Tender for Extension Of Control Room Building And Providing Structural Equipment Plinths, Cable Duct, Water Supply Line For Earth Pits, Metal Spreading, Earthfilling, Road And Other Allied Civil Works Etc., For The Enhancement Of Existing 110 / 11 Kv Power Transformer Capacity From 2X10 Mva To 3X10 Mva At Sathumadurai 110 / 11 Kv Substation
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for in hard gravelly soil |
| 2 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for In SDR (Not Requiring Blasting) |
| 3 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete for Medium rock and dense medium rock not requiring blasting |
| 4 | Earthwork excavation for foundation with an initial lead of 10 m and lift of 2 m etc complete by Removal of hard rock by wedging and chiselling and trimming to proper shape |
| 5 | Supplying and filling in foundation and basement with filling sand in layers not more than 15 cm thick well rammed and watered consolidated etc complete as per standard specification |
| 6 | Re - filling in foundation with excavated earth in layers not more than 15 cm thick well rammed and watered consolidated etc complete as per standard specification |
| 7 | Laying PCC 1:3:6 mix using 20 mm HBG machine crushed metal for foundation concrete including cost of all labour, materials, lead, lift, curing etc. Complete. |
| 8 | PCC 1:2:4 mix using 20 mm downgraded HBG machine crushed metal for foundation concrete without form work, cost of all labour, materials, lead, lift, curing etc. complete as per standard specification. |
| 9 | PCC 1:2:4 mix using 20 mm downgraded HBG machine crushed metal for plinth concrete including form work cost of all labour, materials, lead, lift, curing etc. complete as per standard specification. |
| 10 | R:C:C 1:1.5:3 using 12 to 20mm metal for cable duct bottom , road culvert bottom slab concrete with form work including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 11 | R:C:C 1:1.5:3 using 12 to 20mm metal for plinth concrete with form work including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site..but excluding cost of steel reinforcement |
| 12 | R:C:C 1:1.5:3 using 12 to 20 mm metal for footing concrete with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site .but excluding cost of steel reinforcement |
| 13 | R:C:C 1:1.5:3 using 12 to 20 mm metal for Grade beam concrete with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 14 | R:C:C 1:1.5:3 using 12 to 20 mm metal for Column upto basement concrete with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 15 | R:C:C 1:1.5:3 using 12 to 20 mm metal for Column above basement with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 16 | R:C:C 1:1.5:3 using 12 to 20 mm metal for precast slab for cable duct and other with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 17 | R:C:C 1:1.5:3 using 12 to 20 mm metal for Roof beam with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 18 | R:C:C 1:1.5:3 using 12 to 20 mm metal for Roof slab with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 19 | R:C:C 1:1.5:3 using 12 to 20 mm metal for lintel beam with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 20 | R:C:C 1:1.5:3 using 12 to 20 mm metal for sunshade and loft concrete with form work for reinforced concrete structural elements under controlled water cement ratio with plasticiser including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.but excluding cost of steel reinforcement |
| 21 | Supplying and fabricating and placing in position of MS/RTS steel reinforcement for RCC works including labour for cutting, bending, tying and fixing in position as per specification including cost of all materials, lead, lift, labour, cost of binding wire etc.complete. |
| 22 | Brick work in CM 1:5 using ll Class Ground Moulded Chamber Burnt bricks for foundation Basement wall ( ie, control room & cable duct etc.,) including the cost of all materilas , lead, lift, labour, Centering Charges T&P etc., complete as directed by the Engineers at site. |
| 23 | Brick work in CM 1:5 using ll Class Ground Moulded Chamber Burnt bricks for super structure ( ie, control room etc.,) including the cost of all materilas , lead, lift, labour, Centering Charges T & P etc., complete as directed by the Engineers at site. |
| 24 | Fabriaction, galvanising and supply of various dia & lenth of bolt for placing electrical equipment into plinth like 20 mm dia 1.2 m and other length and other dia of foundation bolt and nuts with 2 nos.washer in High Tensile Steel including 10 cm L at bottom and 15 cm threading with 2 nuts and washers at top including cost of all materials, labour, lead, lift etc. complete.as directed by the dept. Engineer at site |
| 25 | Fabrication of Template and assembling in correct position for various equipment plinth and grouting the foundation bolts including cost of all materials, labour, lead, lift etc. complete.as directed by the dept. Engineer at site |
| 26 | Providing, Transporting and fixing of 90 lbs rail in correct position and level as directed by dept.Engineer at site including cost of Rail, cutting charges, transport to site etc. complete. |
| 27 | Levelling the ups and downs of the location by engaging JCB for marking of foundations, etc., with all hire charges etc complete. |
| 28 | Transporting and fixing of RCC cover slab from curing tank to working spot including cost of labour, lead, lift etc., complete. |
| 29 | Supplying and fixing readymade earth collars of size 60 cm inner dia with 30 cm height and shell thickness of 50 mm including cost of all materials,transport to site , labour, lead, lift, etc., complete., as per standard specification. |
| 30 | Supplying and fixing of 20 mm PVC bib cock including cost of all materials, etc., complete. |
| 31 | Supplying, fabrication, galvanization and fixing MS angle, channel, MS rail, etc wherever required as directed by the Engineer as per standard specifcation |
| 32 | Supplying and spreading of stone dust including cost of materilas , labour all lead and lift etc. Complete. |
| 33 | Supplying and spreading of 20 mm B.G metal including cost of metal ,labour all lead and lift etc . Complete. |
| 34 | Plastering in cm 1:3 mix 12 mm thick for bottom of roof slab, bottom and sides of sunshade, loft, partition walls etc. including cost of all materials, lead, lift, watering, curing etc complete |
| 35 | Plastering with cm 1:5 mix using 12 mm thick for inside and outside walls, etc., including cost of all materials,labour,lead, lift etc complete |
| 36 | Providing projected border of 7.50cm width on top of parapet wall in CM 1:3 mix 12mm thick including cost of all material labour, lead, lift, curing etc., complete. |
| 37 | Writing the name of sub station and safety slogn on wall over plasterd surface using approved colour and quality enamel paint over a cost of primer including cost of all materials , lead,lift etc., complete |
| 38 | Supplying and fixing MS grill gates, MS grills, name board, hand rail, lader etc.at various levels as per approved drawing using channel, squar rods, ornamentel grill parts and flat including fixing in position with suitable hold fast locking arrangements, painting with one coat of primer and two coats of Enamel paints of approved colour etc.complete as per standard specification |
| 39 | Supplying and fixing in position of anodized Al. glazed sliding window of size 1.20 x 1.35 m as per ISS 1038-1958 (1245 ISS) using Al. sections window frame bottom two track sliding 61.85 x 31.75 x 1.50mm @ 0.909 Kg/m, top & side 61.85 x 31.75 x 1.50mm @ 0.784 Kg / m shutter plain out side 40 x 18 x 1.55mm @ 0.547 Kg /m shutter inner lock 40 x 18 x 1.45 mm @ 0.607 Kg /m shutter runner top & bottom 40 x 18 x 1.55mm @ 0.547 Kg / m with glazing clips rubber gaskets sliding wheel & 5.5mm tk sun cool glass including cost of all materials, lock arrangements labour, lead, lift, etc., complete. |
| 40 | Supplying and fixing of anodized aluminium fully glazed door using 101.60 x 44.45 x 2.10 mm box section for outer frame, 53.70 x 44.50x2.30mm @1.238kg/m box door vertical and top 83.50x44.45x2.4mm box section for bottom panels with 6mm clear glass including cost of alum clips rubber beedings alum fixtures such as tower bolt, pivot automatic hydroulic door closure brass mortice lock handle ok. Including cost of all materials, labour, leads, lift etc. complete. (1.20x2.40m size single leaf) |
| 41 | Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 42 | Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. for 40mm dia |
| 43 | Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. for 32 mm dia |
| 44 | Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. for 25 mm dia |
| 45 | Providing and laying PVC high density pipe (10 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. for 20 mm dia |
| 46 | Providing and fixing Gate valve of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site. For 40 mm dia |
| 47 | Providing and fixing Gate valve of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site. For 32 mm dia |
| 48 | Providing and fixing wheel valve of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site. For 32 mm dia |
| 49 | Providing and fixing wheel valve of Gun metal made including cost of all materials, labour, lead and lift etc., complete and as directed by the Engineer-in-charge at site. For 25 mm dia |
| 50 | White washing 2 coats using emulsion paint over one coat of primer with white colour for ceiling in all floors and exposed faces of beams,steps & sunshade including cost of all materials and scaffolding etc. complete. |
| 51 | Painting the inside walls and control room front face with two coats of best quality interior emulsion over primer one coat and two coats of wall putty of approved colour including cost of all materials and scaffolding etc. complete. |
| 52 | Painting out side walls and plinths with two coats of best quality exterior emulsion over primer one coat of approved colour including cost of all materials and scaffolding etc. complete. |
| 53 | Supply and run of 2 x 1.5 sq.mm (22/0.3) PVC insulated Multistrand unsheathed copper conductor of 1100 V gradein in PVC rigid pipe concealed in wall and ceiling with continuous earthwire connection of 1.5 sq.mm copper wire for making good of the concealed portion with suitable colour |
| 54 | Wiring with 2 x 1.5 sq.mm (22/0.3) PVC insulated SC unsheathed multistrand Copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with metal box with modular switches 5A/15A with continuous earthwire connection of 1.5 sq.mm copper wire for making good of the concealed portion with suitable colour for PVC concealed light point/fan point |
| 55 | Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated SC unsheathed Cu.conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall ,with 150x100x113mm with metal box with modular switches for 5 A 3 Pin non interlocking wall socket with 5A fluh type switch with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed PVC Plug point. |
| 56 | Wiring with 2 x 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor cable of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150 mm x 100 mm x 113 mm Steel with metal box with modular switches for 15 A 3 Pin non interlocking wall socket with 15A fluh type switch with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed power Plug point. |
| 57 | Supply and fixing of 32 A TPN MC switch on suitable angle iron frame work with MS cable entry box with earth connection only. |
| 58 | Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor of 1100 V Grade in suitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 59 | Supplying and fixing box type 4'-40 w single LED fitting 20w of approved brand on wall or ceiling with pvc unsheated leads from terminals to the fittings |
| 60 | Supply and fixing of 4' 40 W Twin Mirror optic suspension type fitting (Philips / Crompton / Wipro) complete with louvers cover complete with copper choke and condensor with conduit pipe suspension, with PVC unsheathed Copper leads from the terminals to the fittings with flu. tubes. |
| 61 | Supply and fixing of 1400 mm sweep (56\\") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450 mm. |
| 62 | Supplying and fixing of RCCB safe trip of appd LEGRAND, ISI make, 25amps with suitable box including cost of all materials labour, lead, lift, etc., complete as per standard specification. |
| 63 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make). |
| 64 | Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work. |
| 65 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 Amps per way with 63 A TPN MC switch with suitable trunking box MS cable entry and internal connection in suitable angle iron frame work, with earth connections. |
| 66 | Filling with good quality gravel including cost of material, labour all lead and lift for 110 KV, 33 KV Yard, control room inside and road portion aetc . Complete. |
| 67 | Releasing the existing windows and doors at Sathumadurai 110 KV SS with an initial lead,lift etc., complete. |
| 68 | Dismantling of existing brick masonry wall at Sathumadurai 110 KV SS with an initial lead,lift etc., complete. |
| 69 | Dismantling of existing RCC pillar wall & RCC Roof slab at Sathumadurai 110 KV SS with an initial lead,lift etc., complete. |
| 70 | Dismantling of existing RR masonry at Sathumadurai 110 KV SS with an initial lead,lift etc., complete. |
| 71 | Providing and laying PVC high density pipe (4 kg. per cm2 ) including cost of all specials like coupling, bend etc., and including necessary earthwork and burrying , all material labour, etc., complete and as directed by the Engineer-in-charge at site.. For 110 mm dia |
| 72 | GST for bidders within Tamil Nadu |
| 73 | GST for bidders outside Tamil Nadu (IGST) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender