View Bid Results For Amc Of Window Air Condition Tenders

We found 24 Bid Results related to amc of window air condition tenders. You can find Contractor details who won amc of window air condition tenders along with contract details in Bid awards announcements section.

Filters
Stage
16
7
1
Tender Publishing Platform
24
State / UT
9
7
4
3
3
2
2
1
1
1
Contract Value
10
2
8
4
Publish Date
0
0
0
0
0
Sector
8
8
5
4
3
1
1
1
1
Ownership
3
13
7
4
Within keyword
Active filters:
Showing 1–1 of 24 tenders matching your filters
1.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
2.
Housing Urban and Rular Development #10825582 Price Bid
repair maintenance of Electrical And Mechanical Services Of Various Office Building At Probin Road , Lucknow Road , Delhi . ( Sh- Servicing , Overhauling And Amc Of Split-Windows Air Conditioners And Water Cooler ) , comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity . water cooler/ ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc bimonthly as required at site i/c servicing of wtac /stac/cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting/running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condensor fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . /split/cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units/water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conditioning equipments/water coolers within a period of one month and submit the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment have been serviced by contractor . ) the contractor will handover all the unit in fully functinal condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be considence while quoting the rates . ( total nos= 131 , inventory attached ) a ) summer ( 8 months ) , b ) winter ( 4 months )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
3.
Housing Urban and Rular Development #10612230 Price Bid
1 ) repair maintenance of electrical and mechanical services of vrs social welfare bldg . at sewa kutir , kingsway camp 2 )repair maintenance of electrical and mechanical services at juvenile jail , majnu ka tilla 3 ) rmo e and m services at da flats , timarpur , delhi . ( sh - servicing , overhauling and amc of split / window acs and water cooler ) , ( part-a ) comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity water cooler / ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc as required at site i / c servicing of wtac / stac / cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting / running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condenser fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . / split / cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units / water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conitioning equipments / water coolers within a period of one month and submitt the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment have been serviced by contractor . ) the contractor will handover all the unit in fully functional condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be confidence while quoting the rates . a ) summer ( 8 months ) for 208 unit , b ) winter ( 4 months ) for 60 unit , comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity water cooler / ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc as required at site i / c servicing of wtac / stac / cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting / running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condenser fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . / split / cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units / water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conitioning equipments / water coolers within a period of one month and submitt the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment has been serviced by contractor . ) the contractor will handover all the unit in fully functinal condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be confidence while quoting the rates . a ) summer ( 8 months ) for 131 unit , b ) winter ( 4 months ) for 33 unit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
4.
Housing Urban and Rular Development #10542166 Price Bid
1 ) Rmo E And M Services Of Vrs Social Welfare Bldg At Sewa Kutir , Kingsway Camp . 2 ) Rmo E And M Services At Juvenile Jail , Majnu Ka Till , Delhi 3 ) Rmo E And M Services At Da Flats , Timarpur , Delhi . ( Sh- Servicing , Overhauling And Amc Of Split-Windows Acs And Water Cooler ) , Comprehensive Running Maintenance Of Window Type A . C Unit / Split Type A . C Unit / Cassettes Type A . C Units Of 1 . 5 T . R / 2 . 0 T . R Capacity . Water Cooler/ Ductable Ac Coloum Etc . For Twelve Months ( 8 Months Summer+ 4 Months Winter ) After Completion Of Servicing Overhauling Repairing Etc Bimonthly As Required At Site I/C Servicing Of Wtac /Stac/Cassette Type A . C Units Including Cleaning , Washing With High Pressure Water Spray Electric Machine , Coil Cleaning With Chemical , Blower Oiling , Greasing Including Replacement Of Blower , Motor , Compressor , Pcb , Plug Top , 3 Core Copper Conductor Cable , Starting/Running Capacitor Of Suitable Size , Relay Suitable For 1 . 5 , 2 Tr Unit , Condensor Fan , Filter Pvc , Fan Blades , Thermostat , Remote And All Types Of Defective Parts For Proper Functioning Of Equipments , Condenser Coil , Cooling Coil , Charging Of Refrigerant Gas To Make The Already Installed W . T . /Split/Cassette Type A . C Units Fully Functional With Genuine Spares And Reinstallation Of The Same Etc . Complete As Required . The Ac Units/Water Cooler Will Be Handed Over To The Agency On As It Is Where It Is Bases For Servicing And Comprehensive Maintenance . The Firm Is Advised To Visit The Site , Before Quoting The Rates . All The Above Units Were Functional Last Year , Nothing Extra Shall Be Paid For Above Items For Making The Units Fully Functional , Testing And Commissioning Complete As Reqd . ( Note:- The Contractor Is Required To Complete The Servicing & Repairing Of All Air Conditioning Equipments/Water Coolers Within A Period Of One Month And Submitt The Record To The Department . The Comprehensive Maintenance Shall Be Treated As Started Only After Acceptance By The Department That All Equipment Have Been Serviced By Contractor . ) The Contractor Will Handover All The Unit In Fully Functinal Condition On Completion Of The Work . Dismentaled Material Will Be Taken Back By The Contractor For Which Necessary Rebate Shall Be Confidence While Quoting The Rates . ( Total Nos= 208 , Inventory Attached ) A ) Summer ( 8 Months ) , B ) Winter ( 4 Months )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
5.
Drinking Water Supply and Sanitation #10439994 Price Bid
Supply Of Uv-Visible Spectrophotometer, Double Distillation, Hot Air Oven, Weighing Balance, Ph Meter Bench Top, Conductivity Meter Bench Top, Deep Freezer Complete In All Respect. Rs. 16.16 Lakhestimate For The Work: - Ch. To Water Quality Monitoring System- 1 Portable water quality instrument for the measurement of chemical and physical parameters 150 methods inbuilt for measurement of chemical parameters along with pHand Turbidity optical measuring principle : Led Photometer with filter Dimensions approx 236x86x117 nm interference filter 436mm, 517nm 557nm 594nm, 610nm, 690nm accuracy = 2 nm weight0.6kg (Approx) Dimensions: approx 236 x 86 x 117 nm Photometric reproducibility: 0.005 or better: interface Rs. 232 protection : IP 67 Photometric resolution 0.001: Display Backlit: intuitive user Guidance Relative Humidity : yearly mean <75%:30 days/year: other days: 85% warm-up time : none:’ power supply : 4 x 1.5 V, type AA: Test certificate : cETLus, CE, FCCMeasuring time: approx. 2s; operating time with battery operation : 3000 measurements (Approx).Measured parameters: concentration (method dependent, selectable display form,)Absorbance, transmission; operating time with battery operation : approx. 3000 measurements Measuring range absorbance: -2.000 ... +2.000;Transmission: 1 .... 150%User- defined programs: 100; Data Storage 1000 with identification IDspHRane -2.00 ... 16.00; 3 calibration points; operating time with battery operation: approx. 3000 measurementsORP Rang + 1000mV; Data storage : 1000 with identification IDsTemp Range -5.0....+ 100.0 C; Power Supply 4 x 1.5 V type AApH Resolution / Accuracy: 0.01/ +mVTemp Resolution / Accuracy + 0.3 CTurbidity Range 0.01 ... 1100 NTUTurbidity Resolution : 0.01/0.1/10.01 NTU/FNUMeasuring time : 4 seconds.Turbidity Calibration points: Automatic 3 – point calibrationEutech, WTW(Xylem) Hach,Oakton, ELICO,Lovibond,Thermo FisherScietific 2 Double Distillation Make- Borosil all quartz Verticalcomplete in all respect.with 5 Year (AMC)Specifications: All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with DistillationApparatus Power Supply Capacity 2.5 Ltr/hr 3 Weighing Balance Make-Mettler, Toledo complete in all respect. With 5 Year (AMC)Specifications:Analytical Balance Capacity 220 gm Accuracy 00.1 mg with internal calibration Pan Size Ø 90 mm. Standard ValuesRepeatability (5% Max) 0.015 mg Repeatability (Max) 0.08 mg Minimumweight(USP) 30 mg Minimum weight (U=1%, k=2) 3 mg PermissibleValuesRepeatability(5%Max) 0.02 mg Repeatability(Max) 0.1 mg Linearity ± 0.05 mg Stabilization time 2 seconds AdjustmentInternalVerification Yes OIML Class I Display LCD (with backlight) Keypad 14 keys Protection class IP 43 Databases 5USB-A (interchangeable) 2 USB-B 1RS 2322 Wi-Fi 802.11 b/g/nPower supply 12 ÷ 16 V DC Power consumption 3 WWeighing pan dimensions ø 90 mm open-work ø 85mm standard (option) 4 Turbidity Meter Benchtop Make- Eutech, Hach, Lovibond, Thermo Fisher Scientific WITH Standared solution complete in all respect.CRMs(10,100,200,800)with 5 Year (AMC)Specifications:Range: 0-4000 NTU; Certification: CE, FCC, EC, EN, UL STDCommunication: RS 232, USB via adapterCompliance: ISO Data Log: 1000 total logs, includes reading log, verification log and calibration log, Date Time, UserDisplay: LCD graphic, backlit, menu controlledInterface: RS 232, USB via adapter, external printer, barcode scanner, PCLight source: Light-emitting diode (IR LED)/ Tungsten Filament LampMeasurement method: Nephelometric Operating temperature range: 0 - 50 °C Power requirements (Voltage): 100 - 240 VAC with Lab station, Battery Operated 4 x 1.5 V, type AA for approx. 3,000 measurementsResolution: 0.001 NTU; Repeatability ±1% of reading or 0.01 NTU whichever is greater Accuracy: ± 2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU or betterReading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedureRegulatory: Meets ISO 7027, DIN EN 27027Response time: <15 seconds28x60 mm (1.10x2.36 in.), 20 ml sample volumeCalibration Point Automatic 3-point calibrationWeight approx. 0.6 kg (without batteries)Dimension 236 x 86 x 117 mmSource Lamp: LED Stabilization time: Immediately Storage conditions: -20 to 65 °C Units: FNU and NTU Relative Humidity Yearly mean: < 75 %; 30 days/year: 95 %; Other days: 85 %Type of Protection: IP 67 5 Deep Freezer with Temperature ControllerMake- Blue Star,Cellfrost,Voltas With all respect and with 5 Year (AMC)SpecificationsDouble door deep fridge • Capacity-300 ltr • Heavy duty wheel • Enabled temperature controller to check & maintain inside temperature • Shelf Material/Coolpad: Toughened Glass • Aesthetic soft look design. • UV grade plastic material for long-lasting appearance • Door lock for restricted accessibility • Castor wheels for easy mobility • Environment friendly CFC free insulation. 6 Calibrated WeightsMake - Radwag, Mettler Toledo, complete in all respect.with 5 Year (AMC)Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights) 7 HygrometerMake - HTC instruments, Testo, Thermo Electric Technologies complete in all respect.with 5 Year (AMC)Temp Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Measuring Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1% 8 Thermometer simple and with probe Make - LT, HTC instruments, Hicks complete in all respect.with 5 Year (AMC)Digital LCD Thermometer with sensor probe 9 pH meter (with 5 years AMC)Lovibond, EUTECH, WTW, OAKTON, MetrohmpH Range -2.00 to 16.00 pHResolution/Accuracy 0.01 pH/± 0.01 pHORP Range ± 2000 mVResolution/Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond)1.2 ± 0.2(± 199.9 mV) /± 2 mV (beyond)Temp.range 0.0 to 100.00 C (32.0 to 212.00 F)Resolution/Accuracy 0.1 0 C(0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC)ATC Yes (0 to 100 0 C)Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45No.of pH Calibration Points 5pointsBuilt-in Electrode Arm YesMemory 100data setsElectrode Included ECFC7252101B,single junction pH electrode.Temp.Probe IncludedLCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm)Power Requirements Included, 100 /240VAC SMPS Power Adapterwith US/UK/EUR/Japan plug ,9V,6W,CENTRE 10 Conductivity meter /TDS METER(with AMC for 5years)Lovibond, EUTECH, OAKTON, WTW, Hach, MetrohmConductivity Range 0.01 to 200.0 mS/cmResolution/Accuracy 0.01 / 0.1 µS ; 1 / 0.01mS / 0.1 mS±1 % full scaleResistivity Range 2.000 O to 20.0 MOResolution/Accuracy 0.01 / 0.1 O ; 0.001 / 0.1 kO ; 0.01 MO±1 % full scale 11 Hot Air Oven NST,OPTICS TECHNOLOGY, AMBASSADOR• SIZE:-18X18 X18 / 18x24x18• Double walled inside Aluminum/Stainless Steel 304 qty.• Outside made of Mild steel and painted in Epoxy Powder Coating.• Insulation of 75rnm by mineral Wool.• Double walled inside Aluminum/Stainless Steel 304 qty.•good stoving enamel with adjustable wire mesh nichol plated trays• Heating Elements are on three sides bottom LHS & RHS. ribs.• With air ventilators on two sides.• Microprocessed Electronic Digital Controller cum Indicator from few C above ambient to 300 C ±0.5* C having two windows display SV & PV, auto tuning, timer up 999 mts (selectable) low & high temp. accuracy alarm, cycle, timer with buzzer.• Outside made of Mild steel and painted in Epoxy Powder Coating.• Insulation of 75rnm by mineral wool.• Double walled inside Aluminum/Stainless Steel 304 qty.• Heating Elements are on three sides bottom LHS & RHS. ribs.• With air ventilators on two sides.•Steel stand should be provided along with tyres on which instrument has to kept .•Traceabilitycalibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory.Includes AMC for 5 years 12 Autoclave VerticalPOPULAR ,NST, AMBASSDORSize-78 ltr/ 98 ltr• It should have double wall construction with boiler made of Stainless Steel 16 gauge sheet. Outer shall is also made of Stainless Steel Sheet/ Mild Steel. Boiler and outer shell is provided with air insulation. Lid is made of Stainless Steel Sheet and tightened all-round by radial locking . Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested upto 40 PSI.• Should have fully automatic PID Controller• Automatic timer electronic 999 mts • Sterilizers are fitted with water level arrangement to indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fitted with indfoss pizzostat and can be set between 10 to 20 PSI.• Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cut-off automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceabilitycalibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory.• Includes AMC for 5 years 13 DessicatorBorosil, Glassco, Thermo250 mm along with 1 kg silia gel (Qualigen) 14 Bacteriological incubatorNST,AMBASSADOR,OPTICS TECHNOLOGYSize 18x24x18.The incubator should havedouble door outer is metal door and inside is glass door in stainless steel frame. There will be glass window outside .Two adjustableair ventilators are placed near thetop of the sides.The temperature is controlled by an Electronic microprocessed Temperature Controller cum Indicator from few °Cabove ambient to 70 deg. Cwith sensitivity of plus minus 0.5 deg. Csupplied complete with two pilot lamps,aircirculating fan perforated shelves adjustable at any level, havingarrangement to fit the automatic timer to work on 220/230 volts A.C. only with cord and plug.Double walled inside Aluminum/Stainless Steel 304 qty.Steel stand should be provided along with tyres on which instrument has to kept .Good stoving enamel with adjustable wire mesh nichol plated traysTraceabilitycalibration certificate of controller should be provided Instrument should be calibrated from NABL calibration laboratory.Includes AMC for 5 years 15 Laminar Air flow (Horizontal)NST, Ambassador, Optics Technology• Working table of SS-304• HEPA of 0.3 m of an efficiency of 99.7 %• confirm international standard 209 E• statically balanced motor• velocity at the output of HEPA 90+ 20 FPM• Vibration is also very low• work area is properly illuminated by diffused glare free fluorescent light• front & side door of acrylic sheet (transparent)• cock for gases or vacuum line• LCD display with soft touch switches for motor, UV light, UV timer• microprocessor based touch screen display• door sensor to switch off UV light when door is closed• control of UV light to prevent operator from the UV rays as and when required. 16 Sodium chloride(CRM)Source-MerckTraceability -NIST, Size 80 gm, atleast with 2 yr expiry date 17 Calcium Carbonate(CRM) Source-Merck, size- 50 gmTraceability -NIST,atleast with 2 yr expiry date 18 Sodium Carbonate(CRM) Source-Merck, size-80 gmTraceability -NIST,atleast with 2 yr expiry date 19 Nitrate ISA solution 475 ml With certficate-Make-Me6rck/orion,atleast with 2 yr expiry date 20 TISAB-III With certificate,Make-orion/merck-475 ml 21 Fluoride standard-100 ppm,475 ml,CRM with certificate,NIST TRACEABLE-orion/merck-atleast with 2-3 yr expiry date 22 Nitrate Standard 100 ppm 475 ml,(crm)NIST traceabl with certificate -orion/merck-atleast with 2-3 yr expiry date 23 Ph buffer calibration solution-4.01,crm,nist traceable with certificate-orion/merck-475 ml,atleast with2-3 yr expiry date 24 Ph buffer calibration solution-7.0,crm,nist traceable with certificate-orion/merck-475 ml,atleast with2-3 yr expiry date 25 Ph buffer calibration solution-10.01,crm,nist traceable with certificate-orion/merck-475 ml,atleast with2-3 yr expiry date 26 Mac Conkey brooth-Himedia-500 gm.atleast with2-3 yr expiry date 27 Sulfaver-Hach-1 packet (100 pouch) atleast 2-3 yr expiry date 28 Ferrover-Hach-1 packet (100 pouch) atleast 2-3 yr expiry date 29 Spadns reagent for fluoride-Hach (500 ml)-1 packet (100 pouch) atleast 2-3 yr expiry date 30 Nitraver-Hach-1 packet (100 pouch) atleast 2-3 yr expiry date 31 Silver nitrate -AR Grade-25 gm,Make-Himedia/Sigma aldrich/Merck- with atleast 2-3 yr expiry date 32 EDTA (AR Grade) 500 gm-Make SD Fine/Merck/Finar/QUALIGEN with atleast 2-3 yr expiry date 33 Potassium Chromate-AR Grade -500 gm-Make SD fine/Finar/Qualigen with atleast 2-3 yr expiry date 34 Sodium Hydroxide -AR Grade -500 gm,Make Sdfine/Finar/Qualigen with atleast 2-3 yr expiry date 35 Conc.HNO3 -500 ml,Make-Fischer Scientific with atleast 2-3 yt expiry date 36 Eriochrome Black-T-AR Grade-25 gm,Make-Qualigen with atleast 2-3 yr expiry date 37 Methyl Orange-125 ml-Make-Qualigen/Sdfine with atleast 2-3 yr expiry date 38 Murexide Indicator-5gm,Make Sdfine/Qualigen 39 Sulphuric Acid (0.02 N)-500 ML-Make-Qualigen/Fischer Scientific with atleast 2-3 yr expiry date 40 Ammonium Buffer solution (500ml ) 41 Iso Propyl Alcohal (3L) 42 Acetic acid Glacial (500ml) 43 Sodium Acetate trihydrate (500g) 44 Magnesium Chloride hexahydrate (500g) 45 M-Endo AGAR (500g) 46 Potassium Chloride (500g) 47 Bromocresol green indicatior with Sodium metal (5g) 48 Hydroxylamine hydrochloride (500g) 49 Ammonium hydroxide (500ml) 50 Ammonium acetate buffer (250g) 51 Phenanthroline monohydrate (25g) 52 Potassium permegnate (25g) 53 Stock iron solution (100ppm) 54 Stock Sulfate Standard Solution (1000ppm) 55 Volumetric Flask 50ml Borosil A Grade with NABL Certificate 56 Volumetric Flask 100 ml Borosil A Grade with NABL Certificate 57 Volumetric Flask 250 ml Borosil A Grade with NABL Certificate 58 Volumetric Flask 500ml Borosil A Grade with NABL Certificate 59 Volumetric Flask 1000ml Borosil A Grade with NABL Certificate 60 Measuring Cylinder 50ml Borosil A Grade with NABL Certificate 61 Measuring Cylinder 100 ml Borosil A Grade with NABL Certificate 62 Measuring Cylinder 250ml Borosil A Grade with NABL Certificate 63 Pipette 2 ml (Graduated) Borosil A Grade with NABL CertificateGraduation interval 0.02ml 64 Pipette 5 ml (Graduated) Borosil A Grade with NABL CertificateGraduation interval 0.05ml 65 Pipette 10 ml (Graduated) Borosil A Grade with NABL CertificateGraduation interval 0.05ml 66 Pipette 10 ml (Single Mark) Borosil A Grade with NABL Certificate 67 Pipette 20 ml (Single Mark) Borosil A Grade with NABL Certificate 68 Beaker –Borosil -100 ml 69 Beaker-Borosil-250ml 70 Beaker-Borosil-500 ml 71 Beaker-1000 ml 72 Tongs 8” 73 Durams Tubes( 1 Pack or Grovs) (Borosilicate Glass) 74 BuretteStandswith Clamp (Poly Lab) 75 Funnel 100mm(Borosil) 76 Lab Coat-Good Quality 77 Hand Sanitizer-(with Ethyl Alcohol)Dettol/Cipla/Savlon/ Certified ISI Marked Reputed Brand- 5ltr 78 Draining Basket-Polylab 79 Test tube peg rack 80 Labolene-Glassware cleansing Solution, 5ltr,Make-Qualigen 81 Autoclavable HIcap-Size18 mm,Make-Himedia (100 cap per box) 82 Autoclavable HIcap-Size15 mm,Make-Himedia (100 cap per box) 83 Whatman Filter Paper-Size 125mm 84 China Dish (Flat Surface) ( 100ml capacity and approx 90mm dia) 85 Spatula big spoon 7.5 86 Basket for test tube 87 Funnel
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
6.
Public Administrative Department #10379186 Price Bid
Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System And Integrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And M , Supply, Installation, Testing, Commissioning And Maintenance For Cctv Camera Surveillance System Andintegrated Command Control ( Iccc ) Surveillance System For Palghar Muncipal Conucil Area 58 Cameras And 3 Year Amc ( Semi-Comprehensive Service And Maintenance Contract 3 Years ) . Palghar. , Supply, Installation, Testing & Commisioning Of 5Mp Bullet Camera Image Sensor 1 / 2.9 Progressive Scan Cmos Min. Illumination Color: 0.01 Lux @ ( F1.2, Agc On ) , 0.028 Lux @ ( F2.0, Agc On ) , 0 Lux With Ir Shutter Speed 1 / 3 S To 1 / 100, 000 S Slow Shutter Yes Day & Night Ir Cut Filter Digital Noise Reduction 3D Dnr Wdr 120Db 3-Axis Adjustment Pan: 0° To 360°, Tilt: 0° To 100°, Rotate: 0° To 360° Focal Length 2.8 / 4 / 6 / 8 Mm Aperture F2.0 Focus Fixed Fov 2.8 Mm, Horizontal Fov: 97°, Vertical Fov: 63°, Diagonal Fov: 120° 4 Mm, Horizontal Fov: 78°, Vertical Fov: 50°, Diagonal Fov: 97° 6 Mm, Horizontal Fov: 60°, Vertical Fov: 39°, Diag Onal Fov: 75° 8 Mm, Horizo Ntal Fov: 39.5°, Vertical Fov: 26°, Diagon Al Fov: 48° Lens Mount M12 Ir Range Min 50 M Wavelength 850Nm Video Compression Main Stream: H.265 / H.264 Sub-Stream: H.265 / H. 264 / Mjpeg Third Stream: H.265 / H.264 H.264 Type Main Profile / High Profile H.264+ Main Stream Supports H.265 Type Main Profile H.265+ Main Stream Supports Video Bit Rate 32 Kbps To 16 Mbps. Smart Event Line Crossing Detection, Intrusion Detection, Face Detection Basic Event Motion Detection, Video Tampering Alarm, Exception ( Network Disconnected, Ip Address Conflict, Illegal Login, Hdd Full, Hdd Error ) Linkage Method Trigger Recording: Memory Card, Network Storage, Pre-Record And Post-Record Trigger Captured Pictures Uploading: Ftp, Http, Nas, Email Trigger Notification: Http, Isapi, Email Region Of Interest Support 1 Fixed Region For Main Stream And Sub-Stream Max. Resolution, 25 Fps In All Resolution 30Fps ( 2560 × 1440, 1920 × 1080, 1280 ×720 ) Sub-Stream 50Hz: 25Fps ( 640 × 480, 640 × 360, 320 × 240 ) 60Hz: 30Fps ( 640 × 480, 640 × 360, 320 × 240 ) Third Stream 50Hz: 25Fps ( 1280 × 720, 640 × 360, 352 × 288 ) 60Hz: 30Fps ( 1280 × 720, 640 × 360, 352 × 240 ) Image Enhancement Blc / 3D Dnr / Hlc Image Setting Rotate Mode, Saturation, Brightness, Contrast, Sharpness, Agc, And White Balance Are Adjustable Byclient Software Or Web Browser Target Cropping No Day / Night Switch Day / Night / Auto / Schedule Network Storage Support Micro Sd / Sdhc / Sdxc Card ( 128G ) , Local Storage And Nas ( Nfs, Smb / Cifs ) , Anr Protocols Tcp / Ip, Udp, Icmp, Http, Https, Ftp, Dhcp, Dns, Ddns, Rtp, Rtsp, Rtcp, Pppoe, Ntp, Upnp, Smtp, Snmp, Igmp, 802.1X, Qos, Ipv6, Udp, Ssl / Tls General Function Anti-Flicker, Three Streams, Heartbeat, Mirror, Privacy Masks, Password Reset Via E-Mail, Pixel Counter, Http Listening Security Password Protection, Complicated Password, Https Encryption, 802.1X Authentication ( Eap-Tls 1.2, Eap-Leap, Eap-Md5 ) , Watermark, Ip Address Filter, Basic And Digest Authentication For Http / Https, Wsse And Digest Authentication For Onvif, Tls1.2Api Onvif ( Profile S, Profile G, Profile T ) , Isapi, Sdk Simultaneous Live View Up To 6 Channels User / Host Up To 32 Users 3 Levels: Video Output No Communication Interface 1 Rj45 10M / 100M Self-Adaptive Ethernet Port On-Board Storage Built-In Microsd / Sdhc / Sdxc Slot, Up To 128 Gb Svc H.264 And H.265 Encoding Support Reset Button Yes Operating Conditions -30 °C To +60 °C ( -22 °F To +140 °F ) , Humidity 95% Or Less ( Non-Condensing ) Power Supply 12 Vdc ± 25%, F 5.5Mm Coaxial Power Plug Poe ( 802.3Af, Class 3 ) Power Consumption And Current :12 Vdc, 0.6 A, Max. 7 W Poe: ( 802.3Af, 36 V To 57 V ) , 0.3 A To 0.2 A, Max. 8.5 W Max. 12 W Protection Level Ip67. Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning.Of 5Mp Bullet Camera. Image Sensor-1 / 2.7 Cmos, Max. Resolution-2592 ( H ) × 1944 ( V ) , Rom-128 Mb, Ram-512 Mb, Scanning System Progressive Electronic Shutter Speed Auto / Manual 1 / 3 S–1 / 100, 000 S Min. Illumination 0.005 [email protected] ( Color, 30 Ire ) 0.0005 [email protected] ( B / W, 30 Ire ) 0 Lux ( Illuminator On ) S / N Ratio>56 Db Illumination Distance-60 M ( 196.85 Ft ) ( Ir Led ) Illuminator On / Off Control Auto;Manual Illuminator Number 4 ( Ir Led ) , Pan / Tilt / Rotation Range Pan: 0°–360° Tilt: 0°–75° Rotation: 0°–360° Lens Type Motorized Vari-Focal Lens Mount F14 Focal Length-2.7 Mm–13.5 Mm, Max. Aperture-F1.5 Field Of View H: 100°–30° V: 72° –23° D: 134° –38° Iris Control-Fixed Close Focus Dista Nce-0.8 M ( 2.62 Ft ) Dori Distance Lens Detect Observe Recognize Identify W 64.4 M ( 211.29 Ft ) 25.8 M ( 84.65 Ft ) 12.9 M ( 42.32 Ft ) 6.4 M ( 21.00 Ft ) T221.4 M ( 726.37 Ft ) 88.6 M ( 290.68 Ft ) 44.3 M ( 145.34 Ft ) 22.1 M ( 72.51 Ft ) Ivs ( Perimeter Protection ) Tripwire; Intrusion ( The Two Functions Support The Classification And Accurate Detection Of Vehicle And Human ) Smart Search-Work Together With Smart Nvr To Perform Refine Intelligent Search, Event Extraction And Merging To Event Videos.Video Compression 25 Fps In All Resolution Bit Rate Control Cbr / Vbr Video Bit Rate H.264: 3 Kbps–8192 Kbps H.265: 3Kbps–8192 Kbps Day / Night Auto ( Icr ) / Color / B / W Blc Yes Hlc Yes Wdr 120 Db Scene Self-Adaptation ( Ssa ) Yes White Balance Auto; Natural; Street L Outdoor; Manual; Regional Custom Gain Control Auto;Manual Noise Reduction 3D Dnr Motion Detection Off / On ( 4 Areas, Rectangular ) Region Of Interest ( Roi ) Yes ( 4 Areas ) Smart Illumination Yes Image Rotation 0° / 90° / 180° / 270° ( Support 90° / 270° With 1080P Resolution And Lower ) Mirror Yes Privacy Masking 4 Areas. Audio Compression G.711A; G.711Mu; Pcm; G.726 ( Only - Zas Supports ) . Alarm Event -Zas:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Audio Detection; Voltage Detection; Defocus Detection; External Alarm; Smd; Safety Exception-Zs:No Sd Card; Sd Card Full; Sd Card Error; Network Disconnection; Ip Conflict; Illegal Access; Motion Detection; Video Tampering; Intrusion; Tripwire; Scene Changing; Voltage Detection; Defocus Detection; Smd; Safety Exception. Network Port Rj-45 ( 10 / 100 Base-T ) Sdk And Api Yes Cyber Security Video Encryption; Firmware Encryption; Configuration Encry Ption; Digest; Wsse; Account Lockout; Security Logs; Ip / Mac Filtering; Generation And Importing Of X.509 Certific Ation; Syslog; Https; 802.1X; Trusted Boot; Trusted Exec Ution; Trusted Upgrade Network Protocol Ipv4; Ipv6; Http; Tcp; Udp; Arp; Rtp; Rtsp; Rtcp; Rtmp; Smtp; Ftp; Sftp; Dhcp; Dns; Ddns; Qos; Upnp; Ntp; Multicast; Icmp; Igmp; Nfs; Samba; Pppoe; Snmp Interoperability Onvif ( Profile S / Profile G / Profile T ) ; Cgi; P2p; Milestone; Genetec User / Host 20 ( Total Bandwidth: 64 M ) Storage Ftp; Sftp; Micro Sd Card ( Support Max. 256 Gb ) ; Nas Browser Ie Chrome, Firefox Management Software Smart Pss; Dss; Dmss Mobile Client-Ios; Android.Audio Input 1 Channel ( Rca Port ) ( Only - Zas Supports ) Audio Output 1 Channel ( Rca Port ) ( Only - Zas Supports ) Alarm Input 1 Channel In: 5 Ma 3–5 Vdc ( Only - Zas Supports ) Alarm Output 1 Channel Out: 300 Ma 12 Vdc ( Only - Zas Supports ) Power Supply 12 Vdc / Poe ( 802.3Af ) Power Consumption Basic: 3.3 W ( 12 Vdc ) ; 4.2 W ( Poe ) Max ( Wdr + Ir Intensity + Intelligence On ) : 7.8 W ( 12 Vdc ) ; 9.7 W ( Poe ) Environment Operating Temperature –30 °C To +60 °C ( –22 °F To +140 °F ) Operating Humidity =95% Storage Temperature–40 °C To +60 °C ( –40 °F To +140 °F ) Protection Ip67.Warranty Of 1 Year. , Supply & Installation Of Camera Housing For Outdoor Suitable For High Temperature Environment, Working Temperature- 20? ~ +60?, Humidity 95% Or Less ( Non-Condensing ) , Main: Aluminum Alloy Window: Glass, Dimension ( Mm ) -455.3×169.2×110, Protection Level-Ip67. , Supply & Installation Of Camera Bracket Mount With Bracket Type: Pan Tilt Brackets, Dimensions Mm: 190 X 200 X 500 Mm, Max Load Kg-50, Housing Material-Steel. , Supply, Installation, Testing & Commisioning. 4 X 100M Poe Ports, 1 X 1000M Rj45 Port, And 1 X 1000M Sfp Fiber Optical Port. Supports Ieee 802.3At / Af. Supports Ieee 802.3, Ieee 802.3U And Ieee 802.3X.Supports High Priority Ports. Supports 8-Core Power Supply. Up To 250 M Transmission Distance. Poe Port With 6 Kv Surge Protection.Supports Poe Output Power Management. 1000M Network Access.Wire-Speed Forwarding And Non-Blocking Design.Store-And-Forward Switching.Solid High-Strength Metal Shell.Power Supply Specification 100~240 Vac, 50 / 60 Hz, Max. 2.5 A. Warranty Of 1 Year. , Supplying And Laying Of Cat-6 Cable With Rodent Proof And Anti Termite Jacket Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supplying And Laying Of Cat-6 Armoured Cable With Eccs Tape Suitable For Networking As Per Specification No. Wg-Coc / Nc , Supply, Installation, Testing & Commisioning. 128G 128Gb Microsd Cards For Surveillance 128 Gb Maximum Read Speed: 96 Mb / S Maximum Read Speed: 96 Mb / S Compatible With Microsdhc, Microsdxc, Microsdhc Uhs-I, And Microsdxc Uhs-I Host Devices. Warranty Of 1 Year. , Supply, Installation & Testing Of 6 U Outdoor Rack Item Type Technical Parameter Layout & Mounting One Compartment, Pole & Wall Mountable Equipment Installation Method 19” Standard Rack Door With One Front Door With Lock ( Support Padlock ) Material 1.Galvanized Steel;2.Single Wall, Thickness Of : 1.2Mm, Thickness Of Mounting Angles:1.5Mm Structure Assembled, Welded Constructions, Ingress Protection Ip65 Temperature Control Cooling Ac220v 90 Cfm Dual Fan.Lighting Led Lamp Ac230 V Or Dc 48V Led Lamp- Optional Temperature Temperature Working Temperature: -40°C ~ +55°C Storage Temperature: -50°C ~ + 70°C Transport Temperature: -50°C ~ +70°C Humidity Relative Humidity 5% ~ 100% Pressure Air Pressure 62Kpa ~ 101Kpa ( Similar To 0M ~ 5000M Altitude ) Radiation Intensity Solar Radiation Intensity 1124 × ( 1±5% ) W / M2 ) Warranty For 1 Year. , Supply, Installation, Testing & Commisioning. Media Converter, Auto-Negotiation Of Half-Duplex / Full-Duplex Transfer Mode Extends Fiber Distance Up To 15Km.1× 1000M Sc / Upc Port 1× 10 / 100 / 1000M Rj45 Port ( Auto Mdi / Mdix ) . Single-Mode Fiber, Utp Category 5, 5E Cable ( Maximum 100M ) Eia / Tia-568 100O Stp ( Maximum 100M ) .Operating Temperature: 0?~50? ( 32?~122? ) . Warranty Of 1 Year. , Supplying And Erecting Lszh Armoured Multimode Optical Fibre Cable With 12 Fibres, Core Dia 50 / 125 ?M ( Om3 ) , Suitable Up To 10 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench As Per Specification No. Wg-Coc / Ofc , Providing & Erecting 5 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification No. Oh-Pl / Opl. , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T / Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 3 To 5M Octagonal / Conical Gi Pole ) . , Supply, Lnstallation, Testing & Commissioning Of Nvr Viewer Workstation ( Hp / Dell / Lenovo ) With Duel Monitor Support , With Nvr Viewer Software And License Operating System 12Th Gen Lntel Corerm I5- Processor Windows 10 Pro ( Windows 1 1 Pro License Included ) , English8 Gb, Ddr5, 256 Gb, M.22230, Pcle Nvme, Ssd, Class 35 Power Button; Hard Disk Drive Activity Light ;. Line Ln / Out 4. Universal Audio Jack S.Usb 3.2 Gen 2Type A With Power Share 6. Usb 3.2 Gen2x2 Type C ( 20Gb Data ) Back ( 35W ) : Knock-Out Slot For External Wireless Antenna ( Optional ) ; Optional Video Port ( Hdmi 2.0B1 Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Type A Ports ( 2 - One With Power On ) ; Padlock Ring And Kensington Security Cable Slot ; Ethernet Rj-45 12. Usb 3.2 Gen 2 Type A Ports ( 2 ) ; Display Ports 1.A ( 1 ; Power Adapter Portback ( 65W ) : ; Knock-Out Slot For Wireless Antenna ; Optional Video Port ( Hdmi 2.0Bl Displayport 1.4A1 Vga / Usb Type-C With Displayport Alt Mode ) ; Usb 3.2 Gen 1 Type A With Smart Power On; Padlock Ring And Kensington Security-Cable Slot ; Ethernet Rj-45; Usb 3.2 Gen 2 Type A Ports ( Z ) ; Displayport 1.4 Ports ( 3 ) ; Power Adapter Port.Warranty Of 1 Year. , Supplying, Erecting, Testing And Commissioning Of 3Kva Capacity Online Pure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups. Warranty Of 1 Year. , Supplying And Erecting 12 V / 65Ah Smf Battery With Battery Terminal Wire, Duly Charged Complete With 24 Months Warranty Complete. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Router - Cable Or Dsl Modem With Ethernet Port, 4 10 / 100 Lan Ports, 1 10 / 100 Wan Port, 2.4 Ghz To 2.497 Ghz, Wep 64 / 128-Bit Data Encryption, Wi-Fi Protected Access ( Wpa / Wpa2 ) , Wps, Network Address Translation ( Nat ) , Stateful Packet Inspection ( Spi ) , Mac Address Filtering, Url Filtering, Power, Internet Status, Wlan , Lan.Warranty Of 1 Year. , Supply, Installation, Testing & Commisioning. Uhd 4K Led Display 86 Interactive Panel With Resolution Of 3840 × 2160 ? Anti-Glare And Anti-Blocking Design To Ensure Smooth Interaction? Dual Systems Of Windows And Android Saving Cost And Easy To Use? Quick Response, At Most 20-Point Touch Control And Smooth Writing Experience? Dual Usb 3.0 Interfaces, And Data From Any Interface Can Be Read In Windows And Android System At The Same Time? Enable The Floating Ball By Gesture To Realize Writing, Erasing, Screenshoting And Freezing In Any Channel? Mirroring By Mobile Phone Or Tablet To Realize Remote Control And Flexible Teaching? Teaching Software Integrating Kinds Of Tools And Materials, Convenient Writing, Erasing, Recording, Preparing And Teaching ? Scan The Qr Code To Save The Teaching Notes ? All-In-One Design With Tempered Glass And Intelligent Temperature Control, Making It Environmental-Friendly And Safety-Guaranteed.Warranty Of 1 Year. , Supply Installation & Testing Ofvms, An Integrated Security Software, Is Designed To Meet Versatile Security Challenges In One Intuitive Platform: From Managing Individual Systems Such As Video Security, Access Control, Intrusion Alarm, Etc., To Collaborating Multiple Systems Under A Unified Architecture. While Protecting People And Property, It Makes Daily Operations More Efficient, And Helps Various Kinds Of Users Make Smarter Decisions. , Supply, Installation And Testing Of 10 Tb Surveillance Storage Hard Disk Drive -24R Surveillance Hdo Capacity - 8 Tb Interface Sata Iii 6 Gb / S Max Sustained Transfer Rate Od-210 Mbs Cache - 256 Mb Tamish Resistant Load / Unloadcycles-300 000 Power On Hours / Year 8760 Mean Tim Between Failures ( Mtbf ) - 1 Million Hours Operating Temperature - Ambient : 41 F / 5 C ( Min ) Drive Case : 158 F / 70 C ( Max ) Non Operating Temperature Ambient : 40 F / 10C ( Min ) . Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 21 U Rack Rack Standard : Conforms To Din 41494 Or Equivalent Standardconstruction : Welded Or Ckd ( Knockdown ) Front Door : Lockable Double Toughened Glass Door Or Perforated Basic Frame : Steel Equipment Mounting : Din Standard 10Mm Sq. Slots / Direct M6 Tapmounting Angle : 19” Mounting Angles Made Of Formed Steelstandard Finish : Powder Coatedtop And Bottom Cover : Welded To Frame, Vented And Cable Entry / Exit Cut Outs From Top & Bottom Standard Mounting Option : Castor Wheels ( Front 2 Wheels With Break And Rear Without Break ) Or Levelers Standard Color : Grey Or Black Static Load : 500Kgs. Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of 8 Port Poe Later 2 Indoor Network Switches With 2 Sfp Port And Modules Complete As Required. 3 Years Defect Liability Period, All Necessary Maintenance, Transportation, Rack And Taxes.Warranty Of 1 Year. , Supply, Installation Testing And Commissioning Of Nvr For Video And Audio Ip Video Input 64-Ch Up To 12 Mp Resolution*: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Incoming Bandwidth 320 Mbps Outgoing Bandwidth 256 Mbps Incoming Bandwidth ( Raid Mode ) 200 Mbps Outgoing Bandwidth ( Raid Mode ) 200 Mbps Hdmi 1 Output 4K ( 3840 × 2160 ) / 60Hz, 4K ( 3840 × 2160 ) / 30Hz, 1920 × 1080 / 60Hz, 1600 × 1200 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Hdmi 2 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hzvga 1 Output 1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Vga 2 Output1920 × 1080 / 60Hz, 1280 × 1024 / 60Hz, 1280 × 720 / 60Hz, 1024 × 768 / 60Hz Video Output Mode Hdmi 1 And Vga 1 Provide Simultaneous Video Output, And Work As The Main Output;Hdmi 2 And Vga 2 Provide Simulta Neous Video Output, And Work As The Auxiliary Output Cvbs Output 1-Ch, Bnc ( 1.0 Vp-P, 75 O ) , Resolution: Pal: 704 × 576, Ntsc: 704 × 480 Audio Output2-Ch, Rca ( Linear, 1 K? ) Two-Way Audio1-Ch, Rca ( 2.0 Vp-P, 1 K?, Using The Audio Input ) Decoding Decoding Format H.265+ / H.265 / H.264+ / H.264 / Mpeg4 Recording Resolution 32 Mp / 24 Mp / 12 Mp / 8 Mp / 6 Mp / 5 Mp / 4 Mp / 3 P / 1080P / Uxga / 720P / Vga / 4Cif / Dcif / 2Cif / Cif / Qcif *: 32 Mp And 24 Mp Is Only Available For Channel 1 When Ultra Hd Resolution Mode Is Enabled. Synchronous Playback 16-Ch Decoding Capability 1-Ch@32 Mp ( 30 Fps ) / 2-Ch@12 Mp ( 20Fps ) / 4-Ch@8 Mp ( 25Fps ) / 8-Ch@4 Mp ( 30Fps ) / 16-Ch@1080P ( 30Fps ) Dual-Stream Recording Support Stream Type Video, Video & Audio Audio Compression. 711Ulaw / G.711Alaw / G.722 / G. 726 / Aac / Mp2l2 / Pcm Network Remote Connection 128 Network Protocoltcp / Ip, Dhcp, Ipv4, Ipv6, Dns, Ddns, Ntp, Rtsp, Sadp, Smtp, Snmp, Nfs, Iscsi, Isup, Upnp™, Http, Https Network Interface 2, Rj-45 10 / 100 / 1000 Mbps Self-Adaptive Ethernet Interface Raid Raid Type Raid0, Raid1, Raid5, Raid6, And Raid10 ( At Least 4 Tb For Each Hdd ) Auxiliary Interface Serial Interface 1 Rs-485 ( Full-Duplex ) , 1 Rs-232, 1 Keyboard, 10 Sata Interfaces Supporting Hot-Plug Esata 1 Esata Interface Capacity-Up To 10Tb Capacity For Each Disk. Alarm In / Out-16 / 4. Usb Interface Front Panel: 2 × Usb 2.0; Rear Panel: 1 × Usb 3.0 Power Supply-100 To 240 Vac, 50 To 60 Hz Consumption-30 W Working Temperature-10 °C To 55 °C ( 14 °F To 131 °F ) Working Humidity 10% To 90% Chassis 3U Weight-10 Kg ( 22 Lb ) .Warranty Of 1 Year. , Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No.Wg-Nas / Utpc. , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 2Nd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 3Rd Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency.From Agency Twice Inspection Will Be Done In A Month And Camera Positionand Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Amc ( Semi-Comprehensive ) Forcamera Complete Solution From On Field Equipments To Command Control Setup For 4Th Year Where Upto Rs.1000 Will Be Waived Off Or Bare By Agency. From Agency Twice Inspection Will Be Done In A Month And Camera Position And Working Status Of Camera Will Be Updated. ( Parts Includes In Semi Comprehensive Amc Are Camera, Poe Switch, Tv, Work Station, Memory Card, Nvr, Inverter & Batteries ) . , Add 4% Contigency Rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
7.
Educational and Research Institute #10365642 Price Bid
Tender For Comprehensive Annual Operation And Maintenance Works & Services At Central University Of Rajasthan.; 1 Comprehensive Annual Operation and Maintenance Works & Services 2 SH-I (a) Deployment of Maintenance Gang for day to day Civil Maintenance work at CURAJ 3 SH-I (b) Operation And Maintenance Of 750 KLD Sewerage Treatment Plant at CURAJ 4 SH-II (a) Electrical & Mechanical Preventive And Day To Day Maintenance Works, Annual Operation, Repair, Maintenance And Periodic Servicing Works Of Pump Houses And Annual Electrical Works At CURAJ 5 Annual preventive and day to day maintenance, to upkeep all the electrical internal & external installations, fittings, fixtures, wiring, Lights, Fans, Geysers etc. functional in the CURAJ campus, for all days in a month, including Sundays and Holidays, including manpower, labour, machinery, general maintenance items, tools & tackles for all deputed staff, safety tools for LT & HT power supply, various type of ladders/tipaya/chopaya etc. as required on site, complete in all respects, as per standard practice. Indicative items are as under: • Wiring/Cabling.• Metal/PVC boxes.• Switches, sockets and accessories of different ratings.• 01phase/03 phase power points & circuits.• 01/03 phase Energy Meters.• Light points/ Fan pts/ Exhaust Fan pts/Call bell pts. etc.• All type of indoor and outdoor lights (conventional/LED/HPSV/MVSV etc.) fittings.• All type of fans (Ceiling/Exhaust/pedestal/wall).• HVLS fans.• Water heaters.• Auditorium stage lights.• Air curtains and electric fly catchers.• Rising mains bus trunking and overhead bus bar of different ratings.• Sandwich rising mains with aluminium bus bar of different ratings.• Switch, disconnector, SFU and MCCB of different ratings.• MCBs, Isolators, RCCBs and MCB DBs of different ratings.• Cable and Boxes of different sizes.• Brass compression glands of different sizes.• Aluminium lugs of different sizes.• HT/LT Cable fault detections and jointing kits.• Overhead electric line.• Road lights.• Lightning arrester and earthing system.• All Electrical indoor and outdoor panels and panel rooms of all buildings.• Maintenance of records etc. and as per tender document. 6 Comprehensive Annual Electrical Operation, Repair, Maintenance and Periodic Servicing Works of pump houses and other water & booster pumps/motors/starters along with associated panels and accessories for all days in a month including Sundays and Holidays, including manpower, machinery, spare parts, consumables, tools & tackles for all deputed staff, safety tools for LT power supply, ladders, ropes etc. as required on site, complete in all respects.Note: Tentative quantity of motors & pumps of different ratings is 30. 7 Providing of uniform to all the deputed staff with reference to (a & b) above, as prescribed by the University and as per tender document. 8 CPWD DSR (E&M) 2022/Chapter-01: Wiring.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 5,00,000/- 9 CPWD DSR (E&M) 2022/Chapter-02: MCCB, MCB, DBs.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 10 CPWD DSR (E&M) 2022/Chapter-05: EarthingThe bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 11 Detection of fault in underground electric Low Tension (LT)/High Tension (HT) cable incl. fault detection machine charges, digging & labour charges etc. complete in all respects as per standard practice. 12 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor LT cable of 1.1 KV grade as required. 13 3½ X 25 sq. mm 14 3½ X 35 sq. mm 15 3½ X 50 sq. mm 16 3½ X 70 sq. mm 17 3½ X 95 sq. mm 18 3½ X 120 sq. mm 19 3½ X 150 sq. mm 20 3½ X 185 sq. mm 21 3½ X 240 sq. mm 22 3½ X 300 sq. mm 23 3½ X 400 sq. mm 24 4 X 16 sq. mm 25 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor HT cable of 11 KV grade as required : 26 70 sq. mm 27 120 sq. mm 28 185 sq. mm 29 240 sq. mm 30 300 sq. mm 31 400 sq. mm 32 General inspection & patrolling of about 10 km long overhead HT/LT lines feeder wise for identification of maintenance work to be carried out i/c strengthing of cross arms with clamps including tightening of nut bolts, removal of birds nest and foreign material from line along with tree/bush trimming under these lines. (to be carried out before starting of summer season and as per the requirement). 33 Annual Servicing of Fans (Ceiling/Exhaust/Wall/Pedestal etc.) installed in various buildings of the University i/c checking the unit with accessories for functionality tests, replacement of nut-bolts & locking pins/clips wherever reqd, oiling/greasing, cleaning, pasting of service/repair slips on fan and any other minor repair works required on site i/c labour, tools & takels charges as per standard practice and directions of EIC. Note: 1) This work also includes replacement of spare parts of fans like condensors, regulators, fan hooks as required during servicing and these spare parts will be provided by the University.2) This work excludes all major repair works like rewinding, replacement of bush/bearing etc. 34 Copper rewinding of existing burnt fans (Ceiling/ Exhaust/Wall/Pedestal Fans) under buyback of old copper incl. handling charges etc. as per standard practice. 35 Replacement of parts like bush/bearing etc. with new one of same size/rating under buyback of faulty one as per standard practice incl. handling charges. 36 Repairing of rotor/stator/shaft etc. of fans as required as per standard practice incl. handling charges. 37 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj 38 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects excluding replacement of batteries.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 39 14 Nos. 1 kVAOnline UPS 40 08 Nos. 2 kVA to 3 kVA Online UPS 41 08 Nos. 5 kVA to 6 kVAOnline UPS 42 02 Nos. 10 kVA Online UPS 43 06 Nos. 15 kVA to 20 kVA Online UPS 44 02 Nos. 40 kVA Online UPS 45 Replacement of following capacity faulty/dead SMF rechargeable batteries with new batteries of same rating/capacity along with connections, testing and commissioning etc. as required on site as per standard practice, under buyback offer. Make: Exide/Amaron/Luminous/HBLWarranty:minimum 02 years onsite or as per OEM, whichever is higher. 46 18 AH, 12 V 47 26/28 AH, 12 V 48 42/45 AH, 12 V 49 65 AH, 12 V 50 75 AH, 12 V 51 120 AH, 12 V 52 150 AH, 12 V 53 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj 54 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects.Note: This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons. 55 Repairing of 45 Nos. faulty Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 56 SH-II (d) Comprehensive AMC Work of HVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURajComprehensive AMC Work ofHVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 57 100 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in CIL Building. Make: Hitachi 58 40 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in VCS, Admin Building. Make: Hitachi 59 04 Nos. 11.0 TR capacity Ductable Air conditioning units with Scroll Compressor with R 410 A Refrigerant, vibration isolators etc. complete. Make: Hitachi 60 03 Nos. 5.5 TR capacity Ductable Air conditioning units with Scroll Compressor, R 410 A Refrigerant, vibration isolators etc. complete. Make: Carrier 61 03 Nos. Ceiling-mounted 3.0 TR Cassette Air Conditioning units complete. Make: Bluestar 62 400 Nos. Window/Split/Tower type air conditioners. 63 02 Nos. 30000 CFM, Air ducting system (ETAC) 64 04 Nos. 28000 CFM, Air ducting system (ETAC) 65 02 Nos. 10000 CFM, Air ducting system (ETAC) 66 02 Nos. 4000 CFM, Air ducting system (ETAC) 67 Repairing of faulty 100 Nos. Split ACs, 10 Nos. Tower Air-conditioners and 01 No. 5.5 TR Ductable AC, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 68 SH-II (e) Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets at CURaj. 69 Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower for operational purpose, labour, machinery, spare parts, Control Panel/DG Set Batteries, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: 1) This work includes operators in all three shifts on 24*7*365 basis at each ESS.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing i/c all B/C/D checks and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 70 SH-II (f) Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts at CURaj. 71 Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note:1) This work includes one lift operator in general shift on 24*7*365 basis in Admin Building.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 72 SH-III Comprehensive Annual Repair & Maintenance Work of Fire Hydrant System and Fire Alarm System installed at CURaj. 73 Comprehensive Annual Repair & Maintenance Work of all Fire Hydrant System installed in various building of the University (tentative buildings = 30 nos.) as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 74 Comprehensive Annual Repair & Maintenance Work of all Fire Alarm System and associated equipment installed in various building of the University as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 75 Repairing of existing non-functional Fire Hydrant System including associated equipment, installed in B1 to B7 Hostel buildings, KV Building and B/C/D type Staff Quarter Blocks of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 76 Repairing of existing non-functional Fire Alarm System including associated equipment, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 77 SH-IVComprehensive Annual Maintenance Contract for RO Plants/Purifiers. 78 The scope of work includes comprehensive annual maintenance and servicing of RO Plants/Purifiers and submitting a report after every visit. The scope of work includes checkup of each Unit/system and general cleaning, chemical cleaning of cartridge, if required, replacement of all type of membrane, all type of filters, all pipes, S.V., TDS Controller, all type of sensors, pump etc. as per requirements of the University during the CAMC Period. 79 Supply and Installation (under buy back) of Reverse Osmosis Plant of 50 LPH Capacity Make Eureka ForbesNote: Old Reverse Osmosis Plant of 50 LPH Capacity - Make Eureka Forbes will be the property of the Contractor. Hence contractor may be advised to quote their rates accordingly. 80 SH-VComprehensive Operation and Maintenance of IT Works. 81 Comprehensive Operation and Maintenance of installations IT Works (Operation & CAMC of Audio & Video Conferencing System, Networking items for LAN and Wi-Fi systems like Switches, Active & Passive network components, Smart class rooms Equipments including PA systems, Hardware and software maintenance of Computers, Laptops, Printers, Projectors, Servers), CCTV Systems. as per the details given below: 82 Hardware Items 83 Laptops : 84 Desktop System: 85 Server: 86 Printers: 87 LCD Projector: 88 CCTV System 89 IP Camera 90 DVR Camera 91 Switch (24 port) 92 Switch (8 port) 93 Switch (4 port) 94 42 Screen 95 32 Channel NVR 96 8 Channel NVR 97 4 Channel NVR 98 Surveillance Hard Disk 10 TB 99 Surveillance Hard Disk 4 TB 100 Surveillance Hard Disk 2 TB 101 Biometric Access Control Systems 102 Face Biometric Machine 103 Voice System 104 IP-PBXMachine 105 IP Phone 106 IP Phone DSS KEY 107 Data Networking System 108 Switch(48 Port) 109 Switch (24 Port) 110 Core Switch 111 LAN points 112 Audio Video Conferencing System 113 Group Video Conferencingdevice including camera, speakerphone with USB plug-and-play connectivity 114 PTZ Video Conferencing Camera 115 Smart Classrooms System including PA System 116 Smart Classroom equipped with, interactive screen 75/86 inch, audio systems, digital podium with mini PC, PTZ cameras and other related items 117 SH-VI Comprehensive Maintenance of Horticulture and operation & maintenance of Drip Irrigation System. 118 Horticulture Manpower in General Shift in all days except Sundays and holidays (Unskilled). All tools tackles shall be arranged by contractor within its quoted rates.• Complete maintenance of Trees, Plants and peripherals, shrubs, hedge, lawns, (Including cricket ground, hockey ground and football ground etc.) cemented potted plants, flower beds, creepers etc. within the campus of the Central University of Rajasthan.• Maintenance includes weeding, pruning, gap filling, watering, mowing of lawn, hoeing, hedge-clipping, application of insecticide & pesticide, top dressing of lawn with good earth and manure including other maintenance work as directed by the University from time to time.• Fertilizers, Manures, plant protection materials etc. will be provided by the contractor nothing extra shall be paid in this regard.Maintenance of Drip Irrigation System, (water sprinkler system installed at cricket, football and hockey grounds and another places of the University etc.) periodical checking of the system cleaning, oiling, greasing, routine maintenance, realignment, necessary safety arrangements & repair/ replacement of consumables such as Super flow screen filters, Gravel filters, Pressure relief valve, Non return valve, stainless steel pressure gauges,by pass valve PP, PVC control/ball valves, sub main flush valve, Reinforced nylon air release valve CPVC gate valves, super flow disc clean filters, PVC pipes and fittings etc. as per direction of Engineer-in-charge. This shall include all cost involved in maintenance except for electricity for operation, which shall be provided by the University free of cost. 119 SH-VIIMechanized Housekeeping Services, Garbage Collection & Disposal Services, and Pest Control Services at CURAJ. 120 ProvidingMechanized House Keeping Service include machine enabled cleaning, sweeping, wiping, dusting, moping, freshening, garbage collection, segregation & disposal, vacuum cleaning, scrubbing and any other similar tasks as assigned by CURAJ authorities from time to time.Consumable, like duster, Soap, chemicals, wipers, Phenyl and other cleaning materials for toilets and floor required as indicated in list under the scope of work etc.All façade glass should be cleaned once in a month including glass doors and windows.Providing pest Control Services, Rodent Control Services, Fogging & Fumigation against mosquito & larva, Fly management services, termite treatment etc. as per tender terms and conditions and directions of the University. 121 Termite Treatment: Termite treatment in the University based on IS:6313(Part-3)-1981 specification which consists of creating uninterrupted chemical barriers inside and all around the building. The treatment should be drill holes of 6mm as close as possible to the plinth, walls, junctions of the walls at an interval of 6 inches enough to reach the soil below 6 inches deep. Then chemical emulsion should be injected into these holes, which should be subsequently sealed using white cement match with floor colour all complete , The wall should be spray the chemical emulsion up to roof height wherever required complete. 122 SH-VIII Hiring Manpower with fixed remuneration through outsourced agency at CURaj. 123 Service charges per month per person(To be quoted for deciding the lowest responsive bid to award the work)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
8.
Agriculture #10131578 Price Bid
Supply Of Veterinary Instruments / Equipments / Chemicals / Reagents / Media For The Year 2021-22-2 100 Ml Pp Bottle With Rubber Bung & Aluminium Cap- Sterilized, Round / Rectangular Shape, Rubber Bung And Aluminium Cap To Fit The Bottle 3 300 Ml Pp Bottle With Rubber Bunk & Aluminium Cap Sterilized, Roundshape, Rubber Bung And Aluminium Cap To Fit The Bottle 4 Adsons Tissue Forceps Stainless Steel, Size-6 5 Ai Gun Auto Ss Lock Mini Compatible With 0.25 Ml French Mini Straw With Container Made Up Ofpvc 6 Ai Gun With Container Container Made Up Ofpvc / Pp To Pack Ai Gun, About 19” Ai Gun For Goat Length - 10 Inch Device Used For Depositing Of Semen Via 0.25 Ml Straw, Make - 304 Stainless Steel Easy To Use Lock And Unlock Sheath To Accommodate French Mini Straw 0.25Ml, Diameter - 0.15 Cm Diameter Match With Artificial Insemination. 7 Ai Gun For Goat Length - 10 Inch Device Used For Depositing Of Semen Via 0.25 Ml Straw, Make - 304 Stainless Steel Easy To Use Lock And Unlock Sheath To Accommodate French Mini Straw 0.25Ml, Diameter - 0.15 Cm Diameter Match With Artificial Insemination. 8 Ai Sheath Container Made From Pvc, Size- 19 Inch Length Inner Día Is 46 Mm 9 Ai Sheath For Goat Sterile, Individually Wrapped Outer Plastic Shells Which Fit Over The Gun Providing A Secure Seat For The Straw. Packs Of 50 Pieces. 10 Ai Straw Cutter Stainless Steel Made From Pvc, Non-Corrosive Plastic With A Stainless Steel Blade Which Cuts Off The Proper Length With A Push Of The Button 11 Allis Tissue Forceps 6, Ss 12 Artery Forceps 6 Curved Ss 13 Artery Forceps 6 Straight, Ss 14 Av Cone A Latex Director Cone With Rolled Ends For Use In An Artificial Vagina For Bulls. Approx. 270 Mm. 10-1 / 2 In. L X 2-1 / 2 In. Dia. At Opening, 5 / 8 In. Dia. At Tip, 9 Inch Long 15 Av Hose 10 Inches Long, 2.5” Dia Approx Fitted With Good Quality Brass Valve For Pouring Hot Water. The Brass Valve Should Be Leak Proof For Air And Water. The Rubber Body Should Be Slightly Pliable. Both The Edges Should Be Rounded, Smooth And Elevated To Hold The Rubber Liner. 16 Av Liner Made From Natural Latex Material, Washable And Reusable, Ample Length To Fit Over Ends Of Vagina And Also Provide Rubber Bands, 12 Inch Long 17 Babcock Tissue Forceps, Ss, 6 ( Each ) 18 Biohazard Bag, Hdpe, , 12X24 With Thickness 50Μm 19 Bio-Medical Waste Bin Plastic Waste Bin With Foot Pedal, Colour-Blue, White, Red, Yellow, 20Ltr Capacity 20 Bone Curette, 8, Ss 21 Bp Blade No.10-Ss, Sterile Individually Packed, For Handle No. 3 22 Bp Blade No.24-Ss, Sterile Individually Packed, For Handle No. 4 23 Bp Blade No.12-Ss, Sterile Individually Packed, For Handle No. 3 24 Bp Blade No.23-Ss, Sterile Individually Packed, For Handle No. 4 25 Bp Handle No.4 ( Approxm. 130 Mm ) Stainless Steel 26 Bp Handle No.3 Approxm.125 Mm. ) Stainless Steel 27 Breeder Thermometer Material - Glass, Accuracy - 0.1 Degree Celsius 28 Casting Rope Cotton 1 / 2 X 15 Yards 29 Casting Rope Cotton 1 X 15 Yards 30 Catgut No-1-0 , Chromic Catgut, Suture Length-76Cm 31 Catgut No-2-0 , Chromic Catgut, Suture Length-76Cm 32 Cell / Tissue Homogenizer • Ideal Homogenizer For Extraction From Samples Like Bacterial / Yeast Cells, Plant Tissues, Animal Tissues And Other Tough Samples • Accommodates Wide Range Of Screw Cap Homogenizing Tubes Sizing 3X2ml • Powerful Motor – Homogenizes The Most Challenging Samples • Designed To Generate Lesser Heat And Convenient Loading Capacity – 3X2ml Speed Range – 2800 To 4000 Rpm Run Time – 3 Second To 180 Second Pulse Mode On / Off Timer - 3 Second To 99 Second Operating Condition - 40C To 450C Weight – 2.8 Kgs Dimensions ( Lxwxh ) – 235 X 158 X 140 Mm 33 Chizzle Forceps 10, Ss 34 Cotton Apron , Brown For Vet Asst., Size- Xxl ( Each ) 35 Cotton Apron, Sky Blue For Vets, Size-Xl 36 Cotton Apron, Sky Blue For Vets, Size-Xxl 37 Cotton Apron, Sky Blue For Vets, Size- L 38 Cryo Box Polycarbonate, Autoclavable To Old 81 Cryo Vials Of 1.8 Ml And 4.5Ml Numbers Moulded Into Grid System In The Box Corresponds To Number Printed In The Lid. 39 Cryo Container 1.5Lt. Capacity 1.5 Liter Of Liquid Nitrogen .This Metal Container Is Meant For Doorstep Ai By Private Ai Practitioners And Should Be Sturdy 40 Cryo Container 100Lt. / Jumbo 12 Metal Liquid Nitrogen Storage Container 41 Cryo Container 35Lt. High-Strength Aluminium Alloy Liquid Nitrogen Container, Neck Diameter: About 50Mm, Loss Mass:0.29Liter / Day, Static Holding Time:123 Days 42 Cryo Container 3Lt. Capacity 3-4 Liters Of Liquid Nitrogen With Static Evaporation Loss Rate Of 0.135 Liters Per Day At Stp, Six Canisters With Od 38Mm, Height 120Mm. The Level Of Liquid Nitrogen From Bottom Should Be About 20Cms. The Neck Diameter Should Be 50Mm. This Container Is Meant For Doorstep Ai By Private Ai Practitioners And Should Be Sturdy. 43 Cryo Container 50Lt. Liquid Nitrogen Container 50 Liter, Neck Diameter:50Mm External:Diameter 500Mm, High 790Mm, Loss Mass:0.37Liter / Day Static Holding Time:134 Days 44 Cryo Gloves For Liquid Nitrogen Handling, Can With Stand Up To-170.C Temperature, Length - Upto 45 Cm 45 Cryo Gloves For Liquid Nitrogen Handling, Can With Stand Up To -170.C Temperature, Length-Upto 45Cm 46 Cryovessel With Wide Mouth For Storage Of Frozen Semen Straw 550 Ltrs With 80-100 Canisters For Storage Of Frozen Semen Straw 47 Crystoscope Set Of Light With Glass Slides For Observing Fern Pattern 48 Digital Ph Meter Ph Range -0-14, Resolution : 0.001 Ph, Temperature Range : 0.0 To 100ºc ( Manual Compensation ) Display : 31 / 2 Digit Led Display Power Supply : 230Vac ±10%, 50 Hz Calibration Check Facility & Calibration Error Indication For 7.00 & 4.00 Ph 49 Dip Stick For Measuring Liquid Nitrogen Made From Styrene, About 4 Ft In Length With Graduations In Inches For Measuring Liquid Nitrogen Manually 50 Disposable 3 Ply Face Mask Disposable 3 Ply Face Mask, Melt-Blown Cloth & Non-Woven Material, Blue With Adjustable Nose Strip ( Pe Wire, Metal Free ) , Flat / Round Elastic Ear Loop, Hypoallergenic / Non-Irritating Fibre Glass Free Fabric, Inner Layer Made Up Of White Soft Facial Tissue, Bacteria Filtration Efficiency ≥95%, Low Breathing Resistance-Delta P < 29, 4 Pa 51 Disposable Head Cap Surgeon’S Head Cap, Cotton, Green Colour 52 Douch Can E.I. Can With 2 Meter Long Rubber / Polythene Tube ( 1.5Cm Diam. ) With Blunt Ends And Controlled Nozzle 53 Dressing Forceps 6, Ss ( 2 Nos ) 54 Egg Incubator Electrically Operated, 500 No. Eggs Capacity For Incubation Of Eggs For Vaccine Production Without Brooder. Power-Dc 12V;Ac110 / 220V, Humidity Range-0~99%Rh 55 Empty French Mini Straw Pvc Straw Of Different Colours.Pack Of 2000 Straws ( 0.25Ml ) 56 Eye Hook ( Large ) Ss With Blunt Ends 57 Eye Hook ( Small ) Ss With Blunt Ends 58 First Aid Box General 59 Flexible Sivl Cryocan Filling Hose Stainless Steel Braided Transfer Hose, Material Grade- Ss316, 4-5Mts. Long 60 Forceps Specimen Holder Ss10 Length 61 Frozen Semen Straw Lifter Stainless Steel, L-Shaped. Designed To Lift Semen Straws With Vertical Serrations Made At Tip ( 10” ) 62 Full Hand Disposable Gloves Polythene Make, 36 Inch 63 Gel Pack / Ice Pack 1 Pkt ( 100Gm ) 64 Gel Pack / Ice Pack 1 Pkt ( 450 Gm ) 65 Glass Slides, Microscopic-Optically Clear, Distortion Free Surface 66 Gloves Latex- Disposable, ( Large And Medium Size ) 67 Gloves Nitrile- Disposable ( Large / Medium ) 68 Goblet ( 35Mm ) Pvc, Plastic Goblets 35 Mm Diameter, 118Mm Long For French Mini Straws, Should Be Made From Virgin Plastic Compound, Should Withstand Repeated Cooling To -196 Degree Centigrade And Thawing To Ambient Temperature. The Goblets Should Be Compatible With The Imported Make Straw Counting And Filling Machine 69 Goblet ( 65Mm ) Pvc, Plastic Goblets 65 Mm Diameter, 118Mm Long For French Mini Straws, Should Be Made From Virgin Plastic Compound, Should Withstand Repeated Cooling To -196 Degree Centrigrade And Thawing To Ambient Temperature. The Goblets Should Be Compatible With The Imported Make Straw Counting And Filling Machine. 70 Gum Boots Full Size ( In Pair ) Sizes-8, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 71 Gum Boots Full Size ( In Pair ) Sizes-9, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 72 Gum Boots Full Size ) ( In Pair ) Sizes-10, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 73 Gynaecology Aprons Size: M And L, Full Length Made Of Synthetic Material And Provided With Braided Cotton Ends For Tying With Pockets. 74 Haemocytometer ( Neubauers ) Thick Crystal Slide With The Size Of Glass Slide ( 30 X70 Mm And 4 Mm Thickness ) Double Improved Neubauer Counting Chamber, Leucocyte Pipette ( White Bulb ) , Erythrocyte Pipette ( Red Bulb ) , 16 Cm Transparent Silicone Tubing ( Colour Coded For Each Pipette ) , 0.4 Mm Glass Coverslip 75 Haemoglobinometer ( Sahlis ) Consist Of Comparator Box Which Has Brown Colored Glass On Either Side, Hb Pipette Which Is Marked Upto 20Mm3 ( 0.02Ml Blood ) , Tube With Markings Of Hb On One Side , Glass Rod , Dropper 76 Head Light Neutral Light Led, Compact And Lightweight, 90 Degree Adjustable Light Beam, Powered By A Single Aa Alkaline Battery, Hm23 Light Outputs 77 Hoof Cutter Made Of Carbon Steel Alloy And Has A Sharp Cut And Is Durable, 78 Hot Air Oven 0°C To 250°C Temperature, Uniform Air Circulation Across Chamber, Digital Temperature Controller Cum Indicator, Excellent Uniformity At High Temperature, Stainless Steel Inner Chamber, Corrosion Resistant Exterior, Fume Ventilation Points On Both Sides, Steel Wire Mesh Cable Trays, Over Temperature Protection, Toughened Glass Window, Power Supply- 220 Volts / 50 Hz, Single Phase 79 Hot Water Bath Stainless Steel Double Walled With 304 Grade. Temperature Should Be Controlled By Micro Processor Based On Digital Temp. Controller. Auto Water Low Level Water Cut Off. Temp. Range: 5 Deg. C Above Ambient To 95 Deg. C.Temperature Measurement / Control Accuracy Not Higher Than + / - 1°C. 80 I / V Saline Set Saline Set Meant For Intra Vinous Infusion Of Fluids 81 Insemination Gloves- Full Arm Length 82 Mastitis Detector Digital / Electronic With 4 Cups With Reading For 4 Quarter 83 Mastitis Kit Mastitis 4 Cup Padel, With Solution 500Ml ( 2 Kit Unit ) 84 Mayo Scissors , Ss, Straight, 6 85 Mayo Scissors Ss, Curved, 6 86 Mayo Scissors Ss, Straight, 8 87 Mayo Scissors Ss, Curved, 8 88 Metal Detector For Bovines The Machine Will Visually And Acoustically Indicate If There Is Any Type Of Metallic Foreign Body Inside The Stomach 89 Mosquito Artery Forceps 4Curved, Ss 90 Mosquito Artery Forceps 4Straight, Ss 91 Mouth Gag Large Ruminants, Ss 92 Mouth Gag Small Ruminants, For Dog, Ss 93 N-95 Mask 5 Layers With Nose Clips And Elastic Strip, Filters Out At Least 95% Of Very Small ( 0.3-Micron ) Particles When Properly Fitted And Donned, Minimal Leakage Occurs Around Edges Of The Respirator When User Inhales, 94 Needle Holder Ss, 6 95 Non Invasive Multiplexed Biomass Sensor System Automated, Continuous, Real Time Multi-Vessel Biomass / Od Monitoring With Working Volume Done To 10Ml, Biomass Sensitive Range-<0.01 To >600 Od Units, 12Mm Diameters, 96 Nylon Suture Coarse Fiber, In Hank Of 100 Threads ( Pkt ) 97 Olsen-Hegar Needle Holder, 6 With Cutting Edge 98 Peristaltic Pump-201V Notor-Stepper With Motor Torque-10Kg, Rpm-1 To 200, Tube Size- 1 To 8Mm, Flow Rate-0.8 To 1800Ml / Min, Discharge Pressure-2 Bar, Maximum Discharge Height-10Liters, Dimension- ( L-325Xw-170Xh-250 ) Mm 99 Peristaltic Pump-401V Notor-Stepper With Motor Torque-1 / 6Th Hp, Rpm-20 To 240, Tube Size- 8 To 19Mm, Flow Rate-250 To 20000Ml / Min, Discharge Pressure-3 Bar, Maximum Discharge Height-30Liters, Dimension- ( L-500Xw-250Xh-400 ) Mm 100 Petridsih Borosillicate Glass, 100Mm, 150Mm 101 Ph Meter, Bench Top Digital Ph Meter With Led / Lcddisplay, Range 0-14 Ph With 0.01 Resolution, Auto / Manual Calibration, Temperature Range 00-100°C Electrically Operated With Electrode And Electrode Holder. 102 Polydiaxonone Suture No.1-0 ( Pack Of 12 ) 103 Polydiaxonone Suture No.2-0 ( Pack Of 12 ) 104 Polyglactin Suture No-1-0 ( Pack Of 12 ) 105 Polyglactin Suture No-2-0 ( Pack Of 12 ) 106 Ppe Kit A ) Dangri- Disposable, Free Size Full Sleeve, Polypropylene Material 90 Gsm B ) House Gloves: Disposable, Isi Mark, 10 Nos C ) Shoe Cover: Disposable With Thick Padded Foot Base D ) Face Mask With Hepa Filter E ) Disposable Protective Glasses 107 Probang Metal 108 Rat Toothed Forceps 6, Ss 109 Rat Toothed Forceps, 8, Ss 110 Safety Goggles / Protective Eye Wear Moulded Of Soft Flexible Polyvinyl Chloride Covering Eyes , Nose And Have Vents To Reduce Fogging . The Front Lenses Is Made In Clear Acetate And Can Be Worn Over Regular Eye Glasses 111 Scalp Vein Set Sterile Butterfly Wing Luer Lock, 20G Pouch Pack / Blister Pack Set 112 Scalp Vein Set Sterile Butterfly Wing Luer Lock , 22G Pouch Pack / Blister Pack Set 113 Scissor Blunt 8, Ss 114 Scissors Straight Ss, 10 115 Single Pack Ai Sheath Single Pack , Sterilized To Fit 0.25 Ml Straw 116 Slide Warmer Temperature Range Ambient Temp. To 70° C I.E. Below The Melting Point Of Wax. The Temperature Is Thermostatically Controlled. The Body Is Made Out Of Thick Mild Steel Duly Finished In White Stoving Enamel / Powder Coated Paint With Mat Finished Color Combinations And Top Is Made Of Highly Polished Stainless Steel Sheet. To Work On 220V Ac 50 Hz Single Phase. Length X Width: A ) 30 X 25 Cm B ) 40 X 25 Cm 117 Spirit Lamp Spirit Lamp With Cap Made From Stainless Steel Supplied With Wick 118 Sponge Holding Forceps 10, Ss 119 Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non‐Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm ‐ Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation ‐ Dia. 900 Mm •Shell Thickness : 2 Mm ‐ Ss 304 •Tank Internal Surface Mirror Polished. Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, ‐1 To 10 Bar Pressure- 1 No. 120 Ss Tray Stainless Steel, 18 X 12 121 Sterilizing Drum / Dressing Bin Made Of Stainless Steel ( Grade: Ss 304 Or Ss-Ln ) , Sets Of Perforation On Drum Body, Slotted Belt With Clamp For Loosening Or Tightening Of Belt To Open Or Close The Perforations On The Body, The Clip When Clamped Will Keep The Belt In Fair Tension, Sizes- Dia × Height ( Inch ) - 9 X 9, Thickness: Heavy Gauge ( 0.6 To 0.7Mm ) , Shape-Round, Finish : Polished 122 Storage Rack For Cold Cabinet Detachable With Adjustable Heights, 6 Ft Length X 2 Ft Wide X 8 Ft Height, Light Class, 2 Mm Thickness, 304 L Grade Ss 123 Straw Cutter Made From Pvc, Non-Corrosive Plastic With A Stainless Steel Blade Which Cuts Off The Proper Length With A Push Of The Button, Easy To Disassemble And Wash Without Tools. 124 Surgical Tray With Cover Stainless Steel, Size- 12 X 10 125 Suturing Needle Size 7, Taper Point, 3 / 8 Circle, 50Mm Long, Ss 126 Suturing Needle Round Shaft, Straight, Taper Point With No Cutting Edge, Ss, 4 Long 127 Suturing Needle Size 10, Cutting Edge, 1 / 2 Circle, 55Mm Long, Ss 128 Suturing Needle Triangular Point With Cutting Edge On The Inner Curvature And Precision-Honed For Added Sharpness’S, 4 Long 129 Table Top Incubator ( Incubator Mini ) Temperature Range 5⁰ C To 60⁰ C With Powerful Fan To Circulate Air For Maintaining Uniform Temperature Inside Chamber, Double-Walled With Puff Insulation. The Inner Chamber Should Be Made By Non-Corrosive, Non-Magnetic Stainless Steel. The Outer Door Should Be Of Powder Coated Crca Steel, Double Door ( Plexi Glass Inner Door To Observe The Sample And Outer Door Powder Coated Crca Steel ) , The Compressor Should Have Cfc Free Refrigerant With Time Delay Switch-On, Digital Led Display Of Temperature. Safety Thermostat To Prevent Overheating With Audio-Visual Alarm Warning Of Temperature Variation, High Temperature Safety Cut Off & Alarms For High / Low Set Parameters, Electrical Requirement: 220-240 V With High Voltage Safety Cut-Off. 130 Tamponing Forceps Made Of Stainless Steel, Length-18 Inch The Tip Should Have Grooves To Grip. 131 Teat Surgery Instruments Teat Surgery Set Containing All Following Items In Dust Proof Cover With Zipper :- Furstenberg’S Teat Siphonwith Round Head And Side Openings , 9 Cms Length Nickel Platedof Diameter 2Mm Along Withstillet. 2 Pc. .2.5Mm Dia2pc. 3.0 Mm Dia1pc. 2.Hug’S Teat Tumor Extractorstainless Steel12.5 Cms Length X 4Mm Dia2pc. 3.Teat Dilator With Screw Action 17 Cms1pc 4.Teat Slitterwith Screw And 2 Blades Danish Pattern 19Cms Length , 3Mm Dia Nickel Plated1 Pc 5. Teat Slitter Swiss Model9.5Cms Length , 4 Mm Dia 1 Pc 6.Lichty Teat Knife With Sharp Point Made Of Stainless Steelto Cut The Extra Growth In Teat Canal. Total Length With Handle18 Cm. Made Of Stainless Steel Material 132 Teat Syphon Stainless Steel, Self-Retreating , Adjustable, 2Mm Outer Diam. 133 Tenaculum 6 Ss 134 Thaw Monitor Should Be Made Up Of Liquid Crystal Temperature Indicating ( 32 0C- 400C ) Device With Triple Laminated And Water Resistant 135 Thermometer, Digital Digital Display, Waterproof, With Alarm And Memory. 32ºc-43ºc In A Strong Plastic Case 136 Thermometer, Oval Oval- Mercurythermometer, Transparent, Range-35ºc-42ºc With 0.1ºc Increment 137 Towel Clip, Ss, 8Cm 138 Trocar Cannula Stainless Steel, 6 Inch Trocar With A Sharp Triangular Point And Handle, Inside The Hollow Tube ( Cannula Or Sleeve ) To Fit The Trocar, For Large Animals, 139 Trocar Cannula Stainless Steel, 4 Inch Trocar With A Sharp Triangular Point And Handle, Inside The Hollow Tube ( Cannula Or Sleeve ) To Fit The Trocar, For Smallanimals, 140 Tweezer Ss, Straight With Serrated Tips, 8 141 Vaccutainer With Needle & Needle Holder 10 Ml Capacity With Edta And Without Edta 142 Vaginal Speculum For Goat Ai Measurement: Length Of The Blades - 16 Cm, Maximum Opening - 8Cm, Working Diameter -4 Cm. Technical Specifications : Material - Stainless Steel, Rust Prevention Procedure -Passivation, Ultrasonic Cleaned - Yes, Lubricate - Yes, Usage - Both Hand, Test Performed - Boil Test, Performance Test, Shape Test, Packing - Individually Packed. 143 Wire Saw Ss, 1.5 M Length With 2 Handles 144 Chemicals Reagents Media 145 Alum ( Potassium Aluminium Sulphate ) Lr 146 10X Tae Buffer Molecular Grade 147 6 X Gel Loading Buffer Molecular Grade 148 Agarose Molecular Grade 149 Anthrax Rapid Test Kit 150 Avian Influenza Antibody Multi Valent Test Poultry Kit Detection Elisa Kit 151 Avian Influenza Virus Antigen Test ( Poultry ) Rapid Test Kit 152 Blood Genomic Dna Purification Kit 153 Blood Genomic Rna Purification Kit 154 Bq Rapid Test Kit 155 Cedar Wood Oil ( R.I. 0 To 1.5 ) Lr 156 D-256 Liq ( Microgen ) Lr 157 Dextrose Ar 158 Dna Ladder 100Bp 100Bp Dna Ladder 159 Dnase &Rnase Free Molecular Grade Water Molecular Grade 160 Dpx Mountant Lr 161 Early Pregnancy Detection Kit Enzyme Linked Immune Assay For Detection Of Early Preganancy-Associated Glycoproteins In Serum Or Plasma / Can Be Used From 28 Days Post Breeding 162 Edta Ar 163 Elisa Kit For Diagnosis Of, Goat Pox, , Rd, Ibd ( Antigen Detection ) Kit 164 Falcon Tube With Graduation 50 Ml Tube 165 Formalin / Formal Dehyde ( 37-41% W / V ) Ar 166 Glycerol-98%W / V Ar 167 Goat Pox Virus Antigen Rapid Test Kit Kit 168 Hand Sanitizer Lr 169 High Clean Liquid Soap Lr 170 High Clean Liquid Soap Lr 171 Hi-Sybr Master 2X Molecular Grade 172 Hs Rapid Test Kit Kit 173 Ibd Virus Antigen Detection Rapid Kit Kit 174 Iddex Biochemical Kit For Serum-Glucose Estimation Kit 175 Iddexbiochemical Kit For Serum-Albumin Estimation Kit 176 Iddexbiochemical Kit For Serum-Albumin Estimation Kit 177 Iddex Biochemical Kit For Serum-Calcium Estimation Kit 178 Iddexbiochemical Kit For Serum-Calcium Estimation Kit 179 Iddexbiochemical Kit For Serum-Cholesterol Estimation Kit 180 Iddexbiochemical Kit For Serum-Cholesterol Estimation Kit 181 Iddexbiochemical Kit For Serum-Creatinine Estimation Kit 182 Iddexbiochemical Kit For Serum-Creatinine Estimation Kit 183 Iddexbiochemical Kit For Serum-Magnesium Estimation Kit 184 Iddexbiochemical Kit For Serum-Magnesium Estimation Kit 185 Iddexbiochemical Kit For Serum-Urea Estimation Kit 186 Iddexbiochemical Kit For Serum-Urea Estimation Kit 187 Lubricant For Vaginal Speculum Non-Spermicidal, Sterile Lubricant Used For The Lubrication Of The Vaginal Speculum Prior To Its Insertion ( 50Gmpack ) 188 Lysol 500 Ml 189 Mb Grade Water Molecular Grade 190 Methanol / Methyl Alcohol ( Acetone Free ) Lr 191 N / 10 Hcl Lr 192 Phenyl Mercuric Nitrate ( Pmn ) Lr 193 Phosphate Buffer Saline ( Ph 7.2 ) Ar 194 Potassium Iodide Lr 195 Ppr Virus Antigen Detection Rapid Test Kit Kit 196 Probe Based Animal Theileria Detection Pcr Kit Kit 197 Qiaamp Viral Rna Minikit Cat No 52904 Kit 198 Rd Virus Antigen Detection Rapid Kit- Kit 199 Rectified Spirit Lr 200 Rnase Jap Kit 201 Rotheras Mixture Lr 202 Sabrauods Dextrose Agar Bacteriological Grade 203 Sabrauods Dextrose Broth Bacteriological Grade 204 Silvicide / Peroxide Silver Ar 205 Sodium Chloride Ar 206 Sodium Hydroxide ( Pellets ) Ar 207 Sodium Nitropruside ( Dehydrated ) Lr 208 Standard Nutrientbroth For Hsv Subculture Bacteriological Grade 209 Steri Sweep Molecular Grade 210 Sterile Swab 100 Per Pkt 211 Sulphric Acid ( Conc ) Lr 212 Super Script™ Iii Platinum™ One-Step Qrt-Pcr Kit Catalog Number:11732020 Molecular Grade 213 Taq Pcr Master Mix Molecular Grade 214 Teepol Molecular Grade 215 Thioglycollate Broth With Liver Extract ( Bqv Subculture ) Bacteriological Grade 216 Tissue Genomic Dna Purification Kit Molecular Grade 217 Tissue Genomic Rna Purification Kit Molecular Grade 218 Tris Buffer Ar 219 Trypsin ( Bovine ) Ar 220 Trypsin ( Porcine ) Ar 221 Urine Test Stripsfor Idexx Vetlab Ua Analyzer 1Pk 222 Wide Mouth Sterile Sample Collection Bottle 30-50 Ml Capacity 223 Xylene Ar 224 Amc ( Only The Cost Of Amc To Be Mentioned ) 225 Cell / Tissue Homogenizer • Ideal Homogenizer For Extraction From Samples Like Bacterial / Yeast Cells, Plant Tissues, Animal Tissues And Other Tough Samples • Accommodates Wide Range Of Screw Cap Homogenizing Tubes Sizing 3X2ml • Powerful Motor – Homogenizes The Most Challenging Samples • Designed To Generate Lesser Heat And Convenient Loading Capacity – 3X2ml Speed Range – 2800 To 4000 Rpm Run Time – 3 Second To 180 Second Pulse Mode On / Off Timer - 3 Second To 99 Second Operating Condition - 40C To 450C Weight – 2.8 Kgs Dimensions ( Lxwxh ) – 235 X 158 X 140 Mm 226 Cryovessel With Wide Mouth For Storage Of Frozen Semen Straw 550 Ltrs With 80-100 Canisters For Storage Of Frozen Semen Straw 227 Non Invasive Multiplexed Biomass Sensor System Automated, Continuous, Real Time Multi-Vessel Biomass / Od Monitoring With Working Volume Done To 10Ml, Biomass Sensitive Range-<0.01 To >600 Od Units, 12Mm Diameters, 228 Peristaltic Pump-201V Notor-Stepper With Motor Torque-10Kg, Rpm-1 To 200, Tube Size- 1 To 8Mm, Flow Rate-0.8 To 1800Ml / Min, Discharge Pressure-2 Bar, Maximum Discharge Height-10Liters, Dimension- ( L-325Xw-170Xh-250 ) Mm 229 Peristaltic Pump-401V Notor-Stepper With Motor Torque-1 / 6Th Hp, Rpm-20 To 240, Tube Size- 8 To 19Mm, Flow Rate-250 To 20000Ml / Min, Discharge Pressure-3 Bar, Maximum Discharge Height-30Liters, Dimension- ( L-500Xw-250Xh-400 ) Mm 230 Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non‐Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm ‐ Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation ‐ Dia. 900 Mm •Shell Thickness : 2 Mm ‐ Ss 304 •Tank Internal Surface Mirror Polished. Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, ‐1 To 10 Bar Pressure- 1 No.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 11
9.
Home Affairs #8870397 Technical Bid
Annual Maintenance Contract Of Window Type , Split Type And Tower Type Air Conditioners Installed At Ss Bn , Itbp Saboli , Sonepat ( Haryana ) For The Year 2021 22 Amc Of Window Type , Split Type And Tower Type Air Conditioners Installed At Ss Bn , Itbp Saboli , Sonepat ( Haryana ) For The Year 2021-22 , Amc Work Of Split Type , Window Type And Tower Type Acs , 1 . 0 To 4 . 0 Tonne : Running And Comprehensive Maintenance Of 1 . 0 To 2 . 0 Tonne Window Type Air-Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 24 Ac X 7 Month=168 Ac ) , Running And Comprehensive Maintenance Of 1 . 0 To 2 . 0 Tonne Spilt Type Air Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 24 Ac X 7 Month=168 Ac ) , Running And Comprehensive Maintenance Of 4 . 0 Tonne Tower Type Air-Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 3 Ac X 7 Month=21 Ac )
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
10.
Defence #8411800 AOC
Tender For Day To Day Maintenance Misc Repairs At 42 Weu And Repairs To Cooling Appliances Internal Electrification And Water Supply Distribution Line At 42 Weu At Sac Under Ge Af Tvm; 1 Day to day maint at Pkt A, B, D & E and petty repair services at HQ SAC Trivandrum. 2 Checking of joinery (wooden/steel) iron/aluminium mongery, pelmet box, door springs etc requiring carpentry work and carrying out minor repairs such as tightening of screws/nails, minor adjustment of joinery, door /windows by means of planer/chisling etc. including petty repairs material like screws/nails, plug etc. to make it functional.Note : Any items required to be replaced shall be paid under respective items and in that case this items shall not be measured and paid. 3 S&Fin repairs 25mm dia decorative anodised Aluminium curtain rodsincluding supporting brackets and end caps/dome complete all as specified and directed 4 Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins or spring clips and providing and fixing new clips or pins. complete all as specified and directed 5 S&F in repairs looking mirror 600mmx450mm beveled edge 5mm thick selected quality glass, mounted on 6mm thick commercial plywood, aluminum frame around and fixed to wooden plugs with chromium plated brass screws and cup washers complete. 6 S&F in repairs aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.complete all as specified and directed 7 S&F in repairs 150mm extruded brass handles fabricated and polishedcomplete all as specified and directed 8 S&F in repairs 150 mm aluminium handles, cast type, anodised.complete all as specified and directed 9 S&F in repairs 125 mm aluminium handles, cast type, anodised. complete all as specified and directed 10 S&F in repairs 200 mm long brass tower bolts complete all as specified and directed 11 S&F in repairs 200 mm long aluminium anodised barrel tower bolts of extruded section. complete all as specified and directed 12 S&F in repairs 150 mm long aluminium anodized barrel tower bolts of extruded section. complete all as specified and directed 13 S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges. complete all as specified and directed 14 S&F in repairs stainless steel butt hinges medium weight 100 mm long fixed to pressed steel/angle iron frames by welding. complete all as specified and directed 15 S&F in repairs Aluminium CP towel ring fixed with flanges and brackets as per specifications complete all as specified and as directed 16 S&F in repairs to decorative 150mm brass mortice lock complete all as specified and directed 17 S&F in repairs decorative brass handles (size not exceed 300mm) for doors including mortice lock complete all as specified and directed 18 M & L 18/19mm thick Prelaminated plywood, prelaminatedon both sides with decorative choice laminations, fixed with screws to incupbords, warddrops, kitchen covered cabinetetc around the plywood/ teakwood lipping shall be finished with two coats of French polish. 19 Taking down chowkats or frames (without taking off shutters from frame) not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed 20 Taking down chowkats or frames (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.)complete all as specified and directed. 21 Taking down Shutters of any description exc 1.0 sqm and n.exc 2 sqm each, resecuring or easing and refixing in the same opening, including finishes complete all as specified and directed 22 Taking down Shutters of any description n.exc 1 sqm each, resecuring or easing and refixing in the same opening, including finishes complete all as specified and directed 23 S&F plain, solid, 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with pinned at joint etc complete. 24 S&F 75 mm longstainless steel butt hinges, medium weight, cold rolled and fixed. complete all as specified and directed 25 S&F 100 mm long stainless steel butt hinges, medium weight, cold rolled and fixed. complete all as specified and directed 26 S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. complete all as specified and directed 27 S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. complete all as specified and directed 28 S&F 100 mm long aluminium handles, cast type, anodised and fixed. complete all as specified and directed 29 S&F 150 mm long aluminium handles, cast type, anodised and fixed. complete all as specified and directed 30 S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring,size 140 mm.anodised with hard drawn steel spring overall length suitable for aluminium/wooden door complete all as specified and directed 31 S&F in repairs floor door stopper of brass body and tongue, anodised with hard drawn steel spring,size 140 mm.anodised with hard drawn steel spring overall length suitable for aluminium/wooden door complete all as specified and directed 32 S&F in repairs door closers of aluminium die cast bodyhydraulically regulated designation No 2, universal type, suitable for door shutters of 800 to1000 mm in width and of weight between 61 to 80 kgs and fixedcomplete all as specified and directed 33 S&F 4.80 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in squaresexceeding 0.50 Sqm in each pane.complete all as specified and directed 34 Checking and attending to water leakage from taps, flushing cisterns, wash hand basins and other sanitary fittings/fixtures and any obstruction to water supply, requiring plumber work andcarryout minor repairs such as replacement of washers, check nuts, tightening of fittings of flushing cistern etc including petty materials like washers of all sizes, thread(shoot), M-seal, screws, nails to make water supply/ plumbing lines functional and leak proof.Note :Any item required to be replaced shall be paid under respective item and in that case this above item shall not be measured and paid. 35 S&F in repair pillar taps, fancy type chromium plated copper alloy, with capstan heads, chromium plated, fancy type ,screwed down high pressure, with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe of dia 15 mmcomplete all as specified and directed. 36 S&F in repairs 15 mm stop valves/Angle cock, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipecomplete all as specified and directed 37 S&F in repairs 15 mm CP fancy type bib tap cast copper alloywith crutch or butter fly handle, scewed down, screwed for iron pipe or for brass ferruleand fixedcomplete all as specified and directed 38 Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm diacomplete all as specified and directed. 39 S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm longcomplete all as specified and directed 40 S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mmcomplete all as specified and directed 41 S&F in repair C.P. grating 100mm square/round with or without holecomplete all as specified and directed 42 S&F in repairs 32 mm dia PVC waste pipe for WHB complete all as specified 43 S&F in repairs 40 mm dia PVC waste pipe for sink, complete all as specified 44 S&F in repairs stainlesssteel toilet paper holder fixed with wooden gutties and screws to wall surfacescomplete all as specified and directed 45 S&F in repairs stainless steel soap tray fixed with wooden gutties and screws to wall surfaces. complete all as specified and directed 46 S & F in repairs, vitreous china WHBwhite, flat back, size 550x400mm with brackets, inc. cutting for & pinning in ends of brackets, inc. waste fitting, PTMT 32mm dia and pillar taps of PTMT 15mm dia complete all as specified and directed. 47 S&F in repair 10 ltr capacity PVC valveless, syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connection to pipe but fixed complete all as specified. 48 Cleaning ofwater tank capacity 500 ltrs and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed. 49 Cleaning of water tank capacity 1000 ltrsand removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed. 50 S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed. 51 S&F in repairsPVCwater tank cover of any pattern,colourand any size complete all as specified and directed. 52 S&F in repairs health faucet, CP with flexible pipe of bore 15mm with necessary holder , screws and fasterens fitted to wall complete all as specified and directed. 53 Supply & fixed (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges and Health Faucet with pipe complete all as specified 54 S & F in repair 3 layer (white colour) 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 55 S & F in repair 3 layer (white colour)750 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 56 S & F in repair 3 layer (white colour)1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 57 S & F in repair 25 mm bore,ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed .(Minimumweight 15mm-142 gms/20mm -210 gms/25mm -455 gms/40 mm-690 gms) complete all as specified and directed 58 S&F in repairs spindle for stop cock complete all as specifed and directed. 59 Cleaning of pipes of any dia after opening of bib taps, stop cock, angle cock, pillar taps and gate valve etc and refixing in same position after cleaning of pipes complete all as specified and directed. 60 S&F in repairs tank connector, PVC suitable for fixing to outlet pipe of any description and 32mm dia bore commplete all as specified and directed. 61 S&F in repairs PVC gate valve with handle, fixed both end for PVC pipe of 32mm dia bore complete all as specified and directed. 62 S & F in repairs 125 mm size chromium plated brass shower rose with or without swivel joints and swivel arms for fixing with 15 mm dia bore pipe complete all as specified and directed. 63 S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 64 S & F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 65 M&L for preparation of new woodensurfaces of any description, not otherwise described over 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of pinkprimercomplete all as specified and directed 66 S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed in wooden windows, doors and upvc windows with beading, aluminium wire staples and necessary arrangement also including necessary scaffolding wherever is required Note : Work in G+4 building Scaffolding shall be included in quoted rate complete all as specified and directed. 67 Dismantling of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etccomplete all as specified and directed 68 M&L for Granite (of any type) work ,20 mm thick, (table rubbed and polished) in steps jambs , pillars ,window cills ,cooking platforms ,and the like in cement mortar (1:4) including pointing in white cement (1;2) using marble dust with admixture of pigment to match with shade of granite including 10 mm thick screed bed in CM 1:4 complete all as specified and directed 69 Repair to aluminium door or window of any size, shape and description including easing, cutting, drilling, including provn of parts such as rubber gasket, blanket cloth, etc to make door or window fully functional complete all as directed by Engr-in- Charge. 70 Taking down cement or cement lime plaster of any description on brick or stone walls, ceilings etc.including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed 71 M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including finished the surface even and smooth with out using extra cement complete all as specified and directed. 72 M&L for rendering 15mm thick on fair face of brick work or concrete surface in CM 1:6including finished the surface even and smooth with out using extra cement complete all as specified and directed. 73 M&L for rendering 5mm thick on fair face of brick work or concrete surface in CM 1:3including finished the surface even and smooth with out using extra cement complete all as specified and directed. 74 M&L for preparation of new plastered surface of wall and applying two coats of oil emulsion distemper on wall over a coat of primer complete all as specified and directed. 75 M&L for preparation of new plastered surface of wall and applying two coats of weather coat paint over a coat of primer complete all as specified. 76 M&L for preparing new plastered surface of ceiling and applying two coat of white wash on ceiling all as specified and directed 77 S& F in repairs basin mixer with 450mm braided connection pipecomplete all as specified and directed by Engr-in-Charge.Make :Jaquar/CERA/Prayag or equivalent 78 S& F in repairs brass chormium plated 3 in 1 wall mixer wth the provision of overhead shower and telephonic shower arrangementcomplete all as specified and directed by Engr-in-Charge.Make :Jaquar/CERA/Prayag or equivalent 79 M&L for arresting Leakage of joint of UPVC/PVC/CPVC pipe of any size with solutioncomplete all as specified and directed 80 Removing basin mixer/ wall mixer and refixing in the same position after repairs/replacement of washer/plunger for arresting leakages including cleaning etc complete all as specified and directed. 81 Taking down glass corner shelf/straight glass shelf and refixing with new CP bracket and fitting with screws, complete all as specified and directed. 82 Fixing only Bib tap 15mm complete all as specified and directed. Note : Item to be procured from 83 Fixing only 600mm towel rail complete all as specified and directed 84 Fixing only 150mm Aluminium handle complete all as specified and directed 85 Fixing only 15mm concealed stop cock complete all as specified and directed. Note : Item from Sl No 81 to 84 should be issued under Schedule - B 86 Dismantling of broken laterite tile including cement mortar and fixing of new laterite tile of any size (as per site) over CM 1:3 on vertical surfaces complete all as specified and directed. 87 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similarpattern roof coverings complete all as specified and directed. 88 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 89 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick but except sheeting of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 90 Taking down of rain gutter pipe and refixing after cleaning and including brackets/fittings wherever is rquired complete all as specified and directed 91 Removing urinal waste coupling & pipe and refixing after arresting leakage including cleaning of waste coupling, complete all as specified and directed 92 Repairs to broken water pipe line including fittings as required, complete all as directed by Engr-in-charge. Note : Contractor must employ Plumber at urgent basis whether it may be day or night failing to which penalty will be imposed against the contract amount 93 Removing Push stop cock of urinal and refixing after replace plunger/washer including cleaning complete all as specified and directed. 94 M&L for removal of tree/bush from holes in walls and repair with CM 1:3 including WPC compound and including necessary scaffolding wherever is required, complete all as specified and directed. 95 Taking down Toughened glass door/Partition any size and refixing after making good including replacements of handles, brackets and necessary fittings wherever is required,complete all as specified and directed. 96 S&F in repairs aluminium weather strip with Nylon brush insert suitable for bottom of door shutters of wooden/aluminum all as specified and directed. 97 S & F in repairs Brass, 2 lever, locks, drawer, grade-I of 50 mm size complete all as specified and directed. 98 S & F in repairs mild steel 2 lever mortice lock, vertical type 100 mm size complete all as specified and directed. 99 S & F in repairs mild steel 4 lever mortice lock, vertical type 100 mm size complete all as specified and directed. 100 S&F in repairs 75mm long half folded auto hingescomplete all as specified and directed. 101 S&F in repairs venetian blind using cotton/Nylon fabric of size as required for windows/ Ventilators horizontally rolling up and down with double layer cloth including rolling device on top and power coated aluminium double layer pipe at bottom, incl operating rope etc all as specified and directed. 102 S&F in repairs bathroom cabinet with mirror 250x400 mm size, complete all as specified and directed. 103 S&F in repairs Solar control film 50micron reflective type sticked to glass panes as per instructions of manufacturers all as specified and directed. 104 S&F in repairs flush pipe of Polyethylene low or high density PVC 32mm dia for low level including fixed to WC and cistern complete all as specified and directed. 105 Taking down towel rail of any description from the wall and refixing after tiling work complete all as specified and directed 106 Taking down PVC cabinet of any description from the wall and refixing after tiling work complete all as specified and directed 107 Repairs only to flush pipe, soil waste pipe of WC for arresting leakage by providing bushes, washers, white cement, putty etc complete all as specified and directed. 108 Arresting leakage from joints between sink and granite slab by providing white cement, putty, M Seal etc complete all as specified and directed. 109 Repairs only to high/low level flushing cistern and arresting leakage of its internal fittings/washers complete all as specified and directed. 110 S&F in repairs internal fittings such as ball valve and float for flushing cistern complete all as specified and directed. 111 S&F in repairs complete set ofinternal fittings of Cascade type EWC for arresting leakage complete all as specified and directed. 112 S&F in repairs PVC eaves gutters half roundwith rounded edges of dia 110mm thickness of sheet 1.25mm complete all as specified and directed 113 S&F in repairs PVC eaves gutters half roundwith rounded edges of dia 75mm thickness of sheet 1.25mm complete all as specified and directed 114 Certain repairs/ Maintenance to complaints of B/R works and internal watersupply, sanitary fitting at 42 WEU at AF area TVM 115 Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing . 116 S&F unplasticised PVC pipes 20 mm bore of prerssure rating 10 kgf/sqcm fixed complete to wall, ceiling or in floors any type of pipe 117 Supply andfixed in repairs Vitreous chinawash down water closet pan (Pedestal pattern), white,excluding flushing cistern 118 S & Fin repairs 200 mm long aluminium, anodised, barrel tower bolts of extruded section, ISI marked, complete all as specified and directed. 119 S&F in repairs extruded aluminium alloy handles, fabricated type, anodised of size 150 mm long complete all as specified and directed. 120 S&F plain sheet glass 3 mm thick ordinary quality and glazing with oil putty/beading etc n.exc 0.50 Sqm each all as specified including removal of old broken glass 121 S&F in repairs Vitreous China wash basin, white, flat back, size 550x400excluding taps, waste, chain and plug andporcelainstopper but including brackets complete all as specified and directed 122 S&Fixed in repairs looking mirror 600x450 mm size Covered with aluminium frame with ply wood/black board/AC building board fixed with screw 123 S & Fixed in repairs PVC (SWR) Floor trap of 75 mm outlet plain with grating including jointing with solvent cement. 124 S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed on walls 125 S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints lfixed on walls 126 S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, fancy type, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe. 127 S & F Brass chromium plated showerrose 125mm size with or without swivel joints any size including fixing to steel pipe or union 15mm bore,fixed in repair. 128 Supply and fix PVC (SWR) branch piece double(double Y) equal or unequal 110mm dia 129 Supply and fix PVC (SWR) bends 75mm diaany radius. 130 Supply and fix PVC (SWR) bends 110mm diaany radius. 131 Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing ,removing serviceable tiles to store and rubbish off the premises. 132 M&L cement concrete type B0, 1:2:4 25 mm thick using 12.5 mm graded aggregate as in sub base for floor. 133 M&L Screed bed or bedding layerin cement mortar 1:4 15mm thick for laying floor finishes 134 S & F coloured ceramic tiles 7 t0 8mm thk (square /Rectangular ) area of each tile exc 0.06 sqn and n.exc 0.11 sqm ,in floors etcset and jointed in neat cement slurry and pointed with white cement or pigment to match with the shade of the tilesall as specified and as directed byEngineer-in-Charge. 135 M/L10mnm thick plastering in cement mortar 1:4 as backing coat for receiving finishes as skirting /dado. 136 M&L Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 137 S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with aluminium wire staplescomplete all as specified and directed. 138 S & F in repair alumimum extruted section body door closer hydraulically regulated, designation No 2, universal type, suitable for door shutters of 801 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 139 S&F mild steel work as framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 140 S&F in repairs stop cock fancy type cast copper alloy (concealed type) 15 mm borescrewed down high pressure, with crutch or butter fly handle screwed both ends for pipe or for unions complete all as specified and directed by Engineer in charge. 141 Repairs to drain, fencing, compound all/retaining wall, footpath and cleaning of septic tank, manholes sewage line at 42 WEU at AF area Trivandrum. 142 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in CM 1:6, complete all as specified and directed. 143 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in CM 1:4, complete all as specified and directed. 144 M&L forPre-cast cement concrete block (PCC 1:3:6 Type C-1) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. 145 M&L for Boulder pitching, pitching is grouted with cement and sand mortar 1:6, complete all as specified and directed.Note : Thickness of stone shall be 20cm. 146 M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 complete all as specified and directed. 147 M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 (Except stone) complete all as specified and directed. 148 Demolition of brickwork/blockwork or stone/ boulder masonry, built in cement or cement lime mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 149 M&L for chequered cement concrete tiles 300x300x20mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and no pigment complete all as specified and directed. 150 M&L 75mm thick PCC 1:4:8 type D2, using 40mm graded stone aggregate as in floors complete all as specified and directed. 151 M&L for 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed. 152 Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. 153 S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment. complete all as specified and directed. 154 -ditto- same as tem No.153 butexcept tiles complete all as specified and directed. 155 Supply and spreading coarse aggregate from 12.5mm to 4.75mm not exc 25cm thick complete all as specified and directed. 156 Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 15mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government 157 Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 15mtr but not exceeding 30mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system by mechanically sewage suction pump making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government 158 CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 75mm dia pipe in vertical walls/floors complete all as specified and directed. 159 CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 110mm dia pipe on vertical walls/floors complete all as specified and directed. 160 Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers, refixing manhole covers and for making good damaged surfaces of sorroundings of nahani trap, Gulli trap/floor traps etc with CM 1:3 or white cement complete all as directed by Engineer in Charge. Note :- Obtained waste materials shall be disposedto a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. 161 Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers andrefixing manhole covers, complete all as specified andas directed by Engineer-in-Charge. Note :- Obtained waste materials shall be disposedto a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. 162 S&F in repairs150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 163 M&L for cement concrete bed to drain pipe 150 mm dia in cement concrete 1:3:6 type C2 including packing under the haunching on sides all as directed and specified 164 S&Fin repairs 50mm bore Unplasticized PVC pipes of pressure rating 10 kgf/sqcm in repairs complete all as specified and directed 165 S&Fin repairs 75 mm,bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. 166 S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. 167 S&F in reapirs PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement and making good the surfaces all as directed and specified 168 S & F in repair 110 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . 169 S & F in repair 110 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . 170 S & F in repair 75 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . 171 S & F in repair 75 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . 172 Supply and fixed in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) sizeof cover 600 x 600mm/ 700 x 700mmconfirming to IS 12592, fixed in cement concrete 1:2:4, complete all as specified and directed. 173 Maint/ Repair to cooling appliances refrigeration at HQ SAC under GE (AF) Tvm 174 M&L Servicing of indoor unit of split type AC of 1.0 to 3.0 Ton Capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection all as directed. 175 M & L for servicing of outdoor unit of Split type air conditioner of1.0 to 3.0 Ton capacity any make by compressed air and water washing,descaling of condeser coil and oiling of outdoor fan motor, checking and tightning of all the electrical connections, nuts, bolts, washers all as specified and as directed. 176 M & L for painting of outdoor unit of Split type air conditioner of 1.5/2.0/3.0 ton capacity any make including preparation of old painted surfacecomplete and painting with one coat of Synthetic enamel paint complete in position all as specified and as directed. 177 M& L for stickering of MES/SM Nos on indoor and outdoor unit of any type of air conditioning in any location all as directed. 178 M& L for Removing the Split type AC 1.0 ton to 2.0 Ton, by taking out from the existing position after pumping down gas from position with frame, outdoor / indoor unit carefully, shifting to new position, cutting opening wall of required size & fix in new position, topping up of gas and making good distrubed surface of wall opening by plastering and appling white wash including closing the old opening making good distrubed surface plastering and appling white wash all as required and directed 179 M& L for Removing the Split type/ tower / cassette typeAC 3.0 ton to 4.0 ton capacity after pumping down gas from position, refixing to new position alongwith and charging of gas in the compressor after rectifing leak and rat cutting complete all as directed. 180 Supply and charge of gas R-410/R32 for inverter typre split AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. 181 Supply and charge of gas R22/R134a to Split AC,Tower AC, Cassette Type AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. 182 M&L for taking out old unserviceable capillary and stainer from refrigerator and supply and fix new capillary & stainer of any capacity.all as specified and as directed. 183 All as per item No 182 above but for inverter typre split AC and split type AC 1.0/1.5 /2.0 Ton capacity. 184 Servicing of refrigerator by air blowing, cleaning of condensor coil, rubber bedding & checking and tightning the electrical connection all as directedof capacity 165to 430 Ltrs all as specified and as directed. 185 Servicing of water cooler by air blowing, cleaning of condensor coil, checking and tightning the electrical connection all as directed for water cooler of capacity 40/80 ltrsall as specified and as directed. 186 Supply and fix in replacement of outdoor capacitor 36 + 5% uFD 187 Supply and fix in replacement of outdoor capacitor 46 + 5% uFD 188 Supply and fix in replacement of outdoor capacitor 62 + 5% uFD 189 Supply & replace timer switch for refrigerator of any capacity all as specified and directed. 190 Supply & replace bimetal switch for refrigerator of any capacity all as specified and directed. 191 Removing defective over load protector and supply and fixing new over load protector for Deep freezer/ refrigerator of any capacity and testing completeall as specified and as directed. 192 Supply and fix in replacement of defective fan motor with new fan motorsuitable for water cooler/deep freezer of any capacity and testing complete all as directed. 193 All as per No 192 above but forouter unit of split AC 1.5 Ton capacity all as specified and directed. 194 All as per No 192 above but forouter unit of split AC 2.0 Ton capacity all as specified and directed. 195 All as per No 192 above but forouter unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. 196 All as per No 192 above but forouter unit of inverter type split AC of 2.0 Ton capacity all as specified and directed 197 All as per No 192 above but forinner unit of split AC of 1.5 Ton capacity all as specified and directed. 198 All as per No 192 above but forinner unit of split AC of 2.0 Ton capacity all as specified and directed. 199 All as per No 192 above but forinner unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. 200 All as per No 192 above but forinner unit of inverter type split AC of 2.0 Ton capacity all as specified and directed. 201 All as per No 192 above but swing motor of split AC 1.5 /2.0/3.0 Ton capacity all as specified and directed. 202 M&L for rewinding of defective outdoor unit fan motor of split type AC 1.0/1.5/2.0 ton capacity any capacity and testing complete all as directed. 203 Removing and Repairs to electronic control PCBfor split type AC 1.0/1.5/2.0 ton capacity of existing make all as directed. 204 All as per item No 203 above but for mega split, towerAC type AC 3.0/ 4.0 ton ton capacity all as specified and directed. 205 All as per item No 203 above but forinverter type split AC of 1.0/1.5 ton capacity (outdoor & indoor) of existing make all as directed. 206 Supply and fix in repairs electronic control PCB with panel for 3.0/ 4.0 ton Tower/cassette type AC of existing make all as directed. 207 Supply and replace electronic control PCB for Smart Inverter Refrigerator all as directed. 208 Supply and replace sensor / anti ice thermostate for split type ACof any model all as directed. 209 Supply and replace remote unit for split type ACof any model all as specified and directed. 210 Supply and replace remote battery 1.5 Volts for split type ACof any model all as specified and directed. 211 supply and fix in repairs compressor suitable for split type AC 1.5 Ton capacity by removing unserviceable compressor after cutting the refrigerant line including supply and fixing new hermetically sealed compressor unit suitable to operate on 230 volt AC including connecting back the suction & discharge refrigerant lines, vaccumising charging of refrigerant testing and commissioning for smoot functioning all as specified & directed. 212 All as per item No 211 above, but for 2.0 Ton capacity all as specified and directed. 213 All as per item No 211 above, but for 4.0 Ton Tower AC capacity all as specified and directed. 214 All as per item No 211 above, but for inverter type split AC of 1.5 Ton capacity all as specified and directed. 215 All as per item No 211 above, but for inverter type split AC of 2.0 Ton capacity all as specified and directed. 216 All as per item No 211 above,but for split type AC 3.0 ton/4.0 Ton capacity, 425 Volts 3 phase all as specified and directed. 217 Supply and fix push tap CP brass, 15 mm suitable for water cooler of any capacity all as specified and directed. 218 Material and labour for repair of voltage stabilizer after removig the burnt out unserviceable winding cleaning the slots, insulate properly and rewindingtransformer including testing of capacity 5 KVA, single phase, 230 V AC, 50 Hz all as specified and directed. 219 All as per item No 218 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed 220 Material and labour for repair of voltage stabilizer by replacing time delay relay /main relay unit of voltage stabilizer with new of capacity 5 KVA, 4KVA including testing complete all as directed. 221 All as per item No 220 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed. 222 Supply and replace service valve for split type AC of 1/4 Size all as specified and as directed. 223 Supply and replace service valve for split type AC of1/2 Size all as specified and as directed. 224 Supply and replace service valve for split type AC of5/8 Size all as specified and as directed. 225 Supply & replace condenser unitfor split AC of the following type and any make / capacity all as specified and as directed: 226 1.5 Ton capacity 227 2.0Ton capacity 228 Supply & replace outer body kit for split type AC of following capacities complete with condensor coil and fan motor complete of existing make all as specified and directed. Note: Compressor, condensor coils and fan motorwill be measured and paid separately. 229 1.5 Ton capacity 230 2.0Ton capacity 231 Supply and replace copper pipe 1/4all as specified and as directed. 232 Supply and replace copper pipe 1/2all as specified and as directed. 233 Supply and replace copper pipe 3/4all as specified and as directed. 234 Supply and replace copper pip 5/8all as specified and as directed. 235 Supply and replace flair nut 1/4all as specified and as directed. 236 Supply and replace flair nut 1/2all as specified and as directed. 237 Supply & replace drain PVCpipe for split type AC any capacity all as directred. 238 Supply and replace PC Board of indoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed 239 Supply and replace PC Board of outdoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed 240 S & F Grill for enclosing the outer unut of air conditioners of any capacity 241 Supply & fix flexible PVC pipe for drinking purpose of any dia suitable for any type of water cooler 242 Supply & replace MS/GI bracket for fixing of outer unit of Air conditioners of capacity 1.5 ton/2.0 ton all as specified and as directed 243 Supply and replace Metal plug and socket with MCB 20 Amps and steel enclosureall as specified and as directed 244 Supply and replace MCB SP5 to 30 Amps 230 Vall as specified and as directed 245 M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FR grade with copper conductorconfirming to IS 694 drawn inconduit including provision of suitable dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed. 246 Ditto as per item ser No 245here in after but for4x6.0 sq. mm + 1x6.0 sq. mm earth wire All as specified 247 Supply and replace thermocool insulation for copper pipe for split type AC of any type and capacity.all as specified and as directed 248 Supply and replace unserviceable fan blade of outdoor unit fan motor of split type AC 1.0/1.5/2.0/ 3.0 ton capacity with new fan blade all as specified and directed. 249 Comprehensive Annual Maintenance Contract (AMC)of water cooler by OEM . Make :Cross field Water Purifiers Pvt Ltd (17 Qty) complete all as specified and as directed.Note : The work includes changing of filter element, PC board,UV lamp, UV choke, hose, angle cock tap including pipe connection etc as per site requirement and all as specified. 250 Supply and replace of all filter of water cooler / purifire CANTT RO or any type and capacity of existing make complete all as specified and as directed 251 Supply and installation of 3/4 PVC drain piping system for outdoor motor unit, including all necessary fittings and connections to ensure proper drainage of condensate water complete all as specified and as directed. 252 Repairs/ Replacement of internal electrification including fittings and fixtures of buildings at 42 WEUunder GE (AF) Tvm 253 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc all as directed. 254 M&L for point wiring complete with 1.5 Sqmmsingle core FRLSH PVC insulated sheathed cable 1100 V grade multi stranded copper conductor drawn through and including non metallic rigid PVC conduit and accessoriesconcealed in walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including2mmModular metal flush Box and suitable Modular white cover plate with frame andall as specified and directed. 255 One fan/light /bell point controlled by one switch/bell push 256 One switch socket outlet 5 Amps on independent board 257 One 3 pin socket outlet, 5 Amps on the same board with other swictches with cables 1.5 Sq mm size all as directed. 258 All as per Item No 257 here-in- before but with 2.5 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed. 259 Supply and fix in replacement switch piano flush button single pole oneway 6 amps all as directed. 260 Supply and fix in replacement socket flush type 2 in 1, 3 pin 6 amps. 261 Supply and fix switch socket combination 3 pin 5 Amps flush type in repairs. 262 Supply and fix switch socket combination 6A/16 A , 5 in 1 flush type , universal flush type. 263 Supply and fix in replacement ceiling rose surface bakelite with three terminals all as directed.Make- Anchor/Havells/Legrand. 264 Supply and fix bell push flush type 5 Amps 230V singlepole all as directed. Make- Anchor/Havells/Legrand. 265 Supply and Replaceelectric bell Ding Dong, AC 230 voltsall as specified. Make- Anchor/Havells/Legrand. 266 Supply and Replace buzzer, AC 230 voltsall as specified. Make- Anchor/Havells/Legrand. 267 S & F electronic type fan regulator rotary step 120/280 watt all as specified and directed. Make- Anchor/Havells/Legrand 268 Taking down unserviceable submain wiring and M&L for submain wiring in PVC conduit with two runs of 4 Sq mm and one run of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded drawn through and including 25 mm dia PVC rigid connduit includung accessories such as bends, supports etc all as specified 269 Taking down unserviceable MCB distribution board, S & F SPN 4 way of any size and capacity double door with suitable busbar including disconnecting from mains and making good the disturbed surfaces all as directed.Make- Anchor/Havells/Legrand. 270 All as per item No 269 here in before but SPN 8 way. Make- Havells/Legrand/ABB 271 All as per item No 269 here in before but SPN 12 way. Make- Havells/Legrand/ABB 272 Supply and fix in replacement sheet metal enclosure distribution board for fixing MCBs with double door, TPN 4 way, 415 volts with suitable bus bar complete all as directed. Make- Anchor/Havells/Legrand. 273 Disconnecting and removing the existing metal plug and socket and and provn ofmetal plug and socket single phase two pin and earth plug with MCB, SP 20 Amps and steel enclosure. Make- Anchor/Havells/Legrand. 274 Removing of exsitingCeiling fan 1200mm sweepfrom postion, painting with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, kept in safe custodyand refixing after completion of work to postion, alongwith required accessoriesin new postion as directed 275 All as per Item No.274 above but for exhaust fan 300mm sweep including replacing of rusted nut and bolts. 276 M & L for cutting & removing the burnt winding of ceiling fan of 1200mm sweep and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating and reassembling the spares complete all as specified. 277 All as per item No. 276 above but for exhaust fan 300mm sweep. 278 Supply and Replacecapacitor 2.5 mfd suitable for ceiling fanMake – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON 279 Supply and Replacecapacitor 4 mfd suitable for exhaust fan. Make – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON 280 Disconnecting and removing the old unserviceable light fitting box type 1 x 40W / 1 x 28 Watts T-5 fitting and supply and fix new energy efficentLED batten 1 x 20 watts 4 feet long CRCA body powder coated whitebatten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as directed. Make; Havells/Wipro/Crompton 281 Disconnecting and removing the old unserviceablelight fitting box type 1 x 20W / 1 x 14 Watts T-5 fitting and supply and fix new energy efficentLED batten 1 x 10watts 2 feet long powder coated white batten type all prewired including LED tube and connection with twin core flexible PVC 0.5 Sqmm complete all as directed. Make- Havells/Wipro/Crompton 282 Removing existing Unserviceable surface mounting light fittings CFL 36 watt typeand supply and fix surface mounting LED light fittings1 x 33 / 36 watts LED panel system efficiency 36 W LED 6500 K model suitable for armstrong/grid/POP false ceiling complete all as specified and directed. Make : Havells/Wipro/Crompton 283 Removing existing Unserviceable recess mounting light fittings CFL 36 watt typeand supply and fix recess mounting LEDlight fittings1 x 33 / 36 watts LED panel system efficiency 36 W LED 6500 K model suitable for fitting infalse ceiling complete all as specified and directed. Make : Havells/Wipro/Crompton 284 Supply and fix inreplacement 415V 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning MCB TPN40A- 100A 285 Supply and fix only the MCB/RCCB 240V,50Hz,AC with repturing capacity 10kA of the following capacities all as specified and as directed. Make-Havells/Legrand/ABB. 286 MCB SP 6A - 32A 287 RCCB Double pole, 30mA 25 A 288 SPN 32 AMP 289 Maint/ Repair of water supply distribution system repair of pump sets, shallow wells and allied works at 42 WEU at GE (AF) Tvm 290 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth forlaying UG cable/steel tubing etc and getting out in hard/dense soil complete all as specified and directed. 291 Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm thick with soil complete all as specified and directed. 292 Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 293 Taking up or down steel tubing and connections of size 25mm dia bore including cleaning for refixing or removal to store complete all as specified and directed.Note: Excavation and earth work shall be measured and paid seperately 294 All as per item No. 293 here in above but of size 50mm dia bore 295 Supply and laying and testing ofmedium grade galvanised iron steel tubing of size 25mm dia bore, ISI marked, including GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tees, checknuts, caps, plugsetc complete laid in trenches/floors etc complete all as specified and directed. Make : Jindal/Tata/Prakash 296 All as per item No. 295 here in above but of size 50mm dia bore 297 Taking up or down UPVC(Unplaticised PVC)pipe and connections of size 25mm dia bore including cleaning for refixing or removal to store complete all as specified and directed.Note :Excavation and earth work shall be measured and paid seperately 298 All as per item No. 297 here in above but of size 50mm dia bore 299 Supply and fix replacement 3-layer UPVC pipes of pressure rating 10 kgf/sqr cm having thermal stabilityincluding all UPVC plain and brass threaded polypropylene random fittings fixed for size 25mm dia bore complete to walls,ceillings or in floorscomplete all as specfied and directed 300 All as per item No. 299 here in above but of size 50mm dia bore 301 S & F in replacement of Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm diabore and conforming to IS 778 of 1984 complete all as specified and directed.Make : Leader/Kirloskar/Zoloto 302 All as per item No. 301 here in above but of size 50mm dia bore 303 S & F in replacement of gun metal non return valve of 50 mm dia bore, screwed complete all as specified and directed.Make:leader/ Kirloskar/ zoloto 304 S & F in replacement of CIfoot valveBall type flanged end of size 50mm dia bore, flanged/as per IS - 4038 with nuts, bolts and gaskets etc complete all as specified and directed. Make Normax,/Kirloskar/ Leader 305 S & F in replacementofDOL starter suitable for induction motor of current rating 2 to 6 A, 3 Phase 415 Volts, 50 Hz AC complete all as specified and directed.Make: L&T/ siemens/Schineder 306 Dismantling three phase 440 volts motors of 3 HP capacities, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc complete all as specified and directed. 307 M & L for cleaning Static water tank of 15000 ltr capacity by draining/ pumping out completely , cleaning with high pressure pump and pipe lines for removing scales, algae,silt accumulated at the bottom of the tank, flushing out completely and cleaningthe tank usingchlorine based disinfectans like sodium hypochlorite (liquid beach) or Hydrogen peroxide of not less than 10 KG using high pressure dosing pump and keep it for min 4 hours to the bacteria and painting the wall with food grade synthetic paint and keeping in UV light for minimum of 2 to 3 hrs, writing the date of cleaning and capacity on outside of sump in bold letters etc as per the existing colour and fontcomplete all as specified and directed.
Contract Date: Dec 02, 2025 Contract Value : 27.42 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
11.
Public Administrative Department #7660089 AOC
Qcbs Tender For High Performance Computing Hpc Facility Along With Accessories And Consumables Qcbs Tender For Design Supply Installation Testing And Commissioning Of High Performance Computing Hpc Facility With Sustained Performance High Performance Multi Node Computing Cluster With Hybrid Cpu Gpu Nodes , Design, Supply, Installation, Testing And Commisioning Of High Performance Of Computing (Hpc) Facility , Server (Master Nodes) - Processor: Make: Intel/Amd, Series: Platinum/Gold/Epyc (Latest Series), Number Of Processors: 2, No. Of Cores/Processor: 16, No Of Threads/Core: 2, Base Frequency: >= 2.9Ghz, Turbo Frequency: >= 3.50 Ghz, Cache: >= 24 Mb, Form Factor: Rack/Blade, Size: 2U, Support: Avx/Avx2; Motherboard, Chip-Set Compatible: Intel/Amd, Max Cpu Sockets: 2; Memory: Type: Ddr4 Rdimm Ecc, Single Memory Module: 16Gb, Speed: >=3200 Mt/S, Memory Size: 128Gb, Max Memory Support: > 512Gb (32Gb Module); Storage: Sas Ssd: 2 No’S, Sasssd Size: 800Gb, Sas Ssd Req: Os Partition, Sas Ssd Raid Level: Raid 1, Sata Ssd Usable Size: 5Tb, Min Sata Ssd Drives: >=5, Sata Ssd Raid Level: Raid 5; Raid Cards: Raid Level: 0,1,5,6,10,50,60, Ports/Lanes: >= 8, Cache: >= 8Gb Nv, Interface Support: Sas, Sata, Nvme; Interfaces & Ports: Total Network Cards: 2, Network Card1 Type: Ethernet, Network Card1 Speed: 1G And 10G Supported, Network Card1 Portsrequired: 4X1g And 10G Supported, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same, Network Card2 Type: Sfp28, Network Card2 Speed: 10G/25G, Network Transceivers: 25Gb Sfp28 Sr 100M Transceiver & Cables, Network Card2 Portsrequired: 2, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same; Operating System, Certifications/Compliance (Os): Rhel 7,8+, Ubuntu 20+, Oracle Linux 8,9+, Debian 11,12+, Windows, Certifications/Compliance (Virtualization/Cloud Platform): Vmware, Proxmox, Kvm, Citrix, Server Monitor (With Advanced License): Separate Monitoring Interface: Inbuilt Web-Based Secure Server Hardware Monitoring Alerting System. , Server (Compute Nodes)* - Processor, Make: Intel/Amd ,, , Series: Platinum/Gold/Epyc (Latest Series), , Number Of Processors: 4, , No. Of Cores/Processor: 18, , No Of Threads/Core: 2, , Base Frequency: >= 2.9Ghz, , Turbo Frequency: >= 3.50 Ghz, , Cache: >= 24 Mb, , Form Factor: Rack/Blade, , Size: 2U/4U, , Support: Avx/Avx2, Motherboard, Chip-Set Compatible: Intel/Amd, , Max Cpu Sockets: 4, Memory, Type: Ddr4 Rdimm Ecc, , Single Memory Module : 32Gb, , Speed: >=3200 Mt/S, , Memory Size: 512Gb, , Max Memory Support: > 1Tb (32Gb Module), Co-Processor / Gpu, Na: Na, Storage, Sas Ssd: 2 No’S, , Sasssd Size: 800Gb, , Sas Ssd Req: Os Partition, , Sas Ssd Raid Level: Raid 1, , Sata Ssd Usable Size: 5Tb, , Min Sata Ssd Drives: >=5, , Sata Ssd Raid Level: Raid 5, Raid Cards, Raid Level: 0,1,5,6,10,50,60, , Ports/Lanes: >= 8, , Cache: >= 8Gb Nv, , Interface Support: Sas, Sata,Nvme, Interfaces & Ports, Total Network Cards: 2, , Network Card1 Type: Ethernet, , Network Card1 Speed: 1G And 10G Supported, , Network Card1 Ports Required: 4X1g And 10G Supported, , Pxe Support: Yes, , Virtual Machine Device Queues (Vmdq): Yes, , Pci-Sig* Sr-Iov Capable: Yes, , Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same: Yes, , Network Card2 Type: Sfp28, , Network Card2 Speed: 10G/25G, , Network Transceivers: 25Gb Sfp28 Sr 100M Transceiver & Cables, , Network Card2 Ports Required: 2, , Pxe Support: Yes, , Virtual Machine Device Queues (Vmdq): Yes, , Pci-Sig* Sr-Iov Capable: Yes, , Server Network Ports Should Support Dpdk, And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same: Yes, Operating System, Certifications/Compliance (Os): Rhel 7,8+, Ubuntu 20+, Oracle Linux 8,9+, Debian 11,12+, Windows , , Certifications/Compliance (Virtualization/Cloud Platform): Vm Ware, Proxmox, Kvm, Citrix, Server Monitor (With Advanced License), Separate Monitoring Interface: Inbuilt Web Based Secure Server Hardware Monitoring Alerting System , Server (Compute Nodes - High Memory) - Processor: Make: Intel/Amd, Series: Platinum/Gold/Epyc (Latest Series), Number Of Processors: 4, No. Of Cores/Processor: 18, No Of Threads/Core: 2, Base Frequency: >= 2.9Ghz, Turbo Frequency: >= 3.50 Ghz, Cache: >= 24 Mb, Form Factor: Rack/Blade, Size: 2U/4U, Support: Avx/Avx2; Motherboard: Chip-Set Compatible: Intel/Amd, Max Cpu Sockets: 4; Memory: Type: Ddr4 Rdimm Ecc, Single Memory Module: 32Gb/64Gb, Speed: >=3200 Mt/S, Memory Size: 2Tb, Max Memory Support: >2Tb (32/64Gb Module); Storage: Sas Ssd: 2 No’S, Sasssd Size: 800Gb, Sas Ssd Req: Os Partition, Sas Ssd Raid Level: Raid 1, Sata Ssd Usable Size: 5Tb, Min Sata Ssd Drives: >=5, Sata Ssd Raid Level: Raid 5; Raid Cards: Raid Level: 0,1,5,6,10,50,60, Ports/Lanes: >= 8, Cache: >= 8Gb Nv, Interface Support: Sas, Sata, Nvme; Interfaces & Ports: Total Network Cards: 2, Network Card1 Type: Ethernet, Network Card1 Speed: 1G And 10G Supported, Network Card1 Portsrequired: 4X1g And 10G Supported, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same, Network Card2 Type: Sfp28, Network Card2 Speed: 10G/25G, Network Transceivers: 25Gb Sfp28 Sr 100M Transceiver & Cables, Network Card2 Portsrequired: 2, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same; Operating System, Certifications/Compliance (Os): Rhel 7,8+, Ubuntu 20+, Oracle Linux 8,9+, Debian 11,12+, Windows, Certifications/Compliance (Virtualization/Cloud Platform): Vm Ware, Proxmox, Kvm, Citrix; Server Monitor (With Advanced License): Separate Monitoring Interface: Inbuilt Web-Based Secure Server Hardware Monitoring Alerting System. , Server (Compute Nodes Gpu Cluster) - Processor: Make: Intel/Amd, Series: Platinum/Gold/Epyc (Latest Series), Number Of Processors: 2, No. Of Cores/Processor: 18, No Of Threads/Core: 2, Base Frequency: >= 2.9Ghz, Turbo Frequency: >= 3.50 Ghz, Cache: >= 24 Mb, Form Factor: Rack/Blade, Size: 2U/4U, Support: Avx/Avx2; Motherboard: Chip-Set Compatible: Intel/Amd, Max Cpu Sockets: 2; Memory: Type: Ddr4 Rdimm Ecc, Single Memory Module: 32Gb, Speed: >=3200 Mt/S, Memory Size: 512Gb, Max Memory Support: > 1Tb (32Gb Module); Gpu/Fpga/Acceleration Cards: Make: Nvidia, Series: H100 Nvl 94Gb, Number Of Gpu: 1, Number Of Cuda Cores: >16,896, Number Tensor Cores: >528, Memory: >=48Gb; Storage, Sas Ssd: 2 No’S, Sasssd Size: 800Gb, Sas Ssd Req: Os Partition, Sas Ssd Raid Level: Raid 1, Sata Ssd Usable Size: 5Tb, Min Sata Ssd Drives: >=5, Sata Ssd Raid Level: Raid 5; Raid Cards: Raid Level: 0,1,5,6,10,50,60, Ports/Lanes: >= 8, Cache: >= 8Gb Nv, Interface Support: Sas, Sata, Nvme; Interfaces & Ports: Total Network Cards: 2, Network Card1 Type: Ethernet, Network Card1 Speed: 1G And 10G Supported, Network Card1 Portsrequired: 4X1g And 10G Supported, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same, Network Card2 Type: Sfp28, Network Card2 Speed: 10G/25G, Network Transceivers: 25Gb Sfp28 Sr 100M Transceiver & Cables, Network Card2 Ports Required: 2, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk, And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same; Operating System: Certifications/Compliance (Os): Rhel 7,8+, Ubuntu 20+, Oracle Linux 8,9+, Debian 11,12+, Windows, Certifications/Compliance (Virtualization/Cloud Platform): Vm Ware, Proxmox, Kvm, Citrix; Server Monitor (With Advanced License): Separate Monitoring Interface: Inbuilt Web-Based Secure Server Hardware Monitoring Alerting System. , Server (Compute Nodes For Vm) - Processor, Make: Intel/Amd, Series: Platinum/Gold/Epyc (Latest Series), Number Of Processors: 2, No. Of Cores/Processor: 16, No Of Threads/Core: 2, Base Frequency: >= 2.9Ghz, Turbo Frequency: >= 3.50 Ghz, Cache: >= 24 Mb, Form Factor: Rack/Blade, Size: 2U, Support: Avx/Avx2; Motherboard: Chip-Set Compatible: Intel, Max Cpu Sockets: 2; Memory, Type: Ddr4 Rdimm Ecc, Single Memory Module: 32Gb, Speed: >=3200 Mt/S, Memory Size: 256Gb, Max Memory Support: > 1Tb (32Gb Module); Storage: Nvme Ssd: 2 No’S, Nvme Size: 800Gb, Nvme Ssd Req: Os Partition, Nvme Ssd Raid Level: Raid 1, Nvme Ssd Usable Size: 8-10Tb, Min Nvme Ssd Drives: >=10, Sata Ssd Raid Level: Raid 5; Raid Cards: Raid Level: 0,1,5,6,10,50,60, Ports/Lanes: >= 8, Cache: >= 8Gb Nv, Interface Support: Sas, Sata, Nvme; Interfaces & Ports: Total Network Cards: 2, Network Card1 Type: Ethernet, Network Card1 Speed: 1G And 10G Supported, Network Card1 Portsrequired: 4X1g And 10G Supported, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same, Network Card2 Type: Sfp28, Network Card2 Speed: 10G/25G, Network Transceivers: 25Gb Sfp28 Sr 100M Transceiver & Cables, Network Card2 Ports Required: 2, Pxe Support, Virtual Machine Device Queues (Vmdq), Pci-Sig* Sr-Iov Capable, Server Network Ports Should Support Dpdk And It Should Deliver Zero Packet Loss As Per Rfc 2544 And Deliver 100%-Line Rate For All The Packet Sizes Over 64 Bytes, Vendor Must Submit Latest Dpdk Test Report For The Same; Hba Card: Fc-Hba Card; Supported Fc-Hba Card For Tape Library Interface; Operating System: Certifications/Compliance (Os): Rhel 7,8+, Ubuntu 20+, Oracle Linux 8,9+, Debian 11,12+, Windows, Certifications/Compliance (Virtualization/Cloud Platform): Vm Ware, Proxmox, Kvm, Citrix; Server Monitor (With Advanced License): Separate Monitoring Interface: Inbuilt Web-Based Secure Server Hardware Monitoring Alerting System. , Tier1 Storage (500Tb Capacity) - Storage Quality Certification: The Storage Oem Should Be Established In The Gartner Or Any Other Equivalent Global Research Firm For The Last Five Years; Storage Controller: 1. The Storage System Offered Must Be A True Unified And Scale-Out System Offering Nas (File), San (Block) And Object Workloads. The Storage Supplied Should Be An Appliance With A Single Microcode Offering All Protocols And Should Not Be Based On Server-Based General Purpose File Systems Or Operating Systems Such As Linux, Windows Etc., 2. Storage System Must Be Offered In A No-Single-Point Of Failure Offering Up To Six 9S Of Availability With A Minimum Of 2 Nodes/Controllers And Scale-Out To A Minimum Of 12 Nodes/Controllers; Cache/Memory Support: 1. The System Should Be Offered With A Minimum 1.2 Tb Distributed/Global/Federated Dram Cache Across Dual Controllers. The Cache Should Be Scalable To 6 Tb In A Scale-Out Architecture With A Minimum 12 Controllers. The System Should Offer The Capability To Protect The Write Cache In Case Of A Controller Failure. Also, A Failure Of A Controller Should Not Lead To Write-Through Mode For Cache; Drive Support: The System Must Support Nvme Ssds Each Of 100Gbe Interface Speed To Meet The Capacity And Performance Requirements For The Applications. The System Must Support A Minimum Of 240 Disks For Scalability Purposes; Disk Drive Protection: The Proposed System Should Offer Minimum Raid 6/Dual Drive Failure Protection, However For High-Density Drives It Should Also Support Triple Drive Failure Protection For Better Resiliency And Performance; Capacity: 1. The System Should Be Configured With 500Tb Usable Capacity Using Nvme Ssd Drives With Raid 6/ Dual Drive Failure Protection; Performance: The Storage Should Be Able To Deliver A Minimum Of 345,000 Iops And 10Gbps (Gigabyte) With R/W 80/20, Sequential 32K Block; Protocols: The Storage Should Be Configured Natively With Fc, Nvme-Of, Nvme/Tcp, Iscsi, Nfs (Nfsv3, Nfsv4, Nfsv4.1 Supporting Rfc5661), Cifs/Smb Protocols For Use With Different Applications. In Addition To The Above, Object (S3 Compatible) Protocol Should Also Be Supported Either Natively Or Through Any Additional Appliance; Front-End And Backend Connectivity, The Proposed Storage System Should Have A Minimum 4 X100gbe Back-End Ports And 8 X 10Gbe Iscsi And 8 X 32 Gb Fc Front-End Ports Available Across Dual Controllers; Investment Protection: 1. The Storage Offered Should Be A True Scale-Out System That Allows The Intermixing Of Controllers Across Generations Within The Same System, The System Should Also Support The Intermixing Of All-Flash And Hybrid Arrays Is The Same Cluster And Be Scalable To A Minimum Of 12 Controllers For Maximum Investment Protection, 2. The Proposed System Should Offer The Capability To Tier The Data To Either On-Prem Or Cloud Object Storage. The System Should Be Configured With Any Software Capability Or License For On-Prem Tiering To Object Storage From Day One; Storage General Features: 1. Ability To Expand Luns/Volumes On The Storage Online And Instantly, 2. Redundant Hot-Swappable Components Like Controllers, Disks, Power Supplies, Fans Etc. And Allow Re-Usage Of Disk Shelves With Higher Models Of The Same Product Line, 3. The Proposed System Should Offer Up To 20Pbs Capacity Scalable Within A Single Namespace, 4. The Proposed Storage Should Enable And Integrate With Server Virtualization Technologies Such As Vmware Vsphere. The Proposed Storage Must Support Vasa 3.0 And Above, Vmware Vvol Feature And The Feasibility Of Creating More Than 1000 Vvols. The Proposed Array Should Be Able To Present Both The Vvol Storage Pool And Traditional Lun’S, 5. The Storage System Should Be Capable Of Providing Multi-Pathing Software With Failover And Load-Balancing Functionality, 6. The Proposed Storage Should Provide Both In-Line And Post-Process Efficiency Features Such As Compression, De-Duplication And Compactation, 7. The Proposed Storage Should Be Able To Provide Secure Multi-Tenancy For Air Gap Security And Isolation From Other Workloads; Data Protection: 1. The Proposed System/Solution Should Offer Incremental Replication Capabilities In Both Fan-Out And Cascading Topologies. The Wan Replication Should Be Secured By End-To-End Encryption And Bandwidth Optimization Supported Natively. All The Necessary Licenses Should Be Quoted From Day 1; 2. The Storage Array Should Be Offered With Synchronous, Asynchronous Replication Features & Zero Data Loss Protection Between The Dc, Dr And Near Dr, 3. The Offered System Should Ensure A Unified Architecture Flexibility For Replication Both On-Prem & To The Cloud Natively Without The Use Of Any Third-Party Hardware Or Software Solutions. The Replication Should Support End-To-End Encryption And Bandwidth Optimization, 4. Proposed Storage Should Offer Capabilities To Create Backup Copies Across Sites And Also Allow Replication Of Data Across Backup Targets. Any License Required Should Be Configured; Security And Encryption, 1. The Proposed Storage Array Must Support Data At Rest Encryption For File Shares Including Both Cifs And Nfs, Managed By An On-Board Key Manager Or External Key Manager Offering Industry-Standard Certification/Compliance By Using A Cryptographic Security Module Supporting Fips 140-2 Level Encryption. For Multi-Tenant Configuration, Individual Tenants Keys Should Be Managed By The Offered Storage, 2. The Storage System Should Offer High-Performance Compliance Solutions In Accordance With Various Industry Standards To Meet Regulations Such As Securities And Exchange Commission (Sec) 17A-4, Hipaa, Financial Industry Regulatory Authority (Finra), Commodity Futures Trading Commission (Cftc), And General Data Protection Regulation (Gdpr), 3. Storage Management Software Should Support Mfa To Ensure Secure Access To Management Software. The Storage Array Should Support Sha-2 Level Security For Managing User Credentials, 4. The Storage Should Be Configured To Comply With Sec Rule 17A-4 For File Systems.Also, The Offered Storage Should Ensure That No One Including The Administrator Should Can Delete The Data Post Worm Enabled; Management, 1. The Proposed Storage System Should Have Native Gui To Monitor & Perform Operations On Data Protection Jobs, 2. The Storage Management Software Should Offer Operational Simplicity And Rich Data Management Functionalities For Unified Storage. It Should Provide A Single Dashboard To Monitor The Health, Availability, Capacity Usage, Performance, And Data Protection Status Of Various Platforms Along With Resource Planning, 3. The Management Tool Should Display System Alerts And Notifications For Proactive Management On The Dashboard For Users To Quickly Access Them And It Should Provide Information About Support Cases Raised On The Cluster, 4. The Offered System Should Support Ransomware And Insider Threat Detection To Protect Data With Early Detection And Actionable Intelligence On Ransomware And Other Malware Incursions. It Should Detect Malicious Activity And Protect The Data By Automatically Taking A Snapshot; Rack Mountable: The Storage Should Be Supplied With A Rack Mount Kit. All The Necessary Patch Cords (Ethernet And Fiber) Shall Be Provided And Installed By The Vendor; Warranty & Amc: The Hardware And Software Quoted Should Have 5 Years Of Support Along With Upgrades And Updates; Storage Type: Nas; Number Of Nodes: 4; Drive Type: Nvme, Qlc; End-To-End Nvme; Total Usable Capacity (Tb): 500 Tib; Systems Disk Shelfs Connectivity (Gbps): 100Gb (Controllers To Disk Shelf); Systems Backend Network Connectivity: 25Gb (Node To Node); Scalable Nas (Up To Max), 9Pb; System Cpu Proposed: >=48 Cores; System Cpu Per Node, 12 Cores; System Memory Proposed, >=256 Gb; System Memory Per Node, >=64 Gb; Nvdimm/Nvram, >=8 Gb Per Node; Total Nvdimm/Nvram, >=32 Gb; Network Configuration Proposed, 8 X 25G Sfp28 & 16 X 25G Sfp28; Cloud Tiering Or Fabric Pool,; Compression,; Deduplication,; Thin Provisioning,; Data Access Protocols, Fc, Iscsi, Nvme/Fc, Nvme/Tcp, Fcoe, Nfs, Smb, Amazon S3; Dual Network Active-Active Switch For Customer Connection, 2X24port Sfp28 Switch With Minimum Of 4X40g/100G Qsfp28 Port For Uplink; Tiering Support, Should Support Auto Tiering And Tiering Policies. Software’S For The Tiering Management Has To Be Included. , Tier 2 Storage (500 Tb Capacity) - Storage Quality Certification: The Storage Oem Should Be Established In The Gartner Or Any Other Equivalent Global Research Firm For The Last Five Years. , 2, Storage Controller: 1. The Storage System Offered Must Be A True Unified And Scale-Out System Offering Nas (File), San (Block) And Object Workloads. The Storage Supplied Should Be An Appliance With A Single Microcode Offering All Protocols And Should Not Be Based On Server Based General Purpose Filesystems Or Operating Systems Such As Linux, Windows Etc, : 2. Storage System Must Be Offered In A No-Single-Point Of Failure Offering Upto Six 9S Of Availability With Minimum 2 Nodes/Controllers And Scale-Out To Minimum 12 Nodes/Controllers, : 1. The System Should Be Offered With Minimum 256Gb Distributed/Global/Federated Dram Cache Across Dual Controllers. The Cache Should Be Scalable To 1536 Gb In A Scale-Out Architecture With Minimum 12 Controllers. System Should Offer Capability To Protect The Write Cache In Case Of A Controller Failure. Also, A Failure Of Controller Should Not Lead To Write-Through Mode For Cache, 4, Drive Support: The System Must Support Nvme Ssds Each Of 100Gbe Interface Speed To Meet The Capacity And Performance Requirements For The Applications. The System Must Support A Minimum Of 96 Disks For Scalability Purpose, 5, Disk Drive Protection: The Proposed System Should Offer Minimum Dual Drive Failure Protection, However For High Density Drives It Should Also Support Triple Drive Failure Protection For Better Resiliency And Performance, 6, Capacity: 1. The System Should Be Configured With 500Tb Capacity Using Nvme Ssd Drives With Dual Drive Failure Protection, 7, Performance: The Storage Should Be Able To Deliver Minimum 150,000 Iops And 4.5 Gbps (Gigabyte) With R/W 80/20, Sequential 32K Block, 8, Protocols: The Storage Should Be Configured Natively With Fc, Nvme-Of, Nvme/Tcp, Iscsi, Nfs (Nfsv3, Nfsv4, Nfsv4.1 Supporting Rfc5661), Cifs/Smb Protocols For Use With Different Applications. In Addition To The Above, Object (S3 Compatible) Protocol Should Also Be Supported Either Natively Or Through Any Additional Appliance, 9, Front-End And Backend Connectivity: The Proposed Storage System Should Have Minimum 4 X100gbe Back-End Ports And 8 X 10Gbe Iscsi And 8 X 32 Gb Fc Front End Ports Available Across Dual Controllers, 10, Investment Protection: 1. The Storage Offered Should Be A True Scale-Out System That Allows Intermixing Of Controllers Across Generations Within The Same System And Scalable To A Minimum Of 12 Controllers For Maximum Investment Protection. , : 2. The Proposed System Should Offer Capability To Tier The Data To Either On-Prem Or Cloud Object Storage. System Should Be Configured With Any Software Capability Or License For On-Prem Tiering To Object Storage From Day-One, 11, Storage General Features: 1. Ability To Expand Luns/Volumes On The Storage Online And Instantly, : 2. Redundant Hot Swappable Components Like Controllers, Disks, Power Supplies, Fans Etc. And Allow Re-Usage Of Disk Shelves With Higher Models Of The Same Product Line, : 3. The Proposed System Should Offer Upto 20Pbs Capacity Scalable Within A Single Namespace, : 4. The Proposed Storage Should Enable And Integrate With Server Virtualization Technologies Such As Vmware Vsphere. The Proposed Storage Must Support Vasa 3.0 And Above, Vmware Vvol Feature And Feasibility To Create More Than 1000 Vvols. The Proposed Array Should Be Able To Present Both Vvol Storage Pool And Traditional Lun’S, : 5. The Storage System Should Be Capable Of Providing Multi-Pathing Software With Failover And Load Balancing Functionality, : 6. The Proposed Storage Should Provide Both In-Line And Post Process Efficiency Features Such As Compression, De-Duplication And Compression, : 7. The Proposed Storage Should Be Able To Provide Secure Multi Tenancy For Air Gap Security And Isolation From Other Workloads, 12, Data Protection: 1.The Proposed System/Solution Should Offer Incremental Replication Capabilities In Both Fan-Out And Cascading Topologies. The Wan Replication Should Be Secured By End-To-End Encryption And Bandwidth Optmization Supported Natively. All The Necessary Licenses Should Be Quoted From Day 1, : 2. The Storage Array Should Be Offered With Synchronous, Asynchronous Replication Feature & Zero Data Loss Protection Between The Dc, Dr And Near Dr, : 3. The Offered System Should Ensure A Unified Architecture Flexibility For Replication Both On-Prem & To The Cloud Natively Without The Use Of Any Third-Party Hardware Or Software Solutions. The Replication Should Support End-To-End Encryption And Bandwidth Optimization, : 4. Proposed Storage Should Offer Capabilities To Create Backup Copies Across Sites And Allow Replication Of Data Across Backup Targets. Any License Required Should Be Configured, 13, Security And Encryption: 1. The Proposed Storage Array Must Support Data At Rest Encryption For File Shares Including Both Cifs And Nfs, Managed By On-Board Key Manager Or External Key Manager Offering Industry Standard Certification/Compliance By Using A Cryptographic Security Module Supporting Fips 140-2 Level Encryption. For Multi-Tenant Configuration, Individual Tenants Keys Should Be Managed By The Offered Storage, : 2. The Storage System Should Offer High-Performance Compliance Solution In Accordance To Various Industry Standards To Meet Regulations Such As Securities And Exchange Commission (Sec) 17A-4, Hipaa, Financial Industry Regulatory Authority (Finra), Commodity Futures Trading Commission (Cftc), And General Data Protection Regulation (Gdpr), : 3. Storage Management Software Should Support Mfa To Ensure Secure Access Of Management Software. The Storage Array Should Support Sha-2 Level Security For Managing User Credentials, : 4. The Storage Should Be Configured To Comply With Sec Rule 17A-4 For Filesystems.Also, The Offered Storage Should Ensure That No One Including Administrator Should Be Able To Delete The Data Post Worm Enabled, 14, Management: 1. The Proposed Storage System Should Have Native Gui To Monitor & Perform Operations On Data Protection Jobs, : 2. The Storage Management Software Should Offer Operational Simplicity And Rich Data Management Functionalities For Unified Storage. It Should Provide A Single Dashboard To Monitor Health, Availability, Capacity Usage, Performance, And Data Protection Status Of Various Platforms Along With Resource Planning, : 3. The Management Tool Should Display System Alerts And Notifications For Proactive Management On The Dashboard For Users To Quickly Access Them And It Should Provide Information About Support Cases Raised On The Cluster, : 4. The Offered System Should Support Ransomware And Insider Threat Detection To Protect Data With Early Detection And Actionable Intelligence On Ransomware And Other Malware Incursions. It Should Detect Malicious Activity And Protect The Data By Automatically Taking A Snapshot, 15, Rack Mountable: The Storage Should Be Supplied With Rack Mount Kit. All The Necessary Patch Cords (Ethernet And Fiber) Shall Be Provided And Installed By The Vendor, 16, Warranty & Amc: The Hardware And Software Quoted Should Have 5 Years Support Along With Upgrade And Updates, 17, Tiering Support: Should Support Auto Tiering And Tiering Policies. Software’S For The Tiering Management Must Be Included , Tier 3 Storage (500 Tb Capacity) - 1, Storage Quality Certification: The Storage Oem Should Be Established In The Gartner Leader Quadrant , 2, Storage Controller: 1.The Storage System Should A Unified System Supporting All Block, File And Object Protocols Cluster In Active-Active Configuration, : 2. Storage System Must Be Offered In A No-Single-Point Of Failure Offering Upto Six 9S Of Availability With Minimum 2 Nodes/Controllers And Scale-Out To Minimum 12 Nodes/Controllers, 3, Cache Required: 1. The Unified System Should Have Minimum 128 Gb Data Cache Post Protection Overheads Across Supplied Controllers With An Ability To Protect Data On Cache If There Is A Controller Failure Or Power Outage. Cache Should Be Protected For Writes Either Through A Battery Backup Or By Destaging To Flash/Disk, : 2. The System Should Be Configured With Minimum 2Tb Of Ssd/Flash/Nvme In Addition To The Above And Same Should Be Scalable To 12Tb, 4, Drive Support: The Unified System Must Support Intermixing Of Ssd, Sas And Sata Drives To Meet The Capacity And Performance Requirements Of The Applications. The System Must Support A Minimum Of 140 Disks In A Dual Controller Architecture And Maximum Of 570 Disks In A Scale-Out-Architecture, 5, Protocols: The Storage Should A True Unified Storage Configured With Iscsi, Fc, Fcoe, Nfs (Nfsv3,Nfsv4, Nfsv4.1) Smb(,Smb2 & Smb3) ,S3 And Pnfsprotocols For Use With Different Applications And Should Support The Maximum Capacity Offered By The Storage System. Any Hardware/Software Required For This Functionality Shall Be Supplied Along With It In No Single Point Of Failure Mode, 6, Raid Configuration: Should Support Raid 6/Dual Parity & Triple Parity, 7, High Availability: The Unified Storage System Must Be Configured To Continuously Serve Data In Event Of Any Controller Failure. In Addition To This, It Must Also Be Possible To Withstand Failure Of Any 2 Or 3 Disks Per Raid-Group Of Size Not More Than 28 Disks.In Event, Architecture Uses A Single Pool Instead Of Multiple Raid Groups, System Should Be Resilient Against Failure Of Three Drives For Every 28 Drives Used In The Pool, 9, Storage Capacity: Storage Must Supply With 500 Tb Usable Capacity Nl-Sas Disk With Raid6/Dp/ Triple Parity With Spare Drive At 30 Drives One Spare Drive Need To Be Populated, 10, Performance: The Storage Should Be Able To Deliver 700 Mbps (Megabyte)/22,000 Iops With 80/20 R/W Sequential 32K Block, 11, Front-End And Backend Connectivity: The Proposed Storage System Should Have Minimum 4X12gb Sas Ports And 4X10gbe Fiber And 4 X 32Gbps Fc Front End Ports Available Across Dual Controllers, 12, Rack Mountable: The Unified Storage Should Be Supplied With Rack Mount Kit. All The Necessary Patch Cords (Ethernet And Fiber) Shall Be Provided, 13, Storage Scalability And Upgradability: 1. The Unified Proposed System Should Be Field Upgradeable To A Higher Model Through Data-In-Place Upgrades, : 2. The Unified Storage Should Be A True Scale-Out Architecture Allowing Mixing Of Controller/Nodes Within Same Product Line With Higher Configurations, : 3. Unified Storage System Should Allow Re-Usage Of Disk Shelves With Higher Models Of The Same Product Line, 14, Storage Functionality : The Unified Storage Shall Have The Ability To Expand Luns/Volumes On The Storage Online And Instantly, : The Unified Storage Shall Have The Ability To Create Logical Volumes Without Physical Capacity Being Available Or In Other Words System Should Allow Over-Provisioning Of The Capacity. The License Required For The Same Shall Be Supplied For The Maximum Supported Capacity Of The Offered Storage Model, : The Unified Storage Should Be Configured With Quality-Of-Service Feature For Iops/Throughput For Both Block And File, : The Unified Storage Shall Support Logical Partitioning Of Controllers In Future Such That Each Partition Appears As A Separate Virtual Storage In Itself For Both Block And File, : The Storage Should Support Data Tiering With Real-Time Movement Of Hot Data To High Performing Drives. It Should Offer The Capability To Move Data Between One Tier Of Drives To Another Tier Of Drives, : The Proposed Unified Storage System Should Be Configured To Provide Data Protection Against Two Simultaneous Drive Failures, : The Required Number Hard Disks For Parity & Spares, Should Be Provided Exclusively Of The Usable Capacity Mentioned. , : Unified System Should Have Redundant Hot Swappable Components Like Controllers, Disks, Power Supplies, Fans Etc, 15, Point-In-Times Images: The Unified Storage Should Have The Requisite Licenses To Create Point-In-Time Snapshots. The Storage Should Support Minimum 250 Snapshots Per Volume/Lun. The License Proposed Should Be For The Complete Supported Capacity Of The Unified System For Both Block And File, : The Unified System Should Support Instant Creation Of Clones Of Active Data, With Near Zero Performance Impact For Both Block And File, 16, Encryption For Data At Rest: The Proposed Storage Array Must Support Data At Rest Encryption Offering Industry Standard Certification/Compliance. The Storage Array May Implement Data At Rest Encryption Using Self-Encrypting Drives Or Controller-Based Functionality There By Not Impacting Performance, 17, Management: Single Management, Easy To Use Gui Based And Web Enabled Administration Interface For Configuration, Storage Management And Performance Analysis Tools For Both Block And File, 18, Remote Support & Diagnostics: Storage Management Should Support Call Home Facility With Web-Based Self-Service Portal Providing An Integrated, Efficient Monitoring And Reporting Capability And Supporting Data Collection. Management Software Should Provide Features Like; : 1. Automated Call Home Feature, : 2. Nonintrusive Alerting, : 3. Performance And Capacity Reports, : 4. Ongoing Health Check Analysis, Os Support: Support For Industry-Leading Operating System Platforms Including: Linux, Microsoft Windows, Hp-Ux, Sun Solaris, Ibm-Aix, Etc, : Any Multipathing Software Required For The Solution Must Be Supplied For Unlimited Host Connectivity, 19, De-Duplication, Compression And Compaction: Proposed Unified Storage Should Support Iline As Well As Post Process Block Level Data De-Duplication, Compression And Compaction For All Kinds Of Data (Structured & Unstructured) On Both Block And File, 20, Vmware Integration:The Proposed Storage Should Enable And Integrate With Server Virtualization Technologies Such As Vmware Vsphere. The Proposed Storage Must Support Vasa 3.0 And Above, Vmware Vvol Feature And Feasibility To Create More Than 1000 Vvols. The Proposed Array Should Be Able To Present Both Vvol Storage Pool And Traditional Lun’S, 21, Multi-Pathing: The Storage System Should Be Capable Of Providing Multi-Pathing Software With Failover And Load Balancing Functionality, 22, Certifications: The Storage System Should Offer High-Performance Compliance Solution In Accordance To Various Industry Standards To Meet Regulations Such As Securities And Exchange Commission (Sec) 17A-4, Hipaa, Financial Industry Regulatory Authority (Finra), Commodity Futures Trading Commission (Cftc), And General Data Protection Regulation (Gdpr), 23, Warranty & Sla: The Hardware Quoted Should Have 5 Years Onsite Warranty And Support, 24, Tiering Support: Should Support Auto Tiering And Tiering Policies. Software’S For The Tiering Management Must Be Included , Next-Generation Firewall Specifications - 1, The Firewall Must Be Appliance Based, Rack Mountable And It Should Be Having Internal Redundant Power Supply From Day One:, 2, The Proposed Firewall Vendor Should Be In The Leaders/ Challenger In Quadrant Of Gartner Magic Quadrant For Enterprise Network Firewall.; 3, The Proposed Ngfw Must Have Build In Gui And Cli To Make On The Go Changes To Firewall Policies Without Any Dependency To Management And Troubleshoot Any Issue Related To Network Outage.; 4, Ngfw Must Support Secure Sd - Wan Feature Along With Advance Routing Protocols Such As Bgp ; 5, Sd-Wan Must Be Able To Link And Failover Between Various Connections Such As Internet, Mpls, Leash Line And Even Routed Based Vpn Interfaces.; 6, Build-In Sdwan Must Be Able To Do Load Balancing Of Various Links Based On Source Address, User Group, Protocol And/Or Applications ; 7, Sla For Sdwan Must Be Defined Based On Packet Loss Or Latency Or Jitter. Even Combination Of All 3 Option Must Be Possible ; 8, Central Management Solution For The Next Generation Firewall Must Be Able To Manage All The Sdwan Link Centrally And Should Give Clear Dashboard Showing Which Links Are Down And Which Are Up. This Helps The Noc To Take Action Accordingly; 9, Ngfw Must Support Multicast Routing As Well As Firewalling ; 10, The Proposed Solution Should Also Support Policy Routing. Policy Routing Should Work Along With Sd-Wan And Isp Load-Balancing.; 11, The Proposed Solution Must Also Support Identity-Based Routing Option Allowing Traffic To Be Forced Out Of Specific Internet/Mpls Gateway Based On Authentication Rather Than Ip Address; 12, The Proposed System Should Have Integrated Traffic Shaping Functionality This Feature Should Have Option To Be Configured On Same Firewall Policy Along With Option To Configure It Separately If Required.; 13, Build-In Gui On The Ngfw Should Have Option To Display Logical Topology Of The Network The Ngfw Is Protecting. The Display Should Also Be Able To Give Security Recommendation For The Ngfw.; 14, Device Should Support Static Routing, Rip, Ospf,Bgp, Is-Is, Ripng, Ospfv3 And Bgp4+, Performance Parameters; 1, The Solution Should Support A Minimum Of At Least 12 Gbps Ips Throughput & Minimum 11 Gbps Ngfw Throughput On Real-World / Enterprise Mix Traffic Test Condition; 2, The Solution Should Support Minimum 10 Gbps Threat Protection Throughput On Real-World / Enterprise Mix Traffic Test Condition; 3, Should Support 20 Gbps Ipsec Vpn Throughput And 1500 Tunnels; 4, The Firewall Must Support At Least 6,000,000 Concurrent Connections And 500,000 New Sessions Per Second; 5, The Platform Must Be Having Minimum Of 10 Interfaces With Auto Sensing 10/100/1000 Capability, 6 Gigabit Sfp Ports And 8 10-Gbe Sfp+ Interfaces From Day One, Firewall Features; 1, Firewall Policy Should Be Single Policy Where All The Features Get Applied Such As Ips, Application Control, Url Filtering, Antivirus, Ssl Inspection, Logging And Even Nat ; 2, Firewall Must Support Zoning Option Along With User Based Authentication. It Must Have Automatic Option To Group All The Same Zone Policy ; 3, There Must Be Option To Configure The Said Firewall Policy From Gui Of The Ngfw Appliance Without Requiring Any Management Solution. This Is In The Case Of Emergency Where Management Solution Is No Available And Policy Needs To Be Changed.; 4, Firewall Must Support Nat46, Nat66 And Nat64 Along With Policy For Such Nat Along With Option To Configure Dns64.; 5, Firewall Must Support Nat Policy For Multicast Traffic For Both Ipv4 And Ipv6; 6, Firewall Must Support Option To Configure Fqdn Server Rather Then Ip Address In Case Server Have Dynamic Ip Address Or Site Have Multiple Ip Addresses For Single Domain.; 7, There Must Be Option To Even Configure Wildcard Fqdn; 8, Firewall Should Allow Policy Based On Port Or Service To Protect Attack At L3 Not Just Application Based Policy Which Might Be Vulnerable To L3 Attacks.; 9, Firewall Must Support Geo-Based Ip Address Blocking Option.; 10, Dns Translation Option Must Be Available In Firewall To Change Only The Specific Dns Reply From Public To Private Ip. This Is Required For Allowing User To Access Local Resources Using Private Ip Rather Than There Public Ip Address; 11, Build-In Gui/Cli Must Support Option To Configure Firewall Policy Which Allow Packet Capture For Troubleshooting Purposes; 12, The Security Appliance Should Be Having Configurable Option To Quarantine Attack Generating Source Address, Virtualization; 1, The Proposed Solution Should Support Virtualization (Virtual Firewall, Security Zones And Vlan). Minimum 5 Virtual Firewall License Should Be Provided.; 2, Virtualization Must Be For Every Feature Which Are Ips, Application Control, Antivirus/Anti-Malware, Url Filtering, Ssl Inspection, Ssl Vpn, Ipsec Vpn, Traffic Shaping And User Authentication.; 3, Enabling Virtualization Shouldnt Require Any Kind Of Downtime Or Reboot. It Must Be Done Seamless Even If The Ngfw Is Live In The Network.; 4, When Creating Virtualized Ngfw It Should Give Mode Option To Configure Each Virtualized System Such As First System Can Work In Nat/Route Mode And Second System Can Work In Transparent Mode.; 5, Each Virtualized Ngfw System Must Have Option To Configure Various Parameter To Limit The Resources Utilization Such As Number Of Session, Etc, Vpn Features; 1, Ngfw Must Have Build In Support Ipsec Vpn And Ssl Vpn. There Shouldnt Be Any User License Restriction; 2, Ipsec Vpn Must Include Gateway To Gateway And Gateway To Client Vpn. In Case Of Gateway To Client The Administrator Must Have Option To Assign Private Ip Address To Remote User Without Requiring Any Additional License; 3, Route Based Ipsec Vpn Must Be Supported Along With Sd-Wan In Case Of Two Or More Isps.; 4, Ipsec Vpn Must Include Gateway To Gateway And Gateway To Client Vpn. In Case Of Gateway To Client The Administrator Must Have Option To Assign Private Ip Address To Remote User Without Requiring Any Additional License; 5, Ipsec Vpn Must Support Sha-1 And Sha-2 ( Sha 256, 386 And 512) Along With Dh Group 2,5,14,15,16,17,18,19,20,21,27,28,29,30 And 31.; 6, Ssl Vpn Must Support High Level Algorithm Along With Tls V1.2 ; 7, Ssl Vpn Must Not Have Any User License And Should Have Option To Integrate With Local Ad Or Radius Server ; 8, Both Vpn Must Support 2-Factor Authentication With Option To Have Locally Imported Tokens On The Nfgw Appliance Itself, If Required, Intrusion Prevention System; 1, The Ips Detection Methodologies Shall Consist Of:, A) Signature Based Detection Using Real Time Updated Database, B) Anomaly Based Detection That Is Based On Thresholds; 2, The Ips System Shall Have At Least 7,000 Signatures; 3, Ips Signatures Can Be Updated In Three Different Ways: Manually, Via Pull Technology Or Push Technology. Administrator Can Schedule To Check For New Updates Or If The Device Has A Public Ip Address, Updates Can Be Pushed To The Device Each Time An Update Is Available; 4, In Event If Ips Should Cease To Function, It Will Fail Open By Default And Is Configurable. This Means That Crucial Network Traffic Will Not Be Blocked, And The Firewall Will Continue To Operate While The Problem Is Resolved; 5, Ips Solution Should Have Capability To Protect Against Denial Of Service (Dos) And Ddos Attacks. Should Have Flexibility To Configure Ipv4 And Ipv6 Rate Based Dos Protection With Threshold Settings Against Tcp Syn Flood, Tcp/Udp/ Port Scan, Icmp Sweep, Tcp/Udp/ Sctp/Icmp Session Flooding. Threshold Settings Must Be Customizable For Different Sources, Destinations & Services; 6, Ips Signatures Should Have A Configurable Action Like Terminate A Tcp Session By Issuing Tcp Reset Packets To Each End Of The Connection, Or Silently Drop Traffic In Addition To Sending A Alert And Logging The Incident; 7, Signatures Should A Severity Level Defined To It So That It Helps The Administrator To Understand And Decide Which Signatures To Enable For What Traffic (E.G. For Severity Level:High Medium Low) , Antivirus; 1, Firewall Should Have Integrated Antivirus Solution; 2, The Proposed System Should Be Able To Block, Allow Or Monitor Only Using Av Signatures And File Blocking Based On Per Firewall Policy Based Or Based On Firewall Authenticated User Groups With Configurable Selection Of The Following Services:, A) Http, Https, B)Smtp, Smtps, C) Pop3, Pop3s, D) Imap, Imaps, E) Ftp, Ftps; 3, The Proposed System Should Be Able To Block Or Allow Oversize File Based On Configurable Thresholds For Each Protocol Types And Per Firewall Policy, Web Content Filtering; 1,The Proposed System Should Have Integrated Web Content Filtering Solution Without External Solution, Devices Or Hardware Modules.; 2, The Proposed Solution Should Be Able To Enable Or Disable Web Filtering Per Firewall Policy Or Based On Firewall Authenticated User Groups For Both Http And Https Traffic.; 3, The Proposed System Shall Provide Web Content Filtering Features:, A) Which Blocks Web Plug-Ins Such As Activex, Java Applet, And Cookies, B) Shall Include Web Url Block, C) Shall Include Score-Based Web Keyword Block, D) Shall Include Web Exempt List; 4, The Proposed System Shall Be Able To Queries A Real Time Database Of Over Millions+ Rated Websites Categorized Into 75+ Unique Content Categories.; 5, Update Of Local Database Based On Malicious Category Discovered By Local Sandboxing Solution From Same Vendor, Application Control ; 1, The Proposed System Shall Have The Ability To Detect, Log And Take Action Against Network Traffic Based On Over 4000 Application Signatures; 2, The Application Signatures Shall Be Manual Or Automatically Updated; 3, The Administrator Shall Be Able To Define Application Control List Based On Selectable Application Group And/Or List And Its Corresponding Actions; 4, Application Control And Url Filtering Must Work Independent Of Each Other, High Availability; 1, The Proposed System Shall Have Built-In High Availability (Ha) Features Without Extra Cost/License.; 2, The Device Shall Support Stateful Session Maintenance In The Event Of A Fail-Over To A Standby Unit.; 3, High Availability Configurations Should Support Active/Active Or Active/ Passive , Warranty; 1, Warranty And Support For 5 Years; 2, Support Includes Latest Patch Updates, Oem Should Be Having The Following Certifications/Ratings; 1, Firewall Module Should Be Eal 4 Certified, Centralized Logging & Reporting Solution; 1, The Solution Should Deliver Complete Security Oversight With Granular Graphical Reporting; 2, The Solution Should Provide Centralized Security Event Analysis, Forensic Research, Reporting, Content Archiving, Data Mining And Malicious File Quarantining.; 3, The Solution Should Provide Detailed Data Capture For Forensic Purposes To Comply With Policies Regarding Privacy And Disclosure Of Information Security Breaches.; 4, The Solution Should Analyze User Traffic Behaviour And Identify Compromised Users/Computers; 5, The Solution Should Provide Network Event Correlation To Allow Administrators To Quickly Identify And React To Network Security Threats Across The Network.; 6, The Solution Should Provide Streamlined Graphical Network-Wide Reporting Of Events, Activities And Trends Occurring On Utm / Ngfw; 7, The Solution Should Provide Centralized Logging Of Multiple Record Types Including Traffic Activity, System Events, Viruses, Attacks, Web Filtering Events, And Messaging Activity/Data; 8, The Solution Be Able To Provide Real-Time And Historical Logs With Filtering And Search Capabilities; 9, The Solution Should Be Able To Displays A Map Of The World That Shows The Top Traffic Destination Country By Colour; 10, The Solution Should Provide Predefined Templates For Building / Generating Reports; 11, The Solution Should Be Able To Collect Logs From Multiple Devices; 12, The Solution Should Support Out-Of-The-Box Playbook Templates For Enabling Soc Analysts To Quickly Customize The Use Case, Including Playbooks For Investigation Of Infections, Compromised Hosts, Critical Incidents, Data Enrichment For Viewing Assets And Identity Blocking Of Malware, C&C Ips; 13, The Solution Should Be Able To Support Threshold Values To Generate Alerts.; 14, The Solution Should Be Able To Send Alert Emails; 15, The Solution Should Be Able To Manually Generate The Report Or Schedule The Same; 16, The Solution Should Be Able To Generate Report Based On User Names; 17, The Solution Should Be Able To Process 50 Gb Logs Per Day; 18, The Solution Should Be Having Minimum 8 Tb Log Storage Capacity After Configuring Raid For Data Protection. ; 19, Logging & Reporting Architecture Shall Be Hardware Or Software-Based Appliance/ Vm Based Solution And The Hardware For The Solution Must Be Supplied By The Bidder. , 10G/25G Switch - Device Should Have Non-Blocking Architecture With Wire Speed L2 And L3 Forwarding, :, Device Should Have 48 X 1/10/25G Sfp28 Ports Supporting Rs-Fec And Fc-Fec As Per Ieee 802.3By Compliance, ; Device Should Have 8 X 40/100G Qsfp28 Ports With Support Breakout To Provide Additional 16 Number Of 10/25/50G Interfaces, ; Device Should Have Total Throughput Of 4Tbps And Latency Packet Forwarding Less Than 850 Nanoseconds, ; Device Should Support Copper Base-T (1G & 10G) Connectivity Over Cat6 Cable And 1G, Dual Rate 10G/25G Sfp+ Fiber Connectivity Over Mm And Sm Cable, ; Device Should Support Upto 250K Mac Address, ; Device Should Support Upto 256K Ipv4 Prefix Routes, ; Device Should Support Unified Forwarding Table (Uft) Feature To Flexibility Allocate Forwarding Table Resources To Address Different Type Of Use Cases, ; Device Should Have Max Power Draw Of Upto 315W, ; Shall Support Active/Active Layer2/Layer3 Multipathing Redundancy With Multi-Chassis Link Aggregation (Mlag) Or Equivalent Technology While Keeping Control Plane And Management Plane Distributed, ; L2 Features, ; Device Should Support 4K Vlans, 9216 Jumbo Frames, ; Device Should Support Mst, Per-Vlan, Rstp, Bpdu Guard, Loop Guard, ; Device Should Support Port Acl With L2, L3 And L4 Parameters, ; Device Support Lldp And Lacp To Bundle Links And Detect Miscabling Issues, ; Device Should Support Ieee 802.1D, 802.1Q, Q-In-Q, 802.1W, 802.1S And 802.1X, , ; L3 Features, ; Device Should Support Routing Protocols: Ospfv2 With Multiple Instances, Ospfv3, Bgp, Mp-Bgp, Is-Is, And Ripv2, ; Device Should Support Graceful Restart For Bgp, Ospf V2 And V3 And Isis, ; Device Should Support Bfd Inclusive Of Bfd For Lag Links, Bfd For V4 And V6 Vrf, Multi-Hop Bfd And Bfd On Ip Unnumbered Interfaces, ; Device Should Support Policy Based Routing (Pbr) For Ipv4 And Ipv6, Vrrp V4 And V6, Resilient Ecmp, Unicast Reverse Path Forwarding (Urpf), And Inter-Vrf Route Leaking, ; Device Should Support Accumulated Igp Metric (Aigp), Bgp Monitoring Protocol (Bmp) And Bgp Prefix Origin Validation With Resource Public Key Infrastructure (Rpki), ; Device Should Support Vxlan+Evpn Leaf-Spine Overlay Technology Supporting Type-1 To Type-8 Routes, ; Device Should Have Support For Symmetric And Asymmetric Irb With Evpn With Distributed Gateway Functionality, ; Device Should Support Ipv4 And Ipv6 Clients In Evpn Based Overlay Network, ; Device Should Support Active-Active Evpn Multi-Homing, ;Device Should Support Dynamic Nat Options Like Many-To-Many Nat And Many-To-One Nat (Pat) At Line Rate With No Additional Latency, ; Device Should Support Igmp V2/V3,Pim-Sm / Pim-Ssm, Anycast Rp (Rfc 4610), Vrf Support For Ip Multicast, Multicast Source Discovery Protocol (Msdp)And Ip Multicast Multipath, ; High Availability, ; Device Should Support Hitless Upgrade & Reloads In Mlag/Vpc Setup And Standalone (Non-Stack) Setup, Without Adversely Affecting The Forwarding Plane With Sub Second Data Outage During Upgrade, ; Device Should Support Maintenance Mode/ Graceful Insertion And Removal (Gir) To Isolate Device From The Network In Order To Perform Debugging Or An Upgrade While Gracefully Steering Traffic To Peer Nodes, ; Device Should 1+1 Redundant & Hot-Swappable Fans With Support For Both Front-To-Rear And Rear-To-Front Airflow Options, ; Device Should Support 1+1 Redundant & Hot-Swappable Power With Support For Both Ac And Dc Power Supply Options, ; Device Should Support Low-Memory Mode Wherein During Out Of Memory Condition The Device Kills Non-Essential Agents Until The System Recovers The Necessary Amount Of Memory, ; Security, ; Should Support Storm Control And Control Plane Protection (Copp), ; Should Support Port Acl With L2, L3 And L4 Parameters, ; Should Support Limiting Number Of Mac Address On A Link, ; Device Should Support Security-Group Based Segmentation Of Hosts Independent Of The Network Constructs Like Vlan, Vrf And Nvo, ; Device Should Protect Against Arp And Dhcp Spoofing By Ensuring That A Port Will Only Permit Ip And Arp Packets With Ip Source Addresses That Have Been Authorized, ; Device Should Support Ieee 802.1X Authentication Framework, Mac Authentication, Dynamic Vlan Assignment, Dynamic Acl Assignment And Coa, ; Device Should Support Multicast Accounting To Aaa Servers, ; Management, ; Device Should Support Secure Zero Touch Provisioning With Options To Provision Certificates Artifacts On The Device When It Boots, ; Should Support Tracking Changes In Mac Table, Arp, Ipv6 Neighbor Table And Ipv4, V6 Route Table For Troubleshooting Purpose, ; Should Support Real Time State Streaming For Advance Monitoring From Day 1, ; Should Support Telnet, Industry Standard Hierarchical Cli, Sshv2, Https, Scp, Sftp, Cli Task Scheduler And Configuration Session, ; Should Support Ntp And Ieee 1588 Ptp (Transparent Clock And Boundary Clock), ; Should Support Snmp V1/2/3 And Openconfig Model Over Grpc/Netconf, ; Device Should Support Digital Optical Monitoring (Dom), ; Device Should Support Real Time Data Collection With Sflow/Netflow, ; Automation & Visibility, ; The Device Should Monitor Output Queue Lengths For All Device Interfaces And Log And Stream Events Related To Congestion, ; The Device Should Automatically Mirror Traffic Queued In Event Of Congestion/Latency Or Micro Burst And Send Mirrored Traffic To Cpu, Directly Connected Server And Remote Server As Per Usecase, ; Device Should Support Multi Oem Hypervisor Environment And Should Be Able To Sense Movement Of Vm And Configure Network Automatically, ; Device Should Support Capturing Of Information Around Dropped Packet Events With Associated Reasons And Details Which Can Be Streamed Out Using A Open Communication Protocol Like Grpc Or Equivalent, ; The Device Should Have Openstack Neutron For Ml2 Integration With Evpn Vxlan Control Plane Support, ; Device Should Support Advanced Mirroring Features: Mirror To Cpu, Acl Filters And Truncation On Mirror Sessions, And Tunneling Of Mirror Packets To Remote Servers, ; Should Support Measure The Two-Way Metrics Such As Delay, Jitter, Packet Loss Rate Between Two Network Elements Using Two-Way Active Measurement Protocol (Twamp) As Per Rfc 5357, ; Should Have Programmability And Automation Support With On Board Python, Bash And Docker Containers, ; Qos, ; Should Support 8 Queues Per Port, ; Should Support Priority Queue, ; Should Support Weighted Fair Queue Or Weighted Round Robin Or Equivalent, ; Should Support Wred And Dscp For Cpu Generated Traffic, ; Should Support Acl Based Classification For Qos, ; Should Support Ieee 802.1Qaz Dcbx (Data Center Bridge Exchange), 802.1Qbb Pfc (Priority-Based Flow Control) And Explicit Congestion Notification (Ecn), ; Should Support Rate Limiting Function Like Policing And Shaping, ; Others, ; Should Be Certified For Ndcpp Common Criteria, ; Should Have Ipv6 Ready Logo Certification, ; Should Be 19 Rack Mountable With 4-Post Rail Mount Kit Provided For Easy Installtion, ; Hardware Replacement Warranty And Tac Support Should Be Directly From The Oem. Oem Email-Id And India Contact Support No. To Be Provided, ; Transceivers Should Be From Same Oem As Of Device, ; Warranty, ; Warranty And Support For 5 Years , 1/10G Switch - 1/10G 10Gbase-T/Multi-Gigabit Ports Switch, :, Port Count: 24/48, ; Uplink: Min 4 X 25Gb Sfp28 Uplinks, ; Efficiency: Support Roce, ; Features; ; Speed: 100M/1000M/2.5G/5G/10Gbase-T, ; 1+1 Hot-Swappable Power Supplies And 2+1 Smart Fans, ; Support Qos, Ospf, Dhcp, Bgp, Vrrp, Qinq, ; Support Acl, Radius, Tacacs+, Dhcp Snooping, Etc. For Security, ; Warranty, ; Warranty And Support For 5 Years. , System Integration - Installation, Configuration, Testing And Commissioning Of Hpc Facility.
Contract Date: Jul 29, 2025 Contract Value : 143.00 Crore
Government Departments No of Bidders 7
12.
Defence #7636241 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. E signifies this fact only. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. (HIGH SIDE (MACHINES))(Outdoor unit) 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 Design, Supply, Installation, Testing and Commissioning of Normal Type Floor Mounted Packaged AC Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by Engineer - in - charge, of following capacitiesNote: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. LOW SIDE (MACHINES))(Indoor unit) 24 a) 22 TR Inverter Package AC Units 25 b) 16.5 TR Inverter Package AC Unit 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 160 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No(iii) Aluminium Bus bar TPN - 200 amps- 1setOUTGOING(i) MCCB 3 Pole 125 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release- 01 No.(iii) MCB TPN 32 Amp -02 Nos(iv) 80 HP S/D STARTER- 01 Nos(v) DOL STARTER 7.5 HP- 01 Nos(vi) Motor Protection Relay32-88 amps- 1 no. (vii) Motor Protection Relay2-5.5 amps- 1 no. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 2 No. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply, Installation,Testing & commissioning of Water Mist High pressure stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 78 Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete. 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Single mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. A single top rail mounted on the racking system shall also support it.General technical parameters of stacker crane:Technical parameters/Type- Single Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system :- Two aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelSingle mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system duyring the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASRS system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASRS system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integratedMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advance Inventory Management System with computer hardware with compatible inventory software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height : 6400 (±100) mm(ii) System Width : 3150 (±100) mm(iii) System Depth : 2300 (±100) mm(iv) System Base : 7.24 Sq.Mtr(v) Tray Int. Size: 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 KgTechnical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(x) Storage surface area per system - 39.2 sq mtr(xi) Door - Automatic(xii) Power consumption - 3.7 KW(xiii) Power supply - 440V, 50/60 Hz, 3 Phase(xiv) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xv) Chain - Diamond makeor equivalent(xvi) Bearing - SKF/NTN make or equivalent(xvii) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: The system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system. 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS,100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 16 KA- 02 No. Ics =100% Icu -2 nos.(b) MCB, TPN 40 Amp, 415 Volt, C Curve - 02 Nos.(c) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(d ) Digital ammeter - 2nos.(e) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 M 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c ) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(e) Fly wheel housing and fly wheel to suit alternator.(f) Engine bearing mechanism in fly wheel housing.(g) Shut off coil with safeties for LLOP/HWT/over speed.(h) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Motor driven priming pump.(m) Battery charging alternator.(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) Interconnecting copper cabling of adequate capacity batteries control.(r ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(s) Self starter 12 volts DC.(t) Electric operated electronic governor.(u) Fuel injection pump.(v) No of cylinders - 12 No VEE(w) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(w) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(y) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(z) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) Isolator panel with 250 amp MCCB(ab) Auto logic panel for automatic stat(b) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(iv) Bottom gland plate for incoming and outgoing cables.(v) Circuit diagram plate.Note :- DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Package AC Bulk Store & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the MES AGE E/M store complete all as specified & directed.(b) The Energy Meter to be capable of running in both prepaid and postpaid mode.(c) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 155 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 Testing of piles (Initial load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed
Contract Date: Jul 23, 2025 Contract Value : 57.42 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
13.
Defence #7544282 AOC
Tender For Provision Of Solar Plant At Af Station Tambaram; 1 SCHEDULE A PART - I (E/M Works)Detailed engineering, design including feasibility survey, supply, installation and testing on completion for ground mounted solar power plant using PV SYS and PV SOL or equivalent software, site survey, design etc. and getting the design vetted from any one of the MNRE approved agencies and submission to accepting officer for approval, Manufacturing, supplying, erecting, installing, testing and commissioning of grid connected floor mounted Solar PV Plant of total 500 KWp capacity at conditions prevalent at AFS Tambaram area with fixed structure on Turnkey basis, and performance guarantee basis including complete connected suitable foundation, civil and other complete structural worksas per OEM design and specification comprising of following sub-components/sub-systems and meeting the specifications as given hereinafter and in Particular specification as measured and paid separately.(Make in India) 2 The rate quoted shall be deemed to be included for the following as per OEM design and specifications :-Supply and erection of Solar Photovoltaic modules as per item No 01 latest edition of IEC PV module qualification test or equivalent BIS standards Poly-crystalline silicon solar cell Modules IEC 61215/IS14286. In addition, the modules must confirm to IEC 61730 Par-1- requirements for construction & Part-2-requirment for testing, for safety qualification or equivalent IS SPV Panel not less than 540 Wp including Terminal Box IP 65, bypass Diode, necessary size cable of required length with connectors. (tenderer to submit warranty for Modules-25 years) (Make in India)The total solar PV array capacity should not be less than allocated capacity (KWp) and should comprise of Mono Crystalline Silicon Solar Cell Modules of minimum 540 Wp and above wattage. Module capacity less than minimum 540wpshall not be accepted. (c)Protective devices against surges at the PV module shall be provide Low voltage drop bypass diodes shall be provided. (d) PV modules must be tested and approved by one of the IEC authorized test centers. (e) The module frame shall be made of corrosion resistant materials, preferably having anodized aluminium. Supply and erection of GroundMounting structure made of hot top dip galvanised steel with minimum galvanization thickness of 120 microns or Aluminium alloy and suitable for SPV module specified here-in-before, including bolts,nuts,fastners,panel mounting clamps /aluminium alloy mounting arrangements suitablewith M15 PCC(1:2:4) type B1 using 20 mm graded stone aggregate as per MNRE standards complete withstand 150KM wind speed and as directed.Solar on grid/grid tie Inverters of 125 KWp capacities as per MNRE Standards, outdoor type 3 phase of suitable capacities to achieve optimum efficiency. Provision of Array Junction box, with SPD combiner box as suitable for item no 01 complete all asspecified and directed for 125KWpDC Power interfacing Panel/Distribution boxes outdoor type with minimum thee incoming with synchronizing facility including necessary suitable capacity MCBs,Surge Arrestors, fuse boxes, necessary earthing ,testing and commissioning. Note: Panel Board shall also suitable to distribute auxiliary power to loads like UPS,street light, module cleaning system, etc for 125KWpPVC insulated suitable size of un armoured electric power cable with stranded copper conductor of necessary size & rating as per design including necessary cable tray and lugs complete all as specified and as directed.Note: 1. The scope shall also cover design, supply, erection, testing & commissioning of LT and 11 KV Transmission Line and associate 11 KV Bay Extension at Substation. The maximum capacity for inter connection with the grid at a specific voltage level shall be as per the Distribution Code/Supply Code of the state and amended from time to time. 3 (a) Pre-commissioning & Commissioning of all supplied Equipments and test running of Grid Connect Solar Power Plant as well as load trails at site . (c) Plants earthing & earthing for all equipments as directed shall generally be carried out in accordance with the requirements of IE Rules /CEA guidelines and IS: 3043. (b) Provision for Grid Islanding : In the event of a power failure on the electric grid, it is required that any independent power producing inverters attached to the grid turn off in a short period of time. This prevents the DC-to-AC inverters from continuing to feed power into small section of the grid, known as Islands . Powered Islands present a risk to workers who may expect the area to be unpowered, and they may also damage grid-tied equipment . The PV system shall be equipped with Islanding protection. In addition to disconnection from the grid (due to Islanding protection ) disconnection due to under and over voltage conditions shall also be provided. A manual disconnect 4-pole isolation switch beside automatic disconnection to grid would have to be provided at utility end to isolate the grid connection by the utility personnel to carry out any maintenance. the switch shall be locked by the utility personnel.(c) Any other items not specifically mentioned in the BOQ but which are required for erection, testing and commissioning and satisfactory operation of the solar power plant are deemed to be included in the scope. 4 Note:- (i) Pre despatch inspection shall be carried out by the authorised rep of Accepting officer before final dispatch. If any deviation is found from Schedule A specifications shall be rejected. (ii) All Modules shall be delivered at site once the mounting structure are erected and tested.(iii) Cost of miscellaneous component such as termination kits lugs, shine boards, conduits, MC4 for connectors Adopter box and other connected accessories etc shall be deemed to be included in the cost of Modules. 5 Standby supply shall be provided by contractor at no cost at the time of synchronizing with existing power supply system.Final approval (Technical feasibility report) shall be obtained from TNEB before starting work on ground.Any other component as required for efficient function of system shall be deemed to be included in the above quoted rates by the Contractor. 6 a). The materials used for structures shall be Hot dip Galvanized Mild Steel conformed to IS 2062:1992.b). The Bolts, Nuts, fasteners, and clamps used for panel mounting shall be of Stainless-Steel SS Grade.c). Additional Structures/Frames for required for the installation of modules if any need to be provided by the Contractor and cost of same is deemed to be included in the rate quoted by the Contractor.d). The structures shall be designed to allow easy replacement of any module, repairing and cleaning of any module.e). The structure shall be designed to withstand operating environmental conditions for a period of minimum 25 years. And shall be free from corrosion while installation.f) Minimum distance between the lower level of PV Module and the ground shall be 0.5m from the ground level.g) The structures should be suitably loaded with reinforced concrete blocks of appropriate weight made out of M25 concrete mixture.h) Photovoltaic must be mounted on a stable, durable structure that can support the array and withstand wind, rain, and other adverse conditions. The modules will be fixed on structures with fixed arrangement.i) 100% indigenous company. 7 Note :- (1) Contractor should visit the site before quoting the tender.(2) Suitability for Grid Connected System.(3) PV Modules & Solar Cells shall be made in India andmakes and manufacture by India Only. The contractor shall submit all required documents. The panel should be of latest edition. (4) Power Warranty - 10 year warranty on 90% of the design output and 25 years warranty on 80% of the design output as per MNRE ALMM registered. (5) TNEB registration fees, all the fees related to commissioning should be borne by the Contractor and there are deemed included in the rate quoted by the Contractor.(6) Work shall be executed as per TNEB & CEI norms.(7) All materials makes shall be approved as per MNRE.(8) Contractor Should have valid TEDA Empanelment Certificate. 8 (9) Liaisoning with TNEB authority for obtaining any relevant documents/approved of installation solar power plant to Grid from TNEB for smooth functioning shall be contractor responsibility and cost in this regard is deemed to be included in the rate quoted by the Contractor.(10) Feasibility clearance from state electricity board: Rate quoted by bidder is inclusive charges for feasibility clearance and Liaison work regarding the plant from starting to commissioning with TNEB will be done by the contractor and plant will be taken over after it is fully functional including Installation of Energy Reading meter and certified BY TNEB.(11) Standby supply shall be provided by contractor without any extra cost to department at the time of Synchronizing with existing 11 KV system.(12) Technical feasibility report shall be obtained from TNEB before starting work in ground.(13) Capacity of Inverter shall be as per design criteria and approved by Garrison engineer.(14) String Inverters only to be use for this project.(15) Solar meter and Bi-directional meter : Supply HT net meter / Bi-directional meter and solar meter to deposit to TNEB for testing and calibration thereafter taken back to site for installation. Contractor will not be claim extra cost from department for carried out of above said process. (16) SPV panels and on grid inverter should be in same OEM.(17) The Bidder shall carefully design and accommodate requisite numbers of the modules to get the design output as per topography. (18) The rate quoted by the bidder for Solar power plant and mounting structure (Serial item No.1) is inclusive of all provisions mentioned in Serial item No. 1.01 to 1.07. 9 Material and labour for Power monitoring system using 802.11n interface for harvesting from solar energy shall be connected into on-grid (grid-tie) inverters. The logger devices will also have GPRS communication for monitoring the same as requiredIntegration of all equipments and components including Laisoning work for Solar Netmeter from State Electricity Board for obtaining Netmeter including cost of the net metering and allied expenses including charges for permission to grid connection from state electricity board. 10 Material and labour for Lightning arrestor with necessary arrangement along with suitable EMC electrode erection by 1mt earth evacuation.Note: Lightning protection shall be provided as per the requirement of IS:2309 for PV modules. There shall be required number of suitable lightning arrestors in the array field. Lightning protection to be provide with required number of earthing as specified and directed. 11 Supply, Install, Testing and commissioning of outdoor type cubicle main control panel board self supporting totally enclosed factory fabricated, made out of 3 mm thick CRCA sheet steel with projected slope roof for rain water protection, dust and vermin proof, hinged front opening double door shutters with neoprene rubber gasket, powder coated including danger plate, earth bar-02 Nos, ventilation louvers, bottom detachable gland plate complete cubicle panel board suitable for 3 phase 4 wire,415 volts 50 Hz and 50mm x 50mm x 6mm angle iron base frame, with locking arrangement, including provision of suitable size PCC pedestal for mounting of panel board with required earthing and including the following Switch gear and necessary internal wiring and connections from the bus bar to switch gear, cable gland, necessary earthing complete all as specified:-(i) Copper bus strip TPN of suitable capacity placed on porcelain insulators, colour coded PVC sleeves for three phases and neutral-01 Set (ii) MCCB FP 400 Amps 415 V 36 KA adjustable type-03 No (iii) ACB 1000 Amps 415V-01 (iv) LED Phase Indication Lamp-03 Nos (R,Y,B) (v) Volt Meter digital type-01 No(vi) Amp Meter digital type with 3xCT-01 No 12 Material and labour for supply, install, Testing and Commissioning of Standalone ICOG outdoor metal clad Air Insulated Switchgear suitable SCADA Compatible rating 11 KV 3 Phase 50 cycles 630 Amps , 250 MVA 26.3 KA for 3sec type with copper bus bars/ jumpers with horizontal draw out type vaccum circuit breaker with motor and manual operated spring charge stored energy mechanism complete in and including necessary PCC Platform as per manufacture recommendation with following components.(i) ICOG Panel shall be made of CRCA powder coated steel sheet, dust and vermin proof, locking arrangement, totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with Copper bus bars, back entry type complete VCB panel confirming to IEC 62271-200 standards and connections with the following protective and including necessary PCC platform as required. control devices as specified below, Vacuum interrupters of the circuit breakers shall not be openly exposed design and shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the VI used in the breaker. The Circuit Breaker shall be suitable for E2, M2 duty. The circuit breaker should have valid type tests to support the afore-mentioned duty class. Tripping and/or release coils shall be continuous rated to ensure longer life. Internal spring charging handle to be provided in the VCB. The ICOG in and including following items:- 13 (a) Current Transformers 26.3 KA/ 1 sec, Epoxy cast resin type single phase CTs dual ratio i.e 200-100/1-1 A or as per site requirement as specified and directed by Department, CORE 1, CL 1.0, 15 VA Core 2-CL 5P10, 15 VA-03 Nos.(b) Single phase 11 KV Cast resin potential transformer (Draw out type) 11 KV/Route 3/110V/Route 3-core 1: 50VA CL1.0-03 No, MCB with add on contact for PT Secondary-02 No(c) Breaker discrepancy switch (TNC)-01 No, Emergency push button-01 No, L/R Switch-01 No, LED indication lamps-01 Set, 8 window alarm annunciator with RS 485 PORT-01 No, Bell/hooter-01 No MCB for Panel AC-01 No,MCB for Panel DC-01 No, MCB for spring charging motor-01 No, Anicondensation space heater/thermostat-01 No, 3 pin socket+switch-01 No, Test/Service limit switch for VCB-01 No, Surge Arrester-03 No Power pack-01 No.(d) Microprocessor controlled numeric relay with RS-485 port comprising of three over current, one earth protection relay with high set for both phases & earth and with fault memory, universal auxiliary supply-1 No.(e) Master Trip Relay(f) Trip Circuit Supervision relay-2 Nos(g) Digital Multifunction meter withRs-485 port with class 1.0. 14 Supply and installation of Step up transformer 0.433 KV/11 KV, copper woud,outdoor type 3 phase of capacity 630KVA including both LT/HT side closed compartment 4 wire LT side , 50 cycles per second, oil immersed, naturally cooled, off load tap changers and each with standard fittings/fixtures, cable box at HT/LT side complete including first fill of transformer oil to appropriate level, temp gauge, breather tank, cooling coil, LT side cable box to be fitted with suitable size of cable gland complete as per IS 1180 including necessary PCC platform for installation of transformer including testing commissioning as directed all as specified and as directed. 15 Supply, laying in trenches, or fixed on wall in position and testing XLPE insulated screened PVC bedded, armoured, electric power cables(Heavy duty) with aluminium conductor, 11000 volts grade (HT) earthed of cross sectional area 95 sqmm 3 core conforming to IS-7098(Part-II) with latest amendments complete all as specified and as directed Note :- (i) Excavation filling, Removal, Sand/riddle earth, Brick, GI Tubing shall be measured and paid separately under relevant items. 16 Earthing complete in positions with GI earth plate electrode of size 600m x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5mtr below ground connected to GI earth strip 32x6mm by means of GI bolts and nuts,checknuts, washers and GI earth strip protected by GI pipe light grade 40 mm bore upto 7.5 mtr and connecting to VCBs/transformers etc as per site requirement including necessary excavation, earth work in any type of soil PCC M-10 type C-1 earth chamber, 50mm thick RCC M-20 Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No. 3 of MES Schedule Part 1 complete all as specified and as directedNote:(i) Quoted rate deemed to include necessary earth work PCC chamber RCC cover reinforcement removal of surplus soil, site clearance etc.(ii) Earthing as mentioned in this item shall be operated for equipments other than solar power plant, Earthing required for solar PV panels, inverters and other solar power plant equipment are included in the rate quoted for item No.1. 17 Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and as directed. 18 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified and as directed. 19 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed. 20 Excavation in trenches not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out in hard/dense soil complete all as specified and as directed. 21 Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning. 22 Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. 23 Supplying and laying reinforced precast concrete cable cover, classHV,Type 2, flat, size 450mm180mm x 40mm complete all as specified and as directed. 24 Supplying and laying reinforced precast concrete cable cover, class LVType 2, flat, size 300mm x 180mm x 40mm complete all as specified and as directed. 25 Material and labour for galvanised iron strip 32 x 6mm buried in ground or fixed on pole with all accessories all as specified and as directed. 26 Material and labour for boring of holes under road, pavement, hard standing bytrenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. 27 Supply and lay GI tubing Light grade of size 80 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and as directed. 28 Supply and lay GI tubing Light grade of size 100 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and as directed. 29 Schedule A Part - IIPeriodical check/ services after successful completion work and during Defect liability period of two years. Cleaning of solar panels, Periodical checks and maintenance as recommended by the OEM including pruning of trees, clearing vegetation and ensuring the serviceability of the plant, Solar Panels, Inverters, Transformers, HT/LT Electrical panels etc including submitting monthly power generation report to the department, all during whole defect liability period of Two years from the date of completion of the work.Note : - (i) Cost of spare parts required for ensuring the serviceability of the plant during defect liability period of Two years from date of completion of the work is deemed to be included in the rate quoted for schedule A part-I Item No 1. Therefore it shall be considered that cost of spare parts is not included in this item being guarantee duration for defect liability period, hence rate shall quoted accordingly(ii) Periodical maintenance shall only be carried out by the authorsied representative of the original equipment manufacturer(OEM) of the plant.(iii) Electricity and water for maintenance of the plant will be supplied by the department free of cost at one location shown on site by the Engr-in-Charge.(iv) Keeping up of the maintenance record and the parameters of Solar PV power plant including ED/ MES shut down details shall be maintained by the contractor as directed by the Engineer-in-Charge. Any defects / short comings noticed shall be intimated to the department immediately 30 Schedule A Part - IIIComprehensive Maintenance of 0.5 MW Solar Power Supply project for First year after successful completion of Defect liability period (i.e 1st year after completion of Phase II). Comprehensive Maintenance of 0.5MW solar power plant complete system including maintain the SPV System, transformers, Invertors, HT/LT panels etc for first year after completion of defect liability period.Note:(i) Comprehensive Annual Maintenance contract (AMC) under which the Contractor shall maintain the SPV power generation plant (which would cover all items supplied by him under this Contract)(ii). Spare parts required for operation/maintenance of Solar PV Power plant during the currency of AMC period shall be included in the rate of this item. 31 (iii). Periodical maintenance as OEM recommendation on all parameters for SPV plant operation and diagnosis, routine checking and cleaning of solar panels, preventive maintenance as required for smooth and trouble-free operation of the SPV system (which would cover all items supplied by him under provision Contract ) shall be carried out by the Contractor during the service contract period. The Contractor shall attend to calls of breakdown as and when required.(iv) The Contractor shall ensure generation of power to give output as per plant installed capacity, failing penal charges equal to two times the energy charges paid to state Electricity board for the same will be imposed. (v) To take care of house keeping and maintain cleanliness of area upto 5m all around installations and PV module strings shall be kept dust free absolutely neat and clean.(vi) To maintain the installations provided under this contract as per IE rules/standard Engineering practice.(vii) Periodical maintenance shall only be carried out by the authorised representative of the original equipment manufacturer(OEM) of the plant.(viii) Electricity and water for maintenance of the plant will be supplied by the department free of cost.(ix) Cleaning of installation including pruning of trees etc, around the installation shall be carried out complete all as specified and as directed. (x) Keeping up of the maintenance record and the parameters of Solar PV power plant including ED/ MES shut down details shall be maintained by the contractor as directed by the Engineer-in-Charge. Any defects / short comings noticed shall be intimated to the department immediately. 32 All as per Item No. 22 here in before but for Second year after successful completion of Phase -II 33 All as per Item No. 22 here in before but for Third year after successful completion of Phase - II 34 Schedule A Part - IVPeriodical check/ services after successful completion work and after defect liability period of two years and three year maintenance. (i.e. 6TH YEAR from the date of completion of Phase - I) which comprises the following:-(a) Maintenance and operation of 500KW solar power plant including Supervising by Engineer / Skilled labour (b) Periodical checks and maintenance as recommended by the OEM, Solar Panels, Inverters, Transformers, HT/LT Electrical panels etc including submitting monthly power generation report to the department all as directed.(c) No of shifts : One shift per day i.e. One skilled labour for one shift. (Shift timing 09.00 Hrs to 17.00 Hrs) 35 All as per Item No. 25 here in before but for seventh year from the date of completion of Phase - I 36 All as per Item No. 25 here in before but for eigth year from the date of completion of Phase - I 37 All as per Item No. 25 here in before but for ninth year from the date of completion of Phase - I 38 All as per Item No. 25 here in before but for tenth year from the date of completion of Phase - I 39 Maintenance and operation of 500KW solar power plant during sixth year after completion of Phase - I for the following works:-Cleaning of solar Panel, Periodical checks and maintenance as recommended by the OEM including pruning of trees, clearing vegetation and ensuring the serviceability of the plant, Solar Panels, Inverters, Transformers, HT/LT Electrical panels etc including submitting monthly power generation report to the department all as per directed.No of shifts : Two shifts per day No of labours: One un-skilled labour for Two shifts. (Shift timing 06.00 Hrs to 14.00 Hrs, 14.00 Hrs to 22.00 Hrs) 40 All as per Item No. 30 here in before but for seventh year from the date of completion of Phase - I 41 All as per Item No. 30 here in before but for eighth year from the date of completion of Phase - I 42 All as per Item No. 30 here in before but for ninth year from the date of completion of Phase - I 43 All as per Item No. 30 here in before but for tenth year from the date of completion of Phase - I 44 Note for item 25 to 34 : - (i) Cost of spare parts required for ensuring the serviceability of the plant after defect liability period of Two years from date of completion of the work is deemed to be included in the rate quoted for schedule A part-IV Item No 25 to 34. Therefore it shall be considered that cost of spare parts is included in this if required. (ii) Periodical maintenance shall only be carried out by the authorsied representative of the original equipment manufacturer(OEM) of the plant.(iii) Electricity and water for maintenance of the plant will be supplied by the department free of cost at one location shown on site by the Engr-in-Charge.(iv) Keeping up of the maintenance record and the parameters of Solar PV power plant including ED/ MES shut down details shall be maintained by the contractor as directed by the Engineer-in-Charge. Any defects / short comings noticed shall be intimated to the department immediately
Contract Date: Jul 01, 2025 Contract Value : 4.80 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
14.
Public Administrative Department #7491419 AOC
Tender For Annual Maintenance Of Electric Department For Year 2025-26 - Supplying anderecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON. 3 Supplying and erecting HMS PVC conduit FRLS grade25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. 4 Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON. 5 Supplying anderectingPVCtrunking (PVC casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 6 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 7 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 8 Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 9 Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 10 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 11 Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 12 Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 13 Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 14 Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 15 Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 16 Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 17 Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 18 Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 19 Supplying and erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 20 Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 21 Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 22 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV 23 Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV 24 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 25 Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 26 Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 27 Supplying and erecting mains withWP 3 x 4 sq. mm. 1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 28 Supplying and erecting mains withWP 3 x 6 sq. mm.1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 29 Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 30 Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. 31 Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. 32 Supplying and erectingmodular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete. 33 Supplying and erecting modular type Two way switch 6A / 10A (2 Module),duly erected on provided plate and box with wiring connections complete. 34 Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete. 35 Supplying and erectingmodular type switch one way 16 / 20 A,duly erected on provided plate and box with wiring connections complete with neon indicator. 36 Supplying and erectingmodular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 37 Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 38 Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 39 Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 40 Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. 41 Supplying and erecting PVC Surface modular switch box with double mounting plate for 2module duly erected. 42 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. 43 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. 44 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. 45 Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. 46 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12module duly erected. 47 Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected. 48 Supplying and erectingmodular pop up Box 8 module erected with providedAV/ HDMI , RJ 45,6 A electricalsockets and switch on provided table. 49 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 50 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm(2+1E) FRLSH grade copper wire, modular type switch,earthing and required accessories as per specification No: WG-PW/SW 51 Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW 52 Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 53 Supplying and erectingrectangular shaped LEDPanel Light(1200mm X 300mm) Max. 35 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 54 Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. 55 Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty. 56 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 57 Supplying and erecting condenser 4 microfarad for fluo. Fitting as per specification no FG-FG/AS7. 58 Supplying and erecting integrated LED street light fitting18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing,having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 59 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification NoFG-ODF/FLS2. 60 Supplying and erecting integrated LED street light fitting26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing ,having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 61 Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 62 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 63 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 64 Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 65 Supplying and erecting integratedLED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 66 Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 67 Supplying and erecting integrated LED street light fitting 130-140W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 15600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 68 Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 69 Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 70 Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 71 Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 72 Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 73 Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 74 Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 75 Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 76 Supplying and erecting integrated LED Post Top45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser,having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification NoFG-ODF/FLS2. 77 Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lampon provided pipe as per specification No. FG-ODF/GLT 78 Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT 79 Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG-ODF/PTL 80 Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FG-ODF/PTL 81 Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL 82 Supplying and erecting integrated LED Highbay Fitting70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 83 Supplying and erecting integrated LED Highbay Fitting100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 84 Supplying and erecting integrated LED Highbay Fitting135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,havingsystem lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 85 Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 86 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 87 Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB 88 Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB 89 Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC 90 Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC 91 Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC 92 Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC 93 Supplying and erecting Control gear 1x250W for HPSV/MH lamp with all accessories for NON Integral Flood light fittings suitable for complete 94 Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 1x400W HPSV/MH lamp with all accessories complete. 95 Supplying and erecting Control gear for NON Integral Flood lightfittings suitable for 2x250W HPSV/MH lamp with all accessories complete. 96 Supplying and erecting Control gear for NON Integral Flood light fittings suitable for2x400W HPSV/MH lamp with all accessories complete. 97 Supplying and erecting electronic type Driver for Outdoor LED Fittingsupto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 98 Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 99 Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 100 Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 101 Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 102 Supplying and erecting electronic type Driver for Outdoor LED Fittings151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 103 Supplying & erecting 0.5W, 230V integral type LED Lamp suitable for B-22/E-27 base. 104 Supplying and erecting Pigmy /candle lamp miniature type coloured / white. 105 Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 106 Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 107 Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 108 Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 109 Supplying & erecting18W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 110 Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. 111 Supplying and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPMwithoutspeedregulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. 112 Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation. 113 Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. 114 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. 115 Supplying and erectingenergy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 116 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF 117 Supplying and erecting condenser 2.5 micro farad for ceiling fan 118 Erection ofdepartmentallysupplied ceiling fan with necessary materials complete. 119 Erectionofdepartmentallysupplied exhaust fan with necessary materials complete. 120 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. 121 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. 122 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. 123 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 32mm complete. 124 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 35mm complete. 125 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 42mm complete. 126 Supplying and erecting 12V/130Ah to 135Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 127 Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 128 Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 129 Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 130 Providingservicing of 1/1.5/2/3 TR capacity split/window air conditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit complete and submitting report to Engineer incharge. 131 Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and plastic material. 132 Providing annual comprehensive maintenance contract for 1.5TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 133 Providing annual comprehensive maintenance contract for 2TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 134 Providing annual comprehensive maintenance contract for 3TR to 4.5TRsplit/tower/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material 135 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1TRby new one of same capacity with guarantee for one year with provided refrigerant complete. 136 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1.5TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 137 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 138 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2.5TR to 4.5TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 139 Providing flushing out cooling coil and condenser coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure, complete. 140 Providing brazing pipes and checking leakages in the split/window unit duly with dry nitrogen pressure, complete. 141 Providing replacement of unserviceable starting relay for AC unit. 142 Providing replacement of unserviceable starting capacitor for AC unit. 143 Providing replacement of unserviceable running capacitor for AC unit. 144 Providing replacement of unserviceable fan motor capacitor for AC unit. 145 Providing replacement of unserviceable PCB for AC unit upto 3TR capacity. 146 Providing repair of faulty PCB for AC unit upto 3TR capacity. 147 Supplying and installing of new fan motor for condenser for air conditioning unit 148 Supplying and installing of new fan motor for indoor unit of air conditioner up to 3TRsuitable to operate on 230/250V,A.C. or 280-340V DC supply having 4 to 8 poles as per requirement. 149 Supplying and installing new fan blade outdoor unit for AC unit. 150 Providing replacement of blower of indoor unit for AC unit. 151 Providing replacement of remote of indoor unit for AC unit. 152 Providing vaccumising the airconditioner system and charging with refrigerant R32 for AC unit. 153 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. 154 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 1TR window/split AC unit. 155 Providing vaccumising the airconditioner system to 200 micron and charging with R32 refrigerant for 1.5TR window/split AC unit. 156 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 2TR window/split AC unit. 157 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 refrigerantfor 3TR window/split AC unit. 158 Providing replacement of existingunserviceablecompressor of 40 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 159 Providing replacement of existingunserviceablecompressor of 60 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 160 Providing replacement of existing unserviceable compressor of 150 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 161 Providing replacement of existingunserviceable condenser coil of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 162 Providing replacement of existing unserviceable SS water tap of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 163 Providing replacement of existingunserviceable relay40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 164 Providing replacement of existingunserviceablethermostat of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 165 Supplying and erecting candle filter with filter pot for water cooler. 166 Supplying and erecting connector pipe for candle filter of water cooler. 167 Providing replacement of base tray of water cooler of any capacity. 168 Supplying and erecting quartz electronic timeswitchhaving 24 hour dial to work on 250 V 50 cycle AC having built in rechargeablenickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor. 169 Supplying and erecting two pole power contactor 230 V, 32 A for time switch complete erected on provided wooden block/ box, with necessary materials. 170 Supplying and erectingfour pole power contactor 430 V, 16 Afor time switch complete erected on provided wooden block/ box, with necessary materials. 171 Supplying and erectingfour pole power contactor 430 V, 40 Afor time switch complete erected on provided wooden block/ box, with necessary materials. 172 Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light asper dailysunset and sunrise respectively automatically having 4digitLEDcontinuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box. 173 Supplying &erecting four poleON LOAD changeover switch, 415V,100A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 174 Supplying &erecting four poleON LOAD changeover switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 175 Supplying &erecting four poleON LOAD changeover switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 176 Supplying &erecting four poleON LOAD changeover switch, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit,rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 177 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 100-125A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging,connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 178 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging,connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 179 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB 180 Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 181 Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 182 Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 183 Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 184 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 185 Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 186 Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 187 Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 188 Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 189 Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 190 Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 191 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB 192 Supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40Awith required wiring connections and lugs etc. in provided distribution board. 193 Supplying, erectingand marking triplepoleisolatorsonlyswitch versionofminiaturecircuitbreaker of 40A with required wiring connections and lugs etc. in provided distribution board. 194 Supplying, erecting and markingtriple pole isolators only switch version of miniature circuit breaker of 63Awith required wiring connections and lugs etc. in provided distribution board. 195 Supplying, erecting and markingtriple pole isolators only switch version of miniature circuit breaker of 100Awith required wiring connections and lugs etc. in provided distribution board. 196 Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 197 Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63Ain provided distribution board. 198 Supplying, fixing and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS 199 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS 200 Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 201 Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 202 Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plugtop with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. 203 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 204 Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 205 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 206 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 207 Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 208 Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB 209 Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB 210 Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivitycomplete as per specification no. SW-RCCB/RCCB 211 Providing, erecting& commissioning 4 pole RCCB 100A, with added immunityto avoid DC pulse tripping with 30/100/300 mA sensitivitycompleteas per specification no. SW-RCCB/RCCB 212 Supplying and erecting porcelain base iron clad cut out HC type 415V, 16A erected on polished wooden block. 213 Supplying and erecting porcelain base iron clad cut out HC type 415V, 32Aerected on polished wooden block. 214 Supplying and erecting porcelain base iron clad cut out HC type 415V, 63Aerected on polished wooden block. 215 Supplying and erecting porcelain base iron clad cut out HC type 415V, 100Aerected on polished wooden block. 216 Supplying and erecting porcelain base iron clad cut out HC type 415V, 200A erected on polished wooden block. 217 Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. 218 Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 219 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade& Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint,with suitable number of ways andwith SMC/DMC Insulators and accessories of suitable ratingcomplete as per specification no. CP-BB 220 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade& Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint,with suitable number of ways andwith SMC/DMC Insulators and accessories of suitable ratingcomplete as per specification no. CP-BB 221 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 222 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 223 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 224 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 225 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 226 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core120sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 227 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 228 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 229 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 230 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 231 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 232 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 233 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 234 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wirearmoured (strip) cable 1100 V 2 core 4sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 235 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 236 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 237 Supplying & erecting G.I. pipe‘A’ class 50 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE 238 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 239 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 90 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 240 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mmoutside dia. double wall corrugatedpipes (DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 241 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wallas per specification No. CB-SB 242 Supplying & erecting crimping type copper lugs for cable up to 16 sq mm completeas per specification No. CB-CL/CU 243 Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm completeas per specification No. CB-CL/AL 244 Supplying & erecting crimping type aluminium lugs for cable25 sq mm completeas per specification No. CB-CL/AL 245 Supplying & erecting crimping type aluminium lugs for cable35 sq mm completeas per specification No. CB-CL/AL 246 Supplying & erecting crimping type aluminium lugs for cable50 sq mm completeas per specification No. CB-CL/AL 247 Supplying & erecting crimping type aluminium lugs for cable70 sq mm completeas per specification No. CB-CL/AL 248 Supplying & erecting crimping type aluminium lugs for cable95 sq mm completeas per specification No. CB-CL/AL 249 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 250 Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 251 Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 252 Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 253 Providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL 254 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 255 Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 256 Supplying and erecting 3 phase 5 core 16 sq.mm. (3x16+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 257 Supplying and erecting 3 phase 5 core 25 sq.mm.(3x25+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 258 Supplying and erecting 12 Way AB cable distribution box on provided pole with necessary accessories as per specification no. OH-ABC/JBS 259 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP 260 Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP 261 Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. 262 Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water,Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC 263 Supplying & erecting Fully Automatic Star/delta starter suitable for12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. 264 Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 265 Making trench in soft soil having 0.75 m depth and minimum0.3 m widthfor laying providedcables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 266 Making trench in Hard murum/Tar roadhaving 0.75 m depth and minimum0.3mtr width as per IS for laying provided cables up tovoltage level1.1Kv cable complete as per specification No. CW-EXN-CTR 267 PVC Insulation Tape 268 Supplying and erecting electronic type LED Strip for Outdoor LED Fittingsupto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 269 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 270 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 271 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 272 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 273 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 274 SUPPLY ofman power - electrician/wireman ( technician/lineman)for fault finding ,street light maintenance, garden maintenance, office maitenance, new light installation/replacement , mini Highmast light maintenanace.installation and replacing of street phase and underground cable, street light point on off 275 Supply ofman power - ( helper) for light chekerand tohelp technician/lineman
Contract Date: Jun 18, 2025 Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
15.
Public Administrative Department #7251402 AOC
Tender For Providing Electrical Material ,Erecting Electrical Work And Repairing Of Electrical Equipment Of Municipal Council Chalisgaon For Fy 2025-26-2 Supplying 1.5 Sq mm service wire Bundle (2CORE) 90 Mtr 3 Supplying 2.5 Sq mm service wire Bundle (2CORE) 90 Mtr 4 Supplying 4 Sq mm service wire Bundle (2CORE) 90 Mtr 5 Supplying 6 Sq mm service wire per (2CORE) 90 Mtr 6 Supplying 10 Sq mm service wire (2CORE) 90 Mtr 7 Supplying mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW 8 Supplyin mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/BW 9 SupplyingPVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 10 Supplying 6 to 32 A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. 11 Supplying40A to 63A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. 12 Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ tripalarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 13 Supplying LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete 14 Supplying Fuse bridges with base HC type fuse links 240V 63A erected on polished wooden block complete 15 Supplying 4 pole power contactor 63 A with coil voltage of 220/240 V 16 Supplying 4 pole power contactor 80A-130A with coil voltage of 220/240 V 17 Supplying quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating upto 16A to use independently or in conjunction with contactor. 18 Supplying 12 V/150Ah tubular battery withbattery terminal wire, duly charged complete with 36 months warranty complete 19 Supplying & erecting 12 V 88 Ah heavy duty plate type Battery with terminal wire duly charged complete suitable for DG set with warrantee for 3 years 20 Supplying regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF 21 Providing bracket fan 400 mm. sweep A. C. 230volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard with regulator and moisture proof treatment to winding and with ‘E’ class insulation. 22 Supplying fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner. 23 Supplying 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base. 24 MODE OF WORK - Supplying,erecting and comissioning part only 25 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto themax load of 12 kW on provided iron frame / CC foundation complete. 26 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 27 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 28 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 29 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 30 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 31 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 32 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 33 Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE(As per CSR 21-22 7-6-2) 34 Supplying and erecting Architectural pole of 4mtr height,pole placed with a aluminium/cast iron embellishment on the bottom & middle section for aesthetic & decorative purpose,pole shall have aluminium/cast iron casting on the base middle and on the joint giving it decorative look,the base aluminium/cast iron casting shall 148OD with aheight 180mm the casting will have ring on the top 20mm thickness,the middle Al/cast iron Casting shall be of conical design with bottom section of 145 OD having 3 ring of 15mm each. the conical casting shall taper for 145 OD on bottom to 92mm on top ,the pole with inbuilt junction box to fix 32 amp connectors & 6 amp MCB inside cut window of the bottom pipe with suitable size (as per attached Drawing)(Non DSR item ) 35 Supplying and Erecting attractive/decorative type of bracket with reducer/expander for holding decorative fixture on provided main pole having all the arrangement perpendicular to ground ,the bracket type is the double Arm Shall have span with 1000mm with in the middle made of 8 mm rod with flower leaf design (as per attached Drawing)(Non DSR item ) 36 Supplying and Erecting attractive/decorative type of bracket with reducer/expander for holding decorative fixture on provided main pole having all the arrangement perpendicular to ground ,the bracket type is the single Arm Shall have spanwith in the middle made of 8 mm rod with flower leaf design (as per attached Drawing)(Non DSR item ) 37 Supplying and Erecting of decorative luminaire made of Spun aluminium body with pressure die-cast heat management(PDCHM) and the IP optical Compartment with high power LED is comprised of deep drawn chemically polished and co-extruded thransformed polycarbonate protector stabilzed agent UV rays Suitable for 40-60 W LED fitting should be hangging type mounting decorative fixture with inbuilt Driver with efficiency >0.9 and having surge protection device of 10 KVA colour temperature 3000K/4000K/5700K natural day light LED,LED to be osaram/ Cree/Bridgelux & driver to be make with philips/Fulham/osaram(as per attached Drawing)(Non DSR item) 38 MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).(As per CSR 21-22 16-3-9) 39 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete(As per CSR 21-22 7-6-9). 40 Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP (As per CSR 21-22 9-1-4) 41 Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 42 Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface. 43 Supplying LED UP down light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface. 44 Supplying and erecting LED flexible strip light 5m length upto 25W conforming IP 65 of any colour with driver complete. 45 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 46 MODE OF WORK - Repairing works only 47 Rewinding motor of the 1200/1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc.Testing of fan for original speed and consumption with guarantee for one year. 48 Repairing of Generator focus lamp with Chock,connector coil Etc 49 Servising of Generator focus lamp 50 MODE OF WORK - Repairing and providing municipal council AC units 51 Providing servicing of 1/1.5/2/3 TR capacitysplit/window air conditioning unit complete with allnecessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to Engineer incharge. 52 Providing flushing out cooling coil and condensor coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure in an approved manner 53 Providing brazing pipes and checking leakages in the split/ window unit duly with dry nitrogen pressure in an approved manner. 54 Providing replacement of existing unservicablerotary/scroll compressor of air conditioner 1.5 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 55 Providing replacement of existing unservicablerotary/scroll compressor of air conditioner 3 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 56 Providing replacement of unserviceable starting relay for AC unit. 57 Providing replacement of unserviceable starting/running capacitor for A/C unit. 58 Providing replacement of unserviceable fan motorcapacitor for A/C unit. 59 Providing replacement of unserviceable PCB for A/C unit upto 3 TR capacity. 60 Providing repair of of faulty PCB for air conditioning unit upto 3 TR capacity. 61 Supplying and installing of new fan motor for condenser for air conditioning unit 62 Supplying and installing of new fan motor for indoor unit of air conditioner up to 3 TR suitable to operate on 230V to 250V AC or 280V to 340V DC supply having 4 to 8 poles as per requirement. 63 Supplying and installing new fan blade outdoor unit for air conditioning unit. 64 Providing replacement of blower of indoor unit for air conditioning unit. 65 Providing replacement of remote of indoor unit for air conditioning unit. 66 Providing and fixing indoor plastic cabinet with all accessories 67 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1.5TR window/split air conditioning unit. 68 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 3TR window/split air conditioning unit. 69 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position asper specification no. APAC/ WAC 70 Providing servicing of 1/1.5/2/3 TR capacity split/window airconditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to Engineer incharge. 71 Providing annual comprehensive maintenance contract for 1.5TRsplit/window air conditioning unit complete as per terms and conditions. Jobincludes 1) quarterly servicing 2) on call repair 3) replacement of all spares within24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material. 72 Supplying, installing, testing & commissioning cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 2.5TR to 2.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser, dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. APAC/ WAC 73 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 3.4TR to 3.9TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noiselevel maximum 50dBA at position as per specification no. APAC/ WAC 74 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC 75 MODE OF WORK - ELECTRICAL FITTING PART ONLY 76 Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. 77 Supplying and erecting UPVC reinforced flexible conduit 31/32 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete. 78 Supplying and erecting HMS PVC conduit 32 mm dia. with PVC accessories on wall / ceiling as per specification No:WG-MA/CON. 79 Point wiring for independent plug in 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as perspecification No: WG-PW/SW 80 Wiring for plug on board with Switch socket, copper wiring and earthing as per specification No: WG-PW/SW 81 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 82 Point wiring in PVC trunking (casing-capping) with 1.5sq.mm (2+1E) FR grade copper wire, flush type switch,earthing and required accessories as per specification No: WGPW/SW 83 Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR/ FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW 84 Supplying and erecting Ceiling rose / Batten holder /Slanting holder / hanging cord switch / hanging bell push/ pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. 85 Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 86 Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board. 87 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected. 88 Supplying and erecting PVC Surface modular switch box with double mounting plate for 13modules duly erected. 89 Supplying and erecting PVC Surface modular switch box with double mounting plate for 18 modules duly erected. 90 MODE OF WORK - Repairing and providing LED lights only 91 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 92 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 26W-45W suitable to operate on 230V A.C. 50 Hz. having pf>0.95 and THD<10%. 93 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 46W-75W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 94 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 76W-100W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 95 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 101W-150W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 96 Repairing for 18 to 45 W LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 97 Repairing for 50 to 75 W LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 98 Repairing for76 W to 100wLED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 99 Repairing for76 W to 150w LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 100 Repairing for 100 to 120 W flood light plate with al required accessories 101 providing for 100 to 120 W flood light plate with al required accessories 102 providing for 18w to 45 W flood light plate with al required accessories 103 providing for 46wto 75 W flood light plate with al required accessories 104 providing for76w to 90 W flood light plate with al required accessories 105 Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 106 Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2 107 Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 108 Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140 270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 109 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ classG.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 110 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. 111 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 112 MODE OF WORK - Shifting of highmast/RSJ/round pole 113 Dismentaling and Erecting upto20 m (clear height) motorized/non motorized high-mast on provided foundation with carefully dismentallation and erection of wire,luminaries etc complete 114 Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per designcomplete (upto 20 m raising lowering high mast) . 115 providing wire rope for raising lowering high mast 116 Providing luminaries ring for raising and lowering high mast 117 Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ(for 8 mtr) 118 Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP 119 Painting of steel tubular / rail / RSJ pole above 6.0 length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CW -PTG/PTP. 120 Supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 121 Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 122 Supplying and erecting 3 phase 4 core 70 sq.mm. (3x70+1x50) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 123 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishingcomplete. (above 6 m to 9 m poles) 124 Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). 125 MODE OF WORK - Extra-other accessories 126 Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC 127 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 128 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 129 GOVERNMENT OF MAHARASHTRAPUBLIC WORKS DEPARTMENT(ELECTRICAL WING)CURRENT SCHEDULE OF RATES for 2022-2023(Note :- use of this item in critical conditionfor detail Refer DTN)
Contract Date: Apr 17, 2025 Contract Value : 10.28 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
16.
Public Administrative Department #3719959 AOC
Supply Of Electrical Materials For The Financial Year 2023-24 Under Chakan Nagar Parishad Electricity Department- 1 Supplying & Erecting Crimping Type Copper Lugs For Cable Up To 16 Sq. Mm. Complete As Per Specification No. 2 Supplying & Erecting Crimping Type Aluminium Lugs For Cable Up To 16 Sq. Mm. Complete As Per Specification No. Cb-Cl / Al 3 Supplying & Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wgma / Bw 4 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Anyother Places. As Per Specification No: Wg-Ma / Bw 5 Supplying, Erecting & Terminating Xlpe Armoured Cable 2 Core 6 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No.Cb-Lt / Al ( 6 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire. 7 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 8 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 10 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No.Cb-Lt / Al 9 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 16 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 10 Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendant Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block / Pvc Junction Box 11 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 12 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 32Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 13 Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 14 Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Classinsulation. 15 Supplying Pedestal Fan 400 Mm. 230 Volts 50 Cycles Oscillating Type Completewith Guard And Regulator 3 Meter. Of Flexible Wire And Hand Shield Type 3 Pin Plugtop. 16 Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 375 / 380Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg Fn / Exf 17 Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles1200 Mm, Max. Energy Consumption Of 28W Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speedregulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Controlpcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf 18 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W 75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Th 19 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W 45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And T 20 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 21 Supplying & Erecting Inverter Led Batten 20W Tube Light Fitting With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver, Min. 2600Mah Lithium Ion Battery With Charging Time Of 8-10 Hours And Backup Time Of Min. 3 Hrs. With Minimum 25% Of Initial Watts Having Luminous Efficacy Of 100Lumen / Watt, Cri>80, Cct Of 6500K And Thd<=20% Having Useful Life Of Minimum 25000 Hrs. With Overheating Protection With 2 Years Warranty 22 Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22W With High Transitivity Diffuser With System Lumens Output Of Min.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of 200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. 23 Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuserhaving System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. 24 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 25 Supplying & Erecting Integral Post Top Lantern Fixtures ( Light House Type ) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl 26 Supplying And Erecting Isi Mark Modular Type Switch 16A Dulyerected On Provided Plate And Box With Wiring Connectionscomplete. 1-8-2 27 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safetyshutter, Duly Erected On Provided Plate And Box With Wiring Connectionscomplete. 28 Supplying And Erecting Pvc Surface Modular Switch Box With Doublemounting Plate For 12 Module Duly Erected. 29 Supplying And Erecting Single Pole And Neutral Distribution Board ( Spndb ) , With 2 Ways For Incoming And 10 Ways ( 10 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb 30 Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching ?On? & Switching ?Off? Street Light As Per Daily Sunsetand Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10 Hrs Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacitycontactors Timer Erected In Provided M.S. Box In An Approvedmanner. 31 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switch Complete Erected On Provided Wooden Block / Box, Withnecessary Materials 32 Supplying And Erecting Two Pole Power Contactor 230 V, 32 A For Time Switchcomplete Erected On Provided Wooden Block / Box, With Necessary Materials. 33 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb 34 Supplying, Erecting & Marking Spmcb 40A To 63A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb 35 Supplying And Erecting Cupboard For Enclosing Switchgears Or For Any Other Purpose Made From Selected Marine Plywood Planks 19 Mm Thick Duly Varnished / Painted From Inside And From Outside With Brass Hinges And Locking Arrangement With Suitable Lock With Keys In Duplicate. Cupboard Shall Be Dulygrouted With Suitable Size Of Iron Work In Wall At The Bottom. ( Size Of Cupboard Shall Be Specified In The Estimate ) 36 Epoxy Painting On Both Side Of Approved Colour Shade Of Provided Iron Work / Ms / Crca Sheet Steel Work Complete Along With Anti-Rust Treatment Complete. 37 Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mmdia. G.L. Rod Complete With All Materials As Per Specification No. 38 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. 39 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. 40 Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersibletype Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assemblycomplete. 41 Supplying & Erecting D.O.L Starter Suitable For 250 V, Single Phase 50 Cycleswith Overload Element With Necessary Materials And Connected To Supply Up To 3H.P. 42 Supplying & Erecting Automatic Control Panel For 3 Ph, 415 Volt, A.C.Submersible / Centrifugal Pump Set Up To 7.5 Hp - 10 H.P. Consisting Of Dolstarter Having Relay Range 13-21 Amp, S.P.P., Combined Ammeter / Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phasereversal, Phase Imbalance Etc. 43 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 230V, Single Phase 50 Cycles A.C. Supply Of 1.125Kw / 1.5Hp With Discharge 198 / 50 Litres Per Minute ( Lpm ) ) For Head Of 15 / 37.5 M & 40 Mm Suction / 32 Mm Delivery Pipe On Provided C.C.Foundation As Per Specification No. Wp-Cgp 44 Providing Annual Comprehensive Maintenance Contract For 1.5Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Jobincludes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheetmetal Work And Plastic Material. 45 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Ofradiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Perspecification No. Gen-Ser-Amc 46 Providing Vehicle Mountedhydraulic Ladder On Hour Basis With Transportation , Fuel And Driver Operator 47 Providing Electrical Grinder Machine With Wheel / Disc For Cutting Wood , Metal, Brick Etc 48 Electric Drill Machine With Tool Kit 49 Mnx 9-40Amp Contactor Operating Coil 50 Mnx 50-80Amp Contactor Operating Coil 51 Supplying And Erecting 1 Phase 2 Core 16 Sq.Mm. ( 1X16+1X25 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 52 Foundation Plate, Bolt As Per Requirement 53 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 M Length Along Withstreet Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Completeas Per Specification No Cw -Ptg / Ptp. 54 Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is :47705 Suitable For Working Up To 22 Kv Supply Complete. 55 Supplying Standard First Aid Box With Necessary Antiseptic Cream, Medicine Foruse On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Usebandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc. ( All Above Contents Shall Be Of Standard Makes ) 56 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cmdeep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishingcomplete. ( Above 6 M To 9 M Poles ) 57 Making Cement Concrete Foundation In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm.Stone Metal Duly Plastered With Necessary Curing For Complete. ( Pole Muffing Orany Other Purpose ) . 58 Providing, Commissioning And Maintaining Additional Ip Based 2.0 Mp, Full Hd, Ir Ip Ptz Camera In Existing Cctv System With Necessary Mains, Switchgears On Hire Basis For One Day. 59 Providing Temporary Illumination Consisting Of Flood Light Fitting 200 W Complete Led Fitting With Lamp, Complete Required Switchgear Erected And Dismantled Without Using Scaffolding Upto Three Days. 60 Providing And Maintaining Temporary Cordless ( Hand Type Or Lape Type ) Super Sensitive Huf Microphone ( 1 No Stand By ) For One Day. 61 Providing, Maintaining And Operating Temporarypublic Address System On Hire Consisting 02 Nos. Solid State Heavy Wattage Amplifier 250 Watts ( One For Working And Another For Stand By Emergency ) Working On Ac / Generator And 24 Volt Car Battery Supply, 06 Nos. Of Matching Of 100 Volt Line ( 200 Watts ) Box Type Speakers / Sound Column, 02 Nos Super Sensitive Microphone With Suitable Size Of Microphone Holding Stand.The System Shall Be In A Fully Automatic Change Over Operation In Case Of Failure Of Supply For One Day. 62 Hiring Charges For Supplyingand Maintaining 230V, 50 Cycles Ac Generatingset1 To 2 Kva Capacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 63 Hiring Charges For Supplyingand Maintaining 230 / 415 V, 50 Cycles Acgenerating Set3 To 10 Kvacapacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 64 Hiring Charges For Supplyingand Maintainingtemporary415v, 50Cyclesacgenerating Set 11 To 25 Kva ( Excluding 25 Kva ) Capacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 65 Providing Temporary Illumination Consisting Of White / Colour Series Lights 50 Nos. With Miniaturelampsof 6.2 To 16V With Required Switchgears Erected And Dismantled With Rotor Effect As Approved Without Scaffolding Upto Three Days. 66 Providing Temporary Illumination Consisting Of Led Rope Light Having 2 To 5 W Capacity Per Meter And Consisting Suitable Power Adaptor With Mains, Switchgears Erected And Dismantled With Using Scaffolding And Maintaining The Same Upto 3 Days
Contract Date: Mar 15, 2024 Contract Value : 50.00 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
17.
Public Administrative Department #3510915 AOC
Tender For Annual Tender Of Electric Maintenance And Labour Supply, Test , Supplying And Erecting Pvc Trunking ( Pvccasing-N-Capping ) Ofsize25 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. , Supplying And Erecting Pvc Trunking ( Pvccasing-N-Capping ) Ofsize32 Mm With Accessorieson Wall / Ceiling As Per Specification No: Wg-Ma / Con. , Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlshcopperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X1.5 Sq.Mm Frlshcopperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 2X2.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X2.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 3X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 4X16 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Strandedcopper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm ( 50 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Strandedcopper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Mains With Wp 2 X 2.5 Sq. Mm. 1100 V Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains Withwp 3 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains Withwp 3 X 6 Sq. Mm.1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erectingmodular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch 16Aduly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Bell-Push 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Bell-Push With Indicator 2 Modules 6A / 10A, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Two Way Switch 6A / 10A ( 2 Module ) , Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch 16 / 20 Awith Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch One Way 16 / 20 A, Duly Erected On Provided Plate And Box With Wiring Connections Complete With Neon Indicator. , Supplying And Erectingmodular Type D.P. Switch 32A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type 3 Pin 6Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type 3 Pin 6 / 16Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 16 / 18 Module Duly Erected. , Point Wiring For Ceiling Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthingand Required Accessories As Per Specification No: Wg-Pw / Sw , Point Wiring For Independent Plug In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw , Wiring For Plug On Board Withswitch Socket Surface / Concealed Type, Copper Wiring And Earthing And With Modular Accessories As Per Specification No: Wg-Pw / Cw , Supplying And Erectingled Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erectingrectangular Shaped Ledpanel Light ( 1200Mm X 300Mm ) Max. 35 Whaving Crca Powder Coated Housing, Polystyrene Diffuser Havingsystem Lumens Output Of Min. 4200 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erectingbulk Head Led Fittingmax. 10Wwith High Transitivity Diffuser Withsystem Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd<10%, P.F. >0.95, Operating Range Of140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of50, 000 Hrs. At L70b50, Including Driver, Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With 3 Years Warranty. , Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22Wwith High Transitivity Diffuser Withsystem Lumens Output Ofmin.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. , Supplying And Erecting Condenser 4 Microfarad For Fluo. Fitting As Per Specification No Fg-Fg / As7. , Supplying And Erecting Integrated Led Street Light Fitting18 To 22W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 1800 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting26 To 30W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing , Having System Lumens Output Of Min. 2600 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 85-90W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 9300 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integratedled Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 120W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 13000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 130-140W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 15600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 160-170W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 19000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 30W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 3000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 120W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min.14500 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Post Top45w Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30, 000 Hrs. At L50b50 , Including Driver Complete With 2 Year Warranty As Per Specification Nofg-Odf / Fls2. , Erecting The Departmentally Supplied Wp Led Street Light / Flood Light Fitting Upto 80W. , Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above 80 To 150W . , Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above 150 To 400W . , Supplying And Erecting Gate / Garden Light Fitting With 200Mm Dia. Glass Bowl Suitable For Upto 12W Led Lampon Provided Pipe As Per Specification No. Fg-Odf / Glt , Supplying And Erecting Gate / Garden Light Fitting With 300Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fg-Odf / Glt , Supplying & Erecting Integral Post Top Lantern Fixtures ( Mushroom Type ) Suitable For Led Lamp Upto 12 W Consisting Of Clear Acrylic Top Cover, Cast Aluminium Pole Cap Complete With Accessories On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures ( Globe Type ) Suitable For Led Lamp Upto 12 W Consisting Of Aesthetic Round Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures ( Light House Type ) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc , Supplying And Erecting Street Light Bracket For Erection Of Double Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittingsupto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings151w-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying & Erecting 0.5W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying And Erecting Pigmy / Candle Lamp Miniature Type Coloured / White. , Supplying & Erecting 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 14W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting18w, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. , Supplying And Erectingenergy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm Complete Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm, Max. Energy Consumption Of28w Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speed Regulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Control Pcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying And Erecting Condenser 2.5 Micro Farad For Ceiling Fan , Erection Ofdepartmentallysupplied Ceiling Fan With Necessary Materials Complete. , Erectionofdepartmentallysupplied Exhaust Fan With Necessary Materials Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 12Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigeranthaving 22Swg Thickness And Inner Dia / Size 16Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 22Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 32Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 35Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 42Mm Complete. , Providingservicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Air Conditioning Unit With All Necessary Material. Job Includes Checking Of Performance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unit With Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unit Complete And Submitting Report To Engineer Incharge. , Providing Annual Comprehensive Maintenance Contract For 1 Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Excludes Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 1.5Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 2Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 3Tr To 4.5Trsplit / Tower / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 1Trby New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 1.5Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2.5Tr To 4.5Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Flushing Out Cooling Coil And Condenser Coil Of Airconditioner Unit Refrigerant Pipes Internally With Dry Nitrogen Pressure, Complete. , Providing Brazing Pipes And Checking Leakages In The Split / Window Unit Duly With Dry Nitrogen Pressure, Complete. , Providing Replacement Of Unserviceable Starting Relay For Ac Unit. , Providing Replacement Of Unserviceable Starting Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Running Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Fan Motor Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Pcb For Ac Unit Upto 3Tr Capacity. , Providing Repair Of Faulty Pcb For Ac Unit Upto 3Tr Capacity. , Supplying And Installing Of New Fan Motor For Condenser For Air Conditioning Unit , Supplying And Installing Of New Fan Motor For Indoor Unit Of Air Conditioner Up To 3Trsuitable To Operate On 230 / 250V, A.C. Or 280-340V Dc Supply Having 4 To 8 Poles As Per Requirement. , Supplying And Installing New Fan Blade Outdoor Unit For Ac Unit. , Providing Replacement Of Blower Of Indoor Unit For Ac Unit. , Providing Replacement Of Remote Of Indoor Unit For Ac Unit. , Providing Vaccumising The Airconditioner System And Charging With Refrigerant R32 For Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For 1Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R32 Refrigerant For 1.5Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For 2Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 Refrigerantfor 3Tr Window / Split Ac Unit. , Providing Replacement Of Existingunserviceablecompressor Of 40 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existingunserviceablecompressor Of 60 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existing Unserviceable Compressor Of 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existingunserviceable Condenser Coil Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existing Unserviceable Ss Water Tap Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existingunserviceable Relay40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existingunserviceablethermostat Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Supplying And Erecting Candle Filter With Filter Pot For Water Cooler. , Supplying And Erecting Connector Pipe For Candle Filter Of Water Cooler. , Providing Replacement Of Base Tray Of Water Cooler Of Any Capacity. , Supplying And Erecting Quartz Electronic Timeswitchhaving 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeablenickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16A To Use Independently Or In Conjunction With Contactor. , Supplying And Erecting Two Pole Power Contactor 230 V, 32 A For Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying And Erectingfour Pole Power Contactor 430 V, 16 Afor Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying And Erectingfour Pole Power Contactor 430 V, 40 Afor Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying &Erecting Four Poleon Load Changeover Switch, 415V, 100A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is / Iec 60947-3 Part-1 / 3. , Supplying &Erecting Four Poleon Load Changeover Switch, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is / Iec 60947-3 Part-1 / 3. , Supplying, Erecting & Marking Spmcb 0.5A To 5A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Kain Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 6A To 32A, C-Serieswith Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 6 A To 32 A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Fpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Kain Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erectingand Marking Double Pole Isolator Only Switch Version Of Miniature Circuit Breakerof40awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erectingand Marking Triplepoleisolatorsonlyswitch Versionofminiaturecircuitbreaker Of 40A With Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingtriple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 63Awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingtriple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 100Awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingfour Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A In Provided Distribution Board. , Supplying, Erecting And Markingfour Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 63Ain Provided Distribution Board. , Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 2 Ways ( 2 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb , Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 6 Ways ( 6 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb , Supplying & Erecting Crca Sheet Metal Enclosures Of 1.2Mm Thickness With 20A, 2 Pin Plug & Earth Socket And 20A, 3 Pin Plugtop With 20A / 30A Single Pole Mcb Having Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka Complete Erected On Angle Iron / Gi Frame. , Supplying & Erecting Crca Sheet Metal One Way Enclosures Of 1.2Mm Thickness Suitable For Dp Mcb / Tp Mcb / Fp Mcb / Rccb / Rcbo Complete Erected On Angle Iron / Gi Frame. , Providing & Erecting 4 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact.Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb , Supplying, Erecting & Commissioning 2 Pole Rccb 63A, Electromagnetictype With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 63A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Completeas Per Specification No. Sw-Rccb / Rccb , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 16A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 32Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200A Erected On Polished Wooden Block. , Supplyinganderectingiron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron, Plates, Chequeredplates, Rods, Bars, Mspipes, Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. , Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supportswith Fabrication Ofboxes, Panelboards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment Andduly Powder Coated Or Paintedwith One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. , Supplying And Erecting Bus Bar Chamber Triple Pole With Neutral With Four Aluminium Bars, 500V, 100A Having 15Mm ( Width ) X 3 Mm ( Thickness ) , With 99.9 % Aluminium Purity As Per E91e Grade& Current Density 0.8 A Per Sq. Mm. Compliance To Is 5082 And Enclosure Fabricated With 16 Swg Crca Sheet And Epoxy Paint, With Suitable Number Of Ways Andwith Smc / Dmc Insulators And Accessories Of Suitable Ratingcomplete As Per Specification No. Cp-Bb , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core25 Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core35sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core50 Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core70sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core95sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core120sq. Mm. Aluminiumconductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core4sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core6sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core10sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core16sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core25sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core35sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wirearmoured ( Strip ) Cable 1100 V 2 Core 4Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 6Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying & Erecting G.I. Pipe‘A’ Class 50 Mmdia.Erectedfor Enclosingxlpearmouredcable On Wall / Poleas Per Specification No. Cb-Ce , Supplying Andlaying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. , Supplying & Erecting Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete On Pole / Wallas Per Specification No. Cb-Sb , Supplying & Erecting Crimping Type Copper Lugs For Cable Up To 16 Sq Mm Completeas Per Specification No. Cb-Cl / Cu , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Up To 16 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable25 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable35 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable50 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable70 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable95 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying And Erecting 3 Phase 5 Core 16 Sq.Mm. ( 3X16+1X25+1X16 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc , Supplying And Erecting 3 Phase 5 Core 25 Sq.Mm. ( 3X25+1X25+1X16 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc , Supplying And Erecting 12 Way Ab Cable Distribution Box On Provided Pole With Necessary Accessories As Per Specification No. Oh-Abc / Jbs , Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results Asper Specification No. Ea-Ep , Providingpipetype Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rodcomplete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Carrying Out Servicing Of Dg Set From 62.5 Kva To 200 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc , Supplying & Erecting Fully Automatic Star / Delta Starter Suitable For12.5 H.P To 15 H.P. For 3 Phase Squirrel Cage Motor Totally Enclosed With Overload And No Volt Relay Complete Erected On Provided Angle Iron Frame. , Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Making Trench In Soft Soil Having 0.75 M Depth And Minimum0.3 M Widthfor Laying Providedcables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr , Making Trench In Hard Murum / Tar Roadhaving 0.75 M Depth And Minimum0.3Mtr Width As Per Is For Laying Provided Cables Up Tovoltage Level1.1Kv Cable Complete As Per Specification No. Cw-Exn-Ctr , Pvc Insulation Tape , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittingsupto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings151w-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supply Ofman Power - Electrician / Wireman ( Technician / Lineman ) For Fault Finding , Street Light Maintenance, Garden Maintenance, Office Maitenance, New Light Installation / Replacement , Mini Highmast Light Maintenanace.Installation And Replacing Of Street Phase And Underground Cable, Street Light Point On Off , Supply Ofman Power - ( Helper ) For Light Chekerand Tohelp Technician / Lineman
Contract Date: Mar 06, 2024 Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
18.
Housing Urban and Rular Development #3373124 AOC
Tender For Maintenance Of Panampilly Nagar Office Complex- Guest House-1 Guest House Civil Works 2 15.2.2 : Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Leaner Mix ( Including Equivalent Design Mix ) 3 15.23.1 : Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 4 15.56 : Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 5 13.7.1 : 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand ) 6 15.12.1 : Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 7 15.12.2 : Of Area Beyond 3 Sq. Metres 8 13.18 : Neat Cement Punning 9 4.2.2 : Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor, Etc. Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing:1:11 / 2:3 ( 1 Cement : 11 / 2 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size ) 10 22.5 : Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 11 6.40 : Providing And Laying Gypsum Panel Partitions 100 Mm Thick With Water Proof Gypsum Panels Of Size 666X500x100 Mm, Made Of Calcite Phosphor Gypsum Fixed With Tongue And Groove, Jointed With Bonding Plaster As Per Manufacturers Specifications In Superstructure Above Plinth Level Up To Floor V Level. Gypsum Blocks Will Have A Minimum Compressive Strength Of 9.3 Kg / Cm2 12 6.41 : Extra For Gypsum Panel Partitions In Superstructure Above Floor V Level For Every Four Floors Or Part Thereof. 13 13.60.1 : Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 14 13.99.1 : Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 15 13.26 : Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 16 21.1.1.1 : Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Fixed Portionanodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15 ) 17 21.1.2.1 : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15 ) 18 9.100.1 : Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 19 21.3.2 : Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5.50 Mm Thickness 20 11.48.2 : Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 600X600 Mm 21 11.49.2 : Providing And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tiles 600X600 Mm 22 11.50 : Deduct For Not Grouting The Joints With White Cement And Matching Pigment In The Items Of Fixing Of Vitrified Tiles 23 8.31 : Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineerin-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 24 9.1.1 : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) .Second Class Teak Wood 25 9.53 : Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 26 Od271499 / 2023_2024 : Providing And Fixing Single Shutter Doors Of Engineered Wood For Opening Size Of 1000 Mm *2100 Mm Hinged Type Openable On One Side. The Door Shutter Shall Be Of 40 Mm Thickness ( Min ) With Perimeter Seal And Core Filling With Tubular Particle Board And Polished Veneer On Both Sides As Per Design / Shade As Selected. The Door Jambs Shall Be Of 125*45 ( Min ) . Architrave Shall Be Of 65*12 Mm And Shall Vary In Line With The Site Conditions. The Architrave Material Provided Shall Be Of Lvl ( Laminated Veneer Lumber ) . Rate Includes Fixing The Door Accessories. 27 9.23 : Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 28 Od271508 / 2023_2024 : Providing And Fixing Cup Board Shutters 18 Mm Thick, With Multi Wood Is: 12823 Marked, Exterior Grade ( Grade I Type Ii ) , Having One Side Decorative Lamination And Other Side Balancing, Including Iind Class Teak Wood Lipping Of 25 Mm Wide X12 Mm Thick With Necessary Screws And Bright Finished Stainless Steel Piano Hinges. It Also Includes Magnetic Catcher And Aluminum Handles And And Locking Arrangements Complete As Per Direction Of The Engineer -In-Charge. 29 9.82 : Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete. 30 9.92.1 : Providingand Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 31 Od3774 / 2022_2023 : Providing And Fixing Mosqito Net ( Steel ) For Windows And Doors Including Aluminum Sectionand All Fittings With Locking Arragement Approved By The Site Enginneer In Charge ( No Extra Cost Paid On This Account ) . 32 12.45.3 : Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With:12.5 Mm Thick Tapered Edge Gypsum Moisture Resistant Board 33 Od271634 / 2023_2024 : Providing And Fixing Of Podium Stand Made Up Of Hard Wood Of Size 120*60*40. It Includes One Drawer With Open Compartment And Complete As Per The Direction Of Engineer In Charge 34 10.25.1 : Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete 35 Toilet Andbathroom Fittings 36 9.117.2 : Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below ( Tolerance ±1 Mm ) , With Wall Thickness 2.0Mm ( ±0.2 Mm ) , Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size19 X 19 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 42X50 Mm 37 9.118.2 : Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride ( Pvc ) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm ( ± 0.2 Mm ) , With Inbuilt Decorative Moulding Edging On One Side.The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised / Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws.The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm ( ± 0.2 Mm ) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic / Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 38 17.81 : Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 39 17.28.2.1 : Flexible Pipe32 Mm Dia 40 17.29 : Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. 41 17.7.2 : Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 42 18.15.1 : Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore 43 18.8.2 : Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes 44 50.18.9.9.1 : Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf / Cm2 45 50.18.9.22.1 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 46 50.18.9.22.11 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Socket / Coupling 47 18.22.2 : Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet:150 Mm Diameter 48 18.53.1 : Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 49 18.21.1.1 : Providing And Fixing Uplasticised Pvc Connectionpipe With Brass Unions:30 Cm Length15 Mm Nominal Bore 50 50.17.1.5 : Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 51 50.17.1.1 : Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 52 50.17.1.2 : Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 53 50.9.15.2 : Supplying And Fixing 300 Mm Aluminium Aldrop 54 9.97.1 : Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 55 Electrical Works 56 Od275734 / 2023_2024 : Supply, Conveyance Installation Testing And Commissioning Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20 Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.
1200 Mm 1 X 20 W Led Tube With Fittings 57 1.33 : Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 58 Od273270 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Following Split Type High Wall Mounted Air Conditioner Unit With Cordless Remote Of Following Ratings Including Fixing Of Indoor & Outdoor Units, Initial Gas Charging As Per Manufacturer Standards, Giving Power Connection To Nearest Power Plug Point / Mcs, Connecting Indoor And Outdoor Units Using Hard Drawn Copper Refrigerant Pipes Insulated With Nitrile Rubber Or Equivalent Material Of Minimum 3 Mtrs, Pvc Insulated Flexible Copper Cable Of Minimum 3 Meters As Per Original Manufacturers Standards, Necessary Drain Water Line Using 20Mm Pvc Pipe Minimum 3 Mtrs. Necessary Opening On Wall Shall Be Made For Drawing Refrigerant / Power / Drain Lines And Shall Be Restored To Normal Using Cement Plastering. ( Drain Pipe Line Shall Be Properly Fixed And Clamped To Line And Level As Per The Direction Of Site Engineer In Charge ) . Approved Ot Equivalent Make Of 1.5Tr Twin Coil Capacity 5 Star Rated Air Conditioner Working On Single Phase 240 V, 50 Hz + / -1% Ac Supply With Approved Make External Stabilizer.
59 90.4.5.2 : Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizesusing Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 650 / 1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 60 Od273417 / 2023_2024 : Supply Of 18W Surface Recess Mounted Led Downlighter, High Efficiencyluminaire Wattage 18W. The Luminaire Should Have A Cri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Led Light Fixture Of 6000 K, Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. ( Make:Havells, Phillips, Wipro ) 61 Od273467 / 2023_2024 : Supply Of 9W Led Downlighter With A Nominal System Lumen Output Of Minimum 500 Lumens. System Wattage Should Not Exceed 9W. The Luminaire Shall Have A Rated System Lifetime Of 50, 000 Burning Hours. The Luminaire Should Have A Color Temperature Of 6000K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser. Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld80-530-Xxx-60-Xx*** Or Equivalent
62 Od273470 / 2023_2024 : Supply Of Mirror Light, High Efficiency With A Nominal System Lumen Output Of 900 Lumens. Luminaire Wattage Should Not Exceed 9W. The Luminaire Should Have A Cri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 2700 K, Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number D531027 Garnet 10W Of Wipro Make Or Equivalent.
63 1.10.2 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 64 1.24.1 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 65 1.24.3 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 66 1.24.4 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 67 1.24.5 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 68 1.27.1 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 69 1.27.2 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 70 1.14.1 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 71 1.14.2 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 72 1.14.3 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 73 1.17.3 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 1.5 Sq.Mm 74 1.21.1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 75 1.21.2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 76 2.7.6 : Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door 77 1.24.8 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push 78 2.12.1 : Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 79 2.14.2 : Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 80 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 81 1.25 : Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 82 1.38 : Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. 83 90.4.8 : Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Colour Washing Etc. As Required. 84 Od279204 / 2023_2024 : Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24 / 0.20Mm Pvc Insulated And Pvc
Sheathed 3 Core Round Copper Conductor Flex Wire , Conforming To Relevant Iss.150 / 155 Mm, Single
Phase Pvc Type Light Duty Exhaust Fan With Shutters
85 Od279297 / 2023_2024 : Supply, Installation, Testing And Commissioning ( Sitc ) Of Instant Water Geyser Of Capacity-3Ltr, Product Warranty-Min 2 Yrs, Heating Element Warranty-Min 2 Yrs, Tank Capacity-Min 5 Yrs Including Piping Accessories, Pressure Rating-Min 6.5 Bar, Stainless Steel Tank, Water Flow Rate-120 Ltr / Hr, Heating Element-Copper, Isi Certified ( Make:V-Guard, Crompton, Havells Or Equivalent ) As Per The Direction Of Engineer In Charge. 86 Od286554 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Hisense 44L, Single Door, Compact, Direct Cool Single 1 Star , Temperature Control, Metal Body , 201Kwh / Year , Ac 220-240, 50 Hz, Size 51*47*43.9, Weight 14 Kg, Warranty 1 Year On Refridgerator And 10 Years On Compressor From Hisense Refridgerator ( Silver, Rr60d4asb1 ) Or Equivalent As Per The Direction Of Engineer Incharge. 87 Od286663 / 2023_2024 : Supply , Installing , Testing, Commissioning Of Water Purifier-6 L Capacity Ro+Uf, Power-40-50 Wauto Shutoff And Overflow Protection, Filteration Capacity 8L / Hr , Fiter Life6000 Ltr Purifying Technology, Power -230 V , 50 Hz , 20V Make :Eureka Forbes Sure Delight Nxt 6 Or Equivalent, As Per The Direction Of Engineer In Charge. 88 1.56 : Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 89 1.57 : Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. 90 1.59 : Dismantling Of Ceiling Fan And Painting The Same With With One Or More Coats Of Spray Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade, Including Cleaning Of Surface With Detergent And Replacing The Damaged Rubber Reel, Nuts And Bolts With Washers And Safety Pins Reinstalling The Same As Required. 91 Od276779 / 2023_2024 : Supply And Fixing Of Fire Retardent / Extinguishing Electric Insulated Synthetic Mat Of Standard Size Minimum 2 Mm Thick For 3.3Kv Grade As Directed By Engineer In Charge 92 Dismantling Works 93 Od274140 / 2023_2024 : Charges For Dismantling Existing Wiring Of Light / Fan / Bell / Points Without Switch Boards Such As Pvc Conduits, Wire, Earthing Conductor, Circuit Mains, Etc Without Damages And The Samestocked At Electrical;L Store Room Near The Site.& Collected Hand Receipt 94 Od280539 / 2023_2024 : Charges For Dismantling Existing Ceiling / Wall / Exhaust Fan And Fittings Of All Sizeswith All Accessories Without Damages And Stocked At Electrical Store Room Near The Site & Collected Hand Receipt As Per Direction Of The Engineer Incharge. 95 Od274214 / 2023_2024 : Charges For Dismantling Of Existing Pre-Wired Ordinary 40 W Flurecent Tube Light Fittings Made Of .5Mm Thick Crca Sheet Accessories And Lamps ( Tube Set And Accessories Excluding Ball& Down Rod ) With Out Damage And Stocked At Electrical Store In Consultation With Ae / Aee Electrical Kshb , Also The Same Recorded In Handing Over Register As Per Direction From Kshb Engineer In Charge 96 Od274705 / 2023_2024 : Charges For Dismantling Existing Ac With Stabilizer, Stat, Copper Pipe Etc Without Damages And The Samestocked At Electrical & Collected Hand Receipt Store Room Near The Site.
97 Od274723 / 2023_2024 : Charges For Dismantling Existing Angle / Ceiling / Wall Light Fittings With All Accessories Without Damages And Stocked At Electrical Store Room Near The Site & Collected Hand Receipt
98 Conference Hall ( Rt-Eklm ) 99 Od273576 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Usb Ptz Full Hd Video Conferencing Camera , Full Hd Video Conferencing Camera - 10X Optical Zoom As Per Direction Of Engineer In Charge. ( Makea&T Klick U1 Sb Ptz Or Equivalent 100 Od273577 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Floor Mount Trolley Stand 65, 75 - Custom
Floor Mount Trolley Stand Size 65, 75 As Per Direction Of Engineer In Charge 101 Od273578 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Interactive Flat Panel Display Features Enhanced , Wi-Fi 6, Broad Compatibility, 65W Powered Usb Type-C, High Quality Sound System, Antimicrobial, Surface Secure, User Profiles, Android 11 Active Screen Size ( Inch ) : 65, Display Backlight : Led, Resolution : 3840 X 2160 ( 4K ) , Lcd Brightness : 400 Cd / M2, Life Time : >50000 Hrs, Touch Surface Material :Toughened Tempered Glass, Touch Surface Technology : Anti-Glare Glass , Touch Surface Hardness : H7, Touch Points : 20 Points, Touch Screen, Response Time : 6Ms, Viewing Angle : 178°, Android Version: 11, Ram : 4Gb, Rom : 64 Gb, Speaker Max. Power Output : 15 W X 2 Speakers Including Accessories : Wall Mount Kit, Remote, Hdmi, Power & Usb Cables. Warranty : 3 Years Onsite Warranty + 2Yr Amc ( Make: Newline Or Equivalent. ) .
Including,
Ups - 1Kva Ups With Inbuilt Battery,
Ups Cabinet - Wall Mount Metal Cabinet For 1 Kva Ups,
Floor Mount Trolly Stand - Heavy Duty,
Wireless Mouse & Keyboard As Per Direction Of Engineer In Charge 102 Od275030 / 2023_2024 : Supply, Ofwi Fi Modem Supported In To The Existing Land Linetelephone System Standard Make & Model ( D Link Dsl -2750 U Or Equivalent Model ) As Per Direction Of Engineer In Charge 103 Od275081 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Portable Usb & Bluetooth Conference Phone , “Plug-And-Play” Connectivity With Driver-Less Usb, Bluetooth, Nfc And Audio In / Out Connection Interfaces As Per Direction Of Engineer In Charge ( Make:Yamaha Yvc-330 High-Performance Unidirectional Microphones Or Equivalent ) 104 1.53.1 : Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable
Contract Date: Feb 05, 2024 Contract Value : 18.23 Lakh
Government Departments No of Bidders 2
19.
Public Administrative Department #3210506 AOC
Providing Electrical Material , Erecting Electrical Work And Repairing Of Electrical Equipment Of Municipal Council Chalisgaon For Fy 2023-24-2 Supplying 1.5 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 3 Supplying 2.5 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 4 Supplying 4 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 5 Supplying 6 Sq Mm Service Wire Per ( 2Core ) 90 Mtr 6 Supplying 10 Sq Mm Service Wire ( 2Core ) 90 Mtr 7 Supplying Mains With 2X1.5 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wgma / Bw 8 Supplyin Mains With 2X2.5 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wgma / Bw 9 Supplying Pvc Insulated Pvc Round Sheathed 4 Sq.Mm ( 56 No. X 0.30 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv 10 Supplying 6 To 32 A Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. 11 Supplying 40A To 63A Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. 12 Providing & Erecting 3 Pole Mccb Upto 100A, 415V, With Short Circuit Rating 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure On Iron / Gi Frame As Per Specification No. Sw-Swr / Mccb 13 Supplying Led 18W Tube Light Fitting ( 4 Feet ) With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver Complete 14 Supplying Fuse Bridges With Base Hc Type Fuse Links 240V 63A Erected On Polished Wooden Block Complete 15 Supplying 4 Pole Power Contactor 63 A With Coil Voltage Of 220 / 240 V 16 Supplying 4 Pole Power Contactor 80A-130A With Coil Voltage Of 220 / 240 V 17 Supplying Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Upto 16A To Use Independently Or In Conjunction With Contactor. 18 Supplying 12 V / 150Ah Tubular Battery With Battery Terminal Wire, Duly Charged Complete With 36 Months Warranty Complete 19 Supplying & Erecting 12 V 88 Ah Heavy Duty Plate Type Battery With Terminal Wire Duly Charged Complete Suitable For Dg Set With Warrantee For 3 Years 20 Supplying Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 21 Providing Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. 22 Supplying Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 300Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected In An Approved Manner. 23 Supplying 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 24 Mode Of Work - Supplying, Erecting And Comissioning Part Only 25 Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14 / 16 Swg Sheet, Outdoor Type, Three Phase, 415V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Tpn Mcb 63 A Auto / Manual Selector Switch, On / Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / Cc Foundation Complete. 26 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 27 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 28 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 29 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 30 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 31 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 32 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 33 Supplying & Erecting G.I. Pipe ‘A’ Class 40 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall / Pole As Per Specification No. Cb-Ce ( As Per Csr 21-22 7-6-2 ) 34 Supplying And Erecting Architectural Pole Of 4Mtr Height, Pole Placed With A Aluminium / Cast Iron Embellishment On The Bottom & Middle Section For Aesthetic & Decorative Purpose, Pole Shall Have Aluminium / Cast Iron Casting On The Base Middle And On The Joint Giving It Decorative Look, The Base Aluminium / Cast Iron Casting Shall 148Od With A Height 180Mm The Casting Will Have Ring On The Top 20Mm Thickness, The Middle Al / Cast Iron Casting Shall Be Of Conical Design With Bottom Section Of 145 Od Having 3 Ring Of 15Mm Each. The Conical Casting Shall Taper For 145 Od On Bottom To 92Mm On Top , The Pole With Inbuilt Junction Box To Fix 32 Amp Connectors & 6 Amp Mcb Inside Cut Window Of The Bottom Pipe With Suitable Size ( As Per Attached Drawing ) ( Non Dsr Item ) 35 Supplying And Erecting Attractive / Decorative Type Of Bracket With Reducer / Expander For Holding Decorative Fixture On Provided Main Pole Having All The Arrangement Perpendicular To Ground , The Bracket Type Is The Double Arm Shall Have Span With 1000Mm With In The Middle Made Of 8 Mm Rod With Flower Leaf Design ( As Per Attached Drawing ) ( Non Dsr Item ) 36 Supplying And Erecting Attractive / Decorative Type Of Bracket With Reducer / Expander For Holding Decorative Fixture On Provided Main Pole Having All The Arrangement Perpendicular To Ground , The Bracket Type Is The Single Arm Shall Have Span With In The Middle Made Of 8 Mm Rod With Flower Leaf Design ( As Per Attached Drawing ) ( Non Dsr Item ) 37 Supplying And Erecting Of Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management ( Pdchm ) And The Ip Optical Compartment With High Power Led Is Comprised Of Deep Drawn Chemically Polished And Co-Extruded Thransformed Polycarbonate Protector Stabilzed Agent Uv Rays Suitable For 40-60 W Led Fitting Should Be Hangging Type Mounting Decorative Fixture With Inbuilt Driver With Efficiency >0.9 And Having Surge Protection Device Of 10 Kva Colour Temperature 3000K / 4000K / 5700K Natural Day Light Led, Led To Be Osaram / Cree / Bridgelux & Driver To Be Make With Philips / Fulham / Osaram ( As Per Attached Drawing ) ( Non Dsr Item ) 38 Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T / Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 6M To 8M High Octagonal / Conical Gi Pole ) . ( As Per Csr 21-22 16-3-9 ) 39 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete ( As Per Csr 21-22 7-6-9 ) . 40 Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep ( As Per Csr 21-22 9-1-4 ) 41 Supplying And Erecting Led Square / Circular 5 To 8W Down Lighter Having Pressure Die-Cast Aluminium Housing, Opal Translucent Cover, Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips For Flush Type Complete. 42 Supplying Led Concealed Type Foot / Step Light With Aluminium Body For Indoor / Outdoor Application Suitable For Upto 4W-6W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface. 43 Supplying Led Up Down Light With Aluminium Body For Indoor / Outdoor Application Suitable For Upto 4W-6W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface. 44 Supplying And Erecting Led Flexible Strip Light 5M Length Upto 25W Conforming Ip 65 Of Any Colour With Driver Complete. 45 Supplying And Erecting Gi Strip Of Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint In An Approved Manner With Joints Required. As Per Specification No Ea-Ep. 46 Mode Of Work - Repairing Works Only 47 Rewinding Motor Of The 1200 / 1400 Mm Ceiling Fan And Over Hauling Including Minor Repairs Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. Testing Of Fan For Original Speed And Consumption With Guarantee For One Year. 48 Repairing Of Generator Focus Lamp With Chock, Connector Coil Etc 49 Servising Of Generator Focus Lamp 50 Mode Of Work - Repairing And Providing Municipal Council Ac Units 51 Providing Servicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Air Conditioning Unit Complete With All Necessary Material. Job Includes Checking Of Performance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unit With Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unit And Submitting Report To Engineer Incharge. 52 Providing Flushing Out Cooling Coil And Condensor Coil Of Airconditioner Unit Refrigerant Pipes Internally With Dry Nitrogen Pressure In An Approved Manner 53 Providing Brazing Pipes And Checking Leakages In The Split / Window Unit Duly With Dry Nitrogen Pressure In An Approved Manner. 54 Providing Replacement Of Existing Unservicable Rotary / Scroll Compressor Of Air Conditioner 1.5 Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 55 Providing Replacement Of Existing Unservicable Rotary / Scroll Compressor Of Air Conditioner 3 Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 56 Providing Replacement Of Unserviceable Starting Relay For Ac Unit. 57 Providing Replacement Of Unserviceable Starting / Running Capacitor For A / C Unit. 58 Providing Replacement Of Unserviceable Fan Motor Capacitor For A / C Unit. 59 Providing Replacement Of Unserviceable Pcb For A / C Unit Upto 3 Tr Capacity. 60 Providing Repair Of Of Faulty Pcb For Air Conditioning Unit Upto 3 Tr Capacity. 61 Supplying And Installing Of New Fan Motor For Condenser For Air Conditioning Unit 62 Supplying And Installing Of New Fan Motor For Indoor Unit Of Air Conditioner Up To 3 Tr Suitable To Operate On 230V To 250V Ac Or 280V To 340V Dc Supply Having 4 To 8 Poles As Per Requirement. 63 Supplying And Installing New Fan Blade Outdoor Unit For Air Conditioning Unit. 64 Providing Replacement Of Blower Of Indoor Unit For Air Conditioning Unit. 65 Providing Replacement Of Remote Of Indoor Unit For Air Conditioning Unit. 66 Providing And Fixing Indoor Plastic Cabinet With All Accessories 67 Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R-22 Refrigerant For 1.5Tr Window / Split Air Conditioning Unit. 68 Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R-22 Refrigerant For 3Tr Window / Split Air Conditioning Unit. 69 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 70 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 71 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor. Room Air Conditioning Unit 1.7Tr To 2.0Tr Capacity Having Iseer Minimum 5.0 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position In Provided Recess With Wooden Frame Complete Specification No. Ap-Ac / Wac 72 Supplying, Installing, Testing & Commissioning Cassette Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor Room Air Conditioning Unit 2.5Tr To 2.7Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 / R410a Having Copper Condenser, Dust Filter, Self Diagnosis Feature, Stabilizer Free Operation, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 73 Supplying, Installing, Testing & Commissioning Cassette Type Room Air Conditioning Unit 3.4Tr To 3.9Tr Capacity With Refrigerant R32 / 410A 415V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit ( Mega Split ) Mounting Type Complete With Temperature Display On Indoor Unit, Minimum Dust Filter, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 74 Supplying, Installing, Testing & Commissioning Cassette Type Room Air Conditioning Unit 4Tr To 4.4Tr Capacity With Refrigerant R32 / 410A 415V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit ( Mega Split ) Mounting Type Complete With Temperature Display On Indoor Unit, Minimum Dust Filter, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 75 Mode Of Work - Electrical Fitting Part Only 76 Supplying And Erecting Pvc Trunking ( Pvc Casing-Ncapping ) Of Size 32 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 77 Supplying And Erecting Upvc Reinforced Flexible Conduit 31 / 32 Mm In Dia. Conforming To I.S. With Required Number Of Couplings, Pvc Bushes, Check Nuts Etc. Complete. 78 Supplying And Erecting Hms Pvc Conduit 32 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 79 Point Wiring For Independent Plug In 20 Mm Isi Marked Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Fr Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 80 Wiring For Plug On Board With Switch Socket, Copper Wiring And Earthing As Per Specification No: Wg-Pw / Sw 81 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 82 Point Wiring In Pvc Trunking ( Casing-Capping ) With 1.5Sq.Mm ( 2+1E ) Fr Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wgpw / Sw 83 Secondary Point Wiring For Additional Light / Bell Point In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Fr / Frlsh Grade Copper Wire With Required Accessories As Per Specification No: Wg-Pw / Sw 84 Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendent Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block / Pvc Junction Box. 85 Supplying And Erecting Isi Mark Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 86 Supplying And Erecting Flush Type Shockproof Plug Socket 6A & 16A ( 6 Pin ) With 16A Switch Combined With Indicator Lamp And Fuse With Gang Box On Wooden Board. 87 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected. 88 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 13Modules Duly Erected. 89 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 18 Modules Duly Erected. 90 Mode Of Work - Repairing And Providing Led Lights Only 91 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 92 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 93 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 46W-75W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 94 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 76W-100W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 95 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 101W-150W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 96 Repairing For 18 To 45 W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 97 Repairing For 50 To 75 W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 98 Repairing For76 W To 100Wled Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 99 Repairing For76 W To 150W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 100 Repairing For 100 To 120 W Flood Light Plate With Al Required Accessories 101 Providing For 100 To 120 W Flood Light Plate With Al Required Accessories 102 Providing For 18W To 45 W Flood Light Plate With Al Required Accessories 103 Providing For 46W To 75 W Flood Light Plate With Al Required Accessories 104 Providing For 76W To 90 W Flood Light Plate With Al Required Accessories 105 Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 106 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 107 Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 108 Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140 270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 109 Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Classg.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification No. Fg-Bkt / Bpc 110 Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3Years Warranty As Per Specification No Fg-Odf / Fls2. 111 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 112 Mode Of Work - Shifting Of Highmast / Rsj / Round Pole 113 Dismentaling And Erecting Upto 20 M ( Clear Height ) Motorized / Non Motorized High-Mast On Provided Foundation With Carefully Dismentallation And Erection Of Wire, Luminaries Etc Complete 114 Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T / Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( Upto 20 M Raising Lowering High Mast ) . 115 Providing Wire Rope For Raising Lowering High Mast 116 Providing Luminaries Ring For Raising And Lowering High Mast 117 Supplying And Erecting Rolled Steel Joist ( Girder ) Pole 125 X 70 Mm ( 13.3 Kg / M ) With Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Rsj ( For 8 Mtr ) 118 Supplying And Erecting G.I. Pipe Pole ‘B’ Class 80 Mm Dia 6 M Long With Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Gip 119 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 Length Along With Street Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Complete As Per Specification No Cw -Ptg / Ptp. 120 Supplying And Erecting 3 Phase 4 Core 50 Sq.Mm. ( 3X50+1X35 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 121 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 122 Supplying And Erecting 3 Phase 4 Core 70 Sq.Mm. ( 3X70+1X50 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 123 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) 124 Making Cement Concrete Foundation In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm. Stone Metal Duly Plastered With Necessary Curing For Complete. ( Pole Muffing Or Any Other Purpose ) . 125 Mode Of Work - Extra-Other Accessories 126 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc 127 Supplying And Erecting Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Kwh, Kvah, V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva ) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 128 Supplying And Erecting Static Energy Meter With 3 X 240V 50 Hz. Ac Supply 10 To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Trivector, V, I, Kw, Pf, Hz, Last Month History Of Kwh And Md In Kw ) With Special Features Like Tod, Tamper Logging, Optical Communication Port & Display In Absence Of Power & With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 129 Government Of Maharashtra Public Works Department ( Electrical Wing ) Current Schedule Of Rates For 2021-2022 ( Note :- Use Of This Item In Critical Condition For Detail Refer Dtn )
Contract Date: May 12, 2023 Contract Value : 11.71 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
21.
Public Administrative Department #2783126 AOC
Renovation Of Extg Fountain And Preparation Of National Clean Air Programme In Amc Sector . , Desilting The Sum Of Sewerage Works In Wet Or Dry Condition Including Lifts 0 To 9 . 00 Mt & Lead Upto 150 M As Required Beyond The Work Site , Stacking Spreading , Including Necessary Guarding Etc . Complete , As Directed By The Engineer - In - Charge . ( As PerNo , Conveying Materials Obtained From Road Cutting Including All Lifts , Laying In Layers Of20Cm To 30Cm . Breaking Clods , Dressing To The Required Lines , Curves , Grades And Section , Watering And Compacting To Not Less Than 97% Of Standard Proctor Density For A Lead Of Over50M . To 300M . Inclusive From The Site Of Excavation To The Site Of Deposition As Directed . , Removing Cement Or Lime Plaster Including Disposing Of The Spoils As Directed With All Leads , Lifts Etc , Complete . , Removing Cement Tiles , /Tiles Or Marble Or Polished Shahabad Floor Or Dado Without Bed Concrete Including Stacking The Materials As Directed With All Leads , Lifts Etc . Complete , Providing Cement Based Water Proofing Treatment To Terraces ( Indian Water Proofing Or Alike ) With Brick Bats Laid In Required Slope To Drain The Water For Any Span After Cleaning The Base Surface . Applying A Coat Of Cement Slurry Admixed With Approved Water Proofing Compound And Laying The Brick Bats On Bottom Layer In C . M . 1:5 Admixed With Approved Water Proofing Compound Filling Up To Half Depth Of Brick Bats , Curing This Layer For 3 Days , Applying Cement Slurry Over This Brick Bats With C . M . 1:3 Admixed With Approved Water Proofing Compound And Finally Top Finishing With Average 20 Mm . Thick Layers Of Same Mortar Added With Jute Fiber At 1 Kg Per Bag Including Finishing The Surface Smooth With Cement Slurry Admixed With Approved Water Proofing Compound . Marking Finished Surface With False Squares Of 300Mm X 300 Mm . Making The Junctions At The Parapet Rounded And Tapered Top For Required Height , With Drip Mould At The Junction Of Plaster And Parapet And Curing And Covering 10 Years Guarantee Against Leakproofness On Court Fee Stamp Paper Of Rs . 500/- Including Ponding Test Etc . Complete . , Providing And Applying Water Proofing Treatment Using Acrylic Polymer Modified Cement Based Water Proofing Coating With Fibre Glass Mesh Mixing At The Rate Of Powder To Liquid ( 2:1 ) By Weight Covering 9 To 10 Sqm/Kg With Two Coat Using Dr . Fixit Or Alike Of Chemicals For Masonry And Concrete Surface By Brush Covering 7 Years Guarantee On Stamp Papers Etc . Complete . , Providing And Laying Cast In Situ/Ready Mix Cement Concrete In M20 Of Trap/ Granite/Quartzite/Gneiss Metal For Bed Blocks , Foundation Blocks And Such Other Items Including Bailing Out Water , Plywood/Steel Formwork , Laying/ Pumping , Compacting , Roughening Them If Special Finish Is To Be Provided , Finishing Uneven And Honeycombed Surface And Curing Etc . Complete . The Cement Mortar 1:3 Plaster Is Considered For Rendering Uneven And Honeycombed Surface Only . Newly Laid Concrete Shall Be Covered By Gunny Bag , Plastic , Tarpaulin Etc . ( Wooden Centering Will Not Be Allowed . ) , With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer/ Concrete Batch Mix Plant ( Pan Mixer ) Etc . Complete . With Natural Sand/V . S . I . Quality Artificial Sand , Providing Second Class Burnt Brick Masonry With Conventional/ I . S . Type Bricks In Cement Mortar 1:6 In Foundations And Plinth Of Inner Walls/ In Plinth External Walls Including Bailing Out Water Manually , Striking Joints On Unexposed Faces , Raking Out Joints On Exposed Faces And Watering Etc . Complete . , Providing Internal Cement Plaster 20Mm Thick In Two Coats In Cement Mortar 1:4 Without Neeru Finish , To Concrete , Brick Surface , In All Positions Including Scaffolding And Curing Etc . Complete . , Providing Sand Faced Plaster Externally In Cement Mortar Using Approved Screened Sand , In All Positions Including Base Coat Of 15 Mm Thick In Cement Mortar 1:4 Using Waterproofing Compound At 1 Kg Per Cement Bag Curing The Same For Not Less Than 2 Days And Keeping The Surface Of The Base Coat Rough To Receive The Sand Faced Treatment 6 To 8 Mm Thick In Cement Mortar 1:4 Finishing The Surface By Taking Out Grains And Curing For Fourteen Days Scaffolding Etc . Complete . , Providing And Fixing Mild Steel Grill Work For Windows , Ventilators Etc . 20 Kg/Sqm As Per Drawing Including Fixtures , Necessary Welding And Painting With One Coats Of Anticorrosive Paint And Two Coats Of Oil Painting Complete . , Providing And Laying Cast In Situ/Ready Mix Cement Concrete In M15 Of Trap/ Granite/Quartzite/Gneiss Metal For Bed Blocks , Foundation Blocks And Such Other Items Including Bailing Out Water , Plywood/Steel Formwork , Laying/ Pumping , Compacting , Roughening Them If Special Finish Is To Be Provided , Finishing Uneven And Honeycombed Surface And Curing Etc . Complete . The Cement Mortar 1:3 Plaster Is Considered For Rendering Uneven And Honeycombed Surface Only . Newly Laid Concrete Shall Be Covered By Gunny Bag , Plastic , Tarpaulin Etc . ( Wooden Centering Will Not Be Allowed . ) , With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer , Providing And Laying Rough Shahabad Stone Flooring 50Mm To 60Mm Thick And Of Required Width In Plain/ Diamond Pattern On A Bed Of1:6 C . M . Including Cement Float , Striking Joints , Pointing In Cement Mortar 1:3 Curing And Cleaning Etc . Etc . Complete , Providing And Laying Ceramic Tiles Of Having Size 30 Cm X 30 Cm Confirming To I . S . 15622/2006 ( Group D Ii-A ) And 7 To 8 Mm Thick For Flooring In Required Position Laid On A Bed Of 1:4 Cement Mortar Including Cement Float , Filling Joint With White/Colour Cement Slurry Cleaning Curing Etc . Complete . , Providing And Laying Ceramic Tiles Of Having Size 30 Cm . X 30 Cm . And Confirming To Corresponding I . S . For Dado And Skirting In Required Position With Readymade Adhesive Mortar Of Approved Quality On Plaster Of 1:2 Cement Mortar Including Joint Filling With White/ Colour Cement Slurry Cleaning Curing Etc . Complete . , Providing And Erecting Chain Link Fencing 1 . 6M . Height With G . I . Chain Link Of Size 50 X 50 Mm , 8 Gauge Thick And Fixed 75 Mm Above Ground Level On Vertical M . S . Angles Of 40 X 40 X 6 Mm Size , Includind Excavating Pits For Foundation And Embedded In C . C . Block Of1:4:8 Mix Of Size 450 X 450 X 670 Mm . At1 . 75 M . C/C With Iron Bar 16Mm Dia As Hold Fast Including Welding Link With Angle Frame At30 Cm C/C With Nuts And Bolts And Horizontal M . S . Angles At Top And Bottom Of 25 X 25 X 5 Mm Size And Vertical M . S . Flat 35 X 5 Mm And25 X 5 Mm Horizontal Including Cross Support Of 40 X 40 X 6 Mm Angles Both Side At Every Corner Or Bend Embedded In Concrete Blocks Of1:4:8 Of Size 450 X 450 X 670 Mm , Providing And Fixing On Walls/ Ceiling/ Floors , 50 Mm Dia Heavy Grade Having Embossed AsIsi Mark Galvanised Iron Pipes Weight Of 6 . 33Kg/Meter With Necessary Fittings . And Remaking Good The Demolished Portion And Primer Of Anti Corrossive Oil Paint 2 Coats Including Necessary Scaffoldi
Contract Date: Jul 29, 2020 Contract Value : 9.95 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
22.
Educational and Research Institute #2302087 AOC
Purchase Of Instruments Equipments-Plc Control Based Flameproof Laboratory Refrigerator Control System Ce, Iso And Gmp Approved Flame Proof Temperature Controller With Auto Tune Plc Based Control System. Individual Control System Easy To Install On Suitable Space Software Provision For Future Requirement Machine Should Have A Provision Of Cfr 21 Part 11 Compliance Windows Based Communication Software For Data Management. Complete With Rs-485 Multi Dropping To Monitor Multiple Chambers To One Software In Future ( If Required ) Future Data Logger Provision For Master Controller Data Storage Unit In Future ( If Required ) Air Circulation Motor And Blower Arrangement To Have Uniformity Of Under Loaded Condition. Alarm :Temperature Deviation Alarm Trays: Stainless Steel Trays With Adjustable Height Florescent Light: Cool White Florescent Light Auto On When Door Open Insulation :75” Thick Cfc Free Puf Insulation. Door: Inside See Through Unbreakable Acrylic Door Sub Door: Sub Doors Made Of Acrylic / Glass Door Refrigeration System Hermetically Sealed Cfc Free Emerson Compressor With R 134A Refrigerant Having State Of Art By Pass System For Continues Run Of Compressor. Power:Works On 230 V Ac Single Phase 50Hz Other Castor Wheels, Mcb, Adjustable Tray Height Arrangements. Heavy Duty Latch With Lock & Key Safety Features :180 Sec. Compressor ‘On’ Delay Timer To Safe Guard The Compressor. Documentations Should Provide Iq, Oq, Pq Documents With Material Test Certificates And Calibration Reportsspecifications Temperature Range 2 To 8°C Temperature Accuracy ± 0.5° C Temperature Uniformity 2° C Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Outer Stainless Steel 304 Capacity In Ltr.: 420 Internal & In Cms ( W X D X H ) : 70X50x120 Outer Size In Cms ( W X D Xh ) : 85X75x170 No. Of Trays: 4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Specifications Temperature Range 2 To 8°C Temperature Accuracy ± 0.5° C Temperature Uniformity 2° C Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Outer Stainless Steel 304 Capacity In Ltr.: 420 Internal & In Cms ( W X D X H ) : 70X50x120 Outer Size In Cms ( W X D Xh ) : 85X75x170 No. Of Trays: 4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Plc Control Based Flameproof Deep Freezer Control System Ce, Iso And Gmp Approved Flame Proof Temperature Controller With Auto Tune Plc Based Control System. Individual Control System Easy To Install On Suitable Space Software Provision For Future Requirement Machine Should Have A Provision Of Cfr 21 Part 11 Compliance Windows Based Communication Software For Data Management. Complete With Rs-485 Multi Dropping To Monitor Multiple Chambers To One Software In Future ( If Required ) Future Data Logger Provision Master Controller Data Storage Unit In Future ( If Required ) Display Lcd Display Sensors Pt 100 Sensor Alarm 1. Temperature Deviation Alarm 2. Audio Alarm For High And Low Temperature Trays Stainless Steel Trays With Adjustable Height Insulation Polyurethane Insulation 75Mm Thick Cfc Free Puf Insulation. Refrigeration System Flame Proof Hermetically Sealed Cfc Free Emerson Compressor With R 134A Refrigerant Having State Of Art By Pass System For Continues Run Of Compressor. Specifications Temperature Range -30°C Or Less Temperature Accuracy ± 1° C Temperature Uniformity 5° C Resolution 0.1° Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Stainless Steel, 304, 1.0 Mm Capacity In Ltr. :189 Internal Size ( W X D X H ) Cms: 35X45x120 Outer Size ( W X D X H ) Cms : 50X60x170 No. Of Doors : 1 No. Of Trays :4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Weighing Capacity : Up To 220Gms Readability: 0.1Mg, Repeatability 1 Mg Or Less Linearity: + / - 0.2Mg Reproducibility: < / = 0.1Mg Std Deviation : <+0.1Mg Pan : 80Mm Or More Verifiability: Capable Of Ec / Oimc Certification Calibration: Use 100Gm + / -0.1Mg Display: Led / Lcd Backlit Draft Shields: Glass Shield Function: Inter Counting , Percent Weighing, Weighing Read Out In Most Common International Units Leveling: Manual Adjustments: Internal Iso Calibration Printer With Statistical Option Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty For The Full Consignment Supplied From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. 1. Weighing Capacity: Up To 600 G 2. Readability: 0.1Mg , Repeatability 1 Mg Or Less. 3. Linearity: + Or – 0.2 Mg. 4. Reproducibility: <= 0.1 Mg 5. Std. Dev : < +0.1Mg 6. Pan: 80Mm Or More. 7. Verifiability: Capable Of Ec / Oimc Certification. 8. Calibration: Use 100 Gm + / - 0.1 Mg. 9. Display: Led / Lcd Backlit. 10. Draft Shields: Glass Shield. 11 Function: Inter Counting, Percent Weighing, Weighing Read Out In Most Common International Units. 12 Leveling: Manual 13 Adjustments: Internal Iso Calibration Printer With Statistical Option Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty For The Full Consignment Supplied From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Digital Zone Reader Suitable To Measure The Diameter Of Inhibited Zone To 0.1Mm Within The Range Of 0 To 80.0Mm. Least Count 0.1Mm Resolution 0.1Mm Electronic Zero Adjustment Fine Focus Adjustment For Clear Image On The Viewing Glass. No Effect Of Ambient Light On Image. Halogen Light For Sharp & Bright Optical Imaging. Light Should Pass Through Transparent And Semitransparent Portion Of Agar And The Magnified Image Of The Zone Of Inhibition Can Be Clearly Seen On The Prism. Adjustable Belt To Facilitate Positioning Of The Dish Relative To Light Source. The Instrument Is Supplied Complete With All The Required Accessories Like Prism, Bulbs Etc. Power Required : 230V Ac ; 50Hz Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors 5 Point Calibration With Lcd Display With Printer Combined Glass Ph Electrode ( 0 To 14 Ph Accuracy + 0.02 ) Rtd For Temperature Sensing ( 0 To 99°C ) And With Printer Power Supply:100 – 300 V Ac; 47 To 63Hz Spare: Flat Surface Electrode Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors A System Complete With Illumination System Is Required For View Of Individual Cells, Even Living Ones With High Magnification Microscope Using 2 Eye Lenses To Reduce The Eyestrain. Body: • Body-Single Mold Sturdy Stable Base Stand, Inclined Binocular Body 30 Deg. 360 Deg. Rotatable Head With Focus Adjustment Controls. • A Durable Textured Acid Resistant Finish • All Optical Parts Including Objectives, Eye Pieces And Prisms Should Have Anti-Reflective Coating Which Also Gives Anti-Fungal Property. • All Metallic Parts Should Be Corrosion – Proof; Acid Proof And Stain-Proof. Eye Piece • -Highest Quality 10 X / 20Mm Wide Angle Anti Fungus Field Eye Pieces. One With Pointer. Diopter Adjustment Must Be Present On Both Eye Pieces. ( The Image Of The Object As Seen Through The Binocular Eyepiece Should Be Well Defined Centrally In At Least 2 / 3 Field Of View ) . • Achromatic, Wide Field, 10 Z With Inbuilt Pointer. • The Eyepiece Should Be Aplanatic And Have A Minimum Field Number Of 18 Diopter Adjustment Must Be Present On One / Both Eye Pieces Or On The Eye Piece Tube. Optical System • Optical System Should Be Infinity Corrected. • Built-In Led Light Source With White Light With Intensity Control And Led Life Of More Than 10, 000 Hrs. Objective • Parfocal, Antifungal Coated 4 X, 10X, 40X And 100X ( Oil Immersion ) With Semi Planner Achromatic Correction. • Objective Should Be Well Centered Even If Their Position On Turret Is Changed. • 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively. • 100Xshould Have Numerical Aperture Of 1.25 And Should Be Of Oil Immersion. • Unbreakable Containers To Be Provided For Storing The Objectives. • All Objectives Should Be Wide Field, Achromatic And Par Focal. Nose Piece • Backward Tilted Revolving Nose Piece Suitable To Accommodate Four Objectives With Click Stop • It Should Be Provided With Rubber Ribbed Grip For Easy Rotation Mounted On A Precision Ball Bearing Mechanism For Smooth And Accurate Alignment. Extra Ports If Any Should Be Fitted With Dust And Fungal Proof Metallic / Ebonite Caps. Focusing: • Coaxial Coarse And Fine Focusing Knob, Capable Of Smooth, Fine Focusing Movement Sensitivity; Minimum: 300 Micron; Focusing Stop For Slide Safety. Stage • Stage Uniformly Horizontal, Mechanical Stage Having Dimensions Of Length 140 Mm ( + / - 20Mm ) With Fine Vernier Graduations ( Minimum Reading Accuracy Of 0.1 Mm ) . • It Should Be Designed With Convenient Sub-Stage Vertical Coaxial Adjustment For Slide Manipulation. • The Stage Should Have Ball-Bearing Arrangement To Allow Smooth Travel In Transverse Directions I.E. 80 Mm ( + / - 5Mm ) And Front To Back Direction, 50Mm ( + / -5Mm ) . Sub-Stage Condenser • Abbe-Type Condenser With Numerical Aperture ( N.A. ) 1.25 Focusable With Rack And Pinion Arrangement Incorporating A Spherical Lens And An Iris-Diaphragm. Sub-Stage Illuminator • The System Should Have A Build-In Variable Light Source ( Illuminator ) . • This Light Source Should Have A 20 W, 6 V Halogen Lamps. • The System Should Have A Build –In Variable Light Source ( Illuminator ) . • This Light Source Should Have A 20 W, 6 V Halogen Lamps. • The System Should Be Provided With A Step Down Transformer And An On-Off Switch And Intensity Control. • The Lamp Should Be Provided With A Lamp Socket Which Has The Facility For Easy Replacement Of The Bulb Power Supply & Protection • Voltage 220 V Ac, 50 Hz. Should Have One On-Off Power Switch. • A Plano-Concave Mirror In Fork Mounting Should Be Supplied Which Would Be Attachable To The Base For Field Use When Power Is Not Available. • Should Have Over-Charging Cut-Off With Visual Symbol. Battery Backup • Minimum 1 Hour Operating And Storage Conditions • Capable Of Operating Continuously In Ambient Temperature Of 10 To 50 Deg. C And Relative Humidity Of 15 To 90% In Ideal Circumstances. • Storage Condition: Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg. C And Relative Humidity Of 15 To 90%. Manual Accessories • Working Manual Should Be Provided With Each Microscope. • Immersion Oil 25 Ml X 2 • Lens Tissue Paper 2 Rolls Or Boxes • Lens Cleaning Solution ( 100Ml ) • One Anti-Static Cleaning Brush. • The Unit Shall Be Capable Of Being Temperature Of 0 – 50 Deg. C And Relative Humidity Of 15-90%. Note: - Free Of Cost Installation, Demo And Training To Be Provided On Site • Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period • All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors Operating Frequency 33+ / -3 Khz, For All General Purpose Cleaning Is Highly Recommended. Input Voltage: Range Of 170V Ac-270V Ac, 50Hz, Iph. Micro Controller Based Timer Range: 0 To 30 / 99 Minutes Thermostatic Controlled Temperature Controller. Capacity: 3.5 Lit. Tank Size: ( Lxbxh ) Mm 300X150x100 Over All Dimension ( Lxbxh ) Mm 330X175x250 Wattage : 120W Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Capacity: 5 Liters With Easy Cleaning Facility Material Of Construction: Body Should Be Compact, Durable, Leak Proof Ad Made Of Stainless Steel / Heavy Duty Plastic Particle Size: • It Should Produce Aerosols With Particle Size Of Less Than 5 Microns • The Blower Head Should Be Rust Proof Inert To Formaldehyde, Kmn04, H2o2 And Deliver Aerosols Uniformly. Unit • It Should Be Compatible With All Disinfectant Solutions Usual Concentration. • It Should Be Compatible With Maximum Ph Range ( Both Acid And Alkali ) . • The Equipment Should Be Of Good Quality And Conform To National / International Standards. Power Supply The Machine Should Operate On 220+ / - 10 Volts, 50 Hz, Single Phase, A.C Provided With Cable Should Be At Least 5 Meters In Length, Isi Marked. Operation The Discharge Rate Should Not Be Less Than 1 Liter / 25 Minutes. The Tank Capacity, Discharge Rate And Timer On The Machine Should Be So That The Disinfectant Should Be Able To Disinfect 4000-5000 Cubic Feet In One Cycle Of 2 Hours ( Max ) . Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors• Material: Abs Plastic. Specifications Of Steam Pot  The Special Digestor Should Be Designed To Use For Bulk Media Digestion At 100ºc / Boiling Water Temperature & Also Other General Purpose In Microbiology Lab.  The Rectangular Bath Should Have Chamber Size In Such A Way That, It Can Accommodate 6 Nos Erlenmeyer Flask Of 2000 Ml Or 6 Nos Duran Bottles Of Capacity 5000 Ml.  It Should Have Volume Of Around Aprox 80 -100 Ltr. Media Digestor Should Be Provided With Stainless Steel Stand. It Should Have Full Stainless Steel Ss304 Double Walled Construction With Thickness Of Minimum 1Mm & Insulation For Preventing Energy Losses. Lid Should Be Made Of Ss304 & Should Have Assisted Lift For Easy Opening As Well As Effortless Loading & Removal Of Flasks. It Should Have Easy To Operate Lid Latching Design Fitted On Flat Insulated Double Wall Lid. Lid Latching Handle Should Be Made Of Stainless Steel And Suitably Coated With Cool To Touch Sleeve. Drip Tray Should Be Provided Below The Lid Inside Chamber To Avoid Dripping Of Condensate On To The Flasks / Bottles. It Should Be Provided With Ss Wire Mesh Heater Cover For Efficient Steam Movement And Stable Placement Of The Flasks / Bottles. It Should Have Drain Valve For Draining Chamber Water. It Should Be Provided With An Open Port With Nozzle At Top Of The Lid For Venting Of Steam. It Should Be Provided With Validation Port - For Inserting Additional Sensors - Provided As Part Of Standard Supply. It Should Be Provided With Silicon Gasket Affixed To The Lid To Ensure Leak Proof Operation Even At 100ºc / Boiling Water Temperature. It Should Be Provided With User Settable Pid Digital Temperature Controller With Timer. Temperature Range: Ambient +5 To 100ºc ( Boiling Water Temperature ) . It Should Have Accuracy: ±1ºc & Resolution: 1ºc. It Should Be Provided With Mcb For Electrical Safety.Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors The Vortex Mixer Shall Be Able To Mix Short, Rapid Eccentric Stroke. Motor Driven Neoprene Cup And Capable Of Importing Vigorous Agitation To Small Samples In Test, Centrifuge To Colon Meter Tubes, Erlenmeyer Flasks Up To 100 Ml. Construction Shall Be Provided With Vibrating Plate, Foam Pad And Power Cord Mounted On Vacuum Rubber Feet And On / Off Switch. Workable On 220V Ac, Dimensions Approx. 170 X 110 X 150 Mm Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart Chairs Stainless Steel 304 Quality Matt Finish Seat Height: 1Ft 10Inches With Upright Straight Back Without Arms Rounded Edges
Contract Date: Aug 29, 2023 Contract Value : 12.08 Lakh
Government Departments No of Bidders 3
23.
Educational and Research Institute #2205319 AOC
Supply, Testing, Installation & Commissioning Of Machinery / Equipment / Instrument / Hand Tools / Small Instruments Etc. In Various Trades Of Govt. I.T.I, Hili - 1 Computer I3, 7Th Generation, 8 Gb Ram, 1 Tb Hdd 2 Floor Mats ( 3’X2’ ) Standard Quality 3 Dc Arc Welding Machine ( 400A, Ocv 60–100 V, 60% Duty Cycle ) .Technical Specification:-Input Supply-440V 2Ph.50Hz. + / - 10%, Input Kva-16, No Load Consumption-2Amps, Welding Current Range-40-400A, Duty Cycle -60%, O.C.V-90V A / C, Protection Class-Ip21, Electrode Size-2-4Mm., Type Of Control-Magnetic Mooving Core Type, Type Of Cooling-Fan, Class Of Insulation-Double Fibre Glass With Varnish Covered Flat Conductor, Type Of Core-C.R.N.G.O, M-42Grade, No.Of Output Terminal-3, Mcb Rating-63Amps , Weight Approxx-130Kgs., Chasis Type-Tyre Wheel Mounted.Should Have Welding Amps & Volt Analog Meter. Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. 4 Air Conditioners Window And Split ( 1.5 Ton Used Preffered ) Standard Quality 5 Solar Photovoltaic Power Plant ( 20 Kw ) Pv Module Type- Polycrystalline / Monocrystalline, No. Of Pv Cells Per Module-72 Cells, Total Number Of Pv Modules-28-32 Nos, Max.Power, Pmp@Stc- 300 / 330 / 375Wp, Max.Power Tolerance ( % ) - Complied, Max.Power Voltage ( Vmp ) - 36.5 V, Max.Power Current ( Imp ) @Stc- 8.22 A, Open Circuit Voltage, Voc@Stc- 45 V, Short Circuit Current, [email protected] A, Nominal Voltage-24V, Nominal Wattage- 300Wp, Temp.Coefficient Of Voc-0.3104, Fill Factor-Complied, Temp.Coefficient Of Voc ( % / C ) -0.3104, Temp.Coefficient Of Pmp ( % / C ) -0.3948, Temperature Co-Efficient Of Isc% / °C ) -0.0687, Normal Operating Cell-46+ / - 2, Temperature ( Noct ) ( °C ) - 46+ / - 2, Operating Temperature ( °C ) -40 To 80, Max Temperature Rise Of Solar Cells Under Severe Working Conditions Over Max. Ambient Temp.-10 To 15Deg, Module Is Suitable To Operate At 500 Ambient Temp-Yes, Cell Efficiency-16%-19%, Module Efficiency-15.46%-15.63%, Temp.Coefficient Of Voc ( % / C ) -0.3104, Maximum System Voltage-36.5V Vmp, No. Of By-Pass Diodes-3 Nos, Mounting Arrangement For Solar Module, Clamp Type, Solar Module Frame-Anodized Aluminium, Material-Tempered & Low Iron Glass, Finish-Ethylene Vinyl Acetate, Types Of Sections Used- Aluminium / Ms Sections, Module Dimensions ( 1960 X 990 X 42 ) Mm, Pv Panel Weight ( Kg ) -20.5-22.5Kg, Module Life ( Minimum ) -25Years, Pv Array Area ( Sqm ) -64Sqm Approximate, Guaranteed Output Confirm- Yes, Total Plan Foot Area ( Sqm ) - 120Sqm, Control Area ( Sqm ) -120Sqm, String Monitoring Unit-Built In Pcu / Inverter 6 Over Lock Machine With Stool 4 Thread Over Lock Machine Direct Drive 7 Diagnostic Tool / Scanner For Motor Vehicle Standard Quality 8 Hammer Type Drilling Machine 4-20 Mm, 550 Watt ( 05 Years Amc Required. ) 9 Dual Gauges Set Refrigeration Equipment Standard Quality 10 Spanner D.E. Metric Spanner Double Ended, 6 - 32 Mm. 11 Cleaning Cloth Standard Quality 12 Fender Covers Standard Quality 13 Angle Grinder Machine 2400-Watt  14 Refrigerants M12 Standard Quality 15 Combination Plier Insulated, 200 Mm. 16 Embroidery Machine With Stool And Table 150 Sewing Operations, Lcd- Display, Automatic Needle Threader, Start / Stop Button, Automatically Stops Bobbin Winding, When Full 17 Gear Knob Covers Standard Quality 18 Pug Cutting Machine 220-240 V, 50-60 Hz, Cutting Capacity Upto 50Mm. 19 Empty Cylinder Standard Quality 20 Screwdriver Set Of 5 21 Bar Track Machine No Of Needles 1, No Of Threads 2, Stich Width 40 Mm, Pressure Foot Lifter 13Mm, Box Size 805X375x760 Mm, Heavy Duty ( 05 Years Amc Required. ) 22 Hard Toed Boots Standard Quality 23 Gas Welding Torch Set With Accessories Standard Quality 24 Refrigerants M-22 Standard Quality 25 Torque Wrench ( Standard / Ratchet Type ) , 14 To 68 Nm. 26 Press / Iron ( Any Type ) Standard Quality 27 Hydraulic Jack 20 Ton Standard Quality 28 Gas Cutting Torch Set With Accessories Standard Quality 29 Compressor Old Standard Quality 30 Wire Stripper 150 Mm 31 Pressing Table ( 6’X4’ ) Standard Quality 32 Hydraulic Press 20 Ton Standard Quality 33 Thread Cutter Set Of 20 Pcs Standard Quality 34 Compressor 50 Ltrs. Standard Quality 35 Measuring Tape 5 Meter 36 Garment , Made Ups And Home Furnishing Samples Standard Quality 37 Hydro Meter Standard Quality 38 Dies For Pipe Cutting 20 Pcs Set Standard Quality 39 Filter ( Sample ) Standard Quality 40 Line Dori Standard Quality 41 Drawing Board ( Any Size Wooden ) 850 Mm X 550 Mm 42 Multimeter Dc 200Mv -1000V, 0 – 10A & Ac 200Mv- 750V , 0-10A, Resistance 0- 20 Mω And 3 1 / 2 Digit. 43 Various Drive Socket Standard Quality 44 Drier ( Sample ) Standard Quality 45 Vernier Calliper Vernier Caliper, 150 Mm. 46 Display Board 900 Mm X 600 Mm 47 Oil Draining & Filling Equipment For Vehicle Standard Quality 48 Socket Set 20 Pcs Set Standard Quality 49 Capillary 400  Standard Quality 50 Plumb Bob 500 Gms Standard Quality 51 Types Of Scales:Normal Straight Big Ruler, Hip Curve, Leg Shaper, Pattern Master, Frenchcurve Standard Quality 52 Parts Washing Station Standard Quality 53 Universal Socket Set 10 Pcs Set Standard Quality 54 Capillary 500 Standard Quality 55 Safety Helmet Standard Quality 56 Computer Peripherals Dvd Rom, Blueray Drives, Speaker 57 A / C Leakage Tester Standard Quality 58 Tig Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System. Technical Specification:- Input Supply-440V 3Ph.50Hz. + / - 10%, Input Kva-10, No Load Consumption-0.5 Amps, Duty Cycle -60%, Welding Current Range-20-300A, O.C.V-65V D / C & A / C , Mma Electrode Size-2-4Mm., Tunsten Electrode Size-2Mm-3.15Mm. Type Of Control-Microprocessor Based Digital Soft Switch Control & Pwm , Up Slove / Down Slove Time-1-10Sec, Gas Pre Flow Time-1-10Sec, Type Of Cooling-Fan, Class Of Insulation-“F”, Mcb Rating-40Amps , Protection Class-Ip23, Weight Approxx-32Kgs., Should Have Welding Amps Digital Meter, Hot Start / Arc Force / Background Current Adjustment, 4T & 2T Switching Function, Tig & Mma Dual Functioned, Water Cooling Unit Inbuilt In Main Power Source , Machine Also Have Over Voltage, Phase Missing , Over Current And Over Heat Protection. Accessories List:- Copper 35Sqmm. Hofr Welding Cable -7.5Mtr.Copper 35Sqmm. Hofr Earth Cable-5Mtr. Water Cooled Gtaw Torch-01 Nos. Cooling Tour Machine. Crocodile Type Earth Clamp -01 Nos. Welding Full Helmet With Glass-01 Set.Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. Power Connection Cable 4Sqmm 4 Core -5Mtr. Tungten Electrode-2Mm, 2.5Mm & 3Mm -1Nos. Each, Argon Cylender-7Cum-01 Pcs. Argon Ssdg Regulator-01 Nos.Argon Flowmeter-01 Nos., Argon Transparent Nylon Hose Pipe-10Mtr.Argon Cylender Holding Stand, Torch Collet, Front Cap-05 Nos. Each. ( 05 Years Amc Required. ) 59 Appliances Refrigerator ( One Direct Cool & Other Frost Free Type ) Standard Quality 60 Solar Photovoltaic Inverter:5 Kva Solar Inverter 61 Sewing Kit ( Includes Thread Clipper / Hand Trimmer, Seam Ripper, Fabric Cutting Scissors, Tracing Wheel, Measuring Tape Etc ) 62 Pneumatic Tools For Motor Vehicles Standard Quality 63 Pipe Deburring Tool Standard Quality 64 Capillary 600 Standard Quality 65 Safety Hand-Gloves Standard Quality 66 Machine Tool Kit Standard Quality 67 2 Post Lift Standard Quality 68 Flairing Set Standard Quality 69 Brazing Rod+ Flux Sets Standard Quality 70 Safety Goggles Standard Quality 71 Machine Oil Standard Quality 72 Pullers Standard Quality 73 Pipe Expander Set Standard Quality 74 Screw Bits / Nut Driver ( 41 Piece Set ) Set Standard Quality 75 Safety Harness Standard Quality 76 Machine Needle And Hand Needles ( Various Gauges ) , Embroidery Needles Standard Quality 77 Steering Covers Standard Quality 78 Pipe Threader Set 10 Pcs Standard Quality 79 Testing Board ( Ref / Ac ) Set Standard Quality 80 Reflective Jacket Standard Quality 81 Needle Threader Standard Quality 82 Sun Glasses ( 3 M ) Standard Quality 83 Ratchet Type Pipe Threader Set 1 / 2, 3 / 4, 1 Set Of 3 Pcs Standard Quality 84 Tube Bender ( Mechanical / Tube ) Set Standard Quality 85 Attachments For Sewing Machine Heaming Foot Or Hemmer Foot, Embroidery Plate, Straight Stitch Throat Plate, Rubber, Zipper Foot, Straight Stitch Pressure Foot, Button Foot, Button Hole Stitch Foot 86 Torque Wrenches 5 - 35 Nm Standard Quality 87 Pipe Bender Spool Type Up To 25 Mm. With Stand Manually Operated. 88 Swaging Punch Set Standard Quality 89 Button Hole Scissor Standard Quality 90 Vehicle Safety Stands Standard Quality 91 Gate Valve , Ball Valve, Globe Valve Standard Quality 92 Copper Tube 1 / 2, 3 / 16, 1 / 4, 3 / 8, 5 / 8 ( Roll Set Each ) Standard Quality 93 Hand Notcher ( Pattern Notcher ) Standard Quality 94 Wheel Balancer 5-10 K.W Standard Quality 95 Couplings Standard Quality 96 Teflon Sheet 0.3Mm-6.5Mm Standard Quality 97 Sewing Threads Standard Quality 98 Pvc Pipe Cutter Standard Quality 99 T-Allen Key 2Mm-19Mm Standard Quality 100 Bobbins Standard Quality 101 Regular Plier Standard Quality 102 L-Allen Key 1.5Mm, 2Mm, 2.5Mm, 3Mm, 4Mm, 5Mm, 5.5Mm, 6Mm, 8Mm, 10Mm. Standard Quality 103 Design Softwares ( Coral, Photoshop Etc ) 104 A / C Machine ( 124 Robin Air ) Standard Quality 105 Mig Welding Machine Gmaw Welding Machine 400 A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessoires, 415 Volt +- 10% Ac, Ac 3 Phase, 21.5 Kva, Vac 400-415, 50 / 60 Hz, Duty Cycled 60-100, Vdc Out 34 Vdc, Ocv High 62 Mic / Msg Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. ( 05 Years Amc Required. ) 106 Work Table ( 5X3x2.5 ) Standard Quality 107 Battery :Battery Type- Lmla / Vrla, Voltage-12 / 24 V, Ah Capacity- 65 / 100 / 150Ah, Container -Battery Rack, Cover- Polypropylene Copolymer ( Ppcp ) , Terminals- M, Electrolyte, Self Discharge-≤5% ( As Per Is13369≤10% ) In 28Days, Life Expectancy- 5 Years, Approval-Yes, Service Life-Minimum 5 Years, Ah Efficiency- Above 90%, Charge Efficiency- Above 80%, Maximum Depth Of Discharge ( Dod ) -0.9 108 Bobbin Case Standard Quality 109 Water Pump Plier Standard Quality 110 Nose / Combination Pliers ( Insulated 150 Mm ) , Tong Pliers 150 Mm 111 Hanger Wooden And Plastic Material 112 Combination Plier 200 Mm Standard Quality 113 Tube Cutter 100 Mm Standard Quality 114 Embroidery Frame 4’X6’, 3’X2’, 2’X2’ Standard Quality 115 Adjustable Wrench 6” Standard Quality 116 Wire Brush Standard Quality 117 Fabric Yardages, Surplus Fabric, Good Quaity Muslin Mandatory 45 Mtr Each 118 Adjustable Pipe Wrench 8” Standard Quality 119 Paint Brush ( 50 Mm ) Standard Quality 120 Trim / Accessory Buttons, Surface Embelishments, Zippers 2 Dozen Each Standard Quality 121 H Eavy Duty Pipe Wrench 300 Mm Standard Quality 122 Hammer Ball Pin 500 Gms Standard Quality 123 Pin Cushion Standard Quality 124 Pipe Wrench Chain Type Standard Quality 125 Monkey / Adjustable Plier 20 Mm Standard Quality 126 Dustbin Standard Quality 127 Aluminium Pipe Wrench 450 Mm Standard Quality 128 Fixed Spanner ( 10-11, 14-15, 16-17 Each ) Standard Quality 129 Boxes And Pouches For Storing Items Standard Quality 130 Hammer Type Screw Driver 100-250 Mm Standard Quality 131 Neon Phase Tester ( Insulated 150 Mm ) Standard Quality 132 Pattern Table / Cutting Table Standard Quality 133 Screw Drivers 200 Mm Standard Quality 134 Round File ( Smooth 150 Mm ) Standard Quality 135 Stools For Cutting Standard Quality 136 Screw Drivers Insulated Type 150 Mm 137 Flat File ( Smooth 200 Mm ) Standard Quality 138 Printer Multipurpose 139 Air Compressor 50 Ltr. Standard Quality 140 Electrofusion Welding Machine Hdpe Electrofusion Welding Machine , 20 To 315 Mm Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. ( 05 Years Amc Required. ) 141 Bins For Tools Standard Quality 142 Clampmeter 0 - 100 A ( Digital Type ) . 143 Students Chair ( With Table Arm ) Standard Quality 144 Screw Driver Bit Set Of 10 Pcs Standard Quality 145 Hacksaw With Blade ( 150-200 Mm ) Standard Quality 146 Teachers Table Standard Quality 147 Open Spanners De Set Of 10 Standard Quality 148 Long Screw Driver ( 250 Mm ) Standard Quality 149 Teachers Chair Standard Quality 150 Ring Spanners Set Of 10 Standard Quality 151 Tommy ( Mini 0 Screw Driver-Flat Head ( 550 Mm Tip ) ) Standard Quality 152 Push Pins Standard Quality 153 Double Ended Spanners Set Of 10 Standard Quality 154 Fire Extinguisher ( Abc Powder Type 2 Kg ) Standard Quality 155 Dress Makers Pin Standard Quality 156 Adjustable Spanners 6” Standard Quality 157 Fuse Standard Quality 158 Fabric Pins Standard Quality 159 Ratchet Type Spanners 12 - 16 Mm Standard Quality 160 Compressor Relay Standard Quality 161 Highlighter Standard Quality 162 Tubular Box Type Spanners Set Of 12 Standard Quality 163 Freezer Thermostat Standard Quality 164 Pencil ( Hb, 2B, H, 2H, 4H, 4B, 6B, 8B ) Standard Quality 165 Bolt Cutters Standard Quality 166 Defrost Timer Standard Quality 167 Eraser Standard Quality 168 Hammers 1Kg 169 Megger Standard Quality 170 Note Books Standard Quality 171 Soft Hammers Standard Quality 172 Watt Meter Standard Quality 173 Photocopier Standard Quality 174 Battery Charger ( For 6V, 12V, V24v Battery ) 175 Pipe Cutter Machine Disc Diameter : 355 Mm ( 14 ) Cutting Capacity ( Square Bar ) : 119 X 119 Mm Cutting Capacity ( Round Pipe ) : 129 Mm No Load Speed : 3800 Rpm Power Input : 2200 W 176 First -Aid Box With All Material Standard Quality 177 Multimeter Dc 200Mv -1000V, 0 – 10A & Ac 200Mv- 750V , 0-10A, Resistance 0- 20 Mω And 3 1 / 2 Digit. 178 Sharpener Standard Quality 179 Allen Key Set 1.5 -10 Mm Standard Quality 180 Digital Clamp Meter 115 Amp Standard Quality 181 Carbon Paper ( Various Colours ) Standard Quality 182 Cold Chisel Standard Quality 183 Digital Thermometer Standard Quality 184 Design Transferring Paper Standard Quality 185 Steel Rules Standard Quality 186 Measuring Tape ( 5 Mtrs ) Standard Quality 187 Paper Cutter Standard Quality 188 12” Hack Saw Frame With Blade Standard Quality 189 Pressure Guage Standard Quality 190 Pattern Drafting Paper Standard Quality 191 Punch Centre , 150 Mm X 9 Mm Standard Quality 192 Compound Guage Standard Quality 193 Paper ( Various Quality And Sizes ) Standard Quality 194 Try Square 10 Cm Blade Standard Quality 195 Capilary Guage Standard Quality 196 Labels & Stickersstandard Quality 197 Crow Bar Standard Quality 198 Scissors ( Plastic Handled Scissor For Cutting Paper ) 199 Lever Bar Standard Quality 200 Pinking Shears Standard Quality 201 Full Harness- ( Half Body ) Standard Quality 202 Marking Chalk ( Yellow / Pink / Green / Blue Coloured ) 203 Full Harness- ( Full Body ) Standard Quality 204 Projector Dlp Hd Celing Mounted 3500 Lumens 205 Bc Clamp Meter Standard Quality 206 Fume Extractor Standard Quality 207 Service Manual / User Manuals ( Each ) Standard Quality 208 Earth Tester Analog - 500 V. 209 Tailor’S Chalk Standard Quality 210 Ladder Hook Standard Quality 211 Carbon Paper ( A4, Yellow, Red And White Carbon ) 212 Asbestos Hand Gloves Standard Quality 213 Colour ( Poster Colour, Water Colour, Acrylics, Pastels, Fabric Printing Dyes And Colors And Materials Etc ) 214 Blue Aprone Standard Quality 215 Paint Brushes ( Different Sizes ) Standard Quality 216 Leather Jacket Standard Quality 217 Stapler ( Small And Big Size ) Standard Quality 218 Welding Gloves Standard Quality 219 Glue Stick / Fevicol / Adhesive Standard Quality 220 Hand Sleeve Standard Quality 221 Fabric Glue Standard Quality 222 Leg Guard Standard Quality 223 Cello-Tape ( Transparent And Foam Double Sided Tapes, Single Sided Tapes ) 224 Ear Plug Standard Quality 225 Punching Machine Standard Quality 226 Cutting Goggles Standard Quality 227 Magnetic White Board / Black Board Eraser Standard Quality 228 Welding Goggles ( Black ) Standard Quality 229 Mannequin Lady, Men, Kid ( Boy & Girl ) Standard Quality 230 Bench Grinder Standard Quality 231 Power Hacksaw Hydraulic Feed System 400 Mm. Blade Size, Motor Capacity -0.75 Kw 232 Personal Protection Equipment Standard Quality 233 Spirit Level 30 Cm Standard Quality 234 Blackboard & Whiteboard 900X600 Mm 235 Nose Mask Standard Quality 236 White / Blackboard Marker Standard Quality 237 Welding Hand Screen ( Shield ) Standard Quality 238 Pantone Shade Card Standard Quality 239 Welding Head Helmet ( Shield ) Standard Quality 240 Auto Darkening Helmet Standard Quality 241 Buyer Requirement / Comment Sheet Standard Quality 242 Electrical Hand Gloves Standard Quality 243 Measurement Sheet / Size Chart Standard Quality 244 Operator Gloves Standard Quality 245 Trims / Accessory / Fabric And Embroideries Samples / Swatch File Standard Quality 246 Tech Pack / Specification Sheet Standard Quality 247 Chalk &Marker ( Chalks & Markers Of Different Colours ) Standard Quality 248 Dexterity Test Kit Standard Quality 249 Power Operated Sewing Machine2000-3000 Stitch / Min With Table 250 Car Seat Covers Standard Quality 251 Bench Drilling Machine Drilling Machine Bench Input Power : 680 Watt, Max. Drilling Capacity : 12Mm, Spindle Travel: 60Mm, Working Radius: 143Mm, Working Size : 205X205mm, Column Size: 45X500mm. 252 Brazing Kit ( 1 Swirl Type ) Standard Quality 253 Pyranometer Standard Quality 254 Sewing Machine Tool Kit Standard Quality 255 Color Matching Light Box Standard Quality 256 Students Notes Standard Quality 257 Stools For Sewing Depending On No. Of Machines Standard Quality 258 Cotton Gloves Standard Quality 259 Rotary Type Drilling Machine 750 Watt 260 Male - Female Couplers  Standard Quality 261 Heavy Duty Rotary Type Hammer Drill Machine 20 Mm ( 05 Years Amc Required. )
Contract Date: Nov 18, 2021 Contract Value : 71.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
24.
Educational and Research Institute #1549672 AOC
Supply Of Lab Equipment To Common Instrumentation Lab Of Govt. Brennen College , Equipment For Centre Of Excellence , Ftir Spectrophotometer-Spectral Range: 8, 000–350 Cm-1 Optimized, Mid-Infrared Kbr Beam-Splitter.Signal-To-Noise: Summit Spectrometer – 35, 000:1 ( Peak-To-Peak, One Minute ) .Wavenumber Precision: 0.001 Cm-1 At 2, 000 Cm-1.Wavenumber Accuracy: 0.05 Cm-1 At 2, 000 Cm-1 Ordinate Linearity ( Astm E1421 ) : <0.15 %T Deviation From 0.0%T.Infrared Source: Non-Migrating Hotspot, Single-Point Source For Unmatched Data Reproducibility.Laser: Solid-State, Temperature Controlled Diode Laser With Long Lifetime. Interferometer: Dynamically Aligned Interferometer With Kbr / Ge Mid-Infrared Beam-Splitter Optimized For Highest Spectral Throughput.Detector: Fast-Recovery Deuterated Triglycine Sulfate ( Dtgs ) . Power Consumption: 100-240 Vac, 47-63 Hz, 110 W.Tightly Sealed And Desiccated Optical Compartment With Protective Kbr Windows For Humidity And Vapor Protection.User-Replaceable Components ( Without Opening Cover ) : Desiccant, Power Supply, Sample Compartment Windows, Infrared Source. Interface / Connections: Mini-Display Port Connection To Monitor, Ethernet Connection To Laptop Computer Light Bar: Multi-Colored Led Bar Displays System Status And Spectral Library Match Value / Qcheck Result.All Optics Should Be Sealed In A Metal Alloy Chassis For Enhanced Durability, Robustness, And Moisture Control. Should Be Provided Internal Nist-Traceable 1.5 Mil Polystyrene Film ( Serialized ) With Traceable Certificate. Should Be Provided Original Licensed Version Library At Least 5000 Spectra. Ftir Must Be Having Cloud Based Connectivity For Remote Access Data. Diagnostic: Continuous Electronic Monitoring Of Multiple Spectrometer Components With Temperature And Humidity Sensors And Diagnostic Status Displayed On Light Bar. Software Capability: Dashboard / Home Screen For Quick Access Of Recent Work, Visual, Drag And Drop Workflow Creator With Example Templates, Live Displays Of Data Collection And Spectral Data Preview, Connectivity To Omnic Anywhere Cloud-Based Application, Smart Background Feature Cuts Measurement Time By 50%, Optional Advanced Instrument Health Information Tracking, Flexible, One-Click Library Creation, Pre-Defined Reporting Templates Exportable To Microsoft Office Suite, Multi-Component Search Functionality. Full Spectral Processing And Analysis Tools ( Baseline Correction, Spectral Math, Peak Area, Peak Height, Etc ) , Quantification Prediction For Beer’S Law, Pls, Cls, Etc. , Automated Workflow Creator Based On Spectral Processing History. Warranty: 3 Year Warranty For Instrument And 5 Years Warranty For Laser And Interferometer. Should Be Provided Kbr Pellet Making Complete Kit. Should Be Provided Branded Latest Version Desktop. Vendor Should Be Provided At Least 5 User List In Kerala. Vendor Should Be Having Service Facility At Kerala, Service Centre Address To Be Furnished. , Spin Coating Unit : Programmable Model Ideal For Scientific Research Works.Ptfe Coated Ss Working Chamber Of 200 Mm Diameter. Programmable Speed Range Of 100-10, 000 R.P.M [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] Programmable Acceleration Period Of 1-250 Seconds [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] . Programmable Acceleration Range Of 40-5, 000 R.P.M / Sec [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] . Programmable Controlling Duration Range Of 1-9, 999 Sec / Step. Real-Time Display Of R.P.M Vs. Time In 4 Line Lcd Display. 2 User Programs Available, 10 Steps / Program Available, Warm-Up Option Available, Calibration Option Available, Spill Drainage Facility Available. High-Speed Dc Motor For Fast Speed Reaching.Non-Volatile Program Memory, User-Friendly Firmware Interface, N2 & Other Inert Gas Purging Port Available. Integrated Power On / Off Switch Available. Integrated Vacuum Release Switch Available. Transparent Photo-Resist Acrylic Safety Lid Available. Input & Controlling Through Key-Pad. Indian Standard Power Input Vendor Should Be Provided Manufacturer Authorization Certificate.Vendor Should Be Having Service Facility At Kannur Or Nearest Districts, Service Centre Address To Be Furnished. Standard Oil Free Vacuum Pump:- Power: Indian Standard. Vacuum: 560 Mm / Hg. ( Maximum ) . Flow Rate: 15 L / Min. Maximum Operating Pressure: 25 Psi, Horse Power: 1 / 20 Hp, Dimension: 150 Mm X 110 Mm X 140 Mm. Net Weight: 2.5 Kg, No Lubrication Required. Noise Less , Absolutely Portable, Totally Oil-Free Construction, Practically Maintenance-Free. All Parts Made From Special Graded Aluminium Die-Cast Material For Light Weight & Good Strength. Diaphragms Are Made Of Special Type Polynylon & Reinforced Neoprene Rubber Built-In Micro-Suction Filte, Extra-Large Bearings For Trouble-Free & Smooth Running. Warranty : 1 Year , Furnace With Programmable Temperature Controller: Furnace Capacity Will Be 16 Ltrs Or More. Temperature Range Will Be 100°C To 1200°C Or Better. Power Consumption: 4500W Or Less. Thermocouple Type: Platinel Ii Thermocouple Or Better For Long-Term Stability. Will Be Having E Lgo Heating Elements And Moldatherm Insulation For Efficient And Economical Transfer Of Heat To Chamber, With Low Exterior Temperatures. Self-Tuning, Digital Instrumentation For Precise Temperature Setpoint And Display. Air Vent ( 1 In. Dia., Top ) And Air Inlet ( 0.375 In. Dia., Rear ) For Inert Atmosphere Exchange. Microprocessor-Based Self-Tuning Pid Control Provides Optimum Thermal Process, Prevents Overshoot. Adjustable High-Limit Over Temperature Protection. Simultaneous Led Display Of Actual Temperature Vs. Setpoint In °C Or °F. Safety Door Switch Interrupts Power To Heating Element When Door Is Opened; Protects Heating Elements And Minimizes Exposure To End-User. Shelves Will Be A Removable And Easy Cleaning. Controller Type: Digital Single Set Point Controller. Single Segment, Single Set Point, One Ramp To Set Point. Super Control ( Fuzzy Logic ) Suppresses Overshooting Of Temperature. Overrides Main Controller And Shuts Off Power To Furnace If High Limit Is Reached. Operates Via Magnetic Contacts Through Signal From Independent Thermocouple. Furnace Must Have An Optional Rs485 Digital Communications Port Facility. Should Be Provided Two-Way Communications Set Up Between Furnace And Remote Computer. Furnace Must Have The Options Of Remote Monitoring And Control Of Furnace Equipment. Must Have An Ability To Connect Up To 30 Furnaces To One Personal Computer.Certifications: Ul And Ce ( International Certifications ) .Furnace Must Have Globally Accepted Brand. Warranty: 1 Year , Vacuum Oven With Pump- Specification For Vacuum Oven And Pump: Vacuum Oven With Chamber Capacity 30L. Temperature Range Rt+5~200ºc. Vacuum Degree 133Pa Or Better. Inner Chamber Should Be 316 Stainless Steel Mirror Polish. Pid Controller With Led Display, Over Temperature Warning And Timing Function. Square Chamber Design With A Large Dual Layer Tempered Glass On The Door Allows For Excellent Observation. Led Lights On The Door For Easy Viewing Of Sample. Silicon Door Gasket For Long Life And Better Vacuity. Display Resolution 0.1 And Temperature Stability ±1ºc.Minimum 2 Nos. Ss 316 Shelves Power Consumption 850W Or Less Vacuum Pump ? Dual-Stage Rotary Vane Vacuum Vacuum Pump ? Proven Vane Technology Ensures More Stable Performance ? Built In Gear Pump And Constant Pressure Oil Supply System Enable Steady And Dependable Operation Even When Suction Pressure Is High ? Electric Solenoid Valve Ensures That The System Maintains A Vacuumstate When Power Is Turned Off, Hence Preventing Oil Suck Back ? Ultimate Partial Pressure Gas Ballast Close 1×10-1 Pa ? Ultimate Total Pressure Gas Ballast Close 3Pa ? Ultimate Total Pressure Gas Ballast Open 20 ? Level Of Protection Ip44 ? Intake And Exhaust Kf16 ? Motor Speed 1440 Or Better ? The Equipment Ce Certified ? Warranty Two Years Minimum. , Source Meter- With Silver Electrodes Single Electrode Maximum Current Source / Measure Range – 1 A Maximum Voltage Source / Measure Range –20 V Measurement Resolution ( Current / Voltage ) -1Pa / 100Nv Power -20W , Digital Balance-Four Digit Electronic Precision Balance • Capacity: 220G ; Minimum Display: 0.1Mg • Repeatability ( Standard Deviation ) : =0.1Mg • Linearity: ±0.2Mg • Stabilization Time: 3 Seconds Or Less • Operating Temperature And Humidity Limits :5-40°C 20-85%*2 • Temperature Coefficient Forsensitivity ( 10-30°C ) : ± 2 Ppm / °C • Pan Size ( Mm ) Approx.: Ø91 • Main Body Dimensions ( Mm ) Approx.: 213 ( W ) 356 ( D ) 338 ( H ) • Main Body Weight ( Kg ) Approx.: 6.2 • Power Requirement: 12V, 1A • Calibration: Touch Key Internal Calibration • Instrument Should Be An Internationally Accepted Imported Brand. • Vendor Should Be Provided Specific Oem Authorization Certificate. • Usb Port, Rs 232 Facility Available. • In-Built Specific Gravity Software • Certifications: Iso And Ce Certified • Electronic Balance Should Be Multinational Accepted Imported Brand. • Electronic Balance Should Have The Features Of Easy Setting, Expanded Piece Counting Function, • Comparator Function, Formulation Mode, Power Saving Function, Windows Direct Communication Function, Power Lock • Vendor Should Be Provided Specific Manufacturer Authorization Certificate. • Vendor Should Be Having Service Facility At Kerala; Details Of Service Centre Should Be Furnished. • Warranty: 2 Years With Periodic Preventive Inspection Every 3 Months During The Warranty Period , Digital Ph Meter - Metal With Dimensions 15 X 14X 6 Centimetres; Weight 4 Kg; 5Year Warranty , Agate Mortar With Pestle For Laboratory Use Material- Agate Diameter 8-10 Cm , Ultrapure Water Purification System 1 ) Water Purification System Should Be Capable Of Producing 18.2 Megaohm Resistivity With Pre-Treatment Cartridge, Reverse Osmosis And Mixed Bed Ion Exchange Resins And Activated Carbon In A Single Pack, With Feed Water Acceptance Of Upto 2000Micro Siemens Conductivity, Fouling Index ( Sdi ) < 12, Total Chlorine < 1 Ppm. 2 ) All In One Pack Which Contains A Combination Of Technologies To Produce Ultrapure Water From Tap Water Directly. 3 ) The 1St Stage Of The Ro Di Cartridge Contains Pre-Treatment For Reverse Osmosis Followed By Ro Membrane. 4 ) The 2Nd Stage Contains Mixed Bed Ion Exchange Resin And Organex For Removal Of Organic Contaminants. 5 ) It Should Have Only One Cartridge In The System. If The System Comes With More Than One Cartridge Then That Cartridge Should Quote Mandatorily 20 Numbers ( Including Ro ) Along The Main Quote. Need To Furnish Above Mentioned Cartridge Catalogue Number With Quantity In The Technical Bid. 6 ) Type 3 Water Flow Rate Should Be 3 Litre / Hour. Product Waterspecifications Resistivity:18.2Meg Ohm.Cm ( @ 25 Degree C ) Conductivity: < 0.055Us / Cm Toc : <10 Ppb Bacteria :< 0.1 Cfu / Ml Pyrogen : <0.001Eu / Ml Rnase: <0.01 Ng / Ml Flow Rate : 0.5 L / Min Particulates> 0.22U:<1 P / Ml , High Resolution Stereo Zoom Microscope With Camera Optics Carrier; Magnification Range:8X-160X Or More ( 10X Eyepieces And 1X Objective ) Apochromatic Corrected Optics. Maximum Upgradable Magnification 1270X Or More. Should Offer Simultaneous High Resolution And Depth Observation.Zoom Ratio; 20.5:1 Or Better. Eyepiece; 10X / 23B, Dioptre Adjustable, Wide-Field Eyepiece For Spectacle Wearers, Designed For Using Graticules, With Exchangeable Soft Eyecups Base; Incident Light Base, Large With Anti Shock Feet With Stage Insert Black / White ( 120 Mm ) Focus Drive; Motor Focus Drive Long 410Mm Or Above Usb Interface And 3 Can Connectors To Interface Accessories. Illumination ( Led ) ; High Diffuse Illumination Domelight With 2 Independent Controllable Ring Lights, Control Panel Foron / Off, Brightness And Lightcontrols. Tube; Inclined Binocular Tube 45°, Interpupillary Distance 52-76 Mm, Documentation Tubewith Beam Splitting Switchable 0 / 50 / 100 %, Resolution And Working Distance; Maximum Resolution 1050 Lp / Mm, Working Distance 60Mm External Control Unit; Hand Wheel / Smart Touchto Control The Microscope Camera; Dedicated Digital Scientific Grade Camera Capable Of Taking High Resolution Images With Cmos / Ccd Sensor. Minimum 12 Mp Or Better Pixel Dimensions: 1.55 ?M X 1.55 ?M Or Better, 4K 60Fps Live Image Via Hdmi, Jpg Images With Up To 12 Mp Full Hd Mjpg Video Recording With 30 Fps Should Have Upgradation Facility Of Stand Alone Digital Imaging Station Software; Compactable Softwarefor Image Acquisition Full Control Of Camera Features ( Exposure, Gain, Gamma And Region Of Interest. ) . Software Has The Ability To Control Motorization And Z- Stacking. Automatically Capturing A Given Number Of Images And Stitching Together To Get A Perfect 3D Image. Measurement Module For Generating Measurement Parameters Such As Length, Distance, Area, Perimeter, Diameter And Angles. All Measurements Are Displayed In An Interactive Table And Can Be Exported To Excel Or Used To Generate Reports. Computer; I5 64-Bit Processor, 8 Gb Ram, 1Tb Hdd, 1Gb Graphics Card, 24 Inch Monitor, Windows 10 Warranty; 2 Year Warranty And 3Rd Year Amc. All The Components, Microscope, Camera, And Software Should Be Same Make , Ultra Deep Freezer -80 Degree Temperature With Hydrocarbon Refrigerant• Capacity Should Be Minimum 540 Liters Capacity With Minimum 4 Inner Doors • 2 Box Capacity: 400Nos• 2Ml Vial Capacity: 40000 • Temperature Range Should Be -50°C To -86°C• Noise Level: 51 Db Or Below • Energy Consumption ( Kw-Hr / Day ) : 12.3 Or Less• Door Opening Recovery Time Will Be17 Minutes Or Less • Warm-Up Time ( -80°C To -50°C ) Will Be 257 Minutes Or More.• The Freezer Must Be Constructed Using 1” Thick Vacuum Panel Insulation In Conjunction With Environmentally-Friendly Water Blown Foam.• Door Gasket Must Provide 7 Independent Insulation Zones Along With 4 Points Of Contact To Ensure Sample Security. • Freezer Shall Be Painted With High-Impact, Scratch Resistant Powder Coat Finished Interior And Exterior To Ensure Long Term Viability And Enhanced Temperature Uniformity. • To Reduce Condensation, The Perimeter Heater Shall Be On The Door Side Not On The Cabinet Side To Limit Heat Introduction Into The Sample Storage Area. • The Thermal Breaker Shall Be Made Of Plastic To Limit Heat Leakage Into The Cabinet Door Latch Allows One-Handed Opening And Closing. • Handle Must Include Door Key Lock As Well As Padlock Provision For Added Security. • Freezer Shall Have 4 Compartments With A Minimum Of 4 Polystyrene Insulated Inner Doors To Ensure Sample Security. • Inner Doors Should Have No Latches Or External Magnets And Must Be Removable For Easy Cleaning Without The Use Of Tools. • Freezer Shall Have An Automatic Heated Pressure Equalization Port Which Allows For Rapid Re-Entry To Cabinet. • Freezer Shall Have Two-1 Inch Access Ports As Standard. • Freezer Shall Have A Rs485 Output, Dry Contacts And 4-20Ma Output For Remote Monitoring Purposes. Freezer Door Must Open At Least 180 Degrees For Easy Sample Access. • Freezer Shall Incorporate Set Point Security Freezer Interface Shall Incorporate Icons To Advise Users Of Alarm Status For Warm Or Cold Excursions, Door Ajar, Or Power Failure. • Freezer Interface Shall Allow For The Use Of An Off-Set Value To Be Used For Calibration. • Freezer Shall Have The Option Of Either An Liquid Nitrogen Or Carbon Dioxide Back-Up System. • Freezer Shall Have The Option Of A Chart Recorder. • Freezer Shall Record Temperature Excursions Including Actual Temperature, Warmest Temperature And Coldest Temperature. • Freezer Must Recognize If Line Voltage And Frequency Does Not Match Freezer Specification And Alert User. • Refrigeration System - Freezer Shall Use Only Natural, Commercially Available Refrigerants ( Hydrocarbon ) With No Special Blends Required. • Connectivity: External Monitoring / Cloud Compatible; 4-20Ma, Rs485, Dry Contacts • Meets + / -10°C Validation Protocols At -80°C With Strong Peak Variation And Steady-State Temperature Variation • Freezer Must Be Built To And Contain The Registration Mark For Ul, Cul, And Ce Standards For Safety And Performance. • Should Be Fda Class Ii Medical Device Warranty Minimum 5 Years On Complete System From The Manufacturer. • Warranty: 5 Years Vendor Should Be Supplied Suitable 5 Kv Servo Stabiliser , Refrigerated Centrifuge Centrifuge Should Have Maximum Capacity Of 4 X 144 Ml Or More Centrifuge Should Have Maximum Speed 17, 500 Rpm Or More Centrifuge Should Have 30, 000 G Or More Secure, Easy Rotor Exchange Delivers Trouble-Free Rotor Installation / Exchange. The Centrifuge Must Be Compatible With Swinging Bucket Rotor, Fixed Angle Rotor And Microplate Rotorstemperature Range: -10°C To 40°C Noise Level: <56Dba Safety Feature: Rotor Detection System, Imbalance Detection Systemrefrigeration System: Cfc Free Drive System: Direct, Brushless Induction Drive One-Touch Operation With Pre-Saved Protocolsprograms: 3 Or 4 Direct Programs Warranty: 2 Years With Periodic Preventive Inspection On Every 3 Months During Warranty Period3 End User Performance Certificate Should Be Provided Centrifuge Conforms To The Latest Clinical And Safety Standards Such As Ul, Ce And Ivdwill Be Provided The Following Rotors Suitable For High Speed Applications 24 X 1.5 / 2 Ml Rotor6 X 50 Ml Fixed Angle Rotor15ml Adapterstrip Rotor Microplate Rotor , Double Beam Uv Visible Spectrophotometer Optical Design: Double Beam • Light Source: Xenon Flash Lamp With 3-Years Warranty And At Least 7 Years Life• Detector: Dual Silicon Photodiodes • Wavelength Range: 190 –1100 Nm • Wavelength Accuracy: ±0.5 Nm • Spectral Bandwidth: 2 Nm Or Better • Wavelength Reproducibility: <±0.02 Nm ( 546.1 Nm Mercury Line, Sd Of 10 Measurements ) • Data Interval: 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm • Photometric Range: –2A To +3.5A • Photometric Repeatability: ±0.001A At 1A • Photometric Display: -3A To 5.0A • Baseline Flatness: ±0.0010A, 200-800Nm, 1.0Nm Sbw • Noise: =0.00020A At 0A At 260 And 500 Nm =0.00030A At 1A At 260 And 500 Nm =0.00040A At 2A At 260 And 500 Nm • Drift : <0.0005A / H • Baseline Flatness: ±0.002A • Stray Light : < 1.0%T 198 Nm ( Kcl ) , <0.05%T At 220 Nm ( Nai ) , <0.03%T At 340 Nm ( Nano2 ) • Display : 7 Inch Color Touch Screen, Tiltable, High Definition, 800 × 1280 Pixel • Keypad: Touch Screen • Warranty: 3 Years • Included 8-Position Cell Changer As Standard. • Usb Memory Device • A Pair Of Quartz Cuvette With 10 Mm Path Length And 3.5 Ml Volume • Free Of Cost Installation , Training And Demonstration At Site , Horizontal Electrophoresis Unit With Power Pack• The Horizontal Electrophoresis Unit Must Include 10X10cm Tray. • Gel Trays Should Be Uv Transparent. • Lid And Cables Should Be Separate And Must Not Be Attached.• Bromophenol Blue Migration Should Be Approx 4-5Cm / H At 90V.• Run Time Should Be 45-60 Min At 90. • Should Include 1 Mm Thick 2 Combs Of 16 Sample Wells.• Buffer Volume Should Not Be More Than 300Ml.• Tank Of The System Should Be Single Moulded To Ensure Leak Proof Buffer Tank. Even The Parts Should Also Be Single Molded That Are Easy To Repair And Replace.• 16 Sample Combs Should Have 16 ?L Sample Capacity In Each Well.• The Electrodes Should Not Be Attached To The Tank And Should Be Cassette Type Electrodes For Easy Repair And Replacement.• Should Have Pure Platinum Wire And Gold Plated Corrosion Resistant Electrodes.• Should Include Casting Dams For Tape Free Casting Of Gels.• Should Include Loading Guides For Easy Identification Of Wells.• Should Have Color Coded Combs Option And Should Have Options For 0.75Mm, 1Mm, 1.5Mm And 2Mm Combs.• It Should Support Widest Range Of Combs To Run Up To 100 Samples. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .Power Supply:- • The Power Supply Should Have 300V, 400Ma And 60W With 1V / 1Ma Resolution.• The Output Of The Power Supply Should Be Constant Voltage Or Constant Current.• The System Should Have Timer For 1-999 Mins With Alarm.• Should Have 3-Digit Led.• The Power Supply Should Have Provision To Connect Two Gel Chambers. • Should Have Alarm Function.• Should Have Microprocessor Control.• The System Should Have Auto Cut-Off Function.• Safety Features Includes Shrouded Plugs And Sockets, No Load Detection, Overload Detection, Over Voltage, Current & Temperature Protection, And Maximum Power Output Detection. • The Unit Should Have En-61010-1 & Ce Regulatory Conformity. • Operating Conditions Should Be Ambient-40°C, =95% Humidity.• Operating Conditions Should Be 100-240 Vac. • The Power Pack Dimensions Should Not Be More Than 140X191x84mm ( Wxdxh ) .• Weight Of The Power Pack Should Not Be More Than 1 Kg. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And• Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of • Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .• Vendor Should Be Submit Authorization Certificate, Having Service Facility At Kerala, Service Centre Address To Be Furnished.• Warranty: 1 Year , Pcr Thermal Cycler • Block Format Should Be 96 Well Gradient Or Veriflex Block • Heating Mode: Peltier Heating.• It Should Be Capable For 0.2Ml Pcr Tubes, 8X0.2 Ml Strips And 96 Well Microplates. • Temperature Range: 4-100 Degree Cel. Heated Lid Up To 110°C• The Ramp Rate Should Be 3.5 Degree Cel / Sec. Or More • Max. Sample Ramp Rate: 2.5°C / Sec Or Above• Pcr Volume Range 10–100 ?L • System Should Need A Color Lcd / Led Touch Screen For Step Based Graphical Programming• 500 Mb Or Above Onboard Memory • Temperature Calibration Should Be Calibrated To Standards Traceable To The National Institute Of Standards And Technology • Instrument Should Have Cloud Based Tools Allow To Securely Store, Access, Share And Manage Data Remotely.• It Should Be Duly Certified For Pcr Process. • It Should Need Provision For Usb, Cloud Via Ethernet And Pc.• Warranty 2 Years , Micro Pippet Set Volume Ranges: 0.2-2 ?L, 2-20 ?L, 20-200 ?L, 100-1000 ?L Flex Tips: 10, 1 × 96; 200, 1 × 96;1000, 1 × 96 Warranty: 5Yearsor More Reagent Reservoir Demo Pack Pippets Stand Fully Autoclavable Volume Gearing Mechanism For Accuracy And Precision. Should Be Extremely Light Should Have Soft Touch Tip Ejector Large Display Prevents Eye Strain Very Light Pipetting Forces For Greater Accuracy With Less Fatigue Fully Autoclavable Vendor Should Be Provided Authorization Certificate For Specific Tender / Quotation
Contract Date: Mar 16, 2023 Contract Value : 99.68 Lakh
Local Bodies No of Bidders 14
TenderDetail
Loading tenders