Housing Urban and Rular Development Government Departments Closing in 7 days TDR #58759373

Tender For Widening And Strengthening Work Of Atamanda To Dhora Shahi Mirzapur Via Balliya Sheeshgarh (Odr) (Length 12.000 Km) In District Bareilly For District Bareilly Fy 2026-27 (Including Maintenance For 05 Year) .Drain- 1.680 Kmretaining Wall- 1

Issued by Government Departments · Bareilly, Uttar Pradesh
Tender Value
18.88 Crore
Estimated cost
Bid Submission
04 Dec 2026
7 days left
EMD
30 Lakhs
Bank guarantee accepted
Document Fee
2725
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Widening And Strengthening Work Of Atamanda To Dhora Shahi Mirzapur Via Balliya Sheeshgarh (Odr) (Length 12.000 Km) In District Bareilly For District Bareilly Fy 2026-27 (Including Maintenance For 05 Year) .Drain- 1.680 Kmretaining Wall- 160 Mtrbox Culvert- 3Mtr Span

BOQ

Name of Work:- Widening and strengthening work of Atamanda to Dhora Shahi Mirzapur via Balliya Sheeshgarh (ODR) (length 12.000 km) in district Bareilly for District Bareilly FY 2026-27 (Including Maintenance for 05 year) .Drain- 1.680 KmRetaining wall- 160 mtrBox Culvert- 3mtr Span
Sl. No. Item Description
1Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
2Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
3Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2. (For Compaction of earth)
4Construction of granular sub-base by providing close graded material mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with Mechanical Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
5Scarifying the existing granular road surface to a depth of 50 mm and disposal of scarified material within all lifts and leads upto 1000 metres.
6Providing, laying, spreading and compacting graded stone aggregate mixed with cement to crushed stone treated base specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
7Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
8Providing and laying priming coat with bitumen emulsion (SS-2 grade) using Emulsion pressure distributor at the rate of 0.60 Kg. Per sqm on the prepared surface of granular base cleaned with mechanical broom.
9Providing and applying tack coat with bitumen using VG-10 pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
10Providing and laying bituminious concrete with 100-120 batch type HMP producing an average output of 75 tonne per hour using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.40% as per job mix, and filler, transporting the hot mix to work site,laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT & H Specifications Clause 509 complete in all respects.
11Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
12Providing and laying of factory made 80 mm thick Interlocking cement concrete tiles (30mpa) including 25mm thick compacted bed of fine sand compacting and proper embedding/ laying of Interlocking tiles leveling and dressing of surface to required level and slope, filling joints with fine sand including the cost of material, labour T&P etc.required for proper completion of work as directed by Engineer-in-Charge. (SI No New Item. 1)
13Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
14Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
15Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
16Sand filling in foundation trenches as per Drawing & technical specification no 304
17Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.(Grade M-30)
18Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.
19Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
20Drainage Spouts complete as per drawing and Technical specification
21Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.
22Dewatering of ground water for trenches with hire charges operational & fule charges of pump with oprator etc.. Complete as per direction of E/i.
23Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
24Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications (MOR&H Specification no 2504)
25Providing and laying stone boulder pitching using 25-60 kg stone boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and technical specifications .
26Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications.
27M-20 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and as per MORT&H Specification Clause 1500, 1700 & 2100.
28Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical Specifications
29Providing and laying reinforced cement concrete pipe NP3 1000 mm dia for culverts on first class bedding of granular material in Single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry
30Pointing with cement mortar (1:3 ) on brick work in substructure as per Technical Specifications Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58759373
AUTHORITY Government Departments
TENDER VALUE 18.88 Crore
LAST DATE 04-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Widening And Strengthening Work Of Atamanda To Dhora Shahi Mirzapur Via Balliya Sheeshgarh (Odr) (Length 12.000 Km) In District Bareilly For District Bareilly Fy 2026-27 (Including Maintenance For 05 Year) .Drain- 1.680 Kmretaining Wall- 160 Mtrbox Culvert- 3Mtr Span
Basic Detail
Tender No 10168/413C(E-Tender)-3/2026-27 Dated 07.11.2026
Bidding Type Tender
Location
City Bareilly
State Uttar Pradesh
Key Dates
Publish Date 27 Nov 2026
Submission Date 04 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value 18.88 Crore
Tender Fee 2725
EMD 30 Lakhs
Exemption Available
Document List
17b71c7a-8425-477e-97b8-86b1ca406f91.html
Addendum.pdf
BOQ_2308019.xls
PartBSBD.pdf
RetenderSBD.pdf
SBDPart1.pdf
SBDPart2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 27, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

17b71c7a-8425-477e-97b8-86b1ca406f91.html

pdf

Addendum.pdf

xls

BOQ_2308019.xls

pdf

PartBSBD.pdf

pdf

RetenderSBD.pdf

pdf

SBDPart1.pdf

pdf

SBDPart2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender