Renovation To Existing Polyhouse Div. Of Plant Pathology At Iihr, Hessaraghatta - 1. Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish Lead Upto 50 M And Lift Upto 1.50 M All Kinds Of Soil 2 Excavation Work In Foundation Trenches Or Drains Not Exceeding 1.5 M In Width Or 10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. For Curtain Walls For Vertical Pipes 3 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering – All Work Upto Plinth Level, 1:4:8 ( 1 Cement : 4 Coarse Sand: 10 Graded Stone Aggregate 40Mm Nominal Size ) For Foundation Bed Of Curtain Walls 4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering – All Work Upto Plinth Level, 1:3:6 ( 1 Cement: 3 Coarse Sand: 6 Graded Stone Aggregate 20Mm Nominal Size ) For Vertical Members And As Dpc On Solid Block Masonry 5 Providing And Constructing Concrete Block Masonry Using 150X200x400 Mm Solid Core Compact Concrete Block ( Grade C - 35Kg / Cm2 ) In Cm 1:6 Including All Scaffolding, Curing, Etc. Complete. ( Curtain Walls ) 6 Supplying And Erecting Superstructure Framework. : The Work Shall Include Cutting, Threading, Welding, Fixing, Hoisting, Grinding, Finishing, Painting Joints With Zinc Rich Primer Etc Complete. Complete As Per Directions: Gi Pipes ( ‘B’ Class Isi- Medium, 1239 ) A.60Mm Od Gi Pipes For Vertical Member Including Foundation At Minimum Weight 4.1 Kg / Per Meter X 76 Rmt B.48Mm Od Gi Pipes For Cross Brazing At Minimum Weight 2.30 Kg / Per Meter X 48Rmt C.48Mm Od Gi Pipes For Top Purlin And Horizontal At Minimum Weight 2.30 Kg / Per Meter X 150Rmt D.48Mm Od Gi Pipes For Roof Truss At Minimum Weight 2.30 Kg / Per Meter X 65Rmt E.48Mm Od Gi Pipes For Internal Ties At Minimum Weight 2.30 Kg / Per Meter X 30Rmt H. 48Mm Od Gi Pipes For Near Fans At Minimum Weight 2.30 Kg / Per Meter X 10Rmt I. 48Mm Od Gi Pipes For Door At Minimum Weight 2.30 Kg / Per Meter X 22Rmt J. 48Mm Od Gi Pipes For Anti Room At Minimum Weight 2.30 Kg / Per Meter X 25Rmt 7 Providing And Fixing In Position 50Perc. Cutoff Green Hdpe Woven Retractable Shade Net With All Edge Stitching With Plastic Tape, Including All Gi Wires, Pulleys, Nylon Ropes, Ss Rings Etc., Complete As Per Directions At Roof Level. 8 Supplying And Fixing In Position 100Mm Thick Cross Fluted Cellulose Pad ( Celdek ) Cool Cell Cooling Pad With Necessary Cover Pipes For Water Circulation & Back Flow Drain, All Connection Including Providing 1, 000 Lts Capacity Doubled Wall Pvc Tank Of Make Sintex / Fusion / Kaveri With Which Has To Placed Below Ground Level For Proper Circulation Of Water Back From Cooling Pad To The Tank, Including Providing An 0.50 Hp 1Phase Pump With Dol ( L&T ) Starter Isi Make With Necessary Wiring Etc, With Foot Valve Gate Vale And Necessary Electrical Connection In Parallel With Draft Fans And Misting System Necessary G.I. Pipe And Fitting For Water Circulation, Etc., Complete Supplying, Installing, Commissioning And Testing Of Direct Drive 3Phase Draft Fans Isi – Almonard / Bajaj / Khaitan / Usha / Crompton ) For Exhaust Of 900Mm Dia With Necessary Louvers Of Approved Quality And Size As Suitable For Greenhouse As Directed By The Engineer At Site With All Necessary Control Panel Having Dol L&T Starter And Mcb, Spp Enclosed In A Suitable Box With Stainless Steel Mesh, Locking Facility With All Necessary Electrical Wiring, Switches Etc Complete Including Integrating With The Existing Cooling System. Providing And Fixing Aluminium Grippers As Per Approved Sample Width All Necessary Screws, Drills Holes, Washers, Zigzag Spring., Etc., To Firmly Hold Shade Net As Directed At Site Fabrication And Erection Of Super Structure Labour For Fixing Of Polysheet , Net And Profile Finishing Walls With Water Proofing Cement Paint “Snowcem - Plus” Of M / S. Snowcem India Ltd. Or Equivalent Of Required Shade: New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) Glazing: With 200 Micron Uv Stabilized Ldpe Sheet ( Ipcl Or Equivalent Make ) Including All Clamps Screws Etc. Complete As Per Directions For Sides, Roof & Front, Back Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement:3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finish The Top Smooth. Supplying & Laying Of 25 Sq Mm X 4 Core Aluminium Conductor, Pvc Insulated, Wire Armored Ug Cable For Poly-House ( 1.1 Kv Class ) In Ground By Using Bricks & Sand As Per Indian Electricity Standards. ( Glow Star, Cci & Universal ) Supplying & Fixing Of 100A-4Pole Mcb ( Indo-Kopp, Havells, Standard ) With Metal Box. Supplying And Fixing Of 100Amps Capacity Three Phase Distribution Bus Bar Box Out Side Mounting As Required At Site As Per Ie Standard.