View Bid Results For Air Circulation Tenders

We found 758 Bid Results related to air circulation tenders. You can find Contractor details who won air circulation tenders along with contract details in Bid awards announcements section.

Filters
Stage
584
105
69
Tender Publishing Platform
177
581
State / UT
32
106
88
69
61
59
54
34
33
29
28
26
26
25
23
15
10
10
9
8
7
7
6
5
5
4
2
2
2
2
1
1
1
Contract Value
227
194
235
100
Publish Date
6
0
0
0
0
Sector
28
169
103
88
63
48
48
38
36
35
25
12
11
10
9
9
9
8
7
7
5
4
4
3
2
2
1
1
1
Ownership
7
321
187
143
90
11
5
1
Within keyword
Active filters:
Showing 1–16 of 758 tenders matching your filters
3.
Power #11475580 AOC
Bids Are invited for Handing and Dragging of Transformer from stacking yard to repairing hall with accessories. , Cutting/Opening of top cover plates & fitting of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free. , Reconditioning/ Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one. , Reconditioning/Making of H.V leg coils from new DPC or SE wire of same size and No. of turns and dimensions as old one. , Assembly of core, channel (duly painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing area. , Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out empty tank after painting to assembly area. , Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with super enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Unique number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools. , Dismantling of core & coil Assembly and its cleaning. , Dismantling of Shell Core and coil assembly. Removing of HV and LV Leg coils for assessing its reuse, reuse of major insulating material if possible, checking and recording of physical dimensions of coil. , Making of complete HV & LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled/DPC conductor/ Strip confirming to IS 1971 153 in place of old and damage coil. Alu.coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Shell Coil shall be supported between adjacent sections by insulations (flick Paper) Paper, spacers, beamers and other insulations. Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of , Assembly of Shell core (Three Limbs) coils and fitting of top and other parts. Replacement of insulation such as press board, craft paper, making support between adjacent section by insulating spacers and wrapping etc. shifting of repaired core coil assembly and placement inside the oven for proper dry out. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing hall , Dragging of transformers tank from the repairing hall to washing area and its complete washing, cleaning, removing of rust and carbon etc. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out completely dried empty tank after painting to repairing hall. , Taking out core and coils assembly from the OVEN and shifting to repairing hall. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free. , Reconditioning of L.V leg coils strips including removing of old double paper covering and cleaning of strip than providing double paper covering , Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one. , Reconditioning of old damaged H.V. leg coils wire by removing old Double paper covering, cleaning of wire and providing new DPC insulation etc. , Making of H.V leg coils from reconditioned/new DPC wire of same size No. of turns and dimensions as old one. , Assembly of core, channel (dully painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc. , Shifting and keeping the assembled core & coil etc. in OVEN from the repairing area , Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out empty tank after painting to assembly area. , Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint. , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work.
Contract Date: Ref. Documents Contract Value : 56.08 Lakh
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 61,360
Boards / Undertakings / PSU No of Bidders 17
Contract Date: Ref. Documents Contract Value : 3.05 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
6.
Power #11346816 AOC
Bids Are invited for Handling and Dragging of Transformer from stacking yard to repairing hall with accessories. , Cutting/Opening of top cover plates & fitting of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free. , Reconditioning/ Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one. , Reconditioning/Making of H.V leg coils from new DPC or SE wire of same size and No. of turns and dimensions as old one. , Assembly of core, channel (duly painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing area. , Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out empty tank after painting to assembly area. , Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with super enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Unique number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and its cleaning. , Dismantling of Shell Core and coil assembly. Removing of HV and LV Leg coils for assessing its reuse, reuse of major insulating material if possible, checking and recording of physical dimensions of coil. , Making of complete HV & LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled/DPC conductor/ Strip confirming to IS 1971 153 in place of old and damage coil. Alu.coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Shell Coil shall be supported between adjacent sections by insulations (flick Paper) Paper, spacers, beamers and other insulations. Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of , Assembly of Shell core (Three Limbs) coils and fitting of top and other parts. Replacement of insulation such as press board, craft paper, making support between adjacent section by insulating spacers and wrapping etc. shifting of repaired core coil assembly and placement inside the oven for proper dry out. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing hall , Dragging of transformers tank from the repairing hall to washing area and its complete washing, cleaning, removing of rust and carbon etc. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out completely dried empty tank after painting to repairing hall. , Taking out core and coils assembly from the OVEN and shifting to repairing hall. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work.
Contract Date: Ref. Documents Contract Value : 39.80 Lakh
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
7.
Educational and Research Institute #11346435 AOC
Tender for Procurement Of Mountaineering Equipment And Clothing , Mountaineering Equipment And Clothing , Wind Proof Jacket Imported Brand : Should Be A Reputed Brand Fabric Type : Tightly Woven Synthetic Fabrics Such As Nylon Or Polyester. Coating : Durable Water Repellent Wind Proof : Yes A High Wind-Resistance Rating, Breathability To Prevent Overheating Two-Way Stretch Fabric And Preformed Elbows For Freedom Of Movement. Pockets: Secured By Ykk Zippers To Keep Essentials Like Phones, Keys, And Maps Safe During Outdoor Activities. Ventilation Zips On The Sides To Help Improve Air Circulation. Neck Style : Hooded Neck Cuffs : Extended Cuffs With Hook And Loop Adjusment For Fit With Gloves Fit : Regular Gender : Men Size Required : M/L/Xl/Xxl , Wind Proof Trouser Imported Brand : Should Be A Reputed Brand Fabric Type : Tightly Woven Synthetic Fabrics Such As Nylon Or Polyester. Coating : Durable Water Repellent Wind Proof : Yes Water Proof :Yes A High Wind-Resistance Rating, Breathability To Prevent Overheating Elasticated Waistbands For Adjustability. Two-Way Stretch Fabric And Preformed Knees For Freedom Of Movement. Pockets: Secured By Ykk Zippers To Keep Essentials Like Phones, Keys, And Maps Safe During Outdoor Activities. Ventilation Zips On The Sides To Help Improve Air Circulation. Fit : Regular Gender : Men Size Required : M/L/Xl/Xxl , Trekking Shoes Imported Brand : Should Be A Reputed Brand Closure Type : Lace-Up Comfort Collar: Soft Collar To Protect The Ankle With An Easy-Fit Spoiler That Facilitates The Fit Waterproof And Breathable Gore-Tex® Extended Comfort Membrane Lining Rear Stabilizing Heel For Perfect Control Over The Traverses Frixion™ White Sole In Soft Xf Compound With Pronounced Trail Bite Heel For Better Downhill Braking Sizes Required : 6-10 , Sleeping Bag Feather Imported Brand : Should Be A Reputed Brand Shape : Tapered Mummy Outer Material : Nylon Insulation: Down Feather Temperature : -10 Degree To -20 Degree Elongated Zip Pullers For Easy Zipping And Unzipping, Velcro Lock Mechanism To Avoid The Zip To Run Free While Inside The Sleeping Bag Zip : Ykk Weight : 1500-2000 Gm Fit : Regular Gender : Men Length : 210-220 Cm , Jacket Feather Imported Outer Material : Nylon Insulation : Down Feather Neck Style : Hooded Neck Pattern : Solid Operating Temperature :-10 Degree To -20 Degree Velcro-Over-Zipper Seal & Adjustable Cuffs Cuffs : Snug Stretch Cuffs To Seal In The Heat Zip (All) : Ykk Pocket : Double Side Pocket Weight : 400-600 Gm Fit : Regular Gender : Men Sizes Required : M/L/Xl/Xxl , Sunglasses Imported Brand : Should Have A Reputed Brand Uv Protection: Block 100% Of Uva And Uvb Rays Polarization : Reducing Glare From Flat Surfaces Like Water, Snow, Or Roads. Gender : Men Lens : Polycarbonate Lens Sun Protected : 100% Frame : Premium Light Weight , Thermal Suit Material : Polyster (Light Weight) Fit Type : Compression Sleeves : Full Neck Style : Crew Neck Fabric Stretch : High Closure Type : Pull On Sizes Required : M/L/Xl/Xxl , Socks Material : Fabric 72% Wool, 28% Polyamide Cushioned Sole, Toe & Heel Fabric Stretch : High Fit Type : Regular High Ankle Socks , Wind Proof Suit For Cook (Indian) Fabric Type : Tightly Woven Synthetic Fabrics Such As Nylon Or Polyester. Coating : Durable Water Repellent A High Wind-Resistance Rating, Breathability To Prevent Overheating Two-Way Stretch Fabric And Preformed Elbows And Knees For Freedom Of Movement. Pockets: Secured By Zippers To Keep Essentials Like Phones, Keys, And Maps Safe During Outdoor Activities. Ventilation Zips On The Sides To Help Improve Air Circulation. Zip : Ykk Logo On Front (Left Side) : Yes (Nehru Institute Of Mountaineering Logo) Neck Style : Hooded Neck Sizes Required : M/L/Xl , Trekking T-Shirt Half Sleeves Fabric : Polyester / Nylon (Synthetics) Sleeves : Half 4-Way Stretch: Fabrics Containing A Small Amount Of Elastane (Spandex) Allow For Optimal Mobility On Steep Inclines And Rocky Terrain. Ergonomic / Active Fit : Tailored For Freedom Of Movement Without Restricting Arms Or Shoulders. Flatlock Seams: Stitched Flat Against The Fabric To Reduce Friction And Eliminate Skin Irritation When Wearing A Heavy Backpack. Ventilation/Mesh Zones: Strategically Placed Mesh Panels Along The Sides, Back, Or Underarms To Enhance Air Circulation And Prevent Overheating. Anti-Microbial Treatment: Special Treatments To Prevent The Build-Up Of Sweat Odors During Multi-Day Hikes Gsm : 150 Gsm To 200 Gsm Size Required : M/L/Xl/Xxl , Trekking T-Shirt Full Sleeves Fabric : Polyester / Nylon (Synthetics) Sleeves : Full 4-Way Stretch: Fabrics Containing A Small Amount Of Elastane (Spandex) Allow For Optimal Mobility On Steep Inclines And Rocky Terrain. Ergonomic / Active Fit : Tailored For Freedom Of Movement Without Restricting Arms Or Shoulders. Flatlock Seams: Stitched Flat Against The Fabric To Reduce Friction And Eliminate Skin Irritation When Wearing A Heavy Backpack. Ventilation/Mesh Zones: Strategically Placed Mesh Panels Along The Sides, Back, Or Underarms To Enhance Air Circulation And Prevent Overheating. Anti-Microbial Treatment: Special Treatments To Prevent The Build-Up Of Sweat Odors During Multi-Day Hikes Gsm : 150 Gsm To 200 Gsm , Trekking Pant Imported Lightweight, Quick-Drying, And Breathable Fabrics : Synthetic (Polyamide Or Nylon), Polyster Elastane : 10-15% Elastane (Spandex) For 4-Way Stretch Water Repellent : Yes Reinforcements: Panels On Knees And Seat Made Of High-Denier Weave Or Cordura For Durability Against Rocks. Breathability: High Air Permeability To Prevent Overheating During Steep Ascents. Pockets: 3 To 4 Secure Pockets Waistband: An Elastic Or Partial-Elastic Waist With Belt Loops Sizes Required : M/L/Xl/Xxl , Knapsacks Imported Material : Nylon/Polyster Capacity : 40-50L. Gender : Men Zippers : Ykk Frame & Support: Includes Foam Padding, Airflow Mesh Channels, And Internal Frames (Aluminum/Plastic Stays) For Weight Distribution. Exterior : Waist Belt, Compression Straps, Gear Loops , Wind Proof Jacket Indian Fabric Type : Tightly Woven Synthetic Fabrics Such As Nylon Or Polyester. Coating : Durable Water Repellent A High Wind-Resistance Rating, Breathability To Prevent Overheating Two-Way Stretch Fabric And Preformed Elbows For Freedom Of Movement. Pockets: Secured By Zippers To Keep Essentials Like Phones, Keys, And Maps Safe During Outdoor Activities. Ventilation Zips On The Sides To Help Improve Air Circulation. Zip : Ykk Logo On Front (Left Side) : Yes (Nehru Institute Of Mountaineering Logo) Neck Style : Hooded Neck Size Required : S/M/L/Xl/Xxl , Wind Proof Trouser Indian Fabric Type : Tightly Woven Synthetic Fabrics Such As Nylon Or Polyester. Coating : Durable Water Repellent A High Wind-Resistance Rating, Breathability To Prevent Overheating Elasticated Waistbands For Adjustability. Two-Way Stretch Fabric And Preformed Knees For Freedom Of Movement. Pockets: Secured By Zippers To Keep Essentials Like Phones, Keys, And Maps Safe During Outdoor Activities. Ventilation Zips On The Sides To Help Improve Air Circulation. Zip : Ykk Size Required : S/M/L/Xl/Xxl , Sleeping Bag Feather Indian Shape : Mummy Type Outer Material : Nylon Inner Material : Feather Temperature : -10 Degree To -20 Degree Extra Padding Over The Chest To Increase Heat Retention And Below The Head To Provide Comfort Elongated Zip Pullers For Easy Zipping And Unzipping, Velcro Lock Mechanism To Avoid The Zip To Run Free While Inside The Sleeping Bag Zip : Ykk , Jacket Feather Indian Outer Material : Nylon Inner Material : Feather Neck Style : Hooded Neck Pattern : Solid Operating Temperature :-10 Degree To -20 Degree Velcro-Over-Zipper Seal & Adjustable Cuffs Zip (All) : Ykk Pocket : Double Side Pocket Logo : Yes (Nehru Institute Of Mountaineering Logo) , Gaiters Nylon Material : Soft Polyester Cotton Fabric Lining. Full Coverage Around The Leg High-Quality Full-Length Zip With Stiffener Under The Overlap To Ensure The Gaiter Does Not Ride Down During Use. Adjustable Boot Strap For Versatile Fit To Work- Wear Shoes. Waterproof : 100% , Rope Fixed Nylon 10 Mm (Pp Rope) Material : Nylon Colour : Yellow Versatile: Rope Should Be Suitable For Indoor And Outdoor Use Durable Construction : Made From High-Quality Nylon Material, Ensuring Long-Lasting Strength And Resistance To Wear And Tear Easy Installation
Contract Date: Jul 01, 2026 Contract Value : 41.68 Lakh
Government Departments No of Bidders 4
Uttarakhand View Result →
10.
Power #11338480 AOC
Bids Are invited for Handling and Dragging of Transformer from stacking yard to repairing hall with accessories. , Cutting/Opening of top cover plates & fitting of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free. , Reconditioning/ Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one. , Reconditioning/Making of H.V leg coils from new DPC or SE wire of same size and No. of turns and dimensions as old one. , Assembly of core, channel (duly painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing area. , Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out empty tank after painting to assembly area. , Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present , Spray painting of transformer tank from outside with super enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Unique number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and its cleaning. , Dismantling of Shell Core and coil assembly. Removing of HV and LV Leg coils for assessing its reuse, reuse of major insulating material if possible, checking and recording of physical dimensions of coil. , Making of complete HV & LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled/DPC conductor/ Strip confirming to IS 1971 153 in place of old and damage coil. Alu.coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Shell Coil shall be supported between adjacent sections by insulations (flick Paper) Paper, spacers, beamers and other insulations. Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of , Assembly of Shell core (Three Limbs) coils and fitting of top and other parts. Replacement of insulation such as press board, craft paper, making support between adjacent section by insulating spacers and wrapping etc. shifting of repaired core coil assembly and placement inside the oven for proper dry out. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing hall , Dragging of transformers tank from the repairing hall to washing area and its complete washing, cleaning, removing of rust and carbon etc. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out completely dried empty tank after painting to repairing hall. , Taking out core and coils assembly from the OVEN and shifting to repairing hall. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present. , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free. , Reconditioning of L.V leg coils strips including removing of old double paper covering and cleaning of strip than providing double paper covering , Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one. , Reconditioning of old damaged H.V. leg coils wire by removing old Double paper covering, cleaning of wire and providing new DPC insulation etc. , Making of H.V leg coils from reconditioned/new DPC wire of same size No. of turns and dimensions as old one. , Assembly of core, channel (dully painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc. , Shifting and keeping the assembled core & coil etc. in OVEN from the repairing area , Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out empty tank after painting to assembly area. , Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil. , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint. , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work. , Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories , Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly with the help of pneumatic tools , Dismantling of core & coil Assembly and its cleaning. , Dismantling of Shell Core and coil assembly. Removing of HV and LV Leg coils for assessing its reuse, reuse of major insulating material if possible, checking and recording of physical dimensions of coil. , Making of complete HV & LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled/DPC conductor/ Strip confirming to IS 1971 153 in place of old and damage coil. Alu.coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Shell Coil shall be supported between adjacent sections by insulations (flick Paper) Paper, spacers, beamers and other insulations. Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of , Assembly of Shell core (Three Limbs) coils and fitting of top and other parts. Replacement of insulation such as press board, craft paper, making support between adjacent section by insulating spacers and wrapping etc. shifting of repaired core coil assembly and placement inside the oven for proper dry out. , Shifting and keeping the assembled core& coil etc. in OVEN from the repairing hall , Dragging of transformers tank from the repairing hall to washing area and its complete washing, cleaning, removing of rust and carbon etc. , Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage. , Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint. , Dragging/shifting out completely dried empty tank after painting to repairing hall. , Taking out core and coils assembly from the OVEN and shifting to repairing hall. , Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer with the help of pneumatic tools and filling of oil, along with bringing oil gauge in working condition for transformers in which oil gauge cast iron and nut bolts are present. , Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint , Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place. , Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair , Package rate per transformer of supply item to be provided by the Contractor for repairing of transformer. Details of supply items are annexed hereto. , Making of broken delta/Star connection with suitable size of Alu. Ferrule/soldering the joint with suitable brazing rod including all associated work. , Making of broken HV/LV lead connection with suitable size of Alu. Ferrule including all associated work.
Contract Date: Ref. Documents Contract Value : 1.27 Crore
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
12.
Educational and Research Institute #11308092 Price Bid
Tender for Purchase Of Lab Equipments For Ice Dept , Purchase Of Lab Equipments For Ice Dept , I/P And P/I Converter (Iemcode:G002) • I/P Converter:(4-20) Ma To (3-15) Psi Conversion. • P/I Converter:(3-15) Psi To (4-20) Ma Conversion. • Air Filter Regulator (Afr):20 Psi Regulated Air Supply. • Built-In Current Source. • 3½ Digit Led Display For Process Indication. • Power Supply: 230 V Ac, 50 Hz. • • Mounting:Bench-Top / Panel-Mounted Trainer Configuration. , Level Measurement Using Float And Sight Glass Indicator- Itemcode: G005 Specifications: • Sight Glass Level Indicator. • Float Type Level Indicator. • Power Supply:230 V Ac, 50 Hz. • Monoblock Pump:0.5 Hp / 1 Hp. • Sump Tank. , 8051Develop Ment Board With Usb/Rs 232 Cable To Connect With Computer (Item Code: G008) Specifications: • Communication Interface:Usb / Rs-232. • On-Board Facilities:8 Output Leds,8 Input Switches,Ldr,Reed Switch,8-Bit Adc,8-Bit Dac. • Display Interfaces:Seven-Segment Display,16 × 2 Lcd Interface. • Motor Interfacing:Stepper Motor With Driver,Dc Motor With H-Bridge Driver , 8 Bit Adc/Dac Interface Board (Item Code: G009) Specifications: •Thermistor / Lm35 Input In One Channel. • Variable Input (0-5) V In Another Channel. • 8 Leds For Digital Output Indication.. • Necessary Control Signals Provided For Adc0809. • 8-Bit Dac Using Dac0808. • 8-Bit Digital Input From Controller. • Single-Channel Dac Output:(0-10) V. • Power Supply:±12 V Or ±15 V For Analog Circuitry , Water Level Measurement Trainer Kit Using Capacitive Type Transducer (Item Code: G020) • Tabletop Model With Transparent Acrylic Tank Of Approximately 50 Cm Height. • Capacitive Type Level Sensor For Continuous Level Measurement. • Sensor Output: (4-20) Ma And/Or (0-5) V With Built-In Signal Conditioning. • Vertical Pump For Water Circulation From Sump To Tank. • Flow Control Valve, Overflow, And Drainage Arrangement. • Digital Display For Water Level Indication In Cm. • Power Supply: 230 V Ac, 50 Hz, Single Phase. • In-Built Regulated Dc Power Supply For Sensor And Control Circuit. • Mounted On Powder-Coated Ms Frame For Laboratory Use. • Suitable For Calibration And Study Of Capacitive Level Measurement. , Flow Measurement Using Electromagn Etic Flow Meter(Item Code: G021) Specifications: • Medium: Water (Salt Water / Bore Well Water). • Electromagnetic Flow Measurement: Instantaneous Flow Rate And Totalized Flow Indication. • Electromagnetic Flow Meter: Integral Mounted Type. • Power Supply: 90-260 V Ac, 50 Hz. • Minimum Media Conductivity: 15 Μs/Cm. • Flow Rate Unit: M³/Hr. • Operating Pressure: Up To 10 Kg/Cm². • Electrode Material: Ss-304 / Ss-316 / Ss 316L. • Lining Material: Ptfe / Neoprene / Hard Rubber / Pfa. • Line Size: 15 Nb - 25 Nb. • Flow Range: 0.1-10 M³/Hr. • Connection Type: Flanged. • Display: Digital Indication For Flow Rate And Totalized Flow. • Water Pump: Submersible Type, 230 V Ac, 50 Hz. • Water Tank: Approximately 20-25 Liters Capacity. • Flow Control Valve Provided. • Drain Valve And Overflow Arrangement Provided. • Mounted On Powder-Coated Ms Frame Suitable For Laboratory Use.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
17.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
18.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
19.
Housing Urban and Rular Development #11150955 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Repair And Servicing Of Ambulence Trax (Force Motors ) Bearing Regestration No. Jk02dj-0133. Mhdj/E-Nit 06 Of 2026-27 Dated: 13.04.2026 Due : 23.04.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Repair Of Ambulance Trax Force Motor By Way Of Top Overhauling Of Engine And Repair Of Air Conditionong Sysytem .The Job Includes Dismantling The Cylinder Head And All Top-End Components Such As The Head Gasket, Valves, Valve Seats, Valve Springs, Rocker Arms, Push Rods, And Injectors. The Job Includes Complete Decarbonization Of The Cylinder Head, Pistons, And Intake/Exhaust Passages, Along With Machining Tasks Like Head Facing And Valve Seat Cutting Or Grinding As Required. Worn Parts Such As The Head Gasket, Valve Stem Seals, Manifold Gaskets, Injector Washers, And Other Consumables Are Replaced. The Cylinder Head Is Then Reassembled Using Proper Torque Settings, Valve Clearances Are Adjusted, And All Fuel And Coolant Connections Are Restored. After Reassembly, The Engine Is Tested For Smooth Starting, Proper Compression, Reduced Smoke, And Leakage-Free Operation, Ensuring Improved Performance, Better Mileage, And Reliable Running Of The Vehicle.The Job Also Includes Air-Conditioning Repair Involves Checking The Compressor, Condenser, Evaporator, And Refrigerant Lines For Faults Or Leaks, Replacing Damaged Parts, Vacuuming And Recharging The System With Gas, Cleaning Filters And Coils, And Finally Testing The Cooling Performance To Ensure Smooth And Efficient Ac Operation.The Complete Job Includes Cost Of Labour , Tool And Tackles Charges, Material Charges And All Kind Of Taxes. , Repair To Ambulance Trax Force Motors By Way Of Replacemnet Of Radiator The Job Includes Draining The Old Coolant From The System, Disconnecting The Upper And Lower Radiator Hoses, Coolant Reservoir Pipe, Fan Shroud, And Any Attached Sensors Or Transmission Cooling Lines . The Old Radiator Is Then Unbolted And Carefully Removed, And The Mounting Area Is Cleaned To Remove Dirt And Rust. Before Installing The New Radiator, All Hoses, Clamps, And The Thermostat Are Replaced . The New Radiator Is Fitted Securely With Proper Alignment, And All Connections Are Restored, Ensuring There Are No Loose Fittings. Fresh Coolant Is Added In The Correct Mixture, And The System Is Vacuumised To Remove Trapped Air. After Reassembly, The Engine Is Started And Brought To Operating Temperature To Check For Coolant Circulation, Proper Fan Operation, Stable Temperature Reading, And Absence Of Leaks. The Process Ensures The Cooling System Functions Efficiently And Prevents Engine Over Heating.The Complete Job Includes Cost Of Labour, Tool And Tackles Charges, Material Charges And All Kind Of Taxes. , Repair To Ambulance Force Trax By Way Of Replacement Of Clutch Plate Pressure Plate And Clutch Bearing . The Job Includes Removing The Gearbox To Access The Clutch Assembly And Restoring Smooth Power Transmission Between The Engine And Drivetrain. The Job Includes Disconnecting The Battery, Removing The Propeller Shaft , Detaching Sensors, Linkages, The Clutch Cable Or Hydraulic Line, And Unbolting The Gearbox From The Engine. Once The Gearbox Is Lowered The Old Clutch Assembly Is Removed From The Flywheel, And The Flywheel Surface Is Checked For Heat Spots Or Uneven Wear; It Is Resurfaced . A New Clutch Plate, Pressure Plate, And Clutch Bearing/Release Bearings Are Installed With Proper Alignment Using A Clutch Alignment Tool. The Gearbox Is Then Refitted, All Connections And Mountings Are Restored, And The Clutch Pedal Hydraulic System Is Adjusted For Proper Operation. Finally, The Vehicle Is Test-Driven To Ensure Smooth Gear Shifting, Proper Clutch Engagement, And Vibration-Free Performance.The Complete Job Includes Cost Of Labour, Tool And Tackles Charges, Material Charges And All Kind Of Taxes. , Complete Servicing Of Ambulence (Force Mototrs ) Bearing Regestration No. Jk02dj-0133 By Way Of Draining The Old Engine Oil And Filling Fresh The Engine Oil -6.5 Litres, Replacing The Oil Filter-1 No., Fuel Filter -01 No. Air Filter-01 No., Gear Oil -3 Ltr, Diffrential Oil-2 Ltrs , Power Streering Oil -1 Ltrs, Diesel Exhuast Fluid-20 Ltrs, Brake Fluid-200 Ml .The Job Also Includes Wheel Alignment. The Job Includes Cheking Charging Sysytem , Battery Life , Coolant Hoses, Suspension Components, Check Steering Component Innner/Outer Tie Rods, Grease And Lubricant Components,Check For Proper Operation Of All Lights, Check Radiator Fan Belt.The Job Includes Complete Cleaning And Washing Of Vehicle.The Complete Job Includes Complete Testing Of Engine After Sevicing. The Complete Job Includes Cost Of Labour For Complete Servicing , Tool And Tackles Charges, Material Charges And All Kind Of Taxes. Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
20.
Banking and Finance #11145714 AOC
Bids Are invited for Supply,Installation,Testing and Commissioning - Supply,Installation,Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. ISEER value must be minimum of 5.6.The AC must have 2026 manufacturing year The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating AC Make,-Hitachi/Voltas/Bluestar/Daikin /LG/Panasonic. , Additional copper refrigerant Pipe and additional cable - Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI - WALL SPLIT with addtional necessary cables. , Additional Drain Pipe - Supply and fixing of duly insulated 25mm UPVC additional drain pipe , Outdoor Stand - Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC. , Dismantling - Dismantling of old Air conditioners Total Quantity : 805
Contract Date: Ref. Documents Contract Value : 16.53 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 3.08 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
23.
Health and Family Welfare #11073758 Technical Bid
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J‟ Or „L‟ Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
25.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
26.
Educational and Research Institute #10970079 AOC
Tender for Supply, Assembly, Installation And Commissioning Of Anti-Corrosion Plating And Testing Centre , Process Tank , Supply Of Pp Tank Size As Per Tsc Ms Reinforcment Box Pipe 48*48*3 Mm Thickness Tank Size- L-400 * W-600 * H-900 * Thk-12Mm. (Rochlene/ Simona Germany) , Pp Barrel Made With 10 Mm Thickness Pp Sheet (Simona Make) With Self-Rotation Gear Box Motor Arrangement. Hole Dia. 2Mm. Loading Capacity 3~5 Kg. , Igbt Rectifier , Supply Of Rectifiers Having Rating 12-Volt -150 Ampere , Copper Part , Copper Pipe Dia. 25 Mm Thickness 3 Mm For Anode Bar Length- 600 Mm. , Flexible Single Core Dc Copper Cable 120 Sq.Mm For Anode And Cathode Connection Rectifier To Tank , Copper Tin Plated Thimble 120 Sq.Mm , Ss Hardware For Busbar Connection , Heater Ss And Teflon , Supply Of Ss-304 Heater For 3 Kw Rating Each Soak, Anodic With Level Sensor. , Supply Of Teflon Heater Having A Rating Of 3 Kw Each As Per Tsc With Level Sensor , Temp. Controller Box With Pt-100 Sensor, Tic, Timer And Buzzer , Filter , Pp Plate Type Filter Unit With Magnetic Pump (6,000 Capacity) , Upvc Pipeline With Valve And Fitting For Filter Pipeline , Fume Exhaust System , Supply Of Pp Frp Blower Having Capacity Of 3000 Cfm Complete With Base Frame, 5 Hp Motor, Belt, Guard And Anti-Vibration Pad. , Supply Of Ppgl Frp Scrubber Having Capacity Of 3000 Cfm Complete Pp Pump Inlet/Outlet Connection, Drain Connection With Drain Valve, Dia. - 1000 Mm, Height- 1800 Mm, Thickness - 8 Mm , Supply Of Pvc 5 Mm Thick Inlet And Outlet Ducting Having Diameter Of 250 Mm , Cooling System For Zinc Tank , Air Cooled Chilling Plant Having Capacity 1 Ton With Circulation Pump , Supply Of Titanium Cooing Coil For Acid Zinc And Acid Barrel Tank , Supply Of Ms Cooing Coil For Alkaline Zinc Plating Tank , Supply Of Ss-316 Cooing Coil For Zinc Nickel Plating Tank , Interconnecting Auto Control Pipeline Moc Upvc Chilling Plant To Cooling Coil , Titanium Basket And Anode Plate , Titanium Basket Made With 1.2 Mm Thickness Pe
Contract Date: May 16, 2026 Contract Value : 41.11 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
27.
Public Administrative Department #10902304 Technical Bid
Tender for Supply Of Big And Small Almirah , The Successful Bidder Will Provide Goods And Article As Per Terms And Conditions Of Open Tender. , Big Almirah Specifications (Visual Analysis) 1. Type: Full-Height Metal Storage Almirah 2-Door Unit With Handle And Lock 2. Material: Made Of Powder-Coated Steel (Gray Finish) Likely To Be Rust-Resistant And Durable For Office Or Industrial Use 3. Dimensions (Estimates Based On Standard Size): Height: Approx. 6.5 Feet (78 Inches) Width: Approx. 3 Feet (36 Inches) Depth: Approx. 1.58 Feet (19 Inches) 4. Compartments: 5 Total Compartments (4 Adjustable Shelves + Base Space) Removable/Adjustable Shelf Design, Ideal For Files Or Tools 5. Locking System: Central Locking Mechanism (One Lock For Both Doors) Chrome-Plated Handle With Integrated Keyhole 6. Legs/Base: Elevated With 4 Metal Legs - Helps Prevent Moisture Contact From Floor Offers Easier Cleaning And Better Air Circulation Underneath 7. Color & Finish: Matte Or Semi-Gloss Gray Powder-Coated Finish Scratch And Corrosion Resistant Surface (Industrial-Grade) 8. With 5 Partitions + 4 Shelves + 18 Gauge + 40 Kg Single Shelf Load Capacity Total Weight Of Big Almirah Is 77 Kg Per Pc. , Small Almirah Specifications (Visual Analysis) 1. Type: Full-Height Metal Storage Almirah 2-Door Unit With Handle And Lock 2. Material: Made Of Powder-Coated Steel (Gray Finish) Likely To Be Rust-Resistant And Durable For Office Or Industrial Use 3. Dimensions (Estimates Based On Standard Size): Height: Approx. 4 Feet (48 Inches) Width: Approx. 2.5 Feet (30 Inches) Depth: Approx. 1.5 Feet (18 Inches) 4. Compartments: 4 Total Compartments (3 Adjustable Shelves + Base Space) Removable/Adjustable Shelf Design, Ideal For Files Or Tools 5. Locking System: Central Locking Mechanism (One Lock For Both Doors) Chrome-Plated Handle With Integrated Keyhole 6. Legs/Base: Elevated With 4 Metal Legs - Helps Prevent Moisture Contact From Floor Offers Easier Cleaning And Better Air Circulation Underneath 7. Color & Finish: Matte Or Semi-Gloss Gray Powder-Coated Finish Scratch And Corrosion Resistant Surface (Industrial-Grade) 8. With 4 Partitions + 3 Shelves + 18 Gauge + 40 Kg Single Shelf Load Capacity Total Weight Of Small Almirah Is 48 Kg Per Pc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
28.
Banking and Finance #10900929 AOC
Bids Are invited for SITC OF HI WALL 1.0 TR SPLIT SYSTEMS AND BUYBACK OF HI WALL SPLIT AC - Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners 1.0 tr split ac complete with Indoor unit, Out door unit , surface or concealed copper Refrigerant piping with insulation closed cell elastomeric nitrile rubber tubular pipe section upto 3 Mtr IDU to ODU, copper power cable upto 3.5 Mtr IDU to ODU ic drain pipe R32 or R410 or R407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll or rotarycompressor. The system shall be able to deliver 100PERCENTAGE of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer warranty both compressor and Printed Circuit Board . Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission IEC 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS 1391 Part II 2023. The system shall be able to operate up to 50 Degree C out door ambient temperature. Buy Back of OLD AC Units on wherein whereas basis. , COPPER REFRIGERANT PIPING for 1.0 TR HI WALL SPLIT AC - Supplying, Installation, testing , commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class O tubular insulation or with Class O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia OD Soft drawn with tube thickness 1.2 mm and 12.7 mm dia OD Soft drawn with tube thickness 1.2 mm for 1.0 TR HI WALL SPLIT along with power cable of required size. , DRAIN PIPE - Supply and fixing of duly insulated 25mm UPVC drain pipe , OUTDOOR STAND for 1.0 TR HI-WALL SPLIT AC - Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.0 TR Hi-Wall Split AC. , FIXING OF REMOTE HOLDER IN THE WALL - Supplying and Installation of remote holder on the wall in the each room and making good all the damage . Total Quantity : 178
Contract Date: Ref. Documents Contract Value : 5.53 Lakh
Government Departments No of Bidders 5
West Bengal View Result →
29.
Power #10900203 AOC
Bids Are Invited For Round The Clock Up-Keeping And Maintenance Of Turbine And Its Auxiliaries Of 9,10 And 11 - Round The Clock Up Keeping And Maintenance Of Turbine And Its Auxiliaries & Round The Clock Up-Keeping And Maintenance Of Boiler Feed Pumps, Condensate Pumps And Other Small Pumps Of Unit 9,10 And 11. One Job Means Round The Clock In All Three Shifts Per Day For One Month For Three Units , Changing Of Gasket Of Esv , Chng.Transfer Pipe Gasket Of Hpc Flange Or Ipc Flange , Complete Oh Of Control Valve Of Hpc Or Ipc Or Changing Of Valves , Complete Oh Of Barring Gear. , Open Cover Of T.G. Brg 1 Or 2 Or 3 Or 4 , Chng. Brg Of Roller Of Cont Valve Hpc , Insp And Rect Of Fault Of Turbine Brg 1 Or 2 Or 3 , Insp And Rect Of Fault Of Turbine Brg 4 Or 5 , Insp And Rect Of Fault Of Turbine Brg 6 Or 7 , Chng. Of Bush In Control Valve. , Re-Visioning Of Cam Shaft Of Hpc Or Ipc , Re-Visioning Of Cont Valve Column Of Hpc Or Ipc , Chng Thrust Or Surge Pad Of Brg No. 2 , Re-Visioning Of E.G.P.V. , Cleaning And Check Of Lkg Of Oil Clr Of Tur , Alignment Of Motor Of Barring Gear. , Chng. Of Thrust Brg Or Gear Coupling Of Mop , Oh Of Pilot Of Servo Motor Of Esv Or Iv. , Replacement Of Lpc Diaphragm. , Complete Oh Of Cvsm. , Complete Oh Of Servomotor Of E.S.V Or I.V. , Re-Visioning Of Other Pilot Valves. , Cleaning Of Filters Of Main Oil Tank , Oh Of Feedback Pilot Valve Of Cvsm , Removing Barring Gear For Diff, Exp. , Rep Of Def Oil Seal Or Brg Of Barring Gear. , Rep Of Def Pinion Brg. Of Barring Gear. , Oh Of Main Ejector Or Attending Leakage , Checking Of Tube Leakage Of Condenser , Cleaning Of Condenser , Patch Welding In L.P. Pipe Up To 50 Mm Or Cut And Weld For Joint Of L.P. Pipe51 To 100 Mm , Patch Welding In L.P. Pipe Above 100 Mm Or Fab Of Bend From L.P. Pipe51 To 100 Mm , Fab Of Bend From L.P. Pipeup To 50 Mm Or Cut And Weld For Joint Of L.P. Pipe101 To 150 Mm , Fab Of Bend From L.P. Pipe101 To 150 Mm , Fab Of Bend From L.P. Pipe151 To 200 Mm , Fabrication Of Bend Size- 25 To 50Mm , Cut And Weld For Joint Of L.P.Pipe Upto 50Mm Or Fabrication Of Bend Size- 51To 60Mm , Cut And Weld For Joint Of L.P.Pipe151 To 200Mm , Attend Flange Or Bonnet Lkg Of Hp Valve Or Hp Pipe Upto50 , Attend Flange Or Bonnet Lkg Of Hp Valve Or Hp Pipe 51 To 100 , Attend Flange Or Bonnet Lkg Of Hp Valve Or Hp Pipe101 To 150 , Attend Flange Or Bonnet Lkg Of Hp Valve Or Hp Pipe151 To 200 , Oh Of By Pass Valve Of Temp Control Line Or Patch Welding Work In The Condenser Or Hot Tightening Of Ejector , Clean Of Filter Of Tur Oil Or H2 Cooler Str , Oh Of Main Steam Line Valve I.E. V2 6 , Oh Of Feed Line Valve With By Pass Valve , Oh Of Nrv Of Extraction Line, Es-1 Or Es-2 Or Ipt Transfer Pipe Line Drain Valve , Oh Of Nrv Of Extraction Line,Es-8 Or Es-11 Or Oh Of Nrv Of Hp Drip Or Cep Disch Line , Oh Of Valve Cont.To Cond Dw-4 Or 38- 41 Or Ca-5 Or As-47 Or As-48 Valve , Oh Of Stm Throw Valve To Cond Or Iso Lph-2 , Oh Of Steam By Pass Valve V2-27 Or 15 Or V2-7 , Oh Of Extrac Valve I.E. Es-3 Or 4 Or 5 Or 6 Or 7 Or Oh Of Drip Line Gate Valve Hd-21Or 29 Or 30 Or 31 , Oh Of Fcnrv Or Isolating Valveof Lph-3 Or 4. , Oh Of Condensate Throw Off Valve To Cond , Rep Of Es-9 By H.P Welding Tech, , Rep Of V2-27 Or 15 By H.P Welding Tech, , Rep Of V2-38 Or 81-84 By H.P Welding Tech, , Oh Of Actuators Of Msv-L Or R , Oh Of Actuators Of Dw-4 Or 38- 41 Or Ca-5 Or Cst Makeup Valve Or Es-3 To7 Or Hd-21 Or Hd-29 To 31 Or As 47 Or 48 , Oh Of Actrs Of V2-38 Or 81-84 Or 27 Or 15 Or V2-7 Or Steam Iso Valve Lph-3 Or 4 , Oh Of Actrs Of Butterfly Valve , Oh And Re-Visioning Of Lph-2 To Lph-4 Or Gc-I Or Gc-Ii Or Lph-1A Or Lph-1B , Oh Of Gauge Glass Of Lph Or Gc Or Ejc Or Dea O Rcon , Tight. Of Flange Of Crh Or Gc-I Or Ii Or Lph , Overhauling Of Dss Of Aux., Prds-Ii , Overhauling Of Main Flash Tank , Overhauling Of Aux Flash Tank , Repair Or Replacement Of Broken Hanger. , Tightening Of Loose Hangers. , Attend The Flange Leakage Of Crh Line. , Serv Of Hydr. Brake Of Chit Or Gar Crane , Chk And Grs. Of Brg,Cplg,Chang Bush Of Bolt Or Serv Of Greep Brake Of Chit Or Garlic Crane Or Sevicing Servicing Of All The Wheel Of Garlic Or Chitram Crane And Plate - Chk And Grs. Of Brg,Cplg,Chang Bush Of Bolt Or Serv Of Greep Brake Of Chit Or Garlic Crane Or Sevicing Servicing Of All The Wheel Of Garlic/Chitram Crane And Plate , Oh Of Small Hook Of Chit Or Garlic Crane Or Oh Main Hook , Serv.Of All Gear Boxes Of Chit Or Gar Crane , Check And Clean Of Wire Rope Drum Or Bearing , Oh Of Dss Of Aux. Prds , Cut And Weld And Repl Of Lp Valve Up To 50 Mm , Cut And Weld And Rep Of L.P. Valve51 To 100Mm , Cut And Weld And Rep Of L.P.Valve101 To 150Mm , Oh Of Isolating Or Bypass Valve Of Pcv 5 Or 14 Or 17 , Oh Of Valve Contd To Dea At 13 Mtr V2-21 Or Cst Makup Valve , Oh Of Suc Valve Of Bfp Or Disch Valve Of Cep , Oh Of Suction Valve Of Cep Or Mc-18-25 Or 33 Or 37 Or Oh Of U Bend Valve , Fab Of Reducer For Hp Drip 218-80 Or 168-80 , Rep Of Reducer Of H.P Drip Line , Lph Drain Line Valve Hd-8 Or 9 Or 14-19 Or 20 , Check And Rect Of Internal Fault Of Dea , Blanking Of Crh Line For Reheater Ht , Rem Chocking Oil Drain Of Brg1 Or 2 Of Tur. , Rem Chocking Of Drain Of Cntg. Machine. , Repl Of Damaged Nrv Of Pcv-14 Or 17 Size200 , Repl Of Damaged Nrvof Feed Line Size-250 , Oh Of Butterfly Valve Of Condenser , Hot Tightening Of Cross Over Pipe , Oh Of Hp Heater And Attend Of Flange Lkg. , Attending The Shell Joint Of Hph , Attend The Spot Lkg Of Hph Shell Joint. , Oh Of Safety Valve Of Flange Or Stud Heatng Or Lp Heater Or Hp Heater Or Cbd Tank , Oh Of Safety Valve Of Warm Up Line , Oh Of Safety Valve Of Aux Prds Or Deaerator Or Oh Of Nrv Of Aux Rpds Heat Line To Fst , Oh Of Nrv V2-52 Or V2-53 Or V2-80 , Oh Of Nrv Of Re-Circulation Line Of Bfp Or Spindle Leak Off Line , Oh Of H.P. Valve And Nrv. , Oh Of H.P. Steam Drain Line Valve. , Rep Of Nrv Of Hph Drip To Deaerator , Welding Of Crack In Hph Or Crh Pipe Line , Fab Of Bend For Re-Circulation Line Or Oh Of Group Protection Valve I.E. Fw-1 , Fab Of Bend For Hph Drip Line Con To Dea , Fab Of Bend Of Lph Drip To Drip Pump Or Condenser , Rep Of Bend Of Hph Drip Line Con To Dea , Rep Of Bend Of Rc Line Con To Dea Or Oh Of Feed Pump Energy Absorber. , Rep Of Bend Of Lph Drip To Drip Pump Or Condenser , Cutting And Welding Of H.P. Valve 15 To 50Mm , Cutting And Welding Of H.P.Valve 51 To 100Mm , Cutting And Welding Of H.P.Valve101 To 300Mm Or Oh Of Pcv 10 , Rem Of Chocking Of Shell Or Coil Drn Of Hph , Ohof Lcv3-12 Or 15 Or Pcv5 Or 14 Or 16 Or 17 Tcv8 Or 10-12 , Cut Or Weld Of Joint Of H.P. Pipe15 To 50Mm , Cut Or Weld Of Joint Of H.P. Pipe51 To100mm , Fab Of Bend 63.5 X 5.5Mm With Jacketing , Overhauling Of L.P. Valve Or Lp Nrv , Overhauling Of Lp By Pass Valve. , Overhauling Of Hp By Pass Valve. , Overhauling Of Hp Or Lp By Pass Spray Valve , Changing Of Mech. Seal Bfp Booster Pumps De Or Nde , Re-Visioning And Checking Of Working Oil Or Lube Oil Cooler , Re-Visioning And Tube Leakage Sw , Re-Visioning And Checking Bcw Or Swc , Replacement Of Inside Stator Assy , Inspection Or Rectification Of Fault Of Bfp Nde Or De Bearing , Rectification Of Fault Of Bfp Motor Nde Or De Bearings , Complete Oh Of Drip Pump , Oh Of Cw Booster Pump Or H2 Gas Cooling Pump , Alignment Of Motor Of Cw Booster , Re-Adjustment Of Bearing , Inspection Of Fault Of Drip Pump , Overhauling Of Bcw Or Hw Or Sw Or Swc Pump , Overhauling Of Phosphate Dosing Pump , Oh Of Hydrazine Pumps Or Re-Visioning Of Suction Filter , Re-Visioning Of Thrustpad Of Bfp , Alignment Of B.F.P. With Hydraulic Cplg , Shifting Of Condensate Pump Without Modification , Shifting Of Condensate Pump2 With Modification , Fabrication Of Compensator Suction , Fitting Of Compensator In Suction Line , Inspection Of Fault Of Cep Bearing , Complete Overhauling Of Cep , Cleaning Of Strainer Of Cond. Pumps. , Replacement Of Bfp Lo Or Wo Or Sw Cooler , Overhauling Of Air Washer Blower , Overhauling Of Air Washer Pump , Tanks Cleaning , Cleaning Of Working Oil Cooler Of Bfp , Cleaning Of Lub Oil Cooler Of Bfp , Matching Of Thrust Collar , Replacement Of Aop Oil Seal , Replacement Of Damaged Coupling Bush , Replacement Of Damage Nipple Of Bfp , Priming Of Aop Or Attending Oil Leakage , Changing Of Plunger , Filling Gland In Phosphate Or Hydrazene , Cleaning Of Cooling Oil Line , Removal Of Chocking Of Bcw Line Of Cep , Cleaning Of Make Up Oil Storage Tank , Replacement Of Damage Flange , Alignment Of Motor Of Air Washer Pump Or Fan Or Sop , Alignment Of Ac Or Dc Lub Oil Pump , Replacement Of Bearing Of Hydr Coupling , Complete Oh Of Hydraulic Coupling , Replacement Or Re-Visioning Of Mop Or Aop , Revisioning And Checking Of Control Block Scoop Tube , Cleaning Of Cooling Line Of B.F.P.B Pu Or Drip Pumps , Re-Visioning And Checking Of Wire Mesh , Overhauling Of Boiler Feed Pump Upto Balancing Disc , Changing Of Mech. Seal Of Bfp-S.S , Changing Of Mech. Seal Of Bfp-D.E , Oh Of Boiler Feed Booster Pump , Alignment Of Motor Of Boiler Feed Booster , Alignment Of Motor Of Drip Pump , Alignment Of Motor Of H2 , Alignment Of Motor Of B.C.W. Or Hw Or Swc Or Sw Pump , Rectification Of Fault Of Bearings Of Bfp Booster , Oh Of Centrifuging Mc Pump , Straightening Of Condensate Pump Shaft , Replacement Of Drip Pump , Cleaning Of Filter Of Aop , Decoupling And Coupling Of Motor Of Cep Or Attending Gland Leakage Of Cep , Attending Gland Leakage Of Drip Pump , Cleaning Of Filters Of Phosphate Or Hydrazene , Replacement Of Damage Coupling Of Aop Or Cleaning Of Suction Filter Of Air Washer , Rectification Of Foundation Base Or Rectification Of Coupling Of Small Pump , Alignment Of Hydraulic Coupling , Re-Visioning Of Seal Water Cooler , Oh Of Osu Of Hp Or Lp System , Clean Of Bcw Cooing Line Of Bfp Bstr Or Chang Labyrinth Seal Of Bfp Motor Brg , Trans Of Spares From Csd To S Store Of Tmd-I , Loading And Unloding And Transp Of Material Of Tmd-Ii , Round The Clock Routine And Preventive Maintenance Works Of Turbine And Its Auxiliaries Of Unit No. 12, 13 And Cw Pump Total Quantity : 92218
Contract Date: Ref. Documents Contract Value : 2.65 Crore
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
31.
Drinking Water Supply and Sanitation #10812855 Price Bid
Tender For Procurement Of Hot Air Oven Under Cwa(W&S)-Ii Division. , Hot Air Oven Make: Aelius/ Thermo Fisherfisher/ Binder/ Thermic/ Carbolite//Yadadichi Or Any Djb Approved Make Desired Technical Specifications: Capacity:336 Litres (+ 5L) Dimensions (In Mm): Inner: 605X605x905mm (+ 20 Mm) Material Of Construction (Moc): • Inner Body: 304 Grade S. Steel Interior, Corrosion Resistant Long Life Operation Having Adjustable Shelves To Make More Space For Different Height. • Outer Body: Ms/ Gi Powder Coated • Insulation: Mineral Wool / Blanket Insulation To Keeps The Surface Of The Instruments From Not Being Burnt. • Heaters: Best Quality Coil Shaped Heaters Duly Embedded / Wound On The Sides & Bottom For Better Accuracy, Moc Of Heater Should Be Ferritic Iron-Chromium-Aluminium Alloy (Fecral Alloy) For High Temperatures. The Alloy Is Characterized By High Resistivity And Good Oxidation Resistance. • Shelves: Ss 304 (3 Number) • Instruments Should Be On Wheels For Easy Movement With Wheel Lock Facility Design:It Should Have Ventilation To Keep The Surface Of The Instrument From Being Not Been Burnt Even When The Instrument Maintained At High Temperature. Hardware:-Lock & Handle Material Zinc, Base Finish: Spc, Handle Finish: Black Pc With Key Hinges Material Zinc, Pin Material : Ss 304 Grade, Finish Stpc, Opening Angle: 180 Deg Temperature Range: Ambient To 250 °C Temperature Stability: ± 0.5°C Hot Air Blower: Silent, Heater: 2.5Kw (Embedded) Air Circulation: Uniform Air Movement & Improved Temperature Distribution Temperature Controller: • Hmi Display With Feather Screen Touch Digital Temperature Controller, • 7 Display • Continuous Display Of Temperature, Time, Day & Date Door Open Alarm, Hmi Display Of Data & Graph • Password Protected Operations, • Data Transfer Port: Usb Port • Data Log/Memory: • Door Open Alarm, • Programmable Safety Function: Temperature Over Warranty: 3 Years Minimum
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
32.
Drinking Water Supply and Sanitation #10812854 Price Bid
Tender For Procurement Of Bacteriological Incubator Under Cwa(W&S)-Ii Division. , Bacteriological Incubator Make: Aelius, Thermo Fisherfisher, Binder, Thermic, Carbolite, Yadadichi Or Any Djb Approved Make Desired Technical Specifications: Capacity:336 Litres (+ 5L) Dimensions (In Mm): Inner: 605X605x905mm (+ 20 Mm) Material Of Construction (Moc): • Inner Body: 304 Grade S. Steel Interior, Corrosion Resistant Long Life Operation Having Adjustable Shelves To Make More Space For Different Height. • Outer Body: Ms/ Gi Powder Coated • Insulation: Mineral Wool / Blanket Insulation To Keeps The Surface Of The Instruments From Not Being Burnt. • Heaters: Best Quality Coil Shaped Heaters Duly Embedded / Wound On The Sides & Bottom For Better Accuracy.Moc Of Heater Should Be Ferritic Iron-Chromium-Aluminium Alloy (Fecral Alloy) For High Temperatures. The Alloy Is Characterized By High Resistivity And Good Oxidation Resistance. • Shelves: Ss 304 (3 Number) • Toughened Glass Window • Instruments Should Be On Wheels For Easy Movement With Wheel Lock Facility Hardware:-Lock & Handle Material Zinc, Base Finish: Spc, Handle Finish: Black Pc With Key Hinges Material Zinc, Pin Material : Ss 304 Grade, Finish Stpc, Opening Angle: 180 Deg Temperature Range: Ambient To 70 °C Temperature Stability: ± 0.5°C Hot Air Blower: Silent, Heater: 1 Kw (Embedded) Air Circulation: Uniform Air Movement & Improved Temperature Distribution Temperature Controller: • Hmi Display With Feather Screen Touch Digital Temperature Controller, • 7 Display • Continuous Display Of Temperature, Time, Day & Date Door Open Alarm, Hmi Display Of Data & Graph • Password Protected Operations, • Data Transfer Port: Usb Port • Data Log/Memory: • Door Open Alarm, • Programmable, Safety Function: Temperature Over Warranty: 3 Yerars Minimum
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Chhattisgarh View Result →
34.
Drinking Water Supply and Sanitation #10784334 Price Bid
Tender For Renovation, Modernization And Special Repair Works At Gwd Jalore- Part (A): Civil Work: Grading roof for water proofing treatment with water proffing compound: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 2 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design 3 Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing. After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 4 Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 6 Interlocking Paver Blocks having 100 mm thickness in M- 50 grade concrete: Providing and Laying 100 mm thick cement concrete blocks of M-50 Grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds (Milled and manufactured in CSI diamond or CSI Nitro process for accuracy) on steel base plate of min 16 mm thick; Having Vibration and pressing action both together with the help of multiple synchronised vibrators. Power of hydraulic station should be minimum 50KW for compaction and cured in controlled chambers having humidity control and automated air circulation system) spreading 25mm thick sand underneath and filling joints with sand on existing W.B.M.base, as per IS15658:2006 and all materials shall conform to MoRTH Specification Clause 602. 7 Kerb Stones of 1200x300x150, 1000x450x150, 1000x600x150, 600x300x150 size (M-30):Providing and Laying cement concrete Kerb Stones of different sizes in M-30 grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds (Milled and manufactured in CSI diamond or CSI Nitro process for accuracy) on steel base plate of min 16 mm thick; Having Vibration and pressing action both together with the help of multiple synchronised vibrators. Power of hydraulic station should be minimum 50KW for compaction and cured in controlled chambers having humidity control and automated air circulation system) in position to the required line, level and curvature jointed with cement mortar 1:3 (1 Cement : 3 Coarse sand) including making of joints, drainage opening wherever required. 8 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 9 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick . 10 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 11 Renewing glass panes,with putty and nails wherever necessary: Float glass panes of thickness 4 mm 12 Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry: Size 100 x 75mm. 13 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure A : 35 mm thick: Commercial Veneer both side 14 Providing and applying Melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect: New Surface 15 Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete 16 Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. 17 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make: 75 mm dia 18 Part (B): Electrical Work: Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR: 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
36.
Defence #10756973 Price Bid
Purchase Of Medical Stores As Per Rfp , Medicines : , Bio-Composite Fenestrated Screw Dia, 7*20Mm (65% Plga, 20% Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 8*25Mm (65% Plga, 20% Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 9*30Mm (65% Plga, 20% Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 10*30Mm (65% Plga, Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 11*30Mm (65% Plga, Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 12*30Mm (65% Plga, Calcium Sulphate & 15% B-Tcp) , Bio-Composite Fenestrated Screw Dia, 10*30Mm (65% Plga, Calcium Sulphate & 15% B-Tcp) , Cannulated Retrograde Drill System For Creating Circular 8Mm Size Sockets For Acl/Pcl Reconstruction With All Inside Technique , Oxinium Knee Set , Made With Fabric Of Fully Absorbent And Impermeable To Fluids, Reinforced Or Field With An Additional Nonwoven Layer, Safe Barrier Effect Against Penetration By Fluids And Bacteria, High Tensile Strength And Very Low Linting. Use Of Raw Materials Free Of Natural Rubber Latex. Approved With Certified Test For, A. Resistance To Microbial Penetration Test Iso 22610 (Wet), Iso 22612 (Dry). , Made With Fabric Of Fully Absorbent And Impermeable To Fluids, Reinforced Or Field With An Additional Nonwoven Layer, Safe Barrier Effect Against Penetration By Fluids And Bacteria, High Tensile Strength And Very Low Linting. Use Of Raw Materials Free Of Natural Rubber Latex. Eu Ce Marked. En13795 Approved With Certified Test Fsmart Arthroscopy Set (33851) Made With Fabric Of Fully Absorbent And Impermeable To Fluids, Reinforced Or Field With An Additional Nonwoven Layer, Safe Barrier Effect Against Penetration By Fluids And Bacteria, High Tensile Strength And Very Low Linting. Use Of Raw Materials Free Of Natural Rubber Latex. Eu Ce Marked. Usfda Approved. En13795. Approved With Certified Test For, , Wraparound Surgical Gown Made Of Poly-Propylene 4 Layered (Smms) Fabric With Additional Fluid-Impermeable Breathable Reinforcements On The Front And Sleeve Area, Very Well Suited For Operations With Large Amount Of Fluid. Lightweight, Reliably Protects Against Bacteria And Fluids, Ensures Circulation Of Air, Heat And Water Vapour. => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
37.
Housing Urban and Rular Development #10729450 Price Bid
Tender for Drilling Of Borewell,Pumpset And Main Pipe Line (L-1560M) At Kalaignar Nagar St Colony In Thervoy Panchayat , Conducting Geophysical Survey And Transportation Charges Etc., , Drilling Of 12 Dia Vertical Borewell So As To Have A Finished Size Of 6 Dia Borewell In Boulder Area To Anyrequired Depth As Decided By The Twad Board Officers Including Transportation From One Place To Anothr Place With In Tamilnadu State By Direct Or Reverse Rotary Mud Circulation Method Using Contractors Rig Tools, Fuel, Labourers, Bentonite Mud And Water Required For Drilling At The Site Shown By The Twad Officers Including Construction Of Mud Pit Etc. Using Only Calyx Rigs.P202(Wd-W0840) 14F , Reaming From 150Mm Dia Pilot Bore To 300Mm Dia Bore Well P197(Wd-W0771)- 8F , Labour Charges For Inserting The Casing Pipe Assembly Slot(Or) Palin Pebbles Packing Charges P201(Wd-W0830 - 13A , Charges For Developing The Bore Well For The Entire Depth With Suitable Air Compressor As Directed By The Departmental Officers Including Conducting Yield Test In The Bore Well P201(Wd-W0833) 13B , Supply And Delivery Of 150Mm Dia Pvc Casing Pipe , A) 150Mm Dia Pvc Plain Casing Pipe (Per Mt) Cs P06(Wd-M0027) -1.1=1 , B) 150Mm Dia Pvc Slot Casing Pipe (Per Mt) Rs P06(Wd-M0029) - 1.1 = 3 , B) 160Mm Dia Pvc End Cap (Per Mt) P10(Wd-M0115) - 11 , Mottor For The Submersible Pumpset Etc.,75X100 P104(Wd-M1629) - 3.1(16 , Labour Charges For Errection The 5Hp Submersible Pumpset P204(Wd-M0871)-17C-I , 3Phase Panel Board P119(Wd-M1912)-11.1-5 , Supply And Delivery Of 4 Sq.Mm P124(Wd-M1975)-12.1-3 , Supply And Delivery Of 50Mm Gi Pipe P27(Wd-M0489)-5.0-6 , Supply And Delivery Of 50Mm Gi Cupling P32(Wd-M0596)-5.1B-3 , Supply And Delivery Of 50Mm Supporting Clamps With Nolt Mut P-32(Wd-M0617)-5.1B-24 , 165Mm Bore Well Cover Market Rate , 50Mm Gi Elbow P-32(Wd-M0594)-5.1B-1 , 50Mm Ci Flange Set With Bolt Nut Washer P-32(Wd-M0597)-5.1B-4 , 50Mm Hex Nipple P-32(Wd-M0599)-5.1B-6 , 63Mm Pvc Thered Adeptor P210(Wd-M0114)-1.5-10 , 90X63 Pvc Reducer P08(Wd-M0079)-1.4-3 , 50Mm Gm Gate Value P-33(Wd-M0618)-5.2-1 , Supply And Delivery Of Ms Kiosk Of Size 0.75Mx0.45X0.75M Made Up Of Ms Angle Of Size 50Mmx50mmx4mm Alround Covered With 16 Gauge Ms Sheet And Kiosk Door Made Up Of Ms Plates Of Size 25Mmx3mm Including Cutting,Welding,Grinding,Locking Arrangements And Labour Charges Etc,..Completed. P91(Wd-M1471)-18.0-1 , Laying Of Lt Cable Weir 4 Sq.Mm P-125(Wd-M1984)-12.2-1 , Supply,Delivery, Laying And Jointing Of 90Mm Od Pvc 4Ksc Pipe Inlcuding Earth Work Excavation In All Strata Soil, Refilling And Hydraulic Testing, Adopting Standard Specification And As Directed By Twad Board Officer. , 90Mm Pvc Bend P10-Sor -2024-2025-Wd-M0107 , 90Mm Pvc Tee P10-Sor -2024-2025-Wd-M0113 , 90Mm Pvc Elbow P10-Sor -2024-2025-Wd-M0112 , 90Mm Pvc Threaded P10-Sor -2024-2025-Wd-M0114 , 90Mm Pvc End Cap P10-Sor -2024-2025-Wd-M0115 , 80Mm Gm Gate Valve P33-Sor -2024-2025-Wd-M0618 , Provision For Name Board Charges , Gst Amount For Providing Service To Government Contract Works For The Above Construction & Maintenance Works. { Gst Amount Is The Total Gst Amount For Overall Quoted Amount (Both Construction And Maintenance) Above This Row In Column Bb For All Works In This Package} (Refer Clause 13.2 & 13.3 Of Section 2 Of Instruction To Bidders (Itb) Of Sbd)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
38.
Public Administrative Department #10723513 Price Bid
Tender for Labour For Boring Through Any Type Of Soil For Sinking Tube Well Of Required Dia, With Top Enlargement By Rig Boring System (Either By Reserve Circulation Or By Direct Rotary Method) Including Hire Charges And Labour For Rig Machine, Tools And Plants, Staging, Force Pumping Set And Making Arrangement For Water Required For Boring Etc. Complete And Lowering Of Pipes, Strainers, Blind Pipes Etc. Complete. First. 50 Mtr , Labour For Boring Through Any Type Of Soil For Sinking Tube Well Of Required Dia. With Top Enlargement By Rig Boring System (Either By Reserve Circulation Or By Direct Rotary Method) Including Hire Charges And Labour For Rig Machine, Tools And Plants, Staging, Force Pumping Set And Making Arrangement For Water Required For Boring Etc. Complete And Lowering Of Pipes, Strainers, Blind Pipes Etc. Complete. Next 50 Mtr , Supplying, Fibre Glass Reinforced Epoxy Resin Slotted Of 1 Mm Slot Width In 6.1M Length Of Approved Make And As Per Direction Of The Engineer-In Chargesupplying, Fibre Glass Reinforced Epoxy Resin Slotted Of 1 Mm Slot Width In 6.1M Length Of Approved Make And As Per Direction Of The Engineer - In Charge , Sypply Of E.R.W.M.S.(Electrical Resistant Welded M.S.) Black Pipe Of Of Tata Make (Heavy Quality) As Per Standard Specification, 5 Mm Thick. , Labour For Jointing And Lowering G.I. Or E.R.W. M.S. Pipes Including Strainer Within The Tube Well Bore Vertically With Necessary Sockets, Special Fittings And Welding As Required Including Cost Of All Jointing Materials, Hire Charges Of Tools And Plants, Cutting Pipes To Required Sizes, Making Threads, Welding Pieces Together Etc, As Necessary As Per Direction Of The Engineer-In-Charge , Washing And Developing Tube Well With Air Compressor Pump And Engine For 8 (Eight) Hours Continuous Pumping Per Day With Necessary Arrangements For Testing The Yield In Gallons Per Hour With V Notch. Including Hire And Labour Charges For All Tools And Plants And Scaffolding As Required. , Labour For Ma
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
39.
Public Administrative Department #10611317 Price Bid
Cooler Supply Work In Various Authorized Sections Of Municipal Corporation Bikaner . , Supply , Installation , Testing And Commissioning Of Desert Cooler Of Reputated Brand At Corporation Offices . , Supply Of Desert Cooler Stand With Wheels . Stand Shall Be Coated With 2 Coats Enamal Paint . , Desert Cooler Specifications :- Cooler Shall Have Electronic Regulator Confirming To Is:11037 / 84 . A Rotary Type 4 / 5 Positions Switch Having Marking Off , Low , Mid , High . Separate Switches Shall Be Provided For Pump And Fan . Tank Capacity 80-100 Litre , Cooling Area At Least 200 Sq Ft . , Air Throw Length 30 Ft . Motor Specifications :- Motor Pump Shall Be Of Branded Make And Isi Marked In Compliance Of Is:996 / 79 . Motor Pump Shall Have Copper Windings , Double Ball Bearing . Speed 1200-1400 Rpm . Operating Voltage 150-270V . Efficiency Atleast 73% , Class E Insulation , A . C Single Phase 410W , 2 Amp , 50Hz . Fan Size 450Mm , Direction Anti Clock Wise , Propeller Type A . C . Ventilating Fan , Is :2312 / 1967 . Pump Specification :- Water Pump Shall Be Provided With Proper Clamping Arrangement . Pump Shall Confirm To Is:11951 / 82 . Body Material Shall Be Made Of Plastic . Flow Rate Atleast 50Lpm , Inbuilt Thermal Overload Protection Power Rating 18 Watt , Head Atleast 1 . 6Mtr Outlet Size 12 . 7 Mm Body Specifications :- Filter Panel , Front Grill And Top Of The Cooler Shall Be Made Of 0 . 80Mm Gs Sheet . Tank And Rest Of The Body Shall Be Made Of 1 . 2Mm Thick Gs Sheet Confirming To 375 Grade And Is:277 / 85 . All Internal Surfaces Including Inside Of The Tank , And Blades , Motor Body , Pump , Pump Body And Frame Shall Be Painted With Water Resistant Paint Confirming To Is:9862 / 81 . Cooler Shall Be Fitted With 4 Inches Width Honey Pad For Water Circulation . Internal Sides Of Cooler Shallbe Painted Entirely With Rubber Paint For Leak Proof And Corrosion Free Operation . The Wood Wool Shall Be Placed In The Wiremash , The Filter Pads Shall Be Spread Uniformly Over The Panel And Fixed With Clamps To Avoid Sagging Of The Pads . The Wire Mash Shall Be Galvanised And Coated With Water Resistant Paint . Contractor Shall Provide Warranty For Cooler Body , Motor , Fan , Submersible Pump For Atleast 1 Year .
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
41.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
42.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
43.
Health and Family Welfare #10551406 Price Bid
Tender For Remaining Electrical Work Phc Building At Sadri District Jodhpur - 1 (Integrated Elect. BSR 2021) Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18SWGHotDippedGalvanized ModularBox withearth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pinceilingrose/lampHolder/3pinconnector,screwsetc, making connections,all as per pre approved by Engineer in charge, testingetc.completeasrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheets & Electrical/ Wiring accessories referChapterE-04,E-05&E -07 .For additional technicalparametersofproducts/ work, refer Annexure A attached with this BSR. 2 Medium point (up to 6 mtr.) 3 Long point(up to 10 mtr..) 4 WiringoftwincontrollightpointasperPWDspecificationfor electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor 1.1kVgrade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2Nos6AtwowayModularswitch,3pinceilingrose/lamp holder/ 3pinconnector,Modularfaceplatewith gridplate, screws etc,all as per pre approved by Engineer in charge,making connections,testingetc. completeasrequired. Forspecification ofcopper Conductor, PhenolicLaminated sheets&Electrical/ Wiringaccessories referChapterE-04,E-05&E-07. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Medium point (up to 6 mtr.) 5 Long point(up to 10 mtr..) 6 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification forelectricalWorkswithISI marked1.5 sq.mmnominalsizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit&itsallaccessories(J.B.,Bendsetc.),roundtiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, makingconnections,testingetc.completeasrequired. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work refer Annexure A attached with this BSR . On board 7 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 x 1.5 sq.mm 8 3x 1.5 sq.mm 9 2 x 2.5 sq. mm. + 1x1.5sqmm 10 1 x 4.0 sq.mm 11 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 12 1 x 6.0 sq.mm 13 4 x 6.0 sq.mm 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 16.0 sq.mm 17 S&Ffollowingsizes(dia.)ofISImarkedMMS(IS:9537P-III) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptancetests reports byanyNABLaccreditedlabfortheconduitshallbesubmitted before execution & All as per pre approved by Engineer in charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit 18 25 mm 19 32 mm 20 Supplying andLaying ISImarkedP.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type Aor C,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6.0 Sq.mm 3 core flat / Round 21 Providing & Fixing of phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 75 mm dia 22 P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single pole MCB6 A to 32 A rating 24 Double pole MCB 40 A rating 25 Four pole MCB 50-63 A rating 26 Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . IP-43 Double door (single phase) 27 16 Way (16 O/G +2 I/C) 28 IP-43 Double door (Three phase) 6 Way ( 18 O/G + 8 I/C ) 29 Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA ) powed coated enclosure as per PWD specification for electrical Works conforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 A Double Pole(single phase Three pin ) 30 Providing & Fixing of recessed/surface mounting heavy duty sheet steel not less then 1.2 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . For TPN 6 way DB 31 Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Providing & Fixing of ISI marked (IS:2268-1994) gong bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 33 Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 5 step fan regulator 100 watt 2 Module 34 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 36 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 37 Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type 38 Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field- programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type Confirming to IEC 62053-21 Below 500 A 39 Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Red/yellow/Green colour 40 Blue / white Colour 41 Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA 42 Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 43 Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV 44 SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 45 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 46 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Open execution type 160 A 47 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 %& as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Armoured Cable 6.0 Sq. mm 2 core 48 10.0 Sq. mm 2 core 49 35.0 Sq. mm 4 core 50 Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 110 / 95 mm 51 SITC of chemical Gel earthing system of Dual Pipe Technology made of with B Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second. (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts. (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell GI pipe 2000 mm long, 80 / 50 mm, Terminal 50mm x 6 mm GI Strip 52 Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 25mm x 3mm Alum. Strip 53 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 100 mm dia. 54 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start,aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to al lthe performance requirements laid down in IS 374:2019 inluding all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 55 Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR300 mm sweep(900/1400 RPM) 56 Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size 57 P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Up to 380 mm size 58 Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 15 Ltr. 59 25 Ltr. 60 SITC of ISO Certified company made MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel (SS grade:304) storage tank with electrical back up with Portable Residual Current Device ( PRCD ) facility form OEM , CRCA Powder coated /MS stand for Collector & Tank etc. as required. of following capacity complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 100 litre/ day 61 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 4 LED Tube shape fixture 1 X 18/20 W 62 Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. Surface Mounting LED Downlight 18/20W 63 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attached with this BSR. Suspended Mounting/Surface Mounting 36W LED light fixture 2x2 with acrylic / prismatic front cover. 64 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stabilization report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumenmaintained,colorRendering Index>70 andCCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . LED Street Light fixture 70 Watt 65 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 66 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, separated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 67 Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessary connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, Un-sheilded Information Outlet 68 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single Aperture 69 Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 U wall mounted Enclosure 70 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 12 Ports 71 Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play easy setup with no configuration or no software needed, following Port fast ethernet - 8 10/100/1000 MBPS gigabit auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 24 Port 72 Supply Installationtesting&CommissioningofISOcertified manufacturer made Monoblock motor pump set ISI marked (IS:9079- 2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2- 1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, . Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 73 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 74 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord 1 Mtr 75 2 Mtr 76 Supply , Installation, Testing and Commissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accelerated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Non Invertor Type 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5 ) 77 Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 mm dia 78 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accelerated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kVA 79 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accommodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length 80 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 81 Supply , Installation, Testing and Commissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray, minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 82 Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kg 83 Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35mm x 35mm x 5mm 84 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 A one way switch 85 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR6 A3/5 pin shuttered socket
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
44.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
45.
Educational and Research Institute #10551346 Price Bid
Tender For Remaining Misc Work At Gargi Hostel Mlsu - 1 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 2 Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) 3 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 4 Random rubble dry stone kharanja under floor. 5 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished 20 mm thick. 6 Finishing with neat cement (punning). 7 Providing and Laying 80 mm thick cement concrete blocks of M-40 Grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concretemix. Manufactured with steel moulds(Milled and manufactured in CSI diamond or CSI Nitro process foraccuracy) on steel base plate of min 16 mm thick; Having Vibration and pressing action both together with the helpofmultiple synchronised vibrators. Power of hydraulic station should be minimum 50KW for compaction and cured incontrolled chambers having humidity control and automated air circulation system) spreading 25mm thick sand underneath and filling joints with sand on existing W.B.M.base, as per IS15658:2006 and all materials shall conform to MoRTH Specification Clause 602. 8 S/F in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. 9 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to bestrutted with 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. 10 Extra for using galvanized barbed wire instead of black barbed wire 11 Carriageof earth including loading, unloading etc. lead upto 5.0 Km.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
46.
Health and Family Welfare #10545347 Price Bid
Tender For Construction Of Janta Clinic At Part Of Mact Court Building District Court Campus Pali - Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 2 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 3 20mm thick. 4 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing 5 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 6 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 7 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 8 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 9 Cement Mortar 1:6 ( 1-Cement : 6-Sand). 10 Supplying and fixing Soorsagar Bhura or Equivalent ashlar sills, lintels and dassa, bearing, bed & top surface made perfenctly even, jambs, skirting steps etc. rough dressed: 11 Upto 15 cm. thick 12 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 13 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 14 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 15 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 16 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : 17 Windows fixed 18 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 19 Size 300mm x 450mm 20 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. 21 size 600 mm X 600 mm 22 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 23 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 24 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 25 Commercial Veneer both side 26 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 27 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 28 Jalore (P-white / S-white/ Rosy Pink colour) 29 Above 3601 Cm2 Slabs 30 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 31 Granite/Kota Stone Work 32 Full Edge moulding 33 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) 34 Light shade using shade cement. 35 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 36 Grade 304 37 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 38 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: 39 Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 40 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 41 Two or more coats on new work 42 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 43 Deep groove pointing 44 Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 45 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 46 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 47 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 48 New Plastered Surface (three or more coats) 49 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). 50 For fixed portion 51 Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 52 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 53 Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 54 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. 55 Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 56 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) 57 With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 58 (Part B : Sanitary Works) P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 59 P & F water closet Seat Covers with brass hinges complete : 60 -do- White. 61 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. 62 Mini stall size 455x385x350mm. 63 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: 64 PVC with PVCbend as per IS : 7231 . 65 P & F C.P. brass Urinal Spreader for stall urinal of approved make. 66 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : 67 Size 510 mm x 400 mm 68 P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge 69 Size 500x400mm 70 P & F Towel Rail or Ring of approved quality/make: 71 C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty). 72 P & F Grating of approved quality/make: 73 Stainless Steel Sheet size 125mm dia. 74 P & F Soap Dish or Tray of approved quality/make 75 C.P. brass 76 P & F Extension Pipe for bib cocks of approved quality/make. 77 C.P. brass of Heavy & Superior quality 50x15mm 78 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 79 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: 80 C.P. Brass bib cock,15mm nominal bore. 81 (-do-) Long body, 15mm nominal bore weight not less than 690 gm 82 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: 83 C.P. Brass 15mm nominal bore. 84 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : 85 Brass wt.Not less than 400 gm, 20mm. 86 P & F 15 mm. Dia Connection Pipe of approved quality/make : 87 (-do-) 600mm. 88 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 89 (-do-) 20mm nominal bore. 90 (-do-) 25mm nominal bore. 91 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 92 500 (-do-) 93 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 94 Hoisting Charges for each floor : 95 For items 2.26.1 to 2.26.4 96 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 97 20mm nominal size 98 25 mm nominal size 99 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. 100 Depth up to 0.5 M 101 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: 102 Size 240 Cm. dia outside & 240 Cm. depth. 103 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 104 75 mm dia 105 110 mm dia 106 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 107 Bend 87.5 Dg. 108 75mm dia 109 110mm dia 110 Bend 45 Dg. 111 110mm dia 112 Door Bend 87.5 Dg. 113 110mm dia 114 Pipe Clip 115 110mm dia 116 W.C. Connector (Bend) with ring 117 110mm dia 118 Single Tee 119 110mm dia 120 Nahni Trap with Jali 4” 121 110mm dia 122 Vent Cowel 123 110mm dia 124 (PART C : ELECTRICAL WORKS) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 125 Short point (up to 3 mtr.) 126 Medium point (up to 6 mtr.) 127 Long point(up to 10 mtr.) 128 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 129 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 130 20 mm 131 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 132 1 x 1.5 sq.mm 133 1 x 2.5 sq.mm 134 1 x 4.0 sq.mm 135 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 137 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 139 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 141 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Surface Mounting (with extruded alumn. Housing ) 143 Minimumlumen output 650 lm 144 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 LED Street Light fixture with Minimum lumen output 5600 lm 146 LED Street Light fixture with Minimum lumen output 7500 lm 147 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 148 25 mm Dia. 149 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 600mm , Min. Lumens output 1800 lmLED Tube rod with Polycarbonate Housing 151 P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Openingof following size and made out from 24 SWG GI sheet as per instructions of Engineer in chargeincluding fixing with suitable fasteners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 152 Suitable for 380 mm sweep Exhaust Fan 153 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 154 1.5 TR ISEER not less then 3.8 155 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 156 20 mm 157 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 158 4 kVA 159 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 160 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 161 10 Ltr. 162 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 163 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
48.
Public Administrative Department #10510605 Price Bid
Construction Of Community Hall At Ward No 15 Kuppan Kuzhi At Kattumannarkoil Town Panchayat Construction Of Community Hall At Ward No 15 Kuppan Kuzhi , Earth Work Excavation In All Classes Of Soils Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Murram, Ordinary Earth, Earth Mix With 50% Fair Sized Boulders Etc., With Initial Lead And Lifts Including Laying, Spreading, Leveling, Sectioning Breaking Clods Etc., Includingall Incidental Charges Etc., Complete As Per Standard Specification . For Foundationsss 20B , Supply Delivery And Filling Of M. Sand In Layer Of Not More Than 15 Cm Thick Including Watering With All Layers And Consolidation Complying With Standard Specification Including Cost And Conveyence Of Sand To Site And All Labour Charges And All Other Incidential Charges Etc,. Complete As Per Standard Specification , Cement Concrete Of Mix 1:4:8 (One Cement Four Sand Eight Aggregates) Using 40Mm Gauge Hard Broken Including Cost Conveyance Of All Materials To Site Including Labour Charges, Transporting And Placing In Position Including Shoring, Strutting Forming Protective Bunds, Cofferdams Bailing Out Of Water Labour For Mixing Compacting, Finishing And Curing, Working At Depths, Tools And Plants And Incidental Charges Such As Sheeting, Shoring And Bracing And Their Subsequent Removal Etc., Complete As Per Standard Specification. , Rcc1:1½:3 (One Cement One Point Five Sand And Three Aggregates) Mix Using 20Mm Gauge Hard Granite Broken Stone Jellyin All Rcc Works Connected To The Work Excludingshuttering , Centering And Cost Of Reinforcement Grills Butincludingcuring ,Finishingetc Complete With Standard Specification And As Directed By Engineer Incharge. , Without Strutting , With Strutting , Supplyingandfabrication Of Steel And Placing In Position Ms / Ribbed Tor Steel Grills For Rcc Works As Per Design Given Including Cost Of Steel And Gi Binding Wire In Floors Etc,. Complete Complying With Standard Specification In Force And As Directed By Department Officials.- , Brick Work In Cement Mortar In 1:5 ( One Cement And Five Sand ) Using Best Quality Of Country Bricks Of Size 8¾X 4 ¼ X 2 ¾ Including All Cost Of Materials And Labour Charges Includingcuring Charges Etc., Complete As Per Standard Specificationand As Directed By Department Officials. , Special Ceiling Plastering With Cement Mortor 1:3(One Cement And Three Sand) Mix 10Mm Thick Including Cost Of All Materials And All Labour Charges Etc., Complete Complying With Standard Specifications. , Plastering The Surface Of Walls With Cement Mortor 1:5(One Cement And Five Sand) 12 Mm Thick In All Floors Including Cost Of All Materials And All Labour Chargesetc Etc., Complete Complying With Standard Specifications. , Paving The Flooring With Vitrified Tiles Of Size 600Mm X 600Mm X 8Mm Of Approved Colour And Qualitylaid In Cement Mortar 1:3 (One Cement And Three Sand ) 20Mm Thick In All Floors And The Top Pointed With The Colour Cement Etc., Complete. , Dadoing Walls With The Following Types Tiles Of Suitable Size Of Approved Quality And Colour Set In Cement Mortar 1:2 (One Cement ,Two Sand); 10Mm And Pointing With Colour Cement Neatly Etc., Complete In All Floors. , Teak Wood Framesfor Doors,Windows &Ventilators Supplying And Fixing T.W Frames For Doors,Windows, Ventilatorsand Other Similar Joinery Works With The Following Sizesand Sectionsincluding Labour Charges For Wrought And Put Up Inposition And Also Labour For Fixing Hold Fast In Frames And Masonry Etc Complete In All Floors Door Frame , Teak Wood Framesfor Doors,Windows &Ventilators Supplying And Fixing T.W Frames For Doors,Windows, Ventilatorsand Other Similar Joinery Works With The Following Sizesand Sectionsincluding Labour Charges For Wrought And Put Up Inposition And Also Labour For Fixing Hold Fast In Frames And Masonry Etc Complete In All Floors Door Shutters , Supplying, Fabricating And Fixing In Position Anodised Aluminium Natural Colour Matt Finish Sliding Windows/Openable Windows In All Floors With Gutter Arrangement To Drain The Water Made With Extruded Aluminium Section Of The Sizes Given Below With Necessary Acessories Such As Rubber Beading.Best Quality Runner, Lock, Handle Supplying And Fixing 4Mm Thick Plain Glass Including Cost Of All Materials, Labour Power Consumption Required For Fabrication, Drilling Holes In Rcc Column/ Floor Slab/Masonry Wall Wherever Necessary With Power Drills And Made Same To Original Condition After Fixing Etc.,Complete .The Aluminium Sections Are To Be Anodized With Matt Finish Under Electrically Controlled Condition In Accoradance With Isi 1868/1962,For An Average Anodic Film Thickness Of Not Less Than 15 Microns All Aluminium Sections And Furniture Fittingsshould Be Got Approved By The Engineer-In-Charge Before Use On Works. , Supplying And Fabrication And Fixing In Position Of Anodisednatural Colour Matt Fininsh Sliding Window In Twotrack In All Floors With Following Sizes. All The Two Shutters With Slinging Entering And Made With Upvc (Ultra Polyvinyl Chloride )Section For Outer Frames As Shown Below With Necessary Accessories Such Rubber Beading.Clips,Handle And Fixing 5 Mm Thick Clear Sheet Glass Including All Required For Fabrication Etc., Complete. Necessary Dismantling Making Holes In Rcc Columns, Beams, Mansory Wherever Necessary With Power Drill To The Extent Required And Made Good To The Original Conditions After Fixing As Directed By The Depart Ofmental Officers.(All Materials Should Be Got Approved By The Executive Engineer Before Fixing In Position). , Supplying And Fixing In Positon Of R.C.C. Jally Of 5 Cm Thick In Cc1:2:4 Using 20 Mm Machine Crushed Jelly Including Moulding, Finishing, Curing And Fixing In Posiion Etc., Complete. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris, Putty, Wherever Required Etc., Complete Complying With Standard Specification. , Supplying And Painting New Wood Work With Two Coats Of Synthetic Enamel Paint Of Approved Quality And Colour Over One Coat Of White Primer In All Floors The Rate Is To Include Cost Of All Materials,Brushes, Scaffolding Charges Etc., Complete , Supply And Run Of 2 Of 1.5 Sqmm (22/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100V Grade In Rigid Pipe Concealed In Wall And Ceiling With Continuous Earth Wire Connection Of 14Swg Tc Wire And Making Good Of The Concealed Portion With Suitable Colour Sd 53 , Wiring With 2X1.5 Sqmm (22/0.3) Pvc Insulated Sc.Unsheathed Cu. Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories And With Tw Switch Box And 5A F.T. Switch With Paintingof Suitable Colourfor Open Pvc Light Point / Fan Point (For Electronic Regulator) (5 Points Per Coil)Sd 22 , Wiring With 2X1.5Sqmm (22/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories With 150 Mm X 100 Mm X 113Mm Tw Switch Box In Flush With Wall With 3 Mm Thick Hylem Sheet Cover For 5 A 3 Pin Non Inter Locking Cs Plug With Painting Of Suitable Colour With Continuous Earth Wire Connection Of 14 Swg Tc Wire For Open Pvc Plug Point.Sd 35 , Supply And Fixing Of Single Box Type 440 W Flu Fitting Complete With Copper Choke And Condensor With Tw Round Blocks On Wall Or Ceiling With Flu Tube With Pvc Unsheathed Copper Leads From Terminals To The Fitting. Sd 83 , Supply And Fixing Of Wt Bulk Head Fitting With Guard (Philips / Bajaj / Crompton / K. Lite) Suitable For Incandescent Lamp With 60 W Bulb. Sd 80 , Supply And Fixing Of 1200 Mm (48) Sweep Ac Ceiling Fan Complete With Stepped Electronic 300W Regulator, With 1 Metre Down Rod With Fan Clamp With Side Plates And Cross Arm Of Size 450 Mm (18)Sd 102 , Supply And Fixing Of 32 Amps Dpic Switch Of 500 V With Metal Clad With Fuse And Neutral (Side Handle) On Suitable Tw Board , With Earth Connection Only Sd 138 , Earthing As Per P.W.D Standard With An Earth Electrode Of 2 Mtr. Class B Gi Pipe Of Dia Not Less Than 32Mm Complete With Necessary Masonry Work Sd 228 , Supply And Fixing Of Tneb Meter Board Suitable For 32A Single Phase Service Connection With 32A Fuse Unit (500V) 32A Neutral Link And Earth Link (1 X 1/8 Copper Flat) On Tw Plank Of Size 375Mm X 300Mm X 19Mm With Supporting Tw Reepers Of 1 Thick An Either Side With Painting With Suitable Bolt And Nuts For Fixing The Tw Plank On Wall With Earth Connection And Inter Connection With 7/20 Pvc Insulated Copper Wire From Eb Meter To Fuse Unit. Sd 121 , Supplyind And Fixing Following Thickness Of Polished Cuddapah Slab For Cupboard Etc, Complete In All Floors. , Supplying And Fixing Pvc Rain Water Down Fall Pipes Of 4Kgf/Cm2 Variety Of The Following Sizes Excluding Cost Of Pvc Specials But Including Charges For Fixing Them In Position With Nessary Shoes, Bends, Clamps, Twplugs, Screws, Nails Etc., Complete. , Supplying And Fixing In Position Best Quality Approved Make White Glazed Earthenware Wash Hand Basin Of Size 550 X 400 Mm With A Pair Of Cast Iron Brackets, Including Cost Of 15Mm Dia Brass Chromium Plated Piller Tap, 32 Mm Dia C.P. Waste Coupling, 32 Mm Dia P.V.C. Waste Pipe With Rubber Plug And Chain, 15Mm Diametre G.M.Wheel Valve, 15Mm Dia Brass Nipple, 15Mm Dia Nylon Connections Etc., Including Fixing The Wash Hand Basin In The Wall In Position With A Pair Of C.I. Brackets With Teak Wood Plugs And Screws And Giving Necessary Water Supply Connection And Paintiung The Brackets With Two Coats Of Paint Over A Primimg Coat Of Anticorrosive Paint Including Testing For Leackage Etc., Complete Complying With Standard Specifications (The Wash Hand Basin And Specials Should Be Got Approved By The Executive Engineer Before Use On Works) , Supplying And Fixing In Position White Glazed Indian Water Closet Of Size 580 X 440Mm Of Orissa Type Of Approved Quality With P Or S Trap With Sand Cushion And Forming Flooring Alround The Closet Using 40Mm Broken Brick Jellylime Concrete 1:2:5 ; 100Mm Thick And Finishing The Top Torequired Slope And Including Giving Necessary Connection To Cast Iron Soil Pipes By Dismandling Masonry / Rcc Works And Making Good The Disturbed Portion To Original Condition Without Leakage Etc., Complete Complying With Standard Specifications And As Directed By The Departmentalofficers. (The Water Closet Should Be Got Approved By The Executive Engineer Before Use On Works.) , Drilling Of Borewells Anywhere In Tamilnadu Including Transportation From One Place To Another With In Tamilnadu In Alluvial Soil Sedimentary Strata Of Clay And Sand Stone Shale Pebbles Boulders Etc. By First Taking A Pilot Bore Of 140Mm Dia And Then Enlarging To 150Mm Dia Bore By Direct Or Reverse Rotary Mud Circulation Method Using Rotary Rigs Fuel, Labour And Drilling Benonite And Water Required For Drilling At Site.Site Will Be Shown By The Departmental Officers Including Construction Of Mud Pit..Upto 60M Depth Ending Below Ground Levelupto 60 Mt. Depth Ending Below Ground Level , Reaming 200/350Mm Dia Pilot Bore To 300Mm Dia Bore As Directed By The Departmental Officers. Upto 60 Mt. Depth Ending Below Ground Level , Supply Of The Following Casing Pipes Of Isi Approved Quality With Wall Thickness Not Less Than 7.5Mm To 8.5Mm With Pvc Couplers And Cement Paste Etc. Complete And Including Packing The Annular Space With Pebbles Quality And Size Of Pebbles And The Pvc Pipe Should Be Approved By The Departmental Officer. 150Mm Diaod Pvc Plain Casing Pipe (Cs) , 150Mm Diaod Pvc Slot Casing Pipe (Rs) , 150Mm Diaod Pvc End Cap , Labour Charges For Inserting150 Mm Dia Od Pvc Casing Pipes Assembly. (With Slots And Without Slots) In The Drilled Hole Including Jointing The Pipes With Pvc Couplers With Cement Paste Including Supplying And Packing Of Pebbles In Anular Spaces As Approved By The Asst.Exe.Engineer. , Charges For Developing The Borewell With Air Compressor Of 600Cfm. Capacity (Minimum 8 Hours )Including Transportation Labour And Fuel Charges For Compressor As Directed By The Departmental Officers And Conducting Yield Test By V Notch Methods. , Supply And Delivery Of 1Hp Single Phase Submersible Pumpset Of Duty Condition 20 Lpm X 40 M As Per Is 8034 Without Panel Board Etc Complete As Per Standard Specification. , Supply Of Single Phase Pannel Board Suitable For 1Hp With Two Level Guard And Auto Start Etc Complete As Per Standard Specification. , Supplying And Delivery Of 2.5Sq.Mm Of Pvc Insulated And Sheathed 3 Core Flat Type Copper Cable Confirming To Is694/ 1990Etc Complete As Per Standard Specification. , Labour Charges For The Errection Of 1Hp Submersible Pumpset In The Borewell Including Fixing And Jointing Submersible Cable With Proper Clamps Upto The Starter To Required Depth And Also Fixing Of Riser Pipes To The Required Depth Walls Errection Clamps Pressure Gauges Up To The Exterior Wall Of Pumping Room And Errection Of Panel Board Consisting Of Dpicnswitches Starter Volt Meter Ammeter, Three Pilot ( Indicating ) Lamps Capacitor Single Phasing Preventer Water Level Guard And Laying And Jointing The Cable S And Twin Earthing As Per Ie Rules Etc Complete And Testing To The Pumpset And Trial Run For 10 Days. , Supply And Delivery And Fixing Of Hdpe Tank 1000 Litres Capacity As Per Is 12701/ 1996 Including Loading, Unloading, Transportation And Labour Charges For Fixing Of The Gi Pipes And Specials For Pipe Connection Works Including Cutting, Threading And Fixing Charges As Directed By Departmetal Officers. , Service Pipestandard With An Earth Electrode Of 2 Mtr. Class B Gi Pipe Of Dia Not Less Than 32Mm Complete With Necessary Masonry Work , Supply And Run Of 2 Of 1.5 Sqmm (22/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100V Grade In Rigid Pipe Concealed In Wall And Ceiling With Continuous Earth Wire Connection Of 14Swg Tc Wire And Making Good Of The Concealed Portion With Suitable Colour Sd 43 , Supply And Delivery Of Pvc / Gi Pipes And Its Specials For Water Supply Arrengments, Including Cost And Conveyance Of All Materials And All Labour Charges Etc Complete As Per Isi Specification. 32Mm Gi Pipe , 32 Mm Upvc Pipe , 32Mm Gi Coupling , 32 Mm Union , 32Mm Gi Elbow , 32Mm Gate Valve , 50 Mm Ms Clampset , 50Mm Flange Set , 20 Mm Gi Pipe , 25 Mm Pvc Pipe , 20 Mm Gi Bend , 20Mm Gi Pipe Nipple , Bore Cover , Tap , From 12.30M Ht., To 13.30M Ht., , From 13.30M Ht., To 14.30M Ht., , From 14.30M Ht., To 15.30M Ht., , From 15.3 M To 16.3M Ht , Upto 0-3.30 M , 3.30 To 4.30 M, , 4.30 M To 5.30 M , 5.30 M To 6.30 M , 6.30 M To 7.30 M , 7.30 M To 8.30 M , 8.30 M To 9.30 M , 15.30 M To 16.30 M
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
49.
Public Administrative Department #10499862 Price Bid
Tender For Repair Maintenance Of Central Laboratory. Sub Work :- Supply Installation And Commissioning Of Scientific / Civil Engineering Lab Equipments. -Providing, Supplying, Commissioning And Demonstration Of Gi Frame Test Sieves 18” Dia Size:Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 2 50 Mm 3 25 Mm 4 31.5 Mm 5 16.0 Mm 6 12.5 Mm 7 10.0 Mm 8 6.3 Mm 9 Lid & Pan 10 Providing, Supplying, Commissioning And Demonstration Of Brass Frame Test Sieves 200Mm Dia. Size: 90 Mic. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 11 Providing, Supplying, Commissioning And Demonstration Of Brass Frame Test Sieves 200Mm Dia. Size: 500 Mic Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 12 Providing, Supplying, Commissioning And Demonstration Of Shrinkage Bar Mould Single Gang Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 13 Providing, Supplying, Commissioning And Demonstration Of Le Chatelier Mould, ( Set Of 6Pc ) Standards:Is 269, 712, 5514, 1727 , 2645, 6932 ( Part Ix ) Bs 6463Specification: It Consists Of A Small Split Cylinder Forming A Mould. On Either Side Of The Split Cylinder. Two Parallel Indicating Arms With Pointed Ends Are Attached. Supplied Complete With Two Glass Plates And A Lead Weight. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 14 Providing, Supplying, Commissioning And Demonstration Of Le Chatelier Water Bath Double Walled Inner Chamber In Stainless Steel Outer Chamber In Mild Steel Temperature Range Ambient To 100°C Controlled By Capillary Thermostat. Accuracy ± 1°C Operated On 230V A.C. Single Phase. These Baths Are Suitable For Washing Marshall Specimen. Lid Is Made Up Of Stainless Steel With A Hole For Glass Thermometer To Penetrate. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 15 Providing, Supplying, Commissioning And Demonstration Of Vicat Needle Apparatus With Dashpot With Mtcspecification:The Apparatus Consists Of A Metallic Frame Bearing A Freely Movable And With A Cap At Top, One Vicat Mould And Glass Base Plate And One Set Of Needles One Each Initial Needle, Final Needle And Consistency Plunger. It Comes With A Dashpot Which Facilities Gentle Lowering Of The Needles. Accessories : Mild Steel Base Plate 5 Inches X 5 Inches. Fulcrum Mould , Brass , 80 Mm I.D. Base Dia X 70 Mm I.D. Top Dia , 40 Mm Height. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 16 Providing, Supplying, Commissioning And Demonstration Of Specific Gravity And Water Absorption Of Aggregates Model With Nablcalibration Certificate Standards: Is 2386 ( Part Iii ) & Bs 812Specification: The Buoyancy Balance System Consists Of A Rigid Support Frame, Incorporating A Water Tank Mounted On A Platform. A Mechanical Lifting Device Is Used To Raise The Water Tank Through The Frame Height Immersing The Specimen Suspended Below The Balance. The Balance Supplied May Also Be Used As A Standard Weighing Device, Thus Providing A Versatile And Comprehensive Weighing System In The Laboratoryspecification:The Outfit Comprises Of• Electronic Balance, Capacity 15 Kg. Least Count 0.5Gm, Provision Is Made In This Balance To Suspend Density Basket Under Material Pan. This Balance Is Mounted On An Angle Iron Frame Stand. 1 No• Density Basket. 1 No• Air Tight Container To Suspend Density Basket. 1 No• Gi Tray Of Area Not Less Than 650 Cm Sq. 1 No.• Absorbent Cloths 75Cm X 45Cm. 2 Nos. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 17 Providing, Supplying, Commissioning And Demonstration Oflos Angeles Abrasion Testing Machine With Nablcalibration Certificate Standards: Is 2386 ( Part Iv ) Astm C 131, Aashto T-96Specification:The Machine Consists Of A Hollow Cylinder Mounted Horizontally On A Study Frame On Ball Bearings. There Is An Opening Which Can Be Closed With A Dust Tight Cover To Facilitate Charging And Discharging The Drum With The Material Under Test. A Detachable Shelf Which Extends Throughout The Inside Length Of The Drum Which Catches The Abrasive Charge And Does Not Allow It To Fall On The Cover. The Drum Is Rotated By An Electric Motor Through A Heavy Reduction Gear At A Speed Of 30-33 R.P.M. A Revolution Counter Is Fitted To The Frame. A Tray Is Supplied For Collection Of The Material At The End Of The Test. Complete With Abrasive Charge Consisting Of A Set Of Twelve Hardened Steel Balls, Approximately 48Mm Dia. Suitable For Operation On 440 V, 3 Phase, 50 Cycles, A.C. Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 18 Providing, Supplying, Commissioning And Demonstration Of Electrical Oven Doublewall For Soil Inside Chamber In Ss Outside Mild Steel With Digital Temperaturecontroller Along Withblower With Circulation The Airambient Temperature With Two Tray 2500Csize: 18”X18”X18” With Nablcalibrationmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 19 Providing, Supplying, Commissioning And Demonstration Of Digital Double Door Oven Zi Model No : 9014225 Liter Cap. , Temp. Amb. To 250 Degree C Or Equivallent Specificationthis Range Of Ovens Is Designed For Drying Large Quantities Of Soil And Aggregate Samples And Maintains Temperature In Accordance With Most B.S. And Astm Requirements.The 225 Lts. Are Economy Models Constructed With Coated Mild Steel Exterior And Stainless Steel Coated Interior Chamber, Which Is Both Durable And Corrosion Resistant.These Units Meet The Requirements Of Bs 1377 And Are Ideal For On-Site Laboratories And General Soil And Aggregate Testing. Options And Accessories:• Dial Thermometer With Collar Fixing For Door• Heavy Duty Shelves ( On Request At An Extra Price ) • Color Of The Oven ( Only On Qty. Greater Than 3 Units ) Specifications:• The Larger Soil Drying Ovens Are Constructed With Mild Steel And Powder Coated Exterior And Stainless Steel Coated Chamber Which Is Both Durable And Corrosion Resistant.• All Sizes Of Oven Are Fitted With A ( Pid Controller ) Having A Microprocessor Digital Control As Standard.• All Units Comes With Mcb Tripping Device In Cases Of Any Short Circuit, Overloading Of Voltage And Low Voltage Cut Off. Wiring Of Heaters Can Be Connected / Dis-Connected Removing The Side Panels Of The Oven. 20 • Caster Wheels With Locking Arrangement Are Fitted Below The Oven For Easy Movability Of The Unit From One Place To Another. Door Locking Arrangement Is Very Easy Convenient With Lever To Lock Unlock With Half Turn Lever• A Safety Thermostat Is Fitted Inside The Oven For Safety Purpose. Incase Of The Failure Of The Pid Controller The Safety Thermostat Will Serve As The Temperature Controller.• A High / Low Switch Is Fitted On The Panel Of The Oven For Heaters. This Feature Allows Heaters To Burn All Together Or Half Of Them.• The Least Count Division For Viewing / Setting The Temperature Is 0.1º C Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 21 Providing, Supplying, Commissioning And Demonstration Of Standard Compaction Test ( Is ) Standards: Is 2720 ( Part-Vii ) Specification: Instrument Consists The Apparatus Consists One Each Of Compaction Mould Mild Steel, 100 Mm I.D. X 127.3Mm Height X 1000 Cc Volume, Complete With Collar And Base Plate.Compaction Rammer Is 2.6 Kgs In Weight X 310Mm Controlledfall Make Aimil / Lawrence & Mayo / Lynx / Enkay / Zeal International Enterprises. 22 Providing, Supplying, Commissioning And Demonstration Of Heavy Compaction Test ( Is ) Standards: Is 2720 ( Part-Viii Specification:Instrument Consists One Each Of Compaction Mould Mild Steel 150 Mm I.D. X 127.3Mm Height Volume 225°C. Complete With Collar And Base Plate. Compaction Rammer Is 4.89 Kgs. In Weight X 450 Mm Controlled Fall. Note : Instead Of Steel Moulds, Gunmetal Mould Are Also Available Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 23 Providing, Supplying, Commissioning And Demonstration Of Sand Pouring Cylinder – Is, Standards: Is 2720 ( Part Xxviii ) 1966Specification: This Apparatus Is Used For The In Place Determination Of The Dry Density Of Compact, Line And Medium Grained Soils And For Layers Not Exceeding 500Mm Thickness. The Complete Apparatus Consists One Each Of Small Sand Pouring Cylinder, 3 Litre Capacity Fitted With Conical Funnel And Shutter. Cylindercalibrating Container, Internal Dia 100Mm And 150Mm Height.Accessories:Metal Tray, 300Mm Square And 40Mm Deep With Hole Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 24 Providing, Supplying, Commissioning And Demonstration Of Liquid Limit Apparatus Hand Operated With Mtcspecification:Casagrande Method In Mechanical Form Is Known As Liquid Limit Method And Has Been In Use For Soil Mechanics For A Number Of Decades. The Liquid Limit Data Of Soils Is Useful To Correlate Mechanical Properties Of Soil, Such As Compressibility And Lower Shear Strength. Liquid Limit Is The Water Content At Which Soil Passes From Zero Strength To An Infinite Strength, Hence The True Value Of Liquid Limit Cannot Be Determined. For Determination Purpose Liquid Limit Is That Water Content At Which A Part Of Soil, Cut By A Groove Of Standard Dimensions, Will Flow Together For A Distance Of 1.25Cm Under An Impact Of 25 Blows In A Standard Liquid Limit Apparatus. The Soil At The Water Content Has Some Strength Which Is About0.17N / Cm. Sq. ( 17Gms / Sq.Cm. ) . At This Water Content Soil Just Passes From Liquid State To Plastic State.It Consists On A Brass Cup Held On An Adjustable Bracket.The Cup Can Be Adjusted For A Fall Of 1 Cm And Can Be Raised An Dropped On A Rubber Base Of Standard Hardness By Cam Action. Complete With One Casagrande Grooving Tool, One Astm Grooving Tool And A Height Gauge Block. A Counter To Register The Number Of Blows.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 25 Providing, Supplying, Commissioning And Demonstration Of Aggregate Impact Test Machine With Counter, Mould And Steel Rod 16 Mm Dia. 26 Providing, Supplying, Commissioning And Demonstration Of Plastic Limit Set Model Is 2720 ( Part-Vii ) Astmd-42, Bs 1377 Aashto T 90Moisture Contents At Which Soil Has Smallest Plasticity Is Called Limit. For Determination Purpose Plastic Limit Is Defined As The Water Content At Which A Soil Will Just Begin To Crumble When Rolled In To A Thread Of 3Mm Dia.Specification:The Complete Set Consists Of One Each :1. Glass Plate 20Cm X 15Cm Having Round Ends2. Brass Or Stainless Steel Rod 3Mm Dia X 150Mm Long3. Flexible Spatula 15 Cm4. Set Of 6 Moisture Containers5. Porcelain Basin 150Mm Dia6. Plastic Wash Bottle 500Ml Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 27 Providing, Supplying, Commissioning And Demonstration Of Digital California Bearing Ratio Test Apparatus ( Cbr ) Standards: Is 9669, Is: 2720 ( Part Xvi ) With Nablcalibration Certificate The Lab Test Is Designed For Performing Laboratory Evaluation Of The Cbr Value Of Highway Sub Bases And Sub Grade And For The Determination Of Strength Of Cohesive Materials Which Have Maximum Particle Sizes Less Than 19 Mm ( 3 / 4” ) . The Machine Is Designed To Be Mounted On A Suitable Bench And Comprises Of A Robust And Compact Two Column Frame With Adjustable Upper Cross Beam. The Frame Is 50 Kn Capacity. Three Test Speeds Are Provided 1.25 Mm / Min, 1.50 Mm / Min & 2.5 Mm / Min Tests. This Main Feature Allows The User To Perform Tests. Laboratory California Bearing Ratio Apparatus With Software & Pc Interface. Zi 3066A Three Speed Load Frame, 50Kn ( 5000 Kgf ) Capacityzi 3066B Mould 150Mm Id X 175Mm Highzi 3066C Perforated Base Plate For Zi3074- 2 Mouldzi 3066D Extension Collar, 150Mm Id X 50Mm Highzi 3066E Penetration Piston, 50Mm Face Diazi 3066F Adjustable Bracket, For Penetration Dial Gaugezi 3066G Circular Metal Spacer Disc. With Detachable Handle 148 Mm Dia X 47.7 Mm High Time.Zi 3066H Annular Metal Weight, 2.5Kg, 147Mm Dia With 53 Mm Dia Central Hole 28 Zi 3066I Perforated Metal Weight 2.5 Kg. 147Mm Dia, With 53Mm Dia Softzi 3066J Perforated Plate, 148Mm Dia, With Adjustable Stem And Lock Nutzi 3066K Metal Tripod For Dial Gaugezi 3066L Cutting Collarzi 3066O S Type Load Cellcapacity 50 Knzi 3066P Lvdt, 25 Mm Travel, 0.01Mm Least Count Optional Extras:Salient Features:-• No Need Of Separate Observation On Dial Gauge And Proving Ring.• Facility To Readout Rate Of Loading In Mm / Minute.• Tare System To Nullify Initial Load The Digital Lcd Display Will Retain The Peak Value Until It Is Cleared.• Flow Value And Load On A Single Screen.• Flow Value With A Least Count Of 0.01 Mm With Accuracy Of 1%.• Load Value With A Least Count Of 0.1 Kg / 0.001 Kn With Accuracy Of 1%.• Back Light Facility To Observe The Readings Even In The Dark.• Two Line Readout Showing Load, Flow, And Speed.• Software Interface To Pc And Plot Live Graph. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises 29 Providing, Supplying, Commissioning And Demonstration Of Shrinkage Limit Set Standards:Is 2720 ( Part-V ) Astm D 427, Bs 1377, Aashto T 92.Specification:Shrinkage Limit Is The Maximum Water Content At Which A Reduction In Water Content Does Not Cause An Appreciable Reduction In Volume Of The Soil Mass. At Shrinkage Limit, On Further Reduction In Water, Air Enters In To The Voids Of Soils And Thus Keeps The Volume Constant.The Apparatus Can Be Used To Determine Shrinkage Limit And To Calculate Other Shrinkage Ratio, Shrinkage Index And Volumetric Shrinkageset Consists Of One Each:1.Porcelain Evaporating Dish2.Shrinkage Dish3.Glass Cup4.Perspex Plate With Three Metal Prongs5.Flexible Spatula 100Mm6.Glass Cylinder7.25Ml X 1Ml, Supplied Without Mercury8.Plastic Wash Bottle 500Mlmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 30 Providing, Supplying, Commissioning And Demonstration Of Enamel Tray Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 31 Enamel Tray 10 X12” 32 Enamel Tray 12” X18” 33 Enamel Tray 18” X24” 34 Providing, Supplying, Commissioning And Demonstration Of Triaxial Test Apparatus Electrical With 10 Kn Load Cell And 25 Mm X 0.01 Lvdt , 2 Channel Data Acquisition System And Software Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. ( Rates Included Sub Head A To D ) 35 Providing, Supplying, Commissioning And Demonstration Of Load Frame, Motorised, 3 Speeds With Dial Gauge Features: · Two Pillar Type ·Detachable Frame ·Enclosed Motor And Gear System · Jewel Lamps Indicating Direction Of Motion · Operational Ease · Useful For Triaxial And Cbr Tests The Load Frame Consists Of A Cabinet Which Houses The Gear System And Motor With Sturdy Angle Iron Frame. The Loading Is Done Through The Bottom Loading Platen, Which Is Carried On A Lead Screw, Which Advances Upwards. The Top Load Bracket, Which Slides Over Two Upright Pillars, Can Be Positioned At Any Desired Height And Locked. It Carries A Screw Adapter For Standard Proving Rings And Load Cells. The Loading Part Of The Unit Is Detachable From The Main Unit For Ease Of Transport And To Avoid Damage To The Tension Rods. Rates Of Strain: 6 Fixed Speeds 1.25, 1.50, 2.50 Mm / Min. Suitable For Operation On 230 V, 50 Hz, Single Phase, Ac Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 36 Providing, Supplying, Commissioning And Demonstration Of Lateral Pressure Assembly 10Kg / Cm² It Is Designed For Application Of Cell Pressure Upto 10Kg / Cm2 On A Triaxial Specimen In The Triaxial Cell. The Unit Is Mostly Used In Routine Tests Which Last For About 10 To 15 Minutes Wherein The Variations Of Cell Pressure Can Be Tolerated.Specification :The Apparatus Consists Of A Pressure Chamber Which Has A Flanged Top Cap Fitted With A 10 Kg / Cm2. Pressure Gauge And A Valve For Pumping In Air. Water Inlet And Drain Cock Are Fitted To The Chamber. The Foot Pump Supplied Easily Develops A Pressure Of 10 Kg / Cm2 Complete With Connecting Pressure Hose.Note: Also Available 20Kg / Cm2 Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 37 Providing, Supplying, Commissioning And Demonstration Of Triaxial Cell For 38 Mm Dia The Accessories & Foot Pump Specification:The Cell Is Useful For Testing 38Mm Dia X 76Mm High Soil Specimen. Transparent Perspex Chamber With Anvil And Loading Plunger, The Cell Is Easily Opened By Releasing Four Nuts Of The Tie Rods. It Is Leak Proof Up To 10Kg / Cm.Sq. Fluid Pressure. An Oil Plug Which Can Also Be Used As An Air Vent Is Provided For Introducing A Thin Layer Of Oil Over Water. This Provides Effective Sealing At The Plunger For Long Duration Tests. The Cell Is Fitted With Four Sleeve Packed Valves Of No Volume Change Type On The Base. These Valves Are Used For Cell Pressure, Pore Water Pressure, Drainage Or Back Pressure. The Loading Plunger Of The Cell Has Dial Gauge Rest.•Loading Pad Made Of Perspex For 38Mm Dia Specimens.•Pair Of Plain Discs Made Of Perspex 38Mm Dia 6Mm Thick.•Pair Of Porous Stones 38Mm Dia Specimen.•Split Sand Former For 38Mm Dia Specimen.•Sheath Stretcher For 38Mm Dia Specimen.•One Dozen Rubber Sheaths For 38Mm Dia Samples.•For Synthetic Rubber ‘O’ Rings For 38Mm Dia Specimen.•One Plastic Drainage Tube. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 38 Providing, Supplying, Commissioning And Demonstration Of Pore Pressure Apparatus 10 Kg / Cm² Specification: The Apparatus Consists Of A Panel For Wall Mounting On Which Are Fitted 1.0 To 10Kgmanom / Cm Sq X 0.1Kg Cm. Sq. A Pressure Gauge, Bourdon Tube Type 15 Cm Diameter: Glass U-Tube Manometer For Measuring Low Positive Pore Pressures Negative Pore Measures And Checking Zero Error Of Pressure Gauge. It Is Provided With A Mercury Trap ( Mercury Supplied At Extra Cost. ) Null Indicator Made Out Of Clear Transparent Perspex With Mercury Trap And Cursor To Indicate The Mercury Level. Burette: 50Ml Burette For Measuring The Volume Change In The Soil Specimen. Pressure Pump Fitted With Four Sleeve Packed Valves, Operated By Means Of A Hand Wheel On The End Of The Piston Rod Which Is Threaded Through The Pump Cap And Gives A Smooth, Fine Adjustment Of Pressure. Copper Coil And Water Reservoir Is Fitted On Board With Complete Stand Assembly. The Unit Is Tested Against Leaks Up To 10Kg / Cm Sq.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 39 Providing, Supplying, Commissioning And Demonstration Of Ring & Ball Apparatus ( Semi Automatic ) Model No. Zi 4003Ref. Standards - Is:1205, Astm D 36, E 28, Ip 198, Ip 58, Aashto T53, Bs:2000, En 1427 With Nablcalibration Certificate For Determining The Temperature At Which A Sample Of Bituminous Material Loaded By A 9.5 Mm Dia Steel Ball, Drops A Specified Distance When Heated Under Specified Conditions.Ring And Ball Apparatusthe New Design Of Ring And Ball Apparatus Is Compact User Friendly And Has Better Aesthetics. It Has Magnetic Stirrer With Heating Facility And Digital Display Of Temperature, The Heating Can Be Adjusted Through Knob.Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. Each Unit Is Supplied With A Bath Of Heat Resistant Glass And Thefollowing:Zi 4003-A Tapered Rings 2 Nos.Zi 4003-B Ball Centering Guide 2 Nos.Zi 4003-C Steel Balls Of 9.5 Mm Dia 2 Nos.Zi 4003-D Ring Holder 1 No.Zi 4003-E Electric Heater ( Hot Plate ) 1 Nos. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 40 Providing, Supplying, Commissioning And Demonstration Of Marshall Stability Test Apapratus Model No : Zi – 4022 Or Equivalentastm : D 1559 T-62 Bs 598-107 With Nablcalibration Certificate Marshall Apparatus Consists Of:• Robust Construction• 50Kn Capacity• Rate Of Travel 50.8Mm / Min• Safety Cut-Off Switchit Consists Of Body Housing, A Geared Screw Jack And Motor Drive Mechanism Suitable For Operation On 230 V, 50Hz, Single Phase, A.C. Supply.Zi 4022-A Marshall Load Frame 1 No.Zi 4022-B Breaking Head Stability Mould, 100Mm Mm With A Dial Gauge ( Having 25Mm Travel And 0.01Mmleast Count ) , For Flow Measurement 1 No.Zi 4022-C Compaction Mould, Steel Cylindrical 100Mm3 Nos.Zi 4022-D Base Plate 3 Nos.Zi 4022-E Extension Collar 3 Nos.Zi 4022-F Compaction Pedestal, 100Mmmanual Operation, Comprising A Steel Plate Capped On A Wooden Post. A Mould Clamp Is Fitted To The Top Of The Plate . 1 No.Zi 4022-G Compaction Hammer, 100Mmsatisfies Bs 598. The Hammer Has A 4535 G Sliding Weight With A Free Fall Of 457 Mm 2 Nos.Zi 4022-H Load Transfer Bar 1 No.Zi 4022-I Paper Discs, Non Absorbent, 11 Cm Diameter Pack Of 100 No. 1 Pkt.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 41 Providing, Supplying, Commissioning And Demonstration Of Marshall Mould Complete With Collar & Base Plate 100Mm Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 42 Providing, Supplying, Commissioning And Demonstration Of Centrifuge Extractor Motorised, Zi 4014 Or Equivalentstandards:Astm D2172 Aashto T-58, T-164Specification:Centrifuge Extractor, Electrical Operation, Capacity 1500G, With A Dimmer Stat For Speed Control From 2, 400 To 3, 600 Rpm. Suitable For Operation On 230 V, 50 Hz, Single Phase, A.C. Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 43 Providing, Supplying, Commissioning And Demonstration Of Ductility Testing Apparatusdigital Aimil Type Model No. Zi – 4025Or Equivalent With Nabl Calibration Certificatestandards:Is 1208-1058, Astm D 113, Ip32, 55, Aashto T 51Specification:Designed To Test Three Specimens Simultaneously. The Machine Consists Of A Carriage Moving Over A Lead Screw. An Electric Motor Driven Reduction Gear Unit Ensures Smooth Constant Speed And Continuous Operation. The Entire Assembly Is Mounted With A Stainless Steel Lined Water Bath Completely Encased In Metal Bound Hardwood. It Is Equipped With An Electric Pump Circulator And Heater. The Temperature Is Controlled Thermostatically. Two Rates Of Travel I.E. 50 Mm / Min And 10 Mm / Min Are Provided. Suitable For Operation On 230 V, 50 Hz, Single Phase, A.C. Supply. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 44 Providing, Supplying, Commissioning And Demonstration Of Standard Digital Penetrometer ( Made In Italy ) Used To Determine The Consistency Of A Bituminous Sample Under Fixed Conditions Of Load, Time And Temperature. The Penetration Is Expressed In Distance Of Tenths Of Millimeters Vertically Penetrated By A Standard Needle. The Standard Penetrometer Is Ruggedly Constructed, With An Aluminium Base Table With Levelling Screws, Platedvertical Rod, “Micrometric Vertical Adjustment Device”.The Slider Is Brass Made With Free Fall.The Digital Readout Of The Penetration Values Has Readings In Mm And Inch, With 0.01 Mm Resolution, Lcd 5 Digits Display, With Zero Set In Any Position.Power: 1.5V Battery.The Penetrometer Is Supplied With Stop And Release Push Button, Automatic Zero Set, Micrometer Adjustment, Set Of Weights 50 And 100 G Penetration Needle, Brass Sample Cups Diameter 55X35 Mm And 70X45 Mm.Dimensions: 220X170x410 Mmweight: 11 Kg Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 45 Providing, Supplying, Commissioning And Demonstration Of Digital Penetrometer Zi 4008 Or Equvalentstandards: Is 310, 1203, 1448, Ip 60, 49, 50 Astm D5, 217, D637, Bs 2000-49Specification: Same As Zi 4007 But The Unit Is Compact With Timer To Control Duration Of Penetration. The Instrument Is Provided With Lead Screw Gear Arrangement, Leveling Screws, Spirit Level And A Digital Preset Timer Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 46 Providing, Supplying, Commissioning And Demonstration Ofstripping Value Apparatus, Zi 4012 Or Equivalent Make With Standards: Specification:A Circular Tray Rotates In A Vertical Plane At A Rate Of Approximately 100 R.P.M. By An Electrical Geared Motor. 4 Bottles Of Approximately 400 Cc Are Mounted On This Circular Tray At An Angle Of 900. To Each Other With Their Mouth Towards Center Of The Tray. A Time Switch Is Provided. Suitable For Operation On 230 V A.C. Single Phase.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 47 Providing, Supplying, Commissioning And Demonstration Of Core Cutting / Core Drilling Machine ( Petrol ) Model Nozi 6001 With 100Mm Core Bit Or Equivqlent Makespecification:Suitable To Cut / Drill Cores Of Concrete, Rocks, Stones, Tiles Or The Similar Materials. The Machine Is Suitable For Core Samples Of Size Upto 150Mm Diameter With The Help Of Thin Walled Diamond Bits Which Are At Extra Cost. The Machine Has Sturdy Base With Pillar Support In Which Rack And Pinion Is Provided For Adjustment In Height And Penetration Assembly. The Leveling Screws Are Provided At The Base. For Gripping The Sample In Position Suitable Grips Are Provided. A Suitable Petrol Engine Is Fitted In The Machine With Cooling Arrangement With Water. The Base Frame Is Also Fitted With Wheels For Ease Of Transportation.Dimension Approx, Are As Under:Height: 1300 Mmbase: 625 X 900 Mmhead Travel On Rack: 500Mmdrill Speeds : 900 R.P.M. For Soft Samples And 350 R.P.M. For Hard Sampleswater Swivel : Built In The Machines.Accessories: ( 1 ) Thin Wall Diamond Bits. ( 2 ) Core Barrel. ( 3 ) Petrol Engine Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 48 Providing & Supplying Core Bit 4 Made In Germany : Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 49 Providing & Supplying Core Bit 6 Made In Germany : Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 50 Providing, Supplying, Commissioning And Demonstration Of Absolute Viscometer Bath Zi 4017 Or Equivalentspecification:This Bath Is Designed And Developed Under The Strict Supervision Of Our Experienced Professionals In Accordance With The International Quality Standards. Our Offered Bath Is Thoroughly Checked On Various Parametersto Ensure Zero-Defect. This Bath Is Widely Used In National Laboratories And Pharmaceutical Industries.Features:•Intelligent Signal Sampling For Accurate Data Measuring And Parameter Reading•Accurate Viscometer For Improving Experimental Efficiency•High Precision Digital Display•Ideal For Controlling The Temperature Accuracy•Durable Glass Bath For Optimum Heat Preservation•Desktop Based All-In-One Design For Easy Operations And Portability•Electric Stirrer For Ensuring Uniform Temperature Of Bath•Easy Cleaning And Drying Of Viscometer Tubesother Information:The Accompanying Absolute Kinematic Viscosity Bath Are Utilized To Measure Supreme Thickness Of Consistency Reviewed Clearing Bitumen ( Is:73:2006 ) At 160°C As Per Is:1206 ( Part Ii ) ( Like Astm D 2171 ) , Which Utilizes A Vacuum Slender Viscometer. Complete Absolute Viscosity Testing Equipment Adjusting To Is: 1206 ( Part Ii ) Method For Testing Tar And Bitumen Materials: 51 Determination Of Absolute Viscosity With The Accompanying Segments:Consistent Temperature Bath – A Suitable Shower For Drenching Of No Less Than 2 Vacuum Fine Viscometer Tubes With A Computerized Temperature Controller. The Precision Of The Temperature In The Shower Will Be + 0.1Oc All Through The Showermake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 52 Providing, Supplying, Viscosity Tube For Absolute Viscometer Bath With Calibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 53 Providing, Supplying, Commissioning And Demonstration Of Flash Point ( Closed ) Pensky-Martens Apparatusspecification:For Determining The Flash Point Of Fuels Oil And Lubricating Oil, Bitumen Other Than Cutback Bitumen And Suspension Of Solids In Liquids, Having A Flash Point Above 49ºc.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 54 Providing, Supplying, Commissioning And Demonstration Of Standard Tar Viscometer Specification:For Determining The Viscosity Of Cut Back Bitumen And Road Oil. The Viscometer Consists Of A Chrome Plated Copper Bath, With A Drain Valve And A Central Tube To Receive The Test Cup And To Position The Stirrer, And Is Mounted On A Stand With Levelling Feet. Stirrer Has A Curved Shield And Is Provided With An Insulated Handle, Thermometer Socket And Swivel Support For The Valve Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 55 Providing, Supplying, Commissioning And Demonstration Of Temperature Controller With Nablcalibration Certificate Size : 16X12x10”Standards Specification:Double Walled Inner Chamber In Stainless Steel Outer Chamber In Mild Steel Temperature Range Ambient To 100° C Controlled By The Capillary Thermostat. Accuracy ± 2° C, Least Count ±0.1° C.& Fhp Motor Cum Stirrer. Operated On 230V A.C. Single Phase. Heaters Are Provided According To The Size Of The Chamber. A Control Panel In Which The Digital Controller, Switches For Mains, Fhp Stirrer, A Regulator For The Stirrer Is Fit Is By The Side. These Baths Are Suitable For Washing Marshall Specimen. The Lid Is Made Up Of Stainless Steel With A Hole For Glass Thermometer To Penetrate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 56 Providing, Supplying, Commissioning And Demonstration Of Tile Abrasion Testing Machine Is 1237 This Is Used For Determination Of Resistance To Wear For Cement Concrete Flooring Tiles. Tiles Specimen Of Size 7.06 Cm X 7.06 Cm Is Pressed Face-Wise Under Specific Load On A Grinding Path And Abrasive Powder Is Evenly Spread On The Rotating Grinding Disc The Second Parallel Side Of The Tile Is Subjected To Wear For Similar Number Of Rotations. The Wear Of The Tile Is Measured On A Thickness Gauge Specifically Made For The Purpose. The Machine Consists Of A Disc Rotating At A Speed Of 30 R.P.M. In A Circular Tray. A Bracket Is Provided To Hold The Specimen. A Counter Balance Lever Loads The Specimen. Load Applied Is 30 Kgf. A Funnel Is Fitted To Evenly Spread Abrasive Powder On The Grinding Path. A Pre-Set Counter Automatically Stops The Machine After 22 Revolutions. This Counter Is Re-Adjustable. The Machine Works On 440 V A.C. Three Phase Electrical Supply. On Request Machine To Operate On 230 V A. C. Supply Can Also Be Suppliedmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 57 Providing, Supplying, Commissioning And Demonstration Of Hot Plate ( Rectangular ) Rectangular Hot Plate With Outer M.S. Sheet Body Duly Powder Coated Stove Painted To Work On 230 V Ac Supply. Useful For Continuous Heating Up To 300° C. Heavy Duty Cast Iron Top With Heat Resistant Paint. Hot Plate Size Rating 12 X 14 X 6Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 58 Providing, Supplying, Commissioning And Demonstration Of Digital Thermometer With Nablcalibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 59 Providing, Supplying, Commissioning And Demonstration Of Infrared Thermometer With Nablcalibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 60 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 600 Gm Capacity Accuracy 0.01 Gmdual Display Battery Cum Electrically Operated With Calibration Certificate. 61 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 1000 Gm Capacity Accuracy 0.01 Gmdual Display Battery Cum Electrically Operated With Calibration Certificate. 62 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 5 Kg Capacity Accuracy 0.1 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate. 63 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 30 Kg Capacity Accuracy 2 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate . 64 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 100 Kg Capacity Accuracy 10 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate. 65 Providing, Supplying, Zi 4014-A Filter Paper Discs, Set Of 25 66 Providing, Supplying, Commissioning And Demonstration Of Laboratory Cement Autoclave Zi 1016 Or Equivallentstandards:Is 4031-1968, Is 1624-1960 & Astm C 151, C 141Specification:The Autoclave Is Suitable For Conducting Accelerated Soundness Tests On Cements Or The Autoclave Expansion Test Requiring Constant Steam Pressure With The Correspondent Constant Pressure. It Consists Of A Stainless Steel Cylinder With A Welded Heat Insulated Metal Housing Attractively Finished. The Attached Control Unit Encloses A Sensitive Pressure Regulator And Pressure Gauge. Power Switches And Pilot Lights For Controlling The Electric Heating Units. Inside Chamber Dimensions 15.0 Cm Diameter X 40.5Cm Height Suitable For Operation On 230 V, 50 Hz Single Phase A. C. Supply. Supplied Complete With Test Bar Holder, Special Rack To Hold Specimens Above Water Level In The Autoclave And In A Vertical Position To Expose Them In The Same Manner. A Digital Pid Controller Is Fitted For Controlling The Desired Temperature. 67 Providing, Supplying, Auto Clave Mould 282 X25x25 Mm As Per Is Or Equviallent Make. 68 Providing, Supplying, Zi 2027A50 Mm Plastic Abs Cube Mould 69 Providing, Supplying, Zi 2027B70.6 Mm Plastic Abs Cube Mould 70 Providing, Supplying, Zi 2024B Cube Mould ( Cast Iron - For Mortar ) 50Mm, Three Gang As Per Is Or Equviallent Make. 71 Providing, Supplying, Zi 2024C Cube Mould ( Mild Steel - For Cement ) 70.6Mm, With Loose Base Plate As Per Is Or Equviallent Make. 72 Providing, Supplying, Commissioning And Demonstration Ofaccelerated Curing Tank With Cooling Arrangement Zi 2045B Or Equvallentstandards:Specification:Curing Tank Or Concrete Curing Tank Is Used For The Curing Of Concrete Samples For At Least 8 Hours. The Purpose Of Curing Is To Ensure That All Concrete Samples Are Similar With Regards To Quality And Strength.24 Hour Cycle From Time Of Mixing.Controlled 35° C Or 100° C ± 2° C Curing Temperature For Concrete.Controlled 27° C ± 2° C Curing Temperature For Grey Cement.This Curing Tank Has Been Designed To Accommodate 150Mm / 70.6Mm Cube Moulds And Upto 12 / 24Cube Mould Can Be Cured In One Go. The Tank Is Fully Insulated, Comes Complete With A Hinged Lid, Heater, Thermostat And Re-Circulated Pump. Provision Of Two Removable Racks Allows Free Circulation Of Water Around Each Mould. The Pump, Drain Valves And Electrical Equipment Are Housed In A Compartment Located At One End Of The Tank. The Tank Is Heated By An Immersion Heater Under Normal Conditions And Refrigeration System For Grey Cement The Temperature Is Controlled At 35° C Or 100° C ± 2° C / 27° C +2° C, Expect For The 15 Minutes After Immersion Of The Freshly Made Specimens. Accelerated Curing Tank With Cooling Arrangement Is Also Available. 73 Providing, Supplying, Commissioning Of Fridge 407L 3 Star Frost-Free Digital Inverter Double Door Refrigeratorconvertibleof Make Samsung / Lg / Whirlfool Etc 74 Carriage Of Materials From Chennai Port To Port Blair Central Lab ( As The Quottation Given By Zeal Internatiol Up To Chennai Port )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Andaman And Nicobar Islands View Result →
50.
Drinking Water Supply and Sanitation #10490507 Price Bid
Nit No. 17 ( 21-22 ) / Cwa ( Wns ) Ii Hp / Item No. 03 Procurement Of Visi Cooler / Lab. Refrigerator ( 2-8 Degree Celsius ) For Storing Water / Waste Water Samples As Bis1 With Rfid Card System. , Visi Cooler / Lab. Refrigerator ( 2-8 Degree C ) For Storing Water / Waste Water Samples As Per Bis1 With Rfid Card System ( 400 Litres ) . Specification For Visi Cooler / Lab Refrigerator ( 2 To 8-Degree C ) For Storing Water / Waste Water Samples As Per Bis 1 With Rfid Card System. Make: - Krish, Helmer, Walometra, Bhv Medical, Thermo Scientific Machine Shall Be Made And Design To Store Water And Waste Water Samples. Temperature Range Will Be +2°C To +8°C With Storage Volume Of 400 Lit Or More. The Refrigeration System Shall Be By Forced Air Circulation. Defrost Method Should Be Automatic. Refrigerant Should Be Cfc Free. Uniformity Should Be + / -1.5°C. Machine Should Have Color Touch Screen Panel For Control And Operation. Machine Shall Be Microprocessor Controlled Operate / Open Through Rfid Card Or By Password With Touch Screen Display. Includes Usb Port For Data Retrieval. High / Low Alarms Door Ajar Alarm, Condenser Temperature Alarm Should Be Present. All Activities Taken Place In The Machine Or Opening Or Closing Of Door Shall Be Recorded Through Software That Can Also Downloadable Via Usb. Machine Shall Have Min-Max Feature Enabling Users To View The Minimum And Maximum-Recorded Temperatures On The Home Screen. This Makes It Easier To Document. Refrigerator Shall Have Minimum 20 Hour Display And Alarm Battery Back-Up For Touch Screen ( Rechargeable 12V, Lead Acid Battery ) . There Will Be Glass Door For Easy Visibility Of Stored Items. Minimum Of 40Mm-50Mm Non-Cfc Foamed Insulation. Machine Shall Have Rust Proof Anti Scratch Powder Coating. Machine Shall Have Rfid Card Lock System. Machine Shall Have Storage Capacity For 4 To 5 Ss 304 Shelves / Drawer. Machine Shall Have Four Castor Wheels With Front Wheels With Lock. Manufacturer Should Be Ce / Iso / Iec 61010 Certified. Machine Shall Have 3 Year Warranty. , Visi Cooler / Lab. Refrigerator ( 2-8 Degree C ) For Storing Water / Waste Water Samples As Per Bis1 With Rfid Card System ( 300 Litres ) . Specification For Visi Cooler / Lab Refrigerator ( 2 To 8-Degree C ) For Storing Water / Waste Water Samples As Per Bis 1 With Rfid Card System. Make: - Krish, Helmer, Walometra, Bhv Medical, Thermo Scientific Machine Shall Be Made And Design To Store Water And Waste Water Samples. Temperature Range Will Be +2°C To +8°C With Storage Volume Of 300 Lit Or More. The Refrigeration System Shall Be By Forced Air Circulation. Defrost Method Should Be Automatic. Refrigerant Should Be Cfc Free. Uniformity Should Be + / -1.5°C. Machine Should Have Color Touch Screen Panel For Control And Operation. Machine Shall Be Microprocessor Controlled Operate / Open Through Rfid Card Or By Password With Touch Screen Display. Includes Usb Port For Data Retrieval. High / Low Alarms Door Ajar Alarm, Condenser Temperature Alarm Should Be Present. All Activities Taken Place In The Machine Or Opening Or Closing Of Door Shall Be Recorded Through Software That Can Also Downloadable Via Usb. Machine Shall Have Min-Max Feature Enabling Users To View The Minimum And Maximum-Recorded Temperatures On The Home Screen. This Makes It Easier To Document. Refrigerator Shall Have Minimum 20 Hour Display And Alarm Battery Back-Up For Touch Screen ( Rechargeable 12V, Lead Acid Battery ) . There Will Be Glass Door For Easy Visibility Of Stored Items. Minimum Of 40Mm-50Mm Non-Cfc Foamed Insulation. Machine Shall Have Rust Proof Anti Scratch Powder Coating. Machine Shall Have Rfid Card Lock System. Machine Shall Have Storage Capacity For 4 To 5 Ss 304 Shelves / Drawer. Machine Shall Have Four Castor Wheels With Front Wheels With Lock. Manufacturer Should Be Ce / Iso / Iec 61010 Certified. Machine Shall Have 3 Year Warranty. , Visi Cooler / Lab. Refrigerator ( 2-8 Degree C ) For Storing Water / Waste Water Samples As Per Bis1 With Rfid Card System ( 195 Litres ) . Specification For Visi Cooler / Lab Refrigerator ( 2 To 8-Degree C ) For Storing Water / Waste Water Samples As Per Bis 1 With Rfid Card System. Make: - Krish, Helmer, Walometra, Bhv Medical, Thermo Scientific Machine Shall Be Made And Design To Store Water And Waste Water Samples. Temperature Range Will Be +2°C To +8°C With Storage Volume Of 195 Lit Or More. The Refrigeration System Shall Be By Forced Air Circulation. Defrost Method Should Be Automatic. Refrigerant Should Be Cfc Free. Uniformity Should Be + / -1.5°C. Machine Should Have Color Touch Screen Panel For Control And Operation. Machine Shall Be Microprocessor Controlled Operate / Open Through Rfid Card Or By Password With Touch Screen Display. Includes Usb Port For Data Retrieval. High / Low Alarms Door Ajar Alarm, Condenser Temperature Alarm Should Be Present. All Activities Taken Place In The Machine Or Opening Or Closing Of Door Shall Be Recorded Through Software That Can Also Downloadable Via Usb. Machine Shall Have Min-Max Feature Enabling Users To View The Minimum And Maximum-Recorded Temperatures On The Home Screen. This Makes It Easier To Document. Refrigerator Shall Have Minimum 20 Hour Display And Alarm Battery Back-Up For Touch Screen ( Rechargeable 12V, Lead Acid Battery ) . There Will Be Glass Door For Easy Visibility Of Stored Items. Minimum Of 40Mm-50Mm Non-Cfc Foamed Insulation. Machine Shall Have Rust Proof Anti Scratch Powder Coating. Machine Shall Have Rfid Card Lock System. Machine Shall Have Storage Capacity For 4 To 5 Ss 304 Shelves / Drawer. Machine Shall Have Four Castor Wheels With Front Wheels With Lock. Manufacturer Should Be Ce / Iso / Iec 61010 Certified. Machine Shall Have 3 Year Warranty. , Description Refrigerator ( 300 Litres ) Volume : Net Total ( Liter ) : 300 L To 10 L Freezer : 72 L To 4 L Refrigerator : 228 L To 10 L Gross Total ( Liter ) : 324 L To 12 L Dimensions Width ( Mm ) : 600 Mm + 20 Mm Height With Hinge ( Mm ) : 1635 Mm + 20 Mm Depth With Door Handle ( Mm ) : 672 Mm + 20 Mm Depth With Door: 672 Mm + 20 Mm Weight : Net Weight ( Kg ) : 56 Kg + 5 Kg Features 1. 5 Mode Smart Conversion 2. Power Cool Function 3. Power Freeze Function 4. No Frost 5. Fulti Flow 6. Deodorizer Number Of Shelf ( Total ) : 3Ea Shelf Material : Tempered Glass Bottom Basket : 1 Ea Number Of Door Pocket : 4 Ea Energy Star Rating : 2 Star
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
TenderDetail
Loading tenders