre bus bar chamber and two rows of switches with cable adopter chamber for all swiches with two coats of quality paint over the coat of red oxide primer and superscription of incoming and outgoing feeder cable, details and 2 Nos. metalic danger board complete mounted on base channel(3X 1.5X1.5) irn frame work aupport with following switch as confirming to IS specification. 1. 40A FP isolator(LegrandHager make) (SR) - 18nos 2. LED pilot Lamp arrangement with switch and with multification meter with necessary CT connection complete - 1 No. The incoming 200 A Fuse units should be connected to the bus with 1 X 14 copper bus bar & 18 Nos. 0f 40 A FP isolator should be connected to the bys by 6 sa.mm (840.3) PVC insulated single core multisrand FRLS flexible cu wire. The switches should be properly earted by solid copper flat as per IE rules and CEIG specification. (Data- 10) 30 commissioning of 200 a dust and vermin proof floor mounting cubical type panel board of size not less than (size 11ft x 6ft x1ft ) made up of 16SWGCRCA sheet steel for outer body and stifferness doors and switches supports and supply and fixing of following intermounting switches with centre bus bar chamber and two rows of switches with cable adopter chamber for all swiches with two coats of quality paint over the coat of red oxide primer and superscription of incoming and outgoing feeder cable, details and 2 Nos. metalic danger board complete mounted on base channel(3X 1.5X1.5) irn frame work aupport with following switch as confirming to IS specification. 1. 40A FP isolator(LegrandHager make) (SR) - 18nos 2. LED pilot Lamp arrangement with switch and with multification meter with necessary CT connection complete - 1 No. The incoming 200 A Fuse units should be connected to the bus with 1 X 14 copper bus bar & 18 Nos. 0f 40 A FP isolator should be connected to the bys by 6 sa.mm (840.3) PVC insulated single core multisrand FRLS flexible cu wire. The switches should be properly earted by solid copper flat as per IE rules and CEIG specification. (Data- 11) 31 Supply & erection of 200A rated dust &verminproofcubicle panel board of size not less than 5x6x1.5made out of 16SWG CRCA sheet steel with bus bar chamber, cable chambers, switching consoles with hinged doors etc. with necessary stifners on suitable angle iron frame supports with wall mounting arrangements complete with the following accessories. 32 Supply and fixing of 12 Mtr Mini Mast suitable for 180 km/hr wind speed and siitable for mounting Max 6.of luminaires consisting of : Head Frame, Movable lantern carriage,Double drum Winch 6mm 316 Grade, S.S Hoisting ropes of 7/19 construction Flexible Multicore cable Trailing cable - 5core X 4sq.mm 1per mast Foundation Bolts & Nuts Anchor Plate & Template,Lightning finial Twin aviation light (GLS type), Power tool (Integral) ,Feeder Pillar for automatic operation, Casting of Foundation and Installation / Testing & Commissioning Supply, installation of 8Nos of 150W LED fittings with CG boxes and lamps. 33 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 34 Supply and Delivery of 3 Seater Waiting Area Sofa/Visitors Reception Heavy Chair in Stainless Steel.The rate is inclusive of the charges for cutting ,bending ,welding,grinding,polishing,conveyance,electrical charges,etc, 35 Supplying and erecting in position of following 500 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
33.
Rural Development #9331420 Technical Bid
Rate Contract Of Miscellaneous Item For Financial Year 2024-25 For Grampanchayat Haladwahi Tah.Chamorshi , Material , 4-4-1 Supplying, Installing, Testing And Commissioning Of 1 Kwp Off-Grid Solar Power Pack With Interconnecting Wires / Cables Up To 12 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 03 Nos.), C-10 Rated Lead Acid Battery Bank 12 V, 400 Ah (12V, 100 Ah X 4 Nos.) Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board , Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying & Erecting Single Phase, 240V, Street Light Control Panel Up To The Max Load Of 12Kw, Spn Mcb 63A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cc Foundation , 9 Mtr Hexagonal Gi Pole 8-8-2 Supply And Erecting 9M (Clear Height) Fixed Type High-Mast (Top-100Mm, Bottom- 200Mm) With Hexagonal /Round Bracket And Foundation Bolts Suitable For Max. 4 Nos. Flood Light Fixtures On Provided Foundation As Per Specification No. Oh-Pl/Opl (Excluding Luminaires). , 8-2-23 Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High-Mast Of The Same Manufacturer With 32A Tpn Mcb Incomer, 24Hr Astronomical Time Switch With Minimum 5 Years Battery Backup, Ip 54 And Ik10 Protection, 25 A Tp , 4-3-2 Supplying, Installing, Testing And Commissioning C-10 Battery With Capacity Of 12 V, 75 Ah With Duty Cycle 10-12 Hrs. Suitable To Charge On Pv Cell With Necessary Wiring Connections, Nut Bolts On Provided Stand With Five Years Warranty As Per Specification No. Esd-Sol/Bat , Supplying And Erecting Outdoor Pole Mounted Solar Monbock Panel 48W , 12 Moduler Metal Box , 8 Moduler Metal Box , 3 Moduler Metal Box , 12 Moduler Plate With Surface Plate , 8 Moduler Plate With Surface Plate , 3 Moduler Plate With Surface Plate , Celing Fan Regulator Single Module Type , 6A Switch , 16A Switch , 6 A Socket , 16A Socket , 16A Power Point Switch+ Socket Box , 16A Power Point Switch+ Socket Plate , 40A. 4P. Elcb , 40A. 2P. Elcb , 16A Sngle Pole Mcb , 18W Down Light Fall Celling Mounting , 20W Led Tube Light Fitting , 48 Inch Celling Fan , 8 Way Spn Double Door Db , 1 Sqmm Cu Flexible Wire , 1.5 Sqmm Cu Flexible Wire , 2.5 Sqmm Cu Flexible Wire , 4 Sqmm Cu Flexible Wire , 6 Sqmm Cu Flexible Wire , 2 Tr Ac With Out Door Unit , Exaust Fan , 25 Mm Pvc Pipe , Speaker Wire , Misculiance , Installation , Supplying And Erecting 12 M (Clear Height) Motorized High-Mast (Top -150Mm, Bottom- 360Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen - 10025 S 355/E350 & 3Mm Thickness, With Base Plate 25 Mm Thick X Od 520 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Arc Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 5Mm, Sg-Dg U Clamps, Double Drum With Assembly 250 Kg, 5X2.5 Sq.Mm. Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete As Per Specification No. Ohpl/ Hm (Excluding Luminaries) , Supplying, Installing, Testing And Commissioning Of 1 Kwp Off-Grid Solar Power Pack With Interconnecting Wires / Cables Up To 12 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 03 Nos.), C-10 Rated Lead Acid Battery Bank 12 V, 400 Ah (12V, 100 Ah X 4 Nos.) Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board , Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying, Installing, Testing And Commissioning Of 3 Kwp Off-Grid Solar Power Pack With Interconnecting Wires / Cables Up To 24 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 09 Nos.), C-10 Rated Lead Acid Battery Bank 24 V, 600 Ah (12V, 300 Ah X 4 Nos.) Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying, Installing, Testing And Commissioning Of 5 Kwp Off-Grid Solar Power Pack With Interconnecting Wires / Cables Up To 24V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 15 Nos.), C-10 Rated Lead Acid Battery Bank 24V, 300Ah X 4 Nos. (12V, 300 Ah X 8 Nos) Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Sound Sysetm (Amplifire, With All Set) , ???? , Green Mat , Chair , Wheel Chair , Table , Almari , Cctv Camera Set , Dust Bin , Solid And Liquid Waste Management Equipment
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
34.
Communications and Information Technology  #9286869 Technical Bid
Tender For Erection Of 3 Nos Of Rtt Along With Rcc Base In Amravati Ssa.; 1 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 3 Centering and shuttering including strutting, propping etc. and removal of form for : 4 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 5 Columns, Pillars, Piers, Abutments, Posts and Struts. 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 7 Thermo-Mechanically Treated bars of grade Fe-500D or more. 8 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). 9 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 10 Arranging Structural Drawing of Base ofRoof top Towerof 15 mtr height as well as Stuctural suitability/stabilitycertificatefromReputedregistered Structural Designer/consultantand supplying in A3 size intriplicateto Engineer In Charge for approval.Structural Drawing shall indicate the /column arrangement , sizes of members , reinforcement detailing etc complete. 11 Fabricating and Supplying at site hot dipped galvanized steel tower materials with average mass of zinc coating of 610 gram per Sqm (Approximately 85 micron thickness) consisting of angles, flats, tubes, bars, base plates, gusset plates, ladders, connecting plates etc. all fabricated as per specifications and drawings for erection of towers including making necessary holes for fixing nut bolts as per required drawing for mobile tower . All sections are marked with appropriate Mark Number etc. complete as directed by Engr-in- Charge. 12 Supplying of hot dip galvanised bolts and nuts of grade 4.6/5.6 and as per Is- 12427 including spring washers/plain washers of required diameters and length for mobile tower erection etc.complete as directed by Engr-in- Charge. 13 Hoisting, fixingand erection of 15 meter high RTT weighing upto 2.50 MT on the terrace of bldg upto 5 stories as per approved drawing and design with all its necessary components which include antenna fixtures, carrier and fastenings, gantry, cable feeder rack, resting and working platforms with hand rails, wave guide rack, wave guide rack support, ladders etc.,climbing ladder, platform with railing and fixing withgalvanized bolts, nuts , spring washers, necessary welding,and sorting of material at store etc wherever requiredcompletein all respect as perthe directions of the Engineer-in-charge.(Note: Rate includes cost of all operations involved in hoisting and erection of tower including hire and labour charges of tools, plants and machineries, insurance premium of labours, etc and nothing extra will be paid on any account. The contractor has to supply insurance coverage certificate of workers.) ( The item will be paid after successful completion of A/T bythe BSNL competent authority. A/T equipmentslikes Binoculars, Torque wrench of all sizes, Theodolite, shall bearranged bythe Agency) 14 Note:- The rate includes the cost of alllabours and equipmentsrequired for all the operations as described above including the cost incurred on safetybelts, helmets, first aid facilityand insurance premium ofthe labourers/ third party, the contractor has to supply insurance coverage certificate of workers, AT etc complete and watch & ward arrangement. Nothing extra will be paid on any account and complete responsibility rests on work executing Agency. Payment of only structural members, nuts & bolts shall be paid seperately. 15 a) 15 Metre Roof Top Tower 16 Providing and applying High Gloss Synthetic Enamel paint (Asian Apcolite / Shalimar/ Berger) in two or more coat on New work (including applying priming coat of ready mixed zinc chromate yellow primer and catalyst of approved brand and manufacture in required ratio) on steel galvanised iron/steel tower of required height mentioned below including painting to all the members such as platform, bracing, ties, strut, wave guide, antenna and it’s fixtures, lugs, gusset plate, angle, bolts etc. completeincluding scraaping putty, zinc chromate yellow primer & making necessary arrangements of safety-belts,helmets to labours and insurance cover etc. complete as directed by the Engineer-In-Charge. (Nothing extra shall be paid on any account) 17 15 Metre high RTT :- (a) Two or more coats over an under coat of zinc chromate yellow primer of approved brand and manufacture for 15meter RTT (any make & any weight) 18 Providing & fixing lightening arrester of multipronged finial 25mm dia 1.5m long hollow copper tube to 15 m tower with necessary fittings at the top of tower etc. all complete as per direction of Engineer-in-charge. 19 Providing & fixing G. I. flat of required size (50mm X 5mm) from lightening arrestor to the earthing including cutting and fixing on surface of tower, on tower tray, in pipe from test joint to lightening arrestor installed at top of roof top tower and from test joint to ring earth strip, including connections, etc all complete as per the direction of Engineer-in-charge 20 Supply / installation, Testing and commissioning of 230 V AC LED aviation obstruction lamp of approved quality with Light Dependent Resistance Sensor (Day-Night automatic timer) on the top of 15 m tower including making necessary arrangement for fixing with supply & fixing of base plate & required clamps, etc. as required as per the direction of the Engineer-in-charge. 21 Providing and laying of 2C X 1.5 sq. mm. PVC insulated PVC sheathed copper conductor armoured cable ISI mark from aviation lamp to existing MCB in feeder panel fixing on tower / wall / shelter surface with suitable clamp or in 25mm dia 2mm thick PVC pipe underground at 60cm depth including end termination with brass compression gland and lugs etc as per the direction of the Engineer-in-charge. 22 Providing chemical rebarring of12 mm diareinforcement bars (Drilling Diameter 16 mm) of minimum 300 mm embedment depth in RCC members with using HILTI makeRE 500V4 chemical , complete all as directed by Engineer-In-Charge. ( Note: Cost includes all labours, material T&P etc needed for the operation, Nothing extra shall be paid on any account) 23 Providing chemical rebarring of16 mm diareinforcement bars (Drilling dia 20 mm) of minimum 300 mm embedment depth in RCC members with using HILTI makeRE 500V4 chemical, complete all as directed by Engineer-In-Charge. ( Note: Cost includes all labours, material T&P etc needed for the operation, Nothing extra shall be paid on any account) 24 Fixing in positiontrue to the line and level allanchor bolts,base plates, templates and base anglesto keep the the anchor bolts as per approved drawing and as per the direction of Engineer in Charge. 25 Dismantling of dowel columnsincluding disposal of unserviceable dismantled materials and welding of reinforcement of required length for sufficient lap lengthin existing dowel columns reinforcement etc. complete as directed by Engineer in Charge. (Reinforcement shall be paid separately) 26 Sorting out of specified15/21 mtr tower materials out of materials kept randomally in BSNL storeand stacking in chronological order etc. complete as directed by Engineer in Charge. 27 Transportation of15 mtr tower materialupto 2.50 Metric tonof G.I. Structural steel menbers, it comprising of GI angles , channels, tubes, welded lugs, plates, anchor bolts, templates, ladders, nuts and bolts from BSNL store Nagpur to work site or at BSNL Store Amravati including loading, taking to weigh brigde for weighing , taking to site, unloading and stacking the material at Roof Top i.e. work siteetc completeas directed by the Engineer in charge. 28 Providing Ring earthing of tower as per drawing, specification etc. complete with labour and material of standard gauge by making pit @ 1.0 m from building/Cwall & 1.0 m depth using G.I flat of size 50x 5 mm covered alround with mixture of common salt and charcoal at a depth of 1 m in ground and connecting to two bolts of each leg of tower / pit earthing GI Electrode plate with G.I. flat including Acceptance & Testing as per direction of Engineer-In-Charge. (A/T equipments, Earth metre shall be arranged by the Agency ) (The item will be paid after successful completion of A/T by the BSNL authority. 29 Extra for using 1:1:2 (1 Cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) instead of (1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for reinforcedconcrete work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.16 Crore
Boards / Undertakings / PSU No of Bidders 1
Maharashtra View Result →
40.
Communications and Information Technology  #9127314 Technical Bid
Tender For Dismantling And Dismembering Of 40 M High Gbt Uso Tower At Bhadla And Erection The Same Tower At Manwar Site , Distt. Jodhpur Rajasthan. Sub Head- Erection Of Tower ) ; 1 Supply Of Deficient Structural Steel Galvanized Iron Tower Material, Nuts And Boltsat Site Etc. Including Making Holes Wherever Required As Per Site Requirement And As Per The Direction Of Engineer-In-Charge. 2 Labour Charges For Erection Of Ground Based Self Supporting Tower ( Of Any Height ) Using New / Old / Recovered / Dismantled Tower Material As Available At Site. The Work Shall Include The Following. 3 Erection Of Tower Including Sorting, Assembling, Lifting, Fitting And Fixing Up All Tower Members In Position True To The Alignment Including Assembling / Hoisting / Fixing Of Ladder, Working Paltform, Wave Guide Rack, Lightening Arrestor, Lightening Arrestor Pipe Stand Etc. At Required Level All Complete As Per ManufacturerS Drawing And As Per Direction Of Engineer-In-Charge. The Item Includes Enlarging Holes, Straightening Of Twisted Or Bend Tower Members Of Any Type Etc. And All Other Connected Works For The Above Operation ( If Any And As Required ) All Complete As Per The Direction Of Engineer-In-Charge. ( This Operation Is Only For Labour Charges For Erection Of Tower And Approximate Weight Of Tower Is Approximate9 To 10 Tonne. ) Notes : ( 1 ) The Items Includes For The Following And Nothing Extra Shall Be Paid On This Account. ( A ) The Agency Shall Take Every Precautions Against The Damages To The Structure Or Nearby Structures While Erecting The Tower. ( B ) Necessary Safety Precaution To Protect The Human Lives, Insurance Coverage To The Sole Responsibility Of The Agency. ( C ) Item Includes For All Operations, Tools And Plants, Equipments, Machinary Etc. Required For The Work As Well As Safety Measures As Per The Relevant Is Codes.. ( 2 ) The Items Does Not Include For The Dome Lights And Its System And Earthing System For Tower. These Shall Be Paid Under Separate Items, If And As Required. ( 3 ) The Items Does Not Include The Supply Of Tower Material / Dismantling Of Old Tower And Its Transportation. These Shall Be Paid Under Separate Items, If And As Required. 4 Providingparts Of Aviation Light As Necessary So As To Satisfy Aviation Requirements. 5 Supplying, Installing, Testing & Comissioning Ofsingle Dome Aviation Obstruction Light ( Aol ) Fixture Having Base Made Of Aluminium Die Cast / Fibre Body And Top Cover Of Red Polycarbonate Dome & 230V Ac Led Aviation Obstruction Lamp With 300 &More Nos. Clear LedS Having Light Intensity Of Minimum 1200 Lux & Necessary Auto On-Off Scanner Photo Cell Unit With Transformer In Built In Dome Light Of Make From Vijay, Binoy, Altrox Or Equivalent Etc. With Necessary Clamps For Fixing Arrangement Etc.All Complete As Per The Direction Of Engineer- In-Charge. 6 Providing And Fixingmcbof Range 6-32 Amp Of Havells, Merlin Gerin Or Equivalent Make. 7 Providing And Fixing Pvc Double Insulated 2 Corex1.5 Sqm. Copper Conducter / Unarmoured Power Cable ( Finolax, Polycab Or Equivalent ) Including Removing Damaged Power Cable And Encasing New Power Cable In Existing Pvc Conduit Pipe. 8 Providing And Fixing Pvc Conduit Pipe Of 20 Mm Dia Of Approved Brand And Manufacture All Complete As Per Direction Of Engineer- In-Charge.The Rate Includes For All Themeterials, Labour And T&P Etc Required Forall Theworks As Mentioned Above. 9 Earthing With Galvanised ( Approximate 85Micron ) Gi Plate Of 600X600x6mm Size As Directedincluding Accessories And Providing Necessary Havinglocking Enclosurs With Cover Plates Arrangementand Watering Pipe 20Mm Dia G.I Pipe Etc. Includingfilling Charcoal Or Coke@ 50Kg Per Pit And Salt @ 5Kg Per Pit Complete As Required And As Directed By The Engineer-In-Charge. 10 Providing Ring Earth By Running Gi Flat Of Size 50X6mm Alround At 1.00 Metre Away From The Tower Base In Ground At A Depth Of One Metre From Ground Level. All Tower Legs Shall Be Connected To Ring Earth By 50X6mm Gi Flat With Necessary Accessories Etc. Both Ends Of The Gi Flat Shall Be Brought To Ground Level And Terminated In An Enclosed Brick Masonry Chamber Of Inside Size 300X300x300mm With 35 Class Designation Bricks In Cement Mortar 1:6 ( 1Cement: 6 Coarse Sand ) Including Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand:10 Graded Stone Aggregate 40Mm Nominal Size ) Plastering With 12Mm Cement Plaster 1:3 ( 1 Cement: 3 Fine Sand ) With Hinges Ci Cover And Frame Of 300X300mm ( Weight Of Cover Not Less Than 4.5 Kg ) With Proper Locking Arrangement Complete All As Directed By Engineer-In-Charge. 11 Painting With Luxol High Gloss Synthetic Enamel Paint With Two Or More Coats Ofrequired Shade And Colour To Give An Even Shade As Per Aviation Requirements Etc. All Complete As Per The Direction Of Engineer-In -Charge. ( The Agency Shall Arrange For All The Material , Labour, T &P Etc. Required For The Work. 12 40 M Ground Basetower 13 Carriage And Transport Of Dismantled 40M Nblw / Uso Tower Materials, Runway, G.I.Strips, Fencing Materials Including Chain Link Fencing Roll , Angle Iron Posts, G.I.Flats, Nuts & Bolts , Steel Gatesetc. All Complete Materials From Barmer Bsnl Storeto Manwar Site , Jodhpur ( Approximate Distance 198 Kms ) Including Loading, Unloading, Stacking Etc. All Complete As Per Direction Of Engineer-In-Charge. 14 Sorting Of 40M ( Gbt ) Usotower Material At Bsnl Store Barmeretc. All Complete As Per Direction Of Engineer-In-Charge. 15 Notes : 16 ( 1 ) Necessary Safety Precautions To Protect The Human Lives, Insurance-Coverage Etc.Shall Be The Sole Responsibility Of The Agency. ( 2 ) All The Safety Measures Shall Be Taken By The Agency As Per The Relevant Is Codes. ( 3 ) The Painting Shall Be Done Carefully So That All The Corners And Crevices Of The Tower Receive The Paint. ( 4 ) No Driers Such As Litharge Or Turpentine Are To Be Used.The Practice Of Mixing Kerosene-Oil With Paint Is Strictly For Bidden.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
41.
Housing Urban and Rular Development #9084402 Technical Bid
Tender For Highmast Light And 6 Nos Road Light (E/W) In Construction Of Various Develpments Works At Gurudwara Budha Johad Distt Sri Ganganagar (Ew) Highmast Light And 6 Nos Road Light(E/W) In Construction Of Various Develpments Works At Gurudwara Budha Johad Distt Ri Ganganagar (Ew), 1 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 2 Poles with Octagonal Cross Section 3 7 Mtr. 4 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 5 Single arm overhang 6 Double arm overhang 7 Providing and Laying RCC Foundation for Octagonal/ Conical Street Light poles, High mast Poles as per Drawing attach at TableP-4with Following Procedure& All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 A) Excavation of Pit for Foundation Size upto required depth from Ground level 9 B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 10 C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness 11 D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. 12 E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal 13 F) Providing & Fixing of 2 no. Required SizePLB HDPE Pipe& Foundation Bolt with template as per OEM Recommendations. 14 G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. 15 H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. 16 Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 17 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 18 25.0 Sq. mm 19 3.5 core 20 6.0 Sq. mm 21 4 core 22 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 4 pole MCCB With Thermal Magnetic release 24 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 25 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 26 3x 1.5 sq.mm 27 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 28 Red/yellow/Green colour 29 Blue / white Colour 30 Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 31 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 3 pole Power contactorswith following AC 3 Rating 33 40 Amp 34 Providing & Fixing ofthermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 24 to 40 Amp 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 37 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 38 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 39 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 40 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 41 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 42 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 43 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 44 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 46 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 47 25mm x 3mm G.I. ( Hot Dipped) Strip 48 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 49 10 SWG G.I. ( Hot Dipped) Wire 50 Supply installation testing & Commissioning ofhigh mast lighting system (as per PLG 07of ILP UKtechinical report no7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstructionlights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation.(See table P - 03 for specs.) OEM Must haveType test certificate for wind tunnel test .All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 20.0 Mtr Hm (in 2 section) suitable for 12 No. Luminaries 52 Providing & Fixing ofIK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles,of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K±355K.Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 High Power LED Flood Light Minimum lumen output 37500 lm 54 High Power LED Flood Light Minimum lumen output 18650 lm 55 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 56 LED Street Light fixture with Minimum lumen output 11225 lm 57 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 58 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 59 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 60 Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 61 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 62 Triple pole MCB(With B/C curve trippingCharacteristics) 63 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
43.
Power #8854938 Technical Bid
Procurement Of Safety And Security Equipment For Asan Barrage , Dhalipur , Safety And Security Equipment , Hand Held Metal Detector , Detectable Material: Ferrous And Non Ferrous Metals , Wooden Substructures , Live And Non Live Cables , Detection Depth: 12 Centimeters , Automatic Deactivation: 5 Minutes , Capacitive , Inductive And 50 Hertz Sensors With Zoom Function For Accurate Locating Of Material Inside The Wall , Complete With Rechargeable Batteries , Pouch , Hand Strap , Make: Bosch / Bounty Hunter / Fisher , Door Frame Metal Detector , Outdoor Type , 18 Zone Walkthrough With Traffic Counter And Battery Backup Make: Bosch / Bounty Hunter / Fisher , Caution Tape Reflective Type With Sharp Colour Contrast , Yellow Tape With High Visible Bold Black Font , Made Of Quality Pe Material , Non Adhesive Tape , Resistant To Fading , Tearing , Bad Weather And Waterproof , Thick And Durable , Size 75Mm X 200M X 0 . 03Mm Make: Darit / Ladwa / 3M , Led Search Light 20W ( Range 2 Km . ) With Upto 10000 Mah Lithium Battery - Multi-Functional Torch , Make: Havells / Wipro / Bajaj / Emerald , Safety Tube Free Size Have An Outer Diameter Of Not More Than 800 Mm And An Inner Diameter Of At Least 400 Mm , Made Of Non-Fading Material , Be Constructed Of Inherently Buoyant Material , Fitted With A Grabline Not Less Than 9 . 5 Mm In Diameter & Length 20 Meter , Solas Approved , Life Jacket Free Size With Adjustable Strap , Retro Reflective , Solas Approved , Safety Reflective Vest For Outdoor Use , Elastic , Lightweight , Adjustable Strap , 360 High Visibility From 250 Meter On All Weather Conditions: Night , Fog , Rain , Dark , Dusk , Made Of High-Grade Nylon Elastic Belt & High-Lighting Reflective Cloth , Light Weight , Comfortable , Make: 3M / Lifekraft / Darit / Gaurav , Safety Helmets With Ratchet Type Adjustable Strip , White Colour , Make Dokfin / Wuerth / 3M / Karam / Rocksport , Safety Helmets With Ratchet Type Adjustable Strip , Blue Colour , Make Dokfin / Wuerth / 3M / Karam / Rocksport , Safety Helmets With Ratchet Type Adjustable Strip , Yellow Colour , Make Dokfin / Wuerth / 3M / Karam / Rocksport , Safety Helmets With Ratchet Type Adjustable Strip , Brown Colour , Make Dokfin / Wuerth / 3M / Karam / Rocksport , Safety Helmets With Ratchet Type Adjustable Strip , Grey Colour , Make Dokfin / Wuerth / 3M / Karam / Rocksport , Safety Harness Half Body Complete With All Accessories , Make: Karam / 3M / Allen Cooper , Safety Harness Full Body Complete With All Accessories , Make: Karam / 3M / Allen Cooper , Stretcher Double Fold , Washable , Water Proof & Anti-Fungus Fabric Top With Safety Belts , With Carry Bag , Load Bearing Capacity 160 Kg , Make: Kosmocare / Standard Health Care / Khl , Led Traffic Baton Red / Green Size:- 520Mmx30mm , Battery Operated , Make: Ladwa / Pioneer / Rks , Convex Mirrors Size:- 600Mm , For Outdoor Use , Environment Resistant , Fitted With Sunshield Or Protective Hood Complete With Fixing Arrangement , Make Frontier / Dua / Ladwa / Pioneer , First Aid Kit Box Mounting Type With Accessories I . E General Medicines , Cotton Gauze , Antiseptic Lotion , Povidine Lotion & Cotton , Make Thadani / Jilichem / St . Johns , Retro-Reflective Barricade ( Made Of Pvc , Water Filled With Interlocking Feature ) Size 36 X 72 X 24 , Make: Frontier / Bdi / Neelkamal / Supreme , Traffic Cone 750Mm , Base 300 X 300 Mm , With Chain And Hooks , Make: Frontier / Bdi / Neelkamal / Supreme , Binocular Optical Zoom 10X , Eye Relief 14-16Mm , Dioptric Correction +3 / -3 , Objective Lens Diameter > 40Mm , Nitrogen-Filled Body For Waterproof / Fogproof / Dirtproof Performance , Make Nikon / Carl Zeiss / Vortex , Kernmantle Rope Size 12 Mm ( 50 Meter Length ) , Make Karam / 3M / Heapro , Polyamide Rope 20 Mm ( Length 30 Meter ) , Make Karam / 3M / Heapro , Rubber Hand Gloves Reusable Type Made Of Latex Rubber , Slip Resistant Texturing Cover Palm And Finger , Abrasion And Puncture Resistant , Karam / Frabble / Ss& Ww / Kanvee Rubber , Mega Phone 20 Watts ( 30 Watts Max . ) Shoulder Sling Strap / Pistol Grip Hand Held , Voice Range: 500 Meter ( 1000 Meters In Quite Area ) , Switchable Siren / Usb Function And Aux Input , Rechargable Battery Operated , Make Pyle / Ahuja / Speco Technologies , Wheeled Waste Bin With Pedal Opening 60 Ltr Capacity ( 1 No . Yellow , 1 No . Blue And 1 No . Green Colour =1 Set ) , Make: Sintex / Nilkamal / Aristo / Fiable / Supreme , Aviation Obstruction Led Light ( Double ) , Heavy Duty , Ip 65 , With Photo Cell Switch Make: Lumax / Kheraj / Bajaj / Kalin
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttarakhand View Result →
44.
Communications and Information Technology  #8835960 Technical Bid
Tender For Gsm Bts Equipment Accessories And Passive Infra Equipment Lifting Handling Loading Unloading Including Transportation From Point To Point And En Route And Removal Of Tower Dg Shelter And Their Foundations Under Gm Cm In Htd . , Transportation Telecom Stores , Transportation Telecom Stores Such As Bts Equipments , Batteries , Power Plants , Rf Cables , Dmw/Ofc Equipments , Antenna , And Other Allied Accessories/Equipment By Motor Transport Vehicles From Any Point To Any Point In Hyderabad Telecom District Comprising Twin Cities Of Hyderabad And Ranga Reddy District Including Lifting , Handling , Loading , Unloading At Both Ends . ( Along With Weigh-Ment Octroi , Tollgate Charges , Etc . , ) ( Rate Per Quintal Per Kilometer To Be Quoted ) ( Approximate Quantity: 26675 Quintal Kms ) . , Dismantling Of Roof Top Structural Steel Tower/ Marr Mast Of 9/12/15/18/21 Mtrs Height ( Approximately ) And Cable Gantry With All Necessary Components Viz . Climbing Ladder , Platforms With Railing , Bolts , Nuts , Washers Etc . Including All Complete Operations Involved In Dismantling , Lifting And To Be Transported & Stacked Properly At Warehouse . ( Note: Per Site Consists Of Maximum Of 3 Poles/Marrmasts/Towers ) . ( Rate Per Site To Be Quoted ) ( Approximate Quantity: 15 Sites ) . , Dismantling Of Bts Shelter Of Size 3 . 13*2 . 13*2 . 75 Mtrs , Including Dismembering Frames / Panels , Doors Shutter Including Connecting Clamps , Cable Trays , Flanges , Nuts , Bolts Washers , Rivets And Other Fittings Etc . , And Lifting All The Dismantled Materials From Roof Top ( Terrace ) To Ground Floor And To Be Transported & Stacked Properly At Warehouse . ( Note: Per Site Consists Of Maximum Of 1 Shelter ) . ( Rate Per Site To Be Quoted ) ( Approximate Quantity: 15 Sites ) . , Removal Of Diesel Generator Set ( Canopy Type ) , Including Dismantling Of Electrical Items ( If Available ) Ac Power Cable , Earthing Strip , Aviation Lamp / Lighting Arrestor , Acdb , If Any , And Stacking All The Material At Ground Floor By Means Of Hydraulic Crane/Manual Labour As Per Site Conditions And Transporting Them To Warehouse Lead By Mechanical Means , Unloading All The Items By Means Of Hydraulic Crane/Manually . ( Note: Per Site Consists Of Maximum Of 1 Dg Set ) . ( Rate Per Site To Be Quoted ) ( Approximate Quantity: 15 Sites ) . , Demolishing The Foundations Of Removed Poles / Marr Mast / Rtt / Shelter / Dg Set Consisting Of Rcc / Building Rubbish / Melba / Similar Unserviceable , Dismantled Or Waste Materials By Mechanical Means Including Loading , Transporting , Unloading To Approved Municipal Dumping Ground . Work Also Involves Plastering & Patch Up Of Demolished Area With Cement . ( Rate Per Site To Be Quoted ) ( Approximate Quantity: 15 Sites ) .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
45.
Public Administrative Department #8822685 Technical Bid
Supply Of Machine Tools Equipment For Gola Centre-1 Leather Hand Gloves 14” 2 Cotton Hand Gloves 8” 3 Leather Apron 4 S.S Wire Brush 5 Leather Hand Sleeves 6 Safety Boots For Welders 7 Leg Guards Leather 8 Rubber Hose Clips 9 Rubber Hose Oxygen 10 Rubber Hose Acetylene 11 Arc Welding Cables 12 Arc Welding Single Coloured Glasses 13 Arc Welding Plain Glass 14 Gas Welding Goggles 15 Safety Goggles Plain 16 Spark Lighter 17 Ag 4 Grinding Wheels 18 Welding Helmet Fiber 19 Welding Hand Shield Fiber 20 Chipping Hammer With Metal Handle 21 Chisel Cold Flat 22 Centre Punch 23 Dividers 24 Stainless Steel Rule 25 Scriber 26 Flat Tongs 27 Hack Saw Frame Fixed 28 File Half Round 29 File Flat 30 Hammer Ball Pein 31 Welding Torch Tip Cleaner 32 Try Square 33 Spindle Key 34 Screw Driver 35 Number Punch 36 Letter Punch 6 Mm 37 Magnifying Glass 38 Universal Weld Measuring Gauge 39 Earth Clamp 40 Spanner D.E. 41 C-Clamps 42 Hammer Sledge Double Faced 43 S.S Tape 44 Electrode Holder 45 High Pressure Welding Torch With 5 Nozzles 46 Oxygen Gas Pressure Regulator Double Stage 47 Acetylene Gas Pressure Regulator Double Stage 48 Co2 Gas Pressure Regulator, With Flow Meter 49 Argon Gas Pressure Regulator With Flow Meter 50 Metal Rack 182 Cm X 152 Cm X 45 Cm 51 First Aid Box 52 Steel Lockers With 8 Pigeon Holes 53 Steel Almirah / Cupboard 54 Black Board And Easel With Stand 55 Flash Back Arrester ( Torch Mounted ) 56 Flash Back Arrester ( Cylinder Mounted ) 57 Welding Transformer With All Accessories 58 Welding Transformer ( Or ) Inverter Based Welding Machine With All Accessories 59 D.C Arc Welding Rectifiers Set With All Accessories 60 Gmaw Welding Machine 61 Ac / Dc Gtaw Welding Machine 62 Air Plasma Cutting Equipment With All Accessories 63 Air Compressor Suitable 64 Auto Darkening Welding Helmet 65 Spot Welding Machine To 15 Kva With All Accessories 66 Portable Gas Cutting Machine Capable Of Cutting Straight & Circular With All Accessories 67 Pedestal Grinder Fitted With Coarse And Medium Grain Size Grinding Wheels Dia. 300 Mm 68 Bench Grinder Fitted With Fine Grain Size Silicon Carbide Green Grinding Wheel Dia. 150 Mm 69 Ag 4 Grinder 70 Suitable Gas Welding Table With Fire Bricks 71 Suitable Arc Welding Table With Positioner 72 Trolley For Cylinder ( H.P. Unit ) 73 Hand Shearing Machine 74 Power Saw Machine 14’’ 75 Portable Drilling Machine ( Cap. 6 Mm ) 76 Oven, Electrode Drying 77 Work Bench 78 Bench Vices 79 Oxy Acetylene Gas Cutting Blow Pipe 80 Oxygen, Acetylene Cylinders 81 Co2 Cylinder 82 Argon Gas Cylinder 83 Anvil 12 Sq. Inches Working Area With Stand 84 Swage Block 85 Die Penetrant Testing Kit 86 Magnetic Particle Testing Kit 87 Fire Extinguishers ( Foam Type And Co2 Type ) 88 Fire Buckets With Stand 89 Portable Abrasive Cut-Off Machine ( Small ) 90 Suitable Gas Cutting Table 91 Welding Simulators For Smaw / Gtaw / Gmaw / 1 Steel Rule With Metric & British Graduation 2 Try Square. 3 Caliper Inside Spring Type. 4 Caliper Hermaphrodite Spring Type 5 Caliper Outside Spring Type 6 Divider Spring Type 7 Scriber 8 Centre Punch 10 Mm And Length - 120 Mm. 9 Screw Driver 10 Chisel Cold Flat 11 Hammer Ball Pein With Handle 12 Hammer Ball Pein With Handle. 13 File Flat 14 File Flat 15 File Half Round 16 Hacksaw Frame 17 Safety Goggles. 18 Dot Punch 19 Steel Rule Graduated Both In Metric And English Unit 20 Straight Edge Steel 21 Spirit Level Metal Type - 2 22 Stud Extractor Ezy - Out 23 Combination Set 24 Micrometer Outside. 25 Micrometer Outside. 26 Micrometer Outside. 27 Micrometer Inside With Extension Rods. 28 Vernier Caliper 29 Vernier Height Gauges 30 Vernier Bevel Protractor Blade With Acute Angle Attachment 31 Screw Pitch Gauge Metric 32 Wire Gauge, Metric Standard. 33 Surface Plate 34 Marking Table 35 Universal Scribing Block. 36 V-Block Pair With Clamps 37 Angle Plate 38 Punch Letter Set. 39 Punch Number Set. 40 Portable Hand Drill ( Electric ) 41 Drill Twist Straight Shank 42 Drill Twist Taper Shank 43 Taps And Dies Complete Set In Box. Wit-Worth 44 Taps And Dies 45 File Knife Edge 46 File Feather Edge 47 File Triangular 48 File Round 49 File Square 50 Feeler Gauge 51 File Triangular 52 File Flat 53 File Flat 54 File Flat 55 File Swiss Type Needle 56 File Half Round 57 File Half Round 58 File Round 59 File Hand 60 File Card. 61 Oil Can 62 Pliers Combination Insulated 63 Wooden Handle Forged Soldering Iron 64 Blow Lamp ( Brass Body ) 65 Spanner- Double Ended 66 Spanner Adjustable 67 Interchangeable Ratchet Socket Set 68 Double Ended Tubular Box Spanner Set 69 Glass Magnifying 70 Clamp Toolmaker 71 Clamp C 72 Clamp C 73 Hand Reamer Set ( Taper Pin Straight Flute ) 74 Machine Reamer Parallel Shank ( Helical Flute ) 75 Scraper Flat 76 Scraper Triangular 77 Scraper Half Round 78 Chisel Cold Cross Cut & Diamond Point. 79 Chisel Cold Flat 80 Chisel Cold Round Noze. 81 Drill Chuck With Key 82 Pipe Wrench 83 Pipe Vice 84 Adjustable Pipe Die Set Bsp 85 Wheel Dresser 86 Machine Vice - Swivel Base 87 Machine Vice - Swivel Base 88 Sleeve Drill 89 Vice Bench 90 Bench Working. 91 Almirah ( Without Locker ) 92 Lockers With 8 Drawers 93 Metal Rack 94 Instructor Table 95 Instructor Chair 96 Black Board With Easel. 97 Fire Extinguisher 98 Fire Buckets. 99 Machine Vice. 100 Wing Compass. 101 Hand Hammer With Handle. 102 Torque Wrench ( Standard / Ratchet Type ) 103 Power Tools For Fastening 104 Different Profile Gauges ( Plate Type ) 105 Knurling Tool 106 Indexable Boring Bar With Inserts 107 Machine Maintenance Mannual For Lathe, Pedestal Grinder, Drill Machine, Power Saw 108 Temperature Gauge 109 Dowel Pin ( Straight ) 110 Standard Tap Screws 111 Lapping Plate 112 Drill Gauges 113 Cast Iron Globe Valve ( Flanged Type ) 114 C.I. Sluice / Gate Valve ( Flanged Type ) 115 Stop Cock 116 Slip- On Forged Steel Flange 117 Pipe Threading Die With Handle Ratchet Type 118 Pulleys 119 V-Belt And Flat Belt ( To Fit On Pulley ) 120 Packing Gasket ( Ptfe Gasket Roll Small Size ) 121 Washer, Clutch, Keys, Jib, Cotter & Circlip 122 Hollow Punch 123 Bearings Different Types ( Ball & Roller ) 124 Lifting Sling 125 Bearing Extractor 126 Pulley Extractor 127 Trammel 128 Pocker. 129 Prick Punch 130 Mallet. 131 Aviation Snips Straight Cut 132 Flat Headed Hammers With Handle. 133 Planishing Hammer. 134 Snip Bent Left Cut 135 Stake Hatchet With Leg. 136 Stake Grooving. 137 Slip Gauge As Johnson 138 Gauge Snap Go And Not Go 139 Gauge Plug 140 Gauge Telescopic Set. 141 Dial Test Indicator On Stand 142 Sine Bar 143 Dial Vernier Caliper. ( Universal Type ) 144 Screw Thread Micrometer With Interchangeable. Pitch Anvils For Checking Metric Thread 60. 145 Depth Micrometer. 146 Vernier Caliper. 147 Digital Micrometer Outside. 148 Comparators Gauge - Dial Indication With Stand And Bracket. 149 Engineers Try Square ( Knife-Edge ) 150 Surface Roughness Comparison Plates 151 Digital Vernier Caliper 152 Vernier Bevel Protector 153 Carbide Wear Block. 154 Lathe Tools H.S.S. Tipped Set. 155 Lathe Tools Bit. 156 Lathe Tools Bit. 157 Lathe Tools Bit. 158 Arm Strong Type Tool Bit Holder. ( Right Hand ) 159 Arm Strong Type Tool Bit Holder. ( Left Hand ) 160 Arm Strong Type Tool Bit Holder. ( Straight ) 161 Stillson Wrenches 162 Pipe Cutter Wheel Type. 163 Pipe Bender Machine Spool Type With Stand Manually Operated 164 Adjustable Pipe Chain Tonge To Take Pipes 165 Adjustable Spanner. 1 Ss And Sc Centre Lathe ( All Geared ) With Minimum Specification. 2 Pillar Type Drilling Machine 3 Drilling Machine Bench 4 D.E. Pedestal Grinding Machine With Wheels Rough And Smooth 5 Compressor Unit 6 Pneumatic Kit 7 Carrier For Mounting Components, Such As Pb & Relay Boxes. 8 Cut Section Model For Pneumatic Components 9 Hydraulic Kit 10 Cut-Section Models For Hydraulic Components
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
46.
Educational and Research Institute #8792520 Technical Bid
Short Term Tender Notice For Tools And Equipment For Early Identification And Intervention Center - 1 Laminated Flash Cards / Picture Cards Of All Categories ( Body Parts, Fruits, Vegetable, Animal, Vehicles, Birds, Food Items Clothes, Kitchen Items, General Items ) 2 Squeezers / Noise Makers & Dumroo 3 Wooden Rattle 4 Story Cards 5 Laminated Flash Cards Of Opposites & Singular Plural 6 Puppets 7 Story Books ( Panchatantra ) 8 Torch Light 9 Ice Cream Sticks Packs 10 Sterilizers 11 Mirror 12 Straws Different Sizethick Shape Straws 13 Hand Sanitizer 14 Hand Tissues 15 Mattress 6 Feet X 3 Feet 16 Noise Making Toys ( Bell, Drum, Kanjeera, Jingles, Squeakers Toys ) Cordless Handril Handril With Wire With Accessories For Stone Rotary Jig Saw Machine Jig Saw Blade 4 Leather Cutting Scissors Heavy Duty With Brass Handle 12Inches 5 Screw Driver Set 5 Heat Gun, 2000 Watts 6 Hammer Ball Pin, 500 Gms, 105Mm 7 Leather Puch Revolving, Hole Plier 8 Allen Key Set, Taparia, 9 Bench, Grinding Machine, 10 Plier, Steel 11 Mallet Soft Hammer Diameter: 57Mm Weight: 450Gms. 12 Aviation Tin Cutter 13 Steel Snap Off Cutter 14 Anvil Bench 15 Bench Vise 6” / 150M 16 Surfoam File Blade 17 Scalpel Blade. No.11. Ss, Pack Of 100 18 Hack Saw , With Blade 19 Mac Master Torque Wrench, 5-35Nm 20 Steel Scale, 24” 21 Debring Tool With Blades ( 10 Pcs ) 22 Bending Apparatus 23 Goniometer Steel 24 Weighing Machine 25 Bandage Scissor 26 Steelwater Bowl For Casting 27 Horizontal Galvanized Metal Pegboard Tool Board Panel 28 Peg Board Plastic Bin 29 Peg Board Steel Hooks , Variety 30 Patient Assessment Couch, Examina Tion Couch With Cabinet &Drawers 31 Child , Height Mesuringwall Sticker 32 Work Bench Table 1 Wall Stickers : Alphabets ( Capital ) 2 Wall Stickers : Alphabets ( Small ) 3 Wall Stickers : Numbers 4 Wall Stickers : Shapes, Colors, Vegetable, Fruits, Animals Etc. 5 Body Part Puzzels And Shape Puzzel 6 Vegetable & Fruits Model 7 English Alphabet Tray- Upper Case & Lower Case 8 Number Tray 9 Shapes Board 10 Build A Tower : Big Circle 11 Build A Tower : Stacking Cubes 12 Animal, Fruits, Vegetable And Vehicle Puzzels 13 Number Flash Cards 14 English Alphabet Flash Cards 15 Wooden Beeds – Big, Medium And Small With String / Wire 16 Adl Frame Button Push Button Zip And Velcro 17 Lacing Frame 18 Animal Toys 19 Crayons 20 Water Colour 21 Charts And Pastel 22 Pencil 23 Eraser 24 Sharpener 25 Clock 26 Digital Calendar 27 Slide 28 Tunnel 29 Doll House 30 Colourful Balls – Big Medium And Small 31 Body Part Toys 32 Clay
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
47.
Housing Urban and Rular Development #8667568 AOC
Tender for Atal Bus Stand (C Type) At Rampur Under M.Rampur Block, Kalahandi.-- 1 CVL 2 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 3 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 4 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 5 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 6 First Floor 7 Second Floor 8 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 9 First Floor 10 Second Floor 11 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 12 First Floor 13 Second Floor 14 50000044 Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ). Ground Floor 15 50000057 Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height. Ground Floor 16 First Floor 17 50000076 Plinth protection with side brick masonry wall (1:4) inside sand filling over which 100 mm thick cement concrete using 40 mm coarse aggregate in prop (1:3:6) and over that, 50 mm thick cement concrete using 12mm to 19mm coarse aggregate in prop (1:2:4) with cement plastering (1:4) in proper slope. Ground Floor 18 50001152 Providing & fixing aluminium work (min.thickness of powder coating 50 micron) for structural glazing including required scaffolding for fixing the aluminium sections for extruded builtup standard tubural & other sections of approved make confirming to IS:733 and IS:1285 fixing with rawl plugs & screws or with expansion hold fasteners including necessary fillings up gaps at junctions at top,bottom & sides with cement mortar,aluminium sections shall be smooth,rust free ,straight,mitred & jointed mechanically,the glazing will be 5mm thick,coloured,reflective glass of approved colours & make (SAINT GOBAINI) fixed in aluminium sections upto required height & joints filled clear weather silicon sealant etc complete in all respect as per the direction of EIC/Architect in charge. Ground Floor 19 First Floor 20 Second Floor 21 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 22 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 23 First Floor 24 Second Floor 25 50001311 Fly Ash brick masonary in cement mortar 1:4:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 26 First Floor 27 50005074 Supplying, installing RO +UV+UF+TDS control+UV in-tank and zero water wastage technology with active cupper technology, wall mounted water purifier aquaguard capacity up to 20L/hr(Make KENT-grand star/Eureka Forbes)[N.S.W.I] Ground Floor 28 50010026 Supplying, Fitting and fixing of glass reinforced concrete(GRC) screens 30mm to 32mm thick (Dry density>1800 kg/cum) on wall (Wall cladding) and module of 1.5 sqm of approved quality/ pattern shall be synthetic rubber/ FRP moulded in size, pattern, design, colour and thickness. The screens made of 53 grade white cement make Birla/JK cement, quartz, fine silica sand, alkali resistance glass fiber, super plastisizer, polymers and UV resistant synthetic inorganic pigments etc. The screen shall be fixed by dry fixing method with appropriate SS pipe 304 grade ‘L’ shaped clamps & cleat, using fasteners and necessary hardware, etc. Including MS scaffolding in building façade. The rate shall be included the structural steel frames (Horizontal & vertical members) support to hold the GRC jalli at required building height to withstand wind pressure as per IS 875(prt-3):2015. The cost includes labour, materials, transportations, T&P, etc. all complete as per direction of Engineer-in-Charge. The screen must have compressive strength>400kg/cm2 ,wet transverse strength > 7 N/mm, thermal conductivity1.63 W/m-K at 3% moisture content, water absorption<(><<)> 5% of dry weight. [NEW-NSWI] Ground Floor 29 First Floor 30 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 31 First Floor 32 Second Floor 33 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 34 First Floor 35 Second Floor 36 50010384 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC SILL BAND) Ground Floor 37 First Floor 38 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 39 50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor 40 First Floor 41 Second Floor 42 50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor 43 First Floor 44 Second Floor 45 50010432 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC STAIRCASE) Ground Floor 46 First Floor 47 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 48 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 49 First Floor 50 Second Floor 51 50010458 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement. (FOR RCC FINS) Ground Floor 52 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 53 First Floor 54 Second Floor 55 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 56 First Floor 57 Second Floor 58 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 59 First Floor 60 Second Floor 61 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 62 First Floor 63 Second Floor 64 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 65 First Floor 66 Second Floor 67 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 68 First Floor 69 Second Floor 70 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 71 First Floor 72 Second Floor 73 50010668 Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/Green Ground Floor 74 First Floor 75 50010680 Providing and fixing of ISI marked 30 mm thick Flush door Shutters (Single leaf) finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125 mm x 85 mm x 5.5 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 1 No SS Aldrop (400mm X 300mm x 16mm dia rod), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials,adhesives etc complete. (Excluding door closure, ornamental handle and Mortise Lock). [NSWI] Make:- BWP Flush door (Century Sainik 710 / Green marine gold 710), Laminate (Greenlam/ Centurylam,Marino),Hard ware fittings (Godrej). Ground Floor 76 First Floor 77 50010704 Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej). Ground Floor 78 First Floor 79 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 80 First Floor 81 Second Floor 82 50010815 2.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete. Second Floor 83 50010827 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL. Ground Floor 84 First Floor 85 50010839 Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX. Ground Floor 86 First Floor 87 50010975 Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb). Ground Floor 88 First Floor 89 50011029 Providing and painting the mural art painting work on wall/floor/ceiling by the selected artist/ agencies to make the art most visible of the stretch. The work includes scraping and cleaning of wall, painting one primer coat and one weather seal coat (Asian/ Berger/Dulux), applying paint for mural art painting. The paint must have a durability of at least 5 years. The cost of the work includes all the labour, man power, scaffolding, transportation, materials required, fooding, etc. for execution of the mural art to give the finish product. It must be noted that, the height shall be calculated from the point where the painting starts till the point it continues and ends. UPTO 3M HEIGHT Ground Floor 90 First Floor 91 50011406 Providing and fixing of factory-made 3Track 3Panel UPVC Sliding window (White Colour) frame size 128X50mm and Sash size 45X70mm complete up to and including 1.5m high, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber. The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 5mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 5 mm clear Toughened glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep glass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN) Ground Floor 92 First Floor 93 50011416 Providing and fixing of factory-made 2Track 2Panel UPVC Sliding window/Door (White Colour) frame size 70X50mm and Sash size 45X74mm complete above 1.5m high, comprising UPVC multi-chambered frame having in-built UPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber.The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm.UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 6mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 6 mm clear Toughened glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock &Multi Lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep gl ass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN) Ground Floor 94 First Floor 95 50011456 Supplying, Fitting & Fixing of full body Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 1200mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL) Ground Floor 96 First Floor 97 50011486 Supplying, Fitting & Fixing of Anti-Skid Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 600mm x 9 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY TECHSTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL) Ground Floor 98 First Floor 99 50011496 Supplying, Fitting & Fixing of Industrial parking heavy duty Vitrified Tile (PREMIUM QUALITY) on floors of size 300mm x 300mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY DURASTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL) Ground Floor 100 50011926 Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF) Second Floor 101 50011948 Supply and installation of ZMS (Nylon)/Vibrance Serene series cubicles of width and depth as per specifications/ site drawings and height of 2000mm. The cubicle is made from solid grade 12mm thick compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C with bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers made of Alpha cellulose fiber impregnated with thermosetting melamine resin which provide superior scratch, abrasion, heat, chemical, impact, graffiti & moisture resistance along with anti-bacterial properties. Panels have a black core that when machined, presents a distinctive black edge. All doors of size 600x1800mm will be of single colour and made of 12 mm thick HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 nos Nylon PA-6 made hinges affixed to the pilasters. Nylon PA-6 made coat hook and lock set are provided with each door. All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed with stainless steel made thumb turn lock set. Aluminum made door stopper profiles with rubber linings for dampening the noise while door closing will be provided at the vertical ends of the pilasters. Pilasters will be anchored to the floor using Nylon PA-6 made adjustable legs. The bottom gap is 150 mm. All intermediate partitions or dividers of 1800mm hight will be made of 12 mm thick HPL compact laminate panels. They are affixed with aluminium made U-channel at their ends for ultimate stability of the system. The Semi-spherical (Top) head frame structure for surface protection of size to be 50x32x1.6T, Corner joinery section size to be 40x16.5x1.8T,U-Channel Wall joinery section size to be 22x16x1.6T,Door stopper section size to be 21x12.5x1.6T. Nylon Polyamide grade-6 Adjustable Pedestal Footing of base minimum diameter 70 mm, giving a clearance height of 150mm. Self closing Hinges (Gravity mechanism) made from Nylon Polyamide grade-6. Round Coat hook with base diameter 53 mm made from Nylon polyamide grade-6. Round Door knob diameter 48 mm with thumb-recess made from Nylon polyamide grade-6. Rotating Thumb-turn locking system with privacy indicator locking system made from Nylon polyamide grade-6, Anti-noise rubber padding, Stainless steel grade 304 screws, Anti-rotation Nylon polyamide grade-6 expandable wall plugs. The cost includes supply, installation, transportation, handling charges completely. Make complete set:MERINO/GREENLAM Ground Floor 102 First Floor 103 50011984 Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification. Ground Floor 104 First Floor 105 50012200 System Aluminum Casement System Doors – Double Leaf Swing single glazed door Providing and fixing System Aluminum works for casement systems door having door frame 55mmx40mm, shutter 70mmx40mm, door bottom transom 150mmx40mm, central profile 47.3x42.9mm, grazing bead 31.8mmx17.85mm with glazing of single glass panel without middle transom made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. The drainage slots provided at the bottom part of the frame/sash on the outerside & weather strip siliconased brush gasket will be provided. 6mm Clear Toughend Glass (Saint-Gobain / AIS) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. The casement systems having hardwares SS handle (22mmx300mm), mortise lock with both side key cylinder, floor spring. Wall Thickness - Aluminium: 1.5mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD) Ground Floor 106 50012828 Supply and fixing of MCM Modified Clay Material ‐ MCM A 300X600 mm of PHOMI make,as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 and European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in‐charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in‐charge. Make-Phomi Ground Floor 107 First Floor 108 50013261 Providing, Fixing & Fitting Ceramic glazed tiles (SUPER PREMIUM QUALITY) on wall of size 300mmx600mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect. (JOHNSON/SOMANY/KAJARIA) [NSWI] Ground Floor 109 First Floor 110 EPH 111 10000556 Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH. Ground Floor 112 10000564 Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG). Ground Floor 113 10000570 Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG). Ground Floor 114 10000583 Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSB Ground Floor 115 10000588 Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme. Ground Floor 116 10000594 Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/Aerolex Ground Floor 117 10000596 Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation). Ground Floor 118 10000600 Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete. Ground Floor 119 10000602 Installation charges pump set with all accessories including transportation etc. Ground Floor 120 10001184 Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEX Ground Floor 121 10001190 Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.1.5HP, Single phase,32D,19 Stage (head 50-129m). Make: KSB(2C/21). Ground Floor 122 10001204 Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.7.5HP, Three phase, 100x75, Open well (head 14-29m) make: KSB ( MR7.5A/50X40X45) Ground Floor 123 FUR 124 50010482 Supply and fixing of GODREJ MAKE EXECUTIVE CHAIR WITH HEADMODEL NO- Aero (Large Seat) Black Ink Color FK01(56101522SD04692) +(561015 22SD04353).[NSWI] Ground Floor 125 50010484 Supply and fixing of GODREJ MAKE EXECUTIVE CHAIR WITH HEADMODEL NO- OXBO MID BACK CHAIR 7502RGC01 Black Ink Black56101522SD03157.[NSWI] Ground Floor 126 50011783 Supplying and installation of work station table of size 1050x600x750mm(H) having 25mm thick pre-laminated particle board top with 2mm thick PVC edge leaping on all exposed edges. The legs of the tables have 60x40mm and beams are 40x20mm MS powder coated. The vertical raceway with built in separator for power and data of size 250mmx70mm thick with provision to mount switches and sockets on laminate facia with vertical wire entry cover for wire uptakes from floor to raceway of 65mm dia wire manager grommet in complete set are provided. Make: Featherlite (HSN code-94031090) Ground Floor 127 50013340 Supplying and instllation of dining chair having Seat and Back made up of injection moulded indoor grade PolyPropylene compound SEAT SIZE : 52.5 cm. (W) x 53.2 cm. (D) BACK SIZE : 51.6 cm. (W) x 40.5 cm. (H) The powder coated ( DFT 50±10 microns ) welded tubular frame should be made from 0 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm and 3.5 ± 0.03 cm x 1.5 ± 0.03 cm x 0.16 ± 0.0128 cm MSERW tube. The shoes should be made of indoor grade PolyPropylene compound and snap fitted with tubular frame. Make: GODREJ ,Model-UNWIND, HSN CODE-94016900 Ground Floor 128 50013568 Supplying and installation of Table without CPU Hanger size shall be 1500 Width mm x 750 Depth mm x 728 Height mm . Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 and MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) . Make: Godrej ENTERPRISE, HSN CODE-94031010 Ground Floor 129 50014300 Storage Unit:Slimline 2 Door with full locker 1900H X 900W X 507D Supplying and placing in position Home storage Unit.900mm(W)x507mm(D)x1950mm(H) (Height without leveler). Construction & Material-Aesthetically appealing Slimline, completely knock down construction. Removable Skirting to cover integral legs. Legs fitted wit h screw type leveler Made from combination of CRCA 0.8 mm & 0.6 mm Thickness. Main Door Steel Hinged Door. Main Door Locking / handle: Handle & Base Aesthetically appealing, Ergonomic, flush with door made from Zinc alloy. 3 way 90 Degree Removable key type Cam lock & locking mechanism. Locker Door & it’s locking / handle for Model ‘H’ .Fixed Half locker on RH side Hinged Door 2 way Cam lock with Knob type handle Shelving: • Finish: Epoxy Powder coated to the thickness of 50 microns (+-10).HSN CODE-94032090 Ground Floor 130 50014302 Chair:Traverse 3 Seater 2 arms Providing, supplying and placing of waiting chair.SEAT/BACK SHELL: It is powder-coated shell made from cold rolled M.S. sheet 0.12 ± 0.013 cm thickness with circular perforations.The Side Bar is made of cold rolled M.S.sheet 0.12 ± 0.013 cm thickness. The Shell is assembled on the Cross Beam with help of M8 Bolts. SEAT SIZE : 50.0 cm (W) x 45.5 cm (D) BACK SIZE : 50.0 cm (W) x 56.0 cm (H)CROSS BEAM: It is made up of cold rolled steel with 0.2 ± 0.02 cm thickness. The crossbeam is powder coated. It is covered with plastic end caps LEG: It is made up of cold rolled steel with 0.12 ± 0.013 cm thickness. It is powder coated. The legs are fitted with leveller cups covered with SS304 sheet. ARMREST: It is made of SS304 round tube of Ø 3.175 ± 0.03cm x 0.12 ± 0.013 cm thick formed to make an oblong shape.WIDTH (W): 173.5 CM.DEPTH (D): 74.0 CM.HEIGHT (H): 91.0 CM SEAT HEIGHT (SH): 44.0 CM.HSN CODE-94031010 Ground Floor 131 50014304 Storage Unit:Pigeon Hole Base Supplying and placing in position Storage unitOverall Dimensions of Pigeon Hole Base 1800 H Main Modish Oak shall be 582mm(W)x400mm(D)x1200mm(H) . TheConstruction shall be Rigid Knock Down Construction . Material used shall be all side panels , top/bottom panels and shelf panels shall be made from 18 mm thick Pre- Laminated Board (interior grade) with 2 mm thick PVC edge beading . Back panel shall be made from 9 mm thick Pre- Laminated board . Stackability shall have Add on units stacked width wise to form a bank of racks having common side panel (max . 6 Add ons) . The shelfs shall be 6 Main Module has 12 shelves placing in 270 mm distance , 4 Main module has 8 shelves placing in 270 mm distance . The Configuration shall have 6 Main Module , 4 Main Module also 6 Add on module , 4 Add on module .HSN CODE-94031010 Ground Floor 132 50014306 Chair:Unwind with Desklet Providing, supplying and placing of chair with desklet.The Seat and Back should be made up of injection moulded indoor grade PolyPropylene compound SEAT SIZE : 52.5 cm. (W) x 53.2 cm. (D) BACK SIZE : 51.6 cm. (W) x 40.5 cm. (H) The powder coated ( DFT 50±10 microns ) welded tubular frame should be made from 0 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm and 3.5 ± 0.03 cm x 1.5 ± 0.03 cm x 0.16 ± 0.0128 cm MSERW tube. The shoes should be made of indoor grade PolyPropylene compound and snap fitted with tubular frame. The Armrest should be made of indoor grade PolyPropylene compound and assembled over the tubular frame. The L shaped desklet should be made of 1.8+-0.05cm thick prelaminated particle board with 0.2+-0.05cm thick injection moulded poly proplylene all around. Desklet should have back and front adjustment of 4.4+-0.5cm. The paper tray should be made of 0.4mm thick MS rod which is spot welded to form a mesh like structure. Overall Dimensions of Chair Seat Height - 45.0 cm. Height - 84.5cm. Width-57.5 cm and Depth-67.8 cm.HSN CODE-94016900 Ground Floor 133 50014308 VFC Filling Cabinet 1320H x 470W x 620D Supplying and placing in position Filling Cabinet Vertical Filing Cabinets whcih use less floor space. Size of 4 Drawer VFC shall be 1320mm(H) X 470mm(W) X 620mm(D). All the components shall be made of CRCA . It should have 1 Point Locking Mechanism and a Rigid Knock Down Construction. The Top, Side & Drawer Front thickness should be 0.7mm. The Frames, Drawer-inside cover and Side Back Side thickness should be 0.6mm. The Back, Bottom and Drawer thickness should be 0.5mm. Easy to grip Full length Recess Handle shall be integrated into Metal Drawer for easy pull out convenience. There shall be a Snap on type plastic label holder on Drawer Fronts. In addition, 28 ‘Ezee’ / ‘Visa’ files (Foolscap) from front to back of thickness 20mm per drawer can be hanged in VFC. The Centralized locking System shall be provided along with Shooting Bolt Mechanism and 10 Lever Cam Lock. The VFC should have anti-tipping arrangement which ensures that when one drawer is opened for use, it does not allow other drawers to be opened. The High Quality Precision Ball Slide shall be provided with Drawer Load capacity of max 40 kg and UDL for 75,000 cycles (BS). Plain Triangular plate pop should be riveted at the bottom corners for rigidity. Optional Accessories like Drawer Partition and Cradle for hanging A4 file folders front to back should also be available. The finishing shall include Epoxy powder coated to the thickness of 50.HSN CODE-94031010 Ground Floor 134 50014310 Bed:APO Bunk Bed+Mattress with Pillow Providing, supplying and placing of Bunk Bed BED FRAME BED FRAME ASSEMBLIES 2 NOS. ARE WELDED OF SIDE FRAME & INNER SLAT. THE SIDE FRA ASSEMBLY ARE MADE OF RECT. TUBE 50.8 x 25.4 X 1.2MM. ASSEMBLY INNER SLAT IS SQ. TUBE OF 25.4 X 1.2 MM THK MS ERW TUBE IS:7138 GRADE.HEAD BOARD & TAIL BOARD MOSOITO ROD:-HEAD BOARD & TAIL BOARD ARE MADE UP OF SO. PIPE 38.1 X 1.6MM THK, SQ 25.4 X 1.2MM THK MS ERW TUBE IS: 7138 GRADE SUPPORT BRACKET 3.2MM THK MS SHEET IS: 513 AND CONNECT WITH BED FRAME WITH MA NUT &BOLT,MOSQUITO ROD OF $19.0 X 1.0 MM THK MS ERW TUBE TO BE FIT IN #22 X 1.0MM THK MS ERW TUBE & BOTH TUBE IS OF IS: 7138 GRADE, HOOK IS PROVIDED AT THE TOP OF ALL ROD. LADDER ASLY - LADDER ASSY IS MADE UP OF RECT 50.8 X 25.4 X 1.2MM THK & SO. 25.4 X 1.2MM THK MS ERW TUBE IS: 7138 & CONNECTED WITH BED FRAME SIDE SUPPORT :- SIDE SUPPORT IS MADE OF #25.4 X 1.2MM THK & #19 X 1.2MM THK TUBE CONNECTED WITH BED FRAME USING MB NUT & BOLT. CLADDING -12mm THK PLY.HSN CODE-94032090 Ground Floor 135 50014312 Providing, supplying and placing of Personal Locker Product Size - 375(W) x 470(D) x 1950*(H) *Height including leveler* Height of leveler is 50mm and adjustment possible is 15mm. Construction & Material - Aesthetically appealing completely knock down construction.The add-on units are stack widthwise to form a row of Lockers. (Note- Single Main unit should not be offered. Minimum 1Main +1Addon to be offered, Maximum 1Main + 4Addon to be offered) Legs fitted with screw type leveler. Made from combination of Top panel(0.5mm CRCA), side panel(0.5mm CRCA), Bottom panel(0.5mm CRCA), Back panel(0.5mm CRCA), Top Bottom stiffener(1.2mm CRCA) and End Cover(0.5mm CRCA). ** - CRCA D Grade as per IS- 513 - CRCA D Grade as per IS-513Doors (Without envelope slot) - Made from 0.6mm Thick CRCA (D Grade, IS-513) Soft closing hinge.Door size - For 4 Door locker - 373(W) X 18(T) X 473(H)Cam Lock - Oval knob that functions as a handle- Click action mechanism- Key removal in locked and unlocked position- Zinc alloy die cast housing Shelving - 3 Shelves for 4 Door locker without envelope slot.HSN-94031010 Ground Floor 136 50014314 Cafepod Table Supplying and placing in position cafeteria table of the following specifications with size shall be 800 Width mm x 800 Depth mm x 742.5 Height mm . The top shall be stainless steel top of size : 800 mm x 800 mm x 1.2 mm thick . Top Assembly shall be 24 mm thick also top shall be made from 1.2 mm thick SS - 304 Brushed steel finish sheet . The Welded Stiffener assembly made from 0.6 mm thick SS - 304 sheet glued with top with special glue .Understructure shall be foldable and stackable , made with combination of aluminium and plastic . Centre column is of Aluminium extrusion of diameter 70 mm , which is anodized . Base is made in 2 pieces of die cast aluminium with buffed finish . It is bolted together with centre column and top flange .HSN CODE-94031010 Ground Floor 137 IPH 138 10000314 Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3- 2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification.Porcelin 23 inch LWC(ORISSA Pan) Ground Floor 139 10001056 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 mtr. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 20 mm outer dia CPVC pipes. Ground Floor 140 10001058 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 25 mm outer dia CPVC pipes. Ground Floor 141 10001060 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 40 mm outer dia CPVC pipes. Ground Floor 142 10001062 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 50 mm outer dia CPVC pipes. Ground Floor 143 10001064 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method; water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid for separately). 110mm dia. SWR pipe of Single Socket Push fit of class-3 (6Kg/Sq.cm). Make:- ORIPLAST/SUPREME/FINOLEX. 110mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor 144 10001066 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method with water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid separately). 160mm dia. rigid UPVC SWR pipe Class- 3 (6Kg/Sq.cm). Make: ORIPLAST/SUPREME/FINOLEX. 160mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor 145 10001068 Providing and fixing on wall face PVC 110 mm dia. offset SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. offset PVC SWR type. Ground Floor 146 10001070 Providing and fixing on wall face 110mm dia. single junction with door PVC SWR type moulded fittings, accessories for Rigid UPVC SWR pipes conforming to IS : 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion . Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Single Junction with door PVC SWR type. Ground Floor 147 10001072 Providing and fixing on wall face 110mm dia. plain bend PVC SWR type moulded fittings / accessories for Rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Plain Bend PVC SWR type. Ground Floor 148 10001074 Providing and fixing on wall face 110mm dia. bend with door PVC SWR type moulded fittings / accessories for rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Bend with door PVC SWR type. Ground Floor 149 10001076 Providing and fixing on wall face 110 mm dia. cowel PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. cowel PVC SWR type. Ground Floor 150 10001088 Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall. Ground Floor 151 10001094 Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm. Ground Floor 152 10001096 Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete, with cement concrete (1:3:6) and 12mm cement plaster (1:3) along with Cement punning. Ground Floor 153 10001098 Fixing floor traps of the following nominal diameter of outlet of self cleaning design with serewed down or hinged grating with or without vent arm complete includingcost of cutting and making good the walls and floors all complete as per specification. 110mm INLET & OUTLET FLOOR TRAP.make: ORIPLAST/SUPREME/FINOLEX 110mm Dia Inlet & Outlet floor trap PVC SWR type. Ground Floor 154 10001100 Providing and fixing EWC Commode floor mount(S/P trap) conforming to IS 2556: Part 3- 2004 duly fixed to head less socket caps/wall plugs and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per specification without cistern - Long pattern size 575x345x390mm. Make: Hindware POPULAR (CAT NO-20044 S-TRAP-28.5/P-TRAP-18.0)/Parryware ELITE (P-TRAP-CO278/S-TRAP-CO297) White Vitreous China Wash Down Water Closet (EWC). Ground Floor 155 10001102 Fixing of Back to wall WC with UF soft close seat cover, hinges, accessories set with rack bolt 12mm dia stainless steel Size(360x51 5x410mm) (FOR DISABLED) Floor Mounted to the floor fixed to head less socket caps/wall plugs and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification WITHOUT CISTERN. make: JAQUAR (DIS-WHT-9 3955P180UF)/ KOHLER(K-2983IN-S-O) DISABLED PERSON COMMODE Ground Floor 156 10001116 Providing and Fixing PVC LOW LEVEL CYSTERN conforming to IS 2556 : Part 3- 2004 SIZE 415X130X305mm.Make: Hindware SUPERB (CAT NO-50 8829)/Parryware SLIMLINE ECONOMY (E-8090).White Vitreous china 10 litre (full flush) capacity manually controlled low level flushing cistern with all fittings and fixtures. Ground Floor 157 10001118 Providing and fixing stainless steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Size 600X450X225mm Steel Sink Matt single bowl. Make: (Parry ware(C857272)/Hindware(KS FLAMINGO)). Stainless steel kitchen sink - 600X450X225mm Single bowl. Ground Floor 158 10001122 Providing and fixing of Standing urinal including connecting the urinal with 32mm dia. PVC waste pipe by means of white lead mixed with chopped hemp,15mm dia. PVC Reinforced heavy duty connection pipe etc. all complete as per specification. (White vitreous china clay half stall urinal flat back size-355X345X535 mm. Make: JAQUAR(URS-WHT-13261). Standing Urinal 355x345x535mm. Ground Floor 159 10001124 Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor 160 10001126 Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor 161 10001132 Providing and fixing of 15mm dia. CP Screw-down two way Bib Cocks (Taps)polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux headand high quality). Make: JAQUAR( CON-041KN)/ KOHLER (K-25432IN-4-CP). 15mm dia. Two-way Short body bib cock. Ground Floor 162 10001134 Providing and fixing of 15mm CP dia. Screw-down long body Bib Cocks (Taps) polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Headand high quality). Make: JAQUAR( CON-107KN)/ KOHLER (K-27490IN-CP) 15mm dia. Long body bib cock. Ground Floor 163 10001136 Providing and fixing of 15mm dia. CP Screw-down angle Stop Cocks with flange of the following nominal sizes as per specification complete. (Deluxe Head and high quality). Make: JAQUAR (CON-059KN))/ KOHLER (K-11568IN-7B-CP). 15mm diameter Angle Stop Cock. Ground Floor 164 10001138 Providing and fixing of Screw-down 15 mm CP concealed Stop Cock with fitting sleeve, operating lever and adjustable wall flange and concealed body conforming to of the following nominal sizes as per specification complete. (Deluxe Headand high quality). Make: JAQUAR-(CON-083FTK+ALD-083FT). 15mm diameter Concealed Stop Cock. Ground Floor 165 10001140 Providing and fixing of 15mm dia. CP overhead shower rose 100mm round with rubit cleaning system including polishing all complete as per specification.(Deluxe Head and Heavy quality). Make: JAQUAR (OHS-1989)/ KOHLER (K-163561N-A-CP). 100 mm diameter / 15 – 20 mm width shower rose. Ground Floor 166 10001142 Providing and fixing of 15mm dia. CP shower arm 160mm long light body round shape for wall mounted with flange. including polishing all complete as per specification. (Deluxe Head and Heavy quality). Make: JAQUAR (SHA -477)/ KOHLER (K-99054IN-CP). 15 mm x 160 mm long size CP shower arm. Ground Floor 167 10001146 Providing and fixing of health faucet with 1.2m long PVC tube and wall hook. Make: JAQUAR (ALD-563) including all complete as per specification. 1.2m long PVC tube CP health Faucet. Ground Floor 168 10001148 Providing and fixing Stainless Steel soap dish holder fixed to head less socket caps, wall plugs with CP brass screws as per specification. Make: JAQUAR (ACN-1131N))/KOHLER (K-10712D-CP). Stainless Steel Soap Dish Holder. Ground Floor 169 10001150 Providing and fixing of 600x120 mm glass Shelf with anodised aluminium angle frame with chromium plated brassbrackets and guard rails of required size complete, fixed to head less socket caps, wall plugs with chromium plated brass screws as per specification. Size 600x120 mm glass shelf. Make: AQUAR-(ACN-1171N)/ KOHLER(K5636IN-CP). 600mmX120mm Glass Self. Ground Floor 170 10001152 Providing and fixing standard sized stainless steel towel rail of 600mm long complete with Chromium Plated brass brackets; fixed to head less socket caps, wall plugs with Chromium Plated brass screws, complete as per specification. (Make: JAQUAR (ACN-1111SM)/ KOHLER (K-5630IN-CP),(Heavy quality). 25 x 600 mm long SS Towel Rail. Ground Floor 171 10001154 Providing and fixing standard sized stainless steel towel ring with round flange complete with Chromium Plated brass brackets; fixed to head less socket caps/wall plugs with Chromium Plated brass screws, complete as per specification. Make: JAQUAR (ACN-1121BN) /KOHLER (K-5631IN-CP). SS Towel ring with round flange. Ground Floor 172 10001158 Providing and fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to head less socket caps, wall plugs and washers complete as per specification.(AR-2013,SL. NO.-3.4.26). Make: Mirror Glass (SAINT GOBIN/AIS(ASAHI)). 600mm x450mm Bevelled Edge Mirror (Heavy quality). Ground Floor 173 10001160 Providing and fixing Rotational moulded polyethylene cylindrical vertical water storage tank 3layer wall conforming to IS : 12701--1996 including cutting holes through the tank and fixing, fittings CPVC tubes and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting up to a height of 5 metres above ground level and placing the tank to the required position etc. all complete as per specification. Make: SINTEX/SUPREME/ORIPLAST. Triple Layer Cylindrical Vertical water storage tanks. Ground Floor 174 10001166 Fixing wash basins WITHOUT PEDESTALwith hole for pillar taps with 10mm dia M S rack bolt (JAQUAR MAKE) painted white including cutting holes in walls and making good the damages etc all complete, with fixing of 15mm dia pillar cock, as per specification.(Vitreous china flat back wash basin 550x400x200 mm)(CODE CNS-WHT-801 JAQUAR MAKE).Pillar cock(CON-021 JAQUAR)32mm full/half thread CP waste(ALD-705/709-JAQUAR), Rack bolt(ZPS-MST-RB03)Vitreous china flat back wash basin 550x400x200mm . Ground Floor 175 10001170 Providing and fixing of Metropole flush valve dual flow,32mm concealed body with exposed shutoff provision and 100mm square plate, 3.0/6.0 litre per flushing. Make: JAQUAR (FLV-1085 NSQ),fixing accessories with accessories set. Concealed Flushing Cistern. Ground Floor 176 10001172 Providing and fixing of 692mm long stainless steel grab bar handle (FOR DISABLED)fixed to head less socket caps, wall plugs and chromium plated screws as per specification . Make: JAQUAR (WAC-WHT-BR0600N) 692mm long stainless steel grab bar handle. Ground Floor 177 10001174 Providing and fixing of stainless steel vertical swing grab bar (FOR DISABLED) fixed to head less socket caps, wall plugs and chromium plated screws as per specification. Make: JAQUAR (WAC-WHT-BG0800N) Stainless steel vertical swing grab bar. Ground Floor 178 10001209 Providing and fixing curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish size H:900XW:450mm with stainless Steel brackets including cutting holes in wall and making good the damages etc. complete as per specification. Make: JAQUAR (JSE-CHR-110UC450X/110US450X). Curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish. Ground Floor 179 MIS-CVL-Area Concr 180 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 181 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 182 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 183 50001782 Filling bitumen and cement and jute fibre in expansion joints inclusive of cost of materials, bitumen and cement propertion(3:1), including cleaning before pouring 12mm to 25mm and 15 cm depth. Ground Floor 184 50011616 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING) Ground Floor 185 50013548 Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Ground Floor 186 MIS-CVL-Area Pavin 187 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 188 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 189 50001701 Providing and laying 80 mm thick Factory made cement concrete interlocking Paver block of M40 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge. Ground Floor 190 50011883 Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 . Ground Floor 191 50013548 Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Ground Floor 192 MIS-CVL-Boundary w 193 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 194 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 195 50000008 Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 196 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 197 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 198 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 199 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 200 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 201 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 202 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 203 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 204 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 205 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 206 MIS-CVL-Bus Washin 207 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 208 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 209 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 210 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 211 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 212 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 213 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 214 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 215 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 216 MIS-CVL-CC Road 217 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 218 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 219 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 220 50001782 Filling bitumen and cement and jute fibre in expansion joints inclusive of cost of materials, bitumen and cement propertion(3:1), including cleaning before pouring 12mm to 25mm and 15 cm depth. Ground Floor 221 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 222 50011101 Providing and laying in position 200mm thick Tremix/VDF flooring P.C.C. M-30 grade concrete using 20mmnominal size HBG down graded chips for plain cement concrete work using cement content 400kg/cum as per approved design mix having continious agitated mixer,mis design of specified grade for reinforced cement concrete work and for VDF floorng using screed board vibrator,placing of filtermat(nylon cloth to act as very fine filter),top mat (large single PVC sheet),Vaccume process using vaccume pump about 0.08MPA which ruduces water content about 15-20% ,power trawelling,brooming,T&P Charges including power,loading,unloading and hire charges,making grooves of 6mm wide and 25mm deep @ 1.5m C/C both ways ,filling the joints with sealing compound of approved quantityGrade-A(Ref:DSR-SH 16.46.1) with cost of material ,labour,conveyance,royalty etc. complete basing on IS 256:2000 minimum slump is 25mm to 75mm and minimum thiockness is 125mm . Ground Floor 223 50011103 Painting runway/taxi/track/apron marking with adequate nos of coats (minimum 2coats) to give uniform finish with road marking paint Based on solvent based acrylic resin has UV resistant colours of superior make (water based) i/c cleaning the surface of all dirt scales, oil, grease and other foreign material etc. and lining out complete. For new road work. Ref: DSR-16.47.1.Make(Asian paints:APCOTRAK, Berger:ROAD MARKING PAINT, Dulux :PROFESSIONAL WEATHER SHIELD ANTI-CARB)[NEW-NSWI] Ground Floor 224 50011883 Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 . Ground Floor 225 50013548 Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Ground Floor 226 MIS-CVL-Cow Catche 227 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 228 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 229 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 230 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 231 50005727 Prividing,Fittin & fixing of cow catcher,made out of steel work (TATA make GI pipe circular hollow of 100 mm OD as per IS 1239[P-1] 4 mm thick) including RS joist of size ISLB 150X80 with cutting requird size ,welding using MS flat of 40X6mm size,fixing in position with approvd design and specification including all fitings and applying a priming coat of approvd steel primer etc all complete as per the direction & instruction of the Engineer-in-charge of the work.DATA FOR size 16X5= 80 sft Ground Floor 232 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 233 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 234 50011560 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS). Ground Floor 235 MIS-CVL-DG Shed 236 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 237 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 238 50000008 Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 239 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 240 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 241 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 242 50000884 Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. Ground Floor 243 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 244 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 245 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 246 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 247 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 248 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 249 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 250 50011936 Supplying and fixing of TATA Blue scope Steel Sheet Roofing of 0.52 mm thick as per attached Quoatation in roof drilling holes in wind ties including fixing of ridges valleys wind ties and cost of fittings.[NEW-NSWI] Ground Floor 251 MIS-CVL-Drivers R 252 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 253 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 254 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 255 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 256 First Floor 257 Second Floor 258 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 259 First Floor 260 Second Floor 261 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 262 First Floor 263 Second Floor 264 50000044 Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ). Ground Floor 265 50000057 Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height. Ground Floor 266 First Floor 267 50000568 Kotah stone flooring in floors,treads rise and landing on 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing etc complete including cost of tile, material, labour T & P etc complete. Ground Floor 268 50001152 Providing & fixing aluminium work (min.thickness of powder coating 50 micron) for structural glazing including required scaffolding for fixing the aluminium sections for extruded builtup standard tubural & other sections of approved make confirming to IS:733 and IS:1285 fixing with rawl plugs & screws or with expansion hold fasteners including necessary fillings up gaps at junctions at top,bottom & sides with cement mortar,aluminium sections shall be smooth,rust free ,straight,mitred & jointed mechanically,the glazing will be 5mm thick,coloured,reflective glass of approved colours & make (SAINT GOBAINI) fixed in aluminium sections upto required height & joints filled clear weather silicon sealant etc complete in all respect as per the direction of EIC/Architect in charge. Ground Floor 269 First Floor 270 Second Floor 271 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 272 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 273 First Floor 274 Second Floor 275 50001311 Fly Ash brick masonary in cement mortar 1:4:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 276 First Floor 277 50005074 Supplying, installing RO +UV+UF+TDS control+UV in-tank and zero water wastage technology with active cupper technology, wall mounted water purifier aquaguard capacity up to 20L/hr(Make KENT-grand star/Eureka Forbes)[N.S.W.I] Ground Floor 278 50010026 Supplying, Fitting and fixing of glass reinforced concrete(GRC) screens 30mm to 32mm thick (Dry density>1800 kg/cum) on wall (Wall cladding) and module of 1.5 sqm of approved quality/ pattern shall be synthetic rubber/ FRP moulded in size, pattern, design, colour and thickness. The screens made of 53 grade white cement make Birla/JK cement, quartz, fine silica sand, alkali resistance glass fiber, super plastisizer, polymers and UV resistant synthetic inorganic pigments etc. The screen shall be fixed by dry fixing method with appropriate SS pipe 304 grade ‘L’ shaped clamps & cleat, using fasteners and necessary hardware, etc. Including MS scaffolding in building façade. The rate shall be included the structural steel frames (Horizontal & vertical members) support to hold the GRC jalli at required building height to withstand wind pressure as per IS 875(prt-3):2015. The cost includes labour, materials, transportations, T&P, etc. all complete as per direction of Engineer-in-Charge. The screen must have compressive strength>400kg/cm2 ,wet transverse strength > 7 N/mm, thermal conductivity1.63 W/m-K at 3% moisture content, water absorption<(><<)> 5% of dry weight. [NEW-NSWI] Ground Floor 279 First Floor 280 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 281 First Floor 282 Second Floor 283 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 284 First Floor 285 Second Floor 286 50010384 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC SILL BAND) Ground Floor 287 First Floor 288 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 289 50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor 290 First Floor 291 Second Floor 292 50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor 293 First Floor 294 Second Floor 295 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 296 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 297 First Floor 298 Second Floor 299 50010458 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement. (FOR RCC FINS) Ground Floor 300 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 301 First Floor 302 Second Floor 303 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 304 First Floor 305 Second Floor 306 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 307 First Floor 308 Second Floor 309 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 310 First Floor 311 Second Floor 312 50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor 313 First Floor 314 Second Floor 315 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 316 First Floor 317 Second Floor 318 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 319 First Floor 320 Second Floor 321 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 322 First Floor 323 Second Floor 324 50010668 Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/Green Ground Floor 325 First Floor 326 50010680 Providing and fixing of ISI marked 30 mm thick Flush door Shutters (Single leaf) finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125 mm x 85 mm x 5.5 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 1 No SS Aldrop (400mm X 300mm x 16mm dia rod), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials,adhesives etc complete. (Excluding door closure, ornamental handle and Mortise Lock). [NSWI] Make:- BWP Flush door (Century Sainik 710 / Green marine gold 710), Laminate (Greenlam/ Centurylam,Marino),Hard ware fittings (Godrej). Ground Floor 327 First Floor 328 50010704 Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej). Ground Floor 329 First Floor 330 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 331 First Floor 332 Second Floor 333 50010827 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL. Ground Floor 334 First Floor 335 50010839 Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX. Ground Floor 336 First Floor 337 50010975 Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb). Ground Floor 338 First Floor 339 50011029 Providing and painting the mural art painting work on wall/floor/ceiling by the selected artist/ agencies to make the art most visible of the stretch. The work includes scraping and cleaning of wall, painting one primer coat and one weather seal coat (Asian/ Berger/Dulux), applying paint for mural art painting. The paint must have a durability of at least 5 years. The cost of the work includes all the labour, man power, scaffolding, transportation, materials required, fooding, etc. for execution of the mural art to give the finish product. It must be noted that, the height shall be calculated from the point where the painting starts till the point it continues and ends. UPTO 3M HEIGHT Ground Floor 340 First Floor 341 50011397 Providing and fixing of factory-made 2Track 2Panel uPVC Sliding window (White Colour) frame size 70X50mm and Sash size 45X60mm complete up to and including 1.5m high, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber. The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 5mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 5 mm clear Toughened glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep glass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN) Ground Floor 342 First Floor 343 50011406 Providing and fixing of factory-made 3Track 3Panel UPVC Sliding window (White Colour) frame size 128X50mm and Sash size 45X70mm complete up to and including 1.5m high, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber. The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 5mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 5 mm clear Toughened glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep glass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN) Ground Floor 344 First Floor 345 Second Floor 346 50011486 Supplying, Fitting & Fixing of Anti-Skid Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 600mm x 9 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY TECHSTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL) Ground Floor 347 First Floor 348 50011926 Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF) Second Floor 349 50011984 Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification. Ground Floor 350 First Floor 351 50012200 System Aluminum Casement System Doors – Double Leaf Swing single glazed door Providing and fixing System Aluminum works for casement systems door having door frame 55mmx40mm, shutter 70mmx40mm, door bottom transom 150mmx40mm, central profile 47.3x42.9mm, grazing bead 31.8mmx17.85mm with glazing of single glass panel without middle transom made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. The drainage slots provided at the bottom part of the frame/sash on the outerside & weather strip siliconased brush gasket will be provided. 6mm Clear Toughend Glass (Saint-Gobain / AIS) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. The casement systems having hardwares SS handle (22mmx300mm), mortise lock with both side key cylinder, floor spring. Wall Thickness - Aluminium: 1.5mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD) Ground Floor 352 50012828 Supply and fixing of MCM Modified Clay Material ‐ MCM A 300X600 mm of PHOMI make,as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 and European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in‐charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in‐charge. Make-Phomi Ground Floor 353 First Floor 354 50013241 Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 600mm x 10 mm with s elf-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete.The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) [NSWI] Ground Floor 355 First Floor 356 50013261 Providing, Fixing & Fitting Ceramic glazed tiles (SUPER PREMIUM QUALITY) on wall of size 300mmx600mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect. (JOHNSON/SOMANY/KAJARIA) [NSWI] Ground Floor 357 First Floor 358 MIS-CVL-EV Chargin 359 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 360 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 361 50000008 Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 362 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 363 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 364 50005597 Providing TEXTURED POLYCARBONATE sheet with all its accessories etc complete as per the direction & instruction of the E.I.C. [N.S.W.I] Ground Floor 365 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 366 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 367 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 368 50011496 Supplying, Fitting & Fixing of Industrial parking heavy duty Vitrified Tile (PREMIUM QUALITY) on floors of size 300mm x 300mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY DURASTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL) Ground Floor 369 MIS-CVL-Entry & Ex 370 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 371 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 372 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 373 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 374 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 375 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 376 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 377 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 378 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 379 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 380 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 381 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 382 MIS-CVL-Inspection 383 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 384 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 385 50000008 Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 386 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 387 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 388 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 389 50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor 390 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 391 MIS-CVL-Land Scapi 392 50002295 Planting of Nerium Olender 3 ht. ornamental plants, well established healthy disease free in poly bag/ big container Including transportation and delivery at sites. Ground Floor 393 50005655 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts Unit = Sqm (CPWD 2.12,P-217)[N.S.W.I] Ground Floor 394 50005657 Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment) (CPWD 2.2,P-213)[N.S.W.I] Ground Floor 395 50005659 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm (CPWD 2.4.3,P-214)[N.S.W.I] Ground Floor 396 50005661 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).(CPWD 2.8,P-216)[N.S.W.I] Ground Floor 397 50005663 Providing & laying Selection no. 1 grass turf(Bermuda) with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge (CPWD 2.34,P-235)[N.S.W.I] Ground Floor 398 50005667 Planting of Murraya exotica 20 ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites. This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 8.46,p-372= Rs.15.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 154.49.[N.S.W.I] Ground Floor 399 50005669 Planting of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara, Mohan, Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) 45cm ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant9.40,p-381= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25 ,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49 Ground Floor 400 50005671 Planting of Malpighia coccigera 21/2 ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 8.45,p-372= Rs.50.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 189.49[N.S.W.I] Ground Floor 401 50005673 Planting of Tecoma grandiflora 21/2 ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 9.13,p-383= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49 Ground Floor 402 50005675 Planting of Allamanda cathartica 30 ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 9.10,p-381= Rs.45.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x0.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 184.49[N.S.W.I] Ground Floor 403 50005677 Planting of Jasmine humile (Yellow) o 30 ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites. This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 9.90,p-382= Rs.30.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x0.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 169.49.[N.S.W.I] Ground Floor 404 50005681 Planting of Hena 20 ht. well grown healthy plant species as per specified height all saplings are healthy grown well canopy,disease free etc. including transportation and delivery at sites.This cost is including hoeing soil of size 2dia and 2 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge . Plant 8.50,p-373= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49(Say Rs.180.00)[N.S.W.I] Ground Floor 405 50005683 Planting of Fox tail palm 70 ht.ornamental decorative specimen plants well established healthy disease free in poly bag / big container including transportation and delivery at sites.Planting of each plant at specified location by application of fortilizer and pesticide as required as per instructio of Officer in-charge.This cost is including hoeing soil of size 3dia and 3 depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge . a) plant 5.3,p-324=Rs.1183.00, stacking 7.44,p-349= Rs.650.00, digging hole 2.14.1,p-218= Rs 214.77, antitermite 2.54,p-246=Rs.92.68, shaping 2.38 ,p-236=Rs.53.60, cattle manure 2.25,p-224=Rs.374.12, fencing 2.23Sqm 2.58,p-248= Rs. 193.58x2.23= Rs 431.68 Total cost=2999.85(say Rs.3000.00) [N.S.W.I] Ground Floor 406 50006323 Filling & Leveling of site by JCB.[N.S.W.I] Ground Floor 407 50006324 Supplying planting of fruit plants including digging the pit & required quantity of fertilizer & pesticides such as mango water apple, jack fruit,guava, custand apple,count., lichu, jamun,star fruit ,tamarind,citrus lime,sapeta etc. Two to three year olds slpping at least two to six ft height depend on species as per direction of E.I.C.[N.S.W.I] Ground Floor 408 50006326 Maintenance Per Month including fertilizer pesticide, man power,grass cutting, straining, Seasonal flower all etc.[N.S.W.I] Ground Floor 409 MIS-CVL-Market Com 410 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 411 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 412 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 413 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 414 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 415 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 416 50000044 Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ). Ground Floor 417 50000057 Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height. Ground Floor 418 50000937 Supply, Fitting and Fixing of Rolling Shutter including cost of Material & Labour Ground Floor 419 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 420 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 421 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 422 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 423 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 424 50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor 425 50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor 426 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 427 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 428 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 429 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 430 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 431 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 432 50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor 433 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 434 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 435 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 436 50010815 2.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete. Ground Floor 437 50010839 Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX. Ground Floor 438 50010975 Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb). Ground Floor 439 50011029 Providing and painting the mural art painting work on wall/floor/ceiling by the selected artist/ agencies to make the art most visible of the stretch. The work includes scraping and cleaning of wall, painting one primer coat and one weather seal coat (Asian/ Berger/Dulux), applying paint for mural art painting. The paint must have a durability of at least 5 years. The cost of the work includes all the labour, man power, scaffolding, transportation, materials required, fooding, etc. for execution of the mural art to give the finish product. It must be noted that, the height shall be calculated from the point where the painting starts till the point it continues and ends. UPTO 3M HEIGHT Ground Floor 440 50011926 Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF) Ground Floor 441 50011984 Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification. Third Floor 442 50013241 Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 600mm x 10 mm with s elf-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete.The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) [NSWI] Third Floor 443 MIS-CVL-Pump room 444 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 445 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 446 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 447 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 448 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 449 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 450 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 451 50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor 452 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 453 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 454 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 455 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 456 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 457 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 458 50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor 459 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 460 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 461 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 462 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 463 50010827 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL. Ground Floor 464 50011560 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS). Ground Floor 465 MIS-CVL-RCC Drain 466 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 467 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 468 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 469 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 470 50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor 471 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 472 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 473 MIS-CVL-Security S 474 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 475 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 476 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 477 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 478 50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor 479 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 480 50000044 Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ). Ground Floor 481 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 482 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 483 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 484 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 485 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 486 50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor 487 50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor 488 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 489 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 490 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 491 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 492 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 493 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 494 50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor 495 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 496 50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor 497 50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor 498 50010668 Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/Green Ground Floor 499 50010680 Providing and fixing of ISI marked 30 mm thick Flush door Shutters (Single leaf) finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125 mm x 85 mm x 5.5 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 1 No SS Aldrop (400mm X 300mm x 16mm dia rod), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials,adhesives etc complete. (Excluding door closure, ornamental handle and Mortise Lock). [NSWI] Make:- BWP Flush door (Century Sainik 710 / Green marine gold 710), Laminate (Greenlam/ Centurylam,Marino),Hard ware fittings (Godrej). Ground Floor 500 50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor 501 50010815 2.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete. Ground Floor 502 50010975 Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb). Ground Floor 503 50011029 Providing and painting the mural art painting work on wall/floor/ceiling by the selected artist/ agencies to make the art most visible of the stretch. The work includes scraping and cleaning of wall, painting one primer coat and one weather seal coat (Asian/ Berger/Dulux), applying paint for mural art painting. The paint must have a durability of at least 5 years. The cost of the work includes all the labour, man power, scaffolding, transportation, materials required, fooding, etc. for execution of the mural art to give the finish product. It must be noted that, the height shall be calculated from the point where the painting starts till the point it continues and ends. UPTO 3M HEIGHT Ground Floor 504 50011426 Providing and fixing of factory-made 3Track 3Panel UPVC Sliding window/Door (White Colour) frame size 128X50mm and Sash size 45X74mm completeabove 1.5m high, comprising UPVC multi-chambered frame having in-built UPVC roller track on top and UPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber.The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 6mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 6 mm clear Toughened glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock & Multi Lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep gl ass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN) Ground Floor 505 50011926 Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF) Ground Floor 506 50011984 Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification. Ground Floor 507 50013241 Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 600mm x 10 mm with s elf-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete.The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) [NSWI] Ground Floor 508 MIS-CVL-Septic tan 509 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 510 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 511 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 512 50000018 4 thick dry brick rammed khoa well watered and fully consolidated complete,including cost of all materials as per direction of Engineer-in-charge. Ground Floor 513 50000019 25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. Ground Floor 514 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 515 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 516 50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor 517 50001839 Fly Ash brick masonary work in cement mortar 1:4 (1 cement : 4 sand) using fly ash bricks of 23cm X 11cm X 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/-2% including watering,curing and cost,conveyance,royality of all m aterials and cost of labour etc complete.As per the direction of the E.I.C. Ground Floor 518 50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor 519 50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor 520 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 521 MIS-CVL-Site Devel 522 50001792 Supplying, filling or Spreading of moorum by mechanical means including cost of all labour,material T & P etc. complete as per the direction of Engineer-in-charge. Ground Floor 523 MIS-CVL-Water Puri 524 50008261 Supplying and fixing Aquaguard Storage Cooler–Cum-Purifier (80 Ltr. Capacity ) with all cost complete.[N.S.W.I] Ground Floor 525 MIS-CVL-Workshop 526 50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor 527 50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor 528 50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor 529 50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 530 First Floor 531 50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor 532 First Floor 533 50001303 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth Ground Floor 534 50001305 Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure. Ground Floor 535 First Floor 536 50001692 Supplying, fitting,fixing and hoisting joists & M.S trusses and placing in position including cost of labour materials transportation etc.(make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)) Ground Floor 537 50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor 538 First Floor 539 50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor 540 50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor 541 First Floor 542 50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor 543 50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor 544 First Floor 545 50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor 546 First Floor 547 50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor 548 First Floor 549 50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor 550 First Floor 551 50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor 552 First Floor 553 50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor 554 First Floor 555 50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor 556 First Floor 557 50010813 Supplying, Fitting and Fixing Industrial Parking Vitrified Floor Tile of 10mm thick (SIZE 300X 300MM)on parking of approved shade laid on 25 mm thick cement mortar (1:1) and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T and P etc required for the works all complete. (For new work only) [NSWI]. Tile make:-NITCO/RAK/VARMORA , Epoxy Grout make:- ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout). Ground Floor 558 50010975 Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb). Ground Floor 559 First Floor 560 50011936 Supplying and fixing of TATA Blue scope Steel Sheet Roofing of 0.52 mm thick as per attached Quoatation in roof drilling holes in wind ties including fixing of ridges valleys wind ties and cost of fittings.[NEW-NSWI] Ground Floor 561 50011984 Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification. Ground Floor 562 MIS-INE-ADMIN BUIL 563 40000946 Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 564 40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 565 40000952 Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-bell push switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 566 40000958 Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/TV socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK). Ground Floor 567 40000961 Recessed wiring to Telephone Point (socket)with 2 pair 0.5sqmm telephone cable with 20 mm dia non metalic PVC flexible conduit with socket ISI marked MS Box including all accessories and connection.( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-s witch-Telephone socket -Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK). Ground Floor 568 40000967 Recessed wiring to Ceiling Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 569 40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 570 40000973 Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 571 40000976 Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 572 40000979 Recessed wiring to Security Light Point ( MODULAR) (4X24WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 573 40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 574 40000985 Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 575 40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 576 40000991 Point wiring for Computer Point ( MODULAR) with 2.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with3 Nos of 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 577 40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor 578 40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK) Ground Floor 579 40001006 Recessed wiring to submain in 2 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.4)(Make of PVC pipe-AKG/NORPACK) Ground Floor 580 40001012 Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.10)(Make of PVC pipe-AKG/NORPACK) Ground Floor 581 40001015 Recessed wiring to submain in 4 x 10 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.11)(Make of PVC pipe-AKG/NORPACK) Ground Floor 582 40001039 Supply and laying of 50 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 583 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 584 40001129 Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor 585 40001135 Supplying and fixing of 8X10 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam) Ground Floor 586 40001141 Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421)(Make-switch/Socke t-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 587 40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 588 40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 589 40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 590 40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 591 40001172 Supply of U-type fan hook(Make-TATA) Ground Floor 592 40001190 Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30) Ground Floor 593 40001193 Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells) Ground Floor 594 40001234 supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 595 40001258 SUPPLY & FIXING OF POWER DISTRIBUTION BOX,MAKE-NET RACK/VAL RACK Ground Floor 596 40001703 Supply and fixing of 2 way single door MCB box with 1 no 32 AMP DPMCB with sheet steel encloser,distribution board,on surface /recess,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar,detachable gland plate,interconnection,phosphate and power painted including earthing etc as required(Sl no-2.3.6,2.7)[Make-(a)MCB -Legrand/L &T/ABB/SCHNIDER Ground Floor 597 40001876 Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion(Make-Legrand/wipro/Anchor-Panasonic) Ground Floor 598 40001879 Recessed wiring in 1X1.5sqmm (For inverter)/DG wiring )FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK) Ground Floor 599 40002095 Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 600 40002179 Recessed wiring to Surface Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection .( Make of wire Finolex / L &T / Anchor / Havells/ V guard)Make-switch /-Legrand /Wipro /Anchor /havells /Panasonic) Ground Floor 601 40002886 Recessed wiring to bay light Point ( MODULAR) (45WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard/HPL) Make-switch/etc-Legrand /Wipro /Anchor /havells /Panasonic) Ground Floor 602 40002987 Supply of 20 port Mobile Charging Station including all accessories and connections. Ground Floor 603 40007569 Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate. Ground Floor 604 40007573 Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. Ground Floor 605 40007577 Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. Ground Floor 606 40007703 Supply and fixing of Main Panel board -I/C. 100 A 4P on load change over switch-1 no, 100 Amp four pole MCCB with stud connector (36 KA) -1 No, Bus bar - 4Nos 250 Amp,500 V copper strip , drum insulator for bus bar - 8 Nos & Bus bar sleeving -1 Job , O/G-63 Amp 4P MCB with Stud connector -2 Nos ,40 Amp FPMCB stut connector-2 Nos,63 A DPMCB with Stut connector-2 nos,32 A DPMCB with Stut connector-4 Nos with sheet metal powder coating and door gasket ,door hinges,door locks ,wiring and socketing [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)-Voltmeter,Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK] Ground Floor 607 40008024 Providing and fixing Carbon-di-oxide fire extinguishers. Capacity 4.5 kg. ISI Marked.(Make -Fire shield/Kanex/Safex ) Ground Floor 608 40008035 Sand Bucket as per IS specification . Ground Floor 609 40008037 Bucket stand to store 3nos of Bucket also having aluminium sheet above the atand to prevent the sand from rain/Sunset. Ground Floor 610 40008126 Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR) Ground Floor 611 40008132 Supply & fixing of 600MM (24) WALL MOUNTED AIR CIRCULATOR FAN WITH COMPLETE ACCESSORIES[BROWN/WHITE].including hanging and connections as per instruction of Electrical Engineer-in-charge[MAKE- USHA MODEL-DOMINAIRE WALL/CROMPTON MODEL-ACVOTEX24 WM/HAVELLS/V-GURAD /ANCHOR-PANASONIC) Ground Floor 612 40008142 Supply and fixing of 6 way mcb Box ( 8+18)(BDB) with I/C- 32 AMP 4PMCB & O/G-25AMP DP RCCB (100MA)-3 NOS&10 AMP SP MCB -12NOS with sheet steel encloser ,distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection ,phosphate and power painted including earthing etc as required.Make-MCB-(Legrand/L &T/ABB/SCHNIDER) Ground Floor 613 40008150 Supply and fixing of 6 way mcb Box ( 8+18)(PDB) with I/C- 63 AMP 4PMCB + 63 AMP 4P RCCB (300MA) & O/G- 20 AMP SP MCB -09 NOS&16 AMP SP MCB -09NOS with sheet steel encloser ,distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection ,phosphate and power painted including earthing etc as required.[Make-(a) MCB/MCCB-Legrand/L&T/ABB/SCHNIDER Ground Floor 614 40008158 Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO) Ground Floor 615 40008385 Supply and fixing of on 15 watt round/square shape slim recessed mounted led panel with dia cast housing finished in white powder coating False ceiling with comprises of aluminium die cast housing finished in white powder coated & ABS white ring . The downlighter is pre-wired with high efficiency electronic driver. High traslucent frosted diffuser is used to get glare free, smooth light distribution. Operating Voltage Range : 150V~ - 270V, PF : > 0.9, 100 Lum/Watt with lamp , choke, connecting wire, and all accessories and connections .( Make- CROMPTON(MODEL NO-LSCRM-15W-CDL/LSCSM-15W-CDL)/ PHILIPS(MODEL NO-15W DURASLIM ROUND/SQUARE 165MM/WIPRO(MODEL NO-LD80-131-XXX-60-XX) Ground Floor 616 40008387 Supply and fixing of on 24 watt round/square shape slim recessed mounted led panel with dia cast housing finished in white powder coating False ceiling with comprises of aluminium die cast housing finished in white powder coated & ABS white ring . The downlighter is pre-wired with high efficiency electronic driver. High traslucent frosted diffuser is used to get glare free, smooth light distribution. Operating Voltage Range : 150V~ - 270V, PF : > 0.9, 100 Lum/Watt with lamp , choke, connecting wire, and all accessories and connections .( Make- CROMPTON/ PHILIPS(MODEL NO-22W DURASLIM ROUND/SQUARE 208 MM/WIPRO(MODEL NO-LD80-281-XXX-60-G1) Ground Floor 617 40008393 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001) Ground Floor 618 40008397 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4/ WIPRO(MODEL NO-LL20-221-XXX-65NE3) Ground Floor 619 40008399 Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-415-25-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP029 LED25S 25W 2500LM)/ WIPRO) Ground Floor 620 40008405 Supply & fixing of 90 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 having LM 79 LM 80 tested including bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire with all accessories . (Make- CROMPTON(MODEL NO-TRP-412-90-57-SL-LM-NSG)/PHILIPS(MODEL NO-BRP033 LED90S 90W 9000LM)/WIPRO(MODEL NO-LR08-102-XXX-57-XX ) Ground Floor 621 40008495 Supply of 6U wall mounted rack including all accessories and connection(make-D-link(Model no-NWR-6U-5545-GR)/MOLEX/DIGISOL) Ground Floor 622 40008505 Supply & fixing of cat-6 UTP cable,4 pair,23AWG,FRPVC CM for LAN wiring with conduit pipe / PVC casing caping / under floor G.I. Tunk line. MAKE- D-LINK(MODEL NO-NCB-C6UGRYR)/DIGISOL/MOLEX) Ground Floor 623 40008507 Supply & fixing of patch cord,cat-6,utp,24awg,grey,lszg ,1mtr(Make-D-LINK(MODEL NO-NCB-C6UGRYR1-1-LS)/DIGISOL/MOLEX) Ground Floor 624 40008509 Supply & fixing of patch cord,cat-6,utp,24awg,grey,lszh ,2mtr(Make-D-LINK(MODEL NO-NCB-C6UGRYR1-3-LS)/DIGISOL/MOLEX) Ground Floor 625 40008511 Supply & fixing of information outlet with faceplate,single port ,modular straight shu and keystone,cat-6 utp,white,toolless type(MAKE-D-LINK/MOLEX/DIGISOL) Ground Floor 626 40008513 Supplying & fixing of patch panel ,24 PORT,CAT-6 UTP 180 Degree including all accessories and connections(Make-D-Link(Model N o-NPP-C61BLK241)/MOLEX/DIGISOL) Ground Floor 627 40008585 Supply and fixing of surface mounted led 18 w square/round light with powder coated finished in white housing 1with lamp , choke, connecting wire, and all accessories and connections .(Make- CROMPTON(MODEL NO-LCDSPLN-R-18-CDL/LCDSPLN-S-R-18-CDL)/WIPRO(MODEL N O-LD80-171-XXX-60-SM/PHILIPS(MODEL NO-20W Rd Metal FullGlow LED Surface ) Ground Floor 628 40008586 Supply and fixing of 24 Port Gigabit Smart Managed Switch with 4 Gigabit SFP Ports including all accessories and connection(Make-D-LINK(MODEL NO-DGS-1210-28)/DIGISOL (MODEL NO-DG-GS1528)/MOLEX) Ground Floor 629 40008703 Supply and fixing of 60wt Ceiling mounted high bay LED luminarie with LED lamp including all accessories and connection.(Make- Crompton model-TIP-311-70-57-SL-CP-NSG /wipro/philips) Ground Floor 630 40009312 Supply and installation of 1.5Tr.(5 Star) Inverter Split type Air Conditioner with supply and fixing of 4 KVA ,130-280 Volt voltage range wall/floor mounted stabiliser including all accessories,fastner angle copper piping up to 10ft & connections MAKE of A.C. – CARRIER MODEL NO-EMPERIA DXI/BLUE STAR MODEL NO-IA518ENU,MAKE OF STABILIZER- AUTOTEK/V-GUARD/MICROTEK Ground Floor 631 40009316 Supply and installation of 2.0Tr.(5 Star) Inverter Split type Air Conditioner with supply and fixing of 5 KVA ,130-280 Volt voltage range wall/floor mounted stabiliser including all accessories,fastner angle copper piping up to 10ft & connections MAKE of A.C. – CARRIER MODEL NO-EMPERIA DXI/BLUE STAR MODEL NO-IA/IC524DNU,MAKE OF STABILIZER- AUTOTEK/V-GUARD/MICROTEK Ground Floor 632 40010369 Supply & laying of 75mm Dia HDPE pipe PN - 6 PN - 80 required for cable laying. Make - Magunm, Supreme, Sudhakar. Ground Floor 633 MIS-INE-AREA ILLUM 634 40001024 Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI) Ground Floor 635 40001033 Supply and laying of 25 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/Polycab/KEI) Ground Floor 636 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 637 40001367 Supply and laying of 16 sq.mm 4 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 638 40002155 Supply and fixing of 16 sq.mm 04 core PVC Al. Arm Cableof 1.1 KV grade end termination.(Brass compression) Ground Floor 639 40002239 Supply and laying of 2.5Sqmm 3 Core Cupper Cable 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick (Make of wire Finolex/L &T/Anchor/Havels/V Guard) Ground Floor 640 40002349 Supply & errection of 8.0 Mtr galvanized Octagonal pole ,continuosly tapered,single piece,3mm thick,The face to face dimension is 130mm at bottom and 70mm at top dia.base plate.size is 200 x 200 x16 mm thick The pole should be manufactured from special steel plate suitable for lighting Arrangement System ,Galvanized Founation bolt specification of bolt length 600mm circle dia 200mm bolt size 20mm,Template size is 200mm PCD,thickness 3mm with 10/4 Bakelite Cover,63 Amp 4 way Stud Connector-01No,10 Amp SPMCB-01 No,MCB Channel-01 No,Mudguard Nut,Bolt & washer-06 Nos,Aluminium Socket-08 Nos.(make-Bajaj/havells/RR-ISPAT) Ground Floor 641 40002353 Supply and fixing of 1mtr. Long Galvanized deocartive single arm welded with top canopy at an angle of 120 degree with the pole.The outer dia of arms are 46mm,4 nutbolts suitable for 70mm Top. Ground Floor 642 40002355 Supply and fixing of 1mtr. Long Galvanized deocartive double arm welded with top canopy at an angle of 120 degree with the pole.The outer dia of arms are 46mm,4 nutbolts suitable for 70mm Top. Ground Floor 643 40002360 Supply and fixing of 40mm dia HDPE pipe -PE 80 grade PN-6. 2.0 wall thickness Ground Floor 644 40002497 Supply of outdoor type auxillary panel board made out from 20guage thick CR Sheet duly painted with clamping arrangement to be fixed on street light pole equipped with 04 nos bus bar 03 nos indication lamp with 1 No toggle switch ,1 no timer switch , 1 No Stud type 4 way terminal I/P) 63 Amp ) 1 No 63A TPN MCB, 1 No 3 Pole Contractor 65 A, 1 No Single Pole MCB 10A, 3 Nos 16 amp TPN MCB , 3 Nos Stud type , 4 way terminal (O/P) 63A A with earthing arrangement [Make-(a)MCB /MCCB - Legrand/ Schnider/L &T/ ABB, ( b)Volt meter, Ammeter-AE/CAPPA, (d) all other acessories ISI mark] Ground Floor 645 40003041 Supply, installation, testing and commissioning of GI coil earthing including excavation of earth pit in all kinds of soil/rock filling with charcoal & salt, connections to earthing stids/ bolt of the pole complete including all accesories and connections. Ground Floor 646 40005870 Supply and laying of 25 sq.mm 3.5 core End termination for Cableof 1.1 KV grade ISI Marked Ground Floor 647 40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor 648 40008383 Supplying & installation, testing and commissioning of post top lantern of 40 watt LED luminare with all accessories and including connection etc. ( Gate light )(Make-CROMPTON(MODEL NO-LPTO-40-CDL-M (40 WATT)/PHILIPS/WIPRO MODEL NO-LP07-501-XXX-57-CL) Ground Floor 649 40008405 Supply & fixing of 90 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 having LM 79 LM 80 tested including bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire with all accessories . (Make- CROMPTON(MODEL NO-TRP-412-90-57-SL-LM-NSG)/PHILIPS(MODEL NO-BRP033 LED90S 90W 9000LM)/WIPRO(MODEL NO-LR08-102-XXX-57-XX ) Ground Floor 650 40009686 Supply & Fixing of 2 core 6 sqmm Cable end termination Ground Floor 651 40010339 Supply, delivery, errection, testing & commissioning of 20 Meter , 20 sided polygonal hot dip galvanized high mast suitable for wind velocity of 250 KM/HR wind speed or more. The high mast must be supplied in two sections .The top dia and bottom dia of high mast should be 150 mm and 610 mm respectively . The thickness of top and bottom section should be 5 mm and 6 mm respectively . It shall include all accessories like head frame, Two points suspension system with steel wire rope of 6 mm dia, double drum winch ,galvanized lantern carriage with 8 nos. 300 wt LED flood light fitting having die cast aluminium controlgear box complete with ignitor & capacitor. The high mast to be supplied along with LED aviation obstruction light complete with all accessories, lightening final, integral power tool ,1.5 HP motor, EPR trailing cable installed inside the base compartment. 12 nos. 1200mm length foundation bolts for foundation. .outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP conta ctor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals. The scope of work also includes to construct RCC foundation , Erection of high mast, installation of feeder pillar, 2 nos. earthing with 2.5 mtr long 40 mm dia GI earth electrode. . The high mast to be supplied along with double drum winch . Wind tunnel report of high mast shaft should confirm the force coefficient and the mast must be suitable for 250 Km/HR wind speed or more. The entire high mast lighting system should be warrantied for a period of 2 years from the date of handing over . (Make- of Luminaries- Crompton Greaves/ Philips / Wipro )(Make of mast-RR ispat/Bajaj Ground Floor 652 MIS-INE-CCTV 653 40002360 Supply and fixing of 40mm dia HDPE pipe -PE 80 grade PN-6. 2.0 wall thickness Ground Floor 654 40003368 Supply,Installation,Testing and Commissioning of RJ 45/DC Connector as per theTechnical specification and direction of EIC. Ground Floor 655 40008495 Supply of 6U wall mounted rack including all accessories and connection(make-D-link(Model no-NWR-6U-5545-GR)/MOLEX/DIGISOL) Ground Floor 656 40008498 SUPPLY OF 9U WALL MOUNTED RACK INCLUDING ALL ACCESSORIES AND CONNECTION(MAKE-D-LINK(MODEL NO-NWR-9U-5545-GR)/MOLEX/DIGISOL) Ground Floor 657 40010307 Supply , Installation, testing , commissioning of 4MP IR Network Bullet Camera: (1/3 4MP PS CMOS Image Sensor,Max. 4MP (2560 × 1440) @25/30 30fps,IR Range of 30 Mtrs, Instastream, H.265 and Smart H.264+ dual-stream encoding,DWDR, Day/Night (ICR), 3D-DNR, IP67, PoE Support) Make - CP Plus/ Prama Ground Floor 658 40010309 Supply , Installation, testing , commissioning of 4MP IR Network Dome Camera: (1/3 4MP PS CMOS Image Sensor,Max. 4MP (2560 × 1440) @25/30 30fps,IR Range of 30 Mtrs, Instastream, H.265 and Smart H.264+ dual-stream encoding,DWDR, Day/Night (ICR), 3D-DNR, IP67, PoE Support) Make - CP Plus/ Prama Ground Floor 659 40010313 4MP WDR 32x IR Network PTZ Camera: 1/2.8 2MP CMOS Image sensor (0.9071 centimeters), Max. 50/60fps@4MP, Powerful 32x Optical zoom and 16x Digital zoom, WDR(120dB), 2D/3D-DNR, Day/Night (ICR), EIS, Electronic Defog, ROI, AGC,AWB, BLC, HLC, IR Range of 150 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Support Face Detection, Make - CP Plus/ Prama Ground Floor 660 40010317 Supply , Installation, testing , commissioning of 24 Port Gigabit Ethernet PoE Smart Switch SFP port (192wt)2 . Make-Netgear/Junip er/Aruba Ground Floor 661 40010327 Supply , laying of Cat 6 Cable into PVC Pipe with casing Capping accessories CAT6 UTP Cable with LSZH Roll (305 Mtr) Make- D-link/Digisol Ground Floor 662 40010331 Supply , Installation of PVC IP55 Junction Box Ground Floor 663 40010401 Supply , Installation, testing , commissioning of 32Ch. 4K Network Video Recorder(Instastream/H.265/Smart H.264+/H.264/MJPEG codec decoding, Support 4 SATA HDDs up to 10TB Each,Support Multi-brand network cameras) Make - CP Plus/ Prama Ground Floor 664 40010403 Supply , Installation, testing , commissioning of 8 Port Giga Eth Unmanaged PoE Switch with 6KV surge protection , 150 Watt . Make- Netgear/Juniper/Aruba Ground Floor 665 40010405 Supply , Installation, testing , commissioning of 4-Port Gigabit Ethernet PoE Unmanaged Switch . Make-Netgear/Juniper/Aruba Ground Floor 666 40010407 Supply , Installation, Testing of 8 TB Surveillance HDD, Make- SEGATE/WD Ground Floor 667 40010408 Supply , Installation, Testing of HD Display LED 43 Inches or Higher Make - Samsung /LG Ground Floor 668 40010410 Supply , laying of Solid Cat 6 Outdoor Armed (ECCS Tape) Cable Make- D-link/Digisol Ground Floor 669 40010412 Supply , Installation, testing , commissioning of 1KVA Online UPS with Battery with 30 Mins Backup Make-Numeric/APC/Microtek Ground Floor 670 MIS-INE-DG SET 671 40001036 Supply and laying of 35 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 672 40010576 Design, supply, erection, testing and commissioning of 25 KVA silent type DG set(Only for light, fan , computer & 1 no Acquaguard point) with AMF, 440 V three phase 1500 RPM ,50HZ ,3 Cylinder with 4 nos earthing, 63 AMP 4 POLE CHANGE OVER ,ms pipe exhaust system, residual silencer, thermal logging and cladding of exhaust pipe complete , D.G. Plinth & Shed as per specification as required and as per direction of engineer-in-charge. Make- Mahindra Powerol Ltd/Cumins . Ground Floor 673 MIS-INE-Driver Res 674 40000946 Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 675 40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 676 40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 677 40000973 Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 678 40000976 Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 679 40000979 Recessed wiring to Security Light Point ( MODULAR) (4X24WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 680 40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 681 40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 682 40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor 683 40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK) Ground Floor 684 40001012 Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.10)(Make of PVC pipe-AKG/NORPACK) Ground Floor 685 40001042 Supply and laying of 70 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 686 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 687 40001129 Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor 688 40001132 Supplying and fixing of 8X6 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam) Ground Floor 689 40001135 Supplying and fixing of 8X10 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam) Ground Floor 690 40001141 Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421)(Make-switch/Socke t-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 691 40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 692 40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 693 40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 694 40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 695 40001172 Supply of U-type fan hook(Make-TATA) Ground Floor 696 40001193 Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells) Ground Floor 697 40001234 supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 698 40001876 Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion(Make-Legrand/wipro/Anchor-Panasonic) Ground Floor 699 40001879 Recessed wiring in 1X1.5sqmm (For inverter)/DG wiring )FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK) Ground Floor 700 40002095 Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 701 40008126 Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR) Ground Floor 702 40008142 Supply and fixing of 6 way mcb Box ( 8+18)(BDB) with I/C- 32 AMP 4PMCB & O/G-25AMP DP RCCB (100MA)-3 NOS&10 AMP SP MCB -12NOS with sheet steel encloser ,distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection ,phosphate and power painted including earthing etc as required.Make-MCB-(Legrand/L &T/ABB/SCHNIDER) Ground Floor 703 40008158 Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO) Ground Floor 704 40008393 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001) Ground Floor 705 40008397 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4/ WIPRO(MODEL NO-LL20-221-XXX-65NE3) Ground Floor 706 40008399 Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-415-25-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP029 LED25S 25W 2500LM)/ WIPRO) Ground Floor 707 40008405 Supply & fixing of 90 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 having LM 79 LM 80 tested including bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire with all accessories . (Make- CROMPTON(MODEL NO-TRP-412-90-57-SL-LM-NSG)/PHILIPS(MODEL NO-BRP033 LED90S 90W 9000LM)/WIPRO(MODEL NO-LR08-102-XXX-57-XX ) Ground Floor 708 40010369 Supply & laying of 75mm Dia HDPE pipe PN - 6 PN - 80 required for cable laying. Make - Magunm, Supreme, Sudhakar. Ground Floor 709 40010399 Main Distribution Board -Incoming power Distribution panel/ board suitable for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes, gasket, powder coated, top & bottom terminals and properly painted with anticorrosive primer and paints, comprising the following: [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC(b)-Voltmeter, Ammeter-AE/CAPPA (d) all other acessories ISI mark] Incoming- 1 No 200 Amp FP MCCB [35 kA] Busbar : 4 Nos 400A, 500V Electrolytic copper strips Outgoing - 2 nos 125Amp 4PMCCB with stud connector (36 KA) ,3 nos 63 A FPMCB with Stud connector,2 nos 40 A FPMCB with Stud connector,3 nos 63 A DPMCB with Stut connector Instrument - 03 Nos. Multi-function meters showing voltage, current, pf, frequency, MD and THD with required 500/5A CTs 03 Nos : LED type phase indicating lamps with control fuses,Door gaskets ,Door Hinges,Door locks,Wiring with socketing Ground Floor 710 MIS-INE-EV CHARGER 711 40001039 Supply and laying of 50 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 712 40001045 Supply and laying of 95 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 713 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 714 40001367 Supply and laying of 16 sq.mm 4 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) Ground Floor 715 40002095 Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 716 40002152 Supply and fixing of 95 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade end termination Ground Floor 717 40002519 Supply & Fixing of 4 core 16 sqmm Cable end termination(Brass comression) Ground Floor 718 40002745 Supply and laying of 50 sq.mm 3.5 core End termination for Cableof 1.1 KV grade ISI Marked(Brass compression) Ground Floor 719 40003522 Supply and installation of HDPE pipe inspection chambers with die cast lid Ground Floor 720 40006311 Main Distribution Board-Incoming power Distribution Panel/board suitable for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes,gasket,powder coated,top & bottom terminals and properly painted with anticorrosive primer and paints,comprising the following [Make-(a)MCB/MCB Box-LEGRAND/ L&T/ ABB/ SCHNIDER (b) meter,Ammeter-AE/CAPPA(c)all other acessories ISI mark] Main incoming- 125 amp. TPNMCCB [25 ka] - 01 set 125 amp. 415 volt cut out - 03 nos. without meter space out going- 63 amp. TPNMCB [10 ka] - 03 nos 125 amp , 25 / 3 mm. copper bus bar - 04 nos indicating lamp and controlling switch - 03 set for 63 amp. tpnmcb instruments 0 – 100 amp. ammeter with selector switch - 01 set 100 / 5 amp. ct - 01 set 0 – 500 volt. voltmeter with selector switch - 01 set indicating lamp with controlling switch - 01 set size – 900 x 900 x 200 mm Ground Floor 721 40006385 Main Distribution Board -Incoming power Distribution panel/ board suitable for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes, gasket, powder coated, top & bottom terminals and properly painted with anticorrosive primer and paints, comprising the following: [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC(b)-Voltmeter, Ammeter-AE/CAPPA (d) all other acessories ISI mark] Incoming- 1 No 200 Amp FP MCCB [35 kA] Busbar : 4 Nos 400A, 500V Electrolytic copper strips Outgoing - 3 nos 125Amp 4PMCCB Busbar : 4 Nos 200A, 500V Electrolytic copper strips 125 Amp FP Change Over ,Bus bar-200A Cupper Busbar ,Instrument-Multifunction meter,Indicator-1 set 3 Nos 63Amp 4PMCCB Instrument - 03 Nos. Multi-function meters showing voltage, current, pf, frequency, MD and THD with required 500/5A CTs 03 Nos : LED type phase indicating lamps with control fuses Ground Floor 722 40007703 Supply and fixing of Main Panel board -I/C. 100 A 4P on load change over switch-1 no, 100 Amp four pole MCCB with stud connector (36 KA) -1 No, Bus bar - 4Nos 250 Amp,500 V copper strip , drum insulator for bus bar - 8 Nos & Bus bar sleeving -1 Job , O/G-63 Amp 4P MCB with Stud connector -2 Nos ,40 Amp FPMCB stut connector-2 Nos,63 A DPMCB with Stut connector-2 nos,32 A DPMCB with Stut connector-4 Nos with sheet metal powder coating and door gasket ,door hinges,door locks ,wiring and socketing [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)-Voltmeter,Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK] Ground Floor 723 40010369 Supply & laying of 75mm Dia HDPE pipe PN - 6 PN - 80 required for cable laying. Make - Magunm, Supreme, Sudhakar. Ground Floor 724 40010415 Design,Supply ,erection,testing and commissioning of 10 KW- 3 x 3.3 KW AC E-Rickshaw charger having following specification Input Voltage 415 VAC, 3 ph 5wire(L1, L2, L3, N & PE) Input Frequency 50 Hz Number of Outputs- 3 Output 1 Rating- Each outlet 230VAC, Max 15A (MAKE- Anchor Panasonic/Siemens) Ground Floor 725 MIS-INE-FAST AID K 726 40007577 Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. Ground Floor 727 MIS-INE-FIRE FIGHT 728 40008024 Providing and fixing Carbon-di-oxide fire extinguishers. Capacity 4.5 kg. ISI Marked.(Make -Fire shield/Kanex/Safex ) Ground Floor 729 40008026 Providing and fixing stored pressure portable (powder type) ABC - 6.0 kg fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug(Make -Fire shield/Kanex/Safex .) Ground Floor 730 40008033 Providing and fixing of 4kg clean agent type fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug (Make -Fire shield/Kanex/Safex .) Ground Floor 731 40008073 Supply and fixing of wall mounting type Auto glow signages of different type like, fire exit with one side arrow /do not use lift in case of fire/Emergency Exit/Staircase Indicating Arrow etc . Sizes :-300x150mm . type .(Make-Prolite autoglow) Ground Floor 732 40008075 Supply and fixing of Location & Map Auto glow Signages . Sizes900x1200mm . Ground Floor 733 MIS-INE-LIGHTING P 734 40002086 Air-Terminal Supply, Installation, Testing & Commissioning of Early Streamer Emission (ESE-30))type Lightning Air Terminal. Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5″ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity of that area. Protection Radius :- 48 Mtr Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 735 40002089 Lightning Strike Counter Supply, Installation, Testing & Commissioning of non-electronic & non-resettable (Not require any external power supply) type lightning strike counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(6/7 digit) Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Engineer-in-Charge. Ground Floor 736 40002095 Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 737 40002098 Supply, connection &Testing of sub earthing with 16 Sq.mm single core multi stranded copper flexible wire from surge protection device (SPD) panel to earth electrode & Main panel board to SPD panel including all accessories, cable socketing and connections. Make :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge Ground Floor 738 40002101 Supply, Installation, Testing & Commissioning of indoor type wall mounted Surge protection device (SPD) panel made of 2 mm thick CRCA sheet, dust and vermin proof duly powder coated having the following arrangement & complete factory wired by 16 Sq.mm single core multi stranded copper flexible wire. [A] Type 1+2 AC Surge Protection Device (SPD) (TP+N) (50 KA) - 01 Set [B] 63 Amp. HRC fuse with link – 03 Nos [C] 100 Amp. 4 pole stud connector – 01 No Make of SPD & HRC Fuse :- HAVELLS / L&T / LEGRAND Make of Wire :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Ground Floor 739 40002720 Supply and laying of 70sqmm single core FR PVC insulated unseathed copper conductor for voltage grade 1100 volt as per IS-694 in sur face/underground as required(sl no-5.5.2)(Make-KEI/FINOLEX/HAVELLS) Ground Floor 740 MIS-INE-ONGRID SOL 741 40003442 Supply,Installation,Testing & Commissioing of Net Meter in Consultation with Distribution utility. Ground Floor 742 40011901 Design,Supply,Installation,Testing & Commissioing of Grid Connected Roof top solar PV System(Through net metering)(Make-Solar PV Panel(VIKRAM/WARREE/TATA POWER SOLAR SYSTEM/PANASONIC SOLAR) ,Solar-P.C.U-LUMINOUS/STATCON/MICROTEK/SU-KAM POWER SYSTEM,Solar Battery-EXIDE/OKAYA/LUMNOUS,DC and AC distribution-MCB-Legrand/L &T,HRC fuse-L&T/ABB,Copper cable-Finolex/Havells/Polycab) Ground Floor 743 MIS-INE-PA SYSTEM 744 40001708 Wiring to Loudspeaker with 2x1.5 sqmm stranded copper conductor unarmoured cable for loud speakers clamped with PVC pipe saddles,base etc.on ceiling/wall complete including termination,testing etc as required (Make-Finolex/Anchor/Havells/V-guard) Ground Floor 745 40001709 Installation,testing,commissioning charges of audio system. Ground Floor 746 40004559 Supplying and fixing of 25 mm dia conduit of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.( Sudhakar / AKG / BEC/ANCHOR) Ground Floor 747 40008481 Supply of wall mounted speaker make- Ahuja (ASX-312bt) including all accessories. Ground Floor 748 40008483 Supply of wireless speaker Microphone Make-Ahuja(AWM 700UH)including all accessories Ground Floor 749 40008487 Supply of Audio amplifier Make-Ahuja(SSA-250DP) including all accessories Ground Floor 750 40010436 Supply of 30 Watts Outdoor Horn Speaker ( Make- Ahuja/ Sonodyne) Ground Floor 751 40010439 Supply of ahuja Two Way Counter Communication System (Make-ahuja (CCS-2300 ) Ground Floor 752 MIS-INE-SECURITY R 753 40000946 Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 754 40000976 Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 755 40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 756 40000985 Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 757 40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor 758 40001024 Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI) Ground Floor 759 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 760 40001129 Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor 761 40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 762 40001237 Supply and fixing of 4 way , single Door MCB Box with 1 No 32 Amp. DP MCB & 2 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.,2.7, )Make-MCB-(Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC) Ground Floor 763 40008124 Supply & fixing of 400mm (16) wall mounted fan with complete accessories[brown/white].including hanging and connections [MAKE- USHA MODEL-MIST AIR DUOS/ CROMPTON MODEL-TROPEDO HI SPEED//HAVELLS/V-GURAD MODEL-PETAL WF 17/ANCHOR) Ground Floor 764 40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor 765 40008393 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001) Ground Floor 766 40008399 Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-415-25-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP029 LED25S 25W 2500LM)/ WIPRO) Ground Floor 767 MIS-INE-SHOP 768 40000946 Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 769 40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 770 40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 771 40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 772 40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 773 40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor 774 40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK) Ground Floor 775 40001024 Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI) Ground Floor 776 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 777 40001129 Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor 778 40001135 Supplying and fixing of 8X10 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam) Ground Floor 779 40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 780 40001172 Supply of U-type fan hook(Make-TATA) Ground Floor 781 40001187 Supply and fixing of 8 way , Double Door MCB Box with 1 No 32 Amp. DP MCB & 6 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )Make-MCB-(Legrand/L&T/ABB/SCHNIDER) Ground Floor 782 40001193 Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells) Ground Floor 783 40001234 supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 784 40002179 Recessed wiring to Surface Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection .( Make of wire Finolex / L &T / Anchor / Havells/ V guard)Make-switch /-Legrand /Wipro /Anchor /havells /Panasonic) Ground Floor 785 40008158 Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO) Ground Floor 786 40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor 787 40008393 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001) Ground Floor 788 40008397 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4/ WIPRO(MODEL NO-LL20-221-XXX-65NE3) Ground Floor 789 40008585 Supply and fixing of surface mounted led 18 w square/round light with powder coated finished in white housing 1with lamp , choke, connecting wire, and all accessories and connections .(Make- CROMPTON(MODEL NO-LCDSPLN-R-18-CDL/LCDSPLN-S-R-18-CDL)/WIPRO(MODEL N O-LD80-171-XXX-60-SM/PHILIPS(MODEL NO-20W Rd Metal FullGlow LED Surface ) Ground Floor 790 MIS-INE-VIDEO WALL 791 40010417 LED Display Board 126 LX63 H/10LX63H/80LX63HP outdoor 6 pixel density 160000 dots/sqm module resolution128x64 dots frame frequency 60Hz single LED unit pixel ,brightness 800-1000cd/sqm,gray scale up to 16bit /2.81 billion,optimum viewing angle 140x120,input voltage 220V AC ,operating tempreature 200C to 500C,Cabinet size 960mmx960mm die cast,english/odia/any language for text,video,image,outdoor active LED video fixed on unipole structure with ACB box with supply and installation.Thickness of the screen>120mm wall(BIS certified module)LED:NATION STAR SMP. Ground Floor 792 40010419 Novastar TB 40 processor with 4G module(BIS certified module),Novastar IND 528 receiving card,cloud based software inbuilt,LAN/Cloud data entry system having multiscreen playback synchronization mechanism (Make-Novastar TB 40) Ground Floor 793 40010423 Fixing of frame unipole structure 106x63 with ACP box for supporting LED sign board 40x40x3 mmsq SS 304 grade pipe and top plate for pole 580x500x12 mm with base plate 450x450x20mm and single pole size 275mm diax5x3000mm working platfrom made by 25x25x3 mm SS-304 grade square pipe panel size 768x768mm of ACP work(Make-Ahuja 100 watt speaker SS-304 JINDAL/NIPPON STEEL of premium quality. Ground Floor 794 40010428 LED Display Board 12.2 length X 4.2height.,10.6 length X 4.2height. Indoor P 2.5 pixel, density 160000 dots/sqm, module resolution 128x64 dots, module dimension 320 x160x15 mm frame frequency 60hz, single LED unit pixel, brightness 800-1000cd/sqm, gray scale up to 16bit/2.81 billion, optimum viewing angle 140x120, input voltage 220V AC, operating temperature 20°C to 50°C, cabinate size 320mmX160mm magnetic module, english/odiya/ any language for text, video, image, Indoor Active LED Video fixed on wall mounting with steel structure supply and installation Thickness of the screen>60mm Wall. (BIS certified module) LED: NATION STAR SMP. Ground Floor 795 MIS-INE-WORK SHOP 796 40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 797 40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 798 40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor 799 40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor 800 40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK) Ground Floor 801 40001012 Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.10)(Make of PVC pipe-AKG/NORPACK) Ground Floor 802 40001033 Supply and laying of 25 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/Polycab/KEI) Ground Floor 803 40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor 804 40001129 Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor 805 40001132 Supplying and fixing of 8X6 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam) Ground Floor 806 40001135 Supplying and fixing of 8X10 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam) Ground Floor 807 40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 808 40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 809 40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 810 40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 811 40001166 Supply and fixing of 63 AMP 4P MCB-1NO,63 AMP,415 V CUTOUT-3 NOS WITH COPPER BUS BAR & INDICATOR ETC including all accessories and connections . [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK] Ground Floor 812 40001172 Supply of U-type fan hook(Make-TATA) Ground Floor 813 40001193 Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells) Ground Floor 814 40001228 Supply & fixing of 45 W LED STREET LIGHT FITTING on wall with , G.I. Bracket, Clamp & Nut Bolt connecting wire all accessories refer to catalouge No- MAKE- CROMPTON, CODE-LSTO-45-CDL /MAKE-PHILIPS, MODEL-GREEN LINE , CODE-BRP320 / MAKE-HPL, CODE-HPLLEDST4060S & HPLLEDSL4560S including fixing and connections as per instruction of Electrical Engineer-in-charge. Ground Floor 815 40001234 supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor 816 40001653 Recessed wiring to Security Light Point (1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard/HPL) Ground Floor 817 40002173 Point wiring for Instrument Point(modular) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 2 nos of 15/16 Amp, 250 V modular type switch & socket ,& 2 nos 5 amp modular type switch & socket phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard/HPL) Ground Floor 818 40002868 Supply and fixing of 4 way , single Door MCB Box with 1 No 63 Amp. 4P Isolator with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.,2.7, ) Ground Floor 819 40008158 Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO) Ground Floor 820 40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor 821 40008397 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4/ WIPRO(MODEL NO-LL20-221-XXX-65NE3) Ground Floor 822 MIS-IPH-Drivers R 823 10000314 Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3- 2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification.Porcelin 23 inch LWC(ORISSA Pan) Ground Floor 824 10001056 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 mtr. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 20 mm outer dia CPVC pipes. Ground Floor 825 10001058 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 25 mm outer dia CPVC pipes. Ground Floor 826 10001060 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 40 mm outer dia CPVC pipes. Ground Floor 827 10001064 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method; water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid for separately). 110mm dia. SWR pipe of Single Socket Push fit of class-3 (6Kg/Sq.cm). Make:- ORIPLAST/SUPREME/FINOLEX. 110mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor 828 10001066 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method with water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid separately). 160mm dia. rigid UPVC SWR pipe Class- 3 (6Kg/Sq.cm). Make: ORIPLAST/SUPREME/FINOLEX. 160mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor 829 10001068 Providing and fixing on wall face PVC 110 mm dia. offset SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. offset PVC SWR type. Ground Floor 830 10001070 Providing and fixing on wall face 110mm dia. single junction with door PVC SWR type moulded fittings, accessories for Rigid UPVC SWR pipes conforming to IS : 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion . Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Single Junction with door PVC SWR type. Ground Floor 831 10001072 Providing and fixing on wall face 110mm dia. plain bend PVC SWR type moulded fittings / accessories for Rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Plain Bend PVC SWR type. Ground Floor 832 10001074 Providing and fixing on wall face 110mm dia. bend with door PVC SWR type moulded fittings / accessories for rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Bend with door PVC SWR type. Ground Floor 833 10001076 Providing and fixing on wall face 110 mm dia. cowel PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. cowel PVC SWR type. Ground Floor 834 10001088 Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall. Ground Floor 835 10001094 Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm. Ground Floor 836 10001098 Fixing floor traps of the following nominal diameter of outlet of self cleaning design with serewed down or hinged grating with or without vent arm complete includingcost of cutting and making good the walls and floors all complete as per specification. 110mm INLET & OUTLET FLOOR TRAP.make: ORIPLAST/SUPREME/FINOLEX 110mm Dia Inlet & Outlet floor trap PVC SWR type. Ground Floor 837 10001100 Providing and fixing EWC Commode floor mount(S/P trap) conforming to IS 2556: Part 3- 2004 duly fixed to head less socket caps/wall plugs and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per specification without cistern - Long pattern size 575x345x390mm. Make: Hindware POPULAR (CAT NO-20044 S-TRAP-28.5/P-TRAP-18.0)/Parryware ELITE (P-TRAP-CO278/S-TRAP-CO297) White Vitreous China Wash Down Water Closet (EWC). Ground Floor 838 10001116 Providing and Fixing PVC LOW LEVEL CYSTERN conforming to IS 2556 : Part 3- 2004 SIZE 415X130X305mm.Make: Hindware SUPERB (CAT NO-50 8829)/Parryware SLIMLINE ECONOMY (E-8090).White Vitreous china 10 litre (full flush) capacity manually controlled low level flushing cistern with all fittings and fixtures. Ground Floor 839 10001122 Providing and fixing of Standing urinal including connecting the urinal with 32mm dia. PVC waste pipe by means of white lead mixed with chopped hemp,15mm dia. PVC Reinforced heavy duty connection pipe etc. all complete as per specification. (White vitreous china clay half stall urinal flat back size-355X345X535 mm. Make: JAQUAR(URS-WHT-13261). Standing Urinal 355x345x535mm. Ground Floor 840 10001124 Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor 841 10001126 Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor 842 10001130 Providing and fixing of 15mm dia. CP Screw-down short body Bib Cocks (Taps) polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Headand high quality). Make: JAQUAR(CON-047KN-)/ KOHLER (K-27490IN-CP). 15mm diameter Short body bib cock. Ground Floor 843 10001132 Providing and fixing of 15mm dia. CP Screw-down two way Bib Cocks (Taps)polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux headand high quality). Make: JAQUAR( CON-041KN)/ KOHLER (K-25432IN-4-CP). 15mm dia. Two-way Short body bib cock. Ground Floor 844 10001134 Providing and fixing of 15mm CP dia. Screw-down long body Bib Cocks (Taps) polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Headand high quality). Make: JAQUAR( CON-107KN)/ KOHLER (K-27490IN-CP) 15mm dia. Long body bib cock. Ground Floor 845 10001136 Providing and fixing of 15mm dia. CP Screw-down angle Stop Cocks with flange of the following nominal sizes as per specification complete. (Deluxe Head and high quality). Make: JAQUAR (CON-059KN))/ KOHLER (K-11568IN-7B-CP). 15mm diameter Angle Stop Cock. Ground Floor 846 10001138 Providing and fixing of Screw-down 15 mm CP concealed Stop Cock with fitting sleeve, operating lever and adjustable wall flange and concealed body conforming to of the following nominal sizes as per specification complete. (Deluxe Headand high quality). Make: JAQUAR-(CON-083FTK+ALD-083FT). 15mm diameter Concealed Stop Cock. Ground Floor 847 10001140 Providing and fixing of 15mm dia. CP overhead shower rose 100mm round with rubit cleaning system including polishing all complete as per specification.(Deluxe Head and Heavy quality). Make: JAQUAR (OHS-1989)/ KOHLER (K-163561N-A-CP). 100 mm diameter / 15 – 20 mm width shower rose. Ground Floor 848 10001142 Providing and fixing of 15mm dia. CP shower arm 160mm long light body round shape for wall mounted with flange. including polishing all complete as per specification. (Deluxe Head and Heavy quality). Make: JAQUAR (SHA -477)/ KOHLER (K-99054IN-CP). 15 mm x 160 mm long size CP shower arm. Ground Floor 849 10001146 Providing and fixing of health faucet with 1.2m long PVC tube and wall hook. Make: JAQUAR (ALD-563) including all complete as per specification. 1.2m long PVC tube CP health Faucet. Ground Floor 850 10001148 Providing and fixing Stainless Steel soap dish holder fixed to head less socket caps, wall plugs with CP brass screws as per specification. Make: JAQUAR (ACN-1131N))/KOHLER (K-10712D-CP). Stainless Steel Soap Dish Holder. Ground Floor 851 10001150 Providing and fixing of 600x120 mm glass Shelf with anodised aluminium angle frame with chromium plated brassbrackets and guard rails of required size complete, fixed to head less socket caps, wall plugs with chromium plated brass screws as per specification. Size 600x120 mm glass shelf. Make: AQUAR-(ACN-1171N)/ KOHLER(K5636IN-CP). 600mmX120mm Glass Self. Ground Floor 852 10001152 Providing and fixing standard sized stainless steel towel rail of 600mm long complete with Chromium Plated brass brackets; fixed to head less socket caps, wall plugs with Chromium Plated brass screws, complete as per specification. (Make: JAQUAR (ACN-1111SM)/ KOHLER (K-5630IN-CP),(Heavy quality). 25 x 600 mm long SS Towel Rail. Ground Floor 853 10001154 Providing and fixing standard sized stainless steel towel ring with round flange complete with Chromium Plated brass brackets; fixed to head less socket caps/wall plugs with Chromium Plated brass screws, complete as per specification. Make: JAQUAR (ACN-1121BN) /KOHLER (K-5631IN-CP). SS Towel ring with round flange. Ground Floor 854 10001158 Providing and fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to head less socket caps, wall plugs and washers complete as per specification.(AR-2013,SL. NO.-3.4.26). Make: Mirror Glass (SAINT GOBIN/AIS(ASAHI)). 600mm x450mm Bevelled Edge Mirror (Heavy quality). Ground Floor 855 10001160 Providing and fixing Rotational moulded polyethylene cylindrical vertical water storage tank 3layer wall conforming to IS : 12701--1996 including cutting holes through the tank and fixing, fittings CPVC tubes and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting up to a height of 5 metres above ground level and placing the tank to the required position etc. all complete as per specification. Make: SINTEX/SUPREME/ORIPLAST. Triple Layer Cylindrical Vertical water storage tanks. Ground Floor 856 10001166 Fixing wash basins WITHOUT PEDESTALwith hole for pillar taps with 10mm dia M S rack bolt (JAQUAR MAKE) painted white including cutting holes in walls and making good the damages etc all complete, with fixing of 15mm dia pillar cock, as per specification.(Vitreous china flat back wash basin 550x400x200 mm)(CODE CNS-WHT-801 JAQUAR MAKE).Pillar cock(CON-021 JAQUAR)32mm full/half thread CP waste(ALD-705/709-JAQUAR), Rack bolt(ZPS-MST-RB03)Vitreous china flat back wash basin 550x400x200mm . Ground Floor 857 10001209 Providing and fixing curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish size H:900XW:450mm with stainless Steel brackets including cutting holes in wall and making good the damages etc. complete as per specification. Make: JAQUAR (JSE-CHR-110UC450X/110US450X). Curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish. Ground Floor 858 SIG 859 50014253 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering<(>,<)>fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel-JINDAL/NIPPON of premium quality, Signage-3M (90CM EQUILATERAL TRIANGLE)# Ground Floor 860 50014255 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (80cmX60cm Rectangular) Ground Floor 861 50014257 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60cm circular) Ground Floor 862 50014259 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (90cm circular size) Ground Floor 863 50014261 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60CmX45Cm Rectangular) Ground Floor 864 50014263 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (90 cm high octagon) Ground Floor 865 50014265 Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60X60 cm square) Ground Floor 866 50014267 Manufacturing, supplying and fixing informative retro reflective sign boards/ prismatic retro reflective information sign board made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c and screws and anchor bolts including making holes in plates, providing & fixing ACP message plate of required size. The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect to fix on the wall. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M Ground Floor 867 50014269 Manufacturing, supplying and fixing retro reflective sign boards (single side) 8’x6’ made up of 3mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 40mmx40mm along with theft resistant measures, mounted and fixed with 4 Nos. S.S. square tube of 40mmx40mm to a vertical post made up to S.S. tube of schedule 40 of 50mm dia welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 50mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. FOR 2 VERTICAL POSTS. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M Ground Floor 868 a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC) 869 APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK 870 Provision For 5 Year Repair & Maintenance (as stated in DTCN cl no.111) 1.75% 871 CESS
Contract Date: Jan 28, 2026 Contract Value : 6.54 Crore
Government Departments No of Bidders 9
Contract Date: Ref. Documents Contract Value : 13.89 Lakh
Boards / Undertakings / PSU No of Bidders 1
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 17.01 Lakh
Boards / Undertakings / PSU No of Bidders 6
Maharashtra View Result →
50.
Civil Aviation #8553625 AOC
Tender For Construction Of Apron And Taxiway At Kishangarh Airport. Sh Electrical Work.; 1 Supply of Medium Intensity Elevated type omni directional LEDTaxiway edge Light fitting (LED type) for aviation visual aids requirements complete with LEDs, optic lens, power converter,two pin secondary lead, central column assembly, breakable coupling, base plate, gaskets, bolts etc. and all other standard accessories required as per ICAO and conforming to technical specifications. 2 Supply of omni directional Inset Type Taxi way edge Light Fitting complete with shallow base, matching body made of die cast aluminium, pr-focused LED lamp and driver units suitable to work on 15 w 6.6/6.6 amps Isolating transformer with all accessories confirming to ICAO requirement complete as required. 3 Supplyof following type Bi-directional inset type High intensity Runway Edge light fitting for aviation visual aids requirements complete with shallow base of side cable entry, matching body of the fitting complete with 2 x 105 Watts, 6.6 amps pre-focused reflector halogen lamp connected heat resistant accessories, prism assembly, optical assembly, O ring seal, pressure relief test plug, hardware, Cover Gas Kit and all other standard accessories required as per ICAO and conforming to technical specifications. 4 Clear/Clear 5 Clear/Yellow 6 Supply of Single core, 06 Sqmm, 5 KV,XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specifications. 7 Supply of Single core, 16 Sqmm, 5 KV,XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent,Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specifications. 8 Supply of 2 core 4 sqmm 600 V grade, copper conductor, EPR insulated, PCP sheathed, underground secondary cable complete as specified complete as required and conforming to technical specifications. 9 Supply of following type, 5 KV grade, 50 Hz, series Isolating Transformer encapsulated in polyester resin, finally moulded in neoprene type rubber with primary and secondary connectors etc and all other standard accessories required as per ICAO and conforming to technical specifications. 10 15 W, 6.6/6.6 Amps. 11 45 W, 6.6/6.6 Amps. 12 100 W, 6.6/6.6 Amps. 13 200 W, 6.6/6.6 Amps. 14 Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with5 KV grade PVC insulated and PVC sheathed single core 6 sqmm copper conductor cable as etc complete as required and conforming to technical specifications. 15 Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with5 KV grade PVC insulated and PVC sheathed single core 16 sqmm copper conductor cable as etc complete as required and conforming to technical specifications. 16 Supply of 1.1 KV grade plug & receptacle (Essena Connector) of type II class B connector & suitable for field attachment with1.1 KV grade PVC insulated and PVC sheathed 2 core 4 sqmm copper conductor cable etc complete as required and conforming to technical specifications. 17 Supply, installation, testing and commissioning offollowing ratingIndoor type air cooled constant current regulator of microprocessor controlled, thyristor type suitable for operation on 230 Volts + 10%, 50 Hz input AC supply with 5 steps variation of current output, suitable for local and remote control operation with suitable control supply and able to communicate with PC or PLC controlled system, withoutput current indicated on multifunction digital display, overcurrent, over voltage, open circuit and earth fault protection and earthleakage meter, positive back indication equipments, hours run counter,complete as required, confirming to ICAO requirements and as per technical specifications. 18 4.0 KW 19 7.5 KW 20 Design, Manufacturing, Supply, installation, connection, testing and commissioning of illuminated taxiway/ runway guidance signages of various sizes made of anodized 2 mm (nominal) thick extruded aluminum profile frame with suitable stiffening supports for structural rigidity, 1.5 mm thick aluminum back cover, 4 mm thick poly carbonate sheet with glare free face, supporting legs, breakable coupling etc. The letters and symbols shall be internally pasted/ screen printed with required coloring. The sign boards shall be uniformly internally illuminated with required number of LEDs strips to achieve required illumination level, alongwith drivers, internal control circuit, automatic changeover to function on both main & standby (runway/ taxiway) circuits etcand shall operate without any flickering when operated on input source of 2.8 Amps. to 6.6 amps. series current. The suitable arrangement shall be made for water tightness and locking arrangement. The signages shall be installed on 1:2:4 grade cement concrete of size 400x400x500 mm for each leg and total base of 150 mm thick for the distance of 1.5 mtr. all around the board including installation of isolating transformer, crimping/ jointing of plug & receptacles, laying of secondary leads, connections, earthing etc. complete as required. The taxiway guidance signages shall be as per ICAO and confirming to technical specifications. (legends shall be as approved by Engineer‐in‐charge). 21 Design, Manufacturing and Supply of illuminated taxiway/ runway guidance signages of various sizes made of anodized 2 mm (nominal) thick extruded aluminum profile frame with suitable stiffening supports for structural rigidity, 1.5 mm thick aluminum back cover, 4 mm thick poly carbonate sheet with glare free face, supporting legs, breakable coupling etc. The letters and symbols shall be internally pasted/ screen printed with required coloring. The sign boards shall be uniformly internally illuminated with required number of LEDs strips to achieve required illumination level, alongwith drivers, internal control circuit, automatic changeover to function on both main & standby (runway/ taxiway) circuits etcand shall operate without any flickering when operated on input source of 2.8 Amps. to 6.6 amps. series current. The suitable arrangement shall be made for water tightness and locking arrangement. The taxiway/runway guidance signages shall be as per latestICAO guidlines and confirming to technical specifications. (legends shall be as approved by Engineer‐in‐charge). 22 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID 51mm nominal) 23 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) 24 Supply of cast iron isolating Transformer housing box, water tight round type, metal container of outside size 330 mm dia, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick , cast iron moulding suitable to receive a light fitting base plate/ cover plate on the top and underground for housing transformer, power cable and having one/two/ three nos holes as per site requirement on the periphery centre, 75 mm above bottom surface suitable to receive of 50 mm and 15mm dia GI/DWC HDPE/HDPE pipe as required. The box should have two SS earth bolts of M10x40 mm tapped inside near the hole (4 away from the hole centre) and having drain hole at the bottom suitably tapped to receive 15mm dia GI pipe and having clear opening of 220 mm at the top surface and 06 Nos. M10 tapped hole having centre to centre distance of 260mm to receive fittings/base plate and bolts, etc complete as required. 25 Installation of transformer housing boxes with a base concrete of 1:3:6 of size 630x630x100mm thick, all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cement including providing and fixing 300mm long 15mm dia B class GI pipe with check nut for drainage of water including excavation of soil and refilling, adjustment of CI boxes etc. complete as required. 26 Installation, testing and commissioning of medium intensity LED type taxiway edge light fitting on the existing transformer housing box including installation of isolating transformer, crimping/jointing of plug & receptacles, layingofsecondaryleads, connections, earthing etc. complete as required andincludes supplyofallmaterials excluding fixture, secondary lead, isolating transformer and plug & receptacles. 27 Installation, testing and commissioning of inset type runway/ taxiway edge light by core cutting in therunway/taxiway/apron pavement, fixing the shallow base with dobefil and hardener, installation of isolating transformer, crimping/jointing of plug & receptacles, layingofsecondaryleads, connections, earthing etc. complete as required andincludes supplyofallmaterials excluding fixture, secondary lead, isolating transformer and plug & receptacles. 28 Laying one number 5 KV grade Airfield lighting cable of sizesingle core6 / 16 Sqmm, 2x4 Sqmm secondary cablein the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 29 Laying of one number 5 KV grade Airfield lighting cable of size single core 6/16 Sqmmand 2x4 Sqmm secondary leadin the existing masonry duct as required. 30 Excavation of the trench in the hard rock not exceeding 1.5 metres in width, and lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated soil as directed with in a lead of 50 mtrs. 31 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 32 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 33 Providing and fixing 6 SWG dia G.I. wire on surface or in the existing / DWC/HDPE/ metal pipe for loop earthing along withcable etc complete as required. 34 Kerfs cutting with machine in taxiway/runway of PQC/bituminous surface of suitable depth and width for 1 or 2 nos secondary lead along with earth cables and laying of secondary lead and earth cable by wrappingtape i/c refilling the same by suitable sealing materialetc. complete as required and as per instruction of EIC. 35 Upgradation and integration of existing Electro System make Airifeld lighting control and monitoring system (ALCMS) for newly added taxi-C lighting facilities including taxiway edge lights, guard lights, Signages etc complete with all required upgradation/enhancement of software and hardware for the units installed in ATC and CCR hall meeting ICAO/FAA. 36 Supply of FAA certified / compliant model, Elevated, Uni-directional, Yellow, suitable for ICAOall weather operation, LED Runway Guard lights complete with Two elevated LED light fittings, driver, site programmable flash control unit ( switching device), cable lead with plug, Lense, glass, optical assembly, seal, hardware and all standard accessories, ready for site installation along with breakable coupling and base plate as per site requirement etc. compatible to existing ALCMS conforming to latest ICAO / CAR requirement as per specifications complete as required. 37 Installation, testing & commissioning of elevated type Runway guard light fittings i/c installation of isolating transformer, crimping/jointing of plug & receptacles,makingconnectionsi/csupplyofallmaterials excluding fixture, plug & receptacles & isolating transformer etc. as required. 38 Dismantling of existing taxiway lights and shifted to electrical store as per direction of EIC. 39 Design, SITC of 20 Mtr High mast , GI Polygon continuously tapered in three sections suitable for wind speed as per applicable IS 875 Parts- 3, with raising lowering system comprising , head frame, luminaries carriage suitable to install min 10 luminaries in Asymmetrical arrangement as per lighting Design, double drum winch, 6mm diameter SS wire rope , trailing Cu. cable suitable current carrying capacity between top carriage and the base terminal (inside mast) including supplying & laying of required length of 1.1 KV grade of suitable size XLPE insulated PVC sheathed armoured Aluminium conductor power cable between Feeder Pillar of High Mast and Base Terminal in DWC HDPE pipe of suitable size alongwith supplying & making end termination with heavy duty Brass compression gland , with connector, intergal power tool motor, manual handle ,lightning Arrestor , junction box ,weather proof and vandal resistant door flush with the exterior surface containing a terminal plate thick backlite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations. including of followings.... 40 Supply & fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plate and common template. 41 Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and other accessories. 42 Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all other accessories.. 43 Supply & fixing of LED type single dome aviation obstruction light.-02 Nos 44 ITC of minimum 10 nos LED luminaries. 45 Supply of outdoor stand mounted feeder pillar, Installation of the feeder pillar by grouting the stand in concrete, dust and vermin proof with 2 Nos. (1No for Incoming supply and 1 No for spare) 32A TPN MCB incomer including necessary arrangement for auto/mannual and remote control/operation, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with suitable contactors and raise and lower push button, terminals for incomer 35 sqmm and outgoing 16 & 2.5 sq.mm -01 set etc. complete as required. 46 Dismantling of existing 20 Mtr Highmast and shifting at new location or storein Airport as per instruction of EIC, with the help of suitable tools and plants. 47 Installation, Testing & Commissioning of existing old highmast of 20 Mtr height at new location in the airport as per instruction of EIC etc. complete as required including of followings....(i) Erection of the high mast with the help of suitable tools and Machinery. (ii)Installation of luminaries carriage andluminaries i/c connections.(iii) Installation of existng feeder pillar by grouting the stand in 1:2:4 concrete up to the depth of 100mm and up to 0.5 mtrall around the panel. -01 set 48 Design, Fabricarication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor mounted, extendable on both sides, outdoor LT panel made out of 2 mm thick CRCA sheet duly rust inhibited, stove enameled, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 400A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction Meter, suitable for measure Volatge, Current, Energy, frequency, power factor etc.withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band MCCB ON, and OFF lamps with protection MCBs.BUS COUPLER1 Nos. 400A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication ON, and OFF lamps with protection MCBs.BUS BAR1 Set of 600A TPN Busbars of aluminium alloy.OUTGOING02 Nos. 125 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.06 Nos. 63 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 32 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.10 Sets (1 Set for each outgoing) LED type ON and OFF Indication Lamps with protection MCBs.10 Sets of Rotary operating mechanismincluding terminal extension for all the MCCBs. 49 Desing, Supplying, installation, testing and commissioning ofsection of existing LT Panel section suitable for 04 nos outgoing415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and3 mm thick for gland plated i/c. cleaning and finishing complete withpowder coating in approved shade, having 800 Amp. capacity extensible type 4- pole Aluminium alloy bus-bars (approx length-3 mtr) of high conductivity, DMC/SMC bus bar supports with suitable short circuit withstand capacity., bottom base channel of MS section of size not less than 75mm X 40mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50 mmx5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Alu. busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half i/c. providing following switchgears :-OUTGOING2 Nos. 63 A FP MCCB (Ics=Icu=30 KA) with thermal magnetic release.2 Nos. 40 A FP MCCB (Ics=Icu=30KA) with thermal magnetic release.4 Sets ( Set of 02 for each outgoing) LED type ON & OFF Indication Lamps with protection MCBs.4 Sets (set of 03 for each outgoing) LED type R,Y,B Indication Lamps with protection MCBs.Digital Multifunction meter with RS 485 port -01 no. for each outgoing.CT of suitable ratio -01Set of 03 CTs for each outgoing.4 Sets of terminal spreader for 63 A & 40 AFP MCCBs. 50 Supply of 1100 V Flexible,following Cable with bright annealed bare copper conductor,FR PVC Insulated & PVC Sheathed round Wires as per IS-694 up to date ammended. 51 10 core 2.5 Sqmm 52 4 core 2.5 Sqmm 53 Laying one number 1.1 KV grade highmast control cable of size up to 10 core2.5 Sqmm.in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 54 Supply of 500W, LED flood light with high pressure die cast Aluminium / standard alloy Housing and LEDs of approved make pasted on diecast housing and high efficiency diffuser, Driver installed on cast luminium housing and prewired upto the terminal block. It shall have luminaire efficacy of not less than 110 lm/W with constant current driver output,Operating voltage range 240V, 50Hz AC supply,CRI>70, CCT from 5700K - 6500K with PF≥0.95 andTHD<10% & surge protection of ≥10KV suitable for outdoor applications.The luminaire shall be minimum IP-66 protected, with 05 year warrenty from OEM etc. complete as required. 55 Supply of 400W, LED flood light with high pressure die cast Aluminium / standard alloy Housing and LEDs of approved make pasted on diecast housing and high efficiency diffuser, Driver installed on cast luminium housing and prewired upto the terminal block. It shall have luminaire efficacy of not less than 110 lm/W with constant current driver output,Operating voltage range 240V, 50Hz AC supply,CRI>70, CCT from 5700K - 6500K with PF≥0.95 andTHD<10% & surge protection of ≥10KV suitable for outdoor applications.The luminaire shall be minimum IP-66 protected, with 05 year warrenty from OEM etc. complete as required. 56 Supply of following size 1.1 kv grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. 57 4 Cx50 Sqmm 58 4 Cx25 Sqmm 59 Supply of 3.5C x 150 Sq.mm size 1.1 kv grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. 60 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 Core x 150 Sq.mmsize cable in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 61 Laying of one number PVC insulated and PVC sheathed/ XLPE 4 core aluminium conductor cable of 1.1 KV grade of size above 35 Sqmm and up to95 Sq. mm in the existing RCC/HUME/METAL/HDPE Pipe as required. 62 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size up to 35 sq. mm in the existing RCC/ HUME/ METAL/HDPE/DWC pipe as required. 63 Supplying and making end termination with suitable size 4 pole terminal blockand aluminium lugs for 4C X 25 sq. mm PVC insulated and PVC sheathed / XLPE, Armoured,aluminium conductor cable of 1.1 KV grade as required. 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(i).4C X 50 sq. mm 65 Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 150 Sqmm, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete as required. 66 Supply of90 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required. 67 Supply of110 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required. 68 Laying of HDPE pipe (PE- 80, PN-6) of size up to110 mm (OD) in suitable depth by trencheless horizontal directional drilling (HDD) method by deploying HDD machines with necessary arrangements complete as required as per the site requirements.(Excluding the cost of HDPE Pipe) 69 Supply and fixing of outdoor use power point having Input (16 Amp x 5 Pin = 01 Plug) and Output (16 Amp x 3 Pin = 04 Socket, 16 Amp x 5 Pin = 02 Socket)with suitable Protection MCB & RCD mounting on the angle of 40mm X 40mm X 5mm including fixing in CC (1:3:6) foundation 300mm X 300mm X 300mm, with all accessoriesetccomplete as required.Make/Model:- PowerNPack/PDB02 or equivalent. 70 Numbering of GLF fittings with letters in yellow on black back ground as per inscription approved of Engineer in charge as required.
Contract Date: Oct 04, 2025 Contract Value : 1.40 Crore
Boards / Undertakings / PSU No of Bidders 3
TenderDetail
Loading tenders