Tender For Construction Of Shelter For Building And Other Construction Workers (Bocw) At Labour Chowk, Bathubasthi Under E&M Division, Apwd, Prothrapur.Sw: Providing Iei And Eei.
Tender Value
7.37 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
4 days left
EMD
14755
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Shelter For Building And Other Construction Workers (Bocw) At Labour Chowk, Bathubasthi Under E&M Division, Apwd, Prothrapur.Sw: Providing Iei And Eei.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group - C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | c) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | Supplying and fixing of 4 o/g bus chamber on surface/recess complete with copper bus bar, interconnections etc as required. (Make: Indoasian, Code : CPPI1016 or its equivalent). |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 8 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).a) 4 way (4 + 12), Double Door |
| 9 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 A |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single Pole |
| 11 | Supplying and fixing of square type surface/recess CRCA housing 32 W LED 6500K similar to Phillips code SM366C LED32-6500 PSU OD WH or its equivalent complete with all accessories including connections etc. as required in false ceiling. |
| 12 | Supplying of BLDC Ceiling Fan 1200mm Sweep (Colour: White/Brown) similar to Crompton ENERGION Riviera, 5 Star & ISI without remote or its equivalent. |
| 13 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 14 | Supplying and fixing stepped modular type electronic fan regulator on the existing switch box including connections, etc. as required. (Make : Anchor, Code : 8414 or its equivalent). |
| 15 | Supplying and fixing of Street Light luminares 25 Wattage Make : Guardian Street light or its equivalent, with IP66 housing protection i/c clamping arrangement with GI Pipe of 1 metre length ( including bending pipe)etc., as required |
| 16 | Supplying of following XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS: No. 7098 (Part-I) and IS: No. 1554 (Part-I) 1958 as applicable. Make:- Havells or its equivalent.a) 25 Sq.mm x 3.5 Core |
| 17 | Supplying and laying of double walled corrugated high density polythlene pipe having corrugated on the outer wall and plain surface inner wall confirming to IS: 14930 part-I & II complete with necessary accessories like socket, bend, coupler, etc for protection of 1.1 KV grade under ground/concrete cutting at depth of 50cm i/c excavation and refilling the trench as required.a) 50 x 38 mm ( O/D X I/D) |
| 18 | Supplying and laying of double walled corrugated high density polythlene pipe having corrugated on the outer wall and plain surface inner wall confirming to IS: 14930 part-I complete with necessary HDPE fitting for protection of 1.1 KV grade underground cable directly on the surface or wall etc as reqd.a) 50 x 38 mm ( O/D X I/D) |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.a) Upto 35 sq. mm |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall /surface as required. |
| 21 | Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2000mm, dia 50 mm, Type- 19 and inner space be filled with crystalline conductive mixture including filling-up with electrodite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok) |
| 22 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 23 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender