Tender For Schemes Pertaining To The Health & Family Welfare, Department, Gta For The Annual Action 2026-27 (Sp Funds) Package-Iii
Tender Value
92.23 Lakhs
Estimated cost
Bid Submission
18 Dec 2026
19 days left
EMD
1.84 Lakhs
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Schemes Pertaining To The Health & Family Welfare, Department, Gta For The Annual Action 2026-27 (Sp Funds) Package-Iii
BOQ
| Sl. No. | Item Description |
| 1 | Estimate for Supplying and Installation of Solar Street Lights at Sonada PHC, GTA |
| 2 | Supplying, installation, Testing & Commissioning ofthe integrated type solar PV lighting system on theexisting pole structure, comprising of 30 watt, 6VMono Passivated Emitter and Rear Contact (PERC)Solar Panel (minimum efficiency 21%), Pulse withmodulation (PWM)/Maximum Power point tracking(MPPT) charge Controller in the box with a sleekappearance and a sturdy structure, is weather-proof,and is simple to install, With Lithium- IronPhosphate Battery (LiFePO4), charging time 8-10hours, Battery backup time 12 hours (minimum),LED fixture watt 30 watt, Input voltage: 12V DC ,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%, IP-66,IK-08, CRI >70 , undervoltage and over voltage protection, ElectroMagnetic Interference (EMI) Electro MagneticCompatibility (EMC) As per CISPER 15 A, lensesfor beam angle as per Illuminating EngineeringSociety of North America (IESNA) type I/II/III as perthe width of the road and the project requirement,Correlated Colour Temperature (CCT) 5700°K (Asper American National Standard Institute (ANSI................................TM-21-11 report, automatic swich on/off,Alliuminium or Acrylonitrile Butadiene Styrene (ABSbody), can be installed on a pole or wall. Systemlumen efficacy >120 lm/Watt output. LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. All as perpre approved by Engineer in-charge complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor singlecore cable and earthing etc. as required,complete with mounting structure for the battery andaccessories suitable for withstand wind stormspeed as per the site location. (Thermalmanagement: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C). 30 Watt (System lumen efficacy >120 lm/Watt) |
| 3 | Supply of 7 mts G.I. Octagonal Poles Top-70 mm, Bottom- 130 mm, thickness-3mm with base plate-220x220x12mm and foundation bolt M20x700mmx 4 Nos. and single arm bracket 1 mtr. Submission of test reports and warranty certificates for atleast 5 yrs from OEM is mandatory. |
| 4 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 5 | Above 6.5 Meter and upto 8.0 Meter |
| 6 | Temporary Site Facilities and Maintenance |
| 7 | Estimate for Supplying and Installation of Solar Street Lights at Ghoom PHC, GTA |
| 8 | Supplying, installation, Testing & Commissioning ofthe integrated type solar PV lighting system on theexisting pole structure, comprising of 30 watt, 6VMono Passivated Emitter and Rear Contact (PERC)Solar Panel (minimum efficiency 21%), Pulse withmodulation (PWM)/Maximum Power point tracking(MPPT) charge Controller in the box with a sleekappearance and a sturdy structure, is weather-proof,and is simple to install, With Lithium- IronPhosphate Battery (LiFePO4), charging time 8-10hours, Battery backup time 12 hours (minimum),LED fixture watt 30 watt, Input voltage: 12V DC ,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%, IP-66,IK-08, CRI >70 , undervoltage and over voltage protection, ElectroMagnetic Interference (EMI) Electro MagneticCompatibility (EMC) As per CISPER 15 A, lensesfor beam angle as per Illuminating EngineeringSociety of North America (IESNA) type I/II/III as perthe width of the road and the project requirement,Correlated Colour Temperature (CCT) 5700°K (Asper American National Standard Institute (ANSI................................TM-21-11 report, automatic swich on/off,Alliuminium or Acrylonitrile Butadiene Styrene (ABSbody), can be installed on a pole or wall. Systemlumen efficacy >120 lm/Watt output. LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. All as perpre approved by Engineer in-charge complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor singlecore cable and earthing etc. as required,complete with mounting structure for the battery andaccessories suitable for withstand wind stormspeed as per the site location. (Thermalmanagement: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C). 30 Watt (System lumen efficacy >120 lm/Watt) |
| 9 | Supply of 7 mts G.I. Octagonal Poles Top-70 mm, Bottom- 130 mm, thickness-3mm with base plate-220x220x12mm and foundation bolt M20x700mmx 4 Nos. and single arm bracket 1 mtr. Submission of test reports and warranty certificates for atleast 5 yrs from OEM is mandatory. |
| 10 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 11 | Above 6.5 Meter and upto 8.0 Meter |
| 12 | Temporary Site Facilities and Maintenance |
| 13 | Estimate for Supplying and Installation of Solar Street Lights at Pokhriabong PHC, GTA |
| 14 | Supplying, installation, Testing & Commissioning ofthe integrated type solar PV lighting system on theexisting pole structure, comprising of 30 watt, 6VMono Passivated Emitter and Rear Contact (PERC)Solar Panel (minimum efficiency 21%), Pulse withmodulation (PWM)/Maximum Power point tracking(MPPT) charge Controller in the box with a sleekappearance and a sturdy structure, is weather-proof,and is simple to install, With Lithium- IronPhosphate Battery (LiFePO4), charging time 8-10hours, Battery backup time 12 hours (minimum),LED fixture watt 30 watt, Input voltage: 12V DC ,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%, IP-66,IK-08, CRI >70 , undervoltage and over voltage protection, ElectroMagnetic Interference (EMI) Electro MagneticCompatibility (EMC) As per CISPER 15 A, lensesfor beam angle as per Illuminating EngineeringSociety of North America (IESNA) type I/II/III as perthe width of the road and the project requirement,Correlated Colour Temperature (CCT) 5700°K (Asper American National Standard Institute (ANSI................................TM-21-11 report, automatic swich on/off,Alliuminium or Acrylonitrile Butadiene Styrene (ABSbody), can be installed on a pole or wall. Systemlumen efficacy >120 lm/Watt output. LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. All as perpre approved by Engineer in-charge complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor singlecore cable and earthing etc. as required,complete with mounting structure for the battery andaccessories suitable for withstand wind stormspeed as per the site location. (Thermalmanagement: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C). 30 Watt (System lumen efficacy >120 lm/Watt) |
| 15 | Supply of 7 mts G.I. Octagonal Poles Top-70 mm, Bottom- 130 mm, thickness-3mm with base plate-220x220x12mm and foundation bolt M20x700mmx 4 Nos. and single arm bracket 1 mtr. Submission of test reports and warranty certificates for atleast 5 yrs from OEM is mandatory. |
| 16 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 17 | Above 6.5 Meter and upto 8.0 Meter |
| 18 | Temporary Site Facilities and Maintenance |
| 19 | Supplying, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant for 13 nos. HWCs and 2 nos. SCs under Sukhia Jorebunglow Block , GTA (Electrical) |
| 20 | Supplying, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant for 13 nos. HWCs and 2 nos. SCs of 2KVA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender