Tender For Internal Electrification Of 02 No Barracks And Cafeteria At Newly Proposed Livelihood Hub Near Kanchanpur Revenue Dak Bunglow Under R.D. Kanchanpur Sub Division During The Year 2026-27.
Tender Value
6.34 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
5 days left
EMD
12695
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal Electrification Of 02 No Barracks And Cafeteria At Newly Proposed Livelihood Hub Near Kanchanpur Revenue Dak Bunglow Under R.D. Kanchanpur Sub Division During The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing of 3 pin 5/6 amps plug point with fancy type 5/6 amps switch and socket with cover plate including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthing the 3rd pin etc. as required:- |
| 2 | Providing and fixing of 3/6 pin 15/16 amps plug point with fancy type 15/16 amps switch and socket with cover plate including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthing the 3rd pin etc. as required;- |
| 3 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) complete with pvc switch board and fancy type switch with cover plate including connection etc as required.Short Point :- |
| 4 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) complete with pvc switch board and fancy type switch with cover plate including connection etc as required.Medium Point :- |
| 5 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) complete with pvc switch board and fancy type switch with cover plate including connection etc as required.Long Point :- |
| 6 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- 2 X 1.5 sq mm |
| 7 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:-2 X 2.5 sq mm |
| 8 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:-4 X 4 sq mm |
| 9 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- 4 X 10 sq mm |
| 10 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-1 X 1.5 sq mm |
| 11 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 2.5 sq mm |
| 12 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.25 mm dia |
| 13 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.32 amps one way DP switch (2M):- |
| 14 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.20/25 amps single phase motor starter switch (2M):- |
| 15 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 16 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 17 | Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 18 | Supply and fixing of the following sizes GI prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection. Copper. Prong 1000 mm long |
| 19 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 20 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 21 | Supplying & installation of 400 mm sweep AC padestal fan with plastic blade including connection etc as required:- |
| 22 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 23 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 24 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 25 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 26 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 27 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-25 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 28 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 29 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 30 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 31 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):- |
| 32 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330mmx280mmx100mm):- |
| 33 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-32 amps 240 volts DP main switch (rewireable):- |
| 34 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-63 amps 415 volts TPN main switch (rewireable):- |
| 35 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(2+6) / 8 way SPN MCB DB (double door):- |
| 36 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(2+10) / 12 way SPN MCB DB (double door):- |
| 37 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.6 way horizontal TPN MCB DB (Double door):- |
| 38 | Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:-Enclosure suitable for MCCB upto 100 amps:- |
| 39 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-6 to 32 amps SP MCB:- |
| 40 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-40 amps DP isolator:- |
| 41 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-63 amps FP isolator:- |
| 42 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 43 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required3 core 4 Sq mm |
| 44 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required 4 core 4 Sq mm |
| 45 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required 4 core 6 Sq mm |
| 46 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required.3 core 2.5 Sq mm |
| 47 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required.3 core 4 Sq mm |
| 48 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -1.5 sqmm - 4 sqmm Cable:- |
| 49 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: -10 sq mm |
| 50 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -10 sq mm |
| 51 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-25 mm dia |
| 52 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- 40 mm dia |
| 53 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 54 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender