}

Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment, Electronic Products and Appliances, Audio Visual Equipments, Camera, Scientific Instrument, Universal Testing Machines, Scientific Equipment, Viewing and Observing Instruments,-Gujarat

Health And Family Welfare Department has published Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment, Electronic Products and Appliances, Audio Visual Equipments, Camera, Scientific Instrument, Universal Testing Machines, Scientific Equipment, Viewing and Observing Instruments,. Submission Date for this Tender is 05-05-2015. Medical Equipment Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

7474571
Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment, Electronic Products and Appliances, Audio Visual Equipments, Camera, Scientific Instrument, Universal Testing Machines, Scientific Equipment, Viewing and Observing Instruments,
Tender
Indian
Gujarat
05-05-2015

Tender Details

Providing Supply Of “Hospital Equipments/ Instruments Part-6” -1 Three-Chip Full Hd Camera Usfda Approved Head, , Progressive Scan, Soakable, Gas- And Plasma-Sterilizable, With Integrated Parfocal Zoom Lens, Focal Length F = 15 - 31 Mm (2X), 2 Freely Programmable Camera Head Buttons, 2 Link To The Master Camera Control : Link Module, For Use With Full Hd Three-Chip Camera Heads, Power Supply 100 - 120 Vac/200 - 240 Vac, 50/60 Hz, For Use With Processor 3 400 A Mains Cord, Length 300 Cm Tc 011 Link Cable, Length 20 Cm 4 26 Full Hd Monitor, Color Systems Pal/Ntsc, Max. Screen Resolution 1920 X 1080, Image Format 16:9, Video Inputs: Dvi, 3G-Sdi, Vga, S- Video, Composite, Video Outputs: Dvi, 3Gsdi, Composite, Power Supply 100 - 240 Vac, 50/60 Hz, 5 V Dc Output (1 A), Wall-Mounted With Vesa 100 Adaption, Including: External 24 Vdc Power Supply Mains Cord 5 Moniter Stand Suitable For 26 And Other Monitors, Basic Monitor Stand, Tiltable, Rotation +/- 30, Disinfectable, Color White, E.G. For Use With 26 Full Hd Monitor 9826 Nb Or 26 3D Monitor 9826 6 Master Camera Control Unit Connect Module, For Use With Up To 3 Link Modules, Resolution 1920 X 1080 Pixels, With Integrated Scb And Digital Image Processing Module, Power Supply 100 - 120 Vac/200 - 240 Vac, 50/60 Hz, Consisting Of: 7 400 A Mains Cord, Length 300 Cm 8 Dvi-D Connecting Cable, Length 300 Cm 9 Scb Connecting Cable, Length 100 Cm 10 Usb Flash Drive, 32 Gb 11 Usb Silicone Keyboard, With Touchpad, Us 12 Endoscopic Video Unit For Use With Telecam One-Chip Camera Heads And Video Endoscopes, Incl. 50 W Hilux Light Source, 15 Lcd Tft Screen, Usb/Sd Memory Module, Color Systems Pal/Ntsc, With Integrated Image Processing Module, Power Supply 100 - 240 Vac, 50/60 Hz, Consisting Of: 13 20040240Us Usb Silicone Keyboard, With Touchpad, Us Character Set 14 20040280 Usb Flash Drive, 4 Gb 15 400 F Mains Cord 16 400 B Mains Cord, Us Version 17 Cold Light Fountain Xenon With Integrated Scb, Including An Integrated Anti-Fog Pump, A 300 Watt Xenon Bulb And Light Connection, Power Supply 100 - 125/220 - 240 Vac, 50/60 Hz, 18 400 A Mains Cord 19 Connecting Cable, Length 100 Cm 20 Laproscopy Instruments For Hystroscopy Usfda Approved : Continuous-Flow Examination Sheath, Diameter 3.6 Mm, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Examination Sheath 21 Laproscopy Instruments For Hystroscopy Usfda Approved : Examination Sheath, Diameter 2.8 Mm, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Continuous-Flow Examination Sheath 22 Laproscopy Instruments For Hystroscopy Usfda Approved : Examination Sheath, Diameter2.8 Mm, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Cf Examination Sheath 23 Laproscopy Instruments For Hystroscopy Usfda Approved : Bettocchi® Continuous-Flow Operating Sheath, Size 4.2 Mm, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Operating Sheath 24 Laproscopy Instruments For Hystroscopy Usfda Approved : Bettocchi® Operating Sheath, Size 3.6 Mm, With Channel For Semirigid 5 Fr. Operating Instruments, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Cf Operating Sheath 25 Laproscopy Instruments For Hystroscopy Usfda Approved : Kilani Single-Flow Sheath, For Intrauterine Insemination And Embryo Transfer, Size 5.5 Mm, With Obturator And Working Channel For Wallace Catheter, For Use With Hopkins® Telescope 26 Laproscopy Instruments For Hystroscopy Usfda Approved : Biopsy And Grasping Forceps, Semirigid, Double Action Jaws, 5 Fr., Length 34 Cm 27 Laproscopy Instruments For Hystroscopy Usfda Approved : Scissors, Semirigid, Blunt, Single Action Jaws, 5 Fr., Length 34 Cm 28 Laproscopy Instruments For Hystroscopy Usfda Approved : Scissors, Semirigid, Pointed, Single Action Jaws, 5 Fr., Length 34 Cm 29 Laproscopy Instruments For Hystroscopy Usfda Approved : Punch, Semirigid, Throughcutting, Single Action Jaws, 5 Fr., Length 34 Cm 30 Laproscopy Instruments For Hystroscopy Usfda Approved : Biopsy Spoon Forceps, Semirigid, Double Action Jaws, 5 Fr., Length 34 Cm 31 Laproscopy Instruments For Hystroscopy Usfda Approved : Bettocchi® Myoma Fixation Instrument, Semirigid, 5 Fr., Length 34 Cm 32 Laproscopy Instruments For Hystroscopy Usfda Approved : Hesseling Tenaculum Grasping Forceps, Semirigid, Double Action Jaws, 5 Fr., Length 34 Cm 33 Laproscopy Instruments For Hystroscopy Usfda Approved : Working Element Set, Bipolar, Cutting By Means Of A Spring. Movable Thumb Support. In Rest Position The Electrode Tip Is Inside The Sheath., Consisting Of: Working Element 2X 26040 Gp Cutting Loop Coagulation Electrode, Pointed Coagulation Electrode, With Ball End Bipolar High Frequency Cord Protection Tube 34 Laproscopy Instruments For Hystroscopy Usfda Approved : Working Element, Bipolar, Cutting By Means Of A Finger Grip. Movable Thumb Support. In Resting Position, The Electrode Tip Is Outside The Sheath 35 Laproscopy Instruments For Hystroscopy Usfda Approved : Working Element Set, Bipolar, Cutting By Means Of A Finger Grip. Movable Thumb Support. In Rest Position The Electrode Tip Is Outside The Sheath., Consisting Of: Working Element 2X 26040 Gp Cutting Loop Coagulation Electrode, Pointed Coagulation Electrode, With Ball End Bipolar High Frequency Cord Protection Tube 36 Laproscopy Instruments For Hystroscopy Usfda Approved : Cutting Loop, Bipolar, 24 Fr., For Use With Telescope 37 Laproscopy Instruments For Hystroscopy Usfda Approved : Cutting Loop, Bipolar, Small, 24 Fr., For Use With Telescope 38 Laproscopy Instruments For Hystroscopy Usfda Approved : Coagulation Electrode, Bipolar, Ball End, 24 Fr., For Use With Telescope 39 Laproscopy Instruments For Hystroscopy Usfda Approved : Cutting Loop, Bipolar, Straight, 24 Fr., For Use With Telescopefor Sterilization And Storage Of Electrodes, Loops, Curettes And Knives 40 Laproscopy Instruments For Hystroscopy Usfda Approved : Protection Tube,41 Laproscopy Instruments For Hystroscopy Usfda Approved : Metal Container For Sterilizing And Storage, With Perforations And Laid-In Textile Filters In Lid And Bottom, With Strips Of Silicone Knobs, For Single-Level Storage, External Dimensions (W X D X H): 280 X 195 X 50 Mm 42 Laproscopy Instruments For Hystroscopy Usfda Approved : Metal Container For Sterilizing And Storage, With Perforations And Laid-In Textile Filters In Lid And Bottom, With Strips Of Silicone Knobs, For Two-Level Storage, External Dimensions (W X D X H): 280 X 195 X 65 Mm 43 Laproscopy Instruments For Hystroscopy Usfda Approved : Metal Container For Sterilizing And Storage, With Perforations And Laid-In Textile Filters In Lid And Bottom, With Silicone Bridges, For Single-Level Storage, External Dimensions (W X D X H): 280 X 195 X 55 Mm 44 Laproscopy Instruments For Hystroscopy Usfda Approved : Wire Tray For Cleaning, Sterilization And Storage, Of Two Rigid Endoscopes And One Light Cable, Including Holder External Dimensions (W X D X H): 352 X 125 X 54 Mm, For Rigid Endoscopes Up To Diameter 10 Mm And Working Length 20 Cm45 Three-Chip Full Hd Camera Head, Usfda Approved50/60 Hz, Progressive Scan, Soakable, Gas- And Plasma-Sterilizable, With Integrated Parfocal Zoom Lens, Focal Length F = 15 - 31 Mm (2X), 2 Freely Programmable Camera Head Buttons, For Use With Image 1 Spies™ And Image 46 Hd Camera Control Unit Scb, With Sdi Module, Usfda Approvedfor Use Standard One- And Three-Chip Camera Heads, Max. Resolution 1920 X 1080 Pixels, With Integrated Sdi (Serial Digital Interface) Module, Scb And Digital Image Processing Module, Color Systems Pal/Ntsc, Power Supply 100 - 240 Vac, 50/60 Hz, Scb, With Sdi Module 400 A Mains Cord 536 Mk Bnc/Bnc Video Cable 547 S S-Video (Y/C) Connecting Cable Special Rgbs Connecting Cable Connecting Cable, For Controlling Peripheral Units Dvi-D Connecting Cable ,Scb Connecting Cable Keyboard, With Us English Character Set 47 Wire Tray For Cleaning, Sterilization And Storage, Of E.G. Pecd-Endoscope 8163 Pcd, Including Cleaning Adaptor For Washer-Disinfector, With Lid, Spare Parts Basket 39501 Xs And Silicone Telescope Holders, External Dimensions (W X D X H): 460 X 150 X 80 Mm, For Instruments With Up To 27 Cm Working Length 48 Hopkins® Forward-Oblique Telescope 30°, Usfda Approved Diameter 2 Mm, Length 26 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated 49 Hopkins® Forward-Oblique Telescope 30°, Usfda Approved Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated, 50 Examination Sheath, Diameter 5.2 Mm, With 1 Luer-Lock Adaptor, For Use With Continuous- Flow Examination Sheath 51 Continuous-Flow Examination Sheath, Diameter 6.2 Mm, With 1 Luer-Lock Adaptor, For Use With 52 Bettocchi® Operating Sheath, Size 5.4 Mm, With Channel For Semirigid 5 Fr. Operating Instruments, With 1 Stopcock And 1 Luer-Lock Adaptor, For Use With Continuous-Flow Operating Sheath 53 Bettocchi® Continuous-Flow Operating Sheath, Size 6 Mm, With 1 Stopcock And 1 Luerlock Adaptor, For Use With Operating Sheath 54 Scissors, Semirigid, Blunt, Single Action Jaws, 5 Fr., Length 34 Cm 55 Scissors, Semirigid, Pointed, Single Action Jaws, 5 Fr., Length 34 Cm 56 Biopsy And Grasping Forceps, Semirigid, Double Action Jaws, 5 Fr., Length 34 Cm 57 Bettocchi® Needle Electrode, Unipolar, 5 Fr., Length 34 Cm 58 Ball Electrode, Unipolar, 5 Fr., Length 53 Cm 59 Bipolar Dissection Electrode, Semirigid, 5 Fr., Length 36 Cm 60 Bettocchi® Myoma Fixation Instrument, Semirigid, 5 Fr., Length 34 Cm 61 Bettocchi® Palpation Probe, Semirigid, Scaled, 5 Fr., Length 34 Cm 62 Bettocchi® Polypectomy Loop, Unipolar, 5 Fr., Length 34 Cm 63 Resectoscope Sheath, Irrigation And Suction, 26 Fr., Oblique Beak, Rotatable Inner Sheath With Ceramic Insulation, For Use With Including Connecting Tube For In- And Outflow, For Continuous Working Elements 64 Standard Obturator, For Use With Resectoscope Sheaths 65 Working Element Set, Cutting By Means Of A Spring. Movable Thumb Ring. In Rest Position The Tipe Of The Electrode Is Inside The Sheath Working Element Consists Ofcutting Loop, Angled Coagulation Electrode, Ball End, Diameter 3 Mm Coagulation Electrode, Ball End, Diameter 5 Mm Coagulating Needle Electrode, Angled Unipolar High Frequency Cord Protection Tube, For Sterilization And Storage Of Electrodes, Curettes And Knives 66 Working Element Set, Bipolar, Cutting By Means Of A Spring. Movable Thumb Support. In Rest Position The Electrode Tip Is Inside The Sheath., Consisting Of: Working Element 2X 26040 Gp Cutting Loop Coagulation Electrode, Pointed Coagulation Electrode, With Ball End Bipolar High Frequency Cord Protection Tube 67 Cutting Loop, Straight, 24 Fr., For Use With Resectoscope Sheaths 68 Roller Electrode, Cylindrical, 24 Fr., Diameter 3 Mm For Use With Resectoscope Sheaths 69 Roller Electrode, Cylindrical, 24 Fr., Diameter 5 Mm For Use With Resectoscope Sheaths 70 Coagulation Electrode, Pointed, 24 Fr., For Use With Resectoscope Sheaths 71 Lozzi Needle Electrode, 24 Fr., For Use With Resectoscope Sheaths 72 Coagulation Electrode, Bipolar, Ball End, 24 Fr., For Use With Hopkins® Telescope 73 Cutting Electrode, Bipolar, Pointed, 24 Fr., For Use With Hopkins® Telescope 74 Cutting Loop, Bipolar, 24 Fr., For Use With Hopkins® Telescope 75 Cutting Loop, Bipolar, Straight, 24 Fr., For Use With Hopkins® 76 Hamou® Endomat® Scb, Power Supply 100 - 240 Vac, 50/60 Hz System Requirements For Use With Scb-Pc: Scb R-Ui Software Release V20090001-17 Or Higher, Consisting Of: Lap Tubing Set, Puncture Cannulas Scb Connecting Cable, Length 100 Cm Vacusafe Promotion Pack, 2 L, Luer-Lock77 Hyst Tubing Set, Reusable, Sterilizable 78 Lap Tubing Set, Reusable, Sterilizable, Included In Delivery: Lap Pressure Dome Lap Silicone Tubing Set Pump Tubing Lap Inflow Tube, With Y-Adaptor 79 One-Pedal Footswitch, Digital, One-Stage 80 Silicone Tubing Set, For Suction, Sterilizable81 Suction Bottle, Sterilizable 5 L, Bottle Cap, For Suction Bottles 1.5 L And 5 L, Sterilizable 82 Bottle Stand, For Suction Bottle 5 L 83 Resection Module And Bivascular, Usfda Approvedpower Supply 220 - 240 Vac, 50/60 Hz, Hf Connecting Sockets: Bipolar Combination Bipolar Multifunction Unipolar 3-Pin + Erbe Neutral Electrode Combination 6.3 Mm Jack And 2-Pin, Including Additional Resection Model Software Bi-Vascular-Safe Mode System Requirements: Scb R-Ui Software Release 400 A Mains Cord Scb Connecting Cable, Length 100 Cm 84 Two-Pedal Footswitch 85 Bipolar High Frequency Cord, 86 Cold Light Fountain Xenon For Indocyaininn Perfusion Assesmentwith Integrated Scb, Including An Integrated Anti-Fog Pump, A 300 Watt Xenon Bulb And Light Connection, Power Supply 100 - 125/220 - 240 Vac, 50/60 Hz, 87 Straight Forward Telescope 0º, Enlarged View, Diameter 10 Mm, Length 31 Cm, Autoclavable, For Indocyanin Green (Icg) And Autofluorescence (Af), Fiber Optic Light Transmission Incorporated, Color Code: Green 88 Forward-Oblique Telescope 30º, Enlarged View, Diameter 10 Mm, Length 31 Cm, Autoclavable, For Indocyanin Green (Icg) And Autofluorescence (Af), Fiber Optic Light Transmission Incorporated, Color Code: Red 89 Three-Chip Full Hd Camera Head, Usfda Approved Compatible, For Perfusion Diagnosis Of Tissues And Organs With Indocyanine Green (Icg) In Conjunction With Light Source D-Light P, Progressive Scan, With Integrated Parfocal Zoom Lens, Focal Length F = 15-31 Mm (2X), With 2 Freely Programmable Camera Head Buttons, 90 Straight Forward Telescope 0°, For Telescope Holding Deviceworking Distance 25 - 75 Cm, Diameter 10 Mm, Length 11 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated, 91 Fiber Optic Light Cable, For Telescope Holding Devicewith Straight Connector, Diameter 4.8 Mm, Length 300 Cm 92 Fiber Optic Light Cable, For Telescope Holding Devicewith 90° Deflection To The Instrument, Diameter 4.8 Mm, Length 300 Cm 93 Fiber Optic Light Cable, For Telescope Holding Devicewith 90° Deflection To The Instrument, Very Narrow Radius Of Curvature, Diameter 4.8 Mm, Length 300 Cm 94 Articulated Stand, For Telescope Holding Devicereinforced Version, L-Shaped, With One Central Clamp For All Five Joint Functions, Height 48 Cm, Operating Range 52 Cm, With Quick Release Coupling (Female) 95 Socket For Telescope Holding Device 96 Clamping Jaw, For Telescope Holding Devicemetal, Clamping Range 16.5 Up To 23 Mm, With Quick Release Coupling (Male), For Use With All Square-Headed 97 Clamping Cylinder, For Telescope Holding Devicefor Flexible Mounting Of 10 Mm Telescopes To Telescope Sheath, Autoclavable. The Clamping Cylinder Allows Vertical Movement And Rotation Of The Telescope. For Use With Clamping Jaw And As Well As Point Setter Universal Adaptor 10 - 15 Mm 98 Telescope Holding Device Distance Rod, Length 25 Cm 99 Adaptor, For Telescope Holding Device Autoclavable, Permits Telescope Changing Under Sterile Conditions 100 Illuminator, For Telescope Holding Device With 2 Adjustable Lenses And Holding Device For Telescope Holding Devicetelescopes, Autoclavable, For Use With Telescopes (20916020 And Equivalent Models) And Y-Fiber Optic Light Cable 495 Uv, Not Suitable For Use With Telescopes Of The 2Nd Generation With Integrated Illuminator 101 Double Channel Gastroscope, With Water Jet Channel, 12 Mm X 110 Cm, Color System Pal,/Ntscsheath Diameter 12 Mm, 2 Working Channels Diameter 2.8/3.4 Mm, Distal Tip Outer Diameter 12 Mm, Deflection Up 180°/200°, Deflection Down 100°, Deflection Left/Right 120°/120°, Field Of View 140°, Depth Of Field 2 - 200 Mm, Working Length 110 Cm, 102 Therapeutic Gastroscope, With Water Jet Channel, 12 Mm X 110 Cm, Color System Ntsc,/Palsheath Diameter 12 Mm, Working Channel Diameter 4.2 Mm, Distal Tip Outer Diameter 12 Mm, Deflection Up 180°/200°, Deflection Down 100°, Deflection Left/Right120°/120°, Field Of View 140°, Depth Of Field 2 - 200 Mm, Working Length 110 Cm, 103 Endoscopic Video Unit For Use With Telecam One-Chip Camera Heads And Video Endoscopes, Incl. 50 W Hilux Light Source, 15 Lcd Tft Screen, Usb/Sd Memory Module, Color Systems Pal/Ntsc, With Integrated Image Processing Module, Power Supply 100 - 240 Vac, 50/60 Hz, Consisting Of: Usb Silicone Keyboard, With Touchpad, Us Character Set 20040280 Usb Flash Drive, 4 Gb 400 F Mains Cord 400 B Mains Cord, Us Version 400 B Mains Cord, Us Version 104 Cold Light Fountain Xenon With Integrated Scb, Including An Integrated Anti-Fog Pump, A 300 Watt Xenon Bulb And Light Connection, Power Supply 100 - 125/220 - 240 Vac, 50/60 Hz, 400 A Mains Cord Connecting Cable, Length 100 Cm 105 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 1X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 120 Cm, For Use Withworking Channels As Of Size 3.2 Mm 106 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 2X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 120 Cm, For Use Withworking Channels As Of Size 3.2 Mm 107 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, Serrated,Diameter 2.5 Mm, Working Length 120 Cm, For Use Withworking Channels As Of Size 3.2 Mm 108 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Sharp, Diameter2.5 Mm, Working Length 120 Cm, For Use With Workingchannels As Of Size 3.2 Mm 109 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Blunt, Diameter2.5 Mm, Working Length 120 Cm, For Use With Workingchannels As Of Size 3.2 Mm 110 Grasping Forceps,Should Be Strictly Usfda Aprooved Reusable, Flexible, With 2 Spring-Action Jaws, 1X 2 Teeth, Sharp, Diameter 2.5 Mm, Working Length 160 Cm, For Use Withworking Channels As Of Size 3.2 Mm 111 Grasping Forceps,Should Be Strictly Usfda Aprooved Reusable, Flexible, With 2 Spring-Action Jaws, 2X 2 Teeth, Sharp, Diameter 2.5 Mm, Working Length 160 Cm, For Use Withworking Channels As Of Size 3.2 Mm 112 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, Serrated,Diameter 2.5 Mm, Working Length 160 Cm, For Use Withworking Channels As Of Size 3.2 Mm 113 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Sharp, Diameter2.5 Mm, Working Length 160 Cm, For Use With Workingchannels As Of Size 3.2 Mm 114 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Blunt, Diameter2.3 Mm, Working Length 160 Cm, For Use With Workingchannels As Of Size 2.8 Mm 115 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 1X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 200 Cm, For Use Withworking Channels As Of Size 3.2 Mm 116 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 2X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 200 Cm, For Use Withworking Channels As Of Size 3.2 Mm 117 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, Serrated,Diameter 2.5 Mm, Working Length 200 Cm, For Use Withworking Channels As Of Size 3.2 Mm 118 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Sharp, Diameter2.5 Mm, Working Length 200 Cm, For Use With Workingchannels As Of Size 3.2 Mm 119 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Blunt, Diameter2.5 Mm, Working Length 200 Cm, For Use With Workingchannels As Of Size 3.2 Mm 120 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 1X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 230 Cm, For Use Withworking121 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, 2X 2 Teeth, Sharp,Diameter 2.5 Mm, Working Length 230 Cm, For Use Withworking Channels As Of Size 3.2 Mm 122 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 2 Spring-Action Jaws, Serrated,Diameter 2.5 Mm, Working Length 230 Cm, For Use Withworking Channels As Ofsize 3.2 Mm 123 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Sharp, Diameter2.5 Mm, Working Length 230 Cm, For Use With Workingchannels As Size 3.2 Mm 124 Grasping Forceps,Should Be Strictly Usfda Aproovedreusable, Flexible, With 3 Spring-Action Claws, Blunt, Diameter2.5 Mm, Working Length 230 Cm, For Use With Workingchannels As Size 3.2 Mm 125 Biopsy Forceps,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Roundcupped Jaws, Fenestrated, Flexible, Double Action Jaws,Diameter 1.8 Mm, Working Length 160 Cm, For Use With Highfrequency Surgery Units, For Use With Working Channels As Ofsize 2.2 Mm 126 Spare Forceps,Should Be Strictly Usfda Aproovedinsulated, Reusable, Round Cupped Jaws, Fenestrated, Flexible,Double Action Jaws, Diameter 1.8 Mm, Working Length 160 Cm,For Use With Biopsy Forceps And Working Channelsas Of 2.2 Mm 127 Biopsy Forceps,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Roundcupped Jaws, Fenestrated, Flexible, Double Action Jaws,Diameter 1.8 Mm, Working Length 230 Cm, For Use With Highfrequency Surgery Units, For Use With Working Channels As Ofsize 2.2 Mm 128 Spare Forceps,Should Be Strictly Usfda Aproovedinsulated, Reusable, Round Cupped Jaws, Fenestrated, Flexible,Double Action Jaws, Diameter 1.8 Mm, Working Length 230 Cm,For Use With Biopsy Forceps And Working Channelsas Of Size 2.2 Mm 129 Biopsy Forceps,Should Be Strictly Usfda Aproovedcomplete, With Handle, Insulated, Reusable, Roundcupped Jaws, Fenestrated, Flexible, Double Action Jaws,Diameter 2.3 Mm, Working 160 Cm, For Use With Highfrequency Surgery Units, For Use With Working Channels As Ofsize Mm 130 Spare Forceps,Should Be Strictly Usfda Aproovedinsulated, Reusable, Round Cupped Jaws, Fenestrated, Flexible,Double Action Jaws, Diameter 2.3 Mm, Working Length 160 Cm,For Use With Biopsy Forceps And Working Channelsas Of Size 2.8 Mm 131 Biopsy Forceps,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Roundcupped Jaws, Fenestrated, Flexible, Double Action Jaws,Diameter 2.3 Mm, Working Length 230 Cm, For Use With Highfrequency Surgery Units, For Use With Working Channels As Ofsize 2.8 Mm 132 Spare Forceps,Should Be Strictly Usfda Aproovedinsulated, Reusable, Round Cupped Jaws, Fenestrated, Flexible,Double Action Jaws, Diameter 2.3 Mm, Working Length 230 Cm,For Use With Biopsy Forceps And Working Channelsas Of Size 2.8 Mm 133 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 25 Mm, Asymmetric, Diameter 2.4 Mm, Working Length120 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 134 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 25 Mm, Asymmetric, Workinglength 120 Cm, For Use With Polypectomy Snare And Working Channels Of Size 2.8 Mm 135 Spare Tube,Should Be Strictly Usfda Aproovedinsulated, Reusable, For Asymmetric Snares, Diameter 2.4 Mm,Working Length 120 Cm, For Use With Polypectomy Snare 136 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 25 Mm, Asymmetric, Diameter 2.4 Mm, Working Length160 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 137 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 25 Mm, Asymmetric, Workinglength 160 Cm, For Use With Polypectomy Snare And Working Channels Of 2.8 Mm 138 Spare Tube,Should Be Strictly Usfda Aproovedinsulated, Reusable, For Asymmetric Snares, Diameter 2.4 Mm,Working Length 160 Cm, For Use With Polypectomy Snare 139 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 25 Mm, Asymmetric, Diameter 2.4 Mm, Working Length200 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 140 Spare Snare,Should Be Strictly Usfda Aprooved Insulated, Reusable, Snare Size 25 Mm, Asymmetric, Workinglength 200 Cm, For Use With Polypectomy Snare And Working Channels Of 2.8 Mm 141 Spare Tube,Should Be Strictly Usfda Aproovedinsulated, Reusable, For Asymmetric Snares, Diameter 2.4 Mm,Working Length 200 Cm, For Use With Polypectomy Snare 142 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 40 Mm, Asymmetric, Diameter 2.4 Mm, Working Length160 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 143 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 40 Mm, Asymmetric, Workinglength 160 Cm, For Use With Polypectomy Snare And Working Channels Of 2.8 Mm 144 Spare Tube,Should Be Strictly Usfda Aproovedinsulated, Reusable, For Asymmetric Snares, Diameter 2.4 Mm,Working Length 160 Cm, For Use With Polypectomy Snares145 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 40 Mm, Asymmetric, Diameter 2.4 Mm, Working Length200 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 146 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 40 Mm, Asymmetric, Workinglength 200 Cm, For Use With Polypectomy Snare And Working Channels As Of 2.8 Mm 147 Spare Tube,Should Be Strictly Usfda Aproovedinsulated, Reusable, For Asymmetric Snares, Diameter 2.4 Mm,Working Length 200 Cm 148 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 60 Mm, Asymmetric, Diameter 2.4 Mm, Working Length160 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 149 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 60 Mm, Asymmetric, Workinglength 160 Cm, For Use With Polypectomy Snare And With Working Channels As Of 2.8 Mm 150 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle 13774 H, Insulated, Reusable, Snaresize 60 Mm, Asymmetric, Diameter 2.4 Mm, Working Length200 Cm, For Use With High Frequency Surgery Units, For Usewith Working Channels As Of Size 2.8 Mm 151 Spare Snare,Should Be Strictly Usfda Aproovedinsulated, Reusable, Snare Size 60 Mm, Asymmetric, Workinglength 200 Cm, For Use With Polypectomy Snare And With Working Channels As Of 2.8 Mm 152 Handle,Should Be Strictly Usfda Aproovedonly, Reusable 153 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 25 Mm, Oval, Diameter 2.3 Mm, Working Length 150 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 154 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 15 Mm, Oval, Diameter 2.3 Mm, Working Length 150 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 155 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 25 Mm, Oval, Diameter 2.3 Mm, Working Length 250 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 156 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 15 Mm, Oval, Diameter 2.3 Mm, Working Length 250 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 157 Spare Snare,Should Be Strictly Usfda Aproovedreusable, Snare Size 25 Mm, Oval, Working Length 150 Cm, Foruse With Polypectomy Snare And Working Channelsas Of Size 2.8 Mm 158 Spare Snare,Should Be Strictly Usfda Aproovedreusable, Snare Size 15 Mm, Oval, Working Length 150 Cm, Foruse With Polypectomy Snare And Working Channelsas Of Size 2.8 Mm 159 Spare Tube,Should Be Strictly Usfda Aproovedreusable, For Oval Snares, Diameter 2.3 Mm, Working Length150 Cm 160 Spare Snare,Should Be Strictly Usfda Aproovedreusable, Snare Size 25 Mm, Oval, Working Length 250 Cm, Foruse With Polypectomy Snare And Working Channelsas Of Size 2.8 Mm161 Spare Snare,Should Be Strictly Usfda Aproovedreusable, Snare Size 15 Mm, Oval, Working Length 250 Cm, Foruse With Polypectomy Snare And Working Channelsas Of Size 2.8 Mm 162 Spare Tube,Should Be Strictly Usfda Aproovedreusable, For Oval Snares, Diameter 2.3 Mm, Working Length250 Cm 163 Handle,Should Be Strictly Usfda Aproovedonly, Reusable 164 Adaptor,Should Be Strictly Usfda Aproovedconnects Tube With Handle 165 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 35 Mm, Oval, Diameter 2.4 Mm, Working Length 160 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 166 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 30 Mm, Oval, Diameter 2.4 Mm, Working Length 160 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 167 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 30 Mm, Hexagonal, Diameter 2.4 Mm, Working Length 160Cm, For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 168 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 35 Mm, Oval, Diameter 2.4 Mm, Working Length 200 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated,169 Reusable, Snaresize 30 Mm, Oval, Diameter 2.4 Mm, Working Length 200 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 170 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 30 Mm, Hexagonal, Diameter 2.4 Mm, Working Length 200Cm, For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 171 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 30 Mm, Oval, Diameter 2.4 Mm, Working Length 120 Cm,For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 172 Polypectomy Snare,Should Be Strictly Usfda Aproovedcomplete, With Handle , Insulated, Reusable, Snaresize 30 Mm, Hexagonal, Diameter 2.4 Mm, Working Length 120Cm, For Use With High Frequency Surgery Units, For Use Withworking Channels As Of Size 2.8 Mm 173 Foreign Body Basket,Should Be Strictly Usfda Aproovedcomplete, With Handle , Reusable, Basket With 4Monofilament Cutting Wires, Diameter 2.2 Mm, Working Length120 Cm, For Use With Working Channels As Of Size 2.8 Mm 174 Spare Foreign Body Basket,Should Be Strictly Usfda Aproovedreusable, Working Length 120 Cm, For Use With Foreign Bodybasket And With Working Channels As Of Size 2.8Mm 175 Spare Tube,Should Be Strictly Usfda Aproovedreusable, Diameter 2.2 Mm, Working Length 120 Cm, For Usewith Foreign Body Basket And Working Channels Asof Size 2.8 Mm 176 Foreign Body Basket,Should Be Strictly Usfda Aproovedcomplete, With Handle , Reusable, Basket With 4Monofilament Cutting Wires, Diameter 2.2 Mm, Working Length160 Cm, For Use With Working Channels As Of Size 2.8 Mm 177 Spare Foreign Body Basket,Should Be Strictly Usfda Aproovedreusable, Working Length 160 Cm, For Use With Foreign Bodybasket And With Working Channels As Of Size 2.8Mm 178 Spare Tube,Should Be Strictly Usfda Aproovedreusable, Diameter 2.2 Mm, Working Length 160 Cm, For Usewith Foreign Body Basket And Working Channelsas Of Size 2.8 Mm 179 Foreign Body Basket,Should Be Strictly Usfda Aproovedcomplete, With Handle , Reusable, Basket With 4Monofilament Cutting Wires, Diameter 2.2 Mm, Working Length200 Cm, For Use With Working Channels As Of Size 2.8 Mm 180 Spare Foreign Body Basket,Should Be Strictly Usfda Aproovedreusable, Working Length 200 Cm, For Use With Foreign Bodybasket And With Working Channels As Of Size 2.8Mm 181 Spare Tube,Should Be Strictly Usfda Aproovedreusable, Diameter 2.2 Mm, Working Length 200 Cm, For Usewith Foreign Body Basket And Working Channels Asof Size 2.8 Mm 182 Papillotome,Should Be Strictly Usfda Aproovedsphincterotome, Filiform, Reusable, Complete, With Handle, Incision Length 40 Mm, Diameter 2.1 Mm, Workinglength 200 Cm, For Use With High Frequency Surgery Units, Foruse With Working Channels As Of Size 2.8 Mm 183 Papillotome,Should Be Strictly Usfda Aproovedsphincterotome, Filiform, Reusable, Complete, With Handle, Incision Length 30 Mm, Diameter 2.1 Mm, Workinglength 200 Cm, For Use With High Frequency Surgery Units, Foruse With Working Channels As Of Size 2.8 Mm 184 Papillotome,Should Be Strictly Usfda Aproovedsphincterotome, Standard, Reusable, Complete, With Handle, Incision Length 20 Mm, Diameter 2.1 Mm, Workinglength 200 Cm, For Use With High Frequency Surgery Units, Foruse With Working Channels As Of 2.8 Mm 185 Papillotome,Should Be Strictly Usfda Aproovedsphincterotome, Precut, Reusable, Complete, With Handle, Incision Length 30 Mm, Diameter 2.1 Mm, Workinglength 200 Cm, For Use With High Frequency Surgery Units, Foruse With Working Channels As Of Size 2.8 Mm 186 Papillotome,Should Be Strictly Usfda Aproovedsphincterotome, Precut, Reusable, Complete, With Handle, Incision Length 20 Mm, Diameter 2.1 Mm, Workinglength 200 Cm, For Use With High Frequency Surgery Units, Foruse With Working Channels As Of Size 2.8 Mm 187 Demling-Classen-Seuberth Papillotome Blade,Should Be Strictly Usfda Aproovedreusable, With Handle , Diameter 1.7 Mm, Length 200Cm, With Spare Snare, Spare Outer Tube 188 Outer Tube,Should Be Strictly Usfda Aproovedwith Snare, Length 200 Cm 189 Handle,Should Be Strictly Usfda Aproovedonly, Reusable, For Use With Papillotome Blade 13777 Aa 190 Handle,Should Be Strictly Usfda Aproovedonly, Reusable 191 Spare Snare With Tubing,Should Be Strictly Usfda Aproovedreusable, Ø 2.1 Mm, Working Length 200 Cm, Filiform, Incisionlength 40 Mm, For Use With Handle For Papillotome 192 Spare Papillotome With Tubing,Should Be Strictly Usfda Aproovedreusable, Filiform, Incision Length 30 Mm, Diameter 2.1 Mm,Working Length 200 Cm, For Use With Handle Forpapillotome 193 Spare Snare With Tubing,Should Be Strictly Usfda Aproovedreusable, Diameter 2.1 Mm, Working Length 200 Cm, Standard,Incision Length 20 Mm, For Use With Handle 13773 K Forpapillotome 194 Spare Papillotome With Tubing,Should Be Strictly Usfda Aproovedreusable, Precut, Incision Length 30 Mm, Diameter 2.1 Mm,Working Length 200 Cm, For Use With Handle 13773 K195 Spare Papillotome With Tubing,Should Be Strictly Usfda Aproovedreusable, Precut, Incision Length 20 Mm, Diameter 2.1 Mm,Working Length 200 Cm, For Use With Handle 13773 K Forpapillotome 196 Scissors,Should Be Strictly Usfda Aproovedflexible, Reusable, Diameter 2.2 Mm, Length 160 Cm 197 Scissors,Should Be Strictly Usfda Aproovedflexible, Reusable, Diameter 2.2 Mm, Length 200 Cm 198 Cytology Brush,Should Be Strictly Usfda Aproovedcomplete, Diameter 2.2 Mm, Working Length 120 Cm, For Usewith Working Channels As Of Size 2.8 Mm 199 Cytology Brush,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 120 Cm, For Use With Outertube, Adaptor , Handle Andworking Channels As Of Size 2.8 Mm 200 Cytology Brush,Should Be Strictly Usfda Aproovedcomplete, Diameter 2.2 Mm, Working Length 160 Cm, For Usewith Working Channels As Of Size 2.8 Mm201 Cytology Brush,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 160 Cm, For Use With Outertube, Adaptor , Handle Andworking Channels As Of Size 2.8 Mm 202 Outer Tube,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 120 Cm, For Use With Brush, Adaptor , And Workingchannels As Of Size 2.8 Mm 203 Outer Tube,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 160 Cm, For Use With Brush, Adaptor , Handle And Workingchannels As Of Size 2.8 Mm 204 Cytology Brush,Should Be Strictly Usfda Aproovedcomplete, Diameter 2.2 Mm, Working Length 200 Cm, For Usewith Working Channels As Of Size 2.8 Mm 205 Cytology Brush,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 200 Cm, For Use With Outertube , Adaptor , Handle Andworking Channels As Of Size 2.8 Mm 206 Outer Tube,Should Be Strictly Usfda Aproovedpackage Of 10, Working Length 200 Cm, For Use With Brush, Adaptor , Handle And Workingchannels As Of Size 2.8 Mm 207 Adaptor,Should Be Strictly Usfda Aproovedfor Suction Catheter 208 Handle,Should Be Strictly Usfda Aproovedfor Brush 209 Coagulation Electrode,Should Be Strictly Usfda Aproovedunipolar, Diameter 1.8 Mm, Working Length 120 Cm, For Usewith High Frequency Surgery Units, For Use With Workingchannels As Of Size 2.8 Mm 210 Coagulation Electrode,Should Be Strictly Usfda Aproovedbipolar, Diameter 2.2 Mm, Working Length 120 Cm, For Use Withhigh Frequency Surgery Units, For Use With Working Channelsas Of Size 2.8 Mm 211 Coagulation Electrode,Should Be Strictly Usfda Aproovedunipolar, Diameter 1.8 Mm, Working Length 160 Cm, For Usewith Working Channels As Of Size 2.8 Mm And High Frequencysurgery Units 212 Coagulation Electrode,Should Be Strictly Usfda Aproovedbipolar, Diameter 2.2 Mm, Working Length 160 Cm, For Use Withhigh Frequency Surgery Units, For Use With Working Channelsas Of Size 2.8 Mm 213 Coagulation Electrode,Should Be Strictly Usfda Aproovedunipolar, Diameter 1.8 Mm, Working Length 200 Cm, For Usewith High Frequency Surgery Units, For Use With Workingchannels As Of Size 2.8 Mm 214 Coagulation Electrode,Should Be Strictly Usfda Aproovedbipolar, Diameter 2.2 Mm, Working Length 200 Cm, For Use Withhigh Frequency Surgery Units, For Use With Working Channelsas Of Size 2.8 Mm 215 Biopsy Forceps,Should Be Strictly Usfda Aproovedfor Single Use, With Oval Jaws And Spike, Diameter 2.3 Mm,Working Length 200 Cm, Package Of 10, Sterile, For Use Withworking Channels As Of Size 2.8 Mm 216 Biopsy Forceps,Should Be Strictly Usfda Aproovedfor Single Use, With Oval Jaws And Spike, Diameter 2.3 Mm,Working Length 200 Cm, Package Of 10, Sterile, For Use Withworking Channels As Of Size 2.8 Mm 217 Biopsy Forceps,Should Be Strictly Usfda Aproovedfor Single Use, With Oval Jaws, Diameter 2.3 Mm, Workinglength 200 Cm, Package Of 10, Sterile, For Use With Workingchannels As Of Size 2.8 Mm 218 Biopsy Forceps,Should Be Strictly Usfda Aproovedfor Single Use, With Oval Jaws, Diameter 2.3 Mm, Workinglength 200 Cm, Package Of 10, Sterile, For Use With Workingchannels As Of Size 2.8 Mm 219 Biopsy Forceps,Should Be Strictly Usfda Aproovedfor Single Use, With Oval Jaws And Spike, Diameter 1.7 Mm,Working Length 200 Cm, Package Of 10, Sterile, For Use Withworking Channels As Of Size 2 Mm220 Single-Use Papillotome,Should Be Strictly Usfda Aproovedfiliform, Sterile, Package Of 5, Complete, With Handle, Incisionlength 25 Mm, Working Length 200 Cm, For Use With Highfrequency Surgical Units, For Use With Working Channels As Ofsize 2.2 Mm 221 Single-Use Papillotome,Should Be Strictly Usfda Aproovedfiliform, Sterile, Package Of 5, Complete, With Handle, Incisionlength 25 Mm, Guide Wire 4000 Mm, Working Length 200 Cm,For Use With High Frequency Surgical Units, For Use Withworking Channels As Of Size 2.8 Mm 222 Spray Catheter,Should Be Strictly Usfda Aproovedaxial, For Single Use, Length 180 Cm, For Working Channels Asof Diameter 2.2 Mm 223 Clickline Metal Outer Sheath, Insulated,Should Be Strictly Usfda Aproovedwith Luer-Lock Connector For Cleaning, Size 5 Mm, Length 36Cm 224 Clickline Metal Outer Sheath, Insulated,Should Be Strictly Usfda Aproovedwithout Luerlock Connector, Size 5 Mm, Length 36 Cm33400 2 Clickline Metal Outer Sheath, Insulated,With Luer-Lock Connector For Cleaning, Size 5 Mm, Length 43 Cm 225 Clickline Metal Outer Sheath, Insulated,Should Be Strictly Usfda Aproovedwithout Luerlock Connector, Size 5 Mm, Length 43 Cm 226 Clickline Metal Outer Sheath,Should Be Strictly Usfda Aprooved With Luer-Lock Connector For Cleaning, Size 5 Mm, Length 36 Cm 227 Clickline Metal Outer Sheath,Should Be Strictly Usfda Aproovedwithout Luer-Lock Connector, Size 5 Mm, Length 36 Cm 228 Clickline Metal Outer Sheath,Should Be Strictly Usfda Aproovedwith Luer-Lock Connector For Cleaning, Size 5 Mm, Length 43 Cm 229 Clickline Metal Outer Sheath,Should Be Strictly Usfda Aproovedwithout Luer-Lock Connector, Size 5 Mm, Length 43 Cm 230 Clickline Micro Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Dismantling, Single Action Jaws, Small Jaws, Size 5Mm, Length 43 Cm, With Luer-Lock Irrigation Connector Forcleaning,Consisting Of: Metal Handle, Without Ratchetouter Sheath, Insulatedforceps Insert 231 Clickline Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, With Luer-Lock Connector For Cleaning, Single Actionjaws, Medium Jaws, Standard Model For Mucosa Biopsy, Size5 Mm, Length 36 Cm,Consisting Of:Metal Handle, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 232 Clickline Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Insulated, With Connector Pin For Unipolarcoagulation, With Luer-Lock Irrigation Connector Forcleaning, Single Action Jaws, Medium Jaws, Standard Modelfor Mucosa Biopsy, Size 5 Mm, Length 43 Cm,Consisting Of:Plastic Handle, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 233 Clickline Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Insulated, With Connector Pin For Unipolarcoagulation, With Luer-Lock Connector For Cleaning, Singleaction Jaws, Medium Jaws, Standard Model For Mucosabiopsy, Size 5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Insulated, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 234 Clickline Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, With Luer-Lock Connector For Cleaning, Single Actionjaws, Medium Jaws, Standard Model For Mucosa Biopsy, Size5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Without Ratchetmetal Outer Sheath, Insulatedworking Insert, For Biopsy Forceps 235 Clickline Manhes Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Insulated, With Connector Pin For Unipolarcoagulation, With Irrigation Connection For Cleaning, Largejaws, Single Action Jaws, Size 5 Mm, Length 36 Cm,Consisting Of:Plastic Handle, Without Ratchetouter Sheath, Insulatedforceps Insert 236 Clickline Manhes Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Insulated, With Connector Pin For Unipolarcoagulation, With Irrigation Connection For Cleaning, Singleaction Jaws, Large Jaws, Size 5 Mm, Length 36 Cm,Consisting Of:Metal Handle, Insulated, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 237 Clickline Manhes Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, Insulated, With Connector Pin For Unipolarcoagulation, With Irrigation Connection For Cleaning, Singleaction Jaws, Large Jaws, Size 5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Insulated, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 238 Clickline Manhes Biopsy Forceps,Should Be Strictly Usfda Aproovedrotating, With Irrigation Connection For Cleaning, Single Actionjaws, Large Jaws, Size 5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Without Ratchetmetal Outer Sheath, Insulatedforceps Insert 239 Clickline Biopsy Punch,Should Be Strictly Usfda Aproovedrotating, Dismantling, With Connector Pin For Unipolarcoagulation, With Luer-Lock Connector For Cleaning, Singleaction Jaws, Through-Cutting, Size 5 Mm, Length 36 Cm,Consisting Of:Plastic Handle, Insulated, Without Ratchetmetal Outer Sheath, Insulatedpunch Forceps Insert 240 Clickline Biopsy Punch,Should Be Strictly Usfda Aproovedrotating, Dismantling, With Connector Pin For Unipolarcoagulation, With Irrigation Connection For Cleaning, Singleaction Jaws, Through-Cutting, Size 5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Insulated, Without Ratchetmetal Outer Sheath, Insulatedpunch Forceps Insert241 Clickline Biopsy Punch,Should Be Strictly Usfda Aproovedrotating, Dismantling, Without Connector Pin For Unipolarcoagulation, With Irrigation Connection For Cleaning, Singleaction Jaws, Through-Cutting, Size 5 Mm, Length 43 Cm,Consisting Of:Metal Handle, Without Ratchetmetal Outer Sheath, Insulatedpunch Forceps Insert 242 Snare Guide,Should Be Strictly Usfda Aproovedinsulated, With Connector For Unipolar Coagulation, Workinglength 30 Cm 243 Snare Guide,Should Be Strictly Usfda Aproovedinsulated, With Connector For Unipolar Coagulation, Workinglength 40 Cm 244 Snare Guide,Should Be Strictly Usfda Aproovedinsulated, With Connector Pin For Unipolar Coagulation, Withself-Forming Wire Snare, Working Length 40 Cm 245 Polyp Grasping Forceps,Should Be Strictly Usfda Aproovedworking Length 40 Cm, For Use With Snare Guide 246 Wire Snare,Should Be Strictly Usfda Aproovedfor Snare Guides , Package Of 25 247 Wire Snare,Should Be Strictly Usfda Aproovedsingle, For Snare Guide 248 Wire Tray For Cleaning, Sterilization And Storage,Of E.G. Pecd-Endoscope 8163 Pcd, Including Cleaningadaptor For Washer-Disinfector, With Lid, Spare Parts Basket39501 Xs And Silicone Telescope Holders, Externaldimensions (W X D X H): 460 X 150 X 80 Mm, For Instrumentswith Up To 27 Cm Working Length 249 Clickline Reddick-Olsen Grasping Forceps,Should Be Strictly Usfda Aproovedrotating, Size 2 Mm, Length 30 Cm, With Connector Pin Forunipolar Coagulation, Double Action Jaws, With Irrigationconnection For Cleaning,Consisting Of:Plastic Handle, Without Ratchet Outer Sheath With Working Insert, Insulated 250 Clickline Plastic Handle,Should Be Strictly Usfda Aproovedrotating, Insulated, Without Ratchet, With Connector Pin Forunipolar Coagulation 251 Outer Sheath With Reddick-Olsen Working Insert,Should Be Strictly Usfda Aproovedinsulated, With Luer Lock Adaptor For Cleaning, Size 2 Mm 252 Scissors Insert And Outer Tube, Metzenbaum Scissors, Curved, Length Of Blades 12Mm Double Action Jaws, Size 5 Mm, Length 36Cm, Package Of 10, Sterile, Disposable 253 Scissors Insert With Outer Sheath, Curved, Double Action Jaws, Spoon-Shaped Jaws, Length Of Blades 17Mm Size 5Mm Length 36Mm, Sterile, For Single Use, Package Of 10

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail