View Bid Results For Analogue Survey Meter Tenders

We found 12 Bid Results related to analogue survey meter tenders. You can find Contractor details who won analogue survey meter tenders along with contract details in Bid awards announcements section.

Filters
Stage
11
1
Tender Publishing Platform
3
9
State / UT
7
4
2
2
1
1
1
1
Contract Value
1
1
5
5
Publish Date
0
0
0
0
0
Sector
5
4
4
2
1
1
Ownership
3
7
3
2
Within keyword
Active filters:
Showing 1–1 of 12 tenders matching your filters
1.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
2.
Drinking Water Supply and Sanitation #9128337 Technical Bid
Tender For Work Of Augmentation Of Uwss Todaraisingh, District Tonk Including 5 Years O And M Under Cm Budget Announcement. - Water Supply Scheme for Augmentation of UWSS Todaraisingh, District Tonk including 05 Years O&M after 01 year Defect Liability Period under Modified Budget Announcement (2024-25) Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 2 100 mm 3 150 mm 4 200 mm 5 250 mm 6 350 mm 7 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-100PN-6 8 90 mm dia 9 110 mm dia 10 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. HDPE PE-100PN-6 11 125 mm dia 12 140 mm dia 13 160 mm dia 14 Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethyleneincluding preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge.Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface. 15 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 16 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 17 MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) 18 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 19 25.0 Sq.mm, 3.5 core 20 35.0 Sq.mm, 3.5 core 21 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 22 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 23 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M 24 200KL capacity 25 300KL capacity (2 nos) 26 Laying and Jointing PVC Pipe. Heading 27 Laying and Jointing PVC Pipe. Heading 28 Laying and Jointing PVC Pipe. Heading 29 500 KL capacity 30 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 31 100 mm 32 150 mm 33 200 mm 34 250 mm 35 350 mm 36 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 37 In All Typeof Soil 38 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: 39 Ordinary rock 40 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 41 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. (M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 42 Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coilincluding excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work, but excluding the cost of pipe line. 43 Providing, installation, testing and commissioningof Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class F insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 44 75 KW 45 Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 46 Discharge 20 to 30 LPS and head 71 to 80 M 47 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 48 50 mm 49 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 50 150 mm dia 51 200 mm dia 52 400 mm dia 53 Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuumtight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirmingtoBS-EN-1171/AWWAC-509andoffollowing specifications:Body & bonnet ofDuctile castiron ofgrade GGG40/GGG50as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202F4,Stem/spindleofSSAISI316/410Electrostaticepoxypowder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thicknessof250micronsinsideandoutside,DrilledasperIS1538.Nut-Bolt confirmingtoIS:1363andIS:1367 (Galvanisedsteel)Insertionrubberofblack EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves includingall jointing& jointingmaterial, labour,testingandcommissioningalong withpipelineasperTechnicalSpecificationsandasperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 54 100 mm dia 55 125 mm dia 56 150 mm dia 57 200 mm dia 58 250 mm dia 59 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 60 100 mm dia 61 150 mm dia 62 200 mm dia 63 250 mm dia 64 350 mm dia 65 200 mm dia 66 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR O ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel)Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 67 150 mm dia 68 Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 69 150mm dia 70 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 71 100 mm dia. 72 125 mm dia. 73 150 mm dia. 74 200 mm dia. 75 250 mm dia. 76 350 mm dia. 77 400 mm dia. 78 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint(FabricatedSteel) asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. 79 100 mm dia. 80 150 mm dia. 81 200 mm dia. 82 250 mm dia. 83 Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx. 84 Type I ( 72.3 Sqm) 85 Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 86 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 87 Providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre center to center with 0.40 metre embedded in M15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects including all material, labour. 88 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. For in-campus Valve Chambers 89 Sluice valve chamber of size1.13m x0.85m x1.225mfor pipe size-upto100mm 90 Sluice valve chamber of size1.17m x0.95m x1.37mfor pipe size-from 125-to-150mm 91 Sluice valve chamber of size1.26m x1.185m x1.76mfor pipe size-from 200-to-300mm 92 For Class-AA loading 93 Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm 94 For in-campus Valve Chambers 95 Sluice valve chamber of size1.39m x1.43m x2.125mfor pipe size-from 350-to-450mm 96 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. For Class-A loading 97 Air valve chamber of size0.9m x1m x1.71mfor air valve size-from 50 mm-to-80mm 98 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. 99 Air valve pillarfor airvalves size of 80mmdia 100 SITC ofUltrasonic Level Transmitter suitable for measuring water levelin reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %,as per detailed Technical specification, scope of work and direction of Engineer in charge. 101 Measuring range 0.0 to 6.0 mtr 102 SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 103 EFM100 mm 104 EFM 150 mm 105 Design, construction,testing and commissioning ofRapid Gravity Filter Treatment Plant including all relevant civil, electrical , mechanical ,instrumentation, automization and SCADA works, chemical building and stores along with ancillary civil works as defined in scope of work, technical specification and provisions of CPHEEO manuals for the following capacity . 106 Cost of 200 KLH 107 Add per KLH above 200 KLH and upto 500 KLH 108 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer 109 Rubble stone masonry in cement mortar. 110 Steel work in all type sections up to a height of 5 metre above plinth level (Riveted work where rivet are required to be cut shall be measured and paid separately) 111 Excluding dismembering 112 Extra for cutting rivets in built up steel sections. 113 SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. 114 37 KW 115 75KW 116 Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 46 No.DO 42 No. AI 10 No. AO 4 No. MCB 16A DP 2 No. MCB 6A DP 6 No.SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No.Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No.Panel Light with Door Switch, 7W 1 No.Control Indication Lamp for 24VDC, 220VAC 3 No.Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No.HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot 117 Cost for Basic Service Charges, Administration and Management, Running of Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 5 years after defect liability period of one year DLP (except power feeder, IEC & miscellaneous provision) for Water Supply project. 118 1st year 119 2nd year 120 3rd year 121 4th year 122 5th year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
3.
Drinking Water Supply and Sanitation #8108759 AOC
Tender For Water Supply Scheme For Augmentation Of Uwss Behror Including 05 Years O And M After 01 Year Defect Liability Period Under Cm Budget Announcement 2024 To 2025 Under Jurisdiction Of Phed Distt Kotputli Behror - 1 TUBE WELL 2 Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strataunconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and its packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. Nominal bore 200 mm dia. (PHED 2021/2.1.4) 3 Nominal bore 200 mm dia. 4 Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 5 Nominal bore 200 mm dia. 6 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 7 Add 30% extra on above item(Item No 2.3.1 to 2.3.3) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr . 8 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date offollowing sizes 150 mm dia NB (Thickness of pipe 5.0mm & mass of tube 20.13 Kg/m) 9 Supply & Fixingtube well coverofMS sheet 8mmthick attop &5mmthick 100mmwideshroudaroundtheedgesoastoformacaponthe topend of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre ofMS sheet. A25 mmsocket with end plug shall also be welded over top plate. A GI nipple having outside thread ofsize 1/2 (for installation pressure gauge) shall be provided &welded with 80mm GI nipple near top plate nipple shall be provided with end plug. (200 mm dia) 10 Providing & Lowering in tubewell ISI marked GI Pipe “B (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 50 mm dia. 11 Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. 12 9.3 KW (12.5 HP) & head above 120 mtr. 13 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes. 65 mm dia 14 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 80 mm 15 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for440 Volt AC Supply.Above 10 HP and up to 15 HP 16 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.16 sq mm size,4 core 17 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 65 mm dia 18 Supplying & installing 100mm dia mtr sealed diaphragm bourdon type pressure gauge of range of 0 to 10 Kg including all jointing materials as per specification with safety cover 19 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 20 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. 21 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 4.0 Sqmm 3 core 22 Providing & laying GI Pipe “A” (Light) class as per IS: 1239 pat 1: 2004 or amended upto date for casing pipe for submersible cable external work 40 mm dia complete in all respect. 23 RISING MAIN & DISTRIBUTION 24 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 25 HDPE PE-80 PN-10 26 90 mm HDPE 27 110 mm HDPE 28 125 mm dia 29 140 mm dia 30 160 mm HDPE 31 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 32 HDPE PE-80PN-6 33 90 mm dia 34 110 mm dia 35 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 36 HDPE PE-80PN-6 37 125 mm dia 38 140 mm dia 39 160 mm dia 40 180 mm dia 41 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7 gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar liningsuitable forpotablewaterwithrubberring (EPDM) jointsas perIS:5382-1985includingalltaxes(Centralandlocal), transportation and freight charges, inspection charges, loading/ unloadingcharges, includingcostoflabourandmaterial,specials (Tee,bendetc.)satisfactoryhydraulictesting,disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note:Providingandfixingofallrequisitespecialsasperdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 42 100 mm 43 150 mm 44 200 mm 45 250 mm 46 300 mm 47 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 48 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 49 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. (M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 50 Removing& Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)Note: If existing precast block used more than 70%, than for every 1% use above 70%, deduction of 1% in cost shall be done for every 1% use above 70%. 51 80 mm thick. 52 100 mm thick 53 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 54 Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 55 100 mm dia 56 125mm Dia 57 150 mm dia 58 200 mm dia 59 250 mm dia 60 300 mm dia 61 400 mm dia 62 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 63 100 mm dia. 64 125 mm dia. 65 150 mm dia. 66 200 mm dia. 67 250 mm dia. 68 300 mm dia. 69 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proofKinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538.Epoxy paint (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amendedup to date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.0 70 80 mm 71 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge.For Class-AA loading 72 Air valve chamber of size0.9m x1m x1.71mfor air valve size-from 50 mm-to-80mm 73 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. 74 Air valve pillarfor airvalves size of 80mmdia 75 Pumping machinery 76 Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions Note: Duty condition of required pump shall also be mentioned in BoQ. 77 Discharge 51 to 60 LPS and head 71 to 80 M 78 SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus 79 75 KW 80 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm, 3.5 core 81 Providing and laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required 82 10.0 Sq.mm 3 core flat 83 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineerin-charge. MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) 84 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type NonReturnValves(NRV) ofapprovedmakeoffollowingPressurerating& dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of followingspecifications:Body,Cover&discofGreycastironofIS:210/FG200. FacetofacedimensionsasperIS5312(part-1):2004,FlangesDrilledasper IS:1538.Epoxy (Non-Toxic&suitablefordrinkingwater)appliedonbody,cover anddiscinsideandoutside.BodyseatringofSS/CSDoorfacering-EPDM/ Neoprene (food grade quality) ,Shaft ofSS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-BoltasperIS:1363andIS:1367(galvanisedsteel),Insertion rubber of black EPDM 6mm thick. Suitable support structureas perdirections of EIC including jointing & jointing material, labour, testing and commissioning along withpipelineasperTechnicalSpecification&asperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 85 200 mm dia 86 Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - 87 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 88 h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k)Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 89 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-4 90 500 KL capacity 91 ProvidingandfixingdoubleflangedISImarkedDI ClassK-9pipesasperIS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such asduckfootbend,bend,teeetc.providingandfixingclampsatevery3mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up toandfromvalvechamberasperdirectionofEIC,TechnicalSpecificationandScopeof work. 92 400mm 93 Construction of Pump house of RCC framed structure with pump pit in RCC walls as per scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete as per direction of Engineer-in-charge. The GA, structure, electrical, sanitary,P&ID,SLDtobepreparedbythecontractorandsubmittedto department for approval for earth quake zone II. 94 Pump House with Monorail arrangement 95 Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC,600mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5.CementmortarpointingonStone masonryandcementmortarplaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 96 Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, square bars,flatsorblackpipe with holdfast andfitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 97 Pump House with operator room 98 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan)ncluding dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 99 (Depth from Av. GL to 1.5m depth) 100 Total Earth Work Quantity 101 Earth filling 102 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 103 Net qty ofEarth filling req. 104 Kharanja (soling) 105 Random rubble dry stone Kharanja (soling) under floor. 106 PCC 107 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 108 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 109 RR Masonry for Foundation 110 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 111 Cement mortar 1:6 (1 cement : 6 coarse sand) 112 Brick Work 113 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 114 Cement mortar 1:6 (1 cement : 6 coarse sand) 115 Half brick masonry 116 Half brick masonry in foundation & plinth using bricks of designation 75 Cement mortar 1:6 (1 cement : 6 coarse sand) 117 Partitian Wall 118 RCC 119 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 120 Steel fabrication 121 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) 122 Thermo-mechanically Treated bars (Conforming of relevent IS code) 123 Centering & Shuttering 124 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : 125 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 126 Plaster 20 mm (Internal plaster- in CM 1:4) 127 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 128 1:4 (1 cement : 4 fine/ coarse sand) 129 Plaster 25 mm (Externalplaster) (Cm 1:6) 130 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 131 1:6 (1 cement : 6 fine/ coarse sand) 132 Plaster 12 mm Ceiling plaster) (CM 1:4) 133 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 134 1:4 (1 cement : 4 fine/ coarse sand) For Ceiling portion 135 Flooring 136 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. 137 Size 600mm x 600mm 138 M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/park, domestic drives, paths and patios, Embankment slopes,sand stabilization Area etc.( As per table 1 of IS 15658:2006 139 Category „B‟ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 140 Skirting Dado 141 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 142 Size 800mm x 1200mm 143 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) 144 Rain water pipe 145 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 146 110 mm diameter 147 Rain water pipe fittings 148 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 149 Bend 87.5° 150 Ceiling Fan clamp 151 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete. 152 Door Frame 153 Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry : 154 Size 125 x 100mm 155 Steel Door 156 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 157 Add extra for double leaf shutters. 158 mummty door 159 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 160 Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide.Extra for providing D type pipe head as top of hand railing 161 Windows and Ventilator Shutters 162 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : 163 Windows side hung /Ventilators top or centre hung (openable) 164 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A:Decorative teak veneer One side 165 35 mm thick . 166 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete (allplaster surface ) 167 Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding. : all inner plaster surface with ceiling 168 Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:all outer plaster surface 169 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:all outer plaster surface 170 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ @ 1.45 ,1.20 and 1.45Kg per sqm. of area respectively second and fourth courses of roofing felt type 3 grade-I conformingto IS1322 (Hessian basedself finished bitumen felt) conforming to IS 1322 and sixth and final course of stone grit 6mm and down size of pea sized gravel spread at 6 cubic dm.per square metre including preparation of surface but excluding grading complete . 171 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :(In 75x75mm deep chase) 172 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth 173 Electrical Work 174 Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR PVC insulated unsheathed 1.1kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated copper earth conductor (IS:694) of approved make in double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A switch 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers , making connections, testing etc. as required. 175 Short point (up to 3 mtr.) 176 Medium point (up to 6 mtr.) 177 Long point(up to 10 mtr.) 178 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal, 2 Nos 10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure A attached with this BSR 179 Short point (up to 3 mtr.) 180 Medium point (up to 6 mtr.) 181 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 182 25 mm 183 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure A attached with this BSR 184 6 A to 32 A rating 185 P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections with lugs , testing etc. as required. 186 Double pole MCB(With B/C curve tripping Characteristics) 187 50/63 A rating 188 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board withMetal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. 189 Metal door (single phase) IK-09 and IP-43 with Metal end box 16 Way (16+2) 190 Plumbing and Sanitary work 191 P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor 192 P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.) Size 450 193 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : 194 Size 450 mm x 300 mm 195 P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 196 Fire clay glazed kitchen sink (I.S 771-1985Marked) size 600 x 450 x 250mm. 197 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 198 1000 litres capacity. 199 CPVC. Pipe fittings 200 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 201 15 mm diameter 202 20 mm diameter 203 25mm diameter 204 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge 205 Bib Cock with long thread 15 mm nominal size 206 Stop cock long thread 207 P & F Jet spray for water closet with C.P. Copper Tubeflange of approved make 208 P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. 209 Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm. 210 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. 211 700 mm Dia 10 mm thick casing pipe . 212 Cost for Basic servies charges, Administration and management, Running of Operation and maintenance and repair Including Preventive Manintenance, Cost of material required for Maintenance and repair, cost of lubricants, Consumables, Spare parts ( If the spare parts supplied to PHED are used in emergency) as per scope of work & terms & conditions of contract for 5 years after defect liability period of one year DLP (except power feeder, IEC & miscllenous provision) for Water Supply Project. 213 1st Year 214 2nd Year 215 3rd Year 216 4th Year 217 5th Year
Contract Date: Oct 14, 2025 Contract Value : 9.80 Crore
Government Departments No of Bidders 1
4.
Drinking Water Supply and Sanitation #7368565 AOC
Tender For Augmentation Of Uwss Alwar Under Budget Announcement Augmentation Of Uwss Alwar Under Budget Announcement For The Work Of P, L, J And T Of Pipeline, Construction And Commissioning Of Tw, Rcc Reservoirs, Civil Works Pumping Machinery With Emi Including 05 Year Om After 1 Year Of Defect Liability Period - Work ofP/L/J & T of Pipe line, Const. of Tube well, RCC Reservoirs, Civil works, Pumping machinery with EMIetc including 5 years O&M after 1 year defect liability period for Augmentation of UWSS Alwar, Distt. Alwar Sl. No. Item Description 1 Providing,lowering,layingintrenches,aligning,fixinginposition and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas perIS:8329-2000(amended upto date), with internal cement mortarliningsuitableforpotable waterwithrubberring(EPDM) jointsasperIS:5382-1985includingalltaxes(Centralandlocal), transportationandfreightcharges,inspection charges,loading/ unloadingcharges, includingcostoflabourandmaterial,specials (Tee,bendetc.)satisfactoryhydraulictesting,disinfection, commissioningetc.completeaspertechnicalspecificationsand direction of Engineer-in-charge. (excluding earth work)Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 2 100 mm 3 150 mm 4 200 mm 5 250 mm 6 300 mm 7 350 mm 8 400 mm 9 450 mm 10 500 mm 11 Providing,lowering,laying,aligning,fixinginposition andjointing atalllevel/depthsDIstandardspecialswithrubberring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523- 2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material, labour,taxes,testing andcommissioning alongwithpipelineas pertechnical specificationsand direction ofEngineer-in-charge (excluding earth work). 12 All End Socketed 13 Up to 300 mm Diameter 14 Above 300mm and up to 600 mm diameter 15 All End Flanged 16 Up to 300 mm Diameter 17 Above 300mm and up to 600 mm diameter 18 Providing, lowering, laying and jointing in trenches,standard lengths HDPE ISImarkedPipesasperIS-4984:1995(amended up todate) withnecessaryjointingmateriallikemechanical connectors,i.e.thread/insertjoint/quickreleasecouplerjoint/ compression fitting joint or flanged jointand specialsjointing pipe by electrofusionweldingmethod,includingalltaxes, transportationandfreightcharges,inspection charges,loading/ unloadingcharges,stackingofpipes,includingcostoflabourand material,specials(Tee,bendetc.),satisfactoryhydraulictesting, disinfection,commissioningetc.completeaspertechnical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note :Providing andfixing ofall requisitespecials asper drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 19 HDPE PE-80PN-6 20 90 mm dia 21 90 mm dia 22 110 mm dia 23 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, insidelining,outsidecoating,testing and commissioningalong with pipe line as per technical specificationsand directionof Engineer-in-charge. 24 MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) 25 Constructionoftubewellaftercompletionofdrillingbyrotary/percussion method&upto100mtr.depth inalltypeofrocksbyDTHsystem asper IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technicalspecifications.Thework shallbedeemedcompletedonlyafter obtainingsandfreewater.Theborewellshouldhaveathroughoutnominalsize bore beyond casing pipe. 26 Nominal bore 200 mm dia. 27 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 28 Constructionoftubewellfromgroundlevelandupto100mtrdepthand abovetoaccommodatehousingassemblypipeinalltypeofunconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended uptodate)andtechnicalspecifications.Theworkwillincludeloweringof housing andstrainerpipeassemblyandcasingshoeincludingcostofcasing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. 29 Nominal bore 200 mm dia. 30 Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . 31 Supply of ERWM.S. black casing pipe ISI marked (IS: 4270/2001) or amendedup to dateoffollowing sizes 32 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 33 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 34 200 mm dia nominal bore of 5.4mm thickness 35 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casingpipeforsubmersiblecableexternalwork40mmdiacompleteinallrespect. 36 Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. 37 11 KW (15 HP) & head above 120 mtr. 38 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lightingarrangementetc.completesuitableforthreephasepumpset.The panelshouldhavespaceforenergymeter(suppliedbyDISCOM). Allthese equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel shouldbe of minimumsize900 x600 x450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meterreading.Theoperationofpanelshouldbesuitableforon440VoltAC Supply. 39 Above 15 HP and up to 20 HP 40 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 41 3 core 4.0 Sq.mm 42 3 core 6.0 Sq.mm 43 Supply&FixingXLPEinsulated/P.V.C.sheathedcableof1.1KVgradewith aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground asperIS:1255includingexcavationof30cmx75cmsizetrench,25cmthick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 44 16.0 Sq.mm, 4 core 45 Plate Earthingas per IS:3043 with G.I. Earth plate ofsize 600mmx 600mmx 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete withalternatelayersofsaltandcoke/charcoal,testingofearthresistanceas required. 46 Supply & Fixingtube well coverofMS sheet 8mmthick attop &5mmthick 100mmwideshroudaroundtheedgesoastoformacaponthe topend of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre ofMS sheet. A25 mmsocket with end plug shall also be welded over top plate. A GI nipple having outside thread ofsize 1/2 (for installation pressure gauge) shall be provided &welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 47 200 mm dia 48 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), SteeltubeasperIS:1239oramendeduptodateandzinccoatingasperIS 4736,threadedanddoubleflanged(welded)onbothendsandtwonumber 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. 49 65 mm dia 50 Providing,installing,testingandcommissioningofdoubleflangedbulkflow meterwithremovablemechanism,ofclassBconformingtoISO4064/1or amendeduptodateofapprovedmakeincludingcostofallmaterialand labouras per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia. 51 80 mm dia 52 Providing&Fixingofdoubleflanged,CIbody,ISImarkedNRVofapprovedmake of following sizes 53 80 mm dia 54 Supplying&Installing100mmdiametersealeddiaphragmbourdontype pressuregaugeofrange0to10kg. includingalljointingmaterialasperspecification with safety cover. 55 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MSclamps at every 3mtr, jointing materialssuch asnuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 56 80 mm 57 ProvidingandfixingdoubleflangedISImarkedDI ClassK-9pipesasperIS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such asduckfootbend,bend,teeetc.providingandfixingclampsatevery3mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up toandfromvalvechamberasperdirectionofEIC,TechnicalSpecificationandScopeof work. 58 200 mm 59 450 mm 60 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soilas requiredin layers not exceeding 20cm indepth including consolidatingeachdepositedlayerbyramming,wateringetc.anddisposalof surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 61 Dismantlingofcementconcretepavementforpipeline andchambersby mechanicalmeansusingpneumatictools,cuttingtheperipheraledgebyCC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters.Measurementfordismantledtrenchtobemade asperstandard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 62 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1Cement:3coarsesand:6gradedstoneaggregate40mmnominalsize)in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified intenderdocument andno extrapayment shallbe made be madefortrench widthmorethanspecified, completeworkaspertechnicalspecificationand scope of work. 63 Providingand laying in position cementconcrete in specified gradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 64 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 65 Providing, installation, testing and commissioning of submersible dewatering pump setconforming torelevant IScodesandasperscope of work and Technical Specifications, with water proof winding. Pump shall be suitableforvariousdeliveryheadanddischargewithstainlesssteelshaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as per specification,scopeofworkanddirectionofEngineerinChargeof followingpowerrating,suitableforprescribeddutyconditions mentioned in TD. 66 2.2 KW (3.0 HP) 67 Providingandfixing atsitewithnecessarypacking, HorizontalCentrifugal Split Casting pumps with 4 poleinduction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casingandcasingring,SS316impeller,SS410Shaftandshaftsleeve, couplingguard,commonbaseplate,foundationbolts,Cementconcrete foundation etc. complete with all respect as per the specification and scope ofworkanddirectionofEngineerinChargeoffollowingrangeofduty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 68 Discharge 91 to 100 LPS and head 20 to 30 M 69 Discharge 91 to 100 LPS and head 31 to 40 M 70 Discharge 121 to 140 LPS and head 41 to 50 M 71 Discharge 141 to 160 LPS and head 31 to 40 M 72 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 73 80 mm HW 74 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type NonReturnValves(NRV) ofapprovedmakeoffollowingPressurerating& dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of followingspecifications:Body,Cover&discofGreycastironofIS:210/FG200. FacetofacedimensionsasperIS5312(part-1):2004,FlangesDrilledasper IS:1538.Epoxy (Non-Toxic&suitablefordrinkingwater)appliedonbody,cover anddiscinsideandoutside.BodyseatringofSS/CSDoorfacering-EPDM/ Neoprene (food grade quality) ,Shaft ofSS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-BoltasperIS:1363andIS:1367(galvanisedsteel),Insertion rubber of black EPDM 6mm thick. Suitable support structureas perdirections of EIC including jointing & jointing material, labour, testing and commissioning along withpipelineasperTechnicalSpecification&asperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 75 Class PN 1.0 76 250 mm dia 77 500 mm dia 78 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron asperIS:210-FG200,Float-StainlessSteelAISI304/IS:3444, FloatGuide- HBT1.HPOrifice- HTB2/SS,Bodyseatring-Leadedtinbronze/SS.Sealringand face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour,testingandcommissioningasperTechnicalSpecificationsandasper direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 79 80 mm 80 Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuumtight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirmingtoBS-EN-1171/AWWAC-509andoffollowing specifications:Body & bonnet ofDuctile castiron ofgrade GGG40/GGG50as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202F4,Stem/spindleofSSAISI316/410Electrostaticepoxypowder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thicknessof250micronsinsideandoutside,DrilledasperIS1538.Nut-Bolt confirmingtoIS:1363andIS:1367 (Galvanisedsteel)Insertionrubberofblack EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves includingall jointing& jointingmaterial, labour,testingandcommissioningalong withpipelineasperTechnicalSpecificationsandasperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 81 Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 82 150 mm dia 83 200 mm dia 84 250 mm dia 85 350 mm dia 86 450 mm dia 87 500 mm dia 88 MotorizedSluiceValveswithElectricActuatorandintegralstarter ofClassPN1.0 89 300 mm dia 90 450 mm dia 91 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approvedmakeoffollowingclass&diacompleteconfirmingtoBSEN593/BS 5155/IS13095/1991amended up todateandoffollowingspecifications:Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12asperIS 1865or equivalentgrade asper IS :3896-part2-1985 and subsequentrevisions,FacetofacedimensionsasperDIN3202F4/IS13095 DrilledasperIS:1538.ElectrostaticEpoxyPowder(EP-P)/FusionBondedEpoxy (Non-Toxic&suitablefordrinkingwater)coatedwithminimumthicknessof250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene(foodgradequality)anddiscsealretainingringofSS/CS.ShaftofSS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR O ring seal,Nut-BoltconfirmingtoIS:1363andIS:1367(Galvanisedsteel)Insertion rubber of black EPDM 6mm thick. Suitable support structureas perdirections of EIC including jointing & jointing material, labour, testing and commissioning along withpipelineasperTechnicalSpecification&asperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 92 Class PN 1.0, Motorised Operated 93 250 mm dia 94 300 mm dia 95 Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per directionof Engineer.Class PN 1.0 96 250 mm dia. 97 300 mm dia. 98 ConstructionofPumphouseofbrick/stonemasonryofrequiredsize suitableforinstallationofmaximum4no.Monoblockpumpsetsasper approved GA drawing, scope of work and technical specification complete workinallrespectincludingelectricalworksforlightingandfans,rain water drainage. The plinth area of pump house shall be area of measurement. 99 Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing,scopeofworkandtechnicalspecificationscompleteworkinall respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC,600mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4.Superstructurework:StonemasonryinCM:1:6,W-300,height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5.CementmortarpointingonStone masonryandcementmortarplaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7.OntopofwallthereshallbeCCCoping75mmthick(1:2:4)shallbe provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 100 Providingandfixingsteel,gate,gratingandgrillsmadeofangles,tees, square bars,flatsorblackpipe with holdfast andfitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 101 ConstructionofRCCSluicevalvechamberfordifferenttypeofvalves includingearthworkexcavation,100mmPCCM15 aslevellingcourse, RCC M25 grade for base slab, side wall & cover slab , including cost of steelreinforcement,formwork,Pre-castslabs,plasticencapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications andstandard drawings and as per direction of Engineer-in-Charge. 102 Sluice valve chamber of size 1.39m x1.43m x2.245mfor pipe size-from 350-to-450mm 103 Sluice valve chamber of size1.61m x1.75m x2.795mfor pipe size-from 500-to-700mm 104 SITCofUltrasonicFlowMeterofapprovedmakeoffollowingdiasized pipelines and specifications complete:Media : Water (Raw/Clear ) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow velocity range:-10 m/sto+10m/s(bidirectional), Powersupply-80to240v/AC,50 Hz.,Output 1 : 4-20 mA, Communication Output : RS 485, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Acoustic path: single/ dual, Accuracy :± 1% of M.V (max.) for size 50-300mm and ± 2% of M.V (max.) for size 350- 2000mm(singlepath), TransmitterEnclosure:CastAluminium, Sensor cable: encapsulated, Sensor mounting method: V / Z type, Protection type: IP 67, including all materials required for Ultrasonic Flow Meter complete in all respect as per technical specification and as per direction of Engineer In-Charge. 105 UFM 200mm -600 mm (INSERTION TYPE) 106 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 107 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 108 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 109 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. 110 Cold twisted deformed bars (IS : 1786). 111 Providing and laying PVC/XLPE insulated and PVC sheathed unarmoured /Armoured copper cable of 1.1KV grade as per PWD specification for electrical works in existing RCC/Hume/Stoneware/PVC pipe /open duct/ cable trench with filling of exvated earth in trench,on existing cable trays or on surface etc.including making necessary connection testing etc as required of size and as per point (a),(b),(c) mentioned below-(a) Copper conductor of electrlytic grade copper,purity>99.97% ISI marked as per IS:1554 P-1/IS:7093 P-1 (b) conductor shall made of copper rods confirming to IS:613-1964,IS 10810 9Part 0-64) for testing procedures (c) OEM must have ISO 9001 & 14001 certifications & its own in huse NABL lab setup for all testing facilities for cables.Appropriate type test certificate/OEM test report shall be submitted. All above as per approved by Engineer-in-charge.For additional technical parameters of product/work,refer. Annexure A attached with this BSR. 112 25.0 sq mm 4 core 113 35.0 sq mm 4 core 114 50.0 sq mm 4 core 115 70.0 sq mm 4 core 116 SITC of soft Starters with panel supplied by manufacture confirming to applicable standards with logic,inputs & outputs ,relay outputs and analogue outputs plug in I/O connections,display of electrical parameters,state of load and operating time ,RS 485 serial link for connections to Modbus. 117 For siliserh PH90 KW 118 For Ladiya PH Fixed at Kala kua Head works- 75KW 119 For Manu marg PH Fixed at Kala kua Head works-75KW 120 For Manu marg PH Fixed at Malviya nagar Head works-90 KW 121 Electrically operated hoist(EOH) single bridge girder carrying two wheels with chain pulley block,load chain,hand chain,encased gears,trolley track,wheels,axle and shaft,swivel type lifting hook for 5 MT capacity,6 mtr.lift and 9 mtr span 122 Design,Manufacture,Supply,Installation, Testing and Commissioning of indor type PLC Panel of size approx 1000 mm*600 mm*2000 mm (LBH), Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration ,necessary programming software for PLC and SCADA and comprising of all accessories not limited to thefollowing programmable logic controller (PLC) with dual Hot redundant CPU,power supply,Communication module,IO & Processor rack (standard DC),Back up internate /Expension module,Rack(Backplane) 10 slots for IO and processor SCADA software shall have facility VPN,OPC, smart client,web Enabled,Automation Report Generation,Archiving,Treands,Data logging etc. 123 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sum on plan) including disposal ofexcavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed:All kinds of soil 124 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 125 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size). 126 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. 127 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 128 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 129 Cement Mortar 1:3 ( 1-Cement : 3-Sand). 130 Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 131 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 132 75mmthickwith20mmthicknominalsizeaggregate. 133 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 134 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : 135 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 136 Brick masonry with F.P.S. bricks of class designation 75 in superstructure aboveplinth level upto floor fifth level in all shape and sizes in 137 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 138 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :25 mm thick 139 Supplying and filling in plinth with river sand under floors watering ramming,consolidating and dressing complete including cost of sand. 140 Random rubble dry stone Kharanja under floor. 141 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.Size 600mm*600mm 142 Providing and fixing Ist quality MAT finished ceramic tiles size 300*300mm conforming to IS : 13755 and IS:15622 colour such as white, gray,ivory,fume red brown,light green,light blue and other light shades in floors,steps,pillars etc.laid on abed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed) 143 Providing& fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sal wood grade-1 144 Providing and fixing fully panelled/partly panelled/double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - A and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 30mm thick Nigeria wood grade-1 145 Providing and fixing fully panelled/partly panelled/double leaf shutter frame for window and ventilators as per approved design and drawings with approved steel fittings as per Annexure - A and width of styles,bottom & top rails of 75mm including intermediate rails 50mm wide,beading of 25mm*15mm size on both faces : 30mm thick Nigeria wood grade-1 146 Providing and fixing wood panelling or panelling and glazing in panelled and glazed shutters for doors,windows and clerestory windows ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) Panelling for panelled and glazed shutter 25mm to 40mm thick. Nigeria wood grade 1 147 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 148 120cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 4 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. 149 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 150 Colour washing of all shades to give an even shade including all scaffolding : 151 New work (two or more coats) with a base coat of white washing with lime. 152 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: 153 Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 154 Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sand papering,primer,putty etc complete in all respect including scaffolding and safety provision : . 155 New work 156 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 157 Applying primming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 158 White washing with lime to give an even shade including all scaffolding. New work ( Three or more coats) 159 Exterior work-Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding. New work (two or more coats applied @3.84kg/10sqm) 160 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 161 P & F European type white glazed vitreous china Ist quality Double symphonic W.C. (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. 162 P & F Ist quality WVC Urinal (IS:2556 mark) with 25 mm dia G.I. waste pipe, dome couplings, concealed iron brackets or screws etc. complete.Flat back small size 456*355*265mm 163 P & F W.V.C. Urinal Partition plate of approved standard make of size 630x315 mm including making good the wall. 164 P & F C.P. brass Urinal Flush pipe set complete with flanged brackets of approved make.For 2 urinal 165 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make PVC waste pipe with pvc nut 32mm complete including cutting & making good the wall :Size 450*300mm 166 P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor : 167 WVC Lab Sink (IS:2556 Mark) size 450x300x150 mm. 168 P & F G.I. Pipes (Internal work) with G.I. fittings (IS:1239 Mark) & M.S. clamps including cutting and making good the walls and floors :Exposed on wall A class 15 mm dia.nominal bore 169 P & F Pillar Cocks (IS:8931-1993 Mark) of superior quality and approved make : CP pillar cock 15mm dia nominal bore 170 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. 1000 litres capacity 171 Construction of soakage well in all type of soil 300 mm thick dry masonry top and bottom 300 mm course in CM 1:6, 80 mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring, earth work complete as per approved drawing including disposal of earth within a lead of 50 mtr. :Size 300cm dia outside and 300cm depth 172 C.P. brass towel rail elbow type with concealed screws size 450mm (heavy duty) 173 P&F G.I. Piped (External work) wiyh G.I. fittings excludings union (IS:1239 mark) including trenching and refilling ear th etc.15 mm dia nominal bore A class 174 P&F Soap dish or tray of approved quality/ make. C.P. brass heavy duty and superior quality 175 P&F Jet spray for water closet with C.P. copper tube flange of approved make 176 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 177 Medium point (up to 6 mtr.) 178 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 179 On board 180 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 181 20mm 182 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR1.2 MM thick MS sheet boxes 183 75mm x 75mm x 60mm 184 100mm x 100mm x 60mm 185 150mm x 75mm x 60mm 186 P & Fixing Powder coatedCRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and makingholes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 187 1.0 mm thick 188 1.6 mm thick 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 190 1*1.5 sq.mm 191 1*2.5 sq.mm 192 1*4 sq.mm 193 P & F ISI marked (IS:3854) 6 amp. flush type non modular switchwith CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 194 P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 Providing & Fixing of 6 amp. Combined flush typenon modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 196 Providing & Fixing of16 amp. Combined flush typenon modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 197 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 199 1400 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 200 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50mtr.and lift upto 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 201 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia 202 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia 203 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 204 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) 205 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 206 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 207 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 208 Size 9 to 12 mm 209 Size 3 to 5 mm 210 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 211 Cost for Basic Service Charges, Administration and Management, Running of Office, Staff Quarters Comprehensive Operation, Maintenance and Repairs Including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables. Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract. No charges charges for material and equipments will be paid for 1styear of O&M being defect liability period. The contractor should quote rate for DLP accordingly 212 For the 1st year of O&M 213 For the 2nd year of O&M 214 For the 3rd year of O&M 215 For the 4th year of O&M 216 For the 5th year of O&M 217 Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - 218 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 219 f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k)Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 220 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3. 221 2000 KL capacity
Contract Date: May 20, 2025 Contract Value : 17.97 Crore
Government Departments No of Bidders 1
5.
Educational and Research Institute #7183083 AOC
E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Depart. Of Maynaguri Govt. Poly E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Dprt. Of Maynaguri Govt. Poly. , Aggregate Crushing Value Test Apparatus As Per Is:2386 (Part 4) 1963 , Auger Extra Extension Rod, 1 Meter Long With Screw Type Fitting 6 To 12 Ms Auger To Drilling Into Soil Upto 3 M Manually. Mostly Used For Normal Soil And Earthing Pit Purpose. , Blaine Air Permeability Test Apparatus For Measuring Fineness Of Cement As Per Is 5516. Air Permneability Apparatus (Blaine Type) With Isi Certification Mark Is;S516, Fitted In Aluminium Box With Permeability Cell. U Tube Manometer, Mounted On Stand. Perforated Metal Disc. Plunger. Rubber Stopper. Rubber Tube, 20 Cm Long. Filter Paper Discs (Twelve Nos.). Dibutylphthalate Liquid, 100 Ml Bottle. Punch. Non Perforated Disc. Suction Bulb And All Other Accessories Required As Per Is Code. It Should Be Supplied With Standard Cement Required For Calibration(Calibration To Be Done By The Supplier In Presence Of Concerned Authority) And Mercury Of Requisite Quantity, Crucible. , Bod Incubator Chamber Made Of Aluminium 375 Mm X 375 Mm X 450 Mm With 10 Numbers 300 Ml Bod Bottle. Specifications: Temperature Range 5 To 60°C, Temperature Accuracy + / - 0.5°C, Temperature Uniformity + / - 0.5°C, Power 220 Volt, Temperature Control Microprocessor Control, Cabinet M.S. Steel Powder Coated Inner Chamber Stainless Steel, Shelves 3 Stainless Steel, Etc. , Buoyancy Balance Buoyancy Balance Helps In Determining The Specific Gravity And For The Water Absorption Of The Aggregate. It Is Fitted With The 15 Kg Capacity X 0.5 Gm Of The Electronic Balance. Buoyancy Balance Comprising Of An Electronic Balance Of 15 Kg Capacity, Chain & Ratchet Assembly In A Steel Tubular Frame. , Cbr Value Apparatus As Per Is 2720 (Part-16)-1987 Laboratory California Bearing Ratio Test Apparatus, Motorised Laboratory Cbr Apparatus Meets The Essential Requirements Of Is: 2720(Part Xvi) With The Mould As Per Of Is: 9669. , Cod Digester Along With Vials,Holding Rack, 16 Sets Of Glassware (Cod Digestion Tubes With Screw Caps And Cod Air Condensers) Holds 16 Nos. Of 16 Mm X100 Mm Dia Tube. Temperature Range 0- 200 Degree Celcious, Temperature Can Be Set Within This Range. Time Range 0 To 120 Minutes, Stability Plus Minus 0.5 Degree Centigrade, Over Temperature Cut Off. When Digestion Complete, Reactor Automatically Turns Off And Will Sound An Alarm. 230 Volt. 16 Mm X 100 Mm Culture Tubes With Tfe-Lined Screw Caps ( 16 Nos.) Holding Racks Of Stainless Steel. , Compacting Factor Test Apparatus Compaction Factor Apparatus As Per Is: 5515-1983 With Nabl/Nccbm Certificate. , Constant & Falling Headpermeability Apparatus With Water Reservoir As Per Is 2720 (Part 17)-1986. Laboratory Permeability Apparatus: Is: 2720 (Part-17), Is 11209 Suitable For Both Constant Head As Well As Falling Head Permeability Tests. Stand With Three Glass Tubes Of 6 Mm, 10 Mm And 20 Mm Dia Approx. Metallic Mould 100 Mm Dia X 127.3 Mm Height, 1000 Ml Volume. Extension Collar 100 Mm Dia X 60 Mm Height. Drainage Base Plate With A Recess For Porous Stone And An Outlet Valve. Metallic Clamping Ring Drainage Cap With Recess For A Porous Stone And Fitted With Inlet Valve And Air Release Valve. Dummy Plate To Serve As False Bottom During Compaction. Porous Stone For Drainage Base Plate. Porous Stone For Drainage Cap Rubber Connection Tube 3M Long, With Pinch Cock. Overhead Tank, Required For The Constant Head Method Made Of Steel, Approx. 37.5 Cm Dia And 1M High. It Is Provided With An Inlet Port At The Top, Six Outlets At The Bottom With Cocks, Air Inlet And Water Filling Tube At The Top. An Arrangement To Indicate The Water Level Is Also Provided With Rammer 2.6Kgx310 Mm Controll Fall And 4.9Kgx450mm Controll Fall. , Cube Mould, Size: 150 Mm X 150 Mmx 150 Mm (Made Of Cast Iron With Isi Certification) , Cube Mould, Size: 70.6 Mm X 70.6 Mmx 70.6 Mm (Made Of Steel With Isi Certification) , Cylindrical Core Cutter With Steel Dolley, Steel Rammer And Other Accessories. Apparatus Should Consists Of: 1. Cylindrical Core Cutter Of Steel Material Of About 130 Mm Long And 100 Mm In Diameter. 2. Steel Rammer Of About 140Mm.Dia., 75Mm Height And 900Mm (Total Height Including Handle.).Weight Of Rammer Should Be Of 9 To 10 Kg. 3. Steel Dolly 25 Mm High And 100 Mm In Diameter. 4. Palette(Steel) Knife 5. Steel Ruler. 6.Metal Straight Edge. 7. Spade Or Pickaxe.. 8 Apparatus To Extract Core Sample. 9.Moisture Cans(Six Nos. Of Aluminium Material). , Cylindrical Metal Measure (3, 15 And 30 L Capacity) For Determination Of Specific Gravity Of Coarse Aggregates As Peris 2386 (Part Iii) : 1963 , Density Basket Conforming To Is: 2386(Part-Iii)-1963 For Determination Of Specific Gravity & Water Absorption. It Is Made Of G.I. Wire-Mesh Of Approximate Size 20 Cm Dia X 20 Cm High. Complete With Handle. , Desiccator( 250Mm Dia , Material Pp/Pc) , Digital Flocculator With Six Jar (Standard Jar Tester) Designed For Floc Formation Test In Water Treatment Plant. Uniform Stirring Of Up To 6 Samples Simultaneously. Variable Speed Of 20-100 Rpm. Heavy Duty 1/20Hp Motor With Gear Train Mounted On A Mild Steel Housing. Supported By Six Rods On A Bench. Stainless Steel Stirring Paddlers With Adjustable Height. Locking Collars Or Stirring Rods Permit Adjustment Height Of Paddle Height. Spacing Of 6” (150Mm) Between Rod Permit Uses Up To 1000Ml Beaker. Housing Material: Crc / Ms Sheet Duly Powder Coated. Power Consumption: 220/230V Ac Supply 50Hz Single Phase. Motor: 1/ 20Hp Motor Good Quality. Compulsory: Digital Rpm Meter/Timer/Dc-Drive For Low Rpm Illumination: By Tube Lights (With Choke + Stirrer) Duly Covered By Perspex Sheet Having Control Switch Fitted On The Control Panel. , Digital Planimeter Digital Planimeter- (Specification: Roller Type, Accuracy-(+-) 0.2%(Within (+-) 2/1000 Pulses), Accumulated Measuring Value Maximum 10 Sq.M (Scale 1:1), Measuring Range-A) Maximum Vertical Width 325 Mm,B) Horizontal Roller Rotatant Length-30M, Display Liquid Crystal, 8 Digit Figures. Higher Specification Will Be Preferred.) , Digital Rebound Hammer With Calibration Anvil (For Concrete Compressive Strength Analysis In The Field) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881 202 And Other International Standards. Range:10 To 70N/Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Relbound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Softvware And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided. , Direct Shear Test Apparatus As Per Is 2720 (Part13)-1986 12 Speeds, Motorised Is: 2720 (Part Xiii) Is: 11229 Supplied Complete With Proving Ring And 2Nos. Of Dial Gauge Of 0.01X 25Mm. 2Kn With Dial Gauge 2 Nos.& Compression Tension Proving Ring 2Kn; Type Of Shear : Direct / Residual Measurement, Operation : Motorised The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Suitable For Operation With 220V, 50 Hz, Single-Phase Supply. It Comprises: - I) Shear Box Assembly (Halves Of The Shear Box 2 Nos),60 Mm Square, Complete With A U-Bracket, Guide Pins And Spacing Screws, Made Of Brass. Ii) Gripper Assembly Consisting Of Two Plain Grid Plates, Two Perforated Grid Plates, One Base Plate And One Loading Pad, All Made Of Brass. Iii) Two Porous Stones, Each 6 Mm Thick, Fitting The Shear Box Iv) Shear Box Housing Of Brass, Complete With Two Ball Roller Strips. V) Loading Unit With Normal Loading Of 3 Kg/ Cm2 On 60 Mm Square Specimen. Vi) Specimen Cutter For A Specimen Size Of 60 Mm X 60 Mm X 25 Mm. Vii) The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Surcharge Weights To Attain Normal Stress Of 3 Kg/Cm2 1 Set, Surcharge Weight Set Comprises Of Following Weights : 0.05 Kg/Cm2: 4 Nos.; 0.10 Kg/ Cm2: 1 No.; 0.20 Kg/ Cm2: 1 No.; 0.50 Kg/ Cm2: 3 Nos.; 1.00 Kg/ Cm2: 1 No. 1. Conforming To Is 2720 (Part – 13) Of Latest Edition , Ductility Testing Apparatus As Per Is: 1208 -1978 Ductility Testing Machine (Is: 1208 -1978) For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould (Total Length 75 0.5 Mm, Distance Between Clips 30 0.3 Mm, Width At Mount Of Slip 20 0.2 Mm, Width At Minimum Cross Section 10 +0.1 Mm, Thickness Throughout 10 + 0.1 Mm) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm/Mnt And S Cm/Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. , Electronic Balance, Capacity 2 Kg. Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 2 Kg And Sensitivity As 0.01 G. , Electronic Digital Balance(20Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 20 Kg And Sensitivity As 1 G. , Electronic Digital Balance(25Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 25 Kg And Sensitivity As 1 G. , Pipe Friction Apparatus The Apparatus Is To Be Used To Measure Darcy’S Friction Coefficient (F) For Fluid Flow Through A Given Pipe. The Apparatus Should Consist Of: • A Centrifugal Pump Of 25Mm X 25Mm With 1/2 Hp Mono-Block Pump (Kirlosker Or Equivalent Make), • Sump Tank (80 Cm X 35Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) To Collect The Water, • Measuring Tank ( 45Cm X 30Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) Fitted With Piezometer Tube To Measure The Discharge, • G.I. Pipe Of Internal Diameter 25.4Mm (1) And Isi Marked Control Valve And Regulating Valves To Be Provided To Circulate Water, • Bye-Pass Line Is Also To Be Provided Along With Regulating Valve To Regulate The Discharge, The Apparatus Should Consist Of Three G.I. Pipes Of Internal Diameter ½”, 3/4 & 1” Respectively. The Pressure Tapings Are Provided 100Cm Apart On Each Pipe. Each Tapings Are Connected To The Mercury U Tube Manometer To Measure Head Difference. Hand Shuts Valves Are To Be Provided At Each Pipe Inlet And Outlet To Control The Supply In The Pipe. The Tanks And All Other Ms Fittings Should Be Well Epoxy Painted (Both Inside & Outside) To Prevent Rust. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Apparatus And Installation And Demonstration Are To Be Given. , Flash And Fire Point Apparatus Pensky Martens Flash Point (Closed) Tester (Electrically Operated) With Npl Certificate Is: 1448 (Part 21) 1209, Ip 34/58, For Determining Flash Point Of Petroleum Products (Above 490C Flash Point Range). It Has A Brass Coil Cup Fitted With A Heat Resistance Handle. The Cup Is Provided With A Lid Which Includes Stirring Device, A Cover, Shutter And A Flame Explosive Device. The Shutter Is Operated By A Spring Handle. A Flexible Shaft Is Provided In The Hand Operated Stirrer. A Cast Iron Stove Is Fitted With A Metal Top Plate Mounted On An Upright Member (Gas Manifold) And It Feeds A Needle Valve-Controlled Burner Supplied With A Hot Plate. The Energy Regulatory Controls The Heating. Suitable For Operation On 220 V, 50 Hz, Single Phase Ac Supply. Flash Point (Open) And Fire Point Cleveland With Npl Certificate Electrical Heating Thermometer Range: -6°C To +110°C (Low Range), 90°C - 370°C(High Range) Ref. Standards - Is:1448 (Part 69), For Determining The Flash And Fire Points Of Petroleum Products, Except For Fuel Oil And Those Products Which Have Open Cup Flash Point Below 79° C (175° F). Consisting Of Cleveland Flash Cup Brass (Dia. 63 - 64 Mm, Height 32.5 - 34 Mm, With A Filling Mark Is Engraved At A Distance Of 9 To10 Mm Below The Surface Along With An Insulated Handle. Gas Test- Jet Assembly Correctly Positioned And Pivoted From A Cast Cup Platform Which Is Fixed To A Heating Bath. Energy Regulator, To Regulate The Rate Of Rise In Temperature 220 V, 50 Hz, Single Phase, Ac Supply. With Thermometer Ip28c Range: -6°C To +110°C. , Heating Mantle For Bitumen Test As Per Is And Branded , Hot Air Oven Electrically Operated With Digital Indicator Cum Controller With Safety Alarm, Range 50°C To 250°±1°C With Air Circulating Fan, S.S, Inside Size 600 Mm X900 Mm X450 Mm , I.S. Sieves[For Aggregate (Coarse And Fine Aggregates & Soil] 1. Sieve G.I. Frame Material Of Construction: G.I; Protective Coating : Powder Coating; Weight: Preferably 800Gm- 900Gm; Wire Mesh Preferably Imported Quality Size: 100Mm, 80 Mm, 63Mm, 50Mm, 40Mm, 31.5 Mm, 25 Mm, 20Mm, 16 Mm, 12.5Mm, 10Mm, 6.3Mm, 4.75Mm, [Bis:460 Part I & Ii 1985, Reaffirmed 2008] ; Pan And Cover For 30Cm Dia Sieves Material Of Construction: G.I; Protective Coating : Powder Coating Upto 6.3 Mm And The Rest Are Made Of Brass (As Mentioned Earlier) Weight: Preferably 800Gm- 900Gm; 2. Sieve Brass Frame 20Cm Dia Material Of Construction: Brass Type: Seamless Weight: Preferably 250Gm- 350 Gm Wire Mesh Preferably Imported Quality Size: 4.75Mm, 2.36 Mm, 2 Mm, 1.18 Mm, 600 Micron, 425 Micron, 300 Micron, 150 Micron, 90 Micron 75 Micron [Bis:460 Part I & Ii 1985, Reaffirmed 2008] Pan And Cover For 20Cm Dia Sieves With Lid And Pan Conforming To Is:460 Part I 1978; With Brushes For Cleaning Sieve. , Length Gauge Conforms To Is:2386 (Part-I) , Los Angels Abrasion Testing Machine With All Accessories Los Angeles Abrasion Testing Machine With Counter (As Per Is: 10070-1982) , Mechanical Liquid Limit Device With Grooving Tool (Casagrande And Astm), Porcelain Evaporating Dish , Spatula, Palette Knives As Pe Is : 9259-1979. , Piezometer Tube It Consists Of Glass Tube Connected To A Vessel At Which Static Pressure Is To Be Measured. It Is The Simplest Of All The Manometers. It Is Used To Measure Very Low Pressures. The Shape And Size Should As Per Indian Standard. The Glass Material Should Be Of Good Quality, Virtually Unbreakable And Should Not Show Any Type Of Distortion During Experiment. The Cost Of The Item Should Include Supplying, Installation, And Demonstration. , Plane Table Set 1.Plane Table – It Should Be Well Seasoned, Good Quality Drawing Board Made Of Pine/Teak Wood Having Smooth, Plane Finish On Its Top And Fitted With Ball And Socket Arrangement Of Size 60Cmx50cmx1.5Cm Or 75Cmx50cmx1.5Cm. 2. Plane Alidade – Plane Alidade Should Be Of Metallic (Brass Or Gun Metal) With A Fine Beveled Edge. 3.Spirit Level:- Tubular Level, Which Can Be Placed In To Perpendicular Position. 4. Trough Compass:- Usually 15Cm Long And Provided With Magnetic Needle To Facilitate Orientation Of The Plane Table And To Mark North Direction. 5. U-Frame Plumbing Fork:- Hairpin-Shaped Brass Frame Having Two Arms Of Equal Length One End Of Frame Is Pointed, The End Of The Frame Carries A Plumb Bob. 6. Clamps :- Minimum Four Nos. Of Suitable Size. 7. Tripod Stand:- Should Be Of Standard Size Of Either Aluminium Or Good Quality Wooden Material. 8. Plumb Bob:- Standard Size ,Brass Metal. , Plastic Limit Apparatus Conforming To Is: 2720 (Part V) , Proctor Test Apparatus [Light And Heavy Compaction] Proctor Compaction Test (Modified And Standard) Bis: 2720-Part 7 1974. , Pycnometer For Determination Of Specific Gravity Of Sand And Fine Gravel. Consisting Of A Glass Jar Of 1 Kg Capacity, Complete With Brass Cone, Rubber Seal And Screwed Cap As Per Standard Is: 2386 (Part Iii). , Ring And Ball Apparatus Conform To Is:1205 (Electrically Operated) Ring And Ball Apparatusas Per Is: 1205, , Sand Replacement Apparatus [Large] As Per Is:2720 (Part Xxviii). , Sand Replacement Apparatus [Small] As Per Is:2720 (Part Xxviii). , Survey Umbrella , Shrinkage Limit Apparatus (Supplied With Requisite Quantity Of Mercury) The Apparatus Conforms To Is: 10077, And The Test Is Performed As Per Is: 2720 (Part Vi). The Set Consists Of: I) 75 Mm Square Prong Plate Made Of 3 Mm Thick Acrylic Sheet With Three Metal Prongs. Ii) Stainless Steel Shrinkage Dish 45 Mm In Dia, 15 Mm Deep. , Sieve Shaker, Motorised Having As Tardy Cast Iron Body, The Shaker Has An Inclined Sieve Table Which Can Accommodate A Max Of Seven Sieves Of 200 Mm Dia. An Adjustable Top Clamping Plate Is Provided To Hold The Sieves. The Table Has A Gyratory Motion In Addition To Up And Down Jolting Action. The Operating Gear Assembly Is Enclosed In An Oil Bath Fitted With Transparent Oil Level Indicating Window. Suitable For Operating On 220V, 50Hz, Single Phase Supply. Time Switch Adjustable From 0-60 Minutes; Lid And Receiver For 200 Mm Dia Sieves, Made Of Brass; Adopter For 300 Mm Dia Sieves; , Slump Test Apparatus With Tamping Rod And Base Plate Slump Test Apparatus As Per Is: 7320-1974. , Thickness Gauge As Per Is 2386 (Part I) : 1963 , Total Station Total Station.Telescope: Magnitication : 30X Or Better; Image : Erect; Angular MAsurement: Angular Accuracy : 5 Or Better: Least Count: 1 Or Better; Distance Measurement: Distance Range With Single Prism : 2.2 Kms Or Better (Under Normal Conditions) Distance Without Prism : 270 M Or More Laser Output In Prism Mode Class1 (Safe For Human Eye)Distance Accuracy In Prism Mode: 2Mm 2Ppmxd Or Better General:Display : Dual Face Alpha Numeric Keyboard (Identical Display)Compensator : Type: Dual Axis / Range: 3 Or More. Battery Rechargeable Battery (Operational Time Approx.12 Hrs Or More For Each Battery |2 Nos Battery To Be Supplied| Quick Charger. : Ino.Dust & Water Proof Protection : Ipss Or Better.Optical Plummet : 3X Or Better/Llaser Plummet Weight With Handle & Battery :5 Kgs Or More.Memory Management System With Multiple Data Interfaces As:Internal Memory : Approx 10,000 Points Or More. Plug In Memory Device : Usb Flash Memory. Accessories:Aluminium Telescopic Tripod. : Inosingle Prism Assembly Consisting Of: Inorange Pole, Prism, Target Plate, Spirit Bubble, Tripod All In Carrying Cases.Data Communication Sottware : Lnothe Minimum Tolloving Application Software Should Be Loaded In The Instrument.Topography, Resection, (Setting Out Of Co-Ordinates, Line, Arcs), Area Calculation, Etc. Catalogue Of The Quoted Model To Be Enclosed With The Bid (Without Which Bid Should Not Be Considered For Technical Evaluation, Physical Training To The Respective Institute After Successful Supply, Ater Sales Service Is Also Mandatory As When Required, , Turbidity Meter With Standard Solution Specification For Bench Top Turbidity Meter With Digital Display: Supply, Installation, Commissioning, Functional /Performance Testing, Demonstration, Training And Warrantee From Oem Or Their Authorized Dealer For Bench Top Turbidity Meter With Digital Large Full Colour Touch Screen Display Unit & Easy Data Export System Having Minimum Following Specification And Including Specified Numbers Of Standard Accessories. The Instrument Should Be Operable On 220 V Ac, 50 Hz. Specifications Range Turbidity Range (Ntu): 0 To 4000 Ntu (Nephelometric Turbidity Unit) Range Selection: Automatic Resolution: 0.001 Ntu, Accuracy: ± 2% Of Reading Plus 0.01 Ntu From 0 - 1000 Ntu, ±5% Of Reading From 1000 - 4000 Ntu Or Better Repeatability: ±1% Of Reading Or 0.01 Ntu Whichever Is Greater Light Source: Tungsten Filament Lamp Standard : Designed To Meet Epa 180.1 Response Time: < 15 Seconds Operation And Service Manual Should Be Included With The Main Instrument At The Time Of Supply. Instrument Should Have All The Standard Accessories Like Silicone Oil, Oiling Cloth, Filter Assembly, Sample Cells With Caps , Turbidity Standardization Solution Kit, Calibration Kit, Dust Cover At The Time Of Supply. Instrument Should Be Latest Model And It Should Not Be The Obsolete Model. , Universal Testing Machine (100T) Analogue, Universal Testing Machine As Per Is, Capacity 100T. , Vicat Apparatus Vicat Apparatus With Isi Certification Mark Is:5513 Fitted In Aluminium Box (Is-1727, 2541 (P.2), 2645, 4031) The Mould Is In The Form Of Frustum Of A Cone Having Internal Diameter At Lower And Upper End 70 And 60 Mm Respectively And A Height Of 40 ± 0.2 Mm. Needle For Initial Setting Time Determination: The Needle Is Circular/Rectangular In Cross-Section Having A Cross Sectional Area Of 1Mm².With Flat End.- 3Set Needle For Final Setting Time Determination: Having A Cross Sectional Area Of 1Mm² With Flat One End And A Collar At The Other End Having Dia Of 5 Mm And Needle Projects Beyond The Collar By 0.5 Mm – 3Set Polished Brass Plunger With A Projection At The Upper End For Insertion Into The Movable Rod With Flat Lower End Dia 10 Mm, 50 Mm Long- 3Set Sample Capacity : 400 Gms.( Ordinary Portland, Rapid Hardening Portland, Low Heat Portland)Front Scale Should Be Made With Brass (Can Be Measured From Top And Bottom ) Provided With Standard Bottom Glass Plate For Mould As Per Is Code , Bernoulli’S Apparatus The Self-Contained Experimental Set-Up Is To Be Provided With Water Recirculating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. An Arrangement Is To Be Provided To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Test Section: Material Acrylic, • Piezometer Tubes: Material P.U. Tubes (7 Nos), • Water Circulation: 0.5. H.P. Pump, • Flow Measurement: Using Measuring Tank With Piezometer, Capacity 25Lts. • Sump Tank: Capacity 70 Lts., • Intel Tank: Capacity 20 Lts., • Stop Watch: Electronics, • Control Panel Comprises Of Standard Make On/Off Switch, Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. • The Inside Surface Of The Tank And All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Combined Venturimeter And Orificemeter Apparatus The Apparatus Should Consist Of 2 Pipe Line Emerging Out From A Common Manifold. One Pipeline Contains A Venturimeter, Second Contains An Orifice Meter. The Pressure Taping From The Venturimeter And Orifice-Meter Are Taken To Differential Manometer To Measure Pressure Difference. The Venturimeter And Orificemeter Are Connected In Parallel And Any One Of Them Can Be Put In Operation By Operating Valves Provided At The Upstream And Downstream. The Flow Can Also Be Regulated By Theses Valves. The Set-Up Is To Be A Self-Contained Water Re-Circulating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. Flow Control Valve And By-Pass Valve Are Fitted In Water Line To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Venturimeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Orificemeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Water Circulation: 0.5. H.P. Pump (Standard Make). • Flow Measurement: Using Measuring Tank, Capacity 40 Ltrs. • Sump Tank: Capacity 60 Ltrs. • Stop Watch: Electronics. • Control Panel Comprises Of: Standard Make On/Off Switch Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. The Inside Surfaces Of The Tank All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Water Distillation Apparatus The Still Is An Essential Part Of Equipment In Modern Material Testing Laboratories. In Operation The Water Is Heated Gently And Converted To Steam By Keeping It Boiling At A Slow Rate. The Steam Is Condensed In An In-Built Condenser And The Distillate Collected In A Receiver. This Is Free From All Impurities And Gases. Cooling Water Consumption 60 Liter/Hr Biological Activity Pyrogen Free Ph 6 -7 Conductivity S/Cm <3 × 10-6 Distillate Temperature 65 - 75?C Copper, Brass, Bronze And Tin Are Used In The Fabrication Of The Stills. The Surfaces Coming In Contact With Water Are Heavily Tinned Which Prevents Metallic Contamination. A Water Inlet Valve Is A Part Of The Still For Connecting To A Tap. An Overflow Is Also Provided To Maintain The Water At Proper Level. The Still Has4 Litre/Hour Distillation Capacity, Suitable For Operation On 220 V, 50 Hz, Single Phase Supply. , Kvl , Kcl Trainer Kit With Adequate Voltmeter Ammeter And Multi Meter , Rlc Resonance Trainer Kit , Analog Micro-Ammeter(0-1000?A) (Ac) , Analog Milli-Ampere(0-1000Ma) (Ac) , Digital & Analog Bread Board Trainer , 8085 Trainer Kit 16 X 4 Line Lcd Display & 101 Pc Key Board. With Power Supply & Rs232c Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8255 Study Cum Logic Control Card , 8 Bit Adc & Dac , 8051 Trainer Kit 16X4 Line Lcd Display & 101 Pc Key Board With Power Supply & Rs 232X Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8051 Development Board , Stepper Motor & 12V Dc Motor Control With Motor Mounted & Direction Control , 8 Bit Adc & Dac , Lcd Interface Module , Relay Interface Module , Digital Ttl Logic Gate Trainer Kit , Digital Cmos Logic Gate Trainer Kit , Adder/Subtractor Trainer Kit , 4 Bit Multiplexer & De-Multiplexer Trainer Kit , Flip Flop Trainer Kit , 4Bit Shift Register Trainer Kit , Decade Counter Decoder Driver & 7 Segment Display (With 1 Hz Squarer Generator) Trainer Kit , Programmable Counter Using 7490 Ic Trainer Kit , Digital To Analog And Analog To Digital Converter Trainer Kit , Bcd To 7 Segment Decoder Trainer , Ic 555 Trainer Kit , Linear Potentiometer (With Scaling) , Rotary Potentiometer (With Scaling) , C Type Bourdon Tube Pressure Gauge (Spec: 0- 100Psi, Accuracy 1%) , Dead Weight Tester With Bourdon Tube Pressure Gauge , Dead Weight Tester With Bourdon Tube Pressure Switch , Strain Gauge Load Cell , Lvdt Trainer Kit , Hall Sensor Trainer Kit , Piezoelectric Transducer Trainer Kit , Stroboscope , Rtd , Thermocouple , Thermistor , Pyrometer , Manual Installation Of Flow Line Along With The Different Flow Measuring Instruments (Orifice, Venturi, Rotameter, Magnetic Flow Meter, D/P Transmitter) , Conductivity Gage For Level Measurement , Capacitive Gagefor Level Measurement , Gauge Glassfor Level Measurement , Float Typefor Level Measurement , Displacer Typefor Level Measurement , Control Valve , Temperature Control Loop With Using On Off Controller With Temperature Sensor , Complete Set Up Of Process Control Unit For Level & Flow Using Analog Dp Transmitter & Computer Interface With Pid Control Full Set Without Pc. , Complete Set Up For Single Loop Flow Control Unit Using Mass Flow Meter With Control Valve. , Pid Controller Master Unit Containing Analog Pid As Well As Pc Based Pid With Computer Interface Adaptor & Self Extracting Pid S/W On Cd With Process Simulator Panel. , Pcb Stencil Printer , Dc Shunt Motor: ½ Hp, 220V,1500 Rpm (Gee Make)Dc Starter : ½ Hp , 220V, 3-Point Starter, Panel Mount Type, Ammeter : 2A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Voltmeter: 300V, Mc Type,Panel Mount, 96 Sq. Mm (Ae Make), Ammeter: 1A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Rpm Meter: Digital, Panel Mount With Proximity Sensor (Select Make), Rheostat :( 0-50O, 5A, And 0-500O, 1.5A) Screw Motion Type, Cont. Variable, Potential Divider: 500O, 2A Screw Motion Type, Cont. Variac-1No. Motor Are Fitted On Ms Channel Base. All Meters, Starter- Are Mount On Self Stand Bakelite Panel Board. All The Terminals Of The Motors, Meters, Starter, Mcb Etc. Brought Out On The Panel For Flexible Connection With Connecting Patch Cords. , Transformer : 1 Kva, 230V / 115V, 50 Hz Variac : Single Phase, 10A, Input : 230V, Output : 0-270V, 5A, Voltmeter: 300V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 150V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 50V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Ammeter : 0-5A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 0-10A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make) : 0-1A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Wattmeter: 300V / 5A, Digital, Pf : 0.2 To 1.0, Class : 1, 96 Mm X 45 Mm (Schneider).All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board.All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Variable Dc Source : 0-24V, 0-500Ma, Continuous Variable Dc Source Dc Voltmeter: 0-50V, Mc Type, Class : 1.0, 96 Sq. Mm. Ammeter :0-1A, Mc Type, Class : 1.0 96 Sq. Mm. Load : 0-500Ma, 24V Resistive Load, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Kelvin Double Bridge:Range Of Measurement: 0.1? – 0.92?, One Digital Galvanometer Provided To Indicate The Balance Conditions. Required Patch Chords Are Provided. Input Voltage :15V Dc Output Voltage :5V Ac, Output Current :1 Amps, Kelvin’S Double Bridge, Patch Cards, 1A Power Supply Adaptor, Manual , Insulation Tester (Hand Driven Generator Type), Rated Resistance: 0-2000 Mohm, Rated Voltage: 500 Volts, Scale Length: 90Mm (Approx.), Rotation Speed: 160 Or More R.P.M , Fluorescent Lamp Set Up With Copper Ballast, Starter, Capacitor Etc. (Philips) Variac : Input :230V Ac, Output : 0-250V, 2A, Panel Mount Type (Penta), Wattmeter : Digital Panel Type, 0-300V / 0-2A (Schneider Make), Voltmeter : Digital Panel Type. 0-300V Ac (Select Make) – 3 Nos. Ammeter: Digital Panel Type. 0-2A Ac (Select Make),All Mount On A Self Stand Bakelite Panel Board. All The Terminals Of Each Inst. Brought Out On The Panel.Connecting Patch Cords, Dp Mcb, Indicator. , Wien Bridge: Supply:- ±12V D.C. At 100Ma, Ic Regulated Power Supply Internally Connected1khz Sine Wave Oscillator Audio Amplifier And Speaker For Null Detection Three Decade Resistances, Single Dial In Steps Of 100 Ohm, Total 1K Each,Two Dials Of 10 Ohm & 100 Ohm, Total 1100 Ohms To Form Arms Of Bridge Decade Standard Capacitance, Selectable By A Band Switch To Form The One Arm Of The Bridge Unknown Capacitor And Adequate No. Of Other Electronic Components Mains On/Off Switch, Fuse And Jewel Light The Unit Is Operative On 230V ±10% At 50Hz A.C. Mains Adequate No. Of Patch Cords Stackable From Rear Both Ends 4Mm Spring Loaded Plug Length ½ Metre Good Quality, Reliable Terminal/Sockets At Appropriate Places On Panel For Connections/Observation Of Waveforms , Maxwells Inductance Bridge: Four Arms Are Provided With Suitable Connectors, 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge, Measurement Range 15Mh – 200Mh, Connector Facility Given To View The Output Of The Bridge Externally By Cro, Patch Chords, Input Voltage 15V Dc, Output Frequency 1Khz, Output Voltage 2V Ac, Output Current 0.5 Amps, Patch Cords, 1A Power Supply Adaptor. , Schering Bridge: Built In Dc Power Supplies Fixed. Operated On Mains Power 230V, 50Hz +10%, Sine Wave Generator: 0-1Khz Sine Wave Oscillator, Null Detector: Speaker, Componentsmounted On The Panels : Arm, R1 Four Decades Of Resistance 1 Ohm To 10K Ohm Through Rotary Switch. Arm, R2 Six Different Values Of Resistance Through Rotary Switch. Arm, Cx Three Different Values Of Unknown Capacitance Through Rotary Switch.One Arm Asfixed Capacitor. , Scr- Trainer Kit: Variable Dc Source: 0 ~ ±250V, 0.75A, Variable Dc Source: 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Simple Screw Jack Appratus , Worm And Worm Wheel Appratus , Double Purchase Crab Winch Appratus , Horizontal And Inclined Plane Friction Slide Apparatus , Haematite Ore (1 Kg) , Copper Pyrites (1 Kg) , Powdered Coal Sample (1 Kg) , Tlc Uv Cabinet , Hot Plate With Magnetic Stirrer , Magnetic Stirrer , Digital Muffle Furnace (220-230V, 900°C) , Sample Cells (Round Glass, 10 Ml) , Sample Cells (Square Glass, 10 Ml) , Chloroscope , Air Compressor , Digestion Vessels (12 Pieces Box) , Block Heater , Ampule Sealer , Borosilicate Culture Tubes (16Mm×100Mm×150Mm) With Tfe Lined-Screw Caps , Parafilm Tape , Determine The Permeability Of Magnetic Materials By Plotting Its B-H Curve. Trainer Operated On 230V With 10% Variation, Sufficient Number Of Patch Cords, With Computer Lead, 12 X 8 With Shock-Proof Ply Box, Three Different Values Of Capacitors Are To Be Given On Board. • One Variable Potentiometer • Different Circuit Diagram Is Printed On Board. • Step Down Teansformer With Demonstration Transformer With 2 Secondary Coils And One Primary Coil. • Output Through Bnc Connectors And Bnc Lead Are To Be Provided For Output To Cro. • Components Mounted On The Front Panel. , Set Up For Measurement Of Voltage Current And Power Variable Ac Supply: 0-230V, 0-5A, Continuous Variable Ac Supply, Ac Voltmeter: 0-300V, Mi Type, Class : 1.5,Ammeter : 0-5A, Mi Type, Class : 1.0 96 Sq. Mm. (Ae Make), Wattmeter:230V,5A, 1000Watt, Analogtype, Panel Mount, Load : 0-5A, 220V Resistive Load, Step Variable, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords, Operating/Instruction Manuals. , Set Up For Visualization Of Phase Difference Between Voltage And Current In Series R-L And Series R-C Circuit Analog Meters: Ammeter 20Ma Ac.Voltmeter 20V Ac. Components Are Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch. Dso- 2Channel, 50Mhz Table Top-1No. , Measure Voltage, Current, Power, P;Ower Factor In A R-L Series Circuit Resistance: 0 - 500O / 2A, Step Variable, Inductance: 0-200Mh / 2 Amps, Step Variable, Voltmeter: 0-300V Ac, Digital Panel Type– 4 Nos.Variac: 0-250 Volts / 4 Amps, Panel Mount Type, Single Phase, Ammeter ; Digital Panel Type. 0-2A Ac Wattmeter:- 230V/5A, 1000Watt Digital Panel Mount, All The Meters Mount On Bakelite Panel Board With Toggle Switches, Terminals, Connecting Wires, Rotary Switches, Sockets, Operating Manual Etc. , Identify Different Parts Of A Single Phase Transformer, Ac And Dc Motor. Dc Machine-0.5Hp, 220 Volts, 1500 Rpm, Compound Wound Dc Machine. Parts I.E. Armature, Shunt Field, Series Field, Commutator, Carbon Brass, Carbon Holder, Carbon Rocker, Ball Bearing, Bearing Lubricant, Bearing Guards, Cooling Fan Etc. Are Properly Paints And Marking For Easy Understanding. Three Phase Induction Machine (Squirrel Cage)- 1 Hp Capacity, 415 Volts, 1460 Rpm, Three- Phase Sq. Cage Induction Motor. All Parts I.E. Stator Winding, Sq. Cage Rotor, Cooling Fan Are Properly Paints And Marking For Easy Understanding. (Each Set) Transformer (1-Ph) : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, An Cooling– 1 No. , Determine The Transformartion Ratio Of A Single Phase Transformer And Measure No Load And Full Load Current Transformer : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, Normally Air Cooled, Variac:Single Phase, Panel Mount Type, 0-250 Volts, 10 Amps, Wattmeter : 0-300 Volts / 0-5 Amps, Single Phase, Digital Type (Schneider), Voltmeter: 0-300 Volts, Ac, Panel Mount, Digital Type (Select)– 2 Nos. Ammeter: 0-1 Amps, Ac, Panel Mount, Digital Type (Select) Ammeter: 0-10 Amps, Ac, Panel Mount, Digital Type (Select) – 2 Nos. Load : 0-5A, 220V Resistive Load, Step Variable,– 1Set. All Meters Are Mount On A Self Stand Bakelite Panel Board. All The Terminals Of The Meters Etc. Brought Out On The Panel For Flexible Connection. With Connecting Patch Chords, Operating Manuals Etc. , Identification Of Different Active And Passive Lements In A Given Circuit Different Type Of Resistors, Capacitors, Diodes, Zener Diodes, Transistors (Npn & Pnp Type), Transformers, Inductors,Regulator, Op-Amp Ic, Fet, Mosfet Etc. All Above Mentioned Components Fitted On Acrylic Sheet With Proper Marking And Symbol. , Familiarization With Multimeter To Measure The Value Of Given Resistor And To Confirm With Clour Code Digital Multimeter Meeting Iec1010standard. Ce Resistance:- Different Value Resistance (Cfr And Mfr Type)-1No Each. With Colour Code.Inductor :- Different Value Inductor -1No Each. With Colour Code. Capacitor :- Different Value Capacitor -1No Each. With Colour Code. , Use Of Lcr-Q Meter To Measure The Value Of A Given Capacitor And Inductor • Dual Backlit Lcd Display. Auto Lcr Smart Check And Measurement. Series/Parallel Modes Are Selectable. • Ls/Lp/Cs/Cp With D/Q/ T/Esr Parameters. Support Dcr Mode 200.00O~200.0M?. Five Different Test Frequency Are Available: 100/120/1K/10K/100K Hz. • Test Ac Signal Level: 0.6Mvrms Typ. Test Range: (Ex. F=1Khz). L: 200.00 ?H ~ 2000.0 H. C: 2000.0 Pf ~ 2.000 Mf. R: 20.000 O ~ 200.0 M?. • Multi-Level Battery Voltage Detector Support. Back-Light & Buzzer Sound Driver. • Parameters Displayed: Dc Resistance, Serial Inductance, Parallel Inductance, Serial Capacitance, Parallel Capacitance, Serial Resistance, Parallel Resistance, Phase Angle, Equivalence Serial Resistance, Dissipation Factor, Qqquality Factor. Capacitor:- 2.5Mfd, 2.25Mfd/400Volt-1No. Each. Inductor:- 10Mh, 4.7Mh. -1No. Each. , Test The Pn Junction Diode Using Digital Multimeter And Finding Out Their V-I Characteristics In Forward Bias. Ammeter:15Ma/150Ua Dc Panel Mount-1No., Voltmeter: 3V/30V Dc Panel Mount-1No. Power Supply: Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No. Components Are Fixed On The Kit. Silicon Diode _1N4007)-1No., Germanium Diode-1No.,Two Different Voltage Zener Diode-1No.,Voltage Control Through Potentiometer-1No. Digital Multimeter Meeting Iec1010standard. Ce , Identify The Terminals Of A Transistor Using Digital Multimeter And Calculate Gain In Ce Mode Transistor. Transistor- Pnp And Npn Type-1No. Each., Ammeter:- 15Ma/150Ua Dc Panel Mount-1No., Voltmeter:- 3V/30V Dc Panel Mount-1No. Power Supply:- Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No., Digital Multimeter , Realization Of Truth-Table Og Different Logic Gates(Ttl) And Verification Of De-Morgans Theorem . Fixed Dc Power Supply Of 5 V /250 M A. . One Output Indicator For Taken The Observations And Two Toggle Input Selectable Switches For Selects 0 And 1 Logics. . Or Gate, Not Gate, And Gate, I C’ S Are Mounted On The Front Panel. . User Manual And Connecting Leads Are Also Provided With This Instruments.
Contract Date: Dec 30, 2024 Contract Value : 51.88 Lakh
Government Departments No of Bidders 36
West Bengal View Result →
6.
Defence #6886994 AOC
Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date: Feb 25, 2025 Contract Value : 47.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
7.
Public Administrative Department #6093567 AOC
Bids Are Invited For Gm Survey Meter Analogue Total Quantity : 303
Contract Date: Ref. Documents Contract Value : 59.08 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
9.
Educational and Research Institute #4925815 AOC
Bids Are Invited For Analogue Compression Testing Machine , Vee Bee Consistometer , Curing Tank , Losangeles Abrasion Testing Machine , Cube Moulds , Steel Trays , Slump Test Apparatus , Flakiness Index Test Gauge , Elongation Index Test Gauge , Rebound Hammer Test Apparatus , Digital Balance , Vicat Apparatus, With Dashpot , Laboratory Oven , Standard Sieve Set For Coarse Aggregate , Standard Set Of Sieve For Fine Aggregate , Spade , Trowel , Cement Mortar Cube Vibrator , Motorized Sieve Shaker , Compaction Factor Test Apparatus , Bulk Density Apparatus , Measuring Cylinders , Thermometer , Vibrating Table , Steel Trolley , Rockwell Hardness , Abrasive Cut Off Machine , Polishing Machines , Liquid Limit Apparatus , Plastic Limit Apparatus , Pycnometer , California Bearing Ration Test Apparatus ( Motorised ) , Core Cutter , Sand Replacement Test Apparatus , Standard Proctor Test Apparatus , Falling Head Permeability Test Apparatus , Unconfined Compression Test Apparatus , Direct Shear Test Apparatus , Vane Shear Test Apparatus , Hand Operated Auger Boring Test Apparatus And Sampling , Universal Testing Machine ( Utm ) , Consolidation Apparatus , Bitumen Penetrometer , Ring And Ball Apparatus , Aggregate Crushing Value Apparatus , Aggregate Impact Testapparatus , Ductility Test Of Bitumen Apparatus , Centrifuge Extractor , Spring Testing Machine , Metric Chain , Measuring Tape / Metallic Tape , Optical Square. , Cross Staff. , Ranging Rods , Offset Rods , Arrows , Prismatic Compass With Tripod Stand , Surveyor Compass With Tripod Stand , Dumpy Level , Levelling Staff , Plane Table Survey Equipments , Electronic Theodolite ( Including All Standard Accessories ) , Total Station , Tilting Level. , Tangent Clinometer. , Abney Level , Wooden Pegs , Wooden Mallets , Automatic Level , Dissolved Oxygen Meter , Total Dissolved Solids Meter , Residual Chlorine Meter , Conductivity Meter , Digital P H Meter , Flocculator ( Jar Test Apparatus ) , Water Meter , Pipe Fittings , Dye For Threading , Simple Manometer , Differential Manometer , Meta Centric Height Apparatus , Building Construction Models , Water Supply & Waste Water Engineeringmodels Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 48.82 Lakh
Boards / Undertakings / PSU No of Bidders 9
Jammu And Kashmir View Result →
10.
Educational and Research Institute #3659564 AOC
Repairs And Maintenance Contract Of Electrical And Telephone Work Of Non - Residential Buildings At Savitribai Phule Pune University ( 2023-2024 ) .- 1 Supplying & Erecting 2 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S / Ws 113C Laid In Provided Pvc Casing Capping / Conduit As Per Specification No. Wg-Tw 2 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected. 3 Supplying And Erecting Modular Type Telephone Socket One Gang With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connectionscomplete 4 Supplying, Erecting & Commissioning 10 Pair Module For Connection & Disconnection Of Telephone Cable As Per Specification No. Wg-Tw 5 Supplying, Erecting & Commissioning 20 Pairs Fr Junction Box With Mouldedplastic Enclosure As Per Specification No. Wg-Tw 6 Supplying, Erecting & Commissioning 30 Pairs Fr Junction Box With Moulded Plastic Enclosure As Per Specification No. Wg-Tw 7 Supplying, Erecting & Commissioning 40 Pairs Fr Junction Box With Moulded Plastic Enclosure As Per Specification No. Wg-Tw 8 Supplying And Installing Cat-6 Cable Suitable For Networking As Per Specification No. Wg-Coc / Nc 9 Supplying And Fixing 1 M Utp Patch Cord Of Cat 6 Type In Position As Perspecification No. Wg-Coc / Pc 10 Supplying And Fixing 3 M Utp Patch Cord Of Cat 6 Type In Position As Per Specification No. Wg-Coc / Pc 11 Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No.Wg-Nas / Utpc. 12 Supplying And Fixing Tool-Less Io ( Ethernet ) Flush / Surface Type In Provided Modular Box As Per Specification No. Wg-Nas / Io 13 Supplying And Fixing Tool-Less Shutter Keystone Jack ( Rj-45 ) In Provided Patch Panel Complete As Per Specification No. Wg-Nas / Kj 14 Supplying, Installing, Testing & Commissioning Push Button Telephone Instrument Desk Top Unit As Per Specification Complete 15 Supplying, Installing, Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id & Speaker Unit As Per Specification Complete. 16 Supplying, Installing, Testing & Commissioning Analogue Type 1+1 Basic Twin Instrument Telephone Set Without Display Complete 17 Supplying, Installing, Testing & Commissioning Analogue Type 1+1 Cordlesstwin Instrument Telephone Set With Speaker Phone And Display Complete 18 Supplying & Erecting 20 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Coloursheathed With Fr Pvc, Conforming To Itd Specification S / Ws 113C Laid In Provided Pvc Casing Capping / Conduit As Per Specification No. Wg-Tw 19 Supplying & Erecting 10 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Coloursheathed With Fr Pvc, Conforming To Itd Specification S / Ws 113C Laid In Provided Pvc Casing Capping / Conduit As Per Specification No. Wg-Tw 20 Supplying And Erecting Rj-11 Connector 21 Supplying And Erecting Line Cord For Telephone 22 Supplying And Erecting Coil Cord For Telephone 23 Supplying And Erecting Panasonic Make Cordless Telephone Handset With Display, Caller Id And Speaker Etc. Complete. 24 Supplying And Erecting Hms Pvc Conduit Frls Grade 20 Mm Dia. With Necessary Accessories In Wall / Floor With Chiselling Appropriately As Per Specification No: Wg-Ma / Cc. 25 Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Necessary Accessories In Wall / Floor With Chiselling Appropriately As Per Specification No: Wg-Ma / Cc. 26 Supplying And Erecting Hms Pvc Conduit Frls Grade 32 Mm Dia. Withnecessary Accessories In Wall / Floor With Chiselling Appropriately As Per Specification No: Wg-Ma / Cc. 27 Supplying And Erecting 20Mm Dia. Corrugated Flexible Polypropylene Conduit 28 Supplying And Erecting 25 Mm Dia. Corrugated Flexible Polypropylene Conduit 29 Supplying And Erecting Hms Pvc Conduit Frls Grade 20 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 30 Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 31 Supplying And Erecting Hms Pvc Conduit Frls Grade 32 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 32 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 20 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 33 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 34 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 32 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 35 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 40 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 36 Supplying And Erecting Pvc Box Trunking Of Size 50X16 / 20 Mm. With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Box. 37 Supplying And Erecting Pvc Box Trunking Of Size 50X50 Mm. With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Box. 38 Supplying And Erecting Pvc Slotted Box Trunking Of Size 25X25 Mm. With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Slbox. 39 Supplying And Erecting Pvc Slotted Box Trunking Of Size 45X30 Mm. With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Slbox. 40 Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 41 Supplying And Erecting Mains With 1X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 42 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 43 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 44 Supplying And Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places.As Per Specification No: Wg-Ma / Bw 45 Supplying And Erecting Mains With 2X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places.As Per Specification No: Wg-Ma / Bw 46 Supplying And Erecting Mains With 2X10 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Placesas Per Specification No: Wg-Ma / Bw 47 Supplying And Erecting Mains With 4X16 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Placesas Per Specification No: Wg-Ma / Bw 48 Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1 Sq.Mm ( 32 No. X 0.20Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltagegrade Up To 1.1 Kv 49 Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltagegrade Up To 1.1 Kv 50 Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm ( 50 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv 51 Supplying And Erecting Pvc Insulated Pvc Round Sheathed 4 Sq.Mm ( 56 No. X 0.30 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv 52 Point Wiring For Light / Bell Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg Pw / Cw 53 Point Wiring For Ceiling Fan Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg Pw / Cw 54 Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Perspecification No Wg-Pw / Sw 55 Point Wiring For Light / Bell / Exhaust Fan In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg Pw / Sw. 56 Point Wiring For Ceiling Fan In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing Andrequired Accessories As Per Specification No: Wg-Pw / Sw 57 Point Wiring For Independent Plug In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 58 Point Wiring For Light / Bell Hybrid Type ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg Pw / H 59 Point Wiring For Ceiling Fan ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Hw 60 Point Wiring For Light / Bell / Exhaust Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 61 Point Wiring For Ceiling Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 62 Point Wiring For Independent Plug In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 63 Secondary Point Wiring For Additional Light / Bell Point, Concealed Type Inmin 20 Mm Frls Grade Pvc Conduit With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires With Required Accessories As Per Specification No: Wg-Pw / Cw 64 Secondary Point Wiring For Additional Light / Bell Point In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire With Required Accessories As Per Specification No: Wg-Pw / Sw 65 Wiring For Plug On Board With Switch Socket Surface / Concealed Type, Copper Wiring And Earthing And With Modular Accessories As Per Specification No: Wg Pw / Cw 66 Dismantling The Existing Light, Fan, Bell, Clock, Independent Plug Point, Wiring Including Circuit Mains Of All Types Along With Accessories Etc. Complete As Per Specification No: Wg-Dm / Pw 67 Dismantling The Existing Telephone / Lan / Wan / Tv Cables And Wires Of All Sizes Along With Casing-Capping / Conduit Complete As Per Specification No: Wg-Dm / Pw 68 Dismantling The Existing Aluminium / Copper Mains, Sub-Mains Wiring Upto 10 Sq.Mm. Along With Accessories Etc. Complete As Per Specification No: Wg-Dm / Pw 69 Supplying And Erecting Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 70 Supplying And Erecting Modular Type Switch 16A Duly Erected On Provided Plate And Box With Wiring Connections Complete 71 Supplying And Erecting Modular Type Bell-Push 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 72 Supplying And Erecting Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 73 Supplying And Erecting Modular Type D.P. Switch 32A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 74 Supplying And Erecting Modular Type 3 Pin 6A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 75 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 76 Supplying And Erecting Modular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete 77 Supplying And Erecting Modular Type Blanking Plate One Module, Duly Erected On Provided Plate & Box. 78 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected 79 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected. 80 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected. 81 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected. 82 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected. 83 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. 84 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected. 85 Supplying And Erecting Pvc Surface Modular Switch Box With Doublemounting Plate For 16 / 18 Module Duly Erected. 86 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 1 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match Th Background. 87 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background 88 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 89 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 90 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected Flush To Wall With Requiredchiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 91 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 8 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 92 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 93 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 16 / 18 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. 94 Supplying And Erecting White Footlight With 4 Modules Concealed Modular Box And Led Lights With Cover Complete Erected On Wall / Flush To Wall With Necessary Chiselling In Wall And Finishing With Cement And Mortar / Pop As Per Required And Duly Connected. 95 Supplying And Erecting Led Square / Circular Max. 7W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 770 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5% Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. 96 Supplying And Erecting Led Square / Circular Max. 11 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1200 Lumens, Min. Efficacy Of110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty 97 Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. 98 Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty 99 Supplying And Erecting Led Square / Circular Max. 25 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2750 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. 100 Supplying And Erecting Led Panel Light ( 600Mm X 600Mm ) Max. 35 W Having Crca Powder Coated Housing, Polystyrene Diffuser Having System Lumens Output Of Min 4200 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Yearswarranty. 101 Supplying And Erecting Led Strip Light 5M Length Max. 45 W Ip20 Class Having Minimum Lumens Output Of 800 Lumens / M, Min. Efficacy Of 90 Lumen / W, Cri>80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd<10%, P.F. >0.95, Operating Range Of 230-270V, Life Class Of 30, 000 Hrs. At L70b50, Including Driver With 1 Year Warranty. 102 Supplying And Erecting Led Strip Light 5M Length Max. 95 W Ip20 Class Having Minimum Lumens Output Of 1600 Lumens / M, Min. Efficacy Of 90 Lumen / W, Cri>80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd<10%, P.F. >0.95, Operating Range Of 230-270V, Life Class Of 30, 000 Hrs. At L70b50 Including Driver With 1 Year Warranty. 103 Supplying And Erecting Anodized Aluminium Corridor / Passage / Mirror Light Led Fitting ( 2 Feet ) Max. 12W With High Transitivity Diffuser With Min. System Lumens Output Of 1200 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple< 5%, Thd<10%, P.F. >0.95, Operating Range Of 200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. 104 Supplying And Erecting Crca Powder Coated Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 17W With High Transitivity Diffuser With System Lumens Output Of Min. 2000 Lumens , Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Ripple< 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. 105 Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22W With High Transitivity Diffuser With System Lumens Output Of Min.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri> 80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple< 5%, Thd<10%, P.F. >0.95, Operating Range Of 200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. 106 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 107 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 108 Supplying And Erecting Integrated Led Street Light Fitting 85-90W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 9300 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Drivercomplete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 109 Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Boutput Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 110 Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With Ushaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 111 Supplying & Erecting 3W, 230V Integral Type Led Lamp Suitable For B-22 / E 27 Base. 112 Supplying & Erecting 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 113 Upplying & Erecting 14W, 230V Integral Type Led Lamp Suitable For B-22 / E 27 Base. 114 Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E 27 Base. 115 Supplying And Erecting Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block / Sunmica Block Of Suitable Size. 116 Supplying And Erecting Electronic Type Driver For Indoor Led 5W-9W Fixtures Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 117 Supplying And Erecting Electronic Type Driver For Indoor Led 10W-18W Fixtures Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 118 Supplying And Erecting Electronic Type Driver For Indoor Led 19W-24W Fixtures Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 119 Supplying And Erecting Electronic Type Driver For Indoor Led 25W-40W Fixtures Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 120 Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘ G.I. Pipe 1.2 M. In Total Length Complete As Per Specification No. Fg-Bkt / Wb 121 Supplying And Erecting Street Light Wall Bracket Made From 40 Mm. Dia ‘ G.I. Pipe 1.2 M. In Total Length Complete As Per Specification No. Fg-Bkt / Wb 122 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W 45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 123 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W 75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 124 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W 100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 125 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W 150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10% 126 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 900 / 1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 127 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 128 Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 129 Supplying Pedestal Fan 400 Mm. 230 Volts 50 Cycles Oscillating Type Complete With Guard And Regulator 3 Meter. Of Flexible Wire And Hand Shield Type 3 Pin Plugtop 130 Supplying And Erecting Cabin Fan Of A.C. 230 V. 50 Cycles 400 Mm. Sweep Complete With Necessary Brackets For Fixing Cabin Fans, Wire Etc 131 Supplying And Erecting Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 225Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected, Complete 132 Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. 133 Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 375 / 380 Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg Fn / Exf 134 Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 450 Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg-Fn / Exf 135 Supplying And Erecting Energy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200Mm Complete Erected In Position As Per Specification No. Fg-Fn / Cf 136 Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm, Max. Energy Consumption Of 28W Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speed Regulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Control Pcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf 137 Supplying And Erecting Condenser 2.5 Micro Farad For Ceiling Fan 138 Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. 139 Supplying And Erecting Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 140 Supplying And Erecting Fan Hook Of 10 Mm. M.S. Round Bar Grouted In Rcc Slab With Making The Site As Original. 141 Supplying And Erecting ‘B’ Class G.I .Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 142 Supplying And Erecting Storage Type Water Heater 25 Litres Capacity Having Standing Loss <0.511Kwh / 24Hour / 45°C, High Impact Resistance Engineering Plastic Body With Anti Corrosive High Grade Steel Inner Tank, Heating Element Having Hard Water & Corrosion Protection, With Minimum 3 Safety Protections ( I.E. Thermostat & Thermal Function Cut-Out, Valve ) With Total Pressure 8 Bar Withstanding Capacity Duly Tested And Marking Sr. No. And Date Of Erection Complete. Specification No. Ap-Wh / Stwh 143 Supplying And Erecting Midget Type 3.0 Litres Instant Type Water Heater Of Rustproof & Shockproof Abs Plastic Body, High Grade Ss Inner Tank & 3Kw Heating Element With Corrosion & Hard Water Protection, With Minimum 3Safety Protections ( I.E. Thermostat & Thermal Cut-Out, Function Valve ) Complete With 6.5 Bar Pressure Withstanding Capacity 230 / 250V, 50Hz, A.C. Supply With Inlet And Outlet, With 3 Core Pvc Flexible Copper Wire Leads Duly Tested And Marking Sr. No. And Date Of Erection Complete. 144 Supplying, Erecting, Testing & Commissioning Of Self Contained Drinking Water Coolers With ( Non - Cfc Refrigerant ) Energy Efficient Compressors Of : 1 ) Minimum Cooling Capacity - 20 Ltrs. / Hour. 2 ) Storage Capacity - 40Ltrs. 3 ) Stainless Steel Body. 4 ) Consumption In Watt - Less Than 850 Watt. 5 ) Make - Bluestar / Voltas / Usha. 145 Supplying, Erecting, Testing & Commissioning Of Self Contained Drinking Water Coolers With ( Non - Cfc Refrigerant ) Energy Efficient Compressors Of : 1 ) Minimum Cooling Capacity -120 Ltrs. / Hour. 2 ) Storage Capacity - 150 Ltrs. 3 ) Stainless Steel Body. 4 ) Consumption In Watt - Less Than 1700 Watt. 5 ) Make - Bluestar / Voltas / Usha. 146 Supply & Erecting Water Purifiers With Pre- Filter Of Specs : 1 ) Choke - Copper. 2 ) Uv Tube - 16 Watt Capacity ( Philips ) . 3 ) Pre Carbon Filter. 4 ) Post Carbon Filter. 5 ) Sediment Filter. 6 ) Minimum Output Purified Water - 200 Ltrs. / Hour. 7 ) Make - Bluestar / Eureka / Kent / Ao Smith.. 147 Supplying And Erecting 12V / 80Ah To 88Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. 148 Supplying And Erecting 12V / 100Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. 149 Supplying And Erecting 12V / 150Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete 150 Supplying And Erecting 12V / 42Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete 151 Supplying And Erecting 12V / 100Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete 152 Supplying And Erecting Fully Automatic Line Voltage Stabilizer Buck And Boost Type For Operation On Input Voltage 160-270V And Output Voltage 200-250V Ratedfor 3Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output And With 3 Core Copper Flexible Cord And 3 Pin 6 / 16A Plugtop With Overload & Short Circuit Protection Complete. 153 Supplying And Erecting Fully Automatic Line Voltage Stabilizer Buck And Boost Type For Operation On Input Voltage 160-270 V And Output Voltage 200-250V Ratedfor 5Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output And With 3 Core Copper Flexible Cord And 3 Pin 6 / 16A Plugtop With Overload & Short Circuit Protection Complete . 154 Supplying, Erecting & Marking Spmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 155 Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short -Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 156 Supplying, Erecting & Marking Spmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 157 Supplying, Erecting & Marking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 158 Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Perspecification No. Sw-Swr / Mcb 159 Supplying, Erecting & Marking Dpmcb 6 A To 32 A, B-Series With Rated Short -Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 160 Supplying, Erecting & Marking Dpmcb 40A To 63A, C-Series With Rated Short -Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 161 Supplying, Erecting & Marking Dpmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Perspecification No. Sw-Swr / Mcb 162 Supplying, Erecting & Marking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 163 Supplying, Erecting & Marking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 164 Supplying, Erecting & Marking Fpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 165 Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 166 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , Spmcb Of 4 Ways / Phase ( 12 Poles ) , With Door, 1.2Mm Thickness, Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame ( Horizontal Busbartype ) As Per Specification No. Sw-Swr / Mcbdb 167 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , Spmcb Of 8 Ways / Phase ( 24 Poles ) , With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame ( Horizontal Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb 168 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , Sp / Tp Mcbs Total 4 Ways / 12 Poles, With Door, 1.2Mm Thickness Surface / Flushmounted, Ip 43 Protection On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb 169 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , Sp / Tp Mcbs Total 8 Ways / 24 Poles, With Door, 1.2Mm Thickness Surface / Flushmounted, Ip 43 Protection On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb 170 Supplying And Erecting Single Pole And Neutral Distribution Board ( Spndb ) , With 2 Ways For Incoming And 6 Ways ( 6 Poles ) For Outgoing Sp Mcbs, Withdoor, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb 171 Supplying And Erecting Single Pole And Neutral Distribution Board ( Spndb ) , With 2 Ways For Incoming And 10 Ways ( 10 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb 172 Supplying & Erecting Crca Sheet Metal One Way Enclosures Of 1.2Mm Thickness Suitable For Dp Mcb / Tp Mcb / Fp Mcb / Rccb / Rcbo Complete Erected On Angle Iron / Gi Frame. 173 Supplying And Erecting Blanking Plate Of Suitable Size On Mcbdb. 174 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , 3 Pole / 4 Pole Mccb As Incomer & Outgoing Sp Mcb ( 12 Poles ) Or Tp Mcb Of 4 Ways ( 12 Poles ) , With Door, 1.2Mm Thickness, Surface / Flush Mounted, On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb1 175 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , 3 Pole / 4 Pole Mccb As Incomer & Outgoing Sp Mcb ( 24 Poles ) Or Tp Mcb Of 8 Ways ( 24 Poles ) , With Door, 1.2Mm Thickness, Surface / Flush Mounted, Oniron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb1 176 Providing & Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb 177 Providing & Erecting 3 Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw Swr / Mccb 178 Providing & Erecting 3 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka ( Ics=100% Of Icu ) Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb 179 Supplying, Erecting & Commissioning 2 Pole Rccb 16 / 25A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb 180 Supplying, Erecting & Commissioning 2 Pole Rccb 63A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb 181 Supplying, Erecting & Commissioning 4 Pole Rccb 40A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb 182 Supplying, Erecting & Commissioning 4 Pole Rccb 63A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb 183 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 25 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 184 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 50 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 185 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 70 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 186 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 95 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 187 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 120 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 188 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 150 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 189 Cable Fault Detection For All Types Of Lt Underground Cable From 16Sq. Mm. To 400 Sq. Mm. By Acoustic Method By Using Surge Wave Tester & Surge Wave Receiver ( Duo Phone ) Up To 250 Meter Length Cable With Recording Results & Submission Of Test Reports. 190 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 25 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 191 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 4 Sq. Mm. Copperconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 192 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 193 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 194 Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For Ltxlpe Armoured Cable 25 To 50 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt / Lt 195 Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For Ltxlpe Armoured Cable 70 To 95 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt / Lt 196 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete 197 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 75 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 198 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 90 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 199 Making Trench In Soft Soil Having 0.9M Depth And Minimum 0.3 M Width Asper Is For Laying Provided Cables Of Voltage Range 3.3 Kv To 11 Kv Complete Asper Specification No. Cw-Exn-Ctr 200 Making Trench In Hard Murum / Tar Road Having 0.9 M Depth And Minimum 0.3Mtr Width For Laying Provided Cables Of Voltage Range 3.3 Kv To 11 Kv Complete As Per Specification No. Cw-Exn-Ctr 201 Supplying And Erecting Bus Bar Chamber Triple Pole With Neutral With Four Aluminium Bars, 500V, 100A Having 15Mm ( Width ) X 3 Mm ( Thickness ) , With99.9 % Aluminium Purity As Per E91e Grade & Current Density 0.8 A Persq. Mm. Compliance To Is 5082 And Enclosure Fabricated With 16 Swg Crca Sheet And Epoxy Paint, With Suitable Number Of Ways And With Smc / Dmc Insulators And Accessories Of Suitable Rating Complete As Per Specification No. Cp Bb 202 Supplying And Erecting Bus Bar Chamber Triple Pole With Neutral With Four Copperbars, 500V, 100A Having 10Mm ( Width ) X 1.6 Mm ( Thickness ) , With 99.9 %Copper Purity As Per E91e Grade & Current Density 1.6 A Per Sq. Mm. Compliance To Is 5082 And Enclosure Fabricated With 16 Swg Crca Sheet And Epoxy Paint, With Suitable Number Of Ways And With Smc / Dmc Insulators And Accessories Of Suitable Rating Complete As Per Specification No. Cp-Bb 203 Supplying And Erecting Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Kwh, Kvah, V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva ) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 204 Supplying And Erecting Static Energy Meter With 3 X 240V 50 Hz. Ac Supply 10 To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Trivector, V, I, Kw, Pf, Hz, Last Month History Of Kwh And Md In Kw ) With Special Features Like Tod, Tamper Logging, Optical Communication Port & Display In Absence Of Power & With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 205 Supplying And Erecting Lt Ct Multifunction Dlms Compliance Energy Meter Of Accuracy Of Class 0.5 , 3X240v, 50 Hz With Optical & Rs 232 Port, Backlit Lcd, Measure & Display Trivector Energy, Load Survey, Tod, Tamper Detection & Logging, Power On / Off Events, Instantaneous Parameters Of Rating 1 / 5 A With Display In Absence Of Power Complete With Zero Adjustment & Test Certificate From Manufacturer Erected On Provided M.S. Box And Connected To Cts. 206 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 230V, Single Phase 50 Cycles A.C. Supply Of 1.125 Kw / 1.5Hp With Discharge 198 / 50 Litres Per Minute ( Lpm ) ) For Head Of15 / 37.5 M & 40 Mm Suction / 32 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 207 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 230V, Single Phase 50 Cycles A.C. Supply Of 1.5 Kw / 2 Hp With Discharge 600 / 140 Litres Per Minute ( Lpm ) For Head Of 8 / 22 M & 50 Mm Suction / 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 208 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 415V, Three Phase 50 Cycles A.C. Supply Of 1.5 Kw / 2 Hp With Discharge 600 / 140 Litres Per Minute ( Lpm ) For Head Of 8 / 22 M And 50 Mm Suction / 40 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 209 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 415V, Three Phase 50 Cycles A.C. Supply Of 2.25 Kw / 3 Hp With Discharge 720 / 165 Litres Per Minute ( Lpm ) For Head Of 12 / 26 M And 65 Mm Suction / 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 210 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 415V, Three Phase 50 Cycles A.C. Supply Of 2.25 Kw / 3 Hp With Discharge 600 / 110 Litres Per Minute ( Lpm ) For Head Of 13 / 43 M And 65 Mm Suction / 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 211 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 415 V, Three Phase 50 Cycles A.C. Supply Of 3.75 Kw / 5 Hpwith Discharge 420 / 120 Litres Per Minute ( Lpm ) For Head Of 18 / 51 M And 65 Mm Suction / 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp 212 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 1.125 Kw / 1.5 Hp With 230 V, 50 C / S Ac Supply Suitable For 100 Mm Dia. Borewell Suitable For 10 To 50 Lpm Discharge At 150 To 40 M Head & Discharge & Delivery Pipe Of Size-32 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp 213 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 1.5 Kw / 2 Hp With 230 V, 50 C / S Ac Supply Suitable For 100 Mm Dia. Borewell Suitable For 30 To 140 Lpm Discharge At 85 To 32 M Head & Discharge & Delivery Pipe Of Size-40 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp 214 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 2.25 Kw / 3 Hp With 415 V, 50 C / S Ac Supply Suitable For 100 Mm Dia. Borewell Suitable For 10 To 240 Lpm Discharge At 74 To 25 M Head & Discharge & Delivery Pipe Of Size-50 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp 215 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Suitable For Erection On Open Well Of 2.25 Kw / 3 Hp With 415 V 50 C / S. A.C. Supply, Having Delivery Head From 27 To 9 M And Discharge From 300 To 660 Litres. Per Minute & Pipe Of Suction 65Mm / Delivery 50 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp 216 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Suitable For Erection On Open Well Of 3.75 Kw / 5 Hp With 415 V 50 C / S. A.C. Supply, Having Delivery Head From 43 To 11M And Discharge From 120 To 840 Litres. Per Minute & Pipe Of Suction 65Mm / Delivery 50 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp 217 Supplying And Erecting Minimum Three & Above Star Rated Submersiblepump Set Suitable For Erection On Open Well Of 5.625 Kw / 7.5 Hp With 415 V 50 C / S. A.C. Supply, Having Delivery Head From 36 To 14M And Discharge From 225 To 1680 Litres. Per Minute& Pipe Of Suction 75 Mm / Delivery 65 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp 218 Supplying And Erecting Minimum Three & Above Star Rated 1 Phase, 230 V, 50 Hz, Submersible Pump Set Of 0.75 Kw / 1Hp For Erection On Open Well, Pump Having Delivery Head From 30 To 15 M And Discharge From 30 To 270 Litres. Per Minute & Pipe Of Suction 32 Mm / Delivery 25 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp 219 Supplying And Erecting Minimum Three & Above Star Rated 1 Phase, 230 V, 50 Hz, Submersible Pump Set Of 1.5 Kw / 2Hp Suitable For Erection On Open Well, Pump Having Delivery Head From 29 To 7 M And Discharge From 30 To 600 Litres. . Per Minute & Pipe Of Suction 50 Mm / Delivery 50 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp 220 Supplying & Erecting D.O.L Starter Suitable For 250 V, Single Phase 50 Cycles With Overload Element With Necessary Materials And Connected To Supply Up To 3 H.P. 221 Supplying & Erecting D.O.L Starter Suitable For 415 V, 3 Phase 50 Cycles With No Volt Coil And Overload Element With Necessary Materials And Connected To Supplyup To 7.5 H.P. 222 Supplying & Erecting Automatic Control Panel For 1 Ph, 230 Volt, A.C. Submersible / Centrifugal Pump Set Up To 3 Hp Consisting Of Dol Starter Of Suitable Relay Range S.P.P., Combined Ammeter / Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. 223 Supplying & Erecting Automatic Control Panel For 3 Phase , 415 Volt, A.C, Submersible / Centrifugal Pump Set Up To 7.5 Hp Consisting Of Dol Starter Having Relay Range 9-14 Amp, S.P.P., Combined Ammeter / Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phase Reversal, Phase Imbalance Etc . 224 Supplying & Erecting Pressure Booster Pump, Single Phase, 50C / S, A.C. Supply Of 0.75 Kw / 1 H.P., With Discharge Of 480 To 13 Lpm For 10 To 50 Mtr Head & 25 Mm Suction / 25 Mm Delivery Pipe, For Domestic Pressure Boosting Applications. 225 Supplying & Erecting Pressure Booster Pump, Single Phase, 50C / S, A.C. Supply Of 1.125 Kw / 1.5 H.P., With Discharge Of 480 To 31 Lpm For 10 To 50 Mtrhead & 25 Mm Suction / 25 Mm Delivery Pipe, For Domestic Pressure Boosting Applications. 226 Dismantling The Existing Monoblock / Open Well Submersible Water Pump Set Centrifugal Type Without Pipeline Complete And Making The Site Clear 227 Dismantling The Existing Submersible Pump With Pvc Pipeline 228 Supplying & Erecting Flat Flexible 3 Core 2.5 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. 229 Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete 230 Supplying & Erecting Flat Flexible 3 Core 6 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. 231 Supplying & Erecting Flat Flexible 3 Core 1.5 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. 232 Supplying & Erecting Flat Flexible 3 Core 10 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. 233 Supplying & Erecting Water Level Controller 230 / 415 V, A.C. , Two Way Under Ground Tank Operation Only 234 Supplying & Erecting Water Level Controller 230 / 415 V, A.C. , Four Way Under Ground & Over Head Tank Operation Only. 235 Supplying & Erecting Water Level Controller 230 / 415 V, A.C. , Four Way Under Ground & Over Head Tank Operation With Sensor Float Switch And Wriring And All Other Material Required Complete.. 236 Rewinding Of Electric Motor Above 1 Hp Upto 2 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year 237 Rewinding Of Electric Motor Above 2 H.P. Upto 3 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year 238 Rewinding Of Electric Motor Above 3 H.P.Upto 5 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year 239 Rewinding Of Electric Motor Above 5 H.P. Upto 7.5 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year 240 Rewinding Of Submersible Pump Motor In Borewell Of All Types And Makes Up To And Including 5 Hp With Coated Copper Wires & Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed, H.P. And No Load Consumption & Guarantee For One Year 241 Rewinding The Motor Of The Ceiling Fan 1200 Mm / 1400 Mm Of All Types , Makes And Over Hauling Including Minor Repairs Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. & Testing For Original Speed And Consumption With Guarantee For One Year. 242 Replacing The Existing Driving End Bearing Of Original Make For Electric Motor A.C Single Phase / 3 Phase 1.5 H.P. To 2 Hp Of All Types With Required Alignment Of The Shaft And Testing The Same. 243 Replacing The Existing Driving End Bearing Of Original Make For Electric Motor A.C Single Phase / 3 Phase 3 Hp To 7.5 Hp Of All Types With Required Alignment Of The Shaft And Testing The Same.. 244 Replacing The Existing Nondriving End Bearing Of Original Make For Electric Motor A.C Single Phase / 3 Phase 1.5 H.P. To 2 Hp Of All Types With Required Alignment Of The Shaft And Testing The Same. 245 Replacing The Existing Nondriving End Bearing Of Original Make For Electric Motor A.C Single Phase / 3 Phase 3 Hp To 7.5 Hp Of All Types With Required Alignment Of The Shaft And Testing The Same. 246 Supplying And Installation Of 24 Ltrs, 10 Bar Pressure Tank For Pressure Pump. 247 Supplying And Installation Of Pressure Switch ( Dymfos Switch ) For Pressure Pump. 248 Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 249 Providing Earthing With Copper Earth Plate Size 30 X 30 X 0.315 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 250 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep 251 Supplying, Installation And Testing Of Maintenance Free Earthing Comprising Of Electrode Of 17.2 Mm Diameter Low Carbon Steel With 250 Micron Molecularcopper Bonded Earthing Rod Of Length 3M Along With 25 Kg Carbon Based Environment Friendly Back Fill Ground Enhancing Compound Required To Fill Up The Excavated Earth With Required Quantity Complete, And Recording The Results Specification No. Ea-Mobi 252 Supplying And Erecting Copper Strip Of High Purity Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Copper Clamps Fixed On Wallpainted With Bituminous Paint With Joints Required. As Per Specification No. Ea Ep 253 Supplying And Erecting Gi Strip Of High Purity Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint With Joints Required. As Per Specification No Ea-Ep. 254 Supplying And Erecting Gi Wire Of High Purity Of Required Sizes Used For Earthing Or Any Other Purposes On Wall With Necessary G. I. Clamps Fixed On Wall / Cable / Conduit With Screws Complete. 255 Supplying And Erecting Gi Strip Of Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Insulating And Non-Corrosive Bond With Required Joints As Per Specificationno. Ea-Ep. 256 Supplying And Erecting Copper Strip Of Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Copper Clamps Fixed On Wall Painted With Insulating And Non-Corrosive Bond With Required Joints As Per Specification No. Ea-Ep. 257 Supplying & Erecting Conventional Spike Type Air Termination Suitable To Carry Lightning Stroke Made Up Of Heavy Gauge 40 Mm Dia Copper Pipe Of Standard Length With 5 Nos. Copper Spikes Fixed On Copper Ball As Air Terminals Duly Threaded In Copper Pipe Erected On Provided Foundation Complete. 258 Providing And Back Filling Ground Enhancing Compound 25 Kg Bag Complete. 259 Supplying And Erecting Mains With Wp 2 X 2.5 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 260 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 261 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 262 Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendant Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block / Pvc Junction Box. 263 Supplying And Erecting Adaptor For Lamp Holder 230 V.A.C. Supply 264 Supplying And Erecting 15M Vga Cord Low Voltage Grade To Be Laid In Provided Conduits And Terminating With Male / Female Vga Connectors Complete. 265 Supplying And Erecting 3M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete 266 Supplying And Erecting 5M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete 267 Supplying And Erecting 10M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete. 268 Supplying And Erecting 15M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete. 269 Supplying And Erecting 15M Audio Video Cord Low Voltage Grade As Per Specification With Required 3Rca X 3Rca Connector Complete. 270 Supplying, Installation, Testing And Commissioning Of Voip - Fxs 4 Port Gateway With Capability Of Proxy Peer To Peer Calling ( Minimum Waranty To Entire System Without Any Cost To University - 1 Year ) 271 Supplying, Installation, Testing And Commissioning Of Voip - Fxs 8 Port Gateway With Capability Of Proxy Peer To Peer Calling ( Minimum Waranty To Entire System Without Any Cost To University - 1 Year ) 272 Supplying, Installation, Testing And Commissioning Of Voip - Fxs 16 Port Gateway With Capability Of Proxy Peer To Peer Calling ( Minimum Waranty To Entire System Without Any Cost To University - 1 Year ) 273 Supplying, Installation, Testing And Commissioning Of Voip - Fxs 24 Port Gateway With Capability Of Proxy Peer To Peer Calling ( Minimum Waranty To Entire System Without Any Cost To University - 1 Year ) 274 Supplying, Installation, Testing And Commissioning Of Voip - Fxs 32 Port Gateway With Capability Of Proxy Peer To Peer Calling ( Minimum Waranty To Entire System Without Any Cost To University - 1 Year ) 275 Supplying And Erecting Slotted Angles, Frames Etc. For Panel Board Or Any Other Purposes Complete With Bending, Cutting, Drilling And Welding Complete Erected At The Position With Necessary Materials Duly Painted With One Coat Of Red Oxide And Two Coats Of Enamel Paint To Match The Switchgears Or As Per Directions By The Authority 276 Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. 277 Supplying And Erecting Gi Sheet 0.6 Mm ( 24 Swg ) Having Zinc Coating Of 275 Microns With Galvanization Process Compliance To Is 2629:1985 To Be Usedfor Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. And Painting With One Coat Of Red Lead Paint And 2 Coats Ofenamel Paint. 278 Providing & Erecting Hot Dipped Galvanised Ladder Type Cable Tray Manufactured From 16 Swg ( 1.6 Mm Thick ) Gi Sheet Of 150 Mm Width & 100 Mm Height Comprising All Required Standard Accessories 279 Dismantling The Existing Cables Of All Types & Size Up To 10 Sq Mm. 280 Dismantling The Existing Cables Of All Types & Size Above 10 Sq Mm Up To 50 Sq.Mm. 281 Dismantling The Existing Cables Of All Types & Size Above 50 Sq Mm. 282 Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 82.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50C / S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation + / - 5 %, With Performance Class G2 Andmaximum Fuel Consumption 14.0 Ltr / Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires / Cables, The Complete Set Enclosed Incomposite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 145 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg 283 Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 62.5 Kva Up To 82.5 Kvacapacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. 284 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking Forabnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internallyusing Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc 285 Carrying Out Servicing Of Dg Set From 62.5 Kva To 200 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internallyusing Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc 286 Hiring Charges For Supplying And Maintaining Temporary 415V, 50 Cycles Ac Generating Set 125 Kva Capacity With Voltage Regulation + / - 5 %, And Complete Set Enclosed In Composite Acoustic Enclosure To Restrict Sound Blevel Up To 75 Db At 1.0 M, With Necessary Fuel, Mains, Switchgears And Accessories Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification. 287 Hiring Charges For Supplying And Maintaining Temporary 415V, 50 Cycles Ac Generating Set 500 Kva Capacity With Voltage Regulation + / - 5 %, And Complete Set Enclosed In Composite Acoustic Enclosure To Restrict Sound Level Up To 75 Db At 1.0 M With Necessary Fuel, Mains, Switchgears And Accessories Complete With Continuous Running On Load / No Load As Per Requirements With Necessary Certificate From Electrical Inspector. 288 Supplying And Erecting V-Belt Of All Types And Lengths, Adjust Tension As Per Requirements From Generator Manufacturer Suitable For Dg Set Upto 100Kva 289 Supplying And Erecting V-Belt Of All Types And Lengths, Adjust Tension As Per Requirements From Generator Manufacturer Suitable For Dg Set From 125 Kva To 250 Kva 290 Topping Up New Lubricating Oil 15W / 40 Grade Of Approved Make As Per Is 13656 : 2014 291 Topping Up New Glycol Based Coolant 50 / 50 With Operating Range From 118°C To -37°C Of Approved Make 292 Supplying And Erecting Lub Oil Filter Element Along With Sealing Rings, Gasket Etc Complete Suitable For Dg Set Upto 62.5 Kva. 293 Supplying And Erecting Lub Oil Filter Element Along With Sealing Rings, Gasket Etc Complete Suitable For Dg Set From 82.5 Kva To 250 Kva 294 Supplying And Erecting Fuel Filter Along With Sealing Rings, Gasket, Primary Filter And Water Separator Etc Complete Suitable For Dg Set Upto 50 Kva 295 Supplying And Erecting Fuel Filter Along With Sealing Rings, Gasket, Primary Filter And Water Separator Etc Complete Suitable For Dg Set From 62.5 Kva To 125 Kva. 296 Providing / Conducting Complete Fire Audit Including Submission Of Fire Audit Report For The Whole Premises. 297 Supplying & Erecting Carbon Dioxide ( Co2 ) Fire Extinguisher Of 4.5 Kg. Capacity Cartridge Type Conform To Is 2878 / 15683 Complete Erected With Necessary Clamp Made From 50 X 6 Mm. M. S. Flat With Nut & Bolts Routed In Wall Complete. 298 Supplying 6 Amp. 3 Pin Plug Top Bakelite Type Of 230 V. A.C. Supply. 299 Supplying 16 Amp. 3 Pin Plug Top Bakelite Type Of 230 V. A.C. Supply. 300 Supplying And Erecting Shockproof 3 Pin Plug Socket 6A With Porcelain Base / Flush Type Erected On Filled Polypropylene Board Or Polished Thick Varnisheddouble Wooden Block / Folded Or Screwed Board With Top Of Either Wooden / 3 Mm Thick Hylam Sheet / 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. 301 Supplying And Erecting Shockproof 3 Pin Plug Socket 16A With Porcelain Base / Flush Type Erected On Filled Polypropylene ( Is:14772-2000 ) Board Or Polishedthick Varnished Double Wooden Block / Folded Or Screwed Board With Top Of Either Wooden / 3 Mm Thick Hylam Sheet / 4Mm Thick Plywood Pasted With 1.5 Mmthick Laminate With S M Screws And Duly Connected
Contract Date: Mar 28, 2024 Contract Value : 77.59 Lakh
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
11.
Drinking Water Supply and Sanitation #2311218 AOC
Tender For Augmentation Of Uwss Dausa With 1Year Defect Liability Period And 5 Years O&M After Defect Liability Period” - Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointingductileiron ( Di ) Isi Markedk-7Grades&Spipesas Per Is:8329-2000 ( Amendedup Todate ) , Withinternalcementmortar Lining Suitable For Potablewater With Rubber Ring ( Epdm ) Joints As Per Is: 5382-1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 2 100 Mm 3 150 Mm 4 200 Mm 5 250 Mm 6 300 Mm 7 350 Mm 8 400 Mm 9 450 Mm 10 600 Mm 11 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 ( Amended Upto Date ) With Necessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe Byelectro Fusion Welding Method, Including All Taxes , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) , Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earth Work ) .Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately.Supply May Be In Coil Or Straight Length In 6 M / 12 M.Hdpe Pe-80Pn-6 12 90Mm 13 110 Mm 14 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 ( Amended Upto Date ) With Necessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) , Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earth Work ) . Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately.Supply Of Pipe Shall Be In Straight Length In 6 / 12 M.Hdpe Pe-80Pn-6 15 125Mm 16 140Mm 17 160Mm 18 180Mm 19 200Mm 20 225Mm 21 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Trenches Of Required Width And Gradient For Laying And Jointing Of Pipe Line Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr. Including Required All Safety Provisions Etc.:All Kinds Of Soil 22 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Trenches Of Required Width And Gradient For Laying And Jointing Of Pipe Line Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Stacking Serviceable Material For Measurements And Disposal Of Unserviceable Material As Directed, With In A Lead Of 50 Mtr. Including All Safety Provisions Required .:Ordinary Rock 23 Providing And Fixing Of Flanged / Plain Ended Ms Specials Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixinginpositionatalllevel / Depths In Trenches Complete Includingall Taxes, Material, Labour, Inside Lining, Outside Coating, Testingandcommissioning Alongwithpipelineaspertechnicalspecifications Anddirection Of Engineer-In-Charge.Ms Pipespecialsupto600mmdia ( Withminimum5mmthickness Sheet ) 24 Providing And Fixing Of Flanged / Plain Ended Ms Specials Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixinginpositionatalllevel / Depths In Trenches Complete Includingall Taxes, Material, Labour, Inside Lining, Outside Coating, Testingandcommissioning Alongwithpipelineaspertechnicalspecifications Anddirection Of Engineer-In-Charge.Ms Pipe Specials Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 25 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Ci Double Acting Kinetic Air Valve With Isolating Sluice Valveof Approved Makes For Following Pressure Rating & Dia Complete, Confirming To Is: 14845-2000 ( Amendedupto Date ) And Of Following Specifications: Body , Cover And Cowl - Grey Cast Iron As Per Is:210- Fg 200 , Float - Stainless Steel Aisi 304 / Is: 3444 , Float Guide- Hbt1.Hp Orifice-Htb2 / Ss, Body Seat Ring - Leaded Tin Bronze / Ss .Seal Ring And Face Ring - Epdm / Nbr , Ends Flanged According To Is 6418, Fastners - Cs, Epoxy Paint Inside Outside Of Food Grade Safe For Drinking Water , Valves Including All Mateial, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work.Class Pn 1.0 26 50 Mm 27 80 Mm 28 100 Mm 29 150 Mm 30 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesstraight And Pocket Less Body Passage Of Approved Make Of Following Pressure Rating & Dia Complete, Confirfing To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , Epoxy ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steelinsersion Rubber Of Black Epdm 6Mm Thick . Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 31 80 Mm Dia 32 100 Mm Dia 33 125 Mm Dia 34 150 Mm Dia 35 200 Mm Hw 36 250 Mm Hw 37 300 Mm Hw 38 350 Mm With Gear 39 400 Mm With Gear 40 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirfing To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 41 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.6 ( Junction Valve ) 42 100 Mm Dia 43 150 Mm Dia 44 200 Mm Dia 45 250 Mm Dia 46 300 Mm Dia 47 350 Mm Dia 48 400 Mm Dia 49 450 Mm Dia 50 500 Mm Dia 51 600 Mm Dia. 52 Motorized Sluice Valves With Electric Actuator And Integral Starter Of Class Pn 1.6 53 100 Mm Dia 54 150 Mm Dia 55 200 Mm Dia 56 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvenised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 57 Class Pn 1.6, Manually Operated With Gear 58 400 Mm Dia 59 600 Mm Dia. 60 Class Pn 1.6, Motorised Operated 61 250 Mm Dia 62 300 Mm Dia 63 400 Mm Dia 64 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvenised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 65 Providing, Lowering, Aligning & Fixing In Position Di D / F Plunger Type Flow Control Valve Of Approved Make Of Following Pressure Rating & Dia Complete And Of Following Specifications:Body-Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or En-Js 1030, Plunger / Piston - Stainless Steel Aisi- 304 / Gr 1.4301, Piston Guides- Bronze Welded Overlay / Ss Shaft / Crank / Spindle- Stainless Steel Aisi- 420 / Gr 1.4021Body Seat Ring- Stainless Steel Aisi- 316 / 304 / Bronze Is:318- Ltb2 , Seal ( O- Ring / Quad Ring ) - Epdm / Nbr, Bearing Bush - Bronze Is:318- Ltb2, Slotted Cylinder / Strainer / Diffuser- Aisi- 420 / 304, Nut- Bolts - Ss, Face To Face- As Per Ansi B 16.1 / En 558-1 And Flange Ends Should Be As Per Ansi B-16.5, Class 150 And Class 300 / En-1092-2.Insersion Rubber Of Black Epdm 6Mm Thick , Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied Bothinside And Outside . Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning As Per Technical Specification & As Per Direction Of Engineer-In- Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Plunger Type Flow Control Valve 66 300Mm Dia 67 400Mm Dia 68 600Mm Dia 69 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Swing Type Non Return Valve Of Approved Make Of Following Pressure Rating & Dia Complete, Generally Confirming To Is: 5312 ( Part -1 ) / 2004 ( Amendedup To Date ) And Of Following Specifications: Body, Bonnet & Disc Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Is 5312 ( Part -1 ) :2004Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body, Cover And Disc Inside And Outside . Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs.Shaft Of Ss- Aisi- 410, Hinge Ss Aisi 316 / 410 , Bonnet Gasket Epdm , Bush- Brasswith Epdm / Nbr O Ring Seal Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvenised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Class Pn 1.6 70 100 Mm Dia 71 150 Mm Dia 72 200 Mm Dia 73 250 Mm Dia 74 400 Mm Dia 75 Construction Of Rcc Pillar For Following Size Of Air Valves Including Earthwork Excavation, Rcc M25 Grade For Base Slab, Vertical Pillar, Including Cost Of Steel Reinforcement , Gi ( Class-B ) / Ms Vertical Pipe, Form Work, Proper Curing Of Concrete Work Complete In All Respect As Per Standard Specifications And Drawings And As Directed By Engineer.Air Valve Pillarfor Airvalves Size Of 80Mmdia 76 Construction Of Rcc Pillar For Following Size Of Air Valves Including Earthwork Excavation, Rcc M25 Grade For Base Slab, Vertical Pillar, Including Cost Of Steel Reinforcement , Gi ( Class-B ) / Ms Vertical Pipe, Form Work, Proper Curing Of Concrete Work Complete In All Respect As Per Standard Specifications And Drawings And As Directed By Engineer.Air Valve Pillarfor Airvalves Size Of 100Mmdia 77 Construction Of Rcc Pillar For Following Size Of Air Valves Including Earthwork Excavation, Rcc M25 Grade For Base Slab, Vertical Pillar, Including Cost Of Steel Reinforcement , Gi ( Class-B ) / Ms Vertical Pipe, Form Work, Proper Curing Of Concrete Work Complete In All Respect As Per Standard Specifications And Drawings And As Directed By Engineer.Air Valve Pillarfor Airvalves Size Of 150Mmdia 78 Construction Of Rcc Sluice Valve Chamber For Different Type Of Valves Including Earthwork Excavation, 100Mm Pcc M15as Leveling Course, Rcc M25 Grade For Base Slab, Side Wall & Cover Slab , Including Cost Of Steel Reinforcement , Form Work, Pre-Cast, Plastic Encapsulated Ci / Ms Foot Rest, Ms Flats For The Support Of Pre-Cast, Proper Curing Of Concrete Work Complete In All Respect As Perspecifications And Standard Drawings And As Directed By Engineer-In-Charge.For Class-Aa Loading 79 Sluice Valve Chamber Of Size 1.13 M X0.85 M X1.325 M-For Pipe Size-Upto 100 Mm 80 Sluice Valve Chamber Of Size 1.17M X 0.95M X1.47Mfor Pipe Size-From 125-To-150Mm 81 Sluice Valve Chamber Of Size 1.26M X1.185M X1.88M For Pipe Size-From 200-To-300Mm 82 Sluice Valve Chamber Of Size 1.39M X1.43M X2.245Mfor Pipe Size-From 350-To-450Mm 83 Sluice Valve Chamber Of Size 1.61M X1.75M X2.85Mfor Pipe Size-From 500-To-700Mm 84 Dismantling Of Cement Concrete Pavement For Pipe Line Line And Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 85 Dismantling Of Flexible Pavement For Pipe Line Line And Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work.Bituminous Courses 86 Dismantling Of Flexible Pavement For Pipe Line Line And Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work.Granular Courses 87 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:3:6 ( 1 Cement : 3Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 88 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work.M20 Grade Nominal Mix 1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 89 Repair Of Bituminous Roadusing Gsb 15 Cm Thick, Wbm 15 Cm Thick In Two Layers , 20 Mm Thick Bitumin Carpet And Sand Seal Coat Complete As Per Specification And Scope Of Work. ( Based On Dausa 2019 Pwd Bsr Road 2019 90 Providing And Laying In Position Specified Grade Ofcement Concrete Forall Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix 91 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 92 60 Mm Thick. 93 80 Mm Thick. 94 100 Mm Thick 95 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 96 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Three Level. Thermo-Mechanically Treated Bars ( Conforming Of Relevent Is Code ) 97 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 98 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 99 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 100 Rates For Rcc Ohsr, Sbc 18 T / Sqm, Seismic Zone-Ii & Staging 20 M 101 200Kl Capacity 102 500Kl Capacity 103 1250Kl Capacity 104 1500 Kl Capacity 105 2600 Kl Capacity 106 Rates For Rcc Ohsr, Sbc 18 T / Sqm, Seismic Zone-Ii & Staging 18 M 107 2900 Kl Capacity 108 Providing And Fixing Double Flanged Isi Marked Diclass K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , Asvertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing And Fixing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testingetc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 109 200 Mm 110 250 Mm 111 300 Mm 112 350 Mm 113 400 Mm 114 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 115 Bfm 150 Mm 116 Bfm200 Mm 117 Bfm 250 Mm 118 Bfm300 Mm 119 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioning Technical Specifications And As Per Direction Of Engineer. Class Pn 1.0 120 80 Mm Dia 121 100 Mm Dia. 122 125 Mm Dia 123 150 Mm Dia. 124 200 Mm Dia. 125 250 Mm Dia. 126 300 Mm Dia. 127 350 Mm Dia. 128 400 Mm Dia. 129 450 Mm Dia. 130 600 Mm Dia. 131 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Stone Masonary In Cm: 1:6 Section Of Foundation Above Pcc, 600 Mm ( W ) X 450 Mm ( D ) And 450 Mm ( W ) X 450 Mm ( D ) 4. Superstructure Work: Stone Masonary In Cm: 1:6, W-300, Height-1650 Mm, / Brick Work In Cm: 1:6 W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 132 For Esr 133 Proposed Pump House 134 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. For Esr 135 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. Proposed Pump House 136 Construction Of Rcc ( Flat Slab Type ) Rectangular Clear Water Reservoir Of Following Capacity As Per The Scope Of Work And Technical Specification, Consisting Of The Following Main Activities: -A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction.B ) Excavation In All Types Of Soil, Pcc Below Foundation & All Rcc Work Including All Labour And Material Charges Including Providing And Fixing Of Accessories Such As Ss Ladder, Ss Manhole Frame And Covers, Water Level Indicator ( Float Type ) , Ss Ventilator With Ss Screen, Float Valve, Puddle Collars, G.I. Pipe Railing Around Walk Way, Top Dome / Slab, Staircase In Side And Out Side. C ) Cwr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Vertical Wall Of Cwr. The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Concrete Over 150Mm Thick Compacted Soil Fill. 137 D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface Of The Roof Slab, And 600 Mm Height Of The Vertical Wall. E ) Successful Hydro Test And Water Tightness Test As Per I.S. Code. F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Roof Slab. G ) Providing And Applying Three Coats Of Cement-Based Paint On The Remaining External Surface Area Of The Structure.H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss 304 Ladder From Roof Slab To Bottom Slab, Inside Container. Providing And Fixing Water Level Indicator ( Float Type ) . I ) Providing And Fixing Ms Ladder From Ground To Top Slab.J ) All Ms Parts To Be Painted With Two Coats Of The Enamelled Paint Over The Primer Coat Of Red Oxide. K ) Providing And Fixing Of 150Mm Wide Water Bar For The Construction Joints In The Container. L ) Providing And Fixing Ci / Di Puddle Collars The Vertical Wall For Connecting Inlet, Outlet, Overflow And Washout Pipes Of The Reservoir. M ) Construction Of Inlet Chamber, And Valve Chambers Including Sluice Gate Of Sluice Valve From Inlet Chamber To Main Cwr N ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 138 Rates For Rcc Partially Underground Type Clear Water Reservoir Sbc10 T / Sqm, Seismic Zone-2, 3 & 4 ( And Proposed Pump House ) 139 Construction Of Pump House Of Required Size Suitable For Installation Of Maximum 4 No. Monoblock Pump Sets As Per Approved Ga Drawing, Scope Of Work And Technical Specification Complete Work In All Respect Including Electrical Works For Lighting And Fans, Rain Water Drainage. The Plinth Area Of Pump House Shall Be Area Of Measurement.Proposed Pump House 140 Providing, Installation, Testing And Commisioning Of Vacuum Feed Gas Chlorinator With All Assessories And Making Connection With Existing Pipeline Required Including Supply & Instalation Of Trunnion Roller Support, Auxillary Container Valve, Fluxible Copper Connector, Manifold Valve, Tonner Manifold Pipes, Chlorine Pressure Gauge, Isolation Valve, Gas Filter, Pressure Reducing Valve, Chlorine Gas Pipe With Fittings, Diffuser, Lifting Beam, Load Indicator, 25 Nb Pp Diaphragm Valve On Injector Inlet & Outlet, 32 Od Upvc Pipe For Chlorine Solution, 25 Nb Gi Pipe For Pump Suction & Delivery, 25 Nb Gm Gate Valve On Pump Suction & Delivery, 25 Nb Gm Y Type Stainer On Pump Suction, 25 Nb Gm Check Valve On Pump Delivery, Pressure Gauge With Isolated Valve On Pump Delivery And Chlorine Booster Pump With Motor Of Required Capacity Complete In All Respect As Per Specification And The Direction Of The Engineer2 Kg / Hr Capacity 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor Operating At Syncronised Speed Of Speed 1500 Rpm As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 Discharge 20 To 30 Lps And Head 51 To 60 M 143 Discharge 20 To 30 Lps And Head 20 To 30 M 144 Discharge 80 To 90 Lps And Head 51 To 60 M 145 Discharge 20 To 30 Lps And Head 31 To 40 M 146 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor Operating At Syncronised Speed Of Speed 1500 Rpm As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq.Discharge 281 To 300 Lps And Head 61 To 70 M 147 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 148 Efm100 Mm 149 Efm 150 Mm 150 Efm 200 Mm 151 Efm 250 Mm 152 Efm 300 Mm 153 Efm 400 Mm 154 Efm 600 Mm 155 Providing, Installation, Testing And Commissioning Of Following Stain Less Steel Aisi 304 Expansion Bellows Of 10 / 16 Bar Rating With Tie Rods As Per Technical Specifications And Layout Drawings Including Jointing Material Like Nuts, Bolts, Rubber Gaskets Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer.400 Mm Dia. 156 Providing, Installation, Testing And Commissioning Of Following Stain Less Steel Aisi 304 Expansion Bellows Of 10 / 16 Bar Rating With Tie Rods As Per Technical Specifications And Layout Drawings Including Jointing Material Like Nuts, Bolts, Rubber Gaskets Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer.500 Mm Dia. 157 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ms Dismantling Joint ( Fabricated Steel ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioning Technical Specifications And As Per Direction Of Engineer. 158 100 Mm Dia. 159 150 Mm Dia. 160 200 Mm Dia. 161 250 Mm Dia. 162 300 Mm Dia. 163 Manufacturing, Supplying , Lowering, Laying And Jointing In Position To Correct Line Spirally Welded Saw / Fabricated Ms Pipe Having Bevelled End Plates / Coils, Confirming To Is 3589-2001 Or Its Latest Revision / Amendments, For Following Thickness And Inside Diameter, Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) , Field Joints, Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Completeas Per Technical Specifications Anddirection Of Engineer-In-Charge; ( Excluding Earthwork, But Including Internal And Outer Coating Both Side Epoxy ) . Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 164 Dia Of Pipe: 300.00 Mm ( I.D ) Thickness Of Pipe 5.0 Mm 165 Dia Of Pipe: 400.00 Mm ( I.D ) Thickness Of Pipe 5.0 Mm 166 Dia Of Pipe: 450.00 Mm ( I.D ) Thickness Of Pipe 5.0 Mm 167 Dia Of Pipe: 500.00 Mm ( I.D ) 168 Thickness Of Pipe 5.0 Mm 169 Thickness Of Pipe 7.0 Mm 170 Dia Of Pipe: 700.00 Mm ( I.D ) Thickness Of Pipe 7.0 Mm 171 Supply Of Erw M.S. Black Casing Pipe Isi Marked ( Is: 4270 / 2001 ) Or Amended Up To Dateoffollowing Sizes 172 150 Mm Dia Nb ( Thickness Of Pipe 5.0 Mm & Mass Of Tube 20.13 Kg / M ) 173 200 Mm Dia Nb ( Thickness Of Pipe 5.4Mm & Mass Of Tube 28.46 Kg / M ) 174 250 Mm Dia Nb ( Thickness Of Pipe 7.1 Mm & Mass Of Tube 46.57 Kg / M ) 175 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Ammended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fastners - Cs / Galvenised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings Valves Including All Mateial, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work.Class Pn 1.6 176 40 Mm 177 50 Mm 178 100 Mm Dia 179 Providing And Fixing Double Flanged Isi Markedgi Pipes Medium Duty ( Class B ) Steel Tube As Per Is:1239 Or Amended Up To Date And Zinc Coating As Per Is 4736 With Gi Fittings Excluding Valves As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Bend, Tee Etc. Providing And Fixing With Ms Clamps Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testingetc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 100 Mm 180 Providing, Installation, Testing And Commissioning Of Submersible Dewatering Pump Set Conforming To Relevant Is Codes And As Per Scope Of Work And Technical Specifications, With Water Proof Winding. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Shaft, Impeller, Pump And Motor Body. Motor Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, With Cable Guard. The Pump Set Shall Be Suitable For Direct Coupling, With Suitable Suction Strainer Etc. Completein All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditionsmentioned In Td.2.2 Kw ( 3.0 Hp ) 181 Supplying & Installing 100 Mm Diameter Sealed Diaphragm Bourdon Type Pressure Gauge Of Range 0 To 10 Kg.Including All Jointing Material As Per Specification With Safety Cover. 182 Electrical Work & Scada Work 183 Proposed Ph Electricity Work 184 Supply Installation Testing& Commissioning Of Star Ratedcopper Wound Distribution Transformer ( All The Distribution Transformer Must Bestarratedaspernotificationof ( Bee ) Ministryofpower, Goverenmentofindia ) Offollowingrating11 / 0.433Kvdelta-Star Connected, Vector Group Dyn 11, Onan Cooled & As Per Bee Star Level- 2 & Bis Approved As Per Is 2026-1977 & Lossesas Defined As Peris1180parti2014.Includingstandardaccessorieslike Conservator, Silicagelbreather, Bucholzrelay, Radiator, Fins, Ht Cablebox99.6 %& As Peris:1554 P-I / Is :7098 P - I ( B ) Conductorshallhaveelectrolyticaluminiumconfirmingtois 8130, Is 3975-1999For Armouring Of Cables , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures ( C ) Oemmusthaveiso9001&14001Certificationsforquality Assuarance&Itsowninhousenabllabsetupforalltesting Facilities Forcables .All Above As Per Pre Approved By Engineer In Charge.Foradditionaltechnicalparametersofproducts / Work, Refer Annexure A Attached With This Bsr .3 Core 120.0 Sq.Mm 195 Providing&Makingheatshrinkabletypeindoor / Outdoor / Straight Through Terminations / Joint Kit As Per Pwd Specification For Electrical Works Suitable For11 Kv / 33 Kv Cable With Required Components, Preprationofcableends.Typetestreportshouldbeasper Is13573:2011 Which Covered All Sequence For Table 2 For Termination Kit And Table 3 For Streightthrough Joint Inclusive Thermal & Dynamic Short Circuit Test, Humidity Test, Soil Fog Test. Crosslinking Shall Be Done Out Side Factory With E- Beam / Peroxide Technology. Extrusion Process Shall Be In House Oem Within Same Vicinity. Oem Test Lab Should Be As Per Iso 9001:2015 & 14001 : 2015 & Reports Submitted To Engineer In Charge Includingtesting Etc. As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technicalparametersofproducts / Work, ReferannexureA Attached With This Bsr . 196 11 Kv End Termination Kit Indoor Type 3 Core 120 / 150 / 185 Sq.Mm 197 11 Kv End Termination Kit Outdoor Type3 Core 120 / 150 / 185 Sq.Mm 198 Sitc Of Floor Mounted Drowout Type Pmcc ( Indoor, Dury, Dust Proff Ip-4Xfrontoperatedwith2mmthicksheetmetal Compartmentalised ) Withallaccessibleparts, Headshrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 199 Incommerfeederfortransformer1000a, 50Ka, Acb3pole, Albus Bars, Digitalmultifunctionmetercompatableto Scada, Metering, ProtectionctS, Idmt3o / C&1E / F, Indicating Lamps, Controlfuse, Wiringetc.Completeinallrespectofthesize Appxo 900 ( D ) X.2400 ( H ) X1000 ( D ) 200 Bus Coupler Feeder, 1000 A Acb , 50Ka, 3 Pole Without Release With Albusbars, ProtectionctS, Idmt3o / C&1E / F, Indicating Lamps, Control Fses And Wiring Etc.Complete In All Respect. ( Size : 900 ( W ) X 2400 ( H ) X 1000 ( D ) 201 Mccb Up To 100Aas Outing CtS, Ampermeter With Ss, Voltmeter Withss, Indicatinglamps, Controlfuse, Wiringetc.Completeinall Respect. Size:600 ( W ) X2400 ( H ) X1000 ( D ) 202 Mccb Up To 100Aas Outing CtS, Ampermeter With Ss, Voltmeter Withss, Indicatinglamps, Controlfuse, Wiringetc.Completeinall Respect. Size:600 ( W ) X2400 ( H ) X1000 ( D ) 203 Mccb Up To 100Aas Outing CtS, Ampermeter With Ss, Voltmeter Withss, Indicatinglamps, Controlfuse, Wiringetc.Completeinall Respect. Size:600 ( W ) X2400 ( H ) X1000 ( D ) 204 Mccb Up To 100Aas Outing CtS, Ampermeter With Ss, Voltmeter Withss, Indicatinglamps, Controlfuse, Wiringetc.Completeinall Respect. Size:600 ( W ) X2400 ( H ) X1000 ( D ) 205 400AmccbincomerwithmeeteringctS, Multifuctionmeter Compatibletoscada, Ampermeterwithss, Voltmeterwith Ss, Indicating Lamps, Control Fuse, Wiring Etc.Complete In All Respect. Size:900 ( W ) X2400 ( H ) X1000 ( D ) 206 Sitcofsoftstarterswithpanelsuppliedbymanufacturer Conforming To Applicable Standards With Logic Inputs & Outputs, Relay Outputs And Analogue Outputs, Plug In I / O Connections, Displayof Electrical Parameters, State Of Load & Operating Time, Rs 485 Serial Link For Connections To Modbus. 355Kw 207 S & F Of Star Delta Starter With Mcb, Main And Aux Contactor, O / L Relay, L / Rselectorswitch, 3Indicatinglamps, Start-Stoppush Button , Control Mcb With Panel With All Accessorieswith Following Rating 18.5Kw 208 433V Apfc Panel In Cubicle Made Of Crca Sheet Steel Of Minimum 2.5 / 2.0 / 1.6 Mm Thickness, Comply With Latest Is / Iec, Totally Enclosed Operational On 3 Phase 415 Voltages, 50Hz, Neutrally Grounded, Ip 4X, The Cubicle Panel Shall Be Vermin Proof And Dust-Tight And Shall Be Of Compartmentalized Type Construction, Nine Tank Pre-Treatment Process Before Powder Coating, Paint Shade – Grey Ral 7032, Gasket Material- Neoprene, Ac / Dc / Ct Wiring – 1.5 / 2.5Sqmm Pvc Insulated Multi Strand Copper Flexible Wire, Heat Shrinkable Colour Coded Pvc Bus Bar Sleeves, Cable Entry Incoming – Bottom And Outgoing – Bottom As Per Requirement. The Switchgears And Control Gears Complete With All Necessary Supporting Framework, Nuts And Bolts, Aluminum Bus Bar. The Indoor Apfc Panel Switchesgear ( Air Circuit Breakers, Mccb, Cts, Etc ) And Control Gear ( Microprocessor Based Apfc 8 / 12 Stage Relays, Apfc Duty Contactors, Auxiliary Contacts, Space Heater And Lighting, Digital A & V Meters With Selector Switch, Phase Indications, Hooter, Plug Socket Etc. ) Shall Be Mounted On The Same Panel Complete As Per Technical Specifications And As Directed By Engineer In Charge. 209 Sitc Of Localpush Buttonstation Fabricated With 16Swg Crca Sheet, Paintedwithpolysterpowdercoatedfinishafterchemical Treatmentwithfolliwngitemsandaccessories:- Ishroudedtypepushbuttonwith2nocontactselementfor Start / Forward-Reverse. Iilockablemushroomheadtypepushbuutonwith2nccontact Element. Iii2.5Sqmmclipontypeterminalsasrequriedwith20%Spares. Iv 1.5 Sqmm Pvc Insulated Felxible Copper Wire With Lugs & Ferrules As Requried. 210 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured / Armouredaluminiumcableof1.1Kvgradeasper Pwd Specification For Electrical Worksin Existing Rcc / Hume / Stoneware / Pvcpipe / Openduct / Cabletrenchwithfillingof Excavated Earth In Trench, On Existing Cable Trays Or On Surface Etc.Including Making Necessary Connection, Testing Etc. As Required Of Size Andas Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Gradealuminium Conductor Of Purity >99.6 %& As Peris:1554 P-I / Is :7098 P – I ( B ) Conductorshallhaveelectrolyticaluminiumconfirmingtois 8130, Is3975-1999Forarmouringofcablesinarmouredcable Items, Is5831forsheath, Is10810 ( Part0to64 ) Fortesting Procedures. ( C ) Oemmusthaveiso9001&14001Certificationsforquality Assuarance&Itsowninhousenabllabsetupforalltesting Facilitiesforcables.Appropriatetypetestcertificate / Oemtest Reportshallbesubmitted.Allaboveasperpreapprovedby Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr.Armoured Cable 211 300 Sqmm, 3.5 Core 212 240 Sqmm, 3 Core 213 25 Sqmm, 3 Core 214 4 Sqmm, 3 Core 215 Providingandlayingxlpe / Pvcinsulated&Pvcsheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor As Per Is 1255 Including Excavation Of 30 Cmx75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Iind Class Bricks Covering 3C X 2.5 Sq.Mm 216 Providingandlayingxlpe / Pvcinsulated&Pvcsheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor As Per Is 1255 Including Excavation Of 30 Cmx75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Iind Class Bricks Covering 4C X 2.5 Sq.Mm 217 Providingandlayingxlpe / Pvcinsulated&Pvcsheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor As Per Is 1255 Including Excavation Of 30 Cmx75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Iind Class Bricks Covering 8C X 2.5 Sq.Mm 218 Supply, Fabricating&Installingfollowingsizesofpowdercoatedladder Type M.S. Cable Trays With Rungs At Span Of 250 Mm Including Horizontalandverticalbends, Reducerstees, Crossmembersand Otheraccessoriesasrequiredanddulysuspendedfromthe Ceiling / Wallwithmssuspendersincludingbolts&Nuts, Fastners, Supports, Paintingsuspendersetc.Asrequired.Allasperpre Approvedbyengineerincharge.Foradditionaltechnical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 450Mm X 50Mm X 2.0Mm 219 Supply, Fabricating&Installingfollowingsizesofpowdercoatedladder Type M.S. Cable Trays With Rungs At Span Of 250 Mm Including Horizontalandverticalbends, Reducerstees, Crossmembersand Otheraccessoriesasrequiredanddulysuspendedfromthe Ceiling / Wallwithmssuspendersincludingbolts&Nuts, Fastners, Supports, Paintingsuspendersetc.Asrequired.Allasperpre Approvedbyengineerincharge.Foradditionaltechnical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 600Mm X 50Mm X 2.0Mm 220 Supply, Fabricating & Installing Following Sizes Of Perforated Hot Dipped Galvanized Iron Cable Tray ( Galvanized Thickness Not Less Then 50 Microns ) With Perforation Not More Then 17.5% In Convenient Section Including Horizontal And Vertical Bends, Reducers Tees, Cross Membersandotheraccessoriesasrequiredanddulysuspended Fromtheceilingwithgisuspendersincludinggibolts&Nuts, Fastners, Supportsetc.Asrequired.Allasperpreapprovedby Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 221 100Mm X 50Mm X 1.6Mm 222 150Mm X 50Mm X 1.6Mm 223 300Mm X 50Mm X 1.6Mm 224 450Mm X 50Mm X 2.0Mm 225 Providing & Fixing Of Electricalinsulating Rubber Matts As Per Pwd Specification For Electrical Works, Isi Marked Confirming To Is: 15652 / 2006With One Sideanti Skid Abberation Marks And Pasting The Mat With Synthetic Rubber Adhesive As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 11 Kv, 2.5 Mm Thick With Proof Voltage 22 Kv / 3 Min. And Break Down Voltage45 Kv Etc
Contract Date: Jul 05, 2023 Contract Value : 78.71 Crore
Government Departments No of Bidders 9
12.
Educational and Research Institute #1343536 AOC
Purchase Of Tools And Equipment Required For Survey Lab And Transportation Engineering Lab Under The Civil Engineering Dep-1.01 Vernier Transit Theodolite ( Babir-Vtto1 ) - Resolving Power 4, Field Of View 2.6 M At 100M, Material Aluminium, Short Focus 1.5M, Stadia Ratio 1100, Length 178 Mm Magnification 25X, Effective Aperture 38Mm, Circle Diameter Hz113mm, V100mm. 1.02 Dumpy Level -Levelling Range -1Km, Longest Focusing Distance 200 / 300 Mtr Objective Aperture 40 Mm Stadia Constant 1:100 Addition Constant 0 Bubble Sensitivity 20” / 2 Mm Nominal Accuracy 2-3 Mm / Km Weight 2.650 Kg. 1.03 Cbr Apparatus ( Is 2720-Part Xvi ) - 50 Kn Capacity. Table Top Type -Mould And Proving Ring With Standard Calibration Chart And All Accessories. 1.04 Marshall Stability Apparatus -50 Kn Capacity. Analogue Type With Proving Ring And Dial Gauge. It Consists Of Three Cylindrical Moulds 10.16 Cm Dia X7.6 Cm High With Base Plate And Extension Collars, A Specimen Extractor, Two Hammers ( 4.5 Kg ) With Standard Calibration Chart. 1.05 Test Sieve ( Is 460 ) 20Mm Dia -Brass Made -One Set- ( 4.75Mm, 2.36Mm, 1.18Mm, 0.600Mm0, 0.425Mm, 0.300Mm, 0.150Mm, 0.075Mm ) . 1.06 Test Sieve ( Is 460 ) 30Mm Dia –G I Made -One Set- ( 75Mm, 50Mm, 40Mm, 37.50Mm, 25Mm0, 20.00Mm, 12.50Mm, 10.00Mm, 4.75Mm ) 1.07 Elongation Index Gauge- ( Length Gauge ) -Brass Type-Is2386. 1.08 Thickness Gauge- Flakiness Index- Brass Type-Is2386. 1.09 Automatic Bitumen Compactor Of Fully Automatic Type. ( The Drive Mechanism Lift The Weight Of 4.5 Kg And Drop Height 457Mm ) . Standards Bs 598-107. 1.1 Standard Tar Viscometer- Is 1206 ( Part 1 ) -Consists Of A Chrome Plated Copper Bath With Cup Of 10Mm Orifice And Sleeve With Lifting Clip And Ball And It Operate On220 Volt Ac Mains. Ring And Ball Apparatus- Is 1205 Consists Of Steel Bracket With Sliding Plate Support, A Central Hole On This Plate For Inserting Thermo Meter. It Consists Of Tampered Ring -2 Nos, 1.11 Ball Centring Guide-2 Nos. Steel Ball Of 9.5Mm Dia & Magnetic Stirrer With Heating Facility. 1.12 Bitumen Ductility Testing Machine- Is 1208 -Testing Range1.5-2M, Rotating Shaft Speed 5 Cm / Min. The Briquette Is Stretched Rate Of 50 Mm / Min. It Consist Of A Water Bath With Thermostatic Heater And Circulating Pump .It Operate On 230 V And Inner Material Is Stainless Steel.
Contract Date: Jun 07, 2022 Contract Value : 3.77 Lakh
Government Departments No of Bidders 12
TenderDetail
Loading tenders