Tender For Development Of Road From Satnala To Manuchailengta Adc Village Road Under Dasda R.D. Block (Length - 1.00 Km )/ Sh: Wbm-Ii, Inter Locking Paver Block, Reinforced Cement Concrete Drain & Toe Wall Etc From Ch. 0.00Km To Ch. 0.450Km.
Tender Overview
Project Description
Tender for Development Of Road From Satnala To Manuchailengta Adc Village Road Under Dasda R.D. Block (Length - 1.00 Km )/ Sh: Wbm-Ii, Inter Locking Paver Block, Reinforced Cement Concrete Drain & Toe Wall Etc From Ch. 0.00Km To Ch. 0.450Km.
BOQ
| Sl. No. | Item Description |
| 1 | PROTECTION WORK Excavation for Structures(A) Without dewatering.Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.I. Ordinary Soil(i) Upto 3 m depth |
| 2 | Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200.(I) Sand filling |
| 3 | Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement)I. P.C.C grade M 10 ( Using Jhama Brick Aggregate )(i) Nominal mix 1:3:6 |
| 4 | Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement)II. P.C.C grade M 15 ( Using Jhama Brick Aggregate )(I) Nominal mix 1:2.5:5 |
| 5 | Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7. |
| 6 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202. |
| 7 | GRANULAR SUB - BASES, (Non -Bituminous) Granular Sub-base with Well Graded Material (Table 400.1 ) using Jhama Brick Aggregate(A) By Mix in Place MethodConstruction of granular sub-base by providing well graded material ( Jhama Brick Aggregate , Grading-I as per Table 400.1, spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401.(i)For Grading I Material (jhama brick aggregate) |
| 8 | WBM Grading 3Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 3 as per MoRD Technical Specification Clause 405.(A) By Manual Means |
| 9 | 80 mm thick factory made c.c. interlocking paver block of M-35 GradeProviding and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge:(A) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern. |
| 10 | RCC Cover DrainExcavation for Structures(A) Without dewatering.Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.I. Ordinary Soil(i) Upto 3 m depth |
| 11 | Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200.(I) Sand filling |
| 12 | Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement)I. P.C.C grade M 10 ( Using Jhama Brick Aggregate )(i) Nominal mix 1 : 3 : 6 |
| 13 | Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement)(VI RCC grade M25 Upto 5m height |
| 14 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202. |
| 15 | Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8. |
| 16 | Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender