Tender For Dnit For Augmentation Of Water Supply Scheme Anial (Mh-Pc) Block Bamial Distt. Pathankot (Under Head:- 4215) Providing & Installing Of New Tubewell Of Size 200Mm I/D Straight Upto 115 Mtr Depth With Percussion Rig, Construction Of Pump Cha
Tender Overview
Project Description
Tender for Dnit For Augmentation Of Water Supply Scheme Anial (Mh-Pc) Block Bamial Distt. Pathankot (Under Head:- 4215) Providing & Installing Of New Tubewell Of Size 200Mm I/D Straight Upto 115 Mtr Depth With Percussion Rig, Construction Of Pump Chamber 3.05Mx3.70M With W.C, Providing And Installing Sub Set 7.40 Lps 48 Mtr Head, providing and Fixing Solar Panel Energy System, Construction Of Ohsr 75000 Ltr Capacity Having Staging Height 19 Mtr & Fsl 22 Mtr, providing and Fixing Ci Delivery, Providing And Installing Disinfection Unit, Upvc Rising Main 10Kg, Sluice Valve & Chamber, Development Of Water Works, Providing Laying Jointing Testing Of Upvc Pipe (Type-A) Including Excavation, Specials And Back Filling & providing & Fixing Of Sluice Valve & Haudi, Dismantling And Restoration Of Brick Paving, Concrete Road And Interlock Tile, providing and Fixing House Hold Connection & Bulk Meter Etc Complete In All Respect.
BOQ
| Sl. No. | Item Description |
| 1 | TUBEWELL |
| 2 | Drilling of telescopic bore 25\\" (625 mm) 22\\" (550 mm) 18\\" (450mm) 16\\" (400 mm) 14\\" (350mm) diameter with percussion rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site of the proposed bore (0 to 115mtr BGL) |
| 3 | 1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of water and water for drilling tubewell to be arranged by the firm/contractor at site at his own cost. |
| 4 | 2. In case the bore is converted into a tubewell payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore paid at the rate of beyond margin shall be paid at the rate of test bore drilling. |
| 5 | Supplying and lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS Code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 6 | 200mm nominal diameter (weight 33.6 Kg per meter) 6.40mm thickness |
| 7 | Supplying, fixing, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest with ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell bore. |
| 8 | 200mm internal diameter (slot size 0.75mm) 6.30 mm thickness (As per A & C Slip) |
| 9 | Supplying, fixing lowering of stainless steel socket as per IS: 8110-2000 or latest ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell Bore complete in all respects. |
| 10 | (200mm) i/d |
| 11 | Supplying and fixing of bail plug of MS pipe complete with inverted u-hock attached to the bottom plug complete in all respects (200mm) i/d weight 33.6 kg p/m) 6.40 mm Thick. |
| 12 | Supplying and Fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 13 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 200mm internal diameter |
| 14 | Supplying & fixing of M.S Clamp of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 15 | Supplying, lowering & fixing of M.S Special Socket to connect S.S. Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 200mm internal diameter |
| 16 | Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore. |
| 17 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 18 | Development and stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 19 | Capacity of Air compressor 300 cfm at 250 PSI |
| 20 | Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge |
| 21 | Collection of Water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 22 | Testing of water sample for heavy metal testing from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide and uranium etc) |
| 23 | Provision for Sanitary Clay seal (as per BIS Code IS 2800:2019) including sterilization of tubewell |
| 24 | PUMP CHAMBER |
| 25 | Construction of Pump Chamber size 3.05 m x 3.70m with gravel pit but including electric wiring as per DWSS standard design complete in all respects. Including provision for Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring ,PVC pipes , Junction Box , 1 No. Leach Pit , Super structure WC room etc. |
| 26 | PUMPING MACHINERY |
| 27 | Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of reputed make capable of delivering 7.4 LPS 48 mtr head along-with electric panel board consisting of electric appliance such as automatic Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, MVB/MCCBs etc. including 80mm G.I Column Pipe of suitable size 22 m (in 3 m Lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (of reputed make) complete in all respects. |
| 28 | Rate of Motor with Pump |
| 29 | Panel Board |
| 30 | Submersible cable Size 4.00mm2 |
| 31 | Column Pipe (G.I) 80 mm i/d |
| 32 | SOLAR PANEL ENERGY SYSTEM |
| 33 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. (PEDA Letter Number 7746 dated 19.12.25) |
| 34 | C.I.FITTING INSIDE PUMP CHAMBER |
| 35 | Providing & Installing 100 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch etc. inside the Pump chamber complete in all respects |
| 36 | Disinfection Unit: |
| 37 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. |
| 38 | RCC OHSR |
| 39 | Constructing of 1 No. RCC OHSR of 75KL (75000 ltr) Capacity having staging Height 19.00 mtr. & FSL 22.00 mtr from formation level complete with external RCC Stair case with landing slabs at each staging RCC roof, ventilator single manhole cover lightning conductor etc. complete as described in schedule No.3 providing and fixing CI/ DI K9 D/F expansion Joints, bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing Duck foot bends, Conforming IS-9523 with latest amendments) and DI/CI D/F sluice Valve duty ISI marked (IS 14846-2000 Or latest on each with inlet outlet and scour pipes. Including Providing and Installing inlet outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugally cast as per IS 8329-2000 with latest amendment duly ISI marked from bottom dome to duck foot Bond and further up to 2.75 mtr. As per detail specification TMT steel & painting of all complete shall he included in cost & P/F aluminum ladder inside/steel ladder outside tank of the OHSR including testing of soil bearing capacity tested from the reputated institute such as PEC Chandigarh / TTT Sector-26, Chandigarh GNEC/Ludhiana/Thapar Institute of Engineer and Technology Patiala Complete in all respect SBC shall be tested in the presence of Engineer or his representative as per specifications. (The specifications & drawing are based on safe bearing capacity of Soil is not less than 8.75 tons per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. The contractor shall summit his own design keeping in view seismic Zone-IV for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard, drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow houdi, including providing and fixing water Level indicating system and construction of plinth protection around OHSR with masonry toe wall with including foundation depth, earthing cc 1:8:16 with 40mm stone aggregate and conglomerate floor 40mm with CC 1:24 as per DWCC specification. Providing & applying, integral crystalling slurry of hydrophilic in nature for water proofing management for vertical and horizontal surface and swellable type water stop tape. |
| 40 | uPVC RISING MAIN |
| 41 | Providing, Laying , fixing & jointing of uPVC Pipes (Type-A) as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (10 Kgf./sqcm) . |
| 42 | 110mm o/d (Mechanical) |
| 43 | Sluice Valve & Sluice Valve Chambers |
| 44 | Providing & fixing C.I D/F Sluice Valves ISI marked 14846-2000, including cost of tail piece, rubber joint, gland dori, Nuts, bolts & accessories, complete in all respects. |
| 45 | 100 mm Nominal Bore (N.B.) |
| 46 | Construction of brick masonry sluice valve chamber size 0.90m x 0.90m complete in all respect |
| 47 | DEVELOPMENT OF WATER WORKS SITE. |
| 48 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects |
| 49 | Providing & Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4mm dia fencing pole size at bottom 4\\"x4\\", size top 3\\" x 4\\", Length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 50 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm complete in all respect |
| 51 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects |
| 52 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m complete in all respect. |
| 53 | Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works complete in all respect |
| 54 | Providing & fixing MS sign Board complete in all respect. |
| 55 | Providing, Laying , fixing & jointing of uPVC Pipes (Type-A) as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.(6Kgf./sqcm) |
| 56 | Excavation with JCB |
| 57 | uPVC Pipe 63 mm o/d |
| 58 | uPVC Pipe 75 mm o/d |
| 59 | uPVC Pipe 90 mm o/d |
| 60 | uPVC Pipe 110 mm o/d |
| 61 | uPVC Pipe 160 mm o/d |
| 62 | Excavation with Manually |
| 63 | uPVC Pipe 63 mm o/d |
| 64 | uPVC Pipe 75 mm o/d |
| 65 | uPVC Pipe 90 mm o/d |
| 66 | Providing, laying, jointing, fixing & testing of GI Pipe and specials Class-B including cost of material, complete in all respects including all taxes |
| 67 | GI Pipe 50mm i/d (For Pully Crossing) |
| 68 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. |
| 69 | DI Pipe 100 mm |
| 70 | Providing & fixing C.I D/F S.V. including cost of tail piece, rubber insertion, gland dori, Nut bolts & accessories complete in all respects. |
| 71 | 100mm i/d |
| 72 | 80mm i/d |
| 73 | Construction of masonry sluice valve chamber size 0.60m x 0.60m complete in all respect |
| 74 | Construction of masonry sluice valve chamber size 0.90m x 0.90m complete in all respect |
| 75 | Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj) |
| 76 | 90mm o/d |
| 77 | Dismantling and restoration of Cement Concrete and only Dismentling of Brick complete in all respect |
| 78 | 63mm o/d |
| 79 | Dismantling and restoration of Interlock Tile complete in all respect |
| 80 | 63mm o/d |
| 81 | 90mm o/d |
| 82 | Dismantling and restoration of Interlock Tile and only Dismentling of CC complete in all respect |
| 83 | 63mm o/d |
| 84 | Dismantling and restoration of Interlock Tile and only Dismentling of Brick complete in all respect |
| 85 | 63mm o/d |
| 86 | 75mm o/d |
| 87 | 90mm o/d |
| 88 | Making Connection with existing pipe line including cutting cost of D-Joint, labour for fixing specials excavation bailing out etc. |
| 89 | House water connection |
| 90 | Providing Proposed water connection to house hold up to wall with providing laying, jointing, testing MDPE pipe line 15mm o/d below ground level & GI 15mm i/d above ground level. Including cost of specials such as tees, bends, sockets, elbow etc, cutting threading and testing in trenches in the ground and ISI marked 15mm i/d GN ferrule as per IS:2692 and 3\\" i/d clamp with C.I bib cock 15mm i/d as per GM IS:210 with stainless steel spindle of approved make complete with excavation. |
| 91 | Water connection on Proposed line |
| 92 | Water Connection on Replaced pipe line (shifted) |
| 93 | Bulk MeterProviding & Installing of Bulk Meter inside water works including rubber jain, Nut Bolts, Cutting and threading, piece for fixing Bulk Meter including carriage complete in all respects (ISI Make) Size 100 mm i/d |
| 94 | Environmental Management Charges |
| 95 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 96 | Digging of pits in all kinds of soil &refilling the same , with the excavated earth mixed with well decayed farm yard manure @30% of pit volume and insecticide for termite control. |
| 97 | Supplying and planting permanent trees in prepared pits and watering |
| 98 | Planting seasonal flower in bedsPlanting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row |
| 99 | Painting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row |
| 100 | Providing for one way stand post with Khura complete in all respects. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender