Public Administrative Department Government Departments Closing in 5 days TDR #58754144

Tender For Annual Plan-Dp Ekm - S0938/27 - Aluva District Hospital-Aluva District Hospital - Ht Renovation And Lt Electrical Distribution System Modernization -Electrical Works-Ht-Electrical-Work

Issued by Government Departments · Ernakulam, Kerala
Tender Value
99.44 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
5 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Plan-Dp Ekm - S0938/27 - Aluva District Hospital-Aluva District Hospital - Ht Renovation And Lt Electrical Distribution System Modernization -Electrical Works-Ht-Electrical-Work

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Nov-2026 Correction of License Other 04-Dec-2026

BOQ

Name of Work:- Annual Plan-DP EKM - S0938/27 - ALUVA DISTRICT HOSPITAL-Aluva District Hospital - HT Renovation and LT Electrical Distribution system Modernization -Electrical works-HT-Electrical-Work
Sl. No. Item Description
1SITC of 11 KV Multipanel and HT Renovation
2OD218449/2026-2027:Supply, coveyance , installation, testing and commissioning of Multi Panel - 11KV- VCBP-LBSP-LBSP- LBSP consisting Incomer : VCB Panel ( Intrans make 630A/26.30 KA/1S, Vaccum Circuit Breaker - 1 NO ) , Outgoing : LBS Panel - 3 nos with following accessories 11 Kv Indoor Resin Cast /5 A , 10VA class 0.20S CT - 3 Nos- 11 Kv Indoor Resin Cast /5 A 15 VA class 1 CT - 3 Nos , 15VA 5P10 protection CT - 3 nos- 11Kv/110V,25VA ,Cl: 0.2 Potential Transformer -1 No- 11Kv/110v, 100VA,Cl: 1 Potential Transformer - 1 No - IDMT relay 3o/c + 1 E/F - 1 No and Master trip Relay 1 no as protective devices - Digital Ammeter - 1 No- Digital voltmeter - 1 No - Indication lamps 5 Nos for VCB ONN - VCB OFF - Spring charge - trip circuit healthy - DC ON , 8 window Annunciation with Alarm - 1 No- Push button for trip circuit healthy - 1 NO , Aluminium Busbar- 50x10 mm , including Panel accessories VCB Panel - 1 no with Breaker control switch - 1 no - switch with plug point - 1 No- Strip heater - 1 No - Thermostat for space heater - 1 No - Cubicle lamp with switch - 1 No - Seal off Bshings - 1 set - Test terminal block -1 No including control Wiring , Load Break Switch with earth Switch - 3 Nos Panels - Each panel comprising with Aluminium Busbar connections , Support insulators , 3 Nos HT HRC Fuses , shunt trip coil 230V AC , Seal of Bushings - 1 set , ON/OFF Indication lamps -1 set etc. complete as per ISS , IEC standards. Make INTRANS or equivalent Make . .
3OD218448/2026-2027:Spply, conveyance , installation , testing and commissioning of Out door type 11 KV Metering Panel box consisting following : Panel - Metering Box - Outdoor 11 KV - 1 Set with 3 Nos CT Ratio /5 A , 10VA, Cl: 0.2 - 1 No Fixed type PT of ratio 11 KV/110 V, 25VA, Cl :0.2 - 1 No Seal Off Bushings - 1 No Space Heater with Thermostat - 1 No 400 A Aluminum busbars and support insulators - Provision for fixing TOD Meter etc. complete as per ISS , IEC standard and Departmental Specifications .
4OD218450/2026-2027:Supply , conveyance, testing and commissioning of Trivector Meter class 0.2s suitable for 110V (L-L ) 5A Lauritz Knudsen ( L&T) make Mode ER300P class 0.20s ( Base mounting ) Cat.No. WR300BB51RS suitable for 3Ph,4W TVM 110V (L-L) 5A Class 0.2s BM with RS485 Modbus including test report from the testing laboratory approved by the KSEB
5OD228040/2026-2027:Supply of 11 KV grade 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 2011 with latest amendments
68.3.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
7OD218593/2026-2027:Laying and clamping charges of 11 KV grade 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, using painted flat iron claps on existing cable tray/wall
810.1.4: Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials for following size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required:300 sq.mm
910.2.4:Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
1010.3.4:Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
1114.13.4:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required150 mm dia
127.9:Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
13OD228050/2026-2027:Supply and Fixing Mushroom type emergency Push button with 1 NC contact with suitable enclosure and giving connections.
14OD228051/2026-2027:Supply and providing 100/5A , 10VA , Accuracy class 10P 5 , Protection CT in suitable Painted MS box as Neutral CT of 250 KVA Indoor/ Out door type transformer
15OD228175/2026-2027:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 2.50 sq mm
16OD228176/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper control cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 2.50 sq mm with factory made clamp
1790.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
18OD228244/2026-2027:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.2 X 2.50/4sq. mm (16 mm)
19OD228202/2026-2027:Supply and fixing 60 mm long x 12 mm wide x 1 mm thick Copperearthing clips for 4 sq mm to 16 sq mm. single compression glands
202.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
21SITC of Main Switch Board ( MSB )
2290.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
2390.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
2490.14.2.3:Supply and providing 4mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
2590.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
2690.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
2790.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2890.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
2990.14.7:Supply and providing copper earth bus in the panel board
30OD218599/2026-2027:Supply and providing 800 A, 4 pole, electrical draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA Lauritz Knudsen Make Cat. No. SL96052 or equivalent make
31OD228367/2026-2027:Supply and providing 630 A, 4 pole, electrical draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA Lauritz Knudsen Make Cat. No. SL96051 or equivalent make
32OD218595/2026-2027:ACB Accessories : Supply and fixing Vertical Terminal Adaptors for Draw out type ACB up to 1200 A ACB Lauritz Knudsen Make Cat. No. SL 93281OOOO or equivalent make
33OD218596/2026-2027:ACB Accessories Supply and fixing shunt release for all voltage range up to 800A. Lauritz Knudsen Make Cat. No. SL927180BOO or equivalent make and giving connections.
34OD218597/2026-2027:ACB Accessories Supply and fixing under voltage release (UVR)for all voltage range up to 800A. Lauritz Knudsen Make Cat. No. SL927080BOOO or equivalent make and giving connections.
3590.14.10.16:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
3690.14.10.15:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
3790.14.10.9:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
3890.14.10.8:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
3990.14.10.7:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
4090.14.11.11:MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB.
4190.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
4290.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
4390.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
44OD218606/2026-2027:Supply and providing Multi function Meter VAF+PF meter with communication port Lauritz Knudsen Make 41XX series Cat. No. WL411011OOOO or equivalent make , Accuracy class 1 ,input voltage measurement range 50-520VAC (P-P ) , Auxiliary supply 80-300VAC/DC , CT secondary side selectable 1/5A , Flush mounting 96x96 mm , Parameters VLL,VLN,A,F,F,ON Hrs, RPM, Apeak
45OD218607/2026-2027:Supply and fixing Blue color LED Phase Indication lamp and giving connections
46OD218608/2026-2027:Supply and fixing Red , Yellow , black, Green and Orange color LED Phase Indication lamp and giving connections
47OD218609/2026-2027:Supply and fixing 400/5 A , 5VA, Accuracy class :1 Resin cast metering CT
48OD218610/2026-2027:Supply and fixing 800/5 A , 15VA, Accuracy Cl:1 Resin cast metering CT
49OD218611/2026-2027:Supply and fixing CT for 3P and 4P circuit Breakers for neutral overload and ground fault protection for 630 1600 A ACBs
50OD218612/2026-2027:Supply and Fixing 6A , 3 Pole Auto Manuel selector switch
51OD218613/2026-2027:Supply and providing Auxiliary Contact block 1 NO + 1 NC
52OD218614/2026-2027:Supply and Fixing Illuminated Push button switch Green color provide with Flush head Actuator and Auxiliary contact 1 NO + 1 NC
53OD218615/2026-2027:Supply , conveyance, testing and commissioning of Flush mounting type kWh Energy Meter Accuracy class 1 LED/LCD with RS485 communication port Lauritz Knudsen ( L&T) make Mode 4000 Series Cat. No. WL400011OOOO or equivalent suitable for Input voltage measurement range 50-520VAC (P-P) Aux supply 80-300VAC CT secondary site selectable 1/5A and size 96x96 mm etc. complete .
54OD228522/2026-2027:Supplying and fixing 0.5A to 4 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
55OD228525/2026-2027:Supply and fixing copper spreader terminal suitable for 630A MCCB ( Set of 3 )
56OD228523/2026-2027:Supply and fixing copper spreader terminal suitable for 315/400A MCCB ( Set of 3 )
57OD228524/2026-2027:Supply and fixing copper spreader terminal suitable for 200/250A MCCB ( Set of 3 )
58OD228526/2026-2027:Supply and fixing copper spreader terminal suitable for 160A MCCB ( Set of 3 )
59OD228527/2026-2027:Supply installation testing and commissioning of Single Pole Over current or Earth Fault relay Microcontroller based design , draw -out Enclosure , single phase OC/EF protection with site selectable 1A/5A CT rating ,Inverse and definite time delay , with communicable port Modubus RS 485 Port , suitable for Auxiliary supply 85-265 V AC , Model Lauritz Knudcen make OCR11 Cat. No. NROCR1B10RA or equivalent make and giving connections .
60OD233443/2026-2027:Supply and fixing single phasing preventer relay suitable for Auxiliary supply 230V AC L& T make model ST92166 OOOO or equivalent make and giving connections.
61OD228933/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.0 sq.mm copper control wiring .
62OD228934/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.50 sq.mm copper control wiring .
631.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
64OD218618/2026-2027:Supply, conveyance, installation, testing and commissioning of PLC ( Programmable Logic control ) system for All Incoming ACB and Bus Coupler ACB ( 1No.500KVA Transformer , 2 Nos 250 KVA Transformers, 1 no 500KVA DG set , 1 No. 250 KVA DG set and 2 Nos Bus Couplers ) including supply all components and interlocking system using control wires , programming etc. complete with following : Control Power supply (1) SMPS Make. DELTA - Model /Spec DRL-24V120W1EN, 24VDC, 5 Amps - 1 No. (2) MCB for SMPS Make : LK -2 Pole BB20160C -1No (3) Voltage protection relay Make LK model SM500 single phasing preventer + Selectable Under Voltage + Selectable Over Voltage - 5 Nos (4) Mobile through monitoring - VBOX Make: WECON model. V-BOX-H-G: Industrial lot Gateway with ethernet & RS 485 communication ,built-in - Wi-Fi & 4G ( Global ) module ,supports Modbus RTU/TCP ,Lua scripting , secure PLC - to Cloud- connectivity , remote monitoring and diagnostics - 1 No (5) Controllers PLC Make. DELTA model : DVP 125A211R : MPU with 8 DI ; 4DO (R) Main supply 24 V DC - 1 No. (6) Digital extension modules Make : DELTA model DVP165P11R , Digital ext. Module 8 DI ; 8 DO (R) Main supply 24V DC - 4 Nos (7) Digital extension Module Make: DELTA model ; DV908SM11N , Digital ext. Module 8 DI ; Main Supply 24V DC - 1 No (8) Control panel accessories Power indication lamps RYB - 3 Nos (9) Selector switch : 2 position AUTO/MANUEL - 1 No (10) Relay Card : 8 Channel , 1 Pole - 2 Nos ( 11) Relay with base : 4 Channel , 2 Pole - 2 no's ( 12) Emergency Push Button : Mushroom type - 1 No ( 13) Panel accessories with terminal blocks, control cables, Ferrules, ducts, lugs, DIN rails, 4 - Way rotary selector switch etc. - 2 sets (14) Service Panel assembly and testing including Panel fabrication, internal wiring , termination ,labelling and testing -3 sets (15) PLC Programming : Development of PLC Control logic , interlock , timers, and industrial network configuration. -2 sets (16) Installation, testing and Commissioning : Installation complete I/O checking , functional testing, and interlock verification , Integrated system testing and Final commissioning at site. -6 sets
65OD228492/2026-2027:Supply, installation, testing and commissioning of 2000 VA - 72V DC sinewave ZENRISE or equivalent make True Online UPS with inbuilt Isolation Transformer including 6 nos 6 EL 40Ah Exide make tubular battery, trolley type battery /inverter stand , connection copper lead wires and connections
662.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
67OD232737/2026-2027:Charges for Loading and unloading charges of Electrical Switch boards and Panels including all labor and hire charges of Tools and Plants.
68SITC of 65 KVAR Capacitor Panel
6990.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
7090.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
7190.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
7290.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
7390.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
7490.14.7:Supply and providing copper earth bus in the panel board
7590.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
7690.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
7790.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
7890.14.11.9:MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.
79OD229050/2026-2027:Supply and fixing copper spreader terminal suitable for 200/250A MCCB ( Set of 3 )
802.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
812.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
822.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
8390.14.24.55:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
8490.14.24.58:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
8590.14.24.60:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
8690.14.24.61:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
87OD218661/2026-2027:Supply and Fixing Panel mounting type 150x150 mm size Electrical enclosure Filter Panel mount vent on existing Panel
88OD218662/2026-2027:Supply and Fixing Panel mounting type 150x150 mm size AC ventilating cooling fan Legrand or equivalent make suitable for working 1 phase 240v , 50 Hz AC supply including Air vent cover etc. and giving connections.
89OD218663/2026-2027:Supply and Fixing 16A 2 Pole Power contactor with AC coil and 2 NO+2 NC Auxiliary contact
90OD218664/2026-2027:Supply and Fixing 16A 3 Pole capacitor duty Power contactor suitable for switching 10 / 5 KVAR capacitor banks with AC coil
91OD218665/2026-2027:Supply and Fixing 32A 3 Pole capacitor duty Power contactor suitable for switching 15 KVAR capacitor banks with AC coil
92OD218666/2026-2027:Supply and Fixing 63A 3 Pole capacitor duty Power contactor suitable for switching 20 KVAR capacitor banks with AC coil
93OD218667/2026-2027:Supply and Fixing 6A , 3 Pole Auto Manuel selector switch
94OD218668/2026-2027:Supply and providing Auxiliary Contact block 1 NO + 1 NC
95OD218669/2026-2027:Supply and Fixing Illuminated Push button switch Red color provide with Flush head Actuator and Auxiliary contact 1 NO + 1 NC
96OD218670/2026-2027:Supply and Fixing Illuminated Push button switch Green color provide with Flush head Actuator and Auxiliary contact 1 NO + 1 NC
97OD218671/2026-2027:Supply and fixing Blue color LED Phase Indication lamp and giving connections
98OD218740/2026-2027:Supply and fixing Red , Yellow , black, Green and Orange color LED Phase Indication lamp and giving connections
99OD218672/2026-2027:Supply and fixing 150/5 A , 5VA, Accuracy class :1 Resin cast metering CT
100OD218673/2026-2027:Supply and fixing 300/5 A , 5VA, Accuracy class :1 Resin cast metering CT
101OD218738/2026-2027:Supply and Fixing 8 stage APFC controller for Contactor switching with 1 CT APFC Panel Lauritz Knudsen Make etaSMART R Cat. No. CS90902OOOO with 96x96xmm size or equivalent make and giving connections .
102OD218739/2026-2027:Supply and providing Multi function Meter VAF+PF meter with communication port Lauritz Knudsen Make 41XX series Cat. No. WL411011OOOO or equivalent make , Accuracy class 1 ,input voltage measurement range 50-520VAC (P-P ) , Auxiliary supply 80-300VAC/DC , CT secondary side selectable 1/5A , Flush mounting 96x96 mm , Parameters VLL,VLN,A,F,F,ON Hrs, RPM, Apeak
103OD233132/2026-2027:Supply and fixing multifunction digital/numerical Analogue Timer to control time up to 24 Hrs with auxiliary supply 240V AC and giving connections
104OD229048/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.0 sq.mm copper control wiring .
105OD229049/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.50 sq.mm copper control wiring .
1061.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1071.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
10890.6.4.53:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run
10990.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
11090.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
11190.12.24.4:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm
11290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
11390.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
1142.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
115OD232738/2026-2027:Charges for Loading and unloading charges of Electrical Switch boards and Panels including all labor and hire charges of Tools and Plants.
116SITC of LT PANELS ( Sub Switch Boards )
11790.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
11890.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
11990.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
12090.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
12190.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
12290.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
12390.14.7:Supply and providing copper earth bus in the panel board
12490.14.10.16:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
12590.14.11.9:MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.
12690.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
12790.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
12890.14.11.3:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.
129OD229142/2026-2027:Supply and fixing copper spreader terminal suitable for 630A MCCB ( Set of 3 )
1302.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
1312.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
1322.1.6:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N
1332.1.7:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.320 Amp TP&N
134OD229141/2026-2027:Supplying and fixing 0.5A to 4 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
135OD229143/2026-2027:Supply and providing Multi function Meter VAF+PF meter with communication port Lauritz Knudsen Make 41XX series Cat. No. WL411011OOOO or equivalent make , Accuracy class 1 ,input voltage measurement range 50-520VAC (P-P ) , Auxiliary supply 80-300VAC/DC , CT secondary side selectable 1/5A , Flush mounting 96x96 mm , Parameters VLL,VLN,A,F,F,ON Hrs, RPM, Apeak
136OD229144/2026-2027:Supply and fixing Blue color LED Phase Indication lamp and giving connections
137OD229145/2026-2027:Supply and fixing Red , Yellow , black, Green and Orange color LED Phase Indication lamp and giving connections
138OD229146/2026-2027:Supply and fixing 150/5 A , 5VA, Accuracy class :1 Resin cast metering CT
139OD229147/2026-2027:Supply and fixing 400/5 A , 5VA, Accuracy class :1 Resin cast metering CT
140OD229139/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.0 sq.mm copper control wiring .
141OD229140/2026-2027:Supply and providing control wiring using ISI marked FRLS PVC insulated single core copper conductor cable through suitable size PVC Channel / trunking with copper lugs/ferrules , marking ferrules suitable ties etc. complete 1.50 sq.mm copper control wiring .
14290.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
14390.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1442.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
1452.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
1462.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
147OD232740/2026-2027:Charges for Loading and unloading charges of Electrical Switch boards and Panels including all labor and hire charges of Tools and Plants.
148SITC of LT Cables
14990.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
15090.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
15190.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
15290.12.5.43:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm
15390.12.5.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
15490.12.5.31:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mm
15590.12.5.33:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 150 sq mm
15690.12.5.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
15790.12.5.35:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
15890.12.5.37:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mm
15990.12.6.33:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 150 sq mm
16090.12.6.34:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm
16190.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
16290.12.6.37:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm
16390.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
16490.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
16590.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
16690.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
16790.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
16890.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
16990.12.7.37:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
17090.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
17190.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
17290.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
17390.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
17490.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
17590.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
17690.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
17790.12.10.5:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size
17890.12.10.7:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size
17990.12.10.9:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation145/123 mm or nearest size
1809.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
1819.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
1829.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
1839.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
1849.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
1859.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
1869.1.31:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
1879.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
1889.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
1899.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
1909.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
1919.2.24:Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm
1929.3.21:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 95 sq. mm
1939.3.24:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm
1949.3.22:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm
1959.3.26:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 240 sq. mm
1969.3.29:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
1979.3.30:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm
198OD233347/2026-2027:Supply and fixing , 60 mm long x 20 mm wide x 1.20 mm thickCopper earthing clips for 25 sq. mm to 95 sq. mm single compression glands
199OD233348/2026-2027:Supply and fixing 60 mm long x 12 mm wide x 1 mm thick Copperearthing clips for 4 sq mm to 16 sq mm. single compression glands
200OD233349/2026-2027:Supply and fixing 25x6 mm brass bolt, nut and washer
201SITC of ISI Earthing in Sub station , Sub switch boards & Gland Earthing etc.
202OD229707/2026-2027:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12mm thick ISI Plate earthing including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2035.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
20490.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
20590.16.3.12:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm copper strip
20690.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
20790.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
20890.16.3.6:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)40 x 6 mm GI strip
20990.16.3.7:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)50 x 6 mm GI strip
21090.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
21190.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
212OD233445/2026-2027:Supply and fixing 25x6 mm brass bolt, nut and washer
213OD233446/2026-2027:Supply and fixing 25x3 mm brass bolt, nut and washer
214Supply and Installation of Cable Tray
2154.6.8:Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts, etc as required.300 mm width x 62.5 mm depth x 2.0 mm thickness
2164.6.10:Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts, etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness
2174.6.11:Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts, etc as required.600 mm width x 62.5 mm depth x 2.0 mm thickness
2184.6.13:Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts, etc as required.900 mm width x 62.5 mm depth x 2.0 mm thickness
2194.7.8:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300mm width X62.5mm depth X 2.0 mm thickness
2204.7.10:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450mm width X62.5mm depth X 2 mm thickness
2214.7.11:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600mm width X62.5mm depth X 2 mm thickness
2224.7.13:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.900 mm width X62.5mm depth X 2 mm thickness
2234.10.10:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450mm width X 62.5 mm depth X 2 mm thickness
2244.10.11:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 600 mm width X 62.5mm depth X 2 mm thickness
2254.8.10:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450mm width X 62.5mm depth X 2 mm thickness
2264.8.11:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600mm width X 62.5mm depth X 2.0 mm thickness
2274.8.13:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.900mm width X 62.5mm depth X 2 mm thickness
228OD233141/2026-2027:Supplying and installation of following size of GI LADDER TYPE CABLE TRAY Height 50MM X Width 450MM X Thickness 1.50 mm ( Hot dip Galvanized ) using suitable Straight connector (Hot dip Galvanized ) every 3 mtr or as per the make of supplier using suitable wall/ceiling support etc. complete OBO or equivalent make.
22990.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
230Sub station General wiring
23190.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
23290.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
23390.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
23490.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
23590.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
23690.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture
23790.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
23890.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
23990.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
24090.4.10:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
241OD230466/2026-2027:Supply of 305 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C
24290.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
24390.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
2441.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
2451.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
2461.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
2471.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
2481.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2491.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2501.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2511.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2521.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
25390.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
25490.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
25590.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
25690.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
25790.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
25890.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
25990.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
26090.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2612.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
2622.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2632.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2642.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps
265OD233326/2026-2027:Supply, installation, testing and commissioning of 2000VA -24V DC ZENRISE or equivalent make Sinewave inverter with 2 nos 150Ah EXIDE 6ELtubular battery, trolley type battery rack/stand, connection copper lead wires and connections complete
266Civil & Miscellaneous Items
267OD233370/2026-2027:Supply and providing 2.5 mm thick , 11 kV , Synthetic elastomeric fire retardant insulating sheet / mat in position
268OD233371/2026-2027:Supply and providing 2.0 mm thick , 3.3 kV , Synthetic elastomeric fire retardant insulating mat in position
269OD233372/2026-2027:Supply and providing ABC type 5 Kg Fire Extinguisher with hose and wall clamp in position
270OD233373/2026-2027:Supply and providing 5 Kg Dry Chemical type Fire extinguisher with wall clamp
271OD233376/2026-2027:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
272OD233374/2026-2027:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height
273OD233375/2026-2027:Supply and providing First Aid Chart ( Shock Treatment Chart ) PVC laminated /duly framed and placed in a conspicuous location for clear vision.
27414.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
27514.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
27614.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
27714.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
27814.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
279Scheme Approval
280OD233392/2026-2027:Charges for Preparation of drawings including schematic circuit diagram for the existing HT / MV addition and necessary approval from the Electrical Inspectorate etc. All liaison works excluding Statutory Fee . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58754144
AUTHORITY Government Departments
TENDER VALUE 99.44 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Local Self Government Department
Work Description Tender for Annual Plan-Dp Ekm - S0938/27 - Aluva District Hospital-Aluva District Hospital - Ht Renovation And Lt Electrical Distribution System Modernization -Electrical Works-Ht-Electrical-Work
Basic Detail
Tender No ET162/DPEKM/AE/LSGD/26-27
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 27 Nov 2026
Submission Date 04 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 99.44 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
bbd0f305-7dd6-4cd4-bab3-479c906bde6d.html
BOQ_1529523.xls
RequisitionforEpaymentdocument.pdf
Tendernotice_1.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

bbd0f305-7dd6-4cd4-bab3-479c906bde6d.html

xls

BOQ_1529523.xls

pdf

RequisitionforEpaymentdocument.pdf

pdf

Tendernotice_1.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender